ML22040A183
| ML22040A183 | |
| Person / Time | |
|---|---|
| Site: | Davis Besse |
| Issue date: | 02/07/2022 |
| From: | Tom Gurdziel Public Commenter |
| To: | Viktoria Mitlyng NRC/RGN-III |
| Shared Package | |
| ML22040A184 | List: |
| References | |
| LTR-22-0033 | |
| Download: ML22040A183 (1) | |
Text
1 Chairman Resource From:
tgurdziel@twcny.rr.com Sent:
Monday, February 7, 2022 9:05 PM To:
Mitlyng, Viktoria Cc:
Chairman Resource; Screnci, Diane; Fellows, David E:(Exelon Nuclear); Esberg, John R:(GenCo-Nuc)
Subject:
[External_Sender] Event Number 55734 at Davis Besse, A Matter of Interpretation HiVictoria,
IhavereadthisEventReportandhaveoneortwoobservations/questions.
AsIseeit,thisOperatingcrewisolatedasystemthatshouldnothavebeenisolatedatabout 1402hr.andthenenteredanLCOfor1hourat1414hr.At1514hr.(onehourlater),they apparentlydidnotsatisfyConditionAofthatLCOandthenweredirectedbyConditionBto
placetheUnitinMODE3in6hoursandinMODE4in12hours.
Whywasntthisadditional,cleardirectionfollowed?Iwouldlikeanexplanationonhowthis Operatingshift,includinganyonshiftsupervisionsuchasalicensedShiftManager, interpretedthisdirectionotherthantoshutdowntheplant.
Additionally,IwouldliketoknowifitwasaLICENSEDoperatorthatisolatedthesystemorifit wasanUNLICENSEDworkernotproperlysupervisedwhodidthesystemisolation.And,was theworkdoneasaskillofthetradeorbyfollowinganadequate,uptodateprocedure?
- Thankyou,
Tom
Ofcourse,mybasicquestionisreallythis:dothepresentpeopleatDavisBesseknowwhich waytoturnthevalvehandletocloseavalveanddotheyknowwhichwaytoturnthehandle toopenavalve?