ML20142A541
ML20142A541 | |
Person / Time | |
---|---|
Site: | Hope Creek ![]() |
Issue date: | 05/21/2020 |
From: | Public Service Enterprise Group |
To: | Office of Nuclear Reactor Regulation |
Shared Package | |
ML20142A521 | List:
|
References | |
LR-N20-0036 | |
Download: ML20142A541 (3) | |
Similar Documents at Hope Creek | |
---|---|
Category:Technical Specification
MONTHYEARLR-N24-0062, Proposed Changes to Enclosure 2 Volume 13, ITS Section 3.8 Electrical Power Systems, of the Improved Technical Specification Conversion License Amendment Request2024-10-17017 October 2024
[Table view]Proposed Changes to Enclosure 2 Volume 13, ITS Section 3.8 Electrical Power Systems, of the Improved Technical Specification Conversion License Amendment Request LR-N23-0024, Submittal of Hope Creek Generating Station Technical Specification Bases Changes2023-03-29029 March 2023 Submittal of Hope Creek Generating Station Technical Specification Bases Changes LR-N21-0078, Hope and Creek Generating Station, Supplement to License Amendment Request to Revise Technical Specifications (TS) to Delete Definitions Found in 10 CFR Part 20 and Delete Figures of the Site and Surrounding Areas from TS2021-11-18018 November 2021 Hope and Creek Generating Station, Supplement to License Amendment Request to Revise Technical Specifications (TS) to Delete Definitions Found in 10 CFR Part 20 and Delete Figures of the Site and Surrounding Areas from TS LR-N21-0079, Submittal of Hope Creek Generating Station Technical Specification Bases Changes2021-11-0303 November 2021 Submittal of Hope Creek Generating Station Technical Specification Bases Changes LR-N21-0025, License Amendment Request to Revise Technical Specification Limits for Ultimate Heat Sink2021-05-0707 May 2021 License Amendment Request to Revise Technical Specification Limits for Ultimate Heat Sink LR-N20-0060, Application to Revise Technical Specifications to Adopt TSTF-582, Reactor Pressure Vessel Water Inventory Control (RPV WIC) Enhancements2020-09-29029 September 2020 Application to Revise Technical Specifications to Adopt TSTF-582, Reactor Pressure Vessel Water Inventory Control (RPV WIC) Enhancements ML20142A5412020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Section 16, Technical Specifications LR-N20-0033, Submittal of Hope Creek Generating Station Technical Specification Bases Changes2020-05-15015 May 2020 Submittal of Hope Creek Generating Station Technical Specification Bases Changes LR-N20-0015, License Amendment Request to Revise Technical Specification Actions for Suppression Pool Cooling2020-05-0707 May 2020 License Amendment Request to Revise Technical Specification Actions for Suppression Pool Cooling LR-N18-0127, Application to Revise Technical Specifications to Adopt TSTF-546, Revise APRM Channel Adjustment Surveillance Requirement2019-02-27027 February 2019 Application to Revise Technical Specifications to Adopt TSTF-546, Revise APRM Channel Adjustment Surveillance Requirement ML19058A2212019-02-27027 February 2019 Application to Revise Technical Specifications to Adopt TSTF-546, Revise APRM Channel Adjustment Surveillance Requirement LR-N18-0013, License Amendment Request (LAR) to Amend the Hope Creek Technical Specifications (TS) to Revise Action for Inoperable Emergency Diesel Generator (EDG) a or B2018-03-28028 March 2018 License Amendment Request (LAR) to Amend the Hope Creek Technical Specifications (TS) to Revise Action for Inoperable Emergency Diesel Generator (EDG) a or B LR-N18-0011, Supplement to License Amendment Request- Safety Limit Minimum Critical Power Ratio Change. Includes GNF-004N5379-R1-NP, GNF Additional Information Regarding the Requested Changes to the Technical Specification SLMCPR2018-01-22022 January 2018 Supplement to License Amendment Request- Safety Limit Minimum Critical Power Ratio Change. Includes GNF-004N5379-R1-NP, GNF Additional Information Regarding the Requested Changes to the Technical Specification SLMCPR LR-N17-0163, License Amendment Request - Safety Limit Minimum Critical Power Ratio Change, Non-Proprietary2017-11-0909 November 2017 License Amendment Request - Safety Limit Minimum Critical Power Ratio Change, Non-Proprietary LR-N17-0124, Application to Revise Technical Specifications to Adopt TSTF-542, Reactor Pressure Vessel Water Inventory Control2017-09-21021 September 2017 Application to Revise Technical Specifications to Adopt TSTF-542, Reactor Pressure Vessel Water Inventory Control LR-N17-0088, Submittal of Hope Creek Generating Station Updated Final Safety Analysis Report, Revision 22, Hope Creek Technical Specification Bases Changes, 10CFR54.37(b) Review Results for Hope Creek and Pseg Nuclear LLC Quality Assurance Topical Re2017-05-0909 May 2017 Submittal of Hope Creek Generating Station Updated Final Safety Analysis Report, Revision 22, Hope Creek Technical Specification Bases Changes, 10CFR54.37(b) Review Results for Hope Creek and Pseg Nuclear LLC Quality Assurance Topical Repor LR-N17-0088, Enclosure 3: Hope Creek Generating Station Technical Specification Bases as of May 9, 20172017-05-0909 May 2017 Enclosure 3: Hope Creek Generating Station Technical Specification Bases as of May 9, 2017 ML17157B2652017-05-0909 May 2017 Submittal of Hope Creek Generating Station Updated Final Safety Analysis Report, Revision 22, Hope Creek Technical Specification Bases Changes, 10CFR54.37(b) Review Results for Hope Creek and PSEG Nuclear LLC Quality Assurance Topical Repor LR-N16-0066, License Amendment Request to Permit Operability of Low Pressure Coolant Injection While Aligned to Shutdown Cooling2016-06-17017 June 2016 License Amendment Request to Permit Operability of Low Pressure Coolant Injection While Aligned to Shutdown Cooling LR-N15-0178, Hope Creek - License Amendment Request, Digital Power Range Neutron Monitoring (Prnm) System Upgrade2015-09-21021 September 2015 Hope Creek - License Amendment Request, Digital Power Range Neutron Monitoring (Prnm) System Upgrade ML15265A2242015-09-21021 September 2015 License Amendment Request, Digital Power Range Neutron Monitoring (Prnm) System Upgrade LR-N13-0155, License Amendment Request to Relocate the Flood Protection Technical Specification to the Technical Requirements Manual2013-09-0505 September 2013 License Amendment Request to Relocate the Flood Protection Technical Specification to the Technical Requirements Manual ML1118615602011-07-28028 July 2011 And Salem Nuclear Generating Station, Unit Nos. 1 and 2, License Amendment, Issuance of Amendments Approval of Cyber Security Plan LR-N11-0068, Application for Technical Specification Change TSTF-477, Revision 3, Add Action for Two Inoperable Control Room AC Subsystems to the Technical Specifications Using Consolidated Line Item Improvement Process2011-02-28028 February 2011 Application for Technical Specification Change TSTF-477, Revision 3, Add Action for Two Inoperable Control Room AC Subsystems to the Technical Specifications Using Consolidated Line Item Improvement Process ML1100503992010-10-14014 October 2010 Attachment 4 to LR-N10-0355, Hope Creek Generating Station, Emergency Action Level Technical Bases Supporting Documents (Cd with Paper Index) ML1100504022010-10-14014 October 2010 Attachment 2 to LR-N10-0355, Hope Creek Generating Station, Emergency Action Level Technical Bases Document (Clean Version) ML1100503752010-10-14014 October 2010 Attachment 1 to LR-N10-0355, Hope Creek Generating Station, Emergency Action Level Technical Bases Document (Strike-out Version) LR-N10-0355, Attachment 1 to LR-N10-0355, Hope Creek Generating Station, Emergency Action Level Technical Bases Document (Strike-out Version)2010-10-14014 October 2010 Attachment 1 to LR-N10-0355, Hope Creek Generating Station, Emergency Action Level Technical Bases Document (Strike-out Version) ML1100503982010-10-14014 October 2010 Attachment 3 to LR-N10-0355, Hope Creek Generating Station, Emergency Action Level Comparison Matrix LR-N10-0355, Attachment 3 to LR-N10-0355, Hope Creek Generating Station, Emergency Action Level Comparison Matrix2010-10-14014 October 2010 Attachment 3 to LR-N10-0355, Hope Creek Generating Station, Emergency Action Level Comparison Matrix LR-N10-0355, Hope Creek, CY-AA-170-500, Revision 0, Meteorological Monitoring System Calibration and Maintenance2010-10-14014 October 2010 Hope Creek, CY-AA-170-500, Revision 0, Meteorological Monitoring System Calibration and Maintenance ML1100504152010-10-14014 October 2010 CY-AA-170-500, Revision 0, Meteorological Monitoring System Calibration and Maintenance LR-N10-0355, Attachment 2 to LR-N10-0355, Hope Creek Generating Station, Emergency Action Level Technical Bases Document (Clean Version)2010-10-14014 October 2010 Attachment 2 to LR-N10-0355, Hope Creek Generating Station, Emergency Action Level Technical Bases Document (Clean Version) LR-N10-0355, Attachment 4 to LR-N10-0355, Hope Creek Generating Station, Emergency Action Level Technical Bases Supporting Documents (Cd with Paper Index)2010-10-14014 October 2010 Attachment 4 to LR-N10-0355, Hope Creek Generating Station, Emergency Action Level Technical Bases Supporting Documents (Cd with Paper Index) ML1025802422010-09-0808 September 2010 License Amendment Request H10-01:, Application for Technical Specification Change Regarding Risk-Informed Justification for the Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled Program ML1100505182010-08-24024 August 2010 HC.OP-AB.ZZ-0150(Q), Rev. 6, 125VDC System Malfunction LR-N10-0355, Hope Creek, HC.OP-AB.ZZ-0150(Q), Rev. 6, 125VDC System Malfunction2010-08-24024 August 2010 Hope Creek, HC.OP-AB.ZZ-0150(Q), Rev. 6, 125VDC System Malfunction ML1100505002010-07-13013 July 2010 HC.OP-AB.HVAC-0002(Q), Rev. 7, Control Room Environment LR-N10-0355, Hope Creek, HC.OP-AB.HVAC-0002(Q), Rev. 7, Control Room Environment2010-07-13013 July 2010 Hope Creek, HC.OP-AB.HVAC-0002(Q), Rev. 7, Control Room Environment ML1100505162010-06-24024 June 2010 HC.OP-AB.RPV-0009(Q), Rev. 7, Shutdown Cooling LR-N10-0355, Hope Creek, HC.OP-AB.RPV-0009(Q), Rev. 7, Shutdown Cooling2010-06-24024 June 2010 Hope Creek, HC.OP-AB.RPV-0009(Q), Rev. 7, Shutdown Cooling LR-N10-0355, Hope Creek, HC.OP-AB.CONT-0002(Q), Rev. 9, Containment2010-05-0303 May 2010 Hope Creek, HC.OP-AB.CONT-0002(Q), Rev. 9, Containment ML1100504772010-05-0303 May 2010 HC.OP-AB.CONT-0002(Q), Rev. 9, Containment ML1100505052010-04-21021 April 2010 HC.OP-AB.MISC-0002(Q), Rev. 10, Crids/Overhead Annunciators/Ppc Computer LR-N10-0355, Hope Creek, HC.OP-AB.RPV-0003(Q), Rev. 21, Recirculation System/Power Oscillations2010-04-21021 April 2010 Hope Creek, HC.OP-AB.RPV-0003(Q), Rev. 21, Recirculation System/Power Oscillations ML1100505062010-04-21021 April 2010 HC.OP-AB.RPV-0003(Q), Rev. 21, Recirculation System/Power Oscillations LR-N10-0355, Hope Creek, HC.OP-AB.MISC-0002(Q), Rev. 10, Crids/Overhead Annunciators/Ppc Computer2010-04-21021 April 2010 Hope Creek, HC.OP-AB.MISC-0002(Q), Rev. 10, Crids/Overhead Annunciators/Ppc Computer LR-N10-0355, Hope Creek, Offsite Dose Calculation Manual, Revision 252010-04-16016 April 2010 Hope Creek, Offsite Dose Calculation Manual, Revision 25 ML1100504172010-04-16016 April 2010 Offsite Dose Calculation Manual, Revision 25 ML1100504742010-03-17017 March 2010 HC.IC-GP.BB-0003(Q) - Rev. 17, Nuclear Boiler - Nondivisional Channel L-11683/B21-N027 Rx Cavity Flood Up Level/Rx Shutdown Range Level Setup 2024-10-17 Category:Bases Change MONTHYEARLR-N23-0024, Submittal of Hope Creek Generating Station Technical Specification Bases Changes2023-03-29029 March 2023
[Table view]Submittal of Hope Creek Generating Station Technical Specification Bases Changes LR-N21-0078, Hope and Creek Generating Station, Supplement to License Amendment Request to Revise Technical Specifications (TS) to Delete Definitions Found in 10 CFR Part 20 and Delete Figures of the Site and Surrounding Areas from TS2021-11-18018 November 2021 Hope and Creek Generating Station, Supplement to License Amendment Request to Revise Technical Specifications (TS) to Delete Definitions Found in 10 CFR Part 20 and Delete Figures of the Site and Surrounding Areas from TS LR-N21-0079, Submittal of Hope Creek Generating Station Technical Specification Bases Changes2021-11-0303 November 2021 Submittal of Hope Creek Generating Station Technical Specification Bases Changes LR-N20-0060, Application to Revise Technical Specifications to Adopt TSTF-582, Reactor Pressure Vessel Water Inventory Control (RPV WIC) Enhancements2020-09-29029 September 2020 Application to Revise Technical Specifications to Adopt TSTF-582, Reactor Pressure Vessel Water Inventory Control (RPV WIC) Enhancements ML20142A5412020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Section 16, Technical Specifications LR-N20-0033, Submittal of Hope Creek Generating Station Technical Specification Bases Changes2020-05-15015 May 2020 Submittal of Hope Creek Generating Station Technical Specification Bases Changes ML19058A2212019-02-27027 February 2019 Application to Revise Technical Specifications to Adopt TSTF-546, Revise APRM Channel Adjustment Surveillance Requirement LR-N18-0127, Application to Revise Technical Specifications to Adopt TSTF-546, Revise APRM Channel Adjustment Surveillance Requirement2019-02-27027 February 2019 Application to Revise Technical Specifications to Adopt TSTF-546, Revise APRM Channel Adjustment Surveillance Requirement LR-N18-0013, License Amendment Request (LAR) to Amend the Hope Creek Technical Specifications (TS) to Revise Action for Inoperable Emergency Diesel Generator (EDG) a or B2018-03-28028 March 2018 License Amendment Request (LAR) to Amend the Hope Creek Technical Specifications (TS) to Revise Action for Inoperable Emergency Diesel Generator (EDG) a or B LR-N18-0011, Supplement to License Amendment Request- Safety Limit Minimum Critical Power Ratio Change. Includes GNF-004N5379-R1-NP, GNF Additional Information Regarding the Requested Changes to the Technical Specification SLMCPR2018-01-22022 January 2018 Supplement to License Amendment Request- Safety Limit Minimum Critical Power Ratio Change. Includes GNF-004N5379-R1-NP, GNF Additional Information Regarding the Requested Changes to the Technical Specification SLMCPR LR-N17-0163, License Amendment Request - Safety Limit Minimum Critical Power Ratio Change, Non-Proprietary2017-11-0909 November 2017 License Amendment Request - Safety Limit Minimum Critical Power Ratio Change, Non-Proprietary LR-N17-0088, Enclosure 3: Hope Creek Generating Station Technical Specification Bases as of May 9, 20172017-05-0909 May 2017 Enclosure 3: Hope Creek Generating Station Technical Specification Bases as of May 9, 2017 LR-N17-0088, Submittal of Hope Creek Generating Station Updated Final Safety Analysis Report, Revision 22, Hope Creek Technical Specification Bases Changes, 10CFR54.37(b) Review Results for Hope Creek and Pseg Nuclear LLC Quality Assurance Topical Re2017-05-0909 May 2017 Submittal of Hope Creek Generating Station Updated Final Safety Analysis Report, Revision 22, Hope Creek Technical Specification Bases Changes, 10CFR54.37(b) Review Results for Hope Creek and Pseg Nuclear LLC Quality Assurance Topical Repor ML17157B2652017-05-0909 May 2017 Submittal of Hope Creek Generating Station Updated Final Safety Analysis Report, Revision 22, Hope Creek Technical Specification Bases Changes, 10CFR54.37(b) Review Results for Hope Creek and PSEG Nuclear LLC Quality Assurance Topical Repor LR-N16-0066, License Amendment Request to Permit Operability of Low Pressure Coolant Injection While Aligned to Shutdown Cooling2016-06-17017 June 2016 License Amendment Request to Permit Operability of Low Pressure Coolant Injection While Aligned to Shutdown Cooling ML15265A2242015-09-21021 September 2015 License Amendment Request, Digital Power Range Neutron Monitoring (Prnm) System Upgrade LR-N15-0178, Hope Creek - License Amendment Request, Digital Power Range Neutron Monitoring (Prnm) System Upgrade2015-09-21021 September 2015 Hope Creek - License Amendment Request, Digital Power Range Neutron Monitoring (Prnm) System Upgrade LR-N13-0155, License Amendment Request to Relocate the Flood Protection Technical Specification to the Technical Requirements Manual2013-09-0505 September 2013 License Amendment Request to Relocate the Flood Protection Technical Specification to the Technical Requirements Manual LR-N11-0068, Application for Technical Specification Change TSTF-477, Revision 3, Add Action for Two Inoperable Control Room AC Subsystems to the Technical Specifications Using Consolidated Line Item Improvement Process2011-02-28028 February 2011 Application for Technical Specification Change TSTF-477, Revision 3, Add Action for Two Inoperable Control Room AC Subsystems to the Technical Specifications Using Consolidated Line Item Improvement Process LR-N10-0355, Attachment 2 to LR-N10-0355, Hope Creek Generating Station, Emergency Action Level Technical Bases Document (Clean Version)2010-10-14014 October 2010 Attachment 2 to LR-N10-0355, Hope Creek Generating Station, Emergency Action Level Technical Bases Document (Clean Version) LR-N10-0355, Attachment 4 to LR-N10-0355, Hope Creek Generating Station, Emergency Action Level Technical Bases Supporting Documents (Cd with Paper Index)2010-10-14014 October 2010 Attachment 4 to LR-N10-0355, Hope Creek Generating Station, Emergency Action Level Technical Bases Supporting Documents (Cd with Paper Index) ML1100504152010-10-14014 October 2010 CY-AA-170-500, Revision 0, Meteorological Monitoring System Calibration and Maintenance ML1100503992010-10-14014 October 2010 Attachment 4 to LR-N10-0355, Hope Creek Generating Station, Emergency Action Level Technical Bases Supporting Documents (Cd with Paper Index) LR-N10-0355, Attachment 3 to LR-N10-0355, Hope Creek Generating Station, Emergency Action Level Comparison Matrix2010-10-14014 October 2010 Attachment 3 to LR-N10-0355, Hope Creek Generating Station, Emergency Action Level Comparison Matrix ML1100503982010-10-14014 October 2010 Attachment 3 to LR-N10-0355, Hope Creek Generating Station, Emergency Action Level Comparison Matrix LR-N10-0355, Attachment 1 to LR-N10-0355, Hope Creek Generating Station, Emergency Action Level Technical Bases Document (Strike-out Version)2010-10-14014 October 2010 Attachment 1 to LR-N10-0355, Hope Creek Generating Station, Emergency Action Level Technical Bases Document (Strike-out Version) ML1100504022010-10-14014 October 2010 Attachment 2 to LR-N10-0355, Hope Creek Generating Station, Emergency Action Level Technical Bases Document (Clean Version) ML1100503752010-10-14014 October 2010 Attachment 1 to LR-N10-0355, Hope Creek Generating Station, Emergency Action Level Technical Bases Document (Strike-out Version) LR-N10-0355, Hope Creek, CY-AA-170-500, Revision 0, Meteorological Monitoring System Calibration and Maintenance2010-10-14014 October 2010 Hope Creek, CY-AA-170-500, Revision 0, Meteorological Monitoring System Calibration and Maintenance ML1025802422010-09-0808 September 2010 License Amendment Request H10-01:, Application for Technical Specification Change Regarding Risk-Informed Justification for the Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled Program ML1100505182010-08-24024 August 2010 HC.OP-AB.ZZ-0150(Q), Rev. 6, 125VDC System Malfunction LR-N10-0355, Hope Creek, HC.OP-AB.ZZ-0150(Q), Rev. 6, 125VDC System Malfunction2010-08-24024 August 2010 Hope Creek, HC.OP-AB.ZZ-0150(Q), Rev. 6, 125VDC System Malfunction LR-N10-0355, Hope Creek, HC.OP-AB.HVAC-0002(Q), Rev. 7, Control Room Environment2010-07-13013 July 2010 Hope Creek, HC.OP-AB.HVAC-0002(Q), Rev. 7, Control Room Environment ML1100505002010-07-13013 July 2010 HC.OP-AB.HVAC-0002(Q), Rev. 7, Control Room Environment LR-N10-0355, Hope Creek, HC.OP-AB.RPV-0009(Q), Rev. 7, Shutdown Cooling2010-06-24024 June 2010 Hope Creek, HC.OP-AB.RPV-0009(Q), Rev. 7, Shutdown Cooling ML1100505162010-06-24024 June 2010 HC.OP-AB.RPV-0009(Q), Rev. 7, Shutdown Cooling ML1100504772010-05-0303 May 2010 HC.OP-AB.CONT-0002(Q), Rev. 9, Containment LR-N10-0355, Hope Creek, HC.OP-AB.CONT-0002(Q), Rev. 9, Containment2010-05-0303 May 2010 Hope Creek, HC.OP-AB.CONT-0002(Q), Rev. 9, Containment ML1100505052010-04-21021 April 2010 HC.OP-AB.MISC-0002(Q), Rev. 10, Crids/Overhead Annunciators/Ppc Computer LR-N10-0355, Hope Creek, HC.OP-AB.MISC-0002(Q), Rev. 10, Crids/Overhead Annunciators/Ppc Computer2010-04-21021 April 2010 Hope Creek, HC.OP-AB.MISC-0002(Q), Rev. 10, Crids/Overhead Annunciators/Ppc Computer ML1100505062010-04-21021 April 2010 HC.OP-AB.RPV-0003(Q), Rev. 21, Recirculation System/Power Oscillations LR-N10-0355, Hope Creek, HC.OP-AB.RPV-0003(Q), Rev. 21, Recirculation System/Power Oscillations2010-04-21021 April 2010 Hope Creek, HC.OP-AB.RPV-0003(Q), Rev. 21, Recirculation System/Power Oscillations ML1100504172010-04-16016 April 2010 Offsite Dose Calculation Manual, Revision 25 LR-N10-0355, Hope Creek, Offsite Dose Calculation Manual, Revision 252010-04-16016 April 2010 Hope Creek, Offsite Dose Calculation Manual, Revision 25 ML1100504742010-03-17017 March 2010 HC.IC-GP.BB-0003(Q) - Rev. 17, Nuclear Boiler - Nondivisional Channel L-11683/B21-N027 Rx Cavity Flood Up Level/Rx Shutdown Range Level Setup LR-N10-0355, Hope Creek, HC.IC-GP.BB-0003(Q) - Rev. 17, Nuclear Boiler - Nondivisional Channel L-11683/B21-N027 Rx Cavity Flood Up Level/Rx Shutdown Range Level Setup2010-03-17017 March 2010 Hope Creek, HC.IC-GP.BB-0003(Q) - Rev. 17, Nuclear Boiler - Nondivisional Channel L-11683/B21-N027 Rx Cavity Flood Up Level/Rx Shutdown Range Level Setup ML1100505022010-03-0505 March 2010 HC.OP-AB.MISC-0001(Q), Rev. 15, Acts of Nature LR-N10-0355, Hope Creek, HC.OP-AB.MISC-0001(Q), Rev. 15, Acts of Nature2010-03-0505 March 2010 Hope Creek, HC.OP-AB.MISC-0001(Q), Rev. 15, Acts of Nature ML1100504992009-09-0909 September 2009 HC.OP-AB.COOL-0004(Q), Rev. 4, Fuel Pool Cooling LR-N10-0355, Hope Creek, HC.OP-AB.COOL-0004(Q), Rev. 4, Fuel Pool Cooling2009-09-0909 September 2009 Hope Creek, HC.OP-AB.COOL-0004(Q), Rev. 4, Fuel Pool Cooling 2023-03-29 Category:Updated Final Safety Analysis Report (UFSAR) MONTHYEARLR-N23-0027, Updated Final Safety Analysis Report, Rev. 26,2023-04-13013 April 2023
[Table view]Updated Final Safety Analysis Report, Rev. 26, ML23103A3232023-04-13013 April 2023 Submittal of Updated Final Safety Analysis Report, Rev. 26, Summary of Revised Regulatory Commitments for Hope Creek, Summary of Changes to PSEG Nuclear LLC, Quality Assurance Topical Report, NO-AA-10, Rev. 89 LR-N22-0086, – Unit 1 and Unit 2, Updated Final Safety Analysis Report, Revision 332022-10-24024 October 2022 – Unit 1 and Unit 2, Updated Final Safety Analysis Report, Revision 33 ML22298A0542022-10-24024 October 2022 – Units 1 and 2, Hope Creek Generating Station, Submittal of Updated Final Safety Analysis Report, Revision 33, 10 CFR 71.106 Review Results and 10 CFR 54.37(b) Review Results LR-N21-0081, Submittal of Updated Final Safety Analysis Report, Revision 25, Summary of Revised Regulatory Commitments2021-11-15015 November 2021 Submittal of Updated Final Safety Analysis Report, Revision 25, Summary of Revised Regulatory Commitments LR-N21-0046, Submittal of Salem Generating Station Updated Final Safety Analysis Report, Revision 32, Summary of Revised Regulatory Commitments for Salem, 10 CFR 71.106 Review Results and 10 CFR 54.37(b) Review Results for Salem2021-06-17017 June 2021 Submittal of Salem Generating Station Updated Final Safety Analysis Report, Revision 32, Summary of Revised Regulatory Commitments for Salem, 10 CFR 71.106 Review Results and 10 CFR 54.37(b) Review Results for Salem ML20142A5492020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Section 6, Engineered Safety Features ML20142A5302020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Section 1, Introduction & General Description of Plant ML20142A5242020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Appendix 3A, Computer Programs Used in Structural Analysis & Design ML20142A5422020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Section 17, Quality Assurance ML20142A5222020-05-21021 May 2020 Submittal of Updated Final Safety Analysis Report, Revision 24, Summary of Revised Regulatory Commitments and 10 CFR 54.37(b) Review Results ML20142A5312020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Section 3, Design of Structures, Components, Equipment and Systems LR-N20-0036, 4 to Updated Final Safety Analysis Report, Section 15, Accident Analyses2020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Section 15, Accident Analyses ML20142A5272020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Appendix 13A Through Appendix 13L Intentionally Deleted ML20142A5482020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Section 3.6, Protection Against Dynamic Effects Associated with the Postulated Rupture of Piping ML20142A5392020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Section 13, Conduct of Operation ML20142A5252020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Revision 24, Appendix 5A, Compliance with 10CFR50, Appendix G & Appendix H ML20142A5332020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Section 5, Reactor Coolant System & Connected Systems ML20142A5402020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Section 14, Initial Test Program ML20142A5432020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Section 18, Human Factors Engineering ML20142A5352020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Section 8, Electric Power ML20142A5232020-05-21021 May 2020 Updated Final Safety Analysis Report, Revision 24, Master Table of Contents and List of Current Pages ML20142A5532020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Section 12, Radiation Protection ML20142A5262020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Appendix 6A, Negative Pressure Design Evaluation ML20142A5372020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Section 10, Steam and Power Conversion System ML20142A5412020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Section 16, Technical Specifications ML20142A5462020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Appendix 9A, Appendix R Comparison ML20142A5322020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Section 4, Reactor ML20142A5282020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Appendix 15A, Purpose ML20142A5342020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Section 7, Instrumentation and Controls ML20142A5522020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Section 2, Site Characteristics ML20142A5382020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Section 11, Radioactive Waste Management ML20142A5292020-05-21021 May 2020 4 to Updated Final Safety Analysis Report, Appendix a, Supplement ML19360A0872019-12-0505 December 2019 Submittal of Revision 31 to Updated Final Safety Analysis Report and Technical Specification Bases Changes & Quality Assurance Topical Report, NO-AA-10, Rev. 88 LR-N18-0123, Submittal of Hope Creek Generating Station, Revision 23 to Updated Final Safety Analysis Report2018-11-12012 November 2018 Submittal of Hope Creek Generating Station, Revision 23 to Updated Final Safety Analysis Report ML18334A1502018-11-12012 November 2018 3 to Updated Final Safety Analysis Report, Appendix a, License Renewal Final Safety Analysis Report Supplement ML18334A1492018-11-12012 November 2018 3 to Updated Final Safety Analysis Report, Section 18, Human Factors Engineering ML18334A1452018-11-12012 November 2018 3 to Updated Final Safety Analysis Report, Section 15, Accident Analyses ML18334A1362018-11-12012 November 2018 3 to Updated Final Safety Analysis Report, Section 7, Instrumentation and Controls ML18334A1412018-11-12012 November 2018 3 to Updated Final Safety Analysis Report, Section 11, Radioactive Waste Management ML18334A1462018-11-12012 November 2018 3 to Updated Final Safety Analysis Report, Section 16, Technical Specifications ML18334A1482018-11-12012 November 2018 3 to Updated Final Safety Analysis Report, Section 17, Quality Assurance ML18334A1382018-11-12012 November 2018 3 to Updated Final Safety Analysis Report, Section 8, Electric Power ML18334A1422018-11-12012 November 2018 3 to Updated Final Safety Analysis Report, Section 12, Radiation Protection ML18334A1252018-11-12012 November 2018 3 to Updated Final Safety Analysis Report, Section 2, Site Characteristics ML18334A1282018-11-12012 November 2018 3 to Updated Final Safety Analysis Report, Section 4, Reactor ML18334A1442018-11-12012 November 2018 3 to Updated Final Safety Analysis Report, Section 14, Initial Test Program ML18334A1402018-11-12012 November 2018 3 to Updated Final Safety Analysis Report, Section 10, Steam and Power Conversion System ML18334A1432018-11-12012 November 2018 3 to Updated Final Safety Analysis Report, Section 13, Conduct of Operation ML18334A1302018-11-12012 November 2018 3 to Updated Final Safety Analysis Report, Section 5, Reactor Coolant System and Connected Systems 2023-04-13 |
Text
Section 16.1 16.2 HCGS-UFSAR SECTION 16 TECHNICAL SPECIFICATIONS TABLE OF CONTENTS Ttt1e PRELIMINARY TECHNICAL SPECIFICATIONS PROPOSED FINAL TECHNICAL SPECIFICATIONS 16.2-1 16-i Revision 0 April 11, 1988
16.1 PRELIMINARY TECHNICAL SPECIFICATIONS This section is not applicable to the Hope Creek Generating Station (HCGS) Final Safety Analysis Report (FSAR).
16.1-1 HCGS-UFSAR Revision 0 April 11, 1988
16.2 PROPOSED FINAL TECHNICAL SPECIFICATIONS Proposed draft Technical Specifications for Hope Creek Generating Station were issued by the USNRC dated June 28, 1985.
The HCGS Technical Specifications were issued for proof and review by the USNRC on September 30, 1985.
The final Technical Specifications will be issued as Appendix A to the Facility Operating License for Hope Creek Generating Station.
16.2-1 HCGS-UFSAR Revision 0 April 11, 1988