Revision 2 Pages Unit 2 COLR 9708050254 9'70730 PDR ADQCK 05000528

'DR P

CORE OI EmxING uMnS RZI ORr PALO VERDE NUCLEAR GENERATING STATION (PVNGS)

UNIT 2 CYCLE 7 Revision 2 Page 1 of 23

~ ~

t PVNGS UNIT 2 CYCLE 7 CORK OPERATING LIMITSREPORT Table of Contents l Revision 2

~Descri tion Revision ¹ ~Pa e Cover Page Table of Contents Affected Technical Specifications CORE Operating Limits 3.1.1.1 Shutdown Margin - Reactor Trip Breakers Open 3.1.1.2 Shutdown Margin - Reactor Trip Breakers Closed 3.1.1.3 Moderator Temperature Coefficient 3.1.2.7 Boron Dilution Alarms 3.1.3.1 Movable Control Assemblies - CEA Position 3.1.3.6 Regulating CEA Insertion Limits 3.1.3.7 Part Length CEA Insertion Limits 3.2.1 Linear Heat Rate 3.2.3 Azimuthal Power Tilt - Tq 3.2.4 DNBR Margin 3.2.7 Axial Shape Index 3.9.1 Boron Concentration (Mode 6)

List of Figures Figure 3.1.1.1-1 Shutdown Margin Versus Cold Leg Temperature 7a Reactor Trip Breakers Open Figure 3.1.1.2-1 Shutdown Margin Versus Cold Leg Temperature Reactor Trip Breakers Closed Figure 3.1.1.3-1 MTC Acceptable Operation, Modes 1 and 2 Figure 3.1.3.1-1 Core Power Limit After CEA Deviation 10 Figure 3.1.3.6-1 CEA Insertion Limits Versus Thermal Power (COLSS in Service)

Figure 3.1.3.6-2 CEA Insertion Limits Versus Thermal Power 12 (COLSS Out of Service)

Figure 3.1.3.7-1 Part Length CEA Insertion Limits Versus Thermal Power 0 13 Page 2 of 23

~ ~

t PVNGS UNIT 2 CYCLE 7 CORE OPERATING LIMITS RE<PORT Table of Contents (Continued) t Revision 2

~Deecri <ion Revision 0 ~Pa e Figure 3.2.3-1 Azimuthal Power Tilt Versus Thermal Power 14 (COLSS in Service)

Figure 3.2.4-1 COLSS DNBR Operating Limit Allowance for Both 15 CEAC's Inoperable Figure 3.2.4-2 DNBR Margin Operating Limit Based on the Core 16 Protection Calculators (COLSS Out of Service, CEAC's Operable)

Figure 3.2.4-3 DNBR Margin Operating Limit Based on the Core 17 Protection Calculators (COLSS Out of Service, CEAC's Inoperable)

List of Tables Table 3.1.2.7-1 Required Monitoring Frequencies for Backup Boron 19 Dilution Detection as a Function of Operating Charging Pumps and Plant Operational Modes for Keff> 0.98 Table 3.1.2.7-2 Required Monitoring Frequencies for Backup Boron 20 Dilution Detection as a Function of Operating Charging Pumps and Plant Operational Modes for 0.98 > Keff > 0.97 Table 3.1.2.7-3 Required Monitoring Frequencies for Backup Boron 21 Dilution Detection as a Function of Operating Charging Pumps and Plant Operational Modes for 0.97 > Keff > 0.96 Table 3.1.2.7-4 Required Monitoring Frequencies for Backup Boron 22 Dilution Detection as a Function of Operating Charging Pumps and Plant Operational Modes for 0.96 > Keff > 0.95 Table 3.1.2.7-5 Required Monitoring Frequencies for Backup Boron 23 Dilution Detection as a Function of Operating Charging Pumps

(

and Plant Operational Modes for Keff 0.95 Page 3 of 23

~ ~

Revision 2 PVNGS UNIT 2 CYCLE 7 CORE OPERATING LIMITS REPORT RK PERATIN I IMIT, - TIN KD 3.1.1.3 - Moderator Tem erature CoefFicient The moderator temperature coefficient (MTC) shall be within the area of Acceptable Operation shown in Figure 3.1.1.3-1.

8.1.2.7 - Boron Dilution Alarms With one or both start-up channel high neutron flux alarms inoperable, the RCS boron concentration shall be determined at the applicable monitoring frequency specified in Tables 3.1.2.7-1 through 3.1.2.7-5.

3.1.3.1 - Movable ntrol Assemblies - CEA Position With one or more full-length or part-length CEAs misaligned from any other CEAs in its group by more than 6.6 inches, the minimum required MODES 1 and 2 core power reduction is specified in Figure 3.1.3.1-1.

3.1.3.6 - Re atin EA Insertion Limits One or more CEAC's OPERABLE: With COLSS IN SERVICE, regulation CEA groups shall be limited to the withdrawal sequence and to the insertion limits shown in Figure 3.1.3.6-1; with COLSS OUT OF SERVICE, regulation CEA groups shall be limited to the withdrawal sequence and to the insertion limits shown in Figure 3.1.3.6-2.

8.1.3.7- Part Len h EA Insertion Limits One or more CEAC's OPERABLE: The part length CEA groups shall be limited to the insertion limits shown in Figure 3.1.3.7-1.

8.2.1 - Linear Heat Rate The linear heat rate limit of 18.3 kW/ft shall be maintained.

Page 5 of 23