Proposed TS Table 4.3.2 Re Miscellaneous Surveillance Items
ML18065A863
Person / Time
Site: Palisades Entergy icon.png
Issue date: 08/14/1996
From:
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
Shared Package
ML18065A862 List:
References
NUDOCS 9608200005
Download: ML18065A863 (4)


Text

ATTACHMENT 1 CONSUMERSPOWERCOMPANY PALISADES PLANT DOCKET 50-255 TECHNICAL SPECIFICATIONS CHANGE REQUEST ONE TIME FREQUENCY EXTENSION LICENSE DPR-20 PRIMARY COOLANT PUMP FLYWHEEL INSPECTIONS Proposed Page 1 Page

--96tf8200005-960814 PDR ADOCK 05000255 p

PDR

TABLE 4.3.2 Miscellaneous Surveillance Items Equipment

1.

Regenerative Heat Exchanger

2.
a.

Primary Side Shell to Tube Sheet Welds

b.

Primary Head Primary Coolant Pump Flywheels Method Volumetric Volumetric Volumetric Frequency 5-Year Maximum Interval(l00%)

5-Year Maximum Interval (100%)

100% Upper Flywheel*

Each Refueling

  • The volumetric examination of the upper primary cool ant pump flywheels is not required during the refueli~g outage at the end of cycle 12.

4-23 Amendment No. 34, 19, -142-,

ATTACHMENT 2 CONSUMERS POWER COMPANY PALISADES PLANT DOCKET 50-255 TECHNICAL SPECIFICATIONS CHANGE REQUEST ONE TIME FREQUENCY EXTENSION LICENSE DPR-20 PRIMARY COOLANT PUMP FLYWHEEL INSPECTIONS Current Page Marked to Show Changes 1 Page

TABLE 4.3.2 Miscellaneous Surveillance Items Egui.pment

1.

Regenerative Heat Exchanger

2.
a.

Primary Side Shell to Tube Sheet Welds

b.

Primary Head Primary Coolant Pump Flywheels Method Volumetric Volumetric Volumetric 4-23 Frequency 5-Year Maximum Interval(100%)

5-Year Maximum Interval (100%)

100% Upper Flywheel!

Each Refueling

=

Amendment No. 34, f-9, ~'