Davis-Besse Nuclear Power Station, Unit No. 1 - Acceptance of Proposed Alternative RR-A2 for Certain Steam Generator Weld Inspections Mr. Lashley:

By application dated September 13, 2021 (ADAMS Accession No. ML21256A119), Energy Harbor Nuclear Corp. (the licensee) submitted a request in accordance with paragraph 50.55a(z)(1) of Title 10 of the Code of Federal Regulations (10 CFR) for a proposed alternative to certain requirements of 10 CFR 50.55a, Codes and standards, at Davis-Besse Nuclear Power Station, Unit No. 1. Specifically, the application requests U.S. Nuclear Regulatory Commission (NRC) approval to increase the inspection interval for certain steam generator welds.

The purpose of this email is to provide the results of the NRC staffs acceptance review of this proposed alternative. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.

The NRC staff has reviewed your application and concluded that it provides technical information in sufficient detail to enable the staff to complete its detailed technical review and make an independent assessment regarding the acceptability of the proposed alternative in terms of regulatory requirements and the protection of public health and safety and the environment. Given the lesser scope and depth of the acceptance review, as compared to the detailed technical review, there may be instances in which issues that impact the staffs ability to complete the detailed technical review are identified despite completion of an adequate acceptance review. You will be advised of any further information needed to support the staffs detailed technical review by separate correspondence.

Based on the information provided in your submittal, the NRC staff estimates that review of this request will take approximately 200 hours0.00231 days <br />0.0556 hours <br />3.306878e-4 weeks <br />7.61e-5 months <br /> to complete. The staff expects to complete its review by March 15, 2022. These estimates are based on the staffs initial review of the application and they could change due to several factors, including requests for additional information. If there are emergent complexities or challenges in our review that would cause changes to the initial forecasted completion date or significant changes to the forecasted hours, I will inform you of the reason for the change and provide the new estimates.

Sincerely, Blake Purnell, Project Manager Plant Licensing Branch III Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission ph: 301-415-1380

Docket No. 50-346 EPID L-2021-LLR-0067

Hearing Identifier:

NRR_DRMA Email Number:

1361 Mail Envelope Properties (BLAPR09MB6497B4258C4B849E6307DEB2E6A89)

Subject:

Davis-Besse Nuclear Power Station, Unit No. 1 - Acceptance of Proposed Alternative RR-A2 for Certain Steam Generator Weld Inspections Sent Date:

9/28/2021 10:24:53 AM Received Date:

9/28/2021 10:24:00 AM From:

Purnell, Blake Created By:

Blake.Purnell@nrc.gov Recipients:

"Nesser, Kathryn M" <kmnesser@energyharbor.com>

Tracking Status: None "Nevins, Kathleen J" <kjnevins@energyharbor.com>

Tracking Status: None "Salgado, Nancy" <Nancy.Salgado@nrc.gov>

Tracking Status: None "Lashley, Phil H (EH)" <phlashley@energyharbor.com>

Tracking Status: None Post Office:

BLAPR09MB6497.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 2775 9/28/2021 10:24:00 AM Options Priority:

Normal Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date: