ML12066A175

From kanterella
Revision as of 05:03, 30 April 2019 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search

Fourth Ten-Year Inservice Inspection Plan Request for Relief No. 11-ON-002
ML12066A175
Person / Time
Site: Oconee  Duke Energy icon.png
Issue date: 02/29/2012
From: Gillespie T P
Duke Energy Carolinas
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML12066A175 (308)


Text

{{#Wiki_filter:PkDuke EEnergyT. PRESTON GILLESPIE, JR.Vice President Oconee Nuclear Station Duke Energy ONO] VP / 7800 Rochester Hwy.Seneca, SC 29672 864-873-4478 864-873-4208 fax T. Gillespie@duke-energy. com February 29, 2012 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555

Subject:

Duke Energy Carolinas, LLC Oconee Nuclear Station Units 2 and 3 Docket No. 50-270, -289 Fourth Ten-Year Inservice Inspection Plan Request for Relief No. 11-ON-002 Pursuant to 10 CFR 50.55a(g)(5)(iii), attached is a Request for Relief from the requirement to examine 100% of the volume specified by the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code), Section XI, Rules for Inservice Inspection of Nuclear Power Plant Components, 1998 Edition with 2000 Addenda (as modified by Code Case N-460).The attached Request for Relief 11-ON-002 is to allow Duke Energy to take credit for the enclosed Table 1 list of limited ultrasonic examinations on welds associated with various systems and components during Unit 2 EOC23 and Unit 3 EOC24 and Unit 3 EOC25 refueling outages. The ultrasonic examination coverage of the subject Unit 1, and 2 welds did not meet the 90% examination requirements of Code Case N-460. The obtainable volume coverage for weld examination is indicated on Attachments A, B and C of the relief request. Achievement of greater examination coverage for these welds is impractical due to piping/valve geometry and interferences. Therefore, Duke Energy requests that the NRC grant relief as authorized under 10 CFR 50.55(g)(6)(i). If there are any questions or further information is needed you may contact Corey Gray at (864)-873-6325. Sincerely, T Preston Gillespie Jr., Site Vice President Attachment A Attachment B Attachment C www. duke-energy. corn U. S. Nuclear Regulatory Commission February 29, 2012 Page 2 Xc w/att: Victor Mcree Region II Administrator U. S. Nuclear Regulatory Commission Marquis One Tower 245 Peachtree Center Ave., NE, Suite 1200 Atlanta, GA 30303-1257 John Stang Project Manager U. S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Mail Stop 0-8 G9A Washington, DC 20555 Xc w/o attachment Andy Sabisch NRC Senior Resident Inspector Oconee Nuclear Station Susan Jenkins Section Manager Division of Waste Management Bureau of Land and Waste Management SC Dept. of Health & Environment Control 2600 Bull St.Columbia, SC 29201 Relief Request 11 ON 002 1.0 Scope of Relief Request Relief is requested pursuant to 10 CFR 50.55a(g)(5)(iii) for welds listed in Table 1.These welds were required to be examined in accordance with Inservice Inspection Plans for the following Units.Oconee Nuclear Station -Unit 2 Fourth 10-Year Inservice Inspection Interval Interval Start Date: 09/09/2004 Oconee Nuclear Station -Unit 3 Fourth 10-Year Inservice Inspection Interval Interval Start Date: 1/2/2005 Table 1 Relief Oconee Examination Weld ID Item/Summary Examination Request Unit Performed Number Number Data Section Number (Refuelingq Number Outaqe)2.0 2 2EOC23 2-PZR- 02.B3.110.0012 See Attachment WP26-7 A Pages 1-10 3.0 2 2EOC23 2-PIB2-8 02.B9.111.0031 See Attachment A Pages 11-16 4.0 2 2EOC23 2-PIB1-8 02.B9.11.0058 See Attachment A Pages 17-24 5.0 2 2EOC23 2-53A-10-3 02.B9.11.0067 See Attachment A Pages 25-30 6.0 2 2EOC23 2LP-1 50- 02.C5.11.0005 See Attachment 17 A Pages 31-36 7.0 2 2EOC23 2LP-217-8 02.C5.11.0021 See Attachment A Pages 37-40 8.0 2 2EOC23 2-53A-9-16 02.C5.11.0025 See Attachment A Pages 41-46 9.0 2 2EOC23 2LP-189- 02.C5.11.0034 See Attachment 14 A Pages 47-53 Page 1 of 71 Relief Request 11 ON 002 10.0 2 2EOC23 2LP-215-17 02.C5.11.0036 See Attachment A Pages 54-58 11.0 2 2EOC23 2LP-218-23 02.C5.11.0067 See Attachment A Pages 59-62 12.0 2 2EOC23 2-51A 02.C5.21.0027 See Attachment 15 A Pages 63-68 13.0 2 2EOC23 2-51A 02.C5.21.0029 See Attachment 21 A Pages 69-72 14.0 2 2EOC23 2HP-222-2 02.C5.21.0031 See Attachment A Pages 73-75 15.0 2 2EOC23 2-51A 02.C5.21.0055 See Attachment 93 A Pages 76-79 16.0 2 2EOC23 2HP-221- 02.C5.21.0256 See Attachment 22 A Pages 80-81 17.0 3 3EOC24 3-PZR- 03.B3.110.0006 See Attachment WP26-4 B Pages 1-9 18.0 3 3EOC24 3-PZR- 03.B3.110.0007 See Attachment WP26-5 B Pages 10-18 19.0 3 3EOC24 3-PZR- 03.B3.110.0008 See Attachment WP26-6 B Pages 19-27 ,20.0 3 3EOC24 3-LDCA-IN-03.B3.150.0001 See Attachment 2V B Pages 28-36 21.0 3 3EOC24 3-LDCA- 03.B3.150.0002 See Attachment OUT-5V B Pages 37-45 22.0 3 3EOC24 3-PDAI-1 03.B9.11.0068 See Attachment B Pages 46-51 23.0 3 3EOC24 3-PDB2-1 03.B9.11.0074 See Attachment B Pages 52-57 24.0 3 3EOC24 3-51A 03.C5.21.0024 See Attachment 44 B Pages 58-61 25.0 3 3EOC25 N32389-3 PSI See Attachment WJ-32 C Pages 1-7 26.0 3 3EOC25 N32389-3 PSI See Attachment WJ-33 C Pages 8-15 27.0 3 3EOC25 N32389-3 PSI See Attachment WJ-35 C Pages 16-22 Page 2 of 71 Relief Request 11 ON 002 28.0 3 3EOC25 N32389-3 PSI See Attachment WJ-36 C Pages 23-29 29.0 3 3EOC25 3-PIA2-8 03.B9.11.0056 See Attachment C Pages 30-39 30.0 3 3EOC25 3-PIB1-8 03.B9.11.0060 See Attachment C Pages 40-49 31.0 3 3EOC25 3-PIB2-8 03.B9.11.0064 See Attachment C Pages 50-59 32.0 3 3EOC25 3-PDA2-1 03.B9.11.0070 See Attachment C Pages 60-69 33.0 3 3EOC25 3-PDBI-1 03.B9.11.0072 See Attachment C Pages 70-79 34.0 3 3EOC25 3HP-365- 03.C5.21.0034 See Attachment 40 C Pages 80-87 35.0 3 3EOC25 3HP-498- 03.C5.21.0066 See Attachment 14 C Pages 88-93 Page 3 of 71 Relief Request 11 ON 002 2.0 Weld #2-PZR-WP26-7 2.1. ASME Code Component(s) Affected Unit 2 Pressurizer Heater Belt Shell to Sampling Nozzle Weld, Weld #2-PZR-WP26-7, Summary Number 02.B3.1110.0012 2.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section XI, 1998 Edition through the 2000 Addenda 2.3. Applicable Code Requirement IWB-2500, Table IWB-2500-1, Examination Category B-D, Item Number B3.110 Fig. IWB-2500-7 (a), 100% Volume Coverage of Examination Volume A-B-C-D-E-F-G-H-I 2.4. Impracticality of Compliance The pressurizer Heater Belt shell material is carbon steel and the sampling nozzle material is carbon steel. This weld has a diameter of 5.750 inches and a wall thickness of 6.187 inches.Because of the weld configuration, the requirements of ASME Section V, Article 4, T-441.1.2(a), T-441.1.3, T-441.1.4, T-441.1.5 and T-441.1.6 could not be met. The aggregate coverage was calculated from the following base and weld metal scan results: Weld coverage using 350, 450& 600 shear waves for axial scans (S1, S2), and 35° & 450 shear waves for circ. scans (CW, CCW) obtained 17.2% coverage.Base material coverage using 350, 450& 600 shear wave for axial scans (SI) and 35°& 450 shear waves for circ. scans (CW, CCW)obtained 54.0% coverage.* 00 scan coverage obtained 37.5% coverage.* The aggregate coverage was calculated to be (17.2% + 54.0% +37.5%)/3 = 36.2%.The limitation was caused by the weld taper configuration created by the attachment of the sampling nozzle to the Heater Belt shell not allowing scanning from Surface 2. In order to scan all of the required volume for this weld, the upper shell to sampling nozzle attachment weld would have to be redesigned to allow scanning from both sides of the weld, which is impractical. Page 4 of 71 Relief Request 11 ON 002 The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. The achieved coverage did not meet the acceptance criteria of this Code Case.2.5. Proposed Alternative and Basis for Use No substitution alternative for this weld is available which would provide better coverage.2.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.2.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 02.B3.110.0012 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section XI, 1998 Edition with the 2000 Addenda.The system leakage test performed each refueling outage in accordance with Table IWB-2500-1; Examination Category B-P requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric and pressure test), Reactor Building Normal Sump monitoring provides additional assurance that, in the event that leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the pressure testing (VT-2) examinations required by Section Xl, and the leakage monitoring, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 5 of 71 Relief Request 11 ON 002 3.0 Weld #2-PIB2-8 3.1. ASME Code Component(s) Affected Unit 2 Reactor Coolant Pump 2B2 Casing Nozzle to Safe-End Weld, Weld#2-PIB2-8, Summary Number 02.B9.11.0031 3.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section Xl, 1998 Edition through the 2000 Addenda 3.3. Applicable Code Requirement IWB-2500, Table IWB-2500-1, Examination Category B-J, Item Number B9.11 Figure IWB-2500-8 (c), 100% Volume Coverage of Examination Volume C-D-E-F 3.4. Impracticality of Compliance This item is a cast stainless steel pump casing nozzle welded to a stainless steel safe end. This weld has a diameter of 33.50 inches and a wall thickness of 2.33 inches.Scanning requirements are described in 1OCFR.50.55a(b)(2)(xv) (A)(1). The aggregate coverage was calculated from the following:

  • 600 shear waves obtained 0% coverage in one axial direction (S1 -nozzle)0 600 shear waves obtained 50% coverage in one axial direction (S2 -pipe)0 450 shear waves obtained 50% coverage in one circ. directions (S3 -CW)0 450 shear waves obtained 50% coverage in one circ. directions (S4 -CCW)* The aggregate coverage was calculated to be (0% + 50% + 50% +50%)/4 = 37.5%.0 60' longitudinal waves obtained 47.3% supplemental coverage beyond the weld centerline in one axial direction (S2 -pipe). This is not included in the aggregate coverage.0 In addition, a best effort examination was performed in two axial directions (S1, S2) using 600 and 700 longitudinal waves to the extent possible in the upper 2/3 area of interest.The individual scan results are recorded on the form labeled "Determination of Percent Coverage for UT Examinations

-Pipe. The limitation was caused by the cast stainless material and the weld taper configuration created by the attachment of the nozzle to safe end configuration. In order to scan all of the required volume for this weld, the pump would have to be replaced with Page 6 of 71 Relief Request 11 ON 002 forged stainless steel and would have to be redesigned to allow scanning from both sides of the weld, which is impractical. The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. The achieved coverage did not meet the acceptance criteria of this Code Case.3.5. Proposed Alternative and Basis for Use No alternative examinations are planned for the weld during the current inspection interval. Radiography (RT) is not a desired option because RT is limited in the ability to detect expected degradation mechanisms such as thermal fatigue cracking and stress corrosion crack initiating at the pipe inside surface. Additionally, radiography has not been qualified through performance demonstration. 3.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.3.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 02.B9.11.0031 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section Xl, 1998 Edition with the 2000 Addenda.In addition to the volumetric examination with limited coverage, Duke performed a surface examination (code required) on this B9.11 item. The result from the surface examination was acceptable. The system leakage test performed each refueling outage in accordance with Table IWB-2500-1; Examination Category B-P requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric, surface, and pressure test), Reactor Building Normal Sump monitoring provides additional assurance that, in the event that leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the acceptable results of the surface examinations performed during this outage, the pressure testing (VT-2) examinations required by Section XI, and the leakage monitoring, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 7 of 71 Relief Request 11 ON 002 4.0 Weld #2-PIB1-8 4.1. ASME Code Component(s) Affected Unit 2 Reactor Coolant Pump 2B1 Casing Nozzle to Safe-End Weld, Weld#2-PIB1-8, Summary Number 02.B9.11.0058 4.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section Xl, 1998 Edition through the 2000 Addenda 4.3. Applicable Code Requirement IWB-2500, Table IWB-2500-1, Examination Category B-J, Item Number B9.11 Figure IWB-2500-8 (c), 100% Volume Coverage of Examination Volume C-D-E-F 4.4. Impracticality of Compliance This item is a cast stainless steel pump casing nozzle welded to a stainless steel safe end. This weld has a diameter of 33.50 inches and a wall thickness of 2.33 inches.Scanning requirements are described in 10CFR.50.55a(b)(2)(xv) (A)(1). The aggregate coverage was calculated from the following: 0 600 shear waves obtained 0% coverage in one axial direction (S1 -nozzle)* 600 shear waves obtained 50% coverage in one axial direction (S2 -pipe)* 450 shear waves obtained 50% coverage in one circ. directions (S3 -CW)* 450 shear waves obtained 50% coverage in one circ. directions (S4 -CcW)* The aggregate coverage was calculated to be (50% + 0% + 50% +50%)/4 = 37.5%.* 600 longitudinal waves obtained 47.3% supplemental coverage beyond the weld centerline in one axial direction (S2 -pipe). This is not included in the aggregate coverage.* In addition, a best effort examination was performed in two axial directions (S1, S2) using 600 and 70° longitudinal waves to the extent possible in the upper 2/3 area of interest.The individual scan results are recorded on the form labeled "Determination of Percent Coverage for UT Examinations -Pipe. The limitation was caused by the cast stainless material and the weld taper configuration created by the attachment of the nozzle to safe end configuration. In order to scan all of the required volume for this weld, the pump would have to be replaced with Page 8 of 71 Relief Request 11 ON 002 forged stainless steel and would have to be redesigned to allow scanning from both sides of the weld, which is impractical. The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than, 90% volumetric coverage of examination volume C-D-E-F. The achieved coverage did not meet the acceptance criteria of this Code Case.4.5. Proposed Alternative and Basis for Use No alternative examinations are planned for the weld during the current inspection interval. Radiography (RT) is not a desired option because RT is limited in the ability to detect expected degradation mechanisms such as thermal fatigue cracking and stress corrosion crack initiating at the pipe inside surface. Additionally, radiography has not been qualified through performance demonstration. 4.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.4.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 02.B9.11.0058 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section XI, 1998 Edition with the 2000 Addenda.In addition to the volumetric examination with limited coverage, Duke performed a surface examination (code required) on this B9.11 item. The result from the surface examination was acceptable. The system leakage test performed each refueling outage in accordance with Table IWB-2500-1; Examination Category B-P requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric, surface, and pressure test), Reactor Building Normal Sump monitoring provides additional assurance that, in the event that leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the acceptable results of the surface examinations performed during this outage, the pressure testing (VT-2) examinations required by Section XI, and the leakage monitoring, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 9 of 71 Relief Request 11 ON 002 5.0 Weld #2-53A-1 0-3 5.1. ASME Code Component(s) Affected Unit 2 Pipe to Valve 2LP-1 Weld, Weld #2-53A-10-3, Summary Number 02.B9.11.0067 5.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section XI, 1998 Edition through the 2000 Addenda 5.3. Applicable Code Requirement IWB-2500, Table IWB-2500-1, Examination Category B-J, Item Number B9.11 Figure IWB-2500-8 (c), 100% Volume Coverage of Examination Volume C-D-E-F 5.4. Impracticality of Compliance This item is a cast stainless steel valve welded to stainless steel pipe. This weld has a diameter of 12.0 inches and a wall thickness of 1.125 inches.Scanning requirements are described in10CFR.50.55a(b)(2)(xv)(A)(1). The aggregate coverage was calculated as follows: 0 600 shear waves obtained 0% coverage in one axial direction (S1 -valve)0 600 shear waves obtained 50% coverage in one axial direction (S2 -pipe)* 450 shear waves obtained 50% coverage in one circ. direction (S3 -CW)0 450 shear waves obtained 50% coverage in one circ. direction (S4 -CCW)0 The aggregate coverage was calculated to be (0% + 50% +50% +50%)/4 = 37.5%* 600 longitudinal waves obtained 50% supplemental coverage beyond the weld centerline in one axial direction (S2 -pipe). This is not included in the aggregate coverage.In order to scan all of the required volume for this weld, the valve would have to be replaced with forged stainless steel, and be redesigned to allow scanning from both sides of the weld, which is impractical. The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. Therefore, the available coverage will not meet the acceptance criteria of this Code Case.Page 10 of 71 Relief Request 11 ON 002 5.5. Proposed Alternative and Basis for Use No alternative examinations are planned for the weld during the current inspection interval. Radiography (RT) is not a desired option because RT is limited in the ability to detect expected degradation mechanisms such as thermal fatigue cracking and stress corrosion crack initiating at the pipe inside surface. Additionally, radiography has not been qualified through performance demonstration. 5.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.5.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 02.1B9.111.0067 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section XI, 1998 Edition with the 2000 Addenda.In addition to the volumetric examination with limited coverage, Duke performed a surface examination (code required) on this B9.11 item. The result from the surface examination was acceptable. The system leakage test performed each refueling outage in accordance with Table IWB-2500-1; Examination Category B-P requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric, surface, and pressure test), Reactor Building Normal Sump monitoring provides additional assurance that, in the event that leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the acceptable results of the surface examinations performed during this outage, the pressure testing (VT-2) examinations required by Section Xl, and the leakage monitoring, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 11 of 71 Relief Request 11 ON 002 6.0 Weld #2LP-150-17 6.1. ASME Code Component(s) Affected Unit 2 Pipe to Valve 2LP-48 Weld, Weld #2-LP-150-17, Summary Number 02.C5.11.0005 6.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section Xl, 1998 Edition through the 2000 Addenda 6.3. Applicable Code Requirement IWC-2500, Table IWC-2500-1, Examination Category C-F-I, Item Number C5.1 1 Figure IWC-2500-7(a), 100% Volume Coverage of Examination Volume C-D-E-F 6.4. Impracticality of Compliance This item is a cast stainless valve welded to stainless steel pipe. This weld has a diameter of 10.0 inches and a wall thickness of 1.125 inches.Scanning requirements are described in 1OCFR.50.55a(b)(2)(xv)(A)(1). The aggregate coverage was calculated as follows:* 450 shear waves obtained 0% coverage in one axial direction (S1 -valve)0 450 shear waves obtained 50% coverage in one axial direction (S2 -pipe)* 450 shear waves obtained 50% coverage in one circ. direction (S3 -CW)* 450 shear waves obtained 50% coverage in one circ. direction (S4 -CCW)* The aggregate coverage was calculated to be (0% + 50% +50% +50%)/4 = 37.5%In order to scan all of the required volume for this weld, the valve would have to be replaced with forged stainless steel and be redesigned to allow scanning from both sides of the weld, which is impractical. The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. Therefore, the available coverage will not meet the acceptance criteria of this Code Case.Page 12 of 71 Relief Request 11 ON 002 6.5. Proposed Alternative and Basis for Use No alternative examinations are planned for the weld during the current inspection interval. Radiography (RT) is not a desired option because RT is limited in the ability to detect expected degradation mechanisms such as thermal fatigue cracking and stress corrosion crack initiating at the pipe inside surface. Additionally, radiography has not been qualified through performance demonstration. 6.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.6.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 02.C5.11.0005 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section Xl, 1998 Edition with the 2000 Addenda.In addition to the volumetric examination with limited coverage, Duke performed a surface examination (code required) on this C5.11 item. The result from the surface examination was acceptable. The system leakage test performed each inspection period in accordance with Table IWC-2500-1; Examination Category C-H requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric, surface, and pressure test), Reactor Building Normal Sump monitoring provides additional assurance that, in the event that leakage did occur through this*weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the acceptable results of the surface examinations performed during this outage, the pressure testing (VT-2) examinations required by Section XI, and the leakage monitoring, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 13 of 71 Relief Request 11 ON 002 7.0 Weld #2LP-217-8 7.1. ASME Code Component(s) Affected Unit 2 Pipe to Valve 2LP-178 Weld, Weld #2-LP-217-8, Summary Number 02.C5.11.0021 7.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section Xl, 1998 Edition through the 2000 Addenda 7.3. Applicable Code Requirement IWC-2500, Table IWC-2500-1, Examination Category C-F-i, Item Number C5.11 Figure IWC-2500-7(a), 100% Volume Coverage of Examination Volume C-D-E-F.7.4. Impracticality of Compliance This item is a stainless steel valve welded to stainless steel pipe. This weld has a diameter of 10.0 inches and a wall thickness of 1.0 inches.Scanning requirements are described in 1OCFR.50.55a(b)(2)(xv)(A)(1). The aggregate coverage was calculated as follows: 0 600 shear waves obtained 50% coverage in one axial direction (SI -pipe)* 600 shear waves obtained 0% coverage in one axial direction (S2 -valve)* 450 shear waves obtained 50% coverage in one circ. direction (S3 -CW)* 450 shear waves obtained 50% coverage in one circ. direction (S4 -CCW)* The aggregate coverage was calculated to be (50% + 0% +50% +50%)/4 = 37.5%In order to scan all of the required volume for this weld, the valve would have to be redesigned to allow scanning from both sides of the weld, which is impractical. The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage.Therefore, the available coverage will not meet the acceptance criteria of this Code Case.Page 14 of 71 Relief Request 11 ON 002 7.5. Proposed Alternative and Basis for Use No alternative examinations are planned for the weld during the current inspection interval. Radiography (RT) is not a desired option because RT is limited in the ability to detect expected degradation mechanisms such as thermal fatigue cracking and stress corrosion crack initiating at the pipe inside surface. Additionally, radiography has not been qualified through performance demonstration. 7.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.7.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 02.C5.11.0021 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section Xl, 1998 Edition with the 2000 Addenda.In addition to the volumetric examination with limited coverage, Duke performed a surface examination (code required) on this C5.11 item. The result from the surface examination was acceptable. The system leakage test performed each inspection period in accordance with Table IWC-2500-1; Examination Category C-H requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric, surface, and pressure test), Reactor Building Normal Sump monitoring provides additional assurance that, in the event that leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the acceptable results of the surface examinations performed during this outage, the pressure testing (VT-2) examinations required by Section Xl, and the leakage monitoring, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 15 of71 Relief Request 11 ON 002 8.0 Weld #2-53A-9-16 8.1. ASME Code Component(s) Affected Unit 2 Pipe to Valve 2LP-48 Weld, Weld #2-53A-9-16, Summary Number 02.C5.11.0025 8.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section XI, 1998 Edition through the 2000 Addenda 8.3. Applicable Code Requirement IWC-2500, Table IWC-2500-1, Examination Category C-F-i, Item Number C5.11 Figure IWC-2500-7(a), 100% Volume Coverage of Examination Volume C-D-E-F 8.4. Impracticality of Compliance This item is a cast stainless steel valve welded to Stainless steel pipe. This weld has a diameter of 10.0 inches and a wall thickness of 1.0 inches.Scanning requirements are described in 10CFR.50.55a (b)(2)(xv)(A)(1). The aggregate coverage was calculated as follows:* 450 shear waves obtained 50% coverage in one axial direction (S1 -pipe)* 450 shear waves obtained 0% coverage in one axial direction (S2 -valve)* 450 shear waves obtained 50% coverage in one circ. direction (S3 -CW)* 450 shear waves obtained 50% coverage in one circ. direction (S4 -CCW)* The aggregate coverage was calculated to be (50% + 0% +50% +50%)/4 = 37.5%In order to scan all of the required volume for this weld, the valve would have to be replaced with forged stainless steel, which is impractical. The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. Therefore, the available coverage will not meet the acceptance criteria of this Code Case.Page 16 of 71 Relief Request 11 ON 002 8.5. Proposed Alternative and Basis for Use No alternative examinations are planned for the weld during the current inspection interval. Radiography (RT) is not a desired option because RT is limited in the ability to detect expected degradation mechanisms such a's thermal fatigue cracking and stress corrosion crack initiating at the pipe inside surface. Additionally, radiography has not been qualified through performance demonstration. 8.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.8.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 02.C5.11.0025 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section Xl, 1998 Edition with the 2000 Addenda.In addition to the volumetric examination with limited coverage, Duke performed a surface examination (code required) on this C5.11 item. The result from the surface examination was acceptable. The system leakage test performed each inspection period in accordance with Table IWC-2500-1; Examination Category C-H requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric, surface, and pressure test), Reactor Building Normal Sump monitoring provides additional assurance that, in the event that leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the acceptable results of the surface examinations performed during this outage, the pressure testing (VT-2) examinations required by Section XI, and the leakage monitoring, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 17 of 71 Relief Request 11 ON 002 9.0 Weld #2LP-189-14 9.1. ASME Code Component(s) Affected Unit 2 Pipe to Elbow Weld, Weld #2LP-189-14, Summary Number 02.C5.11.0034 9.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section Xl, 1998 Edition through the 2000 Addenda 9.3. Applicable Code Requirement IWC-2500, Table IWC-2500-1, Examination Category C-F-i, Item Number C5.11 Figure IWC-2500-7(a), 100% Volume Coverage of Examination Volume C-D-E-F 9.4. Impracticality of Compliance This item is stainless steel seamless pipe welded to a stainless steel elbow.This weld has a diameter of 10.0 inches and a wall thickness of 1.0 inches.During the ultrasonic examination of this weld, 76% coverage of the required examination volume was obtained. Scanning requirements are described in 1OCFR.50.55a(b)(2)(xv)(A)(1). The aggregate coverage was calculated as follows: 600 shear waves obtained (61.5% + 19.25%) = 80.75 coverage in one axial direction (S1 -pipe)600 shear waves obtained (61.5% + 0.00%) = 61.5% coverage in one axial direction (S2 -elbow)* 450 shear waves obtained (61.5% + 19.25%) = 80.75% coverage in one circ. direction (S3 -CW)* 450 shear waves obtained (61.5% + 19.25%) = 80.75% coverage in one circ. direction (S4 -CCW)* The aggregate coverage was calculated to be (80.75% + 61.5% +80.75% + 80.75%)/4 = 76.0%In order to scan all of the required volume for this weld, the permanent hanger would have to be removed, which is impractical. The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. Therefore, the available coverage will not meet the acceptance criteria of this Code Case.Page 18 of 71 Relief Request 11 ON 002 9.5. Proposed Alternative and Basis for Use No alternative examinations are planned for the weld during the current inspection interval. Radiography (RT) is not a desired option because RT is limited in the ability to detect expected degradation mechanisms such as thermal fatigue cracking and stress corrosion crack initiating at the pipe inside surface. Additionally, radiography has not been qualified through performance demonstration. 9.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.9.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 02.C5.11.0034 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section Xl, 1998 Edition with the 2000 Addenda.In addition to the volumetric examination with limited coverage, Duke performed a surface examination (code required) on this C5.11 item The result from the surface examination was acceptable. The system leakage test performed each inspection period in accordance with Table IWC-2500-1; Examination Category C-H requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric, surface, and pressure test), Reactor Building Normal Sump monitoring provides additional assurance that, in the event that leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the acceptable results of the surface examinations performed during this outage, the pressure testing (VT-2) examinations required by Section Xl, and the leakage monitoring, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 19 of 71 Relief Request 11 ON 002 10.0 Weld #2LP-215-17 10.1. ASME Code Component(s) Affected Unit 2 Pipe to Flow Restrictor Weld, Weld #2LP-215-17, Summary Number 02.C5.11.0036 10.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section XI, 1998 Edition through the 2000 Addenda 10.3. Applicable Code Requirement IWC-2500, Table IWC-2500-1, Examination Category C-F-I, Item Number C5.11 Figure IWC-2500-7(a), 100% Volume Coverage of Examination Volume C-D-E-F 10.4. Impracticality of Compliance This item is a cast stainless steel flow restrictor welded to stainless steel seamless pipe. This weld has a diameter of 10.0 inches and a wall thickness of 1.0 inches.Scanning requirements are described in 10CFR.50.55a(b)(2)(xv)(A)(1). The aggregate coverage was calculated as follows:* 600 shear waves obtained 0% coverage in one axial direction (S1 -flow restrictor)

  • 600 shear waves obtained (45.5% + 1.70%) = 47.2% coverage in one axial direction (S2 -pipe)450 shear waves obtained 50% coverage in one circ. direction (S3 -CW)* 450 shear waves obtained 50% coverage in one circ. direction (S4 -CCW)* The aggregate coverage was calculated to be (0% + 47.2% +50% +50%)/4 = 36.8%In order to scan all of the required volume for this weld, the flow restrictor would have to be replaced with forged stainless steel to allow scanning from both sides of the weld, and the coupling would have to be removed, which is impractical.

The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. Therefore, the available coverage will not meet the acceptance criteria of this Code Case.Page 20 of 71 Relief Request 11 ON 002 10.5. Proposed Alternative and Basis for Use No alternative examinations are planned for the weld during the current inspection interval. Radiography (RT) is not a desired option because RT is limited in the ability to detect expected degradation mechanisms such as thermal fatigue cracking and stress corrosion crack initiating at the pipe inside surface. Additionally, radiography has not been qualified through performance demonstration. 10.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.10.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 02.C5.11.0036 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section XI, 1998 Edition with the 2000 Addenda.In addition to the volumetric examination with limited coverage, Duke performed a surface examination (code required) on this C5.11 item. The result from the surface examination was acceptable. The system leakage test performed each inspection period in accordance with Table IWC-2500-1; Examination Category C-H requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric, surface, and pressure test), Reactor Building Normal Sump monitoring provides additional assurance that, in the event that leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the acceptable results of the surface examinations performed during this outage, the pressure testing (VT-2) examinations required by Section Xl, and the leakage monitoring, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 21 of 71 Relief Request 11 ON 002 11.0 Weld #2LP-218-23 S1.1. ASME Code Component(s) Affected Unit 2 Pipe to Valve 2LP-176 Weld, Weld #2LP-218-23, Summary Number 02.C5.11.0067 11.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section XI, 1998 Edition through the 2000 Addenda 11.3. Applicable Code Requirement IWC-2500, Table IWC-2500-1, Examination Category C-F-i, Item Number C5.11 Figure IWC-2500-7(a), 100% Volume Coverage of Examination Volume C-D-E-F 11.4. Impracticality of Compliance This item is a forged stainless steel valve welded to stainless steel seamless pipe. This weld has a diameter of 10.0 inches and a wall thickness of 1.0 inches.Scanning requirements are described in 10CFR.50.55a(b)(2)(xv)(A)(1). The aggregate coverage was calculated as follows:* 600 shear waves obtained 50% coverage in one axial direction (S1 -pipe)* 600 shear waves obtained 0% coverage in one axial direction (S2 -valve)* 450 shear waves obtained 50% coverage in one circ. direction (S3 -CW)* 450 shear waves obtained 50% coverage in one circ. direction (S4 -CCW)* The aggregate coverage was calculated to be (50% + 0% +50% +50%)/4 = 37.5%In order to scan all of the required volume for this weld, the valve would have to be redesigned to allow scanning from both sides of the weld, which is impractical. The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage.Therefore, the available coverage will not meet the acceptance criteria of this Code Case.Page 22 of 71 Relief Request 11 ON 002 1 1.5. Proposed Alternative and Basis for Use No alternative examinations are planned for the weld during the current inspection interval. Radiography (RT) is not a desired option because RT is limited in the ability to detect expected degradation mechanisms such as thermal fatigue cracking and stress corrosion crack initiating at the pipe inside surface. Additionally, radiography has not been qualified through performance demonstration. 11.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.11.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 02.C5.11.0067 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section Xl, 1998 Edition with the 2000 Addenda.In addition to the volumetric examination with limited coverage, Duke performed a surface examination (code required) on this C5.11 item.. The result from the surface examination was acceptable. The system leakage test performed each inspection period in accordance with Table IWC-2500-1; Examination Category C-H requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric, surface, and pressure test), Reactor Building Normal Sump monitoring provides additional assurance that, in the event that leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the acceptable results of the surface examinations performed during this outage, the pressure testing (VT-2) examinations required by Section Xl, and the leakage monitoring, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 23 of 71 Relief Request 11 ON 002 12.0 Weld #2-51A-28-15 12.1. ASME Code Component(s) Affected Unit 2 Pipe to Flange Weld, Weld #2-51A-28-15, Summary Number 02.C5.21.0027 12.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section XI, 1998 Edition through the 2000 Addenda 12.3. Applicable Code Requirement IWC-2500, Table IWC-2500-1, Examination Category C-F-i, Item Number C5.21 Fig. IWC-2500-7(a), 100% Volume Coverage of Examination Volume C-D-E-F 12.4. Impracticality of Compliance This item is a forged stainless steel flange welded to stainless steel seamless pipe. This weld has a diameter of 4.0 inches and a wall thickness of .531 inches.Scanning requirements are described in 1OCFR.50.55a(b)(2)(xv)(A)(1). The aggregate coverage was calculated as follows:* 450 shear waves obtained 50% coverage in one axial direction (S1 -pipe)* 450 shear waves obtained 0% coverage in one axial direction (S2 -flange)0 450 shear waves obtained 50% coverage in one circ. direction (S3 -CW)0 450 shear waves obtained 50% coverage in one circ. direction (S4 -CCW)* The aggregate coverage was calculated to be (50% + 0% +50% +50%)/4 = 37.5%In order to scan all of the required volume for this weld, the flange would have to be redesigned, which is impractical. The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. Therefore, the available coverage will not meet the acceptance criteria of this Code Case.Page 24 of 71 Relief Request 11 ON 002 12.5. Proposed Alternative and Basis for Use No alternative examinations are planned for the weld during the current inspection interval. Radiography (RT) is not a desired option because RT is limited in the ability to detect expected degradation mechanisms such as thermal fatigue cracking and stress corrosion crack initiating at the pipe inside surface. Additionally, radiography has not been qualified through performance demonstration. 12.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.12.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 02.C5.21.0027 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section Xl, 1998 Edition with the 2000 Addenda.In addition to the volumetric examination with limited coverage, Duke performed a surface examination (code required) on this C5.21 item. The result from the surface examination was acceptable. The system leakage test performed each inspection period in accordance with Table IWC-2500-1; Examination Category C-H requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric, surface, and pressure test), visual observations performed during operator rounds provide additional assurance that in the event leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the acceptable results of the surface examinations performed during this outage, the pressure testing (VT-2) examinations required by Section XI, and the continuing periodic leakage inspections, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 25 of71 Relief Request 11 ON 002 13.0 Weld #2-51A-28-21 13.1. ASME Code Component(s) Affected Unit 2 Pipe to Valve 2HP-135 Weld, Weld #2-51A-28-21, Summary Number 02.C5.21.0029 13.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section Xl, 1998 Edition through the 2000 Addenda 13.3. Applicable Code Requirement IWC-2500, Table IWC-2500-1, Examination Category C-F-i, Item Number C5.21 Fig. IWC-2500-7(a), 100% Volume Coverage of Examination Volume C-D-E-F 13.4. Impracticality of Compliance This item is a forged stainless steel valve welded to stainless steel seamless pipe. This weld has a diameter of 4.0 inches and a wall thickness of .531 inches.Scanning requirements are described in 10CFR.50.55a(b)(2)(xv)(A)(1). The aggregate coverage was calculated as follows:* 600 shear waves obtained 100% coverage in one axial direction (S1 -valve)0 600 shear waves obtained 100% coverage in one axial direction (S2 -pipe)0 450 shear waves obtained 50% coverage in one circ. direction (S3 -CW)* 450 shear waves obtained 50% coverage in one circ. direction (S4 -CCW)* The aggregate coverage was calculated to be (100% + 100% + 50%+ 50%)/4 = 75.0%In order to scan all of the required volume for this weld, the valve would have to be redesigned to allow scanning from both sides of the weld, which is impractical. The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. Therefore, the available coverage will not meet the acceptance criteria of this Code Case.Page 26 of 71 Relief Request 11 ON 002 13.5. Proposed Alternative and Basis for Use No alternative examinations are planned for the weld during the current inspection interval. Radiography (RT) is not a desired option because RT is limited in the ability to detect expected degradation mechanisms such as thermal fatigue cracking and stress corrosion crack initiating at the pipe inside surface. Additionally, radiography has not been qualified through performance demonstration. 13.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.13.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 02.C5.21.0029 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section Xl, 1998 Edition with the 2000 Addenda.In addition to the volumetric examination with limited coverage, Duke performed a surface examination (code required) on this C5.21 item. The result from the surface examination was acceptable. The system leakage test performed each inspection period in accordance with Table IWC-2500-1; Examination Category C-H requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric, surface, and pressure test), visual observations performed during operator rounds provide additional assurance that in the event leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the acceptable results of the surface examinations performed during this outage, the pressure testing (VT-2) examinations required by Section XI, and the continuing periodic leakage inspections, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 27 of 71 Relief Request 11 ON 002 14.0 Weld #2HP-222-2 14.1. ASME Code Component(s) Affected Unit 2 High Pressure Injection System Elbow to Valve 2HP-26 Weld, Weld#2HP-222-2, Summary Number 02.C5.21.0031 14.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section Xl, 1998 Edition through the 2000 Addenda 14.3. Applicable Code Requirement IWC-2500, Table IWC-2500-1, Examination Category C-F-i, Item Number C5.21 Fig. IWC-2500-7(a), 100% Volume Coverage of Examination Volume C-D-E-F 14.4. Impracticality of Compliance This item is a cast stainless steel valve welded to a stainless steel elbow.This weld has a diameter of 4.0 inches and a wall thickness of .674 inches.Scanning requirements are described in 10CFR.50.55a(b)(2)(xv)(A)(1). The aggregate coverage was calculated as follows:* 600 shear waves obtained 50% coverage in one axial direction (S1 -elbow)* 600 shear waves obtained 0% coverage in one axial direction (S2 -valve)* 420 shear waves obtained 50% coverage in one circ. direction (S3 -CW)* 420 shear waves obtained 50% coverage in one circ. direction (S4 -CCW)0 The aggregate coverage was calculated to be (50% + 0% +50% +50%)/4 = 37.5%In order to scan all of the required volume for this weld, the valve would have to be replaced with forged stainless steel, which is impractical. The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. Therefore, the available coverage will not meet the acceptance criteria of this Code Case.Page 28 of 71 Relief Request 11 ON 002 14.5. Proposed Alternative and Basis for Use No alternative examinations are planned for the weld during the current inspection interval. Radiography (RT) is not a desired option because RT is limited in the ability to detect expected degradation mechanisms such as thermal fatigue cracking and stress corrosion crack initiating at the pipe inside surface. Additionally, radiography has not been qualified through performance demonstration. 14.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.14.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 02.C5.21.0031 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section XI, 1998 Edition with the 2000 Addenda.In addition to the volumetric examination with limited coverage, Duke performed a surface examination (code required) on this C5.21 item. The result from the surface examination was acceptable. The system leakage test performed each inspection period in accordance with Table IWC-2500-1; Examination Category C-H requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric, surface, and pressure test), visual observations performed during operator rounds provide additional assurance that in the event leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the acceptable results of the surface examinations performed during this outage, the pressure testing (VT-2) examinations required by Section XI, and the continuing periodic leakage inspections, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 29 of 71 Relief Request 11 ON 002 15.0 Weld #2-51A-17-93 15.1. ASME Code Component(s) Affected Unit 2 Pipe to Tee Weld, Weld #2-51A-17-93, Summary Number 02.C5.21.0055 15.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section Xl, 1998 Edition through the 2000 Addenda 15.3. Applicable Code Requirement IWC-2500, Table IWC-2500-1, Examination Category C-F-i, Item Number C5.21 Fig. IWC-2500-7(a), 100% Volume Coverage of Examination Volume C-D-E-F 15.4. Impracticality of Compliance This item is a forged stainless steel tee welded to stainless steel seamless pipe. This weld has a diameter of 2.5 inches and a wall thickness of .375 inches.Scanning requirements are described in 10CFR.50.55a(b)(2)(xv)(A)(1). The aggregate coverage was calculated as follows: 600 shear waves obtained 78% coverage in one axial direction (S1 -pipe)* 600 shear waves obtained 56% coverage in one axial direction (S2 -tee)* 450 shear waves obtained 100% coverage in one circ. direction (S3 -CW)450 shear waves obtained 100% coverage in one circ. direction (S4 -CCW)The aggregate coverage was calculated to be (78% + 56% + 100% +100%)/4 = 83.5%In order to scan all of the required volume for this weld, the tee would have to be redesigned to allow scanning from both sides of the weld, which is impractical. The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. Therefore, the available coverage will not meet the acceptance criteria of this Code Case.Page 30 of 71 Relief Request 11 ON 002 15.5. Proposed Alternative and Basis for Use No alternative examinations are planned for the weld during the current inspection interval. Radiography (RT) is not a desired option because RT is limited in the ability to detect expected degradation mechanisms such as thermal fatigue cracking and stress corrosion crack initiating at the pipe inside surface. Additionally, radiography has not been qualified through performance demonstration. 15.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.15.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 02.C5.21.0055 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section XI, 1998 Edition with the 2000 Addenda.In addition to the volumetric examination with limited coverage, Duke performed a surface examination (code required) on this C5.21 item. The result from the surface examination was acceptable. The system leakage test performed each inspection period in accordance with Table IWC-2500-1; Examination Category C-H requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric, surface, and pressure test), visual observations performed during operator rounds provide additional assurance that in the event leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the acceptable results of the surface examinations performed during this outage, the pressure testing (VT-2) examinations required by Section Xl, and the continuing periodic leakage inspections, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 31 of 71 Relief Request 11 ON 002 16.0 Weld #2HP-221-22 16.1. ASME Code Component(s) Affected Unit 2 Elbow to Valve 2HP-410 Weld, Weld #2HP-221-22, Summary Number 02.C5.21.0256 16.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section Xl, 1998 Edition through the 2000 Addenda 16.3. Applicable Code Requirement IWC-2500, Table IWC-2500-1, Examination Category C-F-I, Item Number C5.21 Fig. IWC-2500-7(a), 100% Volume Coverage of Examination Volume C-D-E-F 16.4. Impracticality of Compliance This item is a cast stainless steel valve welded to stainless steel seamless pipe. This weld has a diameter of 4.0 inches and a wall thickness of .531 inches.Scanning requirements are described in 10CFR.50.55a(b)(2)(xv)(A)(1). The aggregate coverage was calculated as follows:* 600 shear waves obtained 50% coverage in one axial direction (51 -elbow)0 600 shear waves obtained 0% coverage in one axial direction (S2 -valve)* 450 shear waves obtained 50% coverage in one circ. direction (S3 -CW)* 450 shear waves obtained 50% coverage in one circ. direction (S4 -CCW)* The aggregate coverage was calculated to be (50% + 0% +50% +50%)/4 = 37.5%In order to scan all of the required volume for this weld, the valve would have to be replaced with forged stainless steel, which is impractical. The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. Therefore, the available coverage will not meet the acceptance criteria of this Code Case.Page 32 of 71 Relief Request 11 ON 002 16.5. Proposed Alternative and Basis for Use No alternative examinations are planned for the weld during the current inspection interval. Radiography (RT) is not a desired option because RT is limited in the ability to detect expected degradation mechanisms such as thermal fatigue cracking and stress corrosion crack initiating at the pipe inside surface. Additionally, radiography has not been qualified through performance demonstration. 16.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.16.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 02.C5.21.0256 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section Xl, 1998 Edition with the 2000 Addenda.In addition to the volumetric examination with limited coverage, Duke performed a surface examination (code required) on this C5.21 item. The result from the surface examination was acceptable. The system leakage test performed each inspection period in accordance with Table IWC-2500-1; Examination Category C-H requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric, surface, and pressure test), visual observations performed during operator rounds provide additional assurance that in the event leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the acceptable results of the surface examinations performed during this outage, the pressure testing (VT-2) examinations required by Section Xl, and the continuing periodic leakage inspections, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 33 of 71 Relief Request 11 ON 002 17.0 Weld #3-PZR-WP26-4 17.1. ASME Code Component(s) Affected Unit 3 Pressurizer Upper Shell to Sampling Nozzle Weld #3-PZR-WP26-4, Summary Number 03.B3.110.0006 17.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section XI, 1998 Edition through the 2000 Addenda 17.3. Applicable Code Requirement IWB-2500, Table IWB-2500-1, Examination Category B-D, Item Number B3.110 Fig. IWB-2500-7 (a), 100% Volume Coverage of Examination Volume A-B-C-D-E-F-G-H-I 17.4. Impracticality of Compliance

  • Surface 1: Upper Shell -Carbon steel* Surface 2: Sampling nozzle -Carbon steel* Diameter:

5.750 in.* Thickness: 6.187 in.The ultrasonic examination of this weld obtained 34.7% coverage of the required examination volume. Because of the weld configuration, the requirements of ASME Section V, Article 4, T-441.1.2(a), T-441.1.3, T-441.1.4, T-441.1.5 and T-441.1.6 could not be met. The aggregate coverage was calculated from the following base and weld metal scan results: Weld coverage using 350, 450& 600 shear waves for axial scans (S1, S2), and 350 & 450 shear waves for circ. scans (CW, CCW) obtained 15.4% coverage.Base material coverage using 350, 450& 600 shear wave for axial scans (Si) and 35°& 450 shear waves for circ. scans (CW, CCW)obtained 54.8% coverage.* 00 scan coverage obtained 33.9% coverage.* The aggregate coverage was calculated to be (15.4% + 54.8% +33.9%)/3 = 34.7%.The limitation was caused by the weld taper configuration created by the attachment of the sampling nozzle to the upper shell not allowing scanning from Surface 2. In order to scan all of the required volume for this weld, the upper shell to sampling nozzle attachment weld would have to be redesigned to allow scanning from both sides of the weld, which is impractical. Page 34 of 71 Relief Request 11 ON 002 The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. The achieved coverage did not meet the acceptance criteria of this Code Case.17.5. Proposed Alternative and Basis for Use No substitution alternative for this weld is available which would provide better coverage.17.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.17.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 03.B3.110.0006 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section Xl, 1998 Edition with the 2000 Addenda.The system leakage test performed each refueling outage in accordance with Table IWB-2500-1; Examination Category B-P requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric and pressure test), Reactor Building Normal Sump rate monitoring provides additional assurance that, in the event that leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component tothe maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the pressure testing (VT-2) examinations required by Section Xl, and the leakage monitoring, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 35 of 71 Relief Request 11 ON 002 18.0 Weld #3-PZR-WP26-5 18.1. ASME Code Component(s) Affected Unit 3 Pressurizer Upper Shell to Sampling Nozzle Weld #3-PZR-WP26-5, Summary Number 03.B3.110.0007 18.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section XI, 1998 Edition through the 2000 Addenda 18.3. Applicable Code Requirement IWB-2500, Table IWB-2500-1, Examination Category B-D, Item Number B3.110 Fig. IWB-2500-7 (a), 100% Volume Coverage of Examination Volume A-B-C-D-E-F-G-H-I 18.4. Impracticality of Compliance

  • Surface 1: Upper Shell -Carbon steel* Surface 2: Sampling nozzle -Carbon steel* Diameter:

5.750 in.* Thickness: 6.187 in.The ultrasonic examination of this weld obtained 34.7% coverage of the required examination volume. Because of the weld configuration, the requirements of ASME Section V, Article 4, T-441.1.2(a), T-441.1.3, T-441.1.4, T-441.1.5 and T-441.1.6 could not be met. The aggregate coverage was calculated from the following base and weld metal scan results: Weld coverage using 350, 45°& 600 shear waves for axial scans (S1, S2), and 350 & 450 shear waves for circ. scans (CW, CCW) obtained 15.4% coverage.Base material coverage using 350, 45%& 600 shear wave for axial scans (51) and 35°& 450 shear waves for circ. scans (CW, CCW)obtained 54.8% coverage.* 00 scan coverage obtained 33.9% coverage.* The aggregate coverage was calculated to be (15.4% + 54.8% +33.9%)/3 = 34.7%.The limitation was caused by the weld taper configuration created by the attachment of the sampling nozzle to the upper shell not allowing scanning from Surface 2. In order to scan all of the required volume for this weld, the upper shell to sampling nozzle attachment weld would have to be redesigned to allow scanning from both sides of the weld, which is impractical. Page 36 of 71 Relief Request 11 ON 002 The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. The achieved coverage did not meet the acceptance criteria of this Code Case.18.5. Proposed Alternative and Basis for Use No substitution alternative for this weld is available which would provide better coverage.18.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.18.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 03.B3.110.0007 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section Xl, 1998 Edition with the 2000 Addenda.The system leakage test performed each refueling outage in accordance with Table IWB-2500-1; Examination Category B-P requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric and pressure test), Reactor Building Normal Sump rate monitoring provides additional assurance that, in the event that leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the pressure testing (VT-2) examinations required by Section XI, and the leakage monitoring, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 37 of 71 Relief Request 11 ON 002 19.0 Weld #3-PZR-WP26-6 19.1. ASME Code Component(s) Affected Unit 3 Pressurizer Upper Shell to Sampling Nozzle Weld, Weld #3-PZR-WP26-6, Summary Number 03.B3.110.0008. 19.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section Xl, 1998 Edition through the 2000 Addenda.19.3. Applicable Code Requirement IWB-2500, Table IWB-2500-1, Examination Category B-D, Item Number B3.110 Fig. IWB-2500-7 (a), 100% Volume Coverage of Examination Volume A-B-C-D-E-F-G-H-I 19.4. Impracticality of Compliance

  • Surface 1: Upper Shell -Carbon steel* Surface 2: Sampling nozzle -Carbon steel* Diameter:

5.750 in.* Thickness: 6.187 in.The ultrasonic examination of this weld obtained 34.7% coverage of the required examination volume. Because of the weld configuration, the requirements of ASME Section V, Article 4, T-441.1.2(a), T-441.1.3, T-441.1.4, T-441.1.5 and T-441.1.6 could not be met. The aggregate coverage was calculated from the following base and weld metal scan results: Weld coverage using 350, 450& 600 shear waves for axial scans (S1, S2), and 350 & 450 shear waves for circ. scans (CW, CCW) obtained 15.4% coverage.Base material coverage using 350, 450& 600 shear wave for axial scans (51) and 350& 450 shear waves for circ. scans (CW, CCW)obtained 54.8% coverage.* 00 scan coverage obtained 33.9% coverage.° The aggregate coverage was calculated to be (15.4% + 54.8% +33.9%)/3 = 34.7%.The limitation was caused by the weld taper configuration created by the attachment of the sampling nozzle to the upper shell not allowing scanning from Surface 2. In order to scan all of the required volume for this weld, the upper shell to sampling nozzle attachment weld would have to be redesigned to allow scanning from both sides of the weld, which is impractical. Page 38 of 71 Relief Request 11 ON 002 The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. The achieved coverage did not meet the acceptance criteria of this Code Case.19.5. Proposed Alternative and Basis for Use No substitution alternative for this weld is available which would provide better coverage.19.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.19.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 03.B3.110.0008 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section Xl, 1998 Edition with the 2000 Addenda.The system leakage test performed each refueling outage in accordance with Table IWB-2500-1; Examination Category B-P requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric and pressure test), Reactor Building Normal Sump rate monitoring provides additional assurance that, in the event that leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the pressure testing (VT-2) examinations required by Section XI, and the leakage monitoring, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 39 of 71 Relief Request 11 ON 002 20.0 Weld #3-LDCA-IN-2V 20.1. ASME Code Component(s) Affected Unit 3 Letdown Cooler 3A Nozzle to Channel Body Weld #3-LDCA-IN-2V, Summary Number 03.B3.150.0001. 20.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section Xl, 1998 Edition through the 2000 Addenda.20.3. Applicable Code Requirement Table IWB-2500-1, Examination Category B-D, Item Number B3.150 Figure IWB-2500-7(c), 100% Volume Coverage of Examination Volume A-B-C-D-E-F-G-H.20.4. Impracticality of Compliance

  • Surface 1: Channel Body -Stainless Steel* Surface 2: Inlet Nozzle -Stainless Steel* Diameter:

3.0 in.* Thickness: 0.875 in.The ultrasonic examination of the Inlet Nozzle to Channel Body weld obtained 53.1% coverage of the required examination volume. ASME Section XI, Appendix III, 111-4420 requires coverage of the examination volume in two beam path directions and Appendix II1, 111-4430 requires scanning on the weld crown in two directions. Because of the weld configuration, these requirements could not be met. The aggregate coverage was calculated from the following base and weld metal scan results: Base material coverage: 450 shear waves and 450, 600, and 700 longitudinal waves for the axial scans (S1)and 45 0 shear waves for the circ scans (CW, CCW) obtained an aggregate coverage of 56.4%.Weld metal coverage: 450 shear waves and 45°, 600, and 70°longitudinal waves for the axial scans(S1, 32) and 45 0 shear waves for the circ scans (CW, CCW) obtained an aggregate coverage of 49.8%.The aggregate coverage was calculated to be (56.4% + 49.8% =106.2%)/2 = 53.1%.The limitation was caused by the design of the nozzle weld taper configuration created by the attachment of the channel body connection to the nozzle not allowing for scanning from Surface 2. In order to scan all of the required volume for this weld, the inlet nozzle would have to be redesigned to allow scanning from both sides of the weld, which is impractical. Page 40 of 71 Relief Request 11 ON 002 The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. The achieved coverage did not meet the acceptance criteria of this Code Case.20.5. Proposed Alternative and Basis for Use No substitution alternative for this weld is available which would provide better coverage.20.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.20.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 03.B3.150.0001 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section Xl, 1998 Edition with the 2000 Addenda.The system leakage test performed each refueling outage in accordance with Table IWB-2500-1; Examination Category B-P requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric and pressure test), Reactor Building Normal Sump rate monitoring provides additional assurance that, in the event that leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the pressure testing (VT-2) examinations required by Section XI, and the leakage monitoring, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 41 of 71 Relief Request 11 ON 002 21.0 Weld #3-LDCA-OUT-5V 21.1. ASME Code Component(s) Affected Unit 3 Letdown Cooler 3A Nozzle to Channel Body Weld #3-LDCA-OUT-5V, Summary Number 03.B3.150.0002. 21.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section XI, 1998 Edition through the 2000 Addenda.21.3. Applicable Code Requirement Table IWB-2500-1, Examination Category B-D, Item Number B3.150 Figure IWB-2500-7(c), 100% Volume Coverage of Examination Volume A-B-C-D-E-F-G-H.21.4. Impracticality of Compliance

  • Surface 1: Channel Body -Stainless Steel* Surface 2: Outlet Nozzle -Stainless Steel* Diameter:

3.0 in.* Thickness: 0.875 in.The ultrasonic examination of the Outlet Nozzle to Channel Body weld obtained 53.1% coverage of the required examination volume. ASME Section Xl, Appendix III, 111-4420 requires coverage of the examination volume in two beam path directions and Appendix III, 111-4430 requires scanning on the weld crown in two directions. Because of the weld configuration, these requirements could not be met. The aggregate coverage was calculated from the following base and weld metal scan results: Base material coverage: 450 shear waves and 45°, 60°, and 70*longitudinal waves for the axial scans (S1)and 45 0 shear waves for the circ scans (CW, CCW) obtained an aggregate coverage of 56.4%.Weld metal coverage: 450 shear waves and 450, 600, and 70'longitudinal waves for the axial scans(S1, S2) and 45 0 shear waves for the circ scans (CW, CCW) obtained an aggregate coverage of 49.8%.The aggregate coverage was calculated to be (56.4% + 49.8% =106.2%)/2 = 53.1%.The limitation was caused by the design of the nozzle weld taper configuration created by the attachment of the channel body connection to the nozzle not allowing for scanning from Surface 2. In order to scan all of the required volume for this weld, the inlet nozzle would have to be redesigned to allow scanning from both sides of the weld, which is impractical. Page 42 of 71 Relief Request 11 ON 002 The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. The achieved coverage did not meet the acceptance criteria of this Code Case.21.5. Proposed Alternative and Basis for Use No substitution alternative for this weld is available which would provide better coverage.21.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.21.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 03.B3.150.0002 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section Xl, 1998 Edition with the 2000 Addenda.The system leakage test performed each refueling outage in accordance with Table IWB-2500-1; Examination Category B-P requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric and pressure test), Reactor Building Normal Sump rate monitoring provides additional assurance that, in the event that leakage did occur through this weld, it would be, detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the pressure testing (VT-2) examinations required by Section XI, and the leakage monitoring, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 43 of 71 Relief Request 11 ON 002 22.0 Weld #3-PDA1-1 22.1. ASME Code Component(s) Affected Unit 3 Reactor Coolant Pump 3A1 Casing Outlet Nozzle to Safe-End Piping Weld# 3-PDA1-1, Summary Number 03.B9.11.0068. 22.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section X1, 1998 Edition through the 2000 Addenda.22.3. Applicable Code Requirement IWB-2500, Table IWB-2500-1, Examination Category B-J, Item Number B9.1 1 Figure IWB-2500-8 (c), 100% Volume Coverage of Examination Volume C-D-E-F 22.4. Impracticality of Compliance Component configuration:

  • Surface 1: Stainless steel safe end* Surface 2: Cast stainless steel pump casing* NPS: 33.50 in.* Thickness:

2.330 in.Scanning requirements are described in 1OCFR.50.55a (b)(2)(xv)(A)(1). The aggregate coverage was calculated from the following:

  • 600 shear waves obtained 50% coverage in one axial direction (S1 -safe end)* 600 shear waves obtained 0.0% coverage in one axial direction (S2 -pump casing)* 450 shear waves obtained 50% coverage in one circ. direction (CW).* 450 shear waves obtained 50% coverage in one circ. direction (CCW).* The aggregate coverage was calculated to be (50% + 0% + 50% +50%)/4 = 37.5%.* In addition, a best effort examination was performed using 600 and 700 longitudinal waves to the extent possible in the upper 2/3 area of interest.The limitation was caused by the pump casing material.

In order to scan all of the required volume for this weld, the pump casing would have to be redesigned, which is impractical. Page 44 of 71 Relief Request 11 ON 002 The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. Therefore, the available coverage will not meet the acceptance criteria of this Code Case.22.5. Proposed Alternative and Basis for Use This weld was examined using procedures, equipment, and personnel qualified in accordance with ASME Section Xl, Appendix VIII. No alternative examinations are planned for the weld during the current inspection interval.Radiography (RT) is not a desired option because RT is limited in the ability to detect service induced flaws. Additionally, radiography has not been qualified through performance demonstration. 22.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.22.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 03.B9.11.0068 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section Xl, 1998 Edition with the 2000 Addenda.In addition to the volumetric examination with limited coverage, Duke performed a surface examination (code required) on this B9.11 item. The result from the surface examination was acceptable. The system leakage test performed each refueling outage in accordance with Table IWB-2500-1; Examination Category B-P requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric, surface, and pressure test), Reactor Building Normal Sump monitoring provides additional assurance that, in the event that leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the acceptable results of the surface examinations performed during this outage, the pressure testing (VT-2) examinations required by Section XI, and the leakage monitoring, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 45 of 71 Relief Request 11 ON 002 23.0 Weld #3-PDB2-1 23.1. ASME Code Component(s) Affected Unit 3 Reactor Coolant Pump 3B2 Casing Outlet Nozzle to Safe-End Piping Weld# 3-PDB2-1, Summary Number 03.B9.11.0074. 23.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section Xl, 1998 Edition through the 2000 Addenda.23.3. Applicable Code Requirement IWB-2500, Table IWB-2500-1, Examination Category B-J, Item Number B9.11 Figure IWB-2500-8 (c), 100% Volume Coverage of Examination Volume C-D-E-F 23.4. Impracticality of Compliance Component configuration:

  • Surface 1: Stainless steel safe end* Surface 2: Cast stainless steel pump casing* NPS: 33.50 in.* Thickness:

2.330 in.Scanning requirements are described in 10CFR.50.55a (b)(2)(xv)(A)(1). The aggregate coverage was calculated from the following: 600 shear waves obtained 50% coverage in one axial direction (S1 -safe end)600 shear waves obtained 0.0% coverage in one axial direction (S2 -pump casing)* 450 shear waves obtained 50% coverage in one circ. direction (CW).* 450 shear waves obtained 50% coverage in one circ. direction (CCW).* The aggregate coverage was calculated to be (50% + 0% + 50% +50%)/4 = 37.5%.In addition, a best effort examination was performed using 600 and 700 longitudinal waves to the extent possible in the upper 2/3 area of interest.The limitation was caused by the pump casing material. In order to scan all of the required volume for this weld, the pump casing would have to be redesigned, which is impractical. Page 46 of 71 Relief Request 11 ON 002 The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. Therefore, the available coverage will not meet the acceptance criteria of this Code Case.23.5. Proposed Alternative and Basis for Use This weld was examined using procedures, equipment, and personnel qualified in accordance with ASME Section XI, Appendix VIII. No alternative examinations are planned for the weld during the current inspection interval.Radiography (RT) is not a desired option because RT is limited in the ability to detect service induced flaws. Additionally, radiography has not been qualified through performance demonstration. 23.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.23.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 03.B9.11.0074 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section XI, 1998 Edition with the 2000 Addenda.In addition to the volumetric examination with limited coverage, Duke performed a surface examination (code required) on this B9.11 item. The result from the surface examination was acceptable. The system leakage test performed each refueling outage in accordance with Table IWB-2500-1; Examination Category B-P requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric, surface, and pressure test), Reactor Building Normal Sump monitoring provides additional assurance that, in the event that leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the acceptable results of the surface examinations performed during this outage, the pressure testing (VT-2) examinations required by Section Xl, and the leakage monitoring, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 47 of 71 Relief Request 11 ON 002 24.0 Weld #3-51A-52-44 24.1. ASME Code Component(s) Affected Unit 3 Pipe to Valve 3HP-105 Weld # 3-51A-52-44, Summary Number 03.C5.21.0024. 24.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section XI, 1998 Edition through the 2000 Addenda.24.3. Applicable Code Requirement IWC-2500, Table IWC-2500-1, Examination Category C-F-i, Item Number C5.21 Figure IWC-2500-7(a), 100% Volume Coverage of Examination Volume C-D-E-F 24.4. Impracticality of Compliance Component configuration:

  • Surface 1: Forged stainless steel valve* Surface 2: Stainless steel pipe* NPS: 3.0 in.* Thickness:

0.438 in.Scanning requirements are described in 10CFR.50.55a (b)(2)(xv)(A)(1). The aggregate coverage was calculated from the following: 600 shear waves obtained 100% coverage in one axial direction (S1 -valve)600 shear waves obtained 100% coverage in one axial direction (S2 -pipe)* 450 shear waves obtained 50% coverage in one circ. direction (CW).* 450 shear waves obtained 50% coverage in one circ. direction (CCW).* The aggregate coverage was calculated to be (100% + 100% + 50%+ 50%)/4 = 75.0%.The limitation was caused by the valve configuration. In order to scan all of the required volume for this weld, the valve would have to be redesigned, which is impractical. The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. Therefore, the available coverage will not meet the acceptance criteria of this Code Case.Page 48 of 71 Relief Request 11 ON 002 24.5. Proposed Alternative and Basis for Use This weld was examined using procedures, equipment, and personnel qualified in accordance with ASME Section XI, Appendix VIII. No alternative examinations are planned for the weld during the current inspection interval.Radiography (RT) is not a desired option because RT is limited in the ability to detect service induced flaws. Additionally, radiography has not been qualified through performance demonstration. 24.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.24.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 03.C5.21.0024 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section Xl, 1998 Edition with the 2000 Addenda.In addition to the volumetric examination with limited coverage, Duke performed a surface examination (code required) on this C5.21 item. The result from the surface examination was acceptable. The system leakage test performed each inspection period in accordance with Table IWC-2500-1; Examination Category C-H requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric, surface, and pressure test), visual observations performed during operator rounds provide additional assurance that in the event leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the acceptable results of the surface examinations performed during this outage, the pressure testing (VT-2) examinations required by Section XI, and the continuing periodic leakage inspections, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 49 of 71 Relief Request 11 ON 002 25.0 Weld #N32389-3 WJ32 25.1. ASME Code Component(s) Affected Unit 3 Letdown Cooler Inlet Channel Body to Chemical Connector Weld #N32389-3 WJ32, Summary Number PSI.25.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section Xl, 1998 Edition through the 2000 Addenda.25.3. Applicable Code Requirement Table IWB-2500-1, Examination Category B-B, Item Number B2.51, Figure IWB-2500-1, 100% Volume Coverage of Examination Volume A-B-C-D.25.4. Impracticality of Compliance

  • Surface 1: Inlet Channel Body -Stainless Steel* Surface 2: Chemical Connector

-Stainless Steel* Diameter: 8.625 in.* Thickness: 0.875 in.The ultrasonic examination of the Inlet Channel Body to Chemical Connector weld obtained 87.7% coverage of the required examination volume. ASME Section XI, Appendix III, 111-4420 requires coverage of the examination volume in two beam path directions and Appendix III, 111-4430 requires scanning on the weld crown in two directions. Because of the weld configuration, these requirements could not be met. The aggregate coverage was calculated from the following base and weld metal scan results: Axial scan coverage: 450 shear waves and 450, 600, and 700 longitudinal waves in the S1 and S2 direction obtained an aggregate coverage of 97.2%.* Circ scan coverage: 450 shear waves obtained an aggregate coverage of 78.1%.* The total aggregate coverage was calculated to be (97.2% + 78.1% =175.3%)/2 = 87.7%.The component limitation was caused by the taper configuration of the chemical connector and the proximity of a nozzle within the scan area from the channel body. In order to scan all of the required volume for this component, the chemical connector and location of the adjacent nozzle would have to be redesigned to allow complete scanning from both sides of the weld, which is impractical. Page 50 of 71 Relief Request 11 ON 002 The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. The achieved coverage did not meet the acceptance criteria of this Code Case.25.5. Proposed Alternative and Basis for Use No substitution alternative for this weld is available which would provide better coverage.25.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.25.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number PSI was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section Xl, 1998 Edition with the 2000 Addenda.The system leakage test performed each refueling outage in accordance with Table IWB-2500-1; Examination Category B-P requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric and pressure test), Reactor Building Normal Sump rate monitoring provides additional assurance that, in the event that leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the pressure testing (VT-2) examinations required by Section Xl, and the leakage monitoring, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 51 of 71 Relief Request 11 ON 002 26.0 Weld #N32389-3 WJ33 26.1. ASME Code Component(s) Affected Unit 3 Letdown Cooler Inlet Nozzle to Channel Body Weld # N32389-3 WJ33, Summary Number PSI.26.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section Xl, 1998 Edition through the 2000 Addenda.26.3. Applicable Code Requirement Table IWB-2500-1, Examination Category B-D, Item Number B3.150 Figure IWB-2500-7(c), 100% Volume Coverage of Examination Volume A-B-C-D-E-F-G-H.26.4. Impracticality of Compliance

  • Surface 1: Channel Body -Stainless Steel* Surface 2: Inlet Nozzle -Stainless Steel* Diameter:

3.0 in.* Thickness: 0.875 in.The ultrasonic examination of the Inlet Nozzle to Channel Body weld obtained 60.6% coverage of the required examination volume. ASME Section Xl, Appendix III, 111-4420 requires coverage of the examination volume in two beam path directions and Appendix III, 111-4430 requires scanning on the weld crown in two directions. Because of the weld configuration, these requirements could not be met. The aggregate coverage was calculated from the following base and weld metal scan results: Axial scan coverage: 450 shear waves and 450, 600, and 700 longitudinal waves in the S1 direction obtained an aggregate coverage of 52.6%.Circ scan coverage: 450 shear waves obtained an aggregate coverage of 68.6%.The aggregate coverage was calculated to be (68.6% + 52.6% =121.2%)/2 = 60.6%.The limitation was caused by the design of the nozzle weld taper configuration not allowing for scanning from Surface 2. In order to scan all of the required volume for this weld, the inlet nozzle would have to be redesigned to allow scanning from both sides of the weld, which is impractical. Page 52 of 71 Relief Request 11 ON 002 The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. The achieved coverage did not meet the acceptance criteria of this Code Case.26.5. Proposed Alternative and Basis for Use No substitution alternative for this weld is available which would provide better coverage.26.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.26.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number PSI was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section Xl, 1998 Edition with the 2000 Addenda.The system leakage test performed each refueling outage in accordance with Table IWB-2500-1; Examination Category B-P requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric and pressure test), Reactor Building Normal Sump rate monitoring provides additional assurance that, in the event that leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the pressure testing (VT-2) examinations required by Section Xl, and the leakage monitoring, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 53 of 71 Relief Request 11 ON 002 27.0 Weld #N32389-3 WJ35 27.1. ASME Code Component(s) Affected Unit 3 Letdown Cooler Outlet Channel Body to Chemical Connector Weld #N32389-3 WJ35, Summary Number PSI.27.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section Xl, 1998 Edition through the 2000 Addenda.27.3. Applicable Code Requirement Table IWB-2500-1, Examination Category B-B, Item Number B2.51 Figure IWB-2500-1, 100% Volume Coverage of Examination Volume A-B-C-D.27.4. Impracticality of Compliance

  • Surface 1: Channel Body -Stainless Steel* Surface 2: Chemical Connector

-Stainless Steel* Diameter: 8.620 in.* Thickness: 0.875 in.The ultrasonic examination of the Outlet Channel Body to Chemical Connector weld obtained 87.7% coverage of the required examination volume. ASME Section Xl, Appendix III, 111-4420 requires coverage of the examination volume in two beam path directions and Appendix III, 111-4430 requires scanning on the weld crown in two directions. Because of the weld configuration, these requirements could not be met. The aggregate coverage was calculated from the following base and weld metal scan results: Axial scan coverage: 450 shear waves and 450, 60', and 70'longitudinal waves in the S1 and S2 direction obtained an aggregate coverage of 97.2%.Circ scan coverage: 450 shear waves obtained an aggregate coverage of 78.1%.The total aggregate coverage was calculated to be (97.2% + 78.1% =175.3%)/2 = 87.7%.The component limitation was caused by the taper configuration of the chemical connector and the proximity of a nozzle within the scan area from the channel body. In order to scan all of the required volume for this component, the chemical connector and location of the adjacent nozzle would have to be redesigned to allow complete scanning from both sides of the weld, which is impractical. Page 54 of 71 Relief Request 11 ON 002 The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. The achieved coverage did not meet the acceptance criteria of this Code Case.27.5. Proposed Alternative and Basis for Use No substitution alternative for this weld is available which would provide better coverage.27.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.27.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number PSI was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section Xl, 1998 Edition with the 2000 Addenda.The system leakage test performed each refueling outage in accordance with Table IWB-2500-1; Examination Category B-P requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric and pressure test), Reactor Building Normal Sump rate monitoring provides additional assurance that, in the event that leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the pressure testing (VT-2) examinations required by Section Xl, and the leakage monitoring, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 55 of 71 Relief Request 11 ON 002 28.0 Weld #N32389-3 WJ36 28.1. ASME Code Component(s) Affected Unit 3 Letdown Cooler Outlet Nozzle to Channel Body Weld # N32389-3 WJ36, Summary Number PSI.28.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section Xl, 1998 Edition through the 2000 Addenda.28.3. Applicable Code Requirement Table IWB-2500-1, Examination Category B-D, Item Number B3.150 Figure IWB-2500-7(a), 100% Volume Coverage of Examination Volume A-B-C-D-E-F-G-H-I.28.4. Impracticality of Compliance

  • Surface 1: Channel Body -Stainless Steel* Surface 2: Outlet Nozzle -Stainless Steel* Diameter:

3.0 in.* Thickness: 0.875 in.The ultrasonic examination of the Inlet Nozzle to Channel Body weld obtained 60.6% coverage of the required examination volume. ASME Section Xl, Appendix III, 111-4420 requires coverage of the examination volume in two beam path directions and Appendix III, 111-4430 requires scanning on the weld crown in two directions. Because of the weld configuration, these requirements could not be met. The aggregate coverage was calculated from the following base and weld metal scan results: Axial scan coverage: 450 shear waves and 450, 600, and 700 longitudinal waves in the S1 direction obtained an aggregate coverage of 52.6%.Circ scan coverage: 45' shear waves obtained an aggregate coverage of 68.6%.The aggregate coverage was calculated to be (68.6% + 52.6% =121.2%)/2 = 60.6%.The limitation was caused by the design of the nozzle weld taper configuration not allowing for scanning from Surface 2. In order to scan all of the required volume for this weld, the outlet nozzle would have to be redesigned to allow scanning from both sides of the weld, which is impractical. Page 56 of 7l Relief Request 11 ON 002 The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. The achieved coverage did not meet the acceptance criteria of this Code Case.28.5. Proposed Alternative and Basis for Use No substitution alternative for this weld is available which would provide better coverage.28.6. Duration of Proposed Alternative This request is for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.28.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number PSI was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section Xl, 1998 Edition with the 2000 Addenda.The system leakage test performed each refueling outage in accordance with Table IWB-2500-1; Examination Category B-P requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric and pressure test), Reactor Building Normal Sump rate monitoring provides additional assurance that, in the event that leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the pressure testing (VT-2) examinations required by Section XI, and the leakage monitoring, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 57 of 71 Relief Request 11 ON 002 29.0 Weld #3-PIA2-8 29.1. ASME Code Component(s) Affected Unit 3 Reactor Coolant Pump 3A2 Casing Nozzle to Safe-End Weld #3-PIA2-8, Summary Number 03.B9.11.0056 29.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section Xl, 1998 Edition through the 2000 Addenda 29.3. Applicable Code Requirement IWB-2500, Table IWB-2500-1, Examination Category B-J, Item Number B9.11 Figure IWB-2500-8 (c), 100% Volume Coverage of Examination Volume C-D-E-F 29.4. Impracticality of Compliance Component configuration:

  • Surface 1: Cast Stainless Steel Pump Casing* Surface 2: Stainless Steel Safe-end* NPS: 33.50 in.* Thickness:

2.330 in.Scanning requirements are described in IOCFR.50.55a (b)(2)(xv)(A)(1). The aggregate coverage was calculated from the following: 60° shear waves obtained 0% coverage in one axial direction (S1 -pump casing)600 shear waves obtained 50% coverage in one axial direction (S2 -safe-end)* 450 shear waves obtained 50% coverage in one circ. direction (CW).* 450 shear waves obtained 50% coverage in one circ. direction (CCW).* The aggregate coverage was calculated to be (0% + 50% + 50% +50%)/4 = 37.5%.In addition, a best effort examination was performed using 60' and 70' longitudinal waves to the extent possible in the upper 2/3 area of interest.The component limitation was caused by the cast stainless pump casing material. In order to scan all of the required volume for this weld, the component would have to be redesigned, which is impractical. Page 58 of 71 Relief Request 11 ON 002 The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. Therefore, the available coverage will not meet the acceptance criteria of this Code Case.29.5. Proposed Alternative and Basis for Use This weld was examined using procedures, equipment, and personnel qualified in accordance with ASME Section XI, Appendix VIII. No alternative examinations are planned for the weld during the current inspection interval.Radiography (RT) is not a desired option because RT is limited in the ability to detect service induced flaws. Additionally, radiography has not been qualified through performance demonstration. 29.6. Duration of Proposed Alternative This request is proposed for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.29.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 03.1B9.11.0056 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section Xl, 1998 Edition with the 2000 Addenda.The system leakage test performed each refueling outage in accordance with Table IWB-2500-1; Examination Category B-P requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric and pressure test), Reactor Building Normal Sump monitoring provides additional assurance that, in the event that leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the pressure testing (VT-2) examinations required by Section XI, and the leakage monitoring, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 59 of 71 Relief Request 11 ON 002 30.0 Weld #3-PIB1-8 30.1. ASME Code Component(s) Affected Unit 3 Reactor Coolant Pump 3B1 Casing Nozzle to Safe-End Weld #3-PIB1-8, Summary Number 03.B9.111.0060 30.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section XI, 1998 Edition through the 2000 Addenda 30.3. Applicable Code Requirement IWB-2500, Table IWB-2500-1, Examination Category B-J, Item Number B9.11 Figure IWB-2500-8 (c), 100% Volume Coverage of Examination Volume C-D-E-F 30.4. Impracticality of Compliance Component configuration:

  • Surface 1: Cast Stainless Steel Pump Casing* Surface 2: Stainless Steel Safe-end* NPS: 33.50 in.* Thickness:

2.330 in.Scanning requirements are described in 10CFR.50.55a (b)(2)(xv)(A)(1). The aggregate coverage was calculated from the following: 60° shear waves obtained 0% coverage in one axial direction (S1 -pump casing)600 shear waves obtained 50.0% coverage in one axial direction (S2 -safe-end)* 450 shear waves obtained 50% coverage in one circ. direction (CW).* 450 shear waves obtained5 0% coverage in one circ. direction (CCW).* The aggregate coverage was calculated to be (0% + 50% + 50% +50%)/4 =37.5%.In addition, a best effort examination was performed using 600 and 700 longitudinal waves to the extent possible in the upper 2/3 area of interest.The component limitation was caused by the cast stainless steel pump casing material. In order to scan all of the required volume for this weld, the component would have to be redesigned, which is impractical. Page 60 of 71 Relief Request 11 ON 002 The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. Therefore, the available coverage will not meet the acceptance criteria of this Code Case.30.5. Proposed Alternative and Basis for Use This weld was examined using procedures, equipment, and personnel qualified in accordance with ASME Section XI, Appendix VIII. No alternative examinations are planned for the weld during the current inspection interval.Radiography (RT) is not a desired option because RT is limited in the ability to detect service induced flaws. Additionally, radiography has not been qualified through performance demonstration. 30.6. Duration of Proposed Alternative This request is proposed for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.30.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 03.B9.11.0060 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section XI, 1998 Edition with the 2000 Addenda.The system leakage test performed each refueling outage in accordance with Table IWB-2500-1; Examination Category B-P requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric and pressure test), Reactor Building Normal Sump monitoring provides additional assurance that, in the event that leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the pressure testing (VT-2) examinations required by Section Xl, and the leakage monitoring, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 61 of 71 Relief Request 11 ON 002 31.0 Weld #3-PIB2-8 31.1. ASME Code Component(s) Affected Unit 3 Reactor Coolant Pump 3B2 Casing Nozzle to Safe-End Weld #3-PIB2-8, Summary Number 03.B9.11.0064 31.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section XI, 1998 Edition through the 2000 Addenda 31.3. Applicable Code Requirement IWB-2500, Table IWB-2500-1, Examination Category B-J, Item Number B9.11 Figure IWB-2500-8 (c), 100% Volume Coverage of Examination Volume C-D-E-F 31.4. Impracticality of Compliance Component configuration:

  • Surface 1: Stainless Steel Safe-end* Surface 2: Cast Stainless Steel Pump Casing* NPS: 33.50 in.* Thickness:

2.330 in.Scanning requirements are described in 10CFR.50.55a (b)(2)(xv)(A)(1). The aggregate coverage was calculated from the following: 600 shear waves obtained 50% coverage in one axial direction (S1 -safe-end)600 shear waves obtained 0% coverage in one axial direction (S2 -pump casing)* 450 shear waves obtained 50% coverage in one circ. direction (CW).* 450 shear waves obtained 50% coverage in one circ. direction (CCW).* The aggregate coverage was calculated to be (50% + 0% + 50% +50%)/4 = 37.5%.In addition, a best effort examination was performed using 60' and 700 longitudinal waves to the extent possible in the upper 2/3 area of interest.The component limitation was caused by the cast stainless steel pump casing material. In order to scan all of the required volume for this weld, the component would have to be redesigned, which is impractical. Page 62 of 71 ApDuke Site/Unit: Oconee / 2 Summary No.: 02.B9.11.0067 Workscope: ISl UT Pipe Wt 1 d Examination AITACHMENT h PAGE 2-7 OF 91 Outage No.: 02-23 Report No.: UT-08-141 Page: 1 of 4 Procedure: Procedure Rev.: Work Order No.: PDI-UT-2 C 01794421 Code: 1998 Cat./Item: B-J /B9.11 Location: Drawing No.: 2-53A-10

Description:

Valve 2LP-1 to Pipe System ID: 53A Component ID: 2-53A-10-3 Size/Length: N/A Thickness/Diameter: 1.125/12.0 SS Limitations: Yes -See Attached Limitation Report Start Time: 1401 Finish Time: 1430 Examination Surface: Lo Location: Inside F- Outside 21 9.1.1.1 Wo Location: Surface Condition: AS FOUND.Centerline of Weld Couplant: ULTRAGEL II MCNDE32825 Surface Temp.: 66.3 °F cAL 49 Batch No.: 07125 Temp. Tool Mfg,: D.A.S Cal. Report No.:.Angle Used 0 45 45T 60 Scanning dB 43,4 43.4 Indication(s): Yes ] No []Comments: FC 08-01, 08-04 Serial No.: CAL-08-147 60L j 81.2 Scan Coverage: Upstream [ Downstreamf[] CW 0./ CCW/Results: Accept ,E Reject []Percent Of Coverage Obtained > 90%: Info r] Initial Section XI Exam No Reviewed Previous Data: No ATIACRMWl P A 6E -2S- 0F ?, DUKE ENERGY COMPANY ISI LIMITATION REPORT Summary #: 02.B9.11.0067 Component ID 2-53A-10-3 remarks:[ NO SCAN SURFACE BEAM DIRECTION Due to Valve Configuration El LIMITED SCAN Z 1 E3 2 El 1 [] 2 N cw 5ý ccw FROM L N/A to L N/A INCHES FROM WO CL to Beyo,,,_ANGLE: 0 0 0 45 Dl 60 other FROM o DEG to 360 DEG ._i] NO SCAN SURFACE BEAM DIRECTION Due to Valve Configuration-LIMITEDSCAN i1 1 EE 2 [] cw -ccw FROM L N/A to L N/A INCHES FROM WO CL to Beyond ANGLE: El0 E 45 El 60 other 60L FROM 0 DEG to 360 DEG El NO SCAN SURFACE BEAM DIRECTION-LIMITED SCAN i1 -l2 1 El2-El cw [ ccw FROM L to L INCHES FROM WO to _ANGLE: El0 l 45 E3 60 other FROM DEG to DEG El NO SCAN El LIMITED SCAN SURFACE BEAM DIRECTION 01lFI E2[1 1 E- 2 0- cw -ccw S ketch(s) attached FROM L to L INCHES FROM WO to ANGLE: El 0 El 45 El 60 .. other FROM _ DEG to DEG Z yes-- No f Prepared By: Garland-X: 11-13-2008 .Sheet '2 of 4 Reviewed By: Date: Aut ze Insg c Date : -I L/C. Determination of Percent Coverage for UT Examinations -Pipe Site/Unit: Oconee / 2 Summary No.: 02.19.11.0067 Workscope: ISI Procedure: Procedure Rev.: Work Order No.: PDI-UT-2 C 01794421 Outage No.: 02-23 Report No.: UT-08-141 Page: 3- of 4 45 deg Scan 1 Scan 2 Scan 3 Scan 4% Length X% Length X 100.000 % Length X 100.000 % Length X% volume of length / 100 =% volume of length / 100 =50.000 % volume of length / 100 =50.000 % volume of length / 100 =% total for Scan 1% total for Scan 2 50.000 % total for Scan 3 50.000 % total for Scan 4 Add totals and divide by # scans 50.000 % total for 45 deg Other deg -60 (to be used for supplemental scans)The data to be listed below is for coverage that was not obtained with the 45 deg scans.Scan 1 Scan 2 Scan 3 Scan 4 100.000 % Length X 0.000 100.000 % Length X 50.000% Length X% Length X% volume of length / 100 =% volume of length / 100 =% volume of length / 100 =% volume of length / 100 =0.000 % total for Scan 1 50.000 % total for Scan 2% total for Scan 3% total for Scan 4 Percent complete coverage Add totals for each scan required and divide by # of scans to determine; 37.500 % Total for complete exam Site Field Supervisor Site Field Supervisor: Date: / ~Date: L-.jke Rhelvy Supplem, al Report AITACRMEN1 Page'.U -,j8-141 4 of 4 Summary No.: 02.69.11.0067 Examiner: Johnson, Garland Level: Il-N Examiner Level: -N Other: N/A Level: N/A Reviewerd Site Review ANII Rvtewe___ ___ ___ ___ ___ c~e ___ __Date ____Comments: Sketch or Photo: Z:\UT\lDOEALTProfileLine2.jpg PIPE -'::,7-I VuA LvL--FLOW, hýL,-! T cv <A.is r-11:>U S/I P AC E6 E PtiDuke Site/Unit: Oconee I 2 Summary No.: 02.C5.11.0005 Workscope: IS.UT Pipe WV,,d Examination Procedure: Procedure Rev,: Work Order No.: PDI-UT-2 9C 01794758 Outage No.: :02-23 Report No.: UT-08-139 Page: 1 of 6 Code: 1998 Cat./Item: C-F-1/C5.11 Location: Drawing No.: 2LP-150

Description:

Pipe to Valve 2LP-48 System ID: 53A Component ID: 2LP-150-17 Size/Length: N/A Thickness/Diameter: 1.125/10.0 SS Limitations: Yes -See Attached Limitation Report Start Time: 1056 Finish Time: 1117 Examination Surface: Inside 7 Outside Fv] Surface Condition: AS GROUND Lo Location: 9.1.1.1 Wo Location: Centerline of Weld Couplant: ULTRAGEL II Batch No.: 07125 Temp. Tool Mfg.: D.A.S Serial No.: MCNDE32825 Surface Temp.: 63 ýF Cal. Report No.: CAL-08-,141, CAL-08-142, CAL-08a`143 Angle Used 0 45 45T 60 60L I Scanning dB 34.3 34.3 49.4 62.8 Indication(s): Yes C No 7 Scan Coverage: Upstream Downstream F- CW 3 CCW Comments: FC 08-01, 08-04 Results: Accept D Reject EJ Info _-_ _Percent Of Coverage Obtained> 90%: No Reviewed Previous Data: Yes Examiner Level Ili-N .ý. IrS-gnat r" Date Reviewer Signature Date Stauffer, Lester, E. -11/11/2008 .Examiner Level Ii-N '- Signature Date Site Review Signature Date Howard, Dean M. t1111/2008 N/A O5ther Level N/A Signature Date JANIIe1w Sig Date N/A 11/11120081 ew1 A11ACHmEFI, A PASE 3-,- OF 91 ,JW Duke OEner-_qy-- Ultrasonic hiuication Report Site/Unit: Oconee Summary No.: 02.0C Workscope: 5.11.0005 Procedure: Procedure Rev.: Work Order No.: PDI-UT-2 C 01794758 Outage No.: 02-23 Report No.: UT-08-139 Page: 2 ot 6 IS'Search Unit Angle: 60L Wo Location: Weld Centerline I nI rc.tiinn" Q 1 1 1 Ce) Piping Welds C) Ferritic Vessels > 2"T C" Other C'L W1 MV2 7 MP Metal Path Wmax Distance From Wo To S.U. At Maximum Response RBR Remaining Back Reflection W I Distance From Wo At Of Max (Forward)L Distance From Datum W2 Distance From Wo At Of Max (Forward)Comments: FC 08-01, 08-04............. U~I ___Lo 132 1 I' NV2 Indication % W Forward Backward Li L L2 RBR Remarks Angle No. Of Max Of Max Of Max Of Max Of Amp.DAC W MP W. MPI W2 MP Max Max 60L 1 125 .80 2.027 N/A N/A N/A N/A N/A 350 N/A N/A Geometry-360' Continuous ..... ' " I, " J ' ....I ' ' ..Examiner Levl! ii'kN. Signature. Date Reviewer i Signature Date Stauffer, Lester. E. -"-, 11/-2008 // " /Date-Examiner Level 11.14 Signature Date Site Revi 4' Signature Date Howard, Dean M. _11/,11/2008. N/A Other Level N/A Signature Date ANL Review gnature Date N/A 11/11/2008 l g/~~ntre ATTACHMENT A PA6E33 Of (DUKE ENERGY COMPANY ISI LIMITATION REPORT Summary #: 02.C5.11.0005 Component ID 2LP-150-17 remarks: Z NO SCAN SURFACE BEAM DIRECTION No scan due to valve Li LIMITED SCAN { 1 7i 2 Li 1 [ 2 Z cw 0 ccw SurfaceI FROM L N/A to L :N/A INCHES FROM WO 0 to Beyond ANGLE: Li 0 [ 45 PQ60 other 60L FROM o DEG to 360 DEG Li NO SCAN SURFACE BEAM DIRECTION LIMITED SCAN -1 Lj 2 1 [j2 ] cwi] ccw FROM L to L INCHES FROM WO to _ANGLE: [3 0 Fl 45 Li 60 other FROM DEG to DEG i NO SCAN SURFACE BEAM DIRECTION LIMITED SCAN "1 E 22 1 i [-1 cw ] ccw FROM L to L INCHES FROM WO to ANGLE: Fi 0 [] 45 [3 60 other FROM DEG to DEG Li NO SCAN SURFACE BEAM DIRECTION Li LIMITED SCAN 1ii Li 2 1 l- 2 i cw c.cw FROM L to L INCHES, FROM WO to Sketch(s) attached ANGLE: [L 0 L] 45 Li 60 other FROM DEG to DEG 0 yes L No Prepared By: L. Staufeevel: Date: 11-11-2008 Sheet q of 6 Reviewed By: 6 Date: / , Authorized Inspector: --, Date:..... g (Jýj D uke Summary No.: 02.C5.11.0005 Examiner: Stauffer, Lester, Examiner: Howard, Dean M.Other: NIA Supplemental Report ATTACHMEN1 A PASE 3q Of g Report No.: UT-08-139 Page: 4 of 6 Level: IlI-N Level: II-N Level:. NA, Reviewer: Site Review: N/A Da ,e4 4z Dae ANtI Review: A 4-k A iL Date: Comments: Ind. #1 60L -Geometry Sketch or Photo, .UAT'0q,", I Vf-q -ý,VC.-- -ý.-VACZ I-T> "n C.A~ Summary No. 02-C5.1 1.0005 Examiner: Stautfer, Lester,~<i~'~. i Exami-ner, Hloward; Dean M Other: NIA Supplemee .Report P ABE 35 UF 3 1 Repon No.: U7T 39 Page. 5 of 6 Level: JIMN Level: I1-N Level: N/A Reviewer: Site Review: N/A-ANIt Review: Date, _____Pate: (~I 4, A~ -D 1 0r2~Z- C \dýe 61 N(D ,- -OL -ezýeA Z3:--' --.Z~Yt5r'-Q~~~ C 30k 6O i ukDie Determination of Percent Coverage for UT Examinations -Pipe Site/Unit: Oconee ! 2 Summary No.: 02.C5.11,0005 Workscope: ISI Procedure: Procedure Rev.: Work Order No.: PDI-UT-2 C 01794758 Outage No.: 02-23 Report No.: UT-08-139 Page: 6 ot 6 to 45 deg Scan 1 Scan 2 Scan 3 Scan 4 100,000 % Length X 100.000 % Length X 100.000 % Length X 100.000 % Length X 0.000 50.000 50.000 50.000% volume of length / 100 =% volume ot length / 100 =% volume of length / 100 =% volume of length / 100 =0.000 50.000 50.000 50.000% total for Scan 1% total for Scan 2% total for Scan 3% total for Scan 4 Add totals and divide by # scans = 37.500 % total for 45 deg Other deg -_ (to be used for supplemental scans)The data to be listed below is for coverage that was not obtained with the 45 deg scans, Scan 1 Scan 2 Scan 3 ,Scan 4% Length X% Length X% Length X% Length X% volume of length /100 =% volume of length / 100 =% volume of length / 100 =% volume of length / 100 =% total for Scan 1% total for Scan 2% total for Scan 3% total for Scan 4 Percent complete coverage Add totals for each scan required and divide by # of scans to determine; 37.500 % Total for complete exam Site Field Supervisor: SieFil Sprisr Dio Da ( e.- I I ýj 'f 10 ? AITAC MM EN 'T PAfiE31 OF 81 Site/Unit: Oconee / 2, Summary No.: 02.C5.11.0021 Workscope: ISI UT Pipe Wt-id Examination Procedure: Procedure Rev.: Work Order No.: PDI-UT-2 C 01795191 Outage No.: 02-23 Report No.: UT-08-156 Page: 1 of 4 Code: 1998 Cat./Item: C-F-1/C5.11 Location: Drawing No.: 2LP-217

Description:

Valve 2LP-178 to Pipe System ID: 53A Component ID: 2LP-217-8 Size/Length: N/A Thickness/Diameter: 1.0/10.0SS Limitations: Yes -See Attached Limitation Report Start Time: 0940 Finish Time: 1014 Examination Surface: Inside D Outside ., Surface Condition: AS GROUND Lo Location: 9.1.1.1 Wo Location: Centerline of Weld Couplant: ULTRAGEL II Batch No.: 07125 Temp. Tool Mfg.: D.A.S Serial No.: MCNDE32824 Surface Temp.: 69 °F Cal. Report No.: CAL-08-1:64, CAL-08-165, CAL-08-166 Angle Used 0 t45 45T 60t 60L 1 Scanning dB E 31.0 31.0 51.0 58 Indication(s): Yes [.1 No j Scan Coverage: Upstream j Downstream LJ CW S) CCW 0 Comments: FC 08-01, 08-04 Results: Accept E Reject F Into J.7 Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes Examiner Level uIl-N Siaiure -Date Reqyiver A Signature Date S t a u ff e r , L e s t e r , E .1 1 / 1 3 / 2 8 q D Examiner Level It-N .Sianature Date Site Review Signature Date Hollis, Jacob 1 / 11/13/2008 N/A -Other Level N/A Signature Date ANII Rev ew ,,.., Signpi ure Date N/A 11/13/2008 -J 5ZA~/K~~4>d4~LC / &M.Limitation Record SiteiUnit: Oconee I 2 nary No.: 02.CS.11.0021 Workscopeý 1S Proceduro: Procedure Rev.: Work Order No.: PDI-IUT-2 01795191 Outage No.: Report No.: 02-23 UT-08-1 55 Page: 2. of 4 Description ol Limitation: Limitation due to valve configuration. LU-*.! belch ol Limitation: t- C.--J L f I I-Q~o~a CiW -0 /10 t I.: Limitations removal requirements: Radiation lield: Examiner Level 111-N Signature Date Fevi. r Signature .ate Stauffer, Lester, E. Date..1I1I~o Fl. Signture Examiner Level II-N Signatur Date Sile Review Signature Date Hisot , J,,ob 111131200 8 I wA Other Level NIIA Signature Date ANtI Ieview Sgn aI N/A 1111312008 / Ck$44 ~ ~ ifi-WOuke r&Energy-Determination of Percent Coverage for UT Examinations -Pipe Site/Unit: Oconee / 2 Summary No.: 02.C5.11.0021 Workscope: ISI Procedure: Procedure Rev.: Work Order No..PDl-UT-2.C 01795191 Outage No.: 02-23 Report No.; UT-08-156 Page' 3 of 4 Lý! C=3 45 deg Scan 1 Scan 2 Scan 3 Scan 4% Length X% Length X 100.000 % Length X 100.000 % Length X% volume of length 1 100 =% volume of length / 100 =50.000 % volume of length 1100 =50.000 % volume of length 1100 =% total for Scan 1% total for Scan 2 50.000 % total for Scan 3 50.000 % total for Scan 4 Add totals and divide by # scans = 50,000 % total for 45 deg Other denq -60 (to be used for supplemental scans)The data to be listed below is for coverage that was not obtained with the 45 deg scans.Scan I Scan 2 Scan 3 Scan 4 100.000. % Length X 50.000 1.00.000 % Length X 0.000% Length X....__% Length X% volume of length /100 = 50.000% volume of length /100 = .000% volume of length /100 =% volume of length /100 =% total for Scan 1.% total for Scan 2% total for Scan 3% total for Scan 4 Percent complete coverage Add totals for each scan required and divide by # of scans to determine; 37.500 % Total for complete exam Site Field Supervisor: ii I//I,,..Site Field Supervisor: Dale: .L14LI~tQ.~ Date: /I q /0 AIIACHMENT A PA6E /4O OF Y/DUKE ENERGY COMPANY ISI LIMITATION REPORT _Summary #: 02.C5.11.0021 Component ID 2LP-217-8 remarks: Z NO SCAN SURFACE BEAM DIRECTION [N- duc I) VaJve Fl LIMITED SCAN El 1 [ 2 [ 1 El 2 N cw ccw Conf-iourauon FROM L N/A to L N/A INCHES FROM WO CL to: Bcond ANGLE: 0l 0 i 45 Z 60 other 60L FROM o DEG to 36o DEG El NO SCAN SURFACE BEAM DIRECTION I El LIMITED SCAN El E 2 El1 El 2 cw El ccw FROM L to L INCHES FROM WO to _ _ANGLE: El 0 El 45 El 60 other FROM DEG to 'DEG LI NO SCAN SURFACE BEAM DIRECTION 1.-LIMITED SCAN E] 1 E2 El- 1 L2 cw [ccw I FROM L to. L INCHES FROM WO to .._ANGLE: ED 0 El 45 El 60 other FROM DEG to DEG El NO SCAN SURFACE BEAM DIRECTION'- LIMITED SCAN l1 -- 2 Eli 2l Elcw E- ccw FROM L to L INCHES FROM WO to Sketch(s) attached ANGLE: El 0 [E 45 El 60 other FROM DEG to DEG C yes El No Prepared By: LL. Stauff. .L-,el: ii, Date: 11-)3-2008 Sheet 4 of 4 Reviewed By: Dale: Authorize Inspector: Date . AITACHMENT A PABE41 OF 81 Duk Site/Unit: Oconee / 2 Summary No.: 02.C5.11.0025 Workscope: is[UT Pipe WVd Examination Procedure: P Procedure Rev.: Work Order No.: 0'DI-UT-2 C 1794767 Outage No.: 0.2-23.Report No.: UT-08-138 Page: 1 of 6 Code: 1998 Cat./Item: C-F-1/C5.11 Location: Drawing No.: 2-53A-9

Description:

Pipe to Valve 2LP-48 System ID: 53A Component ID: 2-53A-9-16 Size/Length: N/A Thickness/Diameter: 1.00/10.0 SS Limitations: Yes -See Attached Limitation Report Start Time: 1038 Finish Time: 1055 Examination Surf Lo Location: Temp. Tool Mfg.: Cal. Report No.: Angle Used Scanning dB Indication(s): Comments: FC 08-01, 08-04 ace: Inside E 9.111.1 Outside [Wo Location: Surface Condition: AS GROUND Centerline of Weld Couplant: ULTRAGEL II P.: 63 0 F Batch No.: 07125 D.A.S Serial No.: MCNDE32825 Surface Ten CAL-08i 41, CAL-08142. CAL;:08-143 .0 45 45T1 60 60L " 34,3 34.3 49.4 1 62.8. ..Yes 17 No 7 Scan Coverage: Upstream[ ] Downstrearr R CW E CCWIZ Results: Accept F] Reject F Percent Of Coverage Obtained > 90%: info 3 No Reviewed Previous Data: Yes A71ACHMEN1 A PASE #L 2 OF P~uke (rnergy Ultrasonic i1,lication Report Site/Unit: Oconee /Summary No.: 02.Cl Workscope: 2 5.11.0025 Procedure: Procedure Rev.: Work Order No.: PDI-UT-2 C097 01794767 Outage No.: 02-23 Report No.: UT-08-138 Page: 2 of 6 ISI Wo%lyax Search Unit Angle: 60L Wo Location: Weld Centerlilne L A, 0 1 1 1 (ý) Piping Welds 0 Ferritic Vessels > 2"T (Th Other MP Metal Path Wmax Distance From Wo To S.U. At Maximum Response RBR Remaining Back Reflection W1 Distance From Wo At Of Max (Forward)L Distance From Datum W2 Distance From Wo At Of Max (Forward)Comments: FC 08-01, 08-04 CL W1 W2----~------ -ý--OIV,-- A ------- --_-_-.....lien~Indication % W Forward Backward LI L L2 RBR Remarks Angle No. Of Max Of Max Of Max Of Max Of Amp.DAC W MP WI MP W2 MP Max Max 60L 1 125 .80 2.10 N/A N/A N/A N/A N/A 360 N/A N/A Geometry -360 Continuous Stauffer, Lester, E. 1/120 Howard, Dean M. 1/120 /Othe Leel NA Sgnature Date* ANII Reve S i o{iure Date6 NIA 1/1 J208 I ý-..... : " " " " " ' ' !" ....' ..... Supplemt-,al Report V Energy.AT TACHMEN1 A MAE Z/3 OF 9I Reporl No.: UT-08-138 Page: 3 of 6 Summary No.: 02.C5,11.0025 Examiner: Stauffer, Lest 'Examiner: Howard, Dean M..Other: N/A PUL~4111MO Level: IlI-N Level: I1-N Level: N/A Reviewer: Site Review: ANII Review: ,N/A, 4, Date:/ (6 Dale:______ Dale: ________2 Comments: Ind. #1 60L -Geometry -Sketch or Photo: Z:\UT\ICODEAL\ProieLine2.ipg £ccc. ~ --ri-~ ~- -'4)~ 0..,¶ r V A LýO ANN -AWj*ATIACHMENT A Suppleme I Report 4 I 1# OF Report No.: U 138 Page: 4 of 6..Summary No.: 02.C5.11.0025 Examiner: Stauffer, Lse Examiner: Howard, Dean Other: NIA Level: I1l-N Level: li-N Level: N/A Reviewer: Site Review: NIA ANII Review: Date: 0 Date: Dale: Comments: AJ'5o rI~tAx nEAc~ -'r~-Jo nQ 4~~5 S? -\'Al~/L$~&O~J(IO&) ~ 0 4 A~AC* d~ftf~ (-) mv 9~~j e.' -) 7 C :5, 1/, CCV- -4"r ý Iýý " -ta (I Al I ACHMI 1A PAFE qS OF ý t DUKE ENERGY COMPANY ISI LIMITATION REPORT Summary #: 02.C5.11.0025 Component ID 2-53A-9-16 remarks: Z NO SCAN SURFACE BEAM DIRECTION No scan due to valve on El LIMITED SCAN 0'- 1 2 Z 1 [-] 2 Z cw Z ccw surface2.FROM L N/A to L N/A INCHES FROM WO0 to Beyond ANGLE: El 0 Z 45 Z 60 other 60L FROM o DEG to 360 DEG El NO SCAN SURFACE BEAM DIRECTION E] LIMITED SCAN Eli El 2 -- 1 E 2 El cw El ccw FROM L to L INCHES FROM WO to ._.!ANGLE: El 0 Fl 45 Fl 60 other FROM DEG to DEG El NO SCAN SURFACE BEAM DIRECTION ElLIMITED SCAN l2 El 1 1 2 Elc w 0 ccw FROM L to L INCHES FROM WO to ANGLE: El 0 El 45 l 601 other FROM., DEG to DEG El NO SCAN El LIMITED SCAN SURFACE Fi 1 [12 BEAM DIRECTION El 1 El 2 El cw El ccw FROM L to L INCHES FROM WO to ANGLE: 0 45 Fý 60 0 Sketch(s) attached E yes El No ther FROM __ DEG to_ DEG, Deter Site/Unit' 'Oconee I 2* Summary No.: 02.C5.11.0025 --tWorkscope: ISt mination of Percent Coverage for UT Examinations -Pipe Procedure: Procedure Rev,: Work Order No.: PDI-UT-2 C 01794767 Outage No.: 02-23 Report No.: UT-08-138 Page: 6 of 6 45 de1%Scan 1 100.000 % Length X Scan 2 100.000 % Length X Scan 3 100.000 % Length X Scan 4 100.000 % Length X 50.000 % volume of length / 100 =0.000 % volume ol length /100 =50.000 % volume of length 1100 =50.000 % volume of length / 100 =50.000 % total for Scan 1 0.000 % total for Scan 2 50.000 % total for Scan 3 50.000 % total for Scan 4 Add totals and divide by # scans = 37.500 % total for 45 deg Other deg -(to be used for supplemental scans)The data to be listed below is for coverage that was not obtained with the 45 deg scans.Scan 1 Scan 2 Scan 3 Scan 4% Length X_% Length X% Length X% Length X% volume of length / 100 =% volume of length / 100 =% volume of length / 100% volume of length / 100 =% total for Scan 1% total for Scan 2% total for Scan 3% total for Scan 4 Percent complete coverage Add totals for each scan required and divide by # of scans to determine; 37.500 % Total for complete exam Site Field Supervisor: J/07~ ? i~Date: Note- 600 RL scan not included in percentage coverage due to requirements of lOCFR50.55a(b)(2)(xv)(A)(1). Best effort scan with 60° RL obtained 50% coverage in or~e axial direction. A-,fke UT Base Met .amination W En ergy.A11ACHMNt~ PA6E ýJOf 81 Site/Unit: Summary No.: Workscope: Oconee / 2 02.C5.11.0034 Procedure: Procedure Rev.: Work Order No.: NDE-640 04 01795187 Outage No.: N/A Report No.: BOP-UT-08-036 Page: 1 of 2 ISI / 2EOC23 Code: 1998/2000 Addenda Cat./Item: N/A Location: N/A Drawing No.: 2LP-189

Description:

Pipe to Elbow System ID: 53A Component ID: 2LP-189-14 Size/Length: N/A Thickness/Diameter: 1.0 / 10.0 SS Limitations: None Start Time: 1034 Finish Time: 1038 Examination Surface: Inside 3 Outside 1 Surface Condition: GROUND Lo Location: 9.1.1.1 Wo Location: Centerline of Weld Couplant: ULTRAGEL II Batch No.: 07125 Temp. Tool Mfg.: Lutron Serial No.: MCNDE32795 Surface Temp.: 63 OF Scanning dBi 50 Cal. Report No.: CAL-08-160 % Amplitude Position One Position Max Position Two Ind.Loss % -. Remarks No.Back Wall Full Screen Li W1 W2 MP LM Wi W2 MP L2 W1 W2 MP NRI Comments: Results: Accept or Reject L] Info [ Initial Section XI Exam Percent Of Coverage Obtained > 90%: Yes Reviewed Previous Data: No-..DaExaminer Level 11-N >.3gnure Date Reviewer Signature Date Leeper, Winfred C. 11/17/2008 .',.( De Examiner Level U.N ... / lu. e Date Site Review Signature Date, Howard, Dean M. 11/1712008 N/A Other Level N/A Signature Date AW Review ignature Date N/A 11/1712008 ./ -. / // yC< Duke Summary No.: 02.C5.11.0034 Examiner: Leeper, Winfred C. ")JIA,> " Examiner: Howard, Dean M.Y;t7 Other: N/A uppleme,,lal Report AIIACHMEN, A PA 6E0Z OF Report No.: BOP-UT-08-036 Page: 2 of 2 Level: It-N Level: I1-N Level: N/A Reviewer: Site Review: N/A ANII Review: / yZ " Date: I1" Date: Date: Comments: Sketch or Photo: Z:\UT'IDDEAL\ProfileLine2.jpg o0>C e z-1% .--- ,0 O >O , ) 0 A11AttMk PAE 1/9 OF 8 Site/Unit: Oconee / 2 Summary No.: 02.C5.11.0034 Workscope: ISt UT Pipe Weid Examination Procedure: Procedure Rev.: Work Order No.: PDI-UT-2 C 01795187 Outage No.: 02-23 Report No.: UT-08-155 Page: 1 of 5 Code: 1998 Cat/Item: C-F-1/C5.11 Location: Drawing No,: 2LP-189

Description:

Pipe to Elbow System ID: 53A Component ID: 2LP-189-14 Size/Length: N/A Thickness/Diameter: 1.0 / 10.0 SS Limitations: Yes -See Attached Limitation Report: Start Time: 1040 Finish Time: 1110 Examination Surface: Inside -Outside [ Surface Condition: GROUND Lo Location: 9.1.1.1 Wo Location: Centerline of Weld .... Couplant: ULTRAGEL II Batch No.: 07125 Temp. Tool Mfg.: Lutron Serial No.: M.CNDE32795 Surface Temp.: 63 °F Cal. Report No.: "CAL-08-161, CAL-08-162. CAL-68-163. Angle Used 0 45 .45T 60 60L. l Scanning dB 36 36 52 49.Indication(s): Yes ] No E/) Scan Coverage: Upstream [ Downstream L CW 0/ CCW Comments: FC 08-01, 08-04 Results: Accept "] Reject [] Info Initial Section XI Exam Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: No Examiner Level Il-N Signalure Date Reviewer Signature Howard, Dean M. /Sr11 /17/200.8 fate Examiner Level Il-N 2..tgn ure Date Site Review Signature Date Leeper, Winfred C. IA- /" -. -11/17/2008 N/A Other Level N/A Signatdre Date ANII R view .,, .. <,-Sgnau$. ,. Date N/A 11/17/2008 .. Q (-.Y ,--- , i/"' AIIACHMEN /1 P A r rl6 A Fi ~(DUKE ENERGY COMPANY ISf LIMITATION REPORT Summary#: 02.C5.11.0034 Component ID 2LP-189-14 remarks: j NO SCAN SURFACE BEAM DIRECTION i Due to Permancn, H'ngecr D LIMITED SCAN [1 112 []1 2 [cw ccw .FROM L -3.0" to L +3.0" INCHES FROM WO 5' to Beyond _ _ _ANGLE: fl 0 Z 45 Z 60 other FROM N/A DEG to N/A DEG.[ NO SCAN SURFACE BEAM DIRECTION Due to Perament Hanger[] LIMITED SCAN [1 22 Z cw [] ccw FROM L 14.875 to L 21 87 INCHES FROM WO " to Beyond ANGLE: [1 0 Z 45 60 other FROM N/A DEG to N/A DEG 17 NO SCAN SURFACE BEAM DIRECTION LI LIMITED SCAN r- 1 -2 Ei 1 2 Dcw fj]ccw FROM L to L INCHES FROM WO 'to ANGLE: ..- 0 E] 45 [3 60 other FROM _ DEG to 6 DEG NO SCAN[- LIMITED SCAN SURFACE BEAM DIRECTION r--1 1 -2 0 1 [1 2 D cw [] ccw FROM L ANGLE: to L 10[1 45 INCHES FROM WO to 11 60 other__ FROM _ DEG to _ DEG Sketch(s) attached Z yes[] No Prepared By: Winfred Leeper Reviewed By: rO-Ene.igy-AI IACHMENT A Supplemn-. .tal Report PABEg5"/ OF 31 Reportl N .: UT-08-155 Page: 3 of 5: Summary No.ý 02.C5.11.0034 Examiner, Howard, Dean M. -Examiner Leeper, Winfred C.Othec N/A Z Level: ti-N Level: Il-N Level: N/A Reviewer: 2,., Site Review: N/A AN II Review: A Date.Dae:'Comments: Sk~etchi or Pholo: ZAUT'iDDEALProfiils~ne2.jpg PLýZ WLAA/& AlT 4A&A~6ftZ'. gL. 0 C3-f&L~iA I I II Summary No.: 02,C5.11.0034 Examiner: Howard, Dean M. .A '. .Examiner Leeper, Winfred C. .Other: N/A Supplemental Report Report No.Page: Level: Il-N Level: I1-N Level: N/A Reviewer: I-Site Review: N/A ., ANtI Review: --{.ATTACHMENT , P A6E 51 OF gI UT-08-155 4 of 5 Daie.Date.Date .______Comments: A Wý-(-a R r/ ?Z(( h,<2 -/ (/Sketch or Pholo:-.z I VI':3,"A I. Determination of Percent Coverage for, UT Examinations-Pipe Site/Unit: Oconee I 2 Procedure: PDI-UT-2 Outage No.: 02-23" Summary No.: 02.C5.11.0034 Procedure Rev.: C Report No.: UT.08-155 Workscope: ISI Work Order No.: 01795187 Page: 5 of 5 45dea Scan A' 61.500 % Length X 100.000 % volume of length /100 = 61.500 % total for Scan 1 Scn- ' d ScanZ3 61.500 % Length X 100.000 % volume of length /100 = 61.500 % total for Scan 2 Scan 3 38.500 % Length X 50.000 % volume of length / 100 = 19.250 % total for Scan 3 Scan 4 38.500 % Length X 50.000 % volume of length / 100 = 19.250 0/ total for Scan 4 Add totals and divide by # scans = 40.375 % total for 45 deg Other den -60 (to be used for supplemental scans)The data to be listed below is for coverage that was not obtained with the 45 deg scans.Scan 1 61.500 % Length X 100.000 % volume of length / 100 = 61.500 % total for Scan 1 Scan 2 61.500 % Length X 100.000 % volume of length / 100 = .61.500 % total for Scan 2 Scan 1' 38.500 % Length X 0.000 % volume of length 100 = 0.000 % total for Scan 3 Scanf 38.500 % Length X 50.000 % volume of length / 100 = 19.250 % total for Scan 4 Percent complete coveraqe Add totals for each scan required and divide by # of scans to determine; r ...969.. % Total for complete exam Site Field Supervisor: 1/4,at Date: S.& K f AI1ACHMENT PAGE_5q OPE)Site/Unit: Oconee / 2 Summary No.: 02.C5.11.0036 Workscope: ISI UT Pipe W-vid Examination Procedure: Procedure Rev.: Work Order No.: N DE-600 17 01794767 Outage No.: 02-23 Report No.: UT-08-164 Page: 1 of 5 Code: 1998 Cat./Item: C-F-1/C5.11 Location: Drawing No.: 2LP-215

Description:

Pipe to Flow Restrictor System ID: 53A Component ID: 2LP-215-17 Size/Length: N/A Thickness/Diameter: 1.0/10.0SS Limitations: Yes -See Attached Limitation Report SizeLenta N/A ThiknesshTimeter: 105 Examination Surface: Inside [ Outside Surface Condition: AS GROUND Lo Location: 9.1.1.1 Wo Location: Centerline of Weld Couplant: ULTRAGEL II Batch No.: 07125 Temp. Tool Mfg.: Lutron Serial No.: MCNDE32795 Surface Temp.: 51 0 F Cal. Report No.: C.AL-08-182, CAL-081 83, CAL-08-184 Angle Used 0 45 45T 60 60L Scanning dB 45 60 40 Indication(s): Yes Ml No 7v Scan Coverage: Upstream []j Downstream D CW [] CCW Comments: FC 08-03 Results: Accept E Reject Into !--I _Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes Examiner Level ti-N Signature Date Reviewer H o u se r, G a yle E .1.1 /2 0 at r D ate,:.. , M F ' ,t -I -o <Examiner Level N/A Signature Date *Site Reiew v..Siatiie Date N/A 11/19/2008 N/A Other Level N/A Signature Dat e ANII ReaI yS'te N/A..11/19/2008 ale. AlTTACHMENT A PAUE S5 OF ý31 DUKE ENERGY COMPANY ISI LIMITATION REPORT __Summary#: 02.C5.11.0036 Component ID 2LP-215-17 remarks: Z NO SCAN SURFACE BEAM DIRECTION No scan due :o cast D LIMITED SCAN 1 1 ED 2 1 N 2 Z cw [E ccw flow constrictor. FROM L N/A to L N/A INCHES FROM WO to _I ANGLE: El 0 0 45 Z 60 other 60L FROM o DEG to 360 DEG[ NO SCAN SURFACE BEAM DIRECTION No scan due to I-LIMITED SCAN 0 1 Z 2 l 1 7 2 El cw " ccw coupling welded in FROM L 6.35" to L 9.35" INCHES FROM WO 2.5 to N/A the area of interest.ANGLE: fl 0 E] 45 B 60 other 60L FROM N/A DEG to N/A DEG D] NO SCAN SURFACE BEAM DIRECTION DLIMITED SCAN 0 1 1 22 i 1 727cw ccw FROM L to L INCHES FROM WO to___ANGLE: [1 0 [] 45 0 60 other___ FROM __ DEG to DEG-- NO SCAN IZ LIMITED SCAN SURFACE BEAM DIRECTION[11 02 E- 1 7 2 r cw 7 ccw FROM L ANGLE: to L INCHES FROM WO to 7 0 IE 45 0,160 /qther ... .FROM DEG to ..... DEG Sketch(s) attached[ yes-' No Prepared By: Gayle Houser I Reviewed By: PLDUke 4Wrg Suppleme,,tal Report Report No.: Page: ATTACHMENT A PAGE !9(P OFýýUT-08-164 3 of 5;Summary No.: 02.C5.11.0036 Examiner: Houser, Gayte E.Examiner: N/A Other: N/A Level: Il-N Level: N/A Level: N/A Reviewer: ~5 y,,-4-4~Dale: Site Review: N/A /. Date_ANI, Review: Date: Xa Comments: M&W c # ., tr-;i7 A ýý ' 7ý I I.-K, I ")(r -S' ý ý, -,., " -q Sketch or Photo: o ý5 "- 3,L!.x' C, ATIA~hMENi A PA6E,57 OF 9 A% Dike 0zhergy-Suppleme..,al Report Report No,: U. jA-164 Page: 4 of 5 Sumnmary No.: 02.CS.11t0036 Exarnine.' Houser, Gayle E.E.xarmner N/A O:ne,: N/A Level: t'-N Level: N/A Level: N/A.Reviewer: D fw-/. ate: /o-us~Sile Review: NADate:______ ANiIRviw Dale:_____ Commentls- -7 ~i.Sketch or Photo: V ~ 6o* 1* '4.-~m (~4(r6L.2j'L, I-~5 ~8/O7 C' 1.- -KY).!I /~ /11 " .-- D~uke Deter 0 E~nery'.,, Vn Site/Unit: Oconee I 2-- u=,Summary No.: 02.C5.11.0036" Workscopeo ISI mination of Percent Coverage for UT Examinations -Pipe Procedure: Procedure Rev.: Work Order No.: NDE-600 17 01794767 Outage No- 02-23 Report No.: UT-08-1 64 Page: 5 ol f 45 degi Scan 1 Scan 2 Scan 3 Scan 4% Length X% Length X 100.000 % Length X 100.000 % Length X 50.000 50.000% volume ol length I 100 z% volume ol length / 100 =% volume of length / 100 =% volume of length I 100 =50.000 50.000% total for Scan 1% total for Scan 2% total for Scan 3% total for Scan 4 Add totals and divide by # scans = 50.000 % total for 45 deg Other deq -60 (to be used lor supplemental scans)The data to be listed below is for coverage that was not obtained with the 45 deg scans.Scan 1 100.000 Scan 2 91.000 Scan,32 9.000 Scan 4% Length X 0.000% Length X 50.000% Length X 19.300% Length X% volume of length / 100 = 0.000% volume ol length / 100 = 45.500% volume ol length / 100 = 1.737% volume of length / 100 =total Ito Scab 1% total [of Scan 2:% total lor Scan 3% total lo: Scan Percent complete coverage Add totals for each scan required and divide by t ol scans to determine; 2-o44:7 %Total for complete exam Site Field Supervisor: .6 Date: AT IAt~khl PAH5Ef OF S[Duke Site/Unit: Oconee / 2 Summary No.: 02.C5.11.0067 Workscope: ISI UT Pipe Wtvd Examination Procedure: Procedure Rev,: Work Order No.: PDI-UT-2 01795191 Outage No.: 02-23 Report No.: UT-08-157 Page: 1 of 4 Code:. 1998 Cat./Item: C-F-1/C5.11 Location: Drawing No.: 2LP-218

Description:

Pipe to Valve 2LP-176 System ID: 53A Component ID: 2LP-218-23 Size/Length: N/A Thickness/Diameter: 1.0/10.0 SS Limitations: Yes -See Attached Limitation Report Start Time: 1022 Finish Time: 1044 Examination Surface: Inside L- Outside ov Surface Condition: AS GROUND Lo Location: 9.1.1.1 Wo Location: Centerline of Weld Couplant: ULTRAGEL II Batch No.: 07125 Temp. Tool Mfg.: D.A,S Serial No.: MCNDE32824 Surface Temp.: 63 ýF Cal. Report No.: CAL-08-164, CAL,08-165, CAL-08-166 AngleUsed

0. 45 45T 60 60L, Scanning dB 35.7 .35.7 46.4 52 indication(s):

Yes ] No No[ Scan Coverage: Upstream 0] Downstream [J CW W CCW [/Comments: FC 08-01, 08-04 Results: Accept [ Reject R Info D__, Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes Examiner Level 1. N S' Date Reviewer Signature Date Hollis, Jacob 11/13/2008: .A ' .. .Examiner Level ill-N .Siqnature Date Site Review / Signature Date Stauffer, Lester, E, .-' 11/13/2008 N/A Other Level N)*A Signature Date ANII eview -.(" Sigýre W 6ate N/A 1/3/208'/& &M-W.Limitation Record Sile(uriit: Oconee 1 2 iiary No.. D2.CS. 11.0067 Procedure: Procedure Rev.-Work Order No.: PDI-UT-2 C 01795191 Outage No,: 02-23 Report No.: UT-08-157 Page: 2 of 4 Wockscope: Description of Limitation: Limitation due to valve configuration. ,-&- =Sketch ol Limilation: F ii __/13'W 0 ...AR9-,Ik n1 <1 fhf'S I~A&E1L~iL Radiation lield: Examiner -Level 11-N Si atuf -- Date Reviewero Signate " Date Examiner Leve l Z r. ..Signature -Date Site 'Re 'view Signature Dale S.. r .Lte .o .11t'31200B N'A Other Level I Signature sign re Date Staufr Leser,'MA2008 r.4AiAIL ate 'lie M& Duke P-0-Energy. Determination of Percent Coverage for UT Examinations -Pipe Site/Unit Oconee 1 2 Summary No,; 02.C5.11.0067 Workscope: ISI Procedure: PrauidUre Rev.Worfk Order No-PDI-UT-2 C 01795191 Outage No.: 02-23 Report No.: UT-08-157 Page: 3 of 4 U"-C 45 deg Scan I Scan 2 Scan 3 Scan 4% Length X% Length X 100.000 % Length X 100.000 % Length X% volume of length 100 =% volume of length / 100 =50.000 % volume of length/ 100 =50.000 % volume of length / 100 =% total for Scan 1% total for Scan 2 50.000 % total for Scan 3 50.000 % total for Scan 4 Add totals and divide by # scans = 50.000 % total for 45 deg Other deg -60 (to be used for supplemental scans)The data to be listed below is for coverage that was not obtained with the 45 deg scans.Scan 1 Scan 2 Scan 3 Scan 4 100.000-100.000% Length X 50.000% Length X 0.000% Length X" Length X" volume of length I 100 =" volume of length /100 =" volume of length 1 100 =" volume of length /100 =50.000 0.000.-% total for Scan 1% total for Scan 2" total for Scan 3% total for Scan 4 Percent complete coverage Add totals for each scan required and divide by # of scans to determine; 37.500 % Total for complete exam Site Field Supervisor: ,-2........... j Date. (JI It 1 60F PA6E O'-fF DUKE ENERGY COMPANY _ISI LIMITATION REPORT __Summary #: 02.C5.11.0067 Component ID 2LP-218-23 remarks:[ NO SCAN SURFACE BEAM DIRECTION No Scandue to Valve r- LIMITED SCAN [ 1 [l 2 [- 1 (E 2 0 cw 0 ccw Configuration FROM L N/A to L N/A INCHES FROM WO CL to Beyond !ANGLE: D 0 45 [ 60 other 6oL FROM o DEG to 360 DEG El NO SCAN SURFACE BEAM DIRECTION _______El LIMITED SCAN E] 1 -2 Eli 2 7 ecw [ccw FROM L to L INCHES FROM WO to _.ANGLE: D 0 R 45 Fl 60 other FROM DEG to .-. DEG E- NO SCAN SURFACE BEAM DIRECTION Dl LIMITED SCAN 1 i ]' 2 E"1 2 Dcw FROM L to.L____ _ INCHES FROM WO to ANGLE: El 0 rl 45 El 60 other ... FROM DEGto __ DEG El NO SCAN El- LIMITED SCAN SURFACE: BEAM DIRECTION Di "1E2 Di1 72D7cw 7 ccw FROM L ANGLE:_0 [4 6 ttoLer DODý 45 Dý60 other INCHES FROM WO.to FROM ... DEG to DEG Sketch(s) attached Z yes F-1 No Prepared By: L. Stauff w: F ... .* !'" I Al IACHMEN

  • A MAE &5~ OF F I Duke, Site/Unit:

Oconee / 2 Summary No.: 02.C5.21.0027 Workscope: ISI UT Pipe Wed Examination Procedure: Procedure Rev.: Work Order No.: PD I-UT-2 C 01795251 Outage No.: 02-23 Report No.: UT-08-127 Page: 1 of 6 Code: 1998 Cat./item: C-F-1/C5.21 Location: Drawing No.: 2-51A-28 (1)

Description:

Pipe to Flange System ID: 51A Component ID: 2-51A-28-15 Size/Length: N/A Thickness/Diameter: 0.531/ 4.0" Limitations: Yes -See Attached Limitation Report Start Time: 0940 Finish Time: 1030 Examination Surface: Inside [ Outside [] Surface Condition: GROUND FLUSH Lo Location: 9.1.1.1 Wo Location: Centerline of Weld Couplant: ULTRAGEL II Batch No.: 07125 Temp. Tool Mfg.: Lutron Serial No.: MCNDE32795 Surface Temp.: 78 -F Cal. Report No.: CAL-08-125. CAL-08-126, CAL-08-127 Angle Used 0 5 45T 60I 650 Scanning dB 30 30 44 55 Indication(s): Yes j No Scan Coverage: Upstream L Downstream L CW j] CCW D Comments: FC 08-01, 08-04 Results: Accept I Reject [] Info F]Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes PAGE 6:q OF ý? I Duke 4~Eneryy.Ultrasonic h.dication Report Site/Unit: Oconee Summary No.: 02.,C Workscope: 2, 5.21.0027 ISI Procedure: Procedure Rev.: Work Order No.: PDD!-UT-2 01795251 Outage No.: 02-23 Report No.: UT-08-127 Page: 2 Of 6 Search Unit Angle: 45 & 60 Wo Location: Weld Centerline r , I ocation' 0 1 I -(' Piping Welds Ferritic Vessels > 2"T Other Wo \Vn;CL WI N1.1 2 MP Metal Path Wmax Distance From Wo To S.U. At Maximum Response RBR Remaining Back Reflection W1 Distance From Wo At Of Max (Forward)L Distance From Datum W2 Distance From Wo At Of Max (Forward)Comments: FC 08-01, 08-04 Root Geometry previously recorded.K .---------- DATIM lit Lo 1-knx Indication % W Forward Backward Li L L2 RBR Remarks Angle No. Of Max Of Max Of Max Of Max Of Amp.DAC W I MP WV MP W2 MP Max Max 45 1 100 .60' .80" N/A N/A N/A N/A N/A N/A N/A N/A Geometry-Root seen 360'60 2 100 1.0" 1.1' N/A N/A N/A N/A N/A NIA NIA N/A Geometry -Root seen 360'Examiner Level li-N Signature Date ReviewerIh Signature Dt Howard, Dean M. 7) ' ~ {11/4/2008}/' -6 Examiner Level ti-N SinareDt1SieRvw Signature Date Hatchett, Jay M. 11/4/2008 N/A Othaminer Level N Signature Date ANSi Review V , Siature Date N/A e.'11/4/2008' N, A Othe : ' ...... ..~gaare .... ,atro i!k/sl/ DUKE ENERGY COMPANY ISI LIMITATION REPORT Summary #: 02.C5.2 L0027 Component ID 2-51A-28-15 remarks:[ NO SCAN SURFACE BEAM DIRECTION No scan on surface #1 LIMITED SCAN L" 1 [ 2 LI 1 L- 2 M Cw ccW due to flange configuration. FROM L N/A to L N/A INCHES FROM WO CL to Beyond See attached sketch. J ANGLE: D 0 0 45 N 60 other FROM 0 DEG to 360 DEGI LI NO SCAN "SURFACE. BEAM DIRECTION LILIMITED SCAN E' 1 -21 [- 2 -cw ccw FROM L to L INCHES FROM WO to _ANGLE: D 0I 45 EL 60 other FROM DEG to DEG LI NO SCAN SURFACE BEAM DIRECTION T LI LIMITED SCAN El 1 [' 2 :M 1 D 2 -cw- ccw FROM L to L INCHES FROM WO to _ANGLE: El 0 45 LI 60 other FROM DEG to DEG LI NO SCAN SURFACE BEAM DIRECTION LILIMITED SCAN E" LI1 ] 2 E I 2 L0 cw -ccw 4 FROM L to L INCHES FROM WO to Sketch(s) attached ANGLE: D 0LI 45 LI 60 other FROM DEG to _ DEG LI yes LI No Prepared By: Dean Hp ard Leve:042 Sheet 3 of 6 RevieWed By: Date: ( Authorized Inspector Date: ,V v* Zhuke Supplemental Report AT TACHMENT A PASE &(o Of gl Report No.: UT-08-127 Page: 4 of 6 Summary No.: 02.C5.21.0027 Examiner: Howard, DeanM.Examiner: Hatchett,JayM. Other: NIA Level: II-N Level: I1-N Level: N/A Reviewer: A Site Review: NIA ANtI Review: .. .. , Date: Date ýZZ~S Comments: Indication

  1. 1 & #2 -360' geometric reflectors due to root.Sketch or Photo: Z:\UT'.PJDEAL\ProfileLine2.jpg FL .,LJ ..FLAA1&e Summary No.: 02.C5.21.0027 Examiner:

Howard, Dean M. " .4 '.d/L v Examiner: Hatchett, Jay M.Other N/A Supplemental Report Report No.: Page: NA 42 A PA6E 67 OF 91 UT-08-127 5 of 6 Date: .- is- Date: Date: Level: I-N Level: II-N Level: N/A Reviewer: Site Review: ANtI Review: Comments: __ _ __ _ _ I~i~ e. c AZ EIF ~4~.2- 17 .22- (1 Cio)~s Sketch oir Photo: 2:\kLiTkIDDEAL\ProtileLin,2,lpg , r-. D' ý, AY %, .21-(%,1 A0 42 ;,CZi /~2 1/J 0 6~uw.21 .'4(5P-!~tU Determination of Percent Coverage for UT Examinations -Pipe Site/Unit: Oconee / 2 Summary No.: 02.C5.21.0027 Workscope: ISI Procedure: Procedure Rev.: Work Order No,: PDI-UT-2 C 01795251 Outage No.: 02-23 Report No.: UT-08-127 Page: 6 of 6 W k:F ME4 45 deg Scan 1 Scan 2 Scan 3 Scan 4 100.000 % Length X 100.000 % Length X 100.000 % Length X 100.000 % Length X 50.000 % volume of length / 100 =0.000 % volume of length / 100 =50.000 % volume of length / 100 =50.000 % volume of length / 100 =50.000 % total for Scan 1 0.000 % total for Scan 2 50.000 % total for Scan 3 50.000 % total lor Scan 4 Add totals and divide by # scans = 37.500 % total for 45 deg Other deq -_ (to be used for supplemental scans)The data to be listed below is for coverage that was not obtained with the 45 deg scans.Scan 1 Scan 2 Scan 3 Scan 4% Length X% Length X% Length X% Length X% volume of length / 100 =..% volume of length / 100 =% volume of length / 100 =% volume of length / 100 =% total for Scan 1% total for Scan 2% total for Scan 3% total for Scan 4 Percent complete coverage Add totals for each scan required and divide by # of scans to determine; 37.500 % Total for complete exam Site Field Supervisor: Site Field Supervisor: Date Date: / /I/z 2ý/o _g AT 1ACHMENT A P AS6E Inq 0F E'/Site/Unit: Oconee 2 Summary No.: 02.C5.21.0029. Workscope: iSI UT Pipe Wt 1 d Examination Procedure: Procedure Rev.: Work Order No.: PDI-UT-2 0C95 01795251 Outage No.: 02-23 Report No.: UT-08-129 Page: 1. of 4 Code: 1998 Cat./Item: C-F-1/C5.21 Location: Drawing No.: 2-51A-28 (1)

Description:

Pipe to Valve 2HP-135 System ID: 51 A Component ID: 2-51A-28-21 Size/Length: N/A Thickness/Diameter: 0.53 /4.0 SS Limitations: Yes -See Attached Limitation Report Start Time: :0940 Finish Time: 1030 Examination Surface: Inside D Outside Surface Condition: GROUND FLUSH Lo Location: 9.1.1.1 Wo Location: Centerline of Weld Couplant: ULTRAGEIL II Batch No.: 07125 Temp. Tool Mfg.: Lutron Serial No.: MCNDE32795 Surface Temp.: 78 -F Cal. Report No.: .CAL-08-125, CAL-08-126 Angle Used i0 45 45T 60 Scanning dB 30 30 44 Indication(s): Yes E3 No F Scan Coverage: Upstream [ Downstream f CW E] CCW []Comments: FC 08-01, 08-04 Results: Accept H Reject R Into __Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes Examiner Level Il-N Signature Date Revie Signature Da Howard, Dean M. 11/4/2008 Examiner Level M i-N .,S alure Date Site Rvw SigatureD Hatchett, Jay M. 11(.X.~~ 14(2 008 N/A Other Level N/A Signature Date ANiI F~view Dategr~N/A 11/4/2008 $-&L4t/.J, 'i/1 c ~t'), L..J AIIACHMENI'H/ PA6E 70 OF 'DUKE ENERGY COMPANY ISI LIMITATION REPORT Summary #: 02.C5.21.0029 Component ID 2-51A-28-21 remarks:[ NO SCAN SURFACE BEAM DIRECTION No scan on surface #2 Li LIMITED SCAN ED 1 F-" 2 [1 [1 2 Z cw 0 ccw. due to valve configuration. FROM L N/A to L N/A INCHES FROM WO Toe to Beyond See attached sketch.ANGLE: 010 D2 45 [] 60 other FROM o DEG to 360 DEG"- NO SCAN SURFACE BEAM DIRECTION .__ _ _ _-LIMITED SCAN f-I. 2 E- 1 [ 2 [:1 cw i cw FROM L to L INCHES FROM WO to ANGLE: Li 0 Ml 45 El 60 other FROM DEG to _ DEG Li NO SCAN SURFACE BEAM DIRECTION DLIMITED SCAN 1 E1- 22 L] 1 i2[] cw -ccw FROM L to L INCHES FROM WO to _ANGLE: Li 0 Li 45 EL 60 other FROM DEG to DEG Li NO SCAN EL LIMITED SCAN SURFACE BEAM DIRECTION[1 1 li2 F1 1 02 0 cw Ficcw I. -I FROM L to L INCHES FROM WO to ANGLE: Li 0 Li 45 Li 60 other FROM DEG to DEG Sketch(s) attached Li yes LI No V" Summary No.: 02.C5.21.0029 Supplem.ntal Report ATTACHMENT /PASE-71/ OF ?)Report No.: '-08-129 Page: 3 of 4 Examiner: Howard, Dean M. -z _Examiner: Hatchett, Jay M. W ,_,'<e //.i'..6 L t ....Level: Il-N Level: II-N Level: N/A S: te R ev ievv' 1,'i 2 AýNJ ei e Ca:e _____________ Fe t4z+/-*( f Other: N/A (-)Comments: AV..D -k.V1/2sici~

  • ~~g~S~z SI- E6(D>VJA'6s*75\

':Z2~ .1\M ,'4 (10) OO>0 O3 6\2-AK -00 W___, _)S o Sketch or Photo: Z:\UnIDDEAL\ProfiteUne2,jpg j FLow VALVE ZýP t~s-S P ýAc r-ii 0M. Deteri Site/Unit: Oconee / 2Summary No.: 02.C5.21.0029 , Workscope: ISt mination of Percent Coverage for UT Examinations -Pipe Procedure: Procedure Rev.: Work Order No.: PDI-UT-2 C 01795251 Outage No.:. 02-23 Report No,: UT,08-129 Page: 4 of 4 45 deo Scan 1 Scan 2 Scan 3 Scan 4% Length X% Length X 100.000 % Length X 100.000 % Length X.50.000 50.000% volume of length / 100 =% volume of length /100 =% volume of length / 100 =% volume of length / 100 =50.000 50.000% total for Scan I% total for Scan 2% total for Scan 3% total for Scan 4 Add totals and divide by # scans = 50.000 % total for 45 dog Other deg -60 (to be used for supplemental scans)The data to be listed below is for coverage that was not obtained with the 45 deg scans.Scan 1 Scan 2 Scan 3 Scan 4 100.000 % Length X 100.000 100.000 % Length X 100.000% Length X% LengthX% volume of length / 100 =% volume of length 1100 =% volume of length / 100 =% volume of length / 100 =100.000 % total for Scan I 100,000 % total for Scan 2% total for Scan 3% total for Scan 4 Percent complete coverage Add totals for each scan required and divide by # of scans to determine; 75.000 % Total for complete exam Site Field Supervisor: 9;;-Site Field Supervisor: Date: LLA~AI Date: / 4 d' 6s-AMTACHME.f A 1 Duke UT Pipe WV .,d Examination PAGE 73 OF ?I 9hOW j Site/Unit: Oconee / 2 Summary No.: 02.CS.21.0031 Workscope: ISI Procedure: Procedure Rev.: Work Order No.: PDI-UT-2 C 01796690 Outage No.: 02-23 Report No.: UT-08-088 Page: 1 of 3 Code: 1998 Cat./item: C-F-1/C5.21 Location: Drawing No.: 2HP-222

Description:

Valve 2HP-26 to Elbow System ID: 51A Component ID: 2HP-222-2 Size/Length: N/A Thickness/Diameter: 0.674 I 4.000 Limitations: Yes -See Attached Limitation Report Start Time: 1040 Finish Time: 1050 Examination Surface: Inside [- Outside F.] Surface Condition: GROUND Lo Location: 9.1.1.1 Wo Location: Weld Centerline Couplant: ULTRAGEL II Batch No.: 07125 Temp. Tool Mfg.: FISHER Serial No.: MCNDE 27219 Surface Temp.: 107 'F Cal. Report No.: CAL0,8-096, CAL-08-097, CAL-08-098. CAL-08-114 Angle Used df 45 1 45T 60 60L, 42T Scanning dB 35.4 47.9 66.7 35.1 Indication(s): Yes [ No & Scan Coverage: Upstream E Downstream ] CW CCW D Comments:-Original inspection performed on 7/29/08 for 45' Ax/Circ, 42'T, and 600 Axial. Ref. Cal Sheets, CAL-08-096, 097 and 098.60°L performed on 11/3/08 to correct transducer size used on previous inspection-Results: Accept L-[ Reject F.. Info F]Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes AIIACHMENI AF 1)A~ 79 aF F1 I DUKE ENERGY COMPANY J _ISI LIMITATION REPORT __Summary #: 02.C5.21.0031 Component ID 2HP-222-2 remarks: f NO SCAN SURFACE BEAM DIRECTION No scan due to Cast r-] LIMITED SCAN LI 1 N 2 Z 1 D- 2 Z cw N ccw Valve configuration. FROM L N/A to L N/A INCHES FROM WO N/A to N/A ANGLE: El 0 [] 45 Z 60 other 60L FROM o DEG to 360 DEG-I NO SCAN SURFACE BEAM DIRECTION-' LIMITED SCAN E- 1 [I 2 D 1 E] 2 -- cw ' ccw FROM L to L INCHES FROM WO to _ _ANGLE: LI 0 E 45 Li 60 other FROM _ DEG to DEG LI NO SCAN SURFACE BEAM DIRECTION _LI LIMITED SCAN L]1 L 2 El 1 L 2 L cw L ccw 1 FROM L ,_ .to L INCHES FROM WO to i ANGLE: [] 0 LI 45 LI 60 other FROM DEG to DEG FL NO SCAN LI LIMITED SCAN SURFACE El I1-I2 BEAM DIRECTION El 1 LI 2 [L cw LI ccw FROM L to L INCHES FROM WO ,to Sketch(s) attached[1L0 FI 45 [-]60 o[ yes LI No -ItemNo. 02.C5.21.0031 6I(I,.WANtve 60W Shear'SI Coverage Claimed = 50%Weld No. 2IP-222-2'alve S2 Scale: 1"=Material)No Coverage Claimed Supplerrental coverage with 60' RL Wave Only See Note: ,, Note: 60' RL scan not included in percentage coverage due to requirements of IOCFR50.55a(b)(2)(xv)(A)(1). Best effort scan with 600 RL obtained 50% coverage in one axial direction. % Coverage Calculations S =Elbow = 50%S2 =Valve = 0%S3 = CW = 50%S4 = CCW 50%(100% of the length x 50% of the volume)(0% of the length x 0% of the volume)(100% of the length x 50% of the volume)(100% of the length x 50% of the volume)Total= 150 / 4 = 37.5 % Aggregate Coverage Inspector / Date: Page 3 of ý ATTACHMENT MAE -,7k,9F ?'I Site/Unit: Oconee /Summary No.: 02.4 Workscope: UT Pipe Wela Examination 2 C5.21.0055 Procedure: Procedure Rev.: Work Order No.: NDE-600 17 01796692 Outage No.: 02-23 Report No.: UT-08-087 Page: 1 of 4 Is[Code: 1998 Cat./Item: C-F-1/C5.21 Location: Drawing No.: 2-51A-17 (2)

Description:

Tee to Pipe System ID: 51A Component ID: 2-51A-17-93 Size/Length: N/A Thickness/Diameter: 0.375/ 2.500 Limitations: Yes -See Attached Limitation Report: Start Time: 0955 Finish Time: 1003 Examination Surface: Inside Outside v Surface Condition: GROUND Lo Location: 9.1.1.3 Wo Location: Weld Centerline Couplant: ULTRAGEL It Batch No.: 07125 Temp. Tool Mfg.: FISHER Serial No.: MCNDE 27219 Surface Temp.: 107 -F Cal. Report No.: CAL-08-093, CAL-08-094, CAL-08-095 Angle Used 0 45 45T 60 70 Scanning dB 45 50 52'.Indication(s): Yes No n/, Scan Coverage: Upstream v Downstream v CW V CCW ;V Comments: Results: Accept Reject v Info Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes Examiner Level I,.N ,"ig"nature, Date Review r. Signature Date Leeper, Winfred C. 7/22/2008 r Examiner Level N/A "ignature Date Site eview Date N/A 7/22/2008 N/A Other Level N/A Signature Date ANIJ ýeiew Date LN/A 7/22/2008 C. /<LCU4L(&-'i- // r Item No. 02.C5.21.0055W Weld No.2-51A-17-93 I'-t U ~-th I 70' Shear Wave Tee S2 Scale: "= 1" I I Coverage Claimed = 50%No Coverage Claimed Supplemental coverage with 700 Shear Wave Only. See Note: Note: 700 Shear Wave scan not included in percentage coverage due to requirements of IOCFR50.55a(b)(2)(xv)(A)(1). Best effort scan with 70' Shear obtained 50% coverage in one axial direction. Side View -Not to Scale-Limited Area Weld No. 2=5 IA- 17-93 Limited 2" in throat area each side of Tee for a total of 4" on Surface 2. Limited area from Lo.+ 1.3" to Lo + 3.3" and from Lo + 5.8" to L + 7.8".Inspector / Date: ___ __Ix ,1z3___ o8 Page z of__ DoJC=Z1/2% Coveracie Calculations Item No. : 02.C5.21.0055 Weld No. : 2-51A-17-93 Pipe 0 = 2.5" = 0.375" Weld Length =9.11" Limited scan on Surface 2 due to the throat of the tee for 4" of the weld length Limited scan on Surface 1 due to adjacent pipe for 2" of the weld length% of Length at throat of Tee = 4 / 9.1 x 100 = 44.0%.% of Length examined 100% = 100 -44.0 = 56.0%.S1 = Pi S1 = P!Tc S2 = Ti S2= Ti Ti S3 =S4 =Aggregate Coverage Calculation pe 56 % (56.0% of the Length x 100% of the Volume)pe 22 % (44.0% of the Length x 50% of the Volume)oaM S1 78.0 %ee 56 % ( 56.0% of the Length x 100% of the Volume)ee 0 % ( 44.0% of the Length x 0% of the Volume)otal S2 56.0 %100 % ( 100% of the Length x 100% of the Volume )100 % ( 100% of the Length x 100% of the Volume )Total = 334.0 4 =83.5% Aggregate Coverage Inspector / Date: s o't Page J? of_! <Ci-L[MrrED EXAMINATION COVERAGE CRECKLUST[SI Summacy No: O C5. C:.Zi. OQ @Bý (UT) Verify search unit wedge index to nose dimension; [3" (UT) Draw the examination volume showing beam paths.(ALL) Draw the examination volume or area with obstructions including dimensions on the Supplemental Report, or if the drawing is too large, attach it to the Supplemental Report; (Marked-up drawings and/or digital photos are acceptable if dimensioned), [ (ALL) Note the scale of the drawing;(ALL) Calculate coverage in a detailed and orderly method;Note: Does not apply to hangers, snubbers, restraints or supports ii (ALL) Complete IDDEAL forms: "Limitation Work Sheet" and "Supplemental Report".EI' (ALL) Check the "Reject" box on the examination data sheet.[WS NDE Level III? Date " 3 MMP NDE Level 11 Date 7 Z ...Figure 13 Limited Examination Coverage Checklist VERIFY HARD COPY WITH NEDI. VERSION IMMEDIATELY PRIOR TO INITIAL USE AND EVERY 14 DAYS THEREAFTER WHILE THE PROCEDURE IS IN USE q A17AC~H~tiA t Duke UT Pipe Wt .d Examination PA6E YD OF Ei Site/Unit: Oconee / 2 Procedure: NDE-600 Outage No.:. 02-23 Summary No.: 02.C5.21.0256 Procedure Rev.: 17 Report No.: UT-08-086 Workscope: ISI Work Order No.: 01796700 Page: 1 of 2 Code: 1998/2000A Cat./Item:,. C-F-1/C5.21 Location: Drawing No.: 2HP-221

Description:

Valve 2HP-410 to Elbow System ID: 51A Component ID: 2HP-221-22 Size/Length: N/A Thickness/Diameter: 0.531 /4.000 Limitations: Yes -See Attached Limitation Report Start Time: 1029 Finish Time: 1039 Examination Surface: Inside _j Outside F, Surface Condition: AS GROUND Lo Location: 9.1.1.1 Wo Location: WELD CENTERLINE Couplant: ULTRAGEL II Batch No,; 07125 Temp. Tool Mfg.: FISHER Serial No.: MCNDE 27219 Surface Temp.: 88 ýF Cal. Report No.: CAL-08-090, CAL-08-091, CAL-08'092 Angle Used 0 45 45Tj 60 601L Scanning dB 45 50 52 Indication(s): Yes .No .] Scan Coverage: Upstream -I Downstream ,1' CW CCW Comments: Results: Accept f-l Reject InfO o)Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes Examiner Level II-N Sign Date Reviewe(I Signature Date Leeper, Winfred C. ,7/292008 R0 7 ,-:1 Examiner Level N/A " Signature 7- Date Site Review Signature Date N/A 7/29/2008 N/A Other Level N/A Sicnature Date. ANII tReview , .,j (, 'iar nature Date N/A 7/29/2008 /\. L-ký C q'; J & ý / L3/4/ Item No. 02.C5.21.0256 600 RLWave Weld No. 2BP-221-22

1 Scale: 1= I" rial)No Coverage Claimed Supplemental coverage with 600 RL Wave Only See Note: Coverage Claimed = 50%Note: 600 RL scan not included in percentage coverage due to requirements of 10CFR50.55a(b)(2)(xv)(A)(1).

Best effort scan with 600 RL obtained 50% coverage in one axial direction. % Coverage Calculations S1 =Elbow S2 = Valve 50%0%(100% of the length x 50% of the volume)(0% of the length x 0% of the volume)(100% of the length x 50% of the volume)(100% of the length x 50% of the volume)S3 = CW = 50%S4 = CCW Total 50%= 150 / 4 = 37.5 % Aggregate Coverage I-M., / a-e:lo5_ Page a, of Lnspector / Date : AIIACHMENT 13 PA6E, / r OF6 Site/Unit: Oconee / 3 Summary No.: 03.B3.110.0006 Workscope: is[UT Vessel Examination Procedure: Procedure Rev.: Work Order No.: NDE-640 5 813802 Outage No.: 03-24 Report No.: UT-09-210 Page: 1 of Code: 1998 Cat./item: B-D 1B3.110 Location: Drawing No.: ISI-OCN3-002

== Description:==

Nozzle to Shell System ID: 50 Component ID: 3-PZR-WP26-4 Size/Length: N/A Thickness/Diameter: 6.18715.750/CS Limitations: See report # UT-09-213 for limitations calculations Start Time: 1000 Finish Time: 1040 Examination Surface: Inside E] Outside n.1 Surface Condition: GROUND SMOOTH Lo Location: 9.2.3 Wo Location: Centerline of Weld Couplant: ULTRAGEL II Batch No.: 07225 Temp. Tool Mfg.: D.A.S Serial No.: MCNDE32825 Surface Temp.: 82 -F Cal. Report No.: CAL-09-255 Angle Used 1 0 45 45T 6 60 PT JOT Scanning dB 35.5 Indication(s): Yes Ii No f] Scan Coverage: Upstream RI Downstream R] CW El CCW El Comments: None Results: Accept E] Reject W Info E _Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes Examiner Level II-N P..... Date Reviewer, Signature Date.T u c k e r, D a v id K .5ig n at ue20 0 9 X Examiner Level Il-N _. __e ture Date Site .Review Signature Date Dean, Steven 51,412009 _ _ _............ Other Level N/A Signature Date. ANIIReview 'Dae I N/A 7S .c/L '(~44 WA11 MUEW 6 PAGE 2 OF ý I Site/Unit: Summary No.: Workscope: UT Vessel Examination Oconee / 3 03.B3.1110.0006 iSI Procedure: Procedure Rev.: Work Order No.: NIDE-820 4 Outage No.: 03-24 Report No.: UT-09-213 Page: 1 of 8 813802 Code: 1998 Cat./Item: B-D /B3.110 Location: Drawing No.: ISI-OCN3-002

== Description:==

Nozzle to Shell System ID: 50 Component ID: 3-PZR-WP26-4 Size/Length: Thickness/Diameter: 6.18715.750/CS Limitations: Due to nozzle configuration -See supplemental reports Start Time: 1000 Finish Time: 1056 Examination Surface: Inside D1 Outside [] Surface Condition: GROUND SMOOTH Lo Location: 9.2.3 Wo Location: Centerline of Weld Couplant: ULTRAGEL II Batch No.: 07225 Temp. Tool Mfg.: D.A.S Serial No.: MCNDE32825 Surface Temp.: 82 "F Cal. Report No.: CAL409-256 thrutCAL-09-259 Angle Used 0 451 45T 60 60T 60RL Scanning dB 57.6 57.6 73.5 72.2 Indication(s): Yes D No [ Scan Coverage: Upstream [] Downstream [] CW [ CCW 21 Comments: 35° -57.8dB; 35T* -57.8 dB Additional Examiner -Q L [1 5/4/2009 Results: Accept E] Reject W] Info E_Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes Examiner Level II-N signS , Date Review I.er Signature Date Tucker, David K. 514/2009 5"- jg.,aj Examiner Level II-N .re Date ieR Signature Dean, Steven .5/4/2009 _Other Level Il-N Signature Date ANII Review 4gat Date]Hollis, Jacob 54/42009 Z5~at /4/L.4Vd A11ACHMEH E PAGE 2 QF,/DUKE POWER COMPANY ISI LIMITATION REPORT ComponentlWeld ID: 3PZR-WP26-4 Item No: 03.B3.110.0006 remarks:[ NO SCAN SURFACE BEAM DIRECTION 35 & 6ORL angles LIMITED SCAN Z 1 0 2 0 1 9 2 0 cw 0 ccw Nozzle configuration CLto FROM L N/A to L N/A INCHES FROM WO -1" to Beyond ANGLE: Z 0 [ 45 [D 60 other

  • FROM o DEG to 360 DEG L] NO SCAN SURFACE BEAM DIRECTION L-] LIMITED SCAN [-I 1l 2 -i L[] 2 0 cw EL ccw FROM L to L INCHES FROM WO to ANGLE: El 0 [] 45 El 60 other FROM. DEG to DEG Li NO SCAN SURFACE BEAM DIRECTION-LIMITED SCAN I- ] 22 1- L]2E)cw L ccw FROM L to L INCHES FROM WO to ......ANGLE: E] 0 El 45 E] 60 other FROM _ DEG to .... DEG El NO SCAN SURFACE BEAM DIRECTION-LIMITED SCAN I- Li 2 ] I R 2 ]cw i ccw FROM L to L INCHES FROM WO to Sketch(s) attached ANGLE: Li 0 [] 45 E] 60 other FROM DEG to DEG yes i No Prepared By: David Tucker 1-- Date: 05/04/20 09 Sheet - of -8.Reviewed By: Date:tA ..te DateP...

ýALC: PZR Sampling Nozzle to Shell % of Coverage Item No.: 03.B3.110.0006 Weld No. :.WP26-4 Weld Coverane Scan Si S2 Cw CCW Angle 350,450 & 600 350,450 & 600 350 & 450 350 & 450 Total% Coverage Obtained 61.46 0 0 0 61.46 61.46 +4=15.4% Coverage Base Material Coverage S1 Cw & CCw 350,450 & 600 450&3 50 Total 67.2 42.4 109.6 54.8 33.9 109.6 2=% Coverage% Coverage 60OScan Coverage Aggregate Coverage = Weld + Base Material + 00 -3 34.7% Coverage Inspector / Date : t DPo Page _L of _6 AT IACHMEHI *PAGE_5 OF Item No. : 03.B3.110.0006 Pressuflz Weld No.: WP26-4 Inspector/Date

David Tucker 0514109,40/'Z STotal Base Metal Examined with at lea Sampling Nozzle to Shell st 2 angles from one direction.

A combination of 350,45', and 60' angles were used to obtain coverage.% Examined = (24.45 + 5.705) / 44.87 x 100 = 67.2%.350 600 450 24.45 sq. in.Shell Stwface 1\ N N \ N \ N N N N N N N NN \N N\ N \ N N N N N N N NN N N N N N NNN\\\ N 5.705 sq. in. --14 og MAE 6 OF J, Item No.: 03.B3.110.0006 Pressurizer Sampling Nozzle to Shell Weld No.: WP26-4 Inspector/Date

David Tucker 05/04/09 Noz Total Weld Metal Examined with at least 2 angles from one direction.

Surfac A combination of 350,450, and 600 angles were used to obtain coverage.% Examined from Surface 1 = 7.015 / 11.413 x 100 = 61.46%.% Examined from Surface 2, CW, and CCW = 0%.350..Shell Surface 1 7.015 sq. in. , le e 2 5 "Pp AI1ACHMENi PA6E 7 OF , Item No.: 03.B33.110.0006 Weld No.: WP26-4 Pressurizer Sampling Nozzle to Shell Inspector/Date: David Thcker 05/04/09]Base Metal Examined with 35 0 and 45 0 angles.% Examined 35 0 and 450 = 19.03 / 44.87 x 100 = 42.4%.35'and 45 0 Circ. scan 19.03 sq. in.Shell Surface 1 f ATTACHMER1 1 MAE 9 OF /Item No. : 03.B3.110.0006 Weld No.: WP26-4 Pressurizer Sampling Nozzle to Shell Inspector/Date

David lucker 05/04/09 Nozzle Surface 2 I'm" Base and Weld Metal Examined with 00 angle.% Examined 0' = 19.03 / 56.16 x 100 = 33.9%.0 0 .19.03 sq. in.Shell Surface I 7 or AIIACHMENTL-PAGE 9 OF 1 Item No.: 03.B3.110.0006 Presslri-Weld No.: WP26-4 Inspector/Date
David Tucker 5/4/09 zý01-Sampling Nozzle to Shell Nozzle Surface 2 LIII 600 60° RL Shell Surface I A I IA CMENfl 2)PA6E ID aF / " Site/Unit:

Oconee I 3 Summary No.: 03.B3.110.0007 Workscope: ISI UT Vessel Examination Procedure: Procedure Rev.: Work Order No.: NDE-640 5 813802 Outage No.: 03-24 Report No.: UT.09-211 Page: 1 of I Code: 1998 Cat./tem: B-D /83.110 Location: Drawing No.: ISI-OCN3-002

== Description:==

Nozzle to Shell System ID: 50 Component ID: 3-PZR-WP26-5 Size/Length: Thickness/Diameter: 6.18715.7501CS Limitations: See report # UT-09-214 for limitations calculations Start Time: 1043 Finish Time: 1103 Examination Surface: Inside LI Outside j] Surface Condition: GROUND SMOOTH Lo Location: 9.2.3 Wo Location: Centerline of Weld Couplant: ULTRAGEL II Batch No.: 07225 Temp. Tool Mfg.: D.A-S Serial No.: MCNDE32825 Surface Temp.: 82 °F Cal. Report No.: CAL-09-255 Angle Used 10 45 45T 60 60T Scanning dB 35.5 Indication(s): Yes 1J No [] Scan Coverage: Upstream [ Downstream [] CW 0 CCW LI Comments: None Results: Accept [ Reject W Info __Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes Examiner Level 11-N Si e Date Review6e Signaturei Oaw Tucker, David K. 5/4/2009 Examiner Level II-N Date SiteRview, Signature Date Dean, Steven 5/4/2009 Other Level N/A Signature Date ANII Review ' Date N/A 14C 06 i 5 C910Z ATTACHMENT PASE it OF Site/Unit: Oconee /Summary No.: 03.B Workscope: UT Vessel Examination 3 3.110.0007 ISI Procedure: Procedure Rev.: Work Order No.: NDE-820 4 813802 Outage No.: 03-24 Report No.: UT-09-214 Page: 1 of 8 Code: 1998 Cat./ltem: B-D 183.110 Location: Drawing No.: ISI-OCN3-002

== Description:==

Nozzle to Shell System ID: 50 Component ID: 3-PZR-WP26-5 Size/Length: Thickness/Diameter: 6.18715.750/CS Limitations: Due to nozzle configuration -See supplemental reports Start Time: 1016 Finish Time: 1056 Examination Surface: Inside [] Outside n- Surface Condition: GROUND SMOOTH Lo Location: 9.2.3 Wo Location: Centerline of Weld Couplant: ULTRAGEL, II Batch No.: 07225 Temp. Tool Mfg.: D.A.S Serial No.: MCNDE32825 Surface Temp.: 82 -F Cal. Report No.: CAL-09-256 thru CAL-09-259 Angle Used 0 45 45T 60 60T j 6ORL Scanning dB 57.6 57.6 73.5 72.2 Indication(s): Yes fj No [] Scan Coverage: Upstream [] Downstream [] CW 91 CCW 21 Comments: 350 -57.8dB, 35T° -57.8dB Additional Examiner: John C. Day, Lpmql II, 0510412009 Results: Accept El Reject [] Infio __Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes Examiner Level 11.N _ Date Reviewer Signature Date Tucker, David K.. 514/20.09 ew __ ____ .,__-_/_,- _Examiner Level II-N Si at e Date Site Review Da ( Signature Date Dean, Steven 5/412009 Other Level ..N S ... Date ANI, Review t Date Hollis, Jacob pg "5/412009 5710 41// Al 1ACHMAENT P A 6E /2- 0 F DUKE POWER COMPANY ISI LIMITATION REPORT Component/Weld ID: 3PZR-WP26-5 Item No: 03.13.110.0007 remarks:[ NO SCAN SURFACE BEAM DIRECTION

  • 35 & 6ORL angles[i LIMITED SCAN 1I 1 2 [1 [M 2 [ cw ccw Nozle configuration CLto FROM L N/A to L N/A INCHES FROMWO -1" to Beyond ANGLE: [ 0 [9 45 N 60 other
  • FROM a DEG to 360 DEG[] NO SCAN SURFACE BEAM DIRECTION L-' LIMITED SCAN E]'I [1 2 i 1 [] 2 [] cw ]ccw FROM L to L INCHES FROM WO to ANGLE: [] 0 El 45 n] 60 other FROM DEG to DEG L] NO SCAN SURFACE BEAM DIRECTION LI LIMITED SCAN LI L] 2 1 [L] 2 El cw D ccw FROM L to L INCHES FROM WO to ANGLE: E] 0 L] 45 E] 60 other FROM DEG to DEG LI NO SCAN LI LIMITED SCAN SURFACE BEAM DIRECTION LII [-I 2 ll [ -2 L cw i-ccw FROM L ANGLE: to L EIi 0 EI 45 INCHES FROM WO t r-1 690 other FROM .DEG to 0 DEG Sketch(s) attached yes El No Prepared By: David Tucker%, .05/04/2009 1 Sheet -,2. of Insl Date: V

<V L~J:2z~PZR Sampling Nozzle to Shell % of Coverage Item No. : 03.B3.110.0007 Weld No. : WP26-5 Weld Coverage Scan S1-$S2 Cw CCw An3le 350,450 & 60-350450 & 600 350 & 450 350 & 450 Total% Coverage Obtained 61.46 0 0 0 61.46 15.4 61.46 .-4=% Coverage Base Material Coverage S1 cw&CCw 350,450 & 600 45T&3o5t Total 67.2 42.4 109.6 54.8 33.9 109.6 + 2 =% Coverage% Coverage 00 Scan Coverage Aggregate Coverage = Weld + Base Material + 00 -3 34.7% Goverap-e Inspector / Date : t P oJ Page 3 of g A11 ACHMENT PA E Iq Of Item No. : 03.B3.110.0007 Pressurize Weld No.: WP26-5 Inspector/Date: David Tucker 05/04/09 /,-r Sampling Nozzle to Shell E 1 Base Metal Examined with 350 and 450 angles.% Examined 35 0 and 45' = 19.03 / 44.87 x 100 = 42.4%.35°and 45 0 Circ. scan -I 19.03 sq. in.Shell Surface 1***\\\\\ \ Item No.: 03.B3.110.0007 Pressurizer Sampling Nozzle to Shell MA6E [5 LFo Weld No.: WP26-5 Inspector/Date: David Tucker 05/04/09 Nozzle Total Weld Metal Examined with at least 2 angles from one direction. Surface 2 A combination of 350,450, and 600 angles were used to obtain coverage.% Examined from Surface 1 = 7.015 / 11.413 x 100 =61.46%.% Examined from Surface 2, CW, and CCW = 0%.5350 0600 459-Shell Surface 1 S ~~~~ N\ 777=7.015 sq. in. Al1ACHMENT 1 PAGE /, OF 6/Item No. : 03.B3.110.0007 Pressurizer Sampling Nozzle to Shell Weld No.: WP26-5 David Tucker 5/4/09 Inspector/Date: Nozzle Surface 2 Li 600 600 RL Shell Surface 1 W1ACHMENT PASE /'7 Of ~Item No.: 03.B3.110.0007 PressukAu Weld No.: WP26-5 Inspector/Date: David Tucker 05/04/09.- -Sampling Nozzle to Shell ý] Base and Weld Metal Examined with 00 angle.% Examined 0' = 19.03 / 56.16x 100 =33.9%.1:9.03 sq. in.Shell Surface I 7 oP8 AIIACHMENT g PAGE /I OF (,I Item No.: 03.B3.110.0007 Pressuriz, Weld No. : WP26-5 Inspector/Date: David Tucker 05/4/09 Z4 er Sampling Nozzle to Shell WI Total Base Metal Examined with at least 2 angles from one direction. A combination of 35',450, and 600 angles were used to obtain coverage.% Examined = (24.45 + 5.705) / 44.87 x 100 = 67.2%.350 600 450 " 24.45 sq. in.Shell Surface 1~\ N N \ \ N \ NN \N \ N N NN \N N 7 \7NiX7 5.705 sq. in oFr8 Al 1ACHMENT L PAH Eq0 ~F Site/Unit: Oconee I Summary No.: 03.B Workscope: UT Vessel Examination 3 3.110.0008 Procedure: Procedure Rev.: Work Order No.: NDE-640 5 813802 Outage No.: 03-24 Report No.: UT-09-212 Page: 1 of I ISI Code: 1998 Cat./Item: B-D /B3.110 Location: Drawing No.: ISI-OCN3-002 Descriptfon: Nozzle to Shell System ID: 50 Component ID: 3-PZR-WP26-6 Size/Length: Thickness/Diameter: 6.18715.750/CS Limitations: See report # UT-09-215 for limitations calculations Start Time: 11105 Finish Time: 1145 Examination Surface: Inside [] Outside [] Surface Condition: GROUND SMOOTH Lo Location: 9.2.3 Wo Location: Centerline of Weld Couplant: ULTRAGEL II Batch No.: 07225 Temp. Tool Mfg.: D.A.S Serial No.: MCNDE32825 Surface Temp.: 82 °F Cal. Report No.: CAL-09-255 Angle Used 0 45 45T 60 60T " Scanning dB 35.5 Indication(s): Yes FI No 2 Scan Coverage: Upstream RJ Downstream [] CW E) CCW L1 Comments: None Results: Accept LI Reject [] Info M_Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes Examiner Level I-N S. Sin Date Reviewer Signature Date Tucker, David K. 4 , ....... 51412009 ,./-.'*c Examiner Level li-N j Sg',ure Date Site Review Signature Date Dean, Steven 2 5/4/2009 Other Level NIA Signature Date ANII Review ,u Date N/AAca6CC Date A11ACHMENT PAE QI)rc OF Site/Unit: Oconee 1 3 Summary No.: 03.B3.110.0008 Workscope: ISI UT Vessel Examination Procedure: Procedure Rev.: Work Order No.: NDE-820 4 813802 Outage No.: 03-24 Report No.: UT-09-215 Page: 1 of 8 Code: 1998 Cat./item: B-D /B3.110 Location: Drawing No.: ISI-OCN3-002

== Description:==

Nozzle to Shell System ID: 50 Component ID: 3-PZR-WP26-6 Size/Length: _ Thickness/Diameter: 6.18715.750/CS Limitations: Due to nozzle configuration -See supplemental reports Start Time: '1016 Finish Time: 1145 Examination Surface: Inside E) Outside n./ Surface Condition: GROUND SMOOTH Lo Location: 9.2.3 Wo Location: Centerline of Weld Couplan4: ULTRAGEI+/- II Batch No.: 07225 Temp. Tool Mfg.: D.A.S Serial No.: MCNDE32825 Surface Temp.: 82 0 F Cal. Report No.: CAL409-256thru CAL-09-259 Angle Used 0 145 145T 6I60T 60RL Scanning dB 57.6 57.6 73.5 72.2 Indication(s): Yes [J No [ Scan Coverage: Upstream I] Downstream f] CW [] CCW [Comments: 35° -57.8dB, 35T° -57.8dB Additional Examiner: John C. Day, Level II, 0510412009 Results: Accept EJ Reject W Info E_Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes Examiner Level li-N .j______ Date Review 4/) Signature Date Tucker, David K. 514/2009 -/.. 0 Examiner Level II-N S'gnature Date SiteReview Y Signature Date Dean, Steven 5/412009 Other Level iI-N SrntrDate ANII Review 19 3'uata Date Hollis, Jacob 5/,4/2009,.i~$C5 ~tf~t>Ae'6 4-~ AItIACHMENI DUKE POWER COMPANY ISI LIMITATION REPORT ComponentlWeld ID: 3PZR-WP26-6 Item No: 03.B3.110.0008 remarks:{ NO SCAN SURFACE BEAM DIRECTION

  • 35 & 6ORL angles I LIMITED SCAN Z 1 [ 2 0 1 JZ 2 0 cw 0 ccw Nozle configuration CLto FROM L N/A to L N/A INCHES FROM WO -1" to Beyond ANGLE: [ 0 [ 45 [ 60 other
  • FROM 0 DEG to 36o DEG-NO SCAN SURFACE BEAM DIRECTION-LIMITED SCAN I1 1 2 -i 1 -2 I cw Il ccw FROM L to L INCHES FROM WO to ANGLE: E] 0 El 45 [1 60 other FROM DEG to _ DEG I- NO SCAN SURFACE BEAM DIRECTION LIMITED SCAN 'I 1 2 Ei 1 j 2 [] cw F- ccw FROM L to L INCHES FROM WO to ANGLE: F] 0 U 45 U 60 other FROM DEG to DEG L- NO SCAN SURFACE BEAM DIRECTION-LIMITED SCAN l I El 22 1 El 2 -I cw ccw FROM L to L INCHES FROM WO to Sketch(s) attached ANGLE: El 0 EU 45 nl 60 other FROM DEG to DEG Z yes U-"l No Prepared By: David Tucker, ý 1, Date: 05/04/2009 Sheet -.2. of -Reviewed By: Date: -/ -Autho'd t Date:_5 7.

LAh C=%PZR Sampling Nozzle to Shell % of Coverage Item No. : 03.B3.110.0008 Weld No.: WP26-6 Weld Coverage Scan S1 S2 Cw CCw Angle 350,450 & 600 350,450 & 60Q 350 & 450 350 & 450 Total 61.46 +4=% Coverage Obtained 61.46 0 0 0 61.46 15.4% Coverage Base Material Coverage S1 Cw & CCw 350,450 & 600 450&350 Total 67.2 42.4 109.6 54.8 33.9 109.6 + 2 =% Coverage% Coverage 0' Scan Coverage Aggregate Coverage = Weld + Base Material + 00 -3 34.7% Coverage Page _ of e Inspector / Date : 3/0ý Item No.: 03.B3.110.0008 Pessurizer Sampling Nozzle to Shell A Weld No.: WP26-6 Inspector/Date: David Tucker 05/4/09 14W...... Nozzle"-Total Base Metal Examined with at least 2 angles from one direction. SuNface 2 A combination of 35 0 ,45 0 , and 600 angles were used to obtain coverage.% Examined = (24.45 + 5.705) / 44.87 x 100 = 67.2%.35 0 600 450P 24.45 sq. in........................ ..,'%Shell Surface 1 N N N N N N N N \ N N N \ N \ N N N N N N N N N N N N N N N N N N NN N N N ,"\.\ \ \ \\\ N.\ \\\ \ N\ \ \ \ Ný \ "-,\ \ N ,N ,"" \\\ " \ \ N\ , 5.705 sq. in,, A11ACHMEN1 B PAGE,.2 / Of I.Item No. : 03.B3.110.0008 Pressuit Weld No.: WP26-6 Inspector/Date

David Tucker 05/04/09,4?--,er Sampling Nozzle to Shell IW Total Weld Metal Examined with at least 2 angles from one direction.

A combination of 35°,45 0 , and 60' angles were used to obtain coverage.% Examined from Surface I = 7.015 / 11.413 x 100 = 61.46%.% Examined from Surface 2, CW, and CCW = 0%.350 6 045°6 I Shell Surface 1 , \ \ \ -ý, N \ \ \ \ \ N \ \ \ \ N ", \ \ \ \ \ N \ N \ \ -\ \ N \ \ "ý \ N --,-ý \ \ \ \ N N \ \ \ -ý N N \ N I \ X -'-7.015 sq. in. P A ýE?. F Item No. : 03.133.110.0008 Il Weld No.: WP26-6 Inspector/Date: David Tucker 05/04/09-essurizer Sampling Nozzle to Shell Nozzle Surface 2 EZI Base Metal Examined with 350 and 450 angles.% Examined 35°and 45' = 19.03 / 44.87 x 100 = 42.4%.35 0 and 45°Circ. scan 19.03 sq. in.Shell Surface 1 A11ACHMAENT 5'PAGE ?_(o F (6O I Item No.: 03.B3.110.0008 PresSurize] Weld No.: WP26-6 Inspector/Date

David Tucker 05/04/09/>/

--r Sampling Nozzle to Shell] Base and Weld Metal Examined with 00 angle.% Examined 0' = 19.03 / 56.16 x 100 = 33.9%.19.03 sq. in.Shell Surface I+ I I f'7 o r-Relief Request 11 ON 002 The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. Therefore, the available coverage will not meet the acceptance criteria of this Code Case.31.5. Proposed Alternative and Basis for Use This weld was examined using procedures, equipment, and personnel qualified in accordance with ASME Section XI, Appendix VIII. No alternative examinations are planned for the weld during the current inspection interval.Radiography (RT) is not a desired option because RT is limited in the ability to detect service induced flaws. Additionally, radiography has not been qualified through performance demonstration. 31.6. Duration of Proposed Alternative This request is proposed for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.31.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 03.B9.11.0064 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section Xl, 1998 Edition with the 2000 Addenda.In addition to the volumetric examination with limited coverage, Duke performed a surface examination (code required) on this B9.11 item. The result from the surface examination was acceptable. The system leakage test performed each refueling outage in accordance with Table IWB-2500-1; Examination Category B-P requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric, surface, and pressure test), Reactor Building Normal Sump monitoring provides additional assurance that, in the event that leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the acceptable results of the surface examinations, the pressure testing (VT-2) examinations required by Section Xl, and the leakage monitoring, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 63 of 71 Relief Request 11 ON 002 32.0 Weld #3-PDA2-1 32.1. ASME Code Component(s) Affected Unit 3 Reactor Coolant Pump 3A2 Casing Nozzle to Safe-End Weld #3-PDA2-1, Summary Number 03.B9.11.0070 32.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section Xl, 1998 Edition through the 2000 Addenda 32.3. Applicable Code Requirement IWB-2500, Table IWB-2500-1, Examination Category B-J, Item Number B9.11 Figure IWB-2500-8 (c), 100% Volume Coverage of Examination Volume C-D-E-F 32.4. Impracticality of Compliance Component configuration:

  • Surface 1: Stainless Steel Safe-end* Surface 2: Cast Stainless Steel Pump Casing* NPS: 33.50 in.* Thickness:

2.330 in.Scanning requirements are described in 10CFR.50.55a (b)(2)(xv)(A)(1). The aggregate coverage was calculated from the following: 700 shear waves obtained 50% coverage in one axial direction (S1 -safe-end)700 shear waves obtained 0% coverage in one axial direction (S2 -pump casing)* 450 shear waves obtained 50% coverage in one circ. direction (CW).* 450 shear waves obtained 50% coverage in one circ. direction (CCW).* The aggregate coverage was calculated to be (50% + 0% + 50% +50%)/4 = 37.5%.In addition, a best effort examination was performed using 600 and 700 longitudinal waves to the extent possible in the upper 2/3 area of interest.The component limitation was caused by the cast stainless steel pump casing material. In order to scan all of the required volume for this weld, the component would have to be redesigned, which is impractical. Page 64 of 71 Relief Request 11 ON 002 The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. Therefore, the available coverage will not meet the acceptance criteria of this Code Case.32.5. Proposed Alternative and Basis for Use This weld was examined using procedures, equipment, and personnel qualified in accordance with ASME Section Xl, Appendix VIII. No alternative examinations are planned for the weld during the current inspection interval.Radiography (RT) is not a desired option because RT is limited in the ability to detect service induced flaws. Additionally, radiography has not been qualified through performance demonstration. 32.6. Duration of Proposed Alternative This request is proposed for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.32.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 03.B9.11.0070 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section Xl, 1998 Edition with the 2000 Addenda.In addition to the volumetric examination with limited coverage, Duke performed a surface examination (code required) on this B9.11 item. The result from the surface examination was acceptable. The system leakage test performed each refueling outage in accordance with Table IWB-2500-1; Examination Category B-P requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric, surface, and pressure test), Reactor Building Normal Sump monitoring provides additional assurance that, in the event that leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the acceptable results of the surface examinations, the pressure testing (VT-2) examinations required by Section XI, and the leakage monitoring, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 65 of 71 Relief Request 11 ON 002 33.0 Weld #3-PDB1-1 33.1. ASME Code Component(s) Affected Unit 3 Reactor Coolant Pump 3B1 Casing Nozzle to Safe-End Weld #3-PDBI-1, Summary Number 03.B9.11.0072 33.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section XI, 1998 Edition through the 2000 Addenda 33.3. Applicable Code Requirement IWB-2500, Table IWB-2500-1, Examination Category B-J, Item Number B9.11 Figure IWB-2500-8 (c), 100% Volume Coverage of Examination Volume C-D-E-F 33.4. Impracticality of Compliance Component configuration:

  • Surface 1: Pump Casing* Surface 2: Safe-end* NPS: 33.50 in.* Thickness:

2.330 in.Scanning requirements are described in 10CFR.50.55a (b)(2)(xv)(A)(1). The aggregate coverage was calculated from the following: 0 600 shear waves obtained 0% coverage in one axial direction (S1 -pump casing)* 600 shear waves obtained 50% coverage in one axial direction (S2 -safe-end)* 450 shear waves obtained 50% coverage in one circ. direction (CW).0 450 shear waves obtained 50% coverage in one circ. direction (CCW).The aggregate coverage was calculated to be (0% + 50% + 50% +50%)/4 = 37.5%.The component limitation was caused by the cast stainless steel pump casing material. In order to scan all of the required volume for this weld, the component would have to be redesigned, which is impractical. The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. Therefore, the available coverage will not meet the acceptance criteria of this Code Case.Page 66 of 71 Relief Request 11 ON 002 33.5. Proposed Alternative and Basis for Use This weld was examined using procedures, equipment, and personnel qualified in accordance with ASME Section Xl, Appendix VIII. No alternative examinations are planned for the weld during the current inspection interval.Radiography (RT) is not a desired option because RT is limited in the ability to detect service induced flaws. Additionally, radiography has not been qualified through performance demonstration. 33.6. Duration of Proposed Alternative This request is proposed for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.33.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 03.1B9.11.0072 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section Xl, 1998 Edition with the 2000 Addenda.The system leakage test performed each refueling outage in accordance with Table IWB-2500-1; Examination Category B-P requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric and pressure test), Reactor Building Normal Sump monitoring provides additional assurance that, in the event that leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the pressure testing (VT-2) examinations required by Section Xl, and the leakage monitoring, it is Duke's position that the combination of examinations providess a reasonable assurance of quality and safety.Page 67 of 71 Relief Request 11 ON 002 34.0 Weld #3HP-365-40 34.1. ASME Code Component(s) Affected Unit 3 Valve 3HP027 to Elbow Weld #3HP-365-40, Summary Number 03.C5.21.0034 34.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section XI, 1998 Edition through the 2000 Addenda 34.3. Applicable Code Requirement IWC-2500, Table IWC-2500-1, Examination Category C-F-i, Item Number C5.21 Figure IWC-2500-7(a), 100% Volume Coverage of Examination Volume C-D-E-F 34.4. Impracticality of Compliance Component configuration:

  • Surface 1: Elbow/Stainless
  • Surface 2: Valve/Cast Stainless* NPS: 4.0 in.* Thickness:

0.674 in.Scanning requirements are described in 10CFR.50.55a (b)(2)(xv)(A)(1). The aggregate coverage was calculated from the following:

  • 600 shear waves obtained 50% coverage in one axial direction (S1 -elbow)* 600 shear waves obtained 0% coverage in one axial direction (S2 -valve)* 450 shear waves obtained 50% coverage in one circ. direction (CW).* 450 shear waves obtained 50% coverage in one circ. direction (CCW).The aggregate coverage was calculated to be (50% + 0% + 50% +50%)/4 = 37.5%.The limitation of the component was caused by the taper of the valve configuration and cast stainless steel material.

In order to scan all of the required volume for this weld, the component would have to be redesigned, which is impractical. Page 68 of 71 Relief Request 11 ON 002 The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. Therefore, the available coverage will not meet the acceptance criteria of this Code Case.34.5. Proposed Alternative and Basis for Use This weld was examined using procedures, equipment, and personnel qualified in accordance with ASME Section XI, Appendix VIII. No alternative examinations are planned for the weld during the current inspection interval.Radiography (RT) is not a desired option because RT is limited in the ability to detect service induced flaws. Additionally, radiography has not been qualified through performance demonstration. 34.6. Duration of Proposed Alternative This request is proposed for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.34.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 03.C5.21.0034 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section Xl, 1998 Edition with the 2000 Addenda.The system leakage test performed each inspection period in accordance with Table IWC-2500-1; Examination Category C-H requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric and pressure test), visual observations performed during operator rounds provide additional assurance that in the event leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the pressure testing (VT-2) examinations required by Section Xl, and the continuing periodic leakage inspections, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 69 of 71 Relief Request 11 ON 002 35.0 Weld #3HP-498-14 35.1. ASME Code Component(s) Affected Unit 3 Pipe to Reducer Weld #3HP-498-14, Summary Number 03.C5.21.0066 35.2. Applicable Code Edition and Addenda ASME Boiler and Pressure Vessel Code, Section XI, 1998 Edition through the 2000 Addenda 35.3. Applicable Code Requirement IWC-2500, Table IWC-2500-1, Examination Category C-F-i, Item Number C5.21 Figure IWC-2500-7(a), 100% Volume Coverage of Examination Volume C-D-E-F 35.4. Impracticality of Compliance Component configuration:

  • Surface 1: Pipe* Surface 2: Reducer* NPS: 2.0 in.* Thickness:

0.436 in.Scanning requirements are described in 10CFR.50.55a (b)(2)(xv)(A)(1). The aggregate coverage was calculated from the following: 600 shear waves obtained 50% coverage in one axial direction (Si -pipe)* 60° shear waves obtained 30.25% coverage in one axial direction (S2-reducer)* 30° shear waves obtained 50% coverage in one circ. direction (CW).* 300 shear waves obtained 50% coverage in one circ. direction (CCW).The aggregate coverage was calculated to be (50% + 30.25% + 50%+ 50%)/4 = 70.10%.The limitation of the component was caused by the taper configuration of the reducer. In order to scan all of the required volume for this weld, the component would have to be redesigned, which is impractical. Page 70 of 71 Relief Request 11 ON 002 The Oconee Inservice Inspection Plan allows the use of Code Case N-460, which requires greater than 90% volumetric coverage. Therefore, the available coverage will not meet the acceptance criteria of this Code Case.35.5. Proposed Alternative and Basis for Use This weld was examined using procedures, equipment, and personnel qualified in accordance with ASME Section XI, Appendix VIII. No alternative examinations are planned for the weld during the current inspection interval.Radiography (RT) is not a desired option because RT is limited in the ability to detect service induced flaws. Additionally, radiography has not been qualified through performance demonstration. 35.6. Duration of Proposed Alternative This request is proposed for the duration of the fourth inservice inspection interval, currently scheduled to end on July 15, 2014.35.7. Justification for Granting Relief Ultrasonic examination of the weld for the item number 03.C5.21.0066 was conducted using personnel, equipment, and procedures qualified in accordance with ASME Section XI, 1998 Edition with the 2000 Addenda.The system leakage test performed each inspection period in accordance with Table IWC-2500-1; Examination Category C-H requires a VT-2 visual examination to detect evidence of leakage. This test and VT-2 examination provides additional assurance of pressure boundary integrity. In addition to the above Code required examinations (volumetric and pressure test), visual observations performed during operator rounds provide additional assurance that in the event leakage did occur through this weld, it would be detected and proper action taken.Duke has examined the weld/component to the maximum extent possible utilizing approved examination techniques and equipment. Based on the acceptable results for the coverage completed by the volumetric examination, the pressure testing (VT-2) examinations required by Section XI, and the continuing periodic leakage inspections, it is Duke's position that the combination of examinations provides a reasonable assurance of quality and safety.Page 71 of 71 AT TACHMENJ PASE I OF ýýft uke Site/Unit: Oconee I Summary No.: 02.8 Workscope: UT Vessel LAamination 2 3.110.0012 Procedure: Procedure Rev: Work Order No.: NDE-640 4 01793547 Outage No.: O2-23 Report No.: UT-08-169 Page: 1 of I ISI Code: 1998 Cat./Item: B-D 113.110 Location: Drawing No.: ISI-OCN2-002

== Description:==

Nozzle to Shell System ID: 50 Component ID: 2-PZR-WP26-7 Size/Length: N/A Thickness/Diameter:* 6.187/5.75 CS Limitations: Yes -See Report UT-08-170 For Coverage Calculations Start Time: 0920 Finish Time: 1220 Examination Surface: Inside D1 Outside [] Surface Condition: 0GROUND Lo Location: 9.2.3 Wo Location: Centerline of Weld Couplant: ULTRAGEL II Batch No.: 07225 Temp. Tool Mfg.: D.A.S Serial No.: OCQUA33079 Surface Temp.: 60 °F Cal. Report No.: CAL-08-1 92 Angle Used 30 .45 45T 60 60TJ Scanning dB 33 Indication(s): Yes D- No C] Scan Coverage: Upstream [] Downstream LI CW[E]' CCWJ Comments: Results: Accept -- Reject [] Info C]Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes Examiner Level 11-N Date Reviewe,. , ' Signatur Date Tucker, David K. 11 /24/2008 4 /1 /K(A 4 /,2$ýo Examiner Level 11,N _. Signature Date Site Review Y Signature Date Dean, Steven 11/24/2008 N/A Other Level N/A Signature Date ANII Review DatatUe Da N/A 11/24/2008 0 AI1ACHMENTA P A 6E Z OF ý(Site/Unit: Oconee /. 2 Summary No.: 02.B3.110.0012 Workscope: ISI UT Vessel LAamination Procedure: Procedure Rev.: Work Order No.: NDE-820 3 01793547 Outage No.: 02-23 Report No.: UT-08-1 70 Page: 1 of 2 Code: 1998 Cat./Item: B-D /B3.110 Location: Drawing No.: ISI-OCN2-002

== Description:==

Nozzle to Shell System ID: 50 Component ID: 2-PZR-WP26-7 Size/Length: N/A Thickness/Diameter: 6.18715.75 CS Limitations: Yes -See Attached Limitation Report Start Time: 0920 Finish Time: 1220 Examination Surface: Inside [ Outside [ Surface Condition: GROUND Lo Location: 9.2.3 Wo Location: Centerline of Weld Couplant: ULTRAGEL II Batch No, 07225 Temp. Tool Mfg.: D.A.S Serial No.: OCQUA33079 Surface Temp.: 60 °F Cal. Report No.: CAL-08-193, CAL-08-194, CAL-08-195, CAL-08-196 Angle Used 0 ,45 45T 60 60T 35135T Scanning dB 63.5 63.5 72.'0 57.8 Indication(s): Yes D No g Scan Coverage: Upstream EVJ Downstream [_vJ CW [v CCW R Comments:** 70' Axial Scan -72.0 scan dB**Results: Accept D Reject [ Info J _Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes Examiner Level I-N Date Reviewer Signature Date Tucker, David K. 111f24/2008 Rsd'~/ /-: ~~Examiner Level Il-N S";ignature Date f Site Review Signature Date Dean, Steven 11/24/2008 N/A Other Level N/A Signature Date ",, /,Signature Date N/A 111/24/20.08, vf -I. (1, M1tFA6E DUKE ENERGY COMPANY ISI LIMITATION REPORT Summary #: 02.B3.110.0012 Component ID 2-PZR-WP26-7 remarks:[ NO SCAN SURFACE BEAM DIRECTION Nozzle Configurition El LIMITED SCAN El 1 Z2 E 1 (E 2 Z cw ccw FROM L N/A to L N/A INCHES FROM WO 1.25 to Beyond ANGLE: 0 0 [ 45 E 60 other 35' FROM 0 DEG to 360 DEG El NO SCAN SURFACE BEAM DIRECTION D] LIMITED SCAN El- 1 [ 2 El 1 2 F- cw 7 ccw FROM L to L INCHES FROM WO to ANGLE: E- 0 El 45 El 60 other FROM DEG to DEG-- NO SCAN SURFACE BEAM DIRECTION D] LIMITED SCAN E) 1 l2 El 1 F- 2 -cw 7 ccw FROM L to L INCHES FROM WO to ANGLE: El 0 El 45 El 60 other FROM. DEG to DEG El NO SCAN SURFACE BEAM DIRECTION ElLIMITED SCAN 1 E2 E 1 E] 2 E cw El ccw FROM L to L INCHES FROM Wo to Sketch(s) attached ANGLE: El 0 E] 45 El 60 other FROM. DEG to DEG yes El No Prepared By: Dave Tucker ?ie: 1 eDae II Date: I 1/24/2008 Sheet 2 of 2 Reviewed By: Date-: Aut.rized Ins Date'. .A o e opc I .S//0 LU-L:J 4- .-Oconee 2 PZR Shell to Sampling Nozzle Item No. 02.B3.110.0012 Weld No. 2-PZR-WP26-7 Weld Coverage Scan 52 Cw CCw Base.Metal Coverage Scan Si Cw, CCw 0 Degree Scan Angle 35, 45, 60 35, 45, 60 35,45 35, 45 Angle 35, 45, 60 35,45% Coverage Obtained 68.9 0.0 0.0 0.0 68.9/4 = 17.2%% Coverage Obtained 70X63 37.45 108.08/2 = 54.0%% Coverage Obtained i7.5%Aggregate Coverage = Weld + Base + 0 Degree = 108.72/3 = 36.2%Inspector/Date: n cPI r/ s/O0 Attachment I of 7 t2 -A~~~_A T TA.C HENT A PASEE ~£~O.A/~" C~.NSIA'G /SA~p1pLmg /% zLt6-' -~. ~-z.e~.1.I)L I N~~7< "1 I,;-,.di TII it I'I I g~A~x4&~ ;~ ,.,~- 2 ' ~ -'0' -____ ---Cr~, -.ATTACHMENT A PASt (, AF 'X)--" /YOZ:Zc6 LJcriAI .J~.N$IA'& /S7LIA'c~ /Y c~-r~ N b X---;'~2;z~-I ~ ~A (~pj2 I /I., - 3Lq, -6 17'~ 7 ~ 'Z-Alt"AC;OEINI A,-~PASE e O/, L)~$NG A'Sx Pthv" I'YIZ ,z6e 6-"f"L.I ý "6,ýL" F-;"__, A';~A. I Ii.I !ij I?.~.s p ,4WýE ( ZL/I ~ p7.~ /Ai~cD,?h/~ SAV~( (x/ii*r1~ --~4 d$ ~A I AT AK R T PASE 0~ OF A rt 1i f ý 77 S.(4~ r- ~oCuigh6> (i JI$/VC S,? t'PLIAIG ZZ4 Sc P uý~~I '1ý1-4 PA6E/O F 'AFuACYNCC:-A(7 7C~25cI~Z~~/ 77 NG A/ z-A!!!I siMcc~h -p i~ft/k ~ PABE IJ OF ~Site/Unit: Oconee / 2 Summary No.: 02.89.11.0031 Workscope: ISI UT Pipe W,,d Examination Procedure: Procedure Rev.: Work Order No.: NDE-600 17 01794228 Outage No.: 02-23 Report No.: UT-08-132 Page: 1 of 4 Code: 1998 Cat./Item: B-J /B9.11 Location: Drawing No.: ISI-OCN2-010

== Description:==

Casing to Safe End System ID: 50 Component ID: 2-PIB2-8 Size/Length: N/A Thickness/Diameter: 2.780/33.5 SS Limitations: Yes -See Attached Limitation Report Start Time: 1138 Finish Time: 1207 Examination Surface: Inside 7 Outside [ Surface Condition: GROUND Lo Location: 9.1.1.2 Wo Location: Centerline of Weld Couplant: ULTRAGEL. I Batch No.: 07125 Temp. Tool Mfg.: Lutron Serial No.: MCNDE32795 Surface Temp.: 86 'F Cal. Report No.: CAL-08-128, CAL.08-O 29, CAL-08-1 30 Angle Used 0 45 45T 60 60L Scanning dB 60 60 62 Indication(s): Yes 7 No W Scan Coverage: Upstream [ Downstream D CW W CCW DV Comments: FC 08-03 Results: Accept 0 Reject R Info J_Percent Of Coverage Obtained > 9 0%: No Reviewed Previous Data: Yes-E x a m in e r L e v e l 1 l-N n.t.Da t es i g re .Leeper, Winfred C. (/620 Signat eate Examiner Level I1-N Signatur Date Site Review Signature, Date Griebel, David M. 11/6/2008 N/A Other Level N/A Date AMl IR'view .4Y // /, Date_.=~~~ .. ... e ... .,a.. .e. .N/A ~~~~~~11/6/2008 U /& I 4'Z 7 AlT1ACHMiHl , /PAUE /2ý OF 071 DUKE ENERGY COMPANY ISI LIMITATION REPORT Summary #: 02,B9,11.0031 Component ID 2-PIB2-8 i remarks: Z NO SCAN SURFACE BEAM DIRECTION 0Due o RCP Configuration-LIMITED SCAN 1 -] 2 1--] cw E] ccw _FROM L N/A to L N/A INCHES FROM WO i.0" to Beyond ANGLE: E 0 E] 45 N 60 other FROM 0 DEG to 360 DEGj-- NO SCAN SURFACE BEAM DIRECTION[] LIMITED SCAN 1 2 D1 2 F cw F ccw FROM L to L INCHES FROM WO to ANGLE: M 0 Li 45 11 60 other FROM DEG to DEG-- NO SCAN SURFACE BEAM DIRECTION-LIMITED SCAN El 1 2 l--1 D2 cw ccw FROM L to L INCHES FROM WO to ANGLE: fl 0 fl 45 [] 60 other FROMý DEG to DEG , NO SCAN LIMITED SCAN SURFACE BEAM DIRECTION[1i 1 12 0 1 lD2 ElcW Fccw FROM L ANGLE: to L[1 0 F-1 445 INCHES FROM WO to, 11 60 other DEG Sketch(s) attached Z yes FROM DEG to-No Prepared By: Winfred Leeper Reviewed By: s Summary No.: 02.69,11.0031 Examiner: Leeper, Winfred Exammer: Griebel,.David:M. 0ther: N/A upplemnital Report AIIACOIENI A ,ý N PAUE /3 OF 91 18-132 Reviewer: Page: 3 of 4-Ce.e: ! io Level: 1l-N Level: If.N Leve): NIA Site Review: .AN:! Revievvw , 1 .. 1" '. .. .Comments: Ak'~L1,~ ~C¢A'3t~r~ 3.3w rn~T~Sketch or Photo-~OOR'L E'00s 1-11 1---,I-7.... i mr" r ~e J~AC~£I I doY~I/I I C ~Jc~ ~ f1§4Z (S (3 (s Deteri ,- Site/Unit: Oconee / 2-, Summary No.: 02,9.111.0031 Workscope: ISI mination of Percent Coverage for UT Examinations -Pipe Procedure: Procedure Rev.: Work Order No.: NDE-600 17 01794228 Outage No.: 02-23 Report No.: UT-08-132 Page: 4 of 4 45 de1 Scan 1 Scan 2 Scan 3 Scan 4% Length X% Length X 100.000 % Length X 100.000 % Length X% volume of length / 100 =% volume of length 1100 =50.000 % volume of length / 100 =50.000 % volume of length /100 =" total for Scan I" total for Scan 2 50,000 % total for Scan 3 50.000 % total for Scan 4 Add totals and divide by # scans = 50.000 % total for 45 deg Other deg -60 (to be used for supplemental scans)The data to be listed below is for coverage that was not obtained with the 45 deg scans.Scan I Scan 2 Scan 3 Scan 4 100.000 % Length X 0.000 ..% volume of length /100 =100.000 % Length X 50.000 % volume of length 1100 =% Length X % volume of length /100 =% Length X % volume of length 1100 =0.000 % total for Scan 1 50.000 % total for Scan 2% total for Scan 3% total for Scan 4 Percent comIleete coverage Add totals for each scan required and divide by # of scans to determine; 37.500 % Total for complete exam Site Field Supervisor: Date: ./LILL 7 I IZ MAE 15 OF 91 Duke Site/Unit: Oconee / 2 Summary No.: 02.B9.11.0031 Workscope: ISI UT Pipe W ,d Examination Procedure: Procedure Rev.: Work Order No.: NDE-830 0 01 794228 Outage No.: 02-23 Report No.: UT-08-134 Page: 1 of 2 Code: 1998 Cati/tem: B-J /B9.11 Location: Drawing No,: ISI-OCN2-010

== Description:==

Casing to Safe End System ID: 50 Component ID: 2-PIB2-8 Size/Length: N/A Thickness/Diameter; 2.780/33.5 SS Limitations: None Start Time: 1210 Finish Time: 1242 Examination Surface: Inside 3 Outside E Surface Condition: GROUND Lo Location: 9.1.1.2 Wo Location: Centerline of Weld Couplant: Temp. Tool Mfg.: Lutron Serial No.: MCNDE32795 Surface Temp.: Cal. Report No.: CAL08-131, CAL-08!A132 Angle Used 10 45 145T6 60 60L j 70L Scanning dB Indication(s): Yes D No [ Scan Coverage: Upstream o Downstream 1 Comments: Scanned at 70.0 dB to maintain a 30% noise level. ** Scanned at 75.0 dB to maintain a 30% noise level.***Best effort exam of upper 2/3 of weld to supplement coverage.Results: Accept W Reject C Info 0 Percent Of Coverage Obtained > 90%: ... Reviewed Previous Data: Yes ULTRAGEL II 86 0 F Batch No.: 07125 C W o CCW0,/ 0 ke Supplem :al Report AIIACHMENT A~MAE 14, OiF 13 Reporll\o.: Page: Summary No.: 02.B9.11.0031 Examiner: Griebel, David M. ," , Examiner: Leeper. Winfred C. /Other: N/A Level: IM-N Level: i1-N Level: N/A Reviewer: Site Review: NIA ,.. ...ANI. Review: (. A8-134 2 of 2 Dale: D at e'___Comments:==n: --z--n t,1 /z* " Sketch or Photo: I t I:1 f t 1 I 1 1-1 313 f, Sz _ke UT Base Me Lamination ~Enorgy AI1ACHMENT PA6E /7 UF g Site/Unit: Oconee / 2 Summary No.: 02.B9.11.0058. Workscope: ISI 1 2EOC23 Procedure: NDE-640 Procedure Rev.: Work Order No.: 4 01794246 Outage No.: N/A Report No.: BOP-UT-08-026 Page: 1 of 2 Code: 1998/2000 Addenda Cat./Item: N/A Location: N/A Drawing No.: ISI-OCN2-009

== Description:==

Casing to Safe End System ID: 50 Component ID: 2-P1B1-8 Size/Length: N/A Thickness/Diameter: 2.330/33.5 SS Limitations: None Start Time: 0935 Finish Time: 1015 Examination Surface: Inside Outside Surface Condition: AS GROUND Lo Location: 9.1.1.1 Wo Location: Centerline of Weld Couplant: ULTRAGEL II Batch No.: 07125 Temp. Tool Mfg.: Lutron Serial No.: MCNDE32795 Surface Temp.: 86 -F Scanning dB: 35 Cal. Report No.: CAL-08-133 Ind Amplitude Position One Posidon Max Position, Two Loss .-.. --Remarks Sack Wall Full Screen Li WVI W2 MP LM W1 W2 M 0 L2 WI W2 MP NRI Comments: Results: Accept 0] Reject f Info ] Initial Section XI Exam Percent Of Coverage Obtained > 90%: Yes Reviewed Previous Data: NO.Examiner Level IM-N Siqnature Date Revie,, r- Signature Date Muirhead, Barry A. 11/5/2008 ///Examiner Level II.N r' Date Site Review' Signature Date Hollis, Jacob 11/5/2008 N/A Other Level N/k"< "Sig'nature Date ANliI Review i,. '7Sgnature Date/ 115/2008 / C/ PbDu~de Summary No.: 02.B9.11.0058 Examiner: Muirhead, Barry A.Examiner: Hollis. Jacob Other: NIA Suppleme;.,al Report PA6E /1 Of 31 Report No.: Page: Level: I1-N Level: IM-N Level: N/A Reviewer: Site Review: NIA ANII Review: BOP-UT-08-026 2 of 2 Date://./. Date: Date: _______Comments: Sketch or Photo: Z:\UT'DDEAL\ProfileLine2.jpg CL 41, 2.,' .16 ZY' 2 4 V 2J* I 7 ' ,r 2 , p./Zsr /.~ Z.I /zw /zj'- A ~ I .aK /?I"7,g /2.jy Rc( AT TA CHM~hIA PAHE O2 F(Duke Site/Unit: Oconee / 2 Summary No.: 02.B9.11.0058 Workscope: ISI UT Pipe Weld Examination Procedure: Procedure Rev.: Work Order No.: NDE-600 17 01794246 Outage No.: 02-23 Report No.: UT-08-131 Page: 1 of 4 Code: 1998 Cat./Item: B-J /B9.11 Location: Drawing No.: ISI-OCN2-009

== Description:==

Casing to Safe End System ID: 50 Component ID: 2-PIS1-8 Size/Length: N/A Thickness/Diameter:. 2.780/33.50 SS Limitations: Yes -See Attached Limitation Report Start Time: .1030 Finish Time: 1100 Examination Surface: Inside D Outside ?JI Surface Condition: GROUND Lo Location: 9.1.1.2 Wo Location: Centerline of Weld Couplant: ULTRAGEL It Batch No.: 07125 Temp. Tool Mtg.: Lutron Serial No.: MCNDE32795 Surface Temp.: 86 °F Cal. Report No.: CAL-08..128, CAL-08-129, CAL-08-130 Angle Used 0 5T 6" " 0L Scanning dB 6 60 62 Indication(s): Yes 7 No Scan Coverage: Upstream Y) Downstream .CW l CCW jj Comments: FC 08-03 Results: Accept C] Reject o Into 71 Initial Section XI Exam Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: No Examiner Level I1-N re Date ýýReview Signatu.e '/t Leeper, Winfred C. 11/6/2008 /Examiner Level I,.N Signato bDate.7 Site Revieew Signature Date Griebel, David M,-- 111/62008. N/A Other Level N/A -Signatur DaIte REI Sig ure Date N/A 11/6/2008 VN Dat/ ATIACHMENT A PA6E 2oO F 91 DUKE ENERGY COMPANY .ISI LIMITATION REPORT Summary #: 02.B9.11.0058 Component ID 2-P1B1-8 remarks: Z NO SCAN SURFACE BEAM DIRECTION DUe to RCP Configuration [] LIMITED SCAN 0:1 L -2 [ K 2 []cw L- ccw FROM L N/A to L N/A: INCHES FROM WO ib.: to Beyond ANGLE: 13 0 13 45 El 60 other FROM 0 DEGto 360 DEG 1- NO SCAN SURFACE BEAM DIRECTION 13 LIMITED SCAN 1-- 132 [- 132 []cw L]ccw FROM L to L INCHES FROMWO to _ _ANGLE: 30 1 45 E1 60 other FROM DEG to _ DEG I-1] NO SCAN SURFACE BEAM DIRECTION ____Lý LIMITED SCAN [M3i [1 2 El 1 31 2 r cw -Ccw I FROM L to L INCHES FROM WO to _ANGLE: [ 0 [] 45 1 60 other FROM DEG to DEG F1 NO SCAN 1- LIMITED SCANýOM L to NGLE: F1 0 13 45 SURFACE BEAM DIRECTION 13' 13F2 Ell F2 13cw1ccw FF L 13 60 other INCHES FROM WO to Ab FROM DEG to __DEG. I Sketch(s) attached E yes LNo Prepared By: Winfred Leeper Ii-06-2008 4 kuthor I, - Eflil. " Aer IVEA.-ergy. Supplen tal Report AIIACHNENI tl\PA6E? 0 F FReport No.: 08-131 3 of 4 Summary No.: 02.89.11.0058 Examiner: Leeper, Winfred C L e~el: 11-N Examiner: Griebel, David M. Level: I1-N Other: N/A Leve): NIA Reviewer: Site Review;AN:I Reviewv Date:.~Z Comments: azov~j Lr~A o~ ~k%~j~ ~c()q,~ £ '2 i 7~t.t6:!ZEý 7-Z<.6,0 1 .-~ ! 'ell I.-?1 z~jr g&1Z~&.I I , do L, 12- 'ý' 7 I/(_________ ---.~>Q- 0i Cc (& c2 D 90keDete r' Site/Unit: Oconee / 2-Summary No.: 02.B9.11.0058 Workscope: ISI nination of Percent Coverage for UT Examinations -Pipe Procedure: Procedure Rev.: Work Order No.: NDE-600 17 01794246 Outage No.: 02-23 Report No.: UT-08-131 Page: 4 of 4 45 den Scan I Scan 2 Scan 3 Scan 4% Length X% Length X 100.000 % Length X 100.000 % Length X 50.000 50.000% volume of length / 100 =% volume of length / 100 =% volume of length/ 100 =% volume of length/100 =% total for Scan 1% total for Scan 2 50.000 % total for Scan 3 50.000 % total for Scan 4 Add totals and divide by # scans = 50.000 % total for 45 deg Otherdeo-60 (to be used for supplemental scans)The data lo be TwIed below is for coverage that was not obtained with the 45 deg scans.Scan 1 Scan 2 Scan 3 Scan 4 100.000 % Length X 0.000 100.000 % Length X 50.000% Length X% Length X% volume of length / 100 =% volume of length /100 =% volume of length /100 =% volume of length /100 =0.000 % total for Scan 1 50.000 % total for Scan 2% total for Scan 3% total for Scan 4 Percent complete coverage Add totals for each scan required and divide by # of scans to determine; 37.500 % Total for complete exam Site Field Supervisor: /e~1-.K Date,. /1: 11 0 AttACHME~f A ,iD Ke UT Pipe W..J Examination MA6E23 OF 81 0%'Energy. Site/Unit: Oconee / 2 Summary No,: 02.B9.11.0058 Workscope: ISI Procedure: NDE-830 Procedure Rev.: Work Order No.: 1 01794246 Outage No.: 02-23 Report No,: UT-08-133 Page: I of 2 Code: 1998 Cat./Item: B-J /B9.11 Location: Drawing No.: ISI-OCN2.009

== Description:==

Casing to Safe End System ID: 50 Component ID: 2-PIB1-8 Size/Length: N/A Thickness/Diameter: 2.780/33.5 SS Limitations: None Start Time: 1101 Finish Time: 1131 Examination Surface: Inside [ Outside [ Surface Condition: GROUND Lo Location: 9.1.1.2 Wo Location: Centerline of Weld Couplant: ULTRAGEL ti Batch No.: 07125 Temp. Tool Mfg.: Lutron Serial No.: MCNDE32795 Surface Temp.: 86 OF Cal. Report No.: CAL-08-131, CAL-08-132 Angle Used 0 45[45T 660 0 GL 70L Scanning dB -Indication(s): Yes Fl No W Scan Coverage: Upstream Downstream Dv CW [ CcW Comments:* Scanned at 70.0 dB to maintain 30% noise level. **Scanned at 75.0 dB to maintain a 30% noise level.***Best Effort Exam of upper 2/3 of weld to supplement coverage -Non Section XI Exam -Info Only Results: Accept E., Reject D] Info [] Initial Exam Percent Of Coverage Obtained > 90%: Reviewed Previous Data: No mne L lDaze Reviewer Signature Date Griebe,, David M. 11/6/20Q81 Examiner -Level. II.N Date Site Review Signature Date Leeper, Winfred C. ..11/6/2008 N/A Other Level N/A " nature Date ANlFeview , Date NA11/6/20, Duxe Suppleme,..al Report IýL 0Energy.AJ1ACHM N ' A PA6E2q OF g1 Report No.: Page: Summary No,: 02.B9.11.0058 Examiner: Griebel, David M. "'Z-d)ýExaminer: Leeper, Winfred C.. 1/ýI Other: NIA 4 -" " Level: 14;N Level: I-N Level: N/A Reviewer: Site Review: N/A ,,.ANII Review: 0 ?. , I"-UlL.UT-08-133 2 of 2 Dat:o: I./p.Date: Comments:/--/- W/Sketch or Photo: 130,4zE WF!5I'I I I i 52.z Plb6i- --ke OVE',nergy-UT Base Met,, .amination AIIACHMENIA PAWEý Of 9(Site/Unit: Oconee /Summary No.: 02.E Workscope: ISI:2 39.11,0067 Procedure: Procedure Rev.: Work Order No.: NDE-640 4 01794421 Outage No.: N/A Report No.: BOP-UT-08-031 Page: 1 of 2/2EOC23 Code: 1998/2000 Addenda Cat./Item: B-J/B9.11 Location: N/A Drawing No.: 2-53A-10

Description:

Valve 2LP-1 to Pipe System ID: 53A Component ID: 2-53A-10-3 Size/Length: N/A Thickness/Diameter: 1.125/.12.0 SS Limitations: None Start Time: 1350 Finish Time: 1400 Examination S Lo Location: Temp. Tool Mf Cal. Report No urface: Inside D Outside 25 9.1.1.1 Wo Location: fg.: D.A.S Serial No.: CAL I50 Surface Condition: AS FC Centerline of Weld)UND MCNDE32825 Couplant: ULTRAGEL II Surface Temp.: 66.3 °F Batch No.: 07125.Scanning dB: 59.5 Comments: Results: Accept o Reject []Info 0]Initial Section XI Exam

  • Duxe Supplemeh...al Report A1IACHMENT A PA 6E 4 OF F/Report No.: Page: Summary No.: 02.89.11.0067 Examiner:

Johnson, Garland Examiner: Tucker. DavidK Other: N/A Level: Il-N Level: i-N Level: N/A Reviewer: Site Review: N/A. -. .-,ANII Review: ,jei , .BOP-UT-08-031 2 of 2 Dae:/ /3i, 3'O Date: Date, Comments: Sketch or Photo: Z:\UT\IDDEAL\ProfileLine2,jpg 1.1,3 0J22\IALL~ýPIPE-A11ACRitENf ý3 P A 6 EZ7 0F tl 1 S Item No.: 03.B3.110.0008 Press Weld No.: WP26-6 Inspector/Date: David Tucker Sampling Nozzle to Shell Nozzle Surface 2 LIZ 600 RL 600 RL Shell Surface 1 V or-8 AIIACHMENr 46 P46E2 OF p Site/Unit: Oconee /Summary No.: 03.B Workscope: UT Vessel Examination -- 3 3.150.0001 3 Procedure: Procedure Rev.: Work Order No.: NDE-3630 1 1813760 Outage No.: 03-24 Report No.: UT-09-187 Page: 1 of 9 ISI Code: 1998 Cat.!Item: B-D /B3.150 Location: Drawing No.: 1-N32389-2

== Description:==

Nozzle to Channel Body System ID: 51A Component ID: 3-LDCA-IN-2V Size/Length: N/A Thickness/Diameter: 0.875/3.000(SS Limitations: See supplemental sheets Start Time: 10958 Finish Time: 1043 Examination Surface: Inside LI Outside fZ Surface Condition: AS GROUND _Lo Location: CL of nozzle next to circ weld Wo Location: Centerline of Weld Couplant: ULTRAGEL ii Batch No.:, 07225 Temp. Tool Mfg.: Lutron Serial No.: MCNDE32795. Surface Temp.: 72 *F Cal. Report No.: CAL-09-228 thru CAL-09-232 Angle Used 0 45 45T 1:Ar 6V.4%J 70L Scanning dB 53.6 54.0 69.8 73.7 54.6 Indication(s): Yes 0 No R] Scan Coverage: Upstream [] Downstream CW I CCW W]Comments: Scanning dB lowered from +14dB to maintain 2:1.siggnal to noiseratio FC 09-01 Results: Accept n Reject R Info L_Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes Examiner Level 1I-N Signature Date v Signature Ransom, Greg J. 4/30/2009/( 7s io Examiner Level Il-N v w 4i , Date Site S u Tucker, David K. 4302009 Review Other Level NIA -Signature Date ANII Review J , jSsignaqtue ,, Date N/A$CO6C IQL P ISupplemental Report AITACHMENT PWA6E2? OF (Report No.: UT-09-187 Page: 2 of 9 Summary No.: 03.13.150.0001 Examiner: Ransom, Greg J. ,A. .Level: I1-N Examiner: Tucker, David K. Level: 11-N Other: N/A Level: N/A Reviewer: Site Review: ANII Review:)$~aAIA I1~Date: Date: Date: 5-1/3-e*Comments: Sketch or Photo: Z:\UT\OUTAGES\Oconee\3EOC24\O3.B3.150.0001.bmp ATTACHMENTV Letdown Coplar Nozzle, to-Channel Body (Radius Vi ew.)PAE3 F6 Weld No.:

  • f,(A-1r( -Iterr! No. 0 ý3. P.Ao. I 00o0 A~~~~~ .6hA< I 2/ -C ~~-* /R7:.. -' -C , z.C- rx 1'k J-41'Ai 2l-,- .lýk/-r 0. h4~V-1 Scale: 1" = 1"~6~A~11K ~*Ofrq Letaown CooiJr Nozzle to Channel Body (Radis View1)PA8 51 Ah*
  • i Veld No.: ".-ir -e -id --v Item ýNo.:C3 <1ooc1 S~.4M'~)t~.U

((.~\Je~Af~dZ -,I~r) -O7~ C AvIACL (4~;t)It ", -,_I I a-AIE E 7-/.,1 ' (IC.L 34~ --- (1A~7~h~I-14 eS.q I%LJ ,o I Scale: 1 " = 1" I, AIIACHMENT E Letdown Cool Nozzle to Channel Body( Radius 5 Weld No.: -* -- 7v Itemn No. o-3 13 -yflP, iK pooo.2 A4F X--iZY'A&I ' (rWI.ýAvy A -'irt/-\hJ6 12 (tX,61tAr(C-xt o **t 0 0 1b / 65-.J ~*) ~c7qje/Scale: 1"= 1" OP47 A IIAC HMEN T 13'P A 6E 3ý3 F ý, /I Letdown Cooler Nozzik, to Channel Body Weld No.: hLrA -Ttt.- 7v/Iteh-i No.: i o~k~tE r~ ~drI4L- AEC&. riF AL,, Nozzle S2\jJ1 r) AIW~A P7;Cirs 30ý4Lx I-m' , 7k 85-11L.- Z'K_ _ I]Channel Body -S I C Scale: I"= 1"'4'A A4~I( ~ AIIACHMENT B PAGE 3Lq Of 6 Letdown Cooler Nozzic co Channel Body We)ld No.:-- S-L FC-'-) I- 7 V i 7-,i Seý IYA t QJUr? AtL Itein No.: ~.3iD0 p CD& V'I L " It- r. 1-"7 ABC- 7-z I. ./ I IL 7 , , ) *,- C-I. (,,;.I- Z- --Lou.,. AC? "- L A 7041<0 Scale: I" = I" 7 A ýq AIIACHMEN! 5 !PASE ?,S OF 61 Letdown Cooler Nozzi, to Channel Body Weld No. " ",l --d- A Item No.: pp,/A rý c -n .? ,*--e P7<,,s-Z, 7 70 X ,-ýY C~ r~i 0 h301, 3o 1ýx.B7.J I (...y;;7 z q 7 /-, /1, (1 5V41 ý/--(A~j5 ~5-.lC- p Scale: I'= 1" 77ZT~'~. oc~ 9 I ISupplemerical Report ATTACHMENT B ME 31, OF 61 Report No.: UT-09-187 Page: 9 of 9 Summary No.: 03.B3.150.0001 Examiner: Ransom, Greg Examiner: TuckerNDvdAK. Other: N/A Reviewer: -1 g i=, Level: II-N Level: Il-N Level: N/A Site Review: ANII Review: I /.Date: Date: Date: ____.___e ~[4-~(Commnts:Site Field Supervisor: David K. Zimmerman 0510512009_ Sketch or Photo: Z:UIUAEýcne3O213B.5.0ie.P Letdownf Coo,[cr.NzI obne* 1t~mNo.. ~ 3.+/-$cO~O~f ~14 3 a~O t 9e 77, 718 ri 4ag T6_____ 'adir~ 21-Zus~V PAUE ýý7 OF 641 Site/Unit: Oconee I Summary No.: 03.B Workscope: UT Vessel Examination 3 3.150.0002 ISI Procedure: Procedure Rev.: Work Order No.: NDE-3630 1813760 Outage No.: 03-24 Report No.: UT-09-188 Page: 1 of 9 Code: 1998 Cat./Item: B-D /B3.150 Location: Drawing No.: 1-N32389-2

== Description:==

Nozzle to Channel Body System ID: SIA Component ID: 3-LDCA-OUT-5V Size/Length: NIA Thickness/Diameter: 0.87513.O00iss Limitations: See supplemental sheets Start Time: 1001 Finish Time: 1045 Examination Surface: Inside J Outside [] Surface Condition: AS GROUND Lo Location: CL of nozzle next to circ weld Wo Location: Centerline of Weld Couplant: ULTRAGELII -Batch No.: 07225 Temp. Tool Mfg.: Lutron Serial No.: MCNDE32795 Surface Temp.: 72 F Cal. Report No.: AL-09-228 thru CAL-09-232 Angle Used 0 45 45T ,W 6o.riL 7oL Scanning dB 53.6 54.0 69.8 73.7 54.6 Indication(s): Yes F1 No [] Scan Coverage: Upstream [ Downstream [ CW [] CCW R]Comments: Scanning dB lowered from +14dB to maintain 2:1 signal to noise ratio FC 09-01 Results: Accept 0 Reject n- Info E]Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes Examiner Level 1e-N ignatUre Date Reviewer.. rA Signature Date Ransom, Greg .3. 4/30/2009 Examiner Level Il-N .... Date Site Review Signature, Date Tucker, David K.~4/30/2009 Other Level JN/A- .Signature Date ANII Review S Date NA OIoB c.s Acu'c L... Supplemencal Report ATTACHMENI B PA6E3S 64 Report No.: UT-09-188 Page: 2 of 9 Summary No.: 03.B3.150.0002 Examiner: Ransom, Greg J.Examiner: Tucker, David.K.Other: NIA Level; 11-N Level: i1-N, Level: NIA Reviewer: Site Review: ANII Review:>~A n1o~Date: Date: Date:_______ /j,,,-- ,,- ... .. ... * -,'l, , V Comments: Sketch or Photo: Z:\UT\OUTAGES\Oconee\3EOC24\O3.83.150.0002.bmp Lercdown Cool. Nozzle to Channel Body ( Radius View E'9p F (4 Weld No.: Item No. :-ý -[ T)rA -r) t rr -:ý v_Wc)z-S&A$A I --NZA ~-A A -, &Algý--tA I Af--66ý16-ev,;7 ::WIZ.7-I ,Z.A- .Z n.C r)Al, C~% 1ý F~<n4~t -~ *1-Scale: 1V= I"~jY~2 O((//Cw AIIACHMENT 5 Lewiown Cool-.r Nozzle to Channel Body (Radius View A 0 F Weld No.Item No. :: -I 173¢ A -ot 0,r". * (3'). 0' , ..A[5c 7 )It,,"lr * { l -"7-to-:ý .-7*~(1,t #- 4 ,.-.,3 -&go" A~I o , , ,, 1 o ) "- ,o .Scale: I" = 1" A c ýZ, p e, ý ý- a,-C) '//SoiAq 4 oF q LeLdo n Coot-r Nozzle to Cha.inel Body (Radius View.. ...ý -,: .. .... ..... .. : , ..._ , ,.R a4 1 GE q1 Weld No.: Item No. :*'k- I MeA -ot, rr- <,,/03 -a'3 -1 f5 0, OND 34S6~KACA.Lfi:UkCnr -(C iw I n, .1,-,r C Li -( 7-i w ... .. .... 2 il~1Li~L8, Ak~~,.frZ 1 s D tI17c- -C r VZL-xO, )C O 0--i Q Scale: i= I"'I'o Letdown Cooler Nozzlk to Channel Body A11ACH4ENT 1B PASE 42-/DF I' /Weld No.: Item No. : fT--5V (2 o, 0?~2L~ .~ ..~ A A 17 /-- I 1= ý 7-A BCt-p J%7.S1-As. .7 -Ci " I-3 ~ Z- 77,- 1.4~-r~~u-1z I& .~Channel Body -SI I I-L C-P e Scale: 1" = I" A irý g, , 1/: ntllgn /,1ý7<.._6 PASE qS3 OF (1.Letdown Cooler Nozzkt to Channel Body Weld No.: Item No.~,-~h(-pLr- -0 3 -! .ý 1!50 .oo?.7 CDr.-.141;; -C T)-1~~4.-I-'p 1 I.. ~ t -rz C 77. 77, A Channel Body -S I Scale: 1"= I" r 7 1F I AIIACHMENT PAGE'9q1 OF 5 Letdown Cooler Nozzk- to Channel Body Weld No.: Item No. : 3-( ThA-c~u1-~v -.Z R :;,. 5C O- W 2 I-0*261.C ll/A.Scale: 1" = 1"'5'gzj I AML. A Supplemental Report PASE q!! OF 6(Report No.: UT-09-188 Page: 9 of 9 Summary No.: 03.B3.150.0002 Examiner: Ransom, Greg J././ ýExaminer: Tucker, David K. -Other: N/A Reviewver: Level: Il-N Level: fl-N Level: N/A Site Review: _ANII Review: I Date: Date: Date: ________V, ......V Comments: Site Field Supervisor: David K. Zimmerman 05105/2009 '/ z /,.//6"_?;) Sketch or Photo: PAO~M~PRO Axial, I -52.7%Uiric 4 Axia$ KAI Mak44l CArS2~ ~45$~QQ S-~ 0'-0 54,ý8~~$i A11ACHt4MI PASE *9(ý OF ~Site/Unit: Oconee /Summary No.: 03.E Workscope: UT Pipe Wtad Examination 3 19.11.0068 ISI Procedure: Procedure Rev.: Work Order No.: NDE-830 1 1813961 Outage No.:: 03-24 Report No.: UT-09-219 Page: 1 of I Code: 1998 Cat./Item: B-J lB9.11 Location: Drawing No.: ISI-OCN3-011

== Description:==

Nozzle to Safe End System ID: 50 Component ID: 3-PDAI-1 Size/Length: N/A Thickness/Diameter: 2.330133.50/SS Limitations: Single Sided Exam Start Time: 1133 Finish Time: 1215 Examination Surface: Inside El Outside P Surface Condition: AS GROUND Lo Location: 9.1.1.1 Wo Location: Centerline of Weld Couplant: ULTRAGEQIII Batch No.: 07225 Temp. Tool Mfg.: D.A.S Serial No.: MCNDE32795 Surface Temp.: 75 1 F Cal. Report No.: CAL-09-271 and CAL-09-272 Angle Used f 0 45 45T J 60 601 70L Scanning dB 68.0 70.0 Indication(s): Yes El No S] Scan Coverage: Upstream [2 Downstream El CW 66 CCW G]Comments: Non Code Exam Results: Accept El Reject E] Info R]Percent Of Coverage Obtained > 90%: No Reviewed Previous: Data: No //I ~~~~~~~~~..... ..... ..... ... ... .'" !" .......i .....'Examiner Level I-N Slgn3at, e Date Site Review Signature Date Griebel, David M. , -" 518/2009 Other Level N/A (Signature Date ANII Review Stn .'Iture Date'NIA Cc'6 A11ACHMENT PA13E' OF Site/Unit: Oconee / 3 Summary No.: 03.B9.11.0068 Workscope: 1SI UT Pipe Wwd Examination Procedure: Procedure Rev.: Work Order No.: NDE-600 17 1813961 Outage No.: 03-24 Report No.: UT-09-221 Page: 1 of 5 Code: 1998 Cat .ltem: B-J 1B9.11 Location: Drawing No.: ISI-OCN3-011

== Description:== , Nozzle to Safe End System ID: 50 Component ID: 3-PDA1-1 Size/Length: N/A Thickness/Diameter: 2.330/33.50/SS Limitations: See Supplemental Report Start Time: _.h215 Finish Time: 1239 Examination Surface: Inside [] Outside [ Surface Condition: AS GROUND _Lo Location: 9.1.1.1 Wo Location: Centerline of Weld Couplant: ULTRAGE4 II Batch No.: 07225 Temp. Tool Mfg.: D.A.S Serial No.: MCNDE32795 Surface Temp.: 75 °F Cal. Report No.: CAL-09-278, CAL-09-279, and CAL-09-280 Angle Used 0145 45T 60 60L Scanning dB 62.0 67.0 71.0 Indication(s): Yes [l No R Scan Coverage: Upstream El Downstream [] CW [] CCW []Comments: FC 08-03 Results: Accept E] Reject RJ Info L_Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes Examiner Level II-N tuDate Reviewer Signature Date Leeper. Winfred C. 5/8/2009 .. ..Examiner Level Il-N ature Date -Site Review Signature ..Daee Dean, Steven 5/8/2009 Other Level NIA Signature Date ANII Review ......Signure, Date NIA ~4OCC/L PAGE 4 OF 6i DUKE POWER COMPANY ISI LIMITATION REPORT ComponentlWeld ID: 3-PDAI-1 Item No: 03.B9.11.0068 remarks:[ NO SCAN SURFACE BEAM DIRECTION Due to RCP configuration and LI LIMITED SCAN Ej I ; 2 0 1 E] 2 Z cw 0 ccw material type (cast stainless FROM L N/A to L N/A INCHES FROM WO N/A to N/A steel).ANGLE: D 0 N 45 0 60 other N/A FROM N/A DEG to N/A DEG L] NO SCAN SURFACE BEAM DIRECTION Li LIMITED SCAN 0 1 [E 2 [E 1 [: 2 [-1 cw [:] ccw FROM L __.,, _-to L INCHES FROM WO to __,, ANGLE: Di 0 Li 45 E) 60 other FROM DEG to DEG Li NO SCAN SURFACE BEAM DIRECTION DLIMITED SCAN Li1 Li2 i1 1 2 i cw [ccw FROM L to L INCHES FROM WO to ANGLE: EL 0 Li 45 [L 60 other FROM DEG to DEG Li NO SCAN Li LIMITED SCAN SURFACE i1 L-2 BEAM DIRECTION LI I Li 2 1i cw i-- ccw i " FROM L to L INCHES FROM WO to ANGLE: EL 0 Li 45 L 60 o ther FROM DEG to DEG'Sketch(s) attached 0 yes L No v.- Determination of Percent Coverage for UT Examinations -Pipe Site/Unit: Oconee / 3 Summary No.: 03.B9.11.0068 Workscope: ISl Procedure: Procedure Rev.: Work Order No.: NDE-600 17 1813961 Outage No.: 03-24 Report No.: UT-09-221 Page: 3 of 5 45 deg Scan 1 Scan 2 Scan 3 Scan 4% Length X % volume of length!_L100 % Length X % volume of length /100 100.000 % Length X 50.000 % volume of length /100 =100.000 % Length X 50.000 % volume of length /100 =...... .......... ... -% ..total-for-*Scan .1.% total for Scan 2 50.000 % total for Scan 3 50.000 % total for Scan 4 Add totals and divide by # scans = 50.000 % total for 45 deg Other deg -60 (to be used for supplemental scans)The data to be listed below is for coverage that was not obtained with the 45 deg scans.Scan 1 100.000 % Length X 50.000 % volume of length / 100 =Scan 2 100.000 % Length X 0.000 % volume of length / 100 =Scan 3 % Length X % volume of length / 100 =Scan 4 % Length X % volume of length /100 =50.000 % total for Scan 1 O0000 % total for Scan 2% total for Scan 3% total for Scan 4 Percent complete coverage Add totals for each scan required and divide by # of scans to determine; 37.500 % Total for complete exam Site Field Supervisor David K. Zimmerman ,,, ' Date: Supplemb..tal Report 11ACHMENT S A BE Report No.: UT-09-221 Page:, 4 of 4 Summary No.: O3.B9.11.0068 Examiner: Leeper, Winfred C. /(}.4...L'/ It-N Examiner: Dean, Steven Level: Il-N Other: NIA Level: N/A Reviewer: Site Review: ....___.. ..... .ANII Review: V/ -6 Date: f r-2.Date: je.m Comments: r--A"A ct, .IIJ ASe(r 33t; ~nc~,>I I 7'A 1 J l-~.o6~L -I N 'I0 SI Af~~~c- E .'~--I SýI- ý-ý(~1~Dý 1440*6 MM Supplemw 1 ,tal Report ATfIACHMEHT S PArF 5/ 0 F1 Report No.: Page: Summary No.: 03.B9.11.0068 Examiner: Leeper, Winfred C. Level: Il-N Examiner: Dean, Steven Level: It-N Other: N/A Level: N/A, UT-09-221 5 of 5 Date: 11_2..0 Date: Date: 5-/2 Reviewer: Site Review: ANII Review: Comments:-/-/ 0W >Sketch or Photo: 10-- 1--m V.3'c 0 AerAX44i4 A-V 77 l I Site/Unit: Oconee I 3 Summary No.: 03.B9.11.0074 Workscope: ISI UT Pipe Weid Examination A11ACHMET?,A6E.2. OF 6A Outage No.: 03-24 Report No.: UT-09-220 Page: 1 of I Procedure: Procedure Rev.: Work Order No.: NDE-830 1 1813975 Code: 1998 CatJItem: B-J /B9.11 Location: Drawing No.: ISI-OCN3-014

== Description:==

Nozzle to Safe End System ID: 50 Component ID: 3-PDB2-1 Size/Length: N/A Thickness/Diameter: 2.330133.50/SS Limitations: Single Sided Exam Start Time: 0920 Finish Time: 0934 Examination Surface: Inside LI Outside [] Surface Condition: AS GROUND Lo Location: 9.1.1.1 Wo Location: Centerline of Weld Couplant: ULTRAGEL II Batch No.: 07225 i Temp. Tool Mfg.: D.A.S Serial No.: MCNDE32795 SAnface Temp.: 75 'F Cal. Report No.: CAL-09-273 and CAL-09-274 Angle Used 0 45 45T 60 60L 70L Scanning dB 68.0 70.0 Indication(s): Yes El No j] Scan Coverage: Upstream [] Downstream CJ CW [] CCW R]Comments: Non Code Exam Results: Accept El Reject F) Info ____Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: No Examiner Level Il-N Signature Date Reviewer Signature Date Ransom, Greg J. 51812009 5 " " Examiner Level Il-N " ., Si, .Date Site Review Signature Date Griebel, David M. 518/2009 Other Level N/A Signa'ture Date ANII Review , Date N/A 33to 6 -C.fw -C AIIACHM~ENI B PAISE 53ý Of: ýI Site/Unit: Oconee / 3 Summary No.: 03.B9.11.0074 Workscope: ISI UT Pipe Weld Examination Procedure: Procedure Rev.: Work Order No.: NDE-600 17 1813975 Outage No.: 03-24 Report No.: UT-09-222 Page: 1 of 5 Code: 1998 CatJltem: B-J 119.11 Location: Drawing No.: ISI-OCN3-014.

== Description:==

Nozzle to Safe End System ID: 50 Component ID: 3-PDB2-1 Size/Length: N/A Thickness/Diameter: 2.330133.501SS Limitations: See Supplemental Report Start Time: 0853 Finish Time: 0917 Examination Surface: Inside j] Outside [] Surface Condition: AS GROUND Lo Location: 9.1.1.1 Wo Location: Centerline of Weld.. Couplant: ULTRAGEL! II Batch No.: 07225 Temp. Tool Mfg.: D.A.S Serial No.: MCNDE32795 Surface Temp.: 75 °F Cal. Report No.: CAL-09-275, CAL-09-276, and CAL-09-277 Angle Used 0 45 45T 60 60L j Scanning dB 62.0 67.0 71.0 Indication(s): Yes [] No R] Scan Coverage: Upstream El Downstream 2] CW FvI CCW R1 Comments: FC 08-03 Results: Accept E: Reject 2) Info _-_Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yep Examiner Level II-N natye Date Reviewer/j Signature ..Date Leeper, Winfred C. A f ... .. ..5 15-' k ...Examiner Level II-N S,, ,unL- Date Site Re Signature Date Hollls, Jacob 5. 5 .9/2009 Other Level N/A Signature Date ANII Review Date N/A .... A CP f OIL e~eiz 5.. zT2. .. A11ACHMEWT B P A 6E 5q O DUKE POWER COMPANY ISI LIMITATION REPORT Component/Weld ID: 3-PDB2-1 Item No: 03.19.11.0074 remarks:[ NO SCAN SURFACE BEAM DIRECTION Due to RCP configuration and F-] LIMITED SCAN r- 1 [ 2 0 1 rI 2 M cw ccw mrterial type (cast stainless FROM L to L INCHES FROM WO to steel).ANGLE: El 0 ED 45 0 60 other N/A FROM N/A DEG to N/A DEG LI NO SCAN SURFACE BEAM DIRECTION[7LIMITED SCAN l- I El 2 [1 1 [I 2 I- cw 0 ccw FROM L to L INCHES FROM WO to _ANGLE: L] 0 [] 45 Li 60 other .. FROM DEG to __ .DEG Li NO SCAN SURFACE BEAM DIRECTION i LIMITED SCAN E] 1 [7 2 i- 1 [7 2 [] cw [i- ccw FROM L to L_________ INCHES FROM WO to _ANGLE: E] 0 Li 45 EL 60 other FROM DEGto DEG I L NO SCAN SURFACE BEAM DIRECTION Li LIMITED SCAN FROM L t Eli IE]2 D 1 l 2 Eicw Diccw oL INCHES FROM WO to Sketch(s) attached I'9 Deter]k" Site/Unit: Oconee / 3SummaryNo.: 03.B9.11.0074 Workscope: ISI ruination of Percent Coverage for UT Examinations -Pipe Procedure: Procedure Rev.: Work Order No.: NDE-600 17 1813975 Outage No.: 03-24 Report No.: UT-09-222 Page: 3 of 5.......... S c a n 1 .... .... .. ...Scan 2 Scan 3 100.000 Scan 4 100.000%. Length-X. .% Length X% Length X 50.000% Length X 50.000% voal m-e--oflen-gth-/-MGO _ ___ 6%totai-for Scan 1% volume of length / 100 = % total for Scan 2% volume of length / 100 = 50.000 % total for Scan 3% volume of length / 100 = 50.000 % total for Scan 4 Add totals and divide by # scans = 50.000 % total for 45 deg Other deg -60 (to be used for supplemental scans)The data to be listed below Is for coverage that was not obtained with the 45 deg scans.Scan 1 Scan 2 Scan 3 Scan 4 100.000 % Length X 50.000 100.000 % Length X 0.000% Length X% Length X% volume of length / 100 =% volume of length /100 =% volume of length /100 =% volume of length /100 =50.00.0 % total for Scan 1 0.000 % total for Scan 2........__ % total for Scan 3......% total for Scan 4 Percent complete coverage Add totals for each scan required and divide by # of scans to determine; 37.500 % Total for complete exam Site Field Supervisor: David K. Zimmerman I C/ Date: r,____. ____ 101- a-, 6, Supplemtxital Report A11ACHMENI B P A6E Of (e?(Report.No.: UT-09-222 Page: 4 of 5 Summary No.: 03.B9.11.0074 Examiner: Leeper, Winfred Examiner: HolUis, Jacob Other: N/A Reviewer:- Level: Il-N Level: It-N Level: N/A Site Review-ANII Review: Date:.-. (2.a.Date: Date: j,/2 -Comments: Fe.., --* ......,..A o,, 4P L'( 1r'tI4 A;Sketch or Photo:* ~ ~ y Chi z ...I I'-)bg- ýy $-11 'LJ&&.I-~I Rý9ý& I T- u) Gi I I~L4~L~C~L L~tI 7.Q(,r~'~ -~I/I .46~ 1. A2~Cazz:1.~A.I $~L- ~g 0 (~J~A(7 e;~ LL~C.s--t Q' Supplemtwltal Report Summary No.: 03.B9.11.0074 Examiner: Leeper, Winfred C. Level: Il-N Examiner: Houlls, Jacob 4!-tZLevel: 11-N Other: NIA Level: NIA Reviewer: Site Review: ANII Review: z~g 6'L~F AS"E_ OF 6/O Report No.: UT-09-222 Page: 5 of 5 Oateo: 1-2 Date: Date:_______ ?-Comments: Sketch or Photo: A ~R'CPL I I SI-IIX I. ATIACHHM1 PAHE5S3 Of Site/Unit: Summary No.: Workscope: UT Pipe Weid Examination Oconee / 3 03.C5.21.0024 ISI Procedure: Procedure Rev.: Work Order No.: PDI-UT-2 C.01816627 Outage No.: 03-24 Report No.: UT-09-181 Page: 1 of 4 Code: 1998 Cat./ltem: C-F-1/C5.21 Location: Drawing No.: 3-51A-52

Description:

Valve 3HP-105 (Forged SS) to Pipe System ID: 51A Component ID: 3-51A-52-44 Size/Length: N/A Thickness/Diameter: 0.43813.000/SS Limitations: No circumferential scan on downstream side of weld due to taper Start Time: 1501 Finish Time: 1608 Examination Surface: Inside LI Outside [ Surface Condition: AS GROUND Lo Location: 9.1.1.1 Wo Location: Weld Centerline Couplant: ULTRAGELill Batch No.: 07225 Temp. Tool Mfg.: D.A.S Serial No.: MCNDE32827. Surface Temp.: 89 °F Cal. Report No.: CAL-09-222 and CAL-09-223 Angle Used 0. 45 *f45T 60 Scanning dB 50.2 50.2 60.7 Indication(s): Yes E] No 2] Scan Coverage: Upstream [] Downstream I] CW E) CCW El Comments: FC 08-01, 08-04, 09-02 Results: Accept E] Reject I2] Info E_Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes Examiner Level Il-N 'g'.. Date Review-. Signature Date Ellis II, Kenneth R. 2/212009 [, ., -og Examiner Level NIA Signature Date Site Review y Signature Date N/A __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _Other Level N/A Signature Date ANII Review OSg nature Date N/A J... 0 C. Deteri ME Site/Unit: Oconee / 3_ -6ummary No.: 03.C5.21.0024 ._.. Workscope: ISt mination of Percent Coverage for UT Examinations -Pipe Procedure: Procedure Rev.: Work Order No.: PDI-UT-2 C 01816627 Outage No.: 03-24 Report No.: UT-09-181 Page: 2 of 4 45 dee Scan 1 % LengthX .... .olumeof-engthll.Q= Scan 2 % Length X % volume of length / 100 =Scan 3 100.000 % Length X 50.000 % volume of length / 100=Scan 4 100.000 o% Length X 50.000 % volume of length / 100 =--/ototal-for-SGan-1-- % total for Scan 2 50.000 % total for Scan 3 50.000 % total for Scan 4 Add totals and divide by # scans = 50.000 % total for 45 deg Other deg -60 (to be used for supplemental scans)The data to be listed below is for coverage that was not obtained with the 45 deg scans.Scan 1 Scan 2 Scan 3 Scan 4 100.000 100.000% Length X 100.000 % volume of length /100 =% Length X 100.000 %volumeoflength /100=% Length X % volume of length 1100 =% Length X % volume of length /100 =100.000 % total for Scan 1 100.000 % total for Scan 2% total for Scan 3% total for Scan 4 Percent complete coverage Add totals for each scan required and divide by # of scans to determine; 75.000 % Total for complete exam Site Field Supervisor. David K. Zimmerman Date: 4/2912009 AI1ACHMENT PAGE /,1OF OI Supplemental Report Report No.: UT-09-181 Page: 3 of 4 Summary No.: 03.CS.21.0024 Examiner. Ellis 11, Kenneth R.Examiner: NIA Other: NIA Level: I1-N Level: N/A Level: N/A Reviewer: Gary JMoss Level'II Site Review: N/A ANII Review: Jacob C. Scholl Date: 5/5/2009 Date: Date: 5/5/2009 Comments: Sketch or Photo: Z:\UTXOUTAGES\Oconee\3EOC24\O3.C5.21.0024T&Ct.JPG-LI P~Ae ce ~n-A I I J 4~IA. i ~AIIACHMENI 4T PAGE OF DUKE POWER COMPANY ISI LIMITATION REPORT Component/Weld ID: 3-51A-52-44 Item No: 03.C5.21.0024 r~marks: I NO SCAN SURFACE BEAM DIRECTION Nb scan from centerline toward I LIMITED SCAN CD I El 2 E] I [] 2 CW CCW vlve duetoconfiguration FROM L N/A to L N/A INCHES FROM WO 0 to beyond ... ____. ....... .....ANGLE: [: 0 [ 45 [1 60 other FROM .o DEG to 360 DEG["- NO SCAN SURFACE BEAM DIRECTION iLIMITED SCAN [] 1 [ 2 i]-I 11 2 E] cw El-7Ccw FROM L to L INCHES FROM WO to _ _ANGLE: [E 0 LI 45 L] 60 other FROM DEG to DEG LI NO SCAN SURFACE BEAM DIRECTION i] LIMITED SCAN -- I El 2 I-1 [2 El cw ccw FROM L to L INCHES FROM WO to _ANGLE: Li 0 [] 45 n] 60 other ___ FROM DEG to DEG i NO SCAN SURFACE BEAM DIRECTION E] LIMITED SCAN Ii L i2 E]i [1 2 -cw l ccw FROM L to L INCHES FROM WO to _ Sketch(s) attached ANGLE: Li 0 L] 45 L60 other FROM DEG to DEG yes Li No Prepared By: Kenneth Ellis Level: II Date: 02/02/2009 Sheet 4 of t Reviewed By: Date: AuthoriVn por:" Date: Site/Unit: Oconee I 3 Summary, No.: N32389-3 WJ-32 Workscope: PSI UT Vessel E%ýamination AITAOMENT c PAGE I OF ýProcedure: NDE-3630 Procedure Rev.: 0 Work Order No.: N/A Outage No.: N/A Report No.: BOP-UT-06-112 Page: 1 of 5 Code: 1998 thru 2000 Addenda Cat.1item: NIA Location: N/A Drawing No.: OM 201.-3235.002

== Description:==

Inlet Channel Body to Chemical Connector System ID: Component ID: N32389-3 WJ-32 Size/Length: NIA ThicknesstDiameter .875 18.620 Limitations: Yes -See Attached Limitation Report Start Time: 2122 Finish Time: 2218 Examination S Lo Location: 3urface: Inside Outside Iv' Surface Condition: AS GROUND............. ___Wo Location: Centerline of Weld Couplant: ULTRAGEL 11_ , J , Batch No:f~O 4.-3Z Temp. Tool Mfg.: FISHER Serial No.: MCNDE 27219 Surface Temp.: 68 °F Cal. Report'No.: CAL-06-297,,CAL.06 298:CAL.O6.299,CAL-06-3001 Angle Used I 0 4 45T 4 6T L f-.. 7' 70t1I Scanning dB 52- 4S! 1 W 5. , ,53-Indication(s): Yes v' No. Scan Coverage: Upstream ivv Downstream kdI CW vii CCW Comments: FC 06-02* Lo = CL of nozzle adjacent to Circ. Weld Scanning Db's reduced from reference +14 to maintain 2:1 signal to noise ratio Results: Accept j,'l Reject I j Info I1 PSI Examination Percent Of Coverage Obtained > 90%: .c>- Reviewed Previous Data: ._No PAF I 2 IACMNT DUKE POWER COMPANY ISI LIMITATION REPORT Component/Weld ID: N32389-3 WJ-32 Item No: N/A remarks'[ NO SCAN SURFACE BEAM DIRECTION Due to Nozzle El LIMITED SCAN Ni El 2 Z I N] 2 Z cw 2 ccw FROM L 0+3" to L o04" INCHES FROM WO CL+-.1 to Beyond ANGLE: E] 0 0 45 0 60 other 70 FROM DEG to DEG El NO SCAN SURFACE BEAM DIRECTION Taper on Chemical Connector[ LIMITED SCAN 11 1 0 2 1 1 Z 2 0 cw Z ccw FROM L to L INCHES FROM WO +0.6 to +1.5 ____. _____.... .. .........ANGLE: 0i 0 Z 45 0 60 other 7o FROM o DEG to 360 DEG LI NO SCAN SURFACE BEAM DIRECTION[1 LIMITED SCAN El1 [E 2 0 1 E] 2 El cw El ccw FROM L to L INCHES FROM WO to ANGLE: El 0 El 45 El 60 other FROM DEG to DEG E. NO SCAN El LIMITED SCAN SURFACE BEAM DIRECTION, E 1i El 2 ] 1 El 2 E[ cw El ccw FROM L to L ANGLE: El 0 El 45 El 6n. INCHES FROM WO Sketch(s) attached 0,to DEG to .DEG FROM Z yes E] No Prepared By: Jay Eaton'05/1=4(006 1 Sheet 3 of 5 Reviewed By::.1 -~--.~-~ C-Let Down Cooler -Chemical Connector to Channel Body% Coverage Calculations Weld No.,:~32~3~S~r3 ~Y~-3l 0=8.625" 0.875" Weld Length = 27.1" Total Inspection Area = 2.28 sq. in.% Length Limited due to nozzle-= 6" 1 27.1" x 100 = 22.1%A.ore-cate Coverage Calculation Axial Scans 22.1% of length x 96.5% of the volume of length / 100 = 21.3%77.9% of length x 97.4% of the volume of length / 100 = 75.9%Aggregate coverage Axial scans =.*'i'+ 75.9 = 97.2%Circ. Scans 100% of length x 78.1% of the volume of lengt/ 100 = 7 8.1%Total = (97.2 + 78.1) 12 = 87.7% Aggregate Coverage)L~4I~Inspector Date: ,<A-rLAL0$4D1rTD So?-Ufncx...lz' 4,1411,11 Page I of 5 -A-. I I IACH-MEtNTC .-4 etdown Cooler Chemical C ,nnector to Channel BoAt 6 Total Exam Area Weld No. : i~0~ZL3~ -3 Item No. : t)IA e JA cc, 14 Dv- Z-I V, Vt,)Scale: 1" = 1" Y,,,, ~s e-Iz3-0JOV-r-0 Iea'. Z ofý- _etdown Cooler Chemical i-innector to Channel B o.I, .OF q3 Area Examined -Circ. Scan Weld No. : i\)3Z3~A -3 Item No. : I Area Not Examined = 0.5 sq. in.Area Examined= 2.28 -0.5 / 2.28 x 100 = 78.1%LIZ]ckes4' 1 1~Ca(I c/0 450 450 Scale: 1" = 1 "ý> -10ý '61z3fa!L (30?-OT-- o(o -i iz&-rMC-%A M e-Dýr -M'?A~me 3 ~n1::S -etdown Cooler ChemicalC-.nnector to Channel Bod4Ayf-5 OF Area Examined -Axial Scans Weld No.: z-38g-3 u,)Y-32-Item No. :-Itt, Area Not Examined = 0.05 + 0.01 = 0.06 sq. in.L[II = Area Examined = 2.28 -0.06 / 2.28 x 100 = 97.4%Ck~J e The-'(hg /,~-Tube Sheet -S2 Channel Body -SI Scale: 1V-z 1"'? 44 q Al 1ACHMENT C ,,etdown Cooler Chemical C-nnector to Channel BodyAGE-7 OF qS Area Examined @ Nozzle -Axial Scans Weld No.: -3 J q-3 t--7-= Area Not Examined = 0.05 + 0.01 + 0.02 = 0.08 sq. in.Area Examined 2.28 -0.08 / 2.28 x 100 = 96.5%I 0.05 sq. in.sq. inl i 0.02 sq.Item No. " 3,_1A zzle Channel Body -S I Av%(' ~ ~ ~ X ýk Jz 6-j --0a 06 k)~ e'o40 4ýde-6'3-e&- S2 700 450 600 450 Iti 4 I/1 Scale: " = 1"?PAL-cr 'S Ofr' Al ltAHMENTIC PA6E--ý OF ý'3 Site/Unit: Oconee! 3 Summary No.: N32389-3 WJ-33 Workscope: PSI .UT Vessel Examination Procedure: Procedure Rev.: Work Order No.: NOE-3630 NIA Outage No.: N/A Report No.: -. BOP-UT-06-113 Page: 1 of 2 Code: 1998 thru 2000 Addenda Cat./Item: NIA Location: N/A Drawing No.: OM 201.-3235.002

== Description:==

Inlet Tube Sheet Nozzle C to Channel Body System ID: Component ID: N32389-3 WJ-33 Size/Length: N/A Thickness/Diameter .875/ 3.0 Limitations: Yes -See Attached Limitation Report. Start Time: 2122 Finish Time: 2218 Examination Surface: Inside , : Outside !v]Surface Condition: AS GROUND Lo Location: .WO Location: Centerline of Weld Couplant: ULTRAGEL II Temp. Tool Mfg.: FISHER Serial No.: MCNDE 27219 'Surface Temp.: 68 -F Cal. Report No.: CAL-06-297, CAL.O8.2S8;CAL-06-299,.CAL.O06:30i)CAL-.06301 Angle Used 0. j 45 45T 6oLI 6f' 7-tL-. I Scanning dB Y 2' 4N LWr U5o m CC Indication(s): Yes! No i.jScan Coverage: Upstream IYJ Downstream ik W Wv CCW IoI Batch o31 Z5 Comments: FC 06-02'Lo = CL of nozzle adjacent to Circ. Weld Scanning Db's reduced from reference +14 to maintain 2:1 signal to noise ratio Results: Accept !./! Reject I Info PSI Examinatio Percent Of Coverage Obtained > 90%: .Reviewe d Previ ous Data: No Examiner Level ii ~aueDate Revie rSignature Date Eatlon, Jay A. ../820 Examiner Level N/ASgntrDaeStRvewintu ae NVA NaeSieR/A wY IDi Other Level NIA Signature Date ANlII Re lvew to, @,l ~tre ,.- Date.(-J (,J1 iL-L-O.Let Down Cooler ' Nozzle to Channel Body%0 Coveraqe Calculations Weld No.: Z38~-5 0S33 Axial Scans Along Axis of Pipe = 100% of the Length x 45.2% of the Volume = 45.2%Along Radius of Pipe = 100% of the Length x 60.0% of the Volume = 60.0%Average = 45.2% + 60.0% / 2 = 52.6%Circ. Scans Along Axis of Pipe = 100% of the Length x 55.5% of the Volume 55.5%Along Radius of Pipe = 100% of the Length x 81.7% of the Volume = 81.7%Average = 55.5% + 81.7% / 2 = 68.6%Total = (52.6 = 68.6 ) 1 2 = 60.6% Aggregate Coverage Inspector Date: " 1Z A:'Page I of¶.. S-3 ) 0(1.1 w ATIACHMENT C P A 6E7-0 0F 'T3 Letdown Cooler Nozzle to Channel Body Weld No. 5 ZfA-3 Item No. C: j Total Exam Area = 2.72 sq. in.Scale: I" = 1"--I Z-510o(.ATfPcýr"6-W--M T'Ald, Z OF 7 Letdown Cooler Nozzle to Channel Body Area Examined -Circ. Scans ATIA*CHMENT C PAGE 71 OF q Weld No. : 0 5"Z. 3 Sq -"5 L- --53 Item No. : L--Z LIII3 Area not Examined,= 0.81+ 0.40 = 1.21 sq. in.Area Examined = 2.72 -1.21 / 2.72 x 100 = 55.5%450 450 450 )&3 .t/Scale: 1" = 1" 450 k~~Arnb~wj5ýCr-rD --r i- I3-?A kf-. 3or 7 Letdown Cooler Nozz, 1 e to Channel Body Area Examined -Axial Scans AIIAtHUMNiN C.PAGE 7-~F9 Weld No. -t3:ý'Z-31bg -3 %-ý-:53 Item No. : A Li2 Area not Examined = 1.49 sq. in.Area Examined = 2.72 -1.49 / 2.72 x 100 = 45.2%Scale: V = 1" 450?i~'t~cEL. q o67 AIIACHMERT C L~tdown Cooler Nozzle to Channel Body ( Radius View.i F q-3 Weld No. : 03z,-ý611-3 IIZY3-3 Item No. : Total Exam Area = 2.30 sq. in.Scale: 1" 1" S-3 C, Cooler Nozzle to CL.annel Body Area Examined -Axial Scans ( Radius AT AACHMENI C Item No. :_ 4k -Weld No.:

  • ____z___ -3 .El LII Area not Examined = 0.92 sq. in.Area Examined = 2.30 -0.92 / 2.30 x 100 = 60.0%700 600 4;50'sae. I" Af--,ýýkMCýJV -fD -BD? ')T--GL -'r'-7 etddown Cooler Nozzle to CGiannel Body Area Examined -Circ. Scans (Radius vi~AME1C PAGE I~OF 9 Weld No.: 7..J~ -Z-_33 Item No. : p2s I'k L--i Area not Examined = 0.42 sq. in.Area Examined = 2.30 -0.42 / 2.30 x 100 = 81.7!450 Scale: I I~~ 3o?-3/-oal,-

?A-)ý -~71a7 AT tA*CHMEN~ T P A 6 E , Site/Unit: Oconee 1 3 Summary No.: N32389-3 WJ-35 Workscope: PSI UT Vessel Exaimination Procedure: Procedure Rev.: Work Order No.: NDE-3630 0 N/A Outage No.: NIA Report No.: BOP-UT-06-114 Page: 1 of 5 Code: 1998 thru 2000 Addenda CalIltem: NIA Location: NIA Drawing No.: OM 201.-3235.002

== Description:==

Outlet Channel Body to Chemical Connector System ID: Component ID: N32389-3 WJ-35 Size/Length: NJA Thickness/Diameter: .875 1 8.620 Limitations: Yes -See Attached Limitation Report Start Time: 2122 Finish Time: 2218 Examination Surface: Inside Outside !yi Surface Cone Lo Location: ... ........_ __ Wo Location: Centerline of Temp. Tool Mfg.: FISHER Serial No.: MCNDE 272 Cal. Report No.: CAL-06o297, CAL.06a298. CAL-06-299. C.Angle Used 0 45 45,T 6t-1 -G'1 I- TL(Scanning dB 52 54-_Indication(s): Yes iV, No Scan Coverage: Up Comments: FC 06-02 Lo = CL of nozzle adjacent to Cire. Weld Scanning Db's reduced from reference +14 to maintain 2:1 signal to noise ratio Results: Accept l1v Reject I I Info 1--l PSI Examination Percent Of Coverage Obtained > 90%: .,.O -fl "f Re'Viewed PrevioL J1 lition: AS GROUIND Neld Couplant: Batch N -. ,I 19 Surface Temp.: 68 °F AL-06-300, CAL-O6-301, stream IvI Downstream lv]CWI k1 CCW I#1 is Data: No Examiner Level III Date Reviewer Signature Date Eaton, Jay A. 5/118/200(6 Examiner Level NIA StV ature Date site Review V Signature 1 NO Date NIA NIA Other Level NiA Signature ... .ANI 1 l,(eview < 1:' " nature .Date N IA ..... ......... .... .... ....6 . A I IA. CJ{ ME 1Tl DUKE POWER COMPANY! P ISI LIMITATION REPORT Component/Weld ID: N32389-3 WJ-35 Item No: NIA remarks:[ NO SCAN SURFACE BEAM DIRECTION Due toNozzle ii LIMITED SCAN Z 1 E] 2 Z I Z 2 Z cw Z ccw FROM L 0+3" to L 0o3- INCHES FROM WO CL+-.i 'to Beyond ANGLE: [] 0 0 45 [] 60 other 7o FROM DEG to DEG.[] NO SCAN SURFACE BEAM DIRECTION Taper on Chemical Connector[ LIMITED SCAN 01 0 2 Z I Z 2 Ncw Z ccw FROM L to L INCHES FROM WO +0.6 to +1.5 _ANGLE: F] 0 (0 45 2) 60 other 70 FROM o DEG to 36o DEG El NO SCAN SURFACE BEAM DIRECTION[] LIMITED SCAN 0 1 D 2LI []1 2Lcw I[-1 ccw FROM L to L INCHES FROM WO to ANGLE: 0I 0 El 45 [] 60 other FROM DEG -to PEG E] NO SCAN EL LIMITED SCAN SURFACE I 1 2 BEAM DIRECTION LI M Li 2 DI w i cow FROM L ..... to L INCHES FROM WO _to ANGLE: Li 0 EL 45 LI 69 ther FROM, DEGto DEG Sketch(s) attached Z yes 0 No Priapared By: Jav Eaton.Dýate: 051,1 S12006 L.U Let Down. Cooler -,Chemical Gonnector to Channel Body% Coveraqe Calculations Weld No.: 03nib3S -3 O=lift =8.625" 0.875" Weld Length = 27.1" Total Inspection Area 2.28 sq. in.% Length Limiteddue to nozzle:='.6" 127.1" x 100 = 221%Agg regate Covera-ge Calculation Axial Scans 22.1% of length x 96.5% of the volume of length /100 = 21.3%77.9% of length x 97.4% of the volume of length / 100 = 75.9%Aggregate coverage Axial scans ='97.2%zi.3 Circ. Scans 100% of length x 78.1% of the volume of length.) 100 = 78.1%Total = (97.2 + 78.1)1 2 = 87.7% Aggregate Coverage Inspector I Date: ptlej TIguf"Nýý? Inspcto I Dte:L~fC 0 Pge~f 'k4cA~-r¶D ~o?-~y~, -Page ý of S ..,etdown Cooler Chemical ( )nnector to Channel BodY 6 TEAMN1 Tt al/9 F Aq3 Total Exam Area Weld No.: wb3Z?3q -3 Item No. : 1. .ý)JA 0qe, Scale: I " == I " S'a-II V=' I~f Ist-ATTP~f- LA 6-F- 0r-0 -?Ake Z,01ý Cooler Chemical C innector to Channel Bod§TAc$M, t c Area Examined -Circ. Scan GEO Weld No. : Item No. :-Area Not Examined = 0.5 sq. in.= Area Examined = 2.28 -0.5 / 2.28 x 100 = 78.1%LIII]k.D 450 45'Scale: 1" = 1 AM-rWA" 3rtn -Do?- --PA6Z 3 of-ý .. etdown Cooler Chemical ()nnector to Channel C Area Examined -Axial Scans Weld No.:-3 Item No.: r'IA Area Not Examined = 0.05 + 0.01 = 0.06 sq. in.= Area Examined = 2.28 -0.06 / 2.28 x 100 = 97.4%CoL4 ek I CO Tube -S2 Channel Body -S I?Pck6; f Of--'5 Scale: 1"= V ,--Jetdown Cooler Chemical C-nnector to Channel Bod§ IAMENO (1 Area Examined @ Nozzle -Axial Scans Item No.: -[A Weld No.: M = Area Not Examined = 0.05 + 0.01 + 0.02 = 0.08 sq. in.LIZ= Area Examined = 2.28 -0.08 / 2.28 x 100 = 96.5%-.0... ,05 sq. in, 0.01 sq. in. 0.602 sq.-4ebe Ghee -S2 600 45 0 600\ 700 459 Channel Body -S I ATMM-k Jx-CG Scale: 1" = 1V?AnC '5o0rz' AIIACCHMENT C PAGE aF 93 Site/Unit Oconee / 3 Summary No.: N32389-3 WJ-36 Workscope: PSI UT Vessel Examination Procedure: NDE-3630.Procedure Rev.: 0 Work Order No.: NIA Outage No.: N/A Report No.: BOP-UT-06-115 Page: 1 of 2 Code: 1998 thru 2000 Addenda Cat./Item: NIA Location: N/A Drawing No.: OM 201.,3235.002

== Description:==

Outlet Tube Sheet.Nozzle D to Channel Body.System ID: Component ID: N32389-3 WJ-36 Size/Length: NIA Thickness/Diameter: .875 1 3.0 Limitations: Yes -See Attached Limitation, Report Start Time: 2122 Finish Time: 2218 Examination Surface: Inside ; Outside Iv) Surface Condition: AS GROUND Lo Location: __Wo Location: Centerline of Weld Couplant: ULTRAGEL II Temp. Tool Mfg.: FISHER Serial No.: MCNDE 27219 Surface Temp.: 68 "F Cal. Report No.: CAL-06-297, CAL06-298, CAL06-299, CAL-06-300, CAL-06-301 Angle Used 40545 64T 6OLI-r j 70L Scanning dB 52] 45" 54- 55" 53" Indication(s): Yes ! 1 No A! Scan Coverage: Upstream (A Downstream f,] CW fA CCW Comments: FC 06-02' Lo = CL of nozzle adjacent to Circ. Weld Scanning Db's reduced from reference +14 to maintain 2:1 signal to noise ratio Results: Accept IV, Reject Info I'-! PSI Examination Percent Of Coverage Obtained > 90%: _0 0 -(PO .(P 0/p Reviewed Previous Data: No:xaminer Level Ill nature Date] Reviewe A Signat-"aton. Jav A. (-, A4111_l 5118/20061 A J 1//_j4 ?-..Batch 1Z.5 wi Ul-Let Down Cooler -Nozzle to Channel Body% Coverage Calculations Weld No. : Axial Scans Along Axis of Pipe = 100% of the Length x 45.2% of the Volume = 45.2%Along Radius of Pipe = 100% of the Length x 60.0% of the Volume = 60.0%Average = 45.2% + 60.0% / 2 = 52.6%Circ. Scans Along Axis of Pipe = 100% of the Length x 55.5% of the Volume = 55.5%Along Radius of Pipe = 100% of the Length x 81.7% of the Volume = 81.7%Average = 55.5% + 81.7% / 2 = 68.6%Total = (52.6 = 68.6 ) 1 2 = 60.6% Aggregate Coverage Inspector / Date: XTTIPýWY,&ez< -rb -eý-z Page I of Letdown Cooler Nozzle to Channel Body A I iA'CHM E N KI P A 6 E,ýg OF Weld No. : c3 '3?5q -3 Item No.: ___z f, Total Exam Area = 2.72 sq. in.Scale: P"= 1" jI -z5f a'?AL(r, ZOF 7 A I XAME N T-GAE-G< OF Letdown Cooler Noz"-fe to Channel Body Area Examined -Circ. Scans Weld No.; : J,~g-Item No. : Area not Examined = 0.81+ 0.40 = 1.21 sq. in.Area Examined = 2.72 -1.21 / 2.72 x 100 = 55.5%El5 A 450 Scale: 1" = 1" 450-?A kCE 3 oýý7 Letdown Cooler NozZle to Channel Area Examined -Axial Scans Body A I IA' CHMENT (2-PAgE 2 OF07 Weld No.

  • Y32' 9 -3 t:-3(, Item No.: ýSIA El Area not Examined = 1.49 sq. in.Area Examined = 2.72 -1.49 / 2.72 x 100 = 45.2%8-4 Scale: 1V =" 450 Zd-r-6 11S Letdo~n Cooler Nozzle to Channel Bod (Radius

=Weld No. *Item No. :-4A--Total Exam Area = 2.30 sq. in.Scale: !V = 1" Channel Body SI~~fAC- ~ ~ ~ ~ S jt-rc&I~~f (. Letdown Cooler Nozzle to C 1 1 annel Body ( Radius VieyHMENT Area Examined -Axial Scans P A 5E fF Weld No. : ?3-SZ-55q -3 Item No. : LIZ Area not Examined = 0.92 sq. in.= Area Examined = 2.30 -0.92 / 2.30 x 100 = 60.0%700 60O 4 5c Scale: i" = 'AIIACtýMC-yr -f-D TPALS (A,ni-ý Summary No.: Workscope: UT Calibration aamination Oconee 03.19.11.0056 Procedure: Procedure Rev.: Work Order No.: PDI-UT-2 AT IACHMENT Li.Outage No.: 03-25 Report No.: UT-10-657 Page: 1 of 6 01878531 Code: 1998/2000A Cat./ltem: B-J 1B9.11 Location: Rx Bldg.Drawing No.: ISI-OCN3-008

== Description:==

Safe End to Nozzle System ID: so Component ID: 3-PIA2-8 Size/Length;" N/A Thickness/Diameter: 2.33133.5/SS Limitations: Yes -See attached sheet Start Time: 1051 Finish Time: 1115 Instrument Settings Search Unit Cat. Time Date Axial Orientated Search Unit Serial No.: 014BLC Serial No.: 0105LJ Checks ,Calration $.n.l Sweep 1ound h Manufacturer: KRAUTKRAMER Manufacturer KBA I initial Cal. 1019 11/412010 Reffdetor Amplhifdq % Division Model: USN-60 SW Size: 0.50 Shape: Round Inter Cal. 10 Kftoh so 5.4 4.238 Delay: 7.5947 Range: 8.00 Freq,: 2.25 MHz Style: Comp -G Inter. Cal. 1050 1114/2010 M'tt CalfVel: .1268 Pulser: High Exam Angle: 45 # of Elements: Single inter. Cal 1 ... .Damping: 500 Reject: 0% Mode: Shear Final Cal. ___2_ 111412010 Rep. Rate: Autohigh Freq.: 2.25 Measured Angle: 43 Couplant * ,,_, Filter Fixed Mode: PE Wedge Style: MSWQC Cal. Batch: 09325 Circumferential Orientated Search Unit Voltage: 450 Other: Fullwave Type: ULTRAGEL II Calibration Signal I SWeep Ax. Gain (dB): 29.7 Circ. Gain (dB): 29.7 Search Unit Cable Mfg.: SONOT-hCH Rete;ctcr Ampiftude % Division Sound Pith 1 Screen Div. = .8 in. of Sound Path Type: RG -174 Exam Batch: 09325 See Axial .........Unearity Report No.: L-10-115 Length: 6' No. Conn.: 0.., 0 Type: ULTRAGEL II Calibration Block Scan Coverage Mfg.: SONOTECH Cal. Block No,: 40397 Upstream 2 Downstream[j Scan dB: 41.7 Reference Block ReferencetSimulator Block Thickness: 3.000 Da.: Flat CWR CCWF Scan dB: 41.7 Gain Signal P___________________ -edlNo:S7 Refletctor Amplitude % Division SudPt Cal. Blk. Temp.: 62 Temp. Tool: MCNDE40132 Exam Surface: O.D Type: ROMPAS 12.5 2- Radius 80 2.5 1.898 Comp. Temp.: 74 Temp. Tool: MCNDE40132 Surface Condition: As Ground Recordable lndication(sl: Yes[] No (if Yes, Ref. Attached Ultrasonic Indication Report.) " i' z Results: Accept [Q Reject [] Into 5 Comments: NIA Percent Of Coverage Obtained > 90%: No Reviewed Previous Dat Yes Exarniner Level ll Sgraturc Date Reviewer " natu. e " " Sull,~W.. Keith 1 10 Level It-N Signature Date Site RevieS nature Date Fos~s; Steven 111412010 Other Level NIA SgareDite ANtI teviow har Daye NIA Sumrnmary No.: Workcope: UT Calibration. amination O O 3.Be 1i. 35 03.819.11,00156 Procedure: Procedure Rev.: Work Order No.: PDI-UT-2 ATTACHMENTC6 PA6E_?L,0 af , Outage No.: 03-25 Report No.: UT-10-657 Page: 2 of 6 E 018785311 Code. 19i,;2000A Cat~iem: 1-1 /89.11 Location: Rx Bldg.Drawing No.: ISI-OCN3-008

== Description:==

Safe End to Nozzle System ID: 50'Component ID: 3-PIA2-8 SizeiLength: N/A Thickness/Diameter. 2.33133.61SS Limitations: Yes- See attached sheet Start Time: 1136 Finish Time: 1151 Instrument Settngs Search Unit Cal. T TIme Daw Axial Orientated Search Unit Serial No.: 014BLC Serial No.: SE0773 Checks Calibration S al Sweep S Manufacturer KRAUTKRAMER Manufacturer GE Initial Cal.1031 ________ Reflector Amplitude % Division Model: USN-60 SW Size: 0.50 Shape: Round InterCal totch 80 6.7 8.3 Delay: 9.5100 Range: 12.50 Freq.: 2.25 MHz Style: Comp -G Inter. Cal. l13S 11412010 M'I Calvel: .1232 Pulser: High Exam Angle: 70 # of Elements: Single I Inter. Cal.Damping: 500 Reject: 0% Mode: Shear -Final Cat. 112___ i `412_401 Rep. Rate: Autohigh Freq.: 2.25 Measured Angle: 71 Couplant/Filter, Fixed Mode: PE Wedge Style: MSWQC Cal. Batch. 09325 Circumferential Orientated Search Unit Voltage: 450 Other Fullwave Type: ULTRAGEL II Calibration Signal Sweep Ax. Gain (dB): 54.5 Circ. Gain (dB): tIA Search Unit Cable Mfg.: SONOTECH Reflector Amplitude % Divisicn IScund Path I Screen Div. = 1.25 in. of Sound Path Type: RG -174 .Exam Batch: 09325 .. A N/_Linearity Report No.: L-l0-115 Length: 6- No. Conn.: 0 Type: ULTRAGEL II Calibration Block Scan Coverage Mfg.: SONOTECH Cal. Block No.: 40397 Upstream WJ DownstreamE[ Scan dB: 60.5 Reference Block Reference/Simulator Block Thickness: 3.000 Dia.: Flat CW[] CCW[J Scan dB: lNlA SeilN. 0484 Gain Signal Sweep SudPt Cal._ _Temp.: -S2 Temp.Toot MCDE401eria No.: Suracn e d6 Reflector Amplitude % Division Calh k. Temp.: 062 Temp. Tool:' MC E40132t ExamCSurface: C ".Dan : Type: ROMPAS 1 I. Radiusi 8 1° .6 , Camnp. Temp.: 74 Temp. Tool: MCNOE40132 Surface Condition: As Ground 1.Recordable Indication(s): Yes E No &J (if Yes, Ref. Attached Ultrasonic Indication Report.)Results: Accept 0 Reject r Info n Comments: NIA Percent Of Coverage Obtained > 90%: No Reviewed Previous Dat. Yes Examiner L~evel ll- rSga eDaeRvwrX n t .-le Bull, W. Keith 111412010 -,Examirner Level It-N Signature Date Sit6 Sý3nalure Fors, Steven 1114J2040 Other Level NIA S. iga-ture Date ANII Review 5n 'e ate NIA W'-4rK P~~.a 1 ni Site/Unit Summary No.: Workscope: UT Calibration. ,amination PAlIAH ET i Outafe No.: 03-25 Report No.: UT-10-657 Page: 3 of 6 Oconee J 3 O3.89.11.0058 ISI Procedure: Procedure Rev.: Work Order No.: PDI-UT-2 01878631 Code: 199812000A Catllemr: B-J 1B9.11 Location: Rx Bldg.Drawing No.: ISI-OCN3-008

== Description:==

Safe End to Nozzle System ID: 50 Component ID: 3-PlA2-8 Size/Length: N/A Thickness/Diameter: 2.33/33.5/SS Limitations: Yes -See attached sheet Start Time: 1211 Finish Time: 1226 Instrument Settings Search Unit Cal. Time Da A SBaflh Unit Seral o.:O14LCSerial No.: 10-1204 Checks _____ Calibration Sifll sw SundPat Manufacturer: KRAUTKRAMER Manufacturer: RT Initial Cal. 1031 1114/2010 ReflecOr A division Model: USN-60 SW Size: 2(24x42)114L Shope: ReeL inter. Cal ..IDNoch so J 6.0 S.962 Delay: 111.2203 Range: 10.00 Freq: 2.0 MHz Style: WL2 Inter. Cal. 1210 1,111412010 M'tl Cal/Vel: .2121 Pulser: High Ex am Angle 60 _ Of Es: Dual Inter. Cal. -" "-"-Damping: 500 Reject: 0% Mode: Long.inal Cal.. 1258 1117120101 Rep. Rate: Autohigh Freq.: 2.0 Measured Angle: 60 Couplant ..... _Filter: Fixed Mode: Dual Wedge Style: Integral Cal. Batch: 09325 Circumferential Orientated Search Unit Voltage: 450 Other: Fullwave Type: ULTRAGEL II CalibrationI Signal Sweep Ax. Gain (dB): 42.2 Circ. Gain (dB): NIA Search Unit Cable Mfg.: SONOTECH Reflector Amplitude % Division koundlPath I Screen Div. = 1.0 in. of Sound Path Type: RG -174 Exam Batch: 09325 N. A _ _ _ I Linearity Report No.: L-10-115 Length: 6' No. Conn.: Type: ULTRAGEL II Calibration Block Scan Coverage Mfg,: SONOTECH Cal. Block No.: __40397 Upstream R] Downstream_] Scan dB: Reference Block ReferencelSimulator Block Thickness: 3.000 Dia.: Flat CW [lj CCW [J Scan dB: N IA G ain. Signal Sweep u Cal.___ B_________ -ep:6 ep o( CD412 Ea ufc:01 Serial No.: 04-8744 4111 Reflector Amplitude % Division Sound Patth Cal. 61k. Temp.: 6..1 Temp. Tool: MCNDE4O132 Exam Surface: 0.13 Type: ROMPAS 19.1 t2,:' Radiu~s ,,80 ,2 1.99 Camp, remp.: 74 Temp. Tool: MCNDE40132 Surface Condition: As Ground T R 1 2 1 2 , Recordable Indication(s): Yes E No [ (If Yes, Ref. Attached Ultrasonic Indication Repori.) _ _ _ _ _ _ _ _ _-Results: Accept 0 Reject 91 Info [3 Comments: N/A Percent Of Coverage Obtained > 90%: No Reviewed Pievius Data: Yes Bull, W. Keith " 111412010 " -,, Examiner Level l Y .Sinature ' Date Site Review A Date Foss, Steven 11141*210 Other LeVel N/A Signatue Data ANtIIReview ./,NA >' ~7 j 11 I I AI1ACHMENT 'C-DUKE POWER COMPANY I_ISI LIMITATION REPORT.... .AIem No: 03911.06 remarks.: ,NO SCAN SURFACE BEAM DIRECTION S LIMITEDSCAN F [1 2 0 1 i ! 2 E) cw ccw FROM L 0.0 to L 105,25" INCHES FROM WO CL to Beyond ANGLE: 50 Ex 45 Z 60 other 70" FROM 0 DEG to 360 DEG F5 NO SCAN SURFACE BEAM DIRECTION E3 LIMITED SCAN n1 22 l2 cw E ccw FROM L to L INCHES FROM WO to ANGLE: 50 5] 45 5 60 other FROM DEG to DEG 5 NO SCAN SURFACE BEAM DIRECTION _5 LIMITED SCAN n51 5 2 5]1 5] 2 []w Scow ___FROM L to L INCHES FROM WO to I ANGLE: 5 0 5 45 5 60 other FROM DEG to DEG El NO SCAN SURFACE BEAM DIRECTION 5 LIMITED SCAN 5 1 5 2 E) 1 2 5 Cw 5 ccw UT-10-657 FROM L to L INCHES FROM WO to Sketch(s) attached ANGLE: .E 0 ] 45 5 60 other _ FROM DE-GtoQ DEC [] yes 5 No Prepared By: Steve Foss 5 Level: Date: 11104o10 5t_ 4 "-"2-Reviewed By: D,,e: ,,,/e .Dat e:....4 k. - Supplemental Report AT IACHMENIT 2-PASE OF q-2 Report No.: UT-10-657 Page: 5 of a Summary No.: O3.B9.11.0056 EXaminer Bull, W. Kelth Level: I1-14 Exaitner: Foss, Steven Level: N/-N Other: NIA Level: NIA Site Review: .ANII Review: Date Date: Comments: 4 ýSketch or Photo: 5ARC e2M rA\ c4 -51 F Determination of Percent Coverage for LUT Examinations -Pipe.JI.-- r. tunhl /Summary No.: 03.B9.11.0056 Woilccope: 181 Procedure: Procedure Rev.: Work Order No.: r"uI"U I-Z E 01878531 UI R utage No,: 03-26 sport No.: UT-I 0467 Page: 6 of 6 Scan1 _ % LenglthX %volumeoffengthl0OlOo .%_totalfor Sean Scan 2 % Length X % volume of length 1100 -%_totalfor $a 2 Scan3 100.000 % LengthX 50.000 %volumeoflength 1it'O10 M000 % total for fcan 3 San4. 100.000 % Length X 80.000

  • volume of length Ic00,, 60.000 % total forSca 4 Add totals and divide by # acanm z%totalfor45deg Other dm!. -0 (to be used for supplemental scans)The data to be Bated below is for coverage that was not obtained with the 45 dog scans.Scan 1 100.000 % Length X 0.000 Scan 2 100.000 % Length X 50.000 San 3 % Length X Scan 4 % Length X% volume of length 11001 0.000 % total for Scan 1% volume of length 100 a 60.000 %total for 8can 2% volume oflenigth 1100 a.......%

total for Scan 3% volume of length /100 a % total for Scan 4 Add totala for each scan required and divide by # of scans to determine: 14k Total for complete exam Site Field Supervisow. Sil FildSup~er~ &e"~6~.~ '~~Date;:LV Site/Unit: Summary No.: Workscope: UT CallbraflonILý-aminaflon Oconee 1 3 03.B9.11.0056 IS'Procedure: Procedure Rev.: Work Order No.: NDE-830 I 01878531 A TIACHME N I P AI 6 v~l E...5Or9i Outage No.: 03-25 Report No.: UT-10-646 Page: 1 of 4 Code: 199812000A Cat./Item: B-J 1B9.11 Location: Rx Bldg.Drawing No.; ISI-OCN3-608

== Description:==

Safe End to Nozzle System ID: 50 Component ID: 3-PIA2-8 SlzeJLength: NIA ThicknesslDiameter 2.33133.51SS Limitations: Yes -See attached sheets Start Time: 1003 Finish Time: 1033 Instrument Settings Search Unit Cal. Time I Date Axial Orientated Search Unit Serial No.: OOWHDK Serial No.: 03-789 Checks_ _ C"ribricn s s c Path Manufacturer. KRAUTKRAMER Manufacturer: RTD Initial Cal. 084 111412010 e C0or i nw r % wIepsio n... ell%!of Amplituide % Civision Model: USN-60 Sie: Shape: Rect Inter. Cal. _ 314"T I'tt 80 4.8 328 Delay: 16,7506 Range: 7.0 0. MHz Style: TRLI Inter. Cal. 0959 111412010 M'tl CalVel: .2600 Pulser:. High Ex am n ie: 60L "'o f Elements: Du al Inter. Cal. ;_ _ _ .. ..Damping: 1K Reject: 0% mode: Final Cal. 132 111412010 Rep. Rate: Aulohigh Freq.: 1.0 Measured Angle: 60 Couplant :___... .__...__... Filter: Fixed Mode: Dual Wedge Style: Integral Cal. Batch: 09325 Circumtferential Orientated Senrch Unit Voltage: Fixed Other: Fulhwave Type: ULTRAGEL II iibtion Si .Swep Ax. Gain (dB): 70.1 Circ. Gain (dB): 71.2 Search Un0t Cable Mtg.: .SOOTECH Reflecr Ampltde % Divsind' ath 1 Screen Div- = .7 in. of Sound Path Type: RG -174 Exam Batch: 09325 314 T Hole so 5.2 3.59 Linearity Report No.: L-10-109 Length: 6' No. Conn.: 0 Type: ULTRAGEL II Calibration Block Scan Coverage Mfg.: SONOTECH Cal. Block No.: .50214 Upstream E] Downstream ] Scan dB: 72.S Reference Block I RfemencSimuatitr Block Thickness: 2.4"4 Dia.: Flat' CW R CCWJ Scan dB: 72.6 IGam signal Sweep Serial No.: 04-8739 1 dB Re,"ector Amplitiud % D Slurd lh Cal. 81k. Temp.: 70 Temp. Tool: MCNDE40132 Exam Surface., O.D. Tye asPA I 30°2% D 2i adisB( 28 11 Comp. Temp.: 72 Temp. Tool: MCNDE40132 Surface Condition: As Ground I ...2.00 Recordable Indication(s): Yes El No [] (if Yes, Ref. Attached Uitrasonic Indication Report.)Results: Accept El Reject Ov Info E1 Comments: NIA Percent Of Coverage Obtained > 90%: N/A Revie Previous Data: _ _ _xvnaelY Reviewer se -late Henrdrickson, Matthew 1142010 OtLer Level tI' " Date Site Review Sinal re Dat Griabel, David M. 1114/2DI0 Other Levet NIA sigrnaturd Dale ANII Review Sisnature Datl-SitelUnit: Summary No.: Workscope: UT CafibrationIL--amination Oconee / 3 03.B9.11.0056 Procedure-Procedure Rev.: Work Order No.: NOE-830 I 01878531 T At HME ti T Outage No.: 03-25 Repor" No.: UT-10-646 Page: 2 of 4 Code: 199812000A Cat./item: B-J 159.11 Location: Rx Bldg.Drawing No.: ISI-OCN3-408 Description, Safe End to Nozzle System ID: 50 Component ID: 3-PIA2-8 Size/Length: N/A Thickness/Diameter: 2.33133.5/SS Limitalions: Yes -See attached sheets Start Time: 1035 Finish Time: 1106 Instrument Settings Search Unit f Cal. Time Date Serial No-: 00WHDK Serial No.: 90-371 Checks _ __ " Manufacturer. KRAUTKRAMER Manufacturer. RTD Initial 0461 11142010 Model: USN-60 Sizem Z(10x18) Shape. 9 Inter. Cal. _Delay: 10.6653 Range: 5.00 Freq... 2.0"MHz Style: TRLA Inter. Cal. 1034 111412010. M'tJ CaWe,: .2392 P,,lsec: High tkarnAngle: 70 Ie~n IS4 14z Damping: 1 K Reject: 0% ModFial Cal. o1534 Rep. Rate: Autohigh Freq.: 2.0 Measured Angle: 70 Couplant Filter: Fixed Mode: Dual Wedge Style: Integral Cal. Batch: 09325 Voltage: Fixed Other:. Fullwave Type: ULTRAGEL II Ax. Gain (dB): 80.0 Circ. Gain (dB): NIA Search Unit Cable Mfg.: SONOTECH I Screen Div.= _.5 in. of Sound Path Type: RG -174 E 09323 Linearity Report No.: L-10-109 Length: 6' No. Conn.: T Type: ILTRAGEL II1 Calibration Block Scan Coverage mfg.: SONOTECH Cal. Block No.: 50214 Upstream D Downstream-Scan dB: 80.0 Ref Block Thickness: 2.464 Dia.: Flat CWRJ CCW&5 Scan dB: 500 Serial No.: 048739 Cal. Blk. Temp.: 70 Temp. Tool: MCNDE40132 Exam Surface: O.0. Type: ROMPAS Camp. Temp.: 72 Temp. Tool: MCNDE40132 Surface Condition: As Ground Recordable Indicationfs): Yes No [ (if Yes, Ref. Attached Ultrasonic Indication Report.)Results: Accept C] Reject W Info [] Comments: Unab Percent Of Coverage Obtained > 90%: 1/ , .1NA R,, e~ed Previous Data: Yes Axial Orientated Search Unit Calibration Signal Sweep Sound Path Reflector Amplitude % Division 114T Hole s0 3.8 1.89 Circumferential Orientated Search Unit Calibration Signal Sweep Reflector Amplitude % Division Sound Path NIA t _Reference/Simulator Block Gain I Signal LSweep ý--O ....dBI Reflector Amplitude % Division Sound Pat 36.5 ,12' Radiusl so 4.00 7.00 le to discern I14T Hole In circ. direction. Ai7A~Th.T DUKE POWER COMPANY ISI LIMITATION REPORT Component/Weld ID: 3-P1A2-8 Item No: 03.19.11.0056 ..remarks:[ NO SCAN SURFACE BEAM DIRECTION Procedure allows scanning from El LIMITED SCAN El 1 [ 2 Z I Dl 2 0l Cw F1 ccw cast sideonly.FROM L N/A to L N/A INCHES FROM WO CL to Beyond _ _ _ ___, ANGLE: El 0 El 45 Z 60 other 70 FROM 0 DEG to 360 DEG F] NO SCAN SURFACE BEAM DIRECTION El LIMITED SCAN El 1 1] 2 [1 I El 2 nl cw 5 Ccw FROM L to L INCHES FROM WO to ........ ..ANGLE: nl 0 E] 45 El 60 other___ FROM _ DEG to _ DEC El NO SCAN SURFACE BEAM DIRECTION El LIMITED SCAN El I El 2 El 1 El 2 C) cw 5 cow ,FROM L to L INCHES FROM WO to ___ANGLE: El 0 El 45 El 60 other FROM DEG to CDE El NO SCAN El LIMITED SCAN SURFACE 1 02 BEAM DIRECTION El IE 2 5 ow [I Cow UT-1 0-646 FROM L to L.ANGLE: 5]0 0 45 0'60 / 0 INCHES FROM WO:to DEG to__DEG I Sketch(s) attached ElNo Z yes 4 Date: Supplemental Report Al ACHMENT,ý- Report No.: UT-1 0-646 Page: 4 of 4 Summary No.: 03.B9.11.0056 Examiner: Hendrickson, Matthew vel: 11-N Examiner. Griebel, David M. Level: Other: NIA -Level: NIA Reviewer: Site Review.ANI[ Review: Al/I;Date.Date: Comments: Best effort exam using 6O*RL & 70*RL per NOE 530 for upper 2[3 area of interest.V'1/2'3 1 ooýý,::74w Sketch or Photo: I, I I I I I-J I Vi--524'4 -Site/Unit: Oconee Summary No.: Workscope: UT CalibrationIL-ami nation 1 3 03.B9.11,0060 Procedure: Procedure Rev.: Work Order No.: P131-UT-2 E A T I Report No.: UT-1 0-640 Page: I of 6 IS'01878761 Code. 199812000A Catlitem: B-J 1B9.11 Location: Rx Bldg.Drawing No.: ISI-OCN3-009

== Description:==

Safe End to Nozzle System ID: 50 Component ID: 3-P6-8 "Size/Length; .WA ThicknesslDiameter: 2.33133.5ISS Limitations: Yes -See attached sheet Start Time: 1210 Finish Time: 1250 Instrument Settings Search Unit cal. " Time Date " Axial Orientated Search Unit Serial No.: 0114738 Serial No.: 01F10K Checks Sweep Manufacturer KRAUTKRAMER. Manufacturer KBA Initial Cal. 1013 1114/2010 Reflector Amplitude % Division Model: USN-60 SW Size: .50 Shape: Round Irner Cal. 144 1114. 21.0 ID Notch 80 6.7 4,157 Delay: 5.7966 Range: 7.001 Freq.: 2.25 MHz Style: Comp -G Inter. Cal.Mil CalNel: 0.1234 Pulser: Square Exam Angle: 45 # of Elements: Single Inter. Cal. 1248 1114/2010 Damping: 500 Reject: 0% Mode: Shear I Final Cal., 1312 11/412010 !Rep. Rate: Autohlgh Freq.: 2.25 Measured Angle: 4;5 Couplant '__Filter: Fixed MOde: PE Wedge Style: MSWQC Cal. Batch: 09325 Circumferential Orientated Search Unit Voltage: 450 Other Fullwave Type:, ULTRAGEL II Calibration Signal S .weep SudPt Ax. Gain (dB): NIA Circ. Gain (dB): 25.6 Search Unit Cable Mfg.: SONOTECH Reflector Amplitude % DisionS I Screen Div. = .70 in. of Sound Path Type: RG- 174 .Exam Batch: 093255.7 4.157 Linearity Report No.: L-10-110 Length: 6- No. Conn.: -Type: ULtRAGEL II Calibration Block Scan Coverage Mfg.: SONOTECH t _. ..... .Cal. Block No.: 40397 Upstream [J Downstream[] Scan dB: N/A Reference Block ReferencelSimulator Block Thickness: 3.000 Dia.: Flat CWPI CCWRJ Scan dB: 36.8 SerialGain Signal Sweep Sound Pth_______SralN.-484-B Relco mltd % :Division Son at Cal. Blk. Temp.: TO Temp. Tool: MCNDE40132 Exam Surface: 0.0 Type: ROMPAS15 d 2 Refausl 60Am.iud 2,023 Comp. Temp.: 75 Temp. Tool: MCNDE40132 Surface Condition: As Ground Recordable Indication(s): Yes [J No [ (If Yes, Ref. Attached Ultrasonic Indication Report.)Results: Accept fl Reject [ Info [7] Comments: NIA Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes-examiner Level ni- Signature Date ReviewerS. njlur a Stauffer. Lester, E 111412010 N.:Peterson, Drew ...... .... Oeher-LevI A .... Signature Dote ANil Review NIA I",W ýf 0 9F Shte/Unit: Summary No.: Woftcopew UT Calibration/L.4amination Oconee / 3 03.Bg.11.0060 ISl Procedure: Procedure Rev.: Work Order No.: PDIDUT-2 E 01878761 Outage No.: 03-25 Report No.: UT-10-640 Page: 2 of 6 Code: Drawing No.: System ID: 60 Component ID: 3-P011-3 Limitations: Yes -See 199812000A CatJitem: 1-J IB9.11

Description:

Safe End to Nozzle Location: Rx Bldg.ISi-OCN3-009 attached sheet Size;Length: 'NIA Start Time: 1210 Thickness/Diameter: 2.33133.5/SS Finish Time: 1250 Instrument Settings Serial No.: 014738 Seria N Manufacturer. KRAUTKRAMER Manufs Model: USN-60 SW Size: Delay: 7.8484 Range: 12.00 Freq,: M'tI Cal/Vel: 0.1235 Pulser Square Exam A Damping: 500 Reject: 0% Mode: Rep. Rate: Autohigh Freq.: 2.25 Measuro Filter: Fixed Mode: PE Wedge Voltage: 450 Other: Fulhwave Ax. Gain (dB): 42.3 Circ. Gain (dB): 42.3 1 Screen Div. = 1.20 in. of Sound Path Type: Linearity Report No.: L-10-110 Length: Calibration Block Search Unit o.: ..SE0355 cturer: KBA.S0 Shape: -Round 2.25,MHz Style:: Comp-G ngfe: .60 # of Elements: Single Shear ed Angle: 60 Style: MSWQC Search Unit Cable RG.- 174.IFinalCatl. 1 131 1114120101 Couplant Cal. Batch: .09325 Type: .ULTRAGEL it Mfg.: SONOTECH Exam Batch: 09325 Type: ULTRAGEL It Mfg.: SONOTECH Circumferential Orientated Search Unit 6. No. Conn.: 0 Scan Coverage;slibr-ton 1 Signal we Reflector Amplitude % Division Sound Path See Axial ____ ___ ___Reference/Simulator Block Gain Signal Sweep dB I Reflector Amplitude %I Division Sound Path 15 12" Radius 97 I 1.7 I 2.019 Cal. Block No.: 40397 Upstream El Downstream 2- Scan dB: 48.3 Reference Block Thickness: 3.000 Cia.: Flat CW ] CCWR Scan dB: 48.3 Serial No.: 044743 Cal. Blk. Temp.: 70 Temp. Tool: MCNDE40132 Exam Surface: O.D Type: ROMPAS Comp. Temp.: 75 Temp. Tool: MCNDE40132 Surface Condition: As Ground Recordable Indication(s): Yes [-- No MV (If Yes, Ref. Attached Ultrasonic Indication Report.)Results: Accept 0 Reject [] Info C] Comments: NIA Percent Of Coverage Obtained > 90%: No Previous Data: Yes

Summary No.: Warkscope:

UIT CalibrationIL-amination Oconee 1/ 3 03.B9.11.0060 Procedure: Procedure Rev.: Work Order No.: ATTACHMENT " PoI-UT-2 A6E r Outage No.: 03-25 E Report No.: UT-10-640 01878161 Page: 3 of 6 Code: 1998/2000A B-J 1B9.11 Location: Rx Bldg.Drawing No.: iSI-OCN3-009

== Description:==

Safe End to Nozzle System ID: 50 Component ID: 3-PIBI-8 SizeiLength:. NIA Thickness/Diameter: 2.33133.SISS Limitations: Yes -See attached sheets Start Time: 1210 Finish Time: 1250 Instrument Settings Search Unit Cal. Time Date I Axial Orientated Search Unit Serial No.: 014738 Serial No.: 10-1203 Checks Calibration Signal Sweep Sound Path Manufacturer: KRAUTKRAMER Manufacturer. RTID Initial Cal. 1034 111412010 Reflector Amplitude % Division Model: USN-60 SW Size: 2(24x42)114L Shape: Rect. Inter. Cal. 1126 11142010 Not 80 6.7 5.737 MTl Cal/Vel: 0.2188 Pulser: Square Exam Angle: 60 # of Elements: Dual Inter. Cal. 1253 111412010 Delay: 11.6894 "Range: 10.00 Freq.: 2.0 MHz Style: TRLA Inter., Cal. ,,__ ___________ ___Damping: 500 Reject: 0% Mode: Long. -Final Cal. 1310 Rep. Rate: Autohigh Freq.: 2.0 Measured Angle: 60 Couplant _Fier. Fixed Mode: Dual Wedge Style: Integral Cal. Batch: 09325 Circumferential Orientated Search Unit Voltage: 450 Other: Fullwave Type: ULTRAGEL n Calibration Signal Sweep Sodila Ax. Gain (dB): 46.9 Circ. Gain (dB): N/A Search Unit Cable Mfg.: SONOTECH Reflector I Amplitude % Division P I Screen Div. = 1.0 in. of Sound Path Type: RG -174 Exam Batch: 09325 WA __Linearity Report No.: L-10-110 Length: 6' No. Conn.: -Type: ULTRAGEL 11 l_ _ I Calibration Block Scan Coverage Mfg.: SONOTECH Cal. Block No.: 40397 Upstream [] Downstreamr Scan dB: 57.4 Reference Block ReferencelSimulator Block Thickness: 3.000 D1a.: Flat CWJ COWE Scan dB: NIA Gain Signal Sweep Sound Path din Reflector Amplitude% Division Cal. Blk. Temp.: 70 Temp. Tool: MCNDE40132 Exam Surface: O.D Type: ROMPAS 40 2 Radiusj 88 1.971 Comp. Temp.: 75 Temp. Tool: MCNDE40132 Surface Condition: As Ground Recordable Indication(s): Yes No [] (if Yes, Ref. Attached Ultrasonic Indication Report,)Results: Accept Q Reject [ Info [L Comments: NIA Percent Of Coverage Obtained > 90%: No RevFewed'0,vlous Daft' Yes Examlner evel ll-N S Date Rewer Stauffer, Lester, E. 1 V412010 Examiner L-1e 1ll-N nurOe Site Review ,-haleDe"Peterson, Drew S. /4/201 Other Level NIA Sigwature Dale ANII RevtewvXe Acl l N/A A, Y PAGE L-1 DF c DUKE POWER COMPANY IST LIMITATION REPORT LIMITED SCAN" ...... ..CormponentfWeld'11: 34-9I34-8 Item No: 03.19.11.0060 remarks:[ NO SCAN SURFACE BEAM DIRECTION No scan due tocast stainless[1 LIMITEDSCAN 0 [ 2 LI1 MI 2 cv ccw, pumpcasing. FROM L N/A to L NWA INCHES FROM WO CL to aBeyond _ANGLE: C3 0 10 45 0, 60 other 60RL FROM 0 DEG to 360 ,DEG[1 NO SCAN SURFACE BEAM DIRECTION I LIMITED SCAN [1 [] 2 L] 1 E] 2. _ _ CM_________l_ FROM L to L INCHES FROM WO to _.ANGLE: [.0 [] 45 L0 60 other FROM -DEG to DEG LI NO SCAN SURFACE BEAM DIRECTION[E LIMITED SCAN [I I [E 2 El I Ll 2 E] cw El cow FROM L to LINCHES FROM WO to .... _ANGLE: L] 0 L] 45 [060 other FROM O DEG to- _ DEG[1NO SCAN SURFACE BEAM DIRECTION[1 LIMITED SCAN [ 1 [] 2 [] 1 [1 2 [] eW LI CGw UT-10-640 FROM L to L INCHES FROM WO to iSketch(s) attached ANGLE: [1 0 0 45 E] 60 other FROM DEGto DE ye [ No Prepared By: Lester StaiJ<L> L -Level: ti ai:w... of fRevie~we-d By: ~ ., ~l:~ Da I e A I IA C HMCNLf P A E[ ai fF Supplemental Report Report No.: UT-10-640 Page: 5 of -e,2 Summary No.: 03.B9,11.0060 Examiner: Stauffer, Lester, E.Examiner: Peterson; DrewA, Other: N/A ow 111-N Level: IlI-N Level: H/A Reviewer: Site Review: ANII Review: Me j -Date: Date: Comments: 4S Z,~4Z~Comments: Li :5 (ýZz Sketch or Photo: 40OPL-ffAVAN rI_ 0 ---) -cc(p-< ctJ~ i -M~t c -, 5 -r A 4iw .FIZoA,,? 9 2Ac -)A-Vr to AS7-f ýC-A;-t -ýttt, E v Duk Determination of Percent Coverage for UT Examinations -Pipe x Site/Unit: Oconee / 3 Summary No.: 03.19.11.0060 Workscope: IS1 Procedure: Procedure Rev.: Work Order No.: PDI.UT-2 E 01878761 Outage No.: 03-25 Report No.: UT-10-640 Page: 6 of 6'I:, 45 den Scan 1 Scan 2 Scan 3 Scan 4% Length X % volume of length 1100 =% Length X % volume of length /100 =100.000 % Length X 50,000 % volume of length / 100 =100.000 % Length X 50.000 % volume of length /100 =* total for Scan 1% total for Scan 2 50.000 % total for Scan 3 50.000 % total for Scan 4 Add totals and divide by# scans = 50.000 % total for 45 dog Other deg -60 (to be used for supplemental scans)The data to be listed below is for coverage that was not obtained with the 45 deg scans.Scan I Scan 2 Scan 3 Scan 4 0.000 % Length X 0.000 % volume of length / 100 =100,000 % Length X 50.000 % volume of length / 100 =% Length X % volume of length / 100 =% Length X % volume of length i 100 =0.000 % total for Scan 1 50.000 % total for Scan 2% total for Scan 3% total for Scan 4 Percent complete coverage Add totals for each scan required and divide by # of scans to determine; 37.500 % Total for complete exam Site Field Supervisor: Sie ~ed uprvsr:Dae:i'F Date: J-X, Summary No.: Workscope: UT Calibration/L,-amin~ Oconee 1I.03.B9.l1.0060 Procedure: Procedure Rev.: Work Order No.: ation ATTACHMENT, NDE-830 PA&SE O F 0-3 Outage No.: 03-25 Report No.: UT-10-647 01878761 Page: I of 4 Ist Code: 1998d2000A Cat./item: B-.J 19.11 Location: Rx Bldg.Drawing No.: ISI-OCN3-009

== Description:==

Safe End to Nozz le System ID: 50 Component ID: 3-PlB1-8 Size/Length: NA Thickness/Diameter: 2.33133.5/SS Limitations: Yes -See attached sheets Start Time: 1332 Finish Time: 1401 Instrument Settings Search Unit -' .... .. ; .......Serial No,: OOWHDK Serial No.: 03-789 Checks I C; 1 t t z ' i C a lib r a tio n t S ig n a l S,, o u r -,o , p a th Manufacturer: KRAUTKRAMER Manufacturer: RTD IitialCal. -111412010 Res-ctr '.Ap&i'uIe I vs DivOkn Model. ..USk-60 Size: 2(20x,34) Shape. Red. Inter. Cal. X 34 T Hole A0.8 3-28__Delay: 16.7506 Range: 7.0 Freq.: 1.0 MHz Style: TR1 Inter. Cal. 1331 1,114,120106 M11 CaWel: .2600 Pulser: High Exam Angle: 6OL # of Elements: Dual Inter Cal t_____2_Damping: 1K Reject: 0% Mode: Long '1532 1142010 Rep. Rate: Autohigh Freq.: 1.0 Measured Angle: 60 Couplant __.... .Filter. Fixed Mode: Dual Wedge Style: Integral Cal. Batch: 09325 Circumferential Orientated Search Unit Voltage: Fixed Other: Fuliwave Type: ULTRAGEL II Calibration signal Sw~erp Ax. Gain (dB): 70.1 Circ. Gain (dB): 71.2 Search Unit Cable Mfg,: SONOTTECh R-f'l&oTr % OD:h'on Sound Path I Screen Div. = .7 in. of Sound Path Type: RG- 174 Exam Batch: 09325 314THole J 80 5.2 3.59 Linearity Report No.: L-10-109 Length: 6- No. Conn.: 0 Type: ULTRAGEL II Calibration Block Scan Coverage Mfg.: .SONOTECH_ Cal. Block No.: 50214 Upstream[EI Scan dB: 72.6 Reference Slock ReferencelSimulator Block Thickness: 2.464 Dia.: Flat CWRJ CCWW Scan dB: 72.6 Gain SignN7. a.le% p Sound Path Cal. B1k. Temp.: 70 Temp. Tool: MCNDE40132 Exam Surface: 0.0. Seil o: i Reflevar Amptlitude % Divia~on Type: ROMPAS 302 -' Radius so 2.s 2.00 Comp. Temp.: 72 Temp. Tool: MCNDE40132 Surface Condition: As Ground Recordable Indication(s): Yes E] No R] (If Yes, Ref. Attached Ultrasonic Indication Report.)Results: Accept f, Reject [] Info Comments: NIA Percent Of Coverage Obtained > 90%: NIA Reviewed Previous Data: Yes Examine'r Level fl is Date Reviewer nature tI Griebl, David M ./. n' ,,,,,- ..... .Examiner Level .Se Review Signalure Date" Hendrcs, Matthew Dl Other Le-vel NIA 0oolr ate ANIl Review Sintr a!NIA j 0J t D Site/Unit: Summary No.: Workscope: UT CalibrationlL.am iination Oconee 1 3 03.B9.11.0060 Is'Procedure: Procedure Rev.: Work Order No.: NDE-830 I 01878761 TACflMENT P0.-s E Ou7D ge No,: 03-25 Report No.: UT-I 0-647 Page: 2 of 4 Code: 1998/2000A CatJltem: B-J IB9.11 Location: Rx Bldg.Drawing No.: ISI-OCN3.09

== Description:==

Safe End to Nozzle System ID: 50 Component ID: 3-PIBI-8 Size/Length: N/A Thickness/Diameter. 2.33/33.5/SS Limitations: Yes -See attached sheets Start Time: 1403 Finish Time: 1435 i nstrument Seitings Search Unit T ' ... AxIl Orientated Search Unit Serial No.: G0WHDK Serial No.: 90-371 Checks ________ Calibration signat I OSwP Soud, Path Manufacturer: KRAUTKRAMER Manufacturer RTO Initial Cal. 0845 1114/2010' Refle"' or Amniti;de Y Division I Model: USN-60 Size; 2Cl,,x8,, s .e: ec Inter..Cadl. obI Hole s0 3.8 1 1.89 Delay: 10.6653 Range: 5.00 Freq.. 2.0 MHz tyle: TRLA Inter.Cal. 1402$ 11141201a M'tl Calvel: .2392 Pulser: High Exam Aagle: 70 X of Elemenfts Dual 1Inter. Cal,,__4______ _________Damping: 1K Reject: 0% Mode: Long -Fina Cal. 1534, 11142010 Rep. Rate: Autohigh Freq.: 2.0 Measured Angle: 70 _Couplant ..... ...... -_ .. .. ....Filter: Fixed Mode: Dual Wedge Style: Integral Cal. Batch: 09325 Circumferential Orientated Search Unit Voltage: Fixed Other: Fullwave Type: ULTRAGEL II1 Calibration Signal i Swe ep Ax. Gain (UB): 50.0 Circ. Gain (dB): NIA Search Unit Cable Mfg.: SONOTECH Reflector Amplitude

m. Division u....d Pah 1 Screen Div. = .5 in, of Sound Path Type: RG -174 Exam Batch: 09325 NIA ___ ', ..........

.Linearity Report No.: Length: 6' No. Conn.: 0 Type: ULTRAGEL I Leaiyeoto:L-10-109 -Tp: UTAE~Calibration Block Scan Coverage Mfg.: SONOTECH.t Cal. Block No.: 50214 Upstream r-J OownstreamS Scan dB: 80.0 Reference Block Reference/Simulator Block Thickness: 2.464 Dia.: Flat CW- CCWRJ Scan dB: 50.0 Serial No.: 04-i1739 Gain Sweep SoundPath Cal. Blk. Temp.: 70 Temp. Tool: MCNDE40132 Exam Surface: OD. Type: ROMPAS 36.6 2' Radius 80 i 4.00 7.00 Comp. Temp.: 72 Temp. Tool: MCNDE40i32. Surface Condition: As Ground Recordable Indication(s): Yes M No [] (if Yes, Ref. Attached Ultrasonic Indication Report.)Results: Accept 0] Reject W] Info 0 Comments: Unable to discern 114T Hole in circ. direction. Percent Of Coverage Obtained > 90%: NiA Reviewed Previous Data: Yes ,,,xaminer Leve -ignatue Date evie....-.at S DateýGmrebel, David M. 1111412010 9-a Ex e Lev jI.- ;.. Date S.. e Revie: Slnature Diate Other Level -si/gnature-D N/AI! C/ t A~DUKE POWER COMPANY ISI1 LIMTATION REPORT ... ...Component/Weld ID: 3-PlBI-8 Item No: O 3.139.11.0060 remarksntoSCAN SURFACE BEAM DIRECTION Procedure allows scannin g from SLIMITED SCAN 1 [I 2 0 1 02 S cw c cw castside only.FROM L NIA to L N/A INCHES FROM WO CL to Beyond ANGLE: [1 0 E] 45 0 60 other 70 FROM 0 DEG to 360 DEG[1 NO SCAN SURFACE BEAM DIRECTION[1 LIMITED SCAN ] I [D 2 [] 1 [] 2 n cw Eccw FROM L to L INCHES FROM WO to ANGLE: E] 0 [] 45 5 60 -other FROM DEG to DEG[1 NO SCAN SURFACE BEAM DIRECTION 0 LIMITED SCAN [1 [1 2 [11 n 2 [ cw [] ccw FROM L to L INCHES FROM WO to ANGLE: [1 0 E 45 [1 60 other FROM DEG to DEG[1 NO SCAN SURFACE BEAM DIRECTION[1LIMITED SCAN ] 1 [1 2 [1 [ 2 [ cw[ cCw UT-10-647 FROM L to L INCHES FROM WO to Sketch(s) attached ANGLE: [1T0 5] 45 [] 60 other FROM to DEG 0 yes [1 No Pedvid Griebel /§ ,Level: Dte:. S104/i0 Sheet 3 of 4* ~o Le.. , .. ... ..ReviwedBy:Date:- yAhorized Ihspector:., Date: r-- (,-- -ýý\ n 7,_D iz)Lr Supplemental Report AIIACHMENIC Report No.: UT-10-647 Page: 4 of 4 Summary No.: 03,99.l1.0060 Examiner: GrietbeI, David.M. tlevef: Il-N Examiner: Henaricksont MattNer a eeel; I n Other: NIA Levef: NIA Reviewer: Site Review: ANII Review: Date: _I-.9 Date: Date:It._io -to 114 -Comments: Best effort exam using 60*Rt. & T 0'RL per NDE 830 for upper 213 area of Interest.I I I. I I *),\ I1 /~52 PASEK/j- 0-Site/Unit: Summary No.: Wo'kscope: UT Calibration/ .amination Oconee / 3 03.89.11.0064 'IS Procedure: Procedure Rev.: Wor3k O.'er No.: POI-UT-2 E Outage No.: 03-25 Report No.: UT-10-645 Page: 1 of 6 Code: 1998t2000A Cat/Item; B-J I18.11 Location: Rx Bldg.Drawing No.: ISI-OCN3-010

== Description:==

Safe End to Nozzle System ID: so Component ID: 3-PIB2-8 Size/Length: N/A Thickness/Diameter: 2.33/33.5tSS Limitations: Yes -See attached sheet Start T me: 1127 Finish Time: 1200 Inument Settintgs Search UnitI Cal. ITime Date Axial Orientated Search Unit Serial No.: 014738 Serial No.: 01F10K Checks %Calibration Sianl Manufacturer: KRAUTKRAMER Manufacturer: KBA Initial Cal. _11013 11/412010 Reflector Ampitude % DVision Model: USN-60 SW Size: .50 Shape- Round Inter. Cal. '1 1144 111412010 lDNotch 80 5.7 J 4.157 Delay: 5.7966 Range: 7.00- Freq.: 2.25 MHz Style: Campo-0 Ioter. Cal.. _...._ _ne,.C_. _ _, _ _ _ _ _ _ _ _ _ -I J ......M'] Cal/Vel: 0.1234 Pulsr Square Exam Angle: 45 # of Elements: Single Inter. Cal. 1`14M20101 Damping: o500 Rejed: 0% Mode: Shear FinaI Cal. 13121 11/4120101 3 Rep. Rate: Autohlgh Fmq.: 2.25 Measured Angle: 46 Couplant I 1 1 Filter- Fixed Mode: PE Wedge Style: MSWQC Cal. Batch: 09325 Circumferential Orientated Search Unit Voltage:....450 .Other Fullwave Type: ULTRAGEL II Calibration Signal Sweep SondPah Ax. Gain (dB): N/A Circ. Gain (dB): 25.6 Search Unit Cable Mf,: SONOTECH Reflector Amplitude % Division jSnd 1 Screen Div. = .70 in. of Sound Path Type: RG -174 Exam Batch: 09325 10 Notch 80 5.7 4.157 Linearity Report No.: L-10-110 Length: 6' No. Conn.: 0 Type: ULTRAGEL If Calibration Block Scan Coverage Mfg.: SONOTECH Cal. Block No.: 40397 Upstream ] DownstreamE] Scan dB: N/A Reference Block Referenceitimulator Slok, Thickness: 3.000 Dia.: Flat CW 0V CCW2 Scan dB: 36d. Serial No.: 04-8743 Di Sign ivision S CaL Blk. Temp.: 70 Temp. Tool: -MCNOE4tII32 Exam Surface: 0.03 Type: RO1WPAS Is 2" Radius so. I2A8 Z023.Comp. Temp.: 75 Temp. Tool: MCNOE4Oi3Z Surface Condition: As Ground Recordable Indlcation(s): Yes 5 No R] (If Yes, Ref. Attached Ultrasonic Indication Report.) .Results: Accept [] Reject .] Info 11 Comments: NIA Percent Of Coverage Obtained > 90%: No Reviewed Prev!ous Datw Yes Examiner Level III-N _ gnature Mate Reviewe S!inature Date Staffer', Lester, E. 1114f2010 1 , / C3 Examiner Level ll-N ..Date :Site Reviev nature D Peterson, Dre. 8 11-412010 Other Level WA ~Sign'ature Date A'NII Review y.Date N/A Al iA*~(v~~~~Site/Unit: Summary No.: Workscope: UT Calibration/L .amination Oconee 1 3 03.B9.11.0064 Procedure: Procedure Rev.: Work Order No.: PDW-T-2 Outage No.: 03-25 Report No.: UT-10-645 Page: 2 of 6 ISt 01878533 Code: 1998J2000A CatAlem: B-J 1B911 Location: Rx Bldg.Drawing No.: ISI-OCN3-010

== Description:==

Safe End to Nozzle System ID: 50 Component ID: 3-PIB2-8 Size/Length: NIA Thickness/Diameler: 2.33133.51SS Limitations: Yes -See attached sheet Start Time: 1127 Finish Time: 1200 Instrument Settings Search Unit f al Time .Date Serial No.: 014738 Ser! No.: SE0355 / Checks __"_'Manufacturer: KRAUTKRAMER Manufacturer: k-A Initial Cal., 1025 1114/2010. Model: USN-6O SIN .50 Shape Round " lInter.-Cal'.. Delay: 7.8484 Range: 12.00 Freq.: 2.25 MHz Style:; Comp-G Inter. Cal. 1207 11,4/2010 M'tl CalVel: 0.1235 Pulser: Square Exam Angle: s0 #of Elements: single !Inter. CaL ,, .Damping: 500 Reject: 0% Mode: Shear Rep. Rate: Autohigh Freq,: 2,25 Measured Angle: 60 Couplant Filter Fixed Mode: PE Wedge Style: MSWQC Cal. Batch: 09325 Voltage: 450 Other: Fullwave Type: ULTRAGEL II Ax. Gain (dB): 42.3 Circ. Gain (dB): 42.3 Search Unit Cable Mfg.: SONOTECH 1 Screen Div. = 1.20 in. of Sound Path Type: RG -174 Exam Batch: 09325 Linearty Report No.: L-10-1 10 Length: V' No. Conn.: 0 Type: ULTRAGEL i1 Calibration Block Scan Coverage Mfg.: SONOTECH Cal. Block No.: 40397 Upstream W Downstream[E Scan dB: 48.3 Reference Block Thickness: 3.000 Dia.: Flat CWRJ CCWRJ Scan dB: 48.3________Serial No.:....04-8743 Cal. Bik. Temp.: 70 Temp. Tool: MCNDE40132 Exam Surface: O.D Type: ROMPAS Comp. Temp.: 75 Temp. Tool: MCNDE40132 Surface Condition: As Ground Recordable Indication(s): Yes El No [ (if Yes, Ref. Attached Ultrasonic Indication Report.)Results: Accept [ Reject [] Info Comments: N/A Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes Axial Orlentated Search Unit Ca1ibrtio on Signal Sweep Sound Path Reflrctor I Amplitude % Division ID Notch * .. .. .to Notch 80 1 4.3 5.414 I Circumferential Orientated Search Unit Calibration Signal DvSweep Reflector j Amplitude % Division Sound Path See Axial ___, ___ __,, _ , __........_ t, .. .___ I I Reference/SIreulator Block d S Reflector Amrplitudo % Swep Soun dPt 15 2" Radius 97 1.7 2.019 PAi 51, E.SitelUnit: Summary No.: UT CalibrationiL .amination Oconee 3 03.139.111.0064 Procedure: Procedure Rev.: PDI-UT-2 E Outage No.: 03-25 Report No.: UT-10-645 Workscope: is1 W-ik Orde. No., 01575533 Page: 3 of 6 Code: 99812000A Cal./Item: l*J iB9.11 Location: Rx Bldg.Drawing No.: ISI-OCN3-010

== Description:==

Safe End to Nozzle System ID: so Component ID: 3-P122-8 Size/Length: MIA Thickness/Diameter: Z33133.5/SS Limitations: Yes -See attached sheets Start Time: 1127 Finish Time: 1200 Instrument Settings Serial No.: 014738 Serial t Manufacturer: KRAUTKRAMER Manufa Model: USN-60 SW Size: Delay: 11.6894 Range: 10.00 Freq.: M'tl Calvel: 0.2188 Pulser Square Exam A Damping: S00 Reject: 0% Mode: Rep. Rate: Autohigh Freq.: 2.0 Measur Filter: Fixed- Mode: Dual Wedge Voltage: 450 Other:. Fulhwave Ax. Gain (dB): 46.9 Circ. Gain (dB): NIA 1 Screen Div. , 1.0 in. of Sound Path Type: Search Unit Cal. Time Date Jo.: 10-1203 Checks cturer: Kilt Initial CaLt 1034 111412.010 2(24x42)114L Shape: Rect. Inter. Cal. 1126 1114120' 010 , 2.0 MHz Style: TRLA inter. Cal., Inter. Cal.,25 11141201060 #of Elements: Dual Ite, , L .Final Cal., 13101 1112010 Long.- -.ed Angle: 60 Couplant Style: Integ al Cal. Batch: 09325 Axial Orientated Search Unit I Circumferential Orientated Search Unit Search Unit Cable RG -174 Linearity Report No.: L-10-1t0 Length: 6' No. Conn.: 0 Calibration Block Scan Coverage Cal. Block No.: 40397 Upstream g Downstream[- Scan dB: 57.4 Thickness: 3.000 Dia.: ..... lat_ _ CW[ CCW[] Scan dB: NZA Cal. BIk. Temp.: 70 Temp. Tool: MCNDE40132 Exam Surface: 0.1 Comp. Temp.: 75 Temp. Tool: MCNDE40132 Surface Condition: As Ground Recordable Indication(s): Yes [ No j] (If Yes, Ref. Attached Ultrasonic Indication Report.)Results: Accept E] Reject W Info 11 Percent Of Coverage Obtained > 90%: .No Reviewed Previous Data: __ Yes Type: ULTRAGEL II Mfg.: SONOTECH Exam Batch: 09325 Type: ULTRAGEL 11 Mfg.: SONOTECH Reference Block Serial No.: 04-8743 Type: ROMPAS Calibration I Signal tSweepI Reflector Amplitude Division ound Pfth Referertce/Slmulator Block Gain i I Signal I Sweep Sound Path dB [Reflector {Amplitude % I Division 40 RadiuS" 86 1.9 ' 1.971 Comments: NIA A4 I K 6 f~ /DUKE POWER COMPANY ISI LIMITATION REPORT ICompornentlWeld ID: 3-POB12-B8 Item No: 03.B9.11.0064 remarkis: 1 NO SCAN SURFACE BEAM DIRECTION No scan due to cast stainiess E1 LIMITED SCAN X 2 [1 ] 2 0 cw l ccw pum casin FROM L N/A to L N/A INCHES FROM WO CL to Beyond_ANGLE: [] 0 0 45 [@ 60 other 60RL FROM 0 DEGto 360 DEG[] NO SCAN SURFACE BEAM DIRECTION[1 LIMITED SCAN []I [I 2 [l 1 [E 2 L cw 0 ccw FROM L _ to L INCHES FROM WO ___ to ..... .ANGLE: [1 "0 [1 45 [E 60 other FROM DEG to DEG[] NO SCAN SURFACE BEAM DIRECTION[1 LIMITED SCAN [ 1 [1 2 [1 1 [ 2 [1 cw [l ccw FROM L ._ _to L INCHES FROM WO to ....... __ _ANGLE: [1 0 [n 45 [ 60 other FROM DEG to, DEG,[1NO[1 LIMI FROM L ANGLE: SCAN TED SCAN SURFACE BEAM DIRECTION* [1 1 [ 2 [1 [1 2 [] cw[1 ccw UT-1Q0-645 I to L[ 0 [n 45 [160 ot INCHES FROM WO to, Sketch(s) attached her 0 I ppared By: Lester sfaV. J~iv1 IReviewed B-t PA fI I~ A qHMNI('Supplemental Report Report No.: UT-1 0-645 Page: 5 of Summary No.: 03.89.11.00$4 Examiner: .Stauflor, Leste r~f ., , Examiner: 'Pefrson, Drew Other: MIA Level: Level: Level: ill-N i11-N NIA Reviewer: Site Review: A ANII Review: Date: Z0 Date: Date: Comments: r ~PI Pe Sketch or Photo: 66=RL 4O6 FAo~-)Z5 C-

  • SDeter , Site/Unit:

Oconee / 3' Summary No.: 03.B9.11.0064

  • '- Workscope:

ISI mination of Percent Coverage for UT Examinations -Pipe Procedure: Procedure Rev.;Work Order No.: PDI-UT-2 01878533 Outage No.: 03-25 Report No.: UT-10-645 Page: 6 of 6 45 deg Scan 1 Scan 2 Scan 3 Scan 4% Length X%Length X 100.000 % Length X 50.000 100.000 % Length X 50.000% volume of length 1100 =% volume of length / 100 =% volume of length 1100 =% volume of length / 100 =% total for Scan 1% total for Scan 2 50.000 % total for Scan 3 50.000 % total for Scan 4 Add totals and divide by # scans = 50.000 % total for 45 deg Other de -60 (to be used for supplemental scans)The data to be listed below is for coverage that was not obtained with the 45 deg scans.Scan I Scan 2 Scan 3 Scan 4 100.000 % Length X 60.000 0.000 % Length X 0.000% Length X% Length X% volume of length / 100 =% volume of length 100=% volume of length /100 =% volume of length / 100 =50.000 % total for Scan I 0.000 % total for Scan 2% total for Scan 3% total for Scan 4 Percent corn lete coverage Add totals for each scan required and divide by # of scans to determine; 37.500 % Total for complete exam Site Field Supervisor: Date: II P AG 6 7 F af-Site/Unit: Summary No.: Workscope: UT Calibration/L .amination Oconee ' 3 03.B9.11.0064 ISI Procedure: NDE-830 Procedure Rev.: -I Work Order No,: 01878533 Outage No,: 03-25 Report No.: UT-10-648 Page: 1 of 4 Code: 1998/2000A W-Mt B-J 189.11 Loclion-: Rx Bldg.Drawing No.: ISI-OCN3-010

== Description:==

Safe End to Nozzle System ID: 50 Component ID: 3-PIB2-8 Size/Length: N/A Thickness/Diameter: 2.33133.5/SS Limitations: Yes -See attached sheets Start Time: 1214 Finish Time: 1247 Instrument Settings Search Unit cal. nTime Date Axial Orientated Search Unit Serial No.: 00WHDK Serial No.: 03-789 Checks _ _ ate A Mnfcue. .URAEMnuaur Calibration Signal Sweep Sound Path Initial Cal. 0844 111412010. Reflector Amplitude % Division Model: USN.60 Isnze: 2Cal.33)1 4 T Hole 50 4.8 1 .3.28 Delay: 16.7'06 Range: 7.0 .Fe.- 1.0 Mz, sI " Intel. CalS.: 1213 11144;6i10":3,'T1o } _ ._ _ .M't1 CaVVel: .2600 Pulser High Exam Angle: SOL ý#o.fElemens.- bD,- inter. Cal I , Damping: 1K Reject: 0% mod Long, -inal Cal. 1532 115302. , Rep. Rate: Autohigh Freq.: 1.0 Measured Angle; " .Couplant ... ..Filterý Fixed Mode: Dual Wedge Style: Integral Cal. Batch: 09325 Circumferential Orientated Search Unit Voltage: Fixed Other. Fullwave Type: ULTRAGEL It Cafibration Signal I .Sweep ISund Path Ax. Gain (dB): 70.1 Circ. Gain (dB): 71.2 Search Unit Cable Mfg.: SONOTECH Refiecor Amplitude

  • A Division ...a I Screen Div. = .7 in. of Sound Path Type: RG -.174 Exam Batch: 09325 314THole so .3__9 Linearity Report No.: L-10-109 Length: 6. No. Conn.: -Type: ULTRAGEL 11I_____Calibration Block Scan Coverage Mfg.: SONOTECH 1 1 Cal. Block No.: S0214 Upstream [J Downstream

[] Scan dB: 72.6 Reference Block ReferencelSlmulator Block Thickness: 2.464 Dia.: Flat CWR CCWR- Scan dB: 72.6 Serial No.: 0-9 Gain Signal Sweep Sound Path Cal. Blk.Temp.: 70 .Temp. Tool: MCNDE40132 Exam Surface: O.D. dB I ReAlector % Division____Type: ROMPAS 30.2 12- Radius, e80 28 f 20 Comp. Temp.: 72 Temp. Tool: MCNDE40132 Surface Condition: As Ground Recordable Indicatlon(s): Yes ] No [ (if Yes, Ref. Attached Ultrasonic Indication Report.)Results: Accept [] Reject [] info Comments: NIA Percent Of Coverage Obtained ' 90%: MIA Revewed Previous Data: Yes Examiner Level lý ftn4/DteRvlwi l Griebel. David M. 'Z , . .'.90°'Examiner Level o.,4 Dale Site evie0w Signature Data Hendrickson, Matthewf410 Other Level NIA -SntueDate ANII-ReviewSinur Date A h P A [i-Jk Site/Unit: Summary No.: Workscope: UT CalibrationlL..amination Oconee 1 3 03.B9.11.0064 (St Procedure: Procedure Rev..Work Order No.: NDE-830 Outage No.: 03-25 Report No.: UT-10-648 Page: 2 of 4 01878533 Code. 199812000A Drawing No.: ISI-OCN3-010 System ID: 50 Component ID: 3-PIB2-8 Limitations: Yes -See attached sheets Catl.ltem: B.J IB9.11

Description:

Safe End to Nozzle Location: Rx Bldg.Size/Length: NiA ThicknessJDiameter: 2.33133.5JSS Start Time: 1250 Finish Time: 1322 Instrument Settings Serial No.: OOWHDK Serial h Manufacturer: KRAUTKRAMER Manufa Model: USN-60.Delay- 10.6653 Range: 5X00 Freq.:Calwea: .2392 Pulser: High exam A Damping: 1K Reject: 0% 1Aode: Rep. Rate: Autohigh Freq.: 2.0 Measun Filter Flied Mdde: Dual Wedge Voltage: Fixed Other. Fuliwave Ax.:Gain (d0): 80.0 Circ. Gain (dB): NIA' Screen Div.= 5 in. of Sound Path Type: Search Unit 1o.: 90-371 clurer: RTO 2 0 1Oi, Shape: Red.2.0 MHz Style: TRL.A ngle: 70 t of. Elements: Ouat LongAngle: 70 Style: Integral.Search Unit Cable RG -174"Lineeity Report No.: L-10-09 Length: G' No. Conr.: 0 Calibration Block Scan Coverage Cal. Block No.: 50214 Upsiream 0 DownstreamW Scan d8: 80.0 Thickness: 2.464 DVa.: Flat CW- CCW66 Scan dB: 80.0 Cal. Blk. Temp.: 70 Temp. Tool: MCNDE40132 Exam Surface: O.D.Comp. Temp.: 72 Temp. Tool: MCNDE40132 Surface Condition: As Ground Recordable Indicationis): Yes [I No 0 (If Yes, Ref. Attached Ultrasonic Indication Report.)Results: Accept [] Reject W] Info 11 Percent Of Coverage Obtained > 90%: NIA Reviewed Previous DWta: Yes.Couplant Cal. Batch: 09325 Type: ULTRAGELII Mfg.: SONOTECH Exam Batch: 09325 Type: ULTRAGEL II Mfg.: SONOTECH, Reference Block Serial No.: 04-8739 Type: ROMPAS Calibration I Signal Sweep Reflector Amplillude % { iviion 1 Souid Path WA _ _ _ _ _ _ __ _ _ I _ ._ I_Reference/Simulator Block Gain Signal Sweep I*A Reflector Amplitude % Division Souhd Path 80 4.00 7.00 Circumfetential Orient"fed Search Unit Comments: Unable to discern 114T Hole In circ. direction. Ex~iminer Level liae.Nvee ~Se~lr l'Griebtil, Dwavd 41. 11114120101 rE_'ýminor 7Level ii4I D latej Silo Review Signature Dat Hendrickson, Matthew '.~'- a'AI eiw O0lher Level NI Signtr Dat Signatvewurate Pl A M~ 6 F '2 DUKE POWER COMPANY _ISI LIMITATION REPORT I ComponentlWeld ID: 3-PIB2-8 Item No: 03.B9.11.0064 remarks:[ NO SCAN SURFACE BEAM DIRECTION Procedure allows scanning from C] LIMITED SCAN E 1 1 [12 cWE ccw cast side only.FROM L N/A to L N/A INCHES FROM WO CL to Beyond ANGLE: E] 0 L 45 0 60 other 70 FROM 0 DEG to 360 DEG L1 NO SCAN SURFACE BEAM DIRECTION LI LIMITED SCAN Li1 [12 L1 [I 2 cw [I ccw FROM L to L, INCHES FROM WO to ANGLE: E3 0 [D 45 [3 60 other FROM DEG to DEG Li NO SCAN SURFACE BEAM DIRECTION LiLIMITED SCAN L1 I n2 Li 1 E 2 fi cw [3 ccw FROM. L toL INCHES FROM WO to ANGLE: Q 0 [] 45 [] 60 other FROM DEG to OEG Li NO SCAN SURFACE BEAM DIRECTION LILIMITED SCAN Li1 Li2 Li1 [] 2L cwi ccw UT-10-648 FROM L _ _ to L INCHES FROM WO to Sketch(s) attached ANGLE: [] 0 [3 45 Li 60 .other FROM DEGto DEG yes Li No d1e Date: D11/Se.0 ReViewed By. pate: Date: P AG6E G7 QF Supplemental Report Report No.: UT-10-648 Page: 4 of 4 Summary No.: 03.,9,11.0064 Examiner. Griebel, David. , .7.......... Examiner: Hendrfbkson, Matthew -VeV e I.-N, Other NIA. .L evel: NIA Reviewer.Site Review: ANII Review: z Date: Date:_________ D~ate: I______a_ 1(-iJtA Comments: Best effort exam using 60"RL & 70'RL per NDE 830 for upper 2/3 area of interest.=i=-z /i I t 1 I.I ---.- -_j F'1/li7P 5-2-- PA&Ejo 6 l 0 K.~: e~tinit: Oconee S~rn~ry f4o: UT Calibration/Examination 13 03.59.11.0070 Procedure: Procedure Ryv.: Work Order No.: PDI-UT-2 01879038 autaqc:mlo.: 03-25 Roport.Nlo.: UT-1 0-658 Pave. I of S Code: 419972IJOOA Oatlot: 9-1J I9.11 Location: RxBldg, Drawing No.: ISI-OCN3-Ol2

== Description:==

Nozzle to Safe End System ID: so Component iD: 3-PDA2-1 SIX4/Lengfth NIA ThicknessfDlameter: 2,33(33.5!SS UmIltaions: Yes -See attached sheet Start Time: 1116 Finish Time: 1131 intrumnent Settings Search Unit Cal. Timea oDat. Axial Ork'rWted S rch Unit Serial No.: 014BLC ., Serial No.: 010SLJ Checks _, j 'ignal S;eoo P5Th Manufacturer: KRAUTKRAMER Manufacturer:. KBA FInllalsCal 111412010 P,1i.ct3r rnplide %s'Model: USN-60 SW Size: 0.50 Shape: Round Inter. Cal. jIt Nolh 5,4 23S _Delay: 7.5947 Range: Freq.: 2.25 M.z Style: Comp-oG Inter. Cal. 1050, il/412010 M1 a e. 16 .P lo:Inter. Cal.l ' l " .." "-]i M~ l a ' : : 2 .r: J , ..*f O E x a m A n g l : 4 -5 # o f E e m re n ts

  • S in l .:
  • l Z S : o 1 ]DampinT29!

I0 0% "- ~a ~ Ser- final Cal 1,250;1 1-11412010 Dapn. 6 Reject: =% Mode-____ Shelf_ _________Rep. Rate:, Autchlgh Preq.: 2.25 Measured Angle: A3 Couplant ______Flilter: Fixed Mode: PE Wedge Style: MSWQC Cal. Batch: 09325 Circ-imferenltfif rint!azrd Soirch Un!t Voltage: 450 Other. Fullwave Type: ULTRAGEL II Calibratin Signal SGwoen a Patti Ax. Gain (dB): 29.7 Circ. Gain (dB): 29.7 Search Unit Cable Mfg.: SONOTECH ReDievtsr Attxne % j Drskon iSri:rn1 lti 1 Screen DIV. .8 In- of Sound Path Type: RG.- 174 Exa Bath' 0032 See Axtel J Linearity Report No.: L-10-115 Length: 6' No. Conn.: 0 Type: ULTRAGEL II Calibration Block Scan Coverage Mfg.: SONOTECH " t _ _ _ _i Cairto Bloc I !Cal. Block No. 40397 Upstream [] Downstream Scan dB: 41.7 Reference Block RemncelSlmuitor tl. s;Thickness : Flat CW Rj COW Scan dB: 41.7 G:0a Signal S t -____________~~~~ Serial No.: 04ýS4?4 d eakrApiueDvs~ Cal, a1. Temp. k2 Tamp. To):, MCNDE40132 Exam Surftice: _ _ _Type: ROMPAS j'2. R5" dius .0 2.5 -Comop. Temp. 74 Temp. ,Tool; 940NDF401i2 Surface Condition:. Asý Ground Recordable Indication($).* Ye's E No 9 (IfYos, Ref. Attached Ultrasonic In~dlcafionr Report.)Results: Accept Reject S lnIi Comments: NIA Percent Of Coverage Obtained > 90%: No ReyfaWed Previous Data: Yes Examiner LcVel II.N ilr ~u~e Bul .Kih1114=190 Moss;Gary ..Examiner Le. W 11 Dt4/2010 _NIA.XIAJ Z-i~2 I - AA~~i~i (i P4FE /UT Ca SlletlUnit: Oconce e Summary No.: 03.89.11,0070.Workscope: 151 libration/Examination Procedure: PDI-UT-2 Procedure Rev.: E Work Order No.: 01879038 Outage No.: 03-25 Report No.: UT-10i658 Page: 2 of " Code: 199812000A Drawing No.: ISI-OGN3-012 System ID: a Component ID: 3-PDA2-1 Limitations: Yes -See attached sheet C Drtptem: ..... N 13 Sa9. f d Descr'iption: Nozzle to Safe End Location: Rx Bldg.Size/Length: MIA ThicknesslDiameter: 2.33133.51SS Start Time: 1227 Finish Time: 1242 Instrument Settings Seral No,: 0146LC Scial Manufacluror .KRAUTKR-AMSR ManufrUSN-60 SW Dely: .2203 Range. F .: M't Cavelý: .2121 Puls&i:, _ Exam_Damping: 5o0 ReJecGt 0% M Mode&Reao Rate: Autohigh FreN.: 2.0 Me n Filter: Fixed Mode: Dual Wedge Vaitege: 450 Other: Fuiwave Ax, Gain (dBy 4j.2 Ctrc. Gain CdB) NUA" Screen Div. = 1.0 in, o' Sound Pa!h Type: Unr--arty Report Noý: Len-th: Calibration Block Search Unit 40- 10-U204 ,cturer .--2{24x42)1t4L. Shapo: Reoct 2.0 ML- Style: -TRL 2 ongle: to +of Elem +ntw: Dual, Long;ed Angle: s0.Style: IntograI Search Unit Cable R. 4 Couptant Catl. Batch: '09325, Type: ULTRAGEL It Mtg.: SONOTECII Exam Batch: 09325 T ype: U LTRAGEL It Mfg.: SONOTECH Reference flock Clrrm~renlatOricn~totd Seaorch Unat~~i~fnF fSweep V No. Conn.: 0 Seen Coverage Cal. Block No., 40397 iUpstream D] Downslteam [] Scan dB: 60.5 Thickness 3.000 Die.: Flat CW El COW C] Scan dB: N/A Cal. 81k. Temp. 62 Temp. Tool: MCNDE40132 Exam Surface: 0.D Comp. Temp. 74 Temp. Tool: MCNDE46132 Surface Condition: As Ground Recordable Indication(s): Yes (3 No W (If Yes, Ref. Attached Ultrasonic Indication Report.)-Results: Accept E) Re]ecl 2 Info 0 Percent Of Coverage Obtained> 90%: NO Reviewed Previous Data: Yes Re6ferancelSieuft ator B lock Serial No.: 04.8744 Type: ROMPAS I.dS Sig"nl Swepp n IifelrAnipDliftrde

  • l tXtsin! I d "" ar r19.1 j 2" Radiuel 7S 1AI t Comments:

NIA PATF~a T 73 I SitelUnit: Oconee Summary No.: Workscope: UT Calibration/Examination 03.89.11.0070 Procedure: Procedure Rev.: Work Order No..PDI-UT-2 01879038 Outage No.: 03.25 Report No.: UT-10-658 Page: 3 of 6 Code: 1998I20DDA CtrJlte.r.: .*. .159.11 Localion: Rx Bldg.Drawing No.: ISS-OCN3-012 "escriptlgn: NqzrJc to Safe End System ID: so, Component ID; 3-__DA2-_ Size/Length: NIA Thickness/DIameter: 2.33133.5/SS Limitations: Yes -See attached sheet Start Time: Ii52 FinishFime; 1208 Instrument Settings Search Unit Cal. Tie _Date Manufacturer: KRAUTKAMER Manufadcurer GE Initial Cal ?031 11/1420 10 Mode,: US--8 SW Size: 0.50 Shape: Rotmnd Cainter. cal. ... _Delay- 9.S100 Rarre: 12450 F~OQ.~ 225 MH; Slyle: -C ; -G Inter. Ca.I 1135 111412010 M'U CiiVvel: .1232 Puilse. -44 Sxi nl: 7 1 feotx In inter. Cal. ___D 1arping:, 500 Refect 0% ,?-Mode: -,Shear FniCl 14 1M Rep. Rate: Autohlgh Freq.: 2.25 Measured Angie: 71 Couplant Filtle Fixed Model: _ PE Wedge Style: MSWQC Cal. Batch: 09325 Voltage: 450 Other- Futziwv Type: ULTRAGEL II Axy Gafn (dO): 54.5 Cbr. Gain (fB): NWA Search Unit Cable Mfg.: SONOTECH I Screen Div. = 125 In. Dfr Sound Path Type: RG -174 Exam Batch: 09325 Unearity Report No.: L.10-115 Length: 61 No. Conn.: 0 Type: ULTRAGEL II Calimtiton Block Scan Coverage Mfg,: .. SONOTECH Cal. BlocM No. 40397 Upstam 5 Scan dS: 60.5.....-.. ..Refueronco PlOCk Th)cknnss 2.00, DPa.: Fiat CW 0 CCW 5] S4candB NIA Seral o.: 0"4744 Cal. BIk. Temp. 62 Temp. Toot: MCNDE40132 Exam Sur.ce: O'D Type: ROMPAS Comp. Temp. 74 Temp. Took MCNDE40132 Surface Condilion: A-- Ground Recordable IndlCation(s): Yes 5 No [] (!f Yes. Ref Attached Uitrasonic IndIcation Report.) .Results: Accept 0 Reject g Into 5 Comments: NIA Axial Orientated Search U nlt Callbreton signal Sweep I1Sound Path Refi4dbr Ampltiude % iVis'19n ID Notch so 80.7 8-375j________ t ______, _____ _____ClrcumferentfatOrlentatod'Seartýh Unit COilbraton Signal sweep " Rectr Amplitude % DMslon ~Sound P!tl ReflerenceljSimlator Block Gain Stgnal I Swveep dI. R..l...IA slItude %I Division.So.n 10.0 2- Radius go I.8 L-T A T I A4 6E : " DUKE POWER COM[PANY ISI LIMITATION REPORT-, ....Component/Weld ID: 3-PDA2-1 Item No: 03.B9.11.0070 remarks:[ NO SCAN SURFACE BEAM DIRECTION U LIMITED SCAN U] 1 0 2 []1 n] 2 [] cw E] ccw FROM L N/A to L N/A INCHES FROM WO CL to -Beyond_ANGLE: E] 0 [] 45 Z 60 other 700 FROM 0 DEG to 360 DEG U NO SCAN SURFACE BEAM DIRECTION-U LIMITED SCAN Ul 1 U 2 U 1 U 2 U cw U] ccw FROM L to L__ INCHES FROM WO _ to ANGLE: [20 [0 45 [260 other FROM DEGto DEG U NO SCAN SURFACE BEAM DIRECTION U LIMITED SCAN Ui 1 2U, n cw ccw[FROM L toL INCHES FROM WO to ANGLE: Ul 0 [2 45 U 60 other FROM DEG to DEG UN'FROM L ANGLE: 0 SCAN MITED SCAN SURFACE UJIUEj2 BEAM DIRECTION U] 1 Ul 2 Ul Cw U] cow UT-1O-58 to L U] 0 [2 45 [] 60 other INCHES FROM WO to Sketch(s) attached DEG to _ -P.G I yes FROM k Supplemental Report Report No.;Page: UT-i0-656 5 Of 6 Summary No.: 03.B9.11.0070 Examiner: Bell, W.KeIM Examiner: N /Other: WA Level: I-N Level: NIA Level: N/A Reviewar: Site Revlew. WfA ANNI Re~iow:-U-5A.- ý., Date: 1119/2010 Date:.Date: Comments: Sketch or Photo: 30 t Site/Unit: Oc Determination of Percent Coverage for UT Examinations -Pipe.onee / 3 Summary No.: 03.B9.11.0070 Workscope: 13)Procedure: PDI-UT-2 Procedure Rev.: E Work Order No.: 01879038 Outage No.: 03.25 Report No.: UT-10-858 Page: 6 of 6 45 dov e Scan 1 % Length X % volume of length 1100 =Scan 2 % Length X % volume of length I 100 =Scan 3 100.000 % Length X 50.000 % volume of length / 100 =Scan 4 100.000 % Length X 50.000 % volume of length 1100 =6/% total for Scan 1% total for Scan 2 50.000 % total for Scan 3 50.000 % total for Scan 4 Add totals and divide by # scans = 50.000 % total for-45 deg Other deg- 70 (to be used for supplemental scans)The data to be listed below Is for coverage that was not obtained with the 45 deg scans.)Scan 1 Scan 2 Scan 3 Scan 4 i00.000 % Length X 50.000 % volume of length / 100 =D.000 % Length X 0.000 % volume of length 1100 =% Length X % volume of length /100 =% Length X % volume of length / 100 =50.000 % total for Scan 1 0.000 % total for Scan 2_,% total for Scan 3% total for Scan 4 Percent comolete coverage Add totals for each scan required and divide by # of scans to determine; 37.500 % Total for complete exam Site Field Supervisor: , A Y K Date: ,/t.) SitelUnh: Summary No.: Workscope: UT Calibration/".amination A tACFMaNI Outage No.: 03-25 Report No.: UT-10-649 Page: 1 of 4 Oconee t 3 03.89.11, 0070 Procedure: Procedure Rev.: Work Order No.: NOE-830 01879038 Code: 1998/200DA Cat. tem. B-J 1B9.11 Location: Rx Bldg.Drawing No.: iSIOCN3-012

== Description:==

Nozzle to Safe End System ID: 50 Component ID: 3-PDA2-1 Size/Length: NIA ThicknesslDiameter: 2.33,33.5/SS Limitations: Yes -See attached sheets Start Time: 11i9 Finish Time: 1140 Instrument Settings Serial No.: OOWHDK Manufacturer: KRAUTKRAMER Model: USN-60 Delay: 16.7506 Range; 7.0 Mtl Cal/el: .2600 Pulser: High Damping: 1K Reject: 0%Rep. Rate: Autohigh Freq.: 1.0 Fitter: Fixed Mode: Dual Voltage: Fixed Other. Fullwave Ax. Gain (d8): 70.1 Circ. Gain (d0): 71.2 1 Screen Div. = .7 in. of Sound Path Linearity Report No.: L-10-109 Search Unit I Cal. T mo Serial No.: 03-789 Checks I Manufactdrer: RTD Initial Cal. 0844 1 Site: 2C20x34) Shape Ret Inter. Cal.Freq.-: 1.0 M~ sw TIRL1 Inter. Cal. 1108 1 1ExamAngle: SOL #ol Eleaments: Dual Inter. Cal.Mode: Long -Final Cal. 1532J Measured Angle: Couplant Wedge Style: Integral Cal. Batch: 09: Type: ULTRAGI Search Unit Cable Mfg.: SONOTE Type: RG -174 Exam Batch: 09 Length: 6. No. Conn.: 0 Type: ULTRAGE Scan Coverage Mfg.: SONOTEOrie ntzed Search Unit.Caltbrat.ýn Rer'ectocr Si~~Soun Path~ccr Arrpitu-de Divýep Iku~dP 4. .4 .4. 4.314 T Hole s0 I 4.S 3.28 I df)flfl¶A at 4. .4 .4.I Circumferentinl Oricntated Search Unit Calibratlion I$igral jSvieep Rel1-ctor

  • ,motilude

% S cvis n d Pa, h ,314 T Hole 80 5.2 j 3.59 R..e.enceRsirnulaStr Block Gain Signal .R 1 8 e.S ep d -dO Reaictor Amnplitude % Disicl on~30.2 21 Radius go, 2.8 7-00o Calibration Block Cal, Block No,: 50214 Upstream v Downstream 0 Scan dB: 72.6 Reference Blo Thickness: 2,464 Dia.: Fiat CW[-j CCWRJ Scan dB: 72.6 Serial No.: 04-8739 Cal, Bk. Temp.: 70 Temp. Tool;. MCNDE40132 Exam Surface: O.D. Type: ROMPAS Comp. Temp.: 72 Temp. Tool: MCNDE40132 Surface Condition: As Ground Recordable Indication(s): Yes U No ( (If Yes, Ref. Attached Ultrasonic Indication Report.)Results: Accept 0 Reject RJ Info M Comments: N/A Site/Unit: Summery No.: Workscope: UT Cali brationlL....am ination Oconee / 3 03.89.11.0070 Work Order Noý: NDE-830 A IIACWHMEV/J Outage No.: .03-25 Report No.: UT-10-649 Page: 2 of 4 I1 Ist 01879038 Code: 199812000A Cat/item: B-J 119.11 Location: Rx Bldg.Drawing No.: ISI-OCN3-012

== Description:==

Nozzle to Safe End System ID: so Component ID: 3-PDA2-1 Size/Length: NIA Thickness/Diameter: 2.33133.5ISS Limitations: Yes -See attached sheets Start Time: 1142 Finish Time: 1214 Instrument Settings Search Unit Cal. Time Date Axil Orientad Search Uni Serial No.: OOWHDK Serial No.,: 90-371 1 Checks m .ot, AaOet S Un.t Manu e Initial Cal -0846 11420`0 Calibration Signal Sweep Sound Path Manufacturer: KRAUTKRAMER Manufacturer RTD Reflector Amplitude % Division M, od el, U S N. 6 0 S it : 2 (1O xs S h ap e: R e' " l" nt er .C a " 1/4 H' 1 .0 o , .o le so 3 .8 1 .8 9, Delay: 10.6653 Range: :5.00 Freq.: 2.0 MHz Style: Inter. Cal. 2114 111412010 M1t Cal/Vel: .2392 Pulter: High exam An~gle- , 0 #.ofElemalai Dual l Inter. Cal., ' _Damping: 1K Reject: 0% Mode: Long -Rep. Rate: Autohigh Freq.: 2.0 Measured Angle: 70 Couplant .. .. .._ _Filter: Fixed Mode: Dual Wedge Style: Integral Cal. Batch: 09325 Circumferential Orientated Search Unit Voltage: Fixed Other: Fulfwave Type: ULTRAGEL If Calibrati ,or, Signal Sweep .Ax. Gain (dB): 80.0 Circ. Gain (dB): N/A Search Unit Cable Mfg.: SONOTECH Reflector Amplitude % Division Kfl d .1 Screen Niv. = .5 in. of Sound Path Type: RG -1174 Exam Batch: 09325 N/A Linearity Report No.: L-1 0-109 Length: 6" No. Conn.: 0 Type: ULTRAGEL 111 Calibration Block Scan Coverage Mfg.: SONOTECH Cal. Block No.: 50214 Upstream [ Downstreamfl Scan dB: 80.0 Rf Block ReferencelSimulator Block Thickness: 2.464 bia.: Flat CW RJ CCW[d Scan dB: 80.0 Gain I Signal Sweep Sound Path Cal. Blk. Temp.: 70 Temp. Toolt MCNOE40132 Exam Surface: O.D. Type: .ROMPAS 36.6 12" Radeflc 80 4.00 7.00 Camp. Temp.: 72 Temp. Toot. MCNDE40132 Surface Condition: As Ground.Recordable Indication(s): Yes LI No [] (If Yes, Ref. Attached Ultrasonic Indication Report.)Results: Accept EI Reject W Info ED Comments: Unable to discern 1t4T Hole in circ. direction. Percent Of Coverage Obtained > 90%: !itA Reviewed Previous Data: Yes['xaminer' Level It-N Siitir Da~ Reviewer S1 ,,ur ,Oste_-,LGreeel aI Date Sit'iRevic'w Signsture Dat'Other Level NIA Signature Date A1,4i .Review Signature Date NIA k) LA- /. A, AH ME DUKE POWER COMPANY ISI LIMITATION REPORT Component/Weld ID: 3-PDA2-1 Item No: 03.B9.11.0070 remarks:[]NO SCAN SURFACE BEAM DIRECTION Procedure allows scanning from[1 LIMITED SCAN M 1 02 1 0 2 Z CW 0 CCW cast sideonly.FROM L N/A to L N/A INCHES FROM WO CL to Beyond ANGLE: [10 [0 45 0 60 other 70 FROM 0 DEG to 360 DEG L] NO SCAN SURFACE BEAM DIRECTION LI LIMITED SCAN [] 1 0I 2 [i 1 E] 2 n cw ccw FROM L ._ to L INCHES FROM WO to _ANGLE: J[1 0 11 45 [ 60 other FROM DEG to DEG S NO SCAN SURFACE BEAM DIRECTION LjLIMITED SCAN L1 [j2 [11 [ 2 [j cw[] cow FROM L .to L INCHES FROM WO to SANGLE: F1 0 [-1 45 [1 60 other FROM DEG to DEG G[1 NO SCAN[1 LIMITED-SCAN SURFACE[1 [12 BEAM DIRECTION[ 1 [n 2 [1 cw [ ccw UT-iO-64e I FROM L ANGLE: to L INCHES FROM WO Sketch(s) attached to[1O[ 45[1 60 91 DEG to DEG[1 No I 0 yes Dat~e: I D' Supplemental Report Report No..Page: A I1ACHMEN I112 IJT-10-649 4 of 4 Summary No.: 03.B.I.0070 Examiner: Hendrickson, Matthew "'Level: 11-N Examiner: GriNbel, Davi K z c Levet: 11-N Other: NIA Level: NIA Reviewer: Site Review: ANII Review: Date: Date: __________ ______ ______ ______ Date: _ _ _Comments: Best effort exam using 60°RL & 70°RL per NDE 830 for upper 213 area of interest.C-I.I I.I A I T AlHMEMNI<PAOEjJD OFir*ftko. UT Ca* SlIe/lUnil: Oconee 1 3 Summary No.: 03B1. 911.0072 Workscope: fSf ilibration/Examination Procedure: Procedure Roy.: Work Order No.: P0I-UT-2 01679354 Outage No.: 03-25 Report No.: UT-10-641 Page: I of 6 Code: 199812000A CatAJiem: B-J 169.11 Location: Rx Btdg.Drawing No.: ISI-OCN3-013

== Description:==

Nozzle to Safe End System ID: R0 Component 1O: 3-PDBI'/l Size/Lenglh: NIA Thickness/lDameter: 2.33133.51SS Limitations: Yes -See attached sheet Start Time: tB15 Finish Time: 1022 Instrument Settings Search Unit I Cal. Time 1 Date Seriai No.: 014738 Serial No.: OF1110K Checks I I____..._Manufacturer: KRAUTKRAMER Manufacturer KEA inittaI CA. 0950 1116/2010 Model: USN-60 SW Size: .50 Shape: Round 1 Cal.Delay: 5'7966 Range: 7.0 F"eq.: 2.25Mtz Style: COMP-. anter. Cl , 1014. 2010, Free -!Inter. Cal. o4 1ro0 MIt CatNel: 0.1234 Pulser: Square Exam Angle: 46 # of Elements: Single ..Damping: 5SO Reject: 0% Mode- -Final Cal. i 1102 1116/20 1 0 Rep. Rate: Autohigh Freq.: 2.26 Measured Angle: 45 Couplant Filter: Fixed Mode: PE Wedge Style: MSWQC Cal. Batch: 09326 Voltage: 450 Other: Fuliwave Type: ULTRAGEL II Ax. Gain (d4): NIA Cira. Gain (dB): 26.8 Search Unit Cable Mfg.: SONOTECH 1 Screen Div. = .70 in. of Sound Path Type: RG. 174 Exam Batch: 09326 Linearity Report No.: L-10-110 Length: 8a No. Conn.: 0 Type: ULTRAGEL It Calibration Block Scan Coverage Mfg.: SONOTECH Cal. Block No.: 40397 UpstreamE] Downstreem[] Scan dB: NIA Thickness: 3.000 Dla,: Ftt CW j CCW -J ScandB: 36.8 Serial No.: 04.8743 Cal, Blk. Temp.: 70 Temp. Tooi: MICNDE40132 Exam Surface: O.D Type: ROMPAS Comp. Tamp,: 86 Temp. Tool: MCNDE40132 Surface Condition: As Ground Recordable Indication(s): Yes EJ No Wj (If Yes, Ref. Attached Ultrasonic Indication Report.)Results: Accept E] Reject 0 Info F1 Comments: N/A Percent Of Coverage Obtained ;ý 90%: No Reviewed Previous Data; Yes/'ýXtal Orientated st"alch Unit C, Siqni)~ Sý -Sounld P'nia ID Netch1 .so 5.7 4,157 I I Circumferential Orientzoed Search unit A I IACHMENT c,, P A 6 F "ýj) .r z7" Sile/u~nhi: Ocbosb Summary No.: Workscope: UT Calibration/Examination 03,80.11.0072 Procedure: Procedure Rev.: Work Order No.: PDI-UT-2 E Outage No.: 03-25 Report No_: UT-10-641 Page: 2 of 6 01879364 Page: 2 of S Code: 19082! 000A Drawing No.: ISI-OCN3-013 System It: 50 Component ID: 3-PDBI.1 Limitatlons: Yes -See attached sheet DCaoJltem: B-J tB9.t1

Description:

Nozzle to Safe End 1-clloItoi: Rx Bldg.Size/Length: N1A Start Time: 1026 ThlcknessiDamteinle: 2.33133.5/SS finish time: 1046 SraNo: instrument Settngs Search Unit Cal. Tm: Dt Serial No.: 014738 Serial No.: SE0365 Checks m__ _ at Manufacturer: KRAIJTIRAMER Manufacturer: KGA initial Cal. 0960 1118120101 Model: USN.o SW Size: .X0 Shape* Round Inter. Cel.Delay: 7.8484 Range: 12.00 Freq.: 2.2 MHz Style: CoM Inter Ca 1024 JIIJG/2010: M'tl CalVel: 0.1235 Pulser; Square Exam Angle: 60 # of Elements: Single In Iter. Cal.Damping: 500 Reject: 0% Mode: 'Shear -Final Cal. 110111161201o Rep. Rate: Autohigh Freq.: 2.25 Measured Angle: so Couplant Filter, Fixed Mode: PE Wedge Style: MSWQC Cal. Batch: 00326 Voltage: 450 Other. Fuliwave Type: ULTRAGEL It Ax. Gain (dB): 42.3 Circ. Gain (d8): -42.3 Search Unit Cable Mfg.: SONOTECH I Screen Div. = 1.20 in. of Sound Path Type; RG -174 Exam Batch: 09325 Linearty Report No.: L10-1'1 Length: 61 No, Conn.: 0 Type: ULTRAGEL II Calibration Block Scan Coverage Mfg.: SONOTECH Cal. Slock No.: 40397 Upstreamfj Downstreamni Scan dS: 49.3 Reference Block Thickness: 3.000 Die.: Flat CW0 CCWO Scan dB: 48.3-Serial No,: 04-67413 Cal. Olk. Temp.: 70 Temp. Tool: MCNDE40132 Exam Surface: 0.0 Type: ROMPAS Comp. Temp.: 8_ Temp. Tool: MCNDE40132 Surface Condition: As Ground Recordable Indication(s): Yea E] No D/ (if Yes, Ref. Attached Ultrasonic Indication Report.)Results: Accept E] Reject &a Info 0 Comments: NIA Percent Of Coverage Obtained > 90%: No Reviewed Previous Date: Yes.I Circurnf6renthil OrL-ntptled Sezrob Unit Sigtrt~rnafl OrottdSawich n ptfle~ct J Amplilueo Division lsdtsfld P;'th Gain S %nt S dO~ ~ ~ ~~' 'eiel 'mtte Di nSu P-'tb-15 12" Radlus 97 2.019 SitelUnil: OMonee m Summary No.: 03.B9.Workecope: 1!tr1ACHE c/W UT Calibration/Examination 3 11.0072 II Procedure: Procedure, Rev.: Work Order No'-POW-UT-2 01879364 Outage No.: 03-25 Report No.: UT-10.641 Page: 3 of 6 C d... .1998/2000A

  • C lAten: B-J 1B9.11 Location:

Rx Wd g.Drawing No.: ISI-0CN3-013 Decriptlon: "Nozzle to Safe End System ID: ell)Component iD: 3-PDBI.1 SizaJdength: NfA Thlckness/Olameter: 2.33133.51SS Limitations: Yes See attached sheets :StdTime: 1007 Finish Time: 1013 Instrument Settings Search Unit COal Time Axial OiantatedSearrh "Un; ".Serial No.! 014735 Serial No.: 10.1203 Checks Gi1rlo inl 1Sre ordPt Manufacturer-. KRAUTKRAMER Manufacturer: RV I nltial.Ca.1 093 2 Re1e1t, Ampi2010e % Orv:s__ __ __ ______ __ __ __M odel: U ,SN- 0 SWSize: .I 4 -In er ct ~ i, : al -.Delay: 11.6894 Range: 10.00 Freq.: 2.0 MHz Style: TRLA Inter. Cal. 1008 111612010 M'tl CafIVel: 0.2188 Pulsar. Square Exam Angle: so # of Elements: Dual Inter. Cal.___Damping: 500 Reject: 0% Mode: Long.- FnlCa.10 11620 Rep. Rate: Autohlgh Freq.: 2.0 Measured Angle: 60 CovUptant " FIfler. Fixed Mode: 6Dira Wedge Style: Integral cal: , Batch: .09325 C ,rum oeont o ntted Scnrch ,,t Voltage: 460 Other: Fullwave Type: uLTRAoEL II Cwllbrtion Signal swan, f .Ax. Gain (dB): 46.9 Circ. Gain (dB): NIA Search Unit Cable Mfg.: SONOTECH Reflecor Ampitude % j Divis~ac ..o n I Screen Div. 1 .0 in. of Sound Path Type: RG -.174. Exam Batch: .09325 N.fA .....__ ..... ........ " Linearity Report No.: L-10-110 Length: 6' No. Corn.: 0 Type: ULTRAGEL If *Calibration Block Scan Coverage Mfg.: SoNOTECK-1.Cal. Block No.: 40397 UpstreamC] Downstreamr Scan dB: 57.4 Reference Block ReferonBe/Sim rlack Thickness: 3.000 Dla.: Flat CWO CCWQD Scan dB: NIA~ Serial No.: 04-8743 Gai Ampitud we e % Divi ior.Cal. B1k. Temp.: 7n Tamp. Tool: MCNDE40132 Exam Surface: 0.3 Type: ROMPASI4lO I!" Comp. Temp.: 86 Temp. Tool: ,MCNDE4013Z Surface Condition: As Ground " u1 .9 7 1 Recordable Yes 0 No 2 (If Yes, Ref. Attached Ultrasonic Indication Report.)Resulis: Accept D Reject 0 Info 0 Comments: NIA Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: yes xa riner Level 11.1N uro z D at a R& viom'4 r ,7 Si /aItt E x a m i n e r L e v o l i u n ....S... ...... ...,Bull, W. Ketl 111,. ..10 Other l.,cvt ,, .Signature. Datej ,ANII Revlaw .luro W/A ~ > 7 U ( AT I A -C HME N P AE62E Q:ý0 DUKE POWER COMPANY ISI LIMITATION RE, PORT ComponentlWeld ID: 3-PDBb1-*Item No: O3.B9.11.0072 ýf I reýmatks: NO SCAN SURFACE BEAM DIRECTION No scan due to cast stainless El LIMITED SCAN I [il 2 El1 R] 2 0 ew ccw pump casing.FROM L N/A to L N/A INCHES FROM WO N/A r-to N/A cy-, ANGLE: Dl 0 Z 45 0 60 other 60RL FROM 0 DEG to 360 DEG 0] NO SCAN SURFACE BEAM DIRECTION El LIMITED SCAN [Ei [] 2 [ii []2 ] cw2 ccw ___R FROM L to L_ INCHES FROM WO to ANGLE: 0l 0 El 45 E] 60 other FROM DEG'to DEG F] NO SCAN SURFACE BEAM DIRECTION LILIMITED SCAN E 1 [] 2 El I [] 2 El cw D] cow FROM L _ to L INCHES FROM WO to _ANGLE: [] 0 [] 45 [] 60 other FROM DEG to _ DEG C] NO SCAN SURFACE BEAM DIRECTION El LIMITED SCAN [] 1 El 2 El I El 2 El rw El ccw UT-1-041 FROM L to L_ __._INCHES FROM WO to _ Sketch(s) attached ANGLE: 0] 0 F] 45 [360 other FROM DEG to DEG es E) No Pre....d By e- s .a Level: Date .... o _Reviewed By Ots ed Iný Date!/vt/ I Supplemental Report ATTACHMENT C P AGE W~ OF 17 Report No.: UT-10-641 Page: 5 of 4 (o.Summar No.: 03.89.11.00T2 Exmaniinr Stauffer, masur, Le~ vel: 1W-4 Eixaminer BUL, W. Keith Level: li-N Othir., NIA Level, NIA Reviewer;Site Review.ANII Review: Date: Date:-Pats L4$ ivAL4tr Comments: I Sketch or Photo: I-4-8 I CAsV SS i t I.42~ -I, I I I I I I -S.-.4 A. JZL, Determination of Percent Coverage for UT Examinations -Pipe Site/Unit: Oconee 1 3 Procedure: PDI-UT-2 0 utage No.: 03-25 Summary No.: 03.B9.11.0072 Workacope; 181 Procedure Rev.: Work Order No.:__Report No.,: UT-10-41 01879364 Page: 6 of 6 J Scan I % Length X % volume of length / 100 % total for Smn 1 Scan 2 % Length X % volume of length /100 a % lotal for Scan 2 Scan 3 100.000 % Length X 50.000 % volume of length/ 1 00, 50,000 % total for Scan 3 Scan 4 100,000 % Length X 50.000 % volume of length 1100 = 60,000 % total for Scan 4 Add totals and divide by # scans = 50.000 % total for 45 deg 9Oh don 60 (to be used for supplemental scans)The date to be listed below Is for coverage that was not obtained with the 45 deg scans.Scan 1 100,000 Scan 2 L40.000 Scan 3% Length X 0.000% Length X 50.000% Length X% volume of length / 100 = 0.000 % total for Scan I% volume of length/ 100 0.000 % total for Scan 2% volume of length / 100 = % total for Scan 3% volume of length 1100 ,, % total for Scan 4 Scan 4 %_ _ %Length X _ _ _Pecent comntete coveraae Add totals for each scan required and divide by # of scans to determine; % Tota for complete exam Site Field Superlsor. ~*Date: t- Site/Unit: Summary No.: Workscope: UT Calibration/l_ amination Outage No.: 03-25 Report No.: UT-10-650 Page: 1 of 4 Oconee / 3 03.B9.11.0072 Procedure: Procedure Rev.: Work Order No.: NDE-830 I SIM 01679354 Codel. 199812000A CatJltem: B-J /09.11 Location: Rx Bldg.Drawing No.: ISl-OCN3-013

== Description:==

Nozzle to Safe End System ID: ad Component ID: 3-PDBI-1 Size/Length: N/A Thickness/Diameter: 2.33/33.5]SS Limitations: Yes -See attached sheets Start Time: 1033 Finish Time: 1104 Instrument Settings Search Unit f Cal. 'rime Date AXIal Or I lentated Search Unit Serial No.: OOWHDK Serial No.: 03-789 8 1SS01t Mnfcue:"RUTR ERManufacturer. RTI Reflector Amplitude% DIVslohn Model: USN-60 Slze: 2(20x34) Shape: Re. Inter.,CaL_ 314 T Note 80 4.8 3.28 Delay: 16.7506 Range: 7.0 Freq.: 1.0 SMt y" T- -I Inter. Cal. 1032 1W16120210 M' CalNel: .2600 Pulser High Exami Angle: 6L ,O t -Elenefnt:

1) Inter. Ca,, Damping: 1K Reject: 0% Mode: Lonig ii........

3 _ 11612010 Rep. Rate: Autohigh Freq.: .. 1.0 Measured Angle: 66 Couplant _Filter: Fixed Mode: Dual Wedge Style: Integral Cal. Batch: 09325 Clrcumferential.Orlentated Search Unit Voltage: Fixed Other. Fullwave Type: ULTRAGEL II Calibr~tton SJ'3a1 Sweep Ax. Gain (dB): 70.1 Circ. Gain (dB): 71.2 Search Unit Cable Mfg.: SONOTECH RelepW -AmnpitUide % DiviSlo ound Path.I Screen Div. = .7 in. of Sound Path Type: RG -174 Eam Batch: 09325 314 T Hole 80 5.2 .3-59 Linearity Report No.: L-10-109 -ength: 6' No. Conn.: 0 Type: ULTRAGEL II Calibration Block Scan Coverage Mfg.: SONOTECH Cal. Block No.: 50214 Upstream [ Downstreamf] Scan dB: 72.6 Reference Block RcrerencefSimulator Stock Thickness: 2.464 Dia.: Flat CCWfR] Scan dB: 72.6 Serial No.: 04-8739 Ga in SA t Syeep sconi h Cal. Blk. Temp.: 70 Temp. Tool: MCNDE40132 Exam Surface: O.D. Type: ROMPAS Am, k l"Radru-I %0 .. .. "2.8 " 2.00 Camp. Temp.: 85 Temp. Tool: MCNDE4D132 Surface Ccndition: As Ground Recordable Indication(s): Yes No [ (If Yes, Ref. Attached Ultrasonic Indication Report.) .Results: Accept [] Reject Info Comments: N/A Percent Of Coverage Obtained P 90%: .. N/A Reviewed Previous Data: Yes.SExaminer Level 'I"tuI Date Revvier nature Hendrickson, Matthew 1612/ 200 Examnlrer Le I ll-N/) -04"Dto Site Review DlýGrtebcf, Cavid .M. ~ / ~ ~~tr 1621 Other Level N/A / SDanttre Date .ANi Review Signature, Date WfA\ Sumnmary No.: Woil(scope: UT Calibration/Lkamination ocoie~e 1 03.9.911.0072 Procedure: ProcedureRev.: 'Workt Order No.: NDE-830 ATTACHMENT P AE 7 £aF T7,-Outage No.: 03-25 Fepcrf No.: UT-10-650 Page: 2 of 4 Rx Bldg.1 Is;01879354 Code: Drawing No.: System ID: 50 Component ID: 3-PDBI-1 Limitations: Yes -see 1998/2000A ISl-OCN3-013 CatIten): B-3 1B9.11

Description:

Nozzle to Safe End Location;attached sheets Size/Length. MIA Start Time: 1107 Thickness/Diameter: 2.33/33.51SS Finish Time: 1137 Instrument Settings Search Unit Seral No.: OOWHDK Serial No.: 90-371 Manufacturer: KRAUTKRAMER Manufacturer: RFTD Model: USN-60 Siz& 2110x18) Shape:. ReCe.Delay: 10.6653 Range:. 5.00 Freq.: 2.0 MWz Style: TRILA M'tl CalNel: .2392 Pulser: High Exam Angle: of Elements: Dual Damping: 1K Reject: 0% Mode: Long I Rep. Rate: Autohigh Freq.: .2.0 Measured Angle: 70 Couplant Filter: Fixed Mode: Dual Wedge Style: Integral Cal. Batch: 09325 Voltage: Fixed Other. Fullwave Type: ULTRAGEL i1 Ax. Gain (dB): 80.0 Circ. Gain (dB): NIA Search Unit Cable Mfg.: SONOTECH 1 Screen Div. = .5 in. of Sound Path Type: RG -174 Exam Batch: 09325 Linearity Report No.: L-10-109 Length; 6" No. Conn.: 0 Type:. ULTRAGEL II Calibration Block Scan Coverage Mfg.: SONOTECH Cal. Block No.: 50214 Upstream El Downstream[a Scan dB: 80.0 Reference Block Thickness: 2,464. Da_: Flat CW R CCWRJ Scan dB: 80.0 Serial No.: 04-8739 Cal. Bk. Temp.: 70 Temp. Tool: MCNDE40132 Exam Surface: O,_ , Type: ROMPAS Comp. Temp.: 85 Temp. Tool: MCNDE40132 Surface Condition: As Ground Recordable Indication(s): Yes F1 No a] (if Yes, Ref. Attached Ultrasonic Indication Report,)Results: Accept [] Reject W Info [] Comments: Un;Percent Of Coverage Obtained > 90%: N/A Re e4 Previous Data: Yes Circtmfer--ntial Orientated Search Unit Calibration Signal Sweep S Paih Reflector Amplitude % 0i4ision* N/A _______________ ulator 8Wock Gin 7Signal BReftector.~ Anplt ude %Dvso 36.0 2" Radius 30 4.00 7.00 able to discern 1/4T Hole in circ. direction. Ekariner Level t- Oa te, Reviewer Signetuit " ODat Hendrickson, Matthew I.. I ii1(82, 0_X arnifner -Level 1I-4 -- i3re ' Cate SiteReview .Signritum Date Griobel, David M. ;;,x.111612010 Other Level NIA, tigna!ure Date ANII Review Sig .ritur, Oate DUKE POWER COMPANY ISI LIMITATION REPORT Component/Weld ID: 3-PDBI-1 Item No: 03.B9.11.0072

remarks: NO SCAN SURFACE -BEAM DIRECTION Procedure allows scanning from Li LIMITED SCAN [-)I N 2 0 1 E3 2 L1 cw Li ccw cast sideonly.FROM L N/A to L N/A INCHES FROM WO CL to Beyond ANGLE: L] 0 L] 45 Z 60 other 70 FROM 0 DEG to 360 DEG L NO SCAN SURFACE BEAM DIRECTION i LIMITED SCAN Li 1 Li 2 Li1 nL 2 Li cw Li ccw FROM L to L INCHES FROM WO to .....ANGLE: L] 0 C] 45 [] 60 other FROM DEG'to DEG Li NO SCAN SURFACE BEAM DIRECTION ED LIMITED SCAN Li I 2 1 n 2 Licw [ccw I FROM L to L INCHES FROM WO to ANGLE: L] 0 L] 45 Li 60 other FROM, ..DEGto __ DEG Li NO SCAN SURFACE BEAM DIRECTION[L LIMITED SCAN i 1 EL 2 L] 1 i ] 2 L cw n ccw UT-10-650 FROM L to L INCHES FROM WO to Sketch(s) attached ANGLE: Li 0 [L 45 Li 60 other FROM DEGto DEG [ yes Li No Prepared By: David Griebef,.- Level: t Date: 11/06/10 Sheet 3' of 4 Reviewed By: Date: /7f ~ At~ie nspector Dalte:

Supplemental Report Report No.: Page: PAGE -7t j6?UT..10-650 4 of 4 Date: &Date: _____Date: 11. jbi.Summary No.: 03..B9.11.10012 -Examiner: Hendrickson, Matthew Examiner: Grieb&6DavlidM. A .- Level; 11-N Other: NJIA Level: N(A Reviewer: Site Review: ANII Review: h-J(A Comments: Best effort exam using 60*RL &. 70'RL per NOE 830 for upper 213 area of Interest I______-,Z2U1)7R-i52- .-2 i -Site/Unit: Summary No.: Workscope: UT Calibration/L._ amination Oconee 1 3 03.C5.21.0034 Procedure: Procedure Rev.: Work Order No.: PDI-UT-2 Repori No.., UT-10-50 page: 1 I c: 01889593 Code: 1998/71;z y ý ,.. atJitV'ei: C-F-11Ct.21 Location: Aux Bldg.Drawing No.: 3HP-365

Description:

Valve 3HP-27 to Elbow.System ID: 51A Component ID: 3HP-386.40 Size/Length: N/A Thickness/Diameter: 0.67414.0JSS Limitations: Yes -See attached sheets Start Time: 1008 Finish Time: 1010 Instrument Seftings Search Unit Cal. Time Date Serial No.: 00X14L Serial No.: SB0253 Checks ___- ---Manufacturer:. KRAUTKRAMER" Manufacturer-KA Initial.Cal 0910 1011412010 Model: USN-60 Size: *. 0.25f" Shape: Round Inter. Cal. _ 1 _Delay: 5.4594 Range: 20 Freq.: 2.25 MHz Style: Comp -G Inter. Cal. l1os 1011412010 M'U Cal/Vel: .1234. Pulser: High Exam Angle: 35 #of Elements: SIngle Inter. Cal.Damping: 1K Reject: 0% Mode: Shear F Ca 13 6 1W1 ;;201 Rep. Rate: Autchigh Freq.: 2.25 Measured Angle: _3_ _ 1 Couplant Filter: Fixed Mode: PE Wedge Style: MSWQC Cal. Batch: 09325 Voltage: Fixed Other. Fullwave Type: ULTRAGEL II Ax. Gain (dB): N/A Circ. Gain (dB): 38,2 Search Unit Cable Mfg.: SONOTECH 1 Screen Div. = 0.2- in. of Sound Path Type: RG -174 Exam Batch 09325 Linearity Report No.: L-104107 Length: 6. No. Conn.: 0 Type: ULTRAGEL It Calibratinn Block Scan Coverage Mfg.: SONOTECH Axial Orientated Search Unit Coibration Sipnaýl Sound Path Rlector Arnpittide % 0ivision NA 1 j____ ____Circumferential Orientated Search Unit ,Calibtatiorr Signl Swe Reflector Amrritude%. DiVi~in 1 Svunds iat 0.75" 1D Nbtch 8o 4.6 ..___'Reference/Simulator Block Cal. Block No. PDI-UT-2A-O Thickness .375 -1.25" Dia.: Flat Cal. Bik. Temp. 76 Temp. Tool: MCNDE40132 Comp. Temp. 82 Temp. Tool: MCNDE40132 Upstream [] Downstream E] Scan dB: NIA CW Sa CCW W Scan dB: 44.2 Exam Surface: o.0.Surface Condition: As Ground Reference Block Serial No.: 04-8744 Type: ROMPAS dB l.Reflector .Amplitudfe % Sound Path! .0 1' Ra~du so 1 4.6 .a-1 0 Recordable Indication(s): Yes El No [ (If Yes, Ref. Attached Ultrasonic Indication Report.)Results: Accept C] Reject 0] info 0]Percent Of Coverage Obtained -90%: No Reviewed Previous Data: Yes Comments: Impingment angle 54.9* Summary No.: Workascope: UT Calibrationk-amination Olon" / .3 03.C5.21.00324 Procedure: Procedure Rev.: Work Order No.: PDI-UT-2 WIACHAEUl C-PAGE S 2 ZT(Outage No.: 072 Reporl.No.; UT-1OSO9 Page. 2 of a o188r903 Code:+ " 199 It j ,.(O. Cat/hem: C-F.IIC5.21 Locaton: .Ax Bldg.Drawing No.: 3HP40-5t!

== Description:==

Valve 3HP-27 to Elbow" System ID: 51A Component ID: 3HP-3640 Size/Length: WiA Thickness/Diameter. 0.67414.01SS Limitations:

  • eS -See attached Stat Time: 1013 Finish Time: 1015...Instrument Semnge Searh Unit Cal Tlm .at Axial Orientated Search Unit____o..__

ox,,,____i__..____o_0,____a, +s .. ....._ ....._____°° + ° + I + e ...+Seral No.:. S ,ial No.: ..DD72 -C-helcksrtion ignal oweep °Manufa cture :K G 8 0.2 -Sae Ron Initi.al ot -09a i14 0 Sound Pa-h Manfacurr KAUKRAERManufacturer KBA Italat06104200 Refleptor Aptue% Division moe.UN6 ie i$ Sae ord Itr. cal. I ID,~ to .....4 I ........beg*. 4.5282, ange: 2.0' Ft=: 2.2 SCamp_- ntr " 1012 101102010. M'W Camelh .1245 Pulser High Exam Angle: 45 ... of Elements: Single -- -_iP..... _"_ T Damping: 1K Reject: 0% Mode: SHEAR J.11U1 1011412010 I Rep. Rate: Autohigh Freq.: Z.25 Measured Angie: 45 Couplant ._*_ _ _ _Fllter Fixed Mode: PE Wedge Style: MSWQC Cal. Batch: 0325 Circumferential Orientated Search Unit Voltage: Fixed Other Fullwava Type: ULTRAGEL U Calibratn Signal Sweep o Ax. Gain (d8): 37A Cim. Gain (dB): NIA Search Unit Cable Mfg.:, .SONOTECH Reflector Amplitude % Division Ufd Path I Screen Div. = 0-2, in. of Sound Path Type: RG -174 Exam Batch 09325 NIA Lin"ar*y Report No.: L-10-107 Length. 6! No. Conn.- 0 Type: ULTRAGEL 11 Calibration Block Scan Coverage Mfg.: SONOTECH Cal. Block No. PDI-UT-2A-O Upstream [] Downstream R] Scan dB: 43.2 Re Block Refonce/Simulator Block Thickness .375-1.25 Dia.: Flat CW C] CCW fJ Scan dB: NIA Ga I Signal Swe Sound Path______________ -Serial No.: 0487 .!Rpetrjinrue~DvsinSudPt Cat. B1k. Temp. 78 Temp. Tool: MCHDE40132 Exam Surface: O.D. Type: ROMPAS 31.5 o RAmusl 8 Division Comp. Temp. 82 Temp. Tool: MCNDE40i32 Surface Condition: As Ground 314- ....Recordable Indo.ation(s): Yes n No W (if Yes, Ref. Attached Ultrisonic Indicalion Repodt.)Results: Accept j] Reject 21 Info M Comments: NIA Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes Examiner Level i-gnature Date Reviewr na1urI GriabelI, D a4id[ M. Il-NA 1 Cochran, tonfnle 0. 10K41 2010 Other Level' 1N4A Sagnat Date ANII Review re Date NIA Site/Unit: Summary No.: Workscope: Oconee 1 03.C5.21 .0034 UT Calibration/-arnmination Procedure: Procedure Rev.: Work Order No.: PDI-UT-2 01389593 PAGE OF Outtge. No.: 03-25 Repor No.: UT-10-599 Pace: 3 Of t;Code:,: t: caUitem; C-F-I1iC5.21 Location: Aux Bldg.Drawing No.: 3HP-365

Description:

Valve 3HP-27 to Elbow System ID: 51A Component ID: 3HP-365-40 Size/Length: NIA Thickness/Diameter: 0.67414.OISS Limitations: Yes -See attached ahoets Start rime: 1020 Finish Time: 1026 Instrument Settings Search Unit Cal ime Date Axial Orientated Search Unit Serial No.: 0OX14L Serial No.: OODNL3 Checks , , ,,, Calibt ion S.Signal SS o unp , p , Manufacturer. KRAUTKRAMER Manufacturer. KBA Initial Cal 0912 10/11412010 Rcecicr Amnplitude %Model: USN-60 Size: 0.25 Shape: Round Inter.,Cal. -__ _______ 10 IsNotc 80 &4____ ) 1.35 Delay: 5.5072 Range: 2.r Freq.: 2.25 Style: Comp-G ,nter. Cal. 1019 1011412010 M'd CalVel: .1249 Pulser. High Exam Angle: 60 # of Elements: Single IInter. Cal. ____.... ....... .................. ____Damping: 1K Reject: 0% Moade: SHEAR -Final Cal 1140 011412010 1 Rep. Rate: Autohigh Freq.: 2.25 Measured Angle, 60 Couplant _____, Filter: Fixed Mode: PE. Wedge Style: MSWQC Cal. Batch: ..09325 Circumferential Orientated Search Unit.Voltage: Fixed Other: Fullwave Type: ULTRAGEL II f Cil iornt S~gnel Sweep Ax. Gain (dB): 55.4 Circ. Gain (dB): N/A Search Unit Cable Mfg.: SONOTECH NIeAector Amtlide % , ial pound ttt I Screen Div. .25 in. of Sound Path Type: RG -174 Exam Batch 09325 NIA _Lineanty Report No.: L-10-107 Length: 6- No. Conn.: -Type: ULTRAGEL II Calibration Block Scan Coverage Mfg.: SONOTECH I Cal. Block No. PDI-UT-2A-O Upstream C3 Downstream 2 Scan dB: 55.4 Reference Block RaferenceSinulator Block Thickness .375-1.25 Dia.: Flat CW C3 CCWfJ Scan dB: NIA Gain Signal e % P', Sound Path________ ___________ -Serial No.: 04-8744 dS Reflector Amplitude 'A Divsion Cal. Blk. Temp. 76 Temp. Tool: MCNDE40132 Exam Surface: 0.0 Type: ROMPAS 35.s JI- R jusI 80so 4.0 1 IX-Comp. Temp. 87 Temp. Tool: MCNDE.40132 Surface Condition: As Ground Recordable Indication(s): Yes No jGj (If Yes, Ref. Attached Ultrasonic Indication Report.)Results: Accept E Reject 0 Info Comments: N/A Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes ....Examniner Level Il~li Dote Reviewer 'Djgntr aleJ Griebel. David M. 10114F7010 Examiner Level IM4 ,~ signatiedw Date site' Review Signrture Ot-ora.Lonnie D. ~ .LL. ~10/1412010 Other Level NIA Dateatuw Itl Rview Dl NIA -' SiteiUnit: Summary No.: Workscope: UT Calibration/L amination Oconee I 3 03.C5.21.0034 IS'Procedure: Procedure Rev.: Work Order No.: PDI-UT02 AT TACHMENT PA E T OF Outage No.: O3-25 Report No.: UT-10-509 Page: 4 of 8 Aux Bldg.01889593 Code: 1900t Drawing No.: 3HP-365 System ID: 51,A Component ID: 3HP-365-40 Limitations: Yes -See attached shoets r'w 4 J&ý174-1& Cat./lte Dm n C-Fa-ICS.21

== Description:==

Valvo 3HP-27 to Elbow Location.Size/Length: NtA Start Time: 1216 Thickness/Diameter: 0.67414.0iSS Finish Time: 1225 Instrument Settings Search Unit Cal-. Time Date Serial No.: 0DX14L Serial No.: 10-1213. Checks Manufacturer:. KRAUTKRAMER Manufacturer: RTD iitial Ca0l 840 .0..201 Model: USN-60 Saie: 2(BX14) Shape: Roet.. inter. Cal. _Delay: 8.2028 Range: 2.5 Freq.: 2.0 Mkz. Style: TRL 2 inter. Cat. 1215 ..122010 Mil Ca/Vel: .2319 Pulser High Exam Angle 60 0 of Elemrents: Dual Inter. Cal.Damping: 1K Reject: 0% Mode: Longg. Final Cal 1410 1012012010 Rap. Rate: Autohlgh Freq.: 2.0 Measured Angle: 60 Couplant Filter. Fixed Mode: Dual Wedge Style: Integral Cal. Balch: .09325 Voltage: Fixed Other: Fullwave Type: ULTRAGEL HI Ax. Gain (dB): 53.4 Cirm. Gain (dB): NIA Search Unit Cable Mfg.: SONOTECH I Screen Div. = .25 in. of Sound Path Type: RG -174 Exam Batch 09325 Linearity Report No.: L-10-107 Length: 6. No. Conn.: 0 Type: ULTRAGEL II Calibration Block Scan Coverage Mfg.: SONOTECH Cal. Block No. 8279-0412 Upstream F1 Downstream R] Scan dB: 53.4 Reference Block Thickness 0.674 Dia.: 4.5 CW [] CCW n Scan dB: NIA Serial No.: 8279-0407 Cal. BIk. Temp. 75 Temp. Tool: MCNDE40130 Exam Surface: O.D Type: DSC Comp. Temp. 87 Temp. Tool: MCNOE4oi3O Surface Condition: As Ground Recordable Indication(s): Yes E] No [] (If Yes. Ref. Attached Ultrasonic Indication Report.)Results: Accept [] Reject [,] Info C] Comments: Trai Sound Path 1.2 Circumferential Orientated Search Unit fCalibmiation fSignal 1Swoep gZ Reflector Amplitude % Division Sn Ph ReferencelSimulator Block Gain S igns! SweeP Sound Path dS, Relector lAinflvdO %1 DivisiO.3 .8 f 2-0 I so 8.0 2.00.nsducer specs FS-25mmlOD 5' Ax.Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes=Eamniner Level lI.N Signature Date Revieweir a t D Cochran, Lonnie O, " ...... ,....Exmnr Level 11-.N /)' l~ure Date, Site Review Dineer.r.ibel, David M. 1012012010 Other Level NIA / Stgniture DaeANVi Review v~ Date: N ,A o o"" V (......~7 4F C PAl 6 ~ (1 I DUKE POWER COMPANY ISI LIMITATION REPORT Component/Weld ID: 3HP-365-40 Item No: 03.C5.21.0034 remarks: NO SCAN SURFACE BEAM DIRECTION Due to valve to elbow 33 LIMITED SCAN [] 1 [ 2 1 1 [] 2 33 cw 33 ccw configuration: FROM L ._I to L INCHES FROM WO CL to Beyond ANGLE: 33 0 0 45 Z 60 other FROM 0 DEG to 360 DEG Z NO SCAN SURFACE BEAM DIRECTION Due to valve to elbow 33 LIMITED SCAN 33 1 E 2 33 1 33 2 [0 cw Z ccw configuration. FROM L .to L INCHES FROM WO CL to Beyond _ANGLE: 33 0 3] 45 3] 60 other 35° FROM 0 DEG to 360 DEG 33 NO SCAN SURFACE BEAM DIRECTION _33LIMITED SCAN 3 1 3] 2 3 1 [] 2 cw 3 ccw 1 FROM L to L INCHES FROM WO to ....... i ANGLE: 3 0 3 45 3360 other FROM, DEG to DEG 33 NO SCAN 33 LIMITED SCAN FROM L t_ANGLE: 33 0 33 4 SURFAI\CE BEAM DIRECTION 71 2 331 [3 2 0 cw 03 cvw INCHES FROM WO to FROM DEG to DEC UT-1 0-509 Sketch(s) attached o L t5 [] 6.0 other 4ýSupplemential Report RepotlN. UT-10-509 Page: 6 of 8 Summary No.: 03.C5.21.0034 Examiner: GNrebelDavidM. Examiner: Cochran. Lonnie D. 4 Oth'er: N/A Level: 1l-N Level: I1-N Level: NIA Reviewer: Site Review: ANII Review, Date: Date: Comments: Profile and thickness Sketch or Photo: ,-/I I I1 I (Ki/,vL ,7 I Supplemental Report AITACHME I f Report No.: UT4i0-509 Page: 7 of 8 Summary No.: 03.C5.21.0034 Examiner: Griebef. Oavid M. <Examiner: Cochran, Lonnie 0. Other: NIA Levd. 11-N Levei: il-N Level: NIA Reviewer, Site Review.ANII Review: Date~Date Date: 44 ~ TL~I Comments: Scan limitation due to valve 3HP-027-== Z--hv,.I LW?? I/V iV41L /, Sketch or Photo:-5-4 P.-uJý -Du~r t~LM-C Sitef Unit: 0c Determination of Percent Coverage for UT Examinations -Pipe ones, 3 Summary No.: 03.CS.21.0034 Workscope: ISI Procedure: Procedure Rev.: Work Order No.: PDI-UT-2 E0 01889593 Outage No.: 03-25 Report No.: UT.10-509 Page: 8 of 8 Scan I % Length X % volume of length / 100 =Scan 2 % Length X % volume of length / 00 =Scan 3 100.000 % Length X 50.000 % volume of length I 100 =Scan 4 100.000 % Length X 50.000 % volume of length / 100 =% total for Scan I% total for Scan 2 50.000 % total for Scan 3 50.000 % total for Scan 4 Add totals and divide by# scans a% total for 45 deg Other don -60 (to be used for supplemental scans)The data to be listed below Is for coverage that was not obtained with the 45 dog scans.Scan 1 100.000 Scan 2 100.000 Scan 3 Scan 4% Length X 50.000% Length X 0.000% Length X% Length X" volume of length / 100 =% volume of length (100 =% volume of length I 100 =% volume of length /100 =50.000 % total for Scan 1 0.000 % total (or Scan 2" total for Scan 3% total for Scan 4 Percent comalete coveraae Add totals for each scan required and divide by # of scans to determine; _ % Total for complete exam Site Field Superv sor 2.d / V14 Pate: __ _ _ _ ~e y Site/Unit: Summiary No.: Worksope: UT Calibration Oconee / 3 03.CS.21.0086 p amination Procedure: rocedure Rev.: ork Order No.: PDI-UT-2 A1 A HME41 PA 5E ý7g Of 3 Outage No.: 03-25 Report No-: UT-1O-513 pagto I of 6.B 01889598 Code: 1998/ZOOOA CatItem: C-F-liCS.21 Location: Aux Bldg Drawing No.: 3HP.8 Description; Reducer to Pipe System ID: SIA Component ID: 3HP-498-14 S4 Size/Length: N/A ThicknessfDiameter: 0.43612.01SS Limitations: Yes -See attached sheets Start Time: 0916 Finish Time: 0933 Instrument Settngs Search Unit Cal. Tim Sat A t rinsedSach Unit Seriat No-: 0OXI4L Serial Nat.: 80 Checks ____ airto we '~ 't Manufacturer: KRAUTKRAMER Manufactur er: IKAInitial Cal. 0634 ý10/21/2010 f r 'A'i -I clso un R.Delay: 4.5262 Range: 1.V' " Frea. 2, .Style- Cornp-G Inter. Cal. 0915 10/212.2010 Model:.1K. .SN-60 Sir..: .25 Shape: R * ...'. 01 o M'l CalNel: .1245 Pulser: High Exam Ane: 4 #4 of Elements: Single Inter. Cal. " ... .... .Damping: 1_ K Reject: 0% Mode: Shear t _ Cal; .. 10 -Rep. Rate: Autobigh Freq.: 21S25 Measured Angle: ASCouplant__________ Filter Fixed Mode: PE Wedge Style: CCal. Batch: 09325 .r Un i Voltage: Fixed Other: Fullwave Type: ULTRAGEL II Calibration Signal Swep Ax. Gain (dB): 32.3 Circ. Gain (dB): NIA Search Unit Cable Mfg.: SONOTECH j Arn pitude% d i;viior eowx. !Lineatily Report No.: L-10-107 Length: 6' No. Conn.: 0- Type: ULTRAGEL If Calibration Block Scan Coverage Mfg.: SONOTECH .Cal. Block No.:, PDI-UT-2A-O Upstream C DownstreamF41 Scan dB: 38.3 Reference Block Refeorc,:emutStor Blockr Thickness: .375-1.25" Dia.: Flat CW[1 Scan dB:l N/A e4in Seo, e I Swee,__________________ _ -~~Serial Na,: 04-8737 RetcoAmioIOiin Cal. Bik. Temp.: 71 Temp, Tool: MCNOE4O Exam Surface: O.0. Type: ROMPAS 27.0 V 80 7 s.i to0 Comp. Temp.: 87 Temp. Tool: MCNDE40132 Surface Condition: As Ground ________-_._ _____ ....__--_ --_Recordable Indication(s): Yes N No VL (If Yes, Ref. Attached Ultrasonic Indication Report.)Results: Accept F] Reject f Info J Comments: N/A Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes I Examiner ~~vo1 ~ ) lure Date ee r(Sitaie Qr~e aid 1.-1012112C1 /~ [Examiner Level ti-N Cochran, Lonnie D, ._.. :0t!21: OtherL .A. Date Sl *S__ _ _ _ _ _ __ _ _ _ _ _ __ _ _ _ A V t , ..... Site/Unit Summary No.: Workscope: UT Calibration aamination Oconee t1 3 03.CS.21.0066 IS1 Procedure: Procedure Rev.: Work Order No.: POI-UT-2 At 1ACHMENT C-Outage No.ý s?Report No-: UT-1"-13 Page: 2 of E o1a11s69 Code: 1998B1000A Catitem: C#-lC5.21 Loc ation: Aux Bldg Drawing No.: .3HP-498 Descriptlon: Reducer t. Pipe System ID: 51A Component ID: 3HP-428-14 $S1ze/Length: N/A ThidcessIDIameter. 0.43512.0ISS Umhlallona: Y !ta See attached che.t. Start Time: 0936 Finish Time: 0942 Instrumerd Setting* sernch Unit CA. 1ime Date AxI Orientated Search Unit Serial No.,: OX14L. Seria. to.: :..... I Cec.. -. Camii-o Signal S Sound Path Manuatuer. FixedKA~t MoeinWig tliMSQ .... a.ti h 92 ... !cmaeal Craentate SuohUnitd~ anuaerK- ,,,Manufacturer: -jtk 16M110 Reflior AmpIde O Division Dam.Ging(e: 1K? Cr.Gan(B / Reee:arod: hEARn~ -al Mg: SOOE____r___~itie% un a Mdel n U.st,2 n size. 0.25' Shape: Round Paterh Cal. yoech ..-_ch _____ __1.Delay. 5.Bl 7106 Range'. 2.00 Freq.- Co p iter. Cal. 093N TC/21H2 1 Cal W elo .1246 PuIser. High Exam Angle: o o of Elements: S1,igle ofr. Cal, 1 ,103 Rap. Rate: Autohigh Fec 2.o Measured Angie: 80nCouprantk Filter. Fixed Mode* PE Wedge Style: MS 1WQC Cal. Batch: 09325 Circumfearenttal Orientated Search Unit Voltage: Fixed Other FuitWave Type: .ULTRAGEL II Calibration signal, Sweep Ax. Gain (dB): 55.7 Ch,2 Gain (dBFt NIA Search Unit Cable M1i10. SONOTECH Renector Amplitude % Olvslon tSnd Path C Saremen Div. 1 -2 in. of Sound Path Type-, : RG Exa: Batch,,132. NIX..,____ h Unearity Report No.: L-10-107 Length: 6 No. Conn.: .___T: REi Calibration Block Scan Coverage Mfg: SoNtOTECH Cal. Block No. ... Upstream Downstream Sean dB: 81.7 Thickness .3" P1J! Di.: Flat CW 0.CCW C. Scan dB: NIA S No.: 04473 Gain Signal Sweep 'Sound Path Ca______________ Ti Tem.T___________xaSrfae:OX dB Refllctor Ampltude % Divison Cal 5k.Tep.71 em. oo: CND4O3O ~ m ~ _____________Type: ROMPAS -. I' Radius .80 .5.0 1.00 Comp. Temp. 87 Temp. Tool: MCNOE40132 Surface Condition: As Ground Recordable Indication(s): Yes F1 No (11 Yes. Ref. Attached Ultrasonic Indication Report.)Results: Accept C) Reject R) info [] Comments:. NIA Percent Of Coeq g Obtained 90%: No Reviewed Praylous Dare:, Yeis E aiet Leve4l lN Data ýRelvewer oS~at*Dt drll, Daivid M. :. 111121/201160IAic Exiainerar cave] f sign Turte Date Siitedw, Re~r wat Cochrain, Lonnihi 0.DL-.-.- 1012112010 'Othee LevlN/ASinaur Date AýNII'Review ale N/A V. -f 4 Site/Unit: Summary No.: Workscope: UT Cal ibration/L.-amni nation Oconee / 3 03.C5.21.0066 'Ii Procedure: Procedure Rev.: Work Order No.: PDI-UT-2 AlI 1AEHM N T Outage No.: 03-25 Report No.: UT-10-513 Page: 3 Of 01889598 Code: 199812000A Catilltem: C-F-11C5.21 Location: Aux Bldg Drawing No.: 3HP-498

Description:

Reducer to Pipe System ID: 51A Component 0D: 3HP-498-14 Size/Length: N/A Thickness/Diameter: 0.43612.01SS Limitations: None Start Time: 1632 Finish Time: 1640 Instrument Settings Search Unit Cal. Axial Orientated S.arch Unit Serial No.: 0OX14L Serial No.: 014XD9 Checks I Calibration Signal Sweep Sound Path Manufacturer: KRAUTKRAMER Manufacturer KBA Inital Cal. 1417 10-2812010, Reflector Amplitude % 1 Division Model: USN-60 Size: 0.23 Shape: Round lt~ a. _____________- _____ " Notch 80 7.8 1 1.97 Delay: 7.0688 Range: 2.5 Freq.: 2.25 MHz Style: Comp-G inter. Cal. 1630 10.2812010 M'tl Cal/el: .1263 Pulser: High Exam Angle: 70 # of Elements: Single Inter. Cal. 'Damping: 1K Reject: 0% Mods: Shear .-Final-Cal. 1806 10W128212010 Rep. Rate: Autohigh Freq.: 2.25 Measured Angle: 70 Couplant___ Filter: Fixed Mode: PE Wedge Style: MSWQC Cal. Batch: 09325 Circumferential Orientated Search Unit Voltage: Fixed Other: Fullwavo Type: ULTRAGEL III Calibration Signal Sweep Ax. Gain (dB): 66.8 Circ. Gain (dB): NIA Search Unit Cable Mfg.: SONOTECH Reflector Amplitude % Division 1 Sound Path--1 Screen Div. = .25 in. of Sound Path Type: .RG -174 NIAExam Batch: 09325 A _ _ _ _.... .Linearity Report No.: L-10-107 Length: 6. No. Conn.: 1 Type: ULTRAGEL II -_ _Calibration Block Scan Coverage Mfg.: SONOTECH .*Cal. Block No.: P0I-UT-2A-O Upstream v Downstream[] Scan dB: 66.8 Reference Block Reference/Simulator Block Thickness: .375-1.25 Dia.: Flat CWW CCWE Scan dB: N/A Serial No.: 0"744 Gain Signal Sweep Sound Path-Seial o.:. 04744 d8 Reflector .Arnolituide % IDivision SonI Pt Cal. Bik. Temp.: 71 Temp. Tool: MCNOE40130 Exam Surface: 0.0 Type: ROMPAS 49.0 i" Radlulý 80 4.1 1.00 Comp. Temp.: 85 Temp. Tool: MCNDE40130 Surface Condition: As Ground Recordable Indication(s): Yes -1 No _3 (If Yes. Ref. Attached Ultrasonic Indication Report.) .Results: Accept 0J Reject V: llo Comments: Supplemental 70' used for single sided access Percent Of Coverage Obtained > 90%: No Reviewe" Previous ODate Yes Exaeriiiier Level ll.N ..,igaueDale Revievveri aiijr&Cochran, Lonnie 0. A 10f=82010 Other Level NIA Signature Datej ANtI ReviowqI NIA 4. .: K E -SitelUnit: Summrary No.: Workscope: UT Cafibrafionhk--amination Oconee / 3 03.CS.2.1.0066 Isl Procedure: Procedure Rev,: Work Order No.: PDI-UT-2 E 01889598 AI IACHMENITC P A GE 6eT D Fr~Outage No.: 03-25 Report No.: LUT-10-513 Page: 4 of 6 Code: 199812000A, Cat./ltem: C-F-41C5.21 Location: Aux Bldg Drawing No.: 3HP-49B

Description:

Reducer to Pipe System ID: 51A.Component ID: 3HP-49.-14 Siz"S Leng.h: MIA Thickness/Diameter: 0.436J2.OSS Limitations: Yes -See attached sheet Start Time: 0904 Finish Time: 0914 Instrument Settngs"earch Unit Serial No.: 0OX14L 0ertai No: 00D72, Manufacturer: KRAUTKRAMER Manufacturer: KSA Model: Size: 0.25 Shape: Round Delay: 3.4019 Range: 2.00 Freq.:- 2.25 MRZ Style: Camp -G M'11 CaUVet: .1220 Pulser: High Exam Angle: 30 # of Elements: Single Damping: 1K Rejec:: 0% Mode: SHEAR Rep. Rate: Autohigh Freq,: 2.25 Measured Angle: 30 Filter: Fixed Mode: PE Wedge Style: MSWQC Voltage: Fixed Other Fullwave Ax. Gain (dB): NIA Circ. Gain (dB): 39.4 Search Unit Cable I Screen Div. = .2 in. of Sound Path Type: RG -174 Linearity Report No.: L-10-107 Length: 6- No. Conn.: 0 Calibration Block Scan Coverage Cal. Block No.: PDI-UT-2A-O Upstream [ DownstreamE] Scan dB: NIA Thickness: .375" -1.25& Dia.: Fiat CWR CCWgJ Scan dB: 35.4 Cal. BIk. Temp,: 71 Temp. Toot: .MCNOE4OI30 Exam Surface: O.D.Comp. Temp.: 87 Temp. Toot: MCNDE40132 Surface Condition: As Ground Cal. f Time D uate Checks I I ..Initial Cal. 0630 10/2112010 Inter. Cal. .i Inter. Cal. 0903 10/2112010 In t e r. C a l. -1 Final Cal. 1035 1012112010 Couplant Cal. Batch: 09325 Type: ULTRAGEL It Mfg.: SONOTECH Exam Batch: 09325 Type: ULTRAGEL II Mfg.: SONOTECH.Reference Block Serial No,: 04-8737 Type: ROMPAS Axial Orientated Search Unit Cairtn Signal Swee Sound Path Ref'e2tcr Amplitude % Division.7S Notch 0o 4X6 .961 Circumferential ietedSrhUt Calibration Signal SvwleaP Reflecto'Rre Ampnel% s D 1,,'oSound Path Ulatdr Bl'ockI I wain Sigial ;sweep...dB Reflector I Amplitude'% Ohis Sound Path 30.0 1" Radius so 5.0 1.00 Recordable Indication(s): Yes 0 No [ (If Yes, Ref. Attached Ultrasonic Indication Report.)Results: Accept (D Reject i] Info 0 Percent Of Coverage Obtained > 90%: No Reviewed Previous Data: Yes Comments: Impingement angle 62' AIIACHMENi (DUKE POWER COMPANY ISI LIMITATION REPORT Component/Weld ID: 3HP-498-14 Item No: 03.C5.21.0066 remarks:[] NO SCAN SURFACE BEAM DIRECTION Limited scan due to reducer[ LIMITED SCAN Li 1 [ 2 N I ni 2 [:1 cw El ccw configuration. FROM L N/A to L N/A INCHES FROM WO .7" to Beyond ANGLE: 0 0 0 45 0 60 other FROM 0 DEGto 360 DEG 0 NO SCAN SURFACE BEAM DIRECTION LILIMITED SCAN Li1 02 i1 [ 2 L cw [] ccw FROM L 'to L INCHES FROM WO to ANGLE: 0] 0 045 060 -other FROM DEG to DEG Li NO SCAN SURFACE BEAM DIRECTION O LIMITED SCAN 01 [112 0i 1 2 2] cw [ccw FROM L to L INCHES FROM WO to _ANGLE: Li 0 Li 45 Ei 60 other FROM DEG tb DEG Li NO SCAN SURFACE BEAM DIRECTION Li LIMITED SCAN 0 I Li 2 Li1 [L 2 Li Cw Li ccw UT-10-513 FROM L to L INCHES FROM WO to Sketch(s) attached ANGLE: 0] 0 [] 45 0] 60 other FROM __ DEGto, _ DEG Ayes L No PrePea .By' David Griebel ,Level: it Date: 10/2,110 s 1 5_ _Reviewed By: Date: Date:/" C , I AxialS(tern No. 03.C521.0(66 'Coverage of Vol urne Claimed 30.45% for Scan 2 ILI CIvr'Weld Nu4 3iHP-498-14 Pipe-Si Gr Scan Coverage Reducer-S2 Coverage of Volume Claimed =100% for Scan 3&4 Pipe-SI Scale: I"= " Inspector I Date: )(_ ' .t-Page ('}}