Forwards LER 98-029-01, Fuel Handling Area Ventilation Sys Inoperable Due to Original Design Deficiency. Supplemental Rept Represents Extensive Rev to Original LER & Replaces Rept in Entirely.Commitment Listed
ML17326A075
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 08/04/1999
From: Bakken A
INDIANA MICHIGAN POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML17326A076 List:
References
NUDOCS 9908100138
Download: ML17326A075 (2)


Text

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESS1ON NBR:9908100138 DOC.DATE: 99/08/04 NOTARIZED- NO FACIL:50-315,Donald C. Cook Nuclear Power Plant, Unit 1, Indiana DOCKET ¹ M 05000315 AUTH. NAME AUTHOR AFFILIATION BAKKEN,A.C. ~

Indiana Michigan Power Co. ~

RECIP . NAME RECIPIENT AFFILIATION Records Management Branch (Document Control Desk)

SUBJECT:

Forwards LER 98-029-01, "Fuel Handling Ventilation Sys Inoperable Due to Original Design Deficiency." Supplemental rept represents extensive rev to original LER Ec replaces rept entirely. Commitment made by licensee, listed.

DISTRIBUTION CODE: IE22T COPIES RECEIVED:LTR i ENCL SIZE:

TITLE: 50.73/50.9 Licensee Event Report (LER), Incident pt, etc.

NOTES:

RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ZD CODE/NAME LTTR ENCL LPD 1 1 STANG, J 1 1 INTERN 1 1 NRR/DIPM/ZOLB 1 '

NRR/DRIP/REXB 1 1 NRR/DSSA/SPLB 1 1 RES/DET/ERAB 1 1 RES/DRAA/OERAB 1 1 RGN3 FILE 01 1 1 EXTERNAL: L ST LOBBY WARD 1 1 LMZTCO MARSHALL 1 ~ 1 NOAC POORE,W. 1 1 NOAC QUEENER,DS 1 1 NRC PDR 1 1 NUDOCS FULL TXT 1 1 WASTETH NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LIS'.

OR REDUCE THE NUMBER OF COPIES RECEIVED BY'YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTR(

DESK (DCD) ON EXTENSION 415-2083 FULL TEXT CONVERSION REQUIRED TOTAL NUMBER OF COPIES REQUIR"D: LTTR 15 ENCL 15

Indiana Michiga~

Power Company Cook Nudear Rant

~

One Cook Rant etkkrnantAI49106 61 6 465 690i fNOltLMA NlCHIGAM PQMI/nR August 4, 1999 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Operating License DPR-58 Docket No. 50-315 Document Control Manager:

In accordance with the criteria established by 10 CFR 50.73 entitled Licensee Event Re ort S stem the following supplemental report is being submitted:

LER 315/98-029-01, "Fuel Handling Area Ventilation System Inopeiable Due to Original Design Deficiency". This supplemental report represents an extensive revision to the original LER and replaces that report in its entirety.

The following commitment was identified in this LER.

~ The radiological analysis for the Spent Fuel Handling Accidents in the Auxiliary Building is being redone and is scheduled to be completed by August 30, 1999.

Sincerely, A. Christopher Bakken III Site Vice President

/Irb Attachment c: J. E. Dyer, Region III R. P. Powers P. A. Barrett G. P. Arent R. Whale D. Hahn Records Center, INPO NRC Resident Inspector 9908fOOi38 990804 PDR S