ML22151A051

From kanterella
Jump to navigation Jump to search

NRR E-mail Capture - Final - Request for Additional Information - Columbia Generating Station - LAR to Change TS 3.4.11 - Reactor Coolant System Pressure and Temperature Limits - EPID L-2021-LLA-0191
ML22151A051
Person / Time
Site: Callaway 
(NPF-30)
Issue date: 05/27/2022
From: Mahesh Chawla
Plant Licensing Branch IV
To: Ronnie Garcia
AmerenUE
References
L-2021-LLA-0191
Download: ML22151A051 (6)


Text

From:

Chawla, Mahesh Sent:

Friday, May 27, 2022 5:55 PM To:

'Garcia, Richard M.'

Cc:

Dixon-Herrity, Jennifer; Orders, William; Tsao, John; Hamm, Matthew; Scully, Derek; Smith, Ashley; Forsaty, Fred; Wagage, Hanry; Moyer, Carol

Subject:

Final - Request for Additional Information - Columbia Generating Station -

LAR to change TS 3.4.11 - Reactor Coolant System Pressure and Temperature Limits - EPID L-2021-LLA-0191 Attachments:

Columbia Final RAIs_L-2021-LLA-0191.docx

Dear Mr. Garcia,

By letter dated October 13, 2021 (Agencywide Documents and Access Management System (ADAMS) Accession No. ML21299A182), Energy Northwest (the licensee) requested to revise Technical Specification (TS) 3.4.11, Reactor Coolant System Pressure and Temperature (P/T)

Limits, at the Columbia Generating Station (CGS). The license amendment request will replace the P/T (P-T) limit curves for inservice leak and hydrostatic testing, non-nuclear heating and cooldown, and nuclear heating and cooldown in TS Figures 3.4.11-1, 3.4.11-2, and 3.4.11-3, respectively. In addition, the licensee provided the revised P/T curves to satisfy the license renewal commitment Number 54 in Appendix A, Table A-1 of NUREG-2123 "Safety Evaluation Report Related to the License Renewal of Columbia Generating Station," which the Nuclear Regulatory Commission (NRC) published in May 2012 (ML12139A300 and ML12139A302).

A teleconference was held between the representatives of Energy Northwest and the NRC staff on May 26th, 2022 to discuss the request for additional information. During the call there were minor changes agreed upon to be made to the draft RAIs transmitted on May 18, 2022 The final RAIs are attached to this email. In an email, you have agreed to provide the response to this request within 45 calendar days or no later than July 12th 2022. This takes into account the two public holidays in between this time period. In case of any further questions/concerns please contact me.

Thanks Sincerely, Mahesh Chawla, Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission ph: 301-415-8371 Docket No. 50-483 OFFICE DORL/LPL4/PM DORL/LPL4/BC

NAME MChawla JDixon-Herrity DATE 5/18/22 5/18/22

Hearing Identifier:

NRR_DRMA Email Number:

1655 Mail Envelope Properties (PH0PR09MB841129C83164AE1DFE5F5078F1D89)

Subject:

Final - Request for Additional Information - Columbia Generating Station - LAR to change TS 3.4.11 - Reactor Coolant System Pressure and Temperature Limits - EPID L-2021-LLA-0191 Sent Date:

5/27/2022 5:54:39 PM Received Date:

5/27/2022 5:54:40 PM From:

Chawla, Mahesh Created By:

Mahesh.Chawla@nrc.gov Recipients:

"Dixon-Herrity, Jennifer" <Jennifer.Dixon-Herrity@nrc.gov>

Tracking Status: None "Orders, William" <William.Orders@nrc.gov>

Tracking Status: None "Tsao, John" <John.Tsao@nrc.gov>

Tracking Status: None "Hamm, Matthew" <Matthew.Hamm@nrc.gov>

Tracking Status: None "Scully, Derek" <Derek.Scully@nrc.gov>

Tracking Status: None "Smith, Ashley" <Ashley.Smith@nrc.gov>

Tracking Status: None "Forsaty, Fred" <Fred.Forsaty@nrc.gov>

Tracking Status: None "Wagage, Hanry" <Hanry.Wagage@nrc.gov>

Tracking Status: None "Moyer, Carol" <Carol.Moyer@nrc.gov>

Tracking Status: None

"'Garcia, Richard M.'" <rmgarcia@energy-northwest.com>

Tracking Status: None Post Office:

PH0PR09MB8411.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 1817 5/27/2022 5:54:40 PM Columbia Final RAIs_L-2021-LLA-0191.docx 39798 Options Priority:

Normal Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

REQUEST FOR ADDITIONAL INFORMATION LICENSE AMENDMENT REQUEST REVISED PRESSURE TEMPERATURE LIMIT CURVES IN TECHNICAL SPECIFICATIONS COLUMBIA GENERATING STATION ENERGY NORTHWEST DOCKET NO. 50-397 EPID L-2021-LLA-0191 By letter dated October 13, 2021 (Agencywide Documents and Access Management System (ADAMS) Accession No. ML21299A182), Energy Northwest (the licensee) requested to revise Technical Specification (TS) 3.4.11, Reactor Coolant System Pressure and Temperature (P/T)

Limits, at the Columbia Generating Station (CGS). The license amendment request will replace the P/T limit curves for inservice leak and hydrostatic testing, non-nuclear heating and cooldown, and nuclear heating and cooldown in TS figures 3.4.11-1, 3.4.11-2, and 3.4.11-3, respectively. In addition, the licensee provided the revised P/T curves to satisfy the license renewal commitment No. 54 in appendix A, table A-1 of NUREG-2123 "Safety Evaluation Report Related to the License Renewal of Columbia Generating Station," which the Nuclear Regulatory Commission (NRC) dated May 2012 (ML12139A300 and ML12139A302).

To complete its review, the NRC staff requests additional information:

Regulatory Basis The regulations in Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Appendix G, require: (1) sufficient fracture toughness for reactor pressure vessel (RPV) ferritic materials to provide adequate safety margins during any condition of normal operation, including anticipated operational occurrences and system hydrostatic tests; (2) P/T limits that satisfy the American Society of Mechanical Engineers (ASME) Code, section XI, appendix G, and the minimum temperature requirements during normal heat-up, cool-down, and pressure test operations; and (3) applicable surveillance data from RPV material surveillance programs developed in accordance with 10 CFR Part 50, appendix H, Reactor Vessel Material Surveillance Program Requirements, be incorporated into the calculations of P/T limits.

Regulatory Guide (RG) 1.99, Revision 2, Radiation Embrittlement of Reactor Vessel Materials, dated May 1988 (ML003740284), describes procedures for calculating the adjusted nil-ductility transition reference temperature RTNDT (ART) due to neutron irradiation on RPVs.

Requests for Additional Information (RAIs)

RAI-1

Issue (1) Section 3.3 of NEDO-33929, Energy Northwest/Columbia Generating Station Pressure and Temperature Limits Report (PTLR) up to 54 effective full-power years, in the license amendment request discusses initial reference nil ductility transition temperature (RTNDT).

Appendix B of NEDO-33929 presents the initial RTNDT of various RPV materials. TS figures 3.4.11-1 and 3.4.11-3 show the initial RTNDT for the upper vessel and bottom head. The NRC staff is not clear how the initial RTNDT was derived because section 3.3 and appendix B (Tables B-1 to B-4) of NEDO-33929 do not show the initial RTNDT of the upper vessel and bottom head.

(2) The initial RTNDT for the bottom head in TS figures 3.4.11-1 and 3.4.11-3 is different from that of TS figure 3.4.11-2. The NRC staff is not clear why the initial RTNDT for the same bottom head is different in these figures.

(3) Section 3.3 of NEDO-33929 indicates that the initial RTNDT values for various RPV materials, such as the bottom head, used in the P/T curves are proprietary information. However, TS figures 3.4.11-1, 3.4.11-2, and 3.4.11-3 present the initial RTNDT values for the same RPV materials as non-proprietary. The NRC staff is not clear why two different proprietary information classifications exist for the same RTNDT values of the same RPV materials.

Request (1) Discuss how the initial RTNDT of the upper vessel and bottom head is derived.

(2) Clarify the discrepancy in the initial RTNDT value for the bottom head between figures 3.4.11-1/3.4.11-3 and figure 3.4.11-2.

(3) Clarify the discrepancy in the proprietary information classifications.

RAI-2

Issue (1) Note 2 to 10 CFR Part 50, appendix G, table 1 specifies that the RPV minimum temperature requirement under several operating conditions is The highest reference temperature of the material in the closure flange region that is highly stressed by the bolt preload. Table B-1 of NEDO-33929 shows a RTNDT for the RPV head flange, and TS figures 3.4.11-1, 3.4.11-2, and 3.4.11-3 show a different initial RTNDT for the upper vessel. The NRC staff is not clear on what is the highest reference temperature in the closure flange region that is used in TS figures 3.4.11-1, 3.4.11-2, and 3.4.11-3. In addition, the NRC staff is not clear whether the initial RTNDT for the upper vessel in the three TS figures is applicable to the RPV head flange (i.e., is the initial RTNDT for the upper vessel to be used for the RPV head flange?)

(2) The nuclear heating and cooldown curve in proposed TS figure 3.4.11-3 shows the minimum vessel temperature as 80 oF at 60 pounds per square inch gauge (psig). The NRC staff is not clear whether the 80 degrees Fahrenheit (oF) temperature satisfies the minimum temperature requirements of 10 CFR Part 50, appendix G.

(3) Appendix G to 10 CFR Part 50, table 1, item 2.d requires that when the reactor internal pressure is > 20 percent of the preservice system hydrostatic test pressure, the minimum temperature must be larger than the minimum permissible temperature for the inservice system hydrostatic pressure test or closure flange RTNDT plus 160 °F. The NRC staff is not clear the proposed TS figure 3.4.11-3 satisfies this requirement.

(4) The NRC staff is not clear whether TS figures 3.4.11-1, 3.4.11-2, and 3.4.11-3 satisfy the minimum temperature requirements of 10 CFR Part 50, appendix G, table 1.

Request (1) Discuss the highest reference temperature of the material in the closure flange region that is highly stressed by the bolt preload used in the proposed P/T curves. Clarify whether the initial RTNDT for the upper vessel in the three TS figures is applicable to the RTNDT of the RPV closure flange as specified in table 1 of 10 CFR Part 50, appendix G.

(2) Discuss the minimum permissible temperature for the inservice system hydrostatic pressure test.

(3) Discuss how TS figures 3.4.11-1, 3.4.11-2, and 3.4.11-3 satisfy the minimum temperature requirements in item numbers 1a, 1b, 2a, 2b, 2c, 2d, and 2e of 10 CFR Part 50, appendix G, table 1.

RAI-3

Issue TS figures 3.4.11-1 and 3.4.11-2 contain a P/T curve for the bottom head and a minimum temperature for the bottom head. The NRC staff is not clear how the bottom head P/T curve is monitored and whether the minimum temperature value shown in TS figures 3.4.11-1 and 3.4.11-2 satisfies the minimum temperature requirements of 10 CFR Part 50, appendix G.

Request (1) Discuss whether the pressure and temperature at the bottom head region are not exceeded during the inservice leak and hydrostatic testing and non-nuclear heat-up and cool-down operation.

(2) Discuss how the minimum temperature for the bottom head curves in TS figures 3.4.11-1 and 3.4.11-2 satisfies requirements in item numbers 1a, 1b, 2a, and 2b of 10 CFR Part 50, appendix G, table 1.

RAI-4

Issue Section 3.6 of the licensees report NEDC-33929P in the license amendment request states that CGS has two indications in a reactor vessel beltline weld and that these indications were not reviewed in the NEDO-33929P report. The NRC staff notes that the purpose of the P/T limit curve is to protect the structural integrity of the reactor vessel. Therefore, the existence of these two indications cannot be ignored when generating new P/T limit curves. The NRC staff is not clear whether the two indications affect the P/T limit curves and reactor vessel structural integrity.

Request Discuss why the two indications do not affect the construction of the P/T limit curves. In the discussion, include the following information: (a) the length, depth, and orientation of the two indications, (b) discuss whether the indications are located in a longitudinal or circumferential weld, (c) discuss the location of the indications with respect to the wall thickness of the beltline weld, and (d) discuss whether the two indications are embedded in the weld or are connected to the inside diameter surface of the RPV.