{{#Wiki_filter: | {{#Wiki_filter:ATTACHMENT 1 Consumers Power Company Palisades Plant Docket 50-255 PAGE CHANGES November 20, 1990 | ||
' ~~* ~ . | |||
TABLE 3 *. 6. I CONTAINMENT PENETRATIONS AND VALVES SYSTEM NAME AND VALVE PEN NUMBER SERVICE LINE SIZE ID NO REMARKS IA PURGE AIR EXHAUST CV-I805 Auto isolation. | 2 Pages | ||
valve; .(8") CV-I806 required closure time = 25 seconds IC PURGE AIR EXHAUST CV-I807 Auto isolation valve; (8") CV-I808 required closure time = 25 seconds 5 S/G (E-50A) cv:..0161 Auto isolation valve; | :( 9611280024 901120 ' | ||
* time 25 seconds 6 S/G (E-508) CV-0768 Auto isolation valve; SLOWDOWN CV-0770 required closure ( 4") | PDR ADOCK 05000255* I I' P PDC i | ||
* time.= 25 seconds 11 CONDENSATE TO CV-0939 Auto isolation valve; SHIELD COOLING CK-CD40l required closure SURGE TANK time = 25 seconds (I %") 14 COMPONENT COOLING CV-09IO Auto isolation valve; WATER IN (IO") CK-CC09IO required closure time = 25 seconds I5 COMPONENT COOLING CV-0911 Auto isolation valve; WATER OUT (IO") CV-0940 required closure time = 25 seconds 16 S/G (E-50A) CV-0739 . Auto isolation valve; RECIRCULATION required *closure ( 4") | J | ||
* time = 25 seconds *Penetration line size; isolation valves are 2-inch. 3-40b Amendment No. | |||
TSPR9007 | TABLE 3 *. 6. I CONTAINMENT PENETRATIONS AND VALVES SYSTEM NAME AND VALVE PEN NUMBER SERVICE LINE SIZE ID NO REMARKS IA PURGE AIR EXHAUST CV-I805 Auto isolation. valve; | ||
SYSTEM NAME AND PEN NUMBER SERVICE LINE SIZE 47 | .(8") CV-I806 required closure time = 25 seconds IC PURGE AIR EXHAUST CV-I807 Auto isolation valve; (8") CV-I808 required closure time = 25 seconds 5 S/G (E-50A) | ||
SLOWDOWN cv:..0161 CV-0771 Auto isolation valve; required closure e | |||
*I | (4") | ||
* time ~ 25 seconds I 6 S/G (E-508) CV-0768 Auto isolation valve; SLOWDOWN CV-0770 required closure (4") | |||
* time.= 25 seconds 11 CONDENSATE TO CV-0939 Auto isolation valve; SHIELD COOLING CK-CD40l required closure SURGE TANK time = 25 seconds (I %") | |||
* | 14 COMPONENT COOLING CV-09IO Auto isolation valve; WATER IN (IO") CK-CC09IO required closure time = 25 seconds I5 COMPONENT COOLING CV-0911 Auto isolation valve; WATER OUT (IO") CV-0940 required closure time = 25 seconds 16 S/G (E-50A) CV-0739 . Auto isolation valve; RECIRCULATION required *closure (4") | ||
* time = 25 seconds | |||
* 25 seconds | *Penetration line size; isolation valves are 2-inch. | ||
* | 3-40b Amendment No. Ji~, | ||
* | TSPR9007 | ||
* 25 seconds Auto isolation valve; required closure time | |||
* 25 seconds | TABLE 3.6.1 CONTAINMENT PENETRATIONS AND VALVES SYSTEM NAME AND VALVE PEN NUMBER SERVICE LINE SIZE ID NO REMARKS 47 PRIMARY SYSTEM CV-1002 Auto isolation valve; DRAIN TANK PUMP CV-1007 . required closure SUCTION (4"} time = 25 seconds 49 CLEAN WASTE CV-1038 Auto isolation valve; RECEIVER TANK CV-1036 required closure CIRCULATION PUMP time = 25 seconds SUCTION (3"} | ||
52 CONTAINMENT SUMP CV-1103 Auto isolation valve; DRAIN TO DIRTY.WASTE CV-1104 required closure TANK (4"} time = 25 seconds 55 S/G (E-SOB} CV-0738 Auto isolation valve; RECIRCULATION (4"}* required closure time = 25 seconds 67 CLEAN WASTE CV-1037 Auto isolation valve; RECEIVER TANK PUMP CK-CRW408 required closure RECIRC (3"} time = 25 seconds 68 AIR SUPPLY TO CV-1813 Auto isolation valve; AIR ROOM ( 12 II } CV-1814 required closure time = 25 seconds 69 CLEAN WASTE CV-1045 Auto isolation valve; RECEIVER TANK PUMP CV-1044 required closure SUCTION (4''.} time = 25 seconds | |||
*Penetration line size; isolation valves are 2-inch. | |||
3-40e Amendment No. Ji~, | |||
TSPR9007 | |||
ATTACHMENT 2 | |||
*I Consumers Power Company Palisades Plant Docket 50-255 | |||
**MARKED UP,TECHNICAL SPEC1~ICATION PAGES | |||
_November 20, 1990 2 Pages | |||
TABLE 3.6.1 CONTAINMENT PENETRATIONS AND VALVES SYS'lEH NAME AND VALVE PEN NUMBER SERVICE LINE SIZE ID NO REMARKS 1A CV-1805 Auto isolation valve;* | |||
CV-1806 required closure* | |||
time | |||
* 25 seconds PURGE* AIR ~UST CV-1807 Auto isolation valve; (8") . > ' ...... ' *..* . CV-1808 required closure time | |||
* 25 seconds 5 CV-0767 Auto isolation valve; CV-0771 required closure time | |||
* 25 seconds I I | |||
6 S/G (E-50B) CV-0768 Auto isolation va,lve; Bm'TeH BLOWDOWN CV-0770 required closure | |||
(.2d)(~4") | |||
* time | * time | ||
* 25 .seconds Auto valve; : required closure time | * 25 seconds 11 CONDENSAD TO CV-0939 Auto isolation valve; SHIELD COOLING CK-CD401 required closure SURGE IANK time | ||
* 25 | * 25 seconds (1 1/211 ) | ||
* Au.to isolation* | 14 COMPONEN'I COOLING CV-0910 . Auto isolation valve; WADR IN (1011 ) . CK-CC0910 required closure* | ||
valve; . required closure. * | tiine | ||
* 25 seconds .3-40e Amendment No. lf3E --5eptemlleF | * 25 seconds 15 OOHPONENT COOLING CV-0911 Auto isolation valve; WAl'ER OU'r ( 10") CV-0940 required closure time | ||
§, 1989'- | * 25 seconds 16 S/G (E-50A) CV-0739 Auto isolation valve; SURF#££ BbeWBeWN Jl£L:,,/ ~~L~T"l'O~ required closure | ||
. CY> C~'') ~ ' time | |||
* 25 seconds | |||
.,, 1 I | |||
3-40b Amendment No. ,(Zg' September §, 1989 | |||
*~ ...*0689-0136-NL04 | |||
* TABLE 3.6.1 , | |||
CONTAINMENT PENETRATIONS AND VALVES SYSTEM NAME AND VALVE PEN NUMBER SERVICE. LINE. | |||
,l ;*, | |||
SIZE ID NO REMARKS 47 cv-1002 Auto isolation valve; CV-1007 required closure time | |||
* 25 seconds 49 CLEAN WAS'IE CV-1038 Auto isolation*valve; RECEIVEJ( TANK CV-103~ | |||
* re9uired closure CIRCULAnON'PUMP. tlme | |||
* 25 seconds SUC'IlON (3'') '. : | |||
52 CONTAINMENT SUMP CV-1103 . Auto isolation valve; . | |||
DRAIN TO DIRTY WASl'E CV-1104 required closure TANK (411 ) . time - 25 seCO?dS I | |||
55 S/G (E-50B) :S\JR¥MB! | |||
* CV-0738 Auto isolatiQn valve; | |||
==BOOl1IOOWlt (2 1 ' ~~.if!!.C.U<:.-4-TlD~ . required cl0sure | |||
(¥"")* time* *2~.s~q~~s 67 CLEAN WAS1'E cv-1031* . Auto isolation' valve; RECEIVER TANK PUMP CK-cRW408 required ~l~~ure | |||
* RECIRC (3") . time | |||
* 25 .seconds 68 . AIR SUPPLY TO AIR ROOM (1211 ) | |||
CV-1813 cv-J114 Auto isol~~ton valve; | |||
: required closure time | |||
* 25 *s~cond~ | |||
e* | |||
69 CLEAN WASTE CV-1045 Au.to isolation* valve; RECEIVER TANK PUMP CV-l041t . required closure. | |||
SUC'l'ION (4") | |||
* t~ | |||
* 25 seconds | |||
.3-40e Amendment No. lf3E | |||
--5eptemlleF §, 1989'- | |||
TSP0689-0136-NL04}} |
Latest revision as of 16:13, 23 February 2020
ML18057A595 | |
Person / Time | |
---|---|
Site: | Palisades |
Issue date: | 11/20/1990 |
From: | CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.) |
To: | |
Shared Package | |
ML18057A594 | List: |
References | |
NUDOCS 9011280024 | |
Download: ML18057A595 (6) | |
Text
ATTACHMENT 1 Consumers Power Company Palisades Plant Docket 50-255 PAGE CHANGES November 20, 1990
' ~~* ~ .
2 Pages
- ( 9611280024 901120 '
PDR ADOCK 05000255* I I' P PDC i
J
TABLE 3 *. 6. I CONTAINMENT PENETRATIONS AND VALVES SYSTEM NAME AND VALVE PEN NUMBER SERVICE LINE SIZE ID NO REMARKS IA PURGE AIR EXHAUST CV-I805 Auto isolation. valve;
.(8") CV-I806 required closure time = 25 seconds IC PURGE AIR EXHAUST CV-I807 Auto isolation valve; (8") CV-I808 required closure time = 25 seconds 5 S/G (E-50A)
SLOWDOWN cv:..0161 CV-0771 Auto isolation valve; required closure e
(4")
- time ~ 25 seconds I 6 S/G (E-508) CV-0768 Auto isolation valve; SLOWDOWN CV-0770 required closure (4")
- time.= 25 seconds 11 CONDENSATE TO CV-0939 Auto isolation valve; SHIELD COOLING CK-CD40l required closure SURGE TANK time = 25 seconds (I %")
14 COMPONENT COOLING CV-09IO Auto isolation valve; WATER IN (IO") CK-CC09IO required closure time = 25 seconds I5 COMPONENT COOLING CV-0911 Auto isolation valve; WATER OUT (IO") CV-0940 required closure time = 25 seconds 16 S/G (E-50A) CV-0739 . Auto isolation valve; RECIRCULATION required *closure (4")
- time = 25 seconds
- Penetration line size; isolation valves are 2-inch.
3-40b Amendment No. Ji~,
TSPR9007
TABLE 3.6.1 CONTAINMENT PENETRATIONS AND VALVES SYSTEM NAME AND VALVE PEN NUMBER SERVICE LINE SIZE ID NO REMARKS 47 PRIMARY SYSTEM CV-1002 Auto isolation valve; DRAIN TANK PUMP CV-1007 . required closure SUCTION (4"} time = 25 seconds 49 CLEAN WASTE CV-1038 Auto isolation valve; RECEIVER TANK CV-1036 required closure CIRCULATION PUMP time = 25 seconds SUCTION (3"}
52 CONTAINMENT SUMP CV-1103 Auto isolation valve; DRAIN TO DIRTY.WASTE CV-1104 required closure TANK (4"} time = 25 seconds 55 S/G (E-SOB} CV-0738 Auto isolation valve; RECIRCULATION (4"}* required closure time = 25 seconds 67 CLEAN WASTE CV-1037 Auto isolation valve; RECEIVER TANK PUMP CK-CRW408 required closure RECIRC (3"} time = 25 seconds 68 AIR SUPPLY TO CV-1813 Auto isolation valve; AIR ROOM ( 12 II } CV-1814 required closure time = 25 seconds 69 CLEAN WASTE CV-1045 Auto isolation valve; RECEIVER TANK PUMP CV-1044 required closure SUCTION (4.} time = 25 seconds
- Penetration line size; isolation valves are 2-inch.
3-40e Amendment No. Ji~,
TSPR9007
ATTACHMENT 2
- I Consumers Power Company Palisades Plant Docket 50-255
- MARKED UP,TECHNICAL SPEC1~ICATION PAGES
_November 20, 1990 2 Pages
TABLE 3.6.1 CONTAINMENT PENETRATIONS AND VALVES SYS'lEH NAME AND VALVE PEN NUMBER SERVICE LINE SIZE ID NO REMARKS 1A CV-1805 Auto isolation valve;*
CV-1806 required closure*
time
- 25 seconds PURGE* AIR ~UST CV-1807 Auto isolation valve; (8") . > ' ...... ' *..* . CV-1808 required closure time
- 25 seconds 5 CV-0767 Auto isolation valve; CV-0771 required closure time
- 25 seconds I I
6 S/G (E-50B) CV-0768 Auto isolation va,lve; Bm'TeH BLOWDOWN CV-0770 required closure
(.2d)(~4")
- time
- 25 seconds 11 CONDENSAD TO CV-0939 Auto isolation valve; SHIELD COOLING CK-CD401 required closure SURGE IANK time
- 25 seconds (1 1/211 )
14 COMPONEN'I COOLING CV-0910 . Auto isolation valve; WADR IN (1011 ) . CK-CC0910 required closure*
tiine
- 25 seconds 15 OOHPONENT COOLING CV-0911 Auto isolation valve; WAl'ER OU'r ( 10") CV-0940 required closure time
- 25 seconds 16 S/G (E-50A) CV-0739 Auto isolation valve; SURF#££ BbeWBeWN Jl£L:,,/ ~~L~T"l'O~ required closure
. CY> C~) ~ ' time
- 25 seconds
.,, 1 I
3-40b Amendment No. ,(Zg' September §, 1989
- ~ ...*0689-0136-NL04
- TABLE 3.6.1 ,
CONTAINMENT PENETRATIONS AND VALVES SYSTEM NAME AND VALVE PEN NUMBER SERVICE. LINE.
,l ;*,
SIZE ID NO REMARKS 47 cv-1002 Auto isolation valve; CV-1007 required closure time
- 25 seconds 49 CLEAN WAS'IE CV-1038 Auto isolation*valve; RECEIVEJ( TANK CV-103~
- re9uired closure CIRCULAnON'PUMP. tlme
- 25 seconds SUC'IlON (3) '. :
52 CONTAINMENT SUMP CV-1103 . Auto isolation valve; .
DRAIN TO DIRTY WASl'E CV-1104 required closure TANK (411 ) . time - 25 seCO?dS I
55 S/G (E-50B) :S\JR¥MB!
- CV-0738 Auto isolatiQn valve;
==BOOl1IOOWlt (2 1 ' ~~.if!!.C.U<:.-4-TlD~ . required cl0sure
(¥"")* time* *2~.s~q~~s 67 CLEAN WAS1'E cv-1031* . Auto isolation' valve; RECEIVER TANK PUMP CK-cRW408 required ~l~~ure
- RECIRC (3") . time
- 25 .seconds 68 . AIR SUPPLY TO AIR ROOM (1211 )
CV-1813 cv-J114 Auto isol~~ton valve;
- required closure time
- 25 *s~cond~
e*
69 CLEAN WASTE CV-1045 Au.to isolation* valve; RECEIVER TANK PUMP CV-l041t . required closure.
SUC'l'ION (4")
- t~
- 25 seconds
.3-40e Amendment No. lf3E
--5eptemlleF §, 1989'-
TSP0689-0136-NL04