Semantic search

Jump to navigation Jump to search
Condition
Printout selection
Options
Parameters [
limit:

The maximum number of results to return
offset:

The offset of the first result
link:

Show values as links
headers:

Display the headers/property names
mainlabel:

The label to give to the main page name
intro:

The text to display before the query results, if there are any
outro:

The text to display after the query results, if there are any
searchlabel:

Text for continuing the search
default:

The text to display if there are no query results
class:

An additional CSS class to set for the table
transpose:

Display table headers vertically and results horizontally
sep:

The separator between results
prefix:

Control display of namespace in printouts
Sort options
Delete
Add sorting condition
 Issue dateTitleTopic
05000259/LER-2016-00121 June 2016Failure of 4kV Shutdown Board Normal Feeder Breaker Results in Actuations of Emergency Diesel Generators and Containment Isolation Valves
LER 16-001-00 for Browns Ferry, Unit 1, Regarding Failure of 4kV Shutdown Board Normal Feeder Breaker Results in Actuations of Emergency Diesel Generators and Containment Isolation Valves
Time of Discovery
05000259/LER-2016-00219 September 2016High Pressure Coolant Injection Safety System Functional Failure due to Inoperability of Primary Containment Isolation Valve
LER 16-002-00 for Browns Ferry, Unit 1, Regarding High Pressure Coolant Injection Safety System Functional Failure Due to Inoperability of Primary Containment Isolation Valve
Time of Discovery
Stroke time
Fuel cladding
05000259/LER-2017-00227 April 2017Unauthorized Firearm Introduced into the Protected Area
LER 17-002-00 for Browns Ferry, Unit 1, Regarding Unauthorized Firearm Introduced into the Protected Area
Safe Shutdown
Time of Discovery
Fitness for Duty
Contraband
05000260/LER-2015-00217 March 2016High Pressure Coolant Injection System Inoperable due to Manual Isolation of Steam Leak I
LER 15-002-01 for Browns Ferry, Unit 2, Regarding High Pressure Coolant Injection System Inoperable Due to Manual Isolation of Steam Leak
Safe Shutdown
Time of Discovery
Packing leak
Mission time
Past operability
05000260/LER-2016-00116 August 2016High Pressure Coolant Injection Safety System Functional Failure due to a Blown Fuse and a Failed Relay
LER 16-001-00 for Browns Ferry, Unit 2, Regarding High Pressure Coolant Injection Safety System Functional Failure Due to a Blown Fuse and a Failed Relay
Safe Shutdown
Time of Discovery
Test box
05000260/LER-2016-00213 September 2016High Pressure Coolant Injection System Failure Due To Stuck Contactor
LER 16-002-00 for Browns Ferry Nuclear Plant, Unit 2, Regarding High Pressure Coolant Injection System Failure Due To Stuck Contactor
Time of Discovery
Fuel cladding
05000260/LER-2017-00114 April 2017High Pressure Coolant Injection Safety System Functional Failure Due to a Blown Fuse
LER 17-001-00 for Browns Ferry, Unit 2, Regarding High Pressure Coolant Injection Safety System Functional Failure Due to a Blown Fuse
Safe Shutdown
Time of Discovery
05000260/LER-2017-00224 April 2017Inoperable Primary Containment Isolation Valve Resulting in Condition Prohibited by Technical Specifications
LER 17-002-00 for Browns Ferry, Unit 2, Regarding Inoperable Primary Containment Isolation Valve Resulting in Condition Prohibited by Technical Specifications
Safe Shutdown
Time of Discovery
Mission time
Past operability
05000260/LER-2017-00330 May 2017Manual Reactor Scram Initiated During Startup Due to Multiple Rods Inserting
LER 17-003-00 for Browns Ferry Nuclear Plant, Unit 2 Regarding Manual Reactor Scram Initiated During Startup Due to Multiple Rods Inserting
Safe Shutdown
Time of Discovery
Half scram
05000260/LER-2017-0047 July 2017Main Steam Relief Valves Lift Settings Outside of Technical Specifications Required Setpoints
LER 17-004-00 for Browns Ferry, Unit 2, Regarding Main Steam Relief Valves Lift Settings Outside of Technical Specifications Required Setpoints
Safe Shutdown
Time of Discovery
Coatings
Corrosion bonding
05000296/LER-2016-00121 March 2016Inoperable Residual Heat Removal Pump Results in Condition Prohibited by Technical Specifications and Safety System Functional Failure
LER 16-001-00 for Browns Ferry, Unit 3, Regarding Inoperable Residual Heat Removal Pump Results in Condition Prohibited by Technical Specifications and Safety System Functional Failure
Safe Shutdown
Time of Discovery
Past operability
Probabilistic Risk Assessment
05000296/LER-2016-00222 April 2016Improperly Installed Switch Results in Condition Prohibited by Technical Specifications
LER 16-002-00 for Browns Ferry Nuclear Plant, Unit 3, Regarding Improperly Installed Switch Results in Condition Prohibited by Technical Specifications
Safe Shutdown
Time of Discovery
Past operability
05000296/LER-2016-00325 April 2016Main Steam Isolation Valve Leaking in Excess of Technical Specification Requirements
LER 16-003-00 for Browns Ferry Nuclear Plant Unit 3 Regarding Main Steam Isolation Valve Leaking in Excess of Technical Specification Requirements
Safe Shutdown
05000296/LER-2016-0046 June 2016Main Steam Relief Valves Lift Settings Outside of Technical Specifications Required Setpoints
LER 16-004-00 for Browns Ferry, Unit 3, Regarding Main Steam Relief Valves Lift Settings Outside of Technical Specifications Required Setpoints
Safe Shutdown
Time of Discovery
Coatings
Corrosion bonding
05000296/LER-2016-00517 June 2016Automatic Depressurization System Valve Inoperability Exceeded Technical Specification Limits
LER 16-005-00 for Browns Ferry, Unit 3, Regarding Automatic Depressurization System Valve Inoperability Exceeded Technical Specification Limits
Safe Shutdown
Time of Discovery
Past operability
05000296/LER-2017-00131 October 2017Inoperable Residual Heat Removal Pump Results in Condition Prohibited by Technical Specifications
LER 17-001-00 for Browns Ferry Nuclear Plant, Unit 3, Regarding Inoperable Residual Heat Removal Pump Results in Condition Prohibited by Technical Specifications
Safe Shutdown
Time of Discovery
Past operability
Probabilistic Risk Assessment
Large early release frequency
05000296/LER-2017-00229 December 20174kV Shutdown Board Potential Transformer Primary Fuses Do Not Coordinate with Secondary Fuses
LER 17-002-00 for Browns Ferry Nuclear Plant, Unit 3 Regarding 4kV Shutdown Board Potential Transformer Primary Fuses Do Not Coordinate with Secondary Fuses
Safe Shutdown
Unanalyzed Condition
Time of Discovery
Large early release frequency
05000327/LER-2015-00422 January 2016Manual Reactor Trip due to Main Steam Isolation Valve Drifting in the Closed Direction
LER 15-004-00 for Sequoyah, Unit 1, Regarding Manual Reactor Trip Due to Main Steam Isolation Valve Drifting in the Closed Direction
Safe Shutdown
Post Accident Monitoring
05000327/LER-2016-00111 April 2016Automatic Safety Injection due to Low Steam Line Pressure on Loop 2 Main Steam
LER 16-001-00 for Sequoyah, Unit 1, Regarding Automatic Safety Injection due to Low Steam Line Pressure on Loop 2 Main Steam
Safe Shutdown
05000327/LER-2017-00126 April 2017Breached Door Renders Both Trains of the Auxiliary Building Gas Treatment System Inoperable
LER 17-001-00 for Sequoyah, Unit 1, Regarding Breached Door Renders Both Trains of the Auxiliary Building Gas Treatment System Inoperable
Safe Shutdown
Probabilistic Risk Assessment
Continuous fire watch
05000327/LER-2017-00214 July 2017Automatic Actuation of Emergency Diesel Generators Due to Loss of Power to 6.9kV Shutdown Board
LER 17-002-00 for Sequoyah, Unit 1, Regarding Automatic Actuation of Emergency Diesel Generators Due to Loss of Power to 6.9kV Shutdown Board
Safe Shutdown
05000327/LER-2021-001, & LER 2021-001-00 for Sequoyah Nuclear Plant, Units 1 & 2, Ice Bed Inoperable Due to Exceeding Surveillance Requirement Frequency22 September 2021& LER 2021-001-00 for Sequoyah Nuclear Plant, Units 1 & 2, Ice Bed Inoperable Due to Exceeding Surveillance Requirement FrequencySafe Shutdown
05000327/LER-2021-002, Letter Forwarding LER 2021-002-00 & LER 2021-001-00 for Sequoyah Nuclear Plant, Units 1 & 222 September 2021Letter Forwarding LER 2021-002-00 & LER 2021-001-00 for Sequoyah Nuclear Plant, Units 1 & 2
05000328/LER-2015-0026 January 2016Unanalyzed Condition Due To Inoperable Containment Recirculation Drains
LER 15-002-00 for Sequoyah, Unit 2, Regarding Unanalyzed Condition Due to Inoperable Containment Recirculation Drains
Safe Shutdown
Unanalyzed Condition
05000390/LER-2016-0019 March 2016Channel Mode Switch in Incorrect Position Renders Lower Containment Atmosphere Particulate Radiation Monitor Inoperable
LER 16-001-00 for Watts Bar, Unit 1, Regarding Channel Mode Switch in Incorrect Position Renders Lower Containment Atmosphere Particulate Radiation Monitor Inoperable
Safe Shutdown
Grab sample
05000390/LER-2016-00310 May 2016Technical Specification Surveillance Requirement Not Met During Emergency Core Cooling System Venting
LER 16-003-00 for Watts Bar, Unit 1, Regarding Technical Specification Surveillance Requirement Not Met During Emergency Core Cooling System Venting
Safe Shutdown
Probabilistic Risk Assessment
Temporary Modification
Missed surveillance
05000390/LER-2016-00423 May 2016Automatic Reactor Trip Due to Actuation of Over Temperature Delta Temperature Bistables
LER 16-004-00 for Watts Bar, Unit 1, Regarding Automatic Reactor Trip Due to Actuation of Over Temperature Delta Temperature Bistables
Safe Shutdown
05000390/LER-2016-00513 May 2016Both Trains of Unit 1 Emergency Gas Treatment System Inoperable During Unit 2 Testing
LER 16-005-00 for Watts Bar, Unit 1, Regarding Both Trains of Unit 1, Emergency Gas Treatment System Inoperable During Unit 2, Testing
Safe Shutdown
Stroke time
Safe Shutdown Earthquake
Past operability
05000390/LER-2016-00630 June 2016Undersized Room Cooler Fan Shaft Results in Loss of Centrifugal Charging Pump
LER 16-006-00 for Watts Bar, Unit 1, Regarding Undersized Room Cooler Fan Shaft Results in Loss of Centrifugal Charging Pump
Safe Shutdown
Mission time
Past operability
05000390/LER-2016-00720 June 2016Technical Specification Action Not Met for Rod Position Indication
LER 16-007-00 for Watts Bar Nuclear Plant, Unit 1 Regarding Technical Specification Action Not Met for Rod Position Indication
Safe Shutdown
Rod Drop Event
05000390/LER-2016-00815 July 2016Emergency Diesel Generator Manual Start Due to Loss of Voltage on the 6.9kV Shutdown Board 1B-B
LER 16-008-00 for Watts Bar, Unit 1, Regarding Emergency Diesel Generator Manual Start Due to Loss of Voltage on the 6.9kV Shutdown Board 1B-B
Safe Shutdown
Open Phase Condition
05000390/LER-2016-00915 July 2016Failure to Complete Surveillance Requirements Causes a Condition Prohibited by the Technical Specifications
LER 16-009-00 for Watts Bar, Unit 1, Regarding Failure to Complete Surveillance Requirements Causes Conditions Prohibited by the Technical Specifications
Missed surveillance
05000390/LER-2016-0108 August 2016Emergency Diesel Generator Crankcase Pressure Switches Not Analyzed to Withstand the Effects of a Tornado
LER-16-010-00 for Watts Bar Nuclear Plant, Units 1 and 2 Regarding Emergency Diesel Generator Crankcase Pressure Switches Not Analyzed to Withstand the Effects of a Tornado
Safe Shutdown
Unanalyzed Condition
05000390/LER-2016-0119 December 2016Loss of Centrifugal Charging Pump Due to Repeat Failure of Associated Room Cooler
LER 16-011-01 for Watts Bar Nuclear Plant, Unit 1 Regarding Loss of Centrifugal Charging Pump Due to Repeat Failure of Associated Room Cooler
Safe Shutdown
Mission time
Past operability
05000390/LER-2017-00114 February 2017Failure of Emergency Raw Cooling Water Pump Reverse Rotation Keys Represents Potential Common Cause Inoperability
Watts Bar, Units 1 and 2 - Cancellation of Licensee Event Report 390/2017-001 Related to Essential Raw Cooling Water Pump Reverse Rotation Keys Representing a Potential Common Cause lnoperability
Safe Shutdown
05000390/LER-2017-00222 February 2017Incorrectly Hung Clearance Leads to a Condition Prohibited by the Technical Specifications
LER 17-002-00 for Watts Bar Nuclear Plant, Unit 1, Regarding: Incorrectly Hung Clearance Leads to a Condition Prohibited by the Technical Specifications
Safe Shutdown
05000390/LER-2017-0033 March 2017Inadequate Operability Determination Leads to a Condition Prohibited by the Technical Specifications
LER 17-003-00 for Watts Bar, Unit 1, Regarding Inadequate Operability Determination Leads to a Condition Prohibited by the Technical Specifications
Safe Shutdown
Safe Shutdown Earthquake
Functionality Assessment
Pressure boundary leak
Through-Wall Leak
05000390/LER-2017-00431 August 2017Manual Reactor Trips Due to Failed Reactor Coolant Pump Power Transfer During Plant Startup
LER 17-004-01 for Watts Bar, Unit 1, Regarding Manual Reactor Trips Due to Failed Reactor Coolant Pump Power Transfer During Plant Startup
Safe Shutdown
Anticipated operational occurrence
05000390/LER-2017-00510 July 2017Isolation of the 1 B-B Safety Injection Pump Leads to Condition Prohibited by Technical Specifications
LER 17-005-00 for Watts Bar re Isolation of the 1B-B Safety Injection Pump Leads to a Condition Prohibited by Technical Specifications
Safe Shutdown
05000390/LER-2017-00631 July 2017Structural Degradation of 161 kV Line Pole Leads to a Condition Prohibited by Technical Specifications
LER 17-006-00 for Watts Bar, Unit 1, Regarding Structural Degradation of 161 kV Line Pole Leads to a Condition Prohibited by Technical Specifications
Safe Shutdown
05000390/LER-2017-0078 August 2017Multiple Unreported Potential Loss of Safety Function Events Associated with Inoperable Single Train Systems Due to Misinterpretation of Reporting Guidance
LER 17-007-00 for Watts Bar, Unit 1, Regarding Multiple Unreported Potential Loss of Safety Function Events Associated with Inoperable Single Train Systems Due to Misinterpretation of Reporting Guidance
Safe Shutdown
Rod Drop Event
05000390/LER-2017-00814 August 2017Shield Building Inoperability and Potential Loss of Safety Function Resulting from Spurious Equipment Operation
LER 17-008-00 for Watts Bar, Unit 1, Regarding Shield Building Inoperability and Potential Loss of Safety Function Resulting from Spurious Equipment Operation
Safe Shutdown
05000390/LER-2017-01010 October 2017Actuation of Turbine Driven Auxiliary Feedwater Pump Due to Loss of 6.9kV Shutdown Board
LER 17-010-00 for Watts Bar Nuclear Plant, Unit 1 Regarding Actuation of Turbine Driven Auxiliary Feedwater Pump Due to Loss of 6.9kV Shutdown Board
Safe Shutdown
05000390/LER-2017-01123 October 2017Failure to Enter Technical Specification 3.6.3 for Containment Isolation Valve
LER 17-011-00 for Watts Bar, Unit 1, Regarding Failure to Enter Technical Specification 3.6.3 for Containment lsolation Valve
Safe Shutdown
Time of Discovery
05000390/LER-2017-01223 October 2017Error in Plant Emergency Procedures Leads to a Condition Prohibited by the Technical Specifications
LER 17-012-00 for Watts Bar, Unit 1, Regarding Error in Plant Emergency Procedures Leads to a Condition Prohibited by the Technical Specifications
Safe Shutdown
Past operability
Probabilistic Risk Assessment
05000390/LER-2017-01324 January 20181 OF 5
LER 17-013-01 for Watts Bar Nuclear Plant, Units 1 and 2 Regarding Incorrectly Adjusted Auxiliary Building Gas Treatment System Damper Leads to a Condition Prohibited by Technical Specifications
Safe Shutdown
Safe Shutdown Earthquake
Past operability
Probabilistic Risk Assessment
05000390/LER-2017-01420 December 2017Main Control Room Boundary Door Left Open Leading to a Loss of Safety Function
LER 17-014-00 for Watts Bar, Unit 1, Regarding Main Control Room Boundary Door Left Open Leading to a Loss of Safety Function
Safe Shutdown
Probabilistic Risk Assessment
05000390/LER-2017-0158 January 2018Failure to Enter Limiting Condition of Operation Action Statement Results in a Condition Prohibited by Technical Specifications
LER 17-015-00 for Watts Bar, Units 1 and 2, Regarding Failure to Enter Limiting Condition of Operation Action Statement Results in a Condition Prohibited by Technical Specifications
Safe Shutdown
05000391/LER-2016-00113 June 2016Loss of Automatic Containment Isolation for the Steam Generator Blowdown Sampling Lines
LER 16-001-00 for Watts Bar, Unit 2, Regarding Loss of Automatic Containment Isolation for the Steam Generator Blowdown Sampling Lines
Safe Shutdown
05000391/LER-2016-00211 July 2016Turbine Driven Auxiliary Feedwater Pump Inoperable for Longer than Allowable Outage Time due to Turbine Speed Control Failure
LER 16-002-00 for Watts Bar, Unit 2, Regarding Turbine Driven Auxiliary Feedwater Pump Inoperable for Longer Than Allowable Outage Time Due to Turbine Speed Control Failure
Safe Shutdown
Past operability