| title = Response to NRC Inspection Report 05000382-06-003 Notice of Violation
| title = Response to NRC Inspection Report 05000382-06-003 Notice of Violation
| author name = Dunham Z K
| author name = Dunham Z
| author affiliation = NRC/RGN-IV/DRP/RPB-E
| author affiliation = NRC/RGN-IV/DRP/RPB-E
| addressee name = Venable J E
| addressee name = Venable J
| addressee affiliation = Entergy Operations, Inc
| addressee affiliation = Entergy Operations, Inc
| docket = 05000382
| docket = 05000382

Revision as of 10:30, 13 July 2019

Response to NRC Inspection Report 05000382-06-003 Notice of Violation
ML063040721
Person / Time
Site: Waterford Entergy icon.png
Issue date: 10/30/2006
From: Dunham Z
NRC/RGN-IV/DRP/RPB-E
To: Venable J
Entergy Operations
References
IR-06-003
Download: ML063040721 (5)


See also: IR 05000382/2006003

Text

October 30, 2006EA-06-192Joseph E. VenableVice President Operations

Waterford 3

Entergy Operations, Inc.

17265 River Road

Killona, LA 70066-0751SUBJECT: WATERFORD STEAM ELECTRIC STATION, UNIT 3 - RESPONSE TO NRC INSPECTION REPORT 05000382/2006003 NOTICE OF VIOLATION Dear Mr. Venable:Thank you for your letter of September 18, 2006, in response to our letter and Notice ofViolation dated August 18, 2006, involving the failure to translate into specifications, procedures

and instructions the design criteria for the emergency diesel air start system. We have

reviewed your reply and find it responsive to the concerns raised in our Notice of Violation. We

will review the implementation of your corrective actions during a future inspection to determine

that full compliance has been achieved and will be maintained.Sincerely,

/RA/

Zachary K. Dunham, ChiefBranch E

Division of Reactor ProjectsDocket: 50-382License: NPF-38

Entergy Operations, Inc.-2-

cc:Senior Vice President and

Chief Operating Officer

Entergy Operations, Inc.

P.O. Box 31995

Jackson, MS 39286-1995Vice President, Operations SupportEntergy Operations, Inc.

P.O. Box 31995

Jackson, MS 39286-1995Wise, Carter, Child & CarawayP.O. Box 651

Jackson, MS 39205General Manager, Plant OperationsWaterford 3 SES

Entergy Operations, Inc.

17265 River Road

Killona, LA 70066-0751Manager - Licensing ManagerWaterford 3 SES

Entergy Operations, Inc.

17265 River Road

Killona, LA 70066-0751ChairmanLouisiana Public Service Commission

P.O. Box 91154

Baton Rouge, LA 70821-9154Director, Nuclear Safety & Regulatory Affairs

Waterford 3 SES

Entergy Operations, Inc.

17265 River Road

Killona, LA 70066-0751Richard Penrod, Senior Environmental Scientist

Office of Environmental Services

Northwestern State University

Russsell Hall, Room 201

Natchitoches, LA 71497

Entergy Operations, Inc.-3-Parish President

St. Charles Parish

P.O. Box 302

Hahnville, LA 70057Winston & Strawn LLP1700 K Street, N.W.

Washington, DC 20006-3817

Entergy Operations, Inc.-4-Electronic distribution by RIV:Regional Administrator (BSM1)DRP Director (ATH)DRS Director (DDC)DRS Deputy Director (RJC1)Senior Resident Inspector (GFL1)Branch Chief, DRP/E (ZKD)Senior Project Engineer, DRP/E (DLL1)Team Leader, DRP/TSS (RVA)RITS Coordinator (KEG)SUNSI Review Completed: _ZKD__ADAMS: Yes G No Initials: __ZKD_ Publicly Available

G Non-Publicly Available

G Sensitive Non-SensitiveR:_REACTORS\WT\2006\WT 2006-03RP Response.wpd RIV:C:DRP/E

ZKDunham/RA/10/30/06OFFICIAL RECORD COPY T=Telephone E=E-mail F=Fax