ML17331A700

From kanterella
Revision as of 09:46, 4 June 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
LER 81-007/03L-0:on 810315 During Operation of 2CD Emergency Diesel in Preparation for Surveillance,Hot Starting Air Line Observed.Caused by Valve Damage & Exhaust Expansion Joint Inner Liner Failure.Intake & Exhaust Valves Replaced
ML17331A700
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 04/14/1981
From: WIZNER D G
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML17326A873 List:
References
LER-81-007-03L-01, LER-81-7-3L-1, NUDOCS 8104210363
Download: ML17331A700 (2)


Text

NRCFORIVL366l7.77)I~~V.S.NUCI.EARREGULATORYCOMMISSIONLlCENSEEEVENTREPORTCONTROLBLOCK:(PLEASEPRINTORTYPEALLREQUIREDINFORMATION)I6NI0CC2QE000000000Q341111QE~QE89LICENSEE'ODE1415LICENSENUMBER2626LICENSETYPE3057CAT58CON'T0IsoURcELJO050003167031581QOBDOCKETNUMBER6869EVENTDATE74/5REPORTDATE80EVENTDESCRIPTIONANDPROBABLECONSEQUENCESQ10~02DURINGOPERATIONOF2CDEMERGENCYDIESELINPREPARATIONFOR18MONTHSURVfILLANCE,A~03~04~OS~osHOTSTARTINGAIRLINEWASOBSERVED.THEfNGINEWASREMOVEDFROMSERVICEANDDECLAREDINOPfRABLEPERT.S.3.8.1.1THEACTIONREQUIREMENTSWfREMET.THEUNITWASBEINGCOOLEDDOWNFORASCHEDULEDREFUELINGOUTAGE.THE2ABDIESELREMAINEDOPERABLE.PUB-LICHEALTHANDSAFETYWASNOTAFFECTEDBYTHISEVENT.ASIMILAROCCURfNCEWASREPORTED~07ASRO78-~OB789~Os03L-O.8078SYSTEMCAUSECAUSECOMP.VALVECODECODESUBCODECOMPONENTCODESUBCODESUBCODE~EEQLIL~JQLJQI3VALVEXQELBGE~Go910111213181920SEOUENTIALOCCURRENCEREPORTREVISIONLER/ROEVENTYEARREPORTNO.CODETYPENO.QI7REPORT~01~~007~m~032122232426272829303132ACTIONFUTUREEFFECTSHUTDOWNATTACHMENTNPRDQPRIMECOMP.*COMPONENTTAKENACTIONONPLANTMETHODHOURSQ22SUBMITTEDFORMSUB.SUPPLIERMANUFACTURER~CQIB~XQ19~ZQ20~ZQ210000~YQ23~YQ24~AQ25W315Q2B3334353637404142434447CAUSEDESCRIPTIONANDCORRECTIVEACTIONQ27TTARTGAIRVALVEFOR4REARBANKCYLINDERWORTHINGTONPARTNO.56000001,STUCKOPENEXPOSINGTHESTEMTOFLUCTUATINGHIGHPRESSUREANDTEMPERATUREOUETOCOMBUSTION.INTHECYLINDERANDRESULTINGINFATIGUEFAILURE.ALLCYLINDERHEADSWEREREMOVED3ANDTHECYLINDERSINSPECTED.METALPIECESWEREREMOVEDFROM¹2AND¹4REARBANKCYL-4INDERS.¹2REARBANKPISTONCYLINDERHEADANDSLEEVfWEREREPLACED.(CONTINUED)80NA80808080NRCUSEONLYo80~o0PHONE789FACILITY~3PMETHODOFSTATUS%POWEROTHERSTATUSQDISCOVERYDISCOVERYDESCRIPTIONQ32~ls~OQ23~000QssN/A~AQSIOPERATOROBSERVATION789101213444546ACTIVITYCONTENTRELEASEDOFRELEASEAMOUNTOFACTIVITYQ3SLOCATIONOFRELEASEQEKLZJQ3IZlQ-78910114445PERSONNELEXPOSURESNUMBERTYPEDESCRIPTIONQ39~l7~000Q37~ZQSsNA789111213PER50NNELINJURIESNUMBERDESCRIPTIONQ41EK~~OQ4oNA7891112LOSSOFORDAMAGETOFACILITYQ43TYPEDESCRIPTION9~ZQ42NA8910PUBLICITYIssUEDUEEERIPTIUN~o8106PNX(/3'~NQ44N/A789106869NAMEOFPREPARERDAVIDG.WZ SUPPLEMENTTOLER¹81-007/03L-0SUPPLEMENTTOCAUSEDESCRIPTION:THEINTAKEANDEXHAUSTVALVESIN¹4REARBANKCYLINDERHEADWEREREPLACED.ALLSTARTINGAIRVALVESWEREINSPECTED.TWOADDITIONALSTARTINGAIRVALVESWEREFOUNDSTUCKOPEN.THf¹4REARBANK,¹2FRONTBANKAND¹5REARBANKSTARTINGAIRVALVESWEREREPLACED.THEREARBANKSTARTINGAIRDISTRIBUTORWASREPLACED.INSPECTIONOFSTARTINGAIRVALVESWILLBEAPARTOFTHE18MONTHSURVEILLANCEINBOTHUNITS.INSPECTIONOFTHETURBOCHARGERREVEALfDTHATITWASDAMAGEDBYSMALLPARTSOFTHEFAILfDSTARTINGAIRVALVfANDFAILUREOFTHEEXHAUSTEXPANSIONJOINTINNfRLINERS.THETURBOCHARGERROTORWASREPLACED.ALLOFTHELINERSHAVEBEENRfMOVEDFROM2CDDIESEL.LINERSONTHETHREEREMAININGDIESELENGINESWILLBEREMOVfDDURING'UBSEQUENT18MONTHSURVEILLANCEINSPECTIONS.