CONSUMERS POWER COMPANY PALISADES PLANT -DOCKET 50-255 -LICENSE DPR-20 PROPOSED TECHNICAL SPECIFICATIONS CHANGE REQUEST PROPOSED PAGES /! 1 PAGE p 000255 . PDR MI0583-0016B-NL02 TABLE 4. 3.2 -----*--------------------------Misceu-a-neous Stirveillance--ifems Equipment Method Frequency

1. Regenerative Heat Exchanger
a. Primary Side Shell to Tube Sheet Welds Volumetric 5-Year Maximum Interval (100%) b. Primary Head Volumetric Year Maximum Interval (100%) 2. Primary Coolant Pump Flywheels Volumetric 100% Upper Flywheel Each Refueling TABLE 4.3.3 Reactor Vessel Surveillance Coupon Removal Schedule Capsule Refueling Number Capsule 1 Target Removal Time Number Primary -Optional Location EFPY @ Refuel No A-240 2 Outside Core Barrel 2.26 @ 23 W-290 5 11 Vessel Wall 4.33 @ 5 T-330 5 20 Above Core 4.33 @ 5 W-110 11 5 Vessel Wall 9.21 *@ 11 W-100 20 25 Vessel Wall 16.5 @ 20 T-150 20 5
  • Above Core 16'.5 @ 20 W-280 25 -20 Vessel Wall 20.6 @ 25 W-260 35 39 Vessel Wall 28.7 @ 35 W-80 39 35 Vessel Wall 32.0 @ 39 1 Refer to Pafisades FSAR, Volume 2, Section 4.5.3, Figure 11 for illustration of capsule locations.

2 EFPY based on 2530 MWt power rating. 3 2.26 EFPY from BCL 585-12 Report, March 13, 1979. nu0583-0248a-43-71 4-23 PROPOSED 2 I I l . I I l ! I ; I I I I I