Semantic search

Jump to navigation Jump to search
Condition
Printout selection
Options
Parameters [
limit:

The maximum number of results to return
offset:

The offset of the first result
link:

Show values as links
headers:

Display the headers/property names
mainlabel:

The label to give to the main page name
intro:

The text to display before the query results, if there are any
outro:

The text to display after the query results, if there are any
searchlabel:

Text for continuing the search
default:

The text to display if there are no query results
class:

An additional CSS class to set for the table
transpose:

Display table headers vertically and results horizontally
sep:

The separator between results
prefix:

Control display of namespace in printouts
Sort options
Delete
Add sorting condition
 Issue dateTitleTopic
ML20086E43727 June 1974AO 74-10:on 740626,HPCI Inverter Tripped,Rendering HPCI Sys Inoperable.Cause Not Stated.Inverter Replaced
ML20086E4603 July 1974AO 74-09:in 740625,movements of LPCI Loop Break Detection Logic Differential Pressure Indicating Switches 2-129B & 2-129C Found Sticking,Causing Pointer to Log Input Pressure. Caused by Frequent Switch Actuation
ML20086E47326 June 1974AO 74-09:on 740625,movements of LPCI Loop Break Detection Logic Differential Pressure Indicating Switches 2-129B & 2-129C Sluggish,Causing Pointer to Lag Input Pressure.Switch 2-129B Replaced & 2-129C Placed in Trip Condition
ML20086E50013 June 1974AO 74-08:on 740525,water Discovered in Ventilation Ducting & in Instrument Penetrations at Biological Shield.Caused by Leak on Control Rod Drive Hydraulic Sys Return Line to Reactor Vessel,Due to Stress Corrosion CrackingHydrostatic
Liquid penetrant
ML20086E5764 June 1974AO 74-08:detailed Rept & Analysis Including Appropriate Corrective Measures Taken Re 740526 Incident Will Be Submitted within 20 Days of Occurrence
ML20086E58328 May 1974AO 74-08:on 740525,water Leakage Discovered Along Reactor Vessel Wall.Caused by Leak on Control Rod Drive Hydraulic Sys Return Line to Reactor Vessel.Engineering Review & Assessment Underway
ML20086E63615 May 1974AO 74-07:on 740509,spike Observed on Plant Stack Gas Recorder,Resulting in Stack Release Peak Greater than Allowed by Tech Specs.Caused by Steam Packing Exhauster Operation
ML20086E63910 May 1974AO 74-07:on 740509,spike Observed on Plant Stack Gas Recorder,Resulting in Stack Release Peak Greater than Allowed by Tech Specs.Cause Not Stated
ML20086E65225 April 1974AO 74-06:on 740418,both Access Doors to North Entrance to Reactor Bldg Found Partially Open.Caused by Personnel Failing to Verify Closure.Design Adequacy Under Review
ML20086E66419 April 1974AO 74-06:on 740418,both Access Doors to North Entrance to Reactor Bldg Found Open.Caused by Personnel Failure to Verify Closure.Methods to Assure Closure Underway
ML20086E67711 March 1974AO 74-05:on 740304,LPCI Loop a Valve V10-25A Failed to Open When Control Switch Placed in Open Position.Caused by Burned Out Valve Motor.Motor Replaced
ML20086E6965 March 1974AO 74-05:on 740304,LPCI Valve V10-25A Failed to Open When Control Switch Placed in Open Position.Caused by Tripped Motor Breaker & Unusually Warm Motor.Motor Replaced
ML20086E7131 March 1974AO 74-04:on 740223,MSIV Rv 2-71B Failed to Open at Required Setpoint.Indirectly Caused by Approved vendor-recommended Mods to Certain Relief Valve Internals.Procedure Revised
ML20086E72425 February 1974AO 74-04:on 740223,MSIV Rv 2-71B Failed to Open at Required Setpoint.Cause Under Investigation
ML20086E73211 February 1974AO 74-03:on 740204,LPCI Differential Pressure Indicating Switch 2-137B Failed to Indicate Properly Upon Isolation from Normal Sys Pressure W/Bypass Valve Open.Caused by Improper Sensor over-range Stop Setting.Sensors CalibrOvertravel
ML20086E7474 February 1974AO 74-03:on 740204,LPCI Differential Pressure Indicating Switch 2-137B Failed to Indicate Properly Upon Isolation from Normal Sys Pressure W/Bypass Valve Open.Cause Not Stated.Sensor Replaced
ML20086E7547 February 1974AO 74-02:on 740131,core Spray Sys Valve CS-11A Failed to Open When Control Switch Placed in Open Position.Caused by burned-out Valve Motor.Motor Replaced
ML20086E7631 February 1974AO 74-02:on 740131,core Spray Sys Valve CS-11A Failed to Open When Control Switch Placed in Open Position.Cause Not Stated.Surveillance Testing Completed & Sys Aligned to Standby Mode
ML20086E78231 January 1974AO 74-01:on 740124,reactor Scrammed,Resulting from Turbine Trip Causing Automatic Closure of All But One Msiv.Valve 2-80C Failed to Close Due to Failure of Pneumatic Pilot Valve to Actuate.Valve Assembly Returned to Vendor for Insp
ML20086E79025 January 1974AO 74-01:on 740124,reactor Scrammed Due to Turbine Trip, Causing Automatic Closure of All But One Msiv.Cause of Valve 2-80C Failure Not Stated
ML20086E81326 December 1973AO 73-35:on 731219,MSIV Relay 5A-K3C Failed to Energize During Monthly MSIV Functional Test.Caused by Limit Switch Actuating Arm Being in Wrong Position.Arm Manually Reset
ML20086E82620 December 1973AO 75-35:on 731219,MSIV Relay 5A-K3C Failed to Energize During Monthly MSIV Functional Test.Caused by Mispositioned Limit Switch Actuating Arm.Arm Manually Reset
ML20086E83527 December 1973AO 73-34:on 731217,station Svc Water Pump a 4-kV Breaker Stationary Auxiliary Switch Assembly Rear Mounting Tie Bolt Found Disengaged from Mounting Plate.Caused by Improper Bolt Tightening During Factory Assembly
ML20086E84019 December 1973AO 73-34:on 731217,station Svc Water Pump a 4-kV Breaker Stationary Auxiliary Switch Assembly Rear Mounting Tie Bolt Found Disengaged.Bolt Tightened
ML20086H16626 January 1973AO 50-271/72-19:on 721227,internal Fault on Startup Transformer Resulted in Loss of Normal Power Onsite.Caused by Failure of Safety Valve a to Lift.Pilot Valve Internals Will Be Replaced & Replacement Transformers Installed
ML20086H17028 December 1972AO 50-271/72-18:on 721222,containment Victoreen Air Monitor Pump Failed.Total RCS Leakage Ascertained Daily Until 721227.Pump Repair Completed & Sys Restored to Full Operation
ML20086H17228 December 1972AO 50-271/72-17:on 721222,during Monthly HPCI Pump Surveillance Test,Gasket on Gland Seal Exhaust Condenser Failed.Caused by Overpressurization of Condenser Due to Improper Setting of HPCI PCV23-50.Valve Reset
ML20086H17622 December 1972AO 50-271/72-17:on 721222,during Monthly HPCI Pump Surveillance Test,Gasket on Gland Seal Exhaust Condenser Failed.Replacement of Gasket Initiated & Cooler Repaired
ML20086H18121 December 1972AO 50-271/72-15:on 721219,during HPCI Sys Surveillance,Hpci Steam Line High Differential Pressure Switch DPIS 23-77 Tripped at 200 Inches of Water.Sensor Immediately Reset & Verified
ML20086H18620 December 1972AO 50-271/72-15:on 721219,HPCI Steamline High Differential Pressure Switch DPS 23-77 Tripped at 200 Inches of Water. Sensor Immediately Reset & Verified within Limits
ML20086H1904 December 1972AO 50-271/72-14:on 821204,during Core Spray Sys Surveillance,Reactor Pressure Switch Ps 2-3-52B Actuated at Less than 335 Psig.Switch Immediately Reset & Verified
ML20086H21210 November 1972AO 50-271/72-13:on 721109,during Sampling of Outside Radwaste Tanks,Total Activity of Tanks Found to Be 7.296 Ci, Exceeding Tech Spec Limit of 0.3 Ci.Caused by High Xenon Content in Water.Tanks Recycled & Restored on 721110
ML20086H2228 November 1972AO 50-271/72-10:on 721101,scram Discharge Vol High Water Level Switch Lsh 3-231C Failed to Actuate at Tech Spec Limit of 24 Gallons.Caused by Initial Corrosion within Sys.Float Chamber Flushed & Switch Verified
ML20086H2252 November 1972AO 50-271/72-10:on 721101,scram Discharge Vol High Water Level Switch Lsh 3-231C Failed to Actuate on High Water Level.Switch Chamber Immediately Cleaned & Flushed & Switch Verified
ML20086H2287 November 1972AO 50-271/72-12:on 721106,offgas Sample Chamber Isolated Intentionally to Permit Replacement of Chamber Flow Metering Valve.Valve Found Leaking.Valve Replaced & Three Fittings & One Union Tightened
ML20086H2461 November 1972AO 50-271/72-09:on 721026,two Barton Steam Line Differential Pressure Switches (DPIS 13-83 & 13-84) Failed to Actuate at Required Pressure of 180 Inches.Locking Devices May Be Causing Change.Switches Immediately Reset
ML20086H25027 October 1972AO 50-271/72-09:on 721026,two Barton Steam Line Differential Pressure Switches (DPIS 13-83 & 13-84) Actuated at 195 Inches,Exceeding Tech Spec Limit of 180 Inches.Switches Immediately Reset
ML20086H25525 August 1972AO 50-271/72-02:on 720801-08,airborne Contamination Levels within Containment Exceeded Average Level.Reactor Containment Required Due to Investigation of All Drywell Pressure Penetration taps.Open-ended Tees Plugged
ML20086H27026 October 1972AO 50-271/72-08:on 721020,during Automatic Depressurization Sys B Logic Test,Relief Valve Initiation Time Delay Relay 2E-K5B Failed to Energize in 120 S.Relay Immediately Reset
ML20086H27520 October 1972AO 50-271/72-08:on 731020,during Automatic Depressurization Sys B Logic Test,Relief Valve Initiation Time Delay Relay 2E-K5B Energized at 123 S,Exceeding Tech Spec Limit of 120 S.Relay Immediately Reset
ML20086H2883 October 1972AO 50-271/72-06:on 720928,steam Line High Differential Pressure Switch DPIS 13-84 Failed to Operate at Required 180 Inches of Water.Caused by Broken Common Lead.Lead Repaired
ML20086H29529 September 1972AO 50-271/72-06:on 720928,one Channel of Steam Line High D/P Isolation Failed to Operate at 180 Inches of Water.Caused by Broken Common Lead Between Conduit Fitting & Switch Terminal Board.Lead Repaired
ML20086H30029 September 1972Ao:On 720904,two Solenoid Operated Isolatation Valves in Torus Sampling Connection Found Not to Close on Isolation Signal.Caused by Valve Piston Binding.Piston Rings Removed, Valves Cleaned & Reassembled
ML20086H30317 August 1972AO 50-271/72-02:on 720801-08,during Investigation of All Drywell Pressure Penetration Caps,Reactor Coolant Temp Exceeded Tech Spec Limit.Caused by open-ended Tees.Tees in Sensing Lines Plugged
ML20086H30726 September 1972Ao:On 720803,RCIC Sys Turbine Steam Admission Valve RCIC-131 Failed.Caused by Piece of Metal Lodged on Valve Seat & Burned Out Motor.Metal Removed & Motor Replaced
ML20086H30922 September 1972AO 50-271/72-05:on 720921,supply Valve to Offgas Sample Chamber Closed.Caused by Inadvertent Shutting of Valve During Initial Operation of Air Ejector Sys.Procedures Revised to Assign locked-open ValvesTime of Discovery
Grab sample
ML20086H32119 October 1972AO 50-271/72-07:on 721010,alarm Annunicated in Main Control Room Indicating Leak in Bellows Assembly of Main Steam Relief Valve D.Caused by Residual Moisture Trapped in Tubing.Tubing Drained & Vented
ML20086H32411 October 1972AO 50-271/72-07:on 721010,alarm Annunciated in Main Control Room,Indicating Leak in Bellows Assembly of Main Steam Relief Valve D.Vendor Evaluating Problem
ML20086H33627 September 1972AO 50-271/72-04:on 720919,alarm Annunciated in Main Control Room Indicating Leak in Bellows of Main Steam Relief Valve. Failure Could Render One Relief Valve Incapable of Relieving Steam Pressure at Tech Spec Setpoint
ML20086H34322 September 1972AO 50-271/72-05:on 720921,supply Valve to Offgas Sample Chamber Found Closed.Offgas Activity Measured at 5 Mrm/Hr & Grab Sample of Air Ejectors Showed 145 Uci/S.Review Being ConductedGrab sample