ATTACHMENT 1 CONSUMERSPOWERCOMPANY PALISADES PLANT DOCKET 50-255 TECHNICAL SPECIFICATIONS CHANGE REQUEST ONE TIME FREQUENCY EXTENSION LICENSE DPR-20 PRIMARY COOLANT PUMP FLYWHEEL INSPECTIONS Proposed Page 1 Page
--96tf8200005-960814 PDR ADOCK 05000255 p
TABLE 4.3.2 Miscellaneous Surveillance Items Equipment
- 1.
Regenerative Heat Exchanger
- 2.
- a.
Primary Side Shell to Tube Sheet Welds
- b.
Primary Head Primary Coolant Pump Flywheels Method Volumetric Volumetric Volumetric Frequency 5-Year Maximum Interval(l00%)
5-Year Maximum Interval (100%)
100% Upper Flywheel*
Each Refueling
- The volumetric examination of the upper primary cool ant pump flywheels is not required during the refueli~g outage at the end of cycle 12.
4-23 Amendment No. 34, 19, -142-,
ATTACHMENT 2 CONSUMERS POWER COMPANY PALISADES PLANT DOCKET 50-255 TECHNICAL SPECIFICATIONS CHANGE REQUEST ONE TIME FREQUENCY EXTENSION LICENSE DPR-20 PRIMARY COOLANT PUMP FLYWHEEL INSPECTIONS Current Page Marked to Show Changes 1 Page
TABLE 4.3.2 Miscellaneous Surveillance Items Egui.pment
- 1.
Regenerative Heat Exchanger
- 2.
- a.
Primary Side Shell to Tube Sheet Welds
- b.
Primary Head Primary Coolant Pump Flywheels Method Volumetric Volumetric Volumetric 4-23 Frequency 5-Year Maximum Interval(100%)
5-Year Maximum Interval (100%)
100% Upper Flywheel!
Each Refueling
=
Amendment No. 34, f-9, ~'