Text

NRC FORM Sdd 77.77)LICENSEE EVENT REPORT U.S NUCLEAR RKQULATORY COMMISSION CONTROI.SLOCIEI I I I I>OI (PLEASE PRINT OR TYPE ALL REOUIREO INFORMATIONI 9 LIcaNsaa cooa 14',5 O.LICiNSE rYUMSKR 25 LrCKNSK TYP4 40$7<<A~5 CON'T~o 7 3 AEPQAT LL+Id I I E I I Q9 SO$1 OOCIIET NUMSKR$539 EVENT OAT'E 74 7$REPORT OA a 30 EVENT OESCRIPTION ANO PROBASLE CONSEQUENCES

+Io While o eratin at 100%ower the level transmitter on the 1Bl SIT drifted~or Fl LIS L Sll r 0 0-0 0101010-00 Qr4 11 I IQ~Qr~os out of calibration and the tank level dro ed below the limit specified by TS 3.5.1.A low-low level alarm was received from the fixed ca acitance~0$robe.The tank level was restored in accordance with TS 3.5.1.No n e ence e 1 ed from hi occurrence.

This was the first~o 7 occurrence of this t e.~oa 7 3 9~OS action consisted of adjustin the level indicator in the control room based SYSTE'4 CAU5$CAUSE COMP.VALVE COOK COOS 5VSCOOE CCMPQNENT COOK suacooa suecooa~S err LJrr I LJ.J J J JG mrrr LIJrr 7 5 9 lo 11 12 IS 1$19 20 SEOVENTIAI.

OCCUAAENC4 AKPOAT REVISION EVENT YEAR A EIrO AT NO COOK TYPE~NQ.QrL rrrrrrr~79~~02 9~w~03~L~~0 21 22 22 2$'27 25 29 20 2I 22 ACTION PUTUAE EPPEC SI4VTOQWN ATTACI4MENT NPAOM PAIMKCOMD.

COMPONENT TAXKN ACTION CN PLANT MKTIIQD AQUAS Q22 5VSMITTKO POAM SUS.SUPPLIER MANUFACTURER rrrrLJS L~lrr Llrr'r'ES BJO US~rr 4 24 2$2$~40 41 42 44 41 CAUSE OESCRIPTION ANO CORRECTIVE ACTIONS 027 o No s ecific cause Immediat on level determined from the fixed ca acitance robe.The transmitter located inside the containment was recalibrated the following week during a scheduled outa e.No further action was.re uired.7$9 sTATUs NPOYIER QTIIER STATUS Oao PACII I Yr~IE~O2E~0~@NA 7$9 10 12 12 44 ACTIVITY CONTENT AELEASEO OP AELiASE'MQUNToP ACTIVITY QSS CZi~O LaO24 A 7 3 9 10 I~44 PKASONNEL KXPQSUAES~00 0 Qrr Z Qrrr NA 7 5 11 I'2 15 PERSONNEL INJURIES AIKTIIOO QP OI SCOV EAY~AOSI 4$4$45 OISCOVERY OESCAIPTION QS2 0 erator Observation LoCATIoN OP RELEASE QSE NA 7 3 9 11 12 LC55 QP QR QAMAQK To FACILITY Q42 TYPE OESCAIPTION CZ LZJO42 5 2'0 PU5LI CITY ISSUKQ OKSCAIPT:ON

~KH mO44 3 9:0 NAME OF PREPARER NA NA A.Scho man 30 NRC USE ONLY$$$9 30 PNoNE 305 552-3802 T922 OTO<PP