ML23114A230

From kanterella
Jump to navigation Jump to search

NRR E-mail Capture - Regulatory Audit Question - Callaway LAR and Exemption for Fuel Transition to Framatome Gaia Fuel - EPIDs - L-2022-LLA-0150 and L-2022-LLE-0030
ML23114A230
Person / Time
Site: Callaway 
(NPF-30)
Issue date: 04/24/2023
From: Mahesh Chawla
NRC/NRR/DORL/LPL4
To: Elwood T
Ameren Missouri
References
L-2022-LLE-0030, L-2022-LLA-0150
Download: ML23114A230 (3)


Text

From:

Mahesh Chawla Sent:

Monday, April 24, 2023 3:01 PM To:

Elwood, Thomas B Cc:

Jennifer Dixon-Herrity; Scott Krepel; Mathew Panicker; Ahsan Sallman; Diana Woodyatt; Santosh Bhatt; Jeremy Dean; Andrea Keim; Gerry Stirewalt; Donald Palmrose; Ravi Grover; Vic Cusumano

Subject:

Regulatory Audit Question - Callaway LAR and Exemption for Fuel Transition to Framatome GAIA Fuel - EPIDs - L-2022-LLA-0150 and L-2022-LLE-0030

Dear Mr. Elwood,

By application dated October 12, 2022 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML22285A115), as supplemented by letter dated December 1, 2022 (ML22335A497), Union Electric Company, doing business as Ameren Missouri (the licensee), submitted a license amendment request (LAR) and an exemption request for Callaway Plant, Unit No. 1. The proposed amendment would revise the technical specifications to allow use of Framatome GAIA fuel with M5 as a fuel cladding material. Since the Framatome GAIA fuel will use M5 fuel rod cladding, a Title 10 of the Code of Federal Regulations (10 CFR)

Section 50.46, Acceptance criteria for emergency core cooling systems for light-water nuclear power reactors, and 10 CFR Part 50 Appendix K exemption request is included as part of this LAR.

On March 20, 2023, the U.S. Nuclear Regulatory Commission (NRC) staff issued a letter indicating their plans for a regulatory audit and setup of online reference portal request to the licensee. The audit plant included the request for documents and the audit questions from the NRC staff. The regulatory audit was conducted from April 4 through 6, 2023, during which licensee provided the pertinent information for the subject application. The NRC staff has developed following audit question which they would like the licensee to provide additional information.

AUDIT QUESTION Table 28 of FS1-0042400, Mechanical compatibility of GAIA with co-resident fuel (VANTAGE) lists spacer and mixing grid centerline elevations for GAIA and resident fuel in the Callaway core. Discuss the impact on mechanical compatibility between the two fuel assemblies because of the non-alignment of spacer and mixing grids of two fuels as per Table 28.

Please include the response to this request in addition to the previously discussed audit questions. Thanks Sincerely, Mahesh Chawla, Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission ph: 301-415-8371 Docket No. 50-483

OFFICE DORL/LPL4/PM DORL/LPL4/BC NAME MChawla JDixon-Herrity DATE 4/24/23 4/24/23

Hearing Identifier:

NRR_DRMA Email Number:

2047 Mail Envelope Properties (SA1PR09MB841510C51D0CD244E24AB6C0F1679)

Subject:

Regulatory Audit Question - Callaway LAR and Exemption for Fuel Transition to Framatome GAIA Fuel - EPIDs - L-2022-LLA-0150 and L-2022-LLE-0030 Sent Date:

4/24/2023 3:00:39 PM Received Date:

4/24/2023 3:00:40 PM From:

Mahesh Chawla Created By:

Mahesh.Chawla@nrc.gov Recipients:

"Jennifer Dixon-Herrity" <Jennifer.Dixon-Herrity@nrc.gov>

Tracking Status: None "Scott Krepel" <Scott.Krepel@nrc.gov>

Tracking Status: None "Mathew Panicker" <Mathew.Panicker@nrc.gov>

Tracking Status: None "Ahsan Sallman" <Ahsan.Sallman@nrc.gov>

Tracking Status: None "Diana Woodyatt" <Diana.Woodyatt@nrc.gov>

Tracking Status: None "Santosh Bhatt" <Santosh.Bhatt@nrc.gov>

Tracking Status: None "Jeremy Dean" <Jeremy.Dean@nrc.gov>

Tracking Status: None "Andrea Keim" <Andrea.Keim@nrc.gov>

Tracking Status: None "Gerry Stirewalt" <Gerry.Stirewalt@nrc.gov>

Tracking Status: None "Donald Palmrose" <Donald.Palmrose@nrc.gov>

Tracking Status: None "Ravi Grover" <Ravinder.Grover@nrc.gov>

Tracking Status: None "Vic Cusumano" <Victor.Cusumano@nrc.gov>

Tracking Status: None "Elwood, Thomas B" <TElwood@ameren.com>

Tracking Status: None Post Office:

SA1PR09MB8415.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 2237 4/24/2023 3:00:40 PM Options Priority:

Normal Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date: