IR 05000338/198601922 August 1986Partially Withheld Insp Repts 50-338/86-19 & 50-339/86-19 on 860728-0801 (Ref 10CFR2.790 & 73.21).No Violation or Deviation Noted.Major Areas Inspected:Security Sys Power Supply & Physical barrier-vital Areas
IR 05000338/198602023 September 1986Insp Repts 50-338/86-20 & 50-339/86-20 on 860804-0914.No Violation or Deviation Noted.Major Areas Inspected:Ler Followup,Monthly Maint & Surveillance Observations,Followup of Reactor Trip Event & ESF Sys WalkdownUnidentified leakage
IR 05000338/198602111 September 1986Insp Repts 50-338/86-21 & 50-339/86-21 on 860825-29.No Violations or Deviations Noted.Major Areas Inspected: Followup of Previously Identified Items & Plant Tour
IR 05000338/198602326 September 1986Insp Repts 50-338/86-23 & 50-339/86-23 on 860902-05.No Violation or Deviation Noted.Major Areas Inspected:Mods to Svc Water Intake Structure
IR 05000338/198602421 October 1986Insp Repts 50-338/86-24 & 50-339/86-24 on 860915-1012.No Violation or Deviation Noted.Major Areas Inspected:Plant Status,Licensee Action on Previous Enforcement Matters,Ler Followup & Monthly Maint ObservationUnidentified leakage
IR 05000338/19860252 December 1986Insp Repts 50-338/86-25 & 50-339/86-25 on 861013-1117. Violation Noted:Failure to Establish Adequate QC Measures to Ensure Proper Incorporation of Tech Spec AmendsPacking leak
Unidentified leakage
IR 05000338/198602612 December 1986Insp Repts 50-338/86-26 & 50-339/86-26 on 861103-06.No Violations or Deviations Noted.Major Areas Inspected: Licensee Action on Previous Open Items & Svc Water Reservoir ImprovementsNondestructive Examination
IR 05000338/198602712 December 1986Insp Repts 50-338/86-27 & 50-339/86-27 on 861111-21. Violation Noted:Failure to Establish,Implement & Maintain Procedures for Calibr of Alpha Survey InstrumentHigh Radiation Area
Job Performance Measure
Process Control Program
IR 05000338/198700213 March 1987Partially Withheld Insp Repts 50-338/87-02 & 50-339/87-02 on 870209-13 (Ref 10CFR2.790 & 73.21).No Violation Noted.Major Areas Inspected:Barriers in Vital Area,Security Sys Power Supply,Compensatory Measures & Detection Aids
IR 05000338/19870033 March 1987Insp Repts 50-338/87-03 & 50-339/87-03 on 870209-13.No Violations or Deviations Noted.Major Areas Inspected: Electrical Discipline W/Regards to Employee Concerns Identified to NRC
IR 05000338/198700431 March 1987Insp Repts 50-338/87-04 & 50-339/87-04 on 870220-0317.No Violations or Deviations Noted.Major Areas Inspected:Plant Status,Ler Followup,Review of Inspector Followup Items & Health Physics & Environ Qualification ProblemsBoric Acid
Grab sample
Offsite Dose Calculation Manual
IR 05000338/19870051 May 1987Insp Repts 50-338/87-05 & 50-339/87-05 on 870406-10.No Violations or Deviations Noted.Major Areas Inspected: Emergency Preparedness Program
IR 05000338/198700623 April 1987Insp Repts 50-338/87-06 & 50-339/87-06 on 870318-0416.No Violations or Deviations Noted.Major Areas Inspected:Plant Status,Licensee Action on Previous Enforcement Matters,Ler, Review of Inspector Followup Items & ESF WalkdownHigh Radiation Area
Hydrostatic
IR 05000338/198700720 April 1987Insp Repts 50-338/87-07 & 50-339/87-07 on 870330 & 0402-03. No Violations or Deviations Noted.Major Areas Inspected: Licensee Action on Previous Open Items,Svc Water Reservoir Improvements,Weld Insp & Review of Personnel Qualifications
IR 05000338/198701020 May 1987Insp Repts 50-338/87-10 & 50-339/87-10 on 870417-0512.No Violations or Deviations Noted.Major Areas Inspected:Plant Status,Unresolved Items,Ler Followup,Review of Inspector Followup Items & Monthly Maint ObservationUnanalyzed Condition
Hydrostatic
Finite Element Analysis
IR 05000338/19870112 July 1987Insp Repts 50-338/87-11 & 50-339/87-11 on 870608-12.No Violations or Deviations Noted.Major Areas Inspected: Selected Areas of Emergency Preparedness ProgramHealth Physics Network
Siren
IR 05000338/198701214 July 1987Insp Repts 50-338/87-12 & 50-339/87-12 on 870504-0605. Violations Noted.Major Areas Inspected:Inservice Insp Activities,Functional Testing of Hydraulic Snubbers,Flux Thimble Insp & Secondary Side Pipe Ultrasonic ExamNondestructive Examination
Liquid penetrant
IR 05000338/19870136 July 1987Insp Repts 50-338/87-13 & 50-339/87-13 on 870601-03.Major Areas Inspected:Licensee Action on Previous Enforcement Matters & Previously Identified Insp Findings
IR 05000338/198701613 July 1987Insp Repts 50-338/87-16 & 50-339/87-16 on 870608-11.No Violations or Deviations Noted.Major Areas Inspected:Review of Selected Reactor Engineering Procedures & Completion Status of Previously Identified Insp FindingsShutdown Margin
IR 05000338/198701722 June 1987Insp Repts 50-338/87-17 & 50-339/87-17 on 870608-12.No Violations or Deviations Noted.Major Areas Inspected:Plant ChemistryBoric Acid
Grab sample
IR 05000338/198701817 July 1987Insp Repts 50-338/87-18 & 50-339/87-18 on 870615-19.No Violations or Deviations Noted.Major Areas Inspected:Review of Radiographs & NDE Acceptance Documentation for Unit 1 Feedwater Replacement PipeweldsNondestructive Examination
Liquid penetrant
IR 05000338/19870191 September 1987Insp Repts 50-338/87-19 & 50-339/87-19 on 870617-0818. Violations Noted.Major Areas Inspected:Plant Status, Unresolved Items,Licensee Actions on Previous Enforcement Matters,Inspector Followup Items & LER Followup
IR 05000338/198702111 August 1987Insp Repts 50-338/87-21 & 50-339/87-21 on 870621-0710. Violations Noted.Major Areas Inspected:Introduction & General Description of Loss of Coolant Sys Inventory Event & Contributing Factors Which Complicated Event
IR 05000338/198702328 July 1987Insp Repts 50-338/87-23 & 50-339/87-23 on 870706-10.No Violations Noted.Major Areas Inspected:Security Plan & Implementing Procedures,Mgt Effectiveness & Security Organization.Details Withheld (Ref 10CFR2.790 & 73.21)
IR 05000338/198702421 August 1987Augmented Insp Team Repts 50-338/87-24 & 50-339/87-24 on 870715-0814.Three Violations & One Unresolved Item Noted. Major Areas Inspected:Licensee Actions Re Steam Generator Tube Failure in 870715Boric Acid
Grab sample
Nondestructive Examination
IR 05000338/198702528 September 1987Insp Repts 50-338/87-25 & 50-339/87-27 on 870831-0904.No Violations or Deviations Noted.Major Areas Inspected: Radiation Protection,Including Organizational & Mgt Controls & Internal Exposure ControlHigh Radiation Area
Locked High Radiation Area
Overexposure
IR 05000338/198702716 September 1987Insp Repts 50-338/87-27 & 50-339/87-26 on 870817-21.No Violations or Deviations Noted.Major Areas Inspected:Snubber Surveillance Program,Ieb 85-001,IEIN 85-045 & Licensee Action on Previous Insp Findings
IR 05000338/198702827 August 1987Insp Rept 50-338/87-28 on 870810-14.No Violations Noted. Major Areas Inspected:Eddy Current Exam of Steam Generator Tubing Following 870715 Tube Rupture in Steam Generator C, Including Exam Plan & Procedures & Personnel QualificationsNondestructive Examination
IR 05000338/19870291 October 1987Insp Repts 50-338/87-29 & 50-339/87-29 on 870819-0917.No Violations or Deviations Noted.Major Areas Inspected:Plant Status,Licensee Action on Previous Enforcement Matters,Ler Followup,Maint & Surveillance Observation & ESF WalkdownOverexposure
IR 05000338/19870303 September 1987Insp Repts 50-338/87-30 & 50-339/87-30 on 870825-27. Violations Noted.Major Areas Inspected:Review of Events Associated W/Potential Exposure of Skin of Whole Body of Worker in Excess of Regulatory LimitsOverexposure
IR 05000338/198703118 September 1987Insp Repts 50-338/87-31 & 50-339/87-31 on 870831-0904.No Violations or Deviations Noted.Major Areas Inspected:Unit 2 Inservice Insp,Unit 1 Ongoing Eddy Current Exam of Steam Generator Tubing,Nrc Bulletin 87-001 & Info Notice 87-036Hydrostatic
Nondestructive Examination
Liquid penetrant
IR 05000338/198703317 November 1987Insp Repts 50-338/87-33 & 50-339/87-33 on 870928-1002.No Violations or Deviations Noted.Major Areas Inspected:Review of Containment Isolation Sys Local Leak Rate Program, Including Review of Test Procedures & Valve Alignments
IR 05000338/19870344 November 1987Insp Repts 50-338/87-34 & 50-339/87-34 on 870918-1019.No Violations or Deviations Noted W/Exception of One Licensee Identified Violation.Major Areas Inspected:Plant Status, Unresolved Items,Esf Walkdown & LER Followup
IR 05000338/198703523 October 1987Insp Repts 50-338/87-35 & 50-339/87-35 on 870928-1001.No Violations or Deviations Noted.Major Areas Inspected: Installation of Downcomer Flow Resistance Plates in Steam GeneratorsLoop seal
IR 05000338/198703628 December 1987Insp Repts 50-338/87-36 & 50-339/87-36 on 871020-1119. Violations Noted.Major Areas Inspected:Plant Status, Unresolved Items,Ler Followup,Esf Walkdown,Verification of Containment Integrity & SecurityShutdown Margin
Fuel cladding
IR 05000338/198703721 December 1987Insp Repts 50-338/87-37 & 50-339/87-37 on 871019-23. Violations & Deviation Noted.Major Areas Inspected:Fire ProtectionSafe Shutdown
Fire Barrier
Emergency Lighting
Exemption Request
Fire Protection Program
IR 05000338/19870416 January 1988Insp Repts 50-338/87-41 & 50-339/87-41 on 871214-18.No Violation or Deviation Noted.Major Areas Inspected:Inservice Insp & Testing of Pumps & Valves & Closing of Open ItemsStroke time
VT-2
IR 05000338/19880052 May 1988Insp Repts 50-338/88-05 & 50-339/88-05 on 880224-0405. Violations Noted.Major Areas Inspected:Plant Status,Licensee Action on Previous Enforcement Matters,Review of Inspector Followup Items & Monthly Maint ObservationBoric Acid
Packing leak
Stroke time
Unidentified leakage
IR 05000338/198800828 April 1988Insp Repts 50-338/88-08 & 50-339/88-08 on 880404-08.No Violations or Deviation Noted.Major Areas Inspected:Complex Surveillance & IE Bulletins FollowupsLoop seal
Stroke time
IR 05000338/19880102 May 1988Insp Repts 50-338/88-10 & 50-339/88-10 on 880404-08.No Violations or Deviations Noted.Major Areas Inspected: post-refueling Startup Test,Shutdown Margin Surveillance, RCS Leakage Surveillance & Thermal Power MonitoringShutdown Margin
Unidentified leakage
IR 05000338/198801128 June 1988Insp Repts 50-338/88-11 & 50-339/88-11 on 880406-0513.No Violations Noted.Major Areas Inspected:Plant Status, Unresolved Items,Ler,Review of Inspector follow-up Items & Monthly Maint ObservationPacking leak
Stroke time
IR 05000338/19880126 July 1988Insp Repts 50-338/88-12 & 50-339/88-12 on 880420-22.No Violations or Deviations Noted.Major Areas Inspected:Snubber Surveillance Program & Followup on Licensee Action on Previous Insp Findings
IR 05000338/198801313 September 1988Insp Repts 50-338/88-13 & 50-339/88-13 on 880718-22. Violation Noted.Major Areas Inspected:Triennial post-fire Safe Shutdown Capability Reverification & Assessment, Including App R Compliance & post-fire Shutdown CapabilitySafe Shutdown
Fire Barrier
Coatings
Emergency Lighting
Exemption Request
Continuous fire watch
Fire Protection Program
IR 05000338/198801418 August 1988Insp Repts 50-338/88-14 & 50-339/88-14 on 880627-30.No Violations or Deviations Noted.Major Areas Inspected: Emergency Response Facility & Equipment,Interviews W/Util Personnel & Equipment for Emergency Response OrganizationEmergency Lighting
IR 05000338/198801523 June 1988Insp Repts 50-338/88-15 & 50-338/88-15 on 880524-27.No Violations or Deviations Noted.Major Areas Inspected: Licensee Actions Taken Due to Svc Water Sys Fouling in Recirculation Spray HXs
IR 05000338/19880178 July 1988Insp Repts 50-338/88-17 & 50-339/88-17 on 880606-10.No Violations or Deviations Noted.Major Areas Inspected:Review & Evaluation of Inservice Insp Data from Unit 2,1987 Refueling Outage & Maint Records Review of Coolant PumpBoric Acid
Stroke time
Missed surveillance
IR 05000338/198801927 June 1988Insp Rept 50-338/88-19 & 50-339/88-19 on 880606-10.No Violations or Deviations Noted.Major Areas Inspected:Records & Repts,Physical Barrier & Detection Aids on Vital Areas & Protected Areas & Physical Protection Safeguards InfoSafeguards Contingency Plan
IR 05000338/198802112 August 1988Insp Repts 50-338/88-21 & 50-339/88-21 on 880611-0715.No Violations or Deviations Noted.Major Areas Inspected: Plant Status,Ler,Review of Inspector Followup Items,Monthly Maint Observation & Operator Safety VerificationBoric Acid
IR 05000338/198802317 August 1988Partially Withheld Insp Rept 50-338/88-23 & 50-339/88-23 on 880803-05 (Ref 10CFR2.790).No Violations Noted.Major Areas Inspected:Testing & Maint,Physical barriers-protected Area, Security Sys Power Supply & Access control-personnel
IR 05000338/19880257 September 1988Insp Repts 50-338/88-25 & 50-339/88-25 on 880808-12.No Violations,Deviations or Program Weaknesses Noted.Major Areas Inspected:Plant Chemistry,Chemical Corrosion & Pipe Wall ThinningBoric Acid