Letter Sequence Supplement |
---|
|
|
MONTHYEARML16355A3462016-12-14014 December 2016 Proposed Alternative to ASME Section XI Requirements for Repair/Replacement of Circulating and Service Water Class 3 Buried Piping in Accordance with 10 CFR 50.55a(Z)(1) Project stage: Request ML17033A2832017-02-0606 February 2017 Supplemental Information Needed for Acceptance of Requested Licensing Action Proposed Alternative to ASME Section XI Requirements in Accordance with 10CFR 50.55a(z)(1) Project stage: Acceptance Review ML17031A1302017-02-23023 February 2017 Request for Withholding Information from Public Disclosure Project stage: Withholding Request Acceptance ML17055C3602017-02-23023 February 2017 Submittal of Supplement to Proposed Alternative to ASME Section XI, Requirements for Repair/Replacement of Buried Circulating and Service Water Class 3 Piping with Carbon Fiber Reinforced Polymer Project stage: Supplement ML17030A0812017-02-24024 February 2017 Request for Withholding Information from Public Disclosure Project stage: Withholding Request Acceptance ML17251A9002017-06-0505 June 2017 Enclosure 2, Attachment E to 17-296, WEKO-SEAL - Recommended Installation Procedures for Water and Waste-Water Piping, Miller Pipeline, Revised 03/05/17 Project stage: Request ML17156A0832017-07-0303 July 2017 Non-Prop RAI - Regarding Proposed Alternative to ASME Section XI Requirements for Repair/Replacement of Circulating and Service Water Class 3 Buried Piping in Accordance with 10 CFR 50.55a(z)(1) (CAC Nos. MF8987-88) Project stage: RAI ML17251A8952017-08-31031 August 2017 Proposed Alternative to ASME Section XI Requirements for Repair/Replacement of Buried Circulating and Service Water Class 3 Piping with Carbon Fiber Reinforced Polymer Response to Request for Additional Information Project stage: Response to RAI ML17264A2272017-10-20020 October 2017 Request for Withholding Information from Public Disclosure Project stage: Withholding Request Acceptance ML17277A2962017-11-0202 November 2017 Request for Withholding Information from Public Disclosure (CAC Nos. MF8987 and MF8988; EPID L-2016-LLR-0019) Project stage: Withholding Request Acceptance ML17303A0682017-12-20020 December 2017 Nonproprietary Relief from the Requirements of the ASME Code (CAC Nos. MF8987 and MF8988; EPID L-2016-LLR-0019) Project stage: Approval ML18068A0642018-03-26026 March 2018 Relief from the Requirements of the ASME Code Repair/Replacement of Buried Circulating and Service Water Class 3 Piping with Carbon Fiber Reinforced Polymer (CAC Nos. MF8987 and MF8988; EPID L-2016-LLR-0019) Project stage: Approval 2017-02-24
[Table View] |
Similar Documents at Surry |
---|
Category:Legal-Affidavit
MONTHYEARML24130A2492024-05-0909 May 2024 Submittal of Information in Support of Surry Power Station Unit 1 Thermal Shield Flexure Replacement Campaign ML24051A1782024-02-19019 February 2024 Proposed License Amendment Request - Application to Revise Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam Generator Tube Inspections ML23096A2982023-04-0606 April 2023 Units 1 and 2 and Millstone Power Station, Units 2 and 3 - Request for Approval of Appendix F of Fleet Report DOM-NAF-2-P Qualification of the Framatome ORFEO-GAIA and ORFEO-NMGRID CHF Correlations in the Dominion ML22353A6202022-12-19019 December 2022 Request for Approval of Appendix F Fleet Report DOM-NAF-2-P, Qualification of the Framatome ORFEO-GAIA and ORFEO-NMGRID CHF Correlations in the Dominion Energy VIPRE-D Computer Code ML22322A1822022-11-18018 November 2022 Proposed Emergency Plan Revision - Relocation of the Technical Support Center ML21294A3382021-10-21021 October 2021 Proposed Amendment to Relocate Unit Staff Qualification Requirements from Technical Specifications to Nuclear Facility Quality . ML21259A0852021-09-15015 September 2021 North Ann, and Surry, Units 1 and 2, Millstone, Units 2 and 3, Request for Approval of Appendix E of Fleet Report DOM-NAF-2-A Qualification of the Framatome BWU-I CHF Correlation in the Vipre-D Computer Code Response to Request for Addition ML21133A2852021-05-13013 May 2021 Stations, Units 1 & 2 and Millstone Power Station, Units 2 and 3 - Request for Approval of Appendix E Fleet Report DOM-NAF-2-A Qualification of the Framatome Bwui CHF Correlation in the Dominion Energy VIPRE-D Computer Code ML21084A2732021-03-24024 March 2021 License Amendment Request - Application of Leak-Before-Break Methodology to Reactor Coolant System Branch Piping - Response to Request for Additional Information and Clarification ML21042B3212021-02-11011 February 2021 Stations, Units 1 & 2; Millstone Power Station, Units 2 & 3 - Request for Approval of Fleet Report DOM-NAF-2 Qualification of the Framatome BWU-I CHF Correlation in the Dominion Energy VIPRE-D Computer Code ML20296A6232020-10-22022 October 2020 Request for NRC Approval to Apply Leak-Before-Break Methodology to Reactor Coolant System Branch Piping ML20149K6942020-05-28028 May 2020 Response to Request for Additional Information, to Proposed License Amendment Requests Addition of Analytical Methodology to the Core Operating Limits Report for a Small Break Loss of Coolant Accident ML19343A0192019-12-0606 December 2019 Application to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors ML19267A0422019-09-16016 September 2019 Subsequent License Renewal Application Response to NRC Requests for Confirmation of Information Set 2 ML19253B3302019-09-0303 September 2019 Response to Requests for Additional Information - Sets 3 and 4 - Subsequent License Renewal Application ML19204A3572019-07-17017 July 2019 Subsequent License Renewal Application Response to Request for Additional Information - Set 2 ML19196A1092019-07-0909 July 2019 Stations, Units 1 and 2 - Proposed License Amendment Requests Re Addition of Analytical Methodology to the Core Operating Limits Report for a Small Break Loss of Coolant Accident (SBLOCA) Response to Request for Additional. ML19183A3862019-06-27027 June 2019 Subsequent License Renewal Application - Response to Requests for Additional Information - Set 1 ML19095A5972019-04-0202 April 2019 Submittal of Supplement to Subsequent License Renewal Application Change Notice 2 ML18291A8352018-10-15015 October 2018 Submittal of Application for Subsequent Renewed Operating Licenses ML18218A1702018-07-31031 July 2018 Proposed License Amendment Request Revision of Analytical Methodology Reference in Core Operating Limits Report for Small Break Loss of Coolant Accident ML17251A8972017-08-24024 August 2017 Enclosure 3 to 17-296, Affidavit from Structural Group ML17251A8982017-08-16016 August 2017 Affidavit from Simpson Gumpertz & Heger, Inc ML17055C3602017-02-23023 February 2017 Submittal of Supplement to Proposed Alternative to ASME Section XI, Requirements for Repair/Replacement of Buried Circulating and Service Water Class 3 Piping with Carbon Fiber Reinforced Polymer ML15324A0442015-11-12012 November 2015 Request for Withholding Proprietary Information from Public Disclosure ML0501903172004-12-17017 December 2004 Virginia Electric and Power Company Surry Power Station Units 1 and 2 - Proposed Technical Specifications Change Request for Reactor Coolant System Pressure/Temperature Limits. Ltops Setpoint, and Ltops Enable Temperature with Exemption. ML19093B5491980-09-18018 September 1980 Motion for a Stay Pending Appeal ML19093B3211979-04-0202 April 1979 Licensee'S Answer to Show Cause Orders ML19093B0171978-04-27027 April 1978 Attached Herewith Are 40 Copies of Additional Information Concerning the Steam Generator Replacement at the Surry Power Station ML19093B0321977-12-0202 December 1977 Provide Additional Information Concerning Steam Generator Replacement, Submitting as Revision 1 to Steam Generator Program, Surry Power Station, Unit Nos. 1 & 2. ML19093B0121977-08-17017 August 1977 Attached Herewith Certain Information Which Identified & Marked as Proprietary, Being Submitted in Conjunction with Document Entitled Steam Generator Program, Surry Power Station, Unit Nos. 1 & 2. ML19098B4491977-07-0505 July 1977 Response to Letter of 5/20/1977, Furnishing Information Re Postulated Fuel Handling Accident in Containment & Submitting Revised Analysis Including Proposed Tech Spec ML19094B4611975-07-23023 July 1975 Request for Amendment to Operating Licenses, Technical Specification Change No. 32. Changes Update Organizational Chart & Maximize Effectiveness of System Nuclear Safety & Operating Committee ML19093B3341975-07-17017 July 1975 Request for Amendment to Operating Licenses DPR-32 & DPR-37 for Technical Specification Change No. 31 2024-05-09
[Table view] Category:Letter
MONTHYEARML24283A0702024-10-0707 October 2024 Annual Submittal of Technical Specifications Bases Changes Pursuant to Technical Specification 6.4.J IR 05000280/20244032024-10-0303 October 2024 Cyber Security Inspection Report 05000280-2024403 and 05000281-2024403 Cover Letter (Public) IR 05000280/20240102024-10-0202 October 2024 Biennial Problem Identification and Resolution Inspection Report 05000280/2024010 and 05000281/2024010 ML24270A0022024-09-25025 September 2024 Inservice Inspection Owners Activity Report (OAR) ML24248A1712024-09-0303 September 2024 Proposed License Amendment Request - Temporary Service Water Supply to the Component Cooling Heat Exchangers IR 05000280/20240052024-08-26026 August 2024 Updated Inspection Plan for Surry Power Station, Units 1 and 2 (Report 05000280/2024005 and 05000281-2024005), Rev 1 ML24219A2372024-08-23023 August 2024 Issuance of Amendment Nos. 319 and 319, Adoption of TSTF-577, Rev. 1, Revised Frequencies for Steam Generator Tube Inspection, ML24207A0402024-08-21021 August 2024 Summary of July 17, 2024, Public Meeting - TS 3.7/3.14 AOT for SW Piping Maintenance IR 05000280/20240112024-08-13013 August 2024 Comprehensive Engineering Team Inspection Report 05000280/2024011 and 05000281/2024011 ML24164A0012024-08-12012 August 2024 Proposed Alternative Relief Request V-1 Inservice Testing of Pressure Isolation Valves (EPID l-2023-LLR-0060) IR 05000280/20240022024-08-0101 August 2024 Integrated Inspection Report 05000280/2024002 and 05000281/2024002 05000280/LER-2024-001, Troubleshooting Initiated Unknown Turbine Trip Feature in Control System2024-07-30030 July 2024 Troubleshooting Initiated Unknown Turbine Trip Feature in Control System ML24165A2782024-07-17017 July 2024 Issuance of Amendment Nos. 318 and 318, Reclassification of Regulatory Guide 1.97 Variable for Low Head Safety Injection ML24165A1232024-07-17017 July 2024 Proposed Alternative Relief Request P-1, P-2 Inservice Testing of Residual Heat and Containment Spray Pumps (EPID l-2023-LLR-0058) ML24190A4192024-07-0808 July 2024 Inservice Testing (IST) Program for Pumps and Valves Revised Sixth IST Interval Start Date and Updated Technical Specifications References for Alternative Request V-1 ML24179A2932024-07-0101 July 2024 Notification of Inspection and Request for Information for NRC Problem Identification and Resolution Inspection ML24178A2422024-06-25025 June 2024 2023 Annual Report of Emergency Core Cooling System (ECCS) Model, Changes Pursuant to the Requirements of 10 CFR 50.46 ML24177A2792024-06-20020 June 2024 Preparation and Scheduling of Operator Licensing Examinations ML24166A0622024-06-18018 June 2024 – Proposed Alternative Relief Request P-3, P-4 Inservice Testing of Boric Acid, Component Cooling Water Pumps ML24157A0542024-06-13013 June 2024 Audit Summary in Support of License Amendment Request for Proposed Reclassification of Low Head Safety Injection Flow Instrumentation Related to Regulatory Guide 1.97 ML24143A1622024-06-12012 June 2024 – Correction to Issuance of Amendment Nos. 297 and 280 and Surry Units 1 and 2, Correction to Issuance of Amendment Nos. 317 and 317, to Change Emergency Plan Staff Augmentation Times ML24170B0532024-06-10010 June 2024 DOM-NAF-2-P/NP-A, Revision 0.5, Reactor Core Thermal-Hydraulics Using the VIPRE-D Computer Code ML24141A2512024-05-20020 May 2024 Proposed License Amendment Request - Reclassification of Low Head Safety Injection Flow Indication Regulatory Guide 1.97 Variable - Supplemental Information ML24141A0482024-05-17017 May 2024 EN 56958_1 Ametek Solidstate Controls, Inc ML24136A2302024-05-13013 May 2024 Core 1 Cycle 33 Pattern Mdr Revision 0 ML24130A2492024-05-0909 May 2024 Submittal of Information in Support of Surry Power Station Unit 1 Thermal Shield Flexure Replacement Campaign ML24130A2032024-05-0909 May 2024 Proposed License Amendment Request Application to Revise Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam Generator Tube Inspections Supplemental Information ML24130A1192024-05-0707 May 2024 Inservice Test Program for Pumps and Valves Sixth Interval Update and Associated Relief and Alternative Requests - Response to Request for Additional Information Regarding Alternative Request V-1 ML24142A3852024-04-30030 April 2024 2023 Annual Radioactive Effluent Release Report IR 05000280/20240012024-04-30030 April 2024 Integrated Inspection Report 05000280-2024001 and 05000281-2024001 ML24122C6522024-04-30030 April 2024 Annual Radiological Environmental Operating Report ML24122B3032024-04-29029 April 2024 Associated Independent Spent Fuel Storage Installation, Revision to Emergency Plan Report of Change IR 05000280/20244022024-04-29029 April 2024 Security Baseline Inspection Report 05000280/2024402 and 05000281/2024402 ML24115A1952024-04-24024 April 2024 Notification of Surry Power Station Comprehensive Engineering Team Inspection - U.S. NRC Inspection Report 05000280/2024011 and 05000281/2024011 ML24054A0142024-04-22022 April 2024 Issuance of Amendment Nos. 297 and 280, and Surry Power Station Unit Nos. 1 and 2, Issuance of Amendment Nos. 317 and 317, to Change Emergency Plan Staff Augmentation Times ML24108A1812024-04-15015 April 2024 Proposed License Amendment Request - Reclassification of Low Head Safety Injection Flow Indication Regulatory Guide 1.97 Variable Supplemental Information ML24095A2172024-04-12012 April 2024 – Review of the Spring 2023 Steam Generator Tube Inspection Report ML24088A2482024-03-26026 March 2024 Inservice Testing Program for Pumps and Valves Sixth Interval Update and Associated Relief and Alternative Requests- Response to Request for Additional Information ML24087A2082024-03-22022 March 2024 Proposed License Amendment Request Addition of Containment Limiting Condition for Operation and Surveillance Requirements ML24078A2642024-03-21021 March 2024 – Regulatory Audit in Support of License Amendment Request to Proposed Reclassification of Regulatory Guide 1.97 Variable for Low Head Safety Injection Flow Instrumentation ML24087A1522024-03-18018 March 2024 Annual Changes, Tests, and Experiments Report Regulatory Commitment Evaluation Report ML24023A5762024-03-0808 March 2024 Correction to Issuance of Amendment Nos. 315 and 315, Regarding Revised Emergency Plan for Relocation of the Technical Support Center IR 05000280/20230062024-02-28028 February 2024 Annual Assessment Letter for Surry Power Station, Units 1 and 2 - NRC Inspection Reports 05000280/2023006 and 05000281/2023006 ML24032A4712024-02-20020 February 2024 Exemption from Select Requirements of 10 CFR Part 73 - Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting ML24051A1782024-02-19019 February 2024 Proposed License Amendment Request - Application to Revise Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam Generator Tube Inspections ML24057A0612024-02-19019 February 2024 and Virgil C. Summer Power Nuclear Stations - Nuclear Property Insurance Coverage IR 05000280/20230042024-02-0909 February 2024 Integrated Inspection Report 05000280/2023004 and 05000281/2023004 IR 05000280/20244012024-02-0606 February 2024 Security Baseline Inspection Report 05000280/2024401, 05000281/2024401 and 07200002/2024401 IR 05000280/20230102024-01-18018 January 2024 – Age Related Degradation Inspection Report 05000280-2023010 and 05000281-2023010 ML23312A1922024-01-18018 January 2024 Issuance of Amendment Nos. 316 & 316 Regarding a Risk Informed Approach for Tornado Classification of the Fuel Handling Trolley Support Structure 2024-09-03
[Table view] |
Text
PROPRIETARY INFORMATION-WITHHOLD UNDER 10 CFR 2.390 VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 February 23, 2017 10 CFR 50.55a United States Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555 Serial No.: NRNGDM: Docket Nos.: License Nos.: VIRGINIA ELECTRIC AND POWER COMPANY (DOMINION) SURRY POWER STATION UNITS 1AND2 17-060 R1 50-280/281 DPR-32/37 SUPPLEMENT TO PROPOSED ALTERNATIVE TO ASME SECTION XI REQUIREMENTS FOR REPAIR/REPLACEMENT OF BURIED CIRCULATING AND SERVICE WATER CLASS 3 PIPING WITH CARBON FIBER REINFORCED POLYMER By letter dated December 14, 2016 (Serial No.16-448), Dominion submitted a proposed inservice inspection (ISi) alternative request in accordance with 10 CFR 50.55a(z)(1) to allow the use of a Carbon Fiber Reinforced Polymer (CFRP) system for the internal repair of buried Circulating Water (CW) and Service Water (SW) systems' piping at Surry Power Station (Surry) Units 1 and 2. By letter dated February 6, 2017, the NRC provided Dominion an opportunity to supplement the proposed alternative request identified above by providing: 1) specific analyses or technical evaluations demonstrating the structural integrity of the separate CFRP pipe repairs, and 2) the justification and rationale for the use of the Load and Resistance Factor Design methodology for safety related ASME Class 3 piping, and a discussion of the analysis method used in the original design for Class 3 CW and SW piping, and any variances from applying both methods. Dominion's response to the NRC's request for supplemental information is provided in Attachment 1. The supplemental technical information provided in Attachment 1 for the proposed alternative request was prepared by Simpson Gumpertz & Heger, Inc., and contains information proprietary to that company. Therefore, this information is supported by an affidavit, signed by Simpson Gumpertz-& Heger, Inc., the owner of the information. The affidavit sets forth the bases on_ which the information may be withheld from public disclosure by the Commission and addresses with specificity the considerations listed in paragraph (b)(4) of 10 CFR 2.390 of the Commission's regulations. Accordingly, it is respectfully requested that the information, which is proprietary to Simpson Gumpertz & Heger, Inc., be withheld from public disclosure in accordance with 10 CFR 2.390 of the Commission's regulations. The affidavit is included in the Simpson Gumpertz & Heger, Inc. letter to the NRC entitled, "Withholding of Certain Proprietary Information Pursuant to 10 CFR 2.390," dated February 17, 2017. The Simpson Gumpertz & Heger, Inc. authorization letter is provided in Attachment 2. In conformance with the requirements ATTACHMENT 1 CONTAINS PROPRIETARY INFORMATION THAT IS BEING WITHHELD FROM PUBLIC DISCLOSURE UNDER 10 CFR 2.390. UPON SEPARATION OF ATTACHMENT 1, THIS LETTER IS DECONTROLLED. .
Serial No.17-060 Docket Nos. 50-280/281 Supplemental Response CFRP Alternative Request Page 2 of 3 of 10 CFR 2.390 concerning the protection of proprietary information, the proprietary information included in Attachment 1 is considered to be proprietary in its entirety and has been marked in the manner authorized by 10 CFR 2.390(b)(1)(i)(A). One editorial correction is also noted in Dominion's December 14, 2016 submittal. Specifically, the submittal cover letter stated the date of the Structural Group, Inc., letter to the NRC entitled, "Application for Withholding Proprietary Information from Public Disclosure," which was included in Enclosure 10 of that letter, was dated November 23, 2015. The correct date is November 23, 2016. If you have any questions or require additional information, please contact Mr. Gary D. Miller at (804) 273-2771. Sincerely, Mark Sartain Vice President -Nuclear Engineering and Fleet Support Commitments contained in this correspondence: None Attachments 1. Supplemental Response, Alternative Request to Use Carbon Fiber Reinforced Polymer System for the Internal Repair of Buried Circulating and Service Water Piping [PROPRIETARY] 2. Application for Withholding Proprietary Information from Public Disclosure cc: U.S. Nuclear Regulatory Commission -Region II Marquis One Tower 245 Peachtree Center Ave., NE Suite 1200 Atlanta, Georgia 30303-1257 NRC Senior Resident Inspector Surry Power Station Ms. K. R. Cotton Gross NRC Project Manager-Surry U. S. Nuclear Regulatory Commission One White Flint North Mail Stop 0-8 G9A 11555 Rockville Pike Rockville, Maryland 20852 Ms. B. L. Mozafari NRC Project Manager-North Anna U. S. Nuclear Regulatory Commission One White Flint North Mail Stop 0-8 H12 11555 Rockville Pike Rockville, Maryland 20852 Serial No.17-060 Docket Nos. 50-280/281 Supplemental Response CFRP Alternative Request Page 3 of 3 Serial No.17-060 Docket Nos. 50-280/281 Supplemental Response CFRP Alternative Request APPLICATION FOR WITHHOLDING PROPRIETARY INFORMATION *FROM PUBLIC DISCLOSURE Virginia Electric and Power Company (Dominion) Surry Power Station Units 1 and 2 I I 17 February 2017 U.S. Nuclear Regulatory Commission Document Control Desk 11555 Rockville Pike Rockville, MD 20852 SIMPSON GUMPERTZ &. HEGER I Engineering of Slruclures and Building foclosures
Subject:
Withholding of Certain Proprietary Information Pursuant to 10 CFR 2.390 .
Reference:
(1) Supplemental Response to Letter from Virginia Electric; and Power Company to US NRC, "Proposed Alternative to ASME Section XI Requirements for Repair/Replacement of Circulating and service Water Class 3 Buried Piping in Accordance with 10 CFR 50.55a(z)(1 ),'; Docket Nos. 50-280 and 50-281, Serial No.16-448. . Document No.: 161295-SGH-L-002 In Reference (1), Virginia Electric and Power Company (VEP) will provide a submittal to the U:S. Nuclear Regulatory Commission (NRG) that contains certain proprietary information owned by Simpson Gumpertz & Heger Inc. (SGH). SGH provided the information to VEP or a VEP affiliate to support the request made iri Reference (1 ); and VEP is authorized to use this information. .As explained in the attached affidavit, SGH'.s proprietary information contained in Reference (1) qualifies for withholding* under the exemption from disclosure set forth in the Freedom of Information Act ("FOIA"), 5 U.S.C. Section 552(b)(4), the Trade Secrets Act,* 18 U.S.G. Section 1905, an.d NRG regulations 10 GFR 9.17(a)(4) and 2 .. 390(a)(4) for trade secrets and commercial information. SGH respectfully requests that the NRC withhold this information from public disclosure. An affidavit supporting this request is attached. Please contact me by phone at 781.907 .. 9231 or email at RPOjdrovic@sgh.com if you have any questions concerning this request.. Kind regards, Rasko P. Ojdrovic Vice President and Senior Principal Simpson Gumpertz & Heger Inc.
Attachment:
1 o CFR 2.390 Affidavit SIMPSON GUMPERTZ & HEGER INC. Seyon Stmel. Building. l. Suite 500. Waltham. MA 02453 main: 181.907.9000 10.: 781.907.9009 www.5gh.com Boslon I I Haus.ton I New York I Son Francisco I California I Woshington. DC 10 CFR: 2.390 Affidavit \\\DC. OJSl2()/000001. JIS2313 vi SIMPSON GUMPERTZ & HEGERINC. 10 CFR 2.390 AFFIDAVIT OF RASKO P. OJDROVIC AFFIDAVIT I, Rasko P. Ojdrovic, hereby state as follows: {l) I am the Vice President and Senior Principal of Simpson Gumpertz & Heger Inc. {SGH), and I have been authorized to execute this affidavit on behalf of SGH. (2) Virginia Electric and Power Company will submit a transmittal to the US NRC entitled "Supplement to Proposed Alternative to ASME Section XI Requirements for Repair/Replacement of Buried Chculatingand Service Water Class 3 Piping with Carbon Fiber Reinforced Polymer" Docket Nos. and 50-281, Serial No.17-060. Certain portions of that transmittal contain proprietary information owned by SGH. This information should be held in confidence by the NRC arid withheld from public disclosure. The following is a list of the SOH proprietary information in Virginia Electric and Power Company's transmittal that SGH requests be withheld:
- Attachment 1, Supplemental Response, Alternative Request to Use Carbon Fiber Reinforced Polymer System for the Repair of Buried Circulating and Service Water Piping (3) In making this application for withholding of proprietary information of which it .is the owner, SGH believes that the information qualifies for withholding under the exemption from disclosure set forth in .the Freedom oflnforniation Act ("FOIA"), 5 U.S.C. Section 552(b)(4), the Trade Secrets Act, 18 U.S.C. Section 1905, and NRC regulations 10 CFR 9. 17(a)(4) and 2.390(a)(4) for trade secrets and commercial information be.cause: 1. This information is and has been held in confidence by SGH. ii. This information is of a type that is customarily held in confidence by SGH, and there is a rational basis for doing so because the information includes proprietary information that was developed and compiled by SGH at a significant cost to SGH. This information is classified as proprietary because it contains information relevant to analytical approaches and methodologies not available elsewhere. m. The. information is being transmitted to the NRC voluntarily and in confidence. iv. This information is not available in public sources and couid not be gathered readily from other publicly available information. v. A substantial effort has been expended by SGH to develop and evaluate this information. Public release ofthis information could lead to additional significant cost to SGH and is likely to cause substantial harm to SGH's competitive position and foreclose or redu.ce the ayailability of profit-making opportunities. The value of this information to SGH would be lost or devalued if the information wete disclosed to the public. Affidavit Page 1 \\\DC* OJS 120/000001
- 3152313 vi vi. Public disclosure of the information sought to be withheld would provide other parties, including competitors, with valuable information. SGH's competitive advantage would be lostif its competitors are able to use the results of SOI-I's activities to aid their own commercial activities. For example, SGH's competitive advantage would be lost if its competitors are able to use the results of SGH' s analyses to normalize or verify their own process or if they are able to claim an equivalent understanding by demonstrating that they can arrive at the same or similar conclusions. Making such information available to competitors without their having been required to undertake a similar expenditure of resources would unfairly provide competitors with a windfall, and deprive SGH of the opportunity to exercise its competitive advantage to seek an adequate return on its large investment. vii. The commercial value of the information extends beyond the original development cost, and includes development of the expertise to determine and apply the appropriate evaluation process to the information. The research, development, engineering, and analytical costs thatwent into generating this . information comprise a substantial investment of time and money by SGH. The precise value of this information is difficult to quantify, but clearly is substantial. I declare under penalty of perjury under the laws of the United States of America that the foregoing is true and correct. Executed on 17, 2017. Rasko P. Affidavit Page 2 \\\DC ,*0351201000001*3152313 vi