Email, Request for Additional Information, License Amendment Request to Add New Surveillance Requirement 3.3.8.6 to Technical Specification 3.3.8, Emergency Exhaust System (EES) Actuation Instrumentation
ML111390401
Person / Time
Site: Callaway Ameren icon.png
Issue date: 05/19/2011
From: Polickoski J
Plant Licensing Branch IV
To: Elwood T, Maglio S
Union Electric Co
Polickoski J, NRR/DORL/LPL4, 415-5430
Shared Package
ML111390388 List:
References
TAC ME5173
Download: ML111390401 (1)


Text

From: Polickoski, James Sent: Thursday, May 19, 2011 10:57 AM To: Maglio, Scott A; Elwood, Thomas B Cc: Thadani, Mohan; Markley, Michael; Lent, Susan; Burkhardt, Janet; Benton, Laray

Subject:

RAI re: LAR for new SR 3.3.8.6 to TS 3.3.8 dated December 10, 2010 Attachments: Callaway EES SR LAR.RAI 19 May 2011.docx Signed By: james.polickoski@nrc.gov Scott/Tom:

The NRC staff has reviewed your license amendment application dated December 10, 2010 for the Callaway Plant - Union Electric Companys request to add new Surveillance Requirement 3.3.8.6 to Technical Specification 3.3.8, Emergency Exhaust System Actuation Instrumentation. Based on that review and as mentioned in our phone discussion on May 19, 2011, the NRC staff has identified a need for additional information as outlined in the attached request for additional information (RAI).

The staff requests a response by June 17, 2011.

Thank you for your attention in this matter, Jim James T. Polickoski Project Manager - Callaway, Diablo Canyon US NRC/NRR/DORL/LPL4 james.polickoski@nrc.gov 301-415-5430