AO 50-271/72-13:on 721109,during Sampling of Outside Radwaste Tanks,Total Activity of Tanks Found to Be 7.296 Ci, Exceeding Tech Spec Limit of 0.3 Ci.Caused by High Xenon Content in Water.Tanks Recycled & Restored on 721110
ML20086H212
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 11/10/1972
From: Rosalyn Jones
VERMONT YANKEE NUCLEAR POWER CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20086H216 List:
References
A-50-271-72-13, A0-50-271-72-13, VYV-2329, NUDOCS 8401160071
Download: ML20086H212 (2)


Text

r-O O

e t

VERMONT YANICEE NUOLEAR POWER CORPORATION L

SCVENTY GCVEN OROVC CTRECT RUT 1 AND, VEftMONT 03701 amv voi VYV-2329 P.O.DOX 1$7 VERNON, VERMONT 05354 Novernber 10, 1972 United States Atonic Energy Comission Directorate of Regulatory Operations, Region 1 970 Broad Street Newark, New Jersey 07102

REFERENCE:

Operating License DPR-28 Docket No. 50-271 Abnorraal Occurrence No. AO-72-13 Gentlenent As defined by Technical Specifications for the Vermont Yankee Nucicar Power Station, Section 6.7.A.c, we are reporting the following Abnorcal Occurrence as AO-72-13 and confirning our telephone conversation with your offico on this date.

At approxfinately 10:00 p.m. or, Hovenber 9, during routine surveillance satepling of the outside radwas.te tanko, the total activity of the threa tanks was found to be 7.296 Curica. This constituted a violation of Section 3.8.E of Technical Specifications, which establishes a limit of 0.3 Curies. The recetor van in the cold shutdown condition at the time of this occurrence.

This activity was almoot totally attributable to Xenon present in in the water (Xel33 - 86.78%, Xo135 - 11.05%). Tracen of the following isotopen were also present:

Cr51 _ o,93g 1131 - 0.89%

CoS8 - 0.12%

Zn65 - 0.09%

La140 - 0.05%

1133 - 0.03%

e401160071 00 i

PDR ADOCK 0 PDR

g. /

i s

Is j o

O,-

g ter.

p b

I i e UNITED STATES

  1. A ATOMIC ENERGY COMMISSION

+

I X

DivislON OF COMPLIANCE 201 645

[*'

f*

REGION I 5

Y 970 BROAD STREET si,7,, e

1 t

e

O O

VERMONT YANKEC NUCLCAR POWER CORPORATIOl Directorate of Regulatory Operations, Region I November 10, 1972 Page 2 The tanko vero recycled and the total activity contained in outoide radwaste storage was decreased to below the specified limit at approximately 9 30 a.m. on November 10.

Very truly yours, VEPf0NT 'ANKEE HUCLEAR POWER CORPORATION i

) j! &

l l

Robert F. Jc a

Plant Superintendent rus/rpb f