Proposed Tech Specs,Extending Applicability of Current RCS Pressure/Temp Limits & Maximum Allowed RCS Heatup & Cooldown Rates to 23.6 Effective Full Power Yrs of Operation
ML17228B147
Person / Time
Site: Saint Lucie 
Issue date: 05/17/1995
From:
FLORIDA POWER & LIGHT CO.
To:
Shared Package
ML17228B146 List:
References
NUDOCS 9505240234
Download: ML17228B147 (16)


Text

St. Lucie Unit 1 Docket No. 50-335 Proposed License Amendment RCS Pressure Tem erature Limits ATTACHMENT 4 ST ~ LUCIE UNZT 1 MARKED-UP TECHNICAL SPECIFICATION PAGES Page 3/4 1-8 Insert A

Page 3/4 1-9a Page 3/4 1-12 Insert B

Page 3/4 4-23a Page 3/4 4-23b Page 3/4 4-23c L

9505240234 9505l7 PDR ADOCK 05000335,

..P PDR

REACTIVITY CONTROL SYSTEMS 3/4.1.2 BORATION SYSTEMS FLOW PATHS -

SHUTDOWN LIMITING CONDITION FOR OPERATION 3.1.2.1 As a minimum, one of the following boron injection flow paths shall be OpERABLE and capable of being powered from an OPERABLE emergency power source.

a.

A flow path from the'oric acid makeup tank via either a

boric acid pump or a gravity feed connection and any charging pump to the Reactor Coolant System if only the boric acid makeup tank in Specification 3.1.2.7a is OPERABLE, or b.

The flow path from the refueling water tank via either a

charging pump or a high pressure safety injection pump*

to the Reactor Coolant System if only the refueling water tank in Specification 3.1.2.7b is OPERABLE.

APPLICABILITY:

MODES 5 and 6.

ACTION:

With none of the above flow paths OPERABLE, suspend all operations involving CORE ALTERATIONS or positive reactivity changes until at least one injection path is restored to OPERABLE status.

SURVEILLANCE RE UIREMENTS 4.1.2.1 At least one of the above required flow paths shall be demonstrated OPERABLE:

a ~

At least once per 31 days by ver ifying that each valve (manual, power operated or automatic) in the flow path that is not-.

locked, sealed, or otherwise secured in position, is in its correct position.

<<The flow path from the RWT to the RCS via a single HPSI pump shall only be established if:

(a) the RCS pressure boundar does not exist, or (b) no char in um s are o erable.

h~g-pumps bl A-th 14~

e era&~PS+-header-she+}-be-veH+md-cased-and-have-t4

'w~moved.

Hi h Pressure Header Auxiliar Header ggglP,c6.

usLOA gggget" A g~ os~<

erne HCV-3616 HCV-3626 HCV-3636 HCV-3646 ST.

LUGIE - UNIT 1

3/4 1-8 HCV-3617 HCV-3627 HCV-3637 HCV-3647 Amendment No. SP.HT.HH.

9$ >788.~

V ew A

e+-

e' I

~ b%

OH 1

r Q~>~'jtQA i

(.

f41'5 w ys ~~~g

+'~404'J v~

St. Lucie Unit 1 Docket No. 50-335 Proposed License Amendment RCS Pressure Tem erature Limits IN ERT-A In the latter case:

1) all charging pumps shall be disabled; 2) heatup and cooldown rates shall be limited in accordance with Figure 3.1-lb, and 3) At RCS temperatures below 115'F, any two of the following valves in the operable HPSI header shall be verified closed and have their power removed:

100

$0 w

50 CC io Heatup 20 000 120 110 Coo@own 220 To - INDCATKDREACTOR COOLANT TEMPERATURE, f FlQURK 3.1 ~ 1b NAXSNMALLOWAbLEHEATQP Al COOLDOWN RATES, SNQLE IN 0 RATION

('Z3,(o EFPY)

ST.

LUGIE - UNIT 1

3/4 1-9a Amendment no.

SJ, ~

C r>'7

REACTIVITY CONTROL SYSTEMS CHARGING PUMPS -

SHUTOOWN LIMITING CONOITION FOR OPERATION 3.1.2.3 At least one charging pump or high pressure safety injection pump* in the boron injection flow path required OPERABLE pursuant to Specification 3.1.2el shall be OPERABLE and capable of being powered from an OPERABLE emergency bus.

APPLICABILITY:

MODES 5 and 6.

ACTION:

With no charging pump or high pressure safety injection pump* OPERABLE, suspend all operations involving CORE ALTERATIONS or positive reactivity changes until at least one of the required pumps is restored to OPERABLE status.

SURVEILLANCE RE UIREMENTS 4.1.2.3 At least one of the above required pumps shall be demonstrated OPERABLE by verifying the charging pump develops a flow rate of greater than or equal to 40 gpm or the high pressure safety injection pump develops a total head of greater than or equal to 2571 ft. when tested pursuant to Specification 4.0.5.

  • The flow path from the RWT to the RCS via a single HPSI pump shall be established only if:

(a) the RCS ressure boundary does not exist, or (b) no char in um s are o erable.

arg+ng-pum e

n eatup-and-coo%down-vates-shal-1 be-l-iaN+d-i~ccor4anc~h Rg. 8".Hb Af-PCS-h 0

b 1 ~lMF ~

QMh~ll peva~PSI-header-shaR-be-ver i-5i~-&esed-and-have-their-power-removed.

Hi h Pressure Header HCV-3616 HCV-3626 HCV-3636 HCV-3646 Auxi1 iar Header HCV-3617 HCV-3627 HCV-3637 HCV-3647 ST.

LUCIE - UNIT I 3/4 1-12 Amendment No. dd, di, ltd, 154, ~

ll H I'4\\

Os ~

IEMlI

~syq

~,

. r, AH4J

<V.N~c,Cgg

~ W.fc Aa Lqwofic 3~0~

0

St. Lucie Unit 1 Docket No. 50-335 Proposed License Amendment RCS Pressure Tem erature Limits ERT-B In the latter case:

1) all charging pumps shall be disabled; 2) heatup and cooldown rates shall be limited in accordance with Figure 3.1-lb, and
3) At RCS temperatures below 115'F, any two of the following valves in the operable HPSI header shall be verified closed and have their power removed:

L 4

FIGURE 3.i-2a 5T. LUCIK UNIT 1 PIT LIMITS.

KFPY HEATUP ANO CORK CRITICAL 2500 ISOTHERMAL TO ~>M 2000 1 500 g

1004 LOWEST SERVICE TEMPERATURE 1NPF CCNK CRITICAL ISO~ANAL 500

. IL SOLTUP~.~

, ALLOWAOLE&ATUP RATKS RATE.~Fit% ~ LN4T, ~F

$0 AT Au.

TEMPERATURES 344 k,.i

~04 TC - INOICATKO RCS TKMPKRATURK, F ST.

LUCIE - UNIT 1

3/4 4-23a Amendment No. 27,gS,HE, ~g'

.Ir

~~~, a~~

RGLHK ~ 4-Rh ST. LUCK LNT 1 P/T LMNTS, ESPY COOLDOWN Al WWVCK TEST 2500 2000 NSKAVICE HYOAOSTATIC TEST LOWEST SEAVCR T~KAATURK 1OPI'/M TO O~RQAl oooo OTl%IRNAL 500 0

'P/tN

~l~

4tVflNI SCPtlNl TIVE'll%

'I00eP/M TC

+4ICATEQ ACS TENPKllATMAK, F ST.

LUCIE - UNIT 1

3/4 4-23b Amendment No. 17,gg,g7,

~<

Pp

FIGURE 3A.3 ST. LUC!KUNIT 1, KFPY MAXIMUMALLOWAbLKCOOLDOWN RATES 80 a'

50 CC X

RATE, 4flHR 20 30 iO 50 75 100 TEMf. LIMIT,4f 4125 125 li5 145 155 1tw.1e5 165.195

)195 Te

~ INDCATjD REACTOR COOLANTTEMflRATURR, f NOTE: A MAXIMUMCOOLOOWN RATKOf 100 f/HR IS ALLOWEDAT ANY TKMfKRATURKASOVK 19$ f ST.

LUCIE - UNIT 1

3/4 4-23c Amendment No. 77.RS.HT.P~