License Amendment Request (LAR) to Amend the Hope Creek Technical Specifications (TS) to Revise Action for Inoperable Emergency Diesel Generator (EDG) a or B
ML18087A095
Person / Time
Site: Hope Creek PSEG icon.png
Issue date: 03/28/2018
From: Carr E S
Public Service Enterprise Group
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
LAR H18-01, LR-N18-0013
Download: ML18087A095 (26)


Text

3/4 8-2

Items#Task Time(mins)Resources 0151525253030404045455555606065657070808085859090100100105105115115125125130130140140155155165165170170175175 180 1 StartofLOOP15 Ops X SeeNote1 2 DISPATCHoperator(s)andMaintenancetoDieselBuildingtoevaluateEDG 30 2I&C/Elec&Ops SeeNote1 3 DISPATCHpersonneltoOutdoorFlexStorageArea2(OFSA2)toMoveCableTrailer 10 2StockHandlers X SeeNote2 4 Openbreakerfor480Vpowersourcetoportabledieselgenerators.

5 2StockHandlers X SeeNote3 5 Disconnect480VCablesfromPortableDieselGenerators(DG)10 2StockHandlers X SeeNote3 6 HooktowvehicletodieselatDG#1 15 2StockHandlers SeeNote2 7 DriveDG#1toDeploymentLocatio n 10 2StockHandlers SeeNote2 8 DisconnectfromDG#1 15 2StockHandlers SeeNote2 9 DriveBacktoOFSA2 10 2StockHandlers SeeNote2 10 HooktowvehicletodieselatDG#2 15 2StockHandlers SeeNote2 11 DriveDG#2toDeploymentLocatio n 10 2StockHandlers X SeeNote2 12 DisconnectfromDG#2 15 2StockHandlers SeeNote2 13 DriveBacktoOFSA2 10 2StockHandlers X SeeNote2 14 HooktowvehicletodieselatDG#3 15 2StockHandlers X SeeNote2 15 DriveDG#3toDeploymentLocation.(Note:Donotneedtodisconnecttohookupcables)10 2StockHandlers X SeeNote2 16 DISPATCHpersonneltoOFSA2toMoveCableTrailer 10 2I&C/ElecX SeeNote2 17 Hooktrucktocabletraile r 5 2I&C/ElecX SeeNote3 18 DrivecabletrailertoDeploymentLocatio n 5 2I&C/ElecX SeeNote3 19 Opentheturbinebuildingroll updoor.5 2I&C/ElecX SeeNote3 20 OpensecuritygratingtotheReceptaclepanel.5 OPs X SeeNote3 21 Connectfour4/0cablesfromReceptaclePaneltojustoutsideRadiologicalControlledArea(RCA)forDG#1.15 2I&C/ElecSeeNote2 22 Connectfour4/0cablesfromReceptaclePaneltojustoutsideRCAforDG#2.15 2I&C/ElecSeeNote2 23 Connectfour4/0cablesfromTPCReceptaclePaneltojustoutsideRCAforDG#3.15 2I&C/ElecSeeNote2 24 Connectfour4/0cablesfromDG#1tocablesjustoutsideRCA.10 2I&C/ElecX SeeNote2 25 Connectfour4/0cablesfromDG#2tocablesjustoutsideRCA.10 2I&C/ElecX SeeNote2 26 justoutsideRCA.(Note:ThisoverlapswithItem15,butexpectationisthatcablesarepulledandwillbeconnectedimmediatelyonceDGinplace)10 2I&C/ElecX SeeNote2 27 Connectsynchcablesbetweeneachofthedieseltrailers.5 2I&C/ElecX SeeNote3 28 OpenBreakerBS6 7in13.8kVRingBu s 29 VerifySwitchgear10A403SR4.16kVBKR10A40308isOpen 30 VerifySwitchgear10A401SR4.16kVBKR10A40101isOpen 31 VerifySwitchgear10A401SR4.16kVBKR10A40108isClosed 32 VerifySwitchgear10A101SR4.16kVBKR10A10110isOpen 33 VerifySwitchgear10A101SR4.16kVBKR10A10101isClosed 34 Openlocktobreaker10A10104inSwitchgear10A101 35 StartDG's 10 2I&C/ElecSeeNote3 36 CloseBreaker10A10104inSwitchgear10A1015OpsXSeeNote3 Note1 Note2 Note3 Actions X X X X Thenextsteps28thru34&36arefortheAEDGoutofservice.X Notes SeeNote3 X X Minutes PerformanceTime X X Notes: TimefromProcedureHC.OP AB.ZZ 0135,StationBlackout/LossOffsitePower/DieselGeneratorMalfunction EstimatedTimefromValidationPlanNo.HCFLEX2015 12 17 C,TransportALTFLEXDieselGenerator EstimatedTimefromInterviewingOperators X X X25Ops Items#Task Time(mins)Resources 0151525253030404045455555606075759090105105115115125125135135140140150150 155 1 StartofLOOP15 Ops X SeeNote1 2 DieselBuildingtoevaluateEmergencyDieselGenerator 30 2I&C/Elec&Ops SeeNote1 3 DISPATCHpersonneltoOutdoorFlexStorageArea2toMoveCableTrailer 10 2I&C/ElecX SeeNote2 4 Opentheturbinebuildingroll updoor.5 2I&C/ElecX SeeNote3 5 OpensecuritygratingtotheReceptaclepanel.5 OPs X SeeNote3 6 Connectfour4/0cablesfromReceptaclePaneltojustoutsideRadiologicalControlledArea(RCA)forPortableDieselGenerator(DG)#1.15 2I&C/ElecX SeeNote2 7 Connectfour4/0cablesfromReceptaclePaneltojustoutsideRCAforDG#2.15 2I&C/ElecX SeeNote2 8 Connectfour4/0cablesfromReceptaclePaneltojustoutsideRCAforDG#3.15 2I&C/ElecX SeeNote2 9 Connectfour4/0cablesfromDG#1tocablesjustoutsideRCA.10 2I&C/ElecX SeeNote2 10 Connectfour4/0cablesfromDG#2tocablesjustoutsideRCA.10 2I&C/ElecX SeeNote2 11 Connectfour4/0cablesfromDG#3tocablesjustoutsideRCA.10 2I&C/ElecX SeeNote2 12 Connectsynchcablesbetweeneachofthedieseltrailers.5 2I&C/ElecX SeeNote3 13 OpenBreakerBS6 7in13.8kVRingBus 14 VerifySwitchgear10A403SR4.16kVBKR10A40308isOpen 15 VerifySwitchgear10A401SR4.16kVBKR10A40101isOpen 16 VerifySwitchgear10A401SR4.16kVBKR10A40108isClosed 17 VerifySwitchgear10A101SR4.16kVBKR10A10110isOpen 18 VerifySwitchgear10A101SR4.16kVBKR10A10101isClosed 19 Openlocktobreaker10A10104inSwitchgear10A101 20 StartDG's 10 2I&C/ElecX SeeNote3 21 CloseBreaker10A10104inSwitchgear10A1015Ops X SeeNote3 Note1 Note2 Note325Ops SeeNote3 X TimefromProcedureHC.OP AB.ZZ 0135,StationBlackout/LossOffsitePower/DieselGeneratorMalfunction Notes: EstimatedTimefromValidationPlanNo.HCFLEX2015 12 17 C,TransportALTFLEXDieselGenerator EstimatedTimefromInterviewingOperators Notes Actions PerformanceTime Minutes X Thenextsteps13thru19&21arefortheAEDGoutofservice.