Line 2: Line 2:
| number = ML103160140
| number = ML103160140
| issue date = 11/12/2010
| issue date = 11/12/2010
| title = St. Lucie Units 1 and 2 - Request for Additional Information Regarding an Exemption to 10 CFR 26.205(c) and 26.205(d)
| title = Request for Additional Information Regarding an Exemption to 10 CFR 26.205(c) and 26.205(d)
| author name = Orf T J
| author name = Orf T J
| author affiliation = NRC/NRR/DORL/LPLII-2
| author affiliation = NRC/NRR/DORL/LPLII-2

Revision as of 02:26, 13 April 2019

Request for Additional Information Regarding an Exemption to 10 CFR 26.205(c) and 26.205(d)
ML103160140
Person / Time
Site: Saint Lucie  NextEra Energy icon.png
Issue date: 11/12/2010
From: Orf T J
Plant Licensing Branch II
To: Katzman E, Frehafer K
Florida Power & Light Co
Orf, T J, NRR/DORL/301-415-2788
References
Download: ML103160140 (2)


Text

From: Orf, Tracy Sent: Friday, November 12, 2010 10:08 AM To: Katzman, Eric; Frehafer, Ken

Subject:

Part 26 Exemption questions Eric/Ken, The staff has a couple clarifying questions that they would like answered in regards to FPL's request for an exemption from 10 CFR 26.205(c) and (d) work hour control requirements during certain situations (e.g., tropical storm force winds):

The licensee's letter dated September 2, 2010, includes a response to an NRC request for additional information. The responses to NRC questions 1 and 2 include the phrase "and they have had sufficient time off to reset their work hour clock." The response to NRC question 4 has a similar reference to a reset of a work hour clock. These phrases are in regard to the criteria that Senior Management/Emergency Coordinator will use to reestablish work hour controls.

a. Please clarify what is meant by the phrase "reset their work hour clock"
b. Please provide the criteria used to verify that a reset is established.

Please provide a response within 30 days so that the NRC staff may complete its review in a timely manner. If you have any questions regarding this matter, you may contact me by email or at the number below.

Best regards, Tracy J. Orf, Project Manager St. Lucie Plant Licensing Branch II-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Phone: (301) 415-2788 E-mail Properties Mail Envelope Properties ()

Subject:

Part 26 Exemption questions

Sent Date: 11/12/2010 9:58:54 AM Received Date: 11/12/2010 10:07:00 AM From: Orf, Tracy

Created By: Tracy.Orf@nrc.gov

Recipients: Eric.Katzman@fpl.com (Katzman, Eric)

Tracking Status: None Ken.Frehafer@fpl.com (Frehafer, Ken)

Tracking Status: None Post Office:

Files Size Date & Time

MESSAGE 13739 11/12/2010

Options Expiration Date:

Priority: olImportanceNormal ReplyRequested: False Return Notification: False

Sensitivity: olNormal Recipients received: