Constellation Energy Nine Mile Point Nuclear Station P.O. Box 63 Lycoming, NY 13093 April 21, 2009 U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 ATTENTION:

SUBJECT:

Document Control Desk Nine Mile Point Nuclear Station Unit No. 1; Docket No. 50-220 Core Operating Limits Report Enclosed is a copy of the Core Operating Limits Report, COLRI-19, Revision 0, for Nine Mile Point Unit 1 (NMP1). This report is being submitted pursuant to NMP1 Technical Specification 6.6.5.d.

Should you have any questions regarding the information in this submittal, please contact T. F. Syrell, Director Licensing, at (315) 349-5219.

Very truly yours, Peter A. Mazzaferro Acting Manager, Engineering Services PAM/MHS

Enclosure:

Nine Mile Point Unit 1 Core Operating Limits Report, COLR1-19, Revision 0 cc:

NRC Regional Administrator, Region I NRC Project Manager NRC Senior Resident Inspector Akou(

ENCLOSURE Nine Mile Point Unit 1 Core Operating Limits Report COLR1-19, Revision 0 Nine Mile Point Nuclear Station, LLC April 21, 2009

NINE MILE POINT UNIT 1 CORE OPERATING LIMITS REPORT Document No.:

COLRI-19 Revision 0 Name Title Date Prepared by:

Reviewed by:

Independently Reviewed by:

C. L me W. Carter R~.

lose R. Close Fuel Engineer Fuel Engineer Fuel Engineer Supervisor, Nuclear Fuels Services HL 0

/,44;1 2/2?z A

Approved by:

Approved by:

Approved by:

John Darweesh Supervisor, Reactor Entyineering 1,/I/o/

Phil Wengloski

  • -*)'

General 1..* c Supervisor, Nuclear Fuels Services This Controlled Document provides cycle specific core operating limits for use in conjunction with the Nine Mile Point Unit 1 Technical Specifications. Document pages may only be changed through a reissue of the entire document.

COLRI-19 NINE MILE POINT UNIT 1 CORE OPERATING LIMITS REPORT Revision 0 Table of Contents, 1.0 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR) 1.1 Limits for Technical Specification 3.1.7.a 1.2 Limits for Technical Specification 3.1.7.e 2.0 MINIMUM CRITICAL POWER RATIO (MCPR) 2.1 Limits for Technical Specification 3.1.7.c 2.2 Limits for Technical Specification 3.1.7.e 3.0 LINEAR HEAT GENERATION RATE (LHGR) 3.1 Limits for Technical Specifications 3.1.7.b 4.0 POWER/FLOW RELATIONSHIP DURING OPERATION 4.1 Limits for Technical Specification Table 3.1.7.d and e

5.0 REFERENCES

FOR TECHNICAL SPECIFICATION BASES 6.0 SOURCE DOCUMENTS Pag e 1.

1 1

2 2

2 3

3 4

4 5

6 Page i

COLR1-19 NINE MILE POINT UNIT 1.

Revision 0 CORE OPERATING LIMITS REPORT TERMS AND DEFINITIONS Average Planar Linear Heat Generation Rate (APLHGR)

'The Average Planar Linear Heat Generation Rate (APLHGR) shall be applicable to a specific planar height and is equal to the sum of the heat generation rate per unit length of fuel rod for all fuel rods in the specified bundle at the specified height, divided by the number of fuel rods in the fuel bundle at that height BOC Beginning of Cycle Core Maximum Fraction of Limiting Power Density (CMFLPD)

The highest value of the fraction of limiting power density which exists in the core Critical Power Ratio (CPR)

The ratio of critical power to the bundle power at the reactor condition of interest Eoc End of Cycle EOR End of Rated Conditions (i.e. cycle exposure at 100% power, 100% flow, all rods-out, all feedwater heaters in service and equilibrium xenon)

Fraction of Limiting Power Density (FLPD)

The linear heat generation rate (LHGR) existing at a given location divided by the specified LHGR limit for that bundle type FRTP Fraction of Rated Thermal Power where Rated Thermal Power equals 1850 MW K~f)

MCPR flow dependent multiplier Linear Heat Generation Rate (LHGR)

The heat generation per unit length of fuel rod. It is the integral of the heat flux over the heat transfer area associated with the fuel length MAPLHGR Maximum Average Planar Linear Heat Generation Rate Minimum Critical Power Ratio (MCPR)

The minimum in-core critical power ratio RSLD Reload Specific Lattice Data Document MDFWP

COLR1-19 NINE MILE POINT UNIT 1 Revision 0 CORE OPERATING LIMITS REPORT 1.0 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR) 1.1 Limits for Technical Specification 3.1.7.a, During power operations, the APLHGR(s) for each fuel type as a function of AVERAGE PLANAR EXPOSURE shall not exceed the limiting values shown in Table la, lb, Ic and ld 1.2 Limits for Technical Specification 3.1.7.e During partial loop operation with four recirculation loops in operation, the APLHGR as a function of average planar exposure shall not exceeed 98 percent of the limiting values shown in Table la, 1b, lc and Id.

During partial loop operation with three recirculation loops in operation, the APLHGR as a function of average planar exposure shall not exceeed 98 percent of the limiting values shown in Table la, Ib, Ic and Id.

Page 1 of 18

COLRI-19 NINE MILE POINT UNIT 1 Revision 0 CORE OPERATING LIMITS REPORT 2.0 MINIMUM CRITICAL POWER RATIO (MCPR) 2.1 Limits for Technical Specification 3.1.7.c During power operation, the operating MCPR at rated power and flow shall be greater than or equal to the Operating Limit MCPR0l) from the appropriate(2) Figure (2a thru 2d) times the K(f) shown in Figure 2e with tau (or"Y") defined as follows:

'U= ('ave - 'B) / (TA - 'B) where:

xA = 0.868 seconds, control rod average scram insertion time limit to notch 39 n

TB =.672 + 1.65 *[ N1 /Z, Ni ]1f2*.016 i=1 n

n Zae=(EN i T-i) /(EN i) i=l i=1 n = number of surveillance tests performed in cycle Ni = number of active control rods measured in the it surveillance test ti= average scram time to notch 39 of all rods measured in the i surveillance test N, = total number of active rods measured Additional limits for operation between 45% and 90% RTP (3) (4) are required for operations without a backup pressure regulator. These limits are shown in Figure 2f.

2.2 Limits for Technical Specification 3.1.7.e During 3 loop operation, the Operating Limit MCPR shall be increased by 0.02. No adjustment is needed during 4 loop operation.

NOTES:

1 Based on a 1.07 MCPR Safety Limit (SLCPR) 2 For the current exposure and feedwaterpump configuration. "Pump Combinations" are also described in operating procedure N 1-OP-16, attachment 13 3 Below 45% and above 90% RTP no additional limits are required for operation without a backup regulator 4 These limits are valid for 3, 4, and 5 loop operation. (Note that for the MCPR Limit for 70%0P<90%, ie.

MCPR Limit=(Rated OLMCPR)/FRTP, the Rated OLMCPR is as determined by 2.1 and 2.2 above.)

5 EOR on figures 2a through 2d is the End of Rated exposure as defined in the Cycle Management Report.

Page 2 of 18

COLRI-19 NINE MILE POINT UNIT 1 CORE OPERATING LIMITS REPORT 3.0 LINEAR HEAT GENERATION RATE (LHGR) 3.1 Limits for Technical Specification 3.1.7.b During power operation, the Linear Heat Generation Rate (LHGR) of any rod in any fuel assembly at any axial location shall not exceed the limiting values shown in RSLD-20, Revision 0, "Nine Mile Point Unit 1 Reload 20, Reload Specific Data".

This document contains the LHGR limits for both U02 rods (which contain no gadolinium) and the most limiting gadolinium-bearing rods. Other gadolinium-bearing rods have LHGR limits which lie between thesetwo curves. Compliance with these limits will be monitored by the plant's process computer.

Additional limits for operation between 45% and 90% RTP(1) are required for operations without a backup pressure regulator. These limits are shown in figure 3.

NOTE:

1 Below 45 % and above 90% RTP no additional limits are required for operation without a backup pressure regulator.

Revision 0 Page 3 of 18

COLR1-19 NINE MILE POINT UNIT 1 CORE OPERATING LIMITS REPORT 4.0 POWER/FLOW RELATIONSHIP DURING OPERATION 4.1 Limits for Technical Specification 3.1.7.d and e The power/flow relationship shall not exceed the limiting values shown in Figure 4.

Revision 0 Page 4 of 18

COLR1-19 NINE MILE POINT UNIT I CORE OPERATING LIMITS REPORT Revision 0 5.0 REFERENCE FOR TECHNICAL SPECIFICATIONS Technical Specification 6.6.5b:

NEDE 24011-P-A, "General Electric Standard Application for Reactor Fuel,"

U.S. Supplement, Revision 16, October 2007 Page 5 of 18

COLR1-19 NINE MILE POINT UNIT 1 CORE OPERATING LIMITS REPORT Revision 0 6.0 SOURCE DOCUMENTS The Core Operating Limits contained in this report were obtained from the following documents:

CORE OPERATING LIMITS REFERENCES APLHGR Limits (Section 1.0)

Table 1 and corresponding 3 and 4 loop multipliers Lattice Descriptions MCPR Limits (Section 2)

Pressure. Regulator Out-of-Service Restrictions EOR Definition LHGR Limits (Section 3)

Pressure Regulator Out-of-Service Restrictions Power/Flow Relationshio (Section 4) 0000-0084-3226-SRLR, Revision 0, December.

2008, Supplemental Reload Licensing Report for Nine Mile Point 1, Reload 20, Cycle 19 0000-0084-3226-FBIR, Revison 0, December 2008 Fuel Bundle Information Report for Nine Mile Point 1, Reload 20, Cycle 19 0000-0084-3226-SRLR, Revision 0, December 2008, Supplemental Reload Licensing Report for Nine Mile Point 1, Reload 20, Cycle 19 GE-NE-J 11-03433-16-01 -R1, "Pressure Regulator Out of Service Calculations for Nine Mile Point Unit 1", January 2005 NMP1CMR, Revision 18, Nine Mile Point Unit 1, Cycle 19, Cycle Management Report, April 2009 0000-0084-3226-FBIR, Revison 0, December 2008 Fuel Bundle Information Report for Nine Mile Point 1, Reload 20, Cycle 19 GE-NE-J1 1-03433-16-01 -RI, "Pressure Regulator Out of Service Calculations for Nine Mile Point Unit 1", January 2005 NMP1 Technical Specification Amndment 92, Figure 3.1.7.a Page 6 of 18

COLR1-19 NINE MILE POINT UNIT I CORE OPERATING LIMITS REPORT Table la Revision 0 MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE (1)(2)

Average Planar Exposure MAPLHGR Limits'(kw/ft)

GWd/ST Bundle Bundle Bundle 2585 2586 2831 0.00 9.93 9.93 9.81 0.20 9.93 9.93 9.81 1.00 9.89 9.90 9.78 5.00 9.78 9.70 9.64 10.00 9.61 9.67 9.49 15.00 9.53 9.53

.9.36 17.50 9.53 20.00 9.08 9.04 8.87 25.00 8.83 8.60 8.55 30.00 8.63 35.00 8.60 8.36 8.47 45.00 8.62 8.28 8.48 50.00 8.65 55.00 8.66 8.27 8.54 65.00 6.38 6.38 8.63 NOTE:

(1) A "--" indicates that there is no entry for this box and the limit can be determined by linearly interpolating between the previous and next point in each column.

MAPLHGRs are interpolated between exposure points for which explicit values are given.

(2) These MAPLHGRs are not lattice dependent, therefore the values shown also correspond to the limiting value for the most limiting lattice for use when hand calculations are required.

Fuel Type ID GEl 1 -P9DUB376-12GZ-1 OOT-1 45-T6-2585 GEl 1-P9DUB376-12GZ-10OT-145-T6-2586 GEl 1 -P9DUB382-13GZ-1 0OT-1 45-T6-2831 2585 2586 2831 Page 7 of 18

COLR1-19 NINE MILE POINT UNIT 1 CORE OPERATING LIMITS REPORT Revision 0 Table lb MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GE11-P9DUB381-13GZ-10OT-145-T6-2945 (GEl1)

Average Planar MAPLHGR Limits&" (kw/ft)

Exposure Lattice Lattice Lattice Lattice Lattice Lattice Most GWd/ST 7433 7434 7435 7436 7437 7438 Limiting 0.00 9.91 9.91 9.87 9.87 9.87 9.87 9.87 0.20 9.91 9.91 9.87 9.87 9.87 9.87 9.87 1,00

.9.87 9.87 9.86 9.86 9.86 9.86 9.86 5.00 9.72 9.72 9.76 9.76 9.76 9.76

.9.72 10.00 9.67 9.67 9.63 9.63 9.63 9.63 9.63 15.00 9.51 9.51 9.52 9.52 9.52 9.52 9.51 20.00 9.47 9.47 9.48 9.48 9.48 9.48 9.47 25.00 8.77 8.77 8.74 8.74 8.74 8.74 8.74 35.00 8.45 8.45 8.54 8.54 8.54 8.54 8.45 45.00 8.53 8.53 8.53 8.53 8.53 8.53 8.53 55.00 8.57 8.57 8.57 8.57 8.57 8.57 8.57,.

65.00 8.64 8.64 8.64 8.64 8.64 8.64 8.64 (1) These MAPLHGR are lattice dependent. The values shown in the Most Limiting Column correspond to the limiting value for the most limiting lattice for use when hand calculations are required. Lattice descriptions are contained in the RSLD.

Page 8 of 18

COLR1-19 NINE MILE POINT UNIT 1 CORE OPERATING LIMITS REPORT Table 1c MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GEl1-P9DUB381-14GZ-10OT-145-T6-2946 (GEl1)

Revision 0 Average Planar MAPLHGR Limits"*

(kw/ft)

Exposure Lattice Lattice Lattice Lattice Lattice Lattice Most GWd/ST 7433 7439 7440 7441 7442 7443 Limiting 0.00 10.56 10.56 10.51 10.51 10.51 10.51 10.51 0.20 10.56 10.56 10.51 10.51 10.51 10.51 10.51 1.00 10.52' 10.52 10.51 10.51 10.51 10.51 10.51 5.00 10.22 10.22 10.16 10.16 10.16 10.16 10.16 10.00 9.72 9.72 9.63 9.63 9.63 9.63 9.63 15.00 9.51 9.51 9.48 9.48 9.48 9.48 9.48 20.00 9.47 9.47 9.48 9.48 9.48 9.48 9.47 25.00 8.91 8.91 8.90 8.90 8.90 8.90 8.90 35.00 8.34 8.34 8.34 8.34 8.34 8.34 8.34 45.00 8.27 8.27 8.24 8.24 8.24 8.24 8.24 55.00 8.25 8.25 8.24 8;24 8.24 8.24 8.24 65.00 8.22 8.22 8.21 8.21 8.21 8.21 8.21 (1) These MAPLHGR are lattice dependent. The values shown in the Most Limiting Column correspond to the limiting value for the most limiting lattice for use when hand calculations are required. Lattice descriptions are contained in the RSLD.

Page 9 of 18

COLR1-19 NINE MILE POINT UNIT 1 CORE OPERATING LIMITS REPORT Table ld MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GEl 1 -P9DUB380-13GZ-1 OOT-1 45-T6-2948 (GEl 1)

Revision 0 Average Planar MAPLHGR Limits&1' (kw/ft)

Exposure Lattice Lattice Lattice Lattice Lattice Lattice Most GWd/ST 7433 7449 7450 7451 7447 7448 Limiting 0.00 10.02 10.02 10.00 10.00 10.00 10.00 10.00 0.20 10.02 10.02 1.0.00 10.00 10.00 10.00 10.00 1.00 9.99 9.99 9.97 9.97 9.97 9.97 9.97 5.00 9.86 9.86 9.80 9.80 9.80 9.80 9.80

.10.00 9.68 9.68 9.61 9.61 9.61 9.61 9.61 15.00 9.52 9.52 9.53 9.53 9.53 9.53 9.52 20.00 9.57 9.57 9.60 9.60 9.60 9.60 9.57 25.00 8.70 8.70 8.72 8.72 8.72 8.72 8.70 35.00 8.35 8.35 8.35 8.35 8.35 8.35 8.35 45.00 8.23 8.23 8.27 8.27

.8.27 8.27 8.23 55.00 8.22 8.22 8.23 8.23 8.23 8.23 8.22 65.00 8.16 8.16 8.18 8.18 8.18 8.18 8.16 (1) These MAPLHGR are lattice dependent. The values shown in the Most Limiting Column correspond to the limiting value for the most limiting lattice for use when hand calculations are required. Lattice descriptions are contained in the RSLD.

Page 10 of 18

'f.

COLRI-19 NINE MILE POINT UNIT I CORE OPERATING LIMITS REPORT Revision 0 Figure 2a MCPR Operating Limits for Feedwater Pump Combination I maximum flows Beginning Of Cycle to EOR*-1426 MWd/ST (Bounds TDFWP+MDFWP, TDFWP only, MDFWP only, two MDFWPs) 1.54 1.52 1.5 0,

  • 1.48 0

U01.46 EE 1.44 1.42 (1, 1.52) 1.4 0

0.2 0.4, 0.6 0.8 Tau 1

  • EOR is the end of rated exposure as defined in the Cycle Management Report Page 11 of 18

COLR1-19 NINE MILE POINT UNIT 1 CORE OPERATING LIMITS REPORT Revision 0 Figure 2b MCPR Operating Limits for Feedwater Pump Combination 1 maximum flows EOR*-1426 MWd/ST to End Of Cycle (Bounds TDFWP+MDFWP, TDFWP only, MDFWP only, two MDFWPs) 1.56 1.54 1.52 m 1.5 g.

1.48 E

E 1.46 (1, 1.54) 1.44 1.42 0

0.2 0.4 0.6 0.8 Tau

  • EOR is the end of rated exposure as defined in the Cycle Management Report Page 12 of 18

COLR1-19 NINE MILE POINT UNIT 1 CORE OPERATING LIMITS REPORT Revision 0 Figure 2c MCPR Operating Limits for Feedwater Pump Combination 2maximum flows Beginning of Cycle to EOR*-1426 MWd/ST (Bounds TDFWP+ two MDFWPs) 1.58 1.56 1.54 C.

(L

  • 1.52 0

()

E1.5 E
3 (1, 1.56) 1.48 1.46 1.44 0

0.2 0.4 0.6 0.8 Tau 1

  • EOR is the end of rated exposure as defined in the Cycle Management Report Page 13 of 18

t COLR1-19 NINE MILE POINT UNIT 1 CORE OPERATING LIMITS REPORT Revision 0, Cycle 19 Figure 2d MCPR Operating Limits for Feedwater Pump Combination 2 maximum flows EOR*-1426 MWd/ST to End Of Cycle (Bounds TDFWP+ two MDFWPs) 1.6 1.58 1.56 a)

  • 1.54 1.52 E

E 1.5 1.5 (1, 1.59) 1.46 0

0.2 0.4 0.6 0.8 Tau

  • EOR is the end of rated exposure as defined in the Cycle Management Report 14 of 18

COLR1-19 NINE MILE POINT UNIT I CORE OPERATING LIMITS REPORT Figure 2e NMP-1 -K(f) Curve for MCPR Revision 0 1.5 1.4 1.3 a.

0

  • _K(f) =

i hen 45% > Flow.

Otl erwise:

102.5% K(f) = MAX(

.0, 1.33075 - 0.441

  • F oWl 100% )

-107.0%

K(f) = MAX(

.0, 1.35280 -0.441

  • F ow / 100%)

112.0% K(f)=MAX(.0, 1.37926- 0.441 *Flow/ 100%)

1170no/ K(-

v-=tA(

.0 1.40352- 0.41 Fqw 100%

-Automatic K(f) =MA(1.0, 1.441 -0.441 *Fowl100% )

Automatic Flow Control 117% Scoop Tube Setting 112% Scoop Tube Setting.

107% Scoop.Tube Setting 102.5% Scoot Tube Setting 1.2 1.1 0.9 0

  • 20 40 60 Core Flow (% of Rated) 80 100 120 Page 15 of 18

COLRI-19 NINE MILE POINT UNIT 1 CORE OPERATING LIMITS REPORT Revision 0 Figure 2f: MCPR Limits for Operation Between 45% and 90% RTP Without a Backup Presssure Regulator 2.3 2.2 2.1 2

a-1.9 1.8 1.7 45 50 55 60 65 Core Thermal Power (P) in units of % Rated Thermal Power (%RTP) 70 Page 16 of 18

COLRI-19 NINE MILE POINT UNIT 1 Revision 0 CORE OPERATING LIMITS REPORT Figure 3: LHGR Limits for Operation Between 45% and 90% RTP Without a Backup Presssure Regulator 1.2 0.8 Core Flow

  • 75%

E

a.

0.6 u-e Operating CMFLPD shall be < CMFLPD limit line 0.4 CMFLPD Limit =

For 45%

  • P g 70% AND Core Flow < 75% Flow 0.2 CMFLPD Limit= [0.8-0.01(70%-P)]

ELSE For 45% < P<90%:

CMFLPD Limit = FRTP 400 45 50 55 60 65 70 75 80

  • 85 90 Core Thermal Power (P) In units of % Rated Thermal Power (%RTP)

Page 17 of 18

COLR1-19 NINE MILE POINT UNIT I CORE OPERATING LIMITS REPORT Figure 4 Limiting Power/Flow Line Revision 0 I

120.00 100.00 0.

I-8 80.00 60.00 40.00 (85.0,100.6)

(100.0,100.0)

Limiting Power / Flow Line Pow er= 0.55 Flow + 53.25 20.00 0.00 0

20 40 60 Core Flow (% of Rated) 80 100 120 Page 18 of 18