{{#Wiki_filter:ES-301 Administrative Topics Outline Form ES-301-1 Facility:
{{#Wiki_filter:ES-301                           Administrative Topics Outline                           Form ES-301-1 Facility: Dresden                                                     Date of Examination: 04/06/2014 Examination Level: RO~ SRO         0                                 Operating Test Number:14-1 (2015-301)
Dresden Date of Examination:
Administrative Topic         Type Describe activity to be performed (See Note)               Code*
04/06/2014 Examination Level: SRO 0 Operating Test Number:14-1 (2015-301)
                                                  \
Administrative Topic Type Describe activity to be performed (See Note) Code* \ Conduct of Operations S,D Review Acceptance Criteria Met For Acoustic Monitor Generic.2.1.
Review Acceptance Criteria Met For Acoustic Monitor Conduct of Operations              S,D Generic.2.1. 7   4.4/--
7 4.4/--Conduct of Operations S,D U1 & 2/3 CST Inventory Calculations Generic.2.1.18 3.6/--Equipment Control S,P,D Identify Requirements For A Valve Stroke Timing Error Generic.2.2.14 3.9/--Radiation Control N,S Determine Brief And Protective Clothing Requirements Generic.2,3.
U1 & 2/3 CST Inventory Calculations Conduct of Operations              S,D Generic.2.1.18     3.6/--
7 3.5/--Emergency Procedures/Plan NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when 5 are required.  
Identify Requirements For A Valve Stroke Timing Error Equipment Control                S,P,D Generic.2.2.14     3.9/--
*Type Codes & Criteria: (C)ontrol room, (S)imulator, or Class(R)oom (D)irect from 3 for ROs; 4 for SROs & RO retakes) (N)ew or (M)odified from
Determine Brief And Protective Clothing Requirements Radiation Control                  N,S Generic.2,3. 7   3.5/--
: 1) (P)revious 2 exams 1; randomly selected)
Emergency Procedures/Plan NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when 5 are required.
ES 301, Page 22 of 27 ES-301 Administrative Topics Outline Form ES-301-1 Facility:
*Type Codes & Criteria:             (C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank(~  3 for ROs;   ~ 4 for SROs & RO retakes)
Dresden Date of Examination:
(N)ew or (M)odified from bank(~ 1)
04/06/2014 Examination Level: RO 0 SRO IZI Operating Test Number:14-1 (2015-301)
(P)revious 2 exams (~ 1; randomly selected)
Administrative Topic Type Describe activity to be performed (See Note) Code* Conduct of Operations S,D Reportability determination
ES 301, Page 22 of 27
-Contaminated Worker Generic.2.1.1  
 
/4.2 Determination of On-Line Risk Conduct of Operations S,N Generic.2.1.19  
ES-301                           Administrative Topics Outline                           Form ES-301-1 Facility: Dresden                                                     Date of Examination: 04/06/2014 Examination Level: RO     0   SRO   IZI                               Operating Test Number:14-1 (2015-301)
/3.8 Equipment Control S,D Verify Reversal Of EOG Cooling Water Flow Surveillance Generic.2.2.12  
Administrative Topic           Type Describe activity to be performed (See Note)               Code*
/4.1 Select Personnel For Radiation Work Radiation Control S,P,D Generic.2.3.13  
Reportability determination - Contaminated Worker Conduct of Operations               S,D Generic.2.1.1   /4.2 Determination of On-Line Risk Conduct of Operations               S,N Generic.2.1.19   /3.8 Verify Reversal Of EOG Cooling Water Flow Surveillance Equipment Control                    S,D Generic.2.2.12   /4.1 Select Personnel For Radiation Work Radiation Control                 S,P,D Generic.2.3.13   /3.8 Determination Of EP Classification And Fill Out NARS Emergency Procedures/Plan           S,N       Form Generic.2.4.44   /4.4 NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when 5 are required.
/3.8 Determination Of EP Classification And Fill Out NARS Emergency Procedures/Plan S,N Form Generic.2.4.44  
* Type Codes & Criteria:             (C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank(~ 3 for ROs; ~ 4 for SROs & RO retakes)
/4.4 NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when 5 are required.
(N)ew or (M)odified from bank (2: 1)
* Type Codes & Criteria: (C)ontrol room, (S)imulator, or Class(R)oom (D)irect from 3 for ROs; 4 for SROs & RO retakes) (N)ew or (M)odified from bank (2: 1) (P)revious 2 exams 1; randomly selected)
(P)revious 2 exams (~ 1; randomly selected)
ES 301, Page 22 of 27 ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility:
ES 301, Page 22 of 27
Dresden Date of Examination:
 
04/06/2015 Exam Level: RO SRO-I D SRO-U D Operating Test Number: 14-1 (2015-301}
ES-301                           Control Room/In-Plant Systems Outline                             Form ES-301-2 Facility: Dresden                                                       Date of Examination: 04/06/2015 Exam Level: RO ~ SRO-I         D   SRO-U   D                         Operating Test Number: 14-1 (2015-301}
Control Room Systems@ (8 for RO); (7 for SRO-I); (2 or 3 for SRO-U, including 1 ESF) System I JPM Title Type Code* Safety Function a. 202001 A4.01 3.7/3.7 ASD -Change Reactor Power With Recirc Flow N, A, S 1 b. 204000 A4.06 3.0/2.9 RWCU -Secure Rapidly During A Transient D,L,S 2 c. 241000 A4.06 3.9/3.9 DEHC-Establish RPV Cooldown w/ Bypass D, L, S 3 Valves d. 203000 A1 .04 3.6/3.6 LPCI -Mitigate high Suction Pressure While D,A,S 4 Lining Up CST Suction For Injection
Control Room Systems@ (8 for RO); (7 for SRO-I); (2 or 3 for SRO-U, including 1 ESF)
: e. 223001 A4.07 4.2/4.1 Containment  
Safety System I JPM Title                                       Type Code*
-Vent Torus w/ Valve Failure A,D,S 5 f. 262001 A4.04 3.6/3. 7 Aux Power -X-Fer to TR-22 from TR-21 A,D,S 6 g. 215002 A2.05 3.2/3.3 Clear RBM D,P,S 7 h. 290003 A4.01 3.2/3.2 CREV -Secure A AHU and Start B RCU D,S 9 In-Plant Systems@ (3 for RO); (3 for SRO-I}; (3 or 2 for SRO-U) i. 264000 K1 .05 3.2/3.3 EDG -Manually fill 2/3 EDG Day Tank D,R 6 j. 207000 A 1.01 3. 7 /3.8 IC M/U Pump Local Operation w/ Failure A,P 4 k. 300000 K4.02 3.0/3.0 Crosstie U1 and U2 Instrument Air N,E 8 @ All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room. *Type Codes Criteria for RO I SRO-I I SRO-U (A)lternate path 4-6 I 4-6 I 2-3 (C)ontrol room (D)irect from bank I 4 (E)mergency or abnormal in-plant 1 I I 1 (EN)gineered safety feature -I -I 1 (control room system (L)ow-Power I Shutdown 1 I I 1 (N)ew or (M)odified from bank including 1 (A) I 1 (P)revious 2 exams 3/ I 2 (randomly selected) (R)CA 1 I I 1 (S)imulator ES-301, Page 23 of 27 ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility:
Function
Dresden Date of Examination:
: a. 202001 A4.01 3.7/3.7 ASD - Change Reactor Power With Recirc Flow                       N, A, S           1
04/06/2015 Exam Level: RO D SRO-I SRO-U D Operating Test Number: 14-1 (2015-301)
: b. 204000 A4.06 3.0/2.9 RWCU - Secure Rapidly During A Transient                           D,L,S           2
Control Room Systems@ (8 for RO); (7 for SRO-I}; (2 or 3 for SRO-U, including 1 ESF) System I JPM Title Type Code* Safety Function a. 202001 A4.01 3.7/3.7 ASD -Change Reactor Power With Recirc Flow N,A,S 1 b. 204000 A4.06 3.0/2.9 RWCU -Secure Rapidly During A Transient D, L, S 2 C. d. 203000 A1 .04 3.6/3.6 LPCI -Mitigate high Suction Pressure While D,A,S 4 Lining Up CST Suction For Injection
: c. 241000 A4.06 3.9/3.9 DEHC- Establish RPV Cooldown w/ Bypass                             D, L, S         3 Valves
: e. 223001 A4.07 4.2/4.1 Containment-Vent Torus w/ Valve Failure A,D,S 5 f. 262001 A4.04 3.6/3.7 Aux Power-X-Fer to TR-22 from TR-21 A,D,S 6 g. 215002 A2.05 3.2/3.3 Clear RBM D,P,S 7 h. 290003 A4.01 3.2/3.2 CREV -Secure A AHU and Start B RCU D,S 9 In-Plant Systems@ (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U) i. 204000 K1 .05 3.2/3.3 EDG -Manually fill 2/3 EDG Day Tank D,R 6 j. 207000 A 1.01 3.7/3 .. 8 IC M/U Pump Local Operation w/ Failure A,P 4 k. 300000 K4.02 3.0/3.0 Crosstie U1 and U2 Instrument Air N, E 8 @ All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
: d. 203000 A1 .04 3.6/3.6 LPCI - Mitigate high Suction Pressure While                       D,A,S           4 Lining Up CST Suction For Injection
* Type *Codes Criteria for RO I SRO-I I SRO-U (A)lternate path 4-6 I 4-6 I 2-3 (C)ontrol room (D)irect from bank I (E)mergency or abnormal in-plant 1 I > 1 I 1 (EN)gineered safety feature -I -I 1 (control room system (L)ow-Power I Shutdown 1 I I 1 (N)ew or (M)odified from bank including 1(A) I 1 (P)revious 2 exams 3/ I 2 (randomly selected) (R)CA 1 I I 1 (S)imulator ES-301, Page 23 of 27 ES-301 Administrative Topics Outline Form ES-301-1 Facility:
: e. 223001 A4.07 4.2/4.1 Containment - Vent Torus w/ Valve Failure                         A,D,S             5
Dresden Date of Examination:
: f. 262001 A4.04 3.6/3. 7 Aux Power - X-Fer to TR-22 from TR-21                             A,D,S             6
04/06/2014 Examination Level: SRO 0 Operating Test Number:14-1 (2015-301)
: g. 215002 A2.05 3.2/3.3 Clear RBM                                                           D,P,S           7
Administrative Topic Type Describe activity to be performed (See Note) Code* \ Conduct of Operations S,D Review Acceptance Criteria Met For Acoustic Monitor Generic.2.1.
: h. 290003 A4.01 3.2/3.2 CREV - Secure A AHU and Start B RCU                                 D,S             9 In-Plant Systems@ (3 for RO); (3 for SRO-I}; (3 or 2 for SRO-U)
7 4.4/--Conduct of Operations S,D U1 & 2/3 CST Inventory Calculations Generic.2.1.18 3.6/--Equipment Control S,P,D Identify Requirements For A Valve Stroke Timing Error Generic.2.2.14 3.9/--Radiation Control N,S Determine Brief And Protective Clothing Requirements Generic.2,3.
: i. 264000 K1 .05 3.2/3.3 EDG - Manually fill 2/3 EDG Day Tank                               D,R             6
7 3.5/--Emergency Procedures/Plan NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when 5 are required.  
: j. 207000 A 1.01 3. 7/3.8 IC M/U Pump Local Operation w/ Failure                             A,P             4
*Type Codes & Criteria: (C)ontrol room, (S)imulator, or Class(R)oom (D)irect from 3 for ROs; 4 for SROs & RO retakes) (N)ew or (M)odified from
: k. 300000 K4.02 3.0/3.0 Crosstie U1 and U2 Instrument Air                                   N,E             8
: 1) (P)revious 2 exams 1; randomly selected)
  @       All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
ES 301, Page 22 of 27 ES-301 Administrative Topics Outline Form ES-301-1 Facility:
                  *Type Codes                                     Criteria for RO I SRO-I I SRO-U (A)lternate path                                                     4-6 I   4-6 I 2-3 (C)ontrol room (D)irect from bank                                                   ~9/    ~8    I ~4 (E)mergency or abnormal in-plant                                     ~ 1 I ~1    I ~ 1 (EN)gineered safety feature                                           - I     -   I ~ 1 (control room system (L)ow-Power I Shutdown                                               ~ 1 I   ~1    I ~ 1 (N)ew or (M)odified from bank including 1(A)                         ~21    ~2    I ~ 1 (P)revious 2 exams                                                   ~ 3/   ~3    I ~ 2 (randomly selected)
Dresden Date of Examination:
(R)CA                                                                 ~ 1 I ~1    I ~ 1 (S)imulator ES-301, Page 23 of 27
04/06/2014 Examination Level: RO 0 SRO IZI Operating Test Number:14-1 (2015-301)
 
Administrative Topic Type Describe activity to be performed (See Note) Code* Conduct of Operations S,D Reportability determination
ES-301                           Control Room/In-Plant Systems Outline                           Form ES-301-2 Facility: Dresden                                                       Date of Examination: 04/06/2015 Exam Level: RO       D   SRO-I ~ SRO-U       D                       Operating Test Number: 14-1 (2015-301)
-Contaminated Worker Generic.2.1.1  
Control Room Systems@ (8 for RO); (7 for SRO-I}; (2 or 3 for SRO-U, including 1 ESF)
/4.2 Determination of On-Line Risk Conduct of Operations S,N Generic.2.1.19  
Safety System I JPM Title                                     Type Code*
/3.8 Equipment Control S,D Verify Reversal Of EOG Cooling Water Flow Surveillance Generic.2.2.12  
Function
/4.1 Select Personnel For Radiation Work Radiation Control S,P,D Generic.2.3.13  
: a. 202001 A4.01 3.7/3.7 ASD - Change Reactor Power With Recirc Flow                         N,A,S             1
/3.8 Determination Of EP Classification And Fill Out NARS Emergency Procedures/Plan S,N Form Generic.2.4.44  
: b. 204000 A4.06 3.0/2.9 RWCU - Secure Rapidly During A Transient                           D, L, S         2 C.
/4.4 NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when 5 are required.
: d. 203000 A1 .04 3.6/3.6 LPCI - Mitigate high Suction Pressure While                       D,A,S           4 Lining Up CST Suction For Injection
* Type Codes & Criteria: (C)ontrol room, (S)imulator, or Class(R)oom (D)irect from 3 for ROs; 4 for SROs & RO retakes) (N)ew or (M)odified from bank (2: 1) (P)revious 2 exams 1; randomly selected)
: e. 223001 A4.07 4.2/4.1 Containment-Vent Torus w/ Valve Failure                           A,D,S             5
ES 301, Page 22 of 27 ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility:
: f. 262001 A4.04 3.6/3.7 Aux Power- X-Fer to TR-22 from TR-21                               A,D,S             6
Dresden Date of Examination:
: g. 215002 A2.05 3.2/3.3 Clear RBM                                                           D,P,S             7
04/06/2015 Exam Level: RO SRO-I D SRO-U D Operating Test Number: 14-1 (2015-301}
: h. 290003 A4.01 3.2/3.2 CREV - Secure A AHU and Start B RCU                                 D,S             9 In-Plant Systems@ (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)
Control Room Systems@ (8 for RO); (7 for SRO-I); (2 or 3 for SRO-U, including 1 ESF) System I JPM Title Type Code* Safety Function a. 202001 A4.01 3.7/3.7 ASD -Change Reactor Power With Recirc Flow N, A, S 1 b. 204000 A4.06 3.0/2.9 RWCU -Secure Rapidly During A Transient D,L,S 2 c. 241000 A4.06 3.9/3.9 DEHC-Establish RPV Cooldown w/ Bypass D, L, S 3 Valves d. 203000 A1 .04 3.6/3.6 LPCI -Mitigate high Suction Pressure While D,A,S 4 Lining Up CST Suction For Injection
: i. 204000 K1 .05 3.2/3.3 EDG - Manually fill 2/3 EDG Day Tank                               D,R             6
: e. 223001 A4.07 4.2/4.1 Containment  
: j. 207000 A 1.01 3.7/3 ..8 IC M/U Pump Local Operation w/ Failure                           A,P             4
-Vent Torus w/ Valve Failure A,D,S 5 f. 262001 A4.04 3.6/3. 7 Aux Power -X-Fer to TR-22 from TR-21 A,D,S 6 g. 215002 A2.05 3.2/3.3 Clear RBM D,P,S 7 h. 290003 A4.01 3.2/3.2 CREV -Secure A AHU and Start B RCU D,S 9 In-Plant Systems@ (3 for RO); (3 for SRO-I}; (3 or 2 for SRO-U) i. 264000 K1 .05 3.2/3.3 EDG -Manually fill 2/3 EDG Day Tank D,R 6 j. 207000 A 1.01 3. 7 /3.8 IC M/U Pump Local Operation w/ Failure A,P 4 k. 300000 K4.02 3.0/3.0 Crosstie U1 and U2 Instrument Air N,E 8 @ All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room. *Type Codes Criteria for RO I SRO-I I SRO-U (A)lternate path 4-6 I 4-6 I 2-3 (C)ontrol room (D)irect from bank I 4 (E)mergency or abnormal in-plant 1 I I 1 (EN)gineered safety feature -I -I 1 (control room system (L)ow-Power I Shutdown 1 I I 1 (N)ew or (M)odified from bank including 1 (A) I 1 (P)revious 2 exams 3/ I 2 (randomly selected) (R)CA 1 I I 1 (S)imulator ES-301, Page 23 of 27 ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility:
: k. 300000 K4.02 3.0/3.0 Crosstie U1 and U2 Instrument Air                                   N, E           8
Dresden Date of Examination:
  @       All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
04/06/2015 Exam Level: RO D SRO-I SRO-U D Operating Test Number: 14-1 (2015-301)
* Type *Codes                                   Criteria for RO I SRO-I I SRO-U (A)lternate path                                                     4-6 I   4-6 I 2-3 (C)ontrol room (D)irect from bank                                                   ~9/    ~8    I ~4 (E)mergency or abnormal in-plant                                     ~ 1 I >1 I ~1 (EN)gineered safety feature                                           - I     - I ~ 1 (control room system (L)ow-Power I Shutdown                                               ~ 1 I   ~1    I ~ 1 (N)ew or (M)odified from bank including 1(A)                         ~2/    ~2    I ~ 1 (P)revious 2 exams                                                   ~ 3/   ~3    I ~ 2 (randomly selected)
Control Room Systems@ (8 for RO); (7 for SRO-I}; (2 or 3 for SRO-U, including 1 ESF) System I JPM Title Type Code* Safety Function a. 202001 A4.01 3.7/3.7 ASD -Change Reactor Power With Recirc Flow N,A,S 1 b. 204000 A4.06 3.0/2.9 RWCU -Secure Rapidly During A Transient D, L, S 2 C. d. 203000 A1 .04 3.6/3.6 LPCI -Mitigate high Suction Pressure While D,A,S 4 Lining Up CST Suction For Injection
(R)CA                                                                 ~ 1 I ~1    I ~ 1 (S)imulator ES-301, Page 23 of 27
: e. 223001 A4.07 4.2/4.1 Containment-Vent Torus w/ Valve Failure A,D,S 5 f. 262001 A4.04 3.6/3.7 Aux Power-X-Fer to TR-22 from TR-21 A,D,S 6 g. 215002 A2.05 3.2/3.3 Clear RBM D,P,S 7 h. 290003 A4.01 3.2/3.2 CREV -Secure A AHU and Start B RCU D,S 9 In-Plant Systems@ (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U) i. 204000 K1 .05 3.2/3.3 EDG -Manually fill 2/3 EDG Day Tank D,R 6 j. 207000 A 1.01 3.7/3 .. 8 IC M/U Pump Local Operation w/ Failure A,P 4 k. 300000 K4.02 3.0/3.0 Crosstie U1 and U2 Instrument Air N, E 8 @ All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
 
* Type *Codes Criteria for RO I SRO-I I SRO-U (A)lternate path 4-6 I 4-6 I 2-3 (C)ontrol room (D)irect from bank I (E)mergency or abnormal in-plant 1 I > 1 I 1 (EN)gineered safety feature -I -I 1 (control room system (L)ow-Power I Shutdown 1 I I 1 (N)ew or (M)odified from bank including 1(A) I 1 (P)revious 2 exams 3/ I 2 (randomly selected) (R)CA 1 I I 1 (S)imulator ES-301, Page 23 of 27}}
ES-301                           Administrative Topics Outline                           Form ES-301-1 Facility: Dresden                                                     Date of Examination: 04/06/2014 Examination Level: RO~ SRO         0                                 Operating Test Number:14-1 (2015-301)
Administrative Topic         Type Describe activity to be performed (See Note)               Code*
                                                  \
Review Acceptance Criteria Met For Acoustic Monitor Conduct of Operations              S,D Generic.2.1. 7   4.4/--
U1 & 2/3 CST Inventory Calculations Conduct of Operations              S,D Generic.2.1.18     3.6/--
Identify Requirements For A Valve Stroke Timing Error Equipment Control                S,P,D Generic.2.2.14     3.9/--
Determine Brief And Protective Clothing Requirements Radiation Control                  N,S Generic.2,3. 7   3.5/--
Emergency Procedures/Plan NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when 5 are required.
*Type Codes & Criteria:             (C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank(~  3 for ROs;   ~ 4 for SROs & RO retakes)
(N)ew or (M)odified from bank(~ 1)
(P)revious 2 exams (~ 1; randomly selected)
ES 301, Page 22 of 27
 
ES-301                           Administrative Topics Outline                           Form ES-301-1 Facility: Dresden                                                     Date of Examination: 04/06/2014 Examination Level: RO     0   SRO   IZI                               Operating Test Number:14-1 (2015-301)
Administrative Topic           Type Describe activity to be performed (See Note)               Code*
Reportability determination - Contaminated Worker Conduct of Operations               S,D Generic.2.1.1   /4.2 Determination of On-Line Risk Conduct of Operations               S,N Generic.2.1.19   /3.8 Verify Reversal Of EOG Cooling Water Flow Surveillance Equipment Control                    S,D Generic.2.2.12   /4.1 Select Personnel For Radiation Work Radiation Control                 S,P,D Generic.2.3.13   /3.8 Determination Of EP Classification And Fill Out NARS Emergency Procedures/Plan           S,N       Form Generic.2.4.44   /4.4 NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when 5 are required.
* Type Codes & Criteria:             (C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank(~ 3 for ROs; ~ 4 for SROs & RO retakes)
(N)ew or (M)odified from bank (2: 1)
(P)revious 2 exams (~ 1; randomly selected)
ES 301, Page 22 of 27
 
ES-301                           Control Room/In-Plant Systems Outline                             Form ES-301-2 Facility: Dresden                                                       Date of Examination: 04/06/2015 Exam Level: RO ~ SRO-I         D   SRO-U   D                         Operating Test Number: 14-1 (2015-301}
Control Room Systems@ (8 for RO); (7 for SRO-I); (2 or 3 for SRO-U, including 1 ESF)
Safety System I JPM Title                                       Type Code*
Function
: a. 202001 A4.01 3.7/3.7 ASD - Change Reactor Power With Recirc Flow                       N, A, S           1
: b. 204000 A4.06 3.0/2.9 RWCU - Secure Rapidly During A Transient                           D,L,S           2
: c. 241000 A4.06 3.9/3.9 DEHC- Establish RPV Cooldown w/ Bypass                             D, L, S         3 Valves
: d. 203000 A1 .04 3.6/3.6 LPCI - Mitigate high Suction Pressure While                       D,A,S           4 Lining Up CST Suction For Injection
: e. 223001 A4.07 4.2/4.1 Containment - Vent Torus w/ Valve Failure                         A,D,S             5
: f. 262001 A4.04 3.6/3. 7 Aux Power - X-Fer to TR-22 from TR-21                             A,D,S             6
: g. 215002 A2.05 3.2/3.3 Clear RBM                                                           D,P,S           7
: h. 290003 A4.01 3.2/3.2 CREV - Secure A AHU and Start B RCU                                 D,S             9 In-Plant Systems@ (3 for RO); (3 for SRO-I}; (3 or 2 for SRO-U)
: i. 264000 K1 .05 3.2/3.3 EDG - Manually fill 2/3 EDG Day Tank                               D,R             6
: j. 207000 A 1.01 3. 7/3.8 IC M/U Pump Local Operation w/ Failure                             A,P             4
: k. 300000 K4.02 3.0/3.0 Crosstie U1 and U2 Instrument Air                                   N,E             8
  @       All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
                  *Type Codes                                     Criteria for RO I SRO-I I SRO-U (A)lternate path                                                     4-6 I   4-6 I 2-3 (C)ontrol room (D)irect from bank                                                   ~9/    ~8    I ~4 (E)mergency or abnormal in-plant                                     ~ 1 I ~1    I ~ 1 (EN)gineered safety feature                                           - I     -   I ~ 1 (control room system (L)ow-Power I Shutdown                                               ~ 1 I   ~1    I ~ 1 (N)ew or (M)odified from bank including 1(A)                         ~21    ~2    I ~ 1 (P)revious 2 exams                                                   ~ 3/   ~3    I ~ 2 (randomly selected)
(R)CA                                                                 ~ 1 I ~1    I ~ 1 (S)imulator ES-301, Page 23 of 27
 
ES-301                           Control Room/In-Plant Systems Outline                           Form ES-301-2 Facility: Dresden                                                       Date of Examination: 04/06/2015 Exam Level: RO       D   SRO-I ~ SRO-U       D                       Operating Test Number: 14-1 (2015-301)
Control Room Systems@ (8 for RO); (7 for SRO-I}; (2 or 3 for SRO-U, including 1 ESF)
Safety System I JPM Title                                     Type Code*
Function
: a. 202001 A4.01 3.7/3.7 ASD - Change Reactor Power With Recirc Flow                         N,A,S             1
: b. 204000 A4.06 3.0/2.9 RWCU - Secure Rapidly During A Transient                           D, L, S         2 C.
: d. 203000 A1 .04 3.6/3.6 LPCI - Mitigate high Suction Pressure While                       D,A,S           4 Lining Up CST Suction For Injection
: e. 223001 A4.07 4.2/4.1 Containment-Vent Torus w/ Valve Failure                           A,D,S             5
: f. 262001 A4.04 3.6/3.7 Aux Power- X-Fer to TR-22 from TR-21                               A,D,S             6
: g. 215002 A2.05 3.2/3.3 Clear RBM                                                           D,P,S             7
: h. 290003 A4.01 3.2/3.2 CREV - Secure A AHU and Start B RCU                                 D,S             9 In-Plant Systems@ (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)
: i. 204000 K1 .05 3.2/3.3 EDG - Manually fill 2/3 EDG Day Tank                               D,R             6
: j. 207000 A 1.01 3.7/3 ..8 IC M/U Pump Local Operation w/ Failure                           A,P             4
: k. 300000 K4.02 3.0/3.0 Crosstie U1 and U2 Instrument Air                                   N, E           8
  @       All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
* Type *Codes                                   Criteria for RO I SRO-I I SRO-U (A)lternate path                                                     4-6 I   4-6 I 2-3 (C)ontrol room (D)irect from bank                                                   ~9/    ~8    I ~4 (E)mergency or abnormal in-plant                                     ~ 1 I >1 I ~1 (EN)gineered safety feature                                           - I     - I ~ 1 (control room system (L)ow-Power I Shutdown                                               ~ 1 I   ~1    I ~ 1 (N)ew or (M)odified from bank including 1(A)                         ~2/    ~2    I ~ 1 (P)revious 2 exams                                                   ~ 3/   ~3    I ~ 2 (randomly selected)
(R)CA                                                                 ~ 1 I ~1    I ~ 1 (S)imulator ES-301, Page 23 of 27}}

Latest revision as of 06:43, 31 October 2019

2015 Dresden Station Initial License Examination Forms ES-301-1 and ES-301-2
ML15287A267
Person / Time
Site: Dresden  Constellation icon.png
Issue date: 04/30/2015
From: Randy Baker
Operations Branch III
To:
Exelon Generation Co
Shared Package
ML14337A718 List:
References
Download: ML15287A267 (4)


Text

ES-301 Administrative Topics Outline Form ES-301-1 Facility: Dresden Date of Examination: 04/06/2014 Examination Level: RO~ SRO 0 Operating Test Number:14-1 (2015-301)

Administrative Topic Type Describe activity to be performed (See Note) Code*

\

Review Acceptance Criteria Met For Acoustic Monitor Conduct of Operations S,D Generic.2.1. 7 4.4/--

U1 & 2/3 CST Inventory Calculations Conduct of Operations S,D Generic.2.1.18 3.6/--

Identify Requirements For A Valve Stroke Timing Error Equipment Control S,P,D Generic.2.2.14 3.9/--

Determine Brief And Protective Clothing Requirements Radiation Control N,S Generic.2,3. 7 3.5/--

Emergency Procedures/Plan NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when 5 are required.

  • Type Codes & Criteria: (C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank(~ 3 for ROs; ~ 4 for SROs & RO retakes)

(N)ew or (M)odified from bank(~ 1)

(P)revious 2 exams (~ 1; randomly selected)

ES 301, Page 22 of 27

ES-301 Administrative Topics Outline Form ES-301-1 Facility: Dresden Date of Examination: 04/06/2014 Examination Level: RO 0 SRO IZI Operating Test Number:14-1 (2015-301)

Administrative Topic Type Describe activity to be performed (See Note) Code*

Reportability determination - Contaminated Worker Conduct of Operations S,D Generic.2.1.1 /4.2 Determination of On-Line Risk Conduct of Operations S,N Generic.2.1.19 /3.8 Verify Reversal Of EOG Cooling Water Flow Surveillance Equipment Control S,D Generic.2.2.12 /4.1 Select Personnel For Radiation Work Radiation Control S,P,D Generic.2.3.13 /3.8 Determination Of EP Classification And Fill Out NARS Emergency Procedures/Plan S,N Form Generic.2.4.44 /4.4 NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when 5 are required.

  • Type Codes & Criteria: (C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank(~ 3 for ROs; ~ 4 for SROs & RO retakes)

(N)ew or (M)odified from bank (2: 1)

(P)revious 2 exams (~ 1; randomly selected)

ES 301, Page 22 of 27

ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility: Dresden Date of Examination: 04/06/2015 Exam Level: RO ~ SRO-I D SRO-U D Operating Test Number: 14-1 (2015-301}

Control Room Systems@ (8 for RO); (7 for SRO-I); (2 or 3 for SRO-U, including 1 ESF)

Safety System I JPM Title Type Code*

Function

a. 202001 A4.01 3.7/3.7 ASD - Change Reactor Power With Recirc Flow N, A, S 1
b. 204000 A4.06 3.0/2.9 RWCU - Secure Rapidly During A Transient D,L,S 2
c. 241000 A4.06 3.9/3.9 DEHC- Establish RPV Cooldown w/ Bypass D, L, S 3 Valves
d. 203000 A1 .04 3.6/3.6 LPCI - Mitigate high Suction Pressure While D,A,S 4 Lining Up CST Suction For Injection
e. 223001 A4.07 4.2/4.1 Containment - Vent Torus w/ Valve Failure A,D,S 5
f. 262001 A4.04 3.6/3. 7 Aux Power - X-Fer to TR-22 from TR-21 A,D,S 6
g. 215002 A2.05 3.2/3.3 Clear RBM D,P,S 7
h. 290003 A4.01 3.2/3.2 CREV - Secure A AHU and Start B RCU D,S 9 In-Plant Systems@ (3 for RO); (3 for SRO-I}; (3 or 2 for SRO-U)
i. 264000 K1 .05 3.2/3.3 EDG - Manually fill 2/3 EDG Day Tank D,R 6
j. 207000 A 1.01 3. 7/3.8 IC M/U Pump Local Operation w/ Failure A,P 4
k. 300000 K4.02 3.0/3.0 Crosstie U1 and U2 Instrument Air N,E 8

@ All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.

  • Type Codes Criteria for RO I SRO-I I SRO-U (A)lternate path 4-6 I 4-6 I 2-3 (C)ontrol room (D)irect from bank ~9/ ~8 I ~4 (E)mergency or abnormal in-plant ~ 1 I ~1 I ~ 1 (EN)gineered safety feature - I - I ~ 1 (control room system (L)ow-Power I Shutdown ~ 1 I ~1 I ~ 1 (N)ew or (M)odified from bank including 1(A) ~21 ~2 I ~ 1 (P)revious 2 exams ~ 3/ ~3 I ~ 2 (randomly selected)

(R)CA ~ 1 I ~1 I ~ 1 (S)imulator ES-301, Page 23 of 27

ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility: Dresden Date of Examination: 04/06/2015 Exam Level: RO D SRO-I ~ SRO-U D Operating Test Number: 14-1 (2015-301)

Control Room Systems@ (8 for RO); (7 for SRO-I}; (2 or 3 for SRO-U, including 1 ESF)

Safety System I JPM Title Type Code*

Function

a. 202001 A4.01 3.7/3.7 ASD - Change Reactor Power With Recirc Flow N,A,S 1
b. 204000 A4.06 3.0/2.9 RWCU - Secure Rapidly During A Transient D, L, S 2 C.
d. 203000 A1 .04 3.6/3.6 LPCI - Mitigate high Suction Pressure While D,A,S 4 Lining Up CST Suction For Injection
e. 223001 A4.07 4.2/4.1 Containment-Vent Torus w/ Valve Failure A,D,S 5
f. 262001 A4.04 3.6/3.7 Aux Power- X-Fer to TR-22 from TR-21 A,D,S 6
g. 215002 A2.05 3.2/3.3 Clear RBM D,P,S 7
h. 290003 A4.01 3.2/3.2 CREV - Secure A AHU and Start B RCU D,S 9 In-Plant Systems@ (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)
i. 204000 K1 .05 3.2/3.3 EDG - Manually fill 2/3 EDG Day Tank D,R 6
j. 207000 A 1.01 3.7/3 ..8 IC M/U Pump Local Operation w/ Failure A,P 4
k. 300000 K4.02 3.0/3.0 Crosstie U1 and U2 Instrument Air N, E 8

@ All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.

  • Type *Codes Criteria for RO I SRO-I I SRO-U (A)lternate path 4-6 I 4-6 I 2-3 (C)ontrol room (D)irect from bank ~9/ ~8 I ~4 (E)mergency or abnormal in-plant ~ 1 I >1 I ~1 (EN)gineered safety feature - I - I ~ 1 (control room system (L)ow-Power I Shutdown ~ 1 I ~1 I ~ 1 (N)ew or (M)odified from bank including 1(A) ~2/ ~2 I ~ 1 (P)revious 2 exams ~ 3/ ~3 I ~ 2 (randomly selected)

(R)CA ~ 1 I ~1 I ~ 1 (S)imulator ES-301, Page 23 of 27

ES-301 Administrative Topics Outline Form ES-301-1 Facility: Dresden Date of Examination: 04/06/2014 Examination Level: RO~ SRO 0 Operating Test Number:14-1 (2015-301)

Administrative Topic Type Describe activity to be performed (See Note) Code*

\

Review Acceptance Criteria Met For Acoustic Monitor Conduct of Operations S,D Generic.2.1. 7 4.4/--

U1 & 2/3 CST Inventory Calculations Conduct of Operations S,D Generic.2.1.18 3.6/--

Identify Requirements For A Valve Stroke Timing Error Equipment Control S,P,D Generic.2.2.14 3.9/--

Determine Brief And Protective Clothing Requirements Radiation Control N,S Generic.2,3. 7 3.5/--

Emergency Procedures/Plan NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when 5 are required.

  • Type Codes & Criteria: (C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank(~ 3 for ROs; ~ 4 for SROs & RO retakes)

(N)ew or (M)odified from bank(~ 1)

(P)revious 2 exams (~ 1; randomly selected)

ES 301, Page 22 of 27

ES-301 Administrative Topics Outline Form ES-301-1 Facility: Dresden Date of Examination: 04/06/2014 Examination Level: RO 0 SRO IZI Operating Test Number:14-1 (2015-301)

Administrative Topic Type Describe activity to be performed (See Note) Code*

Reportability determination - Contaminated Worker Conduct of Operations S,D Generic.2.1.1 /4.2 Determination of On-Line Risk Conduct of Operations S,N Generic.2.1.19 /3.8 Verify Reversal Of EOG Cooling Water Flow Surveillance Equipment Control S,D Generic.2.2.12 /4.1 Select Personnel For Radiation Work Radiation Control S,P,D Generic.2.3.13 /3.8 Determination Of EP Classification And Fill Out NARS Emergency Procedures/Plan S,N Form Generic.2.4.44 /4.4 NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when 5 are required.

  • Type Codes & Criteria: (C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank(~ 3 for ROs; ~ 4 for SROs & RO retakes)

(N)ew or (M)odified from bank (2: 1)

(P)revious 2 exams (~ 1; randomly selected)

ES 301, Page 22 of 27

ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility: Dresden Date of Examination: 04/06/2015 Exam Level: RO ~ SRO-I D SRO-U D Operating Test Number: 14-1 (2015-301}

Control Room Systems@ (8 for RO); (7 for SRO-I); (2 or 3 for SRO-U, including 1 ESF)

Safety System I JPM Title Type Code*

Function

a. 202001 A4.01 3.7/3.7 ASD - Change Reactor Power With Recirc Flow N, A, S 1
b. 204000 A4.06 3.0/2.9 RWCU - Secure Rapidly During A Transient D,L,S 2
c. 241000 A4.06 3.9/3.9 DEHC- Establish RPV Cooldown w/ Bypass D, L, S 3 Valves
d. 203000 A1 .04 3.6/3.6 LPCI - Mitigate high Suction Pressure While D,A,S 4 Lining Up CST Suction For Injection
e. 223001 A4.07 4.2/4.1 Containment - Vent Torus w/ Valve Failure A,D,S 5
f. 262001 A4.04 3.6/3. 7 Aux Power - X-Fer to TR-22 from TR-21 A,D,S 6
g. 215002 A2.05 3.2/3.3 Clear RBM D,P,S 7
h. 290003 A4.01 3.2/3.2 CREV - Secure A AHU and Start B RCU D,S 9 In-Plant Systems@ (3 for RO); (3 for SRO-I}; (3 or 2 for SRO-U)
i. 264000 K1 .05 3.2/3.3 EDG - Manually fill 2/3 EDG Day Tank D,R 6
j. 207000 A 1.01 3. 7/3.8 IC M/U Pump Local Operation w/ Failure A,P 4
k. 300000 K4.02 3.0/3.0 Crosstie U1 and U2 Instrument Air N,E 8

@ All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.

  • Type Codes Criteria for RO I SRO-I I SRO-U (A)lternate path 4-6 I 4-6 I 2-3 (C)ontrol room (D)irect from bank ~9/ ~8 I ~4 (E)mergency or abnormal in-plant ~ 1 I ~1 I ~ 1 (EN)gineered safety feature - I - I ~ 1 (control room system (L)ow-Power I Shutdown ~ 1 I ~1 I ~ 1 (N)ew or (M)odified from bank including 1(A) ~21 ~2 I ~ 1 (P)revious 2 exams ~ 3/ ~3 I ~ 2 (randomly selected)

(R)CA ~ 1 I ~1 I ~ 1 (S)imulator ES-301, Page 23 of 27

ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility: Dresden Date of Examination: 04/06/2015 Exam Level: RO D SRO-I ~ SRO-U D Operating Test Number: 14-1 (2015-301)

Control Room Systems@ (8 for RO); (7 for SRO-I}; (2 or 3 for SRO-U, including 1 ESF)

Safety System I JPM Title Type Code*

Function

a. 202001 A4.01 3.7/3.7 ASD - Change Reactor Power With Recirc Flow N,A,S 1
b. 204000 A4.06 3.0/2.9 RWCU - Secure Rapidly During A Transient D, L, S 2 C.
d. 203000 A1 .04 3.6/3.6 LPCI - Mitigate high Suction Pressure While D,A,S 4 Lining Up CST Suction For Injection
e. 223001 A4.07 4.2/4.1 Containment-Vent Torus w/ Valve Failure A,D,S 5
f. 262001 A4.04 3.6/3.7 Aux Power- X-Fer to TR-22 from TR-21 A,D,S 6
g. 215002 A2.05 3.2/3.3 Clear RBM D,P,S 7
h. 290003 A4.01 3.2/3.2 CREV - Secure A AHU and Start B RCU D,S 9 In-Plant Systems@ (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)
i. 204000 K1 .05 3.2/3.3 EDG - Manually fill 2/3 EDG Day Tank D,R 6
j. 207000 A 1.01 3.7/3 ..8 IC M/U Pump Local Operation w/ Failure A,P 4
k. 300000 K4.02 3.0/3.0 Crosstie U1 and U2 Instrument Air N, E 8

@ All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.

  • Type *Codes Criteria for RO I SRO-I I SRO-U (A)lternate path 4-6 I 4-6 I 2-3 (C)ontrol room (D)irect from bank ~9/ ~8 I ~4 (E)mergency or abnormal in-plant ~ 1 I >1 I ~1 (EN)gineered safety feature - I - I ~ 1 (control room system (L)ow-Power I Shutdown ~ 1 I ~1 I ~ 1 (N)ew or (M)odified from bank including 1(A) ~2/ ~2 I ~ 1 (P)revious 2 exams ~ 3/ ~3 I ~ 2 (randomly selected)

(R)CA ~ 1 I ~1 I ~ 1 (S)imulator ES-301, Page 23 of 27