ML16292A718

From kanterella
Revision as of 14:06, 30 October 2019 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search

Response to NRC Question Regarding Dbnps FIP Associated with Fuel Oil Quality
ML16292A718
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 10/18/2016
From: John Hughey
Japan Lessons-Learned Division
To: Jeremy Bowen
Office of Nuclear Reactor Regulation, Japan Lessons-Learned Division
References
Download: ML16292A718 (3)


Text

NRR-PMDAPEm Resource From: Hughey, John Sent: Tuesday, October 18, 2016 11:04 AM To: Bowen, John; Armstrong, Garry

Subject:

FW: Response to NRC Question Regarding DBNPS FIP John and Gary, Please note that the e-mail below is being added to ADAMS.

Thanks, John John Hughey Mitigation Strategies & SFP Instrumentation Project Manager, NRR/JLD/JOMB US Nuclear Regulatory Commission Phone: (301) 415-3204 Office: O13-H08 e-mail: john.hughey@nrc.gov From: Nevins, Kathleen J. [1]

Sent: Tuesday, October 11, 2016 11:36 AM To: Hughey, John Cc: Lentz, Thomas A. (Licensing)

Subject:

[External_Sender] Response to NRC Question Regarding DBNPS FIP During the October 6, 2016 acceptance review call for the Davis-Besse Nuclear Power Station (DBNPS) Final Integrated Plan (FIP), the NRC staff had follow-up questions. The NRC question is identified in bold below, followed by the DBNPS response.

From Section 2.9.5 of the DBNPS FIP:

1) How is fuel oil quality determined for the 6,000 gal tank that is located in the EFWF?

Prior to the Station accepting fuel oil from our approved vendors, for use on site, the fuel oil must be sampled by the Chemistry Department and accepted per DB-CH-06900, Operational Chemical Control Limits, DB-CH-03044, New EDG Diesel Fuel Oil Analysis and/or DB-CH-04056, New Diesel Fuel Oil Analysis. The 6,000 gallon EFWF Fuel Oil Storage Tank has been added to the chemistry monitoring program and is periodically sampled following the requirements of DB-CH-06900, Operational Chemical Control Limits, Section 10.

2) How is fuel oil quality determined for all of the other EDMG equipment (for example: EFW Pump Diesel and the 850 kW Flex generator)?

The initial fuel quality is verified as discussed in Question 1. Ongoing monitoring of the Week tanks, EDG Day Tanks and EFWF Fuel Oil Storage Tank are periodically sampled following the requirements of DB-CH-06900, Operational Chemical Control Limits, Section 10. The portable 850 kW generators do not have fuel oil storage tanks, but rather receive their fuel oil directly through an attachment hose from the EFW Fuel Oil Storage Tank or a K-1 1,200 gallon Fuel Storage Trailer. The N 850 kW turbine generator is connected to the 6,000 gallon EFWF Fuel Oil Storage Tank prior to operation via flexible fuel hose. The N+1 850 kW turbine generator is connected to a 1,200 gallon Fuel Oil Storage Trailer prior to operation via flexible fuel hose.

1

The 1,200 gallon Fuel Oil Storage Trailer, portable FLEX pumps and small portable 6 kW Diesel Generators, which are stored in indoor temperature controlled facilities, are initially filled with fuel oil that was sampled before acceptance as discussed in Question 1. These portable units are then drained and refilled annually to assure fuel oil quality, controlled by Preventive Maintenance Tasks.

Thank you.

Kathleen J. Nevins Fleet Licensing A-WAC-B1 2

Hearing Identifier: NRR_PMDA Email Number: 3108 Mail Envelope Properties (John.Hughey@nrc.gov20161018110400)

Subject:

FW: Response to NRC Question Regarding DBNPS FIP Sent Date: 10/18/2016 11:04:06 AM Received Date: 10/18/2016 11:04:00 AM From: Hughey, John Created By: John.Hughey@nrc.gov Recipients:

"Bowen, John" <John.Bowen@nrc.gov>

Tracking Status: None "Armstrong, Garry" <Garry.Armstrong@nrc.gov>

Tracking Status: None Post Office:

Files Size Date & Time MESSAGE 2831 10/18/2016 11:04:00 AM Options Priority: Standard Return Notification: No Reply Requested: No Sensitivity: Normal Expiration Date:

Recipients Received: