{{#Wiki_filter:Constellation Energyr Nine Mile Point Nuclear Station P.O. Box 63 Lycoming, NY 13093 February 27, 2006 U. S. Nuclear Regulatory Commission Washington, DC 20555-0001 ATTENTION:
{{#Wiki_filter:Constellation Energyr                                                   P.O. Box 63 Lycoming, NY 13093 Nine Mile Point Nuclear Station February 27, 2006 U. S. Nuclear Regulatory Commission Washington, DC 20555-0001 ATTENTION:           Document Control Desk


==SUBJECT:==
==SUBJECT:==
Document Control Desk Nine Mile Point Nuclear Station Unit No. 1; Docket No. 50-220 Special Report: Channel #11 of the Containment Hydrogen Monitoring System Inoperable for Planned Preventive Maintenance In accordance with Action 4.a of Nine Mile Point Unit I Technical Specification Table 3.6.11-2,"Accident Monitoring Instrumentation Action Statements," Nine Mile Point Nuclear Station, LLC, is submitting the following Special Report concerning inoperability of Channel #11 of the Containment Hydrogen Monitoring (CHM) System.Description of Event On February 13, 2006, at 0844 hours, operators declared Channel #11 of the CHM System inoperable to perform planned preventive maintenance.
Nine Mile Point Nuclear Station Unit No. 1; Docket No. 50-220 Special Report: Channel #11 of the Containment Hydrogen Monitoring System Inoperable for Planned Preventive Maintenance In accordance with Action 4.a of Nine Mile Point Unit I Technical Specification Table 3.6.11-2, "Accident Monitoring Instrumentation Action Statements," Nine Mile Point Nuclear Station, LLC, is submitting the following Special Report concerning inoperability of Channel #11 of the Containment Hydrogen Monitoring (CHM) System.
Cause of Inoperabifitv Channel # 11 of the CHM System was removed from service to support planned preventive maintenance.
Description ofEvent On February 13, 2006, at 0844 hours, operators declared Channel #11 of the CHM System inoperable to perform planned preventive maintenance.
Maintenance activities included component replacements required on one, two and ten year frequencies.
Cause of Inoperabifitv Channel #11 of the CHM System was removed from service to support planned preventive maintenance. Maintenance activities included component replacements required on one, two and ten year frequencies.
Channel # 12 of the CHM System was verified to be operable prior to removing Channel #11 from service.Actions Taken Maintenance was completed, surveillance testing was performed satisfactorily and Channel #11 of the CHM System was restored to operable status on February 17, 2006, at 1400 hours.Should you have any questions regarding this submittal, please contact M. H. Miller, Licensing Director, at (315) 349-1510._;_1 Document Control Desk February 27, 2006 Page 2 Sincerely,'Jaames A. Hutton Plant General Manager JAH/RF/sac cc: S. J. Collins, NRC Regional Administrator, Region I L. M. Cline, NRC Senior Resident Inspector Document Control Desk February 27, 2006 Page 3 bcc: T. J. O'Connor J. A. Hutton T. Syrell M. H. Miller NMPIL 2029 COMMITMENTS IDENTIFIED IN THIS CORRESPONDENCE:
Channel # 12 of the CHM System was verified to be operable prior to removing Channel #11 from service.
* NONE Posting Requirements for Responses  
Actions Taken Maintenance was completed, surveillance testing was performed satisfactorily and Channel #11 of the CHM System was restored to operable status on February 17, 2006, at 1400 hours.
-NOV/Order No}}
Should you have any questions regarding this submittal, please contact M. H. Miller, Licensing Director, at (315) 349-1510.
_;_1
 
Document Control Desk February 27, 2006 Page 2 Sincerely,
                                                      'Jaames A. Hutton Plant General Manager JAH/RF/sac cc:     S. J. Collins, NRC Regional Administrator, Region I L. M. Cline, NRC Senior Resident Inspector
 
Document Control Desk February 27, 2006 Page 3 bcc:   T. J. O'Connor J. A. Hutton T. Syrell M. H. Miller NMPIL 2029 COMMITMENTS IDENTIFIED IN THIS CORRESPONDENCE:
* NONE PostingRequirementsfor Responses - NOV/Order No}}

Latest revision as of 21:20, 23 November 2019

Special Report: Channel #11 of the Containment Hydrogen Monitoring System Inoperable for Planned Preventive Maintenance
ML060670363
Person / Time
Site: Nine Mile Point Constellation icon.png
Issue date: 02/27/2006
From: Hutton J
Constellation Energy Group
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML060670363 (3)


Text

Constellation Energyr P.O. Box 63 Lycoming, NY 13093 Nine Mile Point Nuclear Station February 27, 2006 U. S. Nuclear Regulatory Commission Washington, DC 20555-0001 ATTENTION: Document Control Desk

SUBJECT:

Nine Mile Point Nuclear Station Unit No. 1; Docket No. 50-220 Special Report: Channel #11 of the Containment Hydrogen Monitoring System Inoperable for Planned Preventive Maintenance In accordance with Action 4.a of Nine Mile Point Unit I Technical Specification Table 3.6.11-2, "Accident Monitoring Instrumentation Action Statements," Nine Mile Point Nuclear Station, LLC, is submitting the following Special Report concerning inoperability of Channel #11 of the Containment Hydrogen Monitoring (CHM) System.

Description ofEvent On February 13, 2006, at 0844 hours0.00977 days <br />0.234 hours <br />0.0014 weeks <br />3.21142e-4 months <br />, operators declared Channel #11 of the CHM System inoperable to perform planned preventive maintenance.

Cause of Inoperabifitv Channel #11 of the CHM System was removed from service to support planned preventive maintenance. Maintenance activities included component replacements required on one, two and ten year frequencies.

Channel # 12 of the CHM System was verified to be operable prior to removing Channel #11 from service.

Actions Taken Maintenance was completed, surveillance testing was performed satisfactorily and Channel #11 of the CHM System was restored to operable status on February 17, 2006, at 1400 hours0.0162 days <br />0.389 hours <br />0.00231 weeks <br />5.327e-4 months <br />.

Should you have any questions regarding this submittal, please contact M. H. Miller, Licensing Director, at (315) 349-1510.

_;_1

Document Control Desk February 27, 2006 Page 2 Sincerely,

'Jaames A. Hutton Plant General Manager JAH/RF/sac cc: S. J. Collins, NRC Regional Administrator, Region I L. M. Cline, NRC Senior Resident Inspector

Document Control Desk February 27, 2006 Page 3 bcc: T. J. O'Connor J. A. Hutton T. Syrell M. H. Miller NMPIL 2029 COMMITMENTS IDENTIFIED IN THIS CORRESPONDENCE:

  • NONE PostingRequirementsfor Responses - NOV/Order No