MONTHYEARML23100A1072023-04-10010 April 2023 Framatome Part 21 Report Re Erroneous Change of State for Circuit Breaker ML23229A0052022-02-11011 February 2022 Ametek Solidstate Controls, Final 10CFR21 Report of a Potential Defect, Vishay Diodes. Reference Interim Report ML21092A129 Issued April 1, 2021 ML21260A0072021-09-0909 September 2021 Ametek Solidstate Controls, Notification of Potential Defect - 10CFR Part 21 Report Re Omron Timer Relay ML21092A1292021-04-0101 April 2021 Ametek Solidstate Controls - Notification of Potential Defect ML20366A0472020-11-18018 November 2020 Curtiss-Wright 10 CFR Part 21 Notification for SF-1154 Hydraulic Fluid Batch 17BLVS293 ML20049A0752020-02-11011 February 2020 C&D Technologies, Inc. -10 CFR Part 21 Evaluation Regarding Container Failure in KCR-07 Batteries ML19347A4262019-12-10010 December 2019 General Atomics - Reportable Occurrence Under 10CFR21: Reported Failure in Analog High Range Radiation Monitor (RP-2C) ML19317D0932019-10-25025 October 2019 Engine Systems, Inc., 10CFR21 Reporting of Defects and Non-Compliance - Engine Systems, Inc. Report No. 10 CFR21-0127, Rev. 0, Emd Fuel Injectors - Seized Plunger and Bushing ML19190A0442019-06-0707 June 2019 10 CFR Part 21 Reporting of Defects for Introl Positioner 890265-010 - Cw SAS Initial Report No. 10CFR21-48 ML19121A1552019-04-15015 April 2019 Curtiss-Wright Nuclear Division, Enertech - 10 CFR Part 21 Notification for SF-1154 Hydraulic Fluid ML19002A2042018-12-21021 December 2018 to Engine Systems, Inc., Part 21 Report Re Emd Fuel and Soakback Pumps - Potentially Undertorqued Cover Bolts ML18353A4282018-11-30030 November 2018 Engine Systems, Inc., 10CFR21-0123, Rev. 0, for a 10CFR21 Reportable Condition on Emd Fuel and Soakback Pumps ML17354A0262017-11-27027 November 2017 Paragon Energy Solutions 10 CFR Part 21 Final Report of Potential Defect of Switch Assembly with OT-2 Homewood Products Corp Switch and Contact Block ML17179A3782017-06-0707 June 2017 TE Connectivity - Part 21 Transfer of Information TE-023 ML17114A0702017-04-13013 April 2017 Part 21 Notification - Identified Fisher 546S Electro-Pneumatic Transducers Standard Mounting Brackets Failed Seismic Testing Standards ML17081A4532017-03-20020 March 2017 Part 21 - Plastic Jar Dedication Sampling ML17026A4142017-01-20020 January 2017 C&D Technologies, Inc. - Part 21 - Plastic Jar Dedication Sampling ML16342A9782016-12-0202 December 2016 ATC Nuclear - Part 21 - Pawl Fasteners Failed to Provide Sufficient Structural Support ML16321A4512016-10-21021 October 2016 Part 21 Reporting of Defects and Noncompliance ML16294A2642016-10-18018 October 2016 Part 21 Report - Defective Current to Pressure Transducers ML16243A4722016-08-25025 August 2016 Part 21 Reporting of Defects and Noncompliance ML16139A8342016-05-10010 May 2016 Electroswitch - Transmittal of 10CFR Part 21 Reporting of Defects and Noncompliance Regarding Vendor Inspection of Electroswitch Corporation Docket No. 99900833 ML16098A4472016-03-21021 March 2016 Emerson Process Management, LLC - Part 21 Report Regarding Plug/Stem Assembly, Per Watts Bar ML16084A3022016-03-18018 March 2016 Emerson Process Management, LLC - Part 21 Report Regarding Groove Pin Dedication, Per Watts Bar ML15103A4852015-04-0707 April 2015 Itt Engineered Valves - 2nd Interim Report to the NRC of 10 CFR 21 Event 50285, Reported by Itt 07/18/14 Concerning M I Diaphragms, Customer Testing ML15099A0422015-04-0202 April 2015 Notification of Part 21 Report - Potentially Defective Pressure & Temperature Switches ML15099A0432015-04-0202 April 2015 Amendment to Event Number 50299, 10 CFR Part 21 Notification, Potentially Defective Pressure & Temperature Switches ML15049A4582015-02-0606 February 2015 Thermo Gamma-Metrics, LLC - Part 21 Report Regarding Shutdown Margin Monitor Environmental Qualification Noncompliance ML15014A0612015-01-0808 January 2015 Notification of Potential Part 21 Re Failure of Sbm Type Switches ML14337A0942014-11-24024 November 2014 Notification of Potential Part 21 - Lack of Proper Power Supply Indication ML14329A0632014-11-19019 November 2014 Notification of Potential Part 21 Re Lack of Proper Power Supply Indication ML14274A0522014-09-22022 September 2014 Final Report 10CFR Part 21 Evaluation Regarding Misaligned Separators in LCR-25 Standby Batteries, Revision 1 - Original Letter Did Not Include the List of Affected Utilities ML14261A1502014-09-17017 September 2014 Interim Report to the NRC of 10 CFR 21 Event 50285, Reported by Itt 07/18/14 Concerning M1 Diaphragms, Customer Testing ML14213A0992014-07-24024 July 2014 Notification of Part 21 Report - Potentially Defective Pressure & Temperature Switches IR 05000391/20140012014-06-23023 June 2014 Construction Deficiency Report 50-391/2014-01 - Potential Opening of Littelfuse Part Number FLAS005.T Fuses - Final Report ML14174A0422014-06-23023 June 2014 Construction Deficiency Report 50-391/2014-01 - Potential Opening of Littelfuse Part Number FLAS005.T Fuses - Final Report ML14160A7832014-06-0303 June 2014 Part 21 Report Regarding Watts Bar, Unit 2, Potentially Defective Fuses Installed ML14364A1682014-06-0202 June 2014 Flowserve Corp., Vermont, Formal Evaluation of Deviations Reported - Notification of Defect - Watts Bar II ML14034A1882014-01-23023 January 2014 Part 21 Report Regarding Nonconformance of an Electrical Tubular Water Heater ML14042A2002014-01-21021 January 2014 Part 21 Report Regarding Non-Conformance of an Electrical Tubular Water Heater ML13256A1392013-09-13013 September 2013 Notification of Potential Part 21 Report Re Watts Bar Nuclear Plant, Unit 1 - Dresser Masoneilan Valve Stem/Plug Assemblies Found Out-of-Tolerance ML13234A1162013-08-16016 August 2013 Notification of Potential Part 21 Report - Auxiliary Feedwater Level Control Value Stem/Plug Assembly Out of Tolerance ML13204A3812013-07-18018 July 2013 Construction Deficiency Report 50-391/2013-01 - Commercial Grade Dedication Program - Final Report IR 05000391/20130012013-07-18018 July 2013 Construction Deficiency Report 50-391/2013-01 - Commercial Grade Dedication Program - Final Report IR 05000391/20130022013-06-27027 June 2013 Construction Deficiency Report 50-391/2013-02 - Instrument Sense Line Slope Issue - Final Report ML13182A4602013-06-27027 June 2013 Construction Deficiency Report 50-391/2013-02 - Instrument Sense Line Slope Issue - Final Report ML13165A3422013-06-12012 June 2013 60-Day Interim Report Involving an Evaluation of a Design Change to Magne-Blast Circuit Breakers ML13161A3422013-06-0505 June 2013 ATC Nuclear, Interim Part 21 Report Involving Review of Seismic Testing Methodology ML13129A1762013-05-0606 May 2013 Construction Deficiency Report 50-391/2013-01 - Commercial Grade Dedication Program - Second Interim Report ML13091A3882013-03-28028 March 2013 Interim Part 21 Report Involving Review of Seismic Testing Methodology 2023-04-10
[Table view] |
Text
ENllllGY SOLlJTIONS November 27, 2017 Document Control Center U.S. Nuclear Regulatory Commission*
Washington, DC 20555
Subject:
IOCFR Part 21 Final Report Pursuant to 10CFR 21.2l(a)(2), Paragon ES is providing a final report of a potential defect of a Paragon Energy Solutions provided switch assembly with an OT-2 Homewood Products Corp. switch and contact blocks. The switch assembly is identified by TVA assigned Part Number OT2-45B640-25 l. The enclosure to this letter provides updated information.
If you have any questions or need additional information regarding this matter, please contact Ray Chalifoux at (865) 384-0124.
Sincerely,
~AU~-
Ray Chalifoux Vice President QA, Paragon ES 777 Emory Valley Rd* Oak Ridge, TN 37830
Enclosure p ./ / ./ \,
___ ar ago_n. Page 1 of2 ENERGY SOLUTlON\)
Final Report; Accession No. MLI 73 l1A904 (Log Number 2017-47-00) Interim Report (i) Name and address of the individual or individuals informing the Commission.
Ray Chalifoux Paragon Energy Solutions 777 Emory Valley Rd.
Oak Ridge, TN 37830 .
(ii) Identification of the basic component supplied that contains a potential defect.
PART NUMBER; OT2-45B640-251 SWITCH, MANUAL, QA 1, CONTROL, 3, 22 PIN, OT-2 SWITCH, WITH OT2V6W OPERATOR & CAM NO. 6, OPEN OR CLOSE
- OPIIN POSITIONS, SPRING RETURN TO CENTER (NOR), MOUNTED IN WESTINGHOUSE OR EQUAL M02 MODULE, CONFIGURED PER TVA DWG 2-45B640-251 (CIHS-063-0073A TO BE CLOSE* A AUTO
(iii) Identification of the firm supplying the basic component which fails to comply or contains a potential defect:
Paragon Energy Solutions (fon11erly ATC Nuclear) 777 Emory Valley Rd.
Oak Ridge, TN 37830 (iv) Nature of the potential defect.
The licensee has concluded that the contact chatk'f anomalous condition did not present: a substantial safety hazard for the installed switch.
Previous Interim Report Information Seismic qualification testing revealed contact block (CB) chatter> 2 milliseconds (msec) contrary to the acceptance requirements of the seismic test procedure developed for the activity. This switch has not been provided to the customer, however, a second suspect switch with a similar configuration and parts is installed in the customer's facility.
The condition is isolated to when OT2A CBs are configured in an altemating Nom1ally Open (NO)
/ Nonnally Closed (NC), NC/NO, NO/NC, and NC/NO. The CBs do not exhibit chatter when 3 or less CBs are configured this way. Also, the chatter is not exhibited when configmed in a NO/NC, NO/NC, continuing configuration. When the fourth CB is added to the switch assembly in an alternating configuration is when the contact chatter exceeds > 2 111sec.
Paragon Engineering requested TVA Engineering to provide a reduced spectra specific to the installed location for further evaluation. Paragon Engineering was not able to complete this activity within the 60-day period specified under 10 CPR Part 21.
777 Emory Valley Rd* Oak Ridge, TN 37830
Enclosure Final 10CFR21 Report Page2 of2 ENERGY 801..1.lTlONS (v) The date on which the information of such defect or failure to comply was obtained.
This is an update to an Interim Report that has been resolved by the licensee.
(vi) Suspect basic component, the number and location of these components in use at, supplied for, being supplied for, or may be supplied for, manufactm*ed, or being manufactured for one or more facilities or activities subject to the regulations in this part.
A total of (1) assembly as identified below has been provided.
TVAPO Facility Line Item Job No. Item ID 1184674 WattsBar2 1 15T2245 CQA80lB (vii) The corrective action which has been, is being, or will be taken; the name of the individual or organization responsible for the action; and the length of time that has been or will be taken to complete the action.
Paragon ES successfully completed qualification of a seismic specimen to the originally provided spectra using older vintage contact blocks. A reduced response spectra was requested from the licensee to verify that this condition did not present a substantial safety hazard for the existing installed switch.
The licensee alternatively completed an evaluation of the condition and determined a substantial safety hazard did not exist.
(viii) Any advice related to the potential defect or failure to comply about the facility, activity, or basic component that has been, is being, or will be given to purchasers or licensees.
Differences exist in the contact blocks that were procured from Homewood for the switch assemblies. It appears the OT2 contact blocks have undergone a change in the past few years. This was found when the current (newer) contact blocks were disassembled and compared piece-by-piece to older contact blocks (2010 vintage). There are no differences between the 2 blocks visually, but there is a difference in spring force and a difference in weight of the plunger.
The newer contact blocks have a slightly weaker spring force and a heavier plunger weight than the older contact blocks. These two differences have a combined effect in making the newer contact blocks more susceptfble to chatter. When the OEM was contacted about these differences, they communicated there had been no design changes.
777 Emory Valley Rd* Oak Ridge, TN 37830