L-96-184, Revised Tech Specs Re Core Alteration Definition

From kanterella
(Redirected from ML17228B564)
Jump to navigation Jump to search
Revised Tech Specs Re Core Alteration Definition
ML17228B564
Person / Time
Site: Saint Lucie  NextEra Energy icon.png
Issue date: 07/15/1996
From:
FLORIDA POWER & LIGHT CO.
To:
Shared Package
ML17228B563 List:
References
L-96-184, NUDOCS 9607230015
Download: ML17228B564 (3)


Text

St. Lucie Unit 1 and Unit 2 Docket Nos. 50-335 and 50-389 Proposed License Amendments-Revised L-96-184 ATTACHMENT1 REVISED TS CHANGE 96072300i5 960715 PDR ADQCK 05000335 P

PDR

i St. Lucie Unit 1 and Unit 2 Docket Nos. 50-335 and 50-389 Proposed License Amendments-Revised L-96-184 Mark-u f he definition for core al era ion as ori inall submitted o he NR 1.9 CORE ALTERATIONshall be the movement or manipulation of any fuel, sources, reactivity control components,

, or other components affecting reactivity within the reactor vessel with the vessel head removed and fuel in the vessel.

Exceptions to the above include shared@4 fingered) control. element assemblies (CEA) withdrawn into the upp'er:gu1Fii~8t~ru'C'tii"'e (UGSi or evolutions performed with the UGS in place such as CEA latching/unlatching or verification of latching/unlatching which do not constitute a CORE ALTERATION.

Suspension of CORE ALTERATIONSshall not preclude completion of movement of a component to a safe position.

v's d d fni ion of core al era ion as re ues ed b the NRC.

1.9 CORE ALTERATIONshall be the movement or manipulation of any fuel, sources, reactivity control components, or other components affecting reactivity. within the reactor vessel with the vessel head removed and fuel in the vessel.

Exceptions to the above include shared (4 fingered) control element assemblies (CEA) withdrawn into the upper guide structure (UGS) or evolutions performed with the UGS in place such as CEA latching/unlatching or verification of latching/unlatching which do not constitute a CORE ALTERATION, Suspension of CORE ALTERATIONS shall not preclude completion of movement of a component to a safe position.

~B1 f h

The revised definition for core alteration proposed by FPL (L-95-140) classified the lifting or lowering of the upper guide structure as a core alteration based on wording in the existing facilityTechnical Specifications.

However, the Standard Technical Specifications for Combustion Engineering Plants (STS), NUREG 1432-Revision 1, excludes the UGS from the core alteration generic definition. Although the proposed definition could be approved, the NRC requested FPL to consider eliminating the additional limitation to be more consistent with the STS.

The exceptions allowed for 4 fingered CEAs withdrawn into the UGS and the latching/unlatching or verification of CEA latching/unlatching are acceptable deviations allowed by the generic STS to account for plant specific design.

These differences were incorporated into the definition to resolve site specific concerns raised by individual NRC inspectors during previous refueling outages and clarified through correspondence with the NRC.

0:

t 4

~