{{#Wiki_filter:L-96-333Attachment 3ATTACHMENT 3ST.LUCIEUNIT1MARKED-UP TECHNICAL SPECIFICATION PAGEPage,2-19612270074 96i220VDRaDOCXOS000SS5PPDR
{{#Wiki_filter:L-96-333 Attachment 3 ATTACHMENT 3 ST.LUCIE UNIT 1 MARKED-UP TECHNICAL SPECIFICATION PAGE Page,2-1 9612270074 96i220 VDR aDOCX OS000SS5 P PDR
~~II2.0SAFETYLIMITSANOLIMITINGSAFETYSYSTENSETTINGS2.1SAFETYLIMITSREACTORCORE~gL.fIp$gEgas&2.1.1Thecombfnatfon ofTHERMALPNER,pressurfzer
~~I I 2.0 SAFETY LIMITS ANO LIMITING SAFETY SYSTEN SETTINGS 2.1 SAFETY LIMITS REACTOR CORE~gL.f I p$gE g as&2.1.1 The combfnatfon of THERMAL PNER, pressurfzer pressure, and maxf-axan cold leg coolant temperature shall not exceed the lfmfts shown on Ff gure 2.1-1.APPLICABILITY:
: pressure, andmaxf-axancoldlegcoolanttemperature shallnotexceedthelfmftsshownonFfgure2.1-1.APPLICABILITY:
MODES 1 and 2.ACTION: Whenever the point defined by the combfnatfon of maxfnam cold leg tetnper-ature and THERMAL POWER has exceeded the appropriate pressurizer pressure line, be in HOT STANDBY within 1 hour.REACTOR COOLANT SYSTEM PRESSURE 2.1.2 The Reactor Coolant System pressure shall not exceed 2750 psfa.APPLICABILITY:
MODES1and2.ACTION:Wheneverthepointdefinedbythecombfnatfon ofmaxfnamcoldlegtetnper-atureandTHERMALPOWERhasexceededtheappropriate pressurizer pressureline,beinHOTSTANDBYwithin1hour.REACTORCOOLANTSYSTEMPRESSURE2.1.2TheReactorCoolantSystempressureshallnotexceed2750psfa.APPLICABILITY:
MODES 1, 2, 3, 4 and 5.ACTION: MODES 1 and 2 Whenever the Reactor Coolant System pressure has exceeded 2750 psfa, be in HOT STANDBY with the Reactor Coolant System pressure within its limit within 1 hour.MODES 3, 4 and 5 Whenever the Reactor Coolant System pressure has exceeded 2750 psfa, reduce the Reactor Coolant System pressure to within its limit within 5 minutes.Qt" L]=lE Amendment No.ST.LUCIE-UNIT 1 2-1 L-96-333 Enclosure ENCLOSURE Siemens Power Corporation-Nuclear Division Report EMF-96-176, Revision 1 St.Lucie Unit 1 Small Break LOCA Analysis with 30%Steam Generator Tube Plugging December 1996}}
MODES1,2,3,4and5.ACTION:MODES1and2WhenevertheReactorCoolantSystempressurehasexceeded2750psfa,beinHOTSTANDBYwiththeReactorCoolantSystempressurewithinitslimitwithin1hour.MODES3,4and5WhenevertheReactorCoolantSystempressurehasexceeded2750psfa,reducetheReactorCoolantSystempressuretowithinitslimitwithin5minutes.Qt"L]=lEAmendment No.ST.LUCIE-UNIT12-1 L-96-333Enclosure ENCLOSURE SiemensPowerCorporation-Nuclear DivisionReportEMF-96-176, Revision1St.LucieUnit1SmallBreakLOCAAnalysiswith30%SteamGenerator TubePluggingDecember1996}}

Revision as of 16:52, 7 July 2018

Proposed Tech Specs Re Safety Limits & Limiting Safety Sys Settings
ML17229A183
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 12/20/1996
From:
FLORIDA POWER & LIGHT CO.
To:
Shared Package
ML17229A182 List:
References
NUDOCS 9612270074
Download: ML17229A183 (3)


Text

L-96-333 Attachment 3 ATTACHMENT 3 ST.LUCIE UNIT 1 MARKED-UP TECHNICAL SPECIFICATION PAGE Page,2-1 9612270074 96i220 VDR aDOCX OS000SS5 P PDR

~~I I 2.0 SAFETY LIMITS ANO LIMITING SAFETY SYSTEN SETTINGS 2.1 SAFETY LIMITS REACTOR CORE~gL.f I p$gE g as&2.1.1 The combfnatfon of THERMAL PNER, pressurfzer pressure, and maxf-axan cold leg coolant temperature shall not exceed the lfmfts shown on Ff gure 2.1-1.APPLICABILITY:

MODES 1 and 2.ACTION: Whenever the point defined by the combfnatfon of maxfnam cold leg tetnper-ature and THERMAL POWER has exceeded the appropriate pressurizer pressure line, be in HOT STANDBY within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.REACTOR COOLANT SYSTEM PRESSURE 2.1.2 The Reactor Coolant System pressure shall not exceed 2750 psfa.APPLICABILITY:

MODES 1, 2, 3, 4 and 5.ACTION: MODES 1 and 2 Whenever the Reactor Coolant System pressure has exceeded 2750 psfa, be in HOT STANDBY with the Reactor Coolant System pressure within its limit within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.MODES 3, 4 and 5 Whenever the Reactor Coolant System pressure has exceeded 2750 psfa, reduce the Reactor Coolant System pressure to within its limit within 5 minutes.Qt" L]=lE Amendment No.ST.LUCIE-UNIT 1 2-1 L-96-333 Enclosure ENCLOSURE Siemens Power Corporation-Nuclear Division Report EMF-96-176, Revision 1 St.Lucie Unit 1 Small Break LOCA Analysis with 30%Steam Generator Tube Plugging December 1996