FPLST.LUCIEPLANTCHEMISTRYOPERATINGPROCEDURESAFETYRELATEDProcedureNo.COP-06.06CurrentRev.No.EffectiveDate:07/13/99Title:GUIDELINESFORCOLLECTINGPOSTACCIDENTSAMPLESResponsibleDepartment:RevisionSummaryCHEMISTRYRevision1-AddedlimitinStep3.1tobemorespecificonhighradiationsamplesandchangedstatementin3.1byremoving"rates"soinformationsays"dosetopersonnelwillnotexceedNRClimits."(J.H.Burgess,06/17/99)PROCEDURE"PRODUCTIONRevisionFRGReviewDate10/13/98RevisionFRGReviewDate06/17/99ApprovedByR.G.WestPlantGeneralManagerApprovedByR.G.WestPlantGeneralManagerN/ADesignatedApproverApprovalDate10/13/98ApprovalDate06/17/99SOPSDATEDOCTPROCEDUREDOCNCOP-06.06SYSCOMPCOMPLETEDITM19'P07300i52990726PDRADQCK05000335FPDR>t
'$k REVISIONNO.:1PROCEDURENO.:COP-06.06PROCEDURETITLEGUIDELINESFORCOLLECTINGPOSTACCIDENTSAMPLESST.LUCIEPLANTTABLEOFCONTENTSPAGE:2of13SECTIONPAGE1e0PURPOSE~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
32.0REFERENCES
~~~~~~~33.0PREREQUISITES~.................~~.~..~...~.........34.0PRECAUTIONS/LIMITATIONS.............................35,0RECORDSREQUIRED.............~.................~..46.0INSTRUCTIONS.....,..........~.....~~....'.~........~56.1ConsiderationsBasedontheAccidentSituation...~..~~~5APPENDIXAPPENDIXAGUIDELINESFORAREASOFCONCERNFORLONGTERMPOSTACCIDENTSURVEILLANCE............
REVISIONNO.:1PROCEDURENO.:COP-06.061.0PURPOSEPROCEDURETITLEGUIDELINESFORCOLLECTINGPOSTACCIDENTSAMPLESST.LUCIEPLANTPAGE:3of131.1ToprovideguidelinesfortheOSCChemistrySupervisortouseforsamplecollectionandoperationalconcernsintheOSC.1.2Toprovideguidelinesthatidentifypossibleareasofconcernsforalongtermsurveillanceprogramfollowingaplantincident.
2.0REFERENCES
2.1TechnicalSpecifications,Section3.4.82.2EPIP-05,ActivationandOperationoftheOperationalSupportCenter2.3ADM-17.09,Invoking10CFR50.54(X)3.0PREREQUISITES3.1PostAccidentSamplingSystemmustbeoperationalwhencollectinghighradiationsamples(>10r/hrcontact).ThenormalsamplingsystemmaybeusedtocollectpostaccidentsamplesonlyifdosetopersonnelwillNOTexceedNRClimits./R13.2CountingRoomdetectorsmustbeoperationalforsampleisotopicanalysis.Itmaybenecessarytomovethecountingequipmenttoanareasuitableforoperation(lowbackground).3.3AllChemistrypersonnelthatworkfromtheOSCforsamplingduringreentrytotheplantshallberespiratorandSCBAqualified.4.0PRECAUTIONS/LIMITATIONS4.1NOsampleswillbetakenforoutsideagencieswithouttheconcurrenceofboththeEmergencyCoordinatorandtheChemistrySupervisor.4.2ThenumberofsamplescollectedmayvaryfromthosedescribedinthisprocedurebasedonmanpowersupportfromtheOSC.4.3HighRadiationAreaswillbepresentwhenobtainingliquidorgaseoussamples.Radiationsurveyinstrumentsshouldbemonitoredfrequentlywhilepurginganddrawingsamples.
REVISIONNO.:1PROCEDURENO.:COP-06.06PROCEDURETITLE:GUIDELINESFORCOLLECTINGPOSTACCIDENTSAMPLESST.LUCIEPLANTPAGE:4of134.0PRECAUTIONS/LIMITATIONS(continued)4.4HealthPhysicsshallbriefallteamsmakingre-entryintotheplantfromtheOSC.Doseextensionsmaybenecessarypriortoentry.4.5AllsamplesshallbelabeledwithproperidentificationandresultsenteredintotheLIMSsystem.4.6IfaContainmentIsolationSignal(CIS)hasactuated,ThensamplevalvesmustberesetandCISoverrideprovidedinordertoobtainsampleflowfromtheRCSorcontainment.4.7ThecontainmentradiationmonitorssamplelinewillbeisolatedfollowingaCIS.ThesamplepumponthemonitorshouldbestoppedfromtheControlRoom.4.8SteamGeneratorBlowdownsamplevalveswillcloseafteraCISactuation.ThesamplevalvesmaybereopenedifnecessaryandsamplescollectedinsidetheRABattheblowdownsamplepaneltopreventthespreadofcontaminationtotheColdLab.4.9TheflowpathofLPSIshouldbeverifiedwiththeControlRoompriortosamplingshutdowncooling.4.10Itmaybenecessarytoleavetheareawhileasampleispurginginordertoreduceexposure.4.11ContainmentairsamplesmaybecollectedfromthePostLOCAHydrogenanalyzersifaCIShasisolatedtheradiationmonitor.TheUnit2PASSsystemisalsocapableofdrawingacontainmentairsample.4.12TheSteamGeneratorBlowdownBuildingshouldbekeptuncontaminatedifpossibleafteratuberupturebyleavingblowdownisolatedorbyblowingdowntothedischargecanalifreleasepermitlimits(ECL)areNOTexceeded.5.0RECORDSREQUIRED5.1NormalentriesontheChemistryLIMSsystem.ResultsshallbemaintainedintheplantfilesinaccordancewithQI-17-PSL-1.
REVISIONNo.:PROCEDURENo.:COP-06.06PROCEDURETITLE:GUIDELINESFORCOLLECTINGPOSTACCIDENTSAMPLESST.LUCIEPLANTPAGE:5of136.0INSTRUCTIONS6.1Thefollowingconsiderationsshouldbemadebasedontheaccidentsituation:REFERtoEPIP-05,ActivationandOperationoftheOperationalSupportCenter,forchecklistitemstoestablishtheOSCasoperational~2.ESTABLISHtheplantstatusandASSESStheoperabilityoftheprocessmonitors.3.CHECKALLofthefollowingeffluentflowpathstoascertainifanabnormalreleaseisinprogress:A.PlantVentB.FuelHandlingBuildingC.ECCSVentD.AirEjectorExhaustE.SteamLineF.S/GBlowdownBuildingVentG.S/GLiquidBlowdownH.Containment3.IfaCIShasoccurred,ThenSTOPthesamplepumpsonthecontainmentprocessmonitor.4.TheTSCChemistrySupervisorshoulddetermineifitisnecessarytoestablisharemotecountinglaboranalysislab.5.DETERMINEwhichlabcanbeusedforsampleanalysis.6.MONITORfornoblegasconcentrationandradiationlevelinanylabareathatisinuse.HealthPhysicscanprovidefriskersorairsamplingequipment.
REVISIONNO.:PROCEDURENO.:COP-06.06PROCEDURETITLEGUIDELINESFORCOLLECTINGPOSTACCIDENTSAMPLESST.LUCIEPLANTPAGE:6of136.0INSTRUCTIONS(continued)6.1Thefollowingconsiderationsshouldbemadebasedontheaccidentsituation:(continued)7.OBTAINareactorcoolantsampleifnecessary.A.PERFORMaboronanalysisonthereactorcoolantsample.B.PERFORMagammaspectrumanalysisonthereactorcoolantsample.Primaryconcernsarethelevelsoffissionproductiodinesandcesiums.C.NOTIFYtheTSCChemistrySupervisorofthereactorcoolantgammaspectrumanalysisresults.8.TheTSCChemistrySupervisormaywaivertheTech.Spec.requirementforsamplingoftheRCSwhentheRCSDEQisgreaterthan1.0pCI/mlduringaccidentconditionstolimitpersonnelexposureiftherequirementsofADM-17.09,Invoking10CFR50.54(X)aremet.9.IfthePlantVenteffluentmonitorisreadingupscale,OBTAINaPlantVenteffluentsampleforparticulate,iodineandgas.(SAMPLEtheFuelHandlingBuildingeffluentifthereisafuelhandlingaccident).10.Ifthesteamlinemonitor,airejectormonitororsteamgeneratorblowdownmonitorsarereadingupscale,thesteamgeneratorsshouldbeSAMPLEDforprimarytosecondaryleakage.11~Whenconditionspermit,CONSIDERsamplingthefollowingtanksforgrossactivity:ChemicalDrainTankEquipmentDrainTankAeratedWasteStorageTankSpentFuelPool,ifthereisafuelhandlingaccidentMainCondenserHotwell,ifprimarytosecondaryleakhasoccurred REVISIONNO.:PROCEDURENO.:COP-06.06PROCEDURETITLE:GUIDELINESFORCOLLECTINGPOSTACCIDENTSAMPLESST.LUCIEPLANTPAGE:7of136.0INSTRUCTIONS(continued)6.1Thefollowingconsiderationsshouldbemadebasedontheaccidentsituation:(continued)12.TheComponentCoolingWaterSystemshouldbeSAMPLEDforisotopicanalysisiftheprocessmonitorsshowanincreaseincountrate.13.AVOIDgettingsodiummolybdate(CCW)inthewasteionexchangerstopreventdepletion.14.PostLOCAhydrogenanalyzerscanbegrabsampledifnecessaryforcontainmenthydrogenanalysis.15.REFERtoAppendixAforareasofconcernforlongtermPostAccidentsurveillance.ENDOFSECTION6.1 REVISIONNo.:1PROCEDURENo.:COP-06.06PROCEDURETITLE:GUIDELINESFORCOLLECTINGPOSTACCIDENTSAMPLESST.LUCIEPLANTPAGE:8of13APPENDIXAGUIDELINESFORAREASOFCONCERNFORLONGTERMPOSTACCIDENTSURVEILLANCE(Page1of6)TheTSCChemistrySupervisorwilldeterminewhattestsandschedulingfrequencywillapplytoeachareaofconcern.Theareasofconcernareasfollows:~ContainmentBuilding~ReactorCoolant(onShutdownCooling)~ReactorAuxiliaryBuildingCVCSLetdownSystem~GaseousWasteSystem~LiquidWasteSystems~SecondarySystems1.ContainmentBuildingMajorconcernsare:A.Estimatingtheinitialinventoryofwaterinjected,totalinventoryinthecoreandcavitysumpincludingthechemicalandnuclidecomposition.B.Trackingadditionstothecontainmentwatervolume:C.Trackingchangesinthenuclidemixtureofthewater.D.Trackingatmosphericcompositionforpercentgasesandnuclideconcentrations.E.ContainmentSump,QuenchTank,ReactorDrainTankcomposition.F.ContainmentpurgeorHydrogenpurgethatcouldreleasehotgases.G.Containmentpenetrationsthatcouldallowwateroutorintocontainment.
REVISIONNO.:PROCEDURENO.:COP-06.06PROCEDURETITLE:GUIDELINESFORCOLLECTINGPOSTACCIDENTSAMPLESST.LUCIEPLANTPAGE:9of13APPENDIXAGUIDELINESFORAREASOFCONCERNFORLONGTERMPOSTACCIDENTSURVEILLANCE(Page2of6)ContainmentBuilding(continued)ActionstoConsider:A.REVIEWthedatafromtheinitialpostaccidentsamplesfortanklevels.COMPAREthisdatatothelogspriortotheincident.B.CALCULATEprobablecontainmentsumpvolumeandboronconcentration.C.COMPAREcalculateddatatoactualgrabsampleresults.D.CHANGESinvalvelineupsonlinesthatexitthecontainmentbuildingmustbereviewedfordoseconcerns.2.ReactorCoolant(onShutdownCooling)MajorConcerns:A.Spreadofcontaminationtoassociatedsystems.-B.Anysourceofdilutionwaterintoshutdowncooling.C.LeaksintheshutdowncoolingheatexchangertoComponentCoolingWatersystem.D.Anadequatemakeupsupplytoshutdowncooling.E.Contentsofthesafeguardsumps.F.RABliquidradwastesystemscontaininghighlycontaminatedwater.
C REVISIONNO.:PROCEDURENO.:COP-06.06PROCEDURETITLEGUIDELINESFORCOLLECTINGPOSTACCIDENTSAMPLESST.LUCIEPLANTPAGE:10of13APPENDIXAGUIDELINESFORAREASOFCONCERNFORLONGTERMPOSTACCIDENTSURVEILLANCE(Page3of6)2.ReactorCoolant(onShutdownCooling)(continued)ActionstoConsider:A.VERIFYthereisNOborondilutiontotheshutdowncoolingsystembygrabsamplingSDCandthemakeupsupply.B.VERIFYoperationoftheComponentCoolingWaterprocessmonitorsforSDCleakdetection.USEgrabsamplestomonitortheCCWactivity,ifnecessary.3.ReactorAuxiliaryBuildingCVCSLetdownSystemMajorconcernsare:A.WaterwithhighlevelsofcontaminationmaybeintheRAB.B.TheVCTmayhaveahydrogencovergaswithhighnoblegasactivity.C.WaterintheletdownsystemmaybeatalowerboronconcentrationthantheSDCsystemandactasasourceofdilutionwater.D.TheCVCSionexchangersmayNOTbeboratedtothesameconcentrationastheSDCsystemandwillremoveboronuntilanequilibriumisreached.E.ThegaseouswastesystemmaycontainhighgasactivityfromtankventsorVCTpurges.ActionstoConsider:A.DETERMINEtheisotopiccontentoftheVCTgasbygrabsampling.B.CVCSionexchangersmaycontaindoserateshigherthanshieldingdesign.
t REVISIONNO.:PROCEDURENO.:COP-06.06PROCEDURETITLE:GUIDELINESFORCOLLECTINGPOSTACCIDENTSAMPLESST.LUCIEPLANTPAGE:11of13APPENDIXAGUIDELINESFORAREASOFCONCERNFORLONGTERMPOSTACCIDENTSURVEILLANCE(Page4of6)3.ReactorAuxiliaryBuildingCVCSLetdownSystem(continued)ActionstoConsider:(continued)C.MONITORthePlantVentprocessmonitorforabnormalgaseousreleases.D.MONITORanywatermovementsthroughtheRABforhighactivity.E.Holduptanksshouldbesampledforhighactivity.ThepreconcentratorionexchangercanbeusedforcleanupofHUTSpriortowasteprocessing.4.GaseousWasteSystemMajorconcernsare:A.'Gasdecaytanksmaybefilledfasterthanusual~Theremaybelesstimeavailablefordecayofhighactivity.B.Oxygenmaybeintroducedintothegasdecaytanksfromimpropervalvelineups.Tanksshouldbemonitoredforexplosivegasmixtures.C.Nitrogensupplyalignedtonon-essentialequipmentmayfillGDTs.D.ImpropervalvelineupsmayreleasehighactivitygasorexplosivegasmixturesintotheRAB.Actionstoconsider:A.TheGasAnalyzershouldNOTbealignedtoahighlyradioactiveGDT.B.TheGasAnalyzershouldbeoperatedontheGasSurgeHeader.C.TheGDTpressuresshouldbemonitoredclosely.D.VERIFYthereareNOexplosivegasmixturesformedbyroutinegrabsampling.
REVISIONNO.:1PROCEDURENO.:COP-06.06PROCEDURETITLE:GUIDELINESFORCOLLECTINGPOSTACCIDENTSAMPLESST.LUCIEPLANTPAGE:12of13APPENDIXAGUIDELINESFORAREASOFCONCERNFORLONGTERMPOSTACCIDENTSURVEILLANCE(Page5of6)5.LiquidWasteSystemsMajorconcernsare:A.CONTROLthespreadofhighlycontaminatedwaterintheRAB.B.MONITORtanklevelsandsumplevelsthathaveautostartingpumpstocontrolthespreadofcontamination.C.MONITORtanklevelstoavoidoverflowofthesystem.D.Chemicalcontaminants(i.e.,sodiumhydroxide,hydrazineortrisodiumphosphate)willrapidlydepletetheionexchangers.E.Avoiddrainingsectionsofpipingthatcontainhighlyradioactivewater.Actionstoconsider:A.ISOLATE,ifpossible,anysourceofhighlyradioactivewaterintheRABwastesystem.B.ESTABLISHcontrolsofRABwatermovements.C.MONITORtanklevelsonamorefrequentbasis.D.VERIFYthewasteionexchangersareperformingpropercleanupofwastewater.E.REQUESTthatcirculatingwaterpumpsbeleftinoperationforadequatedilutionflowforliquidreleases.F.CONSIDERhavingtoprocessverylargevolumesofwastewater(fromS/Gtuberupture).
REVISIONNO.:1PROCEDURENO.:COP-06.06PROCEDURETITLE:GUIDELINESFORCOLLECTINGPOSTACCIDENTSAMPLESST.LUCIEPLANTPAGE:13of13APPENDIXAGUIDELINESFORAREASOFCONCERNFORLONGTERMPOSTACCIDENTSURVEILLANCE(Page6of6)6.SecondarySystemsMajorconcernsare:A.Containingthespreadofcontamination.B.Treatmentoflargevolumesofcontaminatedwater.C.Restricteduseofchemicalsinthesystems.D.Blowdownsystemisadirectreleasepathtothedischargecanal.E.Controlofcontaminatedwaterinthecondenserhotwell.Actionstoconsider:A.MONITORthepondsbygrabsamplingforcontamination.B.VacuumdragshouldbesecuredafteraS/GtuberupturetoavoidcontaminationoftheotherUnit.,C.Theblowdownbuildingresintrainsmaybecomecontaminatedandrequireproperhandlingforresindischarge.D.RESTRICTtheuseofamerzineandhydrazineonthesecondarysidetoavoiddepletionoftheionexchangersusedforwasteprocessingofcontaminatedwater.ENDOFAPPENDIXA K4 Title:FPLST.LUCIEPLANTHEALTHPHYSICSPROCEDURESAFETYRELATEDProcedureNo.HP-201CurrentRevisionNo.EffectiveDate06/15/01EMERGENCYPERSONNELCONTROLgResponsibleDepartment:HEALTHPHYSICS-8-PSLREVISIONSUMMARY:PROCFDUgp~DUCTfoxRevision9-THISPROCEDUREHASBEENCOMPLETELYREWRITTE.eexposureguidelinebasis,addedTMIshieldingstudyandmadeeditorialandadministrativechanges.(J.R.Walker,06/11/01)Revision0Revision9FRGReviewDate02/01/82FRGReviewDate06/07/01ApprovedByJ.H.Barrow(for)PlantGeneralManagerApprovedByR.G.WestPlantGeneralManagerN/ADesignatedApproverN/ADesignatedApprover(MinorCorrection)ApprovalDate02/02/82ApprovalDate06/11/01SOPSDATEDOCTPRQGEDUREDQCNHP-201SYSCQMcoMPLETEDITM9 NIIHmv REVISIONNO.:PROCEDURENo.:HP-201PROCEDURETITLE:EMERGENCYPERSONNELEXPOSURECONTROLST.LUCIEPLANTPAGE:2of32SECTIONTABLEOFCONTENTSPAGE1.0PURPOSE
2.0REFERENCES
3.0RELATEDSYSTEMSTATUS4.0PRECAUTIONS/LIMITATIONS5.0RECORDS6.0INSTRUCTIONS~~~~~~~e46.16.26.3Guidanceforcontrollingexposuresunderemergencyconditionsisprovidedin:~.~.~5InitialRe-EntryTeam.6SubsequentEntries~~~7ATTACHMENTSATTACHMENT1EXPOSURELIMITSFOREMERGENCYRESPONSEPERSONNELATTACHMENT2FPLTMIPLANTSHIELDINGSTUDY-UNIT1.~~~~~~~e8ATTACHMENT3FPLTMIPLANTSHIELDINGSTUDY-UNIT2.~~..~.~..~.17 REVISIONNO.:PROCEDURENo.:HP-201PROCEDURETITLE:EMERGENCYPERSONNELEXPOSURECONTROLST.LUCIEPLANTPAGE:3of321.0PURPOSE1~1Thisprocedureprovidesthemethodstobefollowedtocontrolradiologicalexposureofpersonnelduringemergencies.
2.0REFERENCES
NOTEOneormoreofthefollowingsymbolsmaybeusedinthisprocedure:IndicatesaRegulatorycommitmentmadebyTechnicalSpecifications,ConditionofLicense,Audit,LER,Bulletin,OperatingExperience,etc.andshallNOTberevisedwithoutFacilityReviewGroupreviewandPlantGeneralManagerapproval.f[Indicatesamanagementdirective,vendorrecommendation,plantpracticeorothernon-regulatorycommitmentthatshouldNOTberevisedwithoutconsultationwiththeplantstaff.'PIndicatesastethatreuiresasinoffonanattachmen.2.110CFR20,StandardsforProtectionAgainstRadiation.2.2St.LuciePlantRadiologicalEmergencyPlan(E-Plan)2.3E-PlanImplementingProcedures(EPIP00-13)2.4HP-2,"FPLHealthPhysicsManual."2.5NuclearEnergyPolicyonExposureLimitsforEmergencyResponsePersonnel,RevisiontoPolicyStatement,Ltr.No.JNO-HP-94-056,October26,1994.2.6HPP-30,"PersonnelMonitoring."2.7HP-33,"PocketDosimeters."2.8HPP-60,"RespiratoryProtectionManual."2.9HPP-61,"UseofRespiratoryProtectiveEquipment."2.10HPP-63,"DAC-HourAssessment."2.11HP-203,"PersonnelAccessControlDuringEmergencies."2.12EPA-400-R-92-001,ManualofProtectiveActionGuidesandProtectiveActionsforNuclearIncidents.2.13FPLTMIPlantShieldingStudy REVISIONNO.:PROCEDURENO.:HP-201PROCEDURETITLE:EMERGENCYPERSONNELEXPOSURECONTROLST.LUCIEPLANTPAGE:4of323.0RELATEDSYSTEMSTATUSNONE4.0PRECAUTIONS/LIMITATIONS4.1AllpersonnelexposureswillbemaintainedAsLowAsReasonablyAchievable(ALARA).4.2WhenHealthPhysicsnormaloperatingproceduresandemergencyproceduresdiffer,theemergencyprocedurestakeprecedence.4.3Entriesintoradiationareasexceeding10R/hrshouldnotbemadewithoutECorTSCHPSauthorization.4.4Emergencyresponsepersonnelshouldhavetheirexposureslimitedtothefollowingdoses.5remdeepdoseequivalent(externalexposure)asmeasuredbyself-readingdosimeter,or2.50remtothethyroidfrominhalationofiodines.5.0RECORDS5.1Whencompleted,theformslistedbelowshallbemaintainedintheplantfilesinaccordancewithQI-17-PSL-1,"QualityAssuranceRecords."1.FormHP203.1,EvacuatedAreaRe-entryAuthorization.2.FormHP203.2,EmergencyAccessControlLogSheet.
REVISIONNO.:PROCEDURENO.:HP-201PROCEDURETITLE:EMERGENCYPERSONNELEXPOSURECONTROLST.LUCIEPLANTPAGE:5of326.0INSTRUCTIONS6.1Guidanceforcontrollingexposuresunderemergencyconditionsisprovidedin:1.Attachment1,ExposureLimitsforEmergencyResponsePersonnel.2.Attachment2,FPLTMIPlantShieldingStudy-Unit1.3.Attachment3,FPLTMIPlantShieldingStudy-Unit2.ENDOFSECTION6.1 REVISIONNO.:PROCEDURENO.:HP-201PROCEDURETITLE:EMERGENCYPERSONNELEXPOSURECONTROLST.LUCIEPLANTPAGE:6of326.2InitialRe-EntryTeamTheinitialRe-entryTeamshallconsistofatleasttwopersonsoneofwhomshallbeaHealthPhysicsTechnician(HPT).2.3.4.TheinitialRe-entryTeamshallusetheprotectivemeasuresandmonitoringequipmentasdirectedbytheTSCHPSasindicatedontheEvacuatedAreaRe-entryAuthorization,formHP203.1(seeHP-203,"PersonnelAccessControlDuringEmergencies").TheinitialRe-entryTeammembersshallcarrydosimetryequipmentasdirectedbytheTSCHPSasindicatedontheEvacuatedAreaRe-entryAuthorization,formHP203.1(seeHP-203).TheRe-entryTeamshallbeloggedinontheEmergencyAccessControlLogSheet,HP203.2(seeHP-203)priortoenteringtheevacuatedarea.TheTSCHPSandHPOSCSupervisorshallcollaborateonassignedinitialstay-timesbasedonavailabledoserateinformation.TheRe-entryTeamwillfrequentlychecktheirdosimetersandwithdrawtoasafeareabeforeexceedingtheassignedlimits.ENDOFSECTION6.2 REVISIONNO.:9PROCEDURENO.:HP-201PROCEDURETITLE:EMERGENCYPERSONNELEXPOSURECONTROLST.LUCIEPLANTPAGE:7of326.3SubsequentEntriesTheTSCHPSandHPOSC(HPSupervisorintheOperationalSupportCenter)shallanalyzethedataobtainedfromtheinitialentryandshallsetrequirementsforsubsequententriesbasedonthisdata.FormHP203.1(seeHP-203)shallbeusedforallentriesunlessotherwisedirectedbytheTSCHPS.2.3.AllsubsequententriesshallbemadewithhealthphysicscoverageuntiltheareasenteredaredeclaredopenforlimitedaccessbytheTSCHPS.Noareaspreviouslyunsurveyedshallbeenteredwithouthealthphysicscoverage.TheEvacuatedAreaRe-entryAuthorizationformHP203.1(seeHP-203)shouldbecompletedanddosesrecordedonanindividualbeforethatindividualisallowedtoentertheareaasecondtimetoensurehedoesnotexceedemergencyexposureguidelines.NOTETheattachments(2forUnit1and3forUnit2)containareadoseratesoftheReactorAuxiliaryBuildings(RABs)basedonaThreeMileIslandUnit2(TMI-2)typeaccident.Theseattachmentsshouldbereferredtopriortoentryintoanareawheredoseratesareunknown.ThedoseratesmaybeverifiedbAreaRadiationMonitorsARMs.ENDOFSECTION6.3 REVISIONNO.:PROCEDURENO.:HP-201PROCEDURETITLE:EMERGENCYPERSONNELEXPOSURECONTROLST.LUCIEPLANTPAGE:8of32ATTACHMENT1EXPOSURELIMITSFOREMERGENCYRESPONSEPERSONNEL(Page1of1)NOTE1.BothTotalDose(TEDE)andThyroidDose(CDE)shouldbeusedforpurposesofcontrollingexposure.2.Protectiveclothin,includinresirators,shouldbeusedwherearoriate.Forthefollowingmissions,theexposurelimitis':TotalDose<ITHYROID'TEDE)(CDE)Performanceofactionsthatwouldnotdirectlymitigatetheevent,minimizeescalation,orminimizeeffluentreleases.5REM50REMPerformanceofactionsthatmitigatetheescalationtotheevent,rescuepersonsfromanon-lifethreateningsituation,minimizeexposuresorminimizeeffluentreleases.10REM100REMPerformanceofactionsthatdecreasetheseverityoftheeventorterminatetheprocessescausingtheeventinanattempttocontroleffluentreleasestoavoidextensiveexposureoflargepopulations.25REM250REMshouldbeabovetheageof45.)(5)(5)(1)Exposurelimitstothelensoftheeyeare3timestheTotalDose(TEDE)valueslisted.(2)TotalDose(TEDE)isthetotalwholebodyexposurefrombothexternalandinternal(weighted)sources-TotalEffectiveDoseEquivalent.(3)ThyroidDose(CDE)commitmentfrominternalsources-CommittedDoseEquivalent.Thesamedoselimitsalsoapplytootherorgans(CDE),skin(ShallowDoseEquivalent)andextremities(ExtremityDoseEquivalent).(4)Volunteerswithfullawarenessofrisksinvolvedincludingnumericallevelsofdoseatwhichacuteeffectsofradiationwillbeincurredandnumericalestimatesoftheriskofdelayedeffects.(5)NoupperlimitforTotalDose(TEDE)and/orThyroidDose(CDE)exposurehasbeenestablishedbecauseitisnotpossibletoprejudgetherisksthatonepersonshouldbeallowedtotaketosavethelifeofanother.Also,nospecificlimitisgivenforthyroidexposuresinceintheextremecase,completethyroidlossmightbeanacceptablesacrificeforalifesaved.Thisshouldnotbenecessaryifrespiratorsand/orthyroidprotectionforrescuepersonnelareavailableastheresultofadequateplanning.ENDOFATTACHMENT1 LOCAI(~0<<Tv(<<I(Li~v.zUI4C)0Om0z0CmOT0zz0CHEMDRN.PUMPEOUSI,URN.PUMPIAAIAAT(4<<ALT(~ToalnTALIIWPTAICPWtsIII~III(0<<<<(.tfQvt(Lr4IIITT<<NIT<<V~WtsIINPInvt0I<<PL.AUWPLI<<<<NWtavi\1~1PIAJkLAV14AT~1<<,~IVIICI>>CllaIV<<AST(VPLTCIV~OVIsa<<4aATAVCMlanl<<00~VII~NII~la00Co<<4nrtiI~I~NIVta>>~Wt~PWtJN<<IJIIcacao(vs(LavaoavWANTal<<I~wr~Pert<<1st(CtlltTAAIIZONEUPPERLSIITDOSERATEIII01IVVVlcISMR/HRIS100MR/HR100~1000MIVHR10R/HR10100R/HR>>100R/HRLEOEND:ZONALDOSERATECLASSIFICATIONI<<P<<OPNco<<la<<vtat~PIATPI<<PIWAI~<<OL0VtO<<OLO.WTA<<II41(ACTO<<(NOAS~(~aa<<nvnOUIle<<0IWPAOII1(~iID<<1sanvvNNCTIO<<tVVPIICVOIOAALIVVPTAas~tvv>sI~I~II<<4rl<<C<<A14N4PWP<<Isle<<AAA4(<<I<<IA<<VI<<<<<<toat<<<<'W~aao<<asl(<<cc<<a(N<<4Vt~CIAYIACAI'OL4Vl'III~colo.aevavrt,rNCOLO.ICVIVstatist<<Tnt~vr(.t<<L,II<<PL~~I~IDla<<Al~(C<<C.~VVPl<<le<<ts<<NOW.twn~ooloAC<<taICollCIIIIAI0I~LTIIIUNIT1-0.5'AB1HOURAFTERACCIDENT'll-It(111(INTaas~0<<CACN>>OLO<<0tnnI~lan<<cJc<<Cl<<ls(rsatC~wravt(4<<((PiRPi20M447f~IIMCATIJ<<IIA10NON(10ll6)(O60OsCO~01<<AC<<co<<4IIIATITAVI~QIgzV)~I11OIZO+zzQ~CUICzCOI0ITlUIzQz0(60lCO0zXI0'TT0OOCmm gl0OmZ0(fllCD0Xz0g]00QliW0WOH00~hTHt.~HHtt01CHC/KL00tA0CVtWLNlMOOCHDAL3CC~HtCSQl/t/HHW00ace,ttt/i'll1lWClAIIANH00CHILFM7/ST0t0*gFT"(MMIjVl*ai+~~MfltWIIIIm-o~o$SeaaeuttCHOl.AOO1W4CG.C.ACONCIOWftIAWJ'H1WAr~00wNOHOAlL0000IKUIzU)~KQmoIXO+zmQzOl~lOCUIt:zCOQITlUzQz0(60zzm0U)mO0z000OmOm=IillII01IVVVIHISMA/HRIS-100MA/HR100~1000MR/HAI10A/HR10~100A/HA>ISOA/HALEOEND:ZONAI.DOSEAATECLASSIFICATIONZONEUFPERLLMIFDOSERATELESSIFVCTNOTUSFDVIABOVE0FEET.VBELOW0FEETUNIT119.5'AB1HOURAFTERACCIDENT(PiBPI20IW&RTfC)0CDM UMC)00Om0mOl0z0LOCITTOCPIT~<<CLT~T.~14'as11<<WetTaa'IIce<<<<I~IktalasIlsesstl~101I44Tsal~wertls<<wet+=::--:if)Los<<an<<seater~ve~~0CHEM.DRN.PUMPEOUIP.DRN.PUMPIAQI)Qessr~LOILrlaQIXJk~etaetaoasLLIWWT011wettOw+TacTe.lotWse~asTs1a<<I~T11I00~PLWK~00~4~4~010.~VisasCWV011Watswetle<<Tsl~CICL<<valesl1~Ctaraaa~11V1411tll<<rial~Lavaolrsaa.Wetat<<s~ZONALDOSERATECLASSIFICATIONUPPERLIMITDOSERATELEOENDIZONEIIIIIIIVVVI41$MAIHAIS~100MRIHR100~1000MRIHRI~10RIHR10~100AIHR>100RIHA<<Its.4<<a~lacT00LI4skew<<la<<twltlIaIasal~01ts<<111t~PWIPWtoI~~tsstevr<<Slot<<1~vetoIeoaolsL0OSOLOVtII~0~114<<0pl<<~v~TkaC~PWto~w~~.4cslt<<4<<letEHfil'OOvaotl>>olrlaT~aawceT01Iel,'1~esseaotcvec-sr~keel11~votes~~1>>Q4a.Cata.QQ~OltVPcacolctorpp.~oaovenrver~eta.wa,Qets~~elwaesceOLteopwpoOS<<0vtTSICw,-C)4-c'4L.1<<setta>>~Wtolets.~el14101kL~SIWC<<0.~vv~~wescd~11001CC1TlaTta~LTIII~40<<aleCoa<<1lST~~vvts~eI\~<<C(PiBP/20IWC-RTJUNIT1-05'AB10HOURSAFTERACCIDENT~wtlCarIlTkaslRAOLsORTTOR~01ala<<CC<<tlalsTCTwa~6)(DCDGDOelCOr50z0)~ITIOrzUQzmQzN~MUIz0)QmUzQz0000z0OILCD'000m0lTIIITI UIbC)0OmOmZ0lllLD0ZZ0gp!j!jHRKRCOIPITANIglg).CCTCWATtlIIIOKIOCM.t<<tttCffWCtt<<W/WtWONW<<IWWI%.I/NNCNT<<tN<<t<<Q~mq<<II<<CTAiX~It<<AT!I~AIll<<Ittot<<IO<<tedWIP%,0G*Qr/IIwTATU<<t(33SB~ACONC,N'ACONC5l"(MMTQVlg+3I>>g%Q~~i6ITCNNTCOWETIAW/tCNTPhLr'CIA~T<<WYATTa<<a@+I~NCI<<CQ,~VONCIINlOroJPiHPi20I-FD-Rl)KzM~XQmOIXOgzzQ~UIz0)0mUIzmQz0(80zCmO000OOLEOEND:ZONEI010IVVVIZONALDOSERATECLASSIFCATIONUPPERLIMITDOSERATE'1$MR/HR15100MR/HR1001000MA/HRI10R/HR10100A/HR>100R/HRLESSIFVOTNOTUSEDIVSELOWSFEETUNIT119.5'AB10HOURSAFTERACCIDENT LDCAICODVa<<Ir~LCTxUIbC)0Om0mz0lllEO0zz0CHEM.OAN.PUMPEOUSAORN.PUMPIAATAAI~oealflITOAAOCTat10~>VPTAAC~ve>~UI~IAIc4w'I0>aapw>C=.IL"I~cuarrevscttle~WtlLol~vac~taIa'Itf~I0III:::N>AIL~I~II4cv~4~IlaI>i<IA~100LAI<<41T~11~WMCDIICDIACCVD.~W>l~II~a<Vtae.~vep~pw~castsC014Tlat~Aaatla~CVCLDIVICLateOar4w.~vv>~tvv>ZONEUPPERUMITOUSEAATEI111IVVVI<1$MR/HR1$~100MA/HA1001000MA/HR110R/HA10~100A/HA>100A/HR1FOENOIZONAlOUSERATEClASSIFICATION~v>1laIoetaavart~NlTtWNI~0I<ILDV>~IACTOALIOCallitalePWNcraalao>vetVPIA>STTaaccrtwaIVM~ItcVot<<sat~vv~f111(~PWNI~I~I~fOO4taalasPvttcaaoaopw>~tcIl~t::4'asraVarasavae~>1111CVIOA>IIL,'1~UsealtsVCCI~IAalelsIIVCCtlt~Ae1I<10II~vaaleIlOA1atcaTart~acot<<,acrsrp>.t<<ewescrsrUCtrIVCTAVITTle>v>vUlavPLC~atVCLOOtI~CDCIErotoep4>1~VttM~aavoroltat~oselle>Nc4vclttaafoaTAMIIUNIT1-0.5'AB100HOURSAFTERACCIDENT<<~014AC<<~<<Loao>VVM~Ita~41<<aaoCCVOL1IATC~WtlIV>A~aa(PiHP/201WE&i7'tI-g<ae>aIoacf4IOL~><<VI~ACIICATT>1\IDAAOVOVITOTL6)(O(DQlO0)0410ACOCDAMWAT~tavtl5gzU)~XQmorzOg(0~h)UItZ0)0mazmQz0CO0ZZmX0O0z00AOCmIm DMCO0OmOmX0m010zR0tm,,-0-0NP.NP.COWlhhk~SSttCLNNI~ENLSCCW~ewatccc~RtRCCCClltttttttttaaSILT.PM'Ol>stecccaatcwIccctaatcNccttIPISNNWr"<WLSNSCO/N7/ST~CWNNCCPSLWCSSTRLSCMCCNCLtcRAlNttttLICNIIL~ateNcaNRNat4,ctcLIKac"CVCCtttccaatatccacaa08g63.B~ACONCKNSVQ-aCASSSOrNSVe>**~~~s0wccIAwrCNSII4.IIS~TNWLSISatSXCCCCChL~J0~NCNONLR0r00SCN/RCNLSStlfLSMSLOMCALO.~CttCN/SL.SMCNII.SI4.gI50zCO~XQmoIZOgZIl1Q~~h)0)C0ICzCOQm0mC)m00zzI0(0CO00Tl0OfllClmImLEOEND:ZONEInInIVVVIZONALDOSERATECLASSIFICATIONUPPERlSIITDOSERATEc1$MR/HR1$~'100MR/HR100~1000MR/HRI10R/HR10IOOR/HR>100R/HRlESSIFVCTNOTUSEDIVBELOW3FEETUNIT119.5'AB100HOURSAFTERACCIDENT LOCATEOOCTICWICLlP,UhDC)0AOCZ0IllCO0Z0CHEM.DAN.PUMPEOUTP.DRN.PUMP'IAPrlTw<<ll4WPTAac~WHIAI~Tat~VPL,SPK~LAC101LIOlacla~aa>>tsvpsAaaata0wall~STOAISEIAIC011~1IA\~~OVVTWA>>PWPIC"oa"~ovr.0as<<~WtLPI>>t10STOSTC.~4LP4afEIT<<IECTIOV~WPS~0IIwaal~COVTA>>VIVT~taattVVPII~~VVPTACC4twts~0~~IlwtWITT<<KCTO1PSVW~0~HwoaaaIIItooVIII~VA1ASIVE11A11VVC<<101<<IL'w~Aawaallvca.l~ILAICI011~LI~4~VPLv,~~-14101ALIlvtL~AET~COal~VVISLawow001,'CHIC~IAEVILl>>EI~1400Clv.~aa<<TAWIAlaŽ00CWV011~VVP~>>IVIAW>>IACC~ACL4<<lacILAW111Oaa.~IVPIPVVPLaratMtIA>>TAWSLEGEND:EONALDOSERATECLASSIFICATIONEONEUPPERLGlITDOSERATEIII1$IVVVI11$MR/HR1$~'100MA/HA100-1000MIVHRI~10R/HR10~100IVHR0100R/HRI~WvalTCCOAWIWIL4VPOSCL~VtTalII~Caaao<<0twpC3fl)aaa~AvQQOIOL~VtIMC~~cc>>0SCCATatIKCoao.aCIATUCOIIPWTITPITT~vta,tvL,c-PI~~AVICE~0<<0CTQWLOVP011,~WPI~OSEIACOPatC<<>>11TAAT41ILTEACVPM~wcVOVOELLVW~scaletvwtUNIT1-0.5'AB1000HOURSAFTERACCIDENT'Tl-I<SVPL,~41vIol>>cvolst>>1I~tlalall<<IAIIC~4aclAcv~IOLS<<0Wvto0~OMACO~Oatlalatc(P/HP/20I-FG-R27~Al~ECATIA1CSAAOMOWITOTTwavAcrCOVPEWATElaacoU9)(D(D0COKzKQmOrzOgZITIQ~~tO0)UIzCOQm0IQmz0C0ZZITIX0U)CfTl00ZXI0TlXI0AIllOCIllIfll
UMC)0OmOm0lll(0)0zK0mzU0OxT3'0tjIlt.XIII(All(Cttt(CNNllloooaCAIN(AAL(lYPI(gAoaaAANNNA(oaNNCODI(NII<<CLCj}IalaaaelPAALaANNaaNLNNNa(aWCV(ANIPCN(ta(~ag~g~tl---~OIQ~aooaaaNAONsa'l0IA0AaoeOSOOINL,oatoo(NLrIPRSlojaNaoPALNLSACCNOOACONOgl-5l8L~JO.~0(PiBPiZO1~7)A,NCnANANCNDAAXXCNIN.TK<<aa(CCACAlclOAACCNPl,ONCIC~NCA(CANINCNTNtlcCNILtNL5Dz0)~mAIOgzmQzU)~IO0ICz(6Qfll0zIXIQz00O0z000mOmLESEND:ZONE1CCIYYY(ZONALDOSERATECLASMt(CATIONUPPERUMITDOSERATEN(SMRIHR1S100MRJHR100~1000MRIHR(-(0RIHR10~100RIHR>ICOR/HR~SELOW0FEETUNIT119.5'AB1000HOURSAFTERACCIDENT REACTORCONTAINMENTBUILDING2-RCBUMC)0AOz0IllCD0zz0tttttttt~lNPIttlI4I'ttILt%ttOOOP4O'1~ttla)tttWiltOttttt~ttWttt~ttttttltWtttVIQ/lQOO0OgL'NOTEDOSERATESHIGHERINVICINITYOFPENEIRATIONSANDRADIOACTIVEPIPES.(PiBP/20'~5gI28gmoIDQ22Q~COcCOIC2(0I0mUmQ20U0mO000oOfll=ImLEOEND:ZONEIIIWIIVVVIZONALDOSERATECLASSIFICATIONUPPERLIMITDOSERATEcISMR/HRIS~100MR/HR100~1000MR/HRI-IOR/HR10100R/HRv100R/HRUNIT2-0.5'AB1HOURAFTERACCIDENT
~DICNVVICNHIIL-HlzpIbC)770OOCz0XfllCO0zz0INN//CCN'ciCZNVN/NCCM0NIN/C/I/3..]gIAVI%INN~/IT%MINTCN/OIM/I/N0NC/N/INHCNIVNL'=/P'~10V5~/0CNNV8~NVNMINNIgoOboa.boaNCCCNI~QCCRC/00IONCXCHNNMNI/NCNCHNNMNI5azU)~XpmOIOgzmQ~(0cOICz0)IQmUzQz0m0zmO0z0Tf0OIllOCfll=IfllLEDEND:ZONEIII10IVYVIZONALDOSERATECLASSM/CATIONORNERL/M/TDOSERATE<15MR/HRI0~100MRA/RICO~10COM/LHRI~ICRHR10.100RlHR>100R/HRNOTEDOSERATESfRGRERWVICECITYOFPENETRATlONSANORADIOACTIVERPES.UNIT219.5'AB1HOURAFTERACCIDENTfPiBP/WHVRZI 00lbC)0OO0TTICD0zz01slssccsuLlssccsusevsevs<<usvs~vTcN0>>QccuuscITITPQslwcOCDOO1IIV'::,yAussc<<cVCALevstAsELOPE=~OuUKKQIKMIIDIscNcsIoeWEMC3~.1ecvsetGILssswv/ecuoooouu$("I(hHI~seemccuc,io=Q(PiBPj201-FKHTJ5'azmorzOgzIllQ~Ul~COIz(0Qm0IZmQZOITl(00ZImX0(0CXlmO0zXI00OOCLEGEND:ZONEZONALDOSERATECLASSIFICATIONUPPERLIMITDOSERATE<<ISMR/HR1S~100MR/HR100~1000MRhIR1~10R/HR10~100R/HRs100RhlRUNIT243'AB1HOURAFTERACCIDENT ENO.SASKODAIOSlOOX:CA/NNETSDICITALDATAI'ROCESSORCASWETSP)HZRECOMSINKRCASINET2AHZANALYZERCASWETSREACTORCONTAINMENTBUILDINGUMC)0omOmz0(f/50z0SEEPART.PLAN'A'LEV.INSTRDMENTCASINETSPLANTAVX.CONTROLSCARCSAFETYRKIATKDRADIATIONMONITORPANELSTURBINEBUILDINGIARKDETECTIONPANELSAAF,W.AMTOINT.CAILKK00>>0>>000SAAKE0000tNIOS100IITOS100NTOS100/yNTOSSNWINK~0>>NNT~~0KSESEHSNI>>lATtNISATNjgC!CX3HVA/ACC~SAHVA/ACC~SSSTEATCASUIST10000tANTSNON/TONDEHCONT.CAS.ROD.002RVMRS20.1$RS-2/>>54HOEDQV2D2AHOEDOtTANTO2CRADMONITORENCLOSUREUIDfOID00I5gzOl~ZpmOIZC7+ZCO~CAIt:OIZ0)0mUZQ0mCO0zI0U)XIO0z0I'Tf0OfTIOCfTlfllLECENDIZONEINIVVVIZONALDOSERATECIASSIFICATIONUPPERMMITDOSERATEc1$MR/HRIS100MR/HR1001000MR/HRI10R/HR10ISOR/HR>>100R/HRUNIT262'AB1HOURAFTERACCIDENT(PiBPi205MWZ7hDtD0CQ REACTORCOMTAINMEMTBUILDING2-RCB0omOCmz0Ill010zz0Ii>><<<<<<I<<<<<<IL>><<<<<<~mccoy0V<<<<IY~VICTIMA<<I'<<ri~mI1A0P+6OI01(1I<<iQ~<<<<4>><<>>a>>IPl<<>>~<<<<<<MtLEGEND:ZONALDOSERATECLASSIFICATIONZONEUPPERUNITDOSERATE'OTEDOSERATESHIGHERINVICINITYOFPENETRATIONSANDRADIOACTIVEPIPEROC-fN~Ic7Q(PiBPi20I~.R77KUI2lD~XQmOIOg22Q~(0~COIC2(0I'0mUIQz0m0zzmXt:mO0z0'l700ClCZIIllIIllI0IIIIVVVIcISMR/HR15~100MR/HR100~1000MR/HRI10R/HR10-100R/HR>>100R/HRUNIT2-0.5'AB10HOURSAFTERACCIDENT
~CTCNLCNtalUIbC)0OOZ0m(CO0Z0IN~lLCCl~L'alaIaaa.~LjERIESuse~CNMlNCLLCCLICINCLL~UNM7CCNNXW100ILICINCLLtllallaflaaNXWILILAZ1~CVCfaŽsM~~mIf(II00Naaaal~UQ)(D(DtlcccacaaNN0I5UzM~KQmorzOgzzQ~0Iz0IllUIQmz0ITIU)0Z00)XIO00I'TT0AmOCm=IImLSCTNOLZONSZONALOOSSILATSCLASSUIOATAXIUttTILLSNTOOSCNATE<<15NIALIS~100MILIIN100~1000MICIUL110ILINL10~100IVNII>100ICINLUNIT219.5'AB10HOURSAFTERACCIDENT 00oO0Xill(00Zz0It(DcMs(ISIDOt/seSVSSVSSVS0/SMCSMC.MASMAIIII(MAMC)(MseolGZEEEB0CDOCSCDCXKCCDCSVSK~oeeee0lI.HOL'D~~0eeNelecILEGEND;ZONALDOSERATECLASSIFICATIONZONEUPPERLIMITDOSERATEcISMR/HRIS100MR/HR1001000MR/HR1~10R/HR10~100R/HRP100R/HReevee>>~cellII~eveeee~eeeeeee~<<Il~C3llSIICASSSI,PVu00PI(M/Mz.PI'I/VIFIVVDOOMOoOoQg4-8"-"QOQOCCŽQOfPiBP/20f-FO-R7)UNIT243'AB10HOURSAFTERACCIDENToS(D(D0K0IzUl~molOgZQ~4)0)0IZ(00mDIzmmQz00)0zmX0(DO000AOfllm HTRECOMSINERCASSIETEAHZANALYZERCASINETSENO.SAFEOUARDSLOGICCASdIETSSEEPART.PLAN'A'LEV.OKIITALDATAPROCESSORCASINETS(T)IAP.W.AUTOINT.CAS.IREACTORCONTAINMENTBUILDINGSTACKUMC)0OmOZ0ITiEO0ZZ0PIANTAUXCONTROLSCARDSAFETYREIATEDRADNTIONMONITORPANELSTURBINEBUILDINGIL0*-"FFIEDETECTIONPANEI.SAINSTRUMENTCASSIETS~<<a<<<<<<<<<<<<<<<<~OSIS<<<<~<<<<OL<<LL"KlgAIOSMIPIllddll0Llv1AttEATPALjQCICX3HVA/ACC~SAHVA/ACC~SSAOAYCASNCTl0010PA/ItdNONITOIIOEHCONTCAS.RYMRESISRS44MNOLOUPSOI<<K0UtTAIIIQZCRADMONII'ORENCLOSUREUIK0IzCO~KpmOIXCJgQZM~4)CUIz(0C0mDZmQzOV)0ZZm0mO0Xl000OOm=IfllLEOENDIZONEIIIISIVVVIZONALDOSERATECLASSUICATIONUPPERLIMITDOSERATE<<IdMR/HRld-100MRhlR100~1000MR/HRI~10R/HR10-100R/HRP100R/HRUNIT262'AB10HOURSAFTERACCIDENT[PiBPi20t&P-R27 REACTORCONTAINMENTBUILDING2-RCBxUlbCO00mOz0fllCD0z0LEGEND:ZONEI0IIIIVVVI~sssssssasesss0~sssThiss~spcslllllllmIIIIEmlmmmOOss~ss8-0sssssS0~ssiss'ssaHsssZONALDOSERATECLASSIFICATIONUPPERLIMITDOSERATEc15MR/HR15100MR/HR100~1000MR/HR1~10R/HR10~100R/HR>100R/HRDOSERATESKIGKERINVICINITYOFPENETRATIONSANDRADIOACTIVEPIPES.n0)Qo.-4(PiBPf201%0R7JUNIT2-0.5'AB100HOURSAFTERACCIDENTU(O(DCO00)59Ijz0)~morzDgzIQ~OIZCO0ITl0zmQzO(60ZmXO00I'D0OmOCfll=Im
~IIUIbC)0AmOmz0Ill(EO0z0PLYIACCHoTiWINIIJCCN00COLDPL0wSAIIIWNODAKa)SLSPNCV~wOA5z~HLI%a~IILL~oaowlt00III000"ga~~~a~~tUR(D(DC)05UZCO~KQmOlOgzzQ~I0)~C0Itz(00XIQz00zZmIt:XIO0z000OIllOCmITTIEEOEND,ZONEIII01IVVVlEONAI.DOSERATEOLASSIPCATIONUPPERLIMITDOSERATE~15MAlHR15100MAHA1001000MANAI10RIHR10~100RIHA>>100RHANOTEOOSERATESNIONERINVICINITVCu:PENEWATIONSANORADIOACTIVEPIPES.(PiBP20I~%7)UNIT219.5'AB100HOURSAFTERACCIDENT 0IbC)0OmOm0fllCfl0zz0Ie/Cecal)oaaao~~8~ŽgooWn~Qe)feeae-1~<<e@0-'~)o;ILEOEND)ZONALDOSERATEClASSIFICATIONZONEUPPERLDIITDOSERATE<ISMR/HRI0~100MR/HR100~1000MR/HRI~10R/HR10100R/HR>100R/HRessccH$T.1Mccses)SVSSVSSVIsMci/Aseeee<<epeese)e<<IIIggaI~CACA/CILOG/0'nl~9~Dl<<e<<<<<<e<<Alee/SWCASSSll.Ip!pee<<eeeee<<<<eddaOo-==-O~ele<<<<e~ee<<ee<<(Phd/&II-F&RTPUNIT243'AB100HOURSAFTERACCIDENT5'UIzU)~ZpmOIO+zzQ~CAT(0t:C7ICz(00ITlUZmmQZ000ZZ0MmO00l0CA)M00AmOCfll=Ifll ENO.SAFEGUARDSLOOCCASKETSCKOITALDATAPROCESSORCAS'NETSII)HtRKCOMSINERCASINETTAHKANALYZERCASKETSREACTORCONTAINMENTBUILDINGSTACK0IbCO0OOCz0jlIllCFI0z0AF.W.AUTOINT.PISTRUMENTCASINETSSAFETYRELATEDRADIATIONMONNORPANELSTURBINEBUILDINGII0-'FSIEDETECTIONPANELSASEEPART.PLAN'A'LKV.$CdCCCCIAIOSHCATOCIOI~ICCCCCCSANIOMMANCSoftccjgE3CUCCAACC40MOLCfLEZ+INCATATATAAA.NVACHK.CATHHVAIACCSAHVAIACC.$8AQAYCAIICCTLOOCCCACTINOKKOARV4RSZS1$ROE'4IKKOVATAICKQZSIKK~DVKCCOFCVCNTICAARAOMONITORENCLOSUREU(O(D0CD9I5QIzz+moIZCl+zmQz(0~4lt:UICzCO0mUImQ0m(00zImX0MmO0zXI000OOmmLESEND:ZONEZONALDOSERATECLASSIFICATIONUPPERUNITDOSERATEK1$MRIHIL1$~ICOMRIHR100~1000MRIHR110RIHR10~100RIHR>100RIHRUNIT262'AB100HOURSAFTERACCIDENT REACTORCONTAINMENTBUILDING2~RCBUIbC)0OOm0(fTIf/)0ZR0~WlttlW~~OeKAlIAUIQtlttttt'tt4I1ttLEGEND:ZONEIDDlIVVVlIAttCttttetttt'tIalstttttt~ascttt0OtttPea4Calaswttt~tttttttttt[g(U~,foeQoIIIIIIZHEDO(3~lttt~ttttttItt(PiBP20t~-RTJZONALDOSERATEClASSIFICATIONUPPERLIMITDOSERATE<ISMR/HR1$100MR/HR1001000MR/HAI10R/HR'IO-100R/HA>100R/HRUNIT2-0.5'AB1000HOURSAFTERACCIDENTNOTEDOSERATESHIGHERINVICINITYOFPENETRATIONSANDRADIOACTIVEPIPES.U(OCDCQ0CDKazU)~mOIXOgzzQ~0)c0ICz(0IIt:0m0IQmz0(00zzXIO0zXI0D0offlOCm=Ifll CCAACCAIMlUlbC)00mOC0lll(ED0Zz0WOAC~CIVICCIOAACCAACAAVAIACCN'ciWOVAIACCVCLj~AOAAAC~ecalaI'~)INAOAc~ACA%ACAOAVQCVC0uwzh~~~~-w(fCAOANKVOAOA0go"oVACUAAOVCAOVAANN0Gl(O0-eCAV~OAVVANACO0IK'aIZ(D~KQraorzU~ZzQ~Ul~OICzV)0ITl0rzmQZ0(00Zm00)O00I'll0A0CfllLEOEND:ZONALDOTERATECACCCROATIONZONEUCPERLNNTDOCSRATEc10NRNRNOTE1$~100NRNR100~1000NRHRDOSERATESIEGNERNVIOIMTYOFPENETRATlONSAND110RIHRRADCADTIVEPIPES.10IOORHRA100RIHR(PAP/20MYRTLEUNIT219.5'AB1000HOURSAFTERACCIDENTGOC)04)M 0IbC)0omOmZ0m0)0z0SCCU/STT.SICS/OTCCT.ANOIIAOUONITOIVITALACCACHETl)IOCSOt.ITS)CI>>STSVSSVSSUSTUSSMCIlASIIAIIIIIIlAIIC)COCDaOI=~GA)fa>>a>>~tk>>l00f~0XXB~SUSOO+PpOCQ'-3I>>>>%II0>>t>>>>KA>>>>I~'CD>>>>IA00IIoaItjYYV'ITAOOMOo"=-It0(PiSP201.PW/V7KgIzUl~KpmOIXOgzmQzM~4lC0ICZ(0IQITlUIzQm0XI(00z0V)O0z0'Zl0oillOCfllfllLEGEND:ZONALDOSERATEClASSIFICATIONZONEUPPERLIMITDOSERATEc1$MR/HRI5~100MR/HR100~1000MR/HRI~10R/HR10~100R/HR>100R/HRUNIT243'AB1000HOURSAFTERACCIDENT ENO.SAFEOUARDSLOGICCASTANETSDIOITALDATAPROCESSORCASKETS(TlAF.W.AUTOINT,H2RECOMSINERCAMNET2AHZANALYZERCAST/ETCREACTORCONTAINMENTBUILDINGSTACK0OmOCmZ0m0)0zK0SEEPART.PlAN'A'LEV.SZINSTRUMENTCAINNETS20/TURBINEBUILDINGiIFIANTAUX.CONTROLSCARCSAFETYREIATEDRADIATIONMONITORPANELSIj*-LLFIREDETECTIONPANELSAMDMCHYE11MrcMM/rrerr17041IHgATCCICF.jgQC!OHVEISAHVA/ACC~SAHVA/ACCARArcAC/r2110022PANTSIKMCCARS24-14DEHCONT.CAS.HVS~SA//C2OFCrt//14CAC.RS40.20.RADMONITORENCLOSURE5Iz0)~ZpmOIOgzzQ~0)OC0ICzCD0fll0zQZ00zZmICO000AOITi=ImLESEND:ZONEIII21IYVVlZONALDOSERATECIASSIFICATIONUPPERUMITDOSERATEc14MR/HR14100MR/HR100~1000MIVHRI-10R/HR10~100R/HRv100RHRUNIT262'AB1000HOURSAFTERACCIDENT(PiBPIEOI.FX.FI7$
y$$~@gJ~gp~i~f~fgp)p5Title:FPLy~~>~a~~~4'++0ST.LUCIEPLANTEMERGENCYPLANIMPLEMENTINGPROCEDURESAFETYRELATEDProcedureNo.EPIP-11Currentev.No.2ectiveDate:03/27/0tCOREDAMAGEASSESSMNTResponsibleDartment:RevisionSummryEMERGENCYPLANNINGRevision2-RemodY2Kcautionstatements.Madeed'rial/administrativechanges.(J.R.Walker,03/22/0Revision1-Addedcau'statementtoensurepropuseofthecoredamageassessmentprogram,corndmakeitY2Kready..Walker,06/30/99)PSLP<<~DU~<RtODUCTiO~RevisionFRGReviewate12/197RevisionFReviewDate03/22/01ApprovedByJ.ScarolaPlantGeneralManagerApprovedByR.G.WestPlantGeneralManagerN/ADesignatedApproverN/ADesignatedApprover(MinorCorrection)AprovalDate117/97Approvalate03/22/01SOPSDATEDOCTPROCEDUREDOCNEPIP-11SYSCOMPCOMPLETEDITM2 f
REVISIONNo.:PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTTABLEOFCONTENTSPAGE:2of83SECTIONPAGE1.0PURPOSE~~~~
32.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTS...~..~...~..................~...~~~.....43.0RESPONSIBILITIES.~......~.~..~........~...~.~.~.~...53.1EmergencyTechnicalManager..~...................~..53.2EOFNuclearFuelsEngineer.......................~..54.0DEFINITIONS...~......~...~~~~~~~~65.0INSTRUCTIONS.~...~..~~..~...~~~..~.............~.~~7ATTACHMENTSATTACHMENT1CharacteristicsofNRCCategoriesofFuelDamage.........~.........~....~.10ATTACHMENT2CoreDamageAssessmentUsingtheComputerCodeCord.................~.....~.~..13ATTACHMENT3SoftwareTestCaseforSt.LucieUnits182...23ATTACHMENT4PreliminaryEstimateofCoreDamageUsingCoreExitThermocouple(CET)Temperatures..38ATTACHMENT5PreliminaryEstimateofCoreDamageUsingRadiationDoseRates...~.~.~~...~...~..~43ATTACHMENT6PreliminaryEstimateofCoreDamageUsingPreliminaryRadioisotopicData.......~.~...50ATTACHMENT7PreliminaryEstimateofCoreDamageUsingHydrogen.........................~..~53ATTACHMENT8DetailedRadiologicalAnalysis...67 REVISIONNO.:PROCEDURENo.:PROCEDURETITLE:COREDAMAGEASSESSMENTPAGE:3of83EPIP-111.0PURPOSEST.LUCIEPLANT1.1ThisprocedureidentifiestheresponsibilityandmethodologytoperformcoredamageassessmentforSt.LucieUnits1and2.Methodsforestimatingcoredamageassessmentarebaseduponpost-accidentradionuclideconcentrationswithintheReactorCoolantSystem(RCS)andcontainment,andotherplantindicators,includingcoreexitthermocoupletemperatures,hydrogenintheRCSandincontainment,andContainmentHighRangeRadiationMonitor(CHRRM)readings.1.2AnestimateofcoredamagemaybeusedtoassistinvalidatingProtectiveActionRecommendations(PARs),severityofplantconditions,and/orrecoveryoperations.1.3Thisprocedureincorporatesinstructionsforhandcalculationsand/orfortheuseofcomputersoftwareintheanalysisofrelevantplantdatafollowinganaccident.1.4ThisprocedureisonlyusedtoobtainanestimateofcoredamagewithinamajorfueldamagecategoryasidentifiedbytheNRCinNUREG-0737.ThecategoriesaredefinedinAttachment1tothisprocedure.1.5Adetaileddiscussionofthebasisforthecoredamageassessmentmethodologyisincludedinreference2.1.2.
REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:COREDAMAGEASSESSMENTPAGE:4of83EPIP-11ST.LUCIEPLANT
2.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTSNOTEOneormoreofthefollowingsymbolsmaybeusedinthisprocedure:gIndicatesaRegulatorycommitmentmadebyTechnicalSpecifications,ConditionofLicense,Audit,LER,Bulletin,etc.,andshallNOTberevisedwithoutFacilityReviewGroupreviewandPlantGeneralManagerapproval~Indicatesamanagementdirective,vendorrecommendation,plantpracticeorothernon-regulatorycommitmentthatshouldNOTberevisedwithoutconsultationwiththeplantstaff.2.1ReferencesSt.LuciePlantRadiologicalEmergencyPlan.2.Developmentofthecomprehensiveprocedureguidelineforcoredamageassessment.CEOwnersGroupTask467,July1983.(IncludedinReference2.1.5).3."CORDVersion1A-CoreDamageAssessmentComputerProgramforSt.LucieUnits1and2,"IMPELL/FPL-85-116,June3,1985.4.JPNCalculationNo.PSL-BFJF-91-008,"DeterminationofFissionProductSourceInventoriesforPSLforCoreDamageAssessment,"Rev.0,Approved3/11/91.5.FPLLetter,M.JimeneztoR.D.Mothena,"CoreDamageAssessmentProcedure,EPIP-1302,Revision3Documentation,"May17,1995,NF-95-330.6.US-NRCNUREG/BR-0150,Vol.1,Rev.3,"ResponseTechnicalManual,RTM-93,"November1993,PageB-16(includedinReference2.1.5).
REVISIONNo.:PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:5of8
32.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTS(continued)2.2RecordsRequired1.Duringanactualemergency,informationusedtoestimatecoredamage,includingappropriateworksheets,willbemaintainedbytheEmergencyTechnicalManagerorhisstaffdesigneeattheEmergencyOperationsFacility(EOF),orbytheReactorEngineerintheTechnicalSupportCenter(TSC)~2.AllwritteninformationwillbeforwardedtotheEmergencyPreparednessrepresentativeattheTSCorEOF.2.3CommitmentDocuments1.ClarificationofTMIActionPlanRequirements.NUREG0737,ItemII.B.3.3.0RESPONSIBILITIES3.1TheEmergencyTechnicalManagerensurestheperformanceofcoredamageassessmentusingthemethodologyinthisprocedure.3.2TheEOFNuclearFuelsEngineerperformscoredamageassessmentusingtheguidelinesinthisprocedureandengineeringjudgement.
REVISIONNO.:2PROCEDURENO.:PROCEDURETITLE:COREDAMAGEASSESSMENTPAGE:6of83EPIP-114.0DEFINITIONSST.LUCIEPLANT4.1NoCoreDamaereferstoacorestateinwhichtheintegrityofthefuelrodcladdingisintactandtheonlyreleaseoffissionproductstotheReactorCoolantSystemisthatduetopre-existingfuelroddefectsandiodinespiking.FuelRodCladdinFailurereferstoacorestateinwhichthefuelrodcladdingofsomefractionofthefuelrodsinthecorehasfailed,resultinginthereleaseofthefissionproductsinthefuelrodgapspaceofthefailedfuelrodstotheReactorCoolantSystem.FuelOvertemeratureDamaereferstoacorestateinwhichthefuelpelletshavereachedatemperaturewherethereisarapidmovementoffissionproductsfromthefuelpelletmatrixtotheReactorCoolantSystem.100%FuelRodCladDamaereferstotheruptureofthefuelrodcladdingin100%ofthefuelrodsinthecoreandtheresultantreleasetotheReactorCoolantSystemofallfissionproductscontainedinthefuelrodgapspace.100%FuelOvertemeratureDamaereferstohightemperaturesinthefuelpelletsin100%ofthefuelrodsinthecoreandtheresultantreleasetotheReactorCoolantSystemoffissionproductscontainedinthefuelpelletmatrix.EmerencResonseDataAcuisitionandDislaSstemERDADSalsoknownastheSafetyAssessmentSystem(SAS)andincludestheSafetyParameterDisplaySystem(SPDS)servesasaconcentrateddatasourcethatpermitsEOFpersonneltoobtaindesiredinformation(plantparameter,radiological,meteorological,etc.)inarapid,accurate,andconvenientmanner.
REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:COREDAMAGEASSESSMENTPAGE:7of83EPIP-115.0INSTRUCTIONSST.LUCIEPLANTNOTEAvailablepertinentplantdataneededtoperformthecoredamageassessmentshouldbeprovidedthroughtheERDADSand/orcommunicationswiththeTSC.5.1TheEOFNuclearFuelsEngineerwillperformthecoredamageestimateusingthemethodologydescribedinthisprocedure.NOTE~Computergeneratedestimateisthepreferredoptionforassessingcoredamage,sincethehandcalculationsarelengthyandcomplex.~Thehandcalculationmethods,Attachments4,5,6,7and8,areprovidedforbackuppurposes.5.2CoredamageassessmentwillbeperformedusingAttachment2.1~Attachment2providesinstructionsfortheexecutionofcomputerprogramstodetermineassessmentofcoredamage.2.ThecomputersoftwaretestcaseisprovidedinAttachment3.3.Whenneeded,theTSCstaffmayperformacoredamageestimateusingtheindicatorsdiscussedinAttachments4,5,6and7.5.3Allpertinentdataavailableshouldbeusedinestimatingcoredamage,includingthefollowing:Radionuclidedata2.AuxiliaryindicatorsA.CoreExitThermocouple(CET)temperatureB.HydrogenintheRCSandcontainmentC.ContainmentHighRangeRadiationMonitor(CHRRM)readings REVISiONNo.:PROCEDURENO.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:8of835.0INSTRUCTIONS(continued)CAUTION~Theassessmentofcoredamageobtainedbyusingtheattachedmethodologyisonlyanestimate.Thetechniquesemployedareonlyaccuratetolocatethecoreconditionwithinoneormoreofthe10categoriesofcoredamagedescribedinTable1inAttachment1.~Coredamageassessmentusingindicatorsthatarereadilyavailable(e.g.,CHRRM)representsonlypreliminaryestimates.Otherplantindicators(e.g.,radionuclideconcentrations)shouldbeobtainedtoimproveuponestimationofcoredamage.~Measurementsobtainedduringrapidlychangingplantconditionsshouldnotbeweighedheavilyintotheassessmentofcoredamage.Ifdeemednecessary,thesepertinentindicatorsshouldbemeasuredwithinaminimumtimeperiod,particularlyduringrapidlychangingconditions.Itisrecommendedthatmeasurementsbemade,ifpossible,whenplantconditionsstabilize.5.4ResultsintermsoffuelconditionshouldbeprovidedtotheEmergencyTechnicalManager(ETM),theRecoveryManager(RM),andtheEmergencyCoordinator(EC)astimelyaspossible.1~Thetypeofcoredamageisdescribedintermsofthe10NRCcategoriesdefinedinTable1inAttachment1~2.Inthecaseofradionuclideanalysis,thedegreeofcoredamageisdescribedasthepercentofthefissionproductsinthesourceinventoryatthetimeoftheaccidentwhichisnowinthesampledfluidandthereforeavailableforreleasetotheenvironment.
REVISIONNo.:PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:9of835.0INSTRUCTIONS(continued)5.5UpdatedestimatesofcoredamagemayberequestedperiodicallybytheETM,theRMortheECasplantconditionschangeand/orstabilize.1.Theseupdatesshouldbeperformedusingthemostrecentavailabledata.2.ResultsshallcontinuetobereportedtotheETM,theRMandEC.ENDOFSECTION5.0 REVISIONNO.:PROCEDURENO.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:10of83ATTACHMENT1CHARACTERISTICSOFNRCCATEGORIESOFFUELDAMAGETABLE1.CHARACTERISTICISOTOPES00-OCOU-KUI-COOP0~gI-Z2LlJ~/X~>>IXOZKLUa.a.O~gUJUJUJK~<0COKXI-~WOQQCOCO1CdCDCDCDoCcdCDCDCDoIA0ooIACCdLCDCdIolCC5CDCDCDoIA0ooIACcdIC5I(9oCCDCDoIACC5CD5$CD0I-COKaLll0I-I00K-'(COz0COTCD0KCOCCJCDCOXIE~COv-1IIXCA-CIJKI-gCDTPICD0I-o41TCb~Q.o<TCdCdLaALllCO20~0CO~IJJCOCOZLLJcC2ZUJOKUJ20c$)E'0CCO2CDO)oEcdgI-ILDPgKICDcd.0D(gCDcd00CdDCOOCD(9CD0epIgE-CD~UCdOCD~LUK(9I00+0U.K~Z0CdECd0C)U0Z0>CcdC$)0'0C5D5$Ogac5CDcdUC$$Dcd00C5CDa.c$$CIC5UCDCQCDQ.IDUC$$C5CQCD(LC$)CCD-a~~CDWOCDKCDU06$o$5ZUJUJI-(g<0C06$.-EmOCDZ00)~Cd0cd0Ie0)CDa-Cd0~60cd0 REVISIONNO.:2PROCEDURENO.:PROCEDURETITLE:COREDAMAGEASSESSMENTPAGE:11of83EPIP-11ST.LUCIEPLANTATTACHMENT1CHARACTERISTICSOFNRCCATEGORIESOFFUELDAMAGETABLE2.CLADDINGDAMAGECHARACTERISTICSNRCCategoryofFuelDamage1.NoFuelDamage2.InitialCladdingFailureTemperatureRange(F)approximately750MechanismofDamageNoneCharacteristicMeasurementN/AMeasurementRangeN/Alessthan1550F*PercentofDamageRodslessthan1lessthan103.IntermediateCladdingFailure4.MajorCladdingFailureRuptureDue1200to1800toGasGapOver-pressurizationMaximumCoreExitThermocoupleTemperaturelessthan1700F*lessthan2300Flessthan2percentOxidation10to50greaterthan505.InitialFuelPelletOverheating6.IntermediateFuelPelletOverheating7.MajorFuelPelletOverheating1800to3350LossofStructuralIntegrityDuetoFuelCladOxidationAmountofHydrogenGasProduced(EquivalenttoPercentOxidationofCore)EquivalentCoreOxidationlessthan3percentlessthan18percentlessthan65percentlessthan1010to50greaterthan50*DependsonReactorPressureandFuelBurnupValuesGivenforPressurelessthanorequalto1200psiaandBurnupgreaterthanorequalto0.
REVISIONNO.:PROCEDURENO.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:12of83ATTACHMENT1CHARACTERISTICSOFNRCCATEGORIESOFFUELDAMAGETABLE3.PERCENTOFSOURCEINVENTORYRELEASEDTOCONTAINMENTU0ZI-zz0Z(0LllI=QOZD(0g~IZ)(0~IKU-OZI-KQ(00.OOQ)EEE00Q$Sl0zCQ)C)E~<<CP-CQ)Dl06$xCQ$OQ)5$a.CdCACD$OC5-0~(0CQQ$C5$'O~06Q$aD.Q$CdCA0.0-Cd~UJO(OI-0~~(0LUZUK-0>-I-I-KZZooUJI-OOZpKLU~0ZTCCd0)CQQ)ClCcdJ=5$0$Q)lDCAoCAOL0CdQ$(9C)TCCdJ:V)CoQ)C)CA0CDTOCAC:CdCdQLULU(0O~KIllDIlJQK~LlJLJJ(OQKzm~pggoZLUSOKpIllUKMOUO$p0C6$DK~0ECdcd~I-CocdcdcdV)(gg)v)OCQ,O'D(grnCdOClC5D0CoKl~.EoCd(9COEcdac~U-'Cd0'v)6(9CdcvOKD~IlJKG0~IOOLJJOUzU0CdEOU0ZCdUD)OcdOCdD)O'OCdOd)C5OQ)ECCdCdUD)OCdO0CdQ)Q$(LO$CQ)CdQ)QD)Q$CLDCdQ)6JOQ~Q$Q)Q)=Q$Q$0-D$CQ)-C5a0~~Q$XO REVISIONNO.:PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:13of83ATTACHMENT2COREDAMAGEASSESSMENTUSINGTHECOMPUTERCODECORD(Page1of10)1~PurposeThissectionprovidestheinstructionsfortheuseofthecomputercodeCORDinperformingcoredamageassessment(Reference2.1.3).ThiscodeautomatesthefunctionsdescribedinAttachments4through8.2.PrecautionsandLimitationsA.AssignedengineersareresponsibletofollowtheinstructionsofthisprocedurewheneverperformingcoredamageassessmentforSt.LucieUnits1and2.B.Priortouseofthecode,validationmustbeperformedbyrunningthebenchmarkcasesprovidedinAttachment3.3.SpecificInstructions/R2Readandbecomefamiliarwiththedetaileduserinstructionsprovidedinparagraph1,Dofthisattachment.TheseuserinstructionsaregenericinnatureandwillprovidetheuserwithageneralunderstandingofhowCORDworksanddescriptionoftheinputtypesandeditingkeys.Theinstructionsaredesignedtocomplementtheuserinstructionsandminimizetheneedforfamiliarityintheeventofanactualemergency.Consequently,theseinstructionsaremorespecifictothehardwareequipmentdesignatedforcoredamageassessmentuse.A.Setupthecomputerandprinter.B.ExecutethecomputerprogramCORD(orlaterrevisionname).C.PerformprogramvalidationbyrunningthebenchmarkcasesprovidedinAttachment3.
REVISIONNO.:PROCEDURENO.:PROCEDURETITLE:COREDAMAGEASSESSMENTPAGE:14of83EPIP-11ST.LUCIEPLANTATTACHMENT2COREDAMAGEASSESSMENTUSINGTHECOMPUTERCODECORD(Page2of10)3.SpecificInstructions(continued)D.ObtainfromERDADSand/orotheravailabledatasourcethefollowinginformation:1.Unit,dateandtimeofreactorshutdown2.Powerhistorypriortoaccident3.Coreexittemperatures4.Containmentradiationdoserates,and5.PASS(Post-AccidentSamplingSystem)sampleandwhetheritiscorrectedtostandardtemperatureandpressure(STP).E.BegincoredamageassessmentbychoosingOption7toselecttheappropriateunit.ProceedtoexecuteOptions1through4asdatabecomesavailable.Basedontypicalaccessibilityofdata,themostlikelysequenceisasfollows:1.Option3-"CoreExitTemperature"2.Option4-"RadiationDoseRate"3.Option1-"RadiologicalAnalysis"4.Option2-"Hydrogen" REVISIONNO.:2PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:15of83ATTACHMENT2COREDAMAGEASSESSMENTUSINGTHECOMPUTERCODECORD(Page3of10)3.SpecificInstructions(continued)F.RunningOption3(CoreDamageAssessmentUsingCoreExitTemperatures)1.Entermaximumcorethermocoupletemperature('F).Notethatifthistemperatureissignificantlyhigherthantheaverage,itmayindicateafaultythermocouple.Inthiscase,disregardtheabnormallyhighreadingandusetheaverageoftherestofcoreexitthermocoupletemperatures.2.EnterRCSpressure(psia)correspondingtothetimeofthetemperaturereading.3.ReviewthecalculatedpercentofrupturedcladagainstthoseincludedonTable1inAttachment1todeterminetheappropriateNRCdamagecategory.NotethecautionandnoteincludedintheCORDoutputpageforthisoption.G.RunningOption4(CoreDamageAssessmentUsingRadiationDoseRate)1.Choose"1"toretrievepreviousinputdata.Revisetheinputdatawithnewinformation.Enterdateofreactorshutdown(mm-dd-yr)andtimeinmilitarytime(00:00)./R2 REVISIONNO.:PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:16of83ATTACHMENT2COREDAMAGEASSESSMENTUSINGTHECOMPUTERCODECORD(Page4of10)3.SpecificInstructions(continued)G.RunningOption4(CoreDamageAssessmentUsingRadiationDoseRate)2.Enterrepresentativepowerlevelinpercentusingengineeringjudgement.Notethatthemostrecentpowerlevelsshouldbeweightedmorethanthepastlevels.3.Enterthehigherofthetwomeasuredcontainmentdoserates(Rad/Hr)withcorrespondingdatesandtimes.4.PrintscreenandreviewthecalculatedresultsagainstthecorrelationsincludedonFigure5-1,ContainmentHighRangeMonitorDoseRatevs.TimeAfterTrip,toconfirmtheappropriateNRCdamagecategory.5.ContinuetoexecutethisoptionasmoredatabecomesavailablebyaddingnewsetsofdataasinStep3.G.2.H.RunningOption1(RadiologicalAnalysisofSamples)1.Choose"1"toretrievepreviousinputdata.Revisetheinputdatawithnewinformation.Enterdateofreactorshutdown(mm-dd-yr)andtimeinmilitarytime(00:00)~/R22.Enterpowerhistory,includingpowerlevelinpercentandnumberofdaysateachlevel,endingwiththemostrecentpowerlevel.
REVISIONNO.:2PROCEDURENO.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:17of83ATTACHMENT2COREDAMAGEASSESSMENTUSINGTHECOMPUTERCODECORD(Page5of10)3.SpecificInstructions(continued)H.RunningOption1(RadiologicalAnalysisofSamples)(continued)3.EnterPASSsampledataasavailablefor:RCSHotLeg,ContainmentAtmosphereorContainmentSump.ThisdataconsistsofmeasuredactivityinmicroCuriespergram(pCi/g).4.EnterproperresponseforcorrectiontoSTPinaccordancewithinformationprovidedwiththePASSsampledata.5.Performdecaycorrectionasappropriatebyentering"yes."6.PresstheF1keytocontinuethroughthe"RECORDOFDECAYCORRECTIONACTIVITYRATIOS."7.Printscreenthe"RECORDOFFISSIONPRODUCTRELEASESOURCEIDENTIFICATION"anddeterminetheappropriatesource(gasgaporfuelpellet)bycomparingthecalculatedratiostothoseinDataSheet8-3,RecordofFissionProductReleaseSourceIdentification.8.PresstheF1tocontinueandenterthefollowinginformationaspromptedbytheprogram:-reactorwaterlevel(full,void,orbelowrecorder)-SafetyInjectionTank(SIT)volumeinjected(gallons)-BoricAcidMake-upTank(BAMT)volumeinjected(gallons)-changeinRefuelingWaterTank(RWT)volume(gallons)ThisinformationisobtainedfromMechanicalEngineeringattheEOF.9.Pressreturntoobtainthe"RECORDOFRELEASEQUANTITY."PrintscreenandpressF1toobtainthe"RELEASE(percent)OFGASGAPANDFUELPELLETINVENTORY."
REVISIONNo.:2PROCEDURENo.:PROCEDURETITLE:COREDAMAGEASSESSMENTPAGE:18of83EPIP-11ST.LUCIEPLANTATTACHMENT2COREDAMAGEASSESSMENTUSINGTHECOMPUTERCODECORD(Page6of10)3.SpecificInstructions(continued)H.RunningOption1(RadiologicalAnalysisofSamples)(continued)10.PrintscreenandusetheseresultsinconjunctionwiththeisotoperatioevaluationofStep3.H.7todeterminethecategoryofcoredamageinaccordancewithTable1,CharacteristicIsotopes,inAttachment1.I.RunningOption2(CoreDamageAssessmentUsingHydrogen)1.Choose"1"toretrievepreviousinputdata.Revisetheinputdatawithnewinformation.EnterpercentvolumeofHydrogenincontainmentandtemperatureandpressureatsampling.2.Enterpost-accidentcontainmenttemperaturehistoryasavailable.3.EnterRCSsampleinformationasprompted.Notethattheinputrequiresanestimateofcoredamagebasedontheevaluationofotherparameters(Options1,3and4).4.Enterdataonreactorvesselheadvoid,includingestimateofvoidvolume.5.ContinuebypressingtheF1keytoobtainasummaryoftheHydrogenanalysis.UsetheseresultsalongwithTable2,CladdingDamageCharacteristics,inAttachment1todeterminethecategoryofcoredamage.4.GenericCORDUserInstructionsA.IntroductionCORDisacomputerprogramwhichperformsthecalculationsfortheSt.LucieUnits1and2inaccordancewiththisprocedure.TheprogramiscompiledusingIBMcompilerBASICandcanberunusingtheIBMBASICinterpreter.TheCORDdiskettecontainsthefollowingfiles:CORD.BASTheCORDprogramsourceBASICsourcecodeCORD.EXETheCORDexecutablefileCORDPSL1.DATTheSt.LucieUnit1datafileCORDPSL2.DATTheSt.LucieUnit2datafile REVISIONNo.:PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:19of83ATTACHMENT2COREDAMAGEASSESSMENTUSINGTHECOMPUTERCODECORD(Page7of10)4.GenericCORDUserInstructions(continued)B.GettingStartedTousetheCORDprogram,takethefollowingsteps:1.BootupthecomputerusingDOS2.0orhigherversion.2.InserttheCORDdisketteinaPCdrive.C.3.ProceedtoloadtheprogrambytypingCORD,themainmenushouldappear.ProgramOptionsThemainmenuforCORDcontainsthefollowingoptions:1.RADIOLOGICALANALYSISOFSAMPLES2.COREDAMAGEASSESSMENTUSINGHYDROGEN3.COREDAMAGEASSESSMENTUSINGCOREEXITTEMPERATURES4.COREDAMAGEASSESSMENTUSINGRADIATIONDOSERATE5.UPDATEEQUILIBRIUMSOURCEINVENTORY6.EXITPROGRAM7.TOGGLEFORAPPLICABLEUNITThefirstfouroptionscorrespondtothefourtypesofcoredamageassessmentcalculationsoutlinedinthisprocedure.Theinputsandcalculationswillnotbediscussedhere,butaredescribedelsewhereinthisprocedure.ThefifthoptionallowstheusertochangetheequilibriumRCSsourcesusedbyOption1.Oncechanged,theolddataisdiscardedandallfutureexecutionoftheprogramwillusethelatestequilibriumsourcedataentered.Notethattheolddatacanbepreservedbycopyingthedatafiletoanotherfilenamebeforeexecutingtheprogram.
REVISIONNO.:PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:20of83ATTACHMENT2COREDAMAGEASSESSMENTUSINGTHECOMPUTERCODECORD(Page8of10)4.GenericCORDUserInstructions(continued)C.ProgramOptions(continued)TheuserselectsOption6toexittheprogramandreturntotheDOSoperatingsystem.ThecalculationsareidenticalforSt.LucieUnits1and2,buteachunitwillhavedifferentinputdata.TheuserselectsOption7tospecifytheunitforthecurrentrun.D.DataFilesThetwodatafiles"CORDPSL1.DAT"and"CORDPSL2.DAT"storethemostrecentlyenteredequilibriumsourcedataandprograminputdataforUnits1and2,respectively.MostOptionsoftheprogramwillasktheuserifthecalculationsaretousethelastdatasetorwhetheranewdatasetistobeentered.Ifthelastdatasetoptionisselected,thedataisrecalledfromtheappropriatedatafilefortheselectedunitandisusedasthedefaultentryforallinputs.Whenanewdatasetisentered,itwillbewrittenoverthedatacurrentlyinthedatafile.E.InputTypesTheCORDprograminputsareoffourbasictypes:numeric,data,time,andyes/noresponses.numericdataNumberscanbeenteredasintegers,floatingpointnumbersorinscientificnotation.Examplesofacceptableformatsfornumericentriesare:-123,1.23,.123,1.2E-4,and-1.23E-4.Theletter"E"means"times10tothepowerof."Numberswillberightjustifiedintheinputfieldifacceptedbytheprogram.
REVISIONNo.:PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:21of83ATTACHMENT2COREDAMAGEASSESSMENTUSINGTHECOMPUTERCODECORD(Page9of10)4.GenericCORDUserInstructions(continued)E.InputTypes(continued)/R2datestimesAlldateentriesinCORDareintheMM-DD-YYformat,whereMM=twodigitmonth,DD=twodigitday,andYY=twodigityear.The"-"areoptionalandcanbereplacedbya"/"oraspace.ExamplesofacceptabledateinputsusingApril2,1985are:4/02/85,40285,4-02-85,and4285.Timeentriesareassumedtobemilitarytimerangingfrom0:00to23:59.Acceptableentriesare:100,1:00,14:23and1630.yes/noAnswersto"yes/no"questionsareeither"Y"or"y"for"yes,"or"N"or"n"for"no."
REVISIONNo.:PROCEDURENO.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:22of83ATTACHMENT2COREDAMAGEASSESSMENTUSINGTHECOMPUTERCODECORD(Page10of10)4.GenericCORDUserInstructions(continued)F.EditingKeysMostentriestotheCORDprogramaremadeoninputscreensfilledwithdataentryfields.Thesefieldsarethewhitebackgroundareasofthescreen.Theprogramlimitstheusertotypingwithinthefieldareas,butalsoprovidesspecialeditingkeysfortheusertomovefromfieldtofield.~KeESCFunctionClearstheinputfieldandplacesthecursorintheleftmostlocationwithinthefieldBACKSPACEDELDeletesthecharactertotheleftofthecursorDeletesthecharacteratthecurrentcursorlocationRETURNConcludesthecurrententryandmovesthecursortothenextfieldHOMEENDUPARROWMovesthecursortothefirstfieldonthescreenMovesthecursortothelastfieldonthescreenMovesthecursortothepreviousfieldDOWNARROWMovesthecursortothenextfield(performsthesameasaRETURN)LEFTARROWMovesthecursoronespaceleftRIGHTARROWMovesthecursoronespacerightFUNCTIONKEYSThefunctionkeys(F1throughF10)havespecialusesidentifiedatthebottomoftheinputscreen REVISIONNO.:2PROCEDURENO.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:23of83ATTACHMENT3SOFTWARETESTCASEFORST.LUCIEUNITS1&2 REVISIONNo.:2PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTATTACHMENT3CORDBENCHMARKRUNS(Page1of14)PAGE:24of83PROGRAMINPUTFOROPTION1(Page1of2)GENERALINFORMATIONENTERDATEANDTIMEOFREACTORSHUTDOWNDATE:7/18/84TIME:1:00%POWER7550100NO.OFDAYS22172Theseentriesshouldbeinchronologicalorder.Thelastentryistheintervalpriortoreactorshutdown.RECORDOFSAMPLESPECIFICACTIVITYSampleNumber:DateofAnalysis:TimeofAnalysis:Temperature,DegF:Pressure,PSIG:RCSHOTLEG0017/18/844:003001600CONT.ATMOS.0027/18/844:00150.5CONT.SUMP0037/18/844:00150~5SAMPLEACTIVITIES(Ci/cc)KR871XE131M1XE133100I13110000l1321I133100l1351CS1341RB881TE1291000TE1321SR89BA1401LA1401LA14210PR1441.01.01.1.1.01.001.01.01.01.01.01.01.01.01.01.01.1.00001100.1.1.1.110.1.1.1.1F1=DONEF3=PREYSCREENF10=QUIT REVISIONNO.:PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTATTACHMENT3CORDBENCHMARKRUNS(Page2of14)PROGRAMINPUTFOROPTION1(Page2of2)GENERALINFORMATIONPAGE:25of83ENTERREACTORLEVELCONDITION:1.FULL2.VOID3.BELOWRECORDERENTER1,2,OR3)1ENTERSAFETYINJECTIONTANKVOLUMEINJECTEDINGALLONS)0ENTERBORICACIDMAKEUPTANKVOLUMEINJECTEDINGALLONS)0ENTERCHANGEINVOLUMEOFTHEREFUELINGWATERTANKINGALLONS)
REVISIONNo.:PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTATTACHMENT3CORDBENCHMARKRUNS(Page3of14)OPTION1(OUTPUT)(Page1of7)PAGE:26of83CORD-COREDAMAGEASSESSMENTPROGRAMVERSION1A(5/31/85)RUNTIME:01-29-199313:09:20ENCLOSUREA4-UNIT:PSL1RECORDOFDECAYCORRECTIONTIMEOFREACTORSHUTDOWN:7/18/841:00(*)-indicatesthatdecaytimeistoolongtobackcalculateconcentrationisotopeDecayConst(1/SEC)STP(pCi/cc)RCSCORRECTED(pCi/cc)CONTATMOSCONTSUMPISTPCORRECTEDISTPCORRECTED(pCi/cc)(pci/cc)(pCi/cc)(pCi/cc)KR87XE131MXE1331131l132l1331135CS134RB88TE129TE132SR89BA140LA140LA142PR1441.5E-041.04E+006.7E-071.04E+001.5E-061.04E+029.9E-071.04E+048.4E-051.04E+009.3E-061.04E+022.9E-051.04E+001.1E-081.04E+006.5E-041.04E+001.7E-041.04E+032.5E-061.04E+001.6E-071.04E+006.3E-071.04E+004.8E-061.04E+001.2E-041.04E+016.7E-041.04E+005.24E+001.04E+001.05E+021.05E+042.57E+001.15E+021.42E+001.04E+001.16E+036.51E+031.07E+001.04E+001.04E+001.09E+003.79E+011.44E+031.20E-026.06E-021.00E-015.05E-011.20E-021.21E-021.00E-011.01E-011.20E-011.22E-011.00E-051.02E-051.20E-011.21E-011.00E+021.01E+021.20E-022.97E-021.00E-012.48E-011.20E-031.33E-031.00E-011.11E-011.20E-021.64E-021.00E-011.37E-011.20E-021.20E-021.00E-011.00E-011.20E-021.34E-011.00E-011.12E+021.20E-027.52E-021.00E+016.27E+011.20E-021.23E-021.00E-011.03E-011.20E-021.20E-021.00E-011.00E-011.20E-021.21E-021.00E-011.01E-011.20E-021.26E-021.00E-011.05E-011.20E-024.38E-021.00E-013.65E-011.20E-021.66E-011.00E-011.39E+02Preparedby:Checkedby:Date:~~Date:~~Approvedby:Date:~~
REVISIONNO.:2PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTATTACHMENT3CORDBENCHMARKRUNS(Page4of14)OPTION1(OUTPUT)(Page2of7)PAGE:27of83CORD-COREDAMAGEASSESSMENTPROGRAMVERSION1A(5/31/85)RUNTIME:01-29-199313:09:24UNIT:PSL1USETHESERATIOSTODETERMINESOURCEOFRELEASEBYCOMPARINGTHERESULTSTOTHEPREDICTEDRATIOSINENCLOSUREA5.NOBLEGASRATIOS:KR87XE131MXE133RCSSAMPLE0.04970.00991.0000CONTATMOSOA9720.09911.0000SUMP%49718.9020%9910.76171.0000IODINES:l1311132l13311351.00000.00020.01090.00011.00000.24510.01090.13531.0000.00250.00110.0014Preparedby:Checkedby:Approvedby:Date:~~Date:~~Date:~~
REVISIONNo.:2PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTATTACHMENT3CORDBENCHMARKRUNS(Page5of14)OPTION1(OUTPUT)(Page3of7)PAGE:28of83CORD-COREDAMAGEASSESSMENTPROGRAMVERSION1A(5/31/85)RUNTIME:01-29-199313:09:28ENCLOSUREA5-UNIT:PSL1RECORDOFFISSIONPRODUCTRELEASESOURCEIDENTIFICATIONSAMPLENUMBER:001LOCATION:RCSHOTLEGKR875.24E+00XE131M1.04E+00XE1331.05E+02l1311.05E+04DecayCorrIsotopeSpecActivity(EnclA4)pCI/ccCalculatedIsotRatio4.97E-029.91E-031.00E+001.00E+00FuelPelletInventory0.20.0031.01.0ACTRatioinGasGap0.0010.001-0.0031.01.0IdentifiedSourcel1321133l1352.57E+001.15E+021.42E+002.45E-041.09E-021.35E-041.42.01.80.01-0.050.5-1.00.1-0.5Preparedby:Date:~~Checkedby:Approvedby:Date:~~Date:~~
REVISIONNo.:2PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTATTACHMENT3CORDBENCHMARKRUNS(Page6of14)OPTION1(OUTPUT)(Page4of7)PAGE:29of83CORD-COREDAMAGEASSESSMENTPROGRAMVERSION1A(5/31/85)RUNTIME:01-29-199313:09:32ENCLOSUREA5-UNIT:PSL1RECORDOFFISSIONPRODUCTRELEASESOURCEIDENTIFICATIONSAMPLENUMBER:002LOCATION:CONTAINMENTATMOSPHEREKR876.06E-02XE131M1.21E-02DecayCorrIsotopeSpecActivity(EnclA4)pCI/ccCalculatedIsotRatio4.97E-019.91E-02FuelPelletInventory0.20.003ACTRatioinGasGap0.0010.001-0.003IdentifiedSourceXE133l131l132l133l1351.22E-011.21E-012.97E-021.33E-031.64E-021.00E+001.00E+002.45E-011.09E-021.35E-011.01.01.42.01.81.01.00.01-0.050.5-1.00.1-0.5Preparedby:Checkedby:Approvedby:Date:~~Date:~~Date:~~
REVISIONNo.:PROCEDURENO.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTATTACHMENT3CORDBENCHMARKRUNS(Page7of14)OPTION1(OUTPUT)(Page6of7)PAGE:30of83CORD-COREDAMAGEASSESSMENTPROGRAMVERSION1A(5/31/85)RUNTIME:01-29-199313:09:35ENCLOSUREA5-UNIT:PSL1RECORDOFFISSIONPRODUCTRELEASESOURCEIDENTIFICATIONSAMPLENUMBER:003LOCATION:CONTAINMENTSUMPKR875.05E-01XE131M1.01E-01DecayCorrIsotopeSpecActivity(EnclA4)pCI/ccCalculatedIsotRatio4.97E+049.91E+03FuelPelletInventory0.20.003ACTRatioinGasGap0.0010.001-0.003IdentiiiedSourceXE133l1311132l133l1351.02E-051.01E+022.48E-011.11E-011.37E-011.00E+001.00E+002.45E-031.09E-031.35E-031.01.01.42.01.81.01.00.01-0.050.5-1.00.1-0.5Preparedby:Checkedby:Approvedby:Date:~jDate:~~Date:~~
REVISIONNo.:2PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTATTACHMENT3CORDBENCHMARKRUNS(Page8of14)OPTION1(OUTPUT)(Page6of7)PAGE:31of83CORD-COREDAMAGEASSESSMENTPROGRAMVERSION1A(5/31/85)RUNTIME:01-29-199313:09:46ENCLOSUREA7-UNIT:PSL1RECORDOFRELEASEQUANTITYKR871.49E+03XE131M2.97E+022.99E+04XE133ReactorCoolantIsotopeSampleNumber,1ContainmentSumpSampleNumber,21.43E+022.86E+012.89E-03ContainAtmosphereSampleNumber,33.58E+037.13E+027.19E+03TotalQuantity5.21E+031.04E+033.71E+04l131l132l1331135CS134RB88TE129TE132SR89BA140LA140LA142PR1442.98E+067.30E+023.26E+044.03E+022.95E+023.29E+051.85E+063.03E+022.95E+022.97E+023.10E+021.08E+044.09E+052.87E+047.03E+013.14E+013.88E+012.84E+013.18E+041.78E+042.92E+012.84E+012.86E+012.99E+011.04E+023.94E+047.16E+031.75E+037.83E+019.68E+027.08E+027.92E+05444E+037.27E+027.09E+027.13E+027.46E+022.59E+039.83E+053.01E+062.55E+033.27E+041.41E+031.03E+031.15E+061.87E+061.06E+031.03E+031.04E+031.09E+031.35E+041.43E+06Preparedby:Checkedby:Approvedby:Date:~~Date:~~Date:~~
REVISIONNO.:PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTATTACHMENT3CORDBENCHMARKRUNS(Page9of14)OPTION1(OUTPUT)(Page7of7)PAGE:32of83CORD-COREDAMAGEASSESSMENTPROGRAMVERSION1A(5/31/85)RUNTIME:01-29-199313:09:50UNIT:PSL1RELEASEOFGASGAPANDFUELPELLETINVENTORYIsotopeKR87GASGAPCorrectedSourceInv1.48E+05%Rel3.52FUELPELLETCorrectedSourceInv3.67E+07%Rel0.01l131l1324.23E+061.36E+06XE131M2.35E+04XE1333.20E+064.431.1671.300.194.03E+058.09E+073.64E+079.61E+070.260.058.280.00l133I135CS134RB88TE129TE132SR89BA140LA140LA142PR1445.02E+063.12E+060.650.051.21E+081.27E+081.94E+055.28E+072.09E+076.52E+071.96E+076.78E+071.01E+081.11E+088.46E+070.030.000.532.188.940.000.010.000.000.011.69Preparedby:Checkedby:Approvedby:Date:~~Date:~~Date:~~
REVISIONNo.:PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTATTACHMENT3CORDBENCHMARKRUNS(Page10of14)OPTION2(INPUT)(Page1of1)CONTAINMENTSAMPLEINFORMATIONPAGE:33of83PERCENTVOLUMEOFH2:.424%CONTAINMENTTEMPATSAMPLING:220FCONTAINMENTPRESATSAMPLING:.5PSIGISSAMPLECORRECTEDTOSTP'7'(Y=YES/N=NO)1:001:302:003:004:00250350260240220F1=DONEF10=QUITRCSSAMPLEINFORMATIONQUANTITYOFHYDROGEN:RCSTEMPATSAMPLING:RCSPRESATSAMPLING:ISSAMPLECORRECTEDTOSTP:REPRESENTATIVEPOWERLEVEL:RCSPRESDURINGUNCOVERY:ESTIMATEOFFUELOVERHEAT:1200cc/kg300F1600PSIGY(Y=YES/N=NO)50%1000PSIA1(1=INITIAL,2=INTERMEDIATE,3=MAJOR)HYDROGENINREACTORVOIDESTIMATEOFVOIDVOLUME:0cuftTEMPERATUREOFLIQUIDATCOOLANTSURFACES:0degFRCSPRESSURE:0psiaISSAMPLECORRECTEDTOSTP?:N(Y=YES/N=NO)
REVISIONNo.:2PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTATTACHMENT3CORDBENCHMARKRUNS(Page11of14)OPTION2(OUTPUT)(Page1of1)PAGE:34of83CORD-COREDAMAGEASSESSMENTPROGRAMVERSION1A(5/31/85)RUNTIME:02-10-199314:09:59SUMMARYOFHYDROGENANALYSIS-UNIT:PSL1HYDROGENINCONTAINMENTATMOSPHERE=10599cuftH2HYDROGENINREACTORCOOLANT=12480cuftH2HYDROGENINREACTORVOIDSPACE=0cuftH2TOTALHYDROGENRELEASED=23079cuftH2TOTALH2BYCONTAINMENTMATERIALOXIDATION=12520cuftH2UPPERLIMITBYHYDROGENMAJOROVERHEAT=1952cuftH2LOWERLIMITBYH2INITIALOVERHEAT=732cuftH2VALUEUSEDFORRADIOLYSISOFWATER=732cuftH2TOTALESTIMATEOFCORECLADOXIDATION=9826.803cuftH22.33%ESTPERCENTOFFUELWITHRUPTUREDCLAD=100.00%UPPEREST%FUELWITHEMBRIMLEDCLADLOWEREST%FUELWITHEMBRITTLEDCLAD=21.05%=905%USETHESERESULTSFOR%RUPTUREDCLADAND%EMBRITlLEDCLADALONGWITHATTACHMENT1TODETERMINEEXTENTOFCLADDAMAGE.Preparedby:Checkedby:Approvedby:Date:~~Date:~~Date:~~
REVISIONNo.:2PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTATTACHMENT3CORDBENCHMARKRUNS(Page12of14)OPTION3(INPUTANDOUTPUT)PAGE:35of83CORD-COREDAMAGEASSESSMENTPROGRAMVERSION1A(5/31/85)UNIT:PSL1RUNTIME:02-10-199314:13:43InputParameters:Temperature(max)=2000degFPressureIT-max=900psiaESTIMATEOFPERCENTRUPTUREDCLADDINGBASEDONCETs=95.68%CAUTIONEstimatespredictedbythemethodologyinthisprocedurearegoodifT-maxremainsbelow1800'Fduringcoreuncoveryandifthecoreremainsuncoveredfor20minutesorlonger.EstimatescouldbeLOWifpressureduringperiodofT-maxdropstolessthan100psiawithinlessthan2minutesofaccidentinitiation,alargebreakisindicated.NOTEThisprocedureyieldsdamageestimatesinNRCCategories2,3and4.Preparedby:Checkedby:Approvedby:Date:j~Date:~~Date:j~
REVISIONNo.:2PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTATTACHMENT3CORDBENCHMARKRUNSPAGE:36of83(Page13of14)OPTION4(INPUT)DOSERATEINFORMATIONENTERDATEANDTIMEOFREACTORSHUTDOWN:DATE:7/18/84TIME:1:00ENTERREPRESENTATIVEPOWERLEVEL:50%MeasuredDoseRateRAD/HR100000TimeofMeasurementDate7/18/84TIITIe3:00500001500040007/18/847/19/847/24/846:001:001:00 REVISIONNO.:PROCEDURENO.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTATTACHMENT3CORDBENCHMARKRUNS(Page14of14)OPTION4(OUTPUT)PAGE:37of83CORD-COREDAMAGEASSESSMENTPROGRAMVERSION1A(5/31/85)RUNTIME:02-10-199314:14:13EDR(R/HR)TPA(HRS)CURVEACURVEBCURVECCURVED0.20E+060.10E+062.05.05.9E+036.1E+042.5E+032.2E+041.6E+057.6E+041.0E+064.4E+05CATEGORY6CATEGORY60.30E+0524.00.80E+04144.05.6E+024.1E+031.0E+026.0E+022.0E+044.5E+031.1E+052.1E+04CATEGORY6CATEGORY6NRCCATEGORYDEFINITIONS:1-NOFUELDAMAGE2-INITIALCLADDINGFAILURE3-INTERMEDIATECLADDINGFAILURE4-MAJORCLADDINGFAILURE5-INITIALFUELPELLETOVERHEATING6-INTERMEDIATEFUELPELLETOVERHEATING7-MAJORFUELPELLETOVERHEATING REVISIONNo.:2PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:38of83ATTACHMENT4PRELIMINARYESTIMATEOFCOREDAMAGEUSINGCOREEXITTHERMOCOUPLECETTEMPERATURES(Page1of5)1.PurposeThepurposeofthissectionistoestimatecoredamagebasedoncoreexitthermocoupletemperaturesuptoaboutthetimewhenthepeakcoretemperaturereachesabout2300'F.Coredamageusingthisindicatorisdescribedbycategories2through4ofthesevenNRCcategoriesinTable2,CladdingDamageCharacteristics,inAttachment1.2.DefinitionsA.CladdingFailureCladdingfailureisdefinedasabreakinthefuelrodcladatleastsufficienttoreleasetheinternalgaspressure.3.PrecautionsandLimitationsA.Theassessmentofcoredamageobtainedbyusingthismethodisonlyanestimate.ThetechniquesemployedinthissectionareonlyaccuratetolocatethecoreconditionwithinthefirstfourofthesevencategoriesofcoredamagedescribedinTable2,CladdingDamageCharacteristics,inAttachment1.Themethodologyisbasedoncoreexittemperaturedata.Otherplantindicationsmaybeavailablewhichcanimproveupontheestimationofcoredamage.B.Therelationshipbetweenthecoreexitthermocoupletemperatureandthecladtemperaturevarieswiththecoreuncoveryscenario.Thisprocedureappliestoslowcoreuncoverybyboiloffofthecoolant.Forothermorerapiduncoveryscenarios,thisprocedurecouldyieldaverylowestimateofthenumberofrupturedrods.Ingeneral,forcoreuncoveryatpressuresbelowabout1200psia,thereishighconfidencethatatleastthepredictedestimateofrodsareactuallyruptured.
REVISIONNO.:PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTATTACHMENT4PRELIMINARYESTIMATEOFCOREDAMAGEUSINGPAGE:39of83COREEXITTHERMOCOUPLECETTEMPERATURES(Page2of5)4.InstructionsA.Obtainthefollowingfromtheinstrumentrecordings:Fromtherecordingofmaximumcoreexitthermocoupletemperatureasafunctionoftime,obtainandrecordonDataSheet4-1,RecordofTemperature,PressureandDamageEstimate,themaximumtemperatureandthetimeitoccurs.Asmanythermocouplesaspossibleshouldbeused,inthiswayequipmentmalfunctionmaybedetectedifathermocouplereadsgreaterthan1650'Forvariesconsiderablyfromitsneighboringthermocouples.FromtherecordingofReactorCoolantSystempressureasafunctionoftime,obtainandrecordonDataSheet4-1,RecordofTemperature,PressureandDamageEstimatethepressureduringtheperiodofmaximumthermocoupletemperature.B.SelectthetemperaturelabeledcurveonFigure4-1,PercentofFuelRadswithRupturedCladvs.MaxCoreExitThermocoupleTemperature,whichcorrespondstoapressureapproximatelyequaltoorgreaterthantheRCSpressure.Entertheabscissa(x-value)atthemaximumCETtemperatureandreadontheordinate(y-value)thepercentofthefuelrodswhichhaverupturedclad.RecordonDataSheet4-1,RecordofTemperature,PressureandDamageEstimate.C.Thisisprobablyalowerlimitestimateofdamage.SomejudgementonthebiasisavailableinReference2.1.2.5.ConclusionsUsethepercentofrodsrupturedfromDataSheet4-1,RecordofTemperature,PressureandDamageEstimate,andthecladdamagecharacteristicsofTable2inAttachment1todeterminetheNRCcategoryofcladdingfailure.ThisprocedureyieldsdamageestimatesinNRCCategories2,3and4.
REVISIONNO.:PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:40of83ATTACHMENT4PRELIMINARYESTIMATEOFCOREDAMAGEUSINGCOREEXITTHERMOCOUPLECETTEMPERATURES(Page3of5)DATASHEET1.RECORDOFTEMPERATUREPRESSUREANDDAMAGEESTIMATE(Page1of2)Step1Recordthefollowingdata:NOTEAsmanythermocouplereadingsaspossibleshouldberecorded.Inthisway,equipmentmalfunctionmaybedetectedifathermocouplereadsgreaterthan1650'Forvariesconsiderablyfromitsneighboringthermocouples.MaximumCoreExitThermocoupleTemperature(SeeInstruction4.Ainthetextforguidelines)oFTimeofMaximumTemperatureReactorCoolantSystemPressureatAboveTimepsiaStep2FromFigure4-1,PercentofFuelRodswithRupturedCladvs.MaxCoreExitThermocoupleTemperature,atmaximumthermocoupletemperatureandatappropriatetemperaturebasedonpressure,readpercentofrupturedrods.0/Step3CommentonprobablebiasofresultsinStep2.(Reference2.1.2,PageE-5).Forexample:a)Asmoothcoreexitthermocouplerecordingandanuncoverydurationof20minutesorlongerareindicatorsforagoodprediction.b)ForalargebreakLOCA,thethermocoupletemperaturemayriserapidlythenquenchwhenthecoreiscovered.Thisprocedurecouldyieldalowestimateforthatsituation.
REVISIONNo.:2PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:41of83ATTACHMENT4PRELIMINARYESTIMATEOFCOREDAMAGEUSINGCOREEXITTHERMOCOUPLECETTEMPERATURES(Page4of5)DATASHEET1.RECORDOFTEMPERATUREPRESSUREANDDAMAGEESTIMATE(Page2of2)Step4NRCCategoryofcladdingfailurefromTable2,CladdingDamageCharacteristics,inAttachment1./Step5EntersummaryinformationintoDataSheet6-2,SummaryWorksheet.MaximumCoreExitThermocoupleTemperatureoFoFOFoFoF REVISIONNO.:2PROCEDURENO.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:42of83ATTACHMENT4PRELIMINARYESTIMATEOFCOREDAMAGEUSINGCOREEXITTHERMOCOUPLECETEMPERATURES(Page5of5)FIGURE4-1~PERCENTOFFUELRODSWITHRUPTUREDCLADVSMAXCOREEXITTHERMOCOUPLETEMPERATUREWhenThePressureIs:Plessthanorequalto100psiaPisbetween100and1200psiaPisbetween1200and1650psiaUseTheCurvesLabeled:1200'1500'1800'10080DI-Q.60004020O0:1200F1500'~1800'01200140016001800200022002400MAXIMUMCOREEXITTHERMOCOUPLETEMPERATURE(F)(PIEPiKPIP-1()FI-RO)
REVISIONNo.:2PROCEDURENo.:PROCEDURETITLE:COREDAMAGEASSESSMENTPAGE:43of83EPIP-11ST.LUCIEPLANTATTACHMENT5PRELIMINARYESTIMATEOFCOREDAMAGEUSINGRADIATIONDOSERATES(Page1of7)PurposeThissectionprovidesthemethodologyforuseunderpost-accidentplantconditionstodeterminethetypeanddegreeofcoredamagewhichmayhaveoccurredbyusingradiationdoseratesmeasuredinsidethecontainmentbuildingusingtheContainmentHighRangeRadiationMonitor(CHRRM).Theradiationdoserateisrelatedtothequantitativereleaseoffissionproductsfromthecoreexpressedasthepercentofthesourceinventoryatthetimeoftheaccident.TheresultingobservationofcoredamageisdescribedbyoneormoreofthesevencategoriesofcoredamageinTable3inAttachment1.2.DefinitionsA.FuelDamageForthepurposeofthissection,fueldamageisdefinedasaprogressivefailureofthematerialboundarytopreventthereleaseofradioactivefissionproductsintotheReactorCoolant,startingwithapenetrationinthezircaloycladding.B.SourceInventoryThesourceinventoryisthetotalquantityoffissionproductsexpressedinCuriesofeachisotopepresentineithersource;thefuelpelletsorthefuelrodgasgap.
REVISIONNO.:PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:44of83ATTACHMENT5PRELIMINARYESTIMATEOFCOREDAMAGEUSINGRADIATIONDOSERATES(Page2of7)3.PrecautionsandLimitationsA.Theassessmentofcoredamageobtainedbyusingthemethodologyinthissectionisonlyanestimate.ThetechniquesemployedinthissectionareonlyaccuratetolocatethecoreconditionwithinoneormoreofthesevencategoriesofcoredamagedescribedinTable3inAttachment1~Theprocedureisbasedonradiationdoserate.Otherplantindicationsmaybeavailablewhichcanimproveupontheestimationofcoredamage.Theseincludesampleradiologicalanalysis,incoretemperatureindicators,andthetotalquantityofhydrogenreleasedfromzirconiumdegradation.Wheneverpossible,theseadditionalindicatorsshouldbefactoredintotheassessment.B.Thissectionreliesuponradiationdoseratemeasurementstakenfromthehighestreadingsoftwohighrangeradiationmonitorslocatedinsidethecontainmentbuildingtodeterminethetotalquantityoffissionproductsreleasedfromthecoreandthereforeavailableforreleasetotheenvironment.Theamountoffissionproductspresentatthelocationofthemonitors'maybechangingrapidlyduetotransientplantconditions.Therefore,multiplemeasurementsshouldbeobtainedwithinaminimumtimeperiodandwhenpossible,understabilizedplantconditions.Samplesobtainedduringrapidlychangingplantconditionsshouldnotbeweighedheavilyintotheassessmentofcoredamage.C.Themethodologyinthissectionislimitedtotheupperboundconditionoffissionproductreleasefromthecoreduetofueloverheat.Simultaneouswithfueloverheat,theremaybelocalizedfuelpelletmeltingwithinthecore.Thetransportofthenon-volatilefissionproductsreleasedduetomeltingisnotknown.ThedoseratesmeasuredunderconditionsoffuelpelletmeltingareanticipatedtoexceedthoseshowninFigure5-1,ContainmentHighRadiationMonitorDoseRatevs.TimeAfterTrip,formajorfueloverheat.However,thisproceduredoesnotattempttoidentifytheextentofanypotentialfuelmelting.
REVISIONNO.:PROCEDURENo.:PROCEDURETITLE:COREDAMAGEASSESSMENTPAGE:45of83EPIP-11ST.LUCIEPLANTATTACHMENT5PRELIMINARYESTIMATEOFCOREDAMAGEUSINGRADIATIONDOSERATES(Page3of7)3.PrecautionsandLimitations(continued)D.Thissectionislimitedtotheinterpretationofthedoseratemeasurementresultingfromamixoffissionproducts.Themethodologycannotaccuratelydistinguishbetweentheconditionsoffuelcladdingfailureandfueloverheatwhentheresultingdoseratesarethesame.Themethodologydoesprovideanupperlimitestimateoftheprogressivecoredamage.Concurrentconditionsofcladdingfailureandoverheatshouldbeanticipatedduetotheradialdistributionofheatgenerationwithinthecore.Distinctionbetweenthetypeofcoredamagerequirestheidentificationofthecharacteristicfissionproducts.Theprocedureforcoredamageassessmentusingradiologicalanalysisoffluidsamplesisrequiredtoexplicitlydistinguishbetweenthecategories.E.Thismethodologyislimitedinapplicabilitytothoseconditionsinwhichthefissionproductinventoryinthecorehashadsufficienttimetoreachequilibrium.Equilibriumfissionproductinventoryisafunctionofreactorpowerandburnup.Baseduponthefissionproductsofconcern,equilibriumconditionsareachievedafterthirtydaysofoperationatconstantpower.Constantpowerisconsideredtoincludechangesofnogreaterthan+10percent.Themethodologymaybeusedfollowingnon-constantperiodsofoperationbyusingengineeringjudgementtoselectthemostrepresentativepowerlevelduringtheperiod.Thismethodmayalsobeusedifthereactorhasproducedpowerforlessthanthirtydays,however,theresultingassessmentofcoredamagewouldbeanunder-predictionoftheactualconditions.
REVISIONNo.:2PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:46of83ATTACHMENT5PRELIMINARYESTIMATEOFCOREDAMAGEUSINGRADIATIONDOSERATES(Page4of7)4.InstructionsA.RecordtheplantindicationsrequiredinDataSheet5-1,ContainmentHighRadiationMonitorvs.TimeAfterTrip.B.PlantPowerCorrectionThemeasuredradiationdoserateinsidethecontainmentbuildingistobecorrectedfortheplantpowerhistory.Acorrectionfactorisusedtoadjustthemeasureddoseratetothecorrespondingvaluehadtheplantbeenoperatingat100percentpower.Tocorrecttheradiationdoserateforthecaseinwhichplantpowerlevelhasremainedconstantforaperiodgreaterthan30days,asimpleratioofthepowermaybeemployed.Thereactorpowerisconsideredtobeconstantifithasnotchangedby+10percentwithinthelastthirtydayspriortothereactortrip.Tocorrecttheradiationdoserateforthecaseinwhichreactorpowerlevelhasnotremainedconstantduringthe30dayspriortothereactorshutdown,engineeringjudgementisusedtodeterminethemostrepresentativepowerlevel.Thefollowingguidelinesshouldbeconsideredinthedetermination.Theaveragepowerduringthe30daytimeperiodisnotnecessarilythemostrepresentativevalueforcorrectiontoequilibriumconditions.Thelastpowerlevelsatwhichthereactoroperatedshouldweighmoreheavilyinthejudgementthantheearlierlevels.Continuedoperationforanextendedperiodshouldweighmoreheavilyinthejudgementthanbrieftransientlevels.Inthecaseinwhichreactorhasproducedpowerforlessthan30days,thisproceduremaybeemployed.However,theestimateofcoredamageobtainedunderthisconditionmaybeanunder-predictionoftheactualcondition.
REVISIONNO.:PROCEDURENo.:PROCEDURETITLE:COREDAMAGEASSESSMENTPAGE:47of83EPIP-11ST.LUCIEPLANTATlACHMENT5PRELIMINARYESTIMATEOFCOREDAMAGEUSINGRADIATIONDOSERATES(Page5of7)4.Instructions(continued)C.Thedecaycorrectionfortheradiationdoseraterequiresthedeterminationofthetimedurationbetweenthereactortripandthemeasurementofthedoserate.Thisisdonesimplyusingthetimeofreactorshutdown(trip)recordedinDataSheet5-1,ContainmentHighRadiationMonitorvs.TimeAfterTrip.5.ConclusionsTheconclusionontheextentofcoredamageismadeusingtheequilibriumdoserate,thedurationofreactorshutdown(hourssincereactortrip),andtheanalyticallydetermineddoseratesprovidedinFigure5-1,ContainmentHighRadiationMonitorvs.TimeAfterTrip.Theequilibriumdoserateisplottedasafunctionoftimefollowingreactorshutdown.EngineeringjudgementisusedtodeterminewhichcategoryofcoredamageshownonFigure5-1,ContainmentHighRadiationMonitorvs.TimeAfterTrip,ismostrepresentativeoftheparticularvaluethathasbeenplotted.Thefollowingcriteriashouldbeconsideredinthedetermination.A.Doseratemeasurementsmayhavebeenrecordedduringperiodsoftransientconditionswithintheplant.Measurementsmadeduringstableplantconditionsshouldweighmoreheavilyintheassessmentofcoredamage.B.Doseratessignificantlyabovethelowerboundforthecategoryofmajorfueloverheatmayindicateconcurrentfuelpelletmelting.Themethodologyinthissectionmaynotbeemployedtoestimatethedegreeoffuelpelletmelting.C.Doserateswithinanycategoryoffueloverheatingmaybeanticipated'oincludeconcurrentfuelcladdingfailure.Themethodologyinthissectionmaynotbeusedtodistinguishtherelativecontributionsofthetwocategoriestothetotaldoserate.Themethodologydoesgivetheestimateofthehighestcategoryofdamage.D.DoseratescorrespondingtothetwocategoriesofmajorcladdingfailureandinitialfueloverheatareobservedtooverlaponFigure5-1,ContainmentHighRadiationMonitorvs.TimeAfterTrip.Theevaluationofotherplantparametersmayberequiredtodistinguishbetweenthem.However,concurrentconditionsmaybeanticipated.
REVISIONNo.:2PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:48of83ATTACHMENT5PRELIMINARYESTIMATEOFCOREDAMAGEUSINGRADIATIONDOSERATES(Page6of7)DATASHEET5-1.CONTAINMENTHIGHRANGERADIATIONMONITORCOREDAMAGEASSESSMENTWORKSHEETHighestRadiationDoseRate(CHRRM)TimeofMeasurement:Date:~~Prior30DaysPowerHistory:TIITIe:Rad/HrPowerPercentDurationDasTimeofReactorTrip:Date:~~Time:EquilibnumDoseRate(RadiHr)MeasuredDoseRate(Radi'Hgx100(RadlHrjReactorPowerLevel(%)RefertoTable3,PercentofSourceInventoryReleasedtoContainment,inAttachment1andFigure5-1,ContainmentHighRadiationMonitorDoseRatevs.TimeAfterTrip,toobtaincategoryofcoredamage.SeeStep5forguidanceinformulatingconclusions.
REVISIONNo.:PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:49Of83ATTACHMENT5PRELIMINARYESTIMATEOFCOREDAMAGEUSINGRADIATIONDOSERATES(Page7of7)FIGURE5-1.CONTAINMENTHIGHRADIATIONMONITORDOSERATEVSTIMEAFTERTRIP100000010001OOOOOKUJ0OZ0CCI-61OOOO5K2CCDQIlIc/pg(Op%pOgCg/(~/(+/yp4/p/gp/w(~(g((egOg,~kgCpd"7y100101001000TIMEPOSTREACTORTRIP,HRS(PIEPAPIP-11'-ROjNOTECategoriesofcoredamageareindicatedinAttachmentI,Tables1,2,and3.Determinationofcoredamageshouldnotbebasedsolelyfromthisgraph.
REVISIONNo.:2PROCEDURENO.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTATTACHMENT6PRELIMINARYESTIMATEOFCOREDAMAGEUSINGPRELIMINARYRADIOISOTOPICDATA(Page1of3)PAGE:50of83CAUTIONCoredamageassessmentusingthereadilyavailableradioisotopicinformationshouldbeusedonlytoobtainageneralestimateoftheextentofcoredegradation.Analysisofradionuclidesamplesisneededtoimproveuponestimateofcoredamage.1~ObtainavailableplantradioisotopicdataandcompleteDataSheet6-1,PreliminaryRadioisotopicdata.
REVISIONNO.:2PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTATTACHMENT6PRELIMINARYESTIMATEOFCOREDAMAGEUSINGPAGE:51of83PRELIMINARYRADIOISOTOPICDATA(Page2of3)DATASHEET6-1.PRELIMINARYRADIOISOTOPICDATACAUTIONTheconcentrationsassumeuniformmix,nodilutionduetoinjection,and1/2houraftershutdown.Inthepresenceofdilution,thisassessmentwillunderestimatecoredamage.STEP1:Obtainpreliminaryradioisotopicdataforthefollowingisotopesasavailable:ActivityJpCi/qmmI-131I-133l-135Cs-134Cs-137Sr-90STEP2:DeterminethecrudecoredamagecategoryfromtheTablebelow.CoreDamageCategory[CoreDamage(GapRelease)orSevereCoreDamage(FuelPelletRelease)]PWRBaselineCoolantConcentrationsVs.CoreDamage(fromReference2.1.6)Nuclidel-131I-133l-135Cs-134Cs-137Sr-90,NormalConcentration(p,Ci/gm)4.5E-021.4E-012.6E-017.1E-039.4E-031.2E-05ConcentrationAfterGapRelease(pCi/gm)6.8E+031.4E+041.2E+041.5E+039.4E+02NotAvail.ConcentrationAfterMeltRelease(pCi/gm)3.4E+056.8E+056.0E+053.0E+041.9E+041.0E+03 REVISIONNO.:2'ROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTATTACHMENT6PRELIMINARYESTIMATEOFCOREDAMAGEUSINGPRELIMINARYRADIOISOTOPICDATA(Page3of3)DATASHEET6-2.SUMMARYWORKSHEETPAGE:52of83RESULTSOFDETAILEDRADIOISOTOPICANALYSIS(ifavailable)FROMATTACHMENT8:PercentCladdingFailurePercentFuelOverheatPercentFuelMeltRESULTSOFAUXILIARYINDICATORS(Attachments4,5,6,7):METHODNRCCATEGORYCHRRMELAPSEDTIMEH,AnalysisCET(Maximum)(R/Hr)(Hrs)(PercentEmbrittled)('F)CharacteristicFissionProductConcentrationI-131(pCi/gm)Cs-134(pCi/gm)ISRXVESSELLEVELBELOWZERO?HASLEVELDROPPEDBELOWZERO?YESNOYESNOSUMMARYOFRESULTS:NOTEComparepercentcladdingfailure,percentfueloverheat,andpercentfuelmeltresultsobtainedfromtheradionuclideanalysistothoseobtainedfromtheauxiliaryindicatorsanalyses.Ifresultsareinagreement,thecoredamageassessmentiscomplete.Iftheresultsarenotinagreement,arecheckofbothanalysesmaybeperformedorcertainindicationsmaybediscountedbasedonengineeringjudgement.Preparedby:Reviewedby:Approvedby:Date:~~Date:~~Date:~~
REVISIONNo.:2PROCEDURENO.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:53of83ATTACHMENT7PRELIMINARYESTIMATEOFCOREDAMAGEUSINGHYDROGEN(Page1of14)1~PurposeThissectionprovidesthemethodologyforuseunderpost-accidentplantconditionstodeterminetheextentoffuelcladdamagewhichmayhaveoccurred.ItutilizeshydrogenmeasuredinsamplesobtainedwiththePost-AccidentSamplingSystem(PASS)andcontainmenthydrogenanalyzers.Themeasuredhydrogenisrelatedtotheamountoffuelcladoxidation.Cladoxidationisinturnrelatedtocladdingfailurewhichisexpressedintermsofthepercentoffuelrodswhicharerupturedandthepercentwhichareembrittled.TheresultingobservationofdamageisdescribedbyoneormoreofthesevencategoriesofcoredamageinTable2,CladdingDamageCharacteristics,inAttachment1.2.DefinitionsA.CladRuptureCladruptureisdefinedasabreakinthefuelrodcladatleastsufficienttoreleasetheinternalgaspressure.B.CladEmbrittlementAttemperaturesabovetherupturetemperature,significantoxidationofthecladoccurs.Iftheoxidationexceedstheembrittlementthreshold,fragmentationofembrittledcladmaysubsequentlyoccurfromthermalshockorhydraulicpressureforcessuchthatthestructureofthefuelassemblyisdestroyedandsubstantialfuelpelletfragmentsarereleasedtothecoolant.3.PrecautionsandLimitationsA.Theassessmentofcoredamageobtainedbyusingthismethodologyisonlyanestimate.ThetechniquesemployedinthissectionareonlyaccuratetolocatethecoreconditionwithinoneormoreofthesevencategoriesofcoredamageinTable2,CladdingDamageCharacteristics,inAttachment1~B.ThemethodologyinthissectionisapplicableunderconditionsforwhichtherearenovoidsmeasurablebytheReactorVesselLevelMonitoringSystem(RVLMS).
REVISIONNo.:PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:54of83ATTACHMENT7PRELIMINARYESTIMATEOFCOREDAMAGEUSINGHYDROGEN(Page2of14)4.InstructionsA.CoreUncoveryConditions:RecordthecoreconditionsoverthetimeperiodofcoreuncoveryonDataSheet7-1,CoreUncoveryConditions.B.SamplingConditionsandMeasuredHydrogen1~RecordtheconditionsincontainmentandtheRCSatthetimethehydrogensamplesareobtained.'.EnterontheworksheetofDataSheet7-2,SamplingConditionsandMeasuredHydrogen.3.RecordtheresultsofhydrogensamplingandanalysisontheworksheetofDataSheet7-2,SamplingConditionsandMeasuredHydrogen.4.Followtheinstructionstoobtainthetotalamountofhydrogenmeasuredinunitsofcubicfeetofhydrogenatstandardtemperatureandpressure.C.HydrogenGeneratedinContainmentNOTEDataSheet7-3,HydrogenGeneratedinContainment,utilizesmeasureddataforthecontainmenttemperatureasafunctionoftimeuptothesamplingtimeandaplantspecificcurveoftherateofproductionasafunctionofcontainmenttemperatureinFigure7-2,HydrogenProductionRatefromAluminumandZincvs.Temperature.1~DataSheet7-3,HydrogenGeneratedinContainment,isaworksheetforcalculatingtheamountofhydrogengeneratedbyoxidationofmaterialswithinthecontainment.2.RecordthedatarequiredonDataSheet7-3,HydrogenGeneratedinContainment.3.CompletetheindicatedcalculationstoobtainthecubicfeetofhydrogenatSTPgeneratedbycontainmentmaterialsoxidation.
REVISIONNo.:2PROCEDURENo.:PROCEDURETITLE:COREDAMAGEASSESSMENTPAGE:55of83EPIP-11ST.LUCIEPLANTATTACHMENT7PRELIMINARYESTIMATEOFCOREDAMAGEUSINGHYDROGEN(Page3of14)4.Instructions(continued)D.HydrogenGeneratedbyRadiolysisNOTE1.Thehydrogengeneratedbyradiolysisisafunctionofoperatingpoweranddecaytime.2.Forthecaseinwhichtheoperatingpowerisconstantorhasnotchangedbymorethan+10percentforaperiodgreaterthan30days,thatpowerisused.3.Forthecaseinwhichthepowerhasnotremainedconstantduringthe30dayspriortothereactortrip,Engineeringjudgementisusedtodeterminethemostrepresentativepowerlevel~1.Thefollowingguidelinesshouldbeconsideredinthedetermination:a.Theaveragepowerduringthe30daytimeperiodisNOTnecessarilythemostrepresentativevaluefordeterminingradiolysisbyfissionproducts.b.Thelastpowerlevelsatwhichthereactoroperatedshouldweighmoreheavilyinthejudgementthantheearlierlevels.c.Continuedoperationforanextendedperiodshouldweighmoreheavilyinthejudgementthanbrieftransientlevels.d.Forthecaseinwhichthereactorhasproducedpowerforlessthan30days,thismethodologymaybeemployed.However,theestimateofhydrogenfromradiolysiswillbetoohighandthecalculatedhydrogenbycoreoxidationwillbetoolow.Hence,anunder-predictionofcoredamagemayresult.2.RecordthedatarequiredontheworksheetofDataSheet7-4,HydrogenGeneratedbyRadiolysis.
REVISIONNo.:2PROCEDURENo.:PROCEDURETITLE:COREDAMAGEASSESSMENTPAGE:56of83EPIP-11ST.LUCIEPLANTATTACHMENT7PRELIMINARYESTIMATEOFCOREDAMAGEUSINGHYDROGEN(Page4of14)4.Instructions(continued)E.CoreDamageAssessment,HydrogenEntertheamountsofhydrogenfromSteps4.B,CandDontheworksheetofDataSheet7-5,CoreDamageAssessmentfromHydrogenMeasurement.2.SubtracttheamountsinSteps4.CandDfrom4.Basindicatedontheworksheettoyieldthecubicfeetofhydrogengeneratedbycorecladoxidation.3.CompletetheinstructionsofDataSheet7-5,CoreDamageAssessmentfromHydrogenMeasurement,todeterminethepercentageoffuelrodswithrupturedcladandthepercentageoffuelrodswithembrittledclad.F.Conclusion1.Theconclusiononcoredamageismadeusingthetworesultsfromabove.Theseare:a.Percentageoffuelrodswithrupturedclad.b.Percentageoffuelrodswithembrittledorstructurallyfailedcladding.2.KnowledgeablejudgementisusedtocomparetheabovetworesultstothedefinitionsofthesevenNRCcategoriesoffueldamagefoundinTable2,CladdingDamageCharacteristics,inAttachment1~CoredamagedoesNOTtakeplaceuniformly.Therefore,whenevaluatingdamageusingtheseresults,Table2,CladdingDamageCharacteristics,inAttachment1mayyieldacombinationofcategoriesofdamagewhichexistsimultaneously.
REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:COREDAMAGEASSESSMENTPAGE:57of83EPIP-11ST.LUCIEPLANTATTACHMENT7PRELIMINARYESTIMATEOFCOREDAMAGEUSINGHYDROGEN(Page5of14)DATASHEET7-'I.COREUNCOVERYCONDITIONSTimeperiodofcoreuncovery.Completethefollowingtableusingrecordedinstrumentdata.InstrumentReactorVesselLevelMonitoringSystemEstimatedCoreuncoveTimeLowerLimitElevationUncovers(coreuncovery)TlrneEstimatedCoreRecoveTimeLowerLimitElevationRecoversTimeCoreExitThermocoupleTemperatureStartofContinuousRiseorExceed660'FTimeTemperatureRapidTemperatureDroptoSaturationTlfneTemperatureCoreExitThermocoupieStartofSuperheatSaturationMarginTimeReturntoSaturationTlrneInterpretabovedatatoobtainbestestimatefortimeperiodofcoreuncoveryandobtainpressurizerpressurerangeduringthatperiod.Thesuperheatderivedfromthethermocoupletemperatureandcorrespondingsystempressureisconsideredasthebestindicatorforcoreuncoveryduringboiloffandshouldbeused,butshouldbecomparedwiththeotherindicatorstohelpidentifypossibleanomalies.CoreUncoveCoreRecoveTlrnePressureEstimatevesselinletflowratesduringcoreuncoveryheatupperiod,uptoapproximatelythetimeofpeakcoreexitthermocoupletemperature.Netinletflowindicatesthatthemethodologymayhaveadditionalbiaswhichunder-predictscladdamage.ChargingFlowRateLetdownFlowRateHPSIFlowRateLPSIFlowRateOtherInletFlowsNetinletflow=ChargingFlow+HighPressureSafetyInjection(HPSI)andLowPressureSafetyInjection(LPSI)flow+otherinletflow-LetdownFlow.
REVISIONNo.:PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:58of83ATTACHMENT7PRELIMINARYESTIMATEOFCOREDAMAGEUSINGHYDROGEN(Page6of14)DATASHEET7-2.SAMPLINGCONDITIONSANDMEASUREDHYDROGENObtaintheRCSandcontainmentconditionsatthetimeofsamplingforhydrogen.ReactorCoolantSstemContainmentSamplingTimePressureTemperature,T,,PslgoFSamplingTimeAtmosphericPressureAtmosphericTemperaturePslgQFReactorVesselCoolantLevelHasHydrogenRecombinerpercentOperated?Yes/NoPressurizerLevelpercentDoesPressureorTemperatureHistoryIndicateaHydrogenBurn?Yes/NoHydrogenSampleDataReductionCont.Sample(Vol.percent/100)xCont.Vol.(ft.')x(32+460)/(NormalTemp.+460)=ft',atSTPx2.5E6x492/RCSSample(cc/kgatSTP)xRCSVol.*(ft')xDensityRatiopQp~(FigureC-2.A.1)/1000=ft3H~atSTP/1000=Total=Cont.Sample(ft')+RCSSample=AlsorecordtotalonDataSheet7-5,CoreAssessmentfromHydrogenMeasurement.*RCSvolumeis:PSL1=10,401ft'SL2=10,198ft REVISIONNO.:2PROCEDURENO.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:59of83ATTACHMENT7PRELIMINARYESTIMATEOFCOREDAMAGEUSINGHYDROGEN(Page7of14)DATASHEET7-3.HYDROGENGENERATEDINCONTAINMENTSTEP2.A.4.CRecordthecontainmenttemperatureatselectedtimeintervalsandcalculatethehydrogengeneratedbyoxidationofcontainmentmaterialsutilizingtheplant-specificproductionratesfromFigure7-2.1TimeatStartofIntervalsAccidentStarts2ContainmentTemperature('F)34IntervalAvg.ContainmentDuration(Hr)Temp.DuringInterval('F)56H,Prod.RateH,Produced(ft'lhr)(Col.3)X(Col.5)Fig.7-2SampleTimeLongTermHydrogenProductioninContainmentTotal(SummationofColumn6)Shorttermrapidhydrogenproductionbycontainmentaluminum,2.277ft'orPSL1and5,235ft'orPSL2(Reference2.1.2,Table4.3)+TotalHydrogenProductioninContainmentSCFSCFSCFRecordtotalonDataSheet7-5,CoreDamageAssessmentfromHydrogenMeasurement,also.ItemsinColumns1and2areinputplantdata.IntervalDurationisthelinedifferencebetweenconsecutivetemperaturereadings.
REVISIONNO.:PROCEDURENO.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:60of83ATTACHMENT7PRELIMINARYESTIMATEOFCOREDAMAGEUSINGHYDROGEN(Page8of14)DATASHEET7-4.HYDROGENGENERATEDBYRADIOLYSISRecordthefollowingdataandutilizethecurvesofFigure7-3,SpecificRadiolyticHydrogenProductionvs.DecayTime,todeterminethehydrogengeneratedbyradiolysis.Prior30dayspowerhistoryPowerPercentDurationDasNote:Nocalculationisrequiredtodeterminepowerlevel,guidanceonjudgementisprovidedinStep4.D.EstimatedPowerLevelbasedonapowerhistory:0eratinPowerMwt:Powertouseinevaluatinglongtermhydrogenproductionbyradiolysis=Fullpower,Mwt)xPowerLevel100(FullPower:PSL1,PSL2=2700Mwt)T,=TimeofReactorTripTimeT,=TimeSampleTakenDecayTime(TimeInterval,T,-T,)HoursEnterabscissa(x-value)onFigure7-3,SpecificRadiolyticHydrogenProductionvs.DecayTime,withabovedecayandreadtwovaluesofhydrogenproducedbyradiolysis,onefromeachcurve,incubicfeetofhydrogenatSTPperMwtoperatingpower.Multiplybyabovepowerandrecordasfollows:LimitCurveHydrogenProducedSCF/Mwt.Fiure7-3OperatingTotalHydrogenupperLowerUsingresultsfromRadiologicalAnalysisofSamples,estimatewhichresultsshouldbeused;upperlimitformajorfueloverheat,lowerlimitforinitialfueloverheat,orappropriateestimatebetweenthetwocurvesforintermediatefueloverheat.CirclecorrespondingvalueofhydrogenaboveandalsorecordonDataSheet7-5,CoreDamageAssessmentfromHydrogenMeasurement.
REVISIONNO.:2PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:61of83ATTACHMENT7PRELIMINARYESTIMATEOFCOREDAMAGEUSINGHYDROGEN(Page9of14)DATASHEET7-5.COREDAMAGEASSESSMENTFROMHYDROGENMEASUREMENT(SUMMARY)A.HydrogenMeasured,fromDataSheet7-2,SamplingConditionsandMeasuredHydrogen.SCFB.HydrogenProducedinContainment,fromDataSheet7-3,HydrogenGeneratedinContainment.SCFC.HydrogenProducedbyRadiolysis,fromDataSheet7-4,HydrogenGeneratedbyRadiolysis.SCFSubtractBandCfromAtogetHydrogenProducedbyCoreCladOxidationSCFDivideby(4210forPSL1)or(4640forPSL2).ThesevaluesrepresentthequantityinSCFofhydrogenproducedperpercentofZirconiumoxidizedforSt.LucieUnit1andUnit2,respectively.(Reference2.1.2,Table4.2).=%CoreCladOxidizedEnterabscissa(x-value)onFigure7-4,PercentofFuelRodswithRupturedCladvs.PercentageofCoreCladOxidation,with"PercentOxidationofCoreClad"andreadordinatefromtemperaturelabeledcurvecorrespondingtothepressureduringcoreuncoveryasgivenonDataSheet7-1,CoreUncoveryConditions.RecordherePercentofFuelRodswithRupturedClad.Enterabscissa(x-value)onFigure7-5,OxidationEmbrittlementvs.TotalCoreOxidation,withabove"PercentOxidationofCoreClad"andreadrangeofvaluesonordinate(y-value).Recordhere.PercentofFuelRodsEmbrittled:Range-Upper-Lower0/FromTable2,CladdingDamageCharacteristics,inAttachment1,selectthecorecladdamagecategoriesbasedontheabovepercentagesofrodsembrittled(damaged)andenterinDataSheet6-2,SummaryWorksheet.Notethatthisassessmentwillunder-predictfueldamageifhydrogenrecombinershaveoperatedorHydrogenbumhasoccurred.
REVISIONNO.:PROCEDURENO.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:62Of83ATTACHMENT7PRELIMINARYESTIMATEOFCOREDAMAGEUSINGHYDROGEN(Page10of14)FIGURE7-1.RATIOOFH20DENSITYTOH20DENSITYATSTPvsTEMPERATURE700600500400KDl~K300I-2001000.5DENSITYRATIO,ACTUAL/STP(PIFPiKPIP.11'.RO)
REVISIONNO.:2PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:63of83ATTACHMENT7PRELIMINARYESTIMATEOFCOREDAMAGEUSINGHYDROGEN(Page11of14)FIGURE7-2.HYDROGENPRODUCTIONRATEFROMALUMINUMANDZINCvsTEMPERATURE800070006000Z05000DO0KK(gu4000OO'(8CIz3000I~KPSL2PSL120001000100120140160180200220240260280300CONTAINMENTTEMPERATURE('F)(PiKPiKPIP-11~Ra)
REVISIONNO.:2PROCEDURENO.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:64of83ATTACHMENT7PRELIMINARYESTIMATEOFCOREDAMAGEUSINGHYDROGEN(Page12of14)FIGURE7-3.SPECIFICRADIOLYTICHYDROGENPRODUCTIONVSDECAYTIMEMAJORFUELOVERHEATZ0OI-DCI0CC10ill(g~0W0gh~Z00gM0CIKOOUJ(0INTERMEDIATEFUELOVERHEATINITIALFUELOVERHEAT00100200300400500600700800DECAYTIME,HOURS(PiKPIEPIP-111'.RO)
REVISIONNO.:2PROCEDURENO.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:65of83ATTACHMENT7PRELIMINARYESTIMATEOFCOREDAMAGEUSINGHYDROGEN(Page13of14)FIGURE7-4.PERCENTOFFUELRODSWITHRUPTUREDCLADVS.PERCENTAGEOFCORECLADOXIDATIONWhenThePressureIs:Plessthanorequalto100psiaPisbetween100and1200psiaPisbetween1200and1650psiaUseTheCurvesLabeled:1200'1500F1800F100Cl80KQ.CC60I-CI040(9201200'1500'800'0.51.5PERCENTOXIDATIONOFCORECLAD2.5(PIEPIEPIP-11/Fd-RO)
REVISIONNO.:2PROCEDURENO.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:66of83ATTACHMENT7PRELIMINARYESTIMATEOFCOREDAMAGEUSINGHYDROGEN(Page14of14)FIGURE7-5.OXIDATIONEMBRITTLEMENTVSTOTALCOREOXIDATIONST.LUCIEUNITS1&2100I-IlJIlJKmZ0l~90XO0zI-(IJCI00llJD0I-OKllJ80604020UPPERRANGELOWERRANGE0020406080100PERCENTOXIDATIONOFCORECLAD(PiKPIEPIP-11/Fe.RO)/R2 REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:COREDAMAGEASSESSMENTPAGE:67of83EPIP-11ST.LUCIEPLANTATTACHMENT8DETAILEDRADIOLOGICALANALYSIS(Page1of17)PurposeThissectionprovidesamethodunderpost-accidentplantconditionstodeterminethetypeanddegreeofreactorcoredamagewhichmayhaveoccurredbyusingfissionproductisotopesmeasuredinsamplesobtainedfromthePost-AccidentSamplingSystem(PASS).Therearethreefactorsconsideredinthissectionwhicharerelatedtothespecificactivityofthesamples.Theseare(1)theidentityofthoseisotopeswhicharereleasedfromthecore,(2)therespectiveratiosofthespecificactivityofthoseisotopes,and(3)thepercentofthesourceinventoryatthetimeoftheaccidentwhichisobservedtobepresentinthesamples.TheresultingobservationofcoredamageisdescribedbyoneormoreofthetencategoriesoffueldamageinTable1inAttachment1.2.DefinitionsA.FuelDamageForthepurposeofthismethodology,fueldamageisdefinedasaprogressivefailureofthematerialboundarytopreventthereleaseofradioactivefissionproductsintotheReactorCoolant,startingwithapenetrationinthezircaloycladding.B.SourceInventoryThesourceinventoryisthetotalquantityoffissionproductsexpressedinCuriesofeachisotopepresentineithersource,thefuelpelletsorthefuelrodgasgap.3.PrecautionsandLimitationsA.Themethodologyinthissectionreliesuponsamplestakenfrommultiplelocationsinsidethecontainmentbuildingtodeterminethetotalquantityoffissionproductsavailableforreleasetotheenvironment.Theamountoffissionproductspresentateachsamplelocationmaybechangingrapidlyduetotransientplantconditions.Therefore,itisrecommendedthatthesamplesshouldbeobtainedwithinaminimumtimeperiodandifpossible,understabilizedplantconditions.Samplesobtainedduringrapidlychangingplantconditionsshouldnotbeweighedheavilyintotheassessmentofcoredamage.
REVISIONNo.:PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTATTACHMENT8DETAILEDRADIOLOGICALANALYSIS(Page2of17)PAGE:68of833.PrecautionsandLimitations(continued)B.Anumberoffactorsinfluencethereliabilityofthechemistrysamplesuponwhichthissectionisbased.Reliabilityisinfluencedbytheabilitytoobtainrepresentativesamplesduetoincompletemixingofthefluids,andequipmentlimitations.Theaccuracyachievedintheradiologicalanalysesarealsoinfluencedbyanumberoffactors.Theequipmentemployedintheanalysismaybesubjectedtohighlevelsofradiationexposureoverextendedperiodsoftime.Chemistsarerecommendedtoexerciseconsiderablecautiontominimizethespreadofradioactivematerials.Sampleshavethepotentialofbeingcontaminatedbynumeroussources.Coolingorreactionsmaytakeplaceinthelongsamplelines.Therefore,theresultsobtainedmaynotberepresentativeofplantconditions.Tominimizetheseeffects,multiplesamplesshouldbeobtainedoveranextendedtimeperiodfromeachlocation.4.InstructionsA.ObtainandrecordtheplantindicationsandsourceofindicationrequestedonDataSheet8-1,InputParameters.Becauseoftransientconditions,thevaluesshouldberecordedascloseaspossibletothetimeatwhichtheradiologicalsamplesareobtained.1.RequestsamplingatthelocationsrecommendedforcoredamageassessmentusingtheguidelinesprovidedinTable8-1,SampleLocationsRecommendedforCoreDamageAssessment.2.Obtainresultsofsamplingandanalysisandrecordtherequiredsampledata,correctedtoStandardTemperatureandPressure(STP),andtimeofsamplecollectiononDataSheet8-1,InputParameters.AlloftheisotopeslistedinDataSheet8-1,InputParameters,maynotbeobservedinthesample.B.CorrectthesamplespecificactivityatSTPfordecaybacktothetimeofreactortripfollowingtheinstructiononDataSheet8-2,RecordofMeasuredSpecificActivity(DecayCorrected).
REVISIONNO.:PROCEDURENO.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTATTACHMENT8DETAILEDRADIOLOGICALANALYSIS(Page3of17)PAGE:69of834.Instructions(continued)C.IdentificationoftheFissionProductReleaseSource1.CalculatetheratiosforeachnoblegasandiodineisotopeusingthespecificactivitiesobtainedinStep4.RecordtheseratiosonDataSheet8-3,RecordofFissionProductReleaseSourceIdentification.2.Determinethesourceofrelease(gasgaporfuelpellet)bycomparingtheresultsobtainedinStep4.C.1tothepredictedratiosprovidedinDataSheet8-3,RecordofFissionProductReleaseSourceIdentification.Anaccuratecomparisonisnotanticipated.Withintheaccuracyofthismethodology,itisappropriatetoselectasthesourceofrelease,thatratiowhichisclosesttothevalueobtainedinStep4.C.1.D.QuantitativeReleaseAssessment1.CalculatethetotalquantityoffissionproductsfoundintheRCSpertheinstructionsonDataSheet8-4,QuantitativeReleaseAssessmentWorksheet.2.CalculatethequantityoffissionproductsfoundinthecontainmentbuildingsumppertheinstructionsonDataSheet8-4,QuantitativeReleaseAssessmentWorksheet.3.CalculatethequantityoffissionproductsfoundinthecontainmentbuildingatmospherepertheinstructionsonDataSheet8-4,QuantitativeReleaseAssessmentWorksheet.4.Thetotalquantityoffissionproductsavailableforreleasetotheenvironmentisequaltothesumofthevaluesobtainedfromeachsamplelocation(liquidandgas)asrecordedonDataSheet8-5,RecordofCoreReleaseInventory.
REVISIONNO.:2PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTATTACHMENT8DETAILEDRADIOLOGICALANALYSIS(Page4of17)PAGE:70of834.Instructions(continued)E.PlantPowerCorrectionThequantitativereleaseofthefissionproductsisexpressedasthepercentofthesourceinventoryatthetimeoftheaccident.Theequilibriumsourceinventoriesaretobecorrectedforplantpowerhistory.1.SteadyStatePowerCorrectionTocorrectthesourceinventoryforthecaseinwhichplantpowerlevelhasremainedconstantforaperiodgreaterthanfourradioactivehalf-lives,completeDataSheet8-6,RecordofTransientPowerCorrection.Half-livesareincludedinDataSheet8-2,RecordofMeasuredSpecificActivity(DecayCorrected).2.TransientPowerCorrectionTocorrectthesourceinventoryforthecaseinwhichplantpowerlevelhasnotremainedconstantpriortoreactortrip,followtheinstructionsofDataSheet8-7,RecordofTransientPowerCorrection,wherethetransientPowerCorrectionFactorisdefinedas:PgFgP(1e-xt>)eAlj100WherePI=SteadyreactorpowerintimeperiodjtI=durationoftimeperiodj(sec)t>=timefromreactortriptoendoftimeperiodj(sec)X,=isotopedecayconstantfromDataSheet8-2,RecordofMeasuredSpecificActivity(DecayCorrected)
REVISIONNo.:PROCEDURENO.:PROCEDURETITLE:COREDAMAGEASSESSMENTPAGE:71of83EPIP-11ST.LUCIEPLANTATTACHMENT8DETAILEDRADIOLOGICALANALYSIS(Page5of17)4.Instructions(continued)F.ComparisonofMeasuredDatawithSourceInventoryThetotalquantityoffissionproductsavailableforreleasetotheenvironmentobtainedinStep4.D.4,DataSheet8-5,RecordofCoreReleaseInventory,iscomparedtothesourceinventorycorrectedforplantpowerhistoryobtainedinStep4.E,DataSheet8-6,RecordofSteadyStatePowerCorrection,or8-7,RecordofTransientPowerCorrection.Thiscomparisonismadebydividingthetotalquantityavailableforreleasebythepowercorrectedsourceinventory.RecordthispercentageonDataSheet8-8,RecordofPercentRelease.G.ConclusionTheconclusiononcoredamageismadeusingthethreeparametersdevelopedabove.Theseare:1.Identificationofthefissionproductisotopeswhichmostcharacterizeagivensample,Step4.A,DataSheet8-1,InputParameters.2.Identificationofthesourceoftherelease,Step4.C,DataSheet8-3,RecordofFissionProductReleaseSourceIdentification.3.Quantityoffissionproductavailableforreleasetotheenvironmentexpressedasapercentofsourceinventory,Step4.F,DataSheet8-8,RecordofPercentRelease.KnowledgeablejudgementisusedtocomparetheabovethreeparameterstothedefinitionsofthetenNRCCategoriesofFuelDamagefoundinTable1,CharacteristicIsotopes,inAttachment1.Coredamageisnotanticipatedtotakeplaceuniformly.Therefore,whenevaluatingthethreeparameterslistedabove,themethodologyinthissectionisanticipatedtoyieldacombinationofoneormoreofthetencategoriesdefinedinTable1,CharacteristicIsotopes,inAttachment1.Thesecategorieswillexistsimultaneously.
REVISIONNO.:PROCEDURENo.:PROCEDURETITLE:COREDAMAGEASSESSMENTPAGE:72of83EPIP-11ST.LUCIEPLANTATTACHMENT8DETAILEDRADIOLOGICALANALYSIS(Page6of17)TABLE8-I.SAMPLELOCATIONSRECOMMENDEDFORCOREDAMAGEASSESSMENT(ReferenceStep4.1.A)AccidentScenarioKnownSmallBreakLOCA,ReactorPowergreaterthan1percentSmallBreakLOCA,ReactorPowerlessthan1percentSmallSteamLineBreakLargeBreakLOCA,ReactorPowergreaterthan1percentLargeBreakLOCA,ReactorPowerlessthan1percentLargeSteamLineBreakSteamGeneratorTubeRuptureRCSHotLegYesYesYesYesYesYesRCSPressurizerYesYesYesContainmentSump(')YesYesContainmentAtmosphereYesYesYesYesShutdownCoolingSystemYesYesYesYesSteamGenerato(SecondaryYes*Availableonlyonrecirculation REVISIONNo.:2PROCEDURENO.:PROCEDURETITLE:COREDAMAGEASSESSMENTPAGE:73of83EPIP-11ST.LUCIEPLANTATTACHMENT8DETAILEDRADIOLOGICALANALYSIS(Page7of17)DATASHEET8-'I.INPUTPARAMETERS(Page1of2)Unit:ReactorCoolantSystem:PressureTemperature(T,,)PSIGOFReactorVesselLevelShows:FullVoidBelowRecorder(CircleOne)PressurizerLevelContainmentBuilding:PercentAtmospherePressureAtmosphereTemperaturePSIGoFPrior30DaysPowerHistory:PowerPercentDurationDasEstimatedAveragePowerLevelDuringLast30DaysEstimatedAveragePowerLevelDuringLast4DaysPercentPercentTimeofReactorTrip:Date:~~Time:ChangeinvolumeofRWT:ChangeinvolumeofBAMT:gal.Time:gal.Time:SITinjected(yes/no):
REVISIONNo.:PROCEDURENO.:EPIP-11Unit:PROCEDURETITLE.'OREDAMAGEASSESSMENTST.LUCIEPLANTATTACHMENT8DETAILEDRADIOLOGICALANALYSIS(Page8of17)DATASHEET8-1~INPUTPARAMETERS(Page2of2)RADIONUCLIDEDATA(ReferenceStep4)SampleNumber:PAGE:74of83SampleLocation(RCS,Sump,Containment):TimeofSampleCollection:IsotopeKr87Xe-131mXe-133l-131I-132l-1331-135~cs-134.Rb-ss'~yTe-129~IjMTe-132Sr-89Ba-140La-140La-142Pr-144MeasuredSpecificActivityatSTPA(pCI/cc)NOTE:N/Iifnotidentified.
REVISIONNO.:PROCEDURENO.:EPIP-I1PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:75of83ATTACHMENT8DETAILEDRADIOLOGICALANALYSIS(Page9of17)DATASHEET8-2.RECORDOFMEASUREDSPECIFICACTIVITYDECAYCORRECTED(ReferenceStep4.B)Unit:TimeofReactor(Rx)Trip,DataSheet8-1,InputParameters(Page1of2):SampleNumber:SampleLocation(RCS,Sump,Containment):TimeofSampleCollection:ElapsedTime,t(RxTriptoSample):sec.IsotopeKr87Xe-131mXe133I-131I-132I-133I-135Cs-134Rb-88Te-129Te-132Sr-89ea-140La-140La-142Pr-144HalfLife76m12d5.4d8d2h21h6.8h2yf70m78h52.7d12.8d40h90m17.4mDecayConstantX(1/sec)1.5E-46.7E-71.5E-69.9E-78.4E-59.3E-62.9E-51.1E-86.5EA1.7EA2.5E-61.6E-76.3E-74.8E-61.2E-46.7E-4MeasuredSpecificActivityISTPA(pCi/cc)DecayCorrectedSpecificActivity,Ao(pCi/cc)A,=Where:AandXareasabove,andt=timeperiodinsecondsfromreactortriptosamplecollected.NOTE:N/Iifnotidentified.
REVISIONNO.:PROCEDURENO.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTATTACHMENT8DETAILEDRADIOLOGICALANALYSIS(Page10of17)DATASHEET8-3.RECORDOFFISSIONPRODUCTRELEASESOURCEIDENTIFICATION(ReferenceStep4.C.1)PAGE:76of83Unit:SampleNumber:Location:IsotopeKr87Xe131mDecayCorrectedSpecificActivityDataSheet8-2,Ci/ccCalculatedActivityRatioIsotopeinFuelPelletRatio*InventoIy**0.20.003ActivityRatioIdentifiedSourceinGasGap(GasGaporInventory*'uelPellet)lessthan0.0010.001-0.003Xe133I131I132I133I1351.01.01.01.01.42.01.81.01.00.01-0.050.5-1.00.1-0.5N/AN/ADecayCorrectedNobleGasSpecificActivityNobleGasRatioDecayCorrectedXe-133SpecificActivityDecayCorrectediodineIsotopeSpecificActivityiodineRatioDecayCorrectedl-131SpecificActivity**Table3.3ofReference2.1.2 REVISIONNo.:2PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:77of83ATTACHMENT8DETAILEDRADIOLOGICALANALYSIS(Page11of17)DATASHEET8-4.QUANTITATIVERELEASEASSESSMENTWORKSHEET(ReferenceStep4.D)(Page1of2)RCSACTIVITY(ATqcs)RCST,g'F(AtorNearTimeofSample)VesselLevelIndication(Full,Void,BelowRecorder):IFFULLORVOID,performthefollowingcalculationforeachisotopemeasured.IFBELOWRECORDER,usetheContainmentSumpcalculationbelowinstead.(ATques)(C)Ao(pCI/CC)xRCSVolumex10E06(Cl/pCI)Where:Ao=decaycorrectedspecificactivityofRCSsample(DataSheet8-2,RecordofMeasuredSpecificActivity(DecayCorrected))RCSvolume=WaterVolumexDensityRatioatRCSTavg(Figure7-1,RatioofH,ODensityatSTPvs.Temperature).PSL1watervolumeis2.945E+08ccandPSL2watervolumeis2.889E+08cc.EnterresultsinDataSheet8-5,RecordofCoreReleaseInventory(AT<<,)SUMPACTIVITY(AT~~p)Determinesump'watervolumebyaddingthefollowing:RCSVolumePSL1gal58,300PSL257,400SITInjectedVolume=+gal34,04946,564BAMTInjectedVolume=+gal(DataSheetC-3.A)RWTVolumeChange=+gal(DataSheetC-3.A)V,=TotalSumpVolume=galx3785cc/gal=CC(ATzp~p)Ao(p,Ci/cc)xV,x1.0E-06(Ci/p,Ci)WhereA,=decaycorrectedspecificactivityofSUMPsample(DataSheet8-2,RecordofMeasuredSpecificActivity(DecayCorrected))EnterresultsinDataSheet8-5,RecordofCoreReleaseInventory(AT,).
REVISIONNO.:PROCEDURENO.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:78of83ATTACHMENT8DETAILEDRADIOLOGICALANALYSIS(Page12of17)DATASHEET8-4.QUANTITATIVERELEASEASSESSMENTWORKSHEET(ReferenceStep3.D.4)(Page2of2)CONTAINMENTACTIVITY(AT,I)CalculateContainmentVolumeincc,includingpressureandtemperaturecorrections.V,=ContainmentVo/ume(cc)=7.096E10x'T1+460(P1+14.7)(32+460)Where:P1=Containmentpressureinpsig(DataSheet8-1,InputParameters)T1=Containmenttemperaturein'F(DataSheet8-1,InputParameters)(AT~<<)=Ao(p,Ci/CC)xV,x1.0E-6(Ci/pCi)Where:Ao=Decaycorrectedspecificactivityforcontainmentsample(DataSheet8-2,RecordofMeasuredSpecificActivity(DecayCorrected))EnterresultsinDataSheet8-5,RecordofCoreReleaseInventory(AT<<).
REVISIONNo.:2PROCEDURENO.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:79of83Unit:ATTACHMENT8DETAILEDRADIOLOGICALANALYSIS(Page13of17)DATASHEET8-5.RECORDOFCORERELEASEINVENTORY(ReferenceStep4.DA)IsotopeKr87Xe131mXe133I131I132I133I135Cs134Rb88Te129Te132Sr89Ba140La.I40La142Pr144ReactorCoolantSampleATcs(C')ContainmentSumpSample+A7p(Ci)ContainmentAtmosphereSample+AT,mnI(Ci)=TotalQuantity(Ci)TotalQuantity(Ci)=Ar<<8+A REVISIONNo.:2PROCEDURENo.:EPIP-11PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTPAGE:80of83ATTACHMENT8DETAILEDRADIOLOGICALANALYSIS(Page14of17)DATASHEET8-6.RECORDOFSTEADYSTATEPOWERCORRECTION(ReferenceStep4.E.1)Unit:Average30DaysPowerLevel:Average4DaysPowerLevel:IsotopeKr87Xe131mXe133I131I132I133I135Kr87Xe131mXe133I131I132I133I135Cs134Rb88Te129Te132Sr89Ba140La140La142Pr144FuelHistoryGroupingPowerCorrectedPowerCorrectionEquilibriumSourceSourceFactorxInventoryInventoryGasGapInventory1.48E+054.13E+045.06E+066.98E+061.36E+065.58E+063.13E+06FuelPelletInventory3.67E+077.09E+051.28E+086.01E+079.61E+071.34E+081.27E+087.73E+065.28E+072.09E+079.60E+076.98E+071.21E+081.29E+081.11E+088.46E+07CorrectedSourceInventory=PowerCorrectionFactorxEquilibriumSourceInventory.'aluesfromReference2.1.4.Group1PowerCorrectionFactor=AverageLevelforPrior30Days/100.Group2PowerCorrectionFactor=AverageLevelforPrior4Days/100.
REVISIONNO.:PROCEDURENO.:PROCEDURETITLE:COREDAMAGEASSESSMENTPAGE:81of83EPIP-11ST.LUCIEPLANTUnit:ATTACHMENT8DETAILEDRADIOLOGICALANALYSIS(Page15of17)DATASHEET8-7.RECORDOFTRANSIENTPOWERCORRECTION(ReferenceStep3.D.5.B)Prior30DaysPowerHistory:Power~Pt~pt'T~tT'IsotopeKr87Xe131mXe133I131I132I133I135Kr87Xe131mXe133I131I132I133I135Cs134Rb88Te129Te132Sr89Ba140La140La142Pr144EquilibriumSourceInventory*xGasGapInventory1.48E+054.13E+045.06E+066.98E+061.36E+065.58E+063.13E+06FuelPelletInventory3.67E+077.09E+051.28E+086.01E+079.61E+071.34E+081.27E+087.73E+065.28E+072.09E+079.60E+076.98E+071.21E+081.29E+081.11E+088.46E+07PowerCorrectionFactorPowerCorrectedSourceInventoryCorrectedSourceInventory=PowerCorrectionFactorxEquilibriumSourceInventory.*ValuesfromReference2.1.4 REVISIONNO.:PROCEDURENo.:EPIP-11Unit:PROCEDURETITLE:COREDAMAGEASSESSMENTST.LUCIEPLANTATTACHMENT8DETAILEDRADIOLOGICALANALYSIS(Page16of17)DATASHEET8-8.RECORDOFPERCENTRELEASE(ReferenceStep4.F)(Page1of2)PAGE:82of83IsotopeTotalQuantityAvailableforRelease(Ci)(DataSheet8-5)PowerCorrectedSourceInventory(Ci)(DataSheet8-6or8-7)Percent*Kr87Xe131mXe133I131I132I133I135Kr87Xe131mXe133I131I132I133I135Cs134Rb88Te129Te132Sr89Ba140La140La142Pr144GasGapInventoryFuelPelletInventory*Percent=(TotalQuantityAvailableforRelease+PowerCorrectedSourceInventory)x100 REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:COREDAMAGEASSESSMENTPAGE:83of83EPIP-11ST.LUCIEPLANTATTACHMENT8DETAILEDRADIOLOGICALANALYSIS(Page17of17)DATASHEET8-8.RECORDOFPERCENTRELEASE(ReferenceStep4.F)(Page2of2)SummaryofResults:NOTEComparepercentcladdamage,percentfueloverheat,andpercentfuelmeltresultsobtainedfromtheradionuclideanalysistothoseobtainedfromtheauxiliaryindicatorsanalyses.Ifresultsareinagreement,thecoredamageassessmentiscomplete.Iftheresultsarenotinagreement,are-checkofbothanalysesmaybeperformedorcertainindicationsmaybediscountedbasedonengineeringjudgement.Preparedby:Reviewedby:Approvedby:Date:~~Date:~~Date:~j
Title:FPLST.LUCIEPLANTEMERGENCYPLANIMPLEMENTINGPROCEDURESAFETYRELATEDProcedureNo.EPIP-'t2CurrentRev.No.8EffectiveDate:12/20/00MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAINPSLResponsibleDepartment:EMERGENCYPREPAREDNESSRevisionSummaryI-zPROCEDUREPRODUCTIONRevision8-THISPROCEDUREHASBEENCOMPLETELYREWRITTEN.RemovedtrainingrequirementforFAPDT(First-AidPersonnelDecontaminationTram)trainingforChemistrypersonnel,addedstatementregardingSecurityFirstAidTraining,andmadeeditorialandadministrativechanges.(J.R.Walker,12/07/00)ANDAddedreferencetoNP-912,revisedGETprocedurenumber,updatedtrng.mgr.titlerevisedannualretrainingtoallowcreditfordrill/exerciseparticipation,identifieduseofPSUPTNcommontrainingmodules,deletedRMtrainingmodulefromqualreqforECOandNDDOandmadeadministrativechanges.(J.R.Walker,10/13/00)Revision7-EliminatedbackshiftparamedicpositionduetofirstrespondertrainingofSecuritypersonnel.(G.Varnes,08/08/00)Revision6-Addedcontrolsforpagers.(DonnaCalabrese,04/27/00)Revision5-RemovedPARtrainingfromthequalificationrequirementsfortheTSCDoseAssessorposition.(J.R.Walker,12/03/99)Revision4-Changedtitlethroughout(ProtectionServicesManager)andaddressedchangespromptedbyuseofPQDasofficialtrainingdatabase.(J.R.Walker,07/08/99)RevisionFRGReviewDate12/15/97RevisionFRGReviewDate812/07/00ApprovedByJ.ScarolaPlantGeneralManagerApprovedByR.G.WestPlantGeneralManagerN/ADesignatedApproverApprovalDate12/15/97ApprovalDate12/07/00SOPSDATEDOCTPROCEDUREDOCNEPIP-12svsCOMPCOMPLETEDITM8
REVISIONNo.:PROCEDURENo.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTTABLEOFCONTENTSPAGE:2of38SECTIONPAGE10PURPOSE~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
32.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTS~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~43.0RESPONSIBILITIES164.0DEFINITIONS~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~$815.0INSTRUCTIONS.~....~...~....~............~.~..~....105.1InitialTraining5.2AnnualRetraining5.3LossofEROQualifications...........5.4TrainingofSecurityPersonnel5.5FireBrigade....~.~~...~.~~~~...~.5.6TrainingExemptionsandSubstitutionsATTACHMENTS10131617~~~~18~...19ATTACHMENT1EMERGENCYRESPONSEORGANIZATIONCHANGEREQUEST..............~..~........20ATTACHMENT2EROINITIALTRAININGMATRIX....~~.~.~..ATIACHMENT3EROANNUALREQUALIFICATIONMATRIX.........30 REVISIONNO.:PROCEDURENO.:PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGPAGE:3of38EPIP-121.0PURPOSEST.LUCIEPLANT1.1ThisprocedureprovidestheEmergencyPlan(E-Plan)trainingrequirementsforsitepersonnelandpersonnelintheSt.LuciePlantEmergencyResponseOrganization(ERO)~1.2Inordertomaintainemergencypreparedness,personnelshouldbefamiliarwithcertainpre-plannedactionsspecifiedintheEmergencyPlanImplementingProcedures(EPIPs).Theprimaryobjectivesofthistrainingareasfollows:1.FamiliarizeappropriateindividualswiththeE-PlanandrelatedEPIPs.2.Instructindividualsintheirspecificdutiestoensureeffectiveandexpeditiousactionduringanemergency.3.PeriodicallypresentsignificantchangesinthescopeorcontentoftheE-PlanandtheEPIPs.4.Provideannualretrainingtoensurethatpersonnelarefamiliarwiththeiremergencydutiesandresponsibilities.5.Providethevariousemergencyorganizationgroupswiththerequiredtrainingthatwillensureanintegratedandpromptresponsetoanemergencysituation.1.3Theannualtrainingcyclenormallyoccursinthefirstquarterofeachyear.1.4TheE-PlanTrainingReviewCommitteeprovidesforthereviewandevaluationofchanges,theimpactontraining,andthedeterminationiftrainingisneededpriortothenextcycle.
REVISIONNo.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:4of3
82.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTSNOTEOneormoreofthefollowingsymbolsmaybeusedinthisprocedure:gIndicatesaRegulatorycommitmentmadebyTechnicalSpecifications,ConditionofLicense,Audit,LER,Bulletin,etc.,andshallNOTberevisedwithoutFacilityReviewGroupreviewandPlantGeneralManagerapproval.Indicatesamanagementdirective,vendorrecommendation,plantpracticeorothernon-regulatorycommitmentthatshouldNOTberevisedwithoutconsultationwiththeplantstaff.2.1References1.St.LuciePlantRadiologicalEmergencyPlan(E-Plan)2.Ql1-PR/PSL-1,SiteOrganization.3.QI-17-PSL-1,QualityAssuranceRecords.4.ADM-18.06,GeneralEmployeeTraining.5.AP1800022,FireProtectionPlan.6.ADM-11.11,SevereAccidentManagementGuidelinesProgramAdministration7.St.LuciePlantEmergencyResponseDirectory.8.NP-912,RespiratoryQualificationsRequirements2.2RecordsRequiredRecordsdocumentingtheEmergencyPlanTrainingreceivedbyindividualsareQualityAssurancerecordsandshallbemaintainedintheplantfilesinaccordancewithQI-17-PSL-1,QualityAssuranceRecords.
REVISIONNo.:PROCEDURENo.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:5of3
82.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTS(continued)2.3CommitmentDocuments1.10CFR50.47,EmergencyPlans.2.10CFR50,AppendixE,EmergencyPlanningandPreparednessforProductionandUtilizationFacilities.3.10CFR26,FitnessforDuty.4.NUREG0737,11.B.4,TrainingforMitigatingCoreDamage5.NOVResponseL-97-20,ViolationII.C,Part4A.6.NOVResponseL-97-20,ViolationII.C,Part4B.7.NRCInspectionReport96-18URIP5.28.QAS-EMP-96-01,Finding29.PMAIPM99-05-183(UseandUpdateofthePersonnelQualificationDatabase(PQD))10.PMAIPM99-09-077,CR99-1353(TrainingrequirementsforTSCDoseAssessor)11.CR00-0544,AuditQSL-EP-00-02(DiscrepancieswithPrimaryandBackupEROAugmentationProcesses)3.0RESPONSIBILITIES3.1TheSiteTrainingManagerisresponsiblefor:1.Designing,establishing,implementingandmaintainingtrainingprogramsfortheSt.LuciePlant.2.Ensuringinitialorientationtrainingisprovidedtopermanentlyassignednewemployees.
REVISIONNO.:PROCEDURENo.:PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGPAGE:6of38EPIP-12ST.LUCIEPLANT3.0RESPONSIBILITIES(continued)3.1TheSiteTrainingManagerisresponsiblefor:(continued)3.EnsuringallEmergencyPlanTraining,bothinitialtrainingandperiodicretraining,isconductedanddocumentedfortheSt.LuciePlantERO.3.2ProtectionServicesManagerisresponsiblefor:1.EnsuringthataqualifiedEmergencyResponseOrganization(ERO)ismaintainedincompliancewiththeSt.LucieRadiologicalEmergencyPlan.2.Coordinatingemergencyplanningattheplant.3.3EmergencyPreparednessisresponsiblefor:EstablishingqualificationsstandardsforEROpersonnel.A.Ensuringnon-bargainingunitpersonnelpagersarecorrectlyprogrammed.2.ReviewingandapprovingtheEmergencyPlanTrainingProgram.3.Offeringtrainingtoeachcontractedlocalhospital,atleastonceeachyear.A.Thecontentofthattrainingshouldconsistofradiologicalcontrols,medicalconsiderationofcontaminatedinjuries,andothertopicsasappropriate.4.OfferingtrainingtoeachStateandlocalemergencyresponseagency,atleastonceeachcalendaryear.A.Thecontentofthattrainingshouldconsistofanoverviewofnormalandemergencyplantoperationsandconceptsofradiationprotection,includingprotectiveactions.B.Thistrainingmaybeintheformofapresentation,text,orotheracceptablemeans.
REVISIONNo.:PROCEDURENo.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:7of383.0RESPONSIBILITIES(continued)3.3EmergencyPreparednessisresponsiblefor:(continued)5.ProvidingthetableofEmergencyActionLevels(EALs)tostateandlocalofficialsfortheirreview,onanannualbasis.6.RevisingtheSt.LuciePlantEmergencyResponseDirectory(ERD)andtheFPLEmergencyRecallSystem(autodialer)databasewhennotifiedviaaformsimilartoAttachment1~7.Providingalistofpersonneldesignatedtofillemergencyresponsepositionsandrequiringtrainingperthisprocedure,totheTrainingDepartment.8.RemovingindividualswhofailtomaintaintrainingqualificationsfromtheERDandtheFPLEmergencyRecallSystem(autodialer)databasewhennotifiedbytheappropriatedepartmentheadortheTrainingDepartment.9.ProvidingguidelinestoplantmanagementtoassistinidentifyingtheappropriatenumberofEROpersonnelforeachEROposition.10.NotifyingtheSiteTrainingManagerifchangesintheE-Planand/orEPIPsjustifyadditionaltrainingforEROpersonnel.11~ChairingEPTrainingReviewCommitteeMeetings.3.4EachManagerandDepartmentHeadisresponsibletoensurethateachEROmemberunderhis/hersupervisionattendstraininginaccordancewithAttachments2and3,andremainsfullyqualifiedatalltimestoperformhis/herassignedemergencyresponseduties.1.Ensurepersonnelinhis/herdepartmentwhoareassignedanon-sitepositionintheEROmaintainunescortedaccesstotheProtectedAreaandRadiationControlledArea.2.Ensurechangesinhis/heremployees'tatuswhichwouldimpairorlimittheabilitytoperformemergencyresponsedutiesbepromptlyreportedtotheProtectionServicesManager(directlyorthroughEP).A.Providealternatepersonneltobetrainedtofillopenpositions.
REVISIONNo.:PROCEDURENo.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:8of383.0RESPONSIBILITIES(continued)3.4(continued)3.Ensurethatnon-bargainingunitpersonnelhavepagers.3.5TheProtectionServicesManagerisresponsibletoensurethatSecuritypersonnelmaintainEPtrainingqualificationsperthisprocedure.3.6EROmembers,supervisors,'raininginstructors,HPdosimetrypersonnelandmedicalfacilitystaffareresponsibleforpromptlyreportinganyfailureintraining,testingorothercondition,whichwoulddisqualifyanemergencyresponder,totheProtectionServicesManager(directlyorthroughEP).3.7EachEROmemberisresponsibleforadvisingtheProtectionServicesManager(directlyorthroughEP)whenchangesinstatusoccurthatcouldimpactEROparticipation.4.0DEFINITIONS4.1Annual-occurringoncepercalendaryear(January1throughDecember31).4.2DutyCallSupervisor(DCS)-isaspecificallydesignatedandtrainedsupervisorresponsibleforassistingtheEmergencyCoordinatorinmakingnotificationsandcallstotheEmergencyResponseOrganization.4.3EmergencyPlan-formallyknownastheSt.LuciePlantRadiologicalEmergencyPlan,establishestherequirementsfortrainingtheEmergencyResponseOrganization;alsoreferredtoasthePlanorE-Plan.4.4EmergencyPlanning(EP)-activitiesundertakentosatisfythecommitmentsoftheEmergencyPlan,usedinterchangeablywithEmergencyPreparedness.4.5EmergencyResponseDirectory(ERD)-formallyknownastheSt.LuciePlantEmergencyResponseDirectory,providesalistofthecurrent(revisedonaquarterlybasis)EmergencyResponseOrganizationpersonnel.
REVISIONNO.:8PROCEDURENo.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:9of384.0DEFINITIONS(continued)4.6EmergencyResponseOrganization(ERO)-personneltrainedandqualifiedtoprovidespecificemergencyresponsefunctionsasdefinedbytheirindividualpositions.PersonscanbecomemembersoftheEmergencyResponseOrganizationbyfollowingtheinstructionsoutlinedinthisprocedure.4.7EPTrainingReviewCommittee(TRC)-representativesfromEmergencyPreparedness,Training,andotherdepartmentswhomeetperiodicallytodiscusstrainingissuesrelatedtotheEmergencyResponseOrganization.4.8SAMG-SevereAccidentManagementGuidelines.
REVISIONNO.:PROCEDURENo.:PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGPAGE:10of38EPIP-125.0INSTRUCTIONSST.LUCIEPLANTNOTEIntheeventofanemergency,theEmergencyCoordinatororRecoveryManagerhastheauthoritytoassignpersonneltopositionsforwhichtheyhavenotreceivedtherequiredEmergencyPlantraining,ifthatactionisprudentinordertoprotectthehealthandsafetyofthepublicandplantpersonnel~Thetrainingrequirementslistedinthisprocedureareforthepurposeofemergencypreparednessandareinadditiontoothertrainingrequiredtoholdaposition,e.g.,NuclearPlantSupervisor(NPS).PersonnelfillingthepositionofEmergencyCoordinator,TSCOPSCoordinator,orEOFRMOPSAdvisor/LogkeepershouldhaveSROlevelknowledge(i.e.,currentorpreviousSROlicenseorSROequivalenttrainingsuchasEngineeringManagementOperationsTraining(EMOT)).5.1InitialTrainingNOTEInitialTrainingisintendedforpersonnelwhoarenewtotheEROandisdesignedtoorienttheindividualtohis/herfunctionandresponsibilitieswithintheERO.DrillparticipationisnotrequiredpriortoqualifyingforanEROposition.Itmaybedesirabletoallowpersonsfillingthefollowingpositionstoparticipateinand/orobservetheirpositioninadrillpriortobeingassignedtotheERO:EmergencyCoordinatorRecoveryManagerTSCSupervisorOSCSupervisorTSCCoordinatorwiththeOSCOSCCoordinatorwiththeTSC1~InitialOrientationTraining(PlantAccessTraining-PAT)shallbeprovidedtopermanentlyassignednewemployees.
REVISIONNO.:PROCEDURENo.:PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGPAGE:11of38EPIP-125.0INSTRUCTIONS(continued)ST.LUCIEPLANT5.1InitialTraining(continued)(continued)A.Trainingincludesinformationdescribing:1~Actionstobetakenbyanindividualwhodiscoversanemergencycondition.2.Locationofassemblyareas.3.Identificationofemergencyalarms.4.Actiontobetakenuponhearingalarms.B.PATTrainingisconductedinaccordancewithADM-18.06,GeneralEmployeeTraining.2.PersonnelshallcompletetheInitialTrainingrequirementsidentifiedinAttachment2,EROInitialTrainingMatrix,priortobeingassignedtotheERO.3.TobecomeamemberoftheERO,anindividualshouldfilloutAttachment1,EmergencyResponseOrganizationChangeRequest.A.Completethepersonalinformation(originatorsection).B.ObtainDepartmentHeadapproval.C.ForwardtheAttachmenttoEmergencyPreparednessSupervisor.4.EmergencyPreparedness(EP)shouldauthorizethetrainingofpersonneldesignatedtobecomenewmembersoftheEROonAttachment1.
REVISIONNo.:PROCEDURENOEPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:12of385.0INSTRUCTIONS(continued)5.1InitialTraining(continued)5.TrainingDepartmentpersonnelshoulddocumentcompletionofrequiredtrainingonAttachment1andforwardtotheEmergencyPreparednessSupervisorwhennewmemberscompletethetrainingrequirementsasidentifiedinAttachment2,EROInitialTrainingMatrix.6.EPshouldmakechangestotheEmergencyRecallSystem(ERS)andtheEmergencyResponseDirectory(ERD)uponreceiptofAttachment1fromTechnicalTraining.ENDOFSECTION5.1 REVISIONNo.:PROCEDURENo.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:13of385.0INSTRUCTIONS(continued)NOTERetrainingisintendedtoensurethatEROpersonnelmaintainthelevelofskillandknowledgenecessarytoaccomplishtheiremergencyduties.Retrainingmaybeaccomplishedthroughacombinationofprogrammedinstructionand/orparticipationindrillsorexercises.5.2AnnualRetraining1~Annualretrainingshallbeprovidedatleastoncepercalendaryear.2.Annualretrainingmaybeaccomplishedbyclassroomtrainingordrill/exerciseparticipation.A.AnnualretrainingshallincludeareviewofsignificantchangesinthescopeorcontentoftheEmergencyPlanorapplicableEmergencyPlanImplementingProcedures.B.ClassroomtrainingshallincludetopicsidentifiedinAttachment3,EROAnnualRetrainingMatrix.C.TheEPTrainingReviewCommitteeshallidentifyadditionalannualretrainingtopics,whichmayinclude:-reviewofselectedinitialtrainingtopics-industryoperatingexperience-areviewofpastdrill/exerciseperformanceproblemsD.Drillparticipationshallincludeattendanceatthepre-drillfacilitybrief,participationasaplayer,controllerormentorandparticipationintheendofdrillcritique.1.TheEPTrainingReviewCommitteeshalldesignateannualretrainingtopicsandAttachment3topicsforwhichdrill/exerciseparticipationwillbeanacceptablealternative.E.OthertrainingmethodologiesmaybeusedonanasneededbasiswhenapprovedbytheEPTrainingReviewCommitteeandtheSiteTrainingManager.
REVISIONNo.:PROCEDURENo.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:14of385.0INSTRUCTIONS(continued)5.2AnnualRetraining(continued)3.Individualsmaychallengeannualretrainingexaminationsfortopicsnotaccountedforindrill/exerciseparticipation.4.PersonnelwhoteachaclassshouldreceivecreditforcompletionofthatclassatthediscretionoftheSiteTrainingManager.NOTEDeviationfromthisschedulerequirestheapprovalofthePresident,NuclearDivision.5.EmergencyResponseFacility(ERF)drillsshallbeconductedatleastfourtimespercalendaryearandshouldbeconductedapproximatelyonceeachquarter.NOTEItistheintentofthedrillandexerciseprogramthateachEROmemberhaveanopportunitytofunctioninhis/herpositionannually.A.ParticipationindrillsandexercisesshouldbetrackedbyEmergencyPreparednessSupervisorandforwardedtoTechnicalTraining.1.DrillrostersshouldbereviewedandusedtorecordparticipantsinallEmergencyResponseFacilities(ERFs)includingtheEmergencyNewsCenter(ENC).2.DrillcritiquesshouldlistPlayers,Controllers,Evaluators,MentorsandObserversforeachfacility.3.Drillparticipationshouldberecordedinthetrainingdatabase.
REVISIONNo.:PROCEDURENo.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:15of385.0INSTRUCTIONS(continued)5.2AnnualRetraining(continued)5.(continued)B.Personnelshouldberotatedthroughdrillsandexerciseswiththegoalofhavingasmanyasfeasibleparticipateinatleastonedrillorexerciseperyear.ThisappliestoallEROmembers,includingthosewhoareNOTintheNuclearDivision.1~ParticipationinadrillorexerciseshallberecognizedifanEROmemberfunctionsasaPlayer,MentororController.2.FailuretoparticipateinanERFdrillannuallymayresultinremedialtrainingasdeterminedbytheTrainingManagerandProtectionServicesManager.ENDOFSECTION5.2 REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:16of385.0INSTRUCTIONS(continued)5.3LossofEROQualifications1.Ifanindividualfailsaninitialtrainingtopic,ThenthatindividualshallnotbeassignedtotheEROuntilhe/shehassuccessfullymetrequirements.2.IfanindividualfailsPlantAccessTraining(PAT),RadiationControlledAreaTraining(RCAT),orfailstomaintainqualificationsforuseofrespiratoryprotection(asspecifiedinAttachment3),Thenhe/sheshallpromptlyberemovedfromtheERO.3.Ifanindividualfailsanannualretrainingevaluation,theSiteTrainingManagershallnotifytheEmergencyPreparednessSupervisorordesigneeoftheresults.A.TheindividualshouldthenberemovedfromtheERSandERDuntilappropriateremedialtraining,asrecommendedbytheSiteTrainingManagerandapprovedbytheEmergencyPreparednessSupervisor,hasbeencompleted.4.Theindividualshouldcompleteremedialtrainingattheearliestopportunity.ENDOFSECTION5.3 REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:17of385.0INSTRUCTIONS(continued)5.4TrainingforSecurityPersonnelSecuritypersonnelshallreceiveinitialtrainingandannualretrainingforemergencyresponseinaccordancewiththisprocedure.2.SecuritypersonnelshallreceiveFirstAidTeamtraininginaccordancewithSecurityprocedures.ENDOFSECTION5.4 REVISIONNO.:8PROCEDURENo.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:18of385.0INSTRUCTIONS(continued)5.5FireBrigade1~FireBrigadetrainingiscoveredbytheFireProtectionPlan,AP1800022.ENDOFSECTION5.5 REVISIONNo.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:19of385.0INSTRUCTIONS(continued)5.6TrainingExemptionsandSubstitutions1.NospecificEmergencyPlanTrainingisrequiredforEROpositionswhoseemergencyjobfunctionsaresimilartonormaljobfunctions.Examplesofthesepositionsinclude:A.EmergencyNewsCenter/CorporateCommunicationsStaffB.GovernmentalAffairsStaffC.RiskManagerD.RegulatoryAffairs2.PersonnelwhoparticipateinadrillorattendannualrequalificationtrainingatPTNmayreceivecredit/satisfytherequirementsfordrillparticipationand/orannualretrainingasrequiredbythisprocedure.EROpositionseligibletoreceivecreditinclude(butarenotlimitedto):A.EmergencyInformationManager(EIM)B.NuclearDivisionDutyOfficer(NDDO)C.EmergencyControlOfficer(ECO)ENDOFSECTION5.6 REVISIONNOPROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:20of38ATTACHMENT1EMERGENCYRESPONSEORGANIZATIONCHANGEREQUESTNOTEPersonnelwillnotbeassignedtoanemergencyresponseorganizationpositionuntilrequiredtrainingforthatpositioniscompleted.0RI6INAT0ROriginator:0Add0Remove0Change(Circlenewinfo)*Name:Soc.Sec.No.:*Positionnumber.*Position:WorkPhone:HomePhone:Pager:Other.Dept.DEPTHEADNOTENon-bargainingunitpersonnelwillnotbeassignedtoapositioniftheydonothaveapager.DepartmentHead/Supv.Signature:AuthorizationforEROtrainingEPSuervisorDate://TRAININ8g,0Theindividuallistedabovemeetsthetraining/qualificationrequirementsofEPIP-12fortheposition(s)indicatedperthePersonnelQualificationDatabase(PQD).0Theindividuallistedaboverequirestraining.NotifytheDept.Head,Dept.TrainingCoord.(ifapplicable)andtheTechnicalTrainingSupervisor.Signature:Q0Pagercorrectlyprogrammed:0EmergencyRecallSystemdatabaseupdated:0EmergencyResponseDirectory(draft)updated:0NotificationstoERO:$~0NotificationofPersonnelQualificationDatabase(PQD)AdministratorDate~~Date:~~Init.:Date:~~Init.:Date:~~Init.:Date:~~Init.:Date:~~Init.:Onlyinformationrequiredif~removinfromERO(byEP)ENDOFATTACHMENT1 REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:21of38ATTACHMENT2EROINITIALTRAININGMATRIX(Page1of9)ERO¹100101102POSITIONUcensedECSTANLOPS/SEC/FirstAidResponderDCSEmergencyCoordinatorTSCSupeNisor0CCDK0CIUJ'8C:0Q.CDKU.0LUC0KOV)I-EI-OV)0GGGGG'C0-8CDO0CEUJC0-80Z0CEIJIC0.?0KUJXXX'XL0O8X)K0Q.cogI-0'CCD3LO00O000OCDC00'0CDK0C0)CDEUJC0CI$Q.0CIJOOKLUGDCDECDCDLOC0CDCDOO0CDCD0)rJJUG'0CD8UJXOlCC?'0K103104105TSCHPSupervisorTSCChem.SupervisorTSCReactorEngineerGGXXXXXXX=BC=RequiredAccidentChemistryConsiderationsModuleRespiratorOnlyincludedinEROActivationtrainingforDCSonly:AutodialerJPMWrittenexamSimulatorpracticesessionwithE-PlaneventsIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSIJPTNCommonResponderVersion6=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPoolD=IncludedinEmerg.Rad.Monitoring REVISIONNO.:PROCEDURENo.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:22of38ATTACHMENT2EROINITIALTRAININGMATRIX(Page2of9)ERO¹POSITIONO0COo.C:OO)ELLJO'O3.OK0UJ'8COOKOVJI-EIoOKOVJ0OKCO8CCJOC7CEUJCOCO8OROELUCOC5O0LUO8OC)LOOKOO.VJOI0'CO8VJOOOEOPOOO)C0CKCOO)OELUCO0V)OIDKUJCOECOVJOC5COOCL0O'OCOOJ'OLneUZlC5cLICOC58LUOlCCCCII-ICCC)0OOK106TSCCommunicator107TSCEMPSTRep.108TSCMMPSTRep.109HPShiftSupervisor110TSCOPSCoordinatorQ111TSCDoseAssessor112TSCHPCommunicator113TSCSPPhonetalker114TSCERDADSOp.XGGXXXX8CRequiredAccidentChemistryConsiderationsModuleRespiratorOnlyIncludedinEROActivationtrainingforDCSonly:AutodialerJPMWrittenexamSimulatorpracticesessionwithE-PlaneventsIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSL/PTNCommonResponderVersionG=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPoolD=IncludedInEmerg.Rad.Monitoring REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:23of38ATTACHMENT2EROINITIALTRAININGMATRIX(Page3of9)ERO¹115116117118119120121POSITIONTSCPSTLeaderTSCERDADSTechTSCI&CPSTRep.TSCSROPSTRep.TSCSecuritySupv.TSCCoord.withOSCTSCAdminStaff0Co.EIll'OC0Ku.0LllGGGGGGCO8V)C4OCJCELllCO8OzEuJCOc5O0CCLllC0)QOC)OOChC7g'OCCOQ.COOI-OCJi:8LOC)OEC$OOOC:COC0cJKEuJCO0rllOOKLilCOECOiOC5OO00'ClCOD)coeuCOcdOcdLuCOCI-0K124151TSCECAssist/Log.OSCHPTech.GXGXXXXBCRequiredAccidentChemistryConsiderationsModuleRespiratorOnlyIndudedinEROActivationtrainingforDCSonly:AutodialerJPMWrittenexamSimulatorpracticesessionviithE-PlaneventsIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSt/PTNCommonResponderVersionG=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPoolD=IncludedinEmerg.Rad.Monitoring REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLEMAINTAININGEMERGENCYPREPAREDNESS-.RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:24of38ATTACHMENT2EROINITIALTRAININGMATRIX(Page4of9)ERO¹152153155156157158159POSITIONOSCEMRe-EntrySupv.OSCt&CRe-EntrySupv.OSCMMRe-EntrySupv.OSCChem.Supv.OSCElectricalChiefOSCSupervisorOSCCoord.viithTSCOSCHPSupv.OSCChemist0CcjKEIll'0C0O.KU.0LuL'00O.KOQlI-EI-OCjj0XGGGGGGGGGGGGC08CjjOEUJC080Z0ELuC0.)1l0KIllC0Cj'6ClL0OCjjK0LOgI-0CjjC:CDLOCD00OEg00P0O0$0C0C$KCjCCDPCDEUJC00CJIOOKUJCDECJIC0CjjOO00'0CI$0$'CLOCDU05C0DUJ0$CI-)0CDKXBCRequiredAccidentChemistryConsiderationsModuleRespiratorOnlyIndudedinEROActivationtrainingforDCSonly:Autodia'ierJPMWrittenexamSimulatorpracticesessionwithE-PlaneventsIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSUPTNCommonResponderVersionG=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPoolD=IncludedInEmerg.Rad.Monitoring REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLEMAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:25of38ATTACHMENT2EROINITIALTRAININGMATRIX(F'age5of9)ERO¹POSITIONCl?:0CCdo.0PCDEUJ'8C0O.LJ.U.0LU'CdC0O.KOCOI-EI-OCJJ00Cd0CDCDCdO0C0OC0ELLJCDC00z0CDILUC0Cd0LJ.LUCD00000OCDCDcc0riJI-0CdC3LrJEOQOCC0C0KC00rJIOOLJ:UJCDELOC0CdOO02.Cd8C0Cd00Cd)UJcdCCCdI-CD00K161OSCElectrician162OSCMechanic163OSC18CSpec.165OSCOn-ShiftSecuritySpec.166OSCDosi.Tech.166OSCMMForeman169OSCNMMStaffRep.170OSCSafetyRep.XXGGGGGGGGGGGXBCRequiredAccidentChemistryConsiderationsModu'leRespiratorOnlyincludedinEROActivationtrainingforDCSonly:Autodia'lerJPMWrittenexamSimulatorpracticesessionwithE-PlaneventsIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PStJPTNCommonResponderVersionG=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPoolD=IncludedinEmerg.Rad.Monitoring REVISIONNO.:PROCEDURENo.:EPIP-12PROCEDURETITLEMAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:26of38ATTACHMENT2EROINITIALTRAININGMATRIX(Page6of9)EROIPOSITION0CKP0EUJC0o.OcoI-EIOco0C08C500CEIUC080z0CEIUC0DCli00ccUJC:0800O0K0c1I-0C58coQ0OC5EC5O00OCOC0'0C5K0CCDEUJC00coOQKUJCDcoC0C5C0OO00'0C5CDCXICIUC505C0C58)IUCDC:CI-?'0K171OSCAdminTech/Log.172AssemblyAreaSupv.173OSCOPSRe-EntrySupv.174OSCProtandControlRep175OSCl8CShopSupv.176FieldMonTeamDriver177OSCInfoSenricesRep.200RecoveryManager205Govt.AffairsMgr.XXXXXGXGXGGXGXGGXGG/CXGHXXBCRequiredAccidentChemistryConsiderationsModuleRespiratorOnlyIncludedinEROActivationtrainingforDCSonly:AutodialerJPMWrittenexamSimulatorpracticesessionviithE-PlaneventsIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSUPTNCommonResponderVersionG=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPoolD=IncludedinEmerg.Rad.Monitoring REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:27of38ATTACHMENT2EROINITIALTRAININGMATRIX(Page7of9)ERO¹POSITION0Co.ELu'0C0O.U.0UJ'8C0IJ:OLJJIEI-OCJJ008C$OEUJC080ZEIJJC00CCC081$L-0O8)IZ0L$$'8I-08VJQ00C:0E0$CI$ECC$00000$C'00C0IJ:EUJC0Q.00$OOccUJCC$ECJJe0c$C0OO00C$0$'CroQUCCCC0CC$8LuCC:209EOFRMOPSAdv/Log.213EOFERDADSOp.216EOFStatusBoardKeeper230EOFEmergTechnicalMgr231EOFProjectEngineer232EOFMech.Engineer233EOFNudearEngineer235EOFNucFuelsEng.236EOFCivilEngineerXXXXXXXXXXXXXXXXXXXXXXBCRequiredAccidentChemistryConsiderationsModuleRespiratorOnlyIndudedinEROActivationtrainingforDCSonly:AutodialerJPMWrittenexamSimulatorpracticesessionwithE-PlaneventsIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSIJPTNCommonResponderVersionG=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPoolD=IndudedinEmerg.Rad.Monitoring REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:28of38ATTACHMENT2EROINITIALTRAININGMATRIX(Page8of9)COEROff237238240245246247255260POSITIONEOFl&CEngineerEOFElectricalEngineerEOFHPManagerEOFDosAssessor/FMTEOFHPTechSupportEOFRadStatBdsKeeperEOFNuc.Uc.Mgr.EOFCommunicatorEmerg.SecurityMgr.0Ccdo.OC0ELuC0O.KU.0LuXXI4C0CLC)KO(0I-EI-OLO0C08cdOOCPELuCO8OzOCELuCO0KLOO'8KOO.LOI-0cd8V)EOO0cdEcdOC)OOFOCO'LdKELuCOCL0U)OCiKLud)0)C045cdOCI0XEDOcdLd>CLnEUeOcd8cdLuI-LOOKXBCRequiredAccidentChemistryConsiderationsModuleRespiratorOnlyIndudedinEROActivationtrainingforDCSonly:AutodialerJPMWrittenexamSiinulatorpracticesessionwithE-PlaneventsIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSL/PTNCommonResponderVersionG=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPoolD=IncludedinEmerg.Rad.Monitoring REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLEMAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:29of38ATTACHMENT2EROINITIALTRAININGMATRIX(Page9of9)ERO¹POSITION00Co.0CPELll0C0Q.oKu.0ulI00Q.KOV)IEI-KOco0C08NOEulCOC080Z0C0O)EulC:0C50KLllC08000OmK0Q.co0I0'CCi3LO00OEgCI00O0)00C0Q.0COOOKLllEI-UOlECOCOC0CiClOO005$CDCLL)U558OILC0C$8)c5ulCDCCI-)00K270271273280281291294295EOFEmergInfoMgr.NDDOEIM/ENCTechAdvisorEOFAdminSupervisorEOFAdminStaffGovernor'sAdvisorSt.LucieCoTechAdvMartinCoTechAdvEmerControlOfficerEEEEXXXXXXXXXXEEX8CRequiredAccidentChemistryConsiderationsModuleRespiratorOnlyIncludedinEROActivationtrainingforDCSonly:AutodialerJPMWrittenexamSimulatorpracticesessionviithE-PlaneventsItqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSL/PTNCommonResponderVersionG=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPoolD=IncludedinEmerg.Rad.MonitoringENDOFATTACHMENT2 REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLEMAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:30of38ATTACHMENT3EROANNUALREQUALIFICATIONMATRIX(Page1of9)ERO¹POSITIONUcensedECC1CCCOI-coO0GG'O8ClOEUIC08OXfEUICCCL0C7)OOLOOOCCCOOOXX0CCCCOcoOOOEgOOOOFOC'DKEUJOO.0coOOKUlChECOcoC0CCCCOOO0CCiO>CZIOlCcI-K101102103105STANLOPS/Sec/FirstAidResponderEmergencyCoordinatorTSCSupenrisorTSCHPSupervisorTSCChem.SupervisorTSCReactorEngineeringTSCCommunicatorXXGGG'XXXXXXG'XB/GXBCRequiredAccidentChemistryConsiderationsModuleRespiratorOnlyIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSL/PTNCommonResponderVersionF=SAMGRequalFrequencyIAWADM-11.11G=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPool REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:31of38ATTACHMENT3EROANNUALREQUALIFICATIONMATRIX(Page2of9)ERO¹POSITION0I-CC'00.Cd0OCO00C5'ODC50C08ChCCCOOl0ECU0080ZEuj0O0CCCC00coCl0O0O0OOiC'00C:0KC0C$00.0coOOKLUCCCECOCOC0FCOO0'0CCCOCQlKI-8107TSCEMPSTRep.108TSCMMPSTRep.110TSCOPSCoordinator111TSCDoseAssessor112TSCHPCommunicator113TSCSPPhonetalker114TSCERDADSOp.115TSCPSTLeader116TSCERDADSTechX8CRequiredAccidentChemistryConsiderationsModuleRespiratorOnlyIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSL/PTNCommonResponderVersionF=SAMGRequalFrequencyIAWADM-11.11G=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPool REVISIONNO.:PROCEDURENo.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:32of38ATTACHMENT3EROANNUALREQUALIFICATIONMATRIX(Page3of9)ERO¹117118119120121124151152153POSITIONTSCl&CPSTRep.TSCSROPSTRep.TSCSecuritySupv.TSCCoord.viithOSCTSCAdminStaffTSCECAssist/Log.OSCHPTech.OSCEMRe-EntrySupv.OSCl&CRe-EntrySupv.0crCLDCiC0I-Clcr'DCl.DcrC00CODCLDC$CGGGGGCO8CI$08phEur08OEulXXr=O0gfl0r8ro0O0EgOO0O)C0C'DKCOCL0rn00KUJCOECiCOroCOC$0O08XBCRequiredAccidentChemistryConsiderationsModuleRespiratorOnlyIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSUPTNCommonResponderVersionF=SAMGRequalFrequencyIAWADM-11.11G=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPool REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:33of38ATTACHMENT3EROANNUALREQUALIFICATIONMATRIX(Page4of9)ERO¹155156157159160161162POSITIONOSCMMRe-EntrySupv.OSCChem.Supv.OSCElectricalChiefOSCSupervisorOSCCoord.viithTSCOSCHPSupv.OSCChemistOSCElectricianOSCMechanicCCCO.C5OCCCC1.DCCCOC00OCCC'OO.DCCCCGGGGGGGGGGGGGCOEOCCCCCCOPOELLLO8OXfELUL=00m'ZlLi0CCCCClOLOO0CVEOOO0OCCOc'OClLL:ELUC:0O.0LOOOLL:LUCCiEOCllLOCOClCl0O0B/GG'OCCCOCLnOIc.OCCCCOI-8LL:XBCRequiredAccidentChemistryConsiderationsModuleRespiratorOnlyIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSUPTNCommonResponderVersionF=SAMGRequaiFrequencyIAWADM-11.11G=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPool REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLEMAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:34of38ATIACHMENT3EROANNUALREQUALIFICATIONMATRIX(Page5of9)ERO¹163165166166169170171172POSITIONOSCIll'CSpec.OSCOn.ShiftSecurity(Spec.)OSCDosi.Tech.OSCMMForemanOSCNMMStaffRep.OSCSafetyRep.OSCAdminTech/Log.AssemblyAreaSupv.C5'OO.DC5CC5O.DC5CO0XXXC5O.DC5CGGGGGGGGGGC08EhCOC50OOEluC5C0OzELuCOOOO5f'8OC5COroOClOOEgC5EOOOOCOKELUCOEO.0V)OOUJCOEC5V)0C5OO0OC5cnEKO>C5I-OlOO5iKXBCRequiredAccidentChemistryConsiderationsModuleRespiratorOnlyIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSL/PTNCommonResponderVersionF=SAMGRequalFrequencyIAWADM-11.11G=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPool REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:35of38ATTACHMENT3EROANNUALREQUALIFICATIONMATRIX(Page6of9)ERO¹POSITIONOV)L-Ci'DO.CCCO0C)CCO.DCCOCu0LU3OLL:COCCCiOELUO08OzELUCCCOOClL:OOCCOCC)C$OCCCOOLOCIOOOCCEcC0OOOOiC'C0COLL:CO0LOO0LL.LUCCEOCCLOCOCCOO0OiCECCLO)173OSCOPSRe-EntrySupv.174OSCProtandControlRep175OSCl&CShopSupv.176FieldMonTeamDriver177OSCInfoServicesRep.200RecoveryManager205Govt.AffairsMgr.209EOFRMOPSAdvAog.213EOFERDADSOp.GGGGGG/CXHXHXHXXXXXBCRequiredAccidentChemistryConsiderationsModuleRespiratorOnlyIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSUPTNCommonResponderVersionF=SAMGRequalFrequencyIAWADM-11.11G=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPool REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLEMAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:36of38ATTACHMENT3EROANNUALREQUALIFlCATIONMATRIX(fage7Of9)EROff216230231232236237POSITIONEOFStatusBoardKeeperEOFEmergTechnicalMgrEOFProjectEngineerEOFMech.EngineerEOFNuclearEngineerEOFNucFuelsEng.EOFCivilEngineerEOFl&CEngineerEOFElectricalEngineer0C$'00.DCi000C500.DC$0Oco00C0u0LUXHXHXHXHXHXHXHXHXHC08CCCOELU08C0zELU00'600L000COj0CJ0CCCC0LO0000CCCEO00OlO0c00O.0coOOIZLLINECOco00COOO000CCi'Ccn0ti.CbC:0CCCI-Ol000LL:XBCRequiredAccidentChemistryConsiderationsModuleRespiratorOnlyIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSUPTNCommonResponderVersionF=SAMGRequalFrequencyIAWADM-11.11G=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPool REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:37of38ATTACHMENT3EROANNUALREQUALIFICATIONMATRIX(Page8of9)EROff240245246247255260270271POSITIONEOFHPManagerEOFDoseAssessor/FMTEOFHPTechSupportEOFRadStatBdsKeeperEOFNuc.Uc.Mgr.EOFCommunicatorEmeig.SecurityMgr.EOFEmergInfoMgr.NDDOOC$O.CSCiCi'OO.DCDOC00OC$'OO.DC5OcXHXHXHXHXHXHXHEHEHC:O0ELUC08OZELUXXCOOOtOOO'OO0CDOOLOOCiO0OCDC5ECi0LDO0CDCOCOLL:ELUOQ.0V)OQLLLUCDEOCOcdXOO0C)'OcdO>LnOIL.CDCiI-lOlOOCiLL:XBCRequiredAccidentChemistryConsiderationsModuleRespiratorOnlyIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSL/PTNCommonResponderVersionF=SAMGRequalFrequencyIAWADM-11.11G=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPool 0REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLEMAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:38of38ATTACHMENT3EROANNUALREQUALIFICATIONMATRIX(Page9of9)ERO¹273280281291294295POSITIONEIM/ENCTechAdvisorEOFAdminSupervisorEOFAdminStaffGovernor'sAdvisorSt.LuciaCoTechAdvisorMartinCoTechAdvisorEmergencyControlOfficerC$'OCL6$CC$'DaDc4C00C$'DCLC$DCO8C$OELUC:O8OZEluXXL-00ieOOOOOD)COCOClj0(0OOKul0)EEOV)$Oe$COO0C$C$$'arneuXBCRequiredAccidentChemistryConsiderationsModuleRespiratorOnlyIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSVPTNCommonResponderVersionF=SAMGRequalFrequencyIAWADM-11.11G=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPoolENDOFATTACHMENT3
~5~-955rfeHQ~gaYN4~l~+dg4J~xr/o/~&zoizgvcu~Title:FPLST.LUCIEPLANTEMERGENCYPLANIMPLEMENTINGPROCEDURESAFETYRELATEDProcedureNo.EPIP-12CurrentRev.No.~'Effective>Date:07/25/01MAINTAININGEMERGENCYPPAREDNESS-RADIOLOI'CALERGENCYPLANTRAPSLResponsibleDepartmt:EMERGENCYPREPAREDNESRevisionSummaryRevision9-RevisedChemirytrainingrelativetoPAelimin(J.R.Walker,07/23/01)K0ORevision8-THISPROCEDUREgSBEENCOPLETELYREWRITTEN.RemovedtrainingrequirementforFAPDT(First-ApdPersonelDecontaminationTram)trainingforChemistrypersonnel,addedstatementreardinSecurityFirstAidTraining,andmadeeditorialandadministrativechanges.(J.R.Wlker,12/07/00)DAddedreferencetoNP-912,revisedGETgocdurenumber,updatedtrng.mgr.titlerevisedannualretrainingtoallowcreditfgFdrill/eerciseparticipation,identifieduseofPSL/PTNcommontrainingmodules,de&tedRMtiningmodulefromqualreqforECOandNDDOandmadeadministrativechanes.(J.R.Wker,10/13/00)Revision7-EliminatedbackshifaramedicpositionetofirstrespondertrainingofSecuritypersonnel.(G.Varnes,08/08/00)Revision6-Addedcontroforpagers.(DonnaCalabres04/27/00)RevisionFRGReviDate012/5/97RevisionFRG~eviewDate907/23/01ApprovedByJ.ScarolaPlantGeneralManagerApprovedByR.G.WestPlantGeneralManagerN/ADesignatedApproverN/ADesignatedApprover(MinorCorrection)Approval~ate12/15/97ApprovalDate07/23/01SOPSDATEDOCTPROCEDUREDOCNEPIP-12ASCPMPCOMPLETEDITMX9 4IEt~,Il~3'i~~s"vt" REVISIONNo.:PROCEDURENOEPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTTABLEOFCONTENTSPAGE:2of38SECTION1.0PURPOSEPAGE~~~0~
32.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTS~........~.~.............~..~.~.~~~~43.0RESPONSIBILITIES4.0DEFINITIONS......~~~~~~~~~~~85.0INSTRUCTIONS.~.~......~.........~.~..~105.1InitialTraining5.2AnnualRetraining5.3LossofEROQualifications........~.5.4TrainingofSecurityPersonnel.~~....5.5FireBrigade.....~~~~............5.6TrainingExemptionsandSubstitutionsATTACHMENTS~~~~~101316~......17.......1819ATTACHMENT1EMERGENCYRESPONSEORGANIZATIONCHANGEREQUEST..~................20ATTACHMENT2EROINITIALTRAININGMATRIX.....21ATTACHMENT3EROANNUALREQUALIFICATIONMATRIX...~..30 REVISIONNo.:PROCEDURENo.:EPIP-121.0PURPOSEPROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:3of381.1ThisprocedureprovidestheEmergencyPlan(E-Plan)trainingrequirementsforsitepersonnelandpersonnelintheSt.LuciePlantEmergencyResponseOrganization(ERO).1.2Inordertomaintainemergencypreparedness,personnelshouldbefamiliarwithcertainpre-plannedactionsspecifiedintheEmergencyPlanImplementingProcedures(EPIPs).Theprimaryobjectivesofthistrainingareasfollows:1.FamiliarizeappropriateindividualswiththeE-PlanandrelatedEPIPs.2.Instructindividualsintheirspecificdutiestoensureeffectiveandexpeditiousactionduringanemergency.3.PeriodicallypresentsignificantchangesinthescopeorcontentoftheE-PlanandtheEPIPs.4.Provideannualretrainingtoensurethatpersonnelarefamiliarwiththeiremergencydutiesandresponsibilities.5.Providethevariousemergencyorganizationgroupswiththerequiredtrainingthatwillensureanintegratedandpromptresponsetoanemergencysituation.1.3Theannualtrainingcyclenormallyoccursinthefirstquarterofeachyear.1.4TheE-PlanTrainingReviewCommitteeprovidesforthereviewandevaluationofchanges,theimpactontraining,andthedeterminationiftrainingisneededpriortothenextcycle.
CREVISIONNo.:PROCEDURENO.:PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGPAGE:4of38EPIP-12ST.LUCIEPLANT
2.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTSNOTEOneormoreofthefollowingsymbolsmaybeusedinthisprocedure:gIndicatesaRegulatorycommitmentmadebyTechnicalSpecifications,ConditionofLicense,Audit,LER,Bulletin,etc.,andshallNOTberevisedwithoutFacilityReviewGroupreviewandPlantGeneralManagerapproval.Indicatesamanagementdirective,vendorrecommendation,plantpracticeorothernon-regulatorycommitmentthatshouldNOTberevisedwithoutconsultationwiththeplantstaff.2.1References1.St.LuciePlantRadiologicalEmergencyPlan(E-Plan)2.Ql1-PR/PSL-1,SiteOrganization.3.QI-17-PSL-1,QualityAssuranceRecords.4.ADM-18.06,GeneralEmployeeTraining.5.AP1800022,FireProtectionPlan.6.ADM-11.11,SevereAccidentManagementGuidelinesProgramAdministration7.St.LuciePlantEmergencyResponseDirectory.8.NP-912,RespiratoryQualificationsRequirements2.2RecordsRequiredRecordsdocumentingtheEmergencyPlanTrainingreceivedbyindividualsareQualityAssurancerecordsandshallbemaintainedintheplantfilesinaccordancewithQI-17-PSL-1,QualityAssuranceRecords.
REVISIONNo.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:5of3
82.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTS(continued)2.3CommitmentDocuments1.10CFR50.47,EmergencyPlans.2.10CFR50,AppendixE,EmergencyPlanningandPreparednessforProductionandUtilizationFacilities.3.10CFR26,FitnessforDuty.4.NUREG0737,11.B.4,TrainingforMitigatingCoreDamage5.NOVResponseL-97-20,ViolationII.C,Part4A.6.NOVResponseL-97-20,ViolationII.C,Part4B.7.NRCInspectionReport96-18URIP5.28.QAS-EMP-96-01,Finding29.PMAIPM99-05-183(UseandUpdateofthePersonnelQualificationDatabase(PQD))10.PMAIPM99-09-077,CR99-1353(TrainingrequirementsforTSCDoseAssessor)11.CR00-0544,AuditQSL-EP-00-02(DiscrepancieswithPrimaryandBackupEROAugmentationProcesses)3.0RESPONSIBILITIES3.1TheSiteTrainingManagerisresponsiblefor:1~Designing,establishing,implementingandmaintainingtrainingprogramsfortheSt.LuciePlant.2.Ensuringinitialorientationtrainingisprovidedtopermanentlyassignednewemployees.
REVISIONNo.:PROCEDURENo.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:6of383.0RESPONSIBILITIES(continued)3.1TheSiteTrainingManagerisresponsiblefor:(continued)3.EnsuringallEmergencyPlanTraining,bothinitialtrainingandperiodicretraining,isconductedanddocumentedfortheSt.LuciePlantERO.3.2ProtectionServicesManagerisresponsiblefor:EnsuringthataqualifiedEmergencyResponseOrganization(ERO)ismaintainedincompliancewiththeSt.LucieRadiologicalEmergencyPlan.2.Coordinatingemergencyplanningattheplant.3.3EmergencyPreparednessisresponsiblefor:1.EstablishingqualificationsstandardsforEROpersonnel.A.Ensuringnon-bargainingunitpersonnelpagersarecorrectlyprogrammed.2.ReviewingandapprovingtheEmergencyPlanTrainingProgram.3.Offeringtrainingtoeachcontractedlocalhospital,atleastonceeachyear.A.Thecontentofthattrainingshouldconsistofradiologicalcontrols,medicalconsiderationofcontaminatedinjuries,andothertopicsasappropriate.4.OfferingtrainingtoeachStateandlocalemergencyresponseagency,atleastonceeachcalendaryear.A.Thecontentofthattrainingshouldconsistofanoverviewofnormalandemergencyplantoperationsandconceptsofradiationprotection,includingprotectiveactions.B.Thistrainingmaybeintheformofapresentation,text,orotheracceptablemeans.
REVISIONNo.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:7of383.0RESPONSIBILITIES(continued)3.3EmergencyPreparednessisresponsiblefor:(continued)5.ProvidingthetableofEmergencyActionLevels(EALs)tostateandlocalofficialsfortheirreview,onanannualbasis.6.RevisingtheSt.LuciePlantEmergencyResponseDirectory(ERD)andtheFPLEmergencyRecallSystem(autodialer)databasewhennotifiedviaaformsimilartoAttachment1.7.Providingalistofpersonneldesignatedtofillemergencyresponsepositionsandrequiringtrainingperthisprocedure,totheTrainingDepartment.8.RemovingindividualswhofailtomaintaintrainingqualificationsfromtheERDandtheFPLEmergencyRecallSystem(autodialer)databasewhennotifiedbytheappropriatedepartmentheadortheTrainingDepartment.9.ProvidingguidelinestoplantmanagementtoassistinidentifyingtheappropriatenumberofEROpersonnelforeachEROposition.10.NotifyingtheSiteTrainingManagerifchangesintheE-Planand/orEPIPsjustifyadditionaltrainingforEROpersonnel.11.ChairingEPTrainingReviewCommitteeMeetings.3.4EachManagerandDepartmentHeadisresponsibletoensurethateachEROmemberunderhis/hersupervisionattendstraininginaccordancewithAttachments2and3,andremainsfullyqualifiedatalltimestoperformhis/herassignedemergencyresponseduties.1.Ensurepersonnelinhis/herdepartmentwhoareassignedanon-sitepositionintheEROmaintainunescortedaccesstotheProtectedAreaandRadiationControlledArea.2.Ensurechangesinhis/heremployees'tatuswhichwouldimpairorlimittheabilitytoperformemergencyresponsedutiesbepromptlyreportedtotheProtectionServicesManager(directlyorthroughEP).A.Providealternatepersonneltobetrainedtofillopenpositions.
0 REVISIONNo.:PROCEDURENo.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:8of383.0RESPONSIBILITIES(continued)3.4(continued)3.Ensurethatnon-bargainingunitpersonnelhavepagers.3.5TheProtectionServicesManagerisresponsibletoensurethatSecuritypersonnelmaintainEPtrainingqualificationsperthisprocedure.3.6EROmembers,supervisors,traininginstructors,HPdosimetrypersonnelandmedicalfacilitystaffareresponsibleforpromptlyreportinganyfailureintraining,testingorothercondition,whichwoulddisqualifyanemergencyresponder,totheProtectionServicesManager(directlyorthroughEP).3.7EachEROmemberisresponsibleforadvisingtheProtectionServicesManager(directlyorthroughEP)whenchangesinstatusoccurthatcouldimpactEROparticipation.4.0DEFINITIONS4.1Annual-occurringoncepercalendaryear(January1throughDecember31).4.2DutyCallSupervisor(DCS)-isaspecificallydesignatedandtrainedsupervisorresponsibleforassistingtheEmergencyCoordinatorinmakingnotificationsandcallstotheEmergencyResponseOrganization.4.3EmergencyPlan-formallyknownastheSt.LuciePlantRadiologicalEmergencyPlan,establishestherequirementsfortrainingtheEmergencyResponseOrganization;alsoreferredtoasthePlanorE-Plan.4AEmergencyPlanning(EP)-activitiesundertakentosatisfythecommitmentsoftheEmergencyPlan,usedinterchangeablywithEmergencyPreparedness.4.5EmergencyResponseDirectory(ERD)-formallyknownastheSt.LuciePlantEmergencyResponseDirectory,providesalistofthecurrent(revisedonaquarterlybasis)EmergencyResponseOrganizationpersonnel.
REVISIONNo.:PROCEDURENo.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:9of384.0'EFINITIONS(continued)4.6EmergencyResponseOrganization(ERO)-personneltrainedandqualifiedtoprovidespecificemergencyresponsefunctionsasdefinedbytheirindividualpositions.PersonscanbecomemembersoftheEmergencyResponseOrganizationbyfollowingtheinstructionsoutlinedinthisprocedure.4.7EPTrainingReviewCommittee(TRC)-representativesfromEmergencyPreparedness,Training,andotherdepartmentswhomeetperiodicallytodiscusstrainingissuesrelatedtotheEmergencyResponseOrganization.4.8SAMG-SevereAccidentManagementGuidelines.
REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGPAGE:10of38EPIP-125.0INSTRUCTIONSST.LUCIEPLANTNOTEIntheeventofanemergency,theEmergencyCoordinatororRecoveryManagerhastheauthoritytoassignpersonneltopositionsforwhichtheyhavenotreceivedtherequiredEmergencyPlantraining,ifthatactionisprudentinordertoprotectthehealthandsafetyofthepublicandplantpersonnel.Thetrainingrequirementslistedinthisprocedureareforthepurposeofemergencypreparednessandareinadditiontoothertrainingrequiredtoholdaposition,e.g.,NuclearPlantSupervisor(NPS).PersonnelfillingthepositionofEmergencyCoordinator,TSCOPSCoordinator,orEOFRMOPSAdvisor/LogkeepershouldhaveSROlevelknowledge(i.e.,currentorpreviousSROlicenseorSROequivalenttrainingsuchasEngineeringManagementOperationsTraining(EMOT))~5.1InitialTrainingNOTEInitialTrainingisintendedforpersonnelwhoarenewtotheEROandisdesignedtoorienttheindividualtohis/herfunctionandresponsibilitieswithintheERO.DrillparticipationisnotrequiredpriortoqualifyingforanEROposition.Itmaybedesirabletoallowpersonsfillingthefollowingpositionstoparticipateinand/orobservetheirpositioninadrillpriortobeingassignedtotheERO:EmergencyCoordinatorRecoveryManagerTSCSupervisorOSCSupervisorTSCCoordinatorwiththeOSCOSCCoordinatorwiththeTSC1.InitialOrientationTraining(PlantAccessTraining-PAT)shallbeprovidedtopermanentlyassignednewemployees.
REVISIONNo.:PROCEDURENo.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:11of385.0INSTRUCTIONS(continued)5.1InitialTraining(continued)1.(continued)A.Trainingincludesinformationdescribing:Actionstobetakenbyanindividualwhodiscoversanemergencycondition.2.Locationofassemblyareas.3.Identificationofemergencyalarms.4.Actiontobetakenuponhearingalarms.B.PATTrainingisconductedinaccordancewithADM-18.06,GeneralEmployeeTraining.2.PersonnelshallcompletetheInitialTrainingrequirementsidentifiedinAttachment2,EROInitialTrainingMatrix,priortobeingassignedtotheERO.3.TobecomeamemberoftheERO,anindividualshouldfilloutAttachment1,EmergencyResponseOrganizationChangeRequest.A.Completethepersonalinformation(originatorsection).B.ObtainDepartmentHeadapproval.C.ForwardtheAttachmenttoEmergencyPreparednessSupervisor.4.EmergencyPreparedness(EP)shouldauthorizethetrainingofpersonneldesignatedtobecomenewmembersoftheEROonAttachment1.
REVISIONNo.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:12of385.0INSTRUCTIONS(continued)5.1InitialTraining(continued)5.TrainingDepartmentpersonnelshoulddocumentcompletionofrequiredtrainingonAttachment1andforwardtotheEmergencyPreparednessSupervisorwhennewmemberscompletethetrainingrequirementsasidentifiedinAttachment2,EROInitialTrainingMatrix.6.EPshouldmakechangestotheEmergencyRecallSystem(ERS)andtheEmergencyResponseDirectory(ERD)uponreceiptofAttachment1fromTechnicalTraining.ENDOFSECTION5.1 REVISIONNO.:PROCEDURENo.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:13of385.0INSTRUCTIONS(continued)NOTERetrainingisintendedtoensurethatEROpersonnelmaintainthelevelofskillandknowledgenecessarytoaccomplishtheiremergencyduties.Retrainingmaybeaccomplishedthroughacombinationofprogrammedinstructionand/orparticipationindrillsorexercises.5.2AnnualRetraining1.Annualretrainingshallbeprovidedatleastoncepercalendaryear.2.Annualretrainingmaybeaccomplishedbyclassroomtrainingordrill/exerciseparticipation.A.AnnualretrainingshallincludeareviewofsignificantchangesinthescopeorcontentoftheEmergencyPlanorapplicableEmergencyPlanImplementingProcedures.B.ClassroomtrainingshallincludetopicsidentifiedinAttachment3,EROAnnualRetrainingMatrix.C.TheEPTrainingReviewCommitteeshallidentifyadditionalannualretrainingtopics,whichmayinclude:-reviewofselectedinitialtrainingtopics-industryoperatingexperience-areviewofpastdrill/exerciseperformanceproblemsD.Drillparticipationshallincludeattendanceatthepre-drillfacilitybrief,participationasaplayer,controllerormentorandparticipationintheendofdrillcritique.1~TheEPTrainingReviewCommitteeshalldesignateannualretrainingtopicsandAttachment3topicsforwhichdrill/exerciseparticipationwillbeanacceptablealternative.E.OthertrainingmethodologiesmaybeusedonanasneededbasiswhenapprovedbytheEPTrainingReviewCommitteeandtheSiteTrainingManager.
REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGPAGE:14of38EPIP-125.0INSTRUCTIONS(continued)ST.LUCIEPLANT5.2AnnualRetraining(continued)3.Individualsmaychallengeannualretrainingexaminationsfortopicsnotaccountedforindrill/exerciseparticipation.4.PersonnelwhoteachaclassshouldreceivecreditforcompletionofthatclassatthediscretionoftheSiteTrainingManager.NOTEDeviationfromthisschedulerequirestheapprovalofthePresident,NuclearDivision.5.EmergencyResponseFacility(ERF)drillsshallbeconductedatleastfourtimespercalendaryearandshouldbeconductedapproximatelyonceeachquarter.NOTEItistheintentofthedrillandexerciseprogramthateachEROmemberhaveanopportunitytofunctioninhis/herpositionannually.A.ParticipationindrillsandexercisesshouldbetrackedbyEmergencyPreparednessSupervisorandforwardedtoTechnicalTraining.1.DrillrostersshouldbereviewedandusedtorecordparticipantsinallEmergencyResponseFacilities(ERFs)includingtheEmergencyNewsCenter(ENC).2.DrillcritiquesshouldlistPlayers,Controllers,Evaluators,MentorsandObserversforeachfacility.3.Drillparticipationshouldberecordedinthetrainingdatabase.
REVISIONNO.:PROCEDURENo.:PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGPAGE:15of38EPIP-125.0INSTRUCTIONS(continued)ST.LUCIEPLANT5.2AnnualRetraining(continued)5.(continued)54lgB.Personnelshouldberotatedthroughdrillsandexerciseswiththegoalofhavingasmanyasfeasibleparticipateinatleastonedrillorexerciseperyear.ThisappliestoallEROmembers,includingthosewhoareNOTintheNuclearDivision.1.ParticipationinadrillorexerciseshallberecognizedifanEROmemberfunctionsasaPlayer,MentororController.2.FailuretoparticipateinanERFdrillannuallymayresultinremedialtrainingasdeterminedbytheTrainingManagerandProtectionServicesManager.ENDOFSECTION5.2 REVISIONNo.:PROCEDURENO.:EPIP-]2PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:16of385.0INSTRUCTIONS(continued)$35.3LossofEROQualifications1.Ifanindividualfailsaninitialtrainingtopic,ThenthatindividualshallnotbeassignedtotheEROuntilhe/shehassuccessfullymetrequirements.2.IfanindividualfailsPlantAccessTraining(PAT),RadiationControlledAreaTraining(RCAT),orfailstomaintainqualificationsforuseofrespiratoryprotection(asspecifiedinAttachment3),Thenhe/sheshallpromptlyberemovedfromtheERO.3.Ifanindividualfailsanannualretrainingevaluation,theSiteTrainingManagershallnotifytheEmergencyPreparednessSupervisorordesigneeoftheresults.A.TheindividualshouldthenberemovedfromtheERSandERDuntilappropriateremedialtraining,asrecommendedbytheSiteTrainingManagerandapprovedbytheEmergencyPreparednessSupervisor,hasbeencompleted.4.Theindividualshouldcompleteremedialtrainingattheearliestopportunity.ENDOFSECTION5.3 REVISIONNo.:9PROCEDURENo.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:17of385.0INSTRUCTIONS(continued)5.4TrainingforSecurityPersonnel1.Securitypersonnelshallreceiveinitialtrainingandannualretrainingforemergencyresponseinaccordancewiththisprocedure.2.SecuritypersonnelshallreceiveFirstAidTeamtraininginaccordancewithSecurityprocedures.ENDOFSECTION5.4 REVISIONNO.:PROCEDURENo.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:18of385.0INSTRUCTIONS(continued)5.5FireBrigade1~FireBrigadetrainingiscoveredbytheFireProtectionPlan,AP1800022.ENDOFSECTION5.5 REVISIONNo.:PROCEDURENo.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:19of385.0INSTRUCTIONS(continued)5.6TrainingExemptionsandSubstitutions1~NospecificEmergencyPlanTrainingisrequiredforEROpositionswhoseemergencyjobfunctionsaresimilartonormaljobfunctions.Examplesofthesepositionsinclude:A.EmergencyNewsCenter/CorporateCommunicationsStaffB.GovernmentalAffairsStaffC.RiskManagerD.RegulatoryAffairs2.PersonnelwhoparticipateinadrillorattendannualrequalificationtrainingatPTNmayreceivecredit/satisfytherequirementsfordrillparticipationand/orannualretrainingasrequiredbythisprocedure.EROpositionseligibletoreceivecreditinclude(butarenotlimitedto):A.EmergencyInformationManager(EIM)B.NuclearDivisionDutyOfficer(NDDO)C.EmergencyControlOfficer(ECO)ENDOFSECTION5.6 REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:20Of38ATTACHMENT1EMERGENCYRESPONSEORGANIZATIONCHANGEREQUESTNOTEPersonnelwillnotbeassignedtoanemergencyresponseorganizationpositionuntilrequiredtrainingforthatpositioniscompleted.0RIGINAT0ROriginator:0Add0Remove0Change(Circlenewinfo)Name:Soc.Sec.No.:"Positionnumber:*Position:WorkPhone:HomePhone:Pager:Other:Dept.1lNOTEDEPTNon-bargainingunitpersonnelwillnotbeassignedtoapositioniftheydonothaveaHEADDepartmentHead/Supv.Signature:EPEPSuervisorAuthorizationforEROtrainingDate:/'/TRAININ6$,0Theindividuallistedabovemeetsthetraining/qualificationrequirementsofEPIP-12fortheposition(s)indicatedperthePersonnelQualificationDatabase(PQD).0Theindividuallistedaboverequirestraining.NotifytheDept.Head,Dept.TrainingCoord.(ifapplicable)andtheTechnicalTrainingSupervisor.Signature:Q0Pagercorrectlyprogrammed:0EmergencyRecallSystemdatabaseupdated:0EmergencyResponseDirectory(draft)updated:0NotificationstoERO:fl,0NotificationofPersonnelQualificationDatabase(PQD)AdministratorDate~~Date:~~Init.:Date:~~Init.:Date:~~Init.:Date:~~Init.:Date:~~Init.:Onlyinformationrequiredii~removinfromERO(byEP)ENDOFATTACHMENT1 REVISfONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:21of38ATTACHMENT2EROINITIALTRAININGMATRIX(Page1of9)EROffPOSITION2O0CcCo.OCEUJOO0CLKU.0UJKK0i/JI-EQI-OCIJ0C0c5OOOCClELuCO8OzOCC)CCbEUJC00KIJJChOOOCiOOCOChOaC)'OOcC8r/J0OOOOOOJC0COcCKOCELJJCOO.0V)OOKUJECCI-'DU.COEOVlOOC5COOO0CCCOOcCC:0OCOEIDOCC).'OCiCCJJJC)UCJ805COCJ8)LuO)ECJI-?'OOK100101102103105UcensedECSTANLOPS/SEC/FirstAidResponderDCSEmergencyCoordinatorTSCSupenrisorTSCHPSupervisorTSCChem.SupenrisorTSCReactorEngineerXXGG*XGG'GG'XXXXXX'XXXXXXXXXGXX=C=RequiredRespiratorOnlyIndudedinEROActivationtrainingforDCSonly:AutodialerJPMWrittenexamSimulatorpracticesessionwithE-PlaneventsIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSL/PTNCommonResponderVersionG=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPoolD=IndudedinEmerg.Rad.Monitoring/R9
~-REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:22of38ATTACHMENT2EROINITIALTRAININGMATRIX(Page2of9)ERO¹106107108109110'tie111112113114POSITIONTSCCommunicatorTSCEMPSTRep.TSCMMPSTRep.HPShiftSupervisorTSCOPSCoordinatorTSCDoseAssessorTSCHPCommunicatorTSCSPPhonetalkerTSCERDADSOp.0CCCo0C0ELUX'0r0O.Ku0IU'0C0O.KOCOI-XEI-OLO0GGGGGGGC08OELUC080K0CELUC0CC0KLUCIC00000CCCCClCOCCI0K0O.coI-08LO0OOP.O000'DccELUX0O.0r/I0OKLUECllI-LKCCELOC0CCCClOO0CC0CC0'0C0OCClE0O0000'0CCLO0uCll00CC5C0CC8LUE0CiI-0LL:XCRequiredRespiratorOnlyincludedinEROActivationtrainingforDCSonly:AutodialerJPMWrittenexamSimulatorpracticesessionwithE-PlaneventsIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSL/PTNCommonResponderVersionG=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPoolD=IncludedinEmerg.Rad.Monitoring/R9 REVISIONNO.:PROCEDURENo.:EPIP-12PROCEDURETITLEMAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:23of38ATTACHMENT2EROINITIALTRAININGMATRIX(Page3of9)116116117118POSITIONTSCPSTLeaderTSCERDADSTechTSCl&CPSTRep.TSCSROPSTRep.00CC5o.ELU'8C00.Ku0LUL0'0C00.K0LOI-EC$I-OLo0GGGC08NC5O0ELUC080Z0COlELUC0cd.)0KILIL0O'8)0KK'5I-0(5C8V)C70OECVE000OC000O.0coOOKLU(hECOLOC0CO0OO0ei00C00COEOC0600CI0)LneuT)c4C00C0c58C5IUCbCC$I-0)?'00KX.1191201211241stTSCSecuritySupv.TSCCoord.viithOSCTSCAdminStaffTSCECAssist/Log.OSCHPTech.GGGXGGXXXCRequiredRespiratorOnlyIncfudedinEROActivationtrainingforDCSonly:AutodialerJPMWrittenexamSimulatorpracticesessionwithE-PlaneventsIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSL/PTNCommonResponderVersionG=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPoolD=IncludedinEmerg.Rad.Monitoring/R9 REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:24of38ATTACHMENT2EROINITIALTRAININGMATRIX(Page4of9)ERO¹152157158159160POSITIONOSCEMRe-EntrySupv.OSCl&CRe.EntrySupv.OSCMMRe-EntrySupv.OSCChem.Supv.OSCElectricalChiefOSCSupervisorOSCCoord.viithTSCOSCHPSupv.OSCChemist000Cdo00ELUX'0C00.Ku.0LU'8C0Q.K0LOI-EI-0v)0XXGGGGGGGC0OCdCCCCd0CJ00Ol0EulCdC080zCl0CdpdlELUC0Cd0CCLUd)000L000CC0LOI-0CCdCClClLOdl00IOL00OlC0C0'0CdKCl0tDOl0ELUCd00CdCd0.0v)OOKulEI-LuE0v)C0'ClCdCd)0O0COC0'000CdEdl0Cdl'0X'0CdOlcou.2.ZCdC8D5C0Cd0CdLUOlCCdI-COl?'0dlCCXCRequiredRespiratorOnlyIncludedinEROActivationtrainingforDCSonly:AutodialerJPMWrittenexamSimulatorpracticesessionviithE-PlaneventsIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSL/PTNCommonResponderVersionG=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPoolD=IncludedinEmerg.Rad.Monitoring/R9 0-REVISIONNO.:PROCEDURENo.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:25of38ATTACHMENT2EROINITIALTRAININGMATRIX(Page5of9)ERO¹161POSITIONOSCElectrician00CCiK0CNLll'OC00.KU.0Ul'0C0Q.LL:OV)I-EOVl0XGGC08gO0EUlC080z0C0ELuC0CO0fhC00)0C00K0LOI-0C$C8Vl0000CdCOECOO0000)0C0COLL:0C0Ol0EUlC00.0VIOOccLuCOECOLOC0diOO0(dC0C00O00d)C$OiLQ0UZlCO805C0Cl8UlCcdI-IOi)000K162163165166168OSCMechanicOSCl&CSpec.XOSCOn-ShiftSecuritySpec.XOSCDosi.Tech.OSCMMForemanXGXGXGXGXGG169170OSCNMMStaffRep.OSCSafetyRep.XXGXGXCRequiredRespiratorOnlyIndudedinEROActivationtrainingforDCSonly:AutodialerJPMWrittenexamSimulatorpracticesessionviithE-PlaneventsIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSUPTNCommonResponderVersionG=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPoolD=IncludedinEmerg.Rad.Monitoring/R9 REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:26of38ATTACHMENT2EROINITIALTRAININGMATRIX(Page6of9)ERO¹POSITION0COKOCElu3.K0LLIC0KOv)I-EI-Ovl0L0C(0NC$OOCELLIi:0-8OZOCELuC0cL0LuCOCOOLOO'8)KOv)I-0CCLi3v)OO0OOF0EO'OKOCEluOQ.0v)OOKLuCOEC>v)0C$COO0COCOIDCOC0OCOEIDOC'OC5OlLOeuJ5CLCD0centLOC58ct5ILIC7IEC5I-CZi0OC)K171OSCAdminTech/Log.172AssemblyAreaSupv.173OSCOPSRe-EntrySupv.174OSCProtandControlRep175OSCINCShopSupv.176FieldMonTeamDriver177OSCInfoServicesRep.200RecoveryManager205Govt.AffairsMgr.XXXXGGGGGGGG/CHXCRequiredRespiratorOnlyIncludedinEROActivationtrainingforDCSonly:AutodialerJPMWrittenexamSimulatorpracticesessionwithE-PlaneventsIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSL/PTNCommonResponderVersionG=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPoolD=IncludedInEmerg.Rad.Monitoring/R9
-REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLEMAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:27of38ATTACHMENT2EROINITIALTRAININGMATRIX(Page7of9)ERO¹209213216230231232POSITIONEOFRMOPSAdv/Log.EOFERDADSOp.EOFStatusBoardKeeperEOFEmergTechnicalMgrEOFProjectEngineerEOFMech.Engineer0Co.EUJKK0UJXRK0I-VJEIK0VJ0HC08C$00EUJCOC080z0El0ELJJC0el)0KUJIhC000000OCOIOClIOC0'0K0O.V)I-0'Cc5C3VJ0000OP00C'C0CKELuC0O.0LOOOKLuCOEC)V)C0CJC00O0CIIC00C000C0'0'0IIJOJLJ)BU.CIJ8c5C0OLJJ0)CCIllI-00K233235236EOFNuclearEngineerEOFNucFuelsEng.EOFCivilEngineerXXXXCRequiredRespiratorOnlyIncludedinEROActivationtrainingforDCSonly:AutodialerJPMWrittenexamSimulatorpracticesessionwithE-PianeventsIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PStJPTNCommonResponderVersionG=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPoolD=IncludedinEmerg.Rad.Monitoring/R9 0-REVISIONNO.:PROCEDURENo.:EPIP-12PROCEDURETITLEMAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:28of38ATTACHMENT2EROINITIALTRAININGMATRIX(Page8of9)ERO¹POSITION00CCIo.000p0Elu'8C00KU.0UJ3.KOIIOEIOIO0OKC0-8CCIO0C0P0EUJCO0080z0CO)0EUlC0CCCCl0KUJC0b5L-0O)K00.IO0'0CCi3IOQ0O0Q0O0)00C0CCIK000)0EUJC0O.0IOOOKUJCCiECOco00CCI0OO0CCi000'0C0O2OC0J5CCIC0005C0CCI0Cl$UJECCCII-Ol000K237EOFIKCEngineer238EOFElectricalEngineer240EOFHPManager245EOFDosAssessor/FMT246EOFHPTechSupport247EOFRadStatBdsKeeper250EOFNuc.Uc.Mgr.255EOFCommunicator260Emerg.SecurityMgr.XXXXXXXXXXXXXXXXXXHXXXXXXXCRequiredRespiratorOnlyIndudedinEROActivationtrainingforDCSonly:AutodialerJPMWrittenexamSimulatorpracticesessionwithE-PlaneventsIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSL/PTNCommonResponderVersionG=Training/RequalFrequencyIAWotherPlantProceduresH"-FFDPoolD=IncludedinEmerg.Rad.Monitoring/R9
~-REVISIONNo.:PROCEDURENO.:EPIP-12PROCEDURETITLEMAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:29of38ATTACHMENT2EROINITIALTRAININGMATRIX(Page9of9)ERO¹270POSITIONEOFEmergInfoMgr.?0CCdKCdEIJJC0O.KU.0UJO00Q.IJ:OrrJI-EI-?'r.OcrJ0C0Cd0CdCdCdOEIu~dC00zEIJJC0Cd0IJ:UJ0000L0OCd'0'608rrJ00O00E0OOi0'0000CdIJ.00dlPCdEUJC0O.00JOOIJ:IJIrnC0ccrOO0Cd00'0Cd0OCdEdl0C0CdCd'0rnClU.T78C0Cd8)UJOr0EI-F0CdK271273280281291294295NDDOEIM/ENCTechAdvisorEOFAdminSupervisorEOFAdminStaffGovernor'sAdvisorSt.LucieCoTechAdvMartinCoTechAdvEmerControlOfficerEEEEXCRequiredRespiratorOnlyIncludedinEROActivationtrainingforDCSonly:AutodialerJPMWrittenexamSimulatorpracticesessionviithE-PlaneventsIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSL/PTNCommonResponderVersionG=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPoolD=IncludedinEmerg.Rad.MonitoringENDOFATTACHMENT2 REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:30of38ATTACHMENT3EROANNUALREQUALIFICATIONMATRIX(Page1of9)ERO¹101102103POSITIONLicensedECSTANLOPS/Sec/FirstAidResponderEmergencyCoordinatorTSCSupervisorTSCHPSupervisorOC5'OC1.DCiCCOI-LOCSO.COOO0C$'OC1.DC5OOGG*GGGGGC0OELuCO8O2:fELuC0OOO0O(hCO'6OCCCOOLOIDOOOCoEOC$EOOOOO)OCOKELu0OO.0COOQKLLLECOOI-'OLii.G'ChECOLnCOC$EOOO0OOC002OCC7O'Li'OCiOlLnClii.G*OlCI-8K105106TSCChem.SupervisorTSCReactorEngineeringTSCCommunicatorGGGXGX=RequiredC=RespiratorOnlyIfqualiTiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PStJPTNCommonResponderVersionF=SAMGRequalFrequencyIAWADM-11.11G=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPool/R9 REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:31of38ATTACHMENT3EROANNUALREQUALIFICATIONMATRIX(Page2of9)ERO¹POSITIONO'KO0U0Uj8OKC08COO0CJJEUJC08I0zfEtuC0OLC)0ON0CO000CSCCl0rnC7Cl0OOe0OCC0C0'0K00.0coOOCCluEI-'DzKCOEClCOV)C0CJOO0C00'0C0OEC)OCCl'06C)'0C$CCrnK0)C2I-8K107TSCEMPSTRep.108TSCMMPSTRep.110TSCOPSCoordinator111TSCDoseAssessor112TSCHPCommunicator113TSCSPPhonetalker114TSCERDADSOp.115TSCPSTLeader116TSCERDADSTechXGGGXX=RequiredC=RespiratorOnlyIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSL/PTNCommonResponderVersionF=SAMGRequalFrequencyIAWADM-11.11G=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPool/R9
~.REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:32of38ATTACHMENT3EROANNUALREQUALIFICATIONMATRIX(Page3of9)ERO¹POSITIONC$'00.DC$000I-IOCi0.C$O$$$0Ci40.DC$U.0IuC08C$OEIu080zEUIC0Ci0LCi0Og4'60'0C$CC70IOC$00OO00F000C$KEUIC00.0$OO0IZUIC$EEOIO0C$OO0C0C00EC$0'I10C$O$coClII0$EEC$I-117TSCl&CPSTRep.118TSCSROPSTRep.119TSCSecuritySupv.120TSCCoord.withOSC121TSCAdminStaff124TSCECAssist/Log.151OSCHPTech.152OSCEMRe-EntrySupv.153OSCI&CRe.EntrySupv.XGGGGGGGGGXXX=RequiredC=RespiratorOnlyIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSL/PTNCommonResponderVersionF=SAMGRequalFrequencyIAWADM-11.11G=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPool/R9 REVISIONNo.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:33of38ATTACHMENT3EROANNUALREQUALIFICATIONMATRIX(Page4of9)EROff155156157158159161162POSITIONOSCMMRe.EntrySupv.OSCChem.Supv.OSCElectricalChiefOSCSupervisorOSCCoord.withTSCOSCHPSupv.OSCChemistOSCElectricianOSCMechanicCCCDCCC0COV)I-ClCCI'00.DciCO0GGGGGGGGGGGGC0OCOC00ZLEtuC0000OCllCOC0'0O0'0CCCC:00V)C)0OEg0E0O0lC0E0CCC00.0roOOKtuE0I-'D8KCOECOroC0C50OO0C0EjC0O?'CCl'06CJG'i)ci0l6)0Ii0lECCCII-0l0)C)KX=RequiredC=RespiratorOnlyIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSUPTNCommonResponderVersionF=SAMGRequalFrequencyIAWADM-11.11G=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPool/R9
-REVISIONNo.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:34of38ATTACHMENT3EROANNUALREQUALIFICATIONMATRIX(Page5of9)ERO¹165168169170171172POSITIONOSCl&CSpec.OSCOn-ShiftSecurity(Spec.)OSCDosi.Tech.OSCMMForemanOSCNMMStaffRep.OSCSafetyRep.OSCAdminTech/Log.AssemblyAreaSupv.C)CODc4c0CO0CIc5OQ.DCODCu.0uj3<<COKGGCO8CO05C5C)EuJCO.8OzEtuLO05'D0O0'i-CiCC)OroCPe00EgOP00C0'DcdKEUJC0c5O.0COO<<COKluCOECOV)Oc5Cl0O0C:0C);oC00E0CID6'Dc5CDrnC)KX=RequiredC=RespiratorOnlyIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSUPTNCommonResponderVersionF=SAMGRequalFrequencyIAWADM-11.11G=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPool/R9 0REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:35of38ATTACHMENT3EROANNUALREQUALIFICATIONMATRIX(Page6of9)ERO¹POSITIONcJ'DO.DYsC0CO'oQ.DCOaO0C)Y$'DCl.DC$Diu0tuC0OZEluC0oOClt=OOCii)OC4CCPOV)e00C5C5EO000O)COCOcdILOCiDPEuJC:0hCL0U)0OKUJiiiEMi0C$CCiOO0COCl'DCOOOCC):Z7'6'UCOO)'a6)LiiiiOlCCCgI-Ol?'oK173OSCOPSRe-EntrySupv.174OSCProtandControlRep175OSCl&CShopSupv.176FieldMonTeamDriver177OSCInfoServicesRep.200RecoveryManager205Govt.AffairsMgr.209EOFRMOPSAdv/Log.213EOFERDADSOp.XGGGGX=RequiredC=RespiratorOnlyIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSUPTNCommonResponderVersionF=SAMGRequalFrequencyIAWADM-11.11G=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPool/R9 REVISIONNO.:PROCEDURENo.:EPIP-12PROCEDURETITLEMAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:36of38ATTACHMENT3EROANNUALREQUALIFICATIONMATRIX(Page7of9)ERO¹POSITION0c5'0Q.DC5C000Ci0Q.DC5CC08c500O>0EUJCO000ZEtuC00L00m0CCi0M000OP00cc00'0CiccIUjC0Q.0roO<<COrt:luCOECOV)Q0CSC00O0CCC0C00E00C0600'0C5CCClCIIiOiE(5I-IOl00K216EOFStatusBoardKeeper230EOFEmergTechnicalMgr231EOFProjectEngineer232EOFMech.Engineer233EOFNudearEngineer235EOFNucFuelsEng.236EOFCivilEngineer237EOFI8CEngineer238EOFElectricalEngineerX=RequiredC=RespiratorOnlyIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaXE=PSUPTNCommonResponderVersionF=SAMGRequalFrequencyIAWADM-11.11G=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPool/R9 REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLEMAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:37of38ATTACHMENT3EROANNUALREQUALIFICATIONMATRIX(Page8of9)ERO¹POSITIONOCDOCLDCDOI-roO0CD'OO.DCDCC0CDCDUOCEruCD0CDOOCDOEulCDO0CDI=CDOOCDCOOC3OCDCOOOOPO0C0EO'Orr.EruCOECL0coODri:ujEI-'CDLII.CDECDCDrnCOCDCCDOO0CDCOCflO0ECDOCD'OOCD'OCDCÃlaIneuCDEEI-rr240EOFHPManager245EOFDoseAssessor/FMT246EOFHPTechSupport247EOFRadStatBdsKeeper250EOFNuc.Uc.Mgr.255EOFCommunicator260Emerg.SecurityMgr.270EOFEmergInfoMgr.271NDDOXXXXXXXXX=RequiredC=RespiratorOnlyIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriaE=PSL/PTNCommonResponderVersionF=SAMGRequalFrequencyIAWADM-11.11G=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPool/R9 0REVISIONNO.:PROCEDURENO.:EPIP-12PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-RADIOLOGICALEMERGENCYPLANTRAININGST.LUCIEPLANTPAGE:38of38ATTACHMENT3EROANNUALREQUALIFICATIONMATRIX(Page9of9)EROIfPOSITIONOCi'QQ.DCiQOCO'QQ.Dc4QO0O'OQ.DC5QQu.0ILLC08Ci0ClEILICO8OZELLIC0OOOI=OO'QOC5QOIOOO00OOO0O)OC0Oc5LL:OOCCELLLQOOQ.0COOOLL:LuCOEO(0IOC0tt$OQ0COO'OC0O20Cl'6CCECCiI-CCO0OK273EIM/ENCTechAdvisor280EOFAdminSupervisor281EOFAdminStaff291Governor'sAdvisor294St.LucieCoTechAdvisor295MartinCoTechAdvisor300EmergencyControlOfficerXHXHXHXHXHEHX=RequiredC=RespiratorOnlyIfqualifiedtoholdshiftposition,ThenpositionmeetsEROqualificationcriteriE=PStJPTNCommonResponderVersionF=SAMGRequalFrequencyIAWADM-11.11G=Training/RequalFrequencyIAWotherPlantProceduresH=FFDPool//R9ENDOFATTACHMENT3 Title:FPLST.LUCIEPLANTEMERGENCYPLANIMPLEMENTINGPROCEDURESAFETYRELATEDProcedureNo.EPIP-13CurrentRev.No.5EffectiveDate:12/20/00MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSResponsibleDepartment:EMERGENCYPREPAREDNESSRevisionSummaryRevision5-AddedquarterlytestforERDSlinkandreferencetoGenericLetter¹GL93-01.(J.R.Walker,12/07/00)ANDDeletedreferencetoPSLpolicyPSL-110,revisedFRGreviewofEPIPs,changedthesymbolofresponsetoCROO-0544fromregulatorycommitmenttomgmtdirectiveandaddedEPIP-08tothelistofEPIPs.(J.R.Walker,10/13/00)Revision4-AddedstaffaugmentationprogrammaintenanceitemsandNRCperformanceindicatortracker.(D.Calabrese,04/27/00)Revision3-ChangedresponsibilityforEPfromTrainingManagertoProtectionServicesManager.ImproveddefinitionfordrillperE-Plan.Correctedeval.exercisefrequencyfromannualtobiennialperE-Plan.Correctedrecoveryplanreviewfrequency.Correctedreviewofannualtraining.CorrectedprocedurenumberandtitleofupgradedE-Planchemistryprocedures.CorrectedexcritiquereviewfromTrainingManagertoFRGperE-Plan.Madeeditorialandadministrativechanges.(J.R.Walker,06/17/99)PSLRevision2-MinorCorrectionspage18,C-110changedtoCOP-06.toCOP-06.11.(RussCox,06/01/99)6wn6C=I+1CITYedOOPROCEDUREPIKHXJCTIONRevisionFRGReviewDate012/15/97RevisionFRGReviewDate12/07/00ApprovedByJ.ScarolaPlantGeneralManagerApprovedByR.G.WestPlantGeneralManagerN/ADesignatedApproverApprovalDate12/15/97ApprovalDate12/07/00SOPSDATEDOCTPROCEDUREDOCNEPIP-13sYsCOMPCOMPLETEDITM5
REVISIONNo.:PROCEDURENo.EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTTABLEOFCONTENTSPAGE:2of35SECTIONPAGE1.0PURPOSE~~~00~~~~~~~~~~~~~~~0~~
32.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTS32.1References......~..............................~.32.2RecordsRequired...................~..~~~......~..42.3CommitmentDocuments....~..........~~.~~...~~~...43.0RESPONSIBILITIES4.0DEFINITIONS...~...~~~~~~~~~~~~~~~~~~~4~~~~~~~~~~~~~~~~~~~65.0INSTRUCTIONS~..~............~..~~~..,~....~...~~.~~95.1ProtectionServicesManagerInstructions...~...~~~..~....~95.2EmergencyPreparednessSupervisor~.......~~~.~~..~~~11DATASHEETSDATASHEET1EPPROGRAMMAINTENANCECHECKLIST........13DATASHEET2EMERGENCYPLAN6YEARELEMENTDEMONSTRATION...........~...~...~~....~.16DATASHEET3EPIPBIENNIALREVIEW~..17DATASHEET4EPEXERCISECHECKLIST..~......~~~.~...~..19ATTACHMENTATTACHMENT1EPPROGRAMSCHEDULE.~~..~~~~~~~~~~~20 REVISIONNo.:5PROCEDURENO.:EPIP-131.0PURPOSEPROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTPAGE:3of35Thisprocedureprovidesinstructionsfor:PeriodicexercisesanddrillsconductedinordertotestthestateofemergencypreparednessbyFPLpersonnel,supportorganizationsandoff-sitegovernmentalagencies.PeriodictestsandreviewsofcomponentsoftheEmergencyPlanningProgram(e.g.facilities,equipment,EmergencyPlanandEmergencyPlanImplementingProcedures,etc.)conductedtoensureavailability,operabilityandreliability.
2.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTSNOTEOneormoreofthefollowingsymbolsmaybeusedinthisprocedure:gIndicatesaRegulatorycommitmentmadebyTechnicalSpecifications,ConditionofLicense,Audit,LER,Bulletin,etc.,andshallNOTberevisedwithoutFacilityReviewGroupreviewandPlantGeneralManagerapproval.Indicatesamanagementdirective,vendorrecommendation,plantpracticeorothernon-regulatorycommitmentthatshouldNOTberevisedwithoutconsultationwiththeplantstaff.2.1References1~St.LuciePlantRadiologicalEmergencyPlan(E-Plan)2.Ql1-PR/PSL-1,SiteOrganization3.Ql-1-PSL-15,ProtectionServicesOrganization4.QI-5-PSL-1,Preparation,Revision,Review/ApprovalofProcedures.5.QI-17-PSL-1,QualityAssuranceRecords6.NBS-NPS-EP-WP-001,PublicAlertandNotificationSystemTesting,MaintenanceandEngineering7.ADM-25.02,NRCPerformanceIndicators REVISIONNo.:PROCEDURENo.EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTPAGE:4of3
52.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTS(continued)2.2RecordsRequired1~ThefollowingrecordsaremaintainedinaccordancewithQl-17-PSL-1QualityAssuranceRecords:2.DataSheet1,EPProgramMaintenanceChecklist3.DataSheet2,EmergencyPlan6YearElementDemonstration4.DataSheet3,EPIPBiennialReview5.DataSheet4,EPAnnualExerciseChecklist6.Attachment1,EPProgramSchedule2.3CommitmentDocuments1.10CFR50,DomesticLicensingofProductionandUtilizationFacilities2.GenericLetter¹GL93-01,EmergencyResponseDataSystemTestProgram/R53.PMAI¹96-02-237,EvaluationofContinuousEmergencyResponse4.NOVResponseL-97-20,ViolationII.A,Part4.D./R55.CR00-0544,QAAudit(IneffectiveCorrectiveActions)QSL-EP-00-023.0RESPONSIBILITIESg,3.1TheProtectionServicesManagerisresponsiblefor:1.Planning,scheduling,andcoordinatingemergencyexercisesinvolvingoff-siteagencies.2.ReviewingAttachment1,EPProgramSchedule,uponcompletion.3.Reviewingresultsofexercisesandmajordrills.
REVISIONNo.:PROCEDURENo.:EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTPAGE:5of353.0RESPONSIBILITIES(continued)g,3.2TheProtectionServicesManager,inconjunctionwithplantmanagement,isresponsibleforensuringthatadequateresourcesaremadeavailabletosupportandconductemergencypreparednessactivitiesincluding:1~Exerciseanddrillscenariodevelopmentandcontrol2.Exerciseanddrillparticipation3.Supportformaintenanceofemergencyfacilitiesandequipmentg,3.3TheFacilityReviewGroup(FRG)isresponsibletoreviewthefollowing:1~RevisionstotheSt.LuciePlantRadiologicalEmergencyPlan./R5/R52.RevisionstoEmergencyPlanImplementingProcedures(EPIPs)otherthanminorchanges./R53.BiennialExerciseCritiqueReport.3.4TheEmergencyPreparedness(EP)Supervisorisresponsiblefor:MaintainingawarenessofEPactivities.2.EnsuringcoordinationofEPdrillsandexercisesinaccordancewiththisprocedure.3.EnsuringdocumentationofEPprogrammaintenanceinAttachment1,EPProgramSchedule.4.EnsuringdocumentationofmajorelementdemonstrationasindicatedonDataSheet2,EmergencyPlan6YearElementDemonstration.5.Ensuringcritiquesofexercises,drills,andactualeventsareconducted,documented,andthatdeficienciesareaddressedinaccordancewithplantcorrectiveactionpractices.
REVISIONNO.:5PROCEDURENo.:EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTPAGE:6of353.0RESPONSIBILITIES(continued)3.4TheEmergencyPreparedness(EP)Supervisorisresponsiblefor:(continued)6.EnsuringthatEPIPsarereviewedthroughfeedbackfromthefollowingsources:A.DailyuseB.DrillsandexercisesC.ActualeventsD.TrainingE.BiennialEPIPreviewasindicatedonDataSheet3,EPIPBiennialReview7.EnsuringbiennialreviewoftheRecoveryPlan.4.0DEFINITIONS4.1Annual-Annualisdefinedasoncepercalendaryear(January1throughDecember31).4.2Biennial-Biennialisdefinedasoncepertwocalendaryears.4.3Drill1.CommunicationsTestsandDrills-Communicationstestsinvolvetheuseofemergencycommunicationsequipmenttoverifyoperability.Communicationsdrillsinvolveuseofemergencycommunicationsequipmenttonotifyandtransfersimulatedemergencyinformationtooff-sitegovernmentalagencies.2.HealthPhysicsDrills-HealthPhysicsdrillstestvarioustasksemployedbythatdepartmentduringanemergencycondition.HealthPhysicsdrillsareconductedsemi-annuallyandoneofthesemi-annualdrillsmaybeincorporatedintotheradiologicalmonitoringdrill~
REVISIONNo.:PROCEDURENo.:EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTPAGE:7of354.0DEFINITIONS(continued)4.3Drill(continued)3.MedicalEmergencyDrill-Amedicalemergencydrillinvolvesasimulatedcontaminatedindividual,withprovisionsforactivationoftheplantFirstAid/PersonnelDecontaminationTeam.Participationbylocalsupportservices(i.e.,ambulanceandoff-sitemedicaltreatmentfacility)istestedseparatelyonceperyearoraspartoftheannualmedicaldrill.MedicalEmergencyDrillsareconductedatleastonceeverycalendaryear.4.RadiologicalMonitoringDrill-Radiologicalmonitoringdrillsincludecollectionandanalysisofairsamples,testingofcommunications,andunderstandingofmessagesbetweenHealthPhysicssupervisionandtheoff-sitemonitoringteams.Aradiologicalmonitoringdrillwillbeconductedatleastonceeverycalendaryear.5.EmergencyResponseFacility(ERF)Drill-AnERFDrilldemonstratesvariousemergencyresponsecapabilitiesincludingmanagementandcoordinationofemergencyresponse,accidentassessment,protectiveactiondecision-making,andplantsystemrepairandcorrectiveactioninvolvingallorcertainEmergencyResponseFacilities[ControlRoom,TechnicalSupportCenter(TSC),OperationalSupportCenter(OSC),EmergencyOperationsFacility(EOF),and/orEmergencyNewsCenter(ENC)].Thesedrillsareconductedatleastfour(4)timespercalendaryearandshouldbeconductedapproximatelyonceeachcalendarquarter.Oneofthesedrillsisdesignedtosatisfytherequirementsofanexerciseasdefinedbelow.Non-exercisedrillsprovideanopportunitytoconsideraccidentmanagementstrategies.Supervisedinstructioncanbepermittedforthesedrills,withoperatingstaffhavingtheopportunitytoresolveproblems(successpaths)ratherthanhavecontrollersintervene.Additionally,non-exercisedrillsmayfocusonon-sitetrainingobjectives.
REVISIONNo.:PROCEDURENo.EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTPAGE:8of354.0DEFINITIONS(continued)4.4Exercise-AnexerciseisaneventthatteststheintegratedcapabilityofamajorportionofthebasicelementsexistingwithintheSt.LuciePlantRadiologicalEmergencyPlan.Anexerciseisrequiredbienniallyper10CFR50.Off-siteagencyparticipationisrequiredbiennially.Exercisesaredeveloped,scheduled,andconductedinamannerconsistentwiththeregulationsandguidanceof10CFR50AppendixE,NUREG0654,andotherappropriateregulatorydocuments.Biennialexercisesinvolvingoff-siteagenciesshallbeconductedasaSiteAreaEmergencyandshouldescalatetoGeneralEmergency.TheexercisescenariosarevariedsuchthatallmajorelementsofthePlanaretestedatleasteverysix(6)years.4.5LetterofAgreement(LOA)-SupportorassistancefromoutsideagenciesisestablishedandmaintainedthroughLettersofAgreementor,insomeinstances,purchaseorders/contracts.LettersofAgreementareconfirmedannuallythroughcorrespondence,directcontact,orbytelephone.Eachagreementisrenewedatleasteverythree(3)years.Purchaseorders/contractsarerenewedasrequired.4.6Monthly-Monthlyisdefinedasatleastonceeachcalendarmonth,beingthefirstdayofeachmonthuntilthelastunlessotherwisespecified.4.7Quarterly-Quarterlyisdefinedasoncepercalendarquarter,withthequartersbeingJanuarythroughMarch,AprilthroughJune,JulythroughSeptemberandOctoberthroughDecember.4.8Semi-annual-Semi-annualisdefinedastwicepercalendaryear,withonetimefromJanuary1toJune30andonefromJuly1toDecember31.
REVISIONNo.:PROCEDURENo.:EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTPAGE:9of355.0INSTRUCTIONS5.1ProtectionServicesManagerInstructions1~ReviewcompleteddocumentationofAttachment1,EPProgramSchedule,onanannualbasis.2.EnsurethatStateandCountyEmergencyManagementofficialsaremadeawareofnon-emergencyeventsthathaveapotentialformediainterest.A.InformEmergencyPreparedness(EP)ofeventB.VerifythatEPhasinformedappropriateEmergencyManagementofficials.3.EnsurethatStateandCountyEmergencyManagementofficialsaremadeawareofthefollowingonanannualbasis:A.SignificantchangestotheEmergencyPlan/EPIPs.B.EmergencyActionLevels(EALs)4.MaintainawarenessofthestatusoftheAlertandNotificationSystem(ANS)operability.A.EnsurethatEPupdatesthisinformationonthePlantDailyStatusReport.B.EnsurethatdegradationsoftheANSarepromptlyaddressed.TheManager,PlantServicesisresponsibletomaintainoperabilityoftheANSperNBS-NPS-EP-WP-001,AlertandNotificationSystemTesting,MaintenanceandEngineering.
REVISIONNO.:PROCEDURENo.:EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTPAGE:10of355.0INSTRUCTIONS(continued)5.1ProtectionServicesManagerInstructions(continued)5.Ensurethefollowingisperformedinsupportofexercises:A.ScheduleadatefortheexerciseincoordinationwiththeprimaryStateandCountyemergencyresponseagencies.B.ProvidetheopportunityforStateandCountyresponseagenciestoparticipateinanexercise.C.CoordinateFPLeffortswithotherparticipatingpersonnel,organizations,andagencies.IftheFederalEmergencyManagementAgency(FEMA)isevaluatingStateandCountyemergencyresponse,Thenensurethattheexercisescenarioisdevelopedwithinthetimeframesspecifiedbytheregulations,asdefinedinDataSheet4,EPAnnualExerciseChecklist.D.Discussandevaluateannualexerciseperformancewithplantmanagement,FPLcontroller/evaluatorsandprincipalparticipants.ENDOFSECTION5.1 REVISIONNo.:PROCEDURENo.:EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTPAGE:11of355.0INSTRUCTIONS(continued)5.2EmergencyPreparednessSupervisor1~Atthebeginningofeachcalendaryear:A.ScheduletheitemsonDataSheet1,EPProgramMaintenanceChecklist.B.RecordonDataSheet2,EmergencyPlan6YearElementDemonstration,thedataofthemostrecentperformance.Ensuretheyearlastperformeddateislessthan6yearsfromthecurrentyear.C.ScheduleadditionalelementstobeperformedthisyearasnecessaryonAttachment1,EPProgramSchedule(Item7).D.ScheduleprocedurereviewsfromDataSheet3,EPIPBiennialReviewonAttachment1,EPProgramSchedule.2.MaintainawarenessofstatusofcompletionofAttachment1,EPProgramSchedule.A.Responseactionsperformedaspartofactualplantemergenciesmaybecreditedtowardsthefollowingdrillsortests:integratedfacilityactivationdrillcalloutphonetest/drillHPdrilloff-siteagencycommunicationsdrillmedicaldrillB.Evolutionsincorporatedwithinamultiplescopedrill/exercisemaycountasdrillortestcompletion,asexample:HPdrill,medicaldrill,oroff-sitecommunicationsdrillaspartofquarterlyintegratedfacilityactivateddrillorannualexercise.
REVISIONNo.:PROCEDURENO.:EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTPAGE:12of355.0INSTRUCTIONS(continued)5.2EmergencyPreparednessSupervisor(continued)2.(continued)C.OffHoursAugmentationincluding:/R5~weeklytestsofautomatedrecallsystem~quarterlyoff-hoursphonetest(atleastoneperyearshouldbemanual)~monthlyreviewofEmergencyResponseDirectory~quarterlyverificationofEmergencyResponseDirectorydata~quarterlyverificationofEmergencyResponseDirectorydistributionlist~quarterlypublicationanddistributionofEmergencyResponseDirectoryD.NRCPerformanceIndicators~prepareandsubmitinaccordancewithADM-25.013.EnsurethecompletionoftheitemsonDataSheet2,EmergencyPlan6YearElementDemonstration.4.EnsurethecompletionoftheitemsonDataSheet3,EPIPBiennialReview.5.EnsurethecompletionoftheitemsonDataSheet4,EPAnnualExerciseChecklist.ENDOFSECTION5.2 REVISIONNo.:PROCEDURENO.EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTDATASHEET1EPPROGRAMMAINTENANCECHECKLIST(Page1of3)PAGE:13of35Semi-Annual/Annual/BiennialEPMaintenanceItems:g,1.HPDrill(Semi-Annual)A.(Jan-Jun)Date/~B.(Jul-Dec)Date~~g,2.RadiologicalMonitoringDrill(Annual)A.Datej~BiennialExercise(IncludeDataSheet4,EPExerciseChecklist)A.Datej~B.FEMAEvaluated(EvenYearsOnly)Yes/Ncg,4.AnnualOffsiteAgenciesCommunicationsDrillA.Date~~g,5.AnnualUnannouncedCommunicationsDrillA.Date~/Q,6.AnnualMedicalDrillA.Date~~(YEAR)INITIAL/DATESOPSDATEDOCTCHECKLISTDOCNEPIP-13sYsCOMPCOMPLETEDITMREV REVISIONNO.:PROCEDURENo.:EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTDATASHEET1EPPROGRAMMAINTENANCECHECKLIST(Page2of3)PAGE:14of35(YEAR)Semi-Annual/Annual/BiennialEPMaintenanceItems(continued):INITIAL/DATEg,7.EmergencyPlanReview:A.EmergencyPlanReview(Annual)B.LettersofAgreementCertification(AnnualConfirmation/TriennialRenewal)C.EPIPReview(Evenyearsonly)(IncludeDataSheet3,EPIPBiennialReview)g,8.MediaDay(Annual)g,9.PublicInformationBrochure(Annual)10.ReviewandupdateSixYearPlan(Annual)(IncludeDataSheet2,EmergencyPlan6YearElementDemonstration)g,11.SignificantEmergencyPlan/EPIPChanges,EmergencyActionLevels(EALs)MeetingwithState/CountyEmergencyManagement(Annual)g,12.HospitalTraining(Annual)g,13.Off-siteTraining(Annual)14.RecoveryPlanReview(Biennial)
REVISIONNO.:PROCEDURENO.EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTDATASHEET'IEPPROGRAMMAINTENANCECHECKLIST(Page3of3)PAGE:15of35(YEAR)Semi-Annual/Annual/BiennialEPMaintenanceItems(continued):INITIAL/DATE15.AnnualtrainingreviewofEROA.SolicitverificationofannualEROtrainingcompletionfromtheTrainingDepartment.B.ReviewtrainingcompletionfeedbackandremoveanyEROmembersnotqualified.16.EPProgramMonthlySchedule(Attachment1,EPProgramSchedule)CompletedbyEmergencyPreparednessSupervisorReviewedbyProtectionServicesManagerENDOFDATASHEET1 REVISIONNo.:PROCEDURENO.EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANT.,PAGE:16of35DATASHEET2EMERGENCYPLAN6YEARELEMENTDEMONSTRATIONYEARElementOffhoursstaffing(6P.M.-4A.M.)ActivationofEmergencyNewsCenterUseoffirecontrolteamsUseofmedicalsupportpersonnelUseofSecuritypersonnelforpromptaccesstoemergencyequipmentorsupportUseofoneormoreportionsofbackupcommunicationsfornotificationFieldmonitoringCapabilityfordeterminingthemagnitudeandimpactoftheparticularcomponentsofareleaseCapabilityforpost-accidentcoolantsamplingandanalysisAssemblyandaccountabilityInitialrecoveryplanningactivitiesYearLastPerformedYearNextScheduledDateCompletedlInitialENDOFDATASHEET2 REVISIONNo.:PROCEDURENO.EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTDATASHEET3EPIPBIENNIALREVIEW(Page1of2)PAGE:17of35(YEAR)I.EmergencyPlanImplementingProcedures(Biennial)EPIP-00EPIP-01EPIP-02EPIP-03EPIP-04EPIP-05EPIP-06EPIP-07EPIP-08EPIP-09EPIP-10EPIP-11EPIP-12EPIP-13HP-90HP-200HP-201DiscoveryandIdentificationofanEmergencyCondition(includingChemical,FireandNaturalEmergencies)ClassificationofEmergenciesDutiesandResponsibilitiesoftheEmergencyCoordinatorEmergencyResponseOrganizationNotification/StaffAugmentationActivationandOperationoftheTechnicalSupportCenterActivationandOperationoftheOperationalSupportCenterActivationandOperationoftheEmergencyOperationsFacilityConductofEvacuations/AssemblyOff-siteNotificationsandProtectiveActionRecommendationsOffsiteDoseCalculationsOff-SiteRadiologicalMonitoringCoreDamageAssessmentMaintainingEmergencyPreparedness-RadiologicalEmergencyPlanTrainingMaintainingEmergencyPreparedness-EmergencyExercises,Drills,TestsandEvaluationsEmergencyEquipmentHPEmergencyOrganizationEmergencyPersonnelExposureControlRevisionNo.DateReviewedPCRY/N/R5
REVISIONNO.:PROCEDURENoEPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTDATASHEET3EPIPBIENNIALREVIEW(Page2of2)PAGE:18of35(YEAR)I.EmergencyPlanImplementingProcedures(Biennial)(continued)HP-202HP-203HP-204HP-205HP-206HP-207HP-208COP-06.06COP-06.11EnvironmentalMonitoringDuringEmergenciesPersonnelAccessControlDuringEmergenciesInPlantRadiationandContaminationSurveysduringEmergenciesEmergencylnplantAirSamplingAnalysisofEmergencyInplantAirSamplesMonitoringEvacuatedPersonnelDuringEmergenciesPersonnelDecontaminationDuringEmergenciesGuidelinesforCollectingPostAccidentSamplesEstablishingRemoteLaboratoryforAnalysisofAccidentSamplesRevisionNo.DateReviewedPCRY/NENDOFDATASHEET3 REVISIONNo.:PROCEDURENo.:EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTDATASHEET4EPEXERCISECHECKLISTPAGE:19of35ExerciseItems:(YEAR)INITIAL/DATE1.ExerciseDateSelection:A.EvaluatedDate~~2.EROParticipantNotification3.ScenarioDevelopmentPersonnelAssigned4.Controllers/EvaluatorsAssigned5.ExerciseObjectivesA.ProtectionServicesManagerApprovalB.SubmittedtoLicensing(75DayNRCSubmittal,Evenyearsonly)6.ExerciseScenarioA.ProvidedtoFloridaDEM(60DayFEMASubmittal,Evenyearsonly)B.SubmittedtoLicensing(45DayNRCSubmittal,Evenyearsonly)7.PostExerciseCritiqueDate:~~8.FacilityReviewGroup(FRG)CritiqueReportReviewENDOFDATASHEET4 REVISIONNo.:PROCEDURENo.:EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTATlACHMENT1EPPROGRAMSCHEDULEPAGE:20of35(Page1of16)JANUARY(YEAR)INITIAL/DATE1~EmergencyResponseFacilitySurveillance:DateTSCOSCEOF2.$,Off-HoursAugmentationMethodologies:A.Weeklytestofautomatedemergencyrecallsystem(Autodialer).Dates:/R5B.MonthlyreviewofEmergencyResponseDirectory.3.OtherSurveillances/Drills/Evolutions:A.B.D.F.
REVISIONNo.:PROCEDURENO.:EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTPAGE:21of35ATTACHMENT1EPPROGRAMSCHEDULE(Page2of16)FEBRUARY(YEAR)INITIAL/DATEEmergencyResponseFacilitySurveillance:DateTSCOSCEOF2.$,Off-HoursAugmentationMethodologies:A.Weeklytestofautomatedemergencyrecallsystem(Autodialer)~Dates:/R5B.MonthlyreviewofEmergencyResponseDirectory.3.OtherSurveillances/Drills/Evolutions:A.B.C.D.
REVISIONNo.:PROCEDURENoEPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTPAGE:22of35ATTACHMENT1EPPROGRAMSCHEDULE(Page3of16)MARCH1.EmergencyResponseFacilitySurveillance:Date(YEAR)INITIAL/DATETSCOSCEOF2.$,Off-HoursAugmentationMethodologies:A.Weeklytestofautomatedemergencyrecallsystem(Autodialer)~Dates:/R5B.MonthlyreviewofEmergencyResponseDirectory.C.QuarterlyverificationofEmergencyResponseDirectoryData.D.QuarterlyverificationofDistributionListforEmergencyResponseDirectory.E.QuarterlypublicationofEmergencyResponseDirectory.~3.QuarterlyIntegratedFacilityActivationDrillDrillDate4.QuarterlyOff-HoursCall-OutPhoneTestDrillDate5.QuarterlySelf-Assessment REVISIONNO.:PROCEDURENo.:EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTATTACHMENT1EPPROGRAMSCHEDULE(Page4of16)PAGE:23of35MARCH(continued)(YEAR)INITIAL/DATE6.QuarterlysubmittalofEPPerformanceIndicatorsA.ParticipationB.Drill&ExercisePerformanceC.Alert&NotificationSystem7.g,QuarterlytestoftheNRCEmergencyResponseDataSystem(ERDS)link.8.OtherSurveillances/Drills/Evolutions/R5 REVISIONNo.:5PROCEDURENo.EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTATTACHMENT1EPPROGRAMSCHEDULEPAGE:24of35(Page5of16)APRIL1.EmergencyResponseFacilitySurveillance:Date(YEAR)INITIAL/DATETSCOSCEOF2.$,Off-HoursAugmentationMethodologies:A.Weeklytestofautomatedemergencyrecallsystem(Autodialer).Dates:/R5B.MonthlyreviewofEmergencyResponseDirectory.3.OtherSurveillances/Drills/Evolutions:A.C.D.F.
REVISIONNo.:PROCEDURENoEPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTATTACHMENT1EPPROGRAMSCHEDULEPAGE:25of35(Page6of16)MAY1.EmergencyResponseFacilitySurveillance:Date(YEAR)INITIAL/DATETSCOSCEOF2.tt,Off-HoursAugmentationMethodologies:A.Weeklytestofautomatedemergencyrecallsystem(Autodialer).Dates:/R5B.MonthlyreviewofEmergencyResponseDirectory.3.OtherSurveillances/Drills/Evolutions:A.B.D.
REVISIONNo.:5PROCEDURENo.:EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTPAGE:26of35ATTACHMENT1EPPROGRAMSCHEDULE(Page7of16)JUNE(YEAR)INITIAL/DATE1~EmergencyResponseFacilitySurveillance:DateTSCOSCEOF2.$,Off-HoursAugmentationMethodologies:A.Weeklytestofautomatedemergencyrecallsystem(Autodialer).Dates:B.MonthlyreviewofEmergencyResponseDirectory.C.QuarterlyverificationofEmergencyResponseDirectoryData.J/R5D.QuarterlyverificationofDistributionListforEmergencyResponseDirectory.E.QuarterlypublicationofEmergencyResponseDirectory.~3.QuarterlyIntegratedFacilityActivationDrillDrillDate4.QuarterlyOff-HoursCall-OutPhoneTestDrillDate5.QuarterlySelf-Assessment REVISIONNo.:PROCEDURENO.:EPIP-l3PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTATTACHMENT1EPPROGRAMSCHEDULE(Page8of16)PAGE:27of35JUNE(continued)(YEAR)INITIAL/DATE6.QuarterlysubmittalofEPPerformanceIndicatorsA.ParticipationB.Drill8ExercisePerformanceC.Alert8NotificationSystem7.g,QuarterlytestoftheNRCEmergencyResponseDataSystem(ERDS)link.8.OtherSurveillances/Drills/Evolutions/R5 REVISIONNo.:PROCEDURENO.:EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTATTACHMENT1EPPROGRAMSCHEDULEPAGE:28of35(Page9of16)JULY1~EmergencyResponseFacilitySurveillance:Date(YEAR)INITIAL/DATETSCOSCEOF2.$,Off-HoursAugmentationMethodologies:A.Weeklytestofautomatedemergencyrecallsystem(Autodialer).Dates:/R5B.MonthlyreviewofEmergencyResponseDirectory.3.OtherSurveillances/Drills/Evolutions:A.B.D.
REVISIONNO.:PROCEDURENO.:EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTPAGE:29of35ATTACHMENT1EPPROGRAMSCHEDULE(Page10of16)AUGUST(YEAR)INITIAL/DATEEmergencyResponseFacilitySurveillance:DateTSCOSCEOF2.$,Off-HoursAugmentationMethodologies:A.Weeklytestofautomatedemergencyrecallsystem(Autodialer).Dates:B.MonthlyreviewofEmergencyResponseDirectory.3.OtherSurveillances/Drills/Evolutions:/R5A.D.F.
REVISIONNo.:5PROCEDURENO.:EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTATTACHMENT1EPPROGRAMSCHEDULEPAGE:30of35(Page11of16)SEPTEMBER(YEAR)INITIAL/DATE1.EmergencyResponseFacilitySurveillance:DateTSCOSCEOF2.$,Off-HoursAugmentationMethodologies:A.Weeklytestofautomatedemergencyrecallsystem(Autodialer).Dates:/R5B.MonthlyreviewofEmergencyResponseDirectory.C.QuarterlyverificationofEmergencyResponseDirectoryData.D.QuarterlyverificationofDistributionListforEmergencyResponseDirectory.1E.QuarterlypublicationofEmergencyResponseDirectory.~3.QuarterlyIntegratedFacilityActivationDrillDrillDate4.QuarterlyOff-HoursCall-OutPhoneTestDrillDate5.QuarterlySelf-Assessment REVISIONNO.:PROCEDURENO.:EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTPAGE:31of35ATTACHMENT1EPPROGRAMSCHEDULE(Page12of16)SEPTEMBER(continued)(YEAR)INITIAL/DATE6.QuarterlysubmittalofEPPerformanceIndicatorsA.ParticipationB.Drill&ExercisePerformanceC.Alert8NotificationSystem7.g,QuarterlytestoftheNRCEmergencyResponseDataSystem(ERDS)link.8.OtherSurveillances/Drills/Evolutions/R5 REVISIONNo.:PROCEDURENo.EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTPAGE:32of35ATTACHMENT1EPPROGRAMSCHEDULE(Page13of16)OCTOBER1.EmergencyResponseFacilitySurveillance:Date(YEAR)INITIAL/DATETSCOSCEOF2.$,Off-HoursAugmentationMethodologies:A.Weeklytestofautomatedemergencyrecallsystem(Autodialer).Dates:/R5B.MonthlyreviewofEmergencyResponseDirectory.3.OtherSurveillances/Drills/Evolutions:A.C.D.F.
REVISIONNO.:PROCEDURENO.:EPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTPAGE:33of35ATTACHMENT1EPPROGRAMSCHEDULE(Page14of16)NOVEMBER(YEAR)INITIAL/DATE1.EmergencyResponseFacilitySurveillance:DateTSCOSCEOF2.$,Off-HoursAugmentationMethodologies:A.Weeklytestofautomatedemergencyrecallsystem(Autodialer)~Dates:/R5B.MonthlyreviewofEmergencyResponseDirectory.3.OtherSurveillances/Drills/Evolutions:A.C.D.F.
REVISIONNO.:5PROCEDURENO.EPIP-I3PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANTPAGE:34of35ATTACHMENT1EPPROGRAMSCHEDULE(Page15of16)DECEMBER(YEAR)INITIAL/DATE1.EmergencyResponseFacilitySurveillance:DateTSCOSCEOF2.$,Off-HoursAugmentationMethodologies:A.Weeklytestofautomatedemergencyrecallsystem(Autodialer).Dates:/R5B.MonthlyreviewofEmergencyResponse=Directory.C.QuarterlyverificationofEmergencyResponseDirectoryData.D.QuarterlyverificationofDistributionListforEmergencyResponseDirectory.E.QuarterlypublicationoiEmergencyResponseDirectory.~3.QuarterlyIntegratedFacilityActivationDrillDrillDate4.QuarterlyOff-HoursCall-OutPhoneTestDrillDate5.QuarterlySelf-Assessment REVISIONNo.:PROCEDURENoEPIP-13PROCEDURETITLE:MAINTAININGEMERGENCYPREPAREDNESS-EMERGENCYEXERCISES,DRILLS,TESTSANDEVALUATIONSST.LUCIEPLANT....,ATTACHMENT1EPPROGRAMSCHEDULEPAGE:35of35(Page16of16)DECEMBER(continued)6.QuarterlysubmittalofEPPerformanceIndicatorsA.ParticipationB.Drill8ExercisePerformanceC.Alert8NotificationSystem7.g,QuarterlytestoftheNRCEmergencyResponseDataSystem(ERDS)link.8.OtherSurveillances/Drills/Evolutions(YEAR)INITIAL/DATE/R5ENDOFATTACHMENT1 l~5<9yg<m~<~M&~gW~+Pi5~$7/leak'('~~/I+8'4~4Title:FPLST.LUCIEPLANTEMERGENCYPLANIMPLEMENTINGPROCEDURESAFETYRELATEDProcedureNo.EPIP-02CurrentRev.o.8Effect'Date:'t20/00DUTIESANDRESPONSIBILITIES,'HEEMERGENCYCOORDINATO/RResponsibleDepament:RevisionSummaryEMERGENCYPLANNINGRevision8-Revisedoff-iteassemblyareatojensenpublicbeacparkingareainaccordancewithrevision3oftheE-Planandmadeadministrativechanged.(J.R.Walker,10/13/00)Revision7-DeletedpolicyreferenceperPMAI,clarifiedvylndspeedforunitshutdown,revisedre-entryguidelinesandmdeeditorialchanges.(J.R.Walker,09/21/00)Revision6-THISPROCEDUREHBEENCOMETELYREWRITTEN.Deletedinformationandinstructionsforoff-siteotificationandPARs.RelocatedtonewEPIP-08off-sitenotificationsandprotectiveactionecomendations.AddressedearlyactivationofemergencyresponsefacilitiesperPMAIP003-122.Madeadministrativeandeditorialchanges.(DonnaCalabrese,05/31/00)Revision5-Addedinstructionsforimpleentati/actuationofnewgai-tronicsalarm-emergencyplanactivationandmadehmanfactorimprovements.(J.R.Walker,01/18/00)PSLPROCCDUEP"OBDUCTIONRevisionFRGReviewDate12/15/97RevisionyFRGReviewDate3+10/13/00ApprovedByJ.ScaroiaPlantGeneralManagerApprovedByR.G.WestPlantGeneralManagerN/ADesignatedApproverApprovalDate12/15/97ApprovalDate10/13/00SOPSDATEDOCTPROCEDUREDOCNEPIP-02SYSCOMPCOMPLETEDITM8
REVISIONNO.:PROCEDURENo.:EPIP-02PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORST.LUCIEPLANTTABLEOFCONTENTSPAGE:2of34SECTIONPAGE1.0PURPOSE.~...~~....~................~............~..
32.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTS.33.0RESPONSIBILITIES3.1NuclearPlantSupervisor3.2EmergencyCoordinator........~~~..5~~~~~554.0DEFINITIONS..~.........~..~~~~~~~~~~~~~~~~~~~~~~~65.0INSTRUCTIONS....~..~......~.~......5.1GeneralOverview5.2EmergencyDeclarationChecklist5.3UnusualEventChecklist~~.~.........5.4AlertChecklist.~..~..~..~~.~.~....5.5SiteAreaorGeneralEmergencyChecklist7~~~~7121316~...20ATTACHMENTSATTACHMENT1InitialNotificationFlow..ATTACHMENT2CriteriaforEvacuation..~~~~~~~~~~~~~2728ATTACHMENT3TurnoverGuidelines.......~~....~~..~....~29ATTACHMENT4Re-entryGuidelines....~..~~~.....~...~......31ATTACHMENT5BasisforExposureLimitsforEmergencyResponsePersonnel.~...~............~..~.......~...32 REVISIONNO.:PROCEDURENo.:EPIP-021.0PURPOSEPROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORST.LUCIEPLANTPAGE:3of34ThisprocedureprovidesguidanceandinstructionstobefollowedbytheEmergencyCoordinatorwhenanemergencyoccursthatrequirestheimplementationoftheRadiologicalEmergencyPlanforSt.LuciePlant.NOTEOneormoreofthefollowingsymbolsmaybeusedinthisprocedure:gIndicatesaRegulatorycommitmentmadebyTechnicalSpecifications,ConditionofLicense,Audit,LER,Bulletin,etc.,andshallNOTberevisedwithoutFacilityReviewGroupreviewandPlantGeneralManagerapproval~Indicatesamanagementdirective,vendorrecommendation,plantpracticeorothernon-regulatorycommitmentthatshouldNOTberevisedwithoutconsultationwiththeplantstaff.
2.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTS2.1References1~St.LuciePlantUpdatedFinalSafetyAnalysisReport(UFSAR)Unit1andUnit2(Section9.5.A.7.2)2.St.LuciePlantRadiologicalEmergencyPlan(E-Plan)3.St.LuciePlantPhysicalSecurityPlan4.St.LuciePlantSafeguardsContingencyPlan5.E-PlanImplementingProcedures(EPIP00-13)6.10CFR50,DomesticLicensingofProductionandUtilizationFacilities.7.NUREG/BR-0150,Vol.1,ResponseTechnicalManual(USNRC).8.NUREG-0654,FEMA-REP-1,Rev.1,CriteriaforPreparationandEvaluationofRadiologicalEmergencyResponsePlansandPreparednessinSupportofNuclearPowerPlants.
REVISIONNo.:8PROCEDURENO.:EPIP-02PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORST.LUCIEPLANTPAGE:4of3
42.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTS(continued)2.1(continued)9.EPA400-R-92-001,ManualofProtectiveActionsGuidesandProtectiveActionsforNuclearIncidents,October,1991~2.2RecordsRequiredflioAcopyofthechecklistsordatageneratedbythisprocedureshallbemaintainedintheplantfilesinaccordancewithQI-17-PSL-1,QualityAssuranceRecords.Recordsinclude:EmergencyClassChecklists2.3CommitmentDocuments1.PMAIPM96-04-165,"ITR96-006"(UnusualEventDeclaredDuetoDroppedRod)2.NRCInspectionReport91-01,ClosureofIFls89-31-03and89-31-01Iio3.PMAIPM96-09-185,ConditionReportCR-96-1750(Off-siteNotificationUsingCommercialPhone)4.PMAIPM96-05-233,(Off-siteNotificationProcess).5.ConditionReportCR96-2389,(Off-siteDoseCalculations).6.ConditionReportCR98-1536(ECResponsibilitiesRemainintheControlRoom)~7.PMAIPM98-09-006(ControlofNLOsUnderE-Plan).8.ConditionReportCR99-1406(FieldOperatorDosimetryUnderE-Plan).9.PMAIPM99-10-191,ConditionReportCR99-1656(QualityRecords,DownpowerGuidanceDuetoHurricanes).
REVISIONNo.:8PROCEDURENOEPIP-02PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORST.LUCIEPLANTPAGE:5of3
42.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTS(continued)2.3(continued)10.PMAIPM99-10-142,ConditionReportCR99-1647(ECTurnover).11~PMAIPM99-09-016,(PARsBasedonFMTData,CompletionofNRCNotificationForm).ll>412.PMAIPM00-01-043,(Gai-TronicsE-PlanAlarm).13.PMAIPM00-03-122,(EarlyActivationofERFs).3.0RESPONSIBILITIES3.1TheNuclearPlantSupervisor(NPS)andtheshiftoperatingstaffrepresentthefirstlineofresponsetoanydevelopingemergencycondition.TheprimaryresponsibilityoftheNPSistocontroltheconditionaswellaspossible.3.2TheNPSupondeclarationofanemergencyclassificationbecomestheEmergencyCoordinator(EC)~TheNPSremainstheECuntilthepositionisturnedover.SpecificResponsibilitiesoftheECare:Directionoftheon-siteemergencyorganizationtobringtheemergencyundercontrol.Notificationofoff-siteagencieswithinspecifictimelimitsasmandatedbyregulations.ChangesinEmergencyClassificationbasedonchangingconditions.ProtectiveActionRecommendations(PARs)untilturnovertotheRecoveryManager.InterfaceswiththeNuclearRegulatoryCommission(NRC)ReactorSafetyOperationsCoordinator(RSOC)whentheNRCsiteteamarrivesattheTSC.
REVISIONNo.:PROCEDURENO.:EPIP-02PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORST.LUCIEPLANTPAGE:6of344.0DEFINITIONS4.1OwnerControlledAreaEvacuation(=SiteEvacuation)-Theevacuationfromtheownercontrolledareaofailpersonnelexceptthoserequiredtoplacetheplantinasafecondition,theEmergencyResponseOrganization(ERO),andSecuritypersonneltofulfillresponsibilitiesforevacuation.4.2Release(duringanydeclaredemergency)1~Anyeffluentmonitorincreaseof(approximately)10timesoronedecadeabovepre-transientvalues.OR2.HealthPhysicsdetectingairborneradioactivitylevelsinexcessof25%derivedairconcentration(DAC)outsideofplantbuildingsduetofailureofequipmentassociatedwiththedeclaredemergency.
REVISIONNO.:PROCEDURENO.:PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORPAGE:7of34EPIP-025.0INSTRUCTIONSST.LUCIEPLANT5.1GeneralOverviewtt7,11UponDeclarationofanemergencyclassificationtheNPSbecomestheEC.ToensureaccesstotheECfordirectionandcontroldecisionsandsothattheresponsibilitiesofthepositioncanbesuccessfullycompleted,theECpositionshallremain,initiallyintheaffectedControlRoomandthenintheTechnicalSupportCenter(TSC),whenitgoesoperational.PriortotheTSCbeingoperational,thedutiesandresponsibilitiesoftheEC,whileaControlRoomposition,maybeturnedovertoanotherqualifiedEC:~IfbothUnitsareinclassifiedevents,theECshouldlocateintheUnit'sControlRoomwiththehighestclassifiedevent.IfthesiteisinadualUnitevent,theECshouldlocateintheUnit1ControlRoom(duetoproximitytotheTSC).IftheTSCisactivated,ThentheECpositionisturnedovertoanECqualifiedmemberofplantmanagementandthepositionrelocatedtotheTSC.TheprospectiveECreceivesaturnover(refertoAttachment3,TurnoverGuidelines)fromtheControlRoomECandthenreportstotheTSC.FollowingverificationofTSCoperationalreadiness,theprospectiveECacceptsECresponsibilityfromtheControlRoomEC.TheTSCECmaytemporarilyturnoverresponsibilitytotheTSCOPSCoordinatorastheneedarises.2.Tomeettheaboveresponsibilities,plusothersdescribedinthisprocedure,theECwilllikelyneedtodelegatemanytasks.Althoughdelegated,thecompletionofthesetasksisstilltheresponsibilityoftheEC.
REVISIONNo.:PROCEDURENoPROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORPAGE:8of34EPIP-025.0INSTRUCTIONS(continued)ST.LUCIEPLANT5.1GeneralOverview(continued)2.(continued)TheECshallnotdeleatethefollowingresponsibilitiespriortoEmergencyOperationsFacility(EOF)beingdeclaredoperational:A.Classificationoftheemergency.B.Thedecisiontonotifystateandlocalauthoritiesandthecontentofthosenotifications.C.Recommendationofprotectiveactionsforthepublic.OncetheEOFisoperationalandproperturnoverhasbeenconducted,theRecoveryManager(RM)willassumeresponsibilityforoff-sitenotificationstothestateandlocalauthoritiesandforrecommendingprotectiveactions.3.OrderofSuccessionIftheNPSisincapacitated,ThentheECshallbe(inorderofsuccession):A.AssistantNuclearPlantSupervisor(ANPS)(fromtheaffectedunit)B.NuclearWatchEngineer(NWE)C.AnyothermemberoftheplantstaffwithanactiveSROlicense.4.WatchReliefA.TheECshallgrantpermissionforwatchrelief,includinghis/herown,onlywhenitissafeinhis/herjudgementtodoso.
REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORPAGE:9of34EPIP-025.0INSTRUCTIONS(continued)ST.LUCIEPLANT5.1GeneralOverview(continued)II45.EarlyActivationofEmergencyResponseFacilitiesItmaybeusefultohavetechnicaland/oroperationalsupportavailableearlyinanemergencypriortowhentheTechnicalSupportCenter(TSC),OperationalSupportCenter(OSC),orEmergencyOperationsFacility(EOF)isrequiredtobeoperational~Activationofanyofthesefacilitiesdoesnotrequiredeclarationofanemergencyclassorentryintoaspecificemergencyclassification.Ifearlyactivationofoneormoreofthefacilitiesisdesired,thenfollowtheseguidelines:A.Thisisanoptionduringnormalworkinghoursonly.B.ApageannouncementshouldbemadetorequestthatappropriateEmergencyResponseOrganizationpersonneltoreporttothefidentifywhatfacility/facilitiesis/aretobeactivatedearly].C.TurnoverofECresponsibilitiesisdoneinaccordancewithStep5.1.1.,above.D.TheE-PlanActivationAlarmisusedonlywhentheEmergencyResponseFacilities(ERFs)aretobeactivatedinaccordancewiththerequirementsoftheEmergencyPlan(i.e.,attheAlertorhigheremergencylevel)andisprovidedforinthechecklistincludedinthisprocedure.E.StaffaugmentationduetoactualfacilityactivationistobedoneinaccordancewiththeAlertChecklistorSiteAreaorGeneralEmergencyChecklistwhicharepartofthisprocedure.6.SecurityEventA.SitesecurityandLocalLawEnforcement(LLEA)willtaketheleadinresponsetoaSecurityEventinaccordancewiththeSecurityPlan.
REVISIONNO.:PROCEDURENo.:PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORPAGE:10of34EPIP-025.0INSTRUCTIONS(continued)ST.LUCIEPLANT5.1GeneralOverview(continued)6.(continued)B.BasedonthenatureoftheSecurityEventandasconditionswarrant,theEmergencyCoordinatormaydelay,postponeorinstitutespecialarrangementsconcerning,butnotlimitedto:EmergencyResponseFacility(ERF)activationLocalorSiteEvacuationSiteorRadiationControlledArea(RCA)accessOperatorfieldactivitiesUnitshutdown7.SevereWeatherConsiderationsIfahurricanewarningisineffect,andeitheroneorbothUnit(s)is/areinMode1,2or3,Thenusethefollowingcriteriaforunitshutdown:NOTESustainedhurricaneforcewindsaresustainedwindsof74mph(64ktor119kph)orgreater.A.ForstormsprojectedtoreachaCategory1or2,theUnit(s)shallbeplacedinHOTSTANDBY(Mode3)orbelowatleasttwo(2)hoursbeforetheprojectedonsetofsustainedhurricaneforcewindswithintheOwnerControlledAreaandbothUnitsshallremainoff-lineforthedurationofthehurricaneforcewinds(orrestorationofreliableoffsitepower).B.ForstormsprojectedtoreachCategory3,4and5priortolandfall,theUnitsshallbeshutdowntoatemperaturelessthan350degreesTave.atleasttwo(2)hoursbeforetheprojectedonsetofsustainedhurricaneforcewindswithintheOwnerControlledAreaandbothUnitsshallremainoff-lineforthedurationofthehurricaneforcewinds(orrestorationofreliableoffsitepower).C.Establishanacceptableupdatefrequencywithstateandlocalofficials.
REVISIONNo.:PROCEDURENo.:EPIP-02PROCEDURETITLE:.DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORST.LUCIEPLANTPAGE:11of345.0INSTRUCTIONS(continued)5.1GeneralOverview(continued)8.DrillMessagesDuringexercises,drills,ortests,ALLMESSAGESshallbeginandendwithTHISISADRILLorTHISISANEXERCISEorTHISISATEST.ENDOFSECTION5.1 REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORPAGE:12of34EPIP-025.0INSTRUCTIONS(continued)ST.LUCIEPLANTTIME/INIT5.2EmergencyDeclarationChecklistCAUTIONStateand/orlocalauthoritiesshallbenotifiedwithin15minutesofdeclarationoftheemergencyclassification.NOTEStepsshouldbeperformedintheorderpresented.Whenconditionswarrant,stepsmaybeperformedoutofsequence.PAannouncementsareprovidedasaguideline.Actualannouncementsmayvaryfromthetextprovided.TheNPSshalldeclaretheemergencytotheControlRoomstaffandformallyannouncethathe/sheistheEmergencyCoordinator(EC).2.NotifyplantpersonnelusingGai-tronicsandboostfunction."Attentionallplantpersonnel,Unit~1~2hasdeclared~i.BtiftTtilAdidOtyGIISupervisorreporttotheControlRoomimmediately.Allotherplantpersonnelbeawareandlistenforfurtherinstructions.Limitradioandphoneuseuntilfurthernotice."3.CompletetheappropriateEmergencyClassificationSectionChecklist(attached):A.Section5.3(Notificationof)UnusualEventChecklistB.Section5.4AlertChecklistC.Section5.5SiteAreaorGeneralEmergencyChecklistENDOFSECTION5.2 REVISIONNO.:PROCEDURENo.:PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORPAGE:13of34EPIP-025.0INSTRUCTIONS(continued)ST.LUCIEPLANTTIME/INIT5.3UNUSUALEVENTCHECKLISTDate~~Message¹NOTE~PrepareanewchecklistforeachnotificationmadeduringanUnusualEventemergency.~Theterm"release"hasaspecificdefinitioninSection4.0ofthisprocedure.CAUTIONAnydatarelatedtoareleaseofradioactivematerial(e.g.,off-sitedoseprojectionsorfieldmonitoringreadings)shallfirstbereviewedagainsttheEmergencyActionLevels(EALs)inEPIP-01,ClassificationofEmergencies,andsecondarilyagainsttheProtectiveActionRecommendation(PAR)guidanceinEPIP-08,Off-SiteNotificationsandProtectiveActionRecommendations,forapplicability.1.Ifaradioactivereleasehasoccurredorisinprogress,ThennotifyChemistrytopromptlyperformoff-sitedosecalculationsperEPIP-09,Off-siteDoseCalculations,andreportresultstotheEC.IfChemistryisunavailable,ThenhavetheDCScalloutaChemist.2.Ifevacuationofanareaisnecessary,TheninitiatealocalevacuationinaccordancewithEPIP-07,ConductofEvacuations/Assembly.(RefertoAttachment2,CriteriaforEvacuation.)3.MobilizeemergencyresponsepersonneltorespondasrequiredusingGai-tronicsandboostfunction.
REVISIONNo.:PROCEDURENO.:PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORPAGE:14of34EPIP-025.0INSTRUCTIONS(continued)ST.LUCIEPLANTTIME/INIT5.3UNUSUALEVENTCHECKLIST(continued)NOTETheDutyCallSupervisor(DCS)isaspecificallydesignatedandtrainedsupervisorresponsibleforassistingtheEmergencyCoordinator(EC)inmakingnotificationsandcallstotheEmergencyResponseOrganization(ERO).4.IftheDCSisnotavailabletoperformoff-sitenotifications,ThenperformtherequirednotificationsinaccordancewithEPIP-08,Off-siteNotificationsandProtectiveActionRecommendations.5.EnsurenotificationofPlantManagement,SecurityandtheNuclearDivisionDutyOfficer(NDDO).ThismaybeaccomplishedbytheDCS.6.Reassesscorrectiveandprotectiveactions.Verifyassignedactivitiesareunderwayandproperprogressisbeingmade.Reassignpersonnelandemergencyteamsasnecessary./RB7.ContinuetoassessconditionsandreviewanychangesagainsttheEmergencyActionLevels(EALs)inEPIP-01,ClassificationofEmergencies./R88.Reclassifytheeventasnecessaryandfollowinstructionsintheappropriatechecklist./R8NOTENewnotificationformsshallbepreparedforallupdates.9.Iftheclassificationisunchangedbutasignificantchangeinplantconditionshasoccurred,ThenstartanewUnusualEventChecklist.
REVISIONNO.:PROCEDURENo.:EPIP-02PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORST.LUCIEPLANTPAGE:15of345.0INSTRUCTIONS(continued)5.3UNUSUALEVENTCHECKLIST(continued)10.Iftheeventcanbeterminated,Thencompletethenotificationforms(State,NRC)andnotifythefollowing:StateWarningPointPlantManagementSecurityNDDOTIME/INITNRC11.AllUnusualEventChecklistitemscompleted/satisfied.ENDOFSECTION5.3 REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORPAGE:16of34EPIP-025.0INSTRUCTIONS(continued)5.4ALERTCHECKLISTST.LUCIEPLANTTIME/INITDate~~Message¹NOTE~ForassistancewithcontrolofNon-licensedOperators(NLOs),referto:~Attachment4,Re-entryGuidelines.~Attachment5,BasisforExposureLimitsforEmergencyResponsePersonnel.~PrepareanewchecklistforeachnotificationmadeduringanAlertemergency.~Theterm"release"hasaspecificdefinitioninSection4.0ofthisprocedure.CAUTIONAnydatarelatedtoareleaseofradioactivematerial(e.g.,off-sitedoseprojectionsorfieldmonitoringreadings)shallfirstbereviewedagainsttheEmergencyActionLevels(EALs)inEPIP-01,ClassificationofEmergencies,andsecondarilyagainsttheProtectiveActionRecommendation(PAR)guidanceinEPIP-08,Off-SiteNotificationsandProtectiveActionRecommendations,forapplicability.1~Ifaradioactivereleasehasoccurredorisinprogress,ThennotifyChemistrytopromptlyperformoff-sitedosecalculationsperEPIP-09,Off-siteDoseCalculations,andreportresultstotheEC.IfChemistryisunavailable,ThenhavetheDCScalloutaChemist.2.Ifevacuationofanareaisnecessary,TheninitiatealocalevacuationinaccordancewithEPIP-07,-ConductofEvacuations/Assembly.(RefertoAttachment2,CriteriaforEvacuation.)
REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORPAGE:17of34EPIP-025.0INSTRUCTIONS(continued)ST.LUCIEPLANTTIME/INIT5.4ALERTCHECKLIST(continued)3.SoundtheEmergencyPlan(E-Plan)ActivationAlarm(N/Aforupdates).4.NotifyplantpersonneloftheemergencydeclarationusingGai-tronicsandboostfunction(N/Aforupdates)~"Attentionallplantpersonnel,Unit~1/~2hasdeclaredanALERT.""Allemergencyresponseorganizationpersonnelreportatoncetoyourassignedemergencyresponsefacility.""Allnon-emergencyresponseorganizationpersonnelreporttoyournormalworklocationorcontactyoursupervisor."Repeattheannouncement.5.Ifareleaseisinprogress,ThenreviewpersonnelaccesswithHealthPhysicspersonnelandnotifySecuritypersonnelwithanyspecialinstructions(N/Aforupdates)~NOTETheDutyCallSupervisor(DCS)isaspecificallydesignatedandtrainedSupervisorresponsibleforassistingtheEmergencyCoordinator(EC)inmakingnotificationsandcallstotheEmergencyResponseOrganization(ERO)~6.IftheDCSisnotavailabletoinitiatestaffaugmentation,Thenperformthecall-outprocessinaccordancewithEPIP-03,"EmergencyResponseOrganizationNotification/StaffAugmentation."(N/Aforupdates.)
REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORPAGE:18of34EPIP-025.0INSTRUCTIONS(continued)ST.LUCIEPLANTTIME/INIT5.4ALERTCHECKLIST(continued)7.IftheDCSisnotavailabletoperformoff-sitenotifications,ThenperformtherequirednotificationsinaccordancewithEPIP-08,Off-siteNotificationsandProtectiveActionRecommendations.8.VerifynotificationofPlantManagement,SecurityandtheNDDO.ThismaybeaccomplishedbytheDCS.9.InitiatetheOperationsDepartmentAccountabilityAidforbothUnit1andUnit2andprovidethislisttotheTSCwhenrequested.ThismaybeaccomplishedbytheDCS.(N/Aforupdates).10.EnsureOperationsfieldpersonnelhavereturnedtotheControlRoomtoobtainemergencyElectronicPersonalDosimetry(EPD)fromtheHPKit.11.Reassesscorrectiveandprotectiveactions.Verifyassignedactivitiesareunderwayandproperprogressisbeingmade.Reassignpersonnelandemergencyteamsasnecessary./R812.ContinuetoassessconditionsandreviewanychangesagainsttheEmergencyActionLevels(EALs)inEPIP-01,ClassificationofEmergencies./R813.Reclassifytheeventasnecessaryandfollowinstructionsintheappropriatechecklist./RBNOTENewnotificationformsshallbepreparedforallupdates.14.Iftheclassificationisunchangedbutasignificantchangeinplantconditionshasoccurred,ThenstartanewAlertChecklist.
REVISIONNo.:PROCEDURENoEPIP-02PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORST.LUCIEPLANTPAGE:19of345.0INSTRUCTIONS(continued)5.4ALERTCHECKLIST(continued)15.IfaState/Localnotificationhasnotbeencompletedinthelast60minutes,Thenprovidearoutineupdate.Startanewnotificationformandmaketheappropriatenotifications.16.Iftheeventcanbeterminated,Thencompletethenotificationforms(State,NRC)andnotifythefollowing:StateWarningPointPlantManagementSecurityNDDOTIME/INITNRC17.AllAlertChecklistitemscompleted/satisfied.ENDOFSECTION5.4 REVISIONNO.:PROCEDURENo.:PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORPAGE:20of34EPIP-025.0INSTRUCTIONS(continued)ST.LUCIEPLANTTIME/INIT5.5SITEAREAORGENERALEMERGENCYCHECKLISTDate~~Message0NOTE~ForassistancewithcontrolofNon-licensedOperators(NLOs),referto:~Attachment4,Re-entryGuidelines~Attachment5,BasisforExposureLimitsforEmergencyResponsePersonnel~PrepareanewnotificationformforeachnotificationmadeduringaSiteAreaEmergencyorGeneralEmergency.~Theterm"release"hasaspecificdefinitioninSection4.0ofthisprocedure.CAUTIONAnydatarelatedtoareleaseofradioactivematerial(e.g.,off-sitedoseprojectionsorfieldmonitoringreadings)shallfirstbereviewedagainsttheEmergencyActionLevels(EALs)inEPIP-01,ClassificationofEmergencies,andsecondarilyagainsttheProtectiveActionRecommendation(PAR)guidanceinEPIP-08,Off-SiteNotificationsandProtectiveActionRecommendations,forapplicability.Ifaradioactivereleasehasoccurredorisinprogress,ThennotifyChemistrytopromptlyperformoff-sitedosecalculationsperEPIP-09,Off-siteDoseCalculations,andreportresultstotheEmergencyCoordinator.IfChemistryisunavailable,ThenhavetheDCScalloutaChemist.2.Ifaradioactivereleasehasoccurredorisinprogress,Thenidentifywinddirection.
REVISIONNO.:PROCEDURENo.:EPIP-02PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORST.LUCIEPLANTPAGE:21of345.0INSTRUCTIONS(continued)TIME/INIT5.5SITEAREAORGENERALEMERGENCYCHECKLIST(continued)NOTEWhentheEOFisdeclaredoperationalANDtheRecoveryManagerhasassumedresponsibility,ThennotificationsandPARswillbeperformedfromtheEOF.3.Ifareleaseisinprogress,ThenreviewpersonnelaccesswithHealthPhysicspersonnelandnotifySecuritypersonnelwithanyspecialinstructions(N/Aforupdates)~4.IftheTechnicalSupportCenter,OperationalSupportCenterandEmergencyOperationsFacilityareNOTactivated,Then:A.SoundtheEmergencyPlan(E-Plan)ActivationAlarm(N/Aforupdates).B.NotifyplantpersonneloftheemergencydeclarationusingGai-tronicsandboostfunction(N/Aforupdates)."Attentionallplantpersonnel,Unit~1/~2hasdeclaredaSITEAREAEMERGENCY/GENERAL~EMERGENCY.""Allemergencyresponseorganizationpersonnelreportatoncetoyourassignedemergencyresponsefacility."C.RepeatStepsAandBabove(N/Aforupdates).5.IfthesiteisNOTevacuated,ThensoundtheSiteEvacuationAlarm.
REVISIONNo.:PROCEDURENoPROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORPAGE:22of34EPIP-025.0INSTRUCTIONS(continued)ST.LUCIEPLANTTIME/INIT5.5SITEAREAORGENERALEMERGENCYCHECKLIST(continued)NOTEToprovideaclearannouncement,thefollowingstepshouldbereadandthecontentoftheannouncementdeterminedpriortostartingtheannouncement.6.MakethenecessaryplantannouncementusingGai-tronicsandboostfunction:A.IfdoneinStep5.5.4above,ThenGOTOStep5.5.6.B.ORAnnouncethefollowing(N/Aforupdates):"Attentionallplantpersonnel,~Unit1/2hasdeclaredaSITEAREAEMERGENCY/GENERALEMERGENCY."NOTEAnalternateoff-siteAssemblyAreaattheJensenPublicBeachParkingAreaisavailableifthewinddirectionisfrom146to270'./R8B.IfthesiteisNOTevacuatedandthereisNOTorhasNOTbeenaradiologicalrelease,Thenannouncethefollowing:"Allnon-emergencyresponseorganization.personnelaretocommenceevacuationoftheOwnerControlledArea,reporttoyourvehicleandproceedtoyourhomes."ORIfthesiteisNOTevacuatedandthereisorhasbeenradiologicalrelease,Thenannouncethefollowing:
REVISIONNo.:PROCEDURENo.:EPIP-02PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORST.LUCIEPLANTPAGE:23of345.0INSTRUCTIONS(continued)TIME/INIT5.5SITEAREAORGENERALEMERGENCYCHECKLIST(continued)6.(continued)B.(continued)"Allnon-emergencyresponseorganizationpersonnelaretocommenceevacuationoftheOwnerControlledArea.Personsleavingthesitearetoproceed~NNI/S1ytttp~lJaceePark/JensenPublicBeachPkiAA1Iiihkaccountabilityandfurtherinstructions."7.IfaSITEAREAEMERGENCY,ThenREPEATSteps5.5.6.Aand5.5.6.Babove(N/Aforupdates).OR/R8IfaGENERALEMERGENCY,ThenREPEATStep5.5.6.Aabove(N/Aforupdates).8.IfthesiteisNOTevacuated,ThenorderSecuritytoensureevacuationoftheOwnerControlledAreaandtoreportpersonnelaccountabilityassoonaspossible(N/Aforupdates).
REVISIONNo.:PROCEDURENo.:EPIP-02PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORST.LUCIEPLANTPAGE:24of345.0INSTRUCTIONS(continued)TIME/INIT5.5SITEAREAORGENERALEMERGENCYCHECKLIST(continued)CAUTIONPARsarealwaysrequiredforGeneralEmergenciesandmayberequiredforlesseremergencies.RefertoEPIP-08,Off-siteNotificationsandProtectiveActionRecommendations.NOTETheDutyCallSupervisor(DCS)isaspecificallydesignatedandtrainedsupervisorresponsibleforassistingtheEmergencyCoordinator(EC)inmakingnotificationsandcallstotheEmergencyResponseOrganization(ERO)~9.IftheTSCandOSCareNOTactivated,Then:A.NotifytheDCStoinitiatestaffaugmentationinaccordancewithEPIP-03,EmergencyResponseOrganizationNotification/StaffAugmentation,ifavailable.ORB.Performthecall-outprocessinaccordancewithEPIP-03.10.IftheDCSisNOTavailabletoperformoff-sitenotifications,ThenperformtherequirednotificationsinaccordancewithEPIP-08,Off-siteNotificationsandProtectiveActionRecommendations.11.VerifynotificationofPlantManagement,SecurityandNDDO.ThismaybeaccomplishedbytheDCS.12.InitiatetheOperationsDepartmentAccountabilityAidforbothUnit1andUnit2andprovidethislisttotheTSCwhenrequested.ThismaybeaccomplishedbytheDCS.(N/Aforupdates)~
REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORPAGE:25of34EPIP-025.0INSTRUCTIONS(continued)ST.LUCIEPLANTTIME/INIT5.5SITEAREAORGENERALEMERGENCYCHECKLIST(continued)13.VerifywithSecuritythattheevacuationoftheOwnerControlledAreahasbeencompletedandallpersonnelhavebeenaccountedfor(N/Aforupdates).14.UpdatetheStateWarningPointandNRCwhentheevacuationiscomplete.ThismaybeaccomplishedbytheDCSorTSC.(N/Aforupdates).15.EnsureOperationsfieldpersonnelhavereturnedtotheControlRoomorOSCtoobtainemergencyElectronicPersonalDosimetry(EPD)(N/Afor-updates).16.DirectthatallNon-licensedOperators(NLOs),frombothUnits,reporttotheOSC(whenoperational)followingevacuationoftheOwnerControlledArea(N/Aforupdates).17.Reassesscorrectiveandprotectiveactions.Verifyassignedactivitiesareunderwayandproperprogressisbeingmade.Reassignpersonnelandemergencyteamsasnecessary.18.ContinuetoassessconditionsandreviewanychangesagainsttheEmergencyActionLevels(EALs)inEPIP-01,ClassificationofEmergencies.19.UpgradetoaGeneralEmergency,asnecessary.Startnewchecklistuponupgrading.20.IftheclassificationisunchangedbutasignificantchangeinplantconditionshasoccurredANDtheEOFisNOToperational,ThenstartanewSiteAreaorGeneralEmergencyChecklist,preparenotificationformsandmaketheappropriatenotificationsassoonaspossible.
REVISIONNo.:PROCEDURENO.:EPIP-02PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORST.LUCIEPLANTPAGE:26of345.0INSTRUCTIONS(continued)TIME/INIT5.5SITEAREAORGENERALEMERGENCYCHECKLIST(continued)CAUTIONOnlytheRecoveryManager(RM)canauthorizethedowngradingofemergencyclassificationsfromSiteAreaorGeneralEmergency.NOTEIftheEOFisnotoperationalatthistime,contactRecoveryManagerforinformationconcerningturnoverofnotificationandPARresponsibilities.21.Iftheeventcanbedowngradedorterminated,ThendiscusswithRecoveryManager.NOTENewnotificationformsshallbepreparedforallupdates.22.Ifanoff-sitenotificationhasnotbeencompletedinthelast60minutesANDtheEOFisNOToperational,Thenprovidearoutineupdate.Startanewnotificationformandmaketheappropriatenotifications.23.AllSiteAreaorGeneralEmergencyChecklistitemscompleted/satisfied.ENDOFSECTION5.5 REVISIONNO.:PROCEDURENO.:EPIP-02PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORST.LUCIEPLANTATTACHMENT1INITIALNOTIFICATIONFLOW(Page1of1)PAGE:27of34EMERGENCYCOORDINATORSTATEOFFLORIDADIVISIONOFEMERGENCYMANAGEMENTDUTYCALLSUPERVISORPLANTGENERALMANAGERSTATEOFFLORIDADOHBUREAUOFRADIATIONCONTROL(1)(5)FPLEMERGENCYRESPONSEORGANIZATIONEPZCOUNTIESEMERGENCYRESPONSEDIRECTORSUSNRCOPERATIONSCENTER(2)(5)LOCALSUPPORT1.FIRE/AMBULANCE2.MEDICAL(3)(5)(4)ON-SHIFTEMERGENCYRESPONSEORGANIZATIONLegend:PrimaryNotificationPathway--------AlternateNotificationPathway(1)ViaStateHotRingDownTelephone(HRD)(2)VlaEmergencyNotificationSystem(ENS)(3)Medical8FireEmergenciesOnly,AsNeeded(4)ViaPlantPublicAddressSystem(PA)(5)MaybeperformedbytheDutyCallSupervisor.(EPIP-02A.WPG)ENDOFATTACHMENT1 REVISIONNo.:8PROCEDURENo.:PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORPAGE:28of34EPIP-02ST.LUCIEPLANTATTACHMENT2CRITERIAFOREVACUATION(Page1of1)A.CriteriaforLocalEvacuationTheneedforLocalEvacuationshouldbedeterminedinaccordancewiththefollowingcriteria:EvacuatetheaffectedlocalareainwhichanyofthefollowingconditionsoccuI".1.AreaRadiationMonitorAlarm.2.ContainmentEvacuationAlarm.3.Unevaluateddirectradiationdoserateincreaseinexcessof100mRem/hourabovenormallevels.4.Unexpectedairborneradioactivityconcentrationinexcessof1x10'icroCi/cc.5.Removableradioactivesurfacecontaminationinanunpostedareainexcessof1000dpm/100cm'eta-gammaoveranareaof100ft'.6.Removableradioactivesurfacecontaminationinanunpostedareainexcessof50dpm/100cm'lphaoveranareaof100ft'.7.TheEmergencyCoordinatordeterminesthatasituationexistsforwhichLocalEvacuationisappropriate.B.CriteriaforOwnerControlledAreaEvacuationTheOwnerControlledAreashallbeevacuatedinthefollowingcircumstances:1.SiteAreaEmergency2.GeneralEmergency3.IftheEmergencyCoordinatordeterminesthattheentireOwnerControlledAreashouldbeevacuated.ENDOFATTACHMENT2 REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORPAGE:29of34EPIP-02ST.LUCIEPLANTATTACHMENT3TURNOVERGUIDELINES(Page1of2)UponarrivalattheaffectedControlRoom,theprospectiveEmergencyCoordinatorshouldreviewthefollowingitems/issueswiththeControlRoomEmergencyCoordinator(notinaparticularorder):NOTEThisinformation(1-10below)shouldbereviewedwiththeDCS.1.Typeofaccidentorincident2.Plantstatus3.Equipmentout-of-service4.Operatoractionsunderway5.Radiologicalconditions6.Meteorologicalconditions7.Procedurestatus8.EmergencyPlanactivitiesunderway,includinganyon-siteoroff-siteprotectiveactions9.Conditionsand/ortrendsofconcern10.PersonnelinjuriesorradiationexposuresPriortoleavingControlRoomverifythestatusofthefollowing:1.Emergencyclassification2.Off-sitenotifications REVISIONNO.:PROCEDURENo.:EPIP-02PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORST.LUCIEPLANTATTACHMENT3TURNOVERGUIDELINES(Page2of2)PAGE:30of34BringthefollowingitemstotheTechnicalSupportCenter:1.CopyofRCOlog(entriesfromstartoftheevent)2.Completednotificationforms(StateandNRC)3.OperationsAccountabilityAid(onlyifcompleted)ENDOFATTACHMENT3 REVISIONNO.:PROCEDURENO.:PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORPAGE:31of34EPIP-02ST.LUCIEPLANTATTACHMENT4RE-ENTRYGUIDELINES(Page1of1)CAUTIONAsspecifiedinADM-17.09,Invoking10CFR50.54(x),theEmergencyCoordinator(EC)may(withtheconcurrenceofalicensedsenioroperator)waivere-entryrequirementstoplacetheplantinasafeshutdownconditionormitigatearelease,ifthisimmediateactionisneededtoprotectthehealthandsafetyofthepublic.1~PriortoevacuationandwiththeOperationalSupportCenter(OSC)NOToperational.Re-entryguidelinesdonotapply.2.PriortoevacuationandwiththeOSCoperational.OperatorsinthefieldshouldreturntotheControlRoomsandobtainanElectronicPersonalDosimeter(EPD)fromtheHealthPhysicsEmergencyKitpriortoreturningtofield.183.EvacuationorderedandwiththeOSCNOToperational~Operatoractionsinthefieldmustbeviewedasre-entryactivities.OperatorsshallreturntotheControlRoomsfollowingtheevacuationorder.OperatorsshallobtainanElectronicPersonalDosimeter(EPD)fromtheHealthPhysicsEmergencyKit,ifnotdonepreviously.Re-entryintotheplantrequires:a.TheEC(initiallytheNPS)authorizetheentry.b.Maintenanceofappropriateradiologicalandsafetymeasures.c.Trackingthewhereaboutsoftheteam.4.EvacuationorderedandwiththeOSCoperationala.NLOs,frombothUnits,aretoreporttotheOSConceitisdeclaredoperational.b.Allfieldactivitiesarere-entriesandshallbecoordinatedandcontrolledbytheOSC.ENDOFATTACHMENT4 REVISIONNo.:8PROCEDURENo.:PROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORPAGE:32of34EPIP-02ST.LUCIEPLANT,ATTACHMENT5g,BASISFOREXPOSURELIMITSFOREMERGENCYRESPONSEPERSONNEL(Page1of3)ExposuretoemergencyresponsepersonnelshouldbemaintainedAsLowAsReasonablyAchievable(ALARA).Actionstakenduringanemergencyshouldtakeintoconsiderationtheamountofexposurerequiredtoaccomplishthetaskversusthepotentialbenefittothepublichealthandsafety.Conditionsmaywarrantre-entryintohighradiationareasleadingtoexposureinexcessoftheregulatorylimit.Exceptforrescueofpersonnel(life-savingonly),authorizationmustbegiveninadvancebytheEmergencyCoordinator(EC)inconsultationwiththeTSCHealthPhysicsSupervisor(oralternate).Iftimepermits,theECshouldobtainconcurrencefromtheRecoveryManageriftheEOFisoperational.Inanycase,whereregulatorylimitshavebeenexceededtheECshallnotifytheRMoftheevent.ForthoseremotecircumstancesinvolvinganeventinprogressandobtainingECapprovalwillresultinleavingtheaccidentsceneordecreasethevictim(s)chanceofsurvival,lifesavingactionsmaybeperformedwithoutobtainingECapproval.TheECshallbenotifiedimmediatelyfollowingtherescueoperation.Re-entrypersonnelthathavebeenselected/chosentoexceedregulatoryexposurelimitsshouldbevolunteers'"',broadlyfamiliarwiththerisksinvolved(radiosensitivityoffetuses,effectsofacuteexposures,etc.),whosenormaldutieshavetrainedthemforsuchmissions.EPA400ManualofProtectiveActionGuidesandProtectiveActionsforNuclearIncidents,EPA400-R-92-001statesthat"Toassureadequateprotectionofminorsandtheunbornduringemergencies,theperformanceofemergencyservicesshouldbelimitedtonon-pregnantadults".FPLendorsesthisguidance;however,FPLrecognizesthatitistherightoftheworkertomakethedecisiontoperformasanon-siteemergencyworker,understandingthepotentialrisksinvolved.Since,bytheirverynature,emergencyexposuresrequiringimmediateactionarenotplanned,theyarenotcontrolledasaPlannedSpecialExposure.Dosereceivedfromexposureunderemergencyconditionswillbeaddedtothedosereceivedduringthecurrentyear,priortotheemergency,todeterminecompliancewiththeoccupationaldoselimitsin10CFR20.
REVISIONNo.:PROCEDURENoPROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORPAGE:33of34EPIP-02ST.LUCIEPLANT.ATTACHMENT5BASISFOREXPOSURELIMITSFOREMERGENCYRESPONSEPERSONNEL(Page2of3)Dosesaboveregulatorylimitswillrequirereportingpursuantto10CFR20.2202and20.2203.AnydoseinexcessoftheannuallimitsspecifiedinSection20.1201(a)willbeaccountedforinaccordancewith10CFR20.1206(e).Ifanindividualexceedsanyoftheselimits,thentheindividualwillnotbeavailableforadditionaldoseunder20.1201(a).NOTE1.BothTotalDose(TEDE)andThyroidDose(CDE)shouldbeusedforpurposesofcontrollingexposure.2.Protectiveclothing,includingrespirators,shouldbeusedwhereappropriate.Forthefollowingmissions,theexposurelimitis"':TotalDose"'HYROID"'TEDE)(CDE)Performanceofactionsthatwouldnotdirectlymitigatetheevent,minimizeescalation,orminimizeeffluentreleases.5REM50REMPerformanceofactionsthatmitigatetheescalationtotheevent,rescuepersonsfromanon-lifethreateningsituation,minimizeexposuresorminimizeeffluentreleases.10REM100REMPerformanceofactionsthatdecreasetheseverityoftheeventorterminatetheprocessescausingtheeventinanattempttocontroleffluentreleasestoavoidextensiveexposureoflargepopulations.Al,fpsituation.25REM250REMRfpf~lf-h(Volunteers"'houldbeabovetheageof45.)(5)(5)
REVISIONNo.:PROCEDURENoPROCEDURETITLE:DUTIESANDRESPONSIBILITIESOFTHEEMERGENCYCOORDINATORPAGE:34of34EPIP-02ST.LUCIEPLANT.ATTACHMENT5g,BASISFOREXPOSURELIMITSFOREMERGENCYRESPONSEPERSONNEL(Page3of3)(1)Exposurelimitstothelensoftheeyeare3timestheTotalDose(TEDE)valueslisted.(2)TotalDose(TEDE)isthetotalwholebodyexposurefrombothexternalandinternal(weighted)sources-TotalEffectiveDoseEquivalent.(3)ThyroidDose(CDE)commitmentfrominternalsources-CommittedDoseEquivalent.Thesamedoselimitsalsoapplytootherorgans(CDE),skin(ShallowDoseEquivalent)andextremities(ExtremityDoseEquivalent)~(4)Volunteerswithfullawarenessofrisksinvolvedincludingnumericallevelsofdoseatwhichacuteeffectsofradiationwillbeincurredandnumericalestimatesoftheriskofdelayedeffects.(5)NoupperlimitforTotalDose(TEDE)and/orThyroidDose(CDE)exposurehasbeenestablishedbecauseitisnotpossibletoprejudgetherisksthatonepersonshouldbeallowedtotaketosavethelifeofanother.Also,nospecificlimitisgivenforthyroidexposuresinceintheextremecase,completethyroidlossmightbeanacceptablesacrificeforalifesaved.Thisshouldnotbenecessaryifrespiratorsand/orthyroidprotectionforrescuepersonnelareavailableastheresultofadequateplanning.ENDOFATTACHMENT5 TitleFPLST.LUCIEPLANTEMERGENCYPLANIMPLEMENTINGPROCEDURESAFETYRELATEDProcedureNo.EPIP-04CurrentRevisionNo.EffectiveDate12/28/00ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERResponsibleDepartment:EMERGENCYPLANNINGREVISIONSUMMARY'evision7-RevisedmandatoryfunctionstoincludeclassificationandPARs,removedreferencestoSTA,revisedresponsibilitiesoftheTSCECAssist/LogkeeperandTSCChemistrySupervisor,andmadeeditorialandadministrativechanges.(J.R.Walker,12/07/00)Revision6-ChangedresponsibilityforfillingintheStateNotificationFormfromtheTSCHRDCommunicationtotheTSCECAssist/Logkeeper.Madeeditorialandadministrativechanges.RevisedTSCbriefingguidanceIAWCR00-0429.AddednewPSTTrackingform.(DonnaCalabrese,05/31/00)Revision5-ChangedChemistryminimumstaffpositionfromTSCChemSupvtoTSCDoseAssessor,addressedPMAIbyprovidingalternatenotificationmethods,addedinstructiontoproducelistofEPIPswithcurrentrev.numbers,revisedre-entryworksheet,addedinstructiontocreateconf.bridgeforOPS,andmadeeditorialandadministrativechanges.(J.R.Walker,11/18/99)Revision4-RemovedreferencetotherotatingmaintenanceshiftsupositionofTSCcoordinatorwithOSC.(J.R.Walker,07/01/99)ervisorfillir8$thePiiOCEDUPiKPftODUCTIONRevision7FRGReviewDate12/07/00RevisionFRGReviewDate012/15/97ApprovedByJ.ScaroiaPlantGeneralManagerApprovedByR.G.WestPlantGeneralManagerN/ADesignatedApproverN/ADesignatedApprover(MinorCorrection)ApprovalDate12/15/97ApprovalDate12/07/00SOPSDATEDOCTPROCEDUREDOCNEPIP-04sYsCOMcoMPLETEDITM7
+
REVISIONNO.:PROCEDURENO.:EPIP-04SECTION1.0PURPOSEPROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTTABLEOFCONTENTSPAGE:2of90PAGE.
42.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTS...63.0RESPONSIBILITIES4.0DEFINITIONS5.0INSTRUCTIONSATTACHMENTSATTACHMENT1TSCEMERGENCYRESPONSEORGANIZATIONANDSHIFTSTAFFING.1013ATTACHMENT2TSCECASSIST/LOGKEEPERCHECKLIST........~~~.~.~.....~..14ATTACHMENT2ATYPICALINFORMATIONTOBEINCLUDEDINTHEECLOGBOOK.ATTACHMENT3TSCSUPERVISORCHECKLIST.ATTACHMENT3ATSCEROSHIFTSTAFFINGANDACCOUNTABILITYROSTERATTACHMENT3BTSCMINIMUMSTAFFINGREQUIREMENTSATTACHMENT3CTSCFACILITYBRIEFINGS1617212223ATTACHMENT3DGUIDELINESFORRELOCATIONOFTHETSC....ATTACHMENT4TSCCOMMUNICATORCHECKLISTATTACHMENT4ACOMMUNICATIONSGUIDELINES.............2528.32ATTACHMENT4BSAFETYFUNCTIONSEQUIPMENTSTATUS-UNIT1........39ATTACHMENT5TSCERDADSOPERATORCHECKLIST.ATTACHMENT5AERDADSDATAACQUISITION.43.45 REVISIONNO.:PROCEDURENO.:EPIP-04SECTIONPROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTTABLEOFCONTENTS(continued)PAGE:3of90PAGEATTACHMENTS(continued)ATTACHMENT5BERDADSDATAPOINTS.48ATTACHMENT6TSCADMINISTRATIVESTAFFCHECKLIST......~.~...............56ATTACHMENT7TSCCOORDINATORWITHOSCCHECKLIST~~~.~..~....~....~...59ATTACHMENT7ARE-ENTRYWORKSHEET.ATTACHMENT7BRE-ENTRYLOGATTACHMENT8TSCOPSCOORDINATORCHECKLIST.ATTACHMENT9TSCREACTORENGINEERCHECKLIST.ATTACHMENT9AINITIATINGANDTERMINATINGTHEERDSLINKATTACHMENT10TSCCHEMISTRYSUPERVISORCHECKLIST~.....ATTACHMENT11TSCDOSEASSESSORCHECKLISTATTACHMENT11AOFF-SITERADIOLOGICALASSESSMENT~~~~~~~~~~~~61.68.69~73.~..76...~.78.83ATTACHMENT11BPROTECTIVEACTIONRECOMMENDATIONS.........ATTACHMENT12TSCPROBLEMSOLVINGTEAMCHECKLIST...~...~...~....84..85ATTACHMENT12APSTACTIVITIESLISTATTACHMENT13TSCSECURITYSUPERVISORCHECKLIST........................88 REVISIONNo.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:4of901.0PURPOSE1.1DiscussionThisprocedureprovidesinstructionsfortheactivationandoperationoftheTechnicalSupportCenter(TSC).1.2LocationandDescriptionTheTSCisonthe62footelevationoftheUnit1ReactorAuxiliaryBuilding(RAB).TheTSCislocatedadjacenttotheUnit1ControlRoomandisenclosedinthesamehabitabilityenvelope.TheTSChasemergencycommunicationsequipment,precalculatedemergencydata,pertinentreports,plans,proceduresanddrawingsavailableforuse.ShouldtheUnit1ControlRoomenveloperequireevacuation,alternatelocationsfortheTSChavebeenidentifiedasfollows:SouthServiceBuilding2.NuclearTrainingCenter1.3TSCFunctions1.MandatoryFunctionsA.ClassificationofemergenciesinaccordancewithEPIP-01,ClassificationofEmergencies.NOTEThefollowingtasksbecometheresponsibilityoftheEmergencyOperationsFacilitEOFwhenmannedandfulloerational.B.RelieftotheControlRoomforoff-sitecommunicationstotheStateandlocalagenciesandtheNRCinaccordancewithEPIP-08,Off-siteNotificationsandProtectiveActionRecommendations.C.Performanceofoff-sitedosecalculationsinaccordancewithEPIP-09,Off-siteDoseCalculations,ortheClassAcomputermodel~D.ProtectiveActionRecommendations(PARs)inaccordancewithEPIP-08.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:5of901.3TSCFunctions(continued)2.AdditionalFunctionsA.Managementofemergencymitigationactivities.B.Technicalsupportindeterminingcurrentandprojectedplantstatusandprovidingin-depthdiagnosticandengineeringassistancetotheControlRoom.C.D.Directthere-entryactivitiesoftheOperationalSupportCenter(OSC).CoordinationwiththeEmergencyOperationsFacility(EOF)regardingemergencystatus,correctiveandprotectiveactions,off-siteinterface,radiologicalconditions,coredamageassessment,etc.1.4MinimumStaffing1~ThefollowingisthelistoftheminimumpositionsneededforTSCoperation:EmergencyCoordinatorTSCSupervisorTSCDoseAssessorTSCReactorEngineerTSCElecRep-PST(ProblemSolvingTeam)TSCMechRep-PST(3)TSCCommunicator(HRD,ENS,EOF)1.5QActivationActivationoftheTSCistheresponsibilityoftheEmergencyCoordinator(EC)andisrequiredforanAlertorhigherdeclaredemergency.ArrangementshavebeenmadetostafftheTSCinatimelymanner.1.6OperationsTheTSChassufficientspacetoaccommodatetheFloridaPower8LightCompany(FPL)responseorganizationanddesignatedrepresentativesoftheNuclearRegulatoryCommission(NRC)SiteTeam.Arrangementshavebeenmadewhichallowforcontinuousoperation,asnecessary.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:6of9
02.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTSMOTEOneormoreofthefollowingsymbolsmaybeusedinthisprocedure:IndicatesaRegulatorycommitmentmadebyTechnicalSpecifications,ConditionofLicense,Audit,LER,Bulletin,OperatingExperience,etc.andshallNOTberevisedwithoutFacilityReviewGroupreviewandPlantGeneralManagerapproval.Indicatesamanagementdirective,vendorrecommendation,plantpracticeorothernon-regulatorycommitmentthatshouldNOTberevisedwithoutconsultationwiththeplantstaff.'PIndicatesastethatreuiresasinoffonanattachment.2.1References1.g~St.LuciePlantTechnicalSpecificationsUnit1andUnit2(Section6.10.1)2.St.LuciePlantUpdatedFinalSafetyAnalysisReport(UFSAR)Unit1andUnit23.$2St.LuciePlantRadiologicalEmergencyPlan(E-Plan)4.gsSt.LuciePlantTopicalQualityAssuranceReport(TQAR)5.E-PlanImplementingProcedures(EPIP00-13)6.HP-200SeriesProcedures7.ADM-17.09,Invoking10CFR50.54(x)8.ADM-17.11,10CFR50.59Screening9.St.LuciePlantEmergencyResponseDirectory(ERD)10.QI-17-PSL-1,QualityAssuranceRecords11.ERDADSReactorOperator'sManual(8770-12058)12.St.LuciePlantSevereAccidentManagementGuidelines(SAMGs)13.g4FitnessforDutyRule,10CFR2614.NUREG1394,EmergencyResponseDataSystem(ERDS)
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:7of902.2RecordsRequired1.Thefollowingshallberetainedfollowingaplantemergency:~Checklists,dataandpaperworkgeneratedperthisprocedure.~Logbooksmaintainedduringtheplantemergency.2.g~RecordedinformationshallbeforwardedtoEmergencyPlanningfollowingtheevent,forreviewandarchivalinaccordancewithTechnicalSpecification6.10.1andQI-17-PSL-1.2.3CommitmentDocumentsPMAIPM97-04-142,TrainingDrillCritique1/24/97,(ERDADSscreenmimicsandfullstaffingguidance)2.3.4.5.ConditionReport97-1389,(EmergencySupplies)PMAIPM99-09-017,TrainingDrillCritique7/22/99,(AlternateNotificationMethods)g4PMAIPM96-09-185,ConditionReportCR96-1750(Off-siteNotificationUsingCommercialPhone)ConditionReport00-0429(TSCBriefing)
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:8of903.0RESPONSIBILITIES3.1EmergencyCoordinator(EC)1.TheresponsibilitiesforthispositionareprovidedinEPIP-02,DutiesandResponsibilitiesoftheEmergencyCoordinator.3.2TSCECAssist/Logkeeper2.InitiatesandmaintainstheECLogbook.ProvidesassistancetotheECtoensureECresponsibilitiesaremet,particularlyoff-sitenotificationsandProtectiveActionRecommendations(PARs).3.Performsdutiesasdirected/assignedbytheEC.3.3TSCSupervisor1.ProvidescommandandcontrolofTSCactivities.2.SupervisestheTSCstaffparticularlythecommunicatorsandadministrativepersonnel.3.CoordinatesactivitiestoensureadequatesupportoftheEC.4.Ensurescommunicationsareperformedwithoff-siteagenciesuntiltheEOFisactivated.5.EnsuresthecommunicationflowismaintainedwithinthefacilityandwiththeControlRoom,OSCandEOF.6.Coordinatesfacilitybriefings.7.ArrangesforlongtermoperationoftheTSC.3.4TSCCoordinatorwiththeOSC1~ServesasthecoordinatorwiththeOSC.2.ProvidestheOSCwithrequestsforRe-entryTeams.3.Tracksthere-entryactivitiesoftheOSC.4.UpdatestheTSCregardingOSCteamstatusandcorrectiveactions.
REVISIONNO.:PROCEDURENo.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:9of903.5TSCOPSCoordinatorNOTEThispositionisfilledbytwopersons,onelocatedintheaffectedunit'sControlRoom,theotherintheTSC.1.ProvidesexpertiseinplantoperationstotheECintheTSC.2.ProvidescommunicationsassistancetotheNPSintheaffectedControlRoom.3.Ensurestheunaffectedunit'sControlRoomiskeptapprisedofthestatusoftheemergency.4.MaintainscommunicationflowbetweentheTSCandtheaffectedControlRoomconcerningstatusofoperations.5.ServesasprimarySevereAccidentManagementGuidelines(SAMG)decisionmaker.3.6TSCReactorEngineer1.Monitorscriticalsafetyfunctionsforindicationsofcorestatus.2.AssistsNuclearFuelspersonnelintheEOFinassessmentofcoredamage.3.AssistsinSevereAccidentManagementGuidelines(SAMG)evaluation.3.7TSCChemistrySupervisor1.DirectsdoseassessmentactivitiesintheTSC.2.AssiststheECwithProtectiveActionRecommendations(PARs).3.KeepstheECapprisedofchemistryrelatedissues.4.AssiststheChemistrySupervisorintheOSC.3.8TSCHPSupervisor(TSCHPS)1.TheresponsibilitiesforthispositionareprovidedinHP-200,HealthPhysicsEmergencyOrganization.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:10of903.9TSCSecuritySupervisor1.Establishesandmaintainssiteaccountability.2.ArrangessiteaccessfortheNRCSiteTeam.3.Controlson-sitesecurityoperationsthroughouttheemergency.3.10TSCProblemSolvingTeam(PST)2.3.4.5.EvaluatesplantconditionsandprovidesrecommendationstotheEC.Anticipatescomponentfailuresandaccidentconsequences.Researchesaffectedsystemsandcomponents.Developsmitigationstrategiesand/orcountermeasures.PerformsSevereAccidentManagementGuidelines(SAMG)evaluation.4.0DEFINITIONS4.1FacilityStatus1.Activation-therequesttostaffandestablishanEmergencyResponseFacility(ERF).2.Operational-whensufficientpersonnel(i.e.,minimumstaff)areavailabletoaccomplishmandatoryfacilityfunctionssuchasoff-sitenotificationsanddosecalculations.3.FullyStaffed-thecompletecomplementofpersonnelispresentinthefacility.4.2FPLEmergencyRecallSystem(ERS)-thecall-outsystemusedasameansofoffhourscall-out,asdescribedinEPIP-03,EmergencyResponseOrganization/StaffAugmentation.4.3'ideolink-aclosedcircuitaudio/visualcommunicationslinkoriginatingintheTSCwithfeedstotheOSCandtheEOFallowingtheECbriefingstobeavailableinalltheEmergencyResponseFacilities(ERFs).
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:11of905.0INSTRUCTIONSNOTE~ThissectionprovidesgeneralinformationandinstructionsforallTSCresponders.~Positionspecificchecklistsareincludedasattachmentstothisprocedure.~IndividualsspecificallydesignatedasmembersoftheTSCEmergencyResonseOranizationEROareidentifiedintheERD.5.1Whennotified,TSCemergencyrespondersaretoreporttothefacilityasquicklyaspossible.5.2TheinitialrespondertotheTSCshoulddothefollowing:1.UnlockthefacilitywithakeyfromtheNPSorAssistantNuclearPlantSupervisor(ANPS).Ifthesepersonsareunavailable,breaktheglasstothekeyboxnexttothedoorandremovethekey.2.Turnonthefacilitylights.3.Openallfacilityequipment/documentstoragecabinets.5.3Uponarrivalatthefacility,eachTSCemergencyrespondershouldperformthefollowing:Sign-inon:2.3.4.5.A.thestatusboardontheSouth(rear)wallofthefacilityinthespacecorrespondingtoyourpositionandB.theTSCEROShiftStaffingandAccountabilityRoster.Obtainyourspecificpositionnotebookfromthestoragecabinet.Placeyournameonyourposition(player)badge(locatedinthepositionnotebook)withadryerasemarkerorinanyothernonpermanentmanner.Makeyourworkstation/locationoperational.NotifyyoursupervisorortheTSCSupervisorofyourreadinessstatus.
REVISIONNO.:PROCEDURENo.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:12of905.4g3Onlycontrolledcopiesofnuclearsafety-relatedprocedures,drawingsandotheravailableplantinformationshallbeused.Non-controlleddocumentsordrawingsshouldbeverifiedwithacontrolledcopypriortouseintheTSC.5.5Duringfacilitybriefings,stopwhatyouaredoing,payattentionandcontribute,asrequested.5.6Uponterminationoftheevent:2.AllTSCpersonnelshouldreturntheirworkstations/locationstoanormalstateandassistinrestoringthefacilitytoareadycondition.Collectallsignificantinformationanddocumentation,suchascompletedEPIPsandattachments,logs,notificationformsandothernotesanddatasheets(notboundinthepositionnotebooks),andprovidethismaterialtotheTSCSupervisor.ENDOFSECTION5.0 REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTER11ST.LUCIEPLANTPAGE:13of90ATTACHMENT1TSCEMERGENCYRESPONSEORGANIZATIONANDSHIFTSTAFFING(Page1of1)101EMERGENCYCOORDINATORTSCjSupervisorIIi'IPI3TSCSPIphomnslku~l(locatedIntheControlRoom)113Tscspphcnerasier114TSCERDADSOPer118TSCERDADSTech121TSCAdnrnStall(2)108TSCCcmmunicatcr(3),0(ENSComm)~(HRDComm)0(EOFCOmm)124TSCECAsstJLogkeeper122TSCEPCoordinator(Nctarequiredpcstdcn.)TSCCoordinatorwithOSCI158OSCCoordinatorIwithTSCJ(LocatedIn0>>OSC.)1110ITSCOPSCccrrrr>>rcr~(locatedM8>>CoredRoom.)110TSCOPSCccrdnassr'05~TSCReactorr103TSCHPS112TSCHPComm(2)(HPNComm)(FMTComm)118TSCPSTleader;0107TSCElecRep.PST,0108TSCMechAep-PST(2)(NoteI)IITTSClaoAeP.rST118TSCSROAep-PSTi111TSCDose'rsesscc(rane2)118TSCSecuritySupervtscr(p+srEprpo4/Afretd)Autodialerpositionnumbersarofistedwithpostfiontides.~.30minuteresponsogoal,perNUAEG0654,TaMoB-Io60minuteresponsegoal,perNUAEG0654,TaMeB.tNoteI-onlyonopersoninthoTscMochAoppsTposaionisrequiredasmlrdmumstaff.Note2-TheDoseAssessorfuncdonwlsbeperformedbytheon-shiftChemisL~IndcatesminimumstaffingpoetticnsthatmustbofilMinordertodedarothofaciiiityoperasonal.ENDOFATTACHMENT1 REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:14of90ATTACHMENT2TSCECASSIST/LOGKEEPERCHECKLIST(Page1of2)NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofseuence.A.B.FACILITYACTIVATIONRefertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.FACILITYOPERATIONRemovetheECLogbookfromtheECpositionnotebookandinitiatetheECLog(useAttachment2A,TypicalInformationtobeIncludedintheECLogbook).INITIAL2.3.ReviewtherequirementsofEPIP-02,DutiesandResponsibilitiesoftheEmergencyCoordinator.Stepstooccurcontinuallywhilethefacilityisinoperation:a.b.C.d.e.g.MaintaintheECLogbook.AssisttheECinthecompletionoftherequirementsofEPIP-02.PriortotheEmergencyOperationsFacilitygoingoperational,assisttheECincompletionoftheStateNotificationForm,includingdeterminationofProtectiveActionRecommendations(PARs),asnecessaryinaccordancewithEPIP-08,Off-siteNotificationsandProtectiveActionRecommendations.VerifythattheECapprovesalloff-sitenotificationforms.RemindtheECoftimelimitsfornotificationofoff-siteagencies.Ensurechecklists/paperworkareproperlycompleted.ProvideECasummaryofrecentlogentriesforfacilitybriefings.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT2TSCECASSISTILOGKEEPERCHECKLIST(Page2of2)PAGE:15ofSOB.C.3.(continued)h.SupportECasneededorrequested.AssisttheEmergencyNotificationSystem(ENS)CommunicatorinrespondingtorequestsforinformationfromtheNRC.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.1.Ensuredallfacilityactivitiesclosedout.2.ClosedouttheECLog,returnedtheLogbooktotheECpositionnotebookandreturnedthenotebooktothestoragecabinet.3.5.Ensuredallpaperworkcollected.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheTSCSupervisor.Returnedpositionnotebooktostoragecabinet.ENDOFATTACHMENT2 REVISIONNO.:PROCEDURENo.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:16of90ATTACHMENT2ATYPICALINFORMATIONTOBEINCLUDEDINTHEECLOGBOOK(Page1of1)Maintainingconcise,detailedlogsduringanemergencyeventisimportant.Followingtheevent,allinformationrecordedwillbeneededtoprovideaclearpictureofactionstaken.A.ThefollowinginformationshouldbeincludedintheECLogbook:1.Keyevents(e.g.,classificationchanges,injuries,etc.).2.Statuschangesinequipment,radiologicalconditions,personnel,etc.3.Decisionsmadeoractionstaken.4.Otheritemsofsignificance.B.Logentryrequirements:2.3.4.5.6.Timeofentry.Useink.Write/printlegibly.Useconciseandaccuratewording.Strikethroughandinitialchanges.Donotremovepagesfromthelog.ENDOFATTACHMENT2A REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:17of90ATTACHMENT3TSCSUPERVISORCHECKLIST(Page1of4)NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofseuence.FACILITYACTIVATIONINITIAL2.RefertoSection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.DetermineoperationalreadinessoftheTSCbyverifyingthefollowing:NOTEAttachment3B,TSCMinimumStaffingRequirements,shouldbeusedtodeterminestaffandsuitablealternates.a.Minimumstaffavailable(usetoAttachment3A,TSCEROShiftStaffingandAccountabilityRoster).b.Communicationsequipment,proceduresandothersuppliesareavailable,checkedandreadytouse.CommercialphoneasbackuptoState/CountyandNRCNotifications(DONOTtestcallHRDorENS).~ExtensionphonesinTSC.~Procedure,drawing,techmanualcabinetsunlocked.~Instructpersonneltoverifytheirpositionnotebookproceduresagainstthepostedrevisionnumbers.c.Minimumstaffpreparedtoaccomplishmandatoryfacilityfunctions.3.RecommendtotheECthattheTSCshouldbedeclaredoperational.Operationalat REVISIONNO.:PROCEDURENO.:EPIP-04A.(continued)PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT3TSCSUPERVISORCHECKLIST(Page2of4)PAGE:18of90INITIALB.NOTEg~UnlessauthorizedbytheEC,facilitystaffingshouldbeinaccordancewithAttachment3A,TSCEROShiftStaffinandAccountabilitRoster.4.ReviewadditionalstaffingstatuswiththeEC.5.TSCfullystaffed.6.EnsurethattheEClog,completednotificationformsandchecklistsandanyotherpertinentinformationhavebeenfaxedtotheEOF.FACILITYOPERATION1.InitiatetheTSCLogbook.NOTETheTSCReactorEngineerisresponsibleforestablishingthecommunicationbetweentheSt.LuciePlant'sEmergencyResponseDataAcquisitionandDisplaySystem(ERDADS)andtheNRC'sEmergencyResonseDataSstemERDS.2.3.4.5.6.EnsureERDADSLinkwiththeNRC(ERDS)established/attempted.ObtainfoodandwatersupplyfortheUnit1ControlRoom/TSCpersonnel~ObtainfoodandwatersupplyfortheUnit2ControlRoompersonnel.Arrangeforlongtermstaffing(useAttachment3A,TSCEROShiftStaffingandAccountabilityRoster).AsdirectedbytheEC,initiatestepsforrelocationoftheTSC(useAttachment3D,GuidelinesforRelocationoftheTSC).
REVISIONNo.:PROCEDURENo.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:19of90B.C.ATTACHMENT3TSCSUPERVISORCHECKLIST(Page3of4)(continued)7.Stepstooccurcontinuallywhilethefacilityisinoperation:a.MaintaintheTSCLogbook.b.Manage/superviseactivitiesofTSCCommunicators(HRD,ENS,EOF,HPN,Sound-PoweredPhonetalker,FMT).c.Manage/superviseactivitiesoftheTSCAdministrativeStaff.d.Maintainlownoiselevelsinthefacility.e.CoordinateoverallsupportfunctionsoftheTSC.f.ConductbriefingsinaccordancewithAttachment3C,TSCFacilityBriefings.g.EnsuretheOSCiskeptwellinformedregardingemergencystatusandplantconditions(anaudio/videolinkmaybeusedforthispurpose)~h.EnsuretheEOFiskeptwellinformedregardingemergencystatusandplantconditions(anaudio/videolinkmaybeusedforthispurpose).FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.2.3.4.Allcommunicationslinksterminated.Allcommunicationspaperworkcollected.Allfacilityactivitiesclosedout.Alldocuments,equipmentandsuppliesreturnedtopre-activationconditionand/orlocation.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:20of90C.(continued)ATTACHMENT3TSCSUPERVISORCHECKLIST(Page4of4)INITIAL5.6.7.ClosedoutTSCLogbook.Providedallcompletedpaperwork(notboundinthepositionnotebook(s))toEmergencyPlanning.Returnedpositionnotebooktostoragecabinet.ENDOFATTACHMENT3 REVISIONNO.:PROCEDURENo.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:21of90ATTACHMENT3ATSCEROSHIFTSTAFFINGANDACCOUNTABILITYROSTER(Page1of1)Shift'HoursToPOSITIONMinimumstaffinboldNAMEBADGENO.POSITIONMinimumstaffinboldNAMEBADGENO.EmergencyCoordinatorTSCReactorEngineerTSCCommunicatorTSCCommunicatorTSCMechRep-PSTTSCMechRep-PSTTSCSRORep-PSTTSCHPCommTSCHPSupervisorTSCOPSCoord(inTSC)TSCSPPhonetalker(inTSC)TSCECAssist/LogkeeperTSCERDADSOperatorTSCAdminStaffTSCSecuritySupervisorTSCSupervisorTSCDosoAssessorTSCCommunicatorTSCElecRep-PSTTSCMechRep-PSTTSCILCRep-PSTTSCPSTLeaderTSCHPCommTSCChemistrySupervisorTSCOPSCoord(inControlRoom)TSCSPPhonetalker(inControlRoom)TSCCoordinatorwithOSCTSCERDADSTechTSCAdminStaffTSCEPCoordinator(notrequired)1Longtermstaffing,refertotheSt.LuciePlantEmergencyResponseDirectory(ERD)forpositionalternates.2LongtermstaffingincludestheControlRooms,attachlisttothissheet.3RefertoAttachment3B,TSCMinimumStaffingRequirements,tothisattachmentfortemporaryalternatesforminimumstaffpositions.4TSCCommunicatorpositionfillsthefollowingpositions:a.TSCENSCommunicatorb.TSCHRDCommunicatorc.TSCEOFCommunicatorPositionmayberelievedwhentheEOFgoesoperationalandtakestheleadfordoseassessment.ENDOFATTACHMENT3A REVISIONNo.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:22of90ATTACHMENT3BTSCMINIMUMSTAFFINGREQUIREMENTS(Page1of1)MajorFunctionalArea'eniorMgmt.Rep.Off-siteDoseAssessmentCore/ThermalHydraulicsNotification/CommunicationElectricalMechanicalFacilityCommandandControlPositionTitleandIDNo.EmergencyCoordinator,101TSCDoseAssessor111TSCReactorEngineer,105TSCCommunicator,106TSCElecRep-PST,107TSCMechRep-PST,108TSCSupervisor,102¹inPositionQualifications/TemoraAlternateSeniorManagerwithEmergencyCoordinatorualificationsMemberofChemistDeartmentMemberoftheReactorEngineeringDeartmentorcurrentorriorSTATSCresponderwith-STAorequivalentbackgroundforENSCommunicator-Technical/operationalbackgroundforHRDorEOFCommunicatorElectricalEngineerorElectricalMaintenanceSuervisorMechanicalEngineerorMechanicalMaintenanceSuervisorTSCCoordinatorwithOSCThisfunction(s)maybeaccomplishedduringthefirst75minutesofanemergencybyanindividual(s)meetingthecorrespondinglistedqualifications.TheseEmergencyResponseOrganization(ERO)positionswereestablishedtoaccomplishtheindicatedfunction(s).ENDOFATTACHMENT3B REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:23of90ATTACHMENT3CTSCFACILITYBRIEFINGS(Page1of2)NOTEBriefinsshouldbecarriedbtheVideolink.A.GENERALGUIDELINES2.3.CoordinatedbytheTSCSupervisororhis/herdesignee:a.Establishafrequency(e.g.,approximatelyevery30minutes).Frequencyofbriefingsmaybechanged(e.g.,decreasedduringaprotractedeventorincreasedduringrapidlychangingconditions).b.Setcriteria(i.e.,attendance,noiseandactivitylevel,collectionandcirculationofinformation,etc.).TSCSupervisorshouldannouncethestartofthebriefingandthenturnthebriefingovertotheEC.TSCSupervisorshouldassisttheECduringthebriefing.a.EnsurethattheECreceivesanyupdatedinformation.CoordinatethiswiththeTSCECAssistant/Logkeeper.b.EnsurethattheECrepeatsanyquestionsthatareaskedfromthefloortoensurethattheOSCandEOFmembershaveheardthem.
REVISIONNO.:PROCEDURENo.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:24of90ATTACHMENT3CTSCFACILITYBRIEFINGS(Page2of2)B.GENERALFORMAT-thefollowinginformationshouldbeincludedinfacilitybriefings.NOTEItisnotnecessarytohavealldepartmentrepresentativesparticipateineachbriefing.Usediscretioninthisareatoavoidunnecessaryrepetitionofinformation.Initialstatusandsummarytoinclude:a.Timeofthebriefing.b.EmergencyClassification.c.Plantstatus(affectedunit,unaffectedunit).d.Radiologicalconditions(e.g.,releaseinprogress,contaminatedareas,etc.).e.Statusofprotectiveactions(e.g.,siteevacuation,actionsunderwaybythepublic,etc.).3.4.f.Statusofactivitiesunderwayinthefacility.g.Priorityactivities/primaryfocus.Input/updateinformationfromotherdepartments:a.Operations(includingEOPactions,discussionofSAMGs).b.HealthPhysics(includingfieldmonitoringactivities).c.ReactorEngineering(includingstatusofthereactorcore).d.ProblemSolvingTeam(includingSAMGs).e.TSCCoordinatorwiththeOSC(includingre-entryactivitystatus).Majoractivitiesunderwayinotherfacilities.Concernsorquestions.ENDOFATTACHMENT3C REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:25of90ATTACHMENT3DGUIDELINESFORRELOCATIONOFTHETSC(Page1of3)IfhabitabilityoftheUnit1ControlRoomischallenged(e.g.,duetofire/smoke)andevacuationisrequired,theTSCwillneedtoberelocated.Thefollowingguidelinesareprovidedtoassistinthisendeavor.A.EmerencCoordinatorTransfertheresponsibilitiesoftheECasfollows:a.Classificationoftheemergency-NPSNOTETheEOF,onceoperational,hasresponsibilityforrecommendingprotectiveactionsandforoff-sitenotifications.b.ProtectiveActionRecommendations(PARs)-NPSc.Decisiontonotifyoff-siteofficialsandthecontentofnotification'essages-NPSd.RequesttheunaffectedControlRoomANPStosupporttheNPSinoff-sitenotifications.2.ConductatransferofECresponsibilitieswiththeNPS(viaphoneconversation)oncethealternateTSCispreparedtogooperational.T~6C82.InconjunctionwiththeECandtheTSCHPSupervisor,determinetheappropriateareatorelocatetheTSC.Chooseoneofthefollowing:a.SouthServiceBuildingb.NuclearTrainingCenterDirecttheevacuationbybriefingTSCpersonnelonlocation,travelroute,materialstotakeandanyimmediateactionspriortoleavingthefacility(e.g.,formallyterminatecommunications,turnoffequipment,etc.)
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:26of90(continued)ATTACHMENT3DGUIDELINESFORRELOCATIONOFTHETSC(Page2of3)C.3.Re-establishcommandandcontrolofTSCfunctionsasquicklyaspossible.a.Transfertheresponsibilityforoff-sitenotificationsfromtheunaffectedControlRoom(ifthisresponsibilityhasnotbeentransferredtotheEOF)tothecommunicatorsintherelocatedTSC.AllTSCPersonnel2.3.4.5.Formallydiscontinuecommunications.Gatherpositionnotebooksandotherpertinentmaterials.TravelpertheprescribedroutetothealternateTSClocation.AssistSecurityinre-establishingaccountabilityasquicklyaspossible.Re-establishTSCfunctionsasquicklyaspossible.
REVISIONNO.:PROCEDURENo.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT3DGUIDELINESFORRELOCATIONOFTHETSC(Page3of3)PAGE:27of90SuggestedArrangementsandEquipmentAvailabilityatAlternateTSCLocations:SOUTHSERVICEBUILDINGNUCLEARTRAININGCENTERCommunicationsHRDPhoneENSPhoneHPNPhoneEOFPhoneFMTRadioDoseAssessmentEPareafourthfloorAnycommercialphoneAnycommercialphoneAnycommercialphoneEPareafourthfloorSimulatorAnycommercialphoneAnycommercialphoneAnycommercialphoneSimulatorClassAModelEPareafourthfloorTechnicalTrainingareasecondfloorTSCFunctionsCommandandControlEPareafourthfloorConferenceroomandSupervisorofficessecondfloorProblemSolvingTeamOtherEngineeringareathirdfloorCubiclessecondandfourthfloorConferenceroomsecondfloorCubiclessecondfloorENDOFATTACHMENT3D REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:28of90ATTACHMENT4TSCCOMMUNICATORCHECKLIST(Page1of4)NOTE1.ThischecklistappliestothefollowingCommunicatorpositionsintheTSC:HRDCommunicatorEOFCommunicatorENSCommunicatorSound-poweredPhonetalker(CR/TSC)2.TheresponsibilitiesoftheTSCHPCommunicatorsareprovidedasfollows:HPNCommunicator-inHP-200,HealthPhysicsEmergencyOrganizationFMTComm/Coord-inEPIP-10,Off-siteRadiologicalMonitoring3.Whennecessaryorappropriate,stepsofthischecklistmaybeerformedoutofseuence.A.FACILITYACTIVATION1.RefertoSection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.NOTECommunicatorpositionsshouldbefilledinthefollowingorder:1.HotRingDown(HRD)Phone2.EmergencyNotificationSystem(ENS)3.EOF4.Sound-poweredPhone(CR)5.Sound-oweredPhoneTSC2.Fillingthepositionof3.ReviewappropriateinformationinAttachment4A,CommunicationsGuidelines.INITIAL REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:29of90ATTACHMENT4TSCCOMMUNICATORCHECKLIST(Page2of4)B.FACILITYOPERATIONStepstooccurcontinuallywhilethefacilityisinoperation:HRDCommunications80AssisttheECwithStateandCountynotificationsby:ReviewingtheStateNotificationFormforcompleteness.2.Asnecessary,ensuringProtectiveActionRecommendations(PARs)matchthePARWorksheet(seeNotificationfromtheTechnicalSupportCenterinEPIP-08,Off-siteNotificationsandProtectiveActionRecommendations).C.d.3.EnsuretheEChasapprovedtheform.TransmitthenotificationforminaccordancewithEPIP-08.RequesttheTSCECAssist/Logkeeperlognotificationtimes.FollowingturnoverofnotificationresponsibilitytotheEOFHRDCommunicator,identifyavailabilitytotheTSCSupervisor.Bepreparedtoprovideassistanceasrequested.ENSCommunicationsaSIfnecessary,transmitaninitialNRCNotificationForminaccordancewithEPIP-08.C.d.AtanAlertorhigheremergencyclassification,requesttheNRCtoestablishtheENSconferencebridge.Maintainanopenlineofcommunicationandatransmissionlog.RequesttheTSCECAssist/Logkeeper:1.ProvideassistanceinrespondingtorequestsforinformationfromtheNRC.2.Lognotificationtimes,asappropriate.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:30of90B.ATTACHMENT4TSCCOMMUNICATORCHECKLIST(Page3of4)(continued)ENSCommunications(continued)e.LogallquestionsaskedbyNRC.f.ObtainanswerstoquestionsfromappropriateTSCstaffmember(e.g.,HP,Chemistry,ReactorEngineering,etc.),asnecessary.g.ObtainECapprovalpriortoprovidingadditionalinformationtotheNRC.EOFCommunicationsa.MaintainanopenlineofcommunicationwiththeEOF.b.IfERDADSisoutofservice,useAttachment4B,SafetyFunctionsEquipmentStatusandRadioactiveGaseousSourceTerms,toobtainplantparameterandradiologicaldata(useAttachment4B)viatheSound-poweredPhonetalkerandsharetheinformationwiththeEOF(viatheTSCCommunicatorintheEOF).c.ProvideclarificationofanydiscrepantinformationasrequestedbytheEOF.Sound-poweredPhonetalkeraoProvideanopenlineofcommunicationbetweentheaffectedControlRoomandtheTSC.Providefanstatusfordoseassessment.C.d.Provideclarificationofdataand/orobtainadditionaldataasrequestedbytheTSC.IfERDADSisoutofservice,useAttachment4B,SafetyFunctionsEquipmentStatusandRadioactiveGaseousSourceTerms,toobtainplantparameterandradiologicaldata.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:31of90ATTACHMENT4TSCCOMMUNICATORCHECKLIST~(Page4of4)C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.2.3.4.5.Allcommunicationslinks(HRD,ENS,EOF,Sound-poweredphone)terminated.Allcommunicationspaperworkcollected.Allphoneequipmentreturnedtopre-activationcondition.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheTSCSupervisor.Returnedpositionnotebooktostoragecabinet.ENDOFATTACHMENT4 REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:32of90ATTACHMENT4ACOMMUNICATIONSGUIDELINES(Page1of7)NOTEIfcommunicationsareassociatedwithdrillorexercise,thestatement"Thisisadrill"shouldrecedeandfollowtheactualmessae.A.GENERALGUIDELINES2.3.Alwaysspeakclearly,firmlyandwithnormaltonewhenusinganycommunicationsystem.Thesenderandreceivershouldbeclearlyidentified.Messagetext:Communicationmustbefreeofambiguity.Slangtermsshouldnotbeused.Avoidtheuseofwordsthatsoundalike;forexample,avoidincreaseanddecrease,useraiseandlowerinstead.C.Communicationsmustbespecific.Usenounnamesforplantequipment,notacronyms;forexampleLowPressureSafetyInjectionPumpinsteadofLPSI~Thephoneticalphabetshouldbeusedtoidentifyspecifictrain,bus,channelorequipmentdesignations,notjustletteridentifier;forexample,refertothe1AIphaheaterdrainpump,notthe1Aheaterdrainpump.Thefollowingisthephoneticalphabettobeused:ABCDEFGHIAlphaBravoCharlieDeltaEpsilonFoxtrotGolfHotelIndiaJKLMN0PQRJulietKiloLimaMikeNovemberOscarPapaQuebecRomeoSTUWXYZSierraTangoUniformWhiskeyX-rayYankeeZulud.Thephoneticalphabetshouldnotbeusedforstringedletterreferences,acceptableacronymsorlocationsymbols;forexample,ABbus,ACorDC,TSC,respectively.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:33of90ATTACHMENT4ACOMMUNICATIONSGUIDELINES(Page2of7)A.(continued)4.Acknowledgementandconfirmation(3-waycommunication)-messagesshallbecomprisedofpropertransmission,acknowledgement,andconfirmation.a.Themessageisproperlytransmittedfromtheoriginatortothereceiver.b.Themessagereceivershouldacknowledgethecommunicationbygivingfunctionalrepeat-backtothemessageoriginator.Therepeat-backcanbeprovidedbyeitherparaphrasingorexplainingthemessageinone'sownwords,orbyverbatimrepeat-back.Inallcases,verbatimrepeat-backshouldbeusedforequipmentidentifiers.5.6.7.8.c.Ifthemessagereceiverdoesnotunderstandthemessagehe/sheshouldaskforthemessagetoberepeated.d.Ifanincorrectrepeat-backisgiven,themessageoriginatorshouldimmediatelycorrectthemiscommunicationwithastatementsuchas,'WRONG",followedbyrestatingthecorrectmessage.e.Themessageoriginatorshouldconfirmtheacknowledgement(repeat-back)withastatementsuchas,"Thatiscorrect".TheCallSignshouldbeusedperiodicallywhenusingtheLocalGovernmentRadio(LGR).Priortotransmission,ensurethatinformationhasbeenverifiedandapprovedbytheappropriateauthority,asnecessary.EnsurethatanyincomingpertinentinformationisprovidedtotheTSCSupervisorandtheEmergencyCoordinatorordesignee.Maintaindocumentationofanysignificantinformationprovidedorreceived.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:34of90ATTACHMENT4ACOMMUNICATIONSGUIDELINES(Page3of7)B.COMMUNICATIONSSYSTEMSStateWarningPoint(SWP)HotRingDownPhone(HRD)a.ThisistheprimarycommunicationspathwaytotheStateWarningPointandSt.LucieandMartinCounties.b.Aself-verifyingphonesystemwhichisinitiatedbyenteringthe3digitcodecorrespondingtothedesiredlocationofcontact.Thecodesappearonalistinapull-outdrawerattachedtothebaseofthephoneorintheSt.LuciePlantEmergencyResponseDirectory(ERD).Aconfirmationring-back(doubletone)willbeheardifthedialedterminalissuccessfullycontacted.Whenthepartyanswers,begintransmissionbydepressingthe"push-to-talk"barinthehandset.Releasethe"push-to-talk"bartoreceiveresponse.2.NRCEmergencyNotificationSystem(ENS)a.ThisistheprimarycommunicationspathwaytotheNRC.b.PartoftheNRCEmergencyTelecommunicationsSystem(ETS).Initiatecontactbydialing(direct,noaccesscodeneeded)oneofthephonenumbersprovidedonthephoneorintheERD.ThiswillbecomeanopenlineofcommunicationattheAlertorhigheremergencyclass.TheEOFwilljointheconferencebridge.EOFDirect-lineTelephoneaOThisisadirectlinetotheEmergencyOperationsFacility(EOF)~InitiatecontactbyremovingthehandsetfromthecradlewhichwillcausethephoneintheEOFtoring.Whenthephoneisanswered,begintransmission.ThislinkcanalsobeinitiatedfromtheEOF.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:35of90ATTACHMENT4ACOMMUNICATIONSGUIDELINES(Page4of7)B.(continued)4.Sound-poweredPhonea.Asthenameimplies,thesephone(headsets)arepoweredbysound.b.TheUnit1phonejackislocatedneartheDoseAssessmentStatusBoard;theUnit2phonejackislocatednexttotheChronologyStatusBoardintherearoftheroom.5.c.OncetheheadsetshavebeenconnectedinboththeaffectedControlRoomandtheTSC,transmissioncanbeginbyspeakingintothemouthpiece.CommercialTelephonea.ThisisthefirstalternatecommunicationspathwaytotheStateWarningPointandSt.Lucie,MartinCounties,andNRC.6.b.Dial9foraFortPierceexchange;dial8-1-AreaCodeforallothernumbers.Anauthorizationcodeisneededforlongdistancecalls.EmergencySatelliteCommunicationsSystem(ESATCOM)aSb.ThisisasecondalternatecommunicationspathwaytotheStateWarningPointandSt.LucieandMartinCounties.Toinitiatetransmission,liftthehandsetanddepressthe"push-to-talk"barinthehandset.Wait3-5secondstohearabeepbeforestartingtotalk.Theredlightonthephoneisapowerindicator,whenlit,powerisavailable.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:36of90ATTACHMENT4ACOMMUNICATIONSGUIDELINES(Page5of7)B.(continued)7.LocalGovernmentRadio(LGR)-CallSign:KiloNovemberGolfRomeo8-7-4(KNGR874).a.ThisisthethirdalternatecommunicationspathwaytotheStateWarningPoint.AbackupcommunicationsystemtotheCountiesandindirectlytotheState.Atableradio,MotorolaCommandSeries,providestwochannels,theprimaryF2(39.180MHz,StateChannel1)andthesecondaryF1(39.100MHz,StateChannel2).Channelselectioncanbemadebydepressingthe"F1/F2"button(theradioissettomonitorF2).Theradiocanbeoperatedeitherbydepressingthe"transmit"buttonontheconsoleorberemovingthehandsetanddepressingthe"push-to-talk"barinthehandset.The"xmit"lightislitduringtransmission.(Preferenceshouldbegiventousingthehandset).SatelliteTelephonea.Instructionsforuseofthesatellitetelephoneareprovidedinthephone'sbriefcase.b.ThephoneisstoredinasupplycabinetintheTSC.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:37of90ATTACHMENT4ACOMMUNICATIONSGUIDELINES(Page6of7)C.tt3AlternateStateWarninPointNotificationMethods(recommendedformat):NOTEUseofthecommercialtelephoneasanalternatenotificationmethodrequirescallbackverificationfromtheStateWarningPoint.UseofESATCOMorLocalGovernmentRadioasanalternatenotificationmethodshouldincludeacallbackverificationnumberifavailable(e.g.,cellularhone.Alternate1-CommercialphoneCalltheStateWarningPointusingthephonenumberintheSt.LuciePlantEmergencyResponseDirectory(ERD).Announce"ThisisSt.LucieUnitNuclearPlantwithanemergencydeclaration.MycallbacknumberisHangupthephoneandstandbyforthecallback.WhentheStateWarningPointgivesthego-ahead,providetheinformationfromtheStateofFloridaNotificationMessageForm.$4RequestcallbacktoverifythatStateWarningPointhasnotifiedSt.LucieandMartinCountiesandtheBureauofRadiationControl.2.Alternate2-ESATCOMHolddownthebuttononthehandsetandwait3-5secondstohearabeepbeforeyoustarttalking.Thismustbedoneeachtimeyoutalk.Announce"StateWarningPoint,thisisSt.LucieUnit,"thenreleasethebuttoninordertolisten.WhentheStateWarningPointacknowledges,announce"StateWarningPitttSt,LiUit~lfiipt~lifWhentheStateWarningPointgivesgo-ahead,providetheinformationfromtheStateofFloridaNotificationMessageForm.Announce"St.Lucieclear"attheendoftheconversation.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:38of90C.(continued)ATTACHMENT4ACOMMUNICATIONSGUIDELINES(Page7of7)3.Alternate3-LocalGovernmentRadio(LGR)communicationtoSt.LucieandMartinCountyEmergencyOperationsCenters(EOCs)withrelaytotheStateWarningPoint.Onchannel2,contactthecountyEOCsbydepressingthetransmitbuttonandannouncing"St.LucieCountyEOC,thisisSt.LucieNuclearUnit.Over."WhenSt.LucieCountyreplies,directthemtostandbywhileyoucontactMartinCounty.Whenbothcountiesareonline,announce"MartinandSt.LucieCountyEdd,idtdf.tI~IlittdItgFI~IFt.ItdtggftttgttfglIdNotificationMessageForminformationwhenyouarereadytocopy.Over."Whenthecountiesgivethego-ahead,providetheinformationfromtheStateofFloridaNotificationMessageForm.Endtheconversationbyannouncing"ThisisSt.LucieUnitKNGR874,overandout."ENDOFATTACHMENT4A REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:39of90ATTACHMENT4BSAFETYFUNCTIONSEQUIPMENTSTATUS-UNIT1(Page1of4)ERDADSSF1ScreenMimicPLANTPARAMETERSREACTORPWR(WR)REACTORVSLLEVELRCSPRESSURE(NR)PSIA(1500-2500)RCSPRESSURE(LR)PSIA(0-1600)PRESSURIZERLEVELCETTEMPERATUREDEGFHOTLEGATEMPDEGFHOTLEGBTEMPDEGFCOLDLEGA1TEMPDEGFCOLDLEGA2TEMPDEGFCOLDLEGB1TEMPDEGFCOLDLEGB2TEMPDEGFLMTNGSBCOOLMRGNDEGFS/GAPRESSUREPSIGS/GALEVEL(WR)S/GBPRESSUREPSIGS/GBLEVEL(WR)/oCNTMTPRESS(WR)PSIGCONTAINMENTTEMPDEGFSAFEGUARDSPUMPSTATUSHPSIAHPSIBLPSIALPSIBCHRGACHRGBCHRGCCCWACCWBCCWCAFWAAFWBAFWC(ON/OFF)ON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFAUXFEEDFLOWPMABCA1A2B1B2BIASASIASBMSISAMSISBYES/NOYES/NOYES/NOYES/NOA1A2B1B2S~ll'SLEVEL'1A2B1B2SIT'SPRESSPSIAA1A2B1B2SAFEGUARDSSIGNALSCONTAINMENTCNTMTCOOLERACNTMTCOOLERBCNTMTCOOLERCCNTMTCOOLERDON/OFFON/OFFON/OFFON/OFFPRESSUREPSIGLEVEL(NR)FEET((-7)TO0)LEVEL(WR)FEET((-1)To26)TEMPERATUREATMOSPHEREDEGFSUMPDEGFRADIATIONLEVELCHHRMR/HRPOST/LOCAMR/HRPARTICULATECPMGASEOUSCPMHYDROGENCONCENTRATIONAANALYSERBANALYSERCONTAINMENTCOOLERS(ON/OFF)RWTFEETCSTFEETBAMTABAMTBHVACSTATUS(ON/OFF)HVE4AHVE4BHVE8AHVE8BHVE9AHVE9BHVE10AHVE10BON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFBALANCEOFPLANTELECTRICALPLANT4.16KVA3VOLTS4.16KVB3VOLTSDIESELGENERATORSD/GAVOLTSD/GAAMPSD/GBVOLTSD/GBAMPSTANKSTATUS REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:40of90ATTACHMENT4BRADIOACTIVEGASEOUSSOURCETERMS-UNIT1(Page2of4)ERDADSRG1ScreenMimicWINDSPEEDWINDDIRECTIONAIRTEMPDIFFTEMP10METERMPHDEGDEG57.9METERMPHDEGDEGFDEGF/50METERCHANNELMAINSTEAMVALUEUNITSCHANNELCONTAINMENTVALUEUNITS05-01AMAINSTMMR/HR58AHIRANGER/HR05-02BMAINSTMMR/HR59BHIRANGER/HRPRESSUREPSIGCHANNEL'CCS1AVALUE02-05LOWRANGE02-07MIDRANGE02-09HlRANGE02-10FLOWUNITSCHANNELuC/cc01-05uC/cc01-07uC/cc01-09SCFM01-10PLANTVENTVALUELOWRANGEMIDRANGEHlRANGEFLOWUNITSuC/ccuC/ccuC/ccSCFMCHANNELECCS1BVALUEUNITSCHANNELFUELBLDG03-05LOWRANGEuC/cc04-05LOWRANGE03-07MIDRANGEuC/cc04-07MIDRANGE03-09HlRANGEuC/cc04-09HlRANGE03-10FLOWSCFM04-10FLOWVALUEUNITSuC/ccuC/ccuC/ccSCFM REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT4BRADIOACTIVEGASEOUSSOURCETERMS-UNIT2(Page3of4)ERDADSSF2ScreenMimicPAGE:41of90PLANTPARAMETERSREACTORPOWER(WR)RXVSLHEADLEVEL'/oRXVSLPLENUMLEVEL'/oRCSPRESSURE(NR)PSIA(1500-2500)RCSPRESSURE(LR)PSIA(0-750)PRESSURIZERLEVELCETTEMPERATUREDEGFHOTLEGATEMPDEGFHOTLEG8TEMPDEGFCOLDLEGA1TEMPDEGFCOLDLEGA2TEMPDEGFCOLDLEG81TEMPDEGFCOLDLEG82TEMPDEGFLMTNGSBCOOLMRGNDEGFS/GAPRESSUREPSIGS/GALEVEL(WR)'/oS/G8PRESSUREPSIGS/G8LEVEL(WR)CNTMTPRESS(WR)PSIGCONTAINMENTTEMPDEGFSAFEGUARDSPUMPSTATUSHPSIAHPSI8LPSIALPSI8CHRGACHRG8CHRGCCCWACCW8CCWCAFWAAFW8AFWC(ON/OFF)ON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFAUXFEEDFLOWGPMA8CBIASABIAS8MSISAMSIS8YES/NOYES/NOYES/NOYES/NOA1A28182LPSIFLOWGPMA1A28182~Sll'SLEVEL'1A28182SIT'SPRESSPSIAA1A28182SAFEGUARDSSIGNALSCNTMTCOOLERACNTMTCOOLER8CNTMTCOOLERCCNTMTCOOLERDON/OFFON/OFFON/OFFON/OFFCONTAINMENTPRESSUREPSIGLEVEL(NR)FEET((-7)TO0)LEVEL(WR)FEET((-1)TO26)TEMPERATUREATMOSPHEREDEGFSUMPDEGFRADIATIONLEVELCHHRMR/HRPOST/LOCAMR/HRPARTICCPMGASEOUSCPMHYDROGENCONCENTRATIONAANALYSER8ANALYSERCONTAINMENTCOOLERS(ON/OFF)4.16KVA3VOLTS4.16KV83VOLTSDIESELGENERATORSD/GAVOLTSD/GA~MPSD/G8VOLTSD/G8AMPSTANKSTATUSRWTFEETCSTFEETBAMTABAMT8HVACSTATUS(ON/OFF)HVE4AHVE48HVE6AHVE68HVE9AHVE98HVE10AHVE108ON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFBALANCEOFPLANTELECTRICALPLANT REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:42of90ATTACHMENT48RADIOACTIVEGASEOUSSOURCETERMS-UNIT2(Page4of4)ERDADSRG2ScreenMimicWINDSPEEDWINDDIRECTIONCURRENTTEMPDIFFTEMP10METERMPHDEGDEGFDEGF57.9METERMPHDEGDEGFCHANNELMAINSTEAMVALUEUNITSCHANNELCONTAINMENTVALUEUNITS631AMAINSTMMR/HR40AHlRANGER/HR632BMAINSTMMR/HR41BHlRANGER/HR633BACKGROUNDMR/HRPRESSUREPSIGCHANNEL601602603604ECCS2ALOWRANGEMIDRANGEHIRANGEEFFLUENTVALUEUNITSCHANNELuC/cc621uC/ccuC/cc623uC/SEC624PLANTVENTVALUEUNITSLOWRANGEuC/ccMIDRANGEuC/ccHlRANGEuC/ccEFFLUENTuC/SECCHANNEL611612613614ECCS2BVALUEUNITSLOWRANGEuC/ccMIDRANGEuC/ccHlRANGEuC/ccEFFLUENTUC/SECENDOFATTACHMENT48 REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT5TSCERDADSOPERATORCHECKLIST(Page1of2)PAGE:43of90NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofseuence.A.FACILITYACTIVATION1~RefertoSection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.B.FACILITYOPERATIONINITIALCAUTIONEnsuredataisbeingcollectedfortheaffectedunit.EachunithaspredesinatedERDADSterminals.CheckoutERDADSterminalsanddetermineoperabilitystatus.IfERDADSisinoperableorprintoutsarenotavailable,ThenassisttheSound-poweredPhonetalkerincollectingplantparameterandradiologicaldatabycompletingAttachment4B,SafetyFunctionsEquipmentStatusandRadioactiveGaseousSourceTerms.2.Stepstooccurcontinuallywhilethefacilityisinoperation:CallupEPIPscreensandadditionaldataasrequested,refertoAttachment5A,ERDADSDataAcquisition.ProvidethefollowingprintoutstotheTSCAdministrativeStaff.1.SafetyFunctionsEquipmentStatus(SF1/2).2.RadioactiveGaseousSourceTerms(RG1/2).3.Otherscreensasrequested.C.SupportdoseassessmentbyprovidingrequesteddatafromERDADS.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:44of90B.C.ATTACHMENT5TSCERDADSOPERATORCHECKLIST(Page2of2)2.(continued)d.ObserveERDADSdataduringintervalbetweenreportprintingforsignificantchangesandtrends,reportchangestoappropriatemembersoftheTSCstaff.e.RefertoAttachment5B,ERDADSDataPoints,foradescriptionofERDADSdatapoints.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.2.3.ERDADSsystemreturnedtopreactivationcondition.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheTSCSupervisor.Returnedpositionnotebooktostoragecabinet.ENDOFATTACHMENT5 REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:45of90DATAACQUISITIONATTACHMENT5AERDADSDATAACQUISITION(Page1of3)A.ERDADS-EmergencyResponseDataAcquisitionandDisplaySystem,thefollowinginformationisavailableonthedisplayscreensindicated.MeteorologicalData-Display:SMD(SiteMeteorologicalData)2.PlantParameterData-CAUTION.Certainparameters(e.g.,fanstatus)availableonUnit2areNOTavailableonUnit1.3.4.Display:intheTSC-SF(1/2)(SafetyFunctionsandEquipmentStatus)RadiologicalData-Display:RG(1/2)(RadiationGaseousSourceTerms)RBS(HealthPhysicsEvaluationScreen-containmentradiationlevelsandtrends)R11(AreaRadiationMonitors,Unit1)R21(AreaRadiationMonitors,Unit2)ChemistryData-Display:R12(S/GBlowdown,SteamJetAirEjector,Unit1)R22(S/GBlowdown,SteamJetAirEjector,Unit2)
REVISIONNO.:PROCEDURENo.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:46of90ATTACHMENT5AERDADSDATAACQUISITION(Page2of3)I.DATAACQUISITION(continued)A.(continued)5.Toaccessdata-a0b.C.d.Press"CLEAR"Typein"PupUnit(1/2)"Press"EXEC"ute,topofscreenwillread"Unitchangeiscomplete"or"CurrentUnitissameasenteredUnit"Press"EPIP"B.e.The"PAGEUP"and"PAGEDOWN"keyswillcausethefollowingdisplaysequence:SMD-RG(1/2)-SF(1/2)-RBS-EF(1/2)-SMD6.Togodirectlytoascreen-a.Press"CLEAR"b.Typeinscreendesignation,e.g.,"RG1"c.Press"DISPLAY"Sound-poweredPhonetalker-TheSound-poweredPhonetalkercanbeutilizedasaprimarysourceofinformationorasanalternatemethodtoERDADS.1.Primarysource-statusoffansneededfordoseassessmentexhaustfans6,7,8,9,10,15,16and17.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:47of90ATTACHMENT5AERDADSDATAACQUISITION(Page3of3)II~ERDADS-COLOR/SYMBOLCONVENTIONSColor/SmbolNumericvalueinwhiteondarkgreenbackgroundDatavalueisvalidandwithintheinstrumentrange.Numericvalueblinking(yellowonblue/redonwhite)Valuemaybeyellowonbluebackground(urgentalarm)orredonwhitebackground(criticalalarm),indicatesanalarmsettinghasbeenexceeded,thealarmmustbeacknowledgedintheControlRoom(operatorsareunabletoacknowledgeERDADSalarmsintheSimulatorControlRoom),thevaluewillcontinuetoblinkuntilacknowledged;thevaluewillcontinuetoupdate."BAD"(blueonwhite)Precededbyanumericvalueinwhiteonabluebackgroundsignifyingasuspectvalueindicatingthatoneorseveralinputstothiscompositepointis/areoutofinstrumentrange,whenallinputstothepointareoutofrangetheword"BAD"replacesthenumericvalue."FAILED"Pointisfromasingleinstrumentandthevalueisoutofrange."NODATA"PointdoesnothaveinputtoERDADS,usuallypointavailableononeunit,butnottheother."BasedonTable4.1intheERDADSReactorOperator'sManual(8770-12058)ENDOFATTACHMENT5A REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:48of90ATTACHMENT5BERDADSDATAPOINTS(Page1of8)ThefollowingdatapointdescriptionsforSt.LuciePlantcorrespondwiththedatanormallytrackedontheplantparametersstatusboard.ConsultERDADSManual,asnecessary,forverificationofpointIDs,pointnamesordescriptioninformation.POINTDESCRIPTIONAvg.RCSTHot(HLAandHLB)(deg.F)PTIDQTA541-1/2POINTNAMETYPECALCULATIONAverageNOTESThisparameteristheaverageoftheAand'Bsteamgeneratorinlettemperature.Itisalsoreferredtoastheaveragehotlegtemperature.TheIndividualAand"B"hotlegtemperaturesarederivedbychoosingbetweencurrentnarrowandviiderangesensorvalues.Thechoicedependsonthecurrentvalues,qualitiesanddirectionoftheratesofchangeoftheinstrumentationvalues,aswellastwopairsofoverlappingswitchinglimitsandthemostrecentrangeutilized.Theoutputsfromthecalculationconsistofthechoiceofrange,theassociatedvalueandrateofchangetogetherviiththeualitofeach.RCSPressureWR(psia)QA0501-1/2RCSPressureAverageThisparameterisaReactorCoolantSystem(RCS)viiderangeInstrument.ItderivedfromPressurizerPressuresignalsPT1107-2andPT1108-2whicharelinear.Thesesignalsareprocessedbyanaveragewithexpandedqualityalgorithm.Thisfunctionobtainstheaverageofallvalueswithagoodstatus.Italsosetsthequalityoftheresultbasedonthenumberofvalueswithgoodstatus,versusthetotalnumberofInputs.Thepossiblestatusvaluesare:Greaterthan50%ofinputshavegoodstatus,resultisgood.Onlyonegoodvalueandthetotalinputsare3ormore,theresultispoor.Whentherearenogooddatavalues,buttherearesomeviithpoororsuspect,theresultispoor.Theresultissuspectforallothercasesexceptallbad,inthiscasetheresultisbad.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:49of90ATTACHMENT5BERDADSDATAPOINTS(Page2of8)POINTDESCRIPTIONRCSPressurizerLevel(%)ChargingFlowtoRegenHxGPMSubcoolingMargin(deg.F)PTIDQA0001-1/2FT2212-1/2QA0005-1/2POINTNAMEPRZRLVLRCSCHG/MUSubmarginTYPECALCULATIONAverageN/AMinimalNOTESThisparameterispressurizerlevel.ItIsderivedfromPressurizerLevelcontrolsignalsLT1110X-2andLT1110Y-2whicharelinear.Thesetwosignalsaroprocessedbyanaveragewithexpandedqualityalgorithm.Thisfunctionobtainstheaverageofallvalueswithagoodstatus.Italsosetsthoqualityoftheresultbasedonthenumberofvalueswithgoodstatus,versusthetotalnumberofInputs.Thopossiblestatusvaluesare:~Greaterthan50%ofallinputshavegoodstatus,resultisgood.~Onlyonegoodvalueandthetotalinputsare3ormore,theresu!tispoor.~Whentherearenogooddatavalues,buttherearesomewithpoororsuspect,theresultIspoor.~Theresultissuspectforallothercasesexceptailbad,inthiscasetheresultisbad.Thotopoftheheatersis73.98inchesabovetholowertocenterline.Thisparameterisreactorcoolantsystemmakeupflow.Itisconvertedtoengineeringunitsusingalineareuation.Thisparameterisderivedfromeightsubcooledvalues,TMARHEAD-A-1/2,TMARRCS-B-1/2,TMARUR-A-1/2,TMARHEAD-B-1/2,TMARCET-A-1/2TMARUR-B-1/2,TMARRCS-A-1/2andTMARCET-B-1/2,whichareprovidedbytheQualifiedSafetyParameterDisplaySystem(QSPDS).Thoyaroprocessedbyasignalauctioneerlngminimumalgorithm.Thisfunctionfindsthehighestusabledatavalueinaspecifiedgroup.Eachdatavalueofthogroupanditsqualityisexaminedandthefollowingquantitiesareobtained:1.Lowestusabledatavalue,2.Pointnumberofthelowestusabledatavalue,3.Numberofusabledatavalues,and4.Lowestqualityoftheusabledata.Fortwoormoreusabledatavalues,theresultisthehighestusablevalueandthoqualityistholowestqualityoftheusabledata.Foronlyoneusabledatavalue,theresultissottothatvalueandthequalityispoor.Fornousabledata,thevalueofthoresultissettothehighestofallthe(bad)dataandthequalityIsbad.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:50of90ATTACHMENT5BERDADSDATAPOINTS(Page3of8)POINTDESCRIPTIONPTIDPOINTNAMETYPECALCULATIONNOTESAvg.CoreExitQA0003-1/2Temperature(deg.F)Temp.CoreEx.AverageThisparameterisderivedfrom45Unit1detectors,or56Unit2detectorslocatedjustabovetheupperfuelalignmentplate.TheQualifiedSafetyParameterDisplaySystem(QSPDS)providesthevalues.Theyareprocessedbyanaveragewithexpandedqualityalgorithm.Thisfunctionobtainstheaverageofallvalueswithagoodstatus.Italsosetsthequalityoftheresultbasedonthenumberofvalueswithgoodstatus,versusthetotalnumberofinputs.Thepossiblestatusvaluesare:Greaterthan50%ofallInputshavegoodstatus,resultisgood.Onlyonegoodva!ueandthetotalinputsare3ormore,theresultIspoor.Whentherearenogooddatavalues,buttherearesomewithpoororsuspect,theresultispoor.Theresultissuspectforallothercasesexceptallbad,inthiscasetheresultisbad.ReactorVesselLovel(%)Unit1:QA0004-1Unit2:RLEVH-2RLEVP-2MinimumThereactorvessellevelforUnit1QA0004-1isderivedfromthereactorvessellevelsRLEV-A-1andRLEV-B-1whichareprovidedbytheQualifiedSafetyParameterDisplaySystem.TheERDADSselectthelowestofthetwovalues.Foronlyonegooddatavalue,theresultissettothatvalueandthequalityispoor.ThereactorvessellevelforUnit2isdisplayedasreactorplenumlevelRLEVPB-2andreactorheadlevelRLEVHB-2whichisprovidedbytheB'ideQualifiedSafetyParameterDisplaySystem(QSPDS).ThesetwoparametersaredisplayedwithnocalculationsbeingperformedbytheERDADScomputersystem.TheQSPDSobtainsthesevaluesfromtheheatedandunheatedjunctionthermocoupleslocatedInsidethereactor.Theyarepositionedbetweentheheadanduerfuelalinmentlateinthereactorinternals.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:51of90ATTACHMENT5BERDADSDATAPOINTS(Page4of8)POINTDESCRIPTIONReactorVesselLevel%(continued)PTIDPOINTNAMETYPECALCULATION~~norLocation(*in.tofuel)Levely~linme~nf+eQgqmen~}Valueif~Unve~red'NOTESUnit1LevelInformation:HeadandPlenumtogetherNone12345678186N1443/8108715/8505/8295/8195/8105/8201918141075710080614329191270Unit2LevelInformation:HeadandPlenumtogetherSensorLocation('n.tofuel)Level~alinmenttate~Sement'alueif~Untmvered'one123None45678170/i140~/i1111/8985/8745/8535/8325/8125/8522820182120192210048200100826141220 REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:52of90ATTACHMENT5BERDADSDATAPOINTS(Page5of8)POINTDESCRIPTIONPTIDPOINTNAMETYPECALCULATIONNOTESHPSITotalFlow(GPM)LPSITotalFlow(GPM)HSIITLF-1/2HPSIFlowQA0908-1/2LPSIFlowSumSumThisparametermeasurestotalHPSIflowandisderivedfromHPSIHeaderFlowsignalsFT3311-1/2,FT3321-1/2,FT3331-1/2andFT3341-1/2whicharesquareroots.Thesignalsareprocessedviithasumofinputsalgorithm.Thisfunctionobtainsthealebraicsumofvaluesviithaoodstatus.ThisparametermeasurestotalLPSIflowandisderivedfromLPSIHeaderFlowsignalsFT3312-1/2,FT3322-1/2,FT3332-1/2andFT3342-1/2whicharesquareroots.ThesesignalsareprocessedbyanalgorithmwhichprovidesasumoftheInputs.Thisfunctionobtainsthealgebraicsumofvaluesviithaoodstatus.ContainmentTemp.(deg.F)ContainmentPressureWR(pslg)TE07-3B-1/2QA0507-1/2CntmntTempCntmntPressN/AAverageThisparameterisacontainmenttemperatureinstrument.Itisconvertedtoengineeringunitsusingalineareuatlon.ThisparametermeasurescontainmentpressureandIsawiderangeindicator.ItisderivedfromWideRangeContainmentPressuresignalsPT07AA1-1/2andPT07PB1-1/2whicharelinear.Theyareprocessedbyanaverageviithexpandedqualityalgorithm.Thisfunctionobtainstheaverageofallvalueswithagoodstatus.Italsosetsthequalityoftheresultbasedonthenumberofvalueswithgoodstatus,versusthetotalnumberofInputs.Thepossiblestatusvaluesare:Greaterthan50%ofallinputshavegoodstatus,resultisgood.Onlyonegoodvalueandthetotalinputsare3ormore,theresultispoor.Whentherearenogooddatavalues,buttherearesomewithpoororsuspect,theresultIspoor.Theresultissuspectforallothercasesexceptallbad.inthiscasetheresultisbad.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:53of90ATTACHMENT5BERDADSDATAPOINTS(Page6of8)POINTDESCRIPTIONContainmentSumpLevelWR(Ft.)PTIDQA0008-1/2POINTNAMECntmntSmpWRTYPECALCULATIONMaximumNOTESThisparameterisacontainmentsumpwiderangeinstrument.ItlsderivedfromContainmentSumpLevelsignalsLT07-13A-1/2andLT07-13B-1/2whicharelinear.Theyareprocessedbyasignalauctioneeringmaximumalgorithm.ThisfunctionfindsthehighestusabledatavalueInthespecifiedgroup.Eachdatavalueofthegroupanditsqualityisexaminedandthefollowingrulesareused.Fortwoormoreusabledatavalues,theresultisthehighestusabledatavalueandthequalityisthelowestqualityoftheusabledata.Foronlyoneusabledatavalue,theresultissettothatvalueandthequalityispoor.ContainmentHydrogen(%)CH2-1/2H2Conc.AverageFornousabledata,thevalueoftheresultissettothehighestofallthe(bad)dataandthequalityisbad.Thisparameterisacontainmenthydrogenaverageconcentrationmeasurement.ItisderivedfromHydrogenConcentrationsignalsA-HYDROGEN-1/2andB-HYDROGEN-1/2whicharelinear.Thesesignalsareprocessedbyanaveragewithexpandedqualityalgorithm.Thisfunctionobtainstheaverageofallvalueswithagoodstatus.Italsosetsthequalityoftheresultbasedonthenumberofvalueswithgoodstatus,versusthetotalnumberofinputs.Thepossiblestatusvaluesare:~Greaterthan50%ofallinputshavegoodstatus,resultisgood.SGLevelAWRLT9012-1/2(%)SGLevelBWRLT9022-1/2(%)SGLevelASGLevelBN/AN/A~Onlyonegoodvalueandthetotalinputsare3ormore,theresultisoor.ThisparameteristheA"steamgeneratorwiderangelovelinstrument.ItIsconvertedtoengineeringunitsusingalinearequation.LTCL=LowerTapCenterLine.Thelowertapis19.5InchesabovethebottomoftheUtubes.Thisparameteristhe"B'teamgeneratorwiderangelevelinstrument.Itisconvertedtoengineeringunitsusingalinearequation.LTCL=LowerTapCenterUne.Thelowertapis19.5inchesabovethebottomoftheUtubes.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:54of90ATTACHMENTGBERDADSDATAPOINTS(Page7Of8)POINTDESCRIPTIONPTIDPOINTNAMETYPECALCULATIONNOTESSGPressureAQA0021-1/2(psig)SGPressureBQA0022-1/2(psig)RefuelingRWTAL-1/2WaterTankAvg.Level(Ft.)SGPres./ASGPres./BBWSTLevelRedundantSensorAlgorithmRedundantSensorAlgorthimAverageThisparameteristheAsteamgeneratorpressure.ItisderivedfromthreeSteamGeneratorPressureSignals,PT8013A-1/2,PT8013B-1/2andPT8013C-1/2,whicharelinear.Thesesignalsareprocessedbyaredundantsensoralgorithm.Thisfunctionobtainstheaverageofthecurrentvaluesthathaveagoodstatusandareclosetothestatisticalma'orit.ThisparameteristheBsteamgeneratorpressure.ItisderivedfromthreeSteamGeneratorPressureSignals,PT8023A-1/2,PT8023B-1/2andPT8023D-1/2,whicharelinear.Theses!goalsareprocessedbyaredundantsensoralgorithm.Thisfunctionobtainstheaverageofthecurrentvaluesthathaveagoodstatusandareclosetothestatisticalma'oriThisparametermeasuresrefuelingwatertanklevel.Itisderivedfromthreeinputs.TheyareLT07-2A-1/2,LT07-2B-1/2andLT07-2C-1/2.Thesepointsareprocessedbyanaveragewithexpandedqualityalgorithm.Thisfunctionobtainstheaverageofallvalueswithagoodstatus.Italsosetsthequalityoftheresultbasedonthenumberofvalueswithgoodstatus,versusthetotalnumberofinputs.Thepossiblestatusvaluesare:~Greaterthan50%ofallinputshavegoodstatus,resultisgood.~OnlyonegoodvalueandthetotalInputsare3ormore,theresultispoor.~Whentherearenogooddatavalues,buttherearesomewithpoororsuspect,theresultispoor.~TheresultIssuspectforallothercasesexceptallbad,inthiscasetheresultisbad.Tankbottomreferstozeroallons.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:55of90ATTACHMENT5BERDADSDATAPOINTS(Page8of8)POINTDESCRIPTIONCHRRM.Channel(R/HR)PTIDUnit1:RE26-58-1(AChannel)RD26-59-1BChannel)Unit2:RIM2&40-2(AChannel)RIM2&41-1BChannelPOINTNAMECntmnt.RadTYPECALCULATIONMaximumNOTESThehighcontainmentradiationInstrumentsforUnit1arethe"A"sidemonitorRE26-58-1andthe"B"sidemonitorRE26-59-1.Thesemonitorsareonlyrangecheckedandflaggedbadifoutofrange.Bothdetectorsarelocatedatthe90footcontainmentelevationandarepositionedat0and180degrees.ThehighcontainmentradiationinstrumentsforUnit2aretheA"sidemonitorRIM2840-2andtheB"sidemonitorRIM2&41-2.Thesemonitorsareonlyrangecheckedandareflaggedbadifoutofrange.Bothdetectorsarelocatedatthe90footcontainmentelevationandarepositionedat0and180degrees.ENDOFATTACHMENT5B REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:56of90ATTACHMENT6TSCADMINISTRATIVESTAFFCHECKLIST(Page1of3)NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofseuence.A.FACILITYACTIVATIONRefertoSection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.INITIAL2.Verifyproceduresbypostingrevisionnumbersonthestatusboard.Postallprocedures(EPIP,HP,Chem.).ConsultControlCopy5intheTSCdocumentcabinetsorfollowthestepsbelowtoprintoutanEPIPlist:InLotusNotes,clickonthePSLProceduresicon.OntheSearchlinetoolbar,clickthefarrightbutton(with2circlesandadownarrow).C.d.e.SelectGroupSearchfromthedropdownmenu.IntheSearchlinetype"EP"(wherethe"XX"is).ClickSearchorhitEnter.3.f.EPIPlistisnowdisplayed(notinanyparticularorder).9.Toprintthelist-ClickFile-SelectPrintfromthedropdownmenu-SelectViewOptionsinthedialogueboxClickOKTelecopytheECLog,completednotificationformsandchecklists,andanyotherpertinentinformationtotheEOF.
REVISIONNO.:PROCEDURENo.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:57of90ATTACHMENT6TSCADMINISTRATIVESTAFFCHECKLIST(Page2of3)B.FACILITYOPERATIONNOTEInformationshouldbeupdatedevery15-30minutesandnotlongerthan60minutes.2.Synchronizethefacilityclock(s)withERDADS.IncaseofERDADSfailure,synchronizewiththeaffectedControlRoom.Stepstooccurcontinuallywhilethefacilityisinoperation:80C.d.ObtainthefollowingERDADSdatasheets(printouts)fromtheERDADSOperator:1.SafetyFunctionsEquipmentStatus(SF1/2).2.RadioactiveGaseousSourceTerms(RG1/2).UpdatestatusboardswithnewERDADSdata.Requestthesound-poweredphonetalkertoobtainanyinformation/datanotprovidedbytheERDADSprintouts.Verifyalldatahasbeenaccuratelytransferredtothestatusboard.e.Updatethesequenceofeventsboardfollowingeachfacilitybriefingandasneeded.Providerelevantinformationconcerningitemssuchas:1.Changeinclassification.2.Significantchangeinplantcondition.3.Statusofplantsystem(s)ofconcern.4.Injuredpersonnelstatus.5.Otheritemsofrelevantinterest.g.UpdatedoseassessmentandfieldmonitoringdataasinformationisprovidedbyChemistryandHP,respectively.Makecorrections,whenidentified,bycirclingthecorrecteddata.
REVISIONNO.:PROCEDURENo.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:58of90B.C.ATTACHMENT6TSCADMINISTRATIVESTAFFCHECKLIST(Page3of3)2.(continued)h.Whenallstatusboardcolumns/blanksarefilled,erasethefirsttwocolumns/blanks,enternewdatawithadifferentcoloredmarkerleavingaspacebetweenthenewandtheolddata.i.ProvideanyincomingtelecopymaterialstotheTSCSupervisororasdesignatedonthecoverpage.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.2.3.Statusboardshavebeencleanedandreturnedtopreactivationcondition.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheTSCSupervisor.Returnedpositionnotebooktostoragecabinet.ENDOFATTACHMENT6 REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT7TSCCOORDINATORWITHOSCCHECKLIST(Page1of2)PAGE:59of90NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofseuence.A.FACILITYACTIVATIONRefertoSection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.FACILITYOPERATIONEstablishcontactwiththeOSCCoordinatorwiththeTSC(intheOSC).INITIAL2.Stepstooccurcontinuallywhilethefacilityisinoperation:Ensureallrequestsforre-entryactivitiesaredocumentedonAttachment7A,Re-entryWorksheet.Ensureallre-entryrequestshavebeenapprovedandprioritizedbytheEC.C.d.e.TrackallrequestsforRe-entryTeamsusingAttachment78,Re-entryLog.Communicatere-entryrequeststotheOSCCoordinatorwiththeTSCperAttachment7B,Re-entryLog.UpdatetheOSCStatusBoardwithRe-entryTeaminformation.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT7TSCCOORDINATORWITHOSCCHECKLISTPAGE:60of90(Page2of2)C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.ClosedoutallRe-entryTeamsenteredintheRe-entryTeamLogandthestatusboard.2.Statusboardhasbeencleanedandreturnedtopreactivationcondition.3.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheTSCSupervisor.4.Returnedpositionnotebooktostoragecabinet.ENDOFATTACHMENT7 REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHE'ECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT7ARE-ENTRYWORKSHEET(Page1of7)DATASHEET1REQUESTDESCRIPTION(Page1of1)PAGE:61of90NOTEThisworksheetisusedforthefollowing:1.Requestingin-plant/fieldresponseactivitiespriortotherestrictionsimposedbylocaland/orsiteevacuation.2.RequestingRe-entryTeamdispatchfromtheOperationalSupportCenter(OSC).3.RequestingengineeringsupportfromtheEmergencyOperationsFacility(EOF).4.RequestingSAMGdirectivestotheControlRoom(s)(CR(s)).Attacharoriatedatasheetstoetherforeachreuest.Step1.DESCRIBEthenatureoftheproblem/concern/request:Originatedby:(Attachadditionalpagesifrequired)Date/Time://ForwardtoPSTLeaderStep2.Istherequestcomplex(i.e.,notroutineorcoveredbyexistingplantprocedure(s))?CIYes,GotoDataSheet20No,GotoDataSheet3Signature:PSTLeaderDate/Time://ENDOFDATASHEET1 REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:62of90ATTACHMENT7ARE-ENTRYWORKSHEET(Page2of7)DATASHEET2PSTACTIONS(Page1of1)Step1~PSTLeaderASSIGNaPSTmembertofilloutthefollowingassessment/review(initialanddateentry):(Attachadditionalpagesifrequired)NOTE50.59screeningisrequiredforanyalterationsofsystems,structuresorcomponents.ActionsthatareoutsideofdesignbasisshallrequireimlementationofADM-17.09,Invokin50.54x.Step2.A.PSTPROVIDErecommendation/responsebelow(initialanddateentry):orB.IfEOFassistanceisneeded,ThencompleteDataSheet4andattach.(Attachadditionalpagesifrequired)Step3.A.Ifrecommendation/responseactiondetailedinStep2aboveisNOTroutineorcoveredbyexistingplantprocedure(s),ThenPERFORMa50.59ScreeninginaccordancewithADM-17.11,10CFR50.59Screening(ifnotperformedbytheEOF).50.5900YNB.IftheactionsareSAMGrelated,ThencompleteDataSheet5andattach.SAMG00YNSignature:PSTLeaderENDOFDATASHEET2Date/Time://
REVISIONNO.:PROCEDURENo.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:63of90ATTACHMENT7ARE-ENTRYWORKSHEET(Page3of7)DATASHEET3ECREVIEWANDAPPROVAL(Page1of3)Step1.ReviewofproposedactionA.Iftheaction/activityisroutineorcoveredbyexistingplantprocedure(s),ThengotoStep2.B.Considerthefollowingquestionsinthereviewfortaskapproval(ECinitialsrequired).DotheseactionsaffectthemarginofnuclearsafetyoftheunaffectedUnitthathasNOTbeenaddressed?INITIAL2.3.Aretheinstructionsclearandeasytounderstand?Areallreferencedcomponentsandsystemsproperlyidentifiedandlabeled?4.Haveappropriateengineeringreviewsbeenperformedtoavoidunintentionaloperationofsystemsoutsidedesigncharacteristics?5.Dosteps,thathaveoperatingparametersspecified,containoperatingbands?Step2.Approval0Approveaswritten0Approvewiththefollowingcorrections/changes:
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT7ARE-ENTRYWORKSHEET(Page4of7)DATASHEET3ECREVIEWANDAPPROVAL(Page2of3)PAGE:64of90INITIALCAUTIONPrioritiesaresetbasedontheurgencyofthetaskandbyconsideringresourcesavailable(NOTeverythingisorcanbepriority0),evaluatethoughtfully.0=Dispatchteaminlessthan5minutes(fire,injuryorcertainoperatoractions)1=Dispatchteaminlessthan15minutes(EmergencyCoordinatortoppriority)2=Disatchteaminlessthan30minutesroutinere-entriesStep3.Priority(circleone):012Step4.Signature:EmergencyCoordinatorDate/Time://Step5.FORWARDtheAttachment7A(appropriatedatasheets)totheapplicablecommunicator.A.IfthetaskisspecificallyfortheOSC,ThentheTSCCoordinatorwithOSCshallperformthefollowing:1.ASSIGNataskdescription:2.COMPLETERe-entryLogentry.3.COMMUNICATEthetasktotheOSC(recordtimecallcompleted:)OR REVISIONNO.:PROCEDURENO.:EPIP-04Step5.(continued)PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT7ARE-ENTRYWORKSHEET(Page5of7)DATASHEET3ECREVIEWANDAPPROVAL(Page3of3)PAGE:65of90INITIALB.IfthetaskisspecificallyforOperations,ThentheTSCOPSCoordinatorshallPERFORMthefollowing:COMMUNICATEthetaskinstructionstotherequiredControlRoom(s).2.IfOSCconcurrentre-entryactionsarerequired,ThenORIGINATEanewRe-entryWorksheetformforthispurpose.Step6.RETURNtheformtotheoriginatornamedinDataSheet1.ENDOFDATASHEET3 REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT7ARE-ENTRYWORKSHEET(Page6of7)DATASHEET4EOFASSISTANCE(Page1of1)PAGE:66of90INITIALStep1.IfEOFassistanceisdeterminedtoberequired,ThenthePSTLeader(ordesignee)shallperformthefollowing:A.SENDDataSheets1and2totheEOF(verbaland/ortelecopy).Step2.NOTE50.59screeningisrequiredforanyalterationsofsystems,structuresorcomponents.ScreeningsaretobeperformedinaccordancewithADM-17.11,10CFR50.59Screenin.A.EOFPROVIDErecommendation/responsebelow:(Attachadditionalpages,ifrequired)Step3.Ifrecommendation/responseactiondetailedinStep2aboveisNOTroutineorcoveredbyexistingplantprocedures,ThenPERFORMa50.59screening.Signature:Emerg.Tech.Mgr./EOFProj.Eng.Date/Time://Step4.EmergencyTechnicalManager(ordesignee)RETURNEOFrecommendation/responsetothePSTLeaderforreviewandappropriateaction.ENDOFDATASHEET4 REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT7ARE-ENTRYWORKSHEET(Page7of7)DATASHEET5SANG(Page1of1)PAGE:67of90INITIALStep1.IftheactionsareSAMGrelated,ThenthePSTLeader(ordesignee)shall:A.ASSIGNaSAMGtrackingnumber-SAMGSequenceNumber:SAMG-B.POSTthetaskonthePSTSAMGWhiteEraseBoard.NOTEDuringsevereaccidentevents,where10CFR50.54(x)hasbeeninvokedononeUnitattheentryoftheSAMGs,alterationsaffectingtheotherUnit'shardware,structures,systemsorcomponents,outsidedesignbasis,shallrequireseparate50.54(x)invocationsinaccordancewithADM-17.09,Invokin10CFR50.54x.Step2.CONSULTtheTSCOPSCoordinatorfor10CFR50.54(x)SROevaluation.Step3.Ifimplementationof10CFR50.54(x)isrequired,ThenIMPLEMENTADM-17.09.ENDOFDATASHEET5ENDOFATTACHMENT7A REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:68of90ATTACHMENT7BRE-ENTRYLOG(Page1of1)RE-ENTRYTASKREQUESTCompletethissectionwithinformationfromtheRe-entryWorksheetandtransfertoOSC.RE-ENTRYTEAMASSIGNMENTOSCCoordinatorwithTSCshouldprovidethisinformationoncecompletedbytheOSCSuervisor.A.TaskDescription:B.*PriorityC.TimeD.Reasonforrequest:G.TeamNo.:H.Title:I.Re-entrySupv.:J.Timeout:L.Comments:K.Timein:E.Infocontact:F.Phone:A.TaskDescription:B.PriorityD.Reasonforrequest:E.Infocontact:F.Phone:A.TaskDescription:B.*PriorityD.Reasonforrequest:E.Infocontact:F.Phone:C.TimeC.TimeG.TeamNo.:H.Title:I.Re-entrySupv.:J.Timeout:L.Comments:G.TeamNo.:H.Title:I.Re-entrySupv.:J.Timeout:L.Comments:K.Timein:K.Timein:A.TaskDescription:B.*PriorityC.TimeD.Reasonforrequest:E.Infocontact:F.Phone:G.TeamNo.:H.Title:I.Re-entrySupv.:J.Timeout:L.Comments:K.Timein:A.TaskDescription:B.'PriorityD.Reasonforrequest:E.Infocontact:F.Phone:C.TimeG.TeamNo.:H.Title:I.Re-entrySupv.:J.Timeout:L.Comments:K.Timein:*0=Dispatchinlessthan5minutes(e.g.,fire,injury,orcertainOperatoractions)1=Dispatchinlessthan15minutes(e.g.,EmergencyCoordinatortoppriority)2=Dispatchinlessthan30minutes(e.g.,routinere-entries)ENDOFATTACHMENT7B REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:69of90ATTACHMENT8TSCOPSCOORDINATORCHECKLIST(Page1of4)NOTE1.Thispositionisfilledbytwopersons,onelocatedintheaffectedControlRoom,theotherintheTSC.ThepositionintheControlRoomisalsoknownastheNPSCommunicator.2.Whennecessaryorappropriate,stepsofthischecklistmaybeerformedoutofseuence.A.FACILITYACTIVATIONINITIALNOTEThefirstpersontoarriveattheTSCshouldreporttotheaffectedControlRoomtorelievetheDuCallSuervisor.B.1.Fillingpositionin:2.(TSCpositiononly)RefertoSection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.FACILITYOPERATION2.Establishcommunicationswithcounterpart.IntheTSC,establishtheOPSConferenceBridgeasfollows:b.Obtaincontactphonenumbersfor:OPSCoordinatorintheControlRoom2.OSCOPSRe-entrySupervisor3.ProblemSolvingTeam4.OtherparticipantCalltheOPSCoordinator1.State:"stayontheline"2.Depresstheconferencebutton REVISIONNO.:PROCEDURENo.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:70of90B.2.(continued)ATTACHMENT8TSCOPSCOORDINATORCHECKLIST(Page2of4)INITIAL3.4,c.CalltheOSCOPSRe-entrySupervisor1~State:"stayontheline"2.Depresstheconferencebuttond.CalltheProblemSolvingTeam1.State:"presshandsfree/mutebutton"2.Depresstheconferencebuttone.Callanyotherparticipant1.State:"stayontheline"2.Depresstheconferencebuttonf.Hailallpartiestoverifybridgesuccessfullyestablished.InitiatetheOPSLogbook.(TSConly)Stepstooccurcontinuallywhilethefacilityisinoperation:TSCProvideexpertiseinplantoperationstotheEC.MaintaincommunicationflowbetweentheTSCandtheaffectedControlRoomconcerningstatusofoperations.C.MaintainOPSLogbook.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:71of90B.4.(continued)ATTACHMENT8TSCOPSCOORDINATORCHECKLIST(Page3of4)INITIALd.SevereAccidentManagementGuidelines(SAMG)actionsPerformevaluationsinaccordancewithADM-17.09,Invoking10CFR50.54(x),asneeded.2.Review/approveactionsasoutlinedinAttachment7A,Re-entryWorksheet.3.CommunicateSAMGactionstotheaffectedControlRoom(s).ControlRoom80b.C.d.ProvidecommunicationsassistancetotheNPS.MonitorprocedureuseandkeeptheTSCinformed.Investigatequestions/concernsasrequestedbytheTSC.Updatetheunaffectedunit'sControlRoomwithemergencystatus.e.GatherSevereAccidentManagementGuidelines(SAMG)instructions/informationfromtheTSCOPSCoordinator.1.IftheTSCisunabletotelecopy,ThenuseAttachment7A,Re-entryWorksheettorecordSAMGinstructions/information.CommunicateSAMGactionstotheNPS.ProvidefeedbacktotheTSCOPSCoordinatorregardingSAMGactions.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:72of90ATTACHMENT8TSCOPSCOORDINATORCHECKLIST(Page4of4)C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.2.3.4.Phoneconnectionterminated.ClosedouttheOPSLogbook.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheTSCSupervisor.Returnedpositionnotebooktostoragecabinet.ENDOFATTACHMENT8 REVISIONNO.:PROCEDURENo.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT9TSCREACTORENGINEERCHECKLIST(Page1of3)PAGE:73of90A.B.NOTEWhennecessaryorappropriate,stepsinthischecklistmaybeperformedoutofseuence.FACILITYACTIVATION1.RefertoSection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.FACILITYOPERATIONEstablishtheERDADSlinkwiththeNRCEmergencyResponseDataSystem(ERDS)(useAttachment9A,InitiatingandTerminatingtheERDSLink).INITIAL REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:74of90B.(continued)ATTACHMENT9TSCREACTORENGINEERCHECKLIST(Page2of3)INITIAL2.Stepstooccurcontinuallywhilethefacilityisinoperation:CAUTIONBeawareofthefollowingconditions.TheseEmergencyActionLevels(EALs)areassociatedwithInitiatingConditions(ICs)usedintheclassificationofemergencies(EPIP-01,ClassificationofEmergencies).TheEmergencyCoordinatorneedstoknowifanyoftheseconditionsexist.1.DoseEquivalentIodine(DEQ)l-131activitygreaterthan275pCI/ml.2.CHHRMreadingsgreaterthan7.3E+03R/hrORgreaterthan1.46E+05R/hr.3.PostLOCAMonitorreadingsgreaterthan100mR/hrORgreaterthan1000mR/hr.4.StepincreaseinradiationmonitorreadingsinthePlantVentand/orFuelHandlingBuilding.5.Lossofsubcoolmarginresultinginsaturatedconditions.6.HighestCoreExitThermocouple(CET)percorequadrantindicatesgreaterthan10'Fsuperheator700'F.7.Damagetomorethanoneirradiatedfuelassembly.8.UncoveringofoneormoreirradiatedfuelassembliesintheSpentFuelPool.a.Monitorcriticalplantparametersforindicationsofcorestatus.b.C.AssistNuclearFuelspersonnelintheEOFintheassessmentofcoredamageinaccordancewithEPIP-11,CoreDamageAssessment.AssistinSevereAccidentManagementGuidelines(SAMG)activitiesasaSAMGEvaluator.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:75of90ATTACHMENT9TSCREACTORENGINEERCHECKLIST(Page3of3)C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.2.3.Coredamageassessmentactivitiesterminated.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheTSCSupervisor.Returnedpositionnotebooktostoragecabinet.ENDOFATTACHMENT9 REVISIONNo.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:76of90ATTACHMENT9AINITIATINGANDTERMINATINGTHEERDSLINK(Page1of2)ThisattachmentprovidestheinstructionsforinitiatingandterminatingthecommunicationslinkbetweentheSt.LucieEmergencyResponseDataAcquisitionandDisplaySystem(ERDADS)andtheNRCEmergencyResponseDataSystem(ERDS).ThiscommunicationslinkmustbeactivatednotlaterthanonehourafterdeclaringanemergencyclassofALERTorhigher.IfcommunicationscannotbeestablishedthentheacceptedmethodofdatatransmissiontotheNRCwillbethroughtheEmergencyNotificationSystem(ENS).INITIATINGtheERDScommunicationlink:AtanyTSCERDADSterminalclearthedisplayscreenbydepressingtheCLEARkey.LogontoERDADSbytypinginPSW&XXXXXXXX(theXsstandforthepasswordissuedtoOperationsSupportEngineering).ThendepresstheEXECkey.ClearthescreenwiththeCLEARkeyandselectthedesiredSt.LucieUnitbytypingPUPUNITX(theXwillbeeithera1or2dependingontheunit).ThendepresstheEXECkey.4.5.6.7.ClearthescreenbydepressingtheCLEARkeyandtypeinERDanddepresstheDSPLYkey.ThiswilldisplaytheERDSlinkcontrolpictureontheterminal.DepresstheTAB+keystoplacethecursorontheINITIATEactionbarandthendepresstheENTERkey.ThedepressingoftheENTERkeywillinitiatethecommunicationslinktotheNRCERDS.AfterthecommunicationlinkwiththeNRCERDShasbeenestablishedcleartheterminalscreenbydepressingtheCLEARkeyandlogoffbytypinginPSW0anddepressingtheEXECkey.Theloggingoffoftheterminal'sscreenwillallowthatterminaltobeusedinobtaininginformationforTSCactivitieswithoutaffectingthecommunicationlinkwiththeNRCERDS.PeriodicallycheckthestatusoftheERDSlinkbytypinginHLX(theXwillbea2forUnit1or3forUnit2)anddepresstheDSPLYkey.
REVISIONNO.:PROCEDURENo.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT9AINITIATINGANDTERMINATINGTHEERDSLINK(Page2of2)PAGE:77of90NOTE~IftheblinkingmessageNOTIFYTHENRCappearsaftertheCURRENTSTATUSthenthecommunicationslinkhasbeenlostandareconnectionisnecessarywhentheNRCrequestsitthroughtheestablishedvoiceconnectionintheTSC.Ifthishappensthenitwillbenecessarytoreinitiatethecommunicationslinkbeginningwithstep1.~GenerallytheERDSlinkwillbeterminatedbytheNRC.ThefollowingstesaretobeusedifthelinkneedstobeterminatedfromtheTSC.TERMINATINGtheERDScommunicationlink:AtanyTSCERDADSterminalclearthedisplayscreenbydepressingtheCLEARkey.2.3.4.5.6.tgtEgghgghytygtgtPgtgggXXXXXXXXtthXtdtthpasswordissuedtoOperationsSupportEngineering).ThendepresstheEXECkey.ClearthescreenwiththeCLEARkeyandselectthedesiredSt.LucieUnitbytypingPUPUNITX(theXwillbeeithera1or2dependingontheunit).ThendepresstheEXECkey.ClearthescreenbydepressingtheCLEARkeyandtypeinERDanddepresstheDSPLYkey.ThiswilldisplaytheERDSlinkcontrolpictureontheterminal.DepresstheTAB-keystoplacethecursorontheTERMINATEactionbarandthendepresstheENTERkey.ThedepressingoftheENTERkeywillterminatethecommunicationslinktotheNRCERDS.AfterthecommunicationlinkwiththeNRCERDShasbeenterminatedcleartheterminalscreenbydepressingtheCLEARkeyandlogoffbytypinginPSW0anddepressingtheEXECkey.ENDOFATTACHMENT9A REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT10TSCCHEMISTRYSUPERVISORCHECKLIST(Page1of3)PAGE:78of90NOTEWhennecessaryorappropriate,stepsinthischecklistmaybeperformedoutofseuence.A.B.FACILITYACTIVATION1.RefertoSection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.FACILITYOPERATION1.InitiatetheChemistryLogbook.2.Stepstooccurcontinuallywhilethefacilityisinoperation:INITIALNOTEDoseassessmentshallbeaprimaryresponsibilityoftheEOFonceitbecomesoerational.8$b.C.d.e.Supervisedoseassessmentactivities.Reviewalldoseprojectionprintouts.AdvisetheECofdoseprojectionresults.AssisttheECinevaluatingoff-sitedoseestimatesforPARs.AssisttheTSCECAssist/Logkeeper/ECindeterminingthe"Off-siteReleaseSignificanceCategory"ascalledforontheStateNotificationForm,asnecessary.ProvidetechnicalsupporttotheOSCChemistrySupervisor.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:79of90ATTACHMENT10TSCCHEMISTRYSUPERVISORCHECKLIST(Page2of3)B.2.(continued)CAUTIONBeawareofthefollowingconditions.TheseEmergencyActionLevels(EALs)areassociatedwithInitiatingConditions(ICs)usedintheclassificationofemergencies(EPIP-01,ClassificationofEmergencies).TheEmergencyCoordinatorneedstoknowifanyoftheseconditionsexist.1.DoseEquivalentIodine(DEQ)I-131activitygreaterthan275pCi/ml.2.Resultofanalysisofagaseousorliquidreleaseisgreaterthanten(10)timestheODCMlimit.3.CHHRMreadingsgreaterthan7.3E+03R/hrORgreaterthan1.46E+05R/hr.4.PostLOCAMonitorreadingsgreaterthan100mR/hrORgreaterthan1000mR/hr.5.StepincreaseinradiationmonitorreadingsinthePlantVentand/orFuelHandlingBuilding.6.Off-sitedosecalculationworksheetvaluesatone(1)mileinexcessof50mrem/hr(totaldose-TEDE)or250mrem/hr(thyroiddose-CDE)foronehalf(1/2)hourOR500mrem/hr(totaldose-TEDE)or2500mrem/hr(thyroiddose-CDE)fortwo(2)minutes.7.Off-sitedosecalculationworksheetvaluesindicatesiteboundary(one(1)mile)exposurelevelshavebeenexceededasindicatedbyanyofthefollowing:a.1000mrem/hr(totaldoserate)b.1000mrem(totaldose-TEDE)c.5000mrem/hr(thyroiddoserate)d.5000mremthroiddose-CDEg.AdvisetheEConplantchemistryrelatedmatters.h.Maintainchronologicallogofactivities.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT10TSCCHEMISTRYSUPERVISORCHECKLIST(Page3of3)PAGE:80of90B.2.(continued)i.Reviewandverifyradiologicalandprotectiveactioninformationenteredonstatusboards.C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.1.Doseassessmentactivitiesterminated.2.3.a.ClosedouttheChemistryLogbook.Providedallpaperwork(notboundinthepositionnotebook)totheTSCSupervisor.Returnedpositionnotebooktostoragecabinet.ENDOFATTACHMENT10 REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT11TSCDOSEASSESSORCHECKLIST(Page1of2)PAGE:81of90NOTEWhennecessaryorappropriate,stepsinthischecklistmaybeperformedoutofseuence.A.FACILITYACTIVATION1.RefertoSection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.B.FACILITYOPERATIONINITIALNOTE1.InitialoperatinginstructionsforuseoftheClassAModelareprovidedinEPIP-09,Off-siteDoseCalculations.2.IfthecomputerizedClassAModelisnotavailable,doseprojectionsshallbeerformedinaccordancewithEPIP-09.1.EnsureallpreviousdosecalculationpaperworkissenttotheEOF.2.EstablishcommunicationlinkwiththeEOFDoseAssessor.3.4.CompleteClassAModelQCCheck.Stepstooccurcontinuallywhilethefacilityisinoperation:8$b.C.ObtaininputdatafortheClassAModelfromtheERDADSOperator(RG1/2Screen).ReportdoseprojectionresultstotheTSCChemistrySupervisor.CoordinatedoseassessmentwiththeEOFunlessdirectedotherwisebytheTSCChemistrySupervisor.
REVISIONNo.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:82of90B.4.(continued)ATTACHMENT11TSCDOSEASSESSORCHECKLIST(Page2of2)INITIALC.d.ProvidestatusboardupdateinformationtotheTSCAdministrativeStaff(useAttachment11AandAttachment11B).1.Usingcarbonpaper,makeacopyasdataisenteredintotheformineitherAttachment11Aor11B.Retaintheoriginal,providethecopytotheTSCAdministrativeStafftoupdatethestatusboards.FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.3.4.5.6.Doseprojectionactivitiesterminated.EOFcommunicationslinkedterminated.Alldocuments,equipmentandsuppliesreturnedtopreactivationconditionand/orlocation.Allpaperworkcollected.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheTSCChemistrySupervisor.Returnedpositionnotebooktostoragecabinet.ENDOFATTACHMENT11 REVISIONNO.:PROCEDURENo.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:83of90ATTACHMENT11AOFF-SITERADIOLOGICALASSESSMENT(Page1of1)OFFSITEDOSERADIOLOGICALASSESSMENTSTATUSANDTRENDSPARAMETERDa¹ofMonthTimeofDaDownwindSectorsUnit2400HihestDownwindSectorDoseRatesDoseRate1mile2miles5miles10milesmRem/hrmRem/hrmRem/hrmRem/hrTEDECDETEDECDETEDECDETEDECDEWindDirectionat10meterelevDownwindSectorWindSpeedat10meterelev60meter-10meterdeltaTStabilitClass10meterTemeratureDegreesmphDegFDeFNobleGasRelRateiodineRelRateNobleGasTotalCiiodineTotalCiContainHiRaneCi/secCi/secCiCiR/hrVentECCSAECCSBMainSteamAMainSteamBCi/secCi/secCi/secmR/hrTEDE=TotalDoseCDE=ThyroidDoseENDOFATTACHMENT11A REVISIONNO.:PROCEDURENO.:EPIP-04REASON:ISSUEDBY:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT11BPROTECTIVEACTIONRECOMMENDATIONS(Page1of1)PROTECTIVEACTIONRECOMMENDATIONSDATE/TIMES=SHELTERE=EVACUATEPAGE:84of90ASECTORNNE0-2Miles2-5Miles5-10MilesENEGESESESSESSWSWSWQNWNWNNWADDITIONALCOMMENTS:ENDOFATTACHMENT11B REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT12TSCPROBLEMSOLVINGTEAMCHECKLIST(Page1of2)PAGE:85of90NOTE1.ThischecklistappliestothefollowingProblemSolvingTeam(PST)positions:TSCPSTLeader(Engineering)TSCElecRep-PSTTSCl&CRep-PSTTSCMechRep-PST(3)TSCSRORep-PST2.Whennecessaryorappropriate,stepsofthischecklistmaybeerformedoutofseuence.A.FACILITYACTIVATION1.RefertoSection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.B.FACILITYOPERATIONINITIALNOTE1.RefertotheDocumentControlIndexforalistingofTechManualsavailableintheTSC.2.ThecomputerprovidesaLANconnectionandaccesstotheTotalEuimentDatabaseTEDB.Stepstooccurcontinuallywhilethefacilityisinoperation:arProblemSolvingTeamLeader1~MaintaincommandandcontrolofallPSTactivities.ThefromprovidedinAttachment12A,PSTActivitiesListmaybeusedbythePSTtotrackandcommunicatethestatusofPSTactivities.2.EnsureallPSTmembersareawareofandunderstandthestatusofequipment.3.MaintainhighlevelofinquiryandinvestigationbyallPSTmembers.4.TrackprogressofallRe-entryWorksheets(Attachment7A)giventoorinitiatedbythePST.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:86of90ATTACHMENT12TSCPROBLEMSOLVINGTEAMCHECKLIST(Page2of2)1.a.(continued)5.Encouragedevelopmentofmultiplesuccesspaths.6.ReviewallRe-entryWorksheets(Attachment7A).b.ProblemSolvingTeamMember1~ParticipateasamemberoftheProblemSolvingTeambyprovidingtechnicalsupportinyourareaofexpertise.2.Evaluatesystemandequipmentfailures.3.Proposemitigativeandcorrectiveaction(s)aspromptlyaspossible.4.DocumentrecommendationsonaformsimilartoAttachment7A,Re-entryWorksheet.5.ServeasaSevereAccidentManagementGuidelines(SAMG)Evaluator.6.ProvideallrecommendationstotheEC.INITIALFACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.Returnedalldocuments,equipmentandsuppliestopreactivationconditionand/orlocation.2.3.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheTSCSupervisor.Returnedpositionnotebooktostoragecabinet.ENDOFATTACHMENT12 REVISIONNOPROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT12APSTACTIVITIESLIST(Page1of1)PAGE:87of90ItemProblemDescritionProbableCausePSTRecommendationStatusENDOFATTACHMENT12A REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT13TSCSECURITYSUPERVISORCHECKLIST(Page1of3)PAGE:88of90NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofseuence.A.B.FACILITYACTIVATION1.RefertoSection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.VerifythattheEnergyEncounterhasbeennotifiedoftheemergency.(consulttheERDSection3.6,othercompanynumbers,forthephonenumber)FACILITYOPERATION1~EstablishaccesscontrolfortheTSC.INITIAL2.3.a.5.ContacttheControlRoomsandrequesta~cornlated"OperationsDepartmentAccountabilityAid"beforwardedtotheTSC.Initiatefacilityaccountabilitybyrequestinga~cornletedcopyofAttachment3A,TSCEROShiftStaffingandAccountabilityRosterfromtheTSCSupervisor.TelecopythecompletedAttachment3A,TSCEROShiftStaffingandAccountabilityRoster,andthe"OperationsDepartmentAccountabilityAid"formstoSecurity.ContacttheEOFEmergencySecurityManager(ESM).a.Establishresponsibility/protocolfornotificationofoff-siteauthoritiesregardingthestatusofsiteevacuation.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:89of90B.ATTACHMENT13TSCSECURITYSUPERVISORCHECKLIST(Page2of3)(continued)6.UpondeclarationofaSiteAreaEmergency.INITIALa.Startaccountabilityat:b.Startsweepsat:1.Off-siteworkareas.2.WestfortyandFitnessCenter.3.OwnerControlledArea.a.Beachside.b.Riverside.4.On-siteandRadiationControlledArea.5.MarineResearchCenter.7.c.Accountabilitycompletedatd.SweepscompletedatStepstooccurcontinuallywhilethefacilityisinoperation:CAUTIONEnsuretheECisawareofanyactionsrequiredbytheSecurityPlane,alertoremerencdeclaration,susensionofsafeuards,etc..a.AdvisetheEConSecurityrelatedmanners.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:90of90B.ATTACHMENT13TSCSECURITYSUPERVISORCHECKLIST(Page3of3)7.(continued)b.InconjunctionwiththeESM,provideliaisonfunctionbetweenlocallawenforcementandrescueagenciesandFPLforissuessuchas:INITIALC.Bombthreatsoractsofterrorism.2.Memberofthepublicormediaarrivingatthesite.3.Siteegressandingress.4.Fireorrescue/medicalresponse.c.CoordinatesafeguardssuspensionwiththeESMandEC.d.Maintainsiteaccountabilityofallpersonnelthroughouttheemergency.e.FollowSecurityProcedures.FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.1.Closedoutwiththelocallawenforcementagencies,asneeded.2.3.4.5.ClosedoutSecurityLogbook.Allpaperworkcollected.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheTSCSupervisor.Returnedpositionnotebooktothestoragecabinet.ENDOFATTACHMENT13 Title:FPLST.LUCIEPLANTEMERGENCYPLANIMPLEMENTINGPROCEDURESAFETYRELATEDProcedureNo.EPIP-05CurrentRev.No.5EffectiveDate:08/10/00ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERResponsibleDepartment:RevisionSummaryEMERGENCYPLANNINGRevision5-EliminatedOSCparamedicposition,revisedre-entryguidelinesandmadeeditorialandadministrativechanges.(G.Varnes,08/08/00)Revision4-ClarifiedroleofOPSRe-entrySupervisorperPM99-04-122.AddedguidelinesforOSCcommandandcontrolassistanceperPM99-04-143.ProvidedinstructionsforemergencyaccesstorestrictedareasperPM99-09-079.RevisedtheminimumstaffpositioninChemistrytotheOSCChemistry.Clarifiedfacilitysign-inandaccountabilityinstructions.Reinforcedinstructionsfordevelopmentofacontingencyteam.Madeeditorialchanges.(RickWalker,10/05/99)Revision3-AddedOSCinformationservicesreppositionandresponsibilitiestoprocedureandaddededitorialchanges.(J.R.Walker,3/2/99)RevisionFRGReviewDate12/15/97RevisionFRGReviewDate08/08/00ApprovedByJ.ScarolaPlantGeneralManagerApprovedByR.G.WestPlantGeneralManagerN/ADesignatedApproverN/ADesignatedApprover(MinorCorrection)ApprovalDate12/15/97ApprovalDate08/08/00SOPSDATEDOCTPROCEDUREDOCNEPIP-05sYsCOMPCOMPLETEDITM5PSLPROCEDUREPIMDUCnoN CIII5IIIJ<)vIjj'A REVISIONNo.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTTABLEOFCONTENTSPAGE:2of55SECTIONPAGE1.0PURPOSE~~~~~~~~0~0~~~~~~~0~
42.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTS.............................63.0RESPONSIBILITIES3.1OSCSupervisor...............3.2OSCCoordinatorwithTSC~....~.3.3OSCRe-entrySupervisor........3.4OSCDepartmentalRepresentative.~~~~~~~~~~07~~~~~~~~~~~~~~~~7~~~~~~~~~~~~~~~~~~~~~8~~~~~~~~~'~~~~~~~~~~8~94.0DEFINITIONS..~...~..~.~~~...~~~..~..~....~...~.~....95.0INSTRUCTIONS~...ATTACHMENTSATTACHMENT1OSCEmergencyResponseOrganizationandShiftStaffing.........~........~~.~..~.~........13ATTACHMENT2OSCSupervisorChecklist.....~....~~:........~14ATTACHMENT2AOSCEROShiftStaffingandAccountabilityRoster...~19ATTACHMENT2BOSCMinimumStaffing.....~~..~..~..~.~~.....23ATTACHMENT2CRe-entryGuidelines..........................24ATTACHMENT2DBriefingGuidelines........~..~~~~~~~~~27ATTACHMENT2EGuidelinesforRelocationoftheOSCATTACHMENT2FOSCFacilityBriefings....~....~.~..~....ATTACHMENT3OSCCoordinatorwithTSCChecklist........28~..~~3031ATTACHMENT3ARe-entryLog......~~~~~~~~~~33 REVISIONNO.:PROCEDURENo.:EPIP-05SECTIONPROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTTABLEOFCONTENTS(continued)PAGE:3of55PAGEATTACHMENT4OSCAdministrativeTech/LogkeeperChecklist.......34ATTACHMENT4ALogkeepingand-StatusBoards~~~~~~~~~~~~36ATTACHMENT5OSCRe-entrySupervisorChecklist..~.....~.~.~..37ATlACHMENT5ARe-entryTeamForm.........................41ATlACHMENT5BRe-entryTeamGuidelines~~~~~~~~~~~~43ATTACHMENT6OSCRe-entryForemanChecklist...~....~.~~.ATTACHMENT7OSCDepartmentalRepsChecklist.~~......~~....46ATTACHMENT7ARoom2200Guidelines.ATTACHMENT7BRoom2200SetUpATTACHMENT8OSCSecurityChecklist~~~~~~~~~~~~~~~~~~o49~~~~~~~~~~~~~~~~~~~~~52~~~~~~~~~~~~~~~53 REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERPAGE:4of55EPIP-051.0PURPOSEST.LUCIEPLANT1.1DiscussionThisprocedureprovidesinstructionsforactivationandoperationoftheOperationalSupportCenter.ThisprocedurealsoprovidesinstructionsfortheselectionanddeploymentofRe-entryTeams.1.2LocationandDescriptionTheOSCislocatedonthesecondflooroftheSouthServiceBuildinginconferenceroom2200andadjoiningroom2300.Amplespaceisavailablefortheassemblyofauxiliaryoperators,HeathPhysicstechnicians,Maintenancepersonnel,andotherpersonnelneededforemergencyresponse.Duetopotentialhabitabilityconcerns,alternatelocationscapableofsupportingOSCoperationshavebeenidentifiedasfollows:1.NorthServiceBuilding,conferenceareaormaintenanceshops2.BlowdownBuilding3.UnaffectedReactorAuxiliaryBuilding(RAB)1.3OSCFunctions1.MandatoryFunctionsA.ProvidearesourcepoolofpersonneltoassisttheControlRoomandTSCinaccidentassessmentandmitigation.B.RespondtorequestsforRe-entryTeams.C.MaintainradiologicalexposurecontrolsinaccordancewiththeHP-200seriesprocedures.2.AdditionalFunctionsA.ProvidetheinterfacewiththeOff-siteAssemblyArea.B.Serveasaccesscontrolpointfollowingsiteevacuation.
REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERPAGE:5of55EPIP-051.0PURPOSE(continued)1.4MinimumStaffingST.LUCIEPLANTThefollowingisthelistoftheminimumpositionsneededforOSCoperation:~OSCSupervisor~OSCChemist~OSCHPTechnician(12)~OSCElectrician(2)~OSCMechanic(2)~OSCl8CSpecialistg,1.5ActivationActivationoftheOSCistheresponsibilityoftheEmergencyCoordinator(EC)andisrequiredforanAlertorhigherdeclaredemergency.ArrangementshavebeenmadetostafftheOSCinatimelymanner.1.6OperationsTheOSChassufficientspaceavailableandradiationprotectionequipmentandothersuppliestosupportemergencyresponsepersonnelconductingre-entryactivities.TheOSChasthecapabilitytoprovide24hourcontinuousoperation,asnecessary.InitialworkactivitiesdirectedbytheOSC,attheAlertLevel,areconsideredpre-re-entryandcertainaspectsofthisproceduremayberelaxed(e.g.,HPcoverage).Followingasiteevacuationorder(evacuationoftheOwnerControlledArea)orifradiologicalconditionsexistoutsidetheRadiationControlledArea,allprovisionsofthisprocedurearerequiredforre-entryintoaffectedareas.
REVISIONNo.:PROCEDURENO.:EPIP-05PROCEDURETITLEIACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:6of5
52.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTSNOTEOneormoreofthefollowingsymbolsmaybeusedinthisprocedure:IndicatesaRegulatorycommitmentmadebyTechnicalSpecifications,ConditionofLicense,Audit,LER,Bulletin,etc.,andshallNOTberevisedwithoutFacilityReviewGroupreviewandPlantGeneralManagerapproval.Indicatesamanagementdirective,vendorrecommendation,plantpracticeorothernon-regulatorycommitmentthatshouldNOTberevisedwithoutconsultationwiththeplantstaff.
2.1REFERENCES
1.St.LuciePlantTechnicalSpecificationsUnit1andUnit2(Section6.10.1)2.St.LuciePlantUpdatedFinalSafetyAnalysisReport(UFSAR)Unit1andUnit23.St.LuciePlantRadiologicalEmergencyPlan(E-Plan)4.St.LuciePlantTopicalQualityAssuranceReport(TQAR)5.E-PlanImplementingProcedures(EPIP00-13)6.HP-200SeriesProcedures7.ADM-17.09,Invoking10CFR50.54(x)8.St.LuciePlantEmergencyResponseDirectory(ERD)9.QI-17-PSL-1,QualityAssuranceRecords10.FitnessforDutyRule,10CFR26 REVISIONNo.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:7of5
52.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTS(continued)2.2RECORDSREQUIRED1.Thefollowingshallberetainedfollowingaplantemergency:~Checklistsandpaperworkgeneratedperthisprocedure.~Logbooksmaintainedduringtheplantemergency.2.RecordedinformationshallbeforwardedtoEmergencyPlanningfollowingtheevent,forreviewandarchivalinaccordancewithTechnicalSpecification6.10.1andQI-17-PSL-1~2.3COMMITMENTDOCUMENTS1.PMAIPM97-04-142,TrainingDrillCritique1/24/97(Definitionofcontingencyteamandfullstaffingguidance),2.PMAIPM98-04-144,EvaluatedExerciseCritique3/18/98(EstablishthresholddoserateforOSCrelocation).3.PMAIPM98-09-006(ControlofNLOsUnderE-Plan)4.PMAIPM99-04-122(OpsRe-entrySupervisorRole)5.PMAIPM99-04-143(OSCCommandandControlAssistance)6.PMAIPM99-09-079(HotToolRoomAccessDuringanEmergency)3.0RESPONSIBILITIES3.1OSCSupervisor1.ProvidescommandandcontrolofOSCactivities.2.CoordinatesactivitiestoensureadequatesupporttotheTSC/EC.3.EnsuresthatallRe-entryTeamsareadequatelybriefedpriortoleavingtheOSCandthoroughlydebriefedupontheirreturn.
REVISIONNo.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:8of553.0RESPONSIBILITIES(continued)3.1OSCSupervisor(continued)4.Ensurescommunicationsflowismaintainedwithinthefacility,withtheRe-entryTeams,andwiththeTSC.5.Coordinatesfacilitybriefings.6.ArrangesforlongtermoperationoftheOSC.3.2OSCCoordinatorwithTSCServesasthecoordinatorwiththeTSCforRe-entryTeamrequests.2.Logsandtracksre-entryactivities.3.KeepstheOSCSupervisorabreastoftheemergencyconditionsandplantstatus.3.3OSCRe-entrySupervisorNOTE1.EachofthefollowingareashasaRe-entrySupervisor:(1)MechanicalMaintenance,(2)ElectricalMaintenance,(3)l8CMaintenance,(4)Operations,(5)Chemistry,and(6)HealthPhysics.2.ResponsibilitiesfortheHealthPhysicsRe-entrySupervisor(HPOSC)areprovidedinHP-200,HealthPhysicsEmergencyOrganization.1.EnsuresdepartmentalEmergencyResponseOrganization(ERO)personnelareavailableforre-entryactivities.2.AssiststheOSCSupervisorinselectionofRe-entryTeammembers.3.Providestaskspecificbriefingstotheirdepartmentalre-entrypersonnel.4.ConductsRe-entryTeamdebriefings.
REVISIONNo.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:9of553.0RESPONSIBILITIES(continued)3.4OSCDepartmentalRepresentativeNOTEThefollowingdepartmentshaverepresentativesintheOSC:(1)NuclearMaterialsManagement(NMM),(2)Safety,(3)ProtectionandControl,(4)Securityand(5)InformationServices./R51~ProvidesinputtotheOSCSupervisor,asrequestedinsupportofre-entryoperations.2.Participatesinre-entries,asneeded.4.0DEFINITIONS4.1FacilityStatus1.Activation-therequesttostaffandestablishanEmergencyResponseFacility(ERF)~2.Operational-whensufficientpersonnel(i.e.,minimumstaff)areavailabletoaccomplishthemandatoryfunctionofconductofre-entryactivities.3.FullyStaffed-thecomplementofpersonnelispresentinthefacility.4.2FPLEmergencyRecallSystem(ERS)-thecall-outsystemusedasameansofoff-hourscall-out,asdescribedinEPIP-03,EmergencyResponseOrganization/StaffAugmentation.4.3Re-entry-accesstoareaswhereevacuation(localorsite)hasbeenorderedconstitutesare-entry.Re-entryintoanevacuatedareaisauthorizedonlybytheEC.4.4Re-entryTeam-agroupofqualifiedpersonnelwhowillenteranevacuatedareaundertheauthorizationoftheECtoaccomplishanassignedtask(e.g.,repairdamagecontrol,rescue,etc.).ARe-entryTeamshallconsistofatleasttwoqualifiedpersons,oneofwhomshallbeknowledgeableinHealthPhysicsprocedures.
REVISIONNo.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:10of554.0DEFINITIONS(continued)4.5Videolink-aclosedcircuitaudio/visualcommunicationslinkoriginatingintheTSCwithfeedstotheOSCandtheEOFallowingtheECbriefingstobeavailableinalltheEmergencyResponseFacilities(ERFs).
REVISIONNo.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:11of555.0INSTRUCTIONSNOTEThissectionprovidesgeneralinformationandinstructionsforallOSCresponders.Positionspecificchecklistsareincludedasattachmentstothisprocedure.IndividualsspecificallydesignatedasmembersoftheOSCEmergencyResponseOrganization(ERO)areidentifiedintheERD.5.1Whennotified,OSCemergencyrespondersaretoreporttothefacilityasquicklyaspossible.5.2Uponarrivalatthefacility,eachOSCrespondershouldperformthefollowing:1.Sign-ininstructions:A.Personsworkinginroom2300(supervisors'rea)oftheOSCshouldsigninonthestatusboardonthesouthwallinthespacecorrespondingtotheirposition.B.AllOSCRe-entrySupervisorsshouldensurethatthenamesoftheirdepartment'sRe-entryTeammembersandforemanaresignedinonthestatusboardinRoom2300.C.TheOSCAdministrativeTech/LogkeepershouldensurethatallpersonnelinbothRooms2200and2300aresignedinonthestatusboardandthatthisinformationconcurswithAttachment2A,OSCEROShiftStaffingandAccountabilityRoster.2.Obtaina"Player"badgeandplaceyourname(andpositiontitle,ifnecessary)onthebadgewithadryerasemarkerorinanyothernon-permanentmanner.3.Obtainspecificpositionnotebook(ifapplicable)withproceduralchecklists,formsandinstructions./R5 REVISIONNO.:5PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:12of555.0INSTRUCTIONS(continued)5.2(continued)4.Makeyourworkstation/locationoperational,asnecessary.5.NotifyyoursupervisorortheOSCSupervisorofyourreadinessstatus.6.AssistinestablishingaccountabilitybysigninginonaformsimilartoAttachment2A,OSCEROShiftStaffingandAccountabilityRoster.g,5.3Onlycontrolledcopiesofnuclearsafety-relatedprocedures,drawings,andotheravailableplantinformationshallbeused.Non-controlleddocumentsordrawingsshouldbeverifiedwithacontrolledcopypriortouseintheOSC.5ADuringfacilitybriefings,stopwhatyou'edoing,payattention,andcontributeasrequested.5.5Uponterminationoftheevent:1.AllOSCpersonnelshouldreturntheirworkstations/locationstoanormalstateandassistinrestoringthefacilitytoareadycondition.2.AllOSCpersonnelshouldcollectallsignificantinformationanddocumentation,suchasnotesandcompleteddatasheets(notboundinpositionnotebooks)andforwardthismaterialtotheOSCSupervisor./R5 157OSCSUPERVISOR120TSC158OSCCoordinatorI---CoordinatorIwithOSCJwithTSC(LocatedhlheTSG)171OSCAdmln.TechiLogkeeper(2)158OSCHPervbor155OSCChemhtiySupervhor173OSCOPSRee168OSCOsi'metryTech.178RaidMon.TeamDriver(3)151OSCHPTech(12)~(8h30Minutes)!0(8Moreh80Minutes)160OSCChemht(3)0(Ih60Minutes)On4iteAA~NLOs189OSCNMMStaaRap.1650SCOnohdtSecudty170OSCSafelyReP.174OSCProL6ControlReP.152OSCBectdcidR154OSCIAehanMR153OSCIsoR158OSCeccHcalChief181OSCBectndim(3)~(1h30Minutes)0(1Moreh60asnutes)SeeNote1168OSCMecanicalForeman182OSCMechanh(3)0(2h60Mhutes)(SeeNote2)175OSCI&CShopSupervisorI,183OSC16CSpecatrm(3)~(1h30Mhutes)(SeeNote3)(PBKKPIP4SAa.14kI)Autodtaferpostdonnumbersarelistedwithpositiontitle~Sominuteresponsegoal,perNUREG0654,TBMeB-1060minuteresponsegoal,perNUREG0654,TaMoB-1Note1~MinimumstaffingrequirementsmayboINiedbyhotrfcalReentrySupervisor,ChieforElectridan.Noto2-MinimumStaffingrequirementsmaybefiNedbyMechanicalReentrySupervLsor,ForemanorMechanic.Note3-MinimumStaffingrequirementsmaybofiNNIbyl&CReentrySupervisor,ShopSupervisororl&CSpecialist.~IntfcatesminimumstaffingposidonsthatmustbefitledInordertodechrethefaciNtyoperathnaL0MOIllIllxC)z03702U)qAZl~Q~ZITI-ZN~0zzUU)C)ITlZlUC)Ol(0I00OmOZ0rn(rll0zOl00ACOOmIIm<g+0OZZ)o>zr~U)OC~UITlO~OOITlZOITl~x'zm REVISIONNo.:5PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT2OSCSUPERVISORCHECKLIST(Page1of5)PAGE:14of55NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.DetermineoperationalreadinessoftheOSCbyverifyingthefollowing:a.CommunicationsestablishedwiththeTSC.b.Minimumstaffavailable(useAttachment2A,OSCEROShiftStaffingandAccountabilityRosterorrefertothesigninboard).c.Communicationsequipmentandothersuppliesareavailableandreadyforuse.d.EnsureRoom2200setupisunderway.IftheOSCSafetyRepisnotavailable,thenreassigntheresponsibility.e.Minimumstaffpreparedtoaccomplishmandatoryfacilityfunctions.3.IfStep2aboveissatisfied,Thendeclarethefacilityoperationalat4.NotifiedtheEC/TSCSupervisorthattheOSCisoperational.
REVISIONNO.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT2OSCSUPERVISORCHECKLIST(Page2of5)PAGE:15of55B.FACILITYOPERATIONINITIALNOTE$,UnlessauthorizedbytheEC,facilitystaffingshouldbeinaccordancewithAttachment2A,OSCEROShiftStaffingandAccountabilityRoster.OSCfullystaffed.2.Instructpersonneltoverifytheirpositionnotebookproceduresagainstthepostedrevisionnumber.3.DirecttheHPOSCtoidentifyandpreparearepresentativefromHPandeachmaintenancedisciplineforarapidresponsecontingencyteam.4.InstructtheOSCAdministrativeTech/LogkeepertoinitiatetheOSCLogbook.5.Establishwhatteam(s)orindividual(s)isknowntobeworkingintheplant,thetask/job,andthecommunicationsmethod/controllingfacility.6.Identifythenecessityandmeansforprovidingaccesstoalltoolrooms(includingtheHotToolRoom)andanyotherareawithrestrictedaccess.7.ObtainfoodandwatersupplyfortheOSC.8.Arrangeforlongtermstaffing(useAttachment2A,OSCEROShiftStaffingandAccountabilityRoster).
REVISIONNo.:5PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT2OSCSUPERVISORCHECKLIST(Page3of5)PAGE:16of55B.(continued)INITIALCAUTIONTheOSCaffordslimitedprotectionagainstareleaseofradioactivematerial.Duringthetimethataradioactivereleaseisoccurring,thehabitabilityoftheOSCistobemonitored.Ameasureddoserateof50mrem/hr,inthefacility,isestablishedasthethresholdforrelocationoftheOSC.9.Ifnecessary,initiatestepsforrelocationoftheOSC(useAttachment2E,GuidelinesforRelocationoftheOSC).10.Stepstooccurcontinuallywhilethefacilityisinoperation:a.Overseecommunicationsb.Maintainlownoiselevelinthefacilityc.Conductfacilitybriefings(useAttachment2F,OSCFacilityBriefings).d.Ensureemergencystatusandplantconditionsareroutinelyupdated.(Thevideolinkmaybeusedforthispurpose.)e.Re-entryChecklist-WhenrequestedbytheOSCCoordinatorwiththeTSC,completethefollowinginresponsetoarequestforaRe-entryTeam:1~ReviewAttachment2C,Re-entryGuidelines,tothisattachmentasnecessary.2.CompletetheRe-entryTeamAssignmentsectionofAttachment3A,Re-entryLog(lettersG-Ipriortoteamdispatch).3.SelectthemostappropriateRe-entrySupervisorbasedonthenatureofthetask.
REVISIONNo.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT2OSCSUPERVISORCHECKLIST(Page4of5)PAGE:17of55B.(continued)10.(continued)e.(continued)4.AssigncompletionofPartsI,IIandIIIofAttachment5A,Re-entryTeamForm,tothechosenRe-entrySupervisor.5.DirecttheHPOSCtoassistinteamdevelopmentbysatisfyingtherequirementsofHP203.1,EvacuatedAreaRe-entryAuthorization,inHP-203,PersonnelAccessControlDuringEmergencies.6.ReviewAttachment2D,BriefingGuidelines,tothisprocedure,asnecessary.7.WhenrequestedbytheassignedRe-entrySupervisor,completePartIVofAttachment5A,Re-entryTeamForm.8.RecordTimeoutintheRe-entryTeamAssignmentsectionofAttachment3A,Re-entryLog(letterJ).9.InstructtheOSCCoordinatorwiththeTSCtoprovidetheinformationintheRe-entryTeamAssignmentsectionofAttachment3A,Re-entryLog(lettersG-J)totheTSC.10.WhentheteamreturnstotheOSC,completePartVlofAttachment5A,Re-entryTeamForm.11.RecordTimeinandanycommentsintheRe-entryTeamAssignmentsectionsofAttachment3A,Re-entryLog(lettersKandL).12.InstructtheOSCCoordinatorwiththeTSCtoprovidetheinformationintheRe-entryTeamAssignment,sectionofAttachment3A,Re-entryLog(lettersKandL)totheTSCtocloseouttheRe-entryTeam.
REVISIONNO.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT2OSCSUPERVISORCHECKLISTPAGE:18of55(Page5of5)C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.AllRe-entryTeamsareloggedbackinandaccountedfor.2.Allfacilityactivitiesclosedout.3.Allequipmentandsuppliesreturnedtopreactivationconditionand/orlocation.4.Allpaperworkcollected.5.ClosedouttheOSCLogbook.6.Returnedpositionnotebooktostorageshelf.7.Providedallcompletedpaperwork(notboundinpositionnotebooks)toEmergencyPlanning./R5 REVISIONNo.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:19of55ATTACHMENT2AOSCEROSHIFTSTAFFINGANDACCOUNTABILITYROSTER(Page1of4)POSITION{Minimumstaffinbold'Shife,Hours:NAMEToBADGENO.OSCHPSupervisor:OSCHPTech':OSCHPTech':OSCHPTech':OSCHPTech':OSCHPTech':OSCHPTech':OSCHPTech':OSCHPTech':OSCHPTech':OSCHPTech':OSCHPTech':OSCHPTech':OSCDosimetryTech:FieldMonTeamDriver:FieldMonTeamDriver:FieldMonTeamDriver:
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:20of55ATTACHMENT2AOSCEROSHIFTSTAFFINGANDACCOUNTABILITYROSTER(Page2of4)POSITIONOSCl&CRe-entIySupv:OSCIBCShopSupervisor:OSCl&CSpecialist:OSCIBCSpecialist:OSCI&CSpecialist:OSCMechRe-entrySupv:OSCMechanicalForeman:OSCMechanic:OSCMechanic:OSCMechanic:OSCElecRe-entIySupv:OSCElectricalChief:OSCElectrician:OSCElectrician:OSCElectrician:NAMEBADGENO.
REVISIONNO.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:21of55ATTACHMENT2AOSCEROSHIFTSTAFFINGANDACCOuNTABILITYROSTER(Page3of4)POSITIONOSCSupervisor:OSCCoordinatorwithTSC:OSCChemistrySupv.:OSCChemist:OSCChemist:OSCChemist:OSCOn-ShiftSecurity:OSCOn-ShiftSecurity:OSCOn-ShiftSecurity:OSCOPSRe-entrySupv:OSCProtandControlRep:OSCNMMStaffRep:OSCSafetyRep:OSCInformationServicesRep:OSCAdminTech/Logkeeper:OSCAdminTech/Logkeeper:AssemblyAreaSupervisor:NAMEBADGENO./R5 REVISIONNo.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:22of55ATTACHMENT2AOSCEROSHIFTSTAFFINGANDACCOUNTABILITYROSTER(Page4of4)POSITIONNAMEBADGENO.Other:'Longtermstaffing,refertotheSt.LuciePlantEmergencyResponseDirectory(ERD)forpositionalternates.'RefertoAttachment2Bfortemporaryalternatesforminimumstaffpositions.'Positionfillsthefollowingpositions:a.TSCHPSurveys1.Unit1ControlRoom/TSC2.Unit2ControlRoom3.OSC4.AccessControlb.HPFieldTeams1.RedTeam2.OrangeTeam3.BlueTeam REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT2BOSCMINIMUMSTAFFING(Page1of1)PAGE:23of55MajorFunctionalArea'ositionTitleandIDNo.'ealthPhysicsTechnicianOSCHPTech,151¹inPositionQualifications/TemporaryAlternate12MemberoftheHealthPhysicsDepartmentRad/ChemTechnicianElectricalMaintenanceMechanicalMaintenance/RadwasteOperatorI&CTechnicianFacilityCommandandControlOSCChemist,160OSCElectrician,161OSCMechanic,162OSCl&CSpecialist,163OSCSupervisor,157MemberoftheChemistryDepartmentElectricalMaintenanceJourneymanorChieforSupervisorMechanicalMaintenanceJourneymanorForemanorSupervisorI&CMaintenanceSpecialistorSupervisorOSCCoordinatorwithTSCThisfunction(s)maybeaccomplishedduringthefirst75minutesofanemergencybyanindividual(s)meetingthecorrespondinglistedqualifications.TheseEmergencyResponseOrganization(ERO)positionswereestablishedtoaccomplishtheindicatedfunction(s).
REVISIONNo.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT2CRE-ENTRYGUIDELINES(Pageosof3)PAGE:24of55CAUTIONAsspecifiedinADM-17.09,Invoking10CFR50.54(x),theEmergencyCoordinator(EC)may(withtheconcurrenceofalicensedsenioroperator)waivere-entryrequirementstoplacetheplantinasafeshutdownconditionormitigatearelease,ifthisimmediateactionisneededtoprotectthehealthandsafetyofthepublic./R5PriortoevacuationandwiththeOperationalSupportCenter(OSC)NOToperational.Re-entryguidelinesdonotapply.2.PriortoevacuationandwiththeOSCoperational.a.OperatorsinthefieldshouldreturntotheControlRoomsandobtainanElectronicPersonalDosimeter(EPD)fromtheHealthPhysicsEmergencyKitpriortoreturningtofield.b.SinceteamsmaybedispatchedfromtheOSCpriortoevacuationofanyplantareas,theOSCSupervisorandHealthPhysicsSupervisorintheOSC(HPOSC)shouldevaluatetheeventinprogressanddeterminethemostlikelytrendsinradiologicalconditions.Iftheeventislikelytoresultinevacuation(s),duetoradiologicalconcerns,theteamsshouldbedressed,equipped,andbriefed,similarlytoRe-entryTeams.3.EvacuationorderedandwiththeOSCNOToperational.Operatoractionsinthefieldmustbeviewedasre-entryactivities.OperatorsshallreturntotheControlRoomsfollowingtheevacuationorder.OperatorsshallobtainanElectronicPersonalDosimeter(EPD)fromtheHealthPhysicsEmergencyKit,ifnotdonepreviously.Re-entryintotheplantrequires:/R5a.TheEC(initiallytheNPS)authorizetheentry.b.Maintenanceofappropriateradiologicalandsafetymeasures.c.Trackingthewhereaboutsoftheteam./R5 REVISIONNo.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT2CRE-ENTRYGUIDELINES(Page2of3)PAGE:25of554.EvacuationorderedandwiththeOSCoperationala.NLOs,frombothUnits,aretoreporttotheOSConceitgoesoperational./b.Allfieldactivitiesarere-entriesandshallbecoordinatedandcontrolledbytheOSC./R5c.Re-entryintoanevacuatedareashallbemadeonlywhenauthorizedbytheECandunderthedirectionoftheTSCHPSupervisor(TSCHPS)andtheHPOSCforoneormoreofthefollowingreasons:1.Toascertainthatallpersonnelwhowereintheaffectedareahavebeenevacuatedandtosearchforunaccountedforpersonnel.2.Toassistinevacuatinginjuredorincapacitatedpersonnelfromtheaffectedarea.3.Toperformoperationswhichmitigatetheeffectoftheemergencyorhazardouscondition.4.Todeterminethenatureandextentoftheemergencyand/orradiologicalconditions.5.Toestablishdefinitepersonnelexclusionareaboundaries.
REVISIONNo.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT2CRE-ENTRYGUIDELINES(Page3of3)PAGE:26of555.GeneralConsiderationa.TheRe-entryTeammembersshouldbeselectedbasedonappropriatequalificationsrelevanttothepurposefortheentry.b.ARe-entryTeamshallconsistofatleasttwoqualifiedpersons,oneofwhomshallbeknowledgeableinHealthPhysicsprocedures.c.Themostqualified(relativetotheentry)personshouldbeselectedtoserveastheRe-entryTeamLeader.He/sheshouldbefullybriefedconcerningthenatureoftheemergencyandtheexpectationsfortheentry.d.AllRe-entryTeammembersshallwearprotectiveclothing,dosimeters,respiratorydevices,andotherprotectivedevicesasspecifiedbytheHPOSC.e.AcontingencyRe-entryTeamshouldbedevelopedconsistingofrepresentativesfromeachofthemaintenancedisciplinesandHealthPhysics.Thisteamanticipatestheneedforahighpriority,rapidresponserequestfromtheEC/TSC.
REVISIONNO.:PROCEDURENo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERPAGE:27of55EPIP-05ST.LUCIEPLANTATTACHMENT2DBRIEFINGGUIDELINES(Page1of1)PRE-ENTRY1.TheRe-entryTeamFormtakestheplaceofaNuclearPlantWorkOrder(NPWO)package,therefore,carefuldocumentationisrequired.2.EnsurethattheRe-entryTeammembersareinstructedastowhatisrequiredofthemduringtheentrybytheassignedRe-entrySupervisor.3.EnsurethattheRe-entryTeammembersarebriefedconcerningthenatureoftheemergencyandthepossibleradiationhazardspresentbytheHPOSC.4.VerifythattheRe-entryTeamunderstandsthattheyshouldnotdeviatefromtheplannedrouteandtask,unlessduetounanticipatedcircumstancessuchasrescue,performinganoperationwhichwouldminimizetheemergencycondition,etc.andonlyafteracknowledgementfromtheOSC.5.VerifythattheRe-entryTeamunderstandsthatifthemonitoreddoseratesencounteredduringtheentryexceedthelimitssetbytheHPOSCthattheTeamshouldreturntotheOSCor,ataminimum,movetoanareaoflowbackgroundandreviewconditionswiththeOSC.6.IfaRe-entryTeamistobeassignedaneworadditionaltaskwhilestillinthefield,PartII,TaskAssessment,ofAttachment5A,Re-entryTeamForm,mustbere-evaluatedbyanappropriateRe-entrySupervisorandtheHPOSCconsulted,priortoprovidingafieldbriefing.POSTENTRY1.EvaluatethesuccessoftheRe-entryTeamincompletingthere-entrytask.2.EnsurethatPartV,TeamWorkReport,oftheRe-entryTeamForm(Attachment5A)iscompletedbytheRe-entryTeamfordocumentation.
REVISIONNo.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT2EGUIDELINESFORRELOCATIONOFTHEOSC(Page1of2)PAGE:28of55a.~DSGSInconjunctionwiththeEmergencyCoordinatorandtheTSCHPSupervisor,obtainapprovaltorelocatetheOSCtooneofthefollowinglocations:(notinanypriority)a.NorthServiceBuilding,conferenceareaormaintenanceshopsb.BlowdownBuildingc.UnaffectedReactorAuxiliaryBuilding(RAB)d.Otherlocationdeemedappropriate2.Organizethreerelocationteamsasfollows:a.SETUPTEAMtopreparethealternateOSClocation.b.EQUIPMENTANDSUPPLYTEAMtoarrangeforandtransportequipmenttothealternateOSClocation.c.TURNOVERTEAMtomaintaincontinuitywiththeTSCandcommunicationswiththeSetUpTeam.3.EnsurethatcommunicationsareestablishedandcheckedatthealternateOSC.4.NotifytheTSCandEmergencyCoordinatorthatthealternateOSCisoperationalandtheprimaryOSChasbeenshutdown.B.MaintenanceRe-entSuervisors1.Identifytoolsandequipmentfortransfer.2.Makevehiclesavailabletotransportequipment.3.MaintaincommunicationswithRe-entryTeams.
REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERPAGE:29of55EPIP-05ST.LUCIEPLANTATTACHMENT2EGUIDELINESFORRELOCATIONOFTHEOSC(Page2of2)C.HPandChemistDeveloparelocationbriefingregardingradiologicalconditionsandtravelroute.2.ChemistryassistHPingatheringEmergencyKitequipment,dosimetry,andexposurerecordsandpreparefortransport.3.Atthenewlocation,reestablish:a.Accesscontrolb.Habitabilitysurveysc.DeconlocationD.~Securit1~Reestablishaccountabilityatthenewlocation.2.EnsurethatthealternatelocationisidentifiedtoSecurityroadblocks.E.AdminTechandLokeeer1.CreateanewlayoutfortheOSCinthealternatelocation,asnecessary.2.CreateanewcalllistofOSCphonenumbersinthealternatelocation.a.Aminimumoften(10)phonelinesshouldbeidentified,includingonelineforatelecopymachine,ifamachineisavailable.(1)Radiochannelsmayneedtobesubstitutedformissingphonelines.3.Ensureallstatusboardinformationisrecordedandtransferred.
REVISIONNo.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT2FOSCFACILITYBRIEFINGS(Page1of1)PAGE:30of55A.GENERALGUIDELINES1~ConductedbytheOSCSupervisororhis/herdesignee.2.Establishafrequency(e.g.,every30minutesordirectlyfollowingtheECportionoftheTSCbriefingsviathe"Videolink").3.Setcriteria(i.e.,attendance,noiseandactivitylevel,circulationofinformation).B.GENERALFORMAT-thefollowinginformationshouldbeincludedinfacilitybriefings.1.Timeofthebriefing2.Currentemergencyclassification3.Plantstatus(affectedUnit,unaffectedUnit)4.Radiologicalconditions(e.g.,releaseinprogress,contaminatedareas,etc.)5.Statusofprotectiveactions(e.g.,siteevacuation,actionsunderwaybythepublic,etc.)6.Statusofactivitiesunderwayinthefacility7.Requestinput/updateinformationfromotherrepresentatives(e.g.,OPS,HP,Chem,Maintenance,Engineering,Security,etc.)8.Majoractivity(s)underwayinotherfacilities(e.g.,notifications,fieldmonitoring,doseassessment,etc.)9.Concernsorquestions REVISIONNo.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT3OSCCOORDINATORWITHTSCCHECKLIST(Page1of2)PAGE:31of55NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.EstablishcommunicationlinkwiththeTSCCoordinatorwithOSC(intheTSC).3.SynchronizeOSCclockswiththeTSC.B.FACILITYOPERATION1.Stepstooccurcontinuallywhilethefacilityisinoperation:a.Ensureallrequestsforre-entryactivitiesaredocumentedonAttachment3A,Re-entryLog.CompletetheRe-entryTaskRequestsectionofAttachment3A(lettersA-F)withinformationprovidedbytheTSCCoordinatorwithOSC.b.Ensureallre-entryrequestshavebeenapprovedandprioritizedbytheEC.c.GivetheRe-entryLogtotheOSCSupervisorforcompletionoftheRe-entryTeamAssignmentsection.
REVISIONNo.:PROCEDURENo.:EPIP-05B.(continued)PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT3OSCCOORDINATORWITHTSCCHECKLIST(Page2of2)PAGE:32of55INITIAL(continued)d.UponreturnoftheRe-entryLogformfromtheOSCSupervisor:1~ProvidetheinformationintheRe-entryTeamAssignmentsectionofAttachment3A,Re-entryLog(letters8-I)totheTSC.2.InstructtheOSCAdministrativeTech/LogkeepertoupdatetheOSCStatusBoardwithRe-entryTeaminformation.e.InformtheOSCSupervisorwhentheEC/TSCwillbeconductingafacilitybriefing.f.Monitorinformationonthestatusboardforaccuracy.g.ProvidetemporarycoveragefortheOSCSupervisorduringRe-entryTeambriefingsanddebriefings,asrequested.C.FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.PhoneconnectiontoTSCterminated.2.AllRe-entryLogentriescompletedandclosedout.3.Providedailcompletedpaperwork(notboundinthepositionnotebook)totheOSCSupervisor.4.Returnedpositionnotebooktostorageshelf./R5/R5 REVISIONNO.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT3ARE-ENTRYLOG(Page1of1)PAGE:33of55RE-ENTRYTASKREQUESTCompletethissectionwithinformationfromtheTSCCoordinatorwithOSC.RE-ENTRYTEAMASSIGNMENTTheOSCSupervisorshouldcompletethissection.A.TaskDescription:B.*Priority:C.Time:D.Reasonforrequest:E.Infocontact:F.Phone:A.TaskDescription:B.*Priority:C.Time:D.Reasonforrequest:E.Infocontact:F.Phone:A.TaskDescription:B."Priority:C.Time:D.Reasonforrequest:E.Infocontact:F.Phone:A.TaskDescription:B.*Priority:C.Time:D.Reasonforrequest:E.Infocontact:F.Phone:A.TaskDescription:B."Priority:C.Time:D.Reasonforrequest:E.Infocontact:F.Phone:G.TeamNo.:H.Title:I.Re-entrySupv.:J.Timeout:L.Comments:G.TeamNo.:H.Title:I.Re-entrySupv.:J.Timeout:L.Comments:G.TeamNo.:H.Title:I.Re-entrySupv.:J.Timeout:L.Comments:G.TeamNo.:H.Title:I.Re-entrySupv.:J.Timeout:L.Comments:G.TeamNo.:H.Title:I.Re-entrySupv.:J.Timeout:L.Comments:K.Timein:K.Timein:K.Timein:K.Timein:K.Timein:*0=Dispatchinlessthan5minutes(e.g.,fire,injury,orcertainOperatorActions)1=Dispatchinlessthan15minutes(e.g.,EmergencyCoordinatortoppriority)2=Dispatchinlessthan30minutes(e.g.,routinere-entries)
REVISIONNo.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:34of55ATTACHMENT4OSCADMINISTRATIVETECH/LOGKEEPERCHECKLIST(Page1of2)NOTE1.Twopersonsserveinthisposition.AdivisionoflaborshouldbeestablishedthatbestsupportstheOSCSupervisor.2.Whennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIALRefertosection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.EnsurestatusboardsintheOSCarecleanpriortofacilityactivation.3.Ensurethetelevisionsetsinropms2200and2300areturnedonandsetonchannel9(forthe"Videolink").B.FACILITYOPERATION1.EnsurethatallpersonnelinbothRooms2200and2300aresignedinonthestatusboardandthatthisinformationconcurswithAttachment2A,OSCEROShiftStaffingandAccountabilityRoster.2.Stepstooccurcontinuallywhilethefacilityisinoperation:a.MaintaintheOSCSupervisorLogbookonceturnedoverfromOSCSupervisor(useAttachment4A,LogKeepingandStatusBoards).b.MaintaintheOSCStatusBoard(useAttachment4A,LogKeepingandStatusBoards)~c.ReviewstatusboardentrieswiththeOSCCoordinatorwithTSCtoensureaccuracy.d.ProvideadministrativeassistanceandsuppliestotheOSCSupervisorandRe-entrySupervisors(suppliesareavailableintheHPEmergencyKit).
REVISIONNo.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:35of55ATTACHMENT4OSCADMINISTRATIVETECH/LOGKEEPERCHECKLIST(Page2of2)C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.Thestatusboardhasbeenclearedandreturnedtopreactivationcondition.2.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheOSCSupervisor.3.Returnedpositionnotebooktostorageshelf./R5 REVISIONNo.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT4ALOGKEEPINGANDSTATUSBOARDS(Page1of1)PAGE:36of55LOGKEEPING1.Exampleofinformationtobedocumenteda.Keyevents(e.g.,classificationchanges,injuries,etc.)b.Statuschangesinequipment,radiologicalconditions,personnel,etc.c.Decisionsoractionstakend.Statusboardentriese.Otheritemsofsignificance2.Logentryrequirementsa.Timeofentryb.Useinkc.Writelegiblyd.Useconciseandaccuratewordinge.Strikethroughandinitialanychangesf.DonotremovepagesfromthelogSTATUSBOARDS1.Informationshouldbeupdatedevery15-30minutesandnotlongerthan60minutes.2.Reviewpostedinformationforaccuracy(e.g.,reviewtheRe-entryTeamnumberagainsttheRe-entryLog)andverifydiscrepancieswiththeOSCCoordinatorwithTSC.3.Designatecorrectedinformationbycirclingtheentryontheboard.4.Whenallavailableblanksarefilledinforagivenparameter/item,beginagainwithadifferentcoloredmarker,erasetheexistinginformation(oneblank/lineatatime)andenterthenewinformation.
REVISIONNO.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT5OSCRE-ENTRYSUPERVISORCHECKLIST(Page1of4)PAGE:37of55NOTE1.ThischecklistappliestothefollowingRe-entrySupervisorpositions(responsibilitiesoftheOSCHPRe-entrySupervisor(HPOSC)areprovidedinHP-200,HealthPhysicsEmergencyOrganization):OSCElectricalRe-entrySupervisorOSCMechanicalRe-entrySupervisorOSCOPSRe-entrySupervisorOSCl&CRe-entrySupervisorOSCChemistrySupervisor2.ThisattachmentalsoprovidesguidelinesforthefollowingRe-entryTeammembers:OSCElectricianOSCMechanicOSCNonLicensedOperatorsOSCl&CSpecialistOSCChemist3.Whennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1~Refertosection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.Assistinpreparationandset-upoftheOSC.NOTE1.Initially,on-shiftNon-LicensedOperators(NLOs)areunderthecontroloftheNPSandareaccountedforontheOperationsAccountabilityAid.Followingsiteevacuation,NLOsreporttotheOSCandarethenconsideredpartoftheOSCstaff.2.Extra(nonon-shift)NLOsreporttotheOSCandarepartoftheOSCstaff.3.EnsuredepartmentalRe-entryTeammembersaresigned-inonaformsimilartoAttachment2A,OSCEROShiftStaffingandAccountabilityRoster.4.ProvideactivationstatusofyourgrouptotheOSCSupervisor.
REVISIONNO.:5PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT5OSCRE-ENTRYSUPERVISORCHECKLIST(Page2of4)PAGE:38of55B.FACILITYOPERATIONINITIALAllRe-entrySupervisorsinitiateaLogbook.2.StepstooccurcontinuallybyallRe-entrySupervisorswhilethefacilityisinoperation:a.MaintaindocumentationofactivitiesintheLogbook.b.Re-entryChecklist-WhendirectedbytheOSCSupervisorcompletethefollowinginresponsetoarequestforaRe-entryTeam:1.CompletePartI,TeamAssignment,portionofAttachment5A,Re-entryTeamForm,asrequestedbytheOSCSupervisorbyselectingRe-entryTeammembersandaRe-entryTeamLeader.2.WorkwithothermembersoftheOSCstafftocompletePartII,TaskAssessment,oftheRe-entryTeamForm.3.ReviewAttachment5B,Re-entryTeamGuidelines,asnecessary.4.CompletePartIII,TeamPre-entryBriefing,ofAttachment5A,Re-entryTeamForm.5.ProvidetheRe-entryTeamFormtotheOSCSupervisorforcompletionofPartIV.6.Oncedispatched,communicatewiththeRe-entryTeamandkeeptheOSCSupervisorinformedofstatus/activities.7.UponreturntotheOSC,directtheRe-entryTeamtocompletePartV,TeamWorkReport,ofAttachment5A,Re-entryTeamForm.8.RetaincompletedcopiesofAttachment5A,Re-entryTeamForm.
REVISIONNo.:PROCEDURENo.:EPIP-05B.(continued)PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT5OSCRE-ENTRYSUPERVISORCHECKLIST(Page3of4)PAGE:39of55INITIAL2.(continued)c.CoordinateshiftreliefactivitieswiththeOSCSupervisor.d.PerformshiftturnoverwithanalternateRe-entrySupervisor,whendirected.Ensureshiftturnoverofotherdepartmentalre-entrypersonnel.$43.OPSRe-EntrySupervisora.EstablishlinkwithOPSConferenceBridge(originatedintheTSC).NOTEAtsiteevacuationandatthedirectionoftheEC,NLOswillreporttotheOSC.b.Verifythaton-shiftNLOsareawareofthefollowing(maybecommunicatedthroughtheControlRoomordirectly):1.Emergencydosimetry(ElectronicPersonalDosimeter(EPD)),intheControlRoomHPEmergencyKits,mustbeusedatALERTorhigheremergencyclass.2.TheECwilldirecttheNLOstotheOSCfollowingasiteevacuation.3.TravelroutetotheOSCwillbeestablishedbytheHPOSC.
REVISIONNo.:PROCEDURENO.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERPAGE:40of55EPIP-05ST.LUCIEPLANTATTACHMENT5OSCRE-ENTRYSUPERVISORCHECKLIST(Page4of4)B.(continued)INITIAL3.(continued)CAUTIONAsspecifiedinADM-17.09,Invoking10CFR50.54(x),theEmergencyCoordinator(EC)may(withtheconcurrenceofalicensedsenioroperator)waivere-entryrequirementstoplacetheplantinasafeshutdownconditionormitigatearelease,ifthisimmediateactionisneededtoprotectthepublichealthandsafety.c.CoordinateoperatoractionsovertheOPSConferenceBridgeandinconjunctionwiththeOSCSupervisor.C.FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.Directeddepartmentalpersonneltoturnindocumentation.2.ClosedouttheLogbook.3.GenerateNuclearPlantWorkOrders(NPWOs),followingterminationoftheemergency,toensureallmaintenanceactivitiesarerecordedinplantmaintenanceprogramrecords,asnecessary.4.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheOSCSupervisor./R55.Returnedpositionnotebooktostorageshelf.
REVISIONNo.:5PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT5ARE-ENTRYTEAMFORM(Page1of2)PAGE:41of55NOTEThisformtakestheplaceofaNuclearPlantWorkOrder(NPWO)package,therefore,carefuldocumentationisrequired.PARTI~TEAMASSIGNMENTA.TeamNo.:B.Title:E.TeamMembers:NameTLDNo.C.Priority:D.Time:Department5.F.DesignatedTeamLeader:G.Completedby:,Re-entrySupervisorCAUTIONIFtheRe-entryTeamisassignedaneworadditionaltask,THENthissectionshallbere-evaluatedandtheHPOSCconsulted,priortothefieldbriefing.PARTII.TASKASSESSMENTA.Taskdescription:B.Clearanceconsideration(OPS):C.Security:D.Safety/HeatStress:E.Materialavailable(NMM):F.Tools:G.InstructionLevel:H.Workguidelines:I.Completedby:PARTIII.TEAMPRE-ENTRYBRIEFINGA.Reviewtaskassessment:B.Specialinstructions:,Re-entrySupervisorC.Communications,primary:D.Completedby:alternate:,Re-entrySupervisor REVISIONNo.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATi'ACHMENT5ARE-ENTRYTEAMfORM(Page2of2)PAGE:42of55PARTIV.TEAMDISPATCHA.Teamunderstandsthere-entrytask?B.Teamhasnecessarymaterials,tools,andprotectiveequipment?C.HPre-entrybriefingcomplete?D.Other:E.TimeOut:F.Completedby:,OSCSupervisorPARTV.TEAMWORKREPORTA.Report:B.Reportcompletedby:PARTVI.TEAMEXITDEBRIEFA.Timein:B.Taskstatus:C.Additionalinformation(problems/hazards):D.Teamcloseout:E.Completedby:F.HPForm203.1CompletedbyG.Reviewedby:H.NPWOgeneratedby:,Re-entrySupervisor,HPOSC,OSCSupervisor,Re-entrySupenrreor,Date~~
REVISIONNo.:5PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT5BRE-ENTFIYTEAMGUIDELINES(Page1of1)PAGE:43of55MEMBERSOFRE-ENTRYTEAMS:1~Shouldobtain,asappropriate,tools,equipment,supplies,andcommunicationsequipmentnecessarytoperformemergencyrepair/damagecontrolactivities.2.ShouldreportanyequipmentorsupplyproblemstotheRe-entrySupervisor.3.Shalldonpersonalprotectiveequipment/clothinganddosimetry,ifdirectedbytheHPOSC.4.Shouldproceedalongthepre-plannedroutetotheworklocationandperformemergencyrepair/damagecontrolactivities,asdirectedbytheRe-entrySupervisor,HPOSC,andOSCSupervisor.5.ShouldmaintaincommunicationswiththeRe-entrySupervisor.6.Shouldrequestadditionalpersonnel/equipment,asnecessary,throughtheRe-entrySupervisor.7.Shallcheckdosimetry/monitorexposure.IfthealarmoftheElectronicPersonalDosimeter(EPD)sounds,followtheinstructionsprovidedbytheHPOSC.8.Shouldfollowtheself-monitoringandpersonneldecontaminationproceduresasspecifiedbytheHPOSC,whenthere-entryiscomplete.9.ShouldcompletePartV,TeamWorkReport,inAttachment5A,Re-EntryTeamForm,andreporttotheOSCSupervisorfordebriefonreturntotheOSC.10.ShouldreporttoHPforexposurehistoryupdate.11~Shouldstand-byforfurtherinstructionsfromtheRe-entrySupervisor.
REVISIONNO.:PROCEDURENo.EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT6OSCRE-ENTRYFOREMANCHECKLIST(Page1of2)PAGE:44of55NOTE1.ThischecklistappliestothefollowingRe-entryForemanpositions:OSCElectricalChiefOSCMechanicalForemanOSCIBCShopSupervisor2.Whennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1~Refertosection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.AssisttheRe-EntIyTeamSupervisorinidentificationofdepartmentaljourneyman.B.FACILITYOPERATION1~Stepstooccurcontinuallywhilethefacilityisinoperation:a.AssisttheRe-entrySupervisorinre-entryactivitiesasfollows:1~Evaluationofre-entrytasks.2.Selectionofdepartmentalpersonnelforre-entrytasks.
REVISIONNo.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT6OSCRE-ENTRYFOREMANCHECKLIST(Page2of2)PAGE:45of55B.(continued)(continued)a.(continued)INITIALNOTE1.AcomputerprovidesaLANconnectionandaccesstotheTotalEquipmentDatabase(TEDB)inPassport.2.Procedures,TechManuals,anddrawingsareavailableacrossthehallfromtheOSCintheMaintenanceLibrary(anInformationServicesrepresentativeispartoftheOSCstaff,ifneeded).3.DeterminationoflevelofinstructionneededbytheRe-entryTeammembers.4.Selectionoftools,equipment,andsuppliesnecessarytoperformemergencyrepair/damagecontrolactivities.b.PerformasaRe-entryTeamLeader,asdirected.C.FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.Directeddepartmentalpersonneltoevaluatestatusofequipmentandsuppliesandreportdeficiencies.2.HaddepartmentalRe-entryTeammembersreturnallequipmentandsuppliestonormal/storagelocations.3.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheOSCSupervisor./R54.Returnedpositionnotebooktostorageshelf./R5 REVISIONNo.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT7OSCDEPARTMENTALREPSCHECKLIST(Page1of3)PAGE:46of55NOTE1~ThischecklistappliestothefollowingOSCDepartmentReps:OSCSafetyRepOSCNMMStaffRepOSCProtectionandControlRepOSCInformationServicesRep2.Whennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence./R5A.FACILITYACTIVATIONINITIAL1~Refertosection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.OSCInformationServicesRepa.Verifyproceduresbypostingrevisionnumbersonthestatusboard.Postallprocedures(EPIP,HP,Chem).ConsultthecontrolcopyofproceduresintheOSCHPEmergencyKitorfollowthestepsbelowtoprintoutanEPIPlist.(1)InLotusNotes,clickonthePSLProceduresicon.(2)OntheSearchlinetoolbar,clickthefarrightbutton(with2circlesandadownarrow).(3)SelectGroupSearchfromthedropdownmenu.(4)IntheSearchlinetype"EP"(wherethe"XX"is).(5)ClickSearchorhitEnter.(6)EPIPlistisnowdisplayed(notinanyparticularorder).
REVISIONNo.:5PROCEDURENO.:EPIP-05A.(continued)PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT7OSCDEPARTMENTALREPSCHECKLIST(Page2of3)PAGE:47of55INITIAL2.(continued)a.(continued)(7)Toprintthelist:ClicktheFile.SelectPrintfromthedropdownmenu.SelectViewOptionsinthedialoguebox.ClickOK.b.EnsurecopiesoftheEmergencyResponseDirectory(ERD)areavailableforusebytheOSCSupervisorandOSCRe-entrySupervisors.CopiesoftheERDmaybeobtainedfromtheHPEmergencyKit.3.OSCSafetyRep(orasdesignatedbytheOSCSupervisor)a.InitiatesetupofRoom2200inaccordancewithAttachment7A,Room2200Guidelines,and7B,Room2200SetUp.B.FACILITYOPERATIONNOTEComputersareavailableinRoom2300foraccessingtheLAN,asneeded.1.Stepstooccurcontinuallywhilethefacilityisinoperation:a.OSCSafetyRep(orasdesignatedbytheOSCSupervisor)(1)SuperviseactivitiesinRoom2200.FollowtheguidanceprovidedinAttachment7A,Room2200Guidelines.
REVISIONNo.:5PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT7OSCDEPARTMENTALREPSCHECKLIST(Page3of3)PAGE:48of55B.FACILITYOPERATION(continued)(continued)b.EachrepresentativeshouldbealerttoassisttheOSCSupervisorinadvisingRe-entIyTeamsorparticipatinginre-entryasneeded.c.Providesupportand/orexpertiseasfollows:1.OSCNMMStaffRep-materialsandequipmentinStoresINITIAL2.OSCProtectionandControlRep-off-sitepowerandswitchyardissues3.OSCInformationServjcesRep-obtainand/orproducecopiesoftechmanuals,drawings,procedures,diagramsandothercontrolleddocuments,asrequested.C.FACILITYCLOSEOUTANDRESTORATION/R5NOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheOSCSupervisor.2.Returnedpositionnotebooktostorageshelf./R5/R5 REVISIONNo.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT7AROOM2200GUIDELINES(Page1of3)PAGE:49of55A.SETUPInstructpersonneltoarrangethetablesandchairsinaccordancewiththefacilitylayoutshowninAttachment7B,Room2200SetUp.Eachdepartmentshouldensuretheirareaisproperlylocatedandarranged.2.TheOSCSupervisorshouldbeadvisedwhentheroomissetup.B.STAFFANDACCOUNTABILITY1.AssistSecurityinestablishingaccountabilitybyinstructingallpersonneltosigninonAttachment2A,OSCEROShiftStaffingandAccountabilityRoster.Instructallforementoensuretheirpersonnelaresignedin.2.EnsureonecompletedcopyofAttachment2AisprovidedtotheOSCSupervisorandanothercompletedcopyisgiventooneoftheOSCAdministrativeTech/Logkeepers.C.CONDUCTOFFACILITYOPERATIONS1.IdentifyandprocesspersonnelfromHP,OPS,Chemistryand,Maintenancetoinitiallyestablisharapidresponse/contingencyRe-entry'eam.2.Reviewtherules:a.Orderlyconductistobemaintainedatalltimes.b.PersonnelaretolistentoTSCbriefingsbroadcastovertheVideolink.c.BriefingswilloccurfollowingtheTSCbriefings(approximatelyevery30minutes)andwillallowforquestions.d.PersonnelareallowedtoleaveRoom2200(tousethebathroom,makecopies,gotheMaintenanceLibrary,etc.),butmustnotifytheirforemanifappropriate,andinallinstances,signoutonrosterprovidedbySecurity.e.PersonnelareNOTtoenterRoom2300unlessinstructedtodoso.
REVISIONNo.:5PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT7AROOM2200GUIDELINES(Page2of3)PAGE:50of55C.(continued)3.Havepersonnelidentifyanytools,instrumentsorothersuppliesthatarenecessaryfortheirresponseefforts.TheserequestsneedtobeprovidedtotheOSCSupervisorsothatarrangementscanbemadetoobtainthismaterial.D.HPBRIEFINGS1~Inadditiontore-entryspecificbriefings,HPshouldroutinelyprovidegeneralHPbriefingstopersonneladdressingthefollowing:a.LocationoftheAccessControlPoint.b.Currentdressoutrequirements.c.Dosimetry,alarmsetpoints,andappropriateactionsifanalarmshouldsound.d.Generalradiologicalconditionsbasedonon-sitesurveydata.e.RadiologicalconditionsintheOSC.f.Releaseordoseconcerns.E.SAFETYBRIEFINGS1~Safetyconsiderationsassociatedwithre-entriesshouldinclude:a.Clearanceconsiderations.b.Cautioninunknownenvironments,forexample,bewaryofsteamleaksorotherpotentiallydangerousconditions.c.Personalsafetywithrespecttoyourphysicalcondition,forexample,remainsensitivetothedangersofHeatStress.d.Befamiliarwithsurroundingsandalerttochangingconditions.
REVISIONNo.:PROCEDURENo.:EPIP-05E.(continued)PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT7AROOM2200GUIDELINES(Page3of3)PAGE:51of551~(continued)e.KeepincontactwiththeRe-entrySupervisor.f.Performtheworkassafelyaspossible.2.Wheninthefield,alwaysreviewanyproposedchangeinthere-entryplan(ingress,egress,orassignedtask)withtheRe-entrySupervisor.
REVISIONNO.:5PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT7BROOM2200SETUP(Page1of1)PAGE:52of55\~~3I:>~<i)gQ<i.UI"PsrQi!r~<<QQQQQQQQQQHEALTHPHYSICSEMERGENCYImCPERATONSo@ssssyQ000000IItllia>Ass/R5 REVISIONNo.:5PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT8OSCSECURITYCHECKLIST(Page1of3)PAGE:53of55NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.NOTEPriorityisgiventoidentifyingtheminimumstaff(positionsinboldonAttachment2A)whichallowstheOSCSupervisortodeclaretheOSCoperational.AccountabilitymustbeestablishedforbothRoom2200and2300.Thefacilityheadcountmustagreewiththenumberofpersonssignedinontheaccountabilityforms.2.UsingAttachment2A,OSCEROShiftStaffingandAccountabilityRoster,initiatetheestablishmentofinitialfacilityaccountability.B.FACILITYOPERATIONNOTECertainpositionsassignedtotheOSCarenotnecessarilylocatedintheOSC,butforaccountabilitythesepersonsaretrackedwithOSCpersonnel.ThesepositionsarenottobeloggedasRe-entryTeamsortoappearontheAccountabilityRosterifthepersonshaveactuallyleftsite.1.Logthenamesandbadgenumbersofpersonsfillingthefollowingpositionsandmaintainaccountabilityforthemevenafterleavingthefacilityand/orsite:a.AssemblyAreaSupervisor:b.ControlRoomHPcoverage1~Unit1:2.Unit2:
REVISIONNO.:PROCEDURENO.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERPAGE:54of55EPIP-05ST.LUCIEPLANTATTACHMENT8OSCSECURITYCHECKLIST(Page2of3)B.(continued)INITIAL1~(continued)c.FieldMonitoringTeam-Red1~Driver:2.HP:d.FieldMonitoringTeam-Blue'I.Driver:2.HP:e.FieldMonitoringTeam-Orange1.Driver:2.HP:f.Other(e.g.,HPsenttooff-siteAssemblyArea,hospital,etc.):2.Establishinitialfacilitypersonnelaccountablerosterrequired30minutesfollowingevacuationofnon-essentialpersonnel.3.ReviseaccountabilitywhenNonLicensedOperatorsreporttotheOSCfollowingsiteevacuation.4.CoordinatewiththeAssemblyAreaSupervisortoestablishSecurityattheoff-siteAssemblyAreabasedonSecurityresourcesavailability.
REVISIONNo.:.5PROCEDURENo.:EPIP-05B.(continued)PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT8OSCSECURITYCHECKLIST(Page3of3)PAGE:55of55INITIAL5.Stepstooccurcontinuallywhilethefacilityisinoperation:a.AssisttheTSCSecuritySupervisorinmaintainingsiteaccountability.b.AssistRe-entryTeamsingainingaccesstoplantareas,asneeded.c.Assistoff-siteagenciesingainingplantaccess.d.AdvisetheOSCStaffofsecurityrelatedmatters.e.FollowSecurityProcedures.C.FACILITYCLOSEOUTANDRESTORATIONNOTEAIIpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheOSCSupervisor.2.Returnedpositionnotebooktostorageshelf./R5/R5 Title:FPLST.LUCIEPLANTEMERGENCYPLANIMPLEMENTINGPROCEDURESAFETYRELATEDProcedureNo.EPIP-06CurrentRev.No.3EffectiveDate:06/0t/00ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYResponsibleDepartment:RevisionSummaryEMERGENCYPLANNINGRevision3-THISPROCEDUREHASBEENCOMPLETELYREWRITTEN.AddednewPARbriefattachment.DeletednotificationandPARattachment(relocatedtonewEPIP-08.MovedresponsibilityforpreparingStateNotificationFormfromEOFHRDCommunicatortoEOFRMOpsAdvisor/Logkeeper.Addalternateinstructionforprocedurerevisionverification.Madeeditorialandadministrativechanges.AddedETMActivitiesListform.(DonnaCalabrese,05/31/00)O$DPSLCEOURFPftoDUCTIQNRevisionFRGReviewDate12/15/97RevisionFRGReviewDate05/30/00ApprovedByJ.ScarolaPlantGeneralManagerApprovedByR.G.WestPlantGeneralManagerApprovalDate12/15/97ApprovalDate05/31/00SOPSDATEDOCTPROCEDUREDOCNEPIP-06SYSCOMPCOMPLETEDITM3DesignatedApprover
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTTABLEOFCONTENTSPAGE:2of117SECTIONPAGE10PURPOSE~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
52.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTS.....~~..~..~~...~~~~~~73.0RESPONSIBILITIES.~......~~..~~~.~..~~....~~....~...~93.1RecoveryManager............~.3.2EOFEmergencyTechnicalManager.3.3EOFNuclearLicensingManager..~.3.4EOFHealthPhysicsManager....~.3.5EOFEmergencySecurityManager..3.6EOFAdministrativeSupervisor...~~3.7EOFRMOPSAdvisor/Logkeeper...3.8NuclearDivisionDutyOfficer3.9EmergencyControlOfficer.......~3.10GovernmentalAffairsManager~..~~3.11RiskManager3.12EPManager3.13EOFEmergencyInformationManager4.0DEFINITIONS~~~910111112121313~.13131414145.0INSTRUCTIONS........~....~.........ATTACHMENTS17ATTACHMENT1EOFEmergencyResponseOrganization.........19ATTACHMENT2RecoveryManagerChecklist...........ATTACHMENT2AEOFEROShiftStaffing.~..~..........2024ATTACHMENT2BATTACHMENT2CEOFStaffBriefing/UpdateAgenda~~~~~~~~~~25~27StateandCountyPARBriefingGuideline.....ATTACHMENT2DDe-escalationGuidelines.~..~~~...~.~....~..~29ATTACHMENT2ERecoveryPlanning30 REVISIONNo.:PROCEDURENo.:EPIP-06SECTIONPROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTTABLEOFCONTENTS(continued)PAGE:3of117PAGEATTACHMENTS(continued)ATTACHMENT3EOFRMOPSAdvisor/LogkeeperChecklist.......31ATlACHMENT3ATypicalInformationtobeincludedintheRMLogbook34ATTACHMENT4EOFEmergencyTechnicalManagerChecklist..~~.~35ATTACHMENT4AETMActivitiesList.~........................38ATTACHMENT5EOFProjectEngineerChecklist................39ATTACHMENT5AEngineeringTaskandTechnicalResponseForm...42ATTACHMENT5BEngineeringTaskList.~~....~..~~~.~.....~..43ATTACHMENT5CEngineeringShiftStaffingSchedule~......~.....44ATlACHMENT6EOFEngineerChecklist...~~~~~~~~~~~~~~~~45ATTACHMENT7EOFERDADSOperatorChecklist~.~.~...~~....47ATTACHMENT7AERDADSDataAcquisition................ATTACHMENT7BERDADSDataPoints4952ATTACHMENT8EOFStatusBoardKeeperChecklist.~.......ATTACHMENT9EOFNuclearLicensingManagerChecklist.....6062A1TACHMENT9ATypicalInformationtobeincludedintheLogbook...65ATTACHMENT10EOFCommunicatorChecklist....~~..~...~66ATTACHMENT10ACommunicationsGuidelines......~.~.~.70AlTACHMENT10BPlantDataSheet...........................78ATTACHMENT11CountyTechnicalAdvisorChecklist81 REVISIONNo.:PROCEDURENo.:EPIP-06SECTIONPROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTTABLEOFCONTENTS(continued)PAGE:4of117PAGEATTACHMENTS(continued)ATTACHMENT12EOFHealthPhysicsManagerChecklist83ATTACHMENT12ABasisforExposureLimitsforEmergencyResponsePersonnel~~~~~~~~~~~~~~~~~0~~~~~~~~~~~086ATTACHMENT13EOFDoseAssessor/FMTCoordChecklist89ATTACHMENT14EOFHPTechSupportChecklist.~~~~..~...~..~91ATTACHMENT15EOFRadStatusBoardKeeperChecklist......~..93ATTACHMENT16EOFAdministrativeSupervisorChecklist..........95ATTACHMENT17EOFAdministrativeStaffChecklist..............98ATTACHMENT17AEOFTelecopyLog.........~......~......~101ATTACHMENT18EOFEmergencySecurityManagerChecklist.....102ATTACHMENT18AInjuredPersonReport......................105ATTACHMENT19NuclearDivisionDutyOfficerChecklist..........106ATTACHMENT19ATypicalInformationtobeincludedintheECOLogbooke~~~~~~~~~~~'~~~~~~~~~~~~~~108ATTACHMENT20EmergencyControlOfficerChecklist............109ATTACHMENT21GovernmentalAffairsManagerChecklist..110ATTACHMENT22EmergencyInformationManagerChecklist.......112ATTACHMENT22ANewsBriefingGuidelines..~.~.~...~...~.~~..115ATTACHMENT23EIIVI/ENCTechnicalAdvisorChecklist....116 REVISIONNo.:3PROCEDURENo.:EPIP-061.0PURPOSEPROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:5of1171.1DiscussionThisprocedureprovidesinstructionsfortheactivationandoperationoftheEmergencyOperationsFacility(EOF).1.2LocationandDescriptionTheEOFisadedicatedfacilitylocatedattheintersectionofStateRoute712(MidwayRoad)andI-95approximately101/2mileswestoftheSt.LuciePlant.TheEOFhasemergencycommunicationsequipment,precalculatedemergencydata,pertinentreports,plans,procedures,anddrawingsavailableforuse.1.3EOFFunctionsAccidentassessmentinconjunctionwiththeTechnicalSupportCenter(TSC)2.Protectiveactiondecisionmaking3.Off-sitenotifications(State,County,NRC)4.Off-sitedoseassessment5.Off-sitefieldmonitoringactivities6.Coredamageassessment7.InterfacilitycommunicationswiththeTSC8.Interactionwithoff-siteofficials9.Directionofrecoveryoperations
REVISIONNO.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:6of1171.0PURPOSE(continued)1.4MinimumStaffing1~ThefollowingisarecommendedlistoftheminimumpositionsneededforEOFoperation:RecoveryManagerEOFRMOPSAdvisor/LogkeeperEOFCommunicator(HRD)ERDADSOperatorOREOFCommunicator(toTSC)EOFDoseAssessor/FMTCoordg,1.5ActivationActivationoftheEOFistheresponsibilityoftheRecoveryManager(RM)andisrequiredforaSiteAreaEmergencyorGeneralEmergency.EOFpersonnelshouldbeplacedinthefacilityforanAlert,asconditionswarrant.ArrangementshavebeenmadetoactivatetheEOFinatimelymanner.1.6OperationsTheEOFhassufficientspacetoaccommodatetheFloridaPower&LightCompany(FPL)responseorganizationanddesignatedrepresentativesoftheFederal,State,andLocalauthorities.Thisco-locationallowsforaneffectivecommunicationsinterface,coordinateddecisionmaking,andtimelyimplementationofprotectiveactions.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:7of11
72.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTSNOTEOneormoreofthefollowingsymbolsmaybeusedinthisprocedure:gIndicatesaRegulatorycommitmentmadebyTechnicalSpecifications,ConditionofLicense,Audit,LER,Bulletin,etc.,andshallNOTberevisedwithoutFacilityReviewGroupreviewandPlantGeneralManagerapproval.Indicatesamanagementdirective,vendorrecommendation,plantpracticeorothernon-regulatorycommitmentthatshouldNOTberevisedwithoutconsultationwiththeplantstaff.
2.1REFERENCES
1.St.LuciePlantTechnicalSpecificationsUnit1andUnit2(Section6.10.1)2.St.LuciePlantUpdatedFinalSafetyAnalysisReport(UFSAR)Unit1andUnit23.St.LuciePlantRadiologicalEmergencyPlan(E-Plan)4.St.L'uciePlantPhysicalSecurityPlan5.St.LuciePlantSafeguardsContingencyPlan6.St.LuciePlantTopicalQualityAssuranceReport7.E-PlanImplementingProcedures(EPIP00-13)8.St.LuciePlantEmergencyResponseDirectory(ERD)9.FloridaPower8LightCompanySt.LuciePlantRecoveryPlan10.FloridaPower&LightCompanyCorporateCommunicationsNuclearEmergencyPlan.11.QI-17-PSL-1,QualityAssuranceRecords
REVISIONNo.:,,3PROCEDURENo.EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:8of11
72.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTS(continued)
2.1REFERENCES
(continued)12.FitnessforDutyRule,10CFR2613.ReactorOperatorTechManual8770-1205814.NUREG-0654,Rev.1,FEMARep.1,CriteriaforPreparationandEvaluationofRadiologicalEmergencyResponsePlansandPreparednessinSupportofNuclearPowerPlants;November,1980.15.St.LucieUnit1and2as-builtdrawings,NuclearEngineeringfiles,andEbascoEngineeringfiles16.InstituteofNuclearPowerOperations,EmergencyResourcesManual-INPO86-032.%417.NuclearEnergyPolicyonExposureLimitsforEmergencyResponsePersonnel,RevisiontoPolicyStatement,Ltr.No.JNO-HP-94-056,26October,1994.2.2RECORDSREQUIRED1.Thefollowingshallberetainedfollowingaplantemergency:~Checklists,dataandpaperworkgeneratedperthisprocedure.~Logbooksmaintainedduringtheplantemergency.2.RecordedinformationshallbeforwardedtoEmergencyPlanningfollowingtheevent,forreviewandarchivalinaccordancewithTechnicalSpecification6.10.1andQI-17-PSL-1.2.3COMMITMENTDOCUMENTS1.ConditionReport96-2900,(ReviewandapprovalofRecoveryPlan)2.PMAI99-0-024(RMBriefingConsistency) t REVISIONNo.:3PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:9of1173.0RESPONSIBILITIES3.1RecoveryManager(RM)1~DeclarestheEOFoperationalforanySiteAreaEmergencyorGeneralEmergency.2.EstablishesandmaintainscommandandcontroloftheEOF.3.'ssumesthefollowingresponsibilitiesfromtheEmergencyCoordinator(EC)whentheEOFispreparedto'gooperational:A.Notificationofoff-siteagencies(StateandCounties),andB.DevelopsandissuesProtectiveActionRecommendations(PARs)toStateandCountyofficials.4.DeclarestheEOFoperationalwiththeconcurrencefromtheEC.5.EnsuresnotificationofStateand.Countyagenciesoccurswithinfifteen(15)minutesfollowinganychangeinemergencyclassificationandnotificationoftheNRCoccursimmediatelyfollowingnotificationoftheStateandCounties,andinallcaseswithinone(1)hour.6.Establishespolicies,forsituationsinwhichnocompanypolicycurrentlyexists,tosupporttheactionsthatwillaidinmitigationoftheemergency.7.Expendsfundsasnecessarytocopewithemergencysituations.8.ProvidessupporttotheECasnecessary.9.ProvidesconcurrencetotheECforexceeding10CFR20limitsforemergencyresponsepersonnel,asappropriate.
,
REVISIONNO.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:10of1173.0RESPONSIBILITIES(continued)3.1RecoveryManager(RM)(continued)10.Requestsadditionalsupportasnecessary.11.InterfaceswiththeNuclearRegulatoryCommission,DirectorofSiteOperations(NRC,DSO)whentheNRCSiteTeamarrivesattheEOF.12.De-escalatesalleventsclassifiedasSiteAreaEmergencyorGeneralEmergency.13.PreparesanIncidentReportforsubmittaltotheStateDivisionofEmergencyManagement(DEM)andtheNRCwithintwenty-four(24)hoursafterterminationofanAlertorhigheremergencyevent.3.2EOFEmergencyTechnicalManager(ETM)41~ProvidesengineeringsupporttotheEOFbydirectingallengineeringresponseincluding:A.NuclearEngineeringB.NuclearFuelsEngineeringandcoredamageanalysisC.ElectricalEngineeringD.I&CEngineeringE.MechanicalEngineeringF.CivilEngineering2.SupportstheTSCinproblemsolvingbasedonengineeringdesignandas-builtconstructiondetails.3.Overseesplantdataacquisitionandposting.4.InterfaceswiththeNRCReactorSafetyCoordinatorwhentheNRCSiteTeamarrivesattheEOF.
REVISIONNo.:3PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:11of1173.0RESPONSIBILITIES(continued)3.3EOFLicensingManager1~OverseesEOFcommunicationsperformedbythefollowingcommunicators:A.HotRingDown(HRD)CommunicatorB.EmergencyNotificationSystem(ENS)CommunicatorC.HealthPhysicsNetwork(HPN)CommunicatorD.TSCCommunicator2.EnsuresthattheInstituteofNuclearPowerOperations(INPO)iskeptabreastofemergencystatusandresourcerequirements.3.ServesasprimaryliaisonwiththeNRConcetheSiteTeamarrivesattheEOF,interfacingwiththeEmergencyResponseCoordinator.3.4EOF'ealthPhysicsManager(HPM)Directsthecollection,assessment,andinterpretationofallradiologicalandradiochemistryinformationintheEOF.2.AssiststheRMinPARdecisionmaking.3.Ensuresthatradiologicalquestions/concernsarisingfromtheEmergencyNewsCenter(ENC)areaddressed/resolved,4.InterfaceswiththeStateofFlorida'sDepartmentofHealth,BureauofRadiationControlonallradiologicalmatters.5.InterfaceswiththeProtectiveMeasuresCoordinatorwhentheNRCSiteTeamarrivesattheEOF.
REVISIONNo.:PROCEDURENo.PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:12of117EPIP-06ST.LUCIEPLANT3.0RESPONSIBILITIES(continued)3.5EOFEmergencySecurityManager(ESM)1~EstablishesfacilitysecurityandpersonnelIaccountabilitythroughouttheemergency.2.EnsurestherequirementsoftheFitnessforDutyrulearemetbypersonsreportingfordutyinEOFpositions.3.CoordinateswiththeTSCSecuritySupervisortosupportanyon-sitesecurityfunctionsandindeterminingtheneedtosuspendsafeguards.4.Providestheinterfacewithlocallawenforcementandrescueagencies.5.Tracksthestatusofallsitepersonneltransportedtooff-sitemedicalfacilities.6.InterfaceswiththeSafeguards/SecurityCoordinatorwhentheNRCSiteTeamarrivesattheEOF.3.6EOFAdministrativeSupervisor1.Overseesalladministrativeservicessuchas:CAUTIONDocuments,suchasinstructions,procedures,drawings,andsoftwarewhichprovideguidance,specifications,orrequirementsaffectingthequalityofsafety-relatedstructures,systems,andcomponents,shallbecontrolled.A.AvailabilityofcontrolleddocumentsB.ReproductionanddistributionservicesC.Supportfortelephoneandtelecopyoperations2.Makesarrangementsforlongtermfacilityoperationsincludingpersonnel,supplies,andequipment.
REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:13of117EPIP-06ST.LUCIEPLANT3.0RESPONSIBILITIES(continued)3.7EOFRMOPSAdvisor/Logkeeper1~AssiststheRMinallassignedresponsibilitiesincludingoff-sitenotificationsandProtectiveActionRecommendations(PARs).2.FulfillstheroleofRMinthe"bullpen"whentheRMisinconference.3.MaintainstheRMLogbookwhichservesastheprimaryfacilitylog.3.8NuclearDivisionDutyOfficer(NDDO)1.ThispositionisnotrequiredtobeintheEOF.2.Maintains24houradayon-callavailability.3.ServesasatechnicaladvisortotheEmergencyControlOfficer(ECO).4.PerformsthedutiesoftheECOifonecannotbelocated.5.EstablishesinitialcontactwithINPO.3.9EmergencyControlOfficer(ECO)i1.ActsasthechiefnuclearofficerintheabsenceofthePresidentoftheNuclearDivision.2.ServesastheofficialspokespersonfortheNuclearDivision.3.ApprovesallpressreleasesfortheNuclearDivision.3.10GovernmentalAffairs"Manager(GAM)1.ThispositionisnotrequiredtobeintheEOF.2.ProvidesliaisonfunctionbetweentheECOandpublicofficials.3.WorkswiththeGovernmentalAffairsRepresentative(GAR)andGovernor'sAdvisor.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:14of1173.0RESPONSIBILITIES(continued)3.11RiskManager1.ThispositionisnotrequiredtobeintheEOF.2.Providesliaisontothenuclearinsuranceindustry.3.12EPManager1~ThispositionisnotrequiredtobeintheEOF.2.ProvidesemergencypreparednessprogramexpertisetotheRMandotherEOFstaffasnecessary.3.13EOFEmergencyInformationManager(EIM)Delegatesresponsibilityforverbalandwrittencommunicationasneeded.2.DetermineswhenanemergencyisseriousenoughtoactivatetheCorporateCommunications(CC)NuclearEmergencyPlan(CCNEP),includinginitiatingnotificationsandcallingforadditionalcommunicationssupportasneeded.3.CallsfortheactivationofanEmergencyNewsCenter(ENC),afterconsultingwiththeECO.4.InvitesFederal,StateandCountypublicinformationofficerstorespondtoENCwhereinformationcanbejointlyprovidedtothenewsmedia.5.DeclarestheENCoperational,incoordinationwiththeENCManagerandECO.6.EnsuresthattechnicaladvisorsareassignedtotheCountyEmergencyOperationsCenters(EOCs)andthatcontactisestablished.
t REVISIONNO.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:15of1174.0DEFINITIONS4.1EmergencyPlanningZones:1.PlumeExposurePathway(10mileEPZ)-thatarea,approximately10milesinradiusfromthecenteroftheplant,forwhichdetailedplansaremadetoprotectpeoplefromexposuretoaplumecontainingradioactivematerials.2.IngestionExposurePathway(50mileEPZ)-thatarea,approximately50milesinradiusfromthecenteroftheplant,forwhichplansaremadetoprotectpeoplefromingestionoffood-stuffsandwatercontaminatedbyradioactivematerialsreleasedfromtheplant.4.2FacilityStatus:Activation-therequesttostaffandestablishanEmergencyResponseFacility(ERF).2.Operational-whensufficientpersonnel(i.e.,minimumstaff)areavailabletoaccomplishthemandatoryfacilityfunctionsofoff-sitenotificationsanddevelopmentofPARsANDtheRMhascompletedaturnoverwiththeECforassumptionofthesefunctions.3.FullyStaffed-thecompletecomplementofpersonnelispresentinthefacility.4.3FPLEmergencyRecallSystem(ERS)-thecall-outsystemusedasthemeansofoffhourscall-out,asdescribedinEPIP-03,EmergencyResponseOrganizationNotifications/StaffAugmentation.4.4ProtectiveActionsImplemented(PAls)-actualprotectiveactioninstructionsgiventothegeneralpublicbasedontheevaluation,byStateandCountyofficials,oftheProtectiveActionRecommendations(PARs)receivedfromFPL(i.e.,actualshelterand/orevacuationresponseactionstakenbythepublic).4.5RiskCounties-thosecountieslocatedwithinthe10mileEmergencyPlanningZoneofanuclearplant.ForSt.LuciePlant,theriskcountiesareSt.LucieandMartin.
REVISIONNo.:PROCEDURENO.EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:16of1174.0DEFINITIONS(continued)4.6StateAgencies:1.FloridaDivisionofEmergencyManagement(DEM)-headquarteredinTallahassee,responsiblefortheStateofFloridaRadiologicalEmergencyManagementPlanforNuclearPowerPlants.2.FloridaDepartmentofHealth(DOH),BureauofRadiationControl-headquarteredinOrlando,responsibleforradiologicalmonitoringanddoseassessment.4.7"Videolink"-aclosedcircuitaudio/visualcommunicationslinkoriginatingintheTSCwithfeedstotheOSCandtheEOFallowingtheECbriefingstobeavailableinalltheEmergencyResponseFacilities(ERFs).
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:17of1175.0INSTRUCTIONSNOTE~ThissectionprovidesgeneralinformationandinstructionsforallEOFresponders.~Positionspecificchecklistsareincludedasattachmentstothisprocedure.~IndividualsspecificallydesignatedasmembersoftheEOFEmergencyResponseOrganization(ERO)areidentifiedintheERD.5.1ReportwhennotifiedtotheEOFasquicklyaspossibleifavailableandabletosafelydoso.5.2Uponarrivalatthefacility,eachEOFemergencyrespondershouldperformthefollowing:1.PresentSecuritywithaformofpictureidentification.2.InformSecurityofyour"fitnessforduty"status.3.ObtainandwearapositionspecificaccessbadgeavailableintheSecurityareaasyouenterthebuilding.A.Placeyournameonthebadgewithadryerasemarkerorinanyothernon-permanentmanner.4.Sign-inontheStaffingBoardlocatedonthesouthwallofthe"bullpen"(room101).5.Obtainpositionspecificnotebookwithproceduralchecklists,formsandinstructions.6.Makeyourworkstation/locationoperational.7.Notifyyoursupervisorofyourreadinessstatus.NOTEOnlycontrolledcopiesofnuclearsafety-relatedprocedures,drawings,andotheravailableplantinformationshallbeused.Non-controlleddocumentsordrawingsshallbeverifiedwithacontrolledcopypriortouseintheEOF.5.3Communicationstotheplantshouldbemadethroughthephonetalkersand/ortheTSC.
REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:18of117EPIP-065.0INSTRUCTIONS(continued)ST.LUCIEPLANT5.4Duringfacilitybriefings,stopwhatyouaredoing,payattentionandcontributeasrequested.5.5Uponterminationoftheevent:1.AllEOFpersonnelshouldreturntheirworkstations/locationstoanormalstateandassistinrestoringthefacilitytoareadycondition.2.Collectallsignificantinformationanddocumentation,suchascompletedEPIPsandattachments,logs,notificationformsandothernotesanddatasheets,andforwardthismaterialtoEmergencyPlanning.
REVISIONNOJ3PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT1EOFEMERGENCYRESPONSEORGANIZATION(Page1of1)PAGE:19of117POCUCOl~OOEoo>0Qa~ZQ~oo(oO.CUQn.,Q8Q(',SUJETcv~OIOI+OCEoQJ<<IUQCUJ<<oPCCUOoIUIUCO~ICUCUOILCCOXCU3.ODQ6O~UIIUPoC)ILOjLJ1IILRO$K(sLJg$ILILILOooUlIUIU0QcSROOILUILILILOooooUlUlUlIUIU REVISIONNo.:PROCEDURENo.EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT2RECOVERYMANAGERCHECKLIST(Page1of4)PAGE:20of117CAUTIONThemandatoryfunctionoftheEOFistoassumeresponsibilityformakingnotificationsandPARs.TheRMshouldassumethisresponsibilityassoonaspracticable,butnotbeforetheEOFstaffisfullypreparedtodoso.NOTE,Whennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.'ACILITYACTIVATIONINITIAL1~Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.Determineifminimumstaffisavailable(refertoAttachment2A,EOFEmergencyResponseOrganizationandShiftStaffing).3.DeterminefromtheOpsAdvisorthatEOFcommunicationsareavailable.4.NotifytheECoftheEOF'sreadinesstotakeresponsibilityforoff-sitenotifications(State,CountiesandNRC)andPARs.5.BasedonconcurrencefromtheEC,declareEOFoperational(steps384mustbecompleted).Operationalat0 REVISIONNo.:3PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT2RECOVERYMANAGERCHECKLIST(Page2of4)PAGE:21of117A.FACILITYACTIVATION(continued)6.NotifythefollowingthattheEOFisoperational:a.ECb.EOFstaffc.Stateandlocalauthoritiesd.NRCe.ECOINITIAL7.RequestthatallfacilityclocksbesynchronizedwithERDADS.IncaseofERDADSfailure,synchronizewiththeaffectedControlRoom.8.EOFfullystaffed.B.FACILITYOPERATION1~Establishbriefingfrequencyforfacilityupdates.2.DirectanRMOPSAdvisor/LogkeepertokeepLogbook.3.Stepstooccurcontinuallywhilethefacilityisinoperation:a.Off-sitenotificationsforbothState/CountyandtheNRCareapprovedandprovidedinatimelymannerandinaccordancewithEPIP-08,Off-siteNotificationsandProtectiveActionRecommendations.b.Develop/adjustandapprovePARs,asnecessaryinaccordancewithEPIP-08andwiththeassistanceoftheEOFRMOPSAdvisor/LogkeeperandtheEOFHPManager.c.ProvidePARBriefingstoStateandCountypersonnelinttIeEOFwiththeassistanceoftheEOFRMOPSAdvisor/LogkeeperandEOFHPManagerandusingAttachment2C,StateandCountyPARBriefingGuideline.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT2RECOVERYMANAGERCHECKLIST(Page3of4)PAGE:22of117B.FACILITYOPERATION(continued)3.(continued)CAUTIONTheRMshallnotdelegatethefollowing:~StateNotificationFormapproval~RecommendationofProtectiveActions~ExpenditureofFunds~PolicySettingd.RequestanRMOPSAdvisor/Logkeeperactastemporaryreliefwhenleavingthe"BullPen"~e.EnsurethatProtectiveActionsImplemented(PAls)arepostedintheEOFandreportedtotheEC.f.Maintainfacilitycommandandcontrol.g.Conductfacilitybriefings(useAttachment2Btothisattachment).h.ContacttheECfrequentlytomaintainawarenessofplantconditionsandactions,(The"Videolinkmaybeusedforthispurpose.)i~Providesupport/resourcestotheECfromotherFPLsources,nuclearpowerplantsand/orvendors.j.ReviewemergencydoseextensionswiththeEC(useAttachment12A,BasisforExposureLimitsforEmergencyResponsePersonnel.k.Requestadditionalsupportasnecessary.I.RoutinelyreviewstatuswiththeECO.m.Establishpolicieswhensituationsarisewherenocompanypolicyisinplacetosupporttheactionsthatwillaidinmitigationoftheemergency.
REVISIONNo.:3PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT2RECOVERYMANAGERCHECKLIST(Page4of4)PAGE:23of117B.FACILITYOPERATION(continued)3.(continued)n.Expendfundsasnecessarytocopewithemergencysituations.(SolicitauthorizationfromthePresidentNuclearDivision)o.InterfacewiththeNRCDirectorofSiteOperations(DSO)andothermembersoftheSiteTeam,asrequired.4.DirecttheEOFAdministrativeSupervisortoestablishthecapabilityfor24houroperationoftheEOF.g,5.De-escalatetheemergencyclassificationtoSiteAreaEmergencyorlowerclass(useAttachment2D,De-escalationGuidelines).6.Initiatetherecoveryplans(useAttachment2E,RecoveryPlanning).C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.g,1.DirectLicensingtopreparetheIncidentReportforsubmittaltoDEMandNRC(within24hoursafterterminationofanAlertorhigheremergencyevent).2.Allfacilityactivitiesclosedout.3.Allpaperworkcollected.4.Allequipmentandsuppliesreturnedtopre-activationconditionand/orlocation.5.ProvidedallcompletedpaperworktoEmergencyPlanning.
REVISIONNO.:PROCEDURENO.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:24of117EPIP-06ST.LUCIEPLANTATTACHMENT2AEOFEROSHIFTSTAFFING(Page1of1)SHIFT:'RECOVERYMANAGER'OpsAdvisorHPManagerEmergencyTechnicalManagerOpsAdvisorNuclearLicensingManager'EOFCommunicator(HRD)EOFCommunicator(ENS)HPTechSupport'DoseAssessor/FMTCoordDoseAssessor/FMTCoordDoseAssessor/FMTCoordProjectEngNudearEngl&CEngCivilEngEOFCommunicator(HPN)'EOFCommunicator(TSC)RadStatusBrdKprAdminSupervisorMechanicalEngMechanicalEngAdminStaffAdminStaffNucFuelsEngElectricalEng"EPManagerAdminStaffEMERGENCYCONTROLOFFICEREmergencyInfo.Manager"NuclearDivisionDutyOfficer-RiskManagerENCManagerEIM/ENCTechAdvPlantStatusBrdKpr'ERDADSOper"Gov.AffairsManagerEIM/ENCTechAdv'*Gov.Adv-TallahasseeSt.LuciaCountyTechAdv"Gov.AffairsAsstMartinCountyTechAdvCorpComm/ENCStaffEmergencySecurityManager*RecommendedMinimumStaffing*'ptionalStaffing(nottypicallyEOFresponders)Acceptablealternatesforrecommendedminimumstaffing:RecoveryManager-DesignatedalternatesinERD.RMOPS.Advisor-Anyresponderwithactiveorpastoperatinglicensoorequivalent(RO,SRO,SROCert)atPSLorPTN.HRDCommunicator-AnyresponderERDADSOperator-AnyrosponderwithworkingfamiliaritywithERDADscomputerTSCCommunicator-AnyresponderwithplanttechnicalbackgroundDoseAssessmentCoordinator-Anyrespondertrainedinradiologicalassessment.
REVISIONNo.:3PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT28EOFSTAFFBRIEFING/UPDATEAGENDA(Page1of2)TIME:PAGE:25of117NOTE1.Updatesshouldoccurapproximatelyevery30minutes.Significantchangesineventsshouldbeannouncedpromptly.2.Briefingsshouldnotexceed10minutes.3.ReferenceinRMLogandretainforarchival.EmergencyClassification:Unit1Status:Unit2Status:CurrentInformation:NOTETakethetimenecessarytoexplaineventsattheplant.1.Classificationchanges2.Radiologicalreleaseoccurrenceortermination(thisincludessignificantchangesinsourcetermormeteorologicaldata)3.Lossorrestorationofsignificantequipmentand/orsystem,suchaslossofmake-upcapability,containmentfailure,etc.4.ChangestoPARsortoProtectiveActionsImplemented(PAls)5.Injured/ContaminatedPersonnel6.Currentmission(s)ofEOF,assigntask(s),asnecessary.
REVISIONNO.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT2BEOFSTAFFBRIEFING/UPDATEAGENDA(Page2of2)PAGE:26of117OtherInformation(Requestinput/updateinformationfromotherrepresentatives.Remindcontributorstobebriefandlimitcommentstosignificantnewinformation.)HealthPhysicsRepresentative:2.EngineeringRepresentative:3.SecurityRepresentative:4.StateRepresentative:A.DEM:B.DOH:5.St.LucieCountyRepresentative:6.MartinCountyRepresentative:7.NRCRepresentative:
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATT'CHMENTT2CSTATEANDCOUNTYPARBRIEFINGGUIDELINE(Page1of2)PAGE:27of117ThefollowinginformationshouldbeprovidedtorepresentativesfromtheStateofFloridaandSt.LucieandMartinCountiesduringeachPARbriefing.Followinginitialreviewanddiscussion,theOPSAdvisor,HPManager,andothersasneededshouldremaintoansweranytechnicalquestionsortoprovideadditionalclarification.1.AffectedUnit(s):PSL12.CurrentEmergencyClassification:PSL2BothUnits3.Timewhenthecurrentemergencyclassificationwasmade:4.Reasonfortheemergencydeclaration(inlayman'sterms):5.ReleaseStatus:None/Occurred,butStopped/IsOccurringIfareleaseisOccurring,thenisit?WithinNormalOperatingLimitsNon-significantfractionofPAGrangePAGrange(protectiveactionsrequired)6.Weather:WindDirection(from)SectorsAffected7.StatusofReactor:Shutdown/CoreAdequatelyCooled/FuelCladdingIntact8.ElectricalPowerAvailable:YeaNo
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT2CSTATEANDCOUNTYPARBRIEFINGGUIDELINE(Page2of2)PAGE:28of1179.AffectedReactor(s)CoreCondition:GettingBetter/NoChange/Worsening10.RelevantPlantEquipmentIssues(ifany):11.ProtectiveActionRecommendations:Miles0-22-55-10NoActionEvacuateSectorsShelterSectorsProtectiveActions-Implementation1.TheStateandCountieswilldetermineresultingprotectiveactionstoimplement.2.AssoonaspracticalafterthebriefingofanyPARstotheStateandCounties,theRMshallconsultwithDEMandCountyrepresentativesintheEOFconcerningtheactualProtectiveActionsImplemented(PAls)~3.Whennotified,recordtheresults(using"areas")onthePARWorksheet.4.RequestthattheGovernor'sAuthorizedRepresentative(GAR)announcetheProtectiveActionsImplementedtotheEOFstaff(theRMshouldmaketheannouncementiftheGARisunavailable).5.NotifytheECofthePAIs.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT2DDE-ESCALATIONGUIDELINES(Page1of1)PAGE:29of117Thefollowingguidelinesprovidepointstoconsiderwhende-escalationmaybeappropriate.1.ReviewtheEmergencyClassificationTablesinEPIP-01withtheEmergencyCoordinatortoassurethattheclassificationcriteriatoentertheeventarenolongerapplicable.2.Verifyadditionallythattheplantisstable,undercontrol,andtrendorprognosisindicatesthatimprovementisthemostlikelyprospect.Considerthefollowing:a.Subcriticalityb.CoreCoolingModec.HeatSinkModed.RCSPressureBoundaryIntegritye.InventoryControl(PrimaryandSecondaryCoolant)3.Verifythereisnoforeseeablelikelihoodofasignificantuncontrolledrelease.Considercontainmentpressure,containment/auxiliarybuildingradiationlevels,wastegasstoragetankpressuresandactivities,andcontainmentwatervolumesandactivities.4.Verifythatthelong-termstaffingforboththesiteandtheEOFisorganizedandinplaceasappropriatefortheevent.NOTEDe-escalationoftheeventdoesnotmeanthatprotectiveactionsforthegeneralpublicwouldterminate.ThisissueshouldbeaddressedseparatelyandspecialattentionshouldbegivenviatheENCtoensurethatpublicinformationchannelsareawareofthedifference.g25.VerifythattheEmergencyCoordinator,EmergencyControlOfficer,DEMGovernor'sAuthorizedRepresentative,CountyEmergencyManagementDirectorsandtheNRCareinformedthatde-escalationoftheemergencyclassificationisinorder.
REVISIONNO.:3PROCEDURENo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:30of117EPIP-06ST.LUCIEPLANTATTACHMENT2ERECOVERYPLANNING(Page1of1)NOTETheFloridaPower8LightCompanySt.LuciePlantRecoveryPlanandotherFPLcompanyplansmaybereferencedasguidancetoassistintheorganizationofrecoveryactivities.A.Formulategeneralplansforrecoveryoperationsusingatypicaloutagemanagement/workcontrolformatandincludingthefollowingadditionalconsiderations:1.Identificationoforganization,personnel,andfacilitiestobeusedinrecoveryoperations.a.PortionsoftheEROcontinuetofunctionduringrecoveryoperationsincludingleademergencyresponsemanagers:1.EC/PlantGeneralManager2.RM/SiteVicePresidentb.Emergencyresponsefacilities(TSC,OSC,EOF)maybeusedforrecoveryactivities.2.Identificationofexternal(FPLandindustry)assistanceforinclusionintherecoveryorganization.3.IdentificationofinterfacesbetweenFPLorganizations,off-siteemergencyauthorities,regulatoryagencies,andotherapplicableorganizations.4.IdentificationofinterfacesbetweenFPLandthenewsmedia.a'.CorporateCommunicationsorganizationusedduringtheemergencymayremaininplace,ifdeemedappropriate.
REVISIONNo.:3PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT3EOFRMOPSADVISOR/LOGKEEPERCHECKLIST(Page1of3)PAGE:31of117NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.AssisttheRMindeclaringtheEOFoperationalbyverifyingthefollowing:a.Minimumstaffavailableb.Communicationsequipment,proceduresandothersuppliesareavailable,checkedandreadyforuse.CommercialphoneasbackuptoState/CountyandNRCNotifications(DONOTtestcallHRDorENS).ExtensionphonesinEOF.EOFpersonnelareverifyingproceduresinpositionnotebooks.c.Minimumstaffpreparedtoaccomplishmandatoryfacilityfunctionsd.ECturnovercompletedB.FACILITYOPERATION1.InitiatetheRMLogbook(useAttachment3A,TypicalInformationtobeIncludedintheRMLogbook).2.ReviewAttachment2,RecoveryManagerChecklist.
REVISIONNO.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT3EOFRMOPSADVISOR/LOGKEEPERCHECKLIST(Page2of3)PAGE:32of117B.FACILITYOPERATION(continued)3.Stepstooccurcontinuallywhilethefacilityisinoperation:a.RoutinelyreviewEmergencyOperatingProcedures(EOPs)progresswiththeRMb.ContinuetolookaheadatpossibleemergencyclassificationsandPARsc.MaintaintheRMLogbookd.AssisttheRMincompletingtheStateNotificationFormanddevelopingPARs(useEPIP-08,Off-siteNotificationsandProtectiveActionRecommendations)CAUTIONResponsibilitiesnotdelegablebytheRM:~StateNotificationFormapproval~RecommendationofProtectiveActions~ExpenditureofFunds~Policysettinge.TemporarilyrelievetheRMinthe"BullPen"whenRMisinconferencef.SupporttheRMasneededorrequestedg.ProvideoperationsstatusduringPARbriefingsh.ServeasanalternateinterfacetotheNRCDSOandothermembersoftheNRCSiteTeam REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT3EOFRMOPSADVISOR/LOGKEEPERCHECKLIST(Page3of3)PAGE:33of117C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.Ensuredallfacilityactivitiesclosedout.2.Ensuredallpaperworkcollected.3.ClosedouttheRMLog,returnedthelogbooktotheRMpositionnotebook.4.ReturnedpositionnotebooktoRMoffice.5.ProvidedallcompletedpaperworktoEmergencyPlanning.
REVISIONNo.:3PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:34of117ATTACHMENT3ATYPICALINFORMATIONTOBEINCLUDEDINTHERMLOGBOOK(Page1of1)Maintainingconcise,detailedlogsduringanemergencyeventisimportant.Followingtheevent,allinformationrecordedwillbeneededtoprovideaclearpictureofactionstaken.A.ThefollowinginformationshouldbeincludedintheRMLogbook:1.Timeofeachentry.2.Emergencyclassificationchanges.3.Notablechangesinplantconditions.4.ProtectiveActionRecommendationsandProtectiveActionsImplemented.5.Summaryofanydirectionsgiventootheremergencyresponders(whowastoldwhattodowhen).6.Summaryofdiscussions/updateswithFederal,StateandLocalagencies.7.Summaryofdiscussions/updateswithEmergencyManagers.8.Adetailedexplanationofchangestoorestablishmentofnewcompanypolicy(s).9.Significantinformation,eventsandactionstakenrelativetotheemergencyperiodshouldberecorded.B.Logentryrequirements:1.Timeofentry.2.Useink.3.Write/printlegibly.4.Useconciseandaccuratewording.5.Strikethroughandinitialchanges.6.Donotremovepagesfromlogbook.
REVISIONNo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPROCEDURENo.:EPIP-06(Page1of3)ST.LUCIEPLANTATTACHMENT4EOFEMERGENCYTECHNICALMANAGERCHECKLISTPAGE:35of117NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATION11.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.Verifythatthefollowingpositionsarefilled:a.EOFERDADSOperator(minimumstaff)b.EOFNucFuelsEngineerc.EOFElectricalEngineerd.EOFProjectEngineere.EOFNuclearEngineerf.EOFl8CEngineerg.EOFCivilEngineerh.EOFMechEngineeri.EOFMechEngineerj~EOFStatusBoardKeeperINITIAL
PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYREVISIONNO.:PROCEDURENO.:EPIP-06ST.LUCIEPLANTATTACHMENT4EOFEMERGENCYTECHNICALMANAGERCHECKLIST(Page2of3)PAGE:36of117B.FACILITYOPERATIONINITIAL1.InitiatetheEngineeringLogbook.2.ObtainSystemavailabilitystatusfromSystemOperations.3.Stepstooccurcontinuallywhilethefacilityisinoperation:a.ReviewneedforengineeringsupportwiththeRM.b.Logrequestsforengineeringsupport.c.AssignengineeringtasksthroughtheEOFProjectEngineer.d.ParticipateinfacilitybriefingsconductedbytheRMbyprovidingstatusofengineeringissuesandprogressoftechnicalassistance.TheformprovidedinAttachment4A,ETMActivitiesListmaybeusedtoorganizebriefinginformation.e.Ensureplantparameterandsequenceofeventsdataaremaintainedcurrentandarecorrect/reasonable.f.ManageengineeringactivitiesinsupportoftheTSC.g.Reviewtheredundancyofcriticalplantequipment.h.Evaluatethelongtermplantactionstomitigatetheconsequencesoftheevent.i.InterfacewiththeEOFHealthPhysicsManagertoresolveissuesinvolvingplantcomponentseffectingplantreleases.j.SupporttheRMduringPARBriefingstotheStateandCounties.
REVISIONNo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPROCEDURENo.:EPIP-06ST.LUCIEPLANTATTACHMENT4EOFEMERGENCYTECHNICALMANAGERCHECKLIST(Page3of3)B.FACILITYOPERATION(continued)3.(continued)k.InterfacewiththeNRCReactorSafetyCoordinatorwhentheNRCSiteTeamarrivesattheEOF.PAGE:37of117INITIALI.PromptlyinformtheRMofengineeringrecommendations,determinations,oranalysisresults.m.SupportrecoveryplanningasrequestedbytheRMbyevaluatinglong-termplantactionstomitigatetheconsequencesoftheevent.C.FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.Allengineeringtasks/projectsarecompletedorassignedtoaConditionReport.r2.Allengineeringpaperworkiscollected.3.Alldocuments,equipment,andsuppliesreturnedtopre-activationconditionand/orlocation.4.ClosedouttheEngineeringLogbook.5.ReturnedpositionnotebooktotheRMoffice.6.ProvidedallcompletedpaperworktotheRM.
REVISIONNO.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT4AETMACTIVITIESLISTPAGE:38of1170'DcEEOKI-illOlODCdOClEI5JlOQ.C0CLIOEOClOEOQ.
REVISIONNO.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT5EOFPROJECTENGINEERCHECKLIST(Page1of3)PAGE:39of117NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.NotifytheETMwhenfullengineeringcomplement(aslistedbelow)isavailable:a.EOFERDADSOperatorb.EOFNucFuelsEngineerc.EOFElectricalEngineerd.EOFNuclearEngineere.EOFIBCEngineerf.EOFCivilEngineerg.EOFMechEngineer(2)h.EOFStatusBoardKeeper3.Assignthefollowingset-upitemstotheEngineeringStaff:a.SynchronizeclocksintheEngineeringareawithERDADS.IncaseofERDADSfailure,synchronizewiththeaffectedControlRoom.b.Obtainpens,pencils,paperandothernecessarysuppliesfromtheAdministrationarea.
REVISIONNO.:PROCEDURENo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYEPIP-06ST.LUCIEPLANTATTACHMENT5EOFPROJECTENGINEERCHECKLIST(Page2of3)B.FACILITYOPERATION1.Stepstooccurcontinuallywhilethefacilityisinoperation:a.ReviewrequestsforEngineeringSupport(useAttachment5A,EngineeringTaskandTechnicalResponseForm)withtheETM.b.Assignengineeringtasks.c.EnterengineeringtaskassignmentsonAttachment5B,EngineeringTaskList.d.Overseeprogressonassignedengineeringtaskse.Posttasks/projectsbeingworkedandstatusonstatusboardinETMoffice.f.Reviewcompletedworkforaccuracy.g.Filecompletedtasksheets(Attachment5A,EngineeringTaskandTechnicalResponseForm).h.ServeasalternateinterfacetoNRCReactorSafetyCoordinator.i.PromptlyinformtheETMofengineeringrecommendations,determinationsorresultsofanalyses.j.ProvideacopyofthecurrentAttachment5B,EngineeringTaskList,totheETMforfacilitystatusmeetings/briefings.k.SupporttheEOFETMinestablishing24-hourstaffingbycompletingAttachment5C,EngineeringShiftStaffingScheduleandprovideacopyofthecompletedformtotheEOFAdministrativeSupervisor.
REVISIONNO.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT5EOFPROJECTENGINEERCHECKLIST(Page3of3)PAGE:41of117C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.Identifiedallengineeringtasks/projectstotheETMforfinalaction(s).2.Supportedrestorationofalldocuments,equipment,andsuppliestopre-activationconditionand/orlocation.3.ReturnedpositionnotebooktotheRMoffice.4.ProvidedallcompletedpaperworktotheETM.
REVISIONNo.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:42of117TO:ATTACHMENT5AENGINEERINGTASKANDTECHNICALRESPONSEFORM(Page1of1)PRIORITY:123NO:
SUBJECT:
DATE&TIMERECEIVED:REQUEST:REQUESTER:RESPONSE:BY:VERIFIED:PROJECTS:EMERGENCYTECHNICALMANAGER:DATE8.TIME:
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT58ENGINEERINGTASKLIST(Page1of1)PAGE:43of117To:RecoveryManagerFrom:EmergencyTechnicalManager-Date:~~Time:TASKNO.TaskTitle:UNITPRIORITYDATE8(TIMENO.COMPLETEAssignedTo:TaskTitle:AssignedTo:TaskTitle:AssignedTo:TaskTitle:AssignedTo:TaskTitle:AssignedTo:
REVISIONNO.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT5CENGINEERINGSHIFTSTAFFINGSCHEDULE'Page1of1)PAGE:44of117EmergencyTechnicalManagerApproved:SHIFT1TimetoTimeSHIFT2SHIFT3toTimetoEmergencyTech.Mgr.EOFPh¹ProjectsEOFPh¹DatetoDatetoDatePlantStatusBoardEOFPh¹NuclearEOFPh¹MechanicalEOFPh¹ElectricalEOFPh¹l8CEOFPh¹CivilEOFPh¹FuelsEOFPh¹OtherEOFPh¹ REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT6EOFENGINEERCHECKLIST(Page1of2)PAGE:45of117NOTE1.Thischecklistappliestothefollowingpositions:EOFNuclearEngineerEOFMechanicalEngineerEOFl&CEngineerEOFNuclearFuelsEngineerEOFCivilEngineerEOFElectricalEngineer2.Whennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1~Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.IdentifyavailabilitytotheEOFProjectEngineer.B.FACILITYOPERATION1.Stepstooccurcontinuallywhilethefacilityisinoperation:a.WorktasksassignedbytheEOFETMorEOFProjectEngineer.b.ConferwithotherEOFpersonnelasneededtocompleteproblemresolutions.c.(NuclearFuels)performcoredamageassessmentinaccordancewithEPIP-11,CoreDamageAssessment.d.(NuclearFuels)providecoredamageassessmentresultstotheEOFETMandEOFHealthPhysicsManager.e.(NuclearFuels)SupportSevereAccidentManagementGuidelinesevaluationsbeingconductedintheTechnicalSupportCenter(TSC).f.KeeptheEOFProjectEngineerappraisedofstatusofworkingtasks/projects.
I, REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:46of117EPIP-06ST.LUCIEPLANTATTACHMENT6EOFENGINEERCHECKLIST(Page2of2)B.FACILITYOPERATION(continued)INITIAL1~(continued)g.Documentassessment/reviewandrecommendation/responseonAttachment5A,EngineeringTaskandTechnicalResponseForm,foreachtask/project.h.Evaluatepostedplantparameterdataforaccuracy.i.Ensuresequenceofeventsboardhassufficientdetailtounderstandeventsinprogress.C.FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1~Completedallassignedtasks,asappropriate.2.Returnedalldocuments,equipment,andsuppliestopre-activationconditionand/orlocation.3.ReturnedpositionnotebooktotheRMoffice.4.ProvidedallcompletedpaperworktotheEOFProjectEngineer.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT7EOFERDADSOPERATORCHECKLIST(Page1of2)PAGE:47of117NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.IdentifyavailabilitytotheEOFProjectEngineer.B.FACILITYOPERATIONCAUTIONEnsuredataisbeingcollectedfortheaffectedunit.EachunithaspredesignatedERDADSterminals,oneintheengineeringareaandoneinthedoseassessmentarea.1.CheckoutERDADSterminalsanddetermineoperabilitystatus.IfERDADSisinoperableorprintoutsarenotavailable,Then:a.AssisttheEOFCommunicator(toTSC)incollectingplantparameterandradiologicaldatabycompletingAttachment11(PlantDataSheetandRadioactiveGaseousSourceTerms).b.ContactTSCERDADSTechtoreporttheproblem.
REVISIONNO.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT7EOFERDADSOPERATORCHECKLIST(Page2of2)PAGE:48of117B.FACILITYOPERATION(continued)2.Stepstooccurcontinuallywhilethefacilityisinoperation:a.GallupEPIPscreensandadditionaldataasrequested,refertoAttachment7A,ERDADSDataAcquisition.b.ProvidethefollowingprintoutstotheEOFAdministrativeStaff:INITIAL1.St.LucieEOFDataSheet(EF1/2).2.RadioactiveGaseousSourceTerms(RG1/2).3.Otherscreens,asrequested.c.SupportdoseassessmentbyprovidingrequesteddatafromERDADS.d.ObserveERDADSdataduringintervalbetweenreportprintingforsignificantchangesandtrends,reportchangestotheEOFETManddoseassessment,asappropriate.e.RefertoAttachment7B,ERDADSDataPoints,tothisattachmentforadescriptionofERDADdatapoints.C.FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.ERDADSsystemreturnedtopre-activationconditionpertheinstructionsontheterminal.2.ReturnedpositionnotebooktotheRMoffice.
REVISIONNO.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT7AERDADSDATAACQUISITION(Page1of3)PAGE:49of117I~DATAACQUISITIONA.ERDADS-EmergencyResponseDataAcquisitionandDisplaySystem,thefollowinginformationisavailableonthedisplayscreensindicated.1.MeteorologicalData-Display:SMD(SiteMeteorologicalData)2.PlantParameterData-CAUTIONCertainparameters(e.g.,fanstatus)availableonUnit2areNOTavailableonUnit1.Display:intheEOF-EF(1/2)(SafetyFunctionsandEquipmentStatus)3.RadiologicalData-Display:RG(1/2)(RadiationGaseousSourceTerm)RBS(HealthPhysicsEvaluationScreen-containmentradiationlevelsandtrends)R11(AreaRadiationMonitors,Unit1)R21(AreaRadiationMonitors,Unit2)4.ChemistryData-Display:R12(S/GBlowdown,SteamJetAirEjector,Unit1)R22(S/GBlowdown,SteamJetAirEjector,Unit2)
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT7AERDADSDATAACQUISITION(Page2of3)PAGE:50of117I~DATAACQUISITION(continued)A.(continued)5.Toaccessdata-1-Press"CLEAR"2-Typein"PupUnit(1/2)"3-Press"EXEC"ute,topofscreenwillread"Unitchangeiscomplete"or"CurrentUnitissameasenteredUnit"4-Press"EPIP"5-The"PAGEUP"and"PAGEDOWN"keyswillcausethefollowingdisplaysequence:SMD-RG(1/2)-SF(1/2)-RBS-EF(1/2)-SMD6.Togodirectlytoascreen-1-Press"CLEAR"2-Typeinscreendesignation,e.g.,"RG1"3-Press"DISPLAY"B.TSCCommunicator-TheTSCCommunicatorcanbeutilizedasaprimarysourceofinformationorasanalternatemethodtoERDADS.1.Primarysource-statusoffansneededfordoseassessment:allfansforUnit1;fans6,7,8,15,16,and17forUnit2.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT7AERDADSDATAACQUISITION(Page3of3)PAGE:51of117II~ERDADS-COLOR/SYMBOLCONVENTIONS~GI/SNumericvalueinwhiteondarkgreenbackgroundNumericvalueblinking(yellowonblue/redonwhite)"BAD"(blueonwhite)"FAILED""NODATA"~EDataValueisvalidandwithintheinstrumentrangeValuemaybeyellowonbluebackground(urgentalarm)orredonwhitebackground(criticalalarm),indicatesanalarmsettinghasbeenexceeded,thealarmmustbeacknowledgedintheControlRoom(operatorsareunabletoacknowledgeERDADSalarmsintheSimulatorControlRoom),thevaluewillcontinuetoblinkuntilacknowledged;thevaluewillcontinuetoupdatePrecededbyanumericvalueinwhiteonabluebackgroundsignifyingasuspectvalueindicatingthatoneorseveralinputstothiscompositepointis/areoutofinstrumentrange,whenallinputstothepointareoutofrangetheword"BAD"replacesthenumericvaluePointisfromasingleinstrumentandthevalueisoutofrangePointdoesnothaveinputtoERDADS,usuallypointavailableononeunit,butnottheother'BasedonTable4.1intheERDADSReactorOperator'sManual(8770-12058)
REVISIONNO.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT7BERDADSDATAPOINTS(Page1of8)PAGE:52of117ThefollowingdatapointdescriptionsforSt.LuciePlantcorrespondwiththedatanormallytrackedontheplantparametersstatusboard.ConsultERDADSManual,asnecessary,forverificationofpointIDs,pointnamesordescriptioninformation.POINTDESCRIPTIONPTIDAvg.RCSTHotQTA541-1/2(HLAandHLB)(deg.F)POINTNAMETYPECALCULATIONAverageNOTESThisparameteristheaverageofthe'A'nd'B'teamgeneratorinlettemperature.Itisalsoreferredtoastheaveragehotlegtemperature.Theindividual'A'nd'B'otlegtemperaturesarederivedbychoosingbetweencurrentnarrowandwiderangesensorvalues.Thechoicedependsonthecurrentvalues,qualities,anddirectionoftheratesofchangeoftheinstrumentationvalues,aswellastwopairsofoverlappingswitchinglimitsandthemostrecentrangeutilized.Theoutputsfromthecalculationconsistofthechoiceofrange,theassociatedvalue,andrateofchangetogetherwiththequalityofeach.RCSPressureWR(psia)QA0501-1/2RcsPressureAverageThisparameterisaReactorCoolantSystem(RCS)widerangeinstrument.ItderivedfromPressurizerPressuresignalsPT1107-2andPT1108-2whicharelinear.Thesesignalsareprocessedbyan,averagewithexpandedqualityalgorithm.Thisfunctionobtainstheaverageofallvalueswithagoodstatus.Italsosetsthequalityoftheresultbasedonthenumberofvalueswithgoodstatus,versusthetotalnumberofinputs.Thepossiblestatusvaluesare:Greaterthan50%ofInputshavegoodstatus,resultisgood.OnlyonegoodvalueandthetotalInputsare3ormore,theresultIspoor.Whentherearenogooddatavalues,buttherearesomewithpoororsuspect,theresultispoof.Theresultissuspectforallothercasesexceptallbad,inthiscasetheresultisbad.
REVISIONNO.:PROCEDURENO.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:53Of117EPIP-06ST.LUCIEPLANTATTACHMENT7BERDADSDATAPOINTS(Page2Of8)POINTDESCRIPTIONPTIDPOINTNAMETYPECALCULATIONNOTESRCSPressurizerQA0001-1/2Level(%)PRZRLVLAverageThisparameterispressurizerlevel.ItisderivedfromPressurizerLevelcontrolsignalsLT1110X-2andLT1110Y-2whicharelinear.Thesetwosignalsareprocessedbyanaveragewithexpandedqualityalgorithm.Thisfunctionobtainstheaverageofallvalueswithagoodstatus.Italsosetsthequalityoftheresultbasedonthenumberofvalueswithgoodstatus,versusthetotalnumberofinputs.Thepossiblestatusvaluesare:~Greaterthan50%ofallinputshavegoodstatus,resultisgood.~Onlyonegoodvalueandthetotalinputsare3ormore,theresultispoor.~Whentherearenogooddatavalues,buttherearesomewithpoororsuspect,theresultIspoor.~TheresultIssuspectforallothercasesexceptallbad,inthiscasetheresultIsbad.ThetopoftheheatersIs73.98inchesabovethelowertopcenterline.ChargingFlowtoRegenHx(GPM)FT2212-1/2RCSCHG/MUN/AThisparameterisreactorcoolantsystemmakeupflow.ItIsconvertedtoengineeringunitsusingalinearequation.SubcoolingQA0005-1/2Margin(deg.F)SubmarginMinimalThisparameterIsderivedfromeightsubcooledvalues,TMARHEAD-A-1/2,TMARRCS-B-1/2,TMARUR-A-1/2,TMARHEAD-B-1/2,TMARCET-A-1/2,TMARUR-8-1/2,TMARRCS-A-1/2,andTMARCET-B-1/2,whichareprovidedbytheQualifiedSafetyParameterDisplaySystem(QSPDS).Theyareprocessedbyasignalauctioneeringminimumalgorithm.Thisfunctionfindsthehighestusabledatavalueinaspecifiedgroup.Eachdatavalueofthegroupanditsqualityisexaminedandthefollowingquantitiesareobtained:1.Lowestusabledatavalue.,2.Pointnumberofthelowestusabledatavalue,3.Numberofusabledatavalues,and4.Lowestqualityoftheusabledata.~Fortwoormoreusabledatavalues,theresultisthehighestusablevalueandthequalityisthelowestqualityoftheusabledata.~Foronlyoneusabledatavalue,theresultissettothatvalueandthequalityispoor.~Fornousabledata,thevalueoftheresultIssettothehighestofallthe(bad)dataandthequalityisbad.
REVISIONNo.:PROCEDURENO.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHE,EMERGENCYOPERATIONSFACILITYPAGE:54of117EPIP-06ST.LUCIEPLANTATTACHMENT7BERDADSDATAPOINTS(Page3of8)POINTDESCRIPTIONPTIDAvg.CoreExitQA0003-1/2Temperature(deg.F)ReactorVesselUnit1:Level(%)QA00041Unit2:RLEVH-2RLEVP-2POINTNAMETemp.CoreEx.TYPECALCULATIONAverageMinimumNOTESThisparameterIsderivedfrom45Unit1detectors,or56Unit2detectorslocatedjustabovetheupperfuelalignmentplate.TheQualifiedSafetyParameterDisplaySystem(QSPDS)providesthevalues.Theyareprocessedbyanaverageviithexpandedqualityalgorithm.Thisfunctionobtainstheaverageofallvalueswithagoodstatus.Italsosetsthequalityoftheresultbasedonthenumberofvalueswithgoodstatus,versusthetotalnumberofinputs.Thepossiblestatusvaluesare:~Greaterthan50%ofInputshavegoodstatus,resultisgood.~Onlyonegoodvalueandthetotalinputsare3ormore,theresultIspoor.~Whentherearenogooddatavalues,buttherearesomewithpoororsuspect,theresultispoor.~Theresultissuspectforallothercasesexceptallbad,inthiscasetheresultisbad.ThereactorvessellevelforUnit1QA0004-1isderivedfromthereactorvessellevelsRLEV-A-1andRLEV-B-1whichareprovidedbytheQualifiedSafetyParameterDisplaySystem.TheERDADSselectthelowestofthetwovalues.Foronlyonegooddatavalue,theresultissettothatvalueandthequalityispoor.ThereactorvessellevelforUnit2IsdisplayedasreactorplenumlevelRLEVPB-2andreactorheadlevelRLEVHB-2whichIsprovidedbythe'8'ideQualifiedSafetyParameterDisplaySystem(QSPDS).ThesetwoparametersaredisplayedwithnocalculationsbeingperformedbytheERDADScomputersystem.TheQSPDSobtainsthesevaluesfromtheheatedandunheatedjunctionthermocoupleslocatedinsidethereactor.Theyarepositionedbetweentheheadandupperfuelalignmentplateinthereactorinternals.
REVISIONNO.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT7BERDADSDATAPOINTS(Page4of8)PAGE:55of117POINTDESCRIPTIONReactorVesselLevel%(contintted)PTIDPOINTTYPENAMECALCULATIONUnit1LevelInformation:NOTESHeadandPlenumtogetherSensorNone123456781861/41443/8108715/8505/8295/8195/8105/8201918141075710080614329191270Location('n.tofuelLevelValueif~annmenttate~Sement%~Uncovered%Unit2LevelInformation:HeadseparatefromPlenumSensorNone123None456781701/21403/41111/8985/8745/8535/8325/8125/8522820182120192210048200100826141220Locationn.tofuelLevelValueif~alnmenttate~aement%~Uncovered%
1' REVISIONNO.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT7BERDADSDATAPOINTS(Page5of8)PAGE:56of117POINTDESCRIPTIONHPSITotalFlow(GPM)PTIDHSITTLF-1/2POINTNAMEHPSIFlowTYPECALCULATIONSumNOTESThisparametermeasurestotalHPSIflowandisderivedfromHPSIHeaderFlowsignalsFT3311-1/2,FT3321-1/2,F73331-1/2andFT3341-1/2whicharesquareroots.Thesignalsareprocessedwithasumofinputsalgorithm.Thisfunctionobtainsthealgebraicsumofvalueswithagoodstatus.LPSITotalFlow(GPM)QA0908-1/2LPSIFlowSumThisparametermeasurestotalLPSIflowandisderivedfromLPSIHeaderFlowsignalsF73312-1/2,FT3322-1/2,FT3332-1/2andFT3342-1/2whicharesquareroots.ThesesignalsareprocessedbyanalgorithmwhichprovidesasumoftheInputs.Thisfunctionobtainsthealgebraicsumofvalueswithagoodstatus.ContainmentTemp.TE07-3B-1/2(deg.F)ContainmentQA0507-1/2PressureWR(psig)CntmntTefllpCtmntPressAverageThisparameterIsacontainmenttemperatureinstrument.Itisconvertedtoengineeringunitsusingalinearequation.Thisparametermeasurescontainmentpressureandisawiderangeindicator.ItisderivedfromWideRangeContainmentPressuresignalsPT07<A1-1/2andPT07<B1-1/2whicharelinear.Theyareprocessedbyanaveragewithexpandedqualityalgorithm.Thisfunctionobtainstheaverageofallvalueswithagoodstatus.Italsosetsthequalityoftheresultbasedonthenumberofvalueswithgoodstatus,versusthetotalnumberofInputs.Thepossiblestatusvaluesare:~Greaterthan50%ofallinputshavegoodstatus,resultisgood.~Onlyonegoodvalueandthetotalinputsare3ormore,theresultispoor.~Whentherearenogooddatavalues,buttherearesomewithpoororsuspect,theresultispoor.~TheresultIssuspectforallothercasesexceptallbad,inthiscasetheresultisbad.
REVISIONNO.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT7BERDADSDATAPOINTS(Page6of8)PAGE:57of117POINTDESCRIPTIONPTIDContainmentSumpQA0008-1/2LevelWR(Ft.)POINTNAMECntmntSmpWRTYPECALCULATIONMaximumNOTESThisparameterisacontainmentsumpwiderangeinstrument.ItisderivedfromContainmentSumpLevelsignalsLT07-13A-1/2andLT07-138-1/2whicharelinear.Theyareprocessedbyasignalauctioneeringmaximumalgorithm.Thisfunctionfindsthehighestusabledatavalueinthespecifiedgroup.EachdatavalueofthegroupanditsqualityIsexaminedandthefollowingrulesareused.~Fortwoormoreusabledatavalues,theresultisthehighestusabledatavalueandthequalityisthelowestqualityoftheusabledata.~Foronlyoneusabledatavalue,theresultissettothatvalueandthequalityIspoor.ContainmentHydrogen(%)CH2-1/2H2Conc.Average~Fornousabledata,thevalueoftheresultissettothehighestofallthe(bad)dataandthequalityIsbad.Thisparameterisacontainmenthydrogenaverageconcentrationmeasurement.ItisderivedfromHydrogenConcentrationsignalsA-HYDROGEN-1/2and8-HYDROGEN-1/2whicharelinear.Thesesignalsareprocessedbyanaveragewithexpandedqualityalgorithm.Thisfunctionobtainstheaverageofallvalueswithagoodstatus.Italsosetsthequalityoftheresultbasedonthenumberofvalueswithgoodstatus,versusthetotalnumberofinputs.Thepossiblestatusvaluesare:~Greaterthan50%ofallinputshavegoodstatus,resultisgood.SGLevelAWR(%)SGLevel8WR(%)LT9012-1/2LT9022-1/2SGLevelASGLevel8N/A~Onlyonegoodvalueandthetotalinputsare3ormore,theresultispoor.ThisparameterIstheAsteamgeneratorwiderangelevelinstrument.ItIsconvertedtoengineeringunitsusingalinearequation.LTCL=LowerTapCenterLine.Thelowertapis21InchesabovethebottomoftheUtubes.Thisparameterthe'8'teamgeneratorwiderangelevelInstrument.Itisconvertedtoengineeringunitsusingalinearequation.LTCL=LowerTapCenterUne.ThelowertapIs21inchesabovethebottomoftheUtubes.
REVISIONNO.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT7BERDADSDATAPOINTS(Page7of8)PAGE:58of117POINTDESCRIPTIONPTIDPOINTNAMETYPECALCULATIONNOTESSGPressureAQA0021-1/2(psig)SGPresJARedundantSensorAlgorithmThisparameteristheA'teamgeneratorpressure.ItisderivedfromthreeSteamGeneratorPressureSignals,PT8013A-1/2,PT8013B-1/2,andPT8013C-1/2,whicharelinear.Thesesignalsareprocessedbyaredundantsensoralgorithm.ThisfunctionobtainstheaverageofthecurrentvaluesthathaveagoodstatusandaredosetothestatisticalmaJority.SGPressureB(psig)QA0022-1/2SGPresJBRedundantSensorAlgorthimThisparameteristhe'Bsteamgeneratorpressure.ItIsderivedfromthreeSteamGeneratorPressureSignals,PT8023A-1/2,PT8023B-1/2,andPT8023D-1/2,whicharelinear.Thesesignalsareprocessedbyaredundantsensoralgorithm.Thisfunctionobtainstheaverageofthecurrentvaluesthathaveagoodstatusandareclosetothestatisticalmajority.RefuelingWaterRWTAL-1/2TankAvg.Level(Ft)BWSTLevelAverageThisparametermeasuresrefuelingwatertanklevel.Itisderivedfromthreeinputs.TheyareLT07-2A-1/2,LT07-2B-1/2,andLT07-2C-1/2.Thesepointsareprocessedbyanaveragewithexpandedqualityalgorithm.Thisfunctionobtainstheaverageofallvalueswithagoodstatus.Italsosetsthequalityoftheresultbasedonthenumberofvalueswithgoodstatus,versusthetotalnumberofinputs.Thepossiblestatusvaluesare:~Greaterthan50%ofinputshavegoodstatus,resultisgood.~Onlyonegoodvalueandthetotalinputsare3ormore,theresultispoor.~Whentherearenogooddatavalues,buttherearesomewithpoororsuspect,theresultispoof.~Theresultissuspectforallothercasesexceptallbad,inthiscasetheresultisbad.Tankbottomreferstozerogallons.
REVISIONNO.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT7BERDADSDATAPOINTS(Page8of8)PAGE:59of117POINTDESCRIPTIONPTIDPOINTNAMETYPECALCULATIONNOTESCHRRM.Channel(R/HR)Unit1:Cntmnt.RadRE26-58-1(AChannel)RD26-59-1(BChannel)Unit2:RIM2640-2(AChannel)RIM2641-2(BChannel)MaximumThehighcontainmentradiationinstrumentsforUnit1aretheAsidemonitorRE26-58-1andthe'B'idemonitorRE26-59-1.Thesemonitorsareonlyrangecheckedandflaggedbadifoutofrange.Bothdetectorsarelocatedatthe90footcontainmentelevationandarepositionedat0and180degrees.ThehighcontainmentradiationinstrumentsforUnit2arethe"A'idemonitorRIM26-40-2andthe'B'idemonitorRIM2641-2.Thesemonitorsareonlyrangecheckedandareflaggedbadifoutofrange.Bothdetectorsarelocatedatthe90footcontainmentelevationandarepositionedat0and180degrees.
REVISIONNo.:PROCEDURENo.EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT8EOFSTATUSBOARDKEEPERCHECKLIST(Page1of2)PAGE:60of117NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.IdentifyavailabilitytoEOFProjectEngineer.B.FACILITYOPERATION1.Stepstooccurcontinuallywhilethefacilityisinoperation:a.ObtainthefollowingERDADSdatasheets(printouts)fromtheEOFAdministrativeStaff:1.St.LucieEOFDataSheet(EF1/2).2.RadioactiveGaseousSourceTerms(RG1/2).~b.UpdatestatusboardswithnewERDADSdata.c.Verifythatalldatahasbeenaccuratelytransferredtothestatusboards.d.Updatethesequenceofeventsboardfollowingeachfacilitybriefingandasneeded.Providerelevantinformationconcerningitemssuchas:1.Changeinclassification.2.Significantchangeinplantcondition.3.Statusofplantsystem(s)ofconcern.
REVISIONNo.:PROCEDURENo.EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT8EOFSTATUSBOARDKEEPERCHECKLIST(Page2of2)PAGE:61of117B.FACILITYOPERATION(continued)1.(continued)d.(continued)4.Injuredpersonnelstatus.5.Otheritemsofrelevantinterest.e.Makecorrections,whenidentified,bycirclingthecorrecteddata.f.Whenallstatusboardcolumns/blanksarefilled,erasethefirsttwocolumns/blanks,enternewdata,withadifferentcoloredmarker,leavingaspacebetweenthenewandtheolddata.C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.Statusboardshavebeenclearedandreturnedtopre-activationcondition.2.ReturnedpositionnotebooktotheRMoffice.3.ProvidedallcompletedpaperworktotheEOFProjectEngineer.
REVISIONNo.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT9EOFNUCLEARLICENSINGMANAGERCHECKLIST(Page1of3)PAGE:62of117NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.Verifythatthefollowingpositionsarefilled:a.EOFCommunicator(4)NOTEPositionsshouldbefilledinthisorder.1.HotRingDown(HRD)Phone2.EmergencyNotificationSystem(ENS)3.TSC(directline)4.HealthPhysicsNetwork(HPN)B.FACILITYOPERATION1.InitiatetheLicensingLogbook(useAttachment9A,TypicalInformationtobeincludedintheLogbook)~$32.VerifyINPOwasnotified.3.Ensurebackupcommunicationsdevicesareavailableand'perable(workwiththeEOFAdministrativeSupervisor).
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT9EOFNUCLEARLICENSINGMANAGERCHECKLIST(Page2of3)PAGE:63of117B.FACILITYOPERATION(continued)4.Stepstooccurcontinuallywhilethefacilityisinoperation:a.Manage/superviseactivitiesofEOFcommunicators(HRD,ENS,TSC,HPN).b.EnsurecommunicationswiththeNRC(ENS,HPN)areloggedbythecommunicators.c.EnsurecoordinationwithINPOismaintainedconcerningindustryassistancerequests(ifnotbeinghandledbytheNDDO).e.ServeasprimaryliaisonwiththeNRConcetheSiteTeamarrivesattheEOF,interfacingwiththeEmergencyResponseCoordinator.1.ErisureNRCworklocationsarefunctional.INITIAL2.CoordinatetheNRCinterfacewiththeFPLERO,andStateandCountyrepresentativesintheEOF.3.Provideaccesstonotificationforms,pressreleases,andotherinformation,asrequested.C.FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.Allcommunicationslinksterminated.2.Allcommunicationspaperworkcollected.
REVISIONNo.:3PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT9EOFNUCLEARLICENSINGMANAGERCHECKLIST(Page3of3)PAGE:64of117C.FACILITYCLOSEOUTANDRESTORATION(continued)3.Alldocuments,equipment,andsuppliesreturnedtopre-activationconditionand/orlocation.4.ClosedouttheLicensingLogbook.5.PreparedIncidentReport(formatavailableinFloridaPower&LightNuclearPlantRecoveryPlant)forreviewandapprovalbyRM.6.ReturnedpositionnotebooktotheRMoffice.7.ProvidedallcompletedpaperworktotheRM,INITIAL REVISIONNO.:3PROCEDURENO.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:65of117EPIP-06ST.LUCIEPLANTATTACHMENT9ATYPICALINFORMATIONTOBEINCLUDEDINTHELOGBOOK(Page1of1)Maintainingconcise,detailedlogsduringanemergencyeventisimportant.Followingtheevent,allinformationrecordedwillbeneededtoprovideaclearpictureofactionstaken.A.ThefollowinginformationshouldbeincludedintheLogbook:1.Keyevents(e.g.,classificationchanges,injuries,etc.).2.Statuschangesinequipment,radiologicalconditions,personnel,etc.3.Decisionsmadeoractionstaken.4.Otheritemsofsignificance.B.Logentryrequirements:Timeofentry.2.Useink.3.Write/printlegibly.4.Useconciseandaccuratewording.5.Strikethroughandinitialchanges.6.DonotremovepagesfromLogbook.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT10EOFCOMMUNICATORCHECKLIST(Page1of4)PAGE:66of117NOTE1.ThischecklistappliestoallEOFCommunicatorpositionsasfollows:HRDCommunicatorTSCCommunicatorENSCommunicatorHPNCommunicator2.Whennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.NOTEThefirstEOFCommunicatortoarriveattheEOFshouldidentifyhimself/herselftotheRM.2.IdentifyavailabilitytotheEOFLicensingManager.3.ReviewAttachment10A,CommunicationsGuidelines.4.(TSC)RequestcopyoftheECLog,completednotificationformsandchecklists,andotherpertinentinformationbetransmittedtotheEOF.
REVISIONNO.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT10EOFCOMMUNICATORCHECKLIST(Page2of4)PAGE:67of117B.FACILITYOPERATIONINITIAL1.(HRD)CompleteturnoverwithTSCHRDCommunicator,assumeresponsibilityforState/Countynotifications.2.(ENS)CompleteturnoverwithTSCENSCommunicator,assumeleadresponsibilityforNRCnotifications.3.(TSC)EstablishdirectlinelinkwithTSC.4.(HPN)EstablishconnectiononNRCHPconferencebridge.5.Stepstooccurcontinuallywhilethefacilityisinoperation:HRDCommunicationsa.AssisttheRMwithStateandCountynotificationsby:1.ReviewingtheStateNotificationFormforcompleteness.2.Asnecessary,ensuringProtectiveActionRecommendations(PARs)matchthePARsWorksheet(seeNotificationfromtheEmergencyOperationsFacilityinEPIP-08,Off-siteNotificationsandProtectiveActionRecommendations).3.EnsuringtheRMhasapprovedtheform.b.TransmitthenotificationfrominaccordancewithEPIP-08.c.RequesttheEOFRMOPSAdvisor/Logkeeperlognotificationtimes.
REVISIONNo.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT10EOFCOMMUNICATORCHECKLIST(Page3of4)PAGE:68of117B.FACILITYOPERATION(continued)5.(continued)ENS/HPNCommunicationsa.Maintainanopenlineofcommunicationandatransmissionlog.b.(ENS)Ensurenotificationsareinitiatedwithin1hour(immediatelyfollowingStateandCountynotification)ofaclassification/PARchangeorothersignificantevent.RefertoEPIP-08ifadditionalinformationisneeded.c.RequesttheEOFRMOPSAdvisor/Logkeeperlognotificationtimes.d.LogallquestionsaskedbyNRC.e.ObtainanswerstoquestionsfromappropriateEOFManager.f.ObtainRMapprovalpriortoprovidingadditionalinformationtotheNRC.TSCCommunicationsa.MaintainanopenlineofcommunicationwiththeTSC.b.IfERDADSisoutofservice,obtainplantparameterandradiologicaldata(useAttachment10B,PlantDataSheetandRadioactiveGaseousSourceTerms)throughphoneconversationwiththeTSC(EOFCommunicator)~c.ClarifyanydiscrepantinformationwiththeTSC(EOFCommunicator),asrequested.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT10EOFCOMMUNICATORCHECKLISTPAGE:69of117(Page4of4)C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1~Allcommunicationlinks(HRD,ENS,HPN,TSC)terminated.2.Allcommunicationspaperworkcollected.3.Allphoneequipmentreturnedtopre-activationcondition.4.ReturnedpositionnotebooktotheRMoffice.5.ProvidedallcompletedpaperworktotheEOFNuclearLicensingManager.
REVISIONNO.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT'IOACOMMUNICATIONSGUIDELINES(Page1of8)PAGE:70of117I.GeneralGuidelinesAlwaysspeakclearly,firmly,andwithnormaltonewhenusinganycommunicationssystem.2.Thesenderandreceivershallbeclearlyidentified.3.Messagetext:a.Communicationmustbefreeofambiguity.Slangtermsshallnotbeused.Avoidtheuseofwordsthatsoundalike;forexample,avoidincreaseanddecrease,useraiseandlowerinstead.b.Communicationsmustbespecific.Usenounnamesforplantequipment,notacronyms;forexampleuselowpressuresafetyinjectionpumpinsteadofLPSI.c.Thephoneticalphabetwillbeusedtoidentifyspecifictrain,bus,channel,orequipmentdesignations,notjustletteridentifier;forexample,refertothe1Alphaheaterdrainpump,notthe1Aheaterdrainpump.Thefollowingisthephoneticalphabettobeused:AAlphaBBravo-CCharlieDDeltaEEpsilonFFoxtrotGGolfHHotelIIndiaJJulietKKiloLLimaMMikeNNovember0OscarPPapaQQuebecRRomeoSSierraTTangoUUniformVVictorWWhiskeyXX-rayYYankeeZZulud.Thephoneticalphabetshouldnotbeusedforstringedletterreferences,acceptableacronyms,orlocationsymbols;forexample,ABbus,ACorDC,TSC,respectively.
REVISIONNo.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT10ACOMMUNICATIONSGUIDELINES(Page2of8)PAGE:71of117I~GeneralGuidelines(continued)4.Acknowledgementandconfirmation(3-waycommunication)-messagesshallbecomprisedofpropertransmission,acknowledgement,andconfirmation.a.Themessageisproperlytransmittedfromtheoriginatortothereceiver.b.Themessagereceivershallacknowledgethecommunicationbygivingafunctionalrepeat-backtothemessageoriginator.Therepeat-backcanbeprovidedbyeitherparaphrasingorexplainingthemessageinone'sownwords,orbyverbatimrepeat-back.Inallcases,verbatimrepeat-backshallbeusedforequipmentidentifiers.c.Ifthemessagereceiverdoesnotunderstandthemessagehe/sheshallaskforthemessagetoberepeated.d.Ifanincorrectrepeat-backisgiven,themessageoriginatorshallimmediatelycorrectthemiscommunicationwithastatementsuchas,"WRONG",followedbyrestatingthecorrectmessage.e.Themessageoriginatorshallconfirmtheacknowledgement(repeat-back)withastatementsuchas,"Thatiscorrect".5.UseofaCallSignisnotnecessarywhencommunicatingwiththeHPOff-siteChannelradio(stationIDoccursevery30minutesautomatically).6.TheCallSignshouldbecommunicatedperiodicallywhenusingtheLGR.
REVISIONNO.:PROCEDURENO.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:72of117EPIP-06ST.LUCIEPLANTATTACHMENT10ACOMMUNICATIONSGUIDELINES(Page3of8)I.GeneralGuidelines(continued)7.Priortotransmission,ensurethatinformationhasbeenverifiedandapprovedbytheappropriateauthority,asnecessary.8.EnsurethatanyincomingpertinentinformationisprovidedtotheRecoveryManageroranRMOPSAdvisor/Logkeeper.9.Maintaindocumentationofanysignificantinformationprovidedorreceived.II.CommunicationsSstems1.HRDCommunicatorA.StateWarningPoint(SWP)HotRingDownPhone(HRD)1.ThisistheprimarycommunicationspathwaytotheStateWarningPointandSt.LucieandMartinCounties.2.Aself-verifyingphonesystemwhichisinitiatedbyenteringthe3digitcodecorrespondingtothedesiredlocationofcontact.ThephonedialinglocationcodesareavailableintheSt.LuciePlantEmergencyResponseDirectory(ERD).Aconfirmationring-back(doubletone)willbeheardifthedialedterminalissuccessfullycontacted.Whenthepartyanswers,begintransmissionbydepressingthe"push-to-talk"barinthehandset.Releasethe"push-to-talk"bartoreceiveresponse.
REVISIONNO.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT10ACOMMUNICATIONSGUIDELINES(Page4of8)PAGE:73of117II.CommunicationsSstems(continued)h1.(continued)B.CommeicialTelephone1.ThisisthefirstalternatecommunicationspathwaytotheStateWarningPointandSt.LucieandMartinCounties.2.EOFTelephoneSystema.LongDistanceCalls(off-network):8+1+areacode+sevendigitnumber+authorizationcode(ifprompted)C.EmergencySatelliteCommunicationsSystem(ESATCOM)1.ThisisthesecondalternatecommunicationspathwaytotheStateWarningPointandSt.LucieandMartinCounties.2.AbackupcommunicationssystemtotheStateandCounties.Toinitiatetransmission,liftthehandsetanddepressthe"push-to-talk"barinthehandset.Wait3-5secondstohearabeepbeforestartingtotalk.Theredlightonthephoneisapowerindicator,whenlit,powerisavailable.
REVISIONNO.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:74of117ATTACHMENT10ACOMMUNICATIONSGUIDELINES(Page5of8)II.CommunicationsSstems(continued)1.(continued)D.LocalGovernmentRadio(LGR)-CALLSIGN:KILONOVEMBERGOLFROMEO8-7-4(KNGR874)1.ThisisthethirdalternatecommunicationspathwaytotheStateWarningPointandSt.LucieandMartinCounties.2.AbackupcommunicationssystemtotheCountiesandindirectlytotheState.Thesystemhastwolowbandradiofrequencies.ThereareseparateMotorolaCommandSeriestableradios,onesettotheprimarychannel,F2(39.180Mhz,Statechannel1)andtheothersettothesecondarychannel,F1(39.100Mhz,Statechannel2).Theradioscanbeoperatedeitherbydepressingthe"transmit"buttonontheconsoleorbyremovingthehandsetanddepressingthe"push-to-talk"barinthehandset.The"xmit"lightislitduringtransmission.(Preferenceshouldbegiventousingthehandset)~2.ENSCommunicatorA.EmergencyNotificationSystem(ENS)1.ThisistheprimarycommunicationspathwaytotheNRC.2.TheENSispartoftheNRCFTS2000phonesystem.InitiatecontactbydialingoneofthephonenumbersprovidedonthephoneofintheSt.LuciePlantEmergencyResponseDirectory(ERD).TheENSwillbecomeanopenlineofcommunicationatanALERTorhigheremergencyclass.TheTSCshouldmaintainthatopenlineuntiltheEOFisadequatelystaffed,thenboththeTSCandEOFshouldstayontheline.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT10ACOMMUNICATIONSGUIDELINES(Page6of8)PAGE:75of117II~CommunicationsSstems(continued)2.(continued)B.CommercialTelephone1.ThisisthebackupcommunicationspathwaytotheNRC.2.EOFTelephoneSystema.LongDistanceCalls(off-network):8+1+areacode+sevendigitnumber+authorizationcode(ifprompted)3.TSCCommunicatorA.TSCDirect-lineTelephone1~ThisisadirectlinetotheTechnicalSupportCenter(TSC).InitiatecontactbyremovingthehandsetfromthecradlewhichwillcausethephoneintheTSCtoring.Whenthephoneisanswered,begintransmission.ThislinkcanalsobeinitiatedfromtheTSC.4.HPNCommunicatorA.HealthPhysicsNetwork(HPN)1.TheHPNispartoftheNRCFTS2000phonesystem.TheHPNwillbecomeopenlineofcommunicationatanALERTorhigheremergencyclass.InitiatecontactbydialingoneofthephonenumbersprovidedintheSt.LuciePlantEmergencyResponseDirectory(ERD).RequestthattheNRCOperationsCenter(NRCOC)dutyofficerestablishtheHPNBridgeforSt.LuciePlant.IftheTSChasalreadyestablishedthebridge(withtheNRCOC),requesttobeaddedon.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT10ACOMMUNICATIONSGUIDELINES(Page7of8)PAGE:76of117III.OtherCommunicationsSstemsEOFTelephoneSystemA.St.LuciePlant:For4000and7000numbers;Dialthe4digitextensionFor3000numbers;Dial9+465-3550+the4digitextensionB.NetworkofInteroffice:8+FPLnetworknumber(example-totheGO8+552-XXXX)C.Intrafacility:Dialthe4digitextensionD.LocalCalls(off-network):9+outside7digitnumberE.LongDistanceCalls(off-network):8+1+areacode+7digitnumber+authorizationcode(onthephone)F.LocalDirectoryAssistance9+411 REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT10ACOMMUNICATIONSGUIDELINES(Page8of8)PAGE:77of117III~OtherCommunicationsSstems(continued)2.HPOff-siteRadioChannelA.Aunique900Mhzchannelforcommunicationswiththeoff-sitefieldmonitoringteams.TheTSChastheprimaryresponsibilityforcommunicatingwiththefieldteamsanduseofthisradiointheEOFisonlyasabackuptotheTSC.TheradioisaMotorolaSpectrawhichhasbeensetupsothattheHPOff-siteChannelisthe"home"channel.1.Topower-uptheradio:a.Plugthepowercordintothewalloutletbehindthetable.b.Presstheredbuttononthespeakerbox(AstronRS-12S)totheupposition,buttonwillilluminate.c.Depressthe"pwr"buttonontheSpectraradio.2.Tooperatetheradio:a.Depressthetransmitside(withthelightning,bolt)ofthemicrophonebaseandbegintransmission.
REVISIONNO.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT10BPLANTDATASHEET(Page1of3)PAGE:78of117ERDADSEF1/2ScreenMimicAvgRCSTholRCSPrzPresRCSPrzLvlChargingRowUmitlngSubooolingMrgnAverageCETRxVesselLvlHPSIRowLPSIFlowCTMTTempCTMTPres(WR)CTMTSumpLvl(NR)CTMTH2S/GLevel(WR)AS/GLevel(WR)8S/GPressureAS/GPressure8RWTLevelCHRRMCh.ACHRRMCh.8SAFEGUAADSHPSIAHPSI8LPSIALPSI8CHGPUMPACHGPUMP8CHGPUMPCCTMTCOOLERACTMTCOOLER8CTMTCOOLERCCTMTCOOLERDCCWACCW8CCWCCIRCULATIONRCPA1RCPA2RCP81RCP82LPSIALPSIBLPSIA1FLOWLPSIA2FLOWLPSI81FLOWLPSI82FLOWEMERGENCYDIESELGENERATORSAVOLTSVOLTSAMPSFEEDWATERSOURCEMAINFWPAMAINFWP8AFWAAFW8AFWCAMPSAMAINFEEDFLOW8MAINFEEDFLOWAAUXFEEDFLOW(GPM)8AUXFEEDFLOW(GPM)CAUXFEEDFLOW(GPM)ELECTRICALSYSTEMS4160A3(VOLTS)416083(VOLTS)6900A1(VOLTS)690081(VOLTS)(EPIP06B.WPG)
REVISIONNO.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT10BPLANTDATASHEET(Page2of3)ERDADSRG1ScreenMimicPAGE:79of117WINDSPEEDWINDDIRECTIONAIRTEMPDIFFTEMP10METER57.9METERMPHMPHDEGDEGDEGFDEGFDEGF/50METERCHANNELMAINSTEAMVALUEUNITSCHANNELCONTAINMENTVALUEUNITS05-01AMAINSTMMR/HR58'HlRANGER/HR05-02BMAINSTMMR/HR59BHlRANGER/HRPRESSUREPSIGCHANNELECCS1AVALUE02-05LOWRANGE02-07MIDRANGE02-09HlRANGE02-10FLOWUNITSCHANNELPLANTVENTVALUEUNITSuC/cc01-05LOWRANGEuC/ccuC/cc01-07MIDRANGEuC/ccuC/cc01-09HlRANGEuC/ccSCFM01-10FLOWSCFMCHANNELECCS1BVALUEUNITSCHANNEL03-05LOWRANGEuC/cc04-0503-07MIDRANGEuC/cc04-0703-09HIRANGEuC/cc04-0903-10FLOWSCFM04-10FUELBLDGVALUEUNITSLOWRANGEuC/ccMIDRANGEuC/ccHlRANGEuC/ccFLOWSCFM REVISIONNO.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT't08PLANTDATASHEET(Page3of3)ERDADSRG2ScreenMimicPAGE:80of117WINDSPEEDWINDDIRECTIONCURRENTTEMPDIFFTEMP10METER57.9METERMPHMPHDEGDEGDEGFDEGFDEGFCHANNELMAINSTEAMVALUEUNITSCHANNELCONTAINMENTVALUEUNITS631AMAINSTMMR/HR40AHlRANGER/HR632BMAINSTMMR/HR41BHlRANGER/HR633BACKGROUNDMR/HRPRESSUREPSIGCHANNELECCS2AVALUEUNITSCHANNELPLANTVENTVALUEUNITS601LOWRANGEUC/cc621LOWRANGEuC/cc602MIDRANGEUC/cc622MIDRANGEuC/cc603HlRANGEuC/cc623HlRANGEuC/cc604EFFLUENTuC/SEC524EFFLUENTuC/SECCHANNELECCS2BVALUEUNITS611LOWRANGEUC/cc612MIDRANGEuC/cc613HIRANGEuC/cc614EFFLUENTUC/SEC REVISIONNO.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT11COUNTYTECHNICALADVISORCHECKLIST(Page1of2)PAGE:81of117NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.IfarrivingatEOF:a.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.b.IdentifyavailabilitytotheEIM.c.TakeacopyofyourchecklistwhendispatchedtotheCounty.ORIfarrivingattheEmergencyOperation'sCenterorhavingbeendispatchedfromtheEOF:a.IntroduceyourselftotheEOCstaff.b.ContacttheEOFandnotifyTheEIMoranEIM/ENCTechnicalAdvisorofyourcontactphonenumber.c.Requestacopyofyourchecklistbetelecopiedtoyou.
REVISIONNo.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT11COUNTYTECHNICALADVISORCHECKLIST(Page2of2)PAGE:82of117B.FACILITYOPERATIONINITIAL1.Stepstooccurcontinuallywhilethefacility(EOC)isinoperation:a.Provideoverviewofaccidentconditionsandplantstatus.b.AnswertechnicalquestionsandaddclarificationofissuesnotunderstoodintheEOC.c.ContactpersonnelintheEOFforassistanceinobtaininginformation(usetheERD).d.Participateinfacility(EOC)briefings,asrequested.C.FACILITYCLOSEOUTANDRESTORATION1.DebriefedwithEOCManager.2.Collectedallgeneratedpaperwork.3.ClosedoutwiththeEIMorEIM/ENCTechnicalAdvisor.4.ReturnpositionnotebookandcompletedpaperworktoEmergencyPlanningassoonaspossible.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCY'OPERATIONSFACILITYST.LUCIEPLANTATTACHMENT12EOFHEALTHPHYSICSMANAGERCHECKLIST,(Page1of3)PAGE:83of117NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1~Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.Verifythatthefollowingpositionsarefilled:a.EOFDoseAssessor/FMTCoord(3)b.EOFHPTechSupportc.EOFRadStatusBoardsKeeperB.FACILITYOPERATION1.InitiatetheHPLogbook.2.ConductaturnoverwiththeTSCChemistrySupervisorpriortocommencingdoseassessment.3.ConductaturnoverwiththeTSCHPSupervisorpriortotakingovertheFieldMonitoring,Teams.4.RequestthatclocksintheDoseAssessmentareabesynchronizedwithERDADS.IncaseofERDADSfailure,synchronizewiththeaffectedControlRoom.5.Stepstooccurcontinuallywhilethefacilityisinoperation:a.Monitorradiologicalconditionsassociatedwiththeemergency.b.ManagethedoseassessmentandfieldmonitoringactivitiesintheEOF.
REVISIONNo.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITY'T.LUCIEPLANTATTACHMENT12EOFHEALTHPHYSICSMANAGERCHECKLIST(Page2of3)PAGE:84of117B.FACILITYOPERATION(continued)5.(continued)c.RoutinelyupdatetheRMonradiological/meteorologicalconditionsandpotentialimpacttotheevent.d.AssisttheRMindeterminingPARsbaseonradiologicalconditions(useEPIP-08,Off-siteNotificationsandProtectiveActionRecommendations).e.ReviewemergencydoseextensionswiththeRMandtheEC(useAttachment12A,BasisforExposureLimitsforEmergencyResponsePersonnel).f.ProvidetechnicalsupporttoEOFCommunicators.g.InterfacewiththeEOFETMtoresolveissuesinvolvingplantcomponentsaffectingplantreleases.h.ProvideradiologicalinformationtosupporttheEOFEIMandtheEmergencyNewsCenter(ENC).i.InterfacewiththeStateBureauofRadiationControl~j.KeeptheRMabreastofthestatusofBureauofRadiationControlactivities.k.InterfacewiththeNRCProtectiveMeasuresCoordinatorwhentheNRCSiteTeamarrivesonsite.I.SupportrecoveryplanningasrequestedbytheRM.
REVISIONNo.:3PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHE.EMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT12EOFHEALTHPHYSICSMANAGERCHECKLIST(Page3of3)PAGE:85of117C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1~AllradiologicalassessmentactivitiesintheEOFhavebeenterminated.2.AllHPpaperworkiscollected.3.Alldocuments,equipment,andsuppliesreturnedtopre-activationconditionand/orlocation.4.ClosedouttheHPLogbook.5.ReturnedpositionnotebooktotheRMoffice.6.ProvidedallcompletedpaperworktotheRM.
REVISIONNO.:3PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT12Ag~,QBASISFOREXPOSURELIMITSFOREMERGENCYRESPONSEPERSONNEL(Page1of3)PAGE:86of117ExposuretoemergencyresponsepersonnelshouldbemaintainedAsLowAsReasonablyAchievable(ALARA).Actionstakenduringanemergencyshouldtakeintoconsiderationtheamountofexposurerequiredtoaccomplishthetaskversusthepotentialbenefittothepublichealthandsafety.Conditionsmaywarrantre-entryintohighradiationareasleadingtoexposureinexcessoftheregulatorylimit.Exceptforrescueofpersonnel(life-savingonly),authorizationmustbegiveninadvancebytheEmergencyCoordinator(EC)inconsultationwiththeTSCHealthPhysicsSupervisor(oralternate)~Iftimepermits,theECshouldobtainconcurrencefromtheRecoveryManageriftheEOFisoperational~Inanycase,whereregulatorylimitshavebeenexceededtheECshallnotifytheRMoftheevent.ForthoseremotecircumstancesinvolvinganeventinprogressandobtainingECapprovalwillresultinleavingtheaccidentsceneordecreasethevictim(s)chanceofsurvival,lifesavingactionsmaybeperformedwithoutobtainingECapproval.TheECshallbenotifiedimmediatelyfollowingtherescueoperation.Re-entrypersonnelthathavebeenselected/chosentoexceedregulatoryexposurelimitsshouldbevolunteers'"',broadlyfamiliarwiththerisksinvolved(radiosensitivityoffetuses,effectsofacuteexposures,etc.),whosenormaldutieshavetrainedthemforsuchmissions.EPA400ManualofProtectiveActionGuidesandProtectiveActionsforNuclearIncidents,EPA400-R-92-001statesthat"Toassureadequateprotectionofminorsandtheunbornduringemergencies,theperformanceofemergencyservicesshouldbelimitedtonon-pregnantadults"~FPLendorsesthisguidance;however,FPLrecognizesthatitistherightoftheworkertomakethedecisiontoperformasanon-siteemergencyworker,understandingthepotentialrisksinvolved.Since,bytheirverynature,emergencyexposuresrequiringimmediateactionarenotplanned,theyarenotcontrolledasaPlannedSpecialExposure.Dosereceivedfromexposureunderemergencyconditionswillbeaddedtothedosereceivedduringthecurrentyear,priortotheemergency,todeterminecompliancewiththeoccupationaldoselimitsin10CFR20.
REVISIONNo.:3PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT12ABASISFOREXPOSURELIMITSFOREMERGENCYRESPONSEPERSONNEL(Page2of3)PAGE:87of117Dosesaboveregulatorylimitswillrequirereportingpursuantto10CFR20.2202and20.2203.AnydoseinexcessoftheannuallimitsspecifiedinSection20.1201(a)willbeaccountedforinaccordancewith10CFR20.1206(e).Ifanindividualexceedsanyoftheselimits,thentheindividualwillnotbeavailableforadditionaldoseunder20.1201(a).NOTE1~BothTotalDose(TEDE)andThyroidDose(CDE)shouldbeusedforpurposesofcontrollingexposure.2.Protectiveclothing,includingrespirators,shouldbeusedwhereappropriate.Forthefollowingmissions,theexposurelimitis"':TotalDose"'HYROID"'TEDE)(CDE)Performanceofactionsthatwouldnotdirectlymitigatetheevent,minimizeescalation,orminimizeeffluentreleases.5REM50REMPerformanceofactionsthatmitigatetheescalationtotheevent,rescuepersonsfromanon-lifethreateningsituation,minimizeexposuresorminimizeeffluentreleases.10REM100REMPerformanceofactionsthatdecreasetheseverityoftheeventorterminatetheprocessescausingtheeventinanattempttocontroleffluentreleasestoavoidextensiveexposureoflargepopulations.Af,fpf~fif-Asituation.25REM250REM~ff(Volunteers'"'houldbeabovetheageof45.)(5)(5)
REVISIONNO.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT12Ag$4BASISFOREXPOSURELIMITSFOREMERGENCYRESPONSEPERSONNEL(Page3of3)PAGE:88of117(1)Exposurelimitstothelensoftheeyeare3timestheTotalDose(TEDE)valueslisted.(2)TotalDose(TEDE)isthetotalwholebodyexposurefrombothexternalandinternal(weighted)sources-TotalEffectiveDoseEquivalent.(3)ThyroidDose(CDE)commitmentfrominternalsources-CommittedDoseEquivalent.Thesamedoselimitsalsoapplytootherorgans(CDE),skin(ShallowDoseEquivalent)andextremities(ExtremityDoseEquivalent).(4)Volunteerswithfullawarenessofrisksinvolvedincludingnumericallevelsofdoseatwhichacuteeffectsofradiationwillbeincurredandnumericalestimatesoftheriskofdelayedeffects.(5)NoupperlimitforTotalDose(TEDE)and/orThyroidDose(CDE)exposurehasbeenestablishedbecauseitisnotpossibletoprejudgetherisksthatonepersonshouldbeallowedtotaketosavethelifeofanother.Also,nospecificlimitisgivenforthyroidexposuresinceintheextremecase,completethyroidlossmightbeanacceptablesacrificeforalifesaved.Thisshouldnotbenecessaryifrespiratorsand/orthyroidprotectionforrescuepersonnelareavailableastheresultofadequateplanning.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT13EOFDOSEASSESSOR/FMTCOORDCHECKLIST(Page1of2)PAGE:89of117NOTE1.TheresponsibilitiesoftheFMTCoordinatorareprovidedinEPIP-10,Off-SiteRadiologicalMonitoring.2.Whennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.'.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.IdentifiedavailabilitytoRM(serveasinitialEOFHPManager)ORIdentifiedavailabilitytoEOFHPManager.B.FACILITYOPERATIONNOTE1.InitialoperatinginstructionsforuseoftheClassAModelareprovidedinEPIP-09,Off-SiteDoseCalculations.2.IfthecomputerizedClassAModelisnotavailable,doseassessmentshallbeconductedinaccordancewithEPIP-09.1.EstablishcommunicationlinkwiththeTSCDoseAssessor.2.RequestallpreviousdosecalculationpaperworkfromtheTSC.3.CompleteClassAModelQCcheck.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:90of117ATTACHMENT13EOFDOSEASSESSOR/FMTCOORDCHECKLIST(Page2of2)B.FACILITYOPERATION(continued)w4.Stepstooccurcontinuallywhilethefacilityisinoperation:a.ObtaininputdatafortheClassAModelfromtheEOFERDADSOperator(RG1/2Screen).b.CoordinatedoseassessmentwiththeTSC.INITIALc.ProvidestatusboardupdateinformationtotheEOFRadStatusBoardkeeper(usethe"StatusBoard"printoutfromtheClassAProgram.d.CoordinatedoseassessmentwiththeStateBureauofRadiationControl.e.Review/comparefieldmonitoringresultswithdosecalculations.f.ReportdoseassessmentresultstotheEOFHPManager.C.FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.Alldoseassessmentactivitiesterminated.2.TSCcommunicationslinkterminated.3.Alldocuments,equipment,andsuppliesreturnedtopre-activationconditionand/orlocation.4.Allpaperworkcollected.5.ReturnedpositionnotebooktotheRMoffice.6.ProvidedallcompletedpaperworktoEOFHPManager.
REVISIONNo.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT14EOFHPTECHSUPPORTCHECKLIST(Page1of2)PAGE:91of117NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIALRefertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.IdentifyavailabilitytoEOFHealthPhysicsManager.B.FACILITYOPERATION1.SynchronizeclocksintheHPareawithERDADS.IncaseofERDADSfailure,synchronizewiththeaffectedControlRoom.2.Stepstooccurcontinuallywhilethefacilityisinoperation:a.Assistindoseassessmentand/orfieldmonitoringactivities,asneeded.b.EnsureHPdatapostedonstatusboardsarecurrent.c.ProvidesupporttotheEOFHealthPhysicsManagerasrequested.d.SupporttheEOFHealthPhysicsManagerinestablishing24hourstaffing,reportstaffingtotheEOFAdministrativeSupervisor.e.ProvideHPtechnicalinformation/supporttotheEmergencyNewsCenter(ENC)andassistwithpressbriefings,asnecessary.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT14EOFHPTECHSUPPORTCHECKLIST(Page2of2)PAGE:92of117C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.AssistedwithterminationofallHPactivitiesintheEOF/ENC.2.Alldocuments,equipment,andsuppliesreturnedtopre-activationconditionand/orlocation.3.ReturnedpositionnotebooktotheRMoffice.4.ProvidedallcompletedpaperworktotheEOFHPManager.
REVISIONNo.:3PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT15EOFRADSTATUSBOARDKEEPERCHECKLIST(Page1of2)PAGE:93of117NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.IdentifyavailabilitytotheEOFHealthPhysicsManager.B.FACILITYOPERATION1.VerifyHPEmergencyKitinventory.2.Stepstooccurcontinuallywhilethefacilityisinoperation:a.ObtaindatafromtheEOFDoseAssessorandEOFFMTCoordinator.b.Updatestatusboardswithnewradiologicaldata.c.Verifythatalldatahasbeenaccuratelytransferredtothestatusboards.d.Makecorrections,whenidentified,bycirclingthecorrecteddata.e.Whenallstatusboardcolumns/blanksarefilled,erasethefirsttwocolumns/blanks,enternewdata,withadifferentcoloredmarker,leavingspacebetweenthenewandtheolddata.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT15EOFRADSTATUSBOARDKEEPERCHECKLIST(Page2of2)PAGE:94of117C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.Statusboardshavebeenclearedandreturnedtopre-activationcondition.2.EquipmentandsupplieshavebeenreturnedtotheHPEmergencyKit.3.ReturnedpositionnotebooktotheRMoffice.4.ProvidedallcompletedpaperworktotheEOFHPManager.
REVISIONNO.:PROCEDURENo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:95of117EPIP-06ST.LUCIEPLANTATTACHMENT16EOFADMINISTRATIVESUPERVISORCHECKLIST(Page1of3)NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.IdentifyavailabilitytotheRecoveryManager.3.DirectanEOFAdministrativestaffmembertopostallEPIPrevisionnumbersonthestatusboard.4.Ensurefacilitypublicaddresssystemisturnedon(amplifierinAdministrationarea,Room102)andconductatestpageusingtheRMmicrophone.a.CoverageincludestheBullpenandthesurroundingofficeareas.b.CoverageDOESNOTincludetheEmergencyNewsCenter(ENC).5.Ensurethe"Videolink"systemisturnedon.a.TurnonthemastervideoswitchlocatedintherackmountcabinetinRoom132(key¹14inkeybox).b.Inthe"Bullpen"turnonthetwotelevisionsetsusingtheremotecontrols(oneforeachtelevisionset)ontheRMtable.c.Setthechannelselectortochannel7andadjustvolume.
REVISIONNo.:3PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT16EOFADMINISTRATIVESUPERVISORCHECKLIST(Page2of3)PAGE:96of117B.FACILITYOPERATIONINITIAL1,Ensureprocedures,otherdocumentsanddrawingsareavailableandtherevisionnumbersverified.2.Stepstooccurcontinuallywhilethefacilityisinoperation:a.ManageEOFAdministrativeStaff.b.Ensurephotocopiers,telecopiers,computers,printers,andtelephonesaremaintainedoperable.c.Supervisedistributionofalldata,notificationforms,andotherinformation.d.FacilitatedistributionofclericalsuppliestoallgroupsintheEOF.e.Coordinatewithfacilitymanagersordesignee,toestablish24hourstaffingandcompletingAttachment2A,EOFEROShiftStaffing,EmergencyResponseOrganizationandShiftStaffing,(allpositionsshouldbefilled,exceptasauthorizedbytheRM).f.Ensurearrangementsforfood,water,andothernecessitiesaremadefornext48to72hours,ifnecessary.g.ArrangeforhotelreservationsandcarrentalsforincomingpersonnelasdirectedbytheRM.h.WorkwiththeRMforauthorizationfortheexpenditureoffunds.
REVISIONNo.:3PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:97of117ATTACHMENT16EOFADMINISTRATIVESUPERVISORCHECKLIST(Page3of3)C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1~Supervisedfacilitywalkthroughtoensurealldocuments,equipment,andsupplieswerereturnedtopre-activationconditionand/orlocation.2.ReturnedpositionnotebooktotheRMoffice.3.ProvidedallcompletedpaperworktotheRM.
REVISIONNO.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT17EOFADMINISTRATIVESTAFFCHECKLIST(Page1of3)PAGE:98of117NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.IdentifyavailabilitytotheEOFAdministrativeSupervisor.3.Verifyproceduresbypostingrevisionnumbersonthestatusboard.Postallprocedures(EPIP,HP,Chem).ConsultControlCopy1intheRecoveryManager'sOfficeorfollowthestepsbelowtoprintoutanEPIPlist.a.InLotusNotes,clickonthePSLProceduresIcon.b.OntheSearchlinetoolbar,clickthefarrightbutton(with2circlesandadownarrow).c.SelectGroupSearchfromthedropdownmenu.d.IntheSearchlinetype"EP"(wherethe"XX"is).e.ClickSearchorhitEnter.f.EPIPlistisnowdisplayed(notinanyparticularorder).g.Toprintthelist:ClickFile.SelectPrintfromthedropdownmenu.SelectViewOptionsinthedialoguebox.ClickOK.
REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:99of117EPIP-06ST.LUCIEPLANTATTACHMENT17EOFADMINISTRATIVESTAFFCHECKLIST(Page2of3)B.FACILITYOPERATIONAllphotocopiers,telecopiers,computers,printers,etc.energizedandproblemsreportedtoEOFAdministrativeSupervisor.2.Switchboardphonemanned.3.Establishlogforincoming/outgoingtelecopiers,usingAttachment17A,TelecopyLog.4.Stepstooccurcontinuallywhilethefacilityisinoperation:a.ProvideclericalsuppliestoallgroupsintheEOF,asneeded.b.Producerequired/requestedcopies,retainoriginals.c.Distributecopies,telecopies,etc.torecipientsasquicklyaspossible(e.g.,ERDADSdatasheets,notificationforms,newsreleases,etc.).d.ProvideanyincomingtelecopymaterialstotheRM,RMOPSAdvisor/Logkeeperorasdesignatedonthecoverpage.e.AssisttheEOFAdministrativeSupervisorinestablishing24hourstaffing.f.PerformdutiesassignedbytheEOFAdministrativeSupervisor.
REVISIONNO.:3PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT17EOFADMINISTRATIVESTAFFCHECKLIST(Page3of3)PAGE:100of117C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.Allphotocopiers,telecopiers,computers,printers,etc.de-energizedandproblemsreportedtoEOFAdministrativeSupervisor.2.Conductedfacilitywalkthroughtoensurealldocuments,equipment,andsupplieswerereturnedtopre-activationconditionand/orlocation.3.EOFphoneswitchboardsetto"nightcall"~4.ReturnedpositionnotebooktotheRMoffice.5.ProvidedcompletedpaperworktotheEOFAdministrativeSupervisor.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT17AEOFTELECOPYLOG(Page1of1)PAGE:101of117IncomingOutgoingPhoneNumber:Date:~Message¹DescriptionReceivedFromTimePagesReceivingOperator:
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:102of117ATTACHMENT18EOFEMERGENCYSECURITYMANAGERCHECKLIST(Page1of3)NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.IdentifyavailabilitytotheRM.g,3.EstablishcontrolstoensureallEOFpersonnelcomplywiththerequirementsoftheFitnessforDutyRule.4.Verifyoperabilityoftheintoxilyzer.5.EnsureEOFsecurityforceestablished.B.FACILITYOPERATIONEstablishaccesscontrolfortheEOFandEmergencyNewsCenter(ENC)~2.ContacttheTSCSecuritySupervisor.a.Establishresponsibility/protocolfornotificationofoff-siteauthoritiesregardingthestatusofsiteevacuation.3.InitiatetheSecurityLogbook.4.Stepstooccurcontinuallywhilethefacilityisinoperation:a.AdviseRMonsecurityrelatedmatters.b.ProvideliaisonfunctionbetweenlocallawenforcementandrescueagenciesandFPLforissuessuchas:1.Bombthreatsoractsofterrorism.
REVISIONNo.:3PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:103of117ATTACHMENT18EOFEMERGENCYSECURITYMANAGERCHECKLIST(Page2of3)B.FACILITYOPERATION(continued)4.(continued)b.(continued)2.Membersofthepublicorthemediaarrivingatthesite.INITIAL3.Siteegressandingress.4.Fireorrescue/medicalresponse.c.CoordinatesafeguardssuspensionwiththeTSCSecuritySupervisor.d.Monitorsiteaccountabilitystatus.e.InterfacewithNRCSafeguards/SecurityCoordinatorwhentheNRCSiteTeamarrivesattheEOF.f.Trackstatusofinjuredpersonneltakentoanoff-sitemedicalfacility(useAttachment18A,InjuredPersonReport).g.MaintaintheSecurityLogbook.C.FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.Allpaperworkcollected.2.Closedoutwiththelocallawenforcementagencies.3.ClosedoutSecurityLogbook.
REVISIONNo.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:104of117ATTACHMENT18EOFEMERGENCYSECURITYMANAGERCHECKLIST(Page3of3)C.FACILITYCLOSEOUTANDRESTORATION4.ReturnedpositionnotebooktotheRMoffice.5.ProvidedallcompletedpaperworktotheRM.6.Allaccessbadgesreturnedtopre-activationlocation.7.'acilitysweepcompleted.8.Facilitylockedandalarmset.INITIAL REVISIONNO.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT18AINJUREDPERSONREPORT(Page1of1)PAGE:105of117EMPLOYER:0FPL0OTHER(listcompanyname)JOBDESCRIPllON:TIMEINJURED:TIMEREPORTED:NATUREOFINJURY:LOCATIONWHEREINJURYOCCURRED:ISTHEVICTIMCONTAMINATED'0NODYESTRANSPORTEDTOHOSPITAL'WHATBODYPARTSCONTAMINATED?HOWTRANSPORTED2LEVELOFCONTAMINATIONAREALEVELDPMCPMAREALEVELDPMCPMAREALEVELDPMCPMNAMEOFHOSPITALOROTHERLOCATION0NOCIYESACllVITYATTHETIMEINJURYOCCURREDCURRENTMEDICALCONDmONMISC.INFO.NAME;EMPLOYER:0FPL0OTHER(Estcompanyname)JOSDESCRIPTION:TIMEINJURED:TIMEREPORTED:NATUREOFINJURY:LOCATIONWHERE(NJURYOCCURRED:0NO0YESTRANSPORTEDTOHOSPITAL?0NOOYESISTHEVICTIMCONTAMINATED2WHATBODYPARTSCONTAMINATED'?HOWTRANSPORTED?LEVELOFCONTAMINATIONAREALEVEIDPMCPMAREALEVEIDPMCPMAREALEVEIDPMCPMNAMEOFHOSPITALOROTHERLOCATIONACIIVITYATTHETIMEINJURYOCCURREDCURRENTMEDICALCONDmONMISC.INFO.
REVISIONNo.:3PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT19NUCLEARDIVISIONDUTYOFFICERCHECKLIST(Page1of2)PAGE:106of117NOTE1.ThefollowinginformationisprovidedwhenrespondingintheEOF.2.Whennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.B.FACILITYOPERATION1.InitiatetheEmergencyControlOfficer(ECO)Logbook.2.NotifyINPOthatanAlert(orhigher)emergencyclasswasdeclared.3.Stepstooccurcontinuallywhilethefacilityisinoperation:a.Maintain24hourperdayon-callavailability.b.ServeasatechnicaladvisorfortheECO.1.ServeasadvisortotheEIMontechnicalmattersthatmayaidintheformationofnewsreleases.2.ServeasadvisortotheGAM,RiskManager,ortoStateandCountyagenciesontechnicalmatters.3.MakenotificationsfortheECO,asdirected4.Serveas"interimECO,"intheEOFduringperiodsoftimewhentheECOleavesthefacility.
(I1 REVISIONNo.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT19NUCLEARDIVISIONDUTYOFFICERCHECKLIST(Page2of2)PAGE:107of117B.FACILITYOPERATION(continued)3.(continued)c.MaintainarecordoftheeventandactivitiesintheECOLogbook(useAttachment19A,TypicalInformationtobeIncludedintheECOLogbook)~d.RequestthatINPOassistFPLbyperformingthefollowing:1.Asrequested,submitpressreleasesoverNuclearNetwork.INITIAL2.PromptlyinformFPLofanymediainquiriesorindustryofferstoprovideassistancebycontactingyou(NDDO)intheEOF(orotherlocation)atyournumber.3.RecordallconversationswithINPOindetailintheECOLogbook.C.FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.TerminatedassistancetotheECO.2.Collectedallpaperwork,3.ClosedouttheECOLog,returnedtheLogbooktotheECOpositionnotebookoffice.4.ReturnedpositionnotebooktotheRMoffice.5.ProvidedallcompletedpaperworktotheRM.
REVISIONNO.:PROCEDURENOPROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:108of117EPIP-06ST.LUCIEPLANTATTACHMENT19ATYPICALINFORMATIONTOBEINCLUDEDINTHEECOLOGBOOK(Page1of1)Maintainingconcisedetailedlogsduringanemergencyeventisveryimportant.Followingtheevent,allinformationrecordedwillbeneededtoprovideaclearpictureofactionstaken.RegulatoryagencieswillusethisinformationtoevaluatetheadequacyofmitigativeandcorrectiveactionstakenbytheEmergencyResponders:ThefollowinginformationshouldbeincludedintheECOLogbook:Timeofeachentry.SummaryofanydirectionsgiventootherEmergencyResponders(ie.,whowastoldwhattodowhen).SummaryofdiscussionswithEmergencyManagers.SummaryofdiscussionswiththePresident-NuclearDivision.DonotremovepagesfromtheLogbook.
REVISIONNo.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT20EMERGENCYCONTROLOFFICERCHECKLIST(Page1of1)PAGE:109of117NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.B.FACILITYOPERATION1~Stepstooccurcontinuallywhilethefacilityisinoperation:a.Approvenewsreleases.b.ServeasofficialspokespersonfortheNuclearDivision.c.EnsuretheRMisawareoftheprimaryconcernsofthemedia/public.d.Actasthechiefnuclearofficer.e.KeeptheRMabreastofactivitiesinvolvingtheGovernmentalAffairsManagerandRiskManager,iftheyarenotintheEOF.f.Maintainawarenessofplantstatusandradiologicalconditions.C.FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.SpokespersonresponsibilitieshavebeenreturnedtoCorporateCommunications.2.ProvidedallcompletedpaperworktotheRM.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT21GOVERNMENTALAFFAIRSMANAGERCHECKLIST(Page1of2)PAGE:110of117NOTE1.Thefollowinginformationis,providedwhenrespondingintheEOF.2.Whennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.Verifythatthefollowingarenotified:a.GovAffairsRep(Tallahassee)b.Governor'sAdvisorc.GovernmentalAffairsAssistantd.AviationDepartmentB.FACILITYOPERATIONNOTETheliaisonfunctionbetweentheECOandpublicofficialsisaccomplishedbytheGAMinconjunctionwiththeGovernmentalAffairsAssistant,GovernmentalAffairsRepresentativeinTallahasseeandtheGovernor'Advisor.1.Stepstooccurcontinuallywhilethefacilityisinoperation:a.Shareinformationalupdates.b.ReferanyspecificquestionsorcommentsfromelectedorpoliticalauthoritiestotheECO.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT21GOVERNMENTALAFFAIRSMANAGERCHECKLIST(Page2of2)PAGE:111of117B.FACILITYOPERATION(continued)1~(continued)c.ReportsummariesofinterfacewithgovernmentalofficialsroutinelytotheECO.d.PromptlyreportrumorsthatcouldsignificantlyimpactemergencyresponsecapabilitytotheECO.e.Keepalogofallsignificantinformation.C.FACILITYCLOSEOUTANDRESTORATIONINITIAL1~Alloff-siteinterfaceshavebeendiscontinued.2.TurnoverandcloseoutprovidedtotheECOregardingliaisonactivitieswithoff-siteofficials.3.Allpaperworkcollected.4.AllcompletedpaperworkforwardedtoEmergencyPlanning.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT22EMERGENCYINFORMATIONMANAGERCHECKLIST(Page1of3)PAGE:112of117NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.ObtainanupdatefromtheECOorRM.3.Re-establishcontactwiththeEmergencyNewsCenter(ENC)Manager.4.Re-establishcontactwiththe"acting"EIM.5.Resumeresponsibilityforallcommunications,asappropriate.6.DeterminewhensufficientstaffispresenttohandleallfurthermediabriefingsfromtheENC.7.RecommendtotheECOthattheENCshouldbedeclaredoperational.OperationalatB.FACILITYOPERATION1.RequestthatclocksintheENCbesynchronizedwithEOF(basedonERDADS).2.IssueanewsreleaseannouncingoperationoftheENC,itslocationandthemediaphonenumber.3.EnsureaCountyTechnicalAdvisorisdispatchedtoSt.LucieandMartinCounties.4.DirectanEIM/ENCTechnicalAdvisortokeepLogbook.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT22EMERGENCYINFORMATIONMANAGERCHECKLIST(Page2of3)PAGE:113of117B.FACILITYOPERATION(continued)5.Stepstooccurcontinuallywhilethefacilityisinoperation:a.Whendevelopingupdates,subsequentstatementsand/ornewsreleases,obtainapprovalfromtheECO.b.CoordinatereviewswithState,CountyandFederalrepresentativesintheEOF.c.EnsurethatallFPLnewsreleasesaredeliveredtotheEOFAdministrativeStafffordistributiontotheappropriateagencies(includingtheCorporateCommunications(CC)staffinJunoBeach).d.EnsurethatallFPLnewsreleasesaredeliveredtotheENCandsharedamongtheparticipantsinthejointnewscenterpriortobriefings.e.Conductnewbriefings(useAttachment22A,NewsBriefingGuidelines,tothisattachment).f.AttendEOFbriefingsandmeetings,especiallythosecalledtodetermineStateandCountyProtectiveActionRecommendations(PARs)ifpossible.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT22EMERGENCYINFORMATIONMANAGERCHECKLIST(Page3of3)PAGE:114of117C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAsnecessary,continuedinterfacewiththemediashouldbeinaccordancewithstandardCorporateCommunicationsprocedures.NOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.MedianotifiedofENCdeactivation.2.ENCreturnedtopre-activationcondition.3.CountyTechnicalAdvisorsrecalled.4.ProvidedallcompletedpaperworktotheRM.
REVISIONNo.:3PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT22ANEWSBRIEFINGGUIDELINES(Page1of1)PAGE:115of117NOTETheseguidelinesaretakenfromtheCorporateCommunicatIonsNuclearEmergencyPlan(CCNEP).Foradditionalinformation,theCCNEPshouldbeconsulted.1.IncoordinationwiththeENCManager,scheduleandmoderatemediabriefingsintheENCMediaBriefingRoom.2.ThesebriefingsshouldbeproceededbyabriefingintheENCtodeterminethefollowing:A.WhohasannouncementsB.WhattheannouncementsareC.Whatprioritytheyshouldbein3.Briefingsshouldbeconductedeveryhour.4.UsetheECO,otherFPLdecisionmakers,FPLtechnicalstaffandrepresentativesfromState,CountyandFederalemergencyagenciesasspokespersons.5.UseFPL'stechnicaladvisorstoconductbackgroundbriefingsbetweennewsbriefings,asappropriate.6.Duringthebriefing,referthemedia'squestionstotheagencyhavingjurisdictionofthesubjectofthequestion.
REVISIONNo.:3PROCEDURENo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:116of117EPIP-06ST.LUCIEPLANTATTACHMENT23EIM/ENCTECHNICALADVISORCHECKLIST(Page1of2)NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONIRefertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.INITIALB.FACILITYOPERATION1~InitiatetheEIMLogbook.2.Stepstooccurcontinuallywhilethefacilityisinoperation:a.GatherinformationandensuretheEIMisup-to-dateontheemergencystatusinthefollowingareas:EmergencyClassificationsCorrespondingEmergencyActionLevels(EALs)AssociatedProtectiveActionRecommendations(PARs)Plantconditionsandparametersb.AssisttheEIMwithinterpretingtechnicaldatatoensureaccuracyofnewsreleases.c.AssistinobtainingdatafromtheEOFstaffforuseinnewsreleases,asneeded(payparticularattentiontoupdatesofradiologicalinformationthroughdoseassessment).
REVISIONNO.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT23EIM/ENCTECHNICALADVISORCHECKLIST(Page2of2)PAGE:117of117B.FACILITYOPERATION(continued)2.(continued)d.Verifythatyouareontheroutinglistsforthefollowinginformation:INITIALHP/ChemistrydataETM/ERDADSupdatesNuclearlicensing/communicationsdatae.Reviewcontentofnewsreleasesfortechnicalaccuracy.f.EnsurethattheENCisreceivingaccurate,up-to-dateinformationneededformediabackgrounders.g.Conducttechnicalbriefings,asrequested.C.FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.AssistedEIMinENCcloseout.2.Returnedalldocuments,equipmentandsuppliestopre-activationconditionand/orlocation.3.ClosedouttheEIMLog,returnedLogbooktotheEIMpositionnotebook,andreturnedthenotebooktotheRMoffice.4.ReturnedpositionnotebooktoRMoffice.5.ProvidedallcompletedpaperworktotheEIM.
Title:FPLST.LUCIEPLANTEMERGENCYPLANIMPLEMENTATIONPROCEDURESAFETYRELATEDProcedureNo.EPIP-08CurrentRevisionNo.EffectiveDate01/23/01OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSResponsibleDepartment:EMERGENCYPLANNINGREVISIONSUMMARY:Revision2-AddednewNRCNotificationformandrevisedtitleofformthroughoutprocedure.ClarifiedturnoverresponsibilitiesbetweenECandRM.DeletedECturnoverguidance(includinginECprocedure).ImprovedoverviewinformationregardingPARs.AddedreferencetoNUREG-1022.Clarifiedinstructionsfordetermining"timecontactmade."AddednotesidentifyingtheavailabilityofinformationfromprintoutsoftheClassAmodeltoassistincompletionofoff-sitenotificationforms.UpdateddirectionsforcompletionofNRCNotificationForm.Madeadministrative/editorialchanges.(R.Walker,01/18/01)Revision1-THISPROCEDUREHASBEENCOMPLETELYREWRITTEN.Addeddefinition,instructionsectionandaddedguidanceonpreparingthesupplementaldatasheet.RemovedECorRMsignaturefromthePARworksheets,deletedcautionandinstructionstoreviewpreviouslyissuedPARSandmadethesupplementaldatasheetarequireddocumentfornotificationswith60-minutetimelimits.(S.Knapp,09/11/00)Revision0-Thisprocedureprovidesinformationandinstructionsfortoff-sitenotificationsandProtectiveActionRecommendations(PARS).(SteveKnapp,05/31/00)ecomletionofPSLPROCEDUREPRODUCTIONRevision2FRGReviewDate01/17/01RevisionFRGReviewDate005/30/00ApprovedByR.G.WestPlantGeneralManagerApprovedByR.G.WestPlantGeneralManagerN/ADesignatedApproverN/ADesignatedApprover(MinorCorrection)ApprovalDate05/31/00ApprovalDate01/18/01SOPSDATEDOCTPRQGEDUREDOCNEPIP-08SYSCOMcoMPLETEDITM2
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTTABLEOFCONTENTSPAGE:2of66SECTION1.0PURPOSEPAGE
2.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTS...83.0RESPONSIBILITIES4.0DEFINITIONS5.0INSTRUCTIONS.105.1StateandCountyNotification.115.2NuclearRegulatoryCommission(NRC)Notification......~~~~.~~~...~........14APPENDICESAPPENDIXANOTIFICATIONSFROMTHEAFFECTEDCONTROLROOM....15APPENDIXBNOTIFICATIONSFROMTHETECHNICALSUPPORTCENTER(TSC).APPENDIXCNOTIFICATIONSFROMTHEEMERGENCYOPERATIONSFACILITY(EOF).2336 REVISIONNO.:PROCEDURENO.:EPIP-08SECTIONPROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTTABLEOFCONTENTS(continued)PAGE:3of66PAGEATTACHMENTSATTACHMENT1PRIMARYEMERGENCYCOMMUNICATIONSSYSTEMS...49ATTACHMENT2FLORIDANUCLEARPLANTEMERGENCYNOTIFICATIONFORM.52ATTACHMENT2ASUPPLEMENTALDATASHEET.53ATTACHMENT2BDIRECTIONSFORCOMPLETINGTHEFLORIDANUCLEARPLANTEMERGENCYNOTIFICATIONFORM.....54ATTACHMENT2CDIRECTIONSFORCOMPLETINGTHESUPPLEMENTALDATASHEET.......60ATTACHMENT3NRCREACTORPLANTEVENTNOTIFICATIONWORKSHEET.ATTACHMENT3ADIRECTIONSFORCOMPLETINGTHENRCREACTORPLANTEVENTNOTIFICATIONWORKSHEET........~.......6365 REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:4of661.0PURPOSE1.1Discussion1~Thisprocedureprovidesinformationandinstructionsforthecompletionofoff-sitenotificationsandProtectiveActionRecommendations(PARS).2.3.4.ThisprocedureisapplicabletobothUnit1andUnit2.ThisprocedureisforuseintheControlRoom,TechnicalSupportCenter(TSC)andEmergencyOperationsCenter(EOF).UponinitialDeclarationofanemergencyclassificationtheNPSassumesthedutiesoftheEmergencyCoordinator(EC).TheECpositionremainsinitiallyintheaffectedControlRoomandthentransferstotheTechnicalSupportCenter(TSC)iftheTSCgoesOperational.TheTSCisrequiredtobeactivatedatanAlertorhigherEmergencyClass.ThedutiesoftheECareturnedovertoanECqualifiedmemberofplantmanagementwhentheTSCgoesOperationalinaccordancewithEPIP-02,DutiesAndResponsibilitiesOfTheEmergencyCoordinator.OncetheEOFisoperationalandproperturnoverhasbeenconducted,theRecoveryManager(RM)assumesresponsibilityforoff-sitenotificationsto'theStateandlocalauthoritiesandtheNRC.TheRMalsoassumesresponsibilityforrecommendingoff-siteprotectiveactions.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:5of661.1Discussion(continued)6.ThefollowingtableillustrateswhichfacilityhasaresponsibilityforClassification,Notification'rPARs.ClassificationsNotificationsControlRoom(XuntilECfunctiontransferstotheTSCXtransfers->Xtransfers->TSCEOF(Xwhenoperational)(Xwhenoperational)XXtransfersmPARsXtransfers->Xtransfers->X7.Off-siteNotificationA.PurposeofOff-SiteNotificationsFPLisrequiredtonotifyoff-siteagenciesintheeventofanyemergencythatcouldthreatenthehealthandsafetyofthepublic.Thesenotificationsprovideanearlywarningtoagenciesresponsibleforpublicprotection.WhoShallBeNotifiedStateDivisionofEmergencyManagementStateDepartmentofHealth(BureauofRadiationControl)St.LucieCountyEmergencyOperationsCenterMartinCountyEmergencyOperationsCenterNRCNOTETheStateDepartmentofHealth(BureauofRadiationControl)maynothavetheirofficestaffedona24-hourbasis.IntheeventthattheydonotanswertheHotRingDown(HRD)telephone,theStateWarningPointassumesresonsibilitfornotifintheirdutofficer.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:6of661~1Discussion(continued)7.B.(continued)StateandLocalAgenciesarenotifiedbyusingtheHotRingDown(HRD)telephone.TheHRDringstheStateWarningPoint.TheStateWarningPointputstheotheragenciesonlineand,reducestheneedforindividualcalls.TheNRCisnotifiedusingtheEmergencyNotificationSystem(ENS)telephone.SeeAttachment1forinformationaboutPrimaryEmergencyCommunicationsSystems.2.3.g4AftertheStateCoordinatingOfficerarrivesintheEOF,he/shecantransfer"NETControl"totheEOF.Whenthisoccurs,theRecoveryManager'sbriefingbecomestheprimarynotificationmethodfortheStateandCounties.TheFloridaNuclearPlantEmergencyNotificationForm(formsimilartoAttachment2)andtheSupplementalDataSheet(formsimilartoAttachment2A)shouldstillbecompletedandprovidedtotheStateCoordinatingOfficerorhis/herdesigneeintheEOF.CallsbyFPLpersonnelovertheHotRingDowntelephoneshouldnolongerbemade.NRCnotificationsoccurthroughanopenlineofcommunicationintheTSCand,whenoperational,theEOF.8.ProtectiveActionRecommendationsA.ProtectiveactionsforthegeneralpublicareordinarilyNOTrequiredpriortodeclarationofaGeneralEmergency.Itispossiblehowever,thatduetounusuallystableandconstantmeteorologicalconditions,protectiveactionscouldberecommendedataSiteAreaEmergencybasedonprojecteddoses.Thisistheexceptionratherthantherule.ProtectiveactionsforthegeneralpublicarerequiredtoberecommendedifaGeneralEmergencyisdeclared.InitialProtectiveActionRecommendations(PARs)arenormallybasedonplantconditions.ThiswouldNOTbetrueiftheGeneralEmergencywasdeclaredbasedonoff-sitedose(eithermeasuredorprojected)oraSecurityEmergency(pertheSecurityPlan).ThepredeterminedminimumPARs(basedonplantconditions)areasgivenbelow.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:7of661.1Discussion(continued).8.(continued)B.GeneralEmergency-MinimumPARsInanycasewhereaGENERALEMERGENCYhasbeendeclared,theminimumPARshallbe:2.Shelterallpeoplewithina2-mileradiusandoutto5milesinthesectorsaffected.(Sectorsaffectedareatleastthree,includingthedownwindsectorplusthetwoadjacentsectors.)IfaGENERALEMERGENCYhasbeendeclaredduetoactualorprojectedseverecoredamage,theminimumPARshallbe:3.Evacuateallpeoplewithina2-mileradiusfromtheplantandoutto5milesinthesectorsaffected.Shelterallpeopleintheremainingsectorsfrom2to5milesandfrom5to10milesformtheplant.IfaGENERALEMERGENCYhasbeendeclaredduetolossofphysicalcontroloftheplanttointruders,includingtheControlRoomoranyotherarea(s)vitaltotheoperationofthereactorsystem(asdefinedintheSecurityPlan),theminimumPARshallbe:Evacuateallpeoplewithina2-mileradiusfromtheplantandoutto5milesinthesectorsaffected.Shelterallpeopleintheremainingsectorsfrom2to5milesandfrom5to10milesfromtheplant.C.Onceareleaseofradioactivematerialoccurs,doseassessmentshouldbeutilizedwhenevaluatingPARs.ThefinaldeterminationofthePARshouldconsiderallavailableinformationincludingoff-sitedoseprojections,plantconditionsandfieldmonitoringdata.Themostconservativerecommendationshallbemade.IfitisanticipatedthataPARthresholdwillbeexceeded,DONOTwaituntilthethresholdisexceededtomakethatPAR.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:8of6
62.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTSNOTEOneormoreofthefollowingsymbolsmaybeusedinthisprocedure:gIndicatesaRegulatorycommitmentmadebyTechnicalSpecifications,ConditionofLicense,Audit,LER,Bulletin,OperatingExperience,etc.andshallNOTberevisedwithoutFacilityReviewGroupreviewandPlantGeneralManagerapproval.Indicatesamanagementdirective,vendorrecommendation,plantpracticeorothernon-regulatorycommitmentthatshouldNOTberevisedwithoutconsultationwiththeplantstaff.'PIndicatesastethatreuiresasinoffonadatasheet.2.1References1.St.LuciePlantUpdatedFinalSafetyAnalysisReport(UFSAR)Unit1andUnit22.St.LuciePlantTechnicalSpecificationsUnit1andUnit23.gSt.LuciePlantRadiologicalEmergencyPlan(E-Plan)4.E-PlanImplementingProcedures(EPIP-00-13)5.Ql-17-PSL-1,QualityAssuranceRecords2.2RecordsRequired1.AllPARworksheetsandnotificationsforms(Attachment2and2A)shallbemaintainedinplantfilesinaccordancewithQI-17-PSL-1.2.3CommitmentDocumentsPMAIPM96-04-165,"ITR96-006"(UnusualEventDeclaredDuetoDroppedRod)2.3.4.PMAIPM96-09-185,ConditionReportCR-96-1750(Off-siteNotificationUsingCommercialPhone)tt3NRCInspectionReport91-01,ClosureofIFls89-31-03and89-31-01g4ConditionReportCR-00-0428(EvaluatedExerciseCritique)(continuedonnextpage)
REVISIONNO.:PROCEDURENo.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:9of662.3CommitmentDocuments(continued)5.gsPMAIPM96-05-233(Off-siteNotificationProcess)6.f[rPMAIPM99-09-016(PARsBasedonFMTData,CompletionofNRCNotificationForm)7.$8NUREG-1022,EventReportingGuidelines10CFR50.72and50.73,Section4.2.4,ENSEventNotificationWorksheet(NRCForm361).3.0RESPONSIBILITIES3.1EmergencyCoordinator-ResponsibleforClassifications,NotificationsandPARs.3.2RecoveryManager-ResponsibleforNotificationsandPARs.3.3DutyCallSupervisor-AssistsECwithformsandnotifications.3.4TSCECAssistant/LogkeeperorTSCOPSCoordinator-PreparesnotificationformsforECapprovalwhentheTSCisoperational.3.53.6EOFRMOPSAdvisor-PreparesnotificationformsforRMapprovalwhentheEOFisoperational.TSCHRDCommunicator-AssistsTSCECAssistant/LogkeeperorTSCOPSCoordinatorwithformpreparationandmakescallstocompletenotifications.3.7EOFHRDCommunicator-AssistsEOFRMOPSAdvisorwithformpreparationandmakescallstocompletenotifications.3.8TSCChemistrySupervisor(inhisabsence,TSCDoseAssessor)-AssistsECwithradiologicaldoseassessmentdataandPARS.3.9HPManager(inhisabsence,EOFDoseAssessor)-AssistsRMwithradiologicaldoseassessmentdataandPARS.3.10LicensingManager-OverseesEOFcommunicationsperformedbyHRDCommunicator,ENSCommunicator,HPNCommunicatorandTSCCommunicator.
REVISIONNO.:PROCEDURENo.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:10of664.0DEFINITIONS4.14.24.34.44.5Conservative-Meansmoreextensiveorcomprehensiveactionunderagivensetofcircumstancestoprovideagreatermeasureofsafety.Forexample,evacuationismoreconservativethansheltering.Emergency-Anyoff-normaleventorconditionwhichisclassifiedintooneofthefoureventcategories(UnusualEvent,Alert,SiteAreaEmergency,orGeneralEmergency)bytheNPSinaccordancewithEPIP-01,ClassificationofEmergencies.EmergencyCoordinator-ThetitleassumedbytheNPS,untilrelievedbyplantmanagementthroughproperturnover,intheeventofplantconditionsthattriggertheEmergencyPlan.TheEmergencyCoordinator(EC)isresponsiblefornotifyingoff-siteauthorities,emergencyrespondersbothinsideandoutsidethecompany,andhasfullauthorityandresponsibilityforon-siteemergencyresponseactions.TheECisalsoresponsibleforProtectiveActionRecommendationsduringtheinitialstagesofanemergency.FloridaNuclearPlantEmergencyNotificationForm=StateNotificationForm(SNF).Operational(statusforanemergencyfacility)-Themandatoryminimumstaffispresentandthefacilityhastakenresponsibilityforitsprocedurallyassignedfunctions.4.64.74.8ProtectiveActionRecommendations(PARs)-Recommendations,foractioninstructionstoprotectthepublic,madebytheEmergencyCoordinatororRecoveryManagertoStateandCountyofficials.FPLmayrecommendNoAction,ShelteringorEvacuation.RecoveryManager(RM)-Adesignatedcompanyofficerorseniormanager,whowillhaveresponsibilityforthedirectionandcontroloftheEOF.He/shehastheauthoritytoestablishpolicyandtoexpendfundsnecessarytocopewithemergencysituationsthattriggertheimplementationoftheEmergencyPlan.Release(duringanydeclaredemergency)1.Anyeffluentmonitorincreaseof(approximately)10timesoronedecadeabovepre-transientvalues.OR2.HealthPhysicsdetectingairborneradioactivitylevelsinexcessof25%derivedairconcentration(DAC)outsideofplantbuildingsduetofailureofequipmentassociatedwiththedeclaredemergency.
REVISIONNO.:PROCEDURENo.:EPIP-08PROCEDURETITLEOFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:11of665.0INSTRUCTIONS5.1StateandCountyNotificationTimeLimitsA.Notificationshallbeinitiatedwithin15minutesofanyofthefollowing:RecognitionofentryintotheEmergencyPlan.2.EscalationinEmergencyClass.3.4.De-escalationoftheEmergencyClass.ProtectiveActionRecommendation.5.ChangeinProtectiveActionRecommendation.B.Notificationshallbeinitiatedwithin60minutesofanyofthefollowing:2.3.AtanAlertorhigherEmergencyClass,thetimeofthelastupdate(unlessadifferentfrequencyhasbeenagreedtobytheoff-siteagenciesasduringahurricane).Aradiologicalreleasehasbeeninitiated.Aradiologicalreleasehasbeenterminated4.5.Asignificantchangeinplantconditionshasoccurred(e.g.,lossorrestorationofoff-sitepowerormajorplantequipment).Terminationoftheemergency.
REVISIONNO.:PROCEDURENOEPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:12of665.1State,andCountyNotification(continued)2.FormsRequiredforNotificationsCAUTIONNotificationsrequiretheuseofaformsimilartoAttachment2,FloridaNuclearPlantEmergencyNotificationForm(SNF)~TheSupplementalDataSheetshallonlbetransmittedwithanewlcornletedSNF.A.Notificationswith15minutetimelimitsshallbemadeusingaformsimilartoAttachment2,FloridaNuclearPlantEmergencyNotificationForm.NOTETheSupplementalDataSheet(Attachment2A)isNOTintendedforusebytheControlRoomandshouldNOTbepreparedbyortransmittedfromthatfacilit.B.C.AformsimilartotheSupplementalDataSheet(Attachment2A)shouldalsobepreparedandtransmittedwiththeSNF.Itispermissibletoprepareandtransmitthe"PlantConditionsInformation"sectiononly.Notificationswith60minutetimelimitsshallbemadeusingaformsimilartoAttachment2,FloridaNuclearPlantEmergencyNotificationForm,andaformsimilartotheSupplementalDataSheet(Attachment2A).Itispermissibletoprepareandtransmitthe"PlantConditionsInformation"sectiononly,whendoseassessmentdataisunavailable.3.Specialinstructionsduetoextraordinarycircumstances.A.IfEmergencyClassescalationisnecessaryduetorapidlydegradingconditionsandthetransmissionoftheSNFhasNOTbeeninitiated,Thenanewnotificationformshouldbefilled-outdescribingthelatestEmergencyClassandconditions,butalsoincludingreferencetotherapidescalationthroughthelowerclassification(e.g.,the"AdditionalInformationorUpdate"sectionoftheformshouldincludeastatementsimilarto"ReactorCoolantSystemleakagehadincreasedrapidlyanddidnotallowforseparatenotificationofanUnusualEvent")~OR REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:13of665.1StateandCountyNotification(continued)3.A.(continued)2.thetransmissionofacompletelyfilled-outandapprovedSNFisunderway,ThenprovidetheStateandCountyauthoritieswiththeinitialnotificationinformationbytransmittinglines1-6,ataminimum,oftheSNFandterminatethephonecallbystatingthatanewnotificationformwillbeprovidedwithin15minutes.B.C.IfoneUnitisinaclassifiedeventandthesameortheotherUnitentersintoaneventwherethesameorlesserEmergencyClasswouldapply,ThenanewclassificationshouldNOTbedeclared.TheeventshouldbedocumentedonaSNFas"AdditionalInformationorUpdate"andissuedassoonaspracticable.IfoneUnitisinaclassifiedeventandtheotherUnitentersintoamoresevereeventinwhichahigherEmergencyClasswouldapply,Thenthenewclassificationshallbedeclaredandpromptly,withintheregulatorytimelimits,issuedtotheState,CountiesandtheNRC.ENDOFSECTION5.1 REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLEOFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:14of665.2NuclearRegulatoryCommission(NRC)NotificationTimeLimitsNOTENtiltstfltNRGii*p1dpitIfttiltsillifSttandlocalagencies.Theone-hourtimelimitin10CFR50.72(a)(3)istoensuretimelyNRCnotificationincaseswherenotificationofStateandlocalaenciesisdelaedorroloned.A.ThelicenseeshallnotifytheNRCimmediatelyafternotificationoftheappropriateStateorlocalagenciesandnotlaterthanonehourafterthetimethelicenseedeclaresoneoftheEmergencyClasses(10CFR50.72(a)(3))~2.SpecialInstructionsA.InitialnotificationtotheNRCusingtheEmergencyNotificationSystem(ENS)(usuallydonefromtheControlRoom)shoulduseAttachment3,NRCReactorPlantEventNotificationWorksheet.B.AtanAlertorhigherEmergencyClass,theNRCwillwanttoestablishanopenlineofcommunicationwiththeControlRoom,utilizinganENSconferencebridgetyinginthelicenseewithNRCHeadquartersandRegionpersonnel.OncetheTechnicalSupportCenter(TSC)isoperational,theControlRoomshouldtransferresponsibilityforNRCcommunicationstotheTSC.C.D.E.TheEmergencyOperationsFacilityshouldjointheTSContheENSconferencebridgeandtaketheleadforNRCcommunications.TheTSCandEOFshouldalsoutilizetheHealthPhysicsNetwork(HPN)lineinamannersimilartotheENS.BoththeENSandHPNCommunicatorsinbothfacilitiesshouldkeeplogsofinformationtransmittedandreceivedfromtheNRCinaccordancewithprocedures.ENDOFSECTION5.2 REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:15of66APPENDIXANOTIFICATIONSFROMTHEAFFECTEDCONTROLROOM(Page1of8)TheEChasresponsibilityfornotificationsandPARs.TheDutyCallSupervisor(DCS),orotherpersonnelintheControlRoomdesignatedbytheEC,shallassist.WhentheTSCbecomesoperational,TSCpersonneltakeoverthisfunction.TheDCSshouldprovidetheECwithdocumentationofanynotificationsmadefromtheControlRoom.TheDutyCallSupervisorshouldmakeamentalnoteofthetimewhenthenotificationisdueandensurethatitisdonewithin15minutesofclassification.~Off-siteCommunicationContentandProtocol1~PreparetheFloridaNuclearPlantEmergencyNotificationForm(formsimilartoAttachment2ofthisprocedure).TheSupplementalDataSheet(formsimilartoAttachment2A)isnotforuseintheControlRoom.2.Itshouldbeclearfromthe"ReasonForEmergencyDeclaration"whichEmergencyActionLevel(EAL)requiredtheemergencydeclaration.Wordingshouldbenon-technicalwithnoacronymsorabbreviations(e.g.,reactorcoolantpumpinsteadofRCP).3.DeterminingDownwindSectorsAffectedA.WinddirectioncanbeobtainedfromERDADSbydepressingthe"EPIP"key,onthetoprowofthekeyboard.TheMetTowerIndicatorPanelintheUnit1ControlRoomisanalternatesource.B.Iftheindicationisgreaterthan360'hewinddirectionisdeterminedbysubtracting360'romtheindicatednumber.Winddirectionshouldberoundedtothenearestwholenumber.C.Winddirectionisalwaysgivenas"windfrom."(Aneasterlywind,orwinddirection90',meansthatthewindisblowingfromeasttowest).D.Whendeterminingthesectorsaffected,theadjacentsectorsonbothsidesoftheactualdownwindsectorareincluded.Threesectorswilltypicallybelisted.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:16of66APPENDIXANOTIFICATIONSFROMTHEAFFECTEDCONTROLROOM(Page2of8)3.(continued)E.Ifthewindislocatedontheedgeofasector(i.e.,11',33',etc.),anadditional(fourth)sectorshouldbeadded.WindFromSectorsAffectedWindFromSectorsAffectedWindFromSectorsAffected348-11HJK11-33JKL33-56KLM56-78LMN78-101MNP101-123NPQ123-146PQR146-168QRA168-191RAB191-213ABC213-236BCDThereisno"0"sector236-258CDE258-281DEF281-303EFG303-326FGH326-348GHJThereisno"I"sector4.PARsBasedonPlantConditions.CAUTIONIfareleaseoccurs,notifytheECthatadoseassessorisrequiredandfollowtheEC'sdirectionsforPARs.TheECshouldusetheguidanceinAppendixBofthisprocedurefordeterminingPARsintheeventofarelease.A.BeginningatthetopleftofthePARflowchartbelow,answertheGeneralEmergencyquestion.B.IftheemergencyisnotaGeneralEmergency(GE),andthereisnorelease,"UtilityRecommendedProtectiveActions"areNONE.IfitisaGE,continueusingtheflowchart.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:17of66APPENDIXANOTIFICATIONSFROMTHEAFFECTEDCONTROLROOM(Page3of8)4.(continued)C.UsetheappropriateanswertoeachquestiontocontinueuntilyoureachoneofthetwoboxesthatprovidePARinformationbasedonplantconditions.GeneralEmergency?IftheemergencyisnotaGeneralEmergency,andthereisnorelease,"UtilityRecommendedProtectiveActions",areNONE.YeeIActualorProjectedSevereCoreDamage?II<AeILossofPhysicalControlofPlant?II'MILESNOACTIONEVACUATESHELTER0-2NoneNoneAll2-5AllRemainingNone(SectorsAffected)5-10AllNoneNoneYeeIMILESNOACTIONEVACUATES}IELTER0-2NoneAllNone2-5None(SectorsAffected)AllRemaining5-10NoneNoneAllNotes1.Severecoredamageisindicatedby:-Lossofcriticalfunctionsrequiredforcoreprotection(e.g.,lossofinjectionwithLOCA)OR-Highcoretemperatures(validCETgreaterthan700')OR-CHRRMreadinggreaterthan4.2E4R/hr.2.LossofphysicalcontrolofControlRoomorvitalreactoroperatingareastointruders.(PIEPIEPIP~-F-APPENA.R0/D.TransferthecorrectPARsinformationtotheFloridaNuclearPlantEmergencyNotificationFormusingtheactuallettersofthesectorsaffectedwhere"(SectorsAffected)"isindicatedintheflowchart'sPARsbox.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:18of66APPENDIXANOTIFICATIONSFROMTHEAFFECTEDCONTROLROOM(Page4of8)INITIAL5.Off-siteCommunicationProtocolCAUTION~g~Iferroneousinformationistransmittedtooff-siteagenciesandtheerrorisdiscoveredpriortoeventtermination,acorrectionshouldbeprovidedinanupdate.Theneedforandurgencyofprovidingtheupdateisdependentupontheimportanceoftheerror.~g~Iferroneousinformationistransmittedtooff-siteagencies,andtheerrorisdiscoveredaftereventtermination,theLicensingDepartmentshouldbeconsultedtodeterminetheneedandmethodforcontactingtheoff-siteagencieswithcorrectedinformation.~g3AnewFloridaNuclearPlantEmergencyNotificationFormshallbecornletedforalludates.A.B.C.ObtaintheEmergencyCoordinator(EC)Approvalsignaturepriortoanyoff-sitecommunication.UsingtheStateHOTRINGDOWN(HRD)Phone,dial100.Holddownthebuttononthehandsetwhiletalking.Thismustbedoneeachtimeyoutalk.Releasethebuttoninordertolisten.WhentheStateanswers,announce"ThisisSt.LucieNuclearPlant[asapplicable(Unit1,2)]withanemergencydeclaration.IamstandingbytotransmitFloridaNuclearPlantEmergencyNotificationForminformationwhenyouarereadytocopy."AllowtheStateWarningPointtocontactSt.LucieCounty,MartinCountyandtheBureauofRadiationControlpriortotransmittingtheinformationfromtheFloridaNuclearPlantEmergencyNotificationForm.Whenthepartiesareonline,providetheinformationslowlyanddeliberatelywithtimeforthedutyofficerstowritethedata.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:19of66APPENDIXANOTIFICATIONSFROMTHEAFFECTEDCONTROLROOM(Page5of8)INITIAL(continued)D.AlternateCommunicationsifHotRingDownisnotAvailable(IfHRDisused,skiptosectionE,NRCNotification).1.Alternate1-CommercialPhoneNOTEUseofthecommercialtelephoneasanalternatenotificationmethodrequirescallbackverificationfromtheStateWarningPoint.UseofESATCOMorLocalGovernmentRadioasanalternatenotificationmethodshouldincludeacallbackverificationnumberifavailable(e.g.,cellularhone.a.CalltheStateWarningPointusingthephonenumberintheSt.LuciePlantEmergencyResponseDirectory(ERD).Announce"ThisisSt.LucieNuclearPlant[asapplicable(Unit1,2,TSCorEOF)]withanemergencydeclaration.MycallbacknumberisC.Hangupthephoneandstandbyforthecallback.WhentheStateWarningPointgivesthego-ahead,providetheinformationfromtheFloridaNuclearPlantEmergencyNotification,Form.RequestcallbackfromtheStateWarningPointtoverifythattheynotifiedSt.LucieCounty,MartinCountyandtheBureauofRadiationControl.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:20of66APPENDIXANOTIFICATIONSFROMTHEAFFECTEDCONTROLROOM(Page6of8)5.D.(continued)2.Alternate2-ESATCOMINITIALNOTEUseESATCOMonlifAlternate1-commercialhoneisnotavailable.C.d.Holddownthe"push-to-talk"buttononthehandsetandwait3-5secondstohearabeepbeforeyoustarttalking.Thismustbedoneeachtimeyoutalk.Announce"StateWarningPoint,thisisSt.LucieNuclearPlant[asapplicable(Unit1,2,TSCorEOF)]withanemergencydeclaration."Thenreleasethe"push-to-talk"buttoninordertolisten.WhentheStateWarningPointacknowledges,announce"StateWarningPoint,thisisSt.LucieNuclearPlant[asapplicable(Unit1,2,TSCorEOF)]declaringp1(I'IamstandingbytotransmitFloridaNuclearPlantEmergencyNotificationForminformationwhenyouarereadytocopy.WhentheStateWarningPointgivesthego-ahead,providetheinformationfromtheFloridaNuclearPlantEmergencyNotificationForm.Announce"St.Lucieclear"attheendoftheconversation.
REVISIONNo.:PROCEDURENo.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:21of66APPENDIXANOTIFICATIONSFROMTHEAFFECTEDCONTROLROOM(Page7of8)5.D.(continued)INITIALNOTEUaelocalgovernmentradioonlyifAlternate1andAlternate2arebothunavailable.LGRcommunicationscanbemadewithSt.LucieCountyandMartinCountyEmergencyOperationsCenters(EOCs)whowillrelaytotheStateWarninPointandtherelatotheBureauofRadiationControl.3.Alternate3-LocalGovernmentRadioagb.C.d.Onchannel2,contactthecountyEOCsbyholdingdownthepush-to-talkbuttonandannouncing"St.LucieCountyEOC,thisisSt.LucieNuclearPlant[asapplicable(Unit1,2,TSCorEOF)]withanemergencydeclaration.Over."Thenreleasethe"push-to-talk"buttoninordertolisten.WhenSt.LucieCountyreplies,directthemtostandbywhileyoucontactMartinCounty.Whenbothcountiesareonline,announce"MartinandSt.LucieCountyEOCs,thisisSt.LucieNuclearPlant[asapplicable(Unit1,E,yggEogtldII~ttf2I~If.ItdtggyttransmitFloridaNuclearPlantEmergencyNotificationForminformationwhenyouarereadytocopy.Over."Whenthecountiesgivethego-ahead,providetheinformationfromtheFloridaNuclearPlantEmergencyNotificationForm.RequestSt.LucieCounty(iftheyareunable,MartinCounty)callbacktoverifythattheynotifiedtheStateWarningPointandtheBureauofRadiationControl.e.Endtheconversationbyannouncing"ThisisSt.LucieNuclearPlant[asapplicable(Unit1,2,TSCorEOF)],KNGR874,overandout."
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:22of66APPENDIXANOTIFICATIONSFROMTHEAFFECTEDCONTROLROOM(Page8of8)5.(continued)E.'NRCNotificationINITIALNOTENotificationoftheNRCisexpectedimmediatelyafternotificationofStateandlocalagencies.Theonehourtimelimitin10CFR50.72(a)(3)istoensuretimelyNRCnotificationincaseswherenotificationofStateandlocalagenciesisdelayedorprolonged.TheinitialcontactwiththeNRCwillincludeuseoftheNRCReactorPlantEventNotificationWorksheet(Attachment3).TheDutyCallSupervisor(DCS),orotherpersonnelintheControlRoomdesinatedbtheEC,maassistwiththisfunction.1.PreparetheNRCReactorPlantEventNotificationWorksheet.3.ObtainECapproval.NotifytheNRCviatheEmergencyNotificationSystem(ENS)telephoneimmediatelyafternotificationoftheappropriateStateorlocalagenciesandnotlaterthanonehourafterthetimethelicenseedeclaresoneoftheEmergencyClasses(10CFR50.72(a)(3))~TheNRCEmergencyNotificationSystem(ENS)istheprimarycommunicationspathwaytotheNRC.Initiatecontactbydialing(direct,noaccesscodeneeded)oneofthephonenumbersprovidedonthephoneorintheERD.ThiswillbecomeanopenlineofcommunicationattheAlertorhigheremergencyclass.ENDOFAPPENDIXA REVISIONNO.:PROCEDURENo.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:23of66APPENDIXBNOTIFICATIONSFROMTHETECHNICALSUPPORTCENTERTSC(Page1of13)~DuringtheinitialstagesofanemergencytheEChasresponsibilityfornotificationsandPARs.WhentheTSCbecomesoperationaltheTSCECAssistant/Logkeepershouldpreparethenotificationforms.TheTSCOPSCoordinatorishisalternate.TheTSCCommunicatormakescallstocompletenotifications.ATSCCommunicatorshouldforwarddocumentationfromanynotificationsmadefromtheControlRoom,andtheTSC,totheEOF.WhentheEOFbecomesoperationaltheRecoveryManagerhasresponsibilityfornotificationsandPARs.TheTSCCommunicatorisnolongerrequiredtomakenotificationcallsbuttheCommunicator,whoisontheopenlinewiththeNRC,shouldremainonthelinewiththeEOFtakingthelead.~TheTSCECAssistant/Logkeepershouldmakeamentalnoteofthetimewhenthenotificationisdueandensurethatitisdonewithin15minutesofclassification.~Off-siteCommunicationContentandProtocol2.3'.PreparetheFloridaNuclearPlantEmergencyNotificationFormandtheSupplementalDataSheet,pertheinstructionsofthisprocedure.Itshouldbeclearfromthe"ReasonForEmergencyDeclaration"whichEmergencyActionLevel(EAL)requiredtheemergencydeclaration.Wordingshouldbenon-technicalwithnoacronymsorabbreviations(e.g.,reactorcoolantpumpinsteadofRCP).Determining"DownwindSectorsAffected"A.WinddirectioncanbeobtainedfromtheTSCERDADSOperatorordirectlyfromERDADSbydepressingthe"EPIP"keyonthetoprowofthekeyboard.TheMetTowerIndicatorPanelintheUnit1ControlRoomisanalternatesource.B.Iftheindicationisgreaterthan360'hewinddirectionisdeterminedbysubtracting360'romtheindicatednumber.Winddirectionshouldberoundedtothenearestwholenumber.C.Winddirectionisalwaysgivenas"windfrom."(Aneasterlywind,orwinddirection90',meansthatthewindisblowingfromeasttowest).
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUGIE,PLANTPAGE:24of663.APPENDIXBNOTIFICATIONSFROMTHETECHNICALSUPPORTCENTERTSC(Page2of13)(continued)D.E.Whendeterminingthesectorsaffected,theadjacentsectorsonbothsidesoftheactualdownwindsectorareincluded.Threesectorswilltypicallybelisted.Ifthewindislocatedontheedgeofasector(i.e.,11',33',etc.),anadditional(fourth)sectorshouldbeadded.WindFromSectorsAffectedWind'romSectorsAffectedWindFromSectorsAffected348-11HJK123-146PQR11-33JKL146-168QRA33-56'LM168-191RAB56-78LMN191-213ABC78-101MNP213-236BCD101-123NPQThereisno"0"sector4.PARsBasedonPlantConditions236-258CDE258-281DEF281-303EFG303-326FGH326-348GHJThereisno"I"sectorNOTEInitialnotificationfromtheControlRoommayutilizePARsbasedonplantconditions.Oncedoseassessmentbegins,(PARs)shouldbemadeutilizingalloftheavailabledataincludingplantconditions,fieldmonitoringdataoroff-sitedoseprojections.BothplantconditionsANDoff-sitedosesshallbeconsideredforPARs.Themostconservativerecommendationsshouldbemade.IfitisanticipatedthatathresholdforaPARwillbeexceeded,itisneithernecessarynordesirabletowaituntilthethresholdisexceededtomakethatPAR.'.BeginningatthetopleftofthePARflowchartbelow,answertheGeneralEmergencyquestion.B.IftheemergencyisnotaGeneralEmergency(GE),andthereisnorelease,"UtilityRecommendedProtectiveActions"areNONE.C.IfitisaGE,orthereisareleaseinvolved,continueusingtheflowchart.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:25of66,APPENDIXBNOTIFICATIONSFROMTHETECHNICALSUPPORTCENTERTSC(Page3of13)4,(continued)D.UsetheappropriateanswertoeachquestionuntilyoureachoneofthetwoboxesthatprovidePARinformationbasedonplantconditions.E.F.Ifthereisnorelease,gototheTSCPARworksheetandfillitoutbasedonplantconditionsPARs.Ifareleasehasoccurred,getinformationaboutthereleasefromtheTSCChemistrySupervisororTSCHPSupervisor.NOTEIftheClassAModelprintoutisavailableitshouldbeused,then~DeterminePARsbasedonPlantConditions.~Comparethedose-basedPARs,fromtheClassAModelprintout,tothePARsbasedonPlantConditions.~WritethemoreconservativePARsontheTSCPARWorksheet.2.ObtaintheTEDEDose(NOTdoserate)andtheCDEDose(NOTdoserate)forecastsforyouruse.Followthedirectionsbelow,PARsBasedOnOff-SiteDose,andcomparetheresultstofindthemostconservativePARsrecommendations.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:26of66APPENDIXBNOTIFICATIONSFROMTHETECHNICALSUPPORTCENTERTSC(Page4of13)5.PARsBasedOnOff-SiteDoseCAUTIONEvaluateeachdoseseparately.Usetheactualdoseateachmilevalueandmoverighttothecorrespondingdistance.ThePARisattheintersection.DoNOTusethe1MileValue(dose)toattemptfindingPARsfor2-5,5-10or10miledistances.A.FollowthesestepstodeterminePARsBasedonoff-siteDose:1.PARsarebasedontheTotalDose(TEDE)and/ortheThyroidDose(CDE)fromtheDoseCalculationWorksheetinEPIP-09,Off-SiteDoseCalculations.Thissameinformationisavailable,whenusingtheClassAModeldoseprogram,onthe10MileStandardReportintheForecastMode.2.3.5.UsingtheinformationacquiredinStep1,startbyfindingthebox,onthePARsflowchart,thatcorrespondswiththeprojectedTEDEdoseat1mile.Moveacrossrighttothefirstcolumn,whichindicatesthe0-2MilePARforthatdose.WritethatPARinthecorresponding0-2MileblockontheTEDEDOSEtable.CompletetheprocessforbothTEDEandCDE.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:27of66APPENDIXBNOTIFICATIONSFROMTHETECHNICALSUPPORTCENTERTSC(Page5of13)PARsBasedonPlantConditionsCon5nueToAssessCoxMonsYaIActualorProjectedSevereCoreDemagogyNsteItYesILossofPhysicalControlofPlafltyNtts2tYesYMILESNOACllONEVACUATESHELTER02NoneNoneAll24AllRemainingNone(SectorsAffected)5t0AllNoneNoneMILESNOACTIONEVACUATESHELTER0.2NoneAllNone24None(SectorsAffected)AllRemaifing5.10NoneNoneIIJINotest.Seretscoredsmsgelsbtdtcstedtry.LossofsrklcslttnobohAsrsotrrsdIorcoretfotscsoh(sglossofIhjstsohwIlhLocA)oR~Highcoreees~~tes(seriocevgraterthen700')oR~cHARMresdotggreaerIhsnedesRhv.2.tossofohfussdoohbtsofcohstdRoomorvtSIfeederooerstrotresstobthtderLPARsBasedonOff-SiteDose(NottobocornplotodwhonClassAModolIsused)TEDE,DOSETEDE500'99mrem0-2MilosUso1mllevolvoCDE(Thyroid)DOSEOCDE1000%999~ShelterAllmrom2-5MilesUso2milovoluoSholtor(SectorsAffected)sototteI0toooouoosoocottotthohethot0noloOooovotto5-10MilosUso5milovoluoShelter(SectorsAffoctod)OTEDBCDB1%X&49995000-24999~EvacuatoAllmremmromEvacuate(SectorsAffoctod)+SholtorAllRemainingEvscuato(SectorsAffected)+ShelterAllRomslnlngDTEDE5000rrvemor~EvacuateAllorGreaterGreaterTEDEDOSEBvacuato(SectorsAffected)EvacuateAll+ShelterAllRomalningUsethefollowingternainthistable:NONE,ALIALLREMAININGorfillinthelettersofthesectorsaffected.Miles0-22-55-10P10NOACTIONEVACUATESHELTERUsethefotlolvingtermsinthistaMe:NONE,ALL,ALLREMAININGCDE(Thyrcbld)DOSEorpillIntheieffersofthesectorsaffecled.Miles0-22-55-10010NOACTIONEVACUATESHELTERfprrpitprpeeshpprrrartrf REVISIONNO.:PROCEDURENOEPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:28of666.APPENDIXBNOTIFICATIONSFROMTHETECHNICALSUPPORTCENTERTSC(Page6of13)SelectingtheMostConservativePARA.FillouttheTSCPARWORKSHEETbelowbyevaluatingthePARsfromthePARflowchartjustcompleted.B.C.D.WritethemostconservativeinthesectiontitledProtectiveActionsRecommendedbyFPL(usingonlythewordsNONE,ALL,ALLREMAININGorbylistingthelettersofthesectorsaffected).ObtainapprovalandsignatureoftheHPSupervisoror.ChemistrySupervisor.'hecompletedformshouldbeusedtotransferapprovedPARstotheFloridaNuclearPlantEmergencyNotificationForm.
REVISIONNO2PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:29of66APPENDIXBNOTIFICATIONSFROMTHETECHNICALSUPPORTCENTERTSC(Page7of13)TSCPARWORKSHEETTime/DateA.PARComparisonEmergencyClass:0SAEC3GEAftercomparingthepossiblerecommendationsfromthePARsflowchart,themostconservativePARsarebasedon:(checkone)CIPLANTCONDITIONSSectorsaffectedCIOFF-SITEDOSEB.ProtectiveActionsRecommendedbyFPL:Usethefollowingtermsinthistable:NONE,ALL,ALLREMAININGOrfillinthelettersofthesectorsaffected.0-2miles2-5miles5-10miles10-TBDmiles*NOACTIONSECTORSEVACUATESECTORSSHELTERSECTORS*Ifnecessary,addtoStateNotificationForm.SignatureTSCECAssistant/LogkeeperHPSupervisororChemistrySupeivisor REVISIONNO.:PROCEDURENo.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:30of66APPENDIXBNOTIFICATIONSFROMTHETECHNICALSUPPORTCENTERTSC(Page8of13)INITIAL7.Off-siteCommunicationProtocolCAUTION~g~Iferroneousinformationistransmittedtooff-siteagenciesandtheerrorisdiscoveredpriortoeventtermination,acorrectionshouldbeprovidedinanupdate.Theneedforandurgencyofprovidingtheupdateisdependentupontheimportanceoftheerror.~g~Iferroneousinformationistransmittedtooff-siteagencies,andtheerrorisdiscoveredaftereventtermination,theLicensingDepartmentshouldbeconsultedtodeterminetheneedandmethodforcontactingtheoff-siteagencieswithcorrectedinformation.~g3AnewFloridaNuclearPlantEmergencyNotificationFormshallbecornletedforalludates.NOTEgTimeLimitsforNotificationofStateandLocalAgenciesNotificationsshallbemadeassoonaspracticablewithin15minutesofEmerencclassification.A.B.C.ObtaintheEmergencyCoordinator(EC)Approvalsignaturepriortoanyoff-sitecommunication.UsingtheStateHOTRINGDOWN(HRD)Phone,dial100.Holddownthebuttononthehandsetwhiletalking.Thismustbedoneeachtimeyoutalk.Releasethebuttoninordertolisten.WhentheStateanswers,announce"ThisisSt.LucieNuclearPlantTechnicalSupportCenterwithanemergencydeclaration.IamstandingbytotransmitFloridaNuclearPlantEmergencyNotificationForm,informationwhenyouarereadytocopy."AllowtheStateWarningPointtocontactSt.LucieCounty,MartinCountyandtheBureauofRadiationControlpriortotransmittingtheinformationfromtheFloridaNuclearPlantEmergencyNotificationForm.Whenthepartiesareonline,providetheinformationslowlyanddeliberatelywithtimeforthedutyofficerstowritethedata.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:31of66APPENDIXBNOTIFICATIONSFROMTHETECHNICALSUPPORTCENTERTSC(Page9of13)INITIAL7.(continued)D.AlternateCommunicationsifHotRingDownisnotAvailable(IfHRDisused,skiptosectionE,Follow-upInformationRequestsfromStateandLocalAgencies).1.Alternate1-CommercialPhoneNOTEUseofthecommercialtelephoneasanalternatenotificationmethodrequirescallbackverificationfromtheStateWarningPoint.UseofESATCOMorLocalGovernmentRadioasanalternatenotificationmethodshouldincludeacallbackverificationnumberifavailable(e.g.,cellularhone.80CalltheStateWarningPointusingthephonenumberintheSt.LuciePlantEmergencyResponseDirectory(ERD).Announce"ThisisSt.LucieNuclearPlant[asapplicable(Unit1,2,TSCorEOF)]withanemergencydeclaration.MycallbacknumberisHangupthephoneandstandbyforthecallback.WhentheStateWarningPointgivesthego-ahead,providetheinformationfromtheFloridaNuclearPlantEmergencyNotificationForm.c.g2RequestcallbackfromtheStateWarningPointtoverifythattheynotifiedSt.LucieCounty,MartinCountyandtheBureauofRadiationControl~
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:32of66APPENDIXBNOTIFICATIONSFROMTHETECHNICALSUPPORTCENTERTSC(Page10of13)7.D.(continued)2.Alternate2-ESATCOMINITIALNOTEUseESATCOMonlifAlternate1-commercialhoneisnotavailable.a0C.Holddownthe"push-to-talk"buttononthehandsetandwait3-5secondstohearabeepbeforeyoustarttalking.Thismustbedoneeachtimeyoutalk.Announce"StateWarningPoint,thisisSt.LucieNuclearPlant[asapplicable(Unit1,2,TSCorEOF)]withanemergencydeclaration."Thenreleasethe"push-to-talk"buttoninordertolisten.WhentheStateWarningPointacknowledges,announce"StateWarningPoint,thisisSt.LucieNuclearPlant[asapplicable(Unit1,2,TSCorEOF)]declaring~ti).pIamstandingbytotransmitFloridaNuclearPlantEmergencyNotificationForminformationwhenyouarereadytocopy.WhentheStateWarningPointgivesthego-ahead,providetheinformationfromtheFloridaNuclearPlantEmergencyNotificationForm.d.Announce"St.Lucieclear"attheendoftheconversation.
REVISIONNO.:PROCEDURENo.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:33of66APPENDIXBNOTIFICATIONSFROMTHETECHNICALSUPPORTCENTERTSC(Page11of13)7.D.(continued)3.Alternate3-LocalGovernmentRadioINITIALNOTEUselocalgovernmentradioonlyifAlternate1andAlternate2arebothunavailable.LGRcommunicationscanbemadewithSt.LucieCountyandMartinCountyEmergencyOperationsCenters(EOCs)whowillrelaytotheStateWarninPointandtherelatotheBureauofRadiationControl.Bdb.C.d.e.Onchannel2,contactthecountyEOCsbyholdingdownthepush-to-talkbuttonandannouncing"St.LucieCountyEOC,thisisSt..LucieNuclearPlant[asapplicable(Unit1,2,TSCorEOF)]withanemergencydeclaration.Over."Thenreleasethe"push-to-talk"buttoninordertolisten.WhenSt.LucieCountyreplies,directthemtostandbywhileyoucontactMartinCounty.Whenbothcountiesareonline,announce"MartinandSt.LucieCountyEOCs,thisisSt.LucieNuclearPlant[asapplicable(Unit1,2,TddFQF)ldIIg~lifi2ttI~tl).ItdlgdpttransmitFloridaNuclearPlantEmergencyNotificationForminformationwhenyouarereadytocopy.Over."Whenthecountiesgivethego-ahead,providetheinformationfromtheFloridaNuclearPlantEmergencyNotificationForm.RequestSt.LucieCounty(iftheyareunable,MartinCounty)callbacktoverifythattheynotifiedtheStateWarningPointandtheBureauofRadiationControl~Endtheconversationbyannouncing"ThisisSt.LucieNuclearPlant[asapplicable(Unit1,2,TSCorEOF)],KNGR874,overandout."
REVISIONNo.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONS.ST.LUCIEPLANTPAGE:34of667.APPENDIXB'OTIFICATIONSFROMTHETECHNICALSUPPORTCENTERTSC(Page12of13)(continued)E.EmergencyFollow-upInformationRequestsfromStateandLocalAgenciesIncomingcallsshouldcomeviatheStateWarningPoint(SWP)overtheHOTRINGDOWN(HRD)phone.IftheHRDisinoperable,theSWPmayusecommercialtelephoneorESATCOM.Ifanoff-siteauthoritycontactsthePlantwithoutgoingthroughtheSWP,requestthattheycontacttheSWP.SWPshallverifythattheagencycallingisariskcountyortheDepartmentofHealth(DOH)andshallnotifyothercountyandstateagenciesoftheupdatedinformation,thusreducingthenumberofcallsthatmaybedirectedtothePlant.2.Long,detailedexplanationsofplantsystemsorreactortheoryshouldbeavoided.IfpromptedforthiskindofinformationbytheStateDutyOfficer,referhimtotheNuclearDivisionDutyOfficer(NDDO).
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:35of66APPENDIXBNOTIFICATIONSFROMTHETECHNICALSUPPORTCENTERTSC(Page13of13)7.(continued)F.gNRCNotificationINITIALNOTENotificationoftheNRCisexpectedimmediatelyafternotificationofStateandlocalagencies.Theone-hourtimelimitiri10CFR50.72(a)(3)istoensuretimelyNRCnotificationincaseswherenotificationofStateandlocalaenciesisdelaedorroloned.3.TheinitialcontactwiththeNRCwillincludeuseoftheNRCReactorPlantEventNotificationWorksheet(Attachment3).TheDutyCallSupervisor(DCS),orotherpersonnelintheControlRoom,mayhaveperformedthisfunction.TheCommunicatorwillneedtoensurethataninitialNRCReactorPlantEventNotificationWorksheethasbeencompleted.Ifnotyetdone,requestthattheTSCECAssistant/Logkeeper,orTSCOPSCoordinator,completeonepriortoestablishingtheopenlinewiththeNRC.OncetheopenlineisestablishedtheCommunicatorwilllogquestionsbutnotgeneratemoreNRCReactorPlantEventNotificationWorksheets.ObtainECapprovalofworksheet,asapplicable.NotifytheNRCviatheEmergencyNotificationSystem(ENS)telephoneimmediatelyafternotificationoftheappropriateStateorlocalagenciesandnotlaterthanonehourafterthetimethelicenseedeclaresoneoftheEmergencyClasses(10CFR50.72(a)(3)).TheNRCEmergencyNotificationSystem(ENS)istheprimarycommunicationspathwaytotheNRC.Initiatecontactbydialing(direct,noaccesscodeneeded)oneofthephonenumbersprovidedonthephoneorintheERD.ThiswillbecomeanopenlineofcommunicationattheAlertorhigheremergencyclass.ENDOFAPPENDIXB REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:36of66APPENDIXCNOTIFICATIONSFROMTHEEMERGENCYOPERATIONSFACILITYEOF(Page1of13)WhentheEOFbecomesoperationaltheRecoveryManagerhasresponsibilityfornotificationsandPARs.AnEOFRMOPSAdvisorshouldpreparethenotificationformsandtheEOFCommunicatormakescallstocompletenotifications.AnEOFCommunicatorshouldreceivedocumentationfromtheTSCofanynotificationsthatweremadefromtheControlRoomandTSC.ThesedocumentscanbereceivedbyFAX.AnEOFCommunicatorwilltaketheleadontheopenlinewiththeNRC.TheTSCCommunicatorshouldremainonthelinetoprovideinformationfromsourcesavailableintheTSC.~TheEOFRMOPSAdvisorshouldmakeamentalnoteofthetimewhenthenotificationisdueandensurethatitisdonewithin15minutesofclassification.~Off-siteCommunicationContentandProtocol1.PreparetheFloridaNuclearPlantEmergencyNotificationFormandtheSupplementalDataSheet,pertheinstructionsofthisprocedure.2.'tt4AftertheStateCoordinatingOfficerarrivesintheEOF,thisindividualcantransfer"NETControl"totheEOF.WhenthisoccurstheRecoveryManager'sbriefingsbecometheprimarynotificationmethodfortheStateandCounties.TheFloridaNuclearPlantEmergencyNotificationForm(includingSupplementalDataSheet)shouldstillbecompletedandprovidedtotheStateCoordinatingOfficerorhis/herdesigneeintheEOF.CallsbyFPLpersonnelovertheHotRingDowntelephonewouldnolongerbemade.3.Itshouldbeclearfromthe"ReasonForEmergencyDeclaration"whichEmergencyActionLevel(EAL)requiredtheemergencydeclaration.Wordingshouldbenon-technicalwithnoacronymsorabbreviations(e.g.,reactorcoolantpumpinsteadofRCP).4.Determining"DownwindSectorsAffected"A.WinddirectioncanbeobtainedfromtheEOFERDADSOperatorordirectlyfromERDADSbydepressingthe"EPIP"keyonthetoprowofthekeyboard.IfERDADSisunavailable,theinformationcanbeobtainedfromtheTSC.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:37of66APPENDIXCNOTIFICATIONSFROMTHEEMERGENCYOPERATIONSFACILITYEOF(Page2of13)4.(continued)B.Iftheindicationisgreaterthan360'hewinddirectionisdeterminedbysubtracting360'romtheindicatednumber.Winddirectionshouldberoundedtothenearestwholenumber.C.D.E.Winddirectionisalwaysgivenas"windfrom."(Aneasterlywind,orwinddirection90',meansthatthewindisblowingfromeasttowest).Whendeterminingthesectorsaffected,theadjacentsectorsonbothsidesoftheactualdownwindsectorareincluded.Threesectorswilltypicallybelisted.Ifthewindislocatedontheedgeofasector(i.e.,11',33',etc.),anadditional(fourth)sectorshouldbeadded.WindFromSectorsAffectedWindFromSectorsAffectedWindFromSectorsAffected348-11HJK123-146PQR11-33JKL146-168QRA33-56KLM168-191RAB56-78LMN191-213ABC78-101MNP213-236BCD101-123NPQThereisno"0"sector5.PARsBasedonPlantConditions236-258CDE258-281DEF281-303EFG303-326FGH326-348GHJThereisno"I"sectorNOTEInitialnotificationfromtheControlRoommayutilizePARsbasedonplantconditions.Oncedoseassessmentbegins,(PARs)shouldbemadeutilizingalloftheavailabledataincludingplantconditions,fieldmonitoringdataoroff-sitedoseprojections.BothplantconditionsANDoff-sitedosesshallbeconsideredforPARs.Themostconservativerecommendationsshouldbemade.IfitisanticipatedthatathresholdforaPARwillbeexceeded,itisneithernecessarynordesirabletowaituntilthethresholdisexceededtomakethatPAR.A.BeginningatthetopleftofthePARflowchartbelow,answertheGeneralEmergencyquestion.
REVISIONNO.:PROCEDURENoEPIP-08PROCEDURE'TITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:38of66APPENDIXCNOTIFICATIONSFROMTHEEMERGENCYOPERATIONSFACILITYEOF(Page3of13)5.(continued)B.IftheemergencyisnotaGeneralEmergency(GE),andthereisnorelease,"UtilityRecommendedProtectiveActions"areNONE.C.IfitisaGE,orthereisareleaseinvolved,continueusingtheflowchart.D.UsetheappropriateanswertoeachquestionuntilyoureachoneofthetwoboxesthatprovidePARinformationbasedonplantconditions.E.Ifthereisnorelease,gototheEOFPARWorksheetandfillitoutbasedonplantconditionsPARs.F..Ifareleasehasoccurred,gettheinformationaboutthereleasefromtheEOFHPManagerorDoseAssessor.NOTEIftheClassAModelprintoutisavailableitshouldbeused,then~DeterminePARsbasedonPlantConditions.~Comparethedose-basedPARs,fromtheClassAModelprintout,tothePARsbasedonPlantConditions.WritethemoreconservativePARsontheEOFPARWorksheet.1.ObtaintheTEDEDose(NOTdoserate)andtheCDEDose(NOTdoserate)forecastsforyouruse.2.Followthedirectionsbelow,PARsBasedOnOff-SiteDose,andcomparetheresultstofindthemostconservativePARsrecommendations.
REVISIONNO.:PROCEDURENo.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:39of66APPENDIXCNOTIFICATIONSFROMTHEEMERGENCYOPERATIONSFACILITYEOF(Page4of13)6.PARsBasedOnOff-SiteDoseCAUTIONEvaluateeachdoseseparately.Usetheactualdoseateachmilevalueandmoverighttothecorrespondingdistance.ThePARisattheintersection.DoNOTusethe1MileValue(dose)toattemptfindingPARsfor2-5,5-10or10miledistances.A.FollowthesestepstodeterminePARsBasedonoff-siteDose:PARsarebasedontheTotalDose(TEDE)and/ortheThyroidDose(CDE)fromtheDoseCalculationWorksheetinEPIP-09,Off-SiteDoseCalculations.Thissameinformationisavailable,whenusingtheClassAModeldoseprogram,onthe10MileStandardReportintheForecastMode.Usingthe.informationacquiredinStep1,startbyfindingthebox,onthePARsflowchart,thatcorrespondswiththeprojectedTEDEdoseat1mile.3.4.5.Moveacrossrighttothefirstcolumn,whichindicatesthe0-2MilePARforthatdose.WritethatPARinthecorresponding0-2MileblockontheTEDEDOSEtable.CompletetheprocessforbothTEDEandCDE.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:40of66APPENDIXCNOTIFICATIONSFROMTHEEMERGENCYOPERATIONSFACILITYEOF(Page5of13)PARsBasedonPlantConditionsGeneralEmergency?ContinueToAssessConditionsActualorProjSevereCoreOamageglfdeILossofPhysicalControlofPlentyIION2MILESNOACTIONEVACUATESHELTER0.2NoneNoneAll2-5AllRemainingNone(SectorsAffected)5.10AllNoneNonevaMILESNOACTIONEVACUATESHELTER0.2NoneAlNone2-5None(SectorsAffected)AIIRemaining5-10NoneNoneAll1.SeverecoredamageIshdoctadten~tossotcrtkslfvnctensrecsrredlorcorepcc<<don(e.g.lossofsfpcdonorthtoes)oR~Htghcoretemperatures(veldcargreaterthan7pfpr)oR~CHRRMreadnggreaterthan4254IMv.2.LeesofphrasalconbldofcontrolRoomorvealreaderopers5llg<<easlosevdarLPARsBasedonOff-SiteDose(NottobocomplotodwhonClassAModollsusod)TEDEDOSETEDC500999mremCDE(Thyroid)02MilesDOSEUso1mllevalueDCDE1OOOF999~ShenerAllmrem2-5MllosUso2milovalueShelter(SectorsAffocted)serenat0recceueeOeecoaeeneeau>>10reaeDoseveaee510MllosUso5mllevalueSheher(sectorsAffected)OoeebeloweeelevelreavoeeNOAOTIOMOTEDC1000&999mremDCDE5000-24999~EvacuateANmremEvacuate(SectorsAffected)ShelterANRemainingEvacuate(SectorsAffecled)ShelterANRemainingOTEDCCDE5000mremorŽ~EvacuateANGreaterGreaterTEDEDOSEEvacuate(SectorsAffected)EvacuateAN+ShelterANRemainingUsethefolbwingtermsinthistaMe:NONE,ALL,ALLREMAININGorfillinthelettersofthesectorsaffected.Mlles0-22-55-10P10NOACTIONEVACUATESHELTERUsethefollowingtermsinthistable:NONE,ALIALLREMAININGCDE(Thyroid)DOSEorfigInthefeitersofthesectorsaffected.Mlles0-frp2-55-10,010NOACTIONEVACUATESHELTERp&p4plpoarnppcrtr)
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:41of66APPENDIXCNOTIFICATIONSFROMTHEEMERGENCYOPERATIONSFACILITYEOF7.(Page6of13)SelectingtheMostConservativePARA.FillouttheEOFPARWORKSHEETbelowbyevaluatingthePARsfromthePARflowchartjustcompleted.B.C.D.WritethemostconservativeinthesectiontitledProtectiveActionsRecommendedbyFPL(usingonlythewordsNONE,ALL,ALLREMAININGorbylistingthelettersofthesectorsaffected)~ObtainapprovalandsignatureoftheHPManager.ThecompletedformshouldbeusedtotransferapprovedPARstotheFloridaNuclearPlantEmergencyNotificationForm.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLEOFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:42of66APPENDIXCNOTIFICATIONSFROMTHEEMERGENCYOPERATIONSFACILITYEOF(Page7of13)EOFPARWORKSHEETTime/DateA.PARComparisonEmergencyClass:CISAE0GEAftercomparingthepossiblerecommendationsfromthePARsflowchart,themostconservativePARsarebasedon:(checkone)0PLANTCONDITIONSSectorsaffected0OFF-SITEDOSEB.ProtectiveActionsRecommendedbyFPL:Usethefollowingtermsinthistable:NONE,ALL,ALLREMAININGOrfillinthelettersofthesectorsaffected.0-2miles2-5miles5-10miles10-TBDmiles*NOACTIONSECTORSEVACUATESECTORSSHELTERSECTORS*Ifnecessary,addtoStateNotificationForm.SignatureRMOPSAdvisor/LogkeeperHPManagerC.ProtectiveActionsImplementedbytheState/Counties:AreasTimeSirensSounded:
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:43of66APPENDIXCNOTIFICATIONSFROMTHEEMERGENCYOPERATIONSFACILITYEOF(Page8of13)INITIAL8.Off-siteCommunicationProtocolCAUTION~g~Iferroneousinformationistransmittedtooff-siteagenciesandtheerrorisdiscoveredpriortoeventtermination,acorrectionshouldbeprovidedinanupdate.Theneedforandurgencyofprovidingtheupdateisdependentupontheimportanceoftheerror.~g~Iferroneousinformationistransmittedtooff-siteagencies,andtheerrorisdiscoveredaftereventtermination,theLicensingDepartmentshouldbeconsultedtodeterminetheneedandmethodforcontactingtheoff-siteagencieswithcorrectedinformation.~tbAnewFloridaNuclearPlantEmergencyNotificationFormshallbecornletedforalludates.NOTEIITimeLimitsforNotificationofStateandLocalAgenciesNotificationsshallbemadeassoonaspracticablewithin15minutesofEmerencclassification.A.B.ObtaintheRecoveryManager(RM)Approvalsignaturepriortoanyoff-sitecommunication.'tt4IftheStateCoordinatingOfficerhastransferredNETControltotheEOF,theRMshalldothecommunicationface-to-face.TheFloridaNuclearPlantEmergencyNotificationForm(formsimilartoAttachment2)andtheSupplementalDataSheet(formsimilartoAttachment2A)shouldstillbecompletedandprovidedtotheStateCoordinatingOfficerorhisIher.designeeintheEOF.CallsbyFPLpersonneloverHotRingtelephoneshouldnolongerbemade.C.IfNETControlhasnotbeentransferredtotheEOF;then,usingtheStateHOTRINGDOWN(HRD)phone,dial100.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:44of66APPENDIXCNOTIFICATIONSFROMTHEEMERGENCYOPERATIONSFACILITYEOF(Page9of13)INITIAL8.(continued)D.E.Holddownthebuttononthehandsetwhiletalking.Thismustbedoneeachtimeyoutalk.Releasethebuttoninordertolisten.WhentheStateanswers,announce"ThisisSt.LucieNuclearPlantEmergencyOperationsFacilitywithanemergencydeclaration.IamstandingbytotransmitFloridaNuclearPlantEmergencyNotificationForminformationwhenyouarereadytocopy."AllowtheStateWarningPointtocontactSt.LucieCounty,MartinCountyandtheBureauofRadiationControlpriortotransmittingtheinformationfromtheFloridaNuclearPlantEmergencyNotificationForm.Whenthepartiesareonline,providetheinformationslowlyanddeliberatelywithtimeforthedutyofficerstowritethedata.AlternateCommunicationsifHotRingDownisnotAvailable(IfHRDisusedorNETControlhasbeentransferredtotheEOF,skiptosectionF,NRCNotification).1..Alternate1-CommercialPhoneNOTEUseofthecommercialtelephoneasanalternatenotificationmethodrequirescallbackverificationfromtheStateWarningPoint.UseofESATCOMorLocalGovernmentRadioasanalternatenotificationmethodshouldincludeacallbackverificationnumberifavailable(e.g.,cellularhone.80CalltheStateWarningPointusingthephonenumberintheSt.LuciePlantEmergencyResponseDirectory(ERD).Announce"ThisisSt.LucieNuclearPlant[asapplicable(Unit1,2,TSCorEOF)]withanemergencydeclaration.Mycallbacknumberis REVISIONNo.:PROCEDURENo.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:45of66APPENDIXCNOTIFICATIONSFROMTHEEMERGENCYOPERATIONSFACILITYEOF(Page10of13)INITIAL8.E.(continued)b.C.Hangupthephoneandstandbyforthecallback.WhentheStateWarningPointgivesthego-ahead,provide.theinformationfromtheFloridaNuclearPlantEmergencyNotificationForm.RequestcallbackfromtheStateWarningPointtoverifythattheynotifiedSt.LucieCounty,MartinCountyandtheBureauofRadiationControl.2.Alternate2-ESATCOMMOTEUseESATCOMonlifAlternate1-commercialhoneisnotavailable.C.Holddownthe"push-to-talk"buttononthehandsetandwait3-5secondstohearabeepbeforeyoustarttalking.Thismustbedoneeachtimeyoutalk.Announce"StateWarningPoint,thisisSt.LucieNuclearPlant[asapplicable(Unit1,2,TSCorEOF)]withanemergencydeclaration."Thenreleasethe"push-to-talk"buttoninordertolisten.WhentheStateWarningPointacknowledges,announce"StateWarningPoint,thisisSt.LucieNuclearPlant[asapplicable(Unit1,2,TSCorEOF)]declaringan(classification),pt(If)Itdgtl'ttransmitFloridaNuclearPlantEmergencyNotificationForminformationwhenyouarereadytocopy."WhentheStateWarningPointgivesthego-ahead,providetheinformationfromtheFloridaNuclearPlantEmergencyNotificationForm.Announce"St.Lucieclear"attheendoftheconversation.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:46of66APPENDIXCNOTIFICATIONSFROMTHEEMERGENCYOPERATIONSFACILITYEOF(Page11of13)INITIAL8.E.(continued)3.Alternate3-LocalGovernmentRadioNOTEUselocalgovernmentradioonlyifAlternate1andAlternate2arebothunavailable.LGRcommunicationscanbemadewithSt.LucieCountyandMartinCountyEmergencyOperationsCenters(EOCs)whowillrelaytotheStateWarninPointandtherelatotheBureauofRadiationControl.adb.C.d.e.Onchannel2,contactthecountyEOCsbyholdingdownthepush-to-talkbuttonandannouncing"St.LucieCountyEOC,thisisSt.LucieNuclearPlant[asapplicable(Unit1,2,TSCorEOF)]withanemergencydeclaration.Over."Thenreleasethe"push-to-talk"buttoninordertolisten.WhenSt.LucieCountyreplies,directthemtostandbywhileyoucontactMartinCounty.Whenbothcountiesareonline,announce"MartinandSt.LucieCountyEOCs,thisisSt.LucieNuclearPlant[asapplicable(Unit1,g.fggEgpttdIIgtIIftptali~tt.Igdt~PfttransmitFloridaNuclearPlantEmergencyNotificationForminformationwhenyouarereadytocopy.Over."Whenthecountiesgivethego-ahead,providetheinformationfromtheFloridaNuclearPlantEmergencyNotificationForm.RequestSt.LucieCounty(iftheyareunable,MartinCounty)callbacktoverifythattheynotifiedtheStateWarningPointandtheBureauofRadiationControl.Endtheconversationbyannouncing"ThisisSt.LucieNuclearPlant[asapplicable(Unit1,2,TSCorEOF)],KNGR874,overandout."
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:47of66APPENDIXCNOTIFICATIONSFROMTHEEMERGENCYOPERATIONSFACILITYEOF(Page12of13)INITIAL8.(continued)F.'NRCNotificationNOTENotificationoftheNRCisexpectedimmediatelyafternotificationofStateandlocalagencies.Theone-hourtimelimitin10CFR50.72(a)(3)istoensuretimelyNRCnotificationincaseswherenotificationofStateandlocalaenciesisdelaedorroloned.2.TheinitialcontactwiththeNRCwillincludeuseoftheNRCReactorPlantEventNotificationWorksheet(Attachment3).ControlRoomorTSCpersonnelmayhaveperformedthisfunction.TheCommunicatorwillneedtoensurethataninitialNRCReactorPlantEventNotificationWorksheethasbeencompleted.TheEOFCommunicatorshouldrequestdocumentationofanynotification(s),stateorNRC,madepriortothispointiftheyhavenotyetbeenreceived.IfNRCnotificationhasnotbeenmade,theEOFRMOPSAdvisorshallcompleteaWorksheet,priortoestablishingtheopenlinewiththeNRC.OncetheopenlineisestablishedtheCommunicatorwilllogquestionsbutnotgeneratemoreWorksheets.ObtainRMapprovalofworksheet,asapplicable.C REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:48of66APPENDIXCNOTIFICATIONSFROMTHEEMERGENCYOPERATIONSFACILITYEOF(Page13of13)INITIAL8.F.(continued)3.NotifytheNRCviatheEmergencyNotificationSystem(ENS)telephoneimmediatelyafternotificationoftheappropriateStateorlocalagenciesandnotlaterthanonehourafterthetimethelicenseedeclaresoneoftheEmergencyClasses(10CFR50.72(a)(3)).TheNRCEmergencyNotificationSystem(ENS)istheprimarycommunicationspathwaytotheNRC.Initiatecontactbydialing(direct,noaccesscodeneeded)oneofthephonenumbersprovidedonthephoneorintheERD.Thisbecomesanopenlineofcommunicationat-theAlertorhigheremergencyclass.TheTSCislikelytohavealreadyestablishedthisopenline.TheEOFCommunicatorshouldcalltheNRCandrequesttobeputontheconferencebridgewiththeNRCandSt.LucieTechnicalSupportCenter.TheEOFshouldtaketheleadandlogquestionsfromtheNRC.ENDOFAPPENDIXC REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:49of66ATTACHMENT1PRIMARYEMERGENCYCOMMUNICATIONSSYSTEMS(Page1of3)COMMUNICATIONSSYSTEMSA.StateWarningPoint(SWP)HotRingDownPhone(HRD)1.ThisistheprimarycommunicationspathwaytotheStateWarningPoint,St.LucieCounty,MartinCountyandtheBureauofRadiationControl.2.Aself-verifyingphonesystemwhichisinitiatedbyenteringthe3digitcodecorrespondingtothedesiredlocationofcontact.Thecodesappearonalistinapull-outdrawerattachedtothebaseofthephoneorintheSt.LuciePlantEmergencyResponseDirectory(ERD).Aconfirmationring-back(doubletone)willbeheardifthedialedterminalissuccessfullycontacted.Whenthepartyanswers,begintransmissionbydepressingthe"push-to-talk"barinthehandset.Releasethe"push-to-talk"bartoreceiveresponse.B.NRCEmergencyNotificationSystem(ENS)'1.ThisistheprimarycommunicationspathwaytotheNRC.2.Initiatecontactbydialing(direct,noaccesscodeneeded)oneofthephonenumbersprovidedonthephoneorintheERD.ThiswillbecomeanopenlineofcommunicationattheAlertorhigheremergencyclass.TheEOFwilljointheconferencebridgeifitbecomesoperational.C.Direct-lineTelephone1~ThisisadirectlinebetweentheTSCandtheEOF.Initiatecontactbyremovingthehandsetfromthecradle,whichwillcausethephonetoringintheotherfacility.Whenthephoneisansweredyoucanbegintransmission.
REVISIONNO.:.PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:50of66ATTACHMENT1PRIMARYEMERGENCYCOMMUNICATIONSSYSTEMS(Page2of3)(continued)D.Sound-poweredPhone1.ThisisalinkbetweentheControlRoomandtheTSC.Thesephone(headsets)arepoweredbysound.2.IntheTSCtheUnit1phonejackislocatedneartheDoseAssessmentStatusBoard;theUnit2phonejackislocatednexttotheChronologyStatusBoardintherearoftheroom.3.OncetheheadsetshavebeenconnectedinboththeaffectedControlRoomandtheTSC,transmissioncanbeginbyspeakingintothemouthpiece.E.CommercialTelephone1.ThisisthefirstalternatecommunicationspathwaytotheStateWarningPoint,St.LucieCounty,MartinCounty,theBureauofRadiationControlandtheNRC.F.2.Dial9foraFortPierceexchange;dial8-1-AreaCodeforallothernumbers.Anauthorizationcodeisneededforlongdistancecalls.EmergencySatelliteCommunicationsSystem(ESATCOM)1~ThisisasecondalternatecommunicationspathwaytotheStateWarningPoint,St.LucieCounty,MartinCountyandtheBureauofRadiationControl.2.Toinitiatetransmission,liftthehandsetanddepressthe"push-to-talk"barinthehandset.Wait3-5secondstohearabeepbeforestartingtotalk.Theredlightonthephoneisapowerindicator,whenlit,powerisavailable.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:51of66ATTACHMENT1PRIMARYEMERGENCYCOMMUNICATIONSSYSTEMS(Page3of3)(continued)G.H.LocalGovernmentRadio(LGR)-CallSign:KiloNovemberGolfRomeo8-7-4(KNGR874).ThisisthethirdalternatecommunicationspathwaytotheStateWarningPoint,St.LucieCounty,MartinCountyandtheBureauofRadiationControl~TheLGRservesasabackupcommunicationssystemtothecountiesandindirectlytoStateagencies.Atableradio,MotorolaCommandSeries,providestwochannels,theprimaryF2(39.180MHz,StateChannel1)andthesecondaryF1(39.100MHz,StateChannel2).Channelselectioncanbemadebydepressingthe"F1/F2"button(theradioissettomonitorF2).Theradiocanbeoperatedeitherbydepressingthe"transmit"buttonontheconsoleorbyremovingthehandsetanddepressingthe"push-to-talk"barinthehandset.The"xmit"lightislitduringtransmission.(Preferenceshouldbegiventousingthehandset).SatelliteTelephone1~Instructionsforuseofthesatellitetelephoneareprovidedinthephone'sbriefcase.2.ThephoneisstoredinasupplycabinetintheTSC.ENDOFATTACHMENT1 REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:52of66ATTACHMENT2FLORIDANUCLEARPLANTEMERGENCYNOTIFICATIONFORM(Page1of1)1.A.0THISISADRILLB.0THISISANACTUALEVENT2.A.Time/DatecontactmadeC.MessageNumber3.Site:A.0CrystalRiverUnit3D.0TurkeyPointUnit3B.Reportedby:(Name/Title)D.Reportedfrom:0ControlRoom0TSC0EOFB.0St.LuciaUnit1C.0St.LucieUnit2E.0TurkeyPointUnit44.AccidentClassificationA.0NotificationofUnusualEventC.0SiteAreaEmergencyB.0AlertD.0GeneralEmergency5.CurrentEmeenDeclaration:Time:Date:6.ReasonforEmerencDeclaration7.AdditionalInformationorUdate:A.WinddirectionfromdegreesB.DownwindSectorsAffected(minimumof3):10.ReleaseStatus:A.0NoRelease(GotoItem12)C.0AReleaseoccurred,butstoppedB.0AReleaseisoccurring11.OffsiteReleaseSinificanceCateoaheSieBoundaA.0Informationnotavailableatthistime.B.0Releasewithinnormaloperatinglimits(63.5E-1ci/secnoblegas,~4.6E-5ci/seciodine)C.0Non-SignificantFractionofPAGRange(releaseis)normallimitsand(500mRTEDEand1000mRCDE)D.0PAGRange(h500mRTEDEor21000mRCDE)9.WeatherData8.In'uriesReuirinOffsiteSuort:A.0No0Yes0UnknownB.Contaminated:0No0Yes0Unknown12.UtiliRecommendedProtectiveActions:A.0NoneB.0ShelterZones/Areas:EvacuateZones/Areas:ORC.0MilesNoActionSectorsEvacuateSectors0-22-55-10ShelterSectors13.HasEventBeenTerminated?:A.QNo14.SufementalFormisAttached':A.0NoB.0Yes:B.0Yes:Time:Date:ECorRMApprovalSignature:Time:Date:15.MessaeReceivedB:Name:Time:Date:'fomorgoncyclassescalationisknowntobonecessaryandanewnotificationformwillbetransmittedwithin15minutes,thonyoumaygotoline15.PSL-F070ENDOFATTACHMENT2EffectiveDate:05/31/00
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:53of66ATTACHMENT2ASUPPLEMENTALDATASHEET(Page1of1)ThefollowingsupplementaldataistobecompletedaftertheTSCorEOFisdeclaredoperationalatAlertorhigher.SupplementtoMessageNumberPLANTCONDITIONSINFORMATIONCriticalSafeFunctions:A.ReactorShutdown'0YesB.CoreAdequatelyCooled?0YesC.AdequateEmergencyPowerAvailable(Diesels)'?0YesFissionProductBarrierStatus:(Checkoneconditionforeachbarrier)0No0No0NoBARRIERFuelCladdingPri.ReactorCoolantSystemContainmentINTACTNoindicationofcladdamageLeakageiswithinnormalchargingormakeuppumpcaacitNoevidenceofcontainmentleakageortuberupturereleaseisonlythrouhcondenserCHALLENGEDCladisintactbutlosingsubcooling,waterlevel,etc.LeakageiswithinsafetyinjectioncapacityNoleakagebutcontainmentpressureIsatorabovesafetysystemactuationpointsLOSTCladhasfailed,Indicatedbyhightemps.,highcontainmentrad,etc.LeakageexceedssafetyInjectioncapacityEvidenceofcontainmentleakage(knownreleasepathorradsurveys)REGAINEDCoolingrestored,nofurtherdegradationexectedLeakagereducedtowithininjectioncapacity(systemrepaired)RepaireffortshaveisolatedleakorcontainmentpressurehasreducedtostopleakaeCompletedby:Time:Date:2.ReleaseRate:A.0NobleGases:CuriespersecondB.0lodines:CuriespersecondA.0AirborneTime/DateStarted:Time/DateStopped:4.Pro'ectedOff-SiteDoseRate:DistanceThroidDoseRateCDE1Mile(SiteBoundary)A.mrem/hr2MilesC.mrem/hr5MilesE.mrem/hr10Miles'.mrem/hr5.WeatherDatausedfortheabovedata:A.WindDirectionfromdegreesB.WindSpeedMPHC.StabilityClassCompletedBy:EmergencyCoordinatororRecoveryManagerApproval0Measured0Default0Measured0DefaultB.0LiquidTime/DateStarted:Time/DateStopped:TotalDoseRateTEDEmrem/hrmrem/hrmrem/hrmrem/hrB.D.F.H.Date:Time:RADIOLOGICALDOSEASSESSMENTDATA1.ReleaseStatus:A.0NoRelease(nofurtherdatarequired)C.0AReleaseoccurred,butstoppedB.0AReleaseisoccurringPSL-F071ENDOFATTACHMENT2AEffective:05/31/00 REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:54of66ttsATTACHMENT2BDIRECTIONSFORCOMPLETINGTHEFLORIDANUCLEARPLANTEMERGENCYNOTIFICATIONFORM(Page1of6)ITEMENTRY2A2B.2C.Checkappropriateboxfordrilloractualemergencyasthecasemaybe.Duringexercises,drills,ortests,eachmessageshallbecheckedTHISISADRILL.Enterthetime(usingtheofficialtime,normallysynchronizedwithERDADS)whencontactismadewiththeStateWarningPointortheStateCoordinatorOfficer(SCO).Forinitialnotificationofclassification,thisshallbewithin15minutesofthe"CurrentEmergencyDeclaration"timeinitem5.Enterthenameandtitleofpersonmakingthenotificationcall(e.g.,JohnDoe,DutyCallSupervisor).Enterthemessagenumberbeginningwith¹1andfollowingsequentiallyinallfacilities(e.g.,iftheControlRoomtransmittedtwomessagestheTSCwouldstartwith¹3).2D.Checktheboxforthefacilityfromwhichthenotificationisbeingmade.SiteChecktheboxfortheappropriateplantsitefortheemergencydeclaration(bothStLucieboxesmightneedtobecheckedfordualuniteventssuchasapproachofahurricane).AccidentClassificationChecktheboxcorrespondingtocurrentaccidentclassificationdeclaredbytheEC.CurrentEmerencDeclarationEntertheemergencydeclarationtimeanddate(asdeterminedbytheEC)forthecurrentaccidentclassification.ReasonforEmerencDeclarationEnterwordinglikethatfoundintheEmergencyActionLevel(EAL)informationinEPIP-01,ClassificationOfEmergencies.Wordingshouldbebriefyetdescriptiveenoughfortheoff-siteagenciestogainanunderstandingoftheevent.ItshouldbeclearfromtheincidentdescriptionwhichEALhasnecessitatedtheemergencydeclaration.Wordingshouldbeasnon-technicalaspossiblewithnoacronymsorabbreviations.Thisinformationshouldremainthesamethroughoutupdatemessages,unlessthereisaclassificationchange.(TheEChasthisinformation.)
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:55of66ATTACHMENT2BDIRECTIONSFORCOMPLETINGTHEFLORIDANUCLEARPLANTEMERGENCYNOTIFICATIONFORM(Page2of6)7.AdditionalInformationorUdateEnteradditionalinformation,ifnecessary,orreasonforupdatehere.Forexample:~ProtectiveActionRecommendations(PARs)change~Anoccurrencethatwouldotherwiseresultinaloweremergencyclassification,onotherunit~Weatherchangesaffectingpublicsafety~Radiationlevelchanges~Lossofoff-sitepower,etc.8.In'uriesReuirinOff-siteSuortNOTEKeepcheckingthesameboxes,initem8,onsubsequentnotificationsunlessafirstinjuryoccurs,statusofcontaminationbecomesknownorerroneousdataisbeingcorrected.ThecheckedboxistoalerttheCountythatpati'enttransportisinvolvedintheemergency.Thatfactdoesnotchangeeventhoughthetransportmayhavealreadyoccurredduringareviousnotification.Checktheappropriatebox.Checkboxfor"Yes"onlyifinjuriesoccurredthatinvolveoff-sitesupport(EMS,hospital).Check"Unknown"iftheextentoftheinjuriesareunknownatthistimeorifitisnotyetknownifoff-sitetreatmentisnecessary.B.Checktheappropriatebox.Checkboxfor"Unknown"onlyifthenatureoftheinjurieshavepreventedthoroughmonitoringon-siteorifthereisanydoubtwhethercontaminationispresent.NOTEIftheClassAModelisbeingused,a'StateNotificationFormSummarySheet'savailablewhichprovidesinformationforcompletionofitems9-12.TheinformationisinaformatsimilartothatfoundontheFloridaNuclearPlantEmerencNotificationForm.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:56of66ATTACHMENT2BDIRECTIONSFORCOMPLETINGTHEFLORIDANUCLEARPLANTEMERGENCYNOTIFICATIONFORM(Page3of6)9.WeatherDataA.Enterthewinddirection(windfrom)indegreesinitem"A."NOTEThewinddirectioncanbeobtainedfromERDADSbydepressingthe"EPIP"key,onthetoprowofthekeyboard,orbycheckingtheMetTowerIndicatorPanelonUnit1.Iftheindicationisgreaterthan360'hewinddirectionwouldbedeterminedbysubtracting360'romtheindicatednumber.Winddirectioncanberoundedtothenearestwholenumber.B.EntertheDownwindSectorsinitem"B."WindFromSectorsWindSectorsAffectedFromAffectedWindFromSectorsAffected348-11HJK123-146PQR236-258CDE11-33JKL146-168QRA33-56KLM168-191RAB56-78LMN191-213ABC78-101MNP213-236~BCD101-123NPQThereisno"0"sector10.ReleaseStatus258-281DEF281-303EFG303-326FGH326-348GHJThereisno"I"sectorA.Iftherearenoindicationsofaradioactiverelease,checkbox"A"andgotoitem12.Arelease(duringanydeclaredemergency)isdefinedas:Anyeffluentmonitorincreaseof(approximately)10timesoronedecadeabovepre-transientvaluesOR~HealthPhysicsdetectingairborneradioactivitylevelsinexcessof25%derivedairconcentration(DAC)outsideofplantbuildingsduetofailureofequipmentassociatedwiththedeclaredemergency.B.Ifareleaseisoccurring,eventhoughitmaybelessthannormaloperatinglimits,checkbox"B."
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:57of66ATTACHMENT28DIRECTIONSFORCOMPLETINGTHEFLORIDANUCLEARPLANTEMERGENCYNOTIFICATIONFORM(Page4of6)10.(continued)C.Ifareleasehasoccurredbutstopped,checkbox"C."SpecificdoseinformationshouldbesuppliedonthesupplementaldatasheetaftertheTSCisdeclaredoperationalatanAlertorhigherclassification.4DoseAssessmentpersonnelintheTSCorEOFwillhavethisinformation.TheTSCChemistrySupervisor,TSCHPSupervisororEOFHPManagershouldbecontactedforthedata.11.OffsiteReleaseSinificanceCateoDoNotCheckAnyBoxinItem11ifyouCheckedBox10"A"NoReleaseA.Ifareleaseisoccurringorhasoccurred,anddoseinformationisnotavailableatthetimeofnotification,checkbox"A"andfollowupassoonasinformationbecomesavailable.B.Checkbox"B"ifbothnoblegasandiodinereleaseratesarelessthanorequaltothefollowing:NobleGasrelease<3.5E+5uci/sec(3.5E-1ci/sec)Iodinerelease<4.6E+1uci/sec(4.6E-5ci/sec)C.Checkbox"C"ifeithernoblegasoriodinereleaseratesexceedthevaluesin"B"(above)butforecasted1miledosesarelessthaneither500mremTEDEor1000mremThyroidCDE.Thesedosesarelessthanthestate'sProtectiveActionGuide(PAG)levels.D.Checkbox"D"ifforecasted1miledosesaregreaterthanorequaltoeither500mremTEDEor1000mremThyroidCDE.ThesePAGlevelsrequirestateandcountyaction.
REVISIONNO.:PROCEDURENo.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONS'T.LUCIEPLANTPAGE:58of66ATTACHMENT2BDIRECTIONSFORCOMPLETINGTHEFLORIDANUCLEARPLANTEMERGENCYNOTIFICATIONFORM(Page5of6)12.UtiliRecommendedProtectiveActionsA.Iftherearenoprotectiveactionrecommendations(PARs),checkBox"A."B.ThisboxpertainstoCrystalRiverormaybeusedbyoff-siteagenciesandshouldnotbeusedbyFPL.IfPARsarenecessary,thencheckBox"C."DetermineappropriatePARsusingtheguidanceinyourfacility'sappendixinthisprocedure.CopythePARsintoitem12"C."IndicatePARsusingonlythewordsNONE,ALL,ALLREMAININGorbylistingthelettersofthesectorsaffected.ProtectiveActionRecommendationsshallbeapproved,bytheEmergencyCoordinator(EC)ortheRecoveryManager(RM).13.HasEventBeenTerminated?A.Checkbox"A"iftheeventhasnotbeenterminated.DONOTENTERATIMEORDATE.B.Checkbox"B"iftheeventhasbeenterminatedandenterthetimeanddateoftermination.TheEChasthisinformation.14.SulementalFormIsAttached?A.Checkbox"A"unlessaSupplementalFormhasbeencompletedforthisparticularmessage.B.Checkbox"B"ifaSupplementalFormisaccompanyingthismessage.TheEmergencyCoordinator(EC)orRecoveryManager(RM)shallsigntoindicateapprovaltotransmittheinformationcontainedontheformunlessthesecondpage(SupplementalDataSheet)issignedforatwo-pagenotification.TheECorRMApprovalSignaturelineisnotnumberedbecausethestateandcountiesdonotneedthisinformation.DONOTATTEMPTTOTRANSMITTHISINFORMATIONVIAHOTRINGDOWN.Thestateandcountyforms,towhichtheyarecopyingdata,donotcontainthissignatureline.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:59of66ATTACHMENT2BDIRECTIONSFORCOMPLETINGTHEFLORIDANUCLEARPLANTEMERGENCYNOTIFICATIONFORM(Page6of6)15.MessaeReceivedBEnterthenameoftheStateWarningPointDutyOfficerortheindividualthatreceivesthenotification.EnterthetimeattheStateWarningPoint(requestitfromtheDutyOfficer)andindicatethedatethecalliscompleted.ENDOFATTACHMENT2B REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:60of66ATTACHMENT2CDIRECTIONSFORCOMPLETINGTHESUPPLEMENTALDATASHEET(Page1of3)"SupplementtoMessageNumber"isthesamenumberrecordedin2."C"ontheFloridaNuclearPlantEmergencyNotificationFormassociatedwiththisSupplementalDataSheet.PlantConditionsInformationCriticalSafetFunctionsAnswerthethreequestions'yes"or"no"bycheckingtheappropriatebox.A.Isthereactorshutdown?B.Isthecoreadequatelycooled?C.Isthereadequateemergencypoweravailable(diesels)?FissionProductBarrierStatusCheckoneconditionforeachbarrier-intact,challenged,lost,orregained."CompletedBy"shouldbefilledinbythepersonrecordingtheinformationonthisformbyprintingtheirnameonthisline.RadioloicalDoseAssessmentData(ToBeObtainedfromDoseAssessmentPersonnel)NOTEIftheClassAModelisbeingused,a'SupplementalDataSheet-RadiologicalDoseAssessmentData'ormisavailablewhichprovidesinformationforcompletionofitems1-5.TheinformationisinaformatsimilartothatfoundontheSulementalDataSheet.ReleaseStatusA.Iftherearenoindicationsofaradioactiverelease,checkbox"A."B.Ifareleaseisoccurring,eventhoughitmaybelessthannormaloperatinglimits,checkbox"B."C.Ifareleasehasoccurredbutstopped,checkbox"C."Arelease(duringanydeclaredemergency)isdefined>as:~Anyeffluentmonitorincreaseof(approximately)10timesoronedecadeabovepre-transientvaluesOR~HealthPhysicsdetectingairborneradioactivitylevelsinexcessof25%derivedairconcentration(DAC)outsideofplantbuildingsduetofailureofequipmentassociatedwiththedeclaredemergency.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:61of66ATTACHMENT2CDIRECTIONSFORCOMPLETINGTHESUPPLEMENTALDATASHEET(Page2of3)2.ReleaseRateThissectionrequiresthecompletedresultsofdoseassessment.A.Checkthenoblegasboxforanoblegasrelease.Writethereleaserate(incuriespersecond)inthespaceprovided.Checkeither"Measured"or"Default"toindicatehowthereleaseratewasdetermined.B.Checktheiodinesboxforaniodinerelease.Writethereleaserate(incuriespersecond)inthespaceprovided.Checkeither"Measured"or"Default"toindicatehowthereleaseratewasdetermined.45.T~f~ICheckthetypeofrelease-eitherairborneorliquid.Enterthetimeanddatethatthereleasestartedandstopped.Pro'ectedOff-SiteDoseRateThissectionrequiresthecompletedresultsofdoseassessment.EntertheprojectedThyroidDoseRate(CDE)andtheTotalDoseRate(TEDE)inmrem/hrforthesiteboundary,2,5,and10miledistances.WeatherDataA.WindDirectionFrom-EnterthewinddirectionusedbyDoseAssessor.NOTEThew'inddirectioncanbeobtainedfromERDADSbydepressingthe"EPIP"key,onthetoprowofthekeyboard,orbycheckingtheMetTowerIndicatorPanelonUnit1.Iftheindicationisgreaterthan360'hewinddirectionwouldbedeterminedbysubtracting360fromtheindicatednumber.Winddirectioncanberoundedtothenearestwholenumber.B.WindSpeed-EnterthewindspeedusedbyDoseAssessor.ThewindspeedcanbereadfromERDADS(ortheMETTowerIndicatorPanelonUnit1).C.StabilityClass-EnterthestabilityclassdeterminedbyDoseAssessor.FigurebelowshowstheDelta-T(60metertemperatureminus10metertemperature)usedtofindstabilityclass.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:62of66ATTACHMENT2CDIRECTIONSFORCOMPLETINGTHESUPPLEMENTALDATASHEET(Page3of3)5.(continued)IfDelta-TisIslessthanoreualto-1.7-1.6To-1.5-1.4-1.3To-0.5-0.4To+1.4+1.5To+3.6reaterthan+3.6ThenStabiliClassisADGCompletingtheSupplementalDataSheetCompletedBy:Thepersoncompletingtheformshouldprinttheirnameonthisline.ApprovalneedstobesignedbytheECorRMwhoapprovestheforms.TheECorRMshallsigntoindicateapprovaltotransmittheinformationcontainedontheforms.TheSupplementalDataSheetsignature,foratwo-pagenotification,indicatesapprovalofboththefirstandsecondpages.Onatwo-pagenotificationtheECorRMonlyneedsignthesecondpagetoapproveboththeFloridaNuclearPlantEmergencyNotificationFormandtheSupplementalDataSheet.The"EmergencyCoordinatororRecoveryManagerApproval"linesarenotnumberedbecausethestateandcountiesdonotneedthisinformation.DONOTATTEMPTTOTRANSMITTHISINFORMATIONVIAHOTRINGDOWN.Thestateandcountyforms,towhichtheyarecopyingdata,donotcontaintheselines.ENDOFATTACHMENT2C REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:63of66ATTACHMENT3$8NRCREACTORPLANTEVENTNOTIFICATIONWORKSHEET(Page1of2)NRCFORM361(12-2000)NOTIFICATIONTIMEREACTORPLANTEVENTNOTIFICATIONWORKSHEETFACILITYORORGANIZATIONUNITNAMEOFCALLERU.S.NUCLEARREGULATORYCOMMISSIONOPERATIONSCENTEREN¹CALLBACK¹EVENTTIME8aZONEEVENTDATEPOWERMODEBEFOREPOWERMODEAFTEREVENTCLASSIFICATIONS1-Hr.Non.Emeren10CFR50.72b1vASafeS/DCaabilitAINAGENERALEMERGENCYGEN/AAECTSDeviationADEVvBRHRCssbllitAINBSITEAREAEMERGENCYSIT/AAEC4-Hr.Non-Emerenc10CFR50.72b2vCControlofRadReleaseAINCALERTUNUSUALEVENTALE/AAECUNU/AAEC50.72NON.EMERGENCYseenextcolumnsPHYSICALSECURITY73.71DDDDiTSReuiredS/DASHUvDAccidentMitlation'INDivAECCSDlschaetoRCSACCSxllOffsiteMedicalAMEDivBRPSActuationscramARPSxiiiLossComm/Asmt/ResACOMxiOffsiteNotificatioAPRE60-Ds0tlonsl10CFR50.73a1MATERIAL/EXPOSUREFITNESSFORDUTY8???HFITS.Hr.NonEmerenc10CFR50.72b3InvalidSedfiedStemActuationAINAIADeradedConditionADEGOtherUnseclfledReulrementIdentlOTHERUNSPECIFIEDREQMT.seelastcolumniiBUnanaledConditionAUNANONRINFORMATIONONLYNNFivASedfiedSternActuationAESFNONRDESCRIPTIONIndude:Systemsaffected,actuatlonsandtheirinitiatingsignals,causes,effectofeventonplant,actionstakenorplanned,etc.(Continueonback)NOTIFICATIONSYESNOWILLBENRCRESIDENTSTATEsLOCALOTHERGOVAGENCIESMEDIA/PRESSRELEASEMODEOFOPERATIONUNTILCORRECTED:ESTIMATEDRESTARTDATE:ADDITIONALINFOONBACK0YES0NOANYTHINGUNUSUALORNOTUNDERSTOOD?0YES(Explslnsbove)0NODIDALLSYSTEMSFUNCTIONASREQUIRED?0NO(Explainabove)Form¹PSL-F080EPIP-08,Off-SiteNotificationsandProtectiveActionRecommendations,EffectiveDate:01/18/01andAP0010721,NRCRequiredNon-RoutineNotificationsandReports REVISIONNOJPROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:64of66ATTACHMENT3$8NRCREACTORPLANTEVENTNOTIFICATIONWORKSHEET(Page2of2)RADIOLOGICALRELEASES:CHECKORFILLINAPPLICABLEITEMSseclficdetails/exlanatlonsshouldbecoveredlneventdescrltlonLIQUIDRELEASEGASEOUSRELEASEMONITOREDUNMONITOREDPERSONNELEXPOSEDORCONTAMINATEDUNPLANNEDRELEASEPLANNEDRELEASEOFFSITERELEASET.S.EXCEEDEDOFFSITEPROTECTIVEACTIONSRECOMMENDEDONGOINGTERMINATEDRMALARMSAREASEVACUATED'StatereleaseathlndescrltronNobleGasIodineParticulateLiquid(excludingtritiumanddissolvednobleasesLIuldtritiumTotalActlvlReleaseRateCl/sec%T.S.UMITHOOGUIDETotalActlvlCl%T.S.LIMIT0.1Cl/sec10uCI/sec1uCI/sec10uCI/min0.2Cl/minHOOGUIDE1000Cl0.01CI1mCI0.1ClRADMONITORREADINGSALARMSETPOINTS%T.S.LIMITIfaIlcablePLANTSTACKCONDENSER/AIREJECTORMAINSTEAMLINESGSLOWDOWNOTHERRCSORSGTUBELEAKS:CHECKORFILLINAPPLICABLEITEMS:sselflcdetails/exlanatlcnsshouldbecoveredIneventdescrltlonLOCATIONOFTHELEAK(e.g.~SG//,valve,pipe,etc.)LEAKRATEUNITS:gpm/gpdT.S.LIMITSSUDDENORLONG-TERMDEVELOPMENTLEAKSTARTDATETIMECOOLANTACTIVITYPRIMARYANDUNITS:SECONDARYLISTOFSAFETYRELATEDEQUIPMENTNOTOPERATIONAl.EVENTDESCRIPTION(Continuedfromfront)Form¹PSL-F080EPIP-08,Off-SiteNotificationsandProtectivoActionRecommendations,andAP0010721,NRCRequiredNon-RoutineNotificationsandReportsEffectiveDate:01/18/01ENDOFATTACHMENT3 REVISIONNO.:PROCEDURENo.:EPIP-08PROCEDURETITLE:rOFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:65of66A.tt7ATTACHMENT3ADIRECTIONSFORCOMPLETINGTHENRCREACTORPLANTEVENTNOTIFICATIONWORKSHEET(Page1of2)Contactinformation-tobecompletedfollowingcontact1~NameofthepersoncontactingtheNRCorotherdesignatedFPLcontact.2.NRCContactsName-willbeprovideduponcontact.AlsoobtaintheeventnumberandnotificationtimeasreceivedfromtheHOOshouldberecordedonthetopoftheworksheet.B.ReactorPlantEventNotificationWorksheet,Page1NOTEThe"EN¹"isrovidedbtheNRC.NotificationTime-enterthetimecontactismade.2.Unit-entertheappropriateunitnumber:Enter"0"foraclassificationcommontobothunits.3.4.5.7.CallersName-enterthenameofthepersonmakingthecallCallback¹-enterthenumberoftheENSphonethatyouarecallingfromandthecommercialphonenumberatwhichyoucanbereached.EventtimeandZone-enterthemilitarytime,thezonewillbe"EST"forEasterStandardTimeor"EDT"forEasternDaylight-savingsTime.EventDate-enterthedatetheeventisoccurring.Power/ModeBefore8Power/ModeAfter-enterthepowerinpercentandthemodenumber(1-6)beforeandaftertheevent.NOTEAbbreviations/acronyms(e.g.,UNU/AAEC,SIT/AAEC,etc.iareforNRCuseonl.8.EventClassifications-checkoneofthefourblocksforGeneralEmergency,SiteAreaEmergency,Alert,orNotificationofUnusualEvent.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:66of66QpATTACHMENT3ADIRECTIONSFORCOMPLETINGTHENRCREACTORPLANTEVENTNOTIFICATIONWORKSHEET(Page2of2)B.(continued)NOTENootherblocksintheuerhalfoftheformarereuired.9.Description-provideawrittendescriptionoftheevent.NOTEChecktheblocksinthelowerortionoftheformbasedoncurrentconditions.C.10.Modeofoperationuntilcorrected-providedifknown.11~Estimateforrestartdate-enter"unknown".12.AdditionalinfoonPage2-enteryesorno.ReactorPlantEventNotificationWorksheet,Page2Fillinasmuchoftheinformationontheformasisimmediatelyavailable-donotcreateunduedelayinmakingthenotification.Thisinformationcanbegainedoncetheopenlineofcommunicationisestablished.ENDOFATTACHMENT3A
Title:FPLST.LUCIEPLANTEMERGENCYPLANIMPLEMENTINGPROCEDURESAFETYRELATEDProcedureNo.EPIP-09CurrentRevisionNo.EffectiveDate03/09/01OFF-SITEDOSECALCULATIONSResponsibleDepartment:EMERGENCYPREPAREDNESSREVISIONSUMMARY:Revision4-Revisedfanflowratestoaccommodateformaintenanceacceptancecriteriaandincludedminorcorrectiontoanumberusedinanexample.(SteveKnapp,02/02/01)Revision3-Madehumanfactorsimprovements;identifiedapplicableunit,relocatednoteandcautionmessages,changedtable,revisedinstructionsforchangingdateandtimeonClassAcomputer,andchangedresponsibledepartmentfromTrainingtoEmergencyPreparedness.(SteveKnapp,09/11/00)Revision2-RevisedprocedurenumbertoaddressQA.commentfromperiodicreview(AppendixJ).(J.R.Walker,03/18/99)PSLOOOO(PROCEDUREPRODUCTIONRevision4FRGReviewDate02/01/01RevisionFRGReviewDate012/15/97ApprovedByJ.ScarolaPlantGeneralManagerApprovedByR.G.WestPlantGeneralManagerN/ADesignatedApproverN/ADesignatedApprover(MinorCorrection)ApprovalDate12/15/97ApprovalDate02/02/01QPSDATEDOCTPRQGEDUREDQCNEPIP<9SYSCOMCOMPLETEDITM4 0l' REVISIONNO.:PROCEDURENO.:EPIP-09SECTION1.0PURPOSEPROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTTABLEOFCONTENTSPAGE:2of74PAGE
2.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTS.......43.0RESPONSIBILITIES4.0DEFINITIONS5.0INSTRUCTIONSATTACHMENTSATTACHMENT1METEOROLOGICALDATA.....ATTACHMENT2RELEASERATEDATAATTACHMENT3DOSECALCULATIONWORKSHEETATTACHMENT4TSC/EOFDOSEASSESSMENTGUIDANCEFORRESPONDINGTOANUNMONITOREDCONTAINMENTBURPATTACHMENT5ESTIMATEOFCONTAINMENTE%MASSLOSS".........1626.45.5563ATTACHMENT6FIELDTEAMMEASUREMENTSASSESSMENT....ATTACHMENT7OFF-SITECALCULATIONS-CLASSACOMPUTERMETHOD....~...65.68 P
REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:3of741.0PURPOSE1.1DiscussionThisprocedureisapplicabletobothUnit1andUnit2.Shouldbothunitsbeaffected,provisionshavebeenmadeontheworksheetstosumthereleaserates.2.3.TheChemistryDepartment,asdirectedbytheEmergencyCoordinator,(EC)orhisdesignee,shallperformoff-sitedosecalculationsinaccordancewiththisprocedureuntiltheTechnicalSupportCenter(TSC)orEmergencyOperationsFacility(EOF)ismannedandoperational.Off-sitedosecalculationsandassessmentshallbeperformedintheEOFwhenitismannedandoperational.TheTSCmaycontinuetoperformdoseassessmentandcompareresultswiththedoseassessmentgroupintheEOF.4.Theoff-sitedoseestimates,releaseratesandradiationlevelsincontainmentareusedbytheECforemergencyclassificationoroff-siteProtectiveActionRecommendations(PARs).5.6.ThisprocedurehasanAttachment4,TSC/EOFDoseAssessmentGuidanceforRespondingtoanUnmonitoredContainmentBurp,forusebyTSCand/orEOFdoseassessmentpersonneltoassessunmonitoredreleasesresultingfromrapidcontainmentdepressurizationevents.Attachment5,EstimateofContainmentVolumeLoss,addressesarapiddepressurization(i.e.,greaterthandesignbasis)ofcontainmentthroughanestimateofcontainmentvolumeloss.7.8.Attachment6,ReleaseRatefromFieldTeamMeasurements,isalsoincludedwhichprovidesamethodtobackcalculateareleaseratefromFieldMonitoringTeamsurveyresults.AcomputerdosecalculationmodelisavailableforusebydoseassessmentpersonnelinboththeTSCandEOF.Thismodelestimatesoff-sitedoseratesandcumulativedoses.Themodelparallelsthisprocedure.InstructionsforuseofthecomputermodelareprovidedinAttachment7,Off-siteDoseCalculations-ClassAComputerMethod.
REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:4of7
42.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTSNOTEOneormoreofthefollowingsymbolsmaybeusedinthisprocedure:IndicatesaRegulatorycommitmentmadebyTechnicalSpecifications,ConditionofLicense,Audit,LER,Bulletin,OperatingExperience,etc.andshallNOTberevisedwithoutFacilityReviewGroupreviewandPlantGeneralManagerapproval.Indicatesamanagementdirective,vendorrecommendation,plantpracticeorothernon-regulatorycommitmentthatshouldNOTberevisedwithoutconsultationwiththeplantstaff.'PIndicatesastethatreuiresasinoffonanattachment.2.1References1~St.LuciePlantUpdatedFinalSafetyAnalysisReport(UFSAR),Unit1andUnit22.St.LuciePlantRadiologicalEmergencyPlan(E-Plan)3.E-PlanImplementingProcedures(EPIP-00-13)4.HP-2,FP8LHealthPhysicsManual5.QI-17-PSL-1,QualityAssuranceRecords6.BasesforAccidentDoseCalculationsforSt.LucieNuclearPowerPlant(BasespreparedbyHMMAssociatesofWaltham,Massachusetts)7.NUREG-0654,Rev.1,FEMARep-1,CriteriaforPreparationandEvaluationofRadiologicalEmergencyResponsePlansandPreparednessinSupportofNuclearPowerPlants,November,19808.NUREG/BR-150,Vol.1,ResponseTechnicalManual9.EPA-400-R-92-001,EPAManualofProtectionActionGuidesandProtectiveActionsforNuclearIncidents,October,1991.10.g2FPLEngineeringCalculationPSL-BFJM-93-032,March,1994.
REVISIONNO.:PROCEDURENo.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:5of742.2RecordsRequiredAllcompleteddata/worksheetsorcomputergeneratedformsprovidingsimilarinformation,shallbemaintainedintheplantfilesinaccordancewithQI-17-PSL-1.2.3CommitmentDocuments1.g~ConditionReport96-2609(ERDADSData/FanStatus)2.g3PMAIPM99-09-016(PARsBasedonFMTData)3.g4ConditionReport00-1426Supplement1(FanFlowrates)
REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:6of743.0RESPONSIBILITIES3.1TheChemistryDepartmentshallberesponsibleforperformingoff-sitedosecalculations,whendirectedbytheEmergencyCoordinator.3.2TheEOFDoseAssessorshalltakeprimaryresponsibilityfordoseassessmentwhentheEOFisoperational.4.0DEFINITIONS4.1Abbreviations/AcronymsPAR-ProtectiveActionRecommendation-designationusedontheDoseCalculationWorksheetthatreferstodatathatshouldbeusedwhendeterminingProtectiveActionRecommendations.2.SNF-StateNotificationForm-designationusedontheDoseCalculationWorksheetthatreferstodatathatshouldbetransferredtotheStateNotificationForm.4.2AffectedUnit-(forpurposesofthisprocedure)-areactorunitthathasactivatedtheEmergencyPlanandhasarelease.4.3IodineRemovalSystem-isdefinedasanyoneContainmentSprayoccurringwithitschemicaladditionsysteminjectingthechemicals:Unit1-SodiumHydroxideUnit2-Hydrazine4.4ParticulateFactor(PF)-afactorusedwhencoremeltoroverheatisunderwaytoaccountfortheparticulateinthereleasepathway.4.5Release-duringanydeclaredemergency,oneofthefollowingistrue:Anyeffluentmonitorincreaseof(approximately)10timesoronedecadeabovepre-transientvaluesOR2.HealthPhysicsdetectingairborneradioactivitylevelsinexcessof25percentDerivedAirConcentration(DAC)outsideofplantbuildingsduetofailureofequipmentassociatedwiththedeclaredemergency.
REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:7of744.6Symbols-thefollowingsymbolsareusedinthisprocedure:1.(=lessthan2.(=lessthanorequalto3.4.5.)=greaterthan)=greaterthanorequaltoE=standsforexponentandindicatesthepowertowhich10israised,"ortimes10tothepowerof',e.g.:A.E+04=10"=10,000B.E-04=10=0.0001 REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:Sof745.0INSTRUCTIONSCAUTION1.LargeerrorsmayresultiftheERDADScomputerisNOTaddressingtheaffectedunit'sdatabase.tt~2."Nodata"afteraparameternamemeansthatthisinputisNOTavailablefromERDADSforthisunit.5.1DataAcquisitionERDADS-EmergencyResponseDataAcquisitionandDisplaySystem,thefollowinginformationisavailableonthedisplayscreensindicated.A.MeteorologicalData-Display:SMD(SiteMeteorologicalData)B.PlantParameterData-CAUTION$~Certainparameters(e.g.,fanstatus)availableonUnit2areNOTavailableonUnit1.C.Display:intheTSC-SF(1/2)(SafetyFunctionsandEquipmentStatus)intheEOF-EF(1/2)RadiologicalData-Display:RG(1/2)(RadiationGaseousSourceTerm)RBS(HealthPhysicsEvaluationScreen-containmentradiationlevelsandtrends)R11R21(AreaRadiationMonitors,Unit1)(AreaRadiationMonitors,Unit2)
REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:9of745.1DataAcquisition(continued)(continued)D.ChemistryData-Display:,R12(S/GBlowdown,SteamJetAirEjector,Unit1)R22(S/GBlowdown,SteamJetAirEjector,Unit2)E.Toaccessdata-1.Press"CLEAR"2.Typein"PupUnit(1/2)"3.Press"EXEC"ute,topofscreenwillread"Unitchangeiscomplete"or"CurrentUnitissameasenteredUnit"4.Press"EPIP"5.The"PAGEUP"and"PAGEDOWN"keyswillcausethefollowingdisplaysequence:SMD-RG(1/2)-SF(1/2)-RBS-EF(1/2)-SMDF.Togodirectlytoascreen-1.Press"CLEAR"2.Typeinscreendesignation,e.g.,"RG1"3.Press"DISPLAY"2.Sound-poweredPhoneTalker-theSound-poweredPhoneTalkercanbeutilizedasaprimarysourceofinformationorasanalternatemethodtoERDADS.A.Primarysource-statusoffansneededfordoseassessmentexhaustfans6,7,8,9,10,15,16and17.
REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:10of745.1DataAcquisition(continued)3.Unit1determinegrossNoblegasconcentrationsviaEberlineControlTerminalAorB:A.Enterthefollowingsequenceonthekeypadforeachapplicablechannelnumber:1~Press10MINHIST2.Determinetheapplicablepathwaychannelnumberfromthetablebelow:3.Entertheapplicablepathwaychannelnumber4.PressENTER(valueappearsinwindow)5.PressPRINT6.PressFILE7.PressENTER8.Enterthenexttolastpointfromthelowestnon-alarmingrangeintotheapplicableDatacolumninstep6.NOTEUseasteamlinechannelONLYiftheSafetiesand/orAtmosphericSteamDumsarereleasinsteam.Monitorshaveonerane.PathPlantVentECCS-A.ECCS-B.~.FuelBldg.SteamlineA.SteamlineB.Low1-52-53-54-5~~N/AN/ARangeMidHi1-71-92-72-93-73-94-74-95-1N/A5-2N/A REVISIONNO.:PROCEDURENo.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:11of745.1DataAcquisition(continued)4.Unit2determinegrossNoblegasconcentrationsviathePC-11,RadiationMonitoringConsole.Usethefollowingkeystrokesequenceforeachapplicablechannelnumber:aA.PressKeyF8todisplayControlMenuB.C.D.E.UsetheARROWKeytohighlighttheRM-80UtilityTaskunderthestatusdisplayPressENTERkeyPressKeyF1toselectHistoricalDisplayPressKeyF4toselectGraph10MinuteNOTEStartwithlowestscalenotinalarm.F.Determinetheapplicablepathwaychannelnumber,fromthetablebelow:G.Atprompt,typeMandtheChannelNumber(seebelow)H.PressENTERI.RecordTopC1readinginapplicableDATAcolumn.J.PressKeyF10K.PressKeyF10 REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:12of745.1DataAcquisition(continued)4.(continued)L.PressKeyF1todisplayAllMonitorSchematicAlicablePathwaChannelNumberNOTEUseasteamlinechannelonlyiftheSafetiesand/orAtmosphericSteamDumpsarereleasingsteam.Monitorshaveonerange.UseNETvalueChannel-Backround.PathPlantVentECCS-A.ECCS-B..FuelBldg.(IfNOTdiverted)...~..~....~.SteamlineA.SteamlineB..Background(Steamline).RangeLowMid621622601602611612413NIANIA631NIA632N/A633Hi623603613N/ANIAN/AN/AENDOFSECTION5.1
REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:13of74CAUTIONWindspeed,winddirectionandDeltatemperaturevaluesshouldvarywithtime,i.e.,chartrecordersintheUnit1ControlRoomandA1ASiteTowerShackshouldNOTbestraight-lining.Ifinitialeffortstocorrectstraight-liningfail,alternatesourcesofdata(describedbelow)maybeusedinlieuofstraiht-linindata.NOTESection5.2through5.5provideamethodforestimatingTotalDose(TEDE)andThyroidDose(CDE)doseratesandprojectedTotalDose(TEDE)andThyroidDose(CDE)dosesviahandcalculations.TheClassAcomputermethodmaybeusedinlieuofhandcalculationsinaccordancewithAttachment7.5.2CompleteONEDataSheetfromAttachment1,MeteorologicalData,selectedfromoneofthethreeprioritizedmethodslistedbelow.PrimaryMethodDataSheet1-SITETOWERTheERDADSterminals,Unit1ControlRoomandsitetowerchartrecordersprovide15minuteaveragedata.OR1stalternateDataSheet2-NOANNWSThisprimarybackupisforuseifsitetowerdataisNOTavailable.OR2ndalternateDataSheet3-DEFAULTForuseifbothsitetowerandNOAA/NWSdataareNOTavailable.5.3TheDOSECALCULATIONWORKSHEETisdeterminedaspartofcompletingoneoftheMeteorologicalDataSheets.TheDoseCalculationWorksheetwillbeusedtodeterminedosesaftertheReleaseRateWorksheetiscompleted.
REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:14of74NOTEifbothunitsareinadeclaredemergencyandbothunitshaveorhadarelease,thenthesitereleaserateisthesumofbothunits'eleaserates.NOTETOTSC/EOFDOSEASSESSMENTPERSONNELArapid,unexplainedcontainmentpressurereduction(NOTduetooperationofspray,additionalcoolers,etc.)mayindicateanunmonitoredrelease.Foruidanceinresondintothisevent,refertoAttachment4.5.4DeterminethesitereleaseratebycompletingONEDataSheetfromAttachment2,ReleaseRateData,foreachaffectedunit.Fortheaccidenttype,selecttheDataSheet(s)fromthefourprioritizedmethodslistedbelow.Primarymethod,CHEMISTRYGRABSAMPLINGAllaccidentsforUnit1:DataSheet1AforUnit2:DataSheet2AOR1stalternate,AllaccidentsEFFLUENTMONITORSforUnit1:DataSheet1BforUnit2:DataSheet2BOR2ndalternate,LOCAOnlyCONTAINMENTHI-RANGERADIATIONMONITOReitherUnit:DataSheet3ORPOSTLOCAMONITORS,eitherUnit:DataSheet4OR3rdalternate,AllaccidentsDEFAULT,onlyifnoothersourceofdataisavailableeitherUnit:DataSheet5 REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:15of745.5CalculatetheoffsitedoseratesandprojecteddosesbyfollowingtheinstructionsontheselectedDataSheetofAttachment3,DOSECALCULATIONWORKSHEET.5.6TheEmergencyCoordinatorshallbeprovidedwithdosecalculationresultsastheyarepreparedintheTSC.5.7TheRecoveryManager(RM)shallbeprovidedwithdosecalculationresultsastheyarepreparedintheEOF.5.8TheTSCChemistrySupervisor(EOFHPManagerwhenEOFoperational)shouldmonitorreleaseratesandmeteorologicalconditionstodeterminehowfrequentlytoupdatethedoserateestimates.Releaseanddoseestimatesshallberevisedatleasthourlyforthefirst8hoursaftertheaccidentunlessitisdeterminedthatreleasesofradioactivityhavebeenterminated.Whendoinghandcalculations,Ifanyofthefollowingaverageschangebytheamountsindicatedbelow,overaperiodof30minutesorless,Thendoseestimatesshallbeupdated.A.Releaseratesincreasebymorethan25percent.ORB.Windspeeddecreasestolessthanonehalfofpreviousvalue.ORC.Atmosphericstabilitybecomesmorestablebymorethanoneclass(e.g.,changefromstabilityDtoF).ORD.Winddirectionchangesbymorethan22.5degrees(i.e.,plumecenterlineismorethanonesectorawayfrompriorlocation).ENDOFSECTION5.0 REVISIONNo.:PROCEDURENo.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:16of74ATTACHMENT1METEOROLOGICALDATA(Page1of10)DATASHEET1SITETOWER(Page1of3)GatherData:A.Date&TimeofmeteorologicalobservationsB.Enter10Meter(alternate60Meter)WINDSPEED:mphC.Enter10Meter(alternate60Meter)WINDDIRECTION(from)deg.2.D.EnterDelta-T(60Meterminus10Metertemperatures)UsingDelta-T(aT)andtheguidebelow,determineandentertheStabilityClassdeg.FIfDELTA-Tislessthanorequalto-1.7-1.6to-1.5-1.4-1.3to-0.5-0.4to+1.4+1.5to+3.6greaterthan+3.6ThenStabilityClassisAG REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:17of74ATTACHMENT1METEOROLOGICALDATA(Page2of10)DATASHEET1SITETOWER(Page2of3)3.Usingtheguidebelow,determineandcircletheAFFECTEDSECTORS.NOTEifthewinddirectionisdirectlyontheedgeoftwosectors(e.g.,11',33',56',etc.),anadditionalsectorshouldbeaddedtotheProtectiveActionRecommendation(PAR).Forexample,ifthewinddirectionisfrom78',thentheaffectedsectorsforthePARshouldbeL,M,NandP.WindFrom348-1111-3333-5656-7878-101101-123AffectedSectorsHJKJKLKLMLMNMNPNPQWindFrom123-146146-168168-191191-213213-236thereisnoAffectedSectorsPQRQRARABABCBCD0sectorWindFrom236-258258-281281-303303-326326-348thereisnoAffectedSectorsCDEDEFEFGFGHGHJIsector REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTATTACHMENT1METEOROLOGICALDATA(Page3of10)DATASHEET1SITETOWER(Page3of3)PAGE:18of744.CheckforSeaBreezeeffect:OnlyifAllofthefollowingconditionsaremet,thentheSeaBreezeeffectisYESIfoneormoreconditionsarenotmet,thentheSeaBreezeeffectisNOStabilityClassA,BorCTimeofday6AMto7PMWindDirection(from)isbetween0throughEASTto180degrees10meterairtemperaturegreaterthanHISTORICALAVERAGESURFACEWATER,listedbelow:JANFEBMARAPRMAYJUNJULAUGSEPOCTNOVDEC696569737679808181797471SeaBreezeImpact(YesorNo)5.Usingtheguidebelow,selectaDOSECALCULATIONWORKSHEET:Stab.SeabreezeDoseGaleCtass~lmactWorksheetAYES1ANO2BYES3BNO4Stab.SeabreezeDoseGaleClass~lmactWorksheetYESNOStab.DoseGaleClassWorksheetD7E8F9G106.CopyinformationtotheselectedDOSECALCULATIONWORKSHEET:A.WINDDIRECTIONandtheAFFECTEDSECTORStolineAB.WINDSPEEDtoline27.Thisdatasheetiscompleted,proceedtoreleaseratedetermination.ENDOFDATASHEET1 REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:19of74ATTACHMENT1METEOROLOGICALDATA(Page4of10)DATASHEET2NOAA/NWS(Page1of6)GatherData:CallNOAA/NationalWeatherService(NWS)station(phonenumberintheSt.LuciePlantEmergencyResponseDirectory,Section4.0,Off-siteSupport.WhentheNOAApersonanswers,identifyFPL-St.LuciePlantascallingpartyandobtain:A.Date/Timeofobservation:EasternStandardTimeDaylightSavingsTime(circleeasternordaylight)B.WINDDIRECTION(From):DegreesC.WINDSPEED:D.Sunrise:KnotsamSunset:pmE.SkyCondition:ClearScatteredOvercastBroken(clrcie)F.Ifskyconditionisovercastorbroken,thenenterCeilingHeightG.EstimatedairtemperatureforFt.PierceareaOFH.Iftimepermits,askforaweatherforecastforthearea:2.DetermineandcircletheSolarRadiationCharacteristic(nil,weak,slight,etc.):A.IFDaytime(1houraftersunriseto1hourbeforesunset),THENDetermineSolarAltitudefromFigure1(attheendofthisdatasheet),usingtimeanddate.
REVISIONNO.:PROCEDURENo.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:20of742.A.(continued)ATTACHMENTIMETEOROLOGICALDATA(Page5of10)DATASHEET2NOAA/NWS(Page2of6)'.CircletheSolarRadiationCharacteristiconthetablebelow,usingSkyCondition,CeilingHeightandSolarAltitude.DaySkyConditionCeiling,FeetSolarAltitude<15deg15to<35deg35to60deg>60degOvercastBrokenClearScattered<70007Kto16K>16000<70007Kto16K>16000notapplicableNilWeakWeakWeakWeakWeakWeakNilWeakWeakWeakWeakSlightSlightNilWeakSlightWeakSlightModerateModerateNilSlightModerateSlightModerateStrongStrongB.IFNOTDaytime,circletheSolarRadiationCharacteristiconthetablebelow,usingSkyConditionandCeilingHeight(SolarAltitudeisnotapplicable).NightSkyConditionOvercastBrokenClearorscatteredCeiling,Ft.lessthan70007000orhighernotapplicablenotapplicableSolarRadiationCharacteristicNilWeakLossWeakLossStrongLoss REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:21of74ATTACHMENT1METEOROLOGICALDATA(Page6of10)DATASHEET2NOAA/NWS(Page3of6)3.UsingtheWindSpeedinKnotsandtheSolarRadiationCharacteristic,findinthetablebelowandcircletheStabilityClass.SolarRadiationWindSpeedinKNOTSStrongModerateSlightWeakNilWeakLossStrongLoss0-1)1-3AAABBBCCDDFFGG)3-5A)5-6)6-7)7-9)9-10)10-11)114.Usingtheguidebelow,determineandcircletheAFFECTEDSECTORS.NOTEIfthewinddirectionisdirectlyontheedgeoftwosectors(e.g.11',33',56,etc.),anadditionalsectorshouldbeaddedtotheProtectiveActionRecommendation(PAR).Forexample,ifthewinddirectionisfrom78',thentheaffectedsectorsforthePARshouldbeL,M,NandP.WindFrom348-1111-3333-5656-7878-101101-123AffectedSectorsHJKJKLKLMLMNMNPNPQWindFrom123-146146-168168-191191-213213-236thereisnoAffectedSectorsPQRQRARABABCBCD0sectorWindFrom236-258258-281281-303303-326326-348thereisnoAffectedSectorsCDEDEFEFGFGHGHJIsector REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:22of74ATTACHMENT1METEOROLOGICALDATA(Page7of10)DATASHEET2NOAAlNWS(Page4of6)5.CheckforSeaBreezeeffect:OnlyifALLofthefollowingconditionsaremet,thentheSeaBreezeeffectisYES.Ifoneormoreconditionsarenotmet,thentheSeaBreezeeffectisNO.StabilityClassA,BorCTimeofday6AMto7PMWindDirection(from)isbetween0throughEastto180degrees10meterairtemperaturegreaterthanHISTORICALAVERAGESURFACEWATER,listedbelow:JANFEBMARAPR69656973MAYJUN7679JULAUG8081SEPOCT8179NOV74DEC71SeaBreezeImpact(YesorNo)6.Usingtheguidebelow,selectaDOSECALCULATIONWORKSHEET(Attachment3):Stab.SeabreezeDoseGaleClass~lmactWorksheetAYES1ANO2BYES3BNO4Stab.SeabreezeDoseGaleClass~lmactWorksheetYESNOStab.DoseGaleClassWorksheetD7E8F9G10 REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:23of747.ATTACHMENTIMETEOROLOGICALDATA(Page8of10)DATASHEET2NOAA/NWS(Page5of6)CopyinformationtotheselectedDOSECALCULATIONWORKSHEET:A.Fromline1B,copytheWINDDIRECTIONtolineAofDoseCalculationWorksheet.B.1.Fromline1C,multiplythewindspeedinknotsby1.15toobtaintheWINDSPEED:mph2.CopyWINDSPEEDinmphtoline2ofDoseCalculationWorksheet.C.Fromline4,copytheAFFECTEDSECTORStolineAofDoseCalculationWorkshect.8.Thisdatasheetiscompleted,proceedtoreleaseratedetermination.
REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:24of74ATTACHMENT1METEOROLOGICALDATA(Page9of10)DATASHEET2NOAA/NWS(Page6of6)FIGURE1.SOLARALTITUDElUUtg0tCVt-CIl8ll'tl'lUh~ttIOK+Ul0l=at-KPUZ00V,O=Ih=-Vt)gU.0lUlt>.U.lUlUoott~~COltKCo)tO-IDO-:='Vt=Ou.l-W0+0lUl(gVCo0)g0t-OlI-CVCIlgoC'CUh0:ENDOFDATASHEET2 REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTATTACHMENT1METEOROLOGICALDATA(Page10of10)DATASHEET3DEFAULT(Page1of1)PAGE:25of74NOTEThismethodistobeusedonlyifSiteMetTowerandNOAAJNWSdataarenotavailable.1.IfDaytimeHours(1houraftersunriseto1hourbeforesunset)ThenselectDOSECALCULATIONWORKSHEET7andA.EnterAFFECTEDSECTORS=ALLinlineAB.CheckDefaultmethodinlineAC.EnterWINDSPEED=5mphinline2.2.IfNotDaytimeThenselectDOSECALCULATIONWORKSHEET9andA.EnterAFFECTEDSECTORS=ALLinlineAB.CheckDefaultmethodinlineAC.EnterWINDSPEED=3mphinline2.Thisdatasheetiscompleted,proceedtoreleaseratedetermination.ENDOFDATASHEET3ENDOFATTACHMENT1 REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTATTACHMENT2RELEASERATEDATA(Page1of19)DATASHEET1AUNIT1CHEMISTRYGRABSAMPLING(Page1of3)PAGE:26of741.Dateandtimeofdata:2.AskEmergencyCoordinator:A,AccidentTypeB.Iscoreoverheatingormelting(yes/no)1.IfthecoreISoverheatingormeltingPF=4.4,Ifnot,PF=1.0;EnterPF=C.PotentialDURATIONofrelease(ifunknown,use2):hours3.EntersampleassaydataofgrossNoblegasandDEQIodine-131pCI/CCconcentrationinthestep5tablebelowunderpCi/cc.4.Chooseandcalculatetheapplicablepathway(s):A.ChecktheONfansandlinethrutheSCFMofthefansNOTrunning.B.C.Adduptheflowsinthespacesprovided.EntertotalpathwaySCFMintheSCFMcolumninstep5.Fan1-HVE-6A1-HVE-6B1-HVE-7A1-HVE-7B1-HVE-8A1-HVE-8B1-HVE-10A1-HVE-10B(Add)PlantVentTotal=PLANTVENTNontI4SCFMShieldBldg66006600H>Purge950950RCBExhaust5250052500RABExhaust9256392563Fan1-HVE-9A1-HVE-9BECCSAREA'%4SCFM3300033000FUELBUILDINGFanNon%4SCFM1-HVE-15NewFuel105631-HVE-16AFuelPool113851-HVE-16B113851-HVE-17HBVRoom6250(Add)FuelBldg.Total=
REVISIONNo.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:27of74ATTACHMENT2RELEASERATEDATA(Page2of19)DATASHEET1AUNIT1CHEMISTRYGRABSAMPLING(Page2of3)5.CalculateReleaseRatesbycompletingthetablebelow:pCI/ccxSCFMxfactor=Ci/secPathwayPlantVentFuelBldg.ECCS-AECCS-8TYPEpCI/CCNobleGasIodineNobleGasIodineNobleGasIodineNobleGasIodine%4SCFM33,00033,000factor4.72E-044.72E-044.72E-044.72E-04NobleGas,Ci/sec9>%&&~,'.855Iodine,Ci/sec%goymeye6.CalculatetheSiteReleaseRate,Ci/sec,bycompletingthetablebelow.A.TotaltheUnit1releaseratesdeterminedaboveB.IFUnit2isAFFECTED,enteritsreleaseratesC.AddAandBtoobtaintheSITERELEASERATESNobleGas,Ci/secIodine,CI/sec7.EntertheSITERELEASERATESintheselectedDOSECALCULATIONWORKSHEET:A.OnlineB,checkGrabSampleunderUnit1B.EntertheNOBLEGASRELEASERATEintoline8C.EntertheIODINERELEASERATEintoline1D.EntertheDURATION(if2affectedunits,uselongest)intoline6E.EnterthePF(ParticulateFactor)(if2affectedunits,uselargest)intoline11 REVISIONNO.:PROCEDURENo.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTATTACHMENT2'ELEASERATEDATA(Page3of19)DATASHEET1AUNIT1CHEMISTRYGRABSAMPLING(Page3of3)PAGE:28of748.Thisdatasheetiscompleted,followtheinstructionsontheDOSECALCULATIONWORKSHEET(Attachment3).ENDOFDATASHEET1A REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:29of74ATTACHMENT2RELEASERATEDATA(Page4of19)DATASHEET2AUNIT2CHEMISTRYGRABSAMPLING(Page1of3)1.Dateandtimeofdata:2.AskEmergencyCoordinator:A.AccidentTypeB.Iscoreoverheatingormelting(yes/no)1~IfthecoreISoverheatingormeltingPF=4.4,Ifnot,PF=1.0;EnterPF=C.PotentialDURATIONofrelease(ifunknown,use2):hoursEntersampleassaydataofgrossNoblegasandDEQIodine-131pCi/ccconcentrationinthestep5tablebelowunderljCI/cc.4.Chooseandcalculatetheapplicablepathway(s):A.ChecktheONfans.B.Adduptheflowsinthespacesprovided.C.EntertotalpathwaySCFMintheSCFMcolumninstep5.PLANTVENTFan2-HVE-6A2-HVE-6B2-HVE-7A2-HVE-7B2-HVE-8A2-HVE-8B2-HVE-10AShieldBldgH2PurgeRCBExhaustRABExhaust2-HVE-10B(Add)PlantVentTotal=Nong4SCFM66006600250025005250052500105625105625Fan2-HVE-9A2-HVE-9B'tl4SCFM3300033000FUELBUILDINGIfNOTDivertedtoPlantVent,UseStatedFlowFandonSCFM2-HVE-15NewFuel121252-HVE-16AFuelPool125002-HVE-16BFuelPool125002-HVE-17BldgHBV7500(Add)FuelBldg.Total=ECCSAREA REVISIONNo.:PROCEDURENo.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:30of74ATTACHMENT2RELEASERATEDATA(Page5of19)DATASHEET2AUNIT2CHEMISTRYGRABSAMPLING(Page2of3)5.CalculateReleaseRatesbycompletingthetablebelow:pCi/ccxSCFMxfactor=Ci/secPathwayTYPEpCi/CC%4SCFMfactorNobleGas,Ci/secIodine,Ci/secPlantVentFuelBldg.ECCS-AECCS-BNobleGasIodineNobleGasIodineNobleGasIodineNobleGasIodine33,00033,0004.72E-044.72E-044.72E-044.72E-04'-.'.>,'P~f%!~%MS~~~I'~~WFC%~R~A$6.CalculatetheSiteReleaseRate,Ci/sec,bycompletingthetablebelow.A.TotaltheUnit2releaseratesdeterminedaboveB.IFUnit1isAFFECTED,enteritsreleaseratesC.AddAandBtoobtaintheSITERELEASERATESNobleGas,Ci/secIodine,Ci/sec7.EntertheSITERELEASERATESintheselectedDOSECALCULATIONWORKSHEET:A.OnlineB,checkGrabSampleunderUnit2B.EntertheNOBLEGASRELEASERATEintoline8C.EntertheIODINERELEASERATEintoline1D.EntertheDURATION(if2affectedunits,uselongest)intoline6E.EnterthePF(ParticulateFactor)(if2affectedunits,uselargest)intoline11 REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTATTACHMENT2RELEASERATEDATA(Page6of19)DATASHEET2AUNIT2CHEMISTRYGRABSAMPLING(Page3of3)PAGE:31of748.Thisdatasheetiscompleted,followtheinstructionsontheDOSECALCULATIONWORKSHEET(Attachment3).ENDOFDATASHEET2A REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTATTACHMENT2RELEASERATEDATA(Page7of19)DATASHEET1BUNIT1EFFLUENTMONITORS(Page1of3)PAGE:32of74Dateandtimeofdata:2.AskEmergencyCoordinator:A.AccidentTypeB.Iscoreoverheatingormelting(yes/no)1.IfthecoreISoverheatingormeltingPF=4.4,Ifnot,PF=1.0;EnterPF=C.PotentialDURATIONofrelease(ifunknown,use2):hours3.4.DetermineNobleGas(NG)concentrationsandenterintodatacolumninstep6.Chooseandcalculatetheapplicablepathway(s):A.ChecktheONfans.B.C.Adduptheflowsinthespacesprovided.EntertotalpathwaySCFMintheSCFMcolumninstep6.FanPLANTVENT1-HVE-6A1-HVE-6B1-HVE-7A1-HVE-7B1-HVE-8A1-HVE-8B1-HVE-10A1-HVE-10BShieldBldgH2PurgeRCBExhaustRABExhaust(Add)PlantVentTotal=Nong4SCFM6600660095095052500525009256392563FanFUELBUILDINGdonFanECCSAREA1-HVE-9A1-HVE-9B1HVE-15NewFuel1-HVE-16AFuelPool1-HVE-16B1-HVE-17H8VRoom(Add)FuelBldg.Total=%4SCFM1056311385113856250'ti4SCFM3300033000 REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTATTACHMENT2RELEASERATEDATA(Page8of19)DATASHEET1BUNIT1EFFLUENTMONITORS(Page2of3)PAGE:33of745.SelectPathwaysIODINEFACTOR(IF)fortheaccidenttypebelowandenterunderIFColumninstep6.PATHWAYLOCASGTRMSLBWASTEGASTRFUELHANDLINGCASKDROPPlantVentECCSFuelBldg.Steamline0.010.01001.E-06001.E-031.00004.E-05000000.040001.306.CalculateReleaseRatesbycompletingthetablebelow:DATAxSCFMxfactor=N.G.Ci/secxIF=IodineCi/secPathwayPlantVentECCS-AECCS-BFuelBldg.SteamlineASteamlineBDATAuCi/ccuCi/ccuCi/ccuCi/ccmr/hrmr/hr$4SCFM33,00033,0001.01.0factorNobleGas,Ci/sec4.72E-044.72E-044.72E-044.72E-041.24E-021.24E-02IFIodineCi/sec7.CalculatetheSiteReleaseRate,Ci/sec,bycompletingthetablebelow.A.EntertheUnit1releaseratesdeterminedfromthisworksheetB.IFUnit2isAFFECTED,enteritsreleaseratesC.AddAandBtoobtaintheSITERELEASERATESNobleGas,Ci/secIodine,Ci/sec REVISIONNO.:PROCEDURENo.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:34of748.ATTACHMENT2RELEASERATEDATA(Page9of19)DATASHEET1BUNIT1EFFLUENTMONITORS(Page3of3)EntertheSITERELEASERATESintheselectedDOSECALCULATIONWORKSHEET:/A.OnlineB,checkEffluentMonitorunderUnit1B.EntertheNOBLEGASRELEASERATEintoline8C.EntertheIODINERELEASERATEintoline1D.EntertheDURATION(if2affectedunits,uselongest)intoline6E.EnterthePF(ParticulateFactor)(if2affectedunits,uselargest)intoline11.9.Thisdatasheetiscompleted,followtheinstructionsontheDOSECALCULATIONWORKSHEET(Attachment3).ENDOFDATASHEET1B REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTATTACHMENT2RELEASERATEDATA(Page10of19)DATASHEET2BUNIT2EFFLUENTMONITORS(Page1of3)PAGE:35of741.Dateandtimeofdata:2.AskEmergencyCoordinator:A.AccidentTypeB.Iscoreoverheatingormelting(yes/no)1.IfthecoreISoverheatingormeltingPF=4.4,Ifnot,PF=1.0;EnterPF=C.PotentialDURATIONofrelease(ifunknown,use2):hours3.DetermineNobleGas(NG)concentrationsandenterintodatacolumninstep6.4.Chooseandcalculatetheapplicablepathway(s):A.ChecktheONfans.B.C.Adduptheflowsinthespacesprovided.EntertotalpathwaySCFMintheSCFMcolumninstep6.PLANTVENTFan2-HVE-6AShieldBldg2-HVE-6B2-HVE-7AH>Purge2-HVE-7B2-HVE-8ARCBExhaust2-HVE-8B2-HVE-10ARABExhaust2-HVE-10B(Add)PlantVentTotal=Non%4SCFM66006600250025005250052500105625105625Fan2-HVE-9A2-HVE-9B114SCFM3300033000FUELBUILDINGIFNOTDIVERTEDFandon([4SCFM2HVE-15NewFuel121252-HVE-16AFuelPool125002-HVE-16B125002-HVE-17H8VRoom7500(Add)FuelBldg.Total=ECCSAREA
REVISIONNO.:PROCEDURENo.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTATTACHMENT2RELEASERATEDATA(Page11of19)DATASHEET2BUNIT2EFFLUENTMONITORS(Page2of3)PAGE:36of745.SelectPathwaysIODINEFACTOR(IF)fortheaccidenttypebelowandenterunderIFColumninstep6.PATHWAYPlantVentECCSFuelBldg.SteamlineLOCA0.010.0100SGTR1.E-06001.E-03MSLB1.0000WASTE,GASTR4.E-05000FUELHANDLING0.0400.040CASKDROP1.301.306.CalculateReleaseRatesbycompletingthetablebelow:DATAxSCFMxfactor=N.G.Ci/secxIF=IodineCi/secPathwayPlantVentECCS-AECCS-BFuelBldg.SteamlineASteamline8DATAuCi/ccuCi/ccUCi/ccUCi/ccmr/hrmr/hrg4SCFM33,00033,0001.01.0factor4.72E-044.72E-044.72E-044.72E-041.24E-021.24E-02NobleGas,Ci/secIFiodineCi/sec7.CalculatetheSiteReleaseRate,Ci/sec,bycompletingthetablebelow.NobleGas,Ci/secIodine,Ci/secA.EntertheUnit2releaseratesdeterminedfromthisworksheetB.IFUnit1isAFFECTED,enteritsreleaseratesC.AddAandBtoobtaintheSITERELEASERATES REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTATTACHMENT2RELEASERATEDATA(Page12of19)DATASHEET2BUNIT2EFFLUENTMONITORSPAGE:37of74(Page3of3)EntertheSITERELEASERATESintheselectedDOSECALCULATIONWORKSHEET:A.OnlineB,checkEffluentMonitorunderUnit2.B.EntertheNOBLEGASRELEASERATEintoline8.C.EntertheIODINERELEASERATEintoline1.D.EntertheDURATION(if2affectedunits,uselongest)intoline6.E.EnterthePF(ParticulateFactor)(if2affectedunits,uselargest)intoline11.9.Thisdatasheetiscompleted,followtheinstructionsontheDOSECALCULATIONWORKSHEET(Attachment3).ENDOFDATASHEET2B REVISIONNO.:PROCEDURENo.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:38of74ATTACHMENT2RELEASERATEDATA(Page13of19)DATASHEET3CONTAINMENTHl-RANGERADIATIONMONITORS(ApplicabletoUnit1andUnit2)(Page1of3)NOTEIfbothunitsareusingthismethod,thencompleteoneworksheetforeachunit.1.Dateandtimeofdata:2.AskEmergencyCoordinator:A.AccidentTypeB.Iscoreoverheatingormelting(yes/no)1~IfthecoreISoverheatingormeltingPF=4.4,Ifnot,PF=1.0;EnterPF=C.PotentialDURATIONofrelease(ifunknown,use2):hours3.ObtainhighestCHRRMreadingandtimesincetrip:A.HighestCHRRMreading:R/hr,B.HourssinceReactorTrip:hours;C.CopytheCHRRMR/hrtostep6and8.4.Findinthetablebelowandenterintostep6and8,theCoreFractionfactor(CF).HoursSinceReactorTri)Otos05)0.5to61.0)1.0to52.0CF5.00E-071.00E-061.67E-063.33E-06CFHoursSinceReactorTri6.25E-061.25E-052.22E-05)2.0tos4.0)4.0to58.0)8.0%88%&%5!'5NRKaÃP~%PN"Ilk@E+kkR~A4':
REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:39of745.ATTACHMENT2RELEASERATEDATA(Page14of19)DATASHEET3CONTAINMENTHl-RANGERADIATIONMONITORS(ApplicabletoUnit1andUnit2)(Page2of3)Findinthetablebelowandenterintostep6theNobleGasReductionFactor(NGRF).HoursSinceRxTrip>Oto51>1to53>2to53>3to64NGRF1.00.900.700.600.50HoursSinceRxTrip>4tos5>5to56>6tos7>7to58>8to59NGRF0.440.390.350.320.28HoursSinceRxTrip>9tos10>10to511>11to512>12to513>13to614NGRF0.260.230.210.190.18HoursSinceRxTrip>14to615>15to516>16to517>17tos18>18NGRF0.160.160.140.140.136.7.8.9.CalculatetheNOBLEGASRELEASERATE,N.G.Ci/sec:R/hrx(CF)x(NGRF)x40=N.G.Ci/eecIftheIodineRemovalSystemISinusethenIodineConversionValue(ICV)=0.6,ifNOTinusethenICV=1.6.CopytheselectedICVintostep8.CalculatetheIODINERELEASERATE,lod.Ci/sec:R/hrx(CF)x(ICV)=lod.Ci/secCalculatetheSiteReleaseRate,Ci/sec,bycompletingthetablebelow.A)EnterthereleaseratesdeterminedfromthisworksheetB)IFtheotherUnitisAFFECTED,enteritsreleaseratesC)AddAandBtoobtaintheSITERELEASERATESNobleGasIodine REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:40of74ATTACHMENT2RELEASERATEDATA(Page15of19)DATASHEET3CONTAINMENTHI-RANGERADIATIONMONITORS(ApplicabletoUnit1andUnit2)(Page3of3)10.EntertheSITERELEASERATESintheselectedDOSECALCULATIONWORKSHEET:A.OnlineB,checkCHRRMundertheUnit(s)usingtheCHRRMmethod.B.EntertheNOBLEGASRELEASERATEintoline8.C.EntertheIODINERELEASERATEintoline1.D.EntertheDURATION(if2affectedunits,uselongest)intoline6.E.EnterthePF(ParticulateFactor)(if2affectedunits,uselargest)intoline11.11.Thisdatasheetiscompleted,followtheinstructionsontheDOSECALCULATIONWORKSHEET(Attachment3).ENDOFDATASHEET3 REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:41of74ATTACHMENT2RELEASERATEDATA(Page16of19)DATASHEET4POSTLOCAMONITORS(ApplicabletoUnit1orUnit2)(Page1of2)NOTEifbothunitsareusingthismethod,thencompleteoneworksheetforeachunit.1.Dateandtimeofdata:2.AskEmergencyCoordinator:A.AccidentTypeB.Iscoreoverheatingormelting(yes/no)1.IfthecoreISoverheatingormeltingPF=4.4,Ifnot,PF=1.0;EnterPF=C.PotentialDURATIONofrelease(ifunknown,use2):hours3.FortheReactorUnit(s),usingthismethod,obtaintheHicihestPOSTLOCAreadingmR/hr4.FortheapplicableUnit(s),findthereleaseratesinthetablebelowandentertheminstep5A.PostLocaMonitorReading(mR/hr)<60NobleGasReleaseRate(Ci/sec)NegligibleInUseNegligibleNotinUseNegligibleIodineReleaseRate,(Ci/sec)withIodineRemovalSystem)60<100)100<1000)10002.010.040.00.030.140.600.10.41.6 REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTATTACHMENT2RELEASERATEDATA(Page17of19)DATASHEET4POSTLOCAMONITORS(ApplicabletoUnit1orUnit2)(Page2of2)PAGE:42of74A)Ifused,entertheAFFECTEDUnit'sreleaseratesdeterminedfromthisworksheetB)IFtheotherUnitisAFFECTEDenteritsreleaseratesC)AddAandBtoobtaintheSITERELEASERATESNobleGas5.CalculatetheSiteReleaseRate,Ci/sec,bycompletingthetablebelow.Iodine6.EntertheSITERELEASERATESintheselectedDOSECALCULATIONWORKSHEET:A.OnlineB,checkPostLOCAundertheUnit(s)usingthePostLOCAmethod.B.EntertheNOBLEGASRELEASERATEintoline8.C.EntertheIODINERELEASERATEintoline1.D.EntertheDURATION(if2affectedunits,uselongest)intoline6.E.EnterthePF(ParticulateFactor)(if2affectedunits,uselargest)intoline11.7.Thisdatasheetiscompleted,followtheinstructionsontheDOSECALCULATIONWORKSHEET(Attachment3).ENDOFDATASHEET4 REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:43of74ATTACHMENT2RELEASERATEDATA(Page18of19)DATASHEET5DEFAULT(ApplicabletoUnit1orUnit2)(Page1of2)CAUTIONUsethismethodonlifthereisnodatatouseinothermethods.Dateandtimeofdata:2.AskEmergencyCoordinator:A.AccidentTypeB.Iscoreoverheatingormelting(yes/no)1.IfthecoreISoverheatingormeltingPF=4.4,Ifnot,PF=1.0;EnterPF=C.PotentialDURATIONofrelease(ifunknown,useDefaultDurationfromthetablebelow):hours3.FortheaffectedUnit(s)andtheaccidenttype,selectandcircletheNobleGasandIodineReleaseRatesinthetablebelow.AccidentTypeDefaultDurationIodineNobleGasReleaseRates,Ci/secLOCAWITHOUTIodineRemovalSysteminuseLOCAWITHIodineRemovalSysteminuseSteamGeneratorTubeRuptureMainSteamLineBreakFuelHandlingCaskDropWasteGasDecayTankRupture2hours2hours0.5hours0.5hours0.5hours0.5hours0.5hours37372.00.042.02.01.60.64.0E-050.014.0E-030.032.0E-06 REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:44of74ATTACHMENT2RELEASERATEDATA(Page19of19)DATASHEET5DEFAULT(ApplicabletoUnit1orUnit2)(Page2of2)4.CalculatetheSiteReleaseRate,Ci/sec,bycompletingthetablebelow.A)EnterthereleaseratesdeterminedfromthisworksheetB)IFtheotherUnitisAFFECTEDenteritsreleaseratesC)AddAandBtoobtaintheSITERELEASERATESNobleGasIodine5.EntertheSITERELEASERATESintheselectedDOSECALCULATIONWORKSHEET:A.OnlineB,checkDefaultundertheUnit(s)usingthedefaultmethod.B.EntertheNOBLEGASRELEASERATEintoline8.C.EntertheIODINERELEASERATEintoline1.D.EntertheDURATION(if2affectedunits,uselongest)intoline6.E.EnterthePF(ParticulateFactor)(if2affectedunits,uselargest)intoline11.6.Thisdatasheetiscompleted,followtheinstructionsontheDOSECALCULATIONWORKSHEET(Attachment3).ENDOFDATASHEET5ENDOFATTACHMENT2 REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:45of74ATTACHMENT3DOSECALCULATIONWORKSHEET(Page1of10)DATASHEET1StabilitClass=ASeabreezelmact=YESA.MetSummary:WINDDIRECTION(from)checkmethodused:TowerAFFECTEDSECTORSNOAA/NWSDefaultB.ReleaseRateMethod:Unit1GrabSampleEffluentMonitorCHRRMPOSTLOCADefaultAttachment4/6Unit2Dateandtimeofdatafromreleaseratedetermination:Followtheinstructionstocalculatedoses@lineInstructionforTHYROIDDOSES(CDE)EntertheIODINERELEASERATE,Ci/secEntertheWINDSPEED,mphDivideline1byline21Mile2Miles5Miles10MilesSNFSNFiodineDoseFactors,Multiplyline3byline4toobtainTHYROIDDOSERATE(CDE),mrem/hrEnterDURATIONofrelease,hoursMultiplyline5byline6toobtainPROJECTEDTHYROIDDOSE(CDE),mrem2.3E+048.1E+032.3E+038.0E+02SNFSNFPARline1012InstructionsforTOTALDOSES(TEDE)EnterNOBLEGASRELEASERATE,Ci/secEnterWINDSPEEDfromline2,aboveDivideline8byline9EnterthePARTICULATEFACTORMultiplyline10byline111mile2miles5miles10milesSNF131415161718DoseFactorsMultiplyline12byline13Enter(Line5multipliedby0.04)Addline14and15toobtainTOTALDOSERATE(TEDE),mrem/hrEnterDURATIONfromline6,aboveMultiplyline16byline17toobtainTOTALDOSE(TEDE),mrem5.02.60.730.26SNFPAR19Forwardthisworksheet(oracopy)totheEmergencyCoordinator{RMifdoneinEOF)C.DoseCalculationscompleted;continuemonitoringreleasesandassessingdoses.ENDOFDATASHEET1 REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:46of74ATTACHMENT3DOSECALCULATIONWORKSHEET(Page2of10)DATASHEET2StabilitClass=ASeabreezelmact=NOA.MetSummary:WINDDIRECTION(from)AFFECTEDSECTORScheckmethodused:TowerNOAA/NWSDefaultB.ReleaseRateMethod:Unit1GrabSampleEffluentMonitorCHRRMPOSTLOCADefaultAttachment4/6Unit2Dateandtimeofdatafromreleaseratedetermination:Followtheinstructionstocalculatodoses@lineInstructionforTHYROIDDOSES(CDE)1EntertheIODINERELEASERATE,Ci/sec2EntertheWINDSPEED,mph3Divideline1byline21Mile2Miles5Miles10MilesSNFSNF4IodineDoseFactors,5Multiplyline3byline4toobtainTHYROIDDOSERATE(CDE),mrem/hr6EnterDURATIONofrelease,hours3.8E+031.8E+037.9E+024.0E+02SNFSNF7Multiplyline5byline6toobtainPROJECTEDTHYROIDDOSE(CDE),mremlineInstructionsforTOTALDOSES(TEDE)8EnterNOBLEGASRELEASERATE,Ci/sec9EnterWINDSPEEDfromline2,above10Divideline8bylino911EnterthePARTICULATEFACTOR1Mile2Miles5Miles10MilesPARSNF12Multiplyline10byline1113DoseFactors14Multiplyline12bylino1315Enter(Line5multipliedby0.04)16Addline14and15toobtainTOTALDOSERATE(TEDE),mrem/hr17EnterDURATIONfromline6,above18Multiplyline16byfino17toobtainTOTALDOSE(TEDE),mrem0.820.570.250.13SNFPAR19Forwardthisworksheot(oracopy)totheEmergencyCoordinator(RMifdoneinEOF)C.Dosecalculationscompleted;continuemonitoringreleasesandassessingdoses.ENDOFDATASHEET2 REVISIONNo.:PROCEDURENo.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:47of74ATTACHMENT3DOSECALCULATIONWORKSHEET(Page3of10)DATASHEET3StabilitClass=BSeabreezeImact=YESA.MetSummary:WINDDIRECTION(from)AFFECTEDSECTORScheckmethodused:TowerNOAA/NWSDefaultB.ReleaseRateMethod:Unit1GrabSampleEffluentMonitorCHRRMPOSTLOCADefaultAttachment4/6Unit2Dateandtimeofdatafromreleaseratedetermination:FollowtheinstructionstocalculatedosesIlineInstructionforTHYROIDDOSES(CDE)1EntertheIODINERELEASERATE,Ci/sec2EntertheWINDSPEED,mph3Divideline1bylino21Mile2Miles5Miles10MilesSNFSNF4iodineDoseFactors,5Multiplyline3byline4toobtainTHYROIDDOSERATE(CDE),mrem/hr6EnterDURATIONofrelease,hours7Multiplyline5byline6toobtainPROJECTEDTHYROIDDOSE(CDE),mrem3.0E+041.1E+043.0E+031.1E+03SNFSNFPARlineInstructionsforTOTALDOSES(TEDE)8EnterNOBLEGASRELEASERATE,Ci/sec9EnterWINDSPEEDfromline2,above10Divideline8byline91Mile2Miles5Miles10MilesSNF11EnterthePARTICULATEFACTOR12Multiplyline10byline1113DoseFactors14Multiplyline12byline1315Enter(Line5multipliedby0.04)16Addline14and15toobtainTOTALDOSERATE(TEDE),mrem/hr17EnterDURATIONfromline6,above18Multiplyline16byline17toobtainTOTALDOSE(TEDE),mrem9.63.40.970.36SNFPAR19Forwardthisworksheet(oracopy)totheEmergencyCoordinator(RMifdoneinEOF)C.Dosecalculationscompleted;continuemonitoringreleasesandassessingdoses.ENDOFDATASHEET3 REVISIONNo.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:48of74ATTACHMENT3DOSECALCULATIONWORKSHEET(Page4of10)DATASHEET4StabilitClass=8Seabreezelmact=NOA.MetSummary:WINDDIRECTION(from)AFFECTEDSECTORScheckmethodused:TowerNOAA/NWSDefaultB.Relea'seRateMethod:Unit1GrabSampleEffluentMonitorCHRRMPOSTLOCADefaultAttachment4/6Unit2Dateandtimeofdatafromreleaseratedetermination:FollowtheInstructionstocalculatedosesIlineInstructionforTHYROIDDOSES(CDE)1EntertheIODINERELEASERATE,Ci/sec2EntertheWINDSPEED,mph1Mile2Miles5Miles10MilesSNFSNF3Divideline1byline24iodineDoseFactors,5Multiplyline3byline4toobtainTHYROIDDOSERATE(CDE),mrem/hr6EnterDURATIONofrelease,hours7Multiplyline5byline6toobtainPROJECTEDTHYROIDDOSE(CDE),mrem2.3E+046.0E+031.1E+035.7E+02SNFSNFlineInstructionsforTOTALDOSES(TEDE)8EnterNOBLEGASRELEASERATE,Ci/sec9EnterWINDSPEEDfromline2,above10Divideline8byline911EnterthePARTICULATEFACTOR12Multiplyline10byline111Mile2Miles5Miles10MilesSNF13DoseFactors14Multiplyline12byline1315Enter(Line5multipliedby0.04)16Addline14and15toobtalnTOTALDOSERATE(TEDE),mrem/hr17EnterDURATIONfromline6,above18Multiplyline16byline17toobtainTOTALDOSE(TEDE),mrem7.41.90.360.18SNFPAR19Forwardthisworksheet(oracopy)totheEmergencyCoordinator(RMifdoneInEOF)C.Dosecalculationscompleted;continuemonitoringreleasesandassessingdoses.ENDOFDATASHEET4 REVISIONNO.:PROCEDURENo.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:49of74ATTACHMENT3DOSECALCULATIONWORKSHEET(Page5of10)DATASHEET5StabilitClass=CSeabreezeImact=YESMetSummary:WINDDIRECTION(from)AFFECTEDSECTORScheckmethodused:TowerNOAA/NWSDefaultB.ReleaseRateMethod:Unit1GrabSampleEffluentMonitorCHRRMPOSTLOCADefaultAttachment4/6Unit2Dateandtimeofdatafromreleaseratedetermination:Followthoinstructionstocalculatodoses@lineInstructionforTHYROIDDOSES(CDE)1EntortheIODINERELEASERATE,Ci/sec1Milo2Miles5Miles10MilesSNF~2EntertheWINDSPEED,mph3Divideline1byline24IodineDoseFactors,5Multiplyline3byline4toobtainTHYROIDDOSERATE(CDE),mrem/hr6EnterDURATIONofrelease,hours7Multiplyline5byline6toobtainPROJECTEDTHYROIDDOSE(CDE),mrem6.0E+041.7E+043.9E+031.5E+03SNFSNFSNFlineInstructionsforTOTALDOSES(TEDE)8EnterNOBLEGASRELEASERATE,Ci/sec9EnterWINDSPEEDfromline2,above10Dividolino8bylino91Mile2Miles5Miles10MilesSNF11EnterthoPARTICULATEFACTOR12Multiplyline10byline1113DoseFactors14Multiplyline12byline1315Enter(une5multipliedby0.04)16Addlino14and15toobtainTOTALDOSERATE(TEDE),mrem/hr17EnterDURATIONfromline6,above18Multiplyline16byline17toobtainTOTALDOSE(TEDE),mrem19.05.31.20.48SNFPAR19Forwardthisworksheet(oracopy)tothoEmergencyCoordinator(RMifdoneinEOF)C.Dosecalculationscompleted;continuemonitoringreleasesandassessingdoses.ENDOFDATASHEET5 REVISIONNo.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:50of74ATTACHMENT3DOSECALCULATIONWORKSHEET(Page6of10)DATASHEET6StabilitClass=CSeabreezelmact=NOA.MetSummary:WINDDIRECTION(from)AFFECTEDSECTORScheckmethodused:TowerNOAA/NWSDefaultB.ReleaseRateMethod:Unit1GrabSampleEffluentMonitorCHRRMPOSTLOCADefaultAttachment4/6Unit2Dateandtimeofdatafromreleaseratedetermination:Followthoinstructionstocalculatodoses@lineInstructionforTHYROIDDOSES(CDE)1EntertheIODINERELEASERATE,Ci/sec2EntertheWINDSPEED,mph3Divideline1byline21Mile2Miles5Miles10MilesSNFSNF4iodineDoseFactors,5Multiplyline3byline4toobtainTHYROIDDOSERATE(CDE),mrem/hr6EnterDURATIONofrelease,hours7Multiplyline5byline6toobtainPROJECTEDTHYROIDDOSE(CDE),mrem6.0E+041.7E+043.3E+039.5E+02SNFSNFPARlineInstructionsforTOTALDOSES(TEDE)8EnterNOBLEGASRELEASERATE,Ci/sec9EnterWINDSPEEDfromlino2,above10Divideline8byline911EnterthePARTICULATEFACTOR12Multiplyline10byline111Mile2Milos5Miles10MilesSNF13DoseFactors14Multiplyline12byline1315Enter(Une5multipliedby0.04)16Addline14and15toobtainTOTALDOSERATE(TEDE),mrem/hr19.05.31.00.30SNF17EnterDURATIONfromline6,above18Multiplyline16byline17toobtainTOTALDOSE(TEDE),mrem19Forwardthisworksheet(oracopy)totheEmergencyCoordinator(RMifdoneinEOF)PARC.Dosecalculationscompleted;continuemonitoringreleasesandassessingdoses.ENDOFDATASHEET6 REVISIONNo.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:51of74ATTACHMENT3DOSECALCULATIONWORKSHEET(Page7of10)DATASHEET7StabilitClass=DSeabreezelmact=N/AA.MetSummary:WINDDIRECTION(from)AFFECTEDSECTORScheckmethodused:TowerNOAA/NWSDefaultB.ReleaseRateMethod:Unit1GrabSampleEffluentMonitorCHRRMPOSTLOCADefaultAttachment4/6Unit2Dateandtimeofdatafromreleaseratedetermination:FollowthoInstructionstocalculatedoseselineInstructionforTHYROIDDOSES(CDE)EntertheIODINERELEASERATE,Ci/secEntertheWINDSPEED,mph1Mile2Miles5Miles10MilesSNFSNFDivideline1byline2IodineDoseFactors,Multiplyline3byline4toobtainTHYROIDDOSERATE(CDE),mrem/hrEnterDURATIONofrelease,hoursMultiplyline5byline6toobtainPROJECTEDTHYROIDDOSE(CDE),mrem1.7E+056.0E+041.7E+045.7E+03SNFSNFPARline10InstructionsforTOTALDOSES(TEDE)EnterNOBLEGASRELEASERATE,Ci/secEnterWINDSPEEDfromline2,aboveDivideline8byline9EnterthePARTICULATEFACTOR1Mile2Miles5Miles10MilesSNF12131415161718Multiplyline10byline11DoseFactorsMultiplyline12byline13Enter(Line5multipliedby0.04)Addline14and15toobtainTOTALDOSERATE(TEDE),mrem/hrEnterDURATIONfromline6,aboveMultiplyline16byline17toobtainTOTALDOSE(TEDE),mrem53.019.05.31.8SNFPAR19Forwardthisworksheet(oracopy)totheEmergencyCoordinator(RMifdoneinEOF)C.Dosecalculationscompleted;continuemonitoringreleasesandassessingdoses.ENDOFDATASHEET7 REVISIONNo.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:52Of74ATTACHMENT3DOSECALCULATIONWORKSHEET(Page8of10)DATASHEET8StabilitClass=ESeabreezeImact=N/AA.MetSummary:WINDDIRECTION(from)AFFECTEDSECTORScheckmethodused:TowerNOAA/NWSDefaultB.ReleaseRateMethod:Unit1GrabSampleEffluentMonitorCHRRMPOSTLOCADefaultAttachment4/6Unit2Dateandtimeofdatafromreleaseratedetermination:Followtheinstructionstocalculatedoses@lineInstructionforTHYROIDDOSES(CDE)EntertheIODINERELEASERATE,Ci/secEntertheWINDSPEED,mphDivideline1byline21Mile2Miles5Miles10MilesSNFSNFIodineDoseFactors,Multiplyline3byline4toobtainTHYROIDDOSERATE(CDE),mrem/hrEnterDURATIONofrelease,hoursMultiplyline5byline6toobtainPROJECTEDTHYROIDDOSE(CDE),mrem3.0E+051.2E+053.8E+041.4E+04SNFSNFPARline10InstructionsforTOTALDOSES(TEDE)EnterNOBLEGASRELEASERATE,Ci/secEnterWINDSPEEDfromline2,aboveDivideline8byline91Mile2Miles5Miles10MilesSNF12131415161718EnterthePARTICULATEFACTORMultiplyline10byline11DoseFactorsMultiplyline12byline13Enter(Line5multipliedby0.04)Addline14and15toobtainTOTALDOSERATE(TEDE),mrem/hrEnterDURATIONfromline6,aboveMultiplyline16byline17toobtainTOTALDOSE(TEDE),mrem94.039.012.04.5SNFPAR19Forwardthisworksheet(oracopy)totheEmergencyCoordinator(RMifdoneinEOF)C.Dosecalculationscompleted;continuemonitoringreleasesandassessingdoses.ENDOFDATASHEET8 REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:53Of74ATTACHMENT3DOSECALCULATIONWORKSHEET(Page9of10)DATASHEET9StabilitClass=FSeabreezelmact=N/AA.MetSummary:WINDDIRECTION(from)AFFECTEDSECTORScheckmethodused:TowerNOAA/NWSDefaultB.ReleaseRateMethod:Unit1GrabSampleEffluentMonitorCHRRMPOSTLOCADefaultAttachment4/6Unit2Dateandtimeofdatafromreleaseratedetermination:FollowtheinstructionstocalculatedosesIlineInstructionforTHYROIDDOSES(CDE)EntertheIODINERELEASERATE,Ci/secEntertheWINDSPEED,mphDivideline1byline21Mile2Miles5Miles10MilesSNFSNFIodineDoseFactors,Multiplyline3byline4toobtainTHYROIDDOSERATE(CDE),mrem/hrEnterDURATIONofrelease,hoursMultiplyline5byline6toobtainPROJECTEDTHYROIDDOSE(CDE),mrem5.3E+05'.5E+057.9E+043.5E+04SNFSNFline1012InstructionsforTOTALDOSES(TEDE)EnterNOBLEGASRELEASERATE,Ci/secEnterWINDSPEEDfromline2,aboveDivideline8byline9EnterthePARTICULATEFACTORMultiplyline10byline111Mile2Miles5Miles10MilesSNF131415161718DoseFactorsMultiplyline12byline13Enter(Line5multipliedby0.04)Addline14and15toobtainTOTALDOSERATE(TEDE),mrem/hrEnterDURATIONfromline6,aboveMultiplyline16byline17toobtainTOTALDOSE(TEDE),mrem1.7E+027.8E+012.5E+011.1E+01SNFPAR19Forwardthisworksheet(oracopy)totheEmergencyCoordinator(RMifdoneinEOF)C.Dosecalculationscompleted;continuemonitoringreleasesandassessingdoses.ENDOFDATASHEET9 REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:54of74ATTACHMENT3DOSECALCULATIONWORKSHEET(Page10of10)DATASHEET10StabilitClass=GSeabreezeImact=N/AA.MetSummary:WINDDIRECTION(from)AFFECTEDSECTORScheckmethodused:TowerNOAA/NWSDefaultB.ReleaseRateMethod:Unit1GrabSampleEffluentMonitorCHRRMPOSTLOCADefaultAttachment4/6Unit2Dateandtimeofdatafromreleaseratedetermination:FollowtheInstructionstocalculatedoses@lineInstructionforTHYROIDDOSES(CDE)1EntertheIODINERELEASERATE,Ci/sec2EntertheWINDSPEED,mph1Mile2Miles5Miles10MilesSNFSNF3Divideline1byline24IodineDoseFactors,5Multiplyline3byline4toobtainTHYROIDDOSERATE(CDE),mrern/hr6EnterDURATIONofrelease,hours7Multiplyline5byline6toobtainPROJECTEDTHYROIDDOSE(CDE),mrem9.1E+054.7E+051.8E+057.9E+04SNFSNFlineInstructionsforTOTALDOSES(TEDE)8EnterNOBLEGASRELEASERATE,Ci/sec9EnterWINDSPEEDfromline2,above10Divideline8byline911EnterthePARTICULATEFACTOR12Multiplyline10byline111Mile2Miles5Miles10MilesSNF13DoseFactors14Multiplyline12byline1315Enter(Line5multipliedby0.04)16Addline14and15toobtainTOTALDOSERATE(TEDE),mrem/hr17EnterDURATIONfromline6,above18Multiplyline16byline17toobtainTOTALDOSE(TEDE),mrem2.9E+021.5E+025.7E+012.5E+01SNF19Forwardthisworksheet(oracopy)totheEmergencyCoordinator(RMifdoneInEOF)C.Dosecalculationscompleted;continuemonitoringreleasesandassessingdoses.ENDOFDATASHEET10ENDOFATTACHMENT3 REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:55of74ATTACHMENT4TSC/EOFDOSEASSESSMENTGUIDANCEFORRESPONDINGTOANUNMONITOREDCONTAINMENTBURP(Page1of8)1.PurposeThisattachmentprovidesmethodsforTSCand/orEOFDoseAssessmentpersonneltodefinereleaseratesfromacontainmentburpandincludesNRCsRTM-91methodsforestimatingdoseratesbasedonplant/reactorconditions.2.DiscussionA.AcontainmentburpisanysuspectedreleasefromthecontainmentthatmaybeindicatedbyarapiddecreaseofthecontainmentpressureorrapiddecreaseintheContainmentHighRangeRadiationMonitorthatisdetermined,byoperationsorengineering,notduetochangesinequipmentoperation(e.g.,additionalcontainmentspray,additionalcontainmentcoolers,etc.).B.Itmustberememberedandunderstoodthatthemethodologyprovidedinthisappendixincludesconservativeassumptionsandisintendedtoprovidethemeanstoestimateanupperboundtotherelease,notanexactreleaserate.3.ContentsSection1:ProvidesguidanceinestimatingreleaseratesduringaLOCAresultingfromrapidcontainmentdepressurizations;thatis,anunmonitoredburprelease.Theguidanceisfurthersub-dividedintothreecases:Case1-RapiddecreaseinCHRRMreadingduringburpCase2-NochangeinCHRRMreadingduringburpCase3-IncreaseinCHRRMreadingduringburpSection2:Providesguidanceinestimatingdosesbasedonplant/reactorconditionsfollowingthemethodologyinNRCRTM-91.
t4J'FP REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:56of74ATTACHMENT4TSC/EOFDOSEASSESSMENTGUIDANCEFORRESPONDINGTOANUNMONITOREDCONTAINMENTBURP(Page2of8)4.BasisSection1:AssumesCHRRMisrespondingonlytoNobleGasesAssumesCuriesin.(fromcore)<<Curieslost2E+06R/hr=100%CoreInventoryofNobleGas(1'FT=oCFfromEPIP-09)6.43E+08CuriesofNobleGasis100%CoreInventory(PSL2UFSAR)322=6.43E+08Curies~2E+06R/hrSection2:NRC'sResponseTechnicalManualRTM-91Vol.1,Rev.1,pg.C-2.5.PercentMassLossA.UseAttachment5,EstimateofContainment"%MassLoss",todeterminethevaluesrequiredinthefollowingcalculations.
REVISIONNo.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:57of74ATTACHMENT4TSC/EOFDOSEASSESSMENTGUIDANCEFORRESPONDINGTOANUNMONITOREDCONTAINMENTBURP(Page3of8)DATASHEET1(ApplicabletoUnit1orUnit2)(Page1of5)Case1:RaidDecreaseinCHRRMReadinNOTE1.ACHRRMdropofabout3percentperhourmaybeduetoradiologicaldecay.2.TheCHRRMmaydropbyasmuchas10percentveryquicklyifcontainmentsraisactuatedduetoIodinewashout.METHOD:Dateandtimeofdata:2.CalculateDelta-CHRRM:StartCHRRM3.CalculateDuration:-EndCHRRMDelta-CHRRM,R/hrA.ClockTimeEnd-ClockTimeStartDelta-ClockB.ConvertDelta-ClocktoDelta-Seconds:4.EstimateCuriesLost:DeltaCHRRMx322CiN.G.perR/hr=5.EstimateNobleGasReleaseRate(lossrate):b,secNobleGasCuriesLost6.NobleGasCurieslost+EstimatetheIodineReleaseRate:6sec=NobleGasCi/secN.G.Ci/secx0.01(iodineFactor)=iodineCi/secUtilizethecurrentmeteorologicalconditionsandappropriateDoseCalculationWorksheets(circle4nexttoAttachmentasmethod)orenterasDirectifusingthecomputer,toestimateOffsiteDoses.
REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:58of74ATTACHMENT4TSC/EOFDOSEASSESSMENTGUIDANCEFORRESPONDINGTOANUNMONITOREDCONTAINMENTBURP(Page4of8)DATASHEET1(ApplicabletoUnit1orUnit2)(Page2of5)Case2:ConstantCHRRMReadinNOTEEngineeringmayberequestedtoevaluatethepercentmasslostinthebur.METHOD:1.Dateandtimeofdata:2.EstimateNobleGasCuriesinthecontainment:CHRRMR/hrx322CiN.G.perR/hr=3.CalculateDuration:NobleGasCuriesincanA.ClockTimeEnd-ClockTimeStartDelta-ClockB.ConvertDelta-ClocktoDelta-Seconds:b,sec4.EstimateCuriesLost:A.Determine"%MassLoss"B.N.G.Curiesincanlost%masslost~100=NobleGasCuries5.EstimateNobleGasReleaseRate(lossrate):NobleGasCurieslostb,sec=NobleGasCi/sec REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:59of74ATTACHMENT4TSC/EOFDOSEASSESSMENTGUIDANCEFORRESPONDINGTOANUNMONITOREDCONTAINMENTBURP(Page5of8)DATASHEET1(ApplicabletoUnit1orUnit2)(Page3of5)Case2:ConstantCHRRMReadin6.EstimatetheIodineReleaseRate:N.G.Ci/secx0.01(IodineFactor)=IodineCi/sec7.UtilizethecurrentmeteorologicalconditionsandappropriateDoseCalculationWorksheets(circle4nexttoAttachmentasmethod)orenterasDirectifusingthecomputer,toestimateOffsiteDoses.
REVISIONNoPROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONStST.LUCIEPLANTPAGE:60of74ATTACHMENT4TSC/EOFDOSEASSESSMENTGUIDANCEFORRESPONDINGTOANUNMONITOREDCONTAINMENTBURP(Page6of8)Section1(ApplicabletoUnit1orUnit2)(Page4of5)Case3:IncreasinCHRRMReadinNOTEEngineeringmayberequestedtoevaluatethepercentmasslostinthebur.METHOD:1.Dateandtimeofdata:2.CalculateaverageCHRRMreading(StartCHRRM+EndCHRRM)~2=EstimateNobleGasCuriesinthecontainment:Avg.CHRRMR/hrx322CiN.G.perR/hr=AvgCHRRM,R/hrNobleGasCuriesincanCalculateDuration:A.ClockTimeEnd-ClockTimeStartDelta-ClockB.ConvertDelta-ClocktoDelta-Seconds:b,sec5.EstimateCuriesLost:A.Determine"%MassLoss"B.N.G.Curiesincanx%masslost~100=NobleGasCurieslost REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:61of746.ATTACHMENT4TSC/EOFDOSEASSESSMENTGUIDANCEFORRESPONDINGTOANUNMONITOREDCONTAINMENTBURP(Page7of8)DATASHEET1(ApplicabletoUnit1orUnit2)(Page5of5)Case3:IncreasinCHRRMReadinEstimateNobleGasReleaseRate(lossrate):NobleGasCurieslost-:Dsec=NobleGasCi/sec7.EstimatetheIodineReleaseRate:N.G.Ci/secx0.01(IodineFactor)=IodineCi/sec8.UtilizethecurrentmeteorologicalconditionsandappropriateDoseCalculationWorksheets(circle4nexttoAttachmentasmethod)orenterasDirectifusingthecomputer,toestimateOffsiteDoses.ENDOFDATASHEET1 REVISIONNo.:PROCEDURENOEPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:62of74ATTACHMENT4TSC/EOFDOSEASSESSMENTGUIDANCEFORRESPONDINGTOANUNMONITOREDCONTAINMENTBURP(Page8of8)TABLE1(ApplicabletoUnit1orUnit2)UsethismethodIFthereisnotradiologicaldata(e.g.,CHRRM,containmentgrabsample,etc.)ANDtheaccidenthasprogressedpastgapfailureANDthecontainmenthasundergonecatastrophicfailure(e.g.,knowthereshouldbepressureandthereisnone).NOTEThefollowingmethodprovidesDOSES,notreleaserates.DosesbasedonstabilitclassDandfourm..h.windseed.REACTORACCIDENTCONSEQUENCEOVERVIEWContainmentLeakaeCoreConditionContainmentStatusMitigatingSystemStatus'"WBTHYAcuteDose(rem)1hourReleaseI1mile'MELTReleaseFromCore45QQ'FGapReleaseFromCore1500'FEarlytotalFailure((1hr)Latetotalfailure(2-12hr)MajorLeakage(100%/day)DesignleakageEarlytotalFailure((1hr)Latetotalfailure(2-12hr)MajorLeakage(100%/day)DesignLeakageNoMitigationMitigatedN/AN/AN/ANoMitigationMitigatedN/AN/AN/A1000+2502501010501010'010+101O4101O410101010Notes:(A)Sprays,filters(B)1hourcloudimmersionandinhalationplus3hoursofgroundshineENDOFTABLE1ENDOFATTACHMENT4 REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:63of741.PurposeATTACHMENT5'tt2ESTIMATEOFCONTAINMENT"%MASSLOSS"(Page1of2)(ApplicabletoUnit1orUnit2)Thepurposeofthiscalculationistoprovideamethodtoestimatecontainment%massreleasetotheenvironmentduringapost-LOCAcontainmentdepressurizationtransient(containment"burp").2.DiscussionA.ThescopeofthiscalculationisSt.LucieUnits1and2.B.Thedoseassessmentgroupcanusethecontainmentmassreleasedatatoestimatetheradiationreleasetotheenvironment(usingAttachment4,TSC/EOFDoseAssessmentGuidanceforRespondingtoanUnmonitoredContainmentBurp)providedthecontainmentradiologicalconditionsareknown.3.C.Thecontainmentde-pressurizationeventshouldbelarge(greaterthan5.0psichange),overashortperiodoftimesincethemethodologydoesnotaccuratelycredittheeffectofcontainmentheatremovalsystems.Acquirethefollowingdata:NOTEThe"timespan"fordataobservationshouldbethesameasusedforthecalculationonAttachment4,Case2or3.A.ContainmentPressurejustbeforeblowdowntransient:B.ContainmentTemperaturejustbeforeblowdowntransient:psig(Pstart)degF(Tstart}C.ContainmentPressurejustafterblowdowntransient:psig(Pend)D.ContainmentTemperaturejustafterblowdowntransient:degFPend)
REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTATTACHMENT5ESTIMATEOFCONTAINMENT"%MASSLOSS"(Page2of2)(ApplicabletoUnit1orUnit2)PAGE:64of744.EstimateInitialContainmentAtmosphereDensity:144x(14.7+.....Pstart)InitialDensity53.3x(460+.....Tstart)5.EstimateEndContainmentAtmosphereDensity:144x(14.7+.....Pend)EndDensity53.3x(460+.....Tend)6.Estimate%MassLost:1minus.........EndDensityxl00=%masslost~.........InitialDensityENDOFATTACHMENT5 REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTATTACHMENT6FIELDTEAMMEASUREMENTSASSESSMENT(Page1of3)PAGE:65of74tt3ThisattachmentprovidesmethodstoestimateareleaseratefromFieldMonitoringTeamsurveymetermeasurementsandprovidesguidanceoncomparingfieldmeasurementstodoseprojections.NOTESurveymeterGamma(closedwindow)resultsmustbefromplumecenterline;thatis,themaximumvaluefromalateraltransverseofthelume.1~DATE:ITIME:'nit:~y2.Ifthesurveymetermeasurementwasat1milevalue,ThengotoStep4.3.Estimatethe1milevalue:Estimated1milevalue=Surveymeterresultsx(downwinddistance,miles)WheretheexponentZ=2forStabilityClassA,B1.5forStabilityClassC,D1.0forStabilityClassE,F,G(Z)mr/hrx(miles)=meterresultsdownwinddistanceEstimated1milemr/hr4.Forthemetconditionsattimeofsampling,selecttheDoseCalculationWorksheet(DCW).A.UseWindSpeedinMilesPerHour,mphB.CopyfromLine13,the1mileDosefactorastheDFforuseinStep5.EstimateNobleGasReleaseRate:Estimated1milemr/hr~DFxWindSpeedmr/hr~(DF)xNobleGasCi/sec REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTATTACHMENT6FIELDTEAMMEASUREMENTSASSESSMENT(Page2of3)PAGE:66of746.EstimateIodineReleaseRate(IF=IodineFactor,seetheaffectedunits'ffluentMonitorWorksheet):7.N.G.Ci/secx(IF)=Iodine(131Deq)Ci/secUtilizethecurrentmeteorologicalconditionsandappropriateDoseCalculationWorksheets(circle6nexttoAttachmentasmethod),orenterreleaseratesasDirectifusingthecomputer,toestimateOffsiteDosesfromthisattachment.ComgrinFieldMeasurementsToDosePro'ectionsNOTE1."Reasonablecomparison"betweenFieldMeasurements&DoseCalculationsisifthetwoarewithinanorderofmagnitude.Toomanyassumptionsprecludebetterprecision.2.Asurveyteammeasurements'offcenterline'illyieldalowestimatedreleaserate.TheFieldMonitoringCoordinator(EOF)hasamethodforestimatincenterlinevaluesforthesesituations.SurveMeterDDEReadinsThecomputerizeddosecalculationprogramestimatesthe'surveymeterreading'DEandforthepre-designatedsamplinglocations(refertoFieldSurveyMapfordescriptionsofthelocations).ThisSurveyMeterEstimateissumofimmersioninplumeofNobleGas,andplumeshinefromiodine&particulates.Thenoblegassesarethemajorityoftheexposuresource.TheprogramadjustsforgapversuscoremixofnoblegassesinresponsetotheCoreDamageSituationquestion.ThemanualmethoddoesnotcalculateaDDEfromimmersioninnoblegas.ReferringtoaDoseCalculationWorksheetapropostothemetconditions,avaluecouldbeestimatedbymultiplyingthevaluecalculatedonline10bytheDoseFactorslistedonline13.TheseDoseFactorsarebasedonacoremixofnoblegasses,andincludetheX/Qfortheprevailingmeteorologicalconditions.
REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTATTACHMENT6FIELDTEAMMEASUREMENTSASSESSMENT(Page3of3)PAGE:67of74chidC0EThyroiddoseprojections,bothprocedure8computer,arebasedonareleaseof1-131DeqCi/sec.Thefieldteamsmeasurel-131intheplume;theirprocedurehasatimedependentfactortoaccountforthedosefromtheotheriodines.Thefactorstartsatabout1.4anddecaysto1(one)overabout24hours.Dividingprojectedthyroiddoserate,mr/hrby1.3E+9willestimatetheIodine131(Deq)concentrationuCi/cc.TimeofSamlev.TimeofReleaseTimeoffieldmeasurementminus(downwinddistance,miles/windspeed,m.p.h.)willyieldthe'time'fthereleaserateestimated.Thecomputerizedcalculationsuseatimewindow15or30minuteslong.SelectthelatestprintoutthathasaReleaseObservationTimebeforethetimeestimatedabove.EstimatinDoseRatesOrConcentrationsAtOtherDistances(e.g.,1,2,5,10miles)EstimatedValue@Distx=Measuredvaluetimes(DWD/Distx)'here:DWD=Measurementdownwinddistance,milesDistx=otherdistance,milesZ=exponentbasedonstabilityclass(refEPA-520Rev.6/79,page5.10.)ENDOFATTACHMENT6 REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:68of74ATTACHMENT7OFF-SITECALCULATIONS-CLASSACOMPUTERMETHOD(Page1of7)DiscussionThecomputer-basedClassAModeldosecalculationprogramutilizesinputsandprocessessimilartothemanualprocedure.However,therefinementsavailableinthecomputerbasedprocessallowforawiderrangeofinputinformationandmathematicalcomplexitythanavailableinthemanualmethod.Theseinstructionsprovidetheguidanceforusingthecomputerbasedprocesstoderivecalculatedoff-sitedosesinamannersimilartothatdiscussedforthemanualcalculation.Notallinputscreensavailableinthecomputerprogramareneededbythegeneraluserandare,thereforenotdiscussedintheseinstructions.Thesescreensmaybeutilizedbypersonnelfamiliarwiththeirintendeduse.ThecomputerizedClassAModelprovidestwo(2)typesofdosecalculations.The"ActualDoseCalculation"whichisaccomplishedinadvectionstepsoffifteen(15)orthirty(30)minutesandisacumulativedosedeterminationandthe"ForecastDoseCalculation"whichisaprojecteddosedeterminationbasedonagiventimeperiodsuchastwo(2)hours.Personnelhavingexpertiseindosecalculationmethodologymayutilizethatexpertiseincombinationwiththeadvancedmethodsavailablethroughthescreendrivenmenustomodifyandrefinethesebasiccalculations.NOTEIftheTechnicalSupportCenter(TSC)andEmergencyOperationsFacility(EOF)aremannedandoperational,doseassessmentpersonnelattheselocatiorIsshouldcoordinatetheireffortsinordertocalculatethemostaccurateavailableoff-sitedosero'ections.ComuterStartu1.Ensuretheuninterruptiblepowersupplytothecomputerisenergizedtopreventdatalossifapowerinterruptionoccurs.2.Ensurethatthefloppydiskdriveisempty.3.Turnonthedisplaymonitor,theprinterandthecomputer.
REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:69of74ATTACHMENT7OFF-SITECALCULATIONS-CLASSACOMPUTERMETHOD(Page2of7)4.Followingsystemstartup,checkthedateandtimeonthecomputer.NOTECorrectingthedateandtimeshouldbedonepriortousingastand-alonecomputer.WhenusingacomputerontheLAN,contactaLANadministratorifthedateand/ortimeneedtobechaned.A.Ifthedosecalculationprogramstarts,Thenthedateandtimeisshownintheupperleftofthemonitor.B.Correctthedateandtimeasnecessary(timeshouldmatchERDADS).Changingthedate/time.1.DepressFunctionKeyF5(toquittheClassAsoftware).2.Type"Y".3.Depressthe"ENTER"key.4.Atthesystemprompt,type"TIME"(or"DATE"asrequired).5.Depressthe"ENTER"key.6.Typecorrectdataanddepress"ENTER"key.C.Ifthedosecalculationprogramdoesnotstart,ThenthedateandtimeischeckedatthesystempromptusingSteps4-6above.5.Whenthecomputerdisplaysthesystemprompt,andhascorrectdate/time,type"FPL"anddepress"ENTER"keytoreturntoClassAsoftware.Pre-useQCCheckIftimeandmanpowerpermits,Thenperformapre-useverificationQCcheckfollowingtheinstructionsintheFPLClassAEmergencyOffsiteDoseGaleProgramUserGuide.2.Atthecompletionofthepre-useQCcheck,exittotheMainMenu,andproceedtostep3ofPerformingCalculations,below.
REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:70of74ATTACHMENT7OFF-SITECALCULATIONS-CLASSACOMPUTERMETHOD(Page3of7)NOTEIfeditingisrequired,edittheinformationinaccordancewiththedisplayedinstructions.PerforminCalculationsCAUTIONChanging"Advectiontimestep"afteracalculationstepcancausetheClassAmodeltoenerateerrors.3.Whentheplantsitemenuisdisplayed,ThendepresstheFunctionKey(i.e.,F1-Unit1orF2-Unit2)toselecttheaffectedSt.LuciePlantUnit.Whentheprogramasks,"Isthisanexercise[Y/N]?",Thenanswerappropriatelyanddepressthe"ENTER"key.WhentheMainMenuisdisplayed,ThenselecttheF1FunctionKeytostartcalculations.4.Whenpromptedbytheprogram,"Warning-Startcalculationswilldestroypreviousdosevalues.OK[Y/N]?",Thendepress"Y"andthe"ENTER"keytoreinitializethedatafiles.NOTE1.Thirtyminuteadvectionstepsarenormallyusedexceptforfuelhandlingaccidents,forwhichfifteenminutesadvectiontimestepsshouldbeused.2.Onceadvectiontimeisselecteditshouldnotbechangedwhilerunningtheroramtoreventeneratinerrors.5.SelectfromthescreenfunctionsdisplayedontheGeneralAccidentInformationWorksheettoeditthetypeofaccident,reactortriptime,releasestarttime,andadvectionstepintheformatshownonthescreenbydepressingthecorrespondingFunctionKeys,F1,F2,F3orF4respectively,Thendepress"ENTER"aftereachnewentry.
REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:71of74ATTACHMENT7OFF-SITECALCULATIONS-CLASSACOMPUTERMETHOD(Page4of7)6.Whenthecorrecttypeofaccident,reactortriptime,releasestarttime,andtheadvectiontimestephavebeenentered,ThendepresstheF5FunctionKeytoaccepttheinputs.7.WhentheInputMenuisdisplayed,ThendepresstheF1FunctionKeytobringuptheMeteorologicalDatamenu.8.WhentheMeteorologicalDataSummaryMenuisdisplayed,Selectthedatasheetcorrespondingtothesourceofthedata(i.e.,SiteTower(ERDADS,chartrecorder),Airport(NOAA,NWS),Default).9.EnterthemeteorologicaldatagatheredintheformatshownusingthedisplayedFunctionKeys,Thendepressthe"ENTER"keyaftereachnewentry.10.Whenallnecessarymeteorologicaldatahasbeenentered,ThendepresstheF5FunctionKeytoacceptthedataandgototheMeteorologicaldataSummaryMenu.11.Reviewtheenteredmeteorologicaldata,~OeresstheF5FunctionKeytoacceptthedataandThenreturntotheInputMenu.12.WhentheInputMenuisdisplayed,ThendepresstheF2FunctionKeytobringuptheSourceTermDatamenu.13.IftheaccidenttypeisaLOCAorSGTR,~ResondappropriatelytothequestionabouttheCoreDamageSituation.14.IftheaccidenttypeisaLOCA,~ResondappropriatelytothequestionabouttheIodineRemovalSystemStatus.15.WhentheSourceTermSummaryMenuisdisplayed,Selectthedatasheetcorrespondingtothesourceofthedata(i.e.,GrabSampling,EffluentMonitors,CHRRM,PostLOCAMonitors,Default).16.EnterthesourcetermdatagatheredintheformatshownusingthedisplayedFunctionKeys,Thendepressthe"ENTER"keyaftereachnewentry.
REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:72of7417.18.ATTACHMENT7OFF-SITECALCULATIONS-CLASSACOMPUTERMETHOD(Page5of7)Whentheinputofsourceterminformationhasbeencompleted,ThendepresstheappropriateFunctionKeytoacceptthedataandreturntotheInputMenu.Ifafinalcheckofdataaccuracyisneeded,ThendepresstheF3FunctionKeytoreviewasummaryofthemeteorologicalandsourcetermdata,~DeresstheF1FunctionKeytoprintortheF2FunctionKeytoexit.19.Ifthemeteorologicalorsourcetermdataneedtoberevised,Gotostep7orstep12above,respectively.20.~DeresstheF4FunctionKeyatthescreenprompt,"Proceedwithcalculations[Y/N]?",andansweruY",~Deressthe"ENTER"keytobegincalculations.NOTE"CRTDislas"mabeusedinsteadof"PrintReorts".21.22.WhentheOutputMenuisdisplayed,ThendepresstheF3FunctionKeytoselect"PrintReports".WhenthePrintedReportMenuisdisplayed,ThendepressthedisplayedFunctionKeystoselectthedesiredreports.CAUTIONEnsurethattheprinterandprintbufferareonlineandreadyforusepriortoproceedingwiththeprintingtask.Ifeitherdeviceisnotreadyforuse,thecornuterwillexitthedosecalculationroram.23.24.~Deressanykeytobeginprinting.WhentheOutputMenuisdisplayed,ThendepresstheF6FunctionKeytoselecttheRunModeMenu.25.WhentheRunModeMenuisdisplayed,ThendepresstheF1FunctionKeytoselecttheActualCalculationModeandperformthenextadvectionstep(cumulativedosecalculation)ordepresstheF2FunctionKeytoselecttheForecastCalculationMode.
REVISIONNO.:PROCEDURENo.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:73of74ATTACHMENT7OFF-SITECALCULATIONS-CLASSACOMPUTERMETHOD(Page6of7)NOTE1.Forecastperiodsaretypicallytwo(2)hours.2.Forecastdosesassumereleaseratesandmeteorologicalconditionsremainconstantduringtheforecastingperiodchosen.3.Considerthereasonablenessofassumingconstantmeteorologicalconditionsandreleaseratesforforecastingperiodsexceedingtwo(2)hours.26.Edittheforecastperiodasdesiredusingthedisplayedinstructions.27.Whentheforecastperiodhasbeenaccepted,theInputMenu:ForecastCalculationModewillbedisplayed,ThendepressthedisplayedFunctionKeystoreviewand/oredittheinputsasnecessary.28.Whenallinputsareacceptable,ThendepresstheF4FunctionKeytoperformcalculations,atthescreenprompt,"Proceedwithcalculations[Y/N]?",andanswer"Y",and~Deressthe"ENTER"keytobegincalculations.NOTE"CRTDislasmabeusedinsteadof"PrintReorts".29.WhentheOutputMenu-ForecastCalculationsmodeisdisplayed,ThendepresstheF3FunctionKeytoselect"PrintReports".30.WhenthePrintedReportMenuisdisplayed,ThendepressthedisplayedFunctionKeystoselectthedesiredreports.
REVISIONNO.:PROCEDURENO.:EPIP-09PROCEDURETITLE:OFF-SITEDOSECALCULATIONSST.LUCIEPLANTPAGE:74of74ATTACHMENT7OFF-SITECALCULATIONS-CLASSACOMPUTERMETHOD(Page7of7)CAUTIONTheprinterandrintbuffermustbeonlineandread!NOTE1.TheEmergencyCoordinatorshouldbeprovidedwithaprintoutofactualcalculateddoses,ProtectiveActionRecommendations(PARs),andasrequested,forecasteddoses.2.TheEmergencyCoordinatorshouldbeupdatedeverythirtyminutesdurineriodsofactualorotentialoff-siterelease.31.Whenthereportshavebeenprinted,ThenreturntotheRunModeMenutoupdateinformationandrepeatthedosecalculationprocessasneededduetoreleaserateormeteorologicalchanges.32.~DeresstheF1FunctionKeyfortheActualCalculationModeortheF2FunctionKeyfortheForecastCalculationModeortheF3FunctionKeytoreturntotheMainMenuandquit.33.ReviewtheSummaryofMetandSourceDatadisplaysforallsubsequentcalculationseveniftheinputsdonotchangesothattheycanbereviewedandaccepted.AlsoensurethattheNobleGasReductionFactorisresettoitspropervalue.ENDOFATTACHMENT7 Cr>l' 9b5.r'PLR~v'~if~El/'~<&dii/dlof.ST.LUCIEPLANTEMERGENCYPLANIMPLEMENTINGPROCEDURESAFETYRELATEDProcedureNo.EPIP-1Currentev.No.4ectiveDate:09/26/00Title:FF-SITERADIOLOGICALMOORINGResponsiblDepartment:EMERGENCYPREPAREDNESSRevisionSuaryRevision4-CorrctedsamplelocationdesignationonAtthment5,addeddoserateorconcentrationestimingcapability,madeadministrativeadeditorialchanges,andrevisedthedoseandsurveytaworksheet.(J.R.Walker,09/1/00)Revision3-Addedon-simonitoringpoints,madedministrativechanges,andincorporatednewattachmet.(J.R.Walker,09/21/9)Revision2-Improvedstatusoardupdatein'uctions,correctedprocedurenumbertoaddressQAcommentfromperiicreviewA'ppendixJ),andaddededitorialchanges.(J.R.Walker,03/18/99)P-8C3PSLPAOCEDUREPm}DVCTIONRevisionFRGReviewDate012/15/97RevisionFRGReviewDate09/21/00-ApprovedByJ.ScarolaPlantGeneralManagerApprovedByR.G.WestPlantGeneralManagerN/ADesignatedApproverN/ADesignatedApprover(MinorCorrection)ApprovalDe12/15/97ApprovalDate09/21/00SOPSDATEDOCTPROCEDUREOCNEPIP-10SCOPCOMPLETEDITM4 lIt~*f>>lII'I'l<tf' REVISIONNo.:PROCEDURENo.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGST.LUCIEPLANTTABLEOFCONTENTSPAGE:2of37SECTIONPAGE1.0PURPOSE
32.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTS............~...~.~....~~~~...'~...~.3.0RESPONSIBILITIES3.1TechnicalSupportCenterHealthPhysicsSupervisor3.2EOFHealthPhysicsManager....~~~.....~~'...3.3FieldMonitoringTeamCommunicator/Coordinator(FMTComm/Coord)...~~.....~....34FieldMonitoringTeamCoordinator(FMTCoord)...4.0DEFINITIONS......5.0'NSTRUCTIONS.~..~........5~~~~~~5~~~~~~~~68ATTACHMENTSATTACHMENT1(TSC)FMTCoord/CommChecklist............,...10ATTACHMENT2(EOF)FMTCoordChecklist....~~..~.~~..A%IACHMENT3,CommunicationsGuidelines.1417ATTACHMENT4FieldMonitoringGuidelinesATTACHMENT5PreselectedOn-siteMonitoringPoints..~~~~....ATTACHMENT6PreselectedOff-siteMonitoringPoints..........ATTACHMENT7FieldMonitoringTeamsSurveyResults202l2530ATTACHMENT7AFieldMonitoringTeamsSurveyResults-Instructions.31ATTACHMENT7BEstimateofThyroidDoseRate...~~...ATTACHMENT8DoseandSurveyDataWorksheetATTACHMENT8ADoseandSurveyDataWorksheet-InstructionsATTACHMENT9EstimatingDose,DoseRateorConcentrationAtOtherDistances~...~~...........~~~.~..~.~......33343537
REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGPAGE:3of37EPIP-101.0PURPOSEST.LUCIEPLANT1.1Discussion1.Thisprocedureprovidesinstructionsfortabulatingoff-sitemonitoringdataandcalculatingdosesoftheFieldMonitoringTeam(FMT)personnelbasedondataresultingfromoff-siteradiologicalmonitoring.2.FieldmonitoringactivitiesaredirectedbytheTechnicalSupportCenter(TSC)initiallyandlaterbytheEmergencyOperationsFacility(EOF),onceitgoesoperational~3.ThisprocedureistobeusedbytheFMTComm/CoordintheTSCandtheFMTCoordintheEOF.4.Fieldmonitoringactivitiesaregovernedbytwoprocedures:A.ThisprocedureprovidesinstructionsfordirectionandcontroloftheFMTs,andB.HP-202,EnvironmentalMonitoringDuringEmergencies,providesinstructionsforpersonnelonFMTs.
REVISIONNo.:4PROCEDURENo.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGST.LUCIEPLANTPAGE:4of3
72.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTSNOTEOneormoreofthefollowingsymbolsmaybeusedinthisprocedure:gIndicatesaRegulatorycommitmentmadebyTechnicalSpecifications,ConditionofLicense,Audit,LER,Bulletin,etc.,andshallNOTberevisedwithoutFacilityReviewGroupreviewandPlantGeneralManagerapproval.Indicatesamanagementdirective,vendorrecommendation,plantpracticeorothernon-regulatorycommitmentthatshouldNOTberevisedwithoutconsultationwiththeplantstaff.2.1References1.St.LuciePlantTechnicalSpecificationsUnit1andUnit2(Section6.10.1)2.St.LuciePlantRadiologicalEmergencyPlan(E-Plan)3.FloridaPowerandLightTopicalQualityAssuranceReport(TQAR)4.FloridaRadiologicalEmergencyManagementPlanforNuclearPowerPlants5.E-PlanImplementingProcedures(EPIP-00-13)6.HP-200SeriesProcedures7.St.LuciePlantEmergencyResponseDirectory(ERD)8.QI-17-PSL-1,QualityAssuranceRecords9.EPA-400-R-92-001,EPAManualofProtectionActionGuidesandProtectiveActionsforNuclearIncidents,October,1991.10.FPLEnvironmentalSurveyTeamMap(10mileEPZ)11~HPForm100,EmergencyResponsePersonnelDoseMonitoring
REVISIONNO.:PROCEDURENO.:PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGPAGE:5of37EPIP-10ST.LUCIEPLANT
2.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTS(continued)2.2RecordsRequired1.Datacollectedandgeneratedbythisprocedureshouldberecorded.2.RecordedinformationshallbeforwardedtotheEmergencyPreparednessSupervisorfollowingtheevent,forreview,andarchivalinaccordancewithTechnicalSpecification6.10.1and,QI-17-PSL-1~2.3CommitmentDocuments1.NuclearEnergyPolicyonExposureLimitsforEmergencyResponsePersonnel,RevisiontoPolicyStatement,Ltr.No.JNO-HP-94-056,26October,1994.3.0RESPONSIBILITIES3.1TechnicalSupportCenterHealthPhysicsSupervisor(TSCHPS)1.TheTSCHPSorhisdesigneeisresponsiblefortheactivation,staffing,anddirectionoftheFieldMonitoringTeam(s).2.DirectionsfortheTSCHPSarefoundintheHP-200Seriesprocedures.3.2EOFHealthPhysicsManager1.TheEOFHPManagerisresponsibleforfieldmonitoringactivitieswhentheEOFisoperationalandaturnoverhasoccurredwiththeTSCHPS.2.DirectionsfortheEOFHPManagerarefoundinEPIP-06,ActivationandOperationoftheEmergencyOperationsFacility.
REVISIONNo.:PROCEDURENo.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGST.LUCIEPLANTPAGE:6of373.0RESPONSIBILITIES(continued)h3.3FieldMonitoringTeamCommunicator/Coordinator(FMTComm/Coord)1.IntheTSC,theFMTComm/Coord,withtheconcurrenceoftheTSCHPS,determinesthemonitoringpointsbaseduponmeteorologicalconditionsandpopulationzones.h2.CommunicateswiththeFieldMonitoringTeams(FMTs)viatheFPLradiosystemortelephone.3.,InformstheFMTsofallchangesinpertinentmeteorologicalandradiologicaldataaswellasinthestatusoftheemergencyandconditionsattheplant.4.ProvidesallsurveyresultstotheTSCHPS.5.TracksexposurelevelsofallmembersoftheFMTs.NOTEWhentheEOFisoperational,responsibilityfordeterminingsamplinglocationsfortheFMTstransferstotheEOF.TheTSCretainsthecommunicationinterfacewiththeFMTs.6.ProvidesallaccumulatedmonitoringdatatotheEOFonceitismanned.7.ConductsaturnoverwiththeFMTCoordintheEOF.3.4FieldMonitoringTeamCoordinator(FMTCoord)1~IntheEOF,FMTCoord,withtheconcurrenceoftheEOFHealthPhysicsManager,determinesthemonitoringpointsbaseduponmeteorologicalconditions,populationzones,andprevioussamplinglocations.2.CoordinatesfieldmonitoringactivitieswiththeFloridaBureauofRadiationControl~3.ProvidesallsurveyresultstotheEOFHPManager.
REVISIONNo.:PROCEDURENo.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGST.LUCIEPLANTPAGE:7of374.0DEFINITIONS4.1FloridaBureauofRadiationControl-adivisionoftheStateofFloridaDepartmentofHealth,responsibleforoff-siteradiologicalmonitoringandoperatingtheMobileEmergencyRadiologicalLaboratory(MERL).4.2Release(duringanydeclaredemergency)-1.Anyeffluentmonitorof(approximately)tentimesoronedecadeabovepre-transientvaluesOR2.HealthPhysicsdetectingairborneradioactivitylevelsinexcessof25percentDerivedAirConcentration(DAC)outsideofplantbuildingsduetofailureofequipmentassociatedwiththedeclaredemergency.
I REVISIONNO.:PROCEDURENO.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGST.LUCIEPLANTPAGE:8of375.0INSTRUCTIONS5.1ThissectionprovidesgeneralinformationandinstructionsformembersoftheEmergencyResponseOrganization(ERO).5.2Positionspecificchecklistsareincludedasattachmentstothisprocedure.5.3IndividualsspecificallydesignatedasmembersoftheEROareidentifiedintheERD.5.4Whennotified,EROmembersaretoreporttotheirEmergencyResponseFacility(ERF)asquicklyaspossibleifavailableandabletodoso.5.5ReportingtoAssignedFacility1.UponarrivalattheTSC:A.SigninonthestatusboardontheSouth(rear)wallofthefacilityinthespacecorrespondingtoyourposition(TSCHPCommunicator-oneoftwo).B.Obtaina"Player"badgeandplaceyourname(andpositiontitle,ifnecessary)onthebadgewithadryerasemarkerorinanyothernon-permanentmanner.C.Makeyourworkstation/locationoperational.D.NotifyyoursupervisorortheTSCSupervisorofyourreadinessstatus.E.AssistSecurityinestablishingaccountabilitybysigninginonaformsimilartoAttachment3A,TSCEROShiftStaffingandAccountabilityRoster,toprocedureEPIP-04,ActivationandOperationoftheTechnicalSupportCenter.'
REVISIONNO.:4PROCEDURENo.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGST.LUCIEPLANTPAGE:9of375.0INSTRUCTIONS(continued)5.5ReportingtoAssignedFacility(continued)2.UponarrivalattheEOF:A.PresentSecuritywithaformofpictureidentification.B.InformSecurityofyour"fitnessforduty"status.C.ObtainandwearapositionspecificaccessbadgeprovidedbySecurity.1.Placeyournameonthebadgewithadryerasemarkerorinanyothernon-permanentmanner.D.SigninontheStaffingBoardlocatedonthesouthwallofthe"bullpen"(room101)~E.Makeyourworkstation/locationoperational.F.Notifyyoursupervisorofyourreadinessstatus.g,5.6Onlycontrolledcopiesofnuclearsafety-relatedprocedures,drawings,andotheravailableplantinformationshallbeused.Non-controlleddocumentsordrawingsshouldbeverifiedwithacontrolledcopypriortouse.5.7Duringfacilitybriefings,stopwhatyouaredoing,payattention,andcontribute,asrequested.5.8Uponterminationoftheevent:1.Returnworkstation/locationtoanormalstateandassistinrestoringthefacilitytoareadycondition.2.Collectallsignificantinformationanddocumentation,suchasnotesandcompleteddatasheets(notboundintheprocedurenotebooks),andforwardthismaterialtothesupervisor/managerofthefacility.3.Theemergencyfacilitysupervisor/managerwillforwardthispaperworktotheEmergencyPreparednessSupervisor.ENDOFSECTION5.0 REVISIONNo'ROCEDURENo.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGST.LUCIEPLANTATTACHMENT1TSCFMTCOORD/COMMCHECKLIST(Page1of4)PAGE:10of37NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.ACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinpositionpackage)andreviewthegeneralinstructions.2.VerifyoperabilityofHPradio,refertoAttachment3,CommunicationsGuidelines,tothisprocedure.B.OPERATION1.ReviewAttachment4,FieldMonitoringGuidelines,tothisprocedure.NOTEFieldMonitoringTeamsmaybeactivatedatthediscretionoftheEC,butusuallyaredispatchedbasedonemergencyclassificationasfollows:Alert-dispatchoneteamtosurveyon-site/near-siteSiteAreaEmergency-dispatchthreeteams,oneforon-site/near-sitesurveysandtwoteamsforoff-sitesurveysGeneralEmergency-sameasforSiteAreaEmergency2.DeterminestatusofFMTsfromtheTSCHP.3.ReviewareastobesurveyedwiththeTSCHPSwiththeaidofAttachment5,PreselectedOn-siteMonitoringPoints,andAttachment6,PreselectedOff-siteMonitoringPoints.4.EstablishradiocontactwithFMTs.
1' REVISIONNO.:4PROCEDURENo.:PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGPAGE:11of37EPIP-10ST.LUCIEPLANTATTACHMENT1TSCFMTCOORD/COMMCHECKLIST(Page2of4)B.OPERATION(continued)INITIALNOTEWhentheEOFisoperational,responsibilityfordeterminingsamplinglocationsfortheFMTstransferstotheEOF.TheTSCretainsresponsibilityfor:1.CommunicationsinterfacewiththeFMTs.2.ExposurecontrolsforFMTs.3.UpdatingtheFMTsoncurrentconditions.5.Stepstooccurcontinuallywhilethisactivityisunderway:a.CommunicatewiththeFMTsviatheHPOff-siteChannel,refertoAttachment3,CommunicationsGuidelines.b.ProvideFMTswithsamplelocations.c.ProvideFMTswithsamplinginstructions(e.g.,openandclosewindowreadings,airsample,etc.).d.Recordfieldsurveydata,useAttachment7,FieldMonitoringTeamsSurveyResults,tothisprocedure,refertoAttachment7A,FieldMonitoringTeamsSurveyResults-Instructions.1.Usingcarbonpaper,makeacopyasthedataisenteredintotheform.Retaintheoriginal,providethecopytotheTSCAdministrativeStafftoupdatethestatusboard.
REVISIONNo.:4PROCEDURENo.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGST.LUCIEPLANTATTACHMENT1TSCFMTCOORD/COMMCHECKLIST(Page3of4)PAGE:12of37B.OPERATION(continued)INITIAL5.(continued)NOTE'tt,1.TheTSCHPSshallcontroltheexposurefortheFMTmemberstowithinFPLAdministrativeExposureLimitsof:A.5remTotalEffectiveDoseEquivalent(TEDE)ORB.50remcommittedDoseEquivalent(CDE)tothethyroidfromtheinhalationofradioiodine.$,2.FMTmemberexposureswillbecontrolledbymonitoringtheirDeepDoseEquivalent(DDE)andtheyshallberecalledfromfurtherexposurebeforeexceeding5remDDE.e.TrackexposurelevelsofFMTmembers,useAttachment8,DoseandSurveyDataWorksheet,tothisprocedure,refertoAttachment8A,DoseandSurveyDataWorksheet-Instructions.f.InformtheFMTsofallchangesinpertinentmeteorologicalandradiologicaldataaswellasinthestatusof,theemergencyandconditionsattheplant.g.ProvideallsurveyresultsandFMTexposurelevelstotheTSCHPS.1.Toestimatedose,doserate,orconcentration,refertoAttachment9,EstimatingDose,DoseRate,orConcentrationAtOtherDistances./R46.ProvideallaccumulatedmonitoringdatatotheEOF.7.ConductaturnoverwiththeFMTCoordintheEOF.
011 REVISIONNo.:PROCEDURENo.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGST.LUCIEPLANTATTACHMENT1TSCFMTCOORD/COMMCHECKLIST(Page4of4)PAGE:13of37C.CLOSEOUTINITIAL1.Terminatedallfieldsampling.2.RecalledallFMTstothesite.3.InstructedFMTstoreturnallequipmenttofootlockersattheSiteAssemblyStation.4.Closedoutthelog.5.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheTSCHPS.6.Returnedpositionnotebooktostoragecabinet.I/R4ENDOFATTACHMENT1
REVISIONNo.:PROCEDURENo.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGklST.LUCIEPLANTATTACHMENT2EOFFMTCOORDCHECKLIST(Page1of3)PAGE:14of37NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.ACTIVATIONINITIAL1.RefertoSection5.0ofthisprocedure(includedinpositionpackage)andreviewthegeneralinstructions.2.EstablishcommunicationswiththeFMTCoord/CommintheTSC.3.ConductturnoverwiththeFMTCoord/CommintheTSC.B.OPERATION1.ReviewAttachment4,FieldMonitoringGuidelines,tothisprocedure.2.ReviewFMTresultsreceivedfromtheTSCwiththeEOFHPManager.3.TakeresponsibilityforselectionofsamplinglocationsforFMTs.4.ReviewareastobesurveyedwiththeEOFHPManagerwiththeaidofAttachment5,PreselectedOn-siteMonitoringPoints,andAttachment6,PreselectedOff-siteMonitoringPoints.
REVISIONNO.:PROCEDURENO.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGST.LUCIEPLANTATTACHMENT2EOFFMTCOORDCHECKLIST(Page2of3)PAGE:15of37B.OPERATION(continued)"INITIAL'.Stepstooccurcontinuallywhilethisactivityisunderway:NOTETheFMTCoord/CommintheTSCmaintainsresponsibilityfor:1.CommunicationsinterfacewiththeFMTs.2.ExposurecontrolsforFMTs.3.UpdatingtheFMToncurrentconditions.a.CoordinatefieldmonitoringactivitieswiththeTSC.Ib.ProvideFMTswithsamplinginstructions(e.g.,openandclosedwindowreadings,airsamples,etc.).c.CoordinatefieldmonitoringactivitieswiththeFloridaBureauofRadiationControl~d.Recordfieldsurveydata,useAttachment7,FieldMonitoringTeamsSurveyResults,refertoAttachment7A,FieldMonitoringTeamsSurveyResults-Instructions.1.Usingcarbonpaper,makeacopyasthedataisenteredintotheform.Retaintheoriginal,providethecopytotheEOFRadStatusBoardKeepertoupdatethestatusboard.e.ProvideallsurveyresultstotheEOFHPManager.1.Toestimate'dose,doserateorconcentration,refertoAttachment9,EstimatingDose,DoseRateorConcentrationAtOtherDistances./R4f.PostfieldmonitoringlocationsandresultsontheEPZmap.
REVISIONNo.:PROCEDURENO.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGST.LUCIEPLANTATTACHMENT2EOFFMTCOORDCHECKLIST(Page3of3)PAGE:16of37C.CLOSEOUTINITIAL1.Terminatedallfieldsampling.2.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheEOFHPManager.3.ReturnedpositionnotebooktotheRecovery,Manager'soffice./R4ENDOFATTACHMENT2 REVISIONNo.:4PROCEDURENo.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGST.LUCIEPLANTATTACHMENT3COMMUNICATIONSGUIDELINES(Page1of3)PAGE:17of37NOTEIfcommunicationsareassociatedwithdrillorexercise,thestatement"Thisisadrill"shouldprecedeandfollowtheactualmessage.A.HPOFF-SITERADIOCHANNELAunique900MHzchannelforcommunicationswiththeoff-siteFMTs.Thetableradio,labeled"Off-siteRadio"canbeoperatedeitherbydepressingthe"transmit"buttonontheconsoleorbyremovingthehandsetanddepressingthe"push-to-talk"barinthehandset.The"xmit"lightislitduringtransmission.(Preferenceshouldbegiventousingthehandset.)kB.GENERALGUIDELINES1.Alwaysspeakclearly,firmly,andwithnormaltonewhenusinganycommunicationsystem.2.Thesenderandreceivershallbeclearlyidentified.3.Messagetext:a.Communicationmustbefreeofambiguity.Slangtermsshallnotbeused.Avoidtheuseofwordsthatsoundalike;forexample,avoidincreaseanddecrease,useraiseandlowerinstead.1b.Communicationsmustbespecific.Usenounnamesforplantequipment,notacronyms;forexampleuselowpressuresafetyinjectionpumpinsteadofLPSI.
REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGPAGE:18of37EPIP-10ST.LUCIEPLANTATTACHMENT3COMMUNICATIONSGUIDELINES(Page2of3)B.GENERALGUIDELINES(continued)3.(continued)c.Thephoneticalphabetshouldbeusedtoidentifyspecifictrain,bus,channel,orequipmentdesignations,notjustletteridentifier;forexample,refertothe1Alphaheaterdrainpump,notthe1Aheaterdrainpump.Thefollowingisthephoneticalphabettobeused:AAlphaJJulietSSierraBBravoKKiloTTangoCCharlieLLimaUUniformDDeltaMMikeVVictorEEpsilonNNovemberWWhiskeyFFoxtrot0OscarXX-RayGGolfPPapaYYankeeHHotelQQuebecZZuluIIndiaRRomeod.Thephoneticalphabetshouldnotbeusedforstringedletterreferences,acceptableacronyms,orlocationsymbols;forexample,ABbus,ACorDC,TSC,respectively.4.Acknowledgementandconfirmation(3-waycommunication)-messagesshallbecomprisedofpropertransmission,acknowledgement,andconfirmation.a.Themessageisproperlytransmittedfromtheoriginatortothereceiver.b.Themessagereceivershallacknowledgethecommunicationbygivingfunctionalrepeat-backtothemessageoriginator.Therepeat-backcanbeprovidedbyeitherparaphrasingorexplainingthemessageinone'sownwords,orbyverbatimrepeat-back.Inallcases,verbatimrepeat-backshallbe'usedforequipmentidentifiers.
REVISIONNo.:4PROCEDURENO.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGST.LUCIEPLANTATTACHMENT3COMMUNICATIONSGUIDELINES(Page3of3)PAGE:19of37B.GENERALGUIDELINES(continued)4.(continued)c.Ifthemessagereceiverdoesnotunderstandthemessage,he/sheshallaskforthemessagetoberepeated.d.Ifanincorrectrepeat-backisgiven,themessageoriginatorshallimmediatelycorrectthemiscommunicationwithastatementsuchas,"WRONG",followedbyrestatingthecorrectmessage.e.Themessageoriginatorshallconfirmtheacknowledgement(repeat-back)withastatementsuchas,"Thatiscorrect".5.UseoftheCallSignisnotnecessarywhencommunicatingwiththeHPOff-siteChannelradio(stationIDoccursevery30minutesautomatically).6.Priortotransmission,ensurethatinformationhasbeenverifiedandapprovedbytheappropriateauthority,asnecessary.7.EnsurethatanyincomingpertinentinformationisprovidedtotheTSCHPS.R8.Maintaindocumentationofanysignificantinformationprovidedorreceived.ENDOFATTACHMENT3 REVISIONNo.:'PROCEDURENo.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGST.LUCIEPLANTATTACHMENT4FIELDMONITORINGGUIDELINES(Page1of1)PAGE:20of37~PuroeeThepurposeoffieldmonitoringistodetectandcharacterizeanairborneplumeofradioactivematerial.Thiscouldbetheonlysourceofinformationforanunmonitoredrelease.StrateqSr1.Disperseteamsasfollows:OwnerControlledArea,oneteamLeftandrightoftheplumecenterlineatsomedistance(e.g.,2-5miles),twoteams2.Determineifareleaseisinprogress(i.e.,hasanyFMTreportedsurveymeterreadingsgreaterthanbackground).3.Estimateplumelocationbyusingwindspeed,winddirection,andtimeofrelease.4.5.Ifdosesorprojectionsarenotlimiting,attempttocharacterizeplumewidthandlocationofplumecenterline(=highestreadingonatransversepathacrosstheplume).Toassessradiologicalcomposition,obtainandanalyzeanairsampletoestablishaniodinetonoblegasratio.6.Attempttodetermineactualplumeboundaries,usepredesignatedmonitoringlocationsasreferencepoints,toensureappropriateProtectiveActionsareinplace(orrecommended)forareasimpactedbytheplume.7.CollaboratewithStateteamstoincreasedatacollectedandmaximizeresources(coveraslargeanareaaspossibleorneeded).8.Resultsoffieldmonitoringprovidefeedbacktodosecalculations/assessment;SURVEYDOSERATESSHOULDNEVEREXCEEDPROJECTEDDOSERATES.ENDOFATTACHMENT4
REVISIONNo.:PROCEDURENO.:PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGPAGE:21of37EPIP-10ST.LUCIEPLANTATTACHMENT5PRESELECTEDON-SITEMONITORINGPOINTS(Page1of4)KIIjCCzClz4~oI/'4fPiss4~0BDUNDARYmtoisoqo0:858o~ALIIS4~0J2.8+8q8'++IoQ1218,o~;jyss$,'S8,S;SS20cS822++gO019000+IIQso15,g,o'cg,>oo14OZ0goo.hII'IIjm86413INTAKECANAL1281080:SgPSIi24I258400:Sg8SBPSAS$8580$408527I,s',sCCCSAIICSCAIIAA0P!o:S88(8IS,'S8:8529CSS8o82I8400:Sg8+8580II8S08iII~:.A@:S'00KI-z0O0z0zLLJO0OI-zI-LOCATIONNAMEIS'RED'+MONITORINGPOINTNUMBER(PIPS/EPIP.I///AttS-RSI8'>>U315SITEBOUNDARY/R4
REVISIONNO.:4PROCEDURENO.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGST.LUCIEPLANTATTACHMENT5PRESELECTEDON-SITEMONITORINGPOINTS(Page2of4)PAGE:22of37MONITORINGPOINTLOCATIONDISTANCEFROMPLANTEPZ~MILESSECTORRed-1Red-2Red-3Red-4Red-5Red-6Red-7Red-8MetTower,SiteAssemblySta.GateA8RteA1AGateB8RteA1A0.50.30.25GateC8RteA1AGateD8RteA1AGateE&RteA1A0.250.30.33GateF&RteA1A(northsideofintakecanal)0.45DischargeCanalBridge@RteA1A0.2ADEGRed-9Red-10Red-11Red-12Red-13GateG&RteA1ABallParkRoad(firstnorthtowestboundcorner)BallParkRoad(emilemarkeronberm)BallParkRoad(ecornerturningnorth)BallParkRoad(postinberm,midwaybetweenmonitoringpointsRed12&14)0.60.50.460.50.38GGG,HH,J 0aII REVISIONNo.:PROCEDURENo.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGST.LUCIEPLANTATTACHMENT5PRESELECTEDON-SITEMONITORINGPOINTS,(Page3of4)PAGE:23of37MONITORINGPOINT"LOCATIONDISTANCEFROMPLANTEPZ~MILESSECTORRed-14Red-15Red-16Red-17Red-18Red-19Red-20Red-21BallParkRoad(@leftturntowardsGunRange/PicnicPavilion)GateW-25(eastsideofGunRange)PicnicPavilionIntersectionofBoatRampturnoff8roadtoFireTrainingAreaGateW-26(westsideofGunRange)BoatRampFitnessTrail(.5mi.sign)Road,northsideofBigMudCreek(oppositeBoatRamp)0.30.40.330.320.50.360.50.35M,N'Red-22Road,northsideofBigMudCreek(oppositeCityWaterStorageTanks)0.30QRed-23Red-24Red-25Red-26Road,northsideofBigMudCreek(oppositeBargeSlip)TurtleBeachParkingLotLargefootbridgeSmallfootbridge0.40.620.540.51RB,C REVISIONNO.:PROCEDURENo.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGST.LUCIEPLANTATTACHMENT5PRESELECTEDON-SITEMONITORINGPOINTS(Page4of4)PAGE:24of37MONITORINGPOINTLOCATIONDISTANCEFROMPLANTEPZ~MILESSECTORRed-27Red-28Red-29Red-30Red-31ConcretepowerpadDischargeCanalHeaderHalfwaybetweenDischarge8IntakeCanalHeadersIntakeCanalHeaderWaltonBeachentranceroad(forkintheroad)0.50.50.520.60.8DGENDOFATTACHMENT5 4LtB'll REVISIONNO.:PROCEDURENo.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGST.LUCIEPLANTATTACHMENT6PRESELECTEDOFF-SITEMONITORINGPOINTS(Page1of5)PAGE:25of37(A)N10mHes0$R10R910P908Ft18fceR76Al4(8)NNEN10EO(N)WMd@yP7N6N5P3N2(c)NE(D)ENE(E)EMStyMBMeM3J3(P)ESEWL10M7LeKeLBL7K6KSIPt.St.WCISIIIW(K)oae0J5.LyttloCountS(J)yoH4StUAB'~SS(H)(G)SE(EP1P164.HyPGj REVISIONNo.:4PROCEDURENo.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGST.LUCIEPLANTATTACHMENT6PRESELECTEDOFF-SITEMONITORINGPOINTS(Page2of5)PAGE:26of37MONITORINGPOINTLOCATIONDISTANCEFROMPLANTEPZ~MILES,SECTORR2R7R9S.R.A1A,NNWofplantsite(LittleMudCreekBridge)IntersectionofS.R.A1AandClipperBlvd.(EntrancetoOceanVillage)S.R.A1A,NNWofplantsite(WestofFireDept.atSiren)2.36.7'8.6RRRR10EastsideofNorthBridge(S.R.A1A)9.6RQ4Q5,IntersectionofIndianRiverDr.(S.R.707)andWhiteRd.,EastofWhiteCityandSouthofFortPierceIntersectionofIndianRiverDr.(S.R.707)andRioVistaDr.3.75.4QQQ6Q7IntersectionofU.S.1andEdwardsRd.(S.R.611.B),SouthsideofFt.Piercenearrailroadcrossing6.4IntersectionofOleanderBlvd.(S.R.605)andVirginiaAve.QQQ8Q9Q10IntersectionofU.S.1andDelawareAve.IntersectionofOkeechobeeRd.(S.R.70)andHartmanRd.(S.41stSt.nearsiren)IntersectionofOrangeAve.(S.R.68)andAngleRd.8.19.19.6QQQ P
REVISIONNo.:PROCEDURENO.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGIIST.LUCIEPLANTATTACHMENT6PRESELECTEDOFF-SITEMONITORINGPOINTS(Page3of5)PAGE:27of37MONITORINGPOINTP3LOCATIONIntersectionofBartowSt.andYuccaDr.DISTANCEFROMPLANTEPZ~MILESSECTOR3.2P5P7IntersectionofU.S.1andMidwayRd.(S.R.712)WhiteCity5.2IntersectionofMidwayRd.(S.R.712)andChristiansenRd.(atsiren),7.1P9P10N2N5IntersectionofMcNeilRd.andEdwardsRd.(611B)IntersectionofOkeechobeeRd.(S.R.70)andl-95S.R.707Westofplantsite(atsiren)IntersectionofU.S.1andSaegerRd.(southofWhiteCity)IntersectionofSt.JamesDr.andAirosoBlvd.8.79.72.04.86.4NNNN10St.Lucie'sEOF,IntersectionofS.R.712andI-9510.2NM3M6EastendofN.MediterraneanBlvd.IntersectionofU.S.1andPrimaVistaBlvd.,PortSt.LucieIntersectionofPrimaVistaBlvd.andAirosoBlvd.3.44.86.5 A0 REVISIONNo.:4PROCEDURENo.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGST.LUCIEPLANTATTACHMENT6PRESELECTEDOFF-SITEMONITORINGPOINTS(Page4of5)PAGE:28of37MONITORINGPOINTLOCATIONIntersectionofAirosoBlvd.andWhitmoreDr.DISTANCEFROMPLANTEPZ~MILESSECTOR7.3L5L6IntersectionofPrimaVistaBlvd.andBayshoreBlvd.IntersectionofU.S.1andWaltonRd.,PortSt.LucieIntersectionofFlorestaDr.andThornhillDr.7.84.86.4L7IntersectionofWhitmoreDriveandPortSt.LucieBlvd.7.2L8L10IntersectionofPortSt.LucieBlvd.andFla.TurnpikeIntersectionofPortSt.LucieBlvd.andCairoAve.8.410K5IntersectionofLennardRd.andBlossomRd.4.7K6K7IntersectionofU.S.1andPortSt.LucieBlvd.,PortSt.LucieIntersectionofMorningsideBlvd.andWestmorelandBlvd.5.77.1K8J3IntersectionofMorningsideBlvd.andRiverVistaDr.IntersectionofWaltonRd.andIndianRiverDr.(S.R.707)8.03.4 REVISIONNO.:4PROCEDURENo.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGST.LUCIEPLANTATTACHMENT6PRESELECTEDOFF-SITEMONITORINGPOINTS(Page5of5)PAGE:29of37MONITORINGPOINTJ5J7J9J10H4LOCATIONIntersectionofIndianRiverDr.(S.R.707)andMockingbirdHillRd.(nearsiren)IntersectionofJensenBeachBlvd.(S.R.707A)andSavannahRd.(S.R.723)IntersectionofWrightBlvd.(S.R.723)andU.S.1MartinMemorialHospitalS.R.A1A,southofplant(atsiren)NorthtoentrancetoNettle'sIslandDISTANCEFROMPLANTEPZ~MILESSECTOR4.77.09.210.04.0H7H10IntersectionofS.R.A1AandtheJensenBeachturnoff(A1AAlt.)(atsiren)'IntersectionofS.R.A1AandOceanBlvd.(ElliottMuseum)6.99.8ENDOFATTACHMENT6 REVISIONNO.:4PROCEDURENO.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGST.LUCIEPLANTATTACHMENT7FIELDMONITORINGTEAMSSURVEYRESULTS(Page1of1)PAGE:30of37nEEo0ClCO(gQ.-uj)P-oIEO0mmmmOM~0CEAg)6$C)QCdQI-IL-Dg8Qn~O~MCQN-~0Ig~8OOE~l:0)ENDOFATTACHMENT7
REVISIONNo.:PROCEDURENo.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGST.LUCIEPLANTPAGE:31of37ATTACHMENT7AFIELDMONITORINGTEAMSSURVEYRESULTS-INSTRUCTIONS(Page1of2)ThefollowinginstructionsareprovidedforthecompletionofAttachment7.ThecolumnsinAttachment7havebeennumberedfrom1-9.Anexplanationofthedataexpectedineachcolumnisprovidedbelow.Priortoenteringdataintothetable,placethedateatthetopofthepage.Usemultipleformsasnecessaryandnumbersequentially.Printyournameatthebottomofeachformandinitial.~TlS-Tliitttitttydtgttditttold,timeshouldbebasedona24hourclock(e.g.,2a.m.=0200hoursand7p.m.=1900hours).2.WindDirection-ThisisthedirectionFROMwhichthewindisblowing,thisinformationispostedonandshouldbeobtainedfromthedoseassessmentstatusboard.3.AffectedSectors-Theaffectedsectorsaredeterminedbythewinddirection,3(orpossibly4)sectorsareaffected,thisinformationispostedonandshouldbeobtainedfromthedoseassessmentstatusboard.4.Team-Thereare3FPLFMTs,usuallydesignatedR=red,0=orange,andB=blue,theRteamisusuallythefirstdispatchedandconductssurveyson-site/near-site,theothertwoteamsgooff-site.5.MilesfromPlant-Thisisdeterminedbythesamplinglocation.A.On-site/near-siteTeam(=RedTeam)-MonitoringlocationswithintheOwnerControlledAreaaregiveninAttachment5,PreselectedOn-siteMonitoringPoints.Eachlocationisdesignatedas"Red-monitoringpointnumber"(e.g.,Red-25).Thedistancefromtheplantaswellasadescriptionofthelocationofeachmonitoringpointisprovidedaspartoftheattachment.B.Off-siteTeams(=OrangeandBlueTeams)-Monitoringlocationswithinthe10mileEPZ,outsidetheOwnerControlledArea,aregiveninAttachment6,PreselectedOff-siteMonitoringPoints.Ifapreselectedmonitoringpointisused,thedesignationgivesbothsectoranddistance(e.g.,pointR9isapproximately9milesfromtheplantinSectorR).Thepreselectedmonitoringpointscanalsobeusedtoestimatedistances.
14't41 REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGPAGE:32of37EPIP-10ST.LUCIEPLANTATTACHMENT7AFIELDMONITORINGTEAMSSURVEYRESULTS-INSTRUCTIONS(Page2of2)6.~SIti-It6IIditiglttId,designationisprovidedforeachpointinbothAttachments5and6.Ifotherpointsareused,theFMTshouldprovideaclearlocation(e.g.,distancefromandnameof,closestintersectionorlandmark).g.~gRI6-a.PlumeDDE(mrem/hr)-Thisisameasureofexternalexposure,measuredbyasurveymeter(doseratemeter).Therecordedvalueistheclosedwindowreadinginmilliremperhour.b.ThyroidCDE(mrem/hr)-Thisisameasureofthyroiddoserateduetoinhalationofradioiodines.ThethyroiddoserateiscalculatedusingAttachment7B,EstimateofThyroidDoseRate,tothisprocedure.Therecordedvalueisinmilliremperhour.8.SurveGreaterThanPro'ectedY/N-Fieldmonitoringresultsprovideimportantfeedbackontheaccuracyofdoseprojections.FieldreadingsshouldbecomparedtoprojecteddosesanddoseratesandreviewedwiththeTSCHPSorEOFHPManager,asappropriate.Example:comparethemeasureddoserateat5milesat1045withthedoserateat5milesfromthe08302hourprojection,fieldreadingsshouldneverexceedprojections.9.Comments-Recordanysignificantextraorusefulinformation.ENDOFATTACHMENT7A REVISIONNo.:PROCEDURENo.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGST.LUCIEPLANTATTACHMENT7BESTIMATEOFTHYROIDDOSERATE(Page1of1)PAGE:33of37FieldMonitoringTeamswilltakedirectradiationreadingsandairsamplesand,analyzeairsamplesforradioiodine(I-131)concentration.Radioiodine(l-131)analysisshouldnormallybeperformedu'singportableanalyzerswithscintillationdetectors.2.ThyroidDose(CDE)Rate,fromtheinhalationofiodines,isestimatedusingthefollowingequation:A(mrem/hr)=1.3E+9xBxC(uCi/ml)WhereA='hyroidDose(CDE)RateB=FactorfromtablebelowC=Iodine131concentrationmeasuredinthefield(fromHP202.1,EnvironmentalAirborneActivityCalculationForm.)TimeisHourssinceReactorTripTimehourFactor1.451.431.411.401.381.371.351.341.33Timehour91011121314152436Factor1.321.301.291.281.281271.261~191~133.PluginvaluesforBandCtocalculatetheThyroidDose(CDE)Rate'.(mrem/hr)=1.3E+9x(uCi/ml)ENDOFATTACHMENT7B REVISIONNO.:PROCEDURENO.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGST.LUCIEPLANTATTACHMENT8DOSEANDSURVEYDATAWORKSHEET(Page1of1)PAGE:34of37NOTERecallaFieldMonitoringTeamfromfurtherexposurebeforeeithermemberexceeds5,000mrem(DDE).Team:MemberA:MemberB:Date:j~SurveyLocationTimeofSectorSurvey45MeasuredMeasuredGammaDoseiodine-131Rate(mrem/hr)(pCi/ml)OPENCLOSEDOPENCLOSEDOPENCLOSEDOPENCLOSEDOPENCLOSEDOPENCLOSEDOPENCLOSEDOPENCLOSEDOPENCLOSEDOPENCLOSEDOPENCLOSED6TimeinPlume(minutes)AAAAAAAAA7DRDReading(mrem)8ThyroidDose(mrem)ENDOFATTACHMENT8/R4
REVISIONNo.:PROCEDURENO.:PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGPAGE:35'of37EPIP-10ST.LUCIEPLANTATTACHMENT8ADOSEANDSURVEYDATAWORKSHEET-INSTRUCTIONS(Page1of2)ThefollowinginstructionsareprovidedforthecompletionofAttachment8.ThecolumnsinAttachment8havebeennumberedfrom1-7.Anexplanationofthedataexpectedineachcolumnisprovidedbelow.OnedatasheetistobeusedforeachFMT(red,orange,blue).Theteamandthenamesofthetwomembersofeachteamaretobefilled-inatthetopoftheform.Priortoenteringdataintothetable,placethedateatthetopofthepage.Usemultipleformsforeachteamasnecessaryandnumbersequentially.Printyournameatthebottomofeachformandinitial.~SLti-IfgIIditi~ItiId,designationisprovidedforeachpointinbothAttachment5,PreselectedOn-siteMonitoringPoints,andAttachment6,PreselectedOff-siteMonitoringPoints.Ifotherpointsareused,theFMTshouldprovideaclearlocation(e.g.,distancefromandnameofclosestintersectionorlandmark).2.Sector-The10mileEmergencyPlanningZone(EPZ)aroundSt.LuciePlantisdividedinto16sectorswhicharelabeledA-R(Iand0arenotused).'Identifythesectorinwhichthefielddatawascollected.RefertotheFPLEnvironmentalSurveyMap(10mileEPZ)postedintheTSC.The10mileEPZisalsoshownonPage1ofAttachment6.~.~TfS-Thihghtydtghdihdid,timeshouldbebasedona24hourclock(e.g.,2a.m.=0200hoursand7p.m.=1900hours).4.MeasuredGammaDoseRatemrem/hr-Thisisdirectradiationmeasureofdoseratefromasurveymeter,recordedinmilliremperhour.Bothanopenandclosedwindowreadingshouldberecorded.Theopenwindowreadingallowsforanestimateofbetadose.5.MeasuredIodine-;131uCi/ml-ThisisanairsampleinwhichtheconcentrationofIodine-131ismeasuredinacertainvolume,recordedinmicrocuriespermilliliter.
REVISIONNo.:PROCEDURENO.:EPIP-10PROCEDURETITLE:OFF-SITERADIOLOGICALMONITORINGST.LUCIEPLANTPAGE:36of37ATTACHMENT8ADOSEANDSURVEYDATAWORKSHEET-INSTRUCTIONS(Page2of2)6.TimeinPlumeMinutes-ThisisthetimetheFMTmembersactuallyspentintheplume.Itisrecordedasaseparatemeasureforeachteammember.Thevalueisrecordedinminutes.7.~DRO~Ch-TtiiOi~digOit(ORO)di~thatshouldberecordedeachtimetheFMTmemberexitstheplume.TheDRDrecordsacumulativedose.Thevalueisrecordedinmillirem.ElectronicPersonalDosimeters(EPDs)mayalsobeusedwiththeDRDs.8.ThroidDosemrem-ThyroiddoseisdeterminedbymultiplyingthedoseratecalculatedinAttachment7B,EstimateofThyroidDoseRate,timesthetimeintheplume(column6).,Thevalueisrecordedinmillirem./R4ENDOFATTACHMENT8A
PAGE:REVISIONNo.:4PROCEDURENo.:EPROCEDURETITLE:OFF-SITERADIOLOGICALMONITORING37of37ST.LUCIEPLANTDISTANCES(Page1of1)PIP10ATTACHMENT9ESTIMATINGDOSEDOSERATEORCONCENTRATIONATOTHERCAUTIONAswithanyapproximation,cautionandjudgementshouldbeappliedwhenusinganestimatedvalue.1.Toestimatedose,doserateorconcentrationatadistanceotherthanwheresurveysweretaken,usethefollowingequation:E=M*(MD/ED)'hereE=estimateddose,doserateorconcentrationED=distanceatwhichanestimateddose,doserateorconcentrationisdesiredM=actualmeasureddose,doserateorconcentrationMD=distanceatwhichtheactualmeasureddose,doserateorconcentrationwastakenZ=exponentbasedonstabilityclassStabilitClassZValueA,B2.0C,D1.5D,E,F1.0(basedonEPA-400,Chapter5)/R4ENDOFATTACHMENT9 Title:FPLST.LUCIEPLANTHEALTHPHYSICSPROCEDURESAFETYRELATEDEMERGENCYEQUIPMENTProcedureNo.HP-90CurrentRev.No.37EffectiveDate:12/20/00ResponsibleDepartment:HEALTHPHYSlCSRevisionSummaryRevision37-DeletedreferencestoSTA,revisedTSCcommosurveyreferenttoEPIP-13,revisedreplacementtimeforfailedmajorequipmentwithintheOCAto24hours,madeeditorialchanges,andrevisedattachments/formsfromHP-206tobeincludedine-kits.(J.R.Walker,12/07/00)Revision36-AddedcheckoffaxmachinesandcopymachinesanddeletedunnecessaryletterreferencestospecificcopiesofERD.(SteveKnapp,10/28/99)Revision35-RevisedreferencestodeleteC-111andaddedCOP-06.11.RevisedtextandcheckliststodeleteC-111andaddedCOP-06.11.UpdatedEPSupervisorinformation.Madeadministrativechanges.(RickWalker,06/30/99)R'OOPSLPROCEDUREFAODVCTIONRevisionFRGReviewDate3712/07/00RevisionFRGReviewDate06/24/75ApprovedByK.N.HarrisPlantGeneralManagerApprovedByR.G.WestPlantGeneralManagerN/ADesignatedApproverN/ADesignatedApprover(minorcorrection)ApprovalDate09/11/75ApprovalDate12/07/00SOPSDATEDOCTPROCEDUREDOCNHP-90SYSCOMPCOMPLETEDITM37
Page2of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENT1.0TITLE:EMERGENCYEQUIPMENT2.0REVIEWANDAPPROVAL:Seecoversheet.3.0PURPOSE:ThisproceduregivestheinstructionstobeusedwhenconductinginventoriesandmaintenanceofHPEmergencyKits.4.0PRECAUTIONSANDLIMITATIONS:4.1Itemsubstitutionisauthorizedonlyifthesubstituteditemiscomparable/equivalenttotheoriginalequipment.4.2Allemergencyequipmentshallbecheckedandinventoriedonceeachmonthandwithinfive(5)workingdaysfollowingeachuse.4.3ItemsfoundinEmergencyKitswhichdonotappearontheinventorysheetsshallberemovedandrelocatedinaccordancewiththeinstructionsofaHealthPhysicsSupervisor.Thisdoesnotapplyathospitals,whereFPLandnon-FPLsuppliesmaybecollocatedinaccordancewithhospitalstaffpreferences.4.4Inyearsendinginzero(0)orfive(5),allinventoriedequipmentshouldbeevaluatedwithrespecttoage,wearandneedforreplacembntorupgrade4.5KitchecksourcesusedtotestinstrumentoperabilityshouldNOTbestorednearthekitTLDs.4.6Silverimpregnatedzeolitecartridgesmaybeproperlystoredforaperiodoffiveyearsfromthedateofmanufacture.
Page3of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENT4.0PRECAUTIONSANDLIMITS:(continued)4.7ElectronicPersonnelDosimeters(EPD)storedintheControlRoomsandoffsitemonitoringteamkitsshallbeprogrammedto:1~DisplaybothDoseandDoseRate.2.Activatebypushingthepushbutton.3.Alarmonadoseof4.5RandaDoseRateof10R/hr.4.8WhennotifiedbyEmergencyPlanningthatarevisiontoaprocedurecontainedintheHPEmergencyKitshasbeenissued,HPshouldupdatetheprocedurewiththenewrevisionwithinfive(5)workingdays.4.9FullfacerespiratorsintheEmergencyKitsshallbevisuallyinspectedinaccordancewiththerequirementsofHPP-62,InspectionandMaintenanceofRespiratoryProtectionEquipment.5.0RELATEDSYSTEMSTATUS:NONE
6.0REFERENCES
- 6.1St.LuciePlantRadiologicalEmergencyPlan(E-Plan)6.2E-PlanImplementingProcedures(EPIP00-13)6.3St.LuciePlantEmergencyResponseDirectory(ERD)6.4FloridaPower8LightCompany,St.LuciePlantRecoveryPlan6.5HPP-62,"InspectionandMaintenanceofRespiratoryProtectionEquipment."6.6HPP-70,"PersonnelContaminationMonitoringandDecontaminationProcedure."6.7HPP-101,"IdentificationandReportingofRadiologicalEvents."6.8HealthPhysicsProcedures,HP-200Series6.9COP-06.06,"GuidelinesforCollectingPostAccidentSamples."
Page4of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENT
6.0REFERENCES
- k6.10COP-06.11,"EstablishingRemoteLaboratoryforAnalysesofAccidentSamples."6.11OP1-0010125,"ScheduleofPeriodicTests,ChecksandCalibrations."6.12OP2-0010125,"ScheduleofPeriodicTests,ChecksandCalibrations."6.13NRCGenericLetter91-14,EmergencyTelecommunications.6.14NRCAdministrativeLetter94-04,ChangeoftheNRCOperationsCenterCommercialTelephoneandFacsimileNumbers.6.15OSHA1926.404(b)(iii),AssuredEquipmentGroundingConductorProgram.6.16PMAInumberPM97-04-006,EPIPUpdatesinHPEKits6.17PMAInumberPM97-04-147,ShavingSuppliesinHPEKits$36.18PMAInumberPM97-07-142,First-aidKitinSiteAssemblyStation$46.19PMAInumberPM99-09-076,FaxandCopyMachineTests7.0RECORDSREQUIRED:/R377.1Inventorysheetsforeachofthelocationslistedin8.2below(HP-90)-Attachments¹1-7shallbemaintainedintheplantfilesinaccordancewithQl-17-PSL-1"QualityAssuranceRecords."
Page5of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENT8.0INSTRUCTIONS:8.1Priortoconductinginventoriesofthekits:AscertainthecurrentrevisionnumberofEmergencyPlanningdocuments.A.ContacttheNuclearRecordsVaultfor1,2and3below.B.AccesstheControlledElectronicProcedureIndex(inLotusNotes)forallotherdocuments(4-10below).NOTEKitsdesignatingthatfullsetsofEPIPsand/orHP-200seriesproceduresareavailable,shallcontainalltheproceduresinTable1and/orTable2,asapplicable.1.St.LuciePlantRadiologicalEmergencyPlan(E-Plan)2.St.LuciePlantEmergencyResponseDirectory(ERD)3.FloridaPower8LightCompany,St.LuciePlantRecoveryPlan4.EPIPs(seeTable1)5.HP-200Series(seeTable2)6.HPP-70,"PersonnelContaminationMonitoring,"(FormHPP-70.1,PersonnelSkinandClothingContaminationReport)7.HP-90,"EmergencyEquipment"8.HPP-101,"IdentificationandReportingofRadiologicalEvents,"(FormHPP-101.1,RadiologicalEventReport)9.COP-06.06,"GuidelinesforCollectingPostAccidentSamples"10.COP-06.11,"EstablishingRemoteLaboratoryforAnalysesofAccidentSamples."Theproceduredistributionislistedontheinventorysheet./R37 Page6of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENT8.0INSTRUCTIONS:(continued)8.1(continued)2.ContactEmergencyPlanningtodetermineifanyprocedurerevisionsareavailabletobeaddedtotheemergencykits.3.ContactLandUtilizationtoarrangeforaccesstotheEmergencyOperationsFacility(EOF),ifnecessary(i.e.,notontheaccesslist).8.2Inventoryallitems,verifyingthatthepropersuppliesarepresent.Usetheappropriateinventorylist.1.Attachment1-Unit1ControlRoom/TechnicalSupportCenterEmergencyKit2.Attachment2-Unit2ControlRoomEmergencyKit3.Attachment3-OperationalSupportCenterEmergencyKit4.Attachment4-SiteAssemblyStationEmergencyKit5.Attachment5-SiteAssemblyStation-FieldMonitoringTeamEmergencyKit(complete1attachmentforeachkit)6.Attachment6-EmergencyOperationsFacilityEmergencyKit7.Attachment7-HospitalEmergencyKit(completeoneattachmentforeachhospital)8.3Anyequipmentwhichisoutofcalibration,failstheoperabilitycheck,orappearstobeunusableshallbereplaced.1.Anasteriskdesignatesamajorpieceofequipment.Ifamajorpieceofequipmentisfoundtobedeficient,theequipmentmustbereplacedasfollows:A.ForEmergencyKitslocatedwithintheOwnerControlledArea-within24hours./R37B.ForEmergencyKitslocatedoutsidetheOwnerControlledArea-within48hours.
Page7of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENT8.0INSTRUCTIONS:(continued)8.4Quantitiesofnon-asteriskedinventoryitemsmaybeexceeded,butshallnotbelessthanthatindicatedontheattachment.Anitemfoundtobeinaquantitylessthanthatlistedontheattachmentshallbereplenishedbythetimeofthenextinventory.8.5PerformoperabilitychecksofinstrumentsinaccordancewithAppendixA,OperabilityInstructions.8.6Verifythatdosimetryiscurrent,NOTENotalldosimetryisrequiredineachEmergencyKit.DirectReadingDosimeter(DRD).DRDsarecalibratedeverysix(6)months.A.0-500mRB.0-5RC.0-20RD.0-100R2.ElectronicPersonalDosimeter(EPD)A.AlarmSetpoint,Dose:4.5RB.AlarmSetpoint,DoseRate:10R/hr3.ThermoluminescentDosimeter(TLD).TLDsarechangedoutinthekitsonasemi-annualbasis.A.WholeBodyB.ExtremityC.FingerRings Page8of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENT8.0INSTRUCTIONS:(continued)8.7VerifythatrespiratorsarevisuallyinspectedasprescribedinHPP-62,InspectionandMaintenanceofRespiratoryProtectionEquipment.8.8Verifythatsilverzeolitecartridgesarecurrent.InformtheHealthPhysicsTechnicalSupervisorwhenthepostedshelflifeofthecartridgesiswithinthree(3)monthsofexpiring.8.9ExtensioncordsstoredintheEmergencyKitsshallbetestedorreplacedwithtestedextensioncordsafteruse.1.Atestingdeviceisavailableineachkitwhichhasextensioncords.2.Recordtestresultsorcordreplacementinthe"Remarks"section(e.g.,allextensioncordspassed;oneextensioncordreplacementduetotestfailure).NOTETheportablecountrateinstruments(friskers)andthedualchannelanalyzersareexemptfromthisinstructionbecausetheyrequirere-chargeablebatteries.Spareinstrumentsareavailableasbackupsshouldoneoftheseinstruments(friskers)experiencebatteryfailure.8.10Verifythatthereisasufficientsupplyofsparebatteriesavailableforallinstrumentsandequipmentrequiringbatteries.Replaceanybatteryorpackageofbatterieswhichisapproaching(withinone(1)month)orexceedsitsexpirationdateorshelflife.2.EveryJanuaryandJuly,inspectbatteriesinallinstrumentsandequipmentforsignsofdeteriorationorleaksandreplace,asnecessary.8.11Verifythattheprocedurescontainedinthekitarethecurrentrevisions,ifnot,replaceprocedurewithacontrolledcopyofthecurrentrevision.8.12PerformmonthlytestofcommunicationsequipmentwithstateandlocalgovernmentsandtheNRCinaccordancewithAppendixB,InstructionsforTestingEmergencyCommunicationsEquipment.
Page9of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENT8.0INSTRUCTIONS:(continued)8.13Completetheinventoryformasfollows:1.Indicatetheresultsoftheoperabilitychecksofthekitinstrumentsbymarking"Pass"or"Fail"ontheappropriateattachment.Recordanydiscrepancyinthe"Remarks"section.2.Dosimetry,dress-outsupplies,andotherequipmentshouldbeevaluatedagainstthe"MinimumQuantity"requirementsaslistedontheinventoryform.Recordthe"AsFound"conditionaseither"Pass"or"Fail".Indicateanydiscrepancyinthe"Remarks"section.3.Reviewalldocuments,procedures,andlogsandshowwhethertheyare"Available"or"Unavailable".Recordanydiscrepancyinthe"Remarks"section.4.Indicatetheresultsofthecommunicationstestsbymarking"Pass"or"Fail"ontheappropriateattachment.Recordanydiscrepancyinthe"Remarks"section.5.Uponcompletionoftheinventory,closeandlockthekitandsignanddatetheattachmentintheblankslabeled"Inventoriedby"and"Date".8.14Acopyofeachcompletedinventory(attachment)isrequired.1~ConspicuouslypostthecopyoftheinventoryonthefrontoftheEmergencyKitforreadyreferencebythenextuserofthekit.2.ProvidetheoriginaltoanHPSupervisorforreview.8.15AnHPSupervisorshallreviewallcompletedinventories.1.APMAIistobeissuedbythereviewingHPSupervisorforeachitemwhichisnotaddressedin8.3or8.4aboveandcannotberesolvedwithinfive(5)workingdaysofidentification.ThePMAInumberistoberecordedinthe"Remarks"sectionoftheaffectedattachment.
Page10of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENT8.0INSTRUCTIONS:(continued)8.15(continued)2.Signanddatethereviewedinventoriesinthe"Reviewedby"and"Date"blanksoneachattachment.3.AcopyofeachreviewedattachmentistobeforwardedtoEmergencyPlanning.4.TheoriginalsofallreviewedattachmentsaretobesenttotheNuclearRecordsVault.
Page11of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTTABLE1EMERGENCYPLANIMPLEMENTINGPROCEDURESEPIP-00-EPIP-01-EPIP-02-EPIP-03-EPIP-04-EPIP-05-EPIP-06-EPIP-07-EPIP-08-EPIP-09-EPIP-10-EPIP-11-EPIP-12-EPIP-13-"Discovery8IdentificationofanEmergencyCondition(IncludingChemical,FireandNaturalEmergencies)""ClassificationofEmergencies""DutiesandResponsibilitiesoftheEmergencyCoordinator""EmergencyResponseOrganizationNotification/StaffAugmentation""ActivationandOperationoftheTechnicalSupportCenter""ActivationandOperationoftheOperationalSupportCenter""ActivationandOperationoftheEmergencyOperationsFacility""ConductofEvacuations/Assembly""Off-siteNotificationsandProtectiveActionRecommendations""Off-siteDoseCalculations""Off-siteRadiologicalMonitoring""CoreDamageAssessment""MaintainingEmergencyPreparedness-RadiologicalEmergencyPlanTraining""MaintainingEmergencyPreparedness-EmergencyExercises,Drills,TestsandEvaluations"/R37 Page12of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTTABLE2HP-200SERIESPROCEDURESHP-200-"HealthPhysicsEmergencyOrganization"HP-201-"EmergencyPersonnelExposureControl"HP-202-"EnvironmentalMonitoringDuringEmergencies"HP-203-"PersonnelAccessControlDuringEmergencies"HP-204-"In-PlantRadiationandContaminationSurveysDuringEmergencies"HP-205-"EmergencyIn-PlantAirSampling"HP-206-"AnalysisofEmergencyIn-PlantAirSamples"HP-207-"MonitoringEvacuatedPersonnelDuringEmergencies"HP-208-"PersonnelDecontaminationDuringEmergencies" Page13of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTATTACHMENT1UNIT1CONTROLROOM/TECHNICALSUPPORTCENTEREMERGENCYKIT(Sheet1of4)NOTEInspectallbatteriesduringJanuaryandJulyinventories.INSTRUMENTS1.PortableDoseRateInstrument(h5R/hr)PassFailModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixA2.PortableCountRate(Frisker)InstrumentModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixA3.PortableCountRate(Frisker)InstrumentModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixA4.DualChannelAnalyzerModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixADOSIMETRYMinimumAs**QuantityFound1.TLD,WholeBody2.TLD,FingerRing3.TLD,Multibadge4.DRD,0-500mR5.DRD,0-5R6.DRD,0-100R***7.ElectronicDosimeterSemi-annual:Semi-annual:Semi-annual:Calib.DueDate:Calib.DueDate:Calib.DueDate:Calib.DueDate:531650501010MajorEquipmentCodes:P=Pass,F=Fail,R=SeeRemarks***AlarmSetpoint:Dose-4.5R;DoseRate10R/hr.
Page14of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTATTACHMENT1UNIT1CONTROLROOM/TECHNICALSUPPORTCENTEREMERGENCYKIT(Sheet2of4)NOTEInspectallbatteriesduringJanuaryandJulyinventories.1.Coveralls2.ClothHoodDRESS-OUTSUPPLIESMinimumQuantity2020As"*Found3.CottonLiners(pr.)4.RubberGloves(pr.)5.SurgicalGloves(pr.)6.RubberShoeCovers(pr.)7.PlasticBooties(pr.)8.T-Cuts(pr.)9.Whirl-Pack10.Tape(2"roll)*MajorEquipmentCodes:P=Pass,F=Fail,R=SeeRemarks20202020202050 Page15of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTATTACHMENT1UNIT1CONTROLROOM/TECHNICALSUPPORTCENTEREMERGENCYKIT(Sheet3of4)NOTEInspectallbatteriesduringJanuaryandJulyinventories.1.SCBAOTHEREQUIPMENTMinimumQuantityAs**Found2.AirSamplerModelNo.:3.SilverZeoliteCartridges4.ParticulateFiltersSerialNo.:Exp.Date:Calib.DueDate:5.Whirl-Packs(labeledAirSampleData)6.Full-FaceRespirator(performvisualinspection,updatecard)7.CharcoalCanisterExp.Date:8.DosimeterCharger9.ContaminationSmearsandEnvelopes/Folders10.RadiationBarrierTape/Rope/Ribbon11.RadiationSignandAssortedInserts12.Step-offPads13.PolyBags(yellow)14.ExtensionCord(HD)15.ExtensionCordAdapter-White16.ExtensionCordAdapter-Red17.PlasticRainsuits18.Batteries-completesetofreplacementbatteries,bothtypeandnumber,availableforallequipmentrequiringbatteries;checkshelflife.19.TelephoneHeadset*MajorEquipmentCodes:P=Pass,F=Fail,R=SeeRemarks16500N/A101020N/A/R37 Page16of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTATTACHMENT1UNIT1CONTROLROOM/TECHNICALSUPPORTCENTEREMERGENCYKIT(Sheet4of4)NOTEInspectallbatteriesduringJanuaryandJulyinventories.DOCUMENTS,PROCEDURES,LOGS1.PSLEmergencyPlan(checkforcurrentrevision)2.EPIPs(fullset)(checkforcurrentrevisions)3.EmergencyResponseDirectory(checkforcurrentrevision)4.HP-90(checkforcurrentrevision)5.HP-200Series(fullset)(checkforcurrentrevisions)6.HP-206:Attachments1,2,3andFormsHP-206.1andHP-206.2(10copieseach)(checkforcurrentrevision)7.COP-06.06(checkforcurrentrevision)8.COP-06.11,"EstablishingRemoteLaboratoryforAnalysesofAccidentSamples"(checkforcurrentrevision)9.RadiationExposureSummaryReport10.ControlRoomRadSurveyMaps(10copies)11.LaminatedFloorPlanMapswithIndexforRadSurvey(fullset)12.FieldMonitoringMaps*MajorEquipmentCodes:P=Pass,F=Fail,R=SeeRemarksAvail.Unavail./R37Remarks:Inventoriedby:Date:Reviewedby:Date:
Page17of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTATTACHMENT2UNIT2CONTROLROOMEMERGENCYKIT(Sheet1of4)NOTEInspectallbatteriesduringJanuaryandJulyinventories.INSTRUMENTS1.PortableDoseRateInstrument(a5R/hr)PassFailModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixA*2.PortableCountRate(Frisker)InstrumentModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixA3.PortableCountRate(Frisker)InstrumentModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixA4.DualChannelAnalyzerModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixADOSIMETRYMinimumQuantityAs*Found1.TLD,WholeBody2.TLD,FingerRing3.TLD,Multibadge4.DRD,0-500mR5.DRD,0-5R6.DRD,0-100R7.ElectronicDosimeterSemi-annual:Semi-annual:Semi-annual:Calib.DueDate:Calib.DueDate:Calib.DueDate:Calib.DueDate:101250101010*MajorEquipmentCodes:P=Pass,F=Fail,R=SeeRemarks***AlarmSetpoints:Dose-4.5R;DoseRate10R/hr.
Page18of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTATTACHMENT2UNIT2CONTROLROOMEMERGENCYKIT(Sheet2of4)NOTEInspectallbatteriesduringJanuaryandJulyinventories.1~CoverallsDRESS-OUTSUPPLIESMinimumQuantity10As**Found2.ClothHood3.CottonLiners(pr.)4.RubberGloves(pr.)5.SurgicalGloves(pr.)6.RubberShoeCovers(pr.)7.PlasticBooties(pr.)8.T-Cuts(pr.)9.Whirl-Pack10.Tape(2"roll)*MajorEquipmentCodes:P=Pass,F=Fail,R=SeeRemarks1010101010101050 Page19of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTATTACHMENT2UNIT2CONTROLROOMEMERGENCYKIT(Sheet3of4)NOTEInspectallbatteriesduringJanuaryandJulyinventories.1.SCBAOTHEREQUIPMENTMinimumQuantityAsFound2.AirSamplerModelNo.:3.SilverZeoliteCartridges4.ParticulateFiltersSerialNo.:Exp.Date:Calib.DueDate:5.Whirl-Packs(labeledAirSampleData)6Full-FaceRespirator(performvisualinspection,updatecard)7CharcoalCanisterExp.Date:8DosimeterCharger9ContaminationSmearsandEnvelopes/Folders10.RadiationBarrierTape/Rope/Ribbon11.RadiationSignandAssortedInserts12.Step-offPads13.PolyBags(yellow)14.ExtensionCord(HD)15.ExtensionCordAdapter-White16.ExtensionCordAdapter-Red17.PlasticRainsuits18.Batteries-completesetofreplacementbatteries,bothtypeandnumber,availableforallequipmentrequiringbatteries;checkshelflife*MajorEquipmentCodes:P=Pass,F=Fail,R=SeeRemarks16500N/A1010N/A10N/A/R37 Page20of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTATTACHMENT2UNIT2CONTROLROOMEMERGENCYKIT(Sheet4of4)NOTEInspectallbatteriesduringJanuaryandJulyinventories.DOCUMENTS,PROCEDURES,LOGS1.PSLEmergencyPlan(checkforcurrentrevision)2.EPIPs(fullset)(checkforcurrentrevisions)3.EmergencyResponseDirectory(checkforcurrentrevision)4.HP-200Series(fullset)(checkforcurrentrevisions)5.HP-206:Attachments1,2,3andFormsHP-206.1andHP-206.2(10copieseach)(checkforcurrentrevision)6.RadiationExposureSummaryReport7.ControlRoomRadSurveyMaps(10copies)*MajorEquipmentCodes:P=Pass,F=Fail,R=SeeRemarksRemarks:Avail.Unavail./R37Inventoriedby:Date:Reviewedby:Date:
Page21of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTATTACHMENT3OPERATIONALSUPPORTCENTEREMERGENCYKIT(Sheet1of4)NOTEInspectallbatteriesduringJanuaryandJulyinventories.INSTRUMENTS1.PortableDoseRateInstrument(25R/hr)PassFailModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixA2.PortableDoseRateinstrument(25R/hr)ModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixA3.PortableDoseRateInstrument(a5R/hr)ModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaamrdancewithAppendixA4.PortableCountRate(Fnsker)InstrumentModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixA5.PortableCountRate(Frisker)instrumentModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixA6.PortableCountRate(Frisker)InstrumentModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckInaccordancewithAppendixA7.PortableCountRate(Frisker)InstrumentModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixA8.DualChannelAnalyzerModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixA9.SealerandDetectorModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixAMajorEquipmentCodes:P=Pass,F=Fail,R=SeeRemarks Page22of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTATTACHMENT3OPERATIONALSUPPORTCENTEREMERGENCYKIT(Sheet2of4)NOTEInspectallbatteriesduringJanuaryandJulyinventories.DOSIMETRY1.TLD,WholeBodySemi-annual:2.TLD,FingerRingSemi-annual:3.TLD,MultibadgeSemi-annual:4.DRD,0-500mRCalib.DueDate:MinimumAs"*QuantityFound462250405.DRD,0-5R6.DRD,0-100R1.Coveralls2.ClothHoodCalib.DueDate:'alib.DueDate:DRESS-OUTSUPPLIES201050503.CottonLiners(pr.)4.RubberGloves(pr.)5.SurgicalGloves(pr.)6.RubberShoeCovers(pr.)7.PlasticBooties(pr.)8.T-Cuts(pr.)9.Whirl-Pack10.Tape(2"roll)11.ShavingCream(can)12.DisposableRazorsOTHEREQUIPMENT1.SCBA505050505050100102.AirSamplerModelNo.:3.SilverZeoliteCartridges4.ParticulateFiltersSerialNo.:Exp.Date:Calib.DueDate:20205.Whirl-Packs(labeledAirSampleData)6.Full-FaceRespirator(performvisualinspection,updatecard)7.CharcoalCanisterExp.Date:8.DosimeterCharger(electric)MajorEquipmentCodes:P=Pass,F=Fail,R=SeeRemarks201224 Page23of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTATTACHMENT3OPERATIONALSUPPORTCENTEREMERGENCYKIT(Sheet3of4)NOTEInspectallbatteriesduringJanuaryandJulyinventories.OTHEREQUIPMENT(continued)9.DosimeterCharger(battery)10.ContaminationSmearsandEnvelopes/Folders11.RadiationBarrierTape/Rope/Ribbon12.RadiationSignandAssortedInserts13.Step-offPads14.PolyBags(yellow)15.PortableFluorescentLights16.Flashlights17.Rope(manila)18.InsectRepellent(spraycan)19.DecontaminationAgent20.BullHorn21.PlasticRainsuits22.Clipboards(regular)23.LinedTablets24.NotePads25.Felt-TipPens(black)26.InkPens(black)27.Pencils28.Scissors29.Calculator30.Staplerwithstaples31.BoltCutters32.Batteries-Completesetofreplacementbatteries,bothtypeandnumber,availableforallequipmentrequiringbatteries;checkshelflife.*MajorEquipmentCodes:P=Pass,F=Fail,R=SeeRemarksMinimumQuantity1500N/A20205024N/A10501010242424N/AAs~*Found Page24of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTATTACHMENT3OPERATIONALSUPPORTCENTEREMERGENCYKIT(Sheet4of4)NOTEInspectallbatteriesduringJanuaryandJulyinventories.DOCUMENTS,PROCEDURES,LOGS1.EPIPs(fullset)(checkforcurrentrevision)2.EmergencyResponseDirectory(5copies)(checkforcurrentrevision)3.HPP-70(checkforcurrentrevision)4.HP-90(checkforcurrentrevision)5.HP-200(fullset)(checkforcurrentrevision)6.COP-06.06(checkforcurrentrevision)7.COP-06.11,"EstablishingRemoteLaboratoryforAnalysesofAccidentSamples"(checkforcurrentrevision)8.RadiationExposureSummaryReport9.HPBlankSurveyForms(Unit1andUnit2)10.FieldMonitoringMap11.AssemblyAreaKitEmergencyResponseDirectory(1copy)(checkforcurrentrevision)HP-207(checkforcurrentrevision)HP-208(checkforcurrentrevision)12.DeconLogNotebookincluding:FormHP207.1(25copies)(checkforcurrentrevision)FormHPP-70.1(25copies)(checkforcurrentrevision)COMMUNICATIONSTEST1.VideolinkCheckPerformcheckinaccordancewithAppendixB*MajorEquipmentCodes:P=Pass,F=Fail,R=SeeRemarksAvail.PassUnavail.FailRemarks:Inventoriedby:Date:Reviewedby:Date:
Page25of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTATTACHMENT4SITEASSEMBLYSTATIONEMERGENCYKIT(Sheet1of3)NOTEInspectallbatteriesduringJanuaryandJulyinventories.INSTRUMENTS*1.PortableCountRate(Frisker)Instrument(Decon)ModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixAPassFail*2.PortableCountRate(Frisker)Instrument(FjeldTeam)ModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixA*3.PortableCountRate(Frisker)Instrument(FieldTeam)ModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixA4.PortableCountRate(Frisker)Instrument(FieldTeam)ModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixA*5.PortableCountRate(Frisker)Instrument(FieldTeam)ModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixA*MajorEquipmentCodes:P=Pass,F=Fail,R=SeeRemarks Page26of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTATTACHMENT4SITEASSEMBLYSTATIONEMERGENCYKIT(Sheet2of3)NOTEInspectallbatteriesduringJanuaryandJulyinventories.1.Coveralls2.ClothHoodDRESS-OUTSUPPLIESMinimumAs**QuantityFound10103.CottonLiners(pr.)4.RubberGloves(pr.)5.SurgicalGloves(pr.)6.RubberShoeCovers(pr.)7.PlasticBooties(pr.)8.T-Cuts(pr.)9.Whirl-Pack10.Tape(2"roll)OTHEREQUIPMENT1.PaperPCs2.RadiationBarrier(Tape/Rope/Ribbon)3.RadiationSignandAssortedInserts4.Step-offPads5.PolyBags(yellow)6.5GallonJugofWater7.WaterlessHandCleaner(can)8.HandRags9.Towels10.ShavingCream(can)11.DisposableRazors12.FirstAidKit1010101010105010N/AIO5050*MajorEquipmentCodes:P=Pass,F=Fail,R=SeeRemarks Page27of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTATTACHMENT4SITEASSEMBLYSTATIONEMERGENCYKIT(Sheet3of3)NOTEInspectallbatteriesduringJanuaryandJulyinventories.DOCUMENTS,PROCEDURES,LOGS1~EmergencyResponseDirectory(checkforcurrentrevision)2.HP-200Series(fullset)(checkforcurrentrevision)3.Notebook4.DeconLogClipboardwith:FormHP207.1(25copies)(checkforcurrentrevision5.DeconLogClipboardwith:Avail.Unavail~FormHPP-70.1(25copies)(checkforcurrentrevision)COMMUNICATIONSTEST1.WallPhonePerformcommunicationstestinaccordancewithAppendixB*MajorEquipmentCodes:P=Pass,F=Fail,R=SeeRemarksRemarks:PassFailInventoriedby:Date:Reviewedby:Date:
Page28of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTATTACHMENT5SITEASSEMBLYSTATION-FIELDMONITORINGTEAMEMERGENCYKIT(Sheet1of2)NOTEInspectallbatteriesduringJanuaryandJulyinventories.INSTRUMENTS1.PortableDoseRateInstrument(h5R/hr)ModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixAPassFail2.DualChannelAnalyzerModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixADOSIMETRYMinimumAs**QuantityFound1.TLD,WholeBodySemi-annual:2.EPD***3.DRD,0-5ROTHEREQUIPMENT1.AirSampler(autobattery-powered)Calib.DueDate:Calib.DueDate:ModelNo.:SerialNo.:Calib.DueDate:2.SilverZeoliteCartridges3.ParticulateFiltersExp.Date:4.Whirl-Packs(labeled"AirSampleData")5.SurgicalGloves(pr.)6.PortableRadio7.PowerCordwithCigarette-LighterPlug8.DCPowerReceptaclewithBatteryClips9.MicrophonewithCable10.Magnetic-MountAntenna11.FullFaceRespirator(performvisualinspection,updatecard)12.CharcoalCanisterExp.Date:*MajorEquipmentCodes:P=Pass,F=Fail,R=SeeRemarks*"*Alarmsetpoints:Dose-4.5R,DoseRate10R/hr.
Page29of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTATTACHMENT5SITEASSEMBLYSTATION-FIELDMONITORINGTEAMEMERGENCYKIT(Sheet2of2)NOTEInspectallbatteriesduringJanuaryandJulyinventories.OTHEREQUIPMENT(continued)13.Stopwatch14.Calculator15.DosimeterCharger16.Tweezers17.Flashlight18.Batteries-Completesetofreplacementbatteries,bothtypeandnumber,availableforallequipmentrequiringbatteries;checkshelflife.DOCUMENTS,PROCEDURES,LOGS1.EmergencyResponseDirectory(checkforcurrentrevision)2HP-202(checkforcurrentrevision)3(Form)Table1ofHP-202(2copies)(checkforcurrentrevision)4FormHP-202.1(6copies)(checkforcurrentrevision)5FieldMonitoringLog6.FieldMonitoringMapsMinimumQuantityN/AAvail.As*'oundUnavail.*MajorEquipmentCodes:P=Pass,F=Fail,R=SeeRemarksRemarks:Inventoriedby:Reviewedby:Date:Date:
Page30of56ST.LUCIEPLANT.HEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTATTACHMENT6EMERGENCYOPERATIONSFACILITYEMERGENCYKIT(Sheet1of3)NOTEInspectallbatteriesduringJanuaryandJulyinventories.INSTRUMENTS1.PortableDoseRateInstrument(>5R/hr)PassFailModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixA*2.PortableCountRate(Frisker)InstrumentModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixA*3.PortableCountRate(Frisker)InstrumentModelNo.:SerialNo.:Calib.DueDatePerformoperabilitycheckinaccordancewithAppendixADOSIMETRY1.TLD,WholeBodySemi-annual:2.DRD,0-500mRCalib.DueDate:3.DRD,0-5RCalib.DueDate:DRESS-OUTSUPPLIES1.Coveralls2.ClothHood3.CottonLiners(pr.)4.RubberGloves(pr.)5.SurgicalGloves(pr.)6.RubberShoeCovers(pr.)7.PlasticBooties(pr.)8.T-Cuts(pr.)9.Whirl-Pack10.Tape(2"roll)*MajorEquipmentCodes:P=Pass,F=Fail,R=SeeRemarksMinimumAs**QuantityFound10202020202020202050 Page31of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTATTACHMENT6EMERGENCYOPERATIONSFACILITYEMERGENCYKIT(Sheet2of3)NOTEInspectallbatteriesduringJanuaryandJulyinventories.OTHEREQUIPMENT1.FullFaceRespirator(performvisualinspection,updatecard)2.CharcoalCanisterExp.Date:3.DosimeterCharger(electric)MinimumQuantity12As"Found4.DosimeterCharger(battery)5.SilverZeoliteCartridgesExp.Date:506.ContaminationSmearsandEnvelopes/Folders7.RadiationBarrier(Tape/Rope/Ribbon)8.RadiationSignandAssortedInserts9.Step-offPads10.PolyBags(yellow)11.PlasticRainsuits12.Batteries-Completesetofreplacementbatteries,bothtypeandnumber,availableforallequipmentrequiringbatteries;checkshelflife.DOCUMENTS,PROCEDURES,LOGS1.PSLEmergencyPlan(checkforcurrentrevision)2.EPIPs(fullset)(checkforcurrentrevision)3.EmergencyResponseDirectory(checkforcurrentrevision)4.FloridaPower8LightCompanySt.LuciePlantRecoveryPlan5.HP-90(checkforcurrentrevision)6.HP-200Series(fullset)(checkforcurrentrevision)7.COP-06.06(checkforcurrentrevision)500N/A10101020N/AAvail.Unavail.8.COP-06.11,"EstablishingRemoteLaboratoryforAnalysesofAccidentSamples"(checkforcurrentrevision)COMMUNICATIONSTEST1.NRCEmergencyNotificationSystem(ENS)PerformcommunicationstestinaccordancewithAppendixB2.NRCHealthPhysicsNetwork(HPN)PerformcommunicationstestinaccordancewithAppendixB3.NRCReactorSafetyCounterpartLink(RSCL)PerformcommunicationstestinaccordancewithAppendixB.*MajorEquipmentCodes:P=Pass,F=Fail,R=SeeRemarksPassFail Page32of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTATTACHMENT6EMERGENCYOPERATIONSFACILITYEMERGENCYKIT(Sheet3of3)NOTEInspectallbatteriesduringJanuaryandJulyinventories.COMMUNICATIONSTEST-EMERGENCYOPERATIONSFACILITY(EOF)(continued)4.NRCProtectiveMeasuresCounterpartLink(PMCL)PerformcommunicationstestinaccordancewithAppendixB.5.NRCManagementCounterpartLink(MCL)PerformcommunicationstestinaccordancewithAppendixB.6.NRCLocalAreaNetwork(LAN)PerformcommunicationstestinaccordancewithAppendixB7.LocalGovernmentRadio(LGR)Channel2(39.18MHz)PerformcommunicationstestinaccordancewithAppendixB;0Unit1,0Unit2,0TSC(AII3oktopass)8.LocalGovernmentRadio(LGR)Channel1(39.10MHz)PerformcommunicationstestinaccordancewithAppendixB;0Unit1,0Unit2,0TSC(AII3oktopass)9.SpectraRadio,HPOffsiteChannelPerformcommunicationstestinaccordancewithAppendixB10.StateWarningPoint(SWP)HotRingDownPhone(HRD)PerformcommunicationstestinaccordancewithAppendixB11.VideolinkcheckPerformcheckinaccordancewithAppendixB12.Testfaxmachinesinrooms102,108and130(sendfaxtoEPatext.7514).SendusingformsimilartoAppendixC.13.Testcopymachinesinrooms102and131.RuncopyusingformsimilartoAppendixD.MajorEquipmentCodes:P=Pass,F=Fail,R=SeeRemarksRemarks:PassFailInventoriedby:Date:Reviewedby:Date:
Page33of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37'MERGENCYEQUIPMENTATTACHMENT7HOSPITALEMERGENCYKIT(Sheet1of2)NOTEInspectallbatteriesduringJanuaryandJulyinventories.INSTRUMENTS1.PortableDoseRateInstrument(25R/hr)PassFailModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixA2.PortableCountRate(Frisker)InstrumentModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixA3.PortableCountRate(Frisker)InstrumentModelNo.:SerialNo.:Calib.DueDate:PerformoperabilitycheckinaccordancewithAppendixADOSIMETRY*1.TLD,WholeBodySemi-annual:MinimumAs'*QuantityFound122.DRD,0-20R3.DRD,0-500mROTHEREQUIPMENTCalib.DueDate:Calib.DueDate:121.DosimeterCharger2.ContaminationSmearsandEnvelopes/Folders3.RadiationBarrierTape/Rope/Ribbon4.RadiationSignandAssortedInserts5.Step-offPads6.PolyBags(yellow)7.Herculite(maybeprecut)8.DecontaminationTableandAccessories9.Tape(2"roll)10.RadioactiveMaterialTagsMajorEquipmentCodes:P=Pass,F=Fail,R=SeeRemarks500N/A1020N/A25 Page34of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTATTACHMENT7HOSPITALEMERGENCYKIT(Sheet2of2)NOTEInspectallbatteriesduringJanuaryandJulyinventories.OTHEREQUIPMENT(continued)11.LinedTablets12.NotePads13.InkPens(black)MinimumAs**QuantityFound1214.Batteries-Completesetofreplacementbatteries,bothN/Atypeandnumber,availableforallequipmentrequiringbatteries;checkshelflife.DOCUMENTS,PROCEDURES,LOGS1.EmergencyResponseDirectory(checkforcurrentrevision)2.HPP-70(checkforcurrentrevision)3.HPP-101(checkforcurrentrevision)4.HP-207(checkforcurrentrevision)5.HP-208(checkforcurrentrevision)6.FormHPP-101~1(5copies)(checkforcurrentrevision)7.FormHPP-70.1(5copies)(checkforcurrentrevision)*MajorEquipmentCodes:P=Pass,F=Fail,R=SeeRemarksRemarks:Avail.Unavail.Inventoriedby:Date:Reviewedby:Date:
Page35of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTAPPENDIXAOPERABILITYINSTRUCTIONS(Sheet1of5)1.PortableDoseRateInstrument-Checkcalibrationsticker,batterytestandresponsetosuppliedchecksource.NOTEKitchecksourcesshouldnotbestorednearthekitTLDs.2.PortableCountRateInstrument-Checkcalibrationsticker,batterytest(unpluglinecord)andresponsetosuppliedchecksource.3.BatteryandOperationalChecksoftheLudlumModel2218.NOTEShoulditbenecessarytouseChannel2,itemscontainedwithinparenthesesaresettingstobeusedforChannel2.AlayoutoftheLudlumModel2218isprovidedinFigure1tothisAppendix.VerifythattheRECYCLEknobisOFF.Theknobislabeledandlocatedontherearpaneloftheinstrument.3.1Checkthebatteryasfollows:NOTEIfaninstrumentfailsthebatterycheck,itcanbeusedonlyifitisconnectedtoACpowerandthereforeshouldbereplacedwithaninstrumentcapableofpassingthisoperabilitycheck.1.TurnthePOWERknobto"BAT".2.UnplugtheAClinecord.3.DepresstheBATtestbutton.
Page36of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTAPPENDIXAOPERABILITYINSTRUCTIONS(Sheet2of5)3.(continued)3.1(continued)4.ObservetheconditionbelowtheRATESCALE.5.IfbatteryconditionisnotwithintheacceptableBATTESTrange,plugintheAClinecordandturnthePOWERknobtoCHARGE.Attachalabeltotheinstrumentstating"Instrumentischarging,startedchargeatAM/PMon196.Ifthebatteryconditionisacceptable,thencontinuewiththestepsbelow.3.2SettheSTABILIZERtoggleswitchtoOFF.NOTESteps3.3through3.15.4areinitiallyperformedonChannel1.3.3Chi(Ch2),settheADD-OFF-SUBTRACTknobtoADD.3.4Ch2(Ch1),settheADD-OFF-SUBTRACTknobtoOFF3.5Ch1andCh2,settheON-BYPASStoggleswitchtoBYPASS.3.6Ch1(Ch2),settheWINDOWandtheTHRESHOLDdialsIAW(inaccordancewith)settingsonthesideofthe2218cabinet.3.7SettheunusedChannel'sWINDOWandTHRESHOLDdialsto10.0.3.8Ch1(Ch2),settheIN-OUTtoggleswitchtoIN.3.9Ch2(Ch1),settheIN-OUTtoggleswitchtoOUT.3.10SettheMINUTESknobtoX1.3.11SettheLIVE-CLOCKtoggleswitchtoLIVE.
Page37of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTAPPENDIXAOPERABILITYINSTRUCTIONS(Sheet3of5)3.(continued)3.12SettheF-S(Fast-Slow)toggleswitchtoS.3.13SettheCh1-Ch2-SealerknobtoSCALER.3.14SettheMINUTESthumbwheelto01~3.15Performasourcecheckasfollows:1.PlacetheBa-133checksourceintheshieldunderthedetector.2.DepresstheCOUNT-RESETbuttontostartcounting.3.Whencountingstops,comparethedisplayedcountswiththeacceptancerangethatislocatedonthesideoftheinstrument.4.Ifthedisplayedcountsarewithintheacceptancerangethengotostep3.17.Ifthedisplayedcountsarenotwithintheacceptancerangethengotostep3.16.3.16Highvoltage(HV)adjustmentsareperformedasfollows:1.SettheMINUTESknobtoEXT.2.PlacetheBa-133checksourceintheshieldunderthedetector.3.DepresstheCOUNT-RESETbuttontostartcounting.4.ObservetheCOUNTS/MINUTE(CountRateMeter)scalewhilemakingsmalladjustmentsinvoltagetoobtainthemaximumcountrateachievable.5.IncreaseordecreasethevoltagewiththeHV(HighVoltage)dial~6.SettheMINUTESknobtoX1.7.DepresstheCOUNT-RESETbuttontostartcounting.
Page38of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTAPPENDIXAOPERABILITYINSTRuCTIONS(Sheet4of5)3.(continued)3.16(continued)8.Whencountingstops,comparethedisplayedcountswiththeacceptancerangethatislocatedonthesideoftheinstrument.9.Ifthedisplayedcountsarewithintheacceptancerangethengotostep3.17.Ifthedisplayedcountsarenotwithintheacceptancerangethenrepeatsteps3.3through3.15.4usingchannel2.3.17Iftheinstrumentsuccessfullycompletedtheoperationalresponsecheck,recordtheresultsontheappropriateAttachment.3.18Iftheinstrumentdidnotsuccessfullycompletetheoperationalcheck,usingchannel2:1.TagtheinstrumentOUTOFSERVICE,givethereason.2.RecordtheresultsintheappropriateAttachment.3.GivethereasonforfailureintheRemarkssection.3.19Iftheinstrumentsuccessfullycompletedtheoperationalresponsecheckusingchannel2,recordtheresultsontheappropriateAttachmentandlabeltheinstrument"usechannel2"~3.20TurnthepowerknobtoCHARGE.4.SealerandDetector-checkthecalibrationstickerandresponsetosuppliedchecksource.Thisisaresponsecheckonly;usethesuppliedkitchecksourceusedfordoserateinstruments.
Page39of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENT8xQ~5$~8~QooOQo~-I8~o5yC3oyQ8866528CoAPPENDIXAOPERABILITYINSTRUCTIONS(Sheet5of5)CODOVUJKDC9Ur~0:oIO00flIh2~~V)~~X00IIII~>5LOCCUJ'CiV)P00dpQl~~UJwDeDEOolvZr"COIu.oPgO~rV)~o<cHi~O~O~~~0-<$IIIc0CrVL00CINCIcPSgI-X85euRooobrOQIg'OI~y+osI!o!i<aPOhC.>4Oo~5i5IOIII00XDUjAOLig>C)0)oEO)~~QI-<CG)Q)Vk Page40of56ST.LUCIEPLANT,HEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTAPPENDIXBINSTRUCTIONSFORTESTINGEMERGENCYCOMMUNICATIONSEQUIPMENT(Sheet1of15)I.ControlRoomsA.Unit1ControlRoomemergencycommunicationsequipmentistestedinaccordancewithplantOperatingProcedure1-0010125,"ScheduleofPeriodicTests,ChecksandCalibrations."B.Unit2ControlRoomemergencycommunicationsequipmentistestedinaccordancewithplantOperatingProcedure2-0010125,"ScheduleofPeriodicTests,ChecksandCalibrations."II.TechnicalSupportCenter(TSC)A.TechnicalSupportCenteremergencycommunicationsequipmentistestedinaccordancewithEPIP-13,"MaintainingEmergencyPreparedness-EmergencyExercises,Drills,TestsandEvaluations".III.OperationalSupportCenter(OSC)A."Videolink"-the"Videolink"isaclosedcircuitaudio/visualcommunicationslinkoriginatingintheTSCwithfeedstotheOSCandtheEmergencyOperationsFacility.1.InstructionsforTestinga.ContactsomeonetogototheTSCtoassistwiththetestofthe"Videolink",ifnotpreviouslyarranged.b.TurnonthetelevisionsetsinbothRooms2200and2300.c.Setthechannelselectortochannel9andadjustvolume.d.RequestthepersonintheTSCtoprovideatestbroadcast.e.Operabilityisverifiedifboththevideopictureandaudiooutputarereceivedonthetelevisionsetsinbothrooms.Thepicturemustbeclearandtheaudiofreefromstatic./R37/R37 Page41of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTAPPENDIXBINSTRUCTIONSFORTESTINGEMERGENCYCOMMUNICATIONSEQUIPMENT(Sheet2of15)III.(continued)A.(continued)1~(continued)f.Recordoperabilitystatusontheinventoryform(Attachment3)~g.Ifthe"Videolink"isinoperable(oneorbothtelevisionsets),notifyEmergencyPlanning.h.Followingcompletionofthetests,turnoffthetelevisionsetsinrooms2200and2300.IV.EmergencyOperationsFacility(EOF)TestingtheNRCEmergencyTelecommunicationsSystem(FTS2000).A.EmergencyNotificationSystem(ENS)1.Phonenumber:(700)821-00052.3extensionsa.Room101,NRCTableb.Room101,RecoveryManagerTablec.Room114 Page42of56ST.LUCIEPLANT,HEALTHPHYSICSOPERATINGPROCEDURE,NO.HP-90,REVISION37EMERGENCYEQUIPMENTAPPENDIXBINSTRUCTIONSFORTESTINGEMERGENCYCOMMUNICATIONSEQUIPMENT(Sheet3of15)IV.(continued)A.(continued)3.Testa.Checkallthreephonesfordialtonebyliftingthehandsetofthetelephoneandlisteningforadialtone.b.Usingoneofthephoneextensions,calltheNRCOperationCenter(NRCOC)byliftingthehandsetanddialingthefirstnumberlistedonthestickerlocatedonthetelephonecradle.Noaccesscodeisnecessary,justdialalltendigitsofthenumber.Ifthemainnumberisbusy,dialthebackupnumber.Alternatenumbersuntilcontactismade.c.AftertheNRCOCDutyOfficeranswers,informhimasfollows:"ThisistheSt.LucieEmergencyOperationsFacility.IamconductingacheckoftheENS,howdoyoureceiveme?"AsktheNRCOCDutyOfficerifhewishestocallback,ifsogivehimthetelephonenumberandawaitthecall.d.Thetestispassedif(1)allphoneshavedialtone,(2)thelinkisoperable,and(3)theNRCOCissuccessfullycontacted.e.Recordthetestresultontheinventoryform(Attachment6).f.Ifthetestisafailure,seeinformationunderTroubleNotification.B.HealthPhysicsNetwork(HPN)Phonenumber:(700)821-00032.3extensionsa.Room101,NRCTableb.Room103(2)3.GotostepF,TestProcedure Page43of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTAPPENDIXBINSTRUCTIONSFORTESTINGEMERGENCYCOMMUNICATIONSEQUIPMENT(Sheet4of15)IV.(continued)C.ReactorSafetyCounterpartLink(RSCL)1.Phonenumber:(700)821-00082.2extensionsa.Room101,NRCTableb.Room1143.GotostepF,TestProcedureD.ProtectiveMeasuresCounterpartLink(PMCL)1.Phonenumber:(700)821-00062.2extensionsa.Room101,NRCTableb.Room1143.GotostepF,TestProcedure.E.ManagementCounterpartLink(MCL)1.Phonenumber:(700)821-00042.2extensionsa.Room101,NRCTableb.Room1143.GotostepF,TestProcedure
Page44of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTAPPENDIXBINSTRUCTIONSFORTESTINGEMERGENCYCOMMUNICATIONSEQUIPMENT(Sheet5of15)IV.(continued)F.TestProcedureforHPN,RSCL,PMCLandMCL.1.Foreachcommunicationlink,dothefollowing:a.Checkallextensionsfordialtonebyliftingthehandsetofthetelephoneandlisteningforadialtone.b.ChecklinkoperabilitybyusingthephonesontheNRCTableinRoom101.Eachlinkmustbeabletocall-outandreceiveacalltopass.Usethefollowingcallscheme:HPN:Dial700-821-0008RSCL:Dial700-821-0006PMCL:Dial700-821-0004MCL:Dial700-821-0003c.Thetestispassedif(1)allphoneshavedialtoneand(2)thelinkisoperable.d.Recordthetestresultontheinventoryform(Attachment6)foreachcommunicationlink.e.Ifthetestisafailure,seeinformationunderTroubleNotification.G.LocalAreaNetwork(LAN)1.Phonenumber:(700)821-0007.2.1extensiona.Room1143.Testa.Checkthetelephonelinebyplugginginatelephone,liftingthehandsetandlisteningforadialtone.
Page45of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTAPPENDIXBINSTRUCTIONSFORTESTINGEMERGENCYCOMMUNICATIONSEQUIPMENT(Sheet6of15)IV.(continued)H.TroubleNotification1.IfanyaspectoftheEmergencyTelecommunicationsSystemisinoperablenotifytheNRCOperationsCenterinRockville,Marylandbyusingacommercialtelephoneanddialingoneofthefollowingnumbers:(301)951-0550(301)816-51002.Providethefollowinginformation(perIN86-97):a.Nameofcontact-DonnaCalabrese,RickWalkerorSteveKnappb.Phonenumberofcontact-DonnaCalabrese(561)467-7185RickWalker(561)467-7170SteveKnapp(561)467-7246c.Locationofcontact-FPL/PSL6501S.OceanJensenBeach,Florida34957d.Anyotherinformationthatwouldexpediterepair,ifknownorasrequested.3.NotifyDonnaCalabrese,RickWalkerorSteveKnapp.
Page46of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTAPPENDIXBINSTRUCTIONSFORTESTINGEMERGENCYCOMMUNICATIONSEQUIPMENT(Sheet7of15)IV.(continued)I.TheLocalGovernmentRadio(LGR)hastwolowbandradiofrequenciesutilizedbySt.LucieCounty,MartinCounty,theSt.LuciePlantControlRooms,theTechnicalSupportCenterandtheEmergencyOperationsFacility.ThisisabackuptotheStateHotRingDownPhoneCircuit.TherearetwoMotorolaCommandSeriesradios,onesettotheprimarychannel,F2(39.180MHz,Statechannel1)andtheothersettothesecondarychannel,F1(39.100MHz,Statechannel2).ThetestincludestestingbothchannelswiththeUnit1ControlRoom,theUnit2ControlRoom,andtheTechnicalSupportCenter.CAUTIONTosafeguardagainstpotentialdamageresultingfromlightningstrikingtheEOF,powercordsfortheLGRandHPOff-SiteChannelRadiosareleftdisconnectedwhennotinuse.ThephonecablestoeachradioareNOTtobedisconnected.1.PoweringUptheRadio:a.Plugthepowercordfromeachradiounitintothewalloutletsbehindthetable.TheF2lightwillilluminate.b.Ensurethephonecablefromeachradioispluggedintooneofthe3phonejacksonthewallbehindthetable.Allthejacksarewiredforall3radios(LGRF1,LGRF2,andDepartmentofHealth(DOH)).(TheDOHradioisNOTincludedinthistest)~
Page47of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTAPPENDIXBINSTRUCTIONSFORTESTINGEMERGENCYCOMMUNICATIONSEQUIPMENT(Sheet8of15)IV.(continued)I~(continued)NOTEPriortocommencingthetestingwiththeControlRooms,contactsomeoneattheplanttogototheTSCtoassistwithtestingoftheTSCradios.2.InstructionsforTesting:ControlRoomsa.CalloneofthePlantSt.LucieControlRoomsandaskthemtostandbyfortestingtheLGR.b.BeginbytestingtheradiowhichissettochannelF2,thechannelnormallymonitoredbytheControlRooms.c.Theradiomaybeoperatedeitherbydepressingthe"transmit"buttonontheconsoleorbyremovingthehandsetanddepressingthe"push-to-talk"barinthehandset.The"xmit"lightislitduringtransmission.Transmitthefollowing:"St.LucieUnit1or2(whicheveryouarrangedtotestwith),thisisSt.LucieEOF,comeinplease,over."FollowingacknowledgementfromtheControlRoom,continuewith:"St.LuciePlant,thisistheSt.LucieEOFconductingacommunicationstest,howdoyouread,over?"IftheControlRoomconfirmscleartransmissionandyoucanconfirmclearreceptionoftheresponse,thenhavetheradioswitchedtochannelF1,followingterminationofthemessage,andstandbyforatest.Endthetransmissionwith:"ThisisSt.LucieEOF,out."Iftransmissionisunsuccessful,calltheControlRoomandhavetheradioswitchedtochannelF1.Proceedtothenextstep.
Page48of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTAPPENDIXBINSTRUCTIONSFORTESTINGEMERGENCYCOMMUNICATIONSEQUIPMENT(Sheet9of15)IV.(continued)I.(continued)2.(continued)d.NowtesttheradiowhichissettochannelF1.Transmitthefollowing:"St.LuciePlant,thisisSt.LucieEOF,comeinplease,over."FollowingacknowledgementfromtheControlRoom,continuewith:"St.LuciePlant,thisistheSt.LucieEOFconductingacommunicationstest,howdoyouread,over?"IftheControlRoomconfirmsacleartransmissionandyoucanconfirmclearreceptionoftheresponse,thenendthetransmissionwith:"Thisconcludesthiscommunicationstest,resettheradiotochannelF2,thisisSt.LucieEOF,KNGR874overandout."Iftransmissionisunsuccessful,calltheControlRoomandhavetheradioresettochannelF2.Proceedtothenextstep.e.Recordoperabilitystatusontheinventoryform(Attachment6).f.Ifoneorbothchannelsofthesystemis/areinoperable,thennotifyanEmergencyPreparednessCoordinatorortheEmergencyPreparednessSupervisor.g.RepeatthetestprocedureinStepsc-fabovewiththeotherControlRoom.TechnicalSupportCentera.ContactsomeoneattheplanttogototheTSCtoassistwiththeradiotest,ifnotpreviouslyarranged.b.BeginbytestingtheradiowhichissettochannelF2,thechanneltheradiointheTSCisseton.
Page49of56ST.LUCIEPLANTHEALTHPHYSIGSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTAPPENDIXBINSTRUCTIONSFORTESTINGEMERGENCYCOMMUNICATIONSEQUIPMENT(Sheet10of15)IV.(continued)I.(continued)2.(continued)c.Transmitthefollowing:"St.LucieTSC,thisisSt.LucieEOF,comeinplease,over."FollowingacknowledgementfromtheTSC,continuewith:"St.LucieTSC,thisistheSt.LucieEOFconductingacommunicationstest,howdoyouread,over?"IftheTSCconfirmscleartransmissionandyoucanconfirmclearreceptionoftheresponse,thenhavetheradioswitchedtochannelF1(bydepressingthe"F1/F2"button),followingterminationofthemessage,andstandbyforatest.Endthetransmissionwith:"ThisisSt.LucieEOF,out."Iftransmissionisunsuccessful,calltheTSCandhavetheradioswitchedtochannelF1.Proceedtothenextstep.d.NowtesttheradiowhichissettochannelF1.Transmitthefollowing:"St.LucieTSC,thisisSt.LucieEOF,comeinplease,over."FollowingacknowledgementfromtheTSC,continuewith:"St.LucieTSC,thisisSt.LucieEOFconductingacommunicationstest,howdoyouread,over?"IftheTSCconfirmsacleartransmissionandyoucanconfirmclearreceptionoftheresponse,thenendthetransmissionwith:"Thisconcludesthiscommunicationstest,resettheradiotochannelF2,thisisSt.LucieEOFKNGR874overandout."Iftransmissionisunsuccessful,calltheTSCandhavetheradioresettochannelF2.Proceedtothenextstep.e.Recordoperabilitystatusontheinventoryform(Attachment6).f.Ifoneorbothchannelsofthesystemis/areinoperable,thennotifyanEmergencyPreparednessCoordinatorortheEmergencyPreparednessSupervisor.3.PoweringDowntheRadio:a.Unplugthephonecablesfrombothradiosfromthewallphonejacks.b.Unplugbothradiosfromthewalloutlets.
Page50of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTAPPENDIXBINSTRUCTIONSFORTESTINGEMERGENCYCOMMUNICATIONSEQUIPMENT(Sheet11of15)IV.(continued)J.HPOff-siteChannelisaunique900MHzchannel(TX939.9375-RX900.9375)forcommunicationswiththeoff-siteFieldMonitoringTeams.TheradioisaMotorolaSpectrawhichhasbeensetupsothattheHPOff-siteChannelisthe"home"channel,butithasalsobeenprogrammedforotherchannelsoftheplant900MHztrunkingsystem.1.PoweringUptheRadio:a.Plugthepowercordintothewalloutletbehindthetable.b.Presstheredbuttononthespeakerbox(AstronRS-12S)totheupposition,buttonwillilluminate.c.Depressthe"pwr"buttonontheSpectraradio.2.InstructionsforTesting:a.ContactsomeoneattheplanttogototheTSCtoassistwiththeradiotest,ifnotpreviouslyarranged.b.Thehomechannelis"off-site,"ifthischannelisnotselected(ontheLED),thendepressthe"sel"buttonuntil"off-site"showsinthedisplay.c.Pressthetransmitside(withthelightningbolt)ofthemicrophonebaseandannounce:"St.LucieTSC,thisistheSt.LucieEOF,comeinplease,over."FollowingacknowledgementfromtheTSC,continuewith:"St.LucieTSC,thisistheSt.LucieEOFconductingacommunicationstest,howdoyouread?"IftheTSCconfirmscleartransmissionandyoucanconfirmclearreceptionoftheresponse,thenendthetransmissionwith:"Thisconcludesthiscommunicationstest,thisisSt.LucieEOF,WMIF540overandout."d.Recordoperabilitystatusontheinventoryform(Attachment6).e.Iftheradioisinoperable,thennotifyanEmergencyPreparednessCoordinatorortheEmergencyPreparednessSupervisor.
Page51of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTAPPENDIXBINSTRUCTIONSFORTESTINGEMERGENCYCOMMUNICATIONSEQUIPMENT(Sheet12of15)IV.(continued)J.(continued)3.PoweringDowntheRadio:a.Depressthe"pwr"buttonontheSpectraradio.b.Pressredbuttonofthespeakerboxtothedownposition(lightwillextinguish).c.Unplugthepowercordfromthewalloutlet.K.TheStateWarningPoint(SWP)HotRingDown(HRD)circuitisadedicatedphonesystemlinkingtheStateagencies,St.LucieCountyandMartinCountywiththePlantControlRooms,TechnicalSupportCenterandtheEmergencyOperationsFacility.1.InstructionsforTesting.a.GototheDivisionofEmergencyManagement'sofficeRoom108,intheEOFandlocatethephonelabeledHotRingDown(HRD).b.PickupthehandsetanddialtheStateWarningPoint(SWP)inTallahassee.Thisisdonebydialing100.TheStateWarningPointDutyOfficerwillacknowledgebysaying,"ThisisStateWarningPoint,goahead."Youinturnwillannounce"ThisisSt.LucieEOF,Iamconductingacommunicationscheck,howdoyoureceiveme?TheStatewillacknowledge.RequesttheStateWarningPointtocallyoubackonStationnumber123.
Page52of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTAPPENDIXBINSTRUCTIONSFORTESTINGEMERGENCYCOMMUNICATIONSEQUIPMENT(Sheet13of15)IV.(continued)K.(continued)1.(continued)c.Selftestprocedureforadditionalextensions.(1)Conductaselfteston2extensions.A.Extension120intheconferenceroomB.Extensions122and124inthebullpen/R37(2)Toperformtheselftest,adjustthevolumecontroltothemid-rangeposition.Liftthehandsetandpressthepushtotalkbarwhilespeakingintothehandsetmouthpiece.Youshouldhearyourselfinthehandsetearpiece(thisiscalledsidetone).Nowlocatetheblackbuttonontherearofthetelephonenexttothepowerconnector.Activatethetestmodebyholdingthisbuttondownwhilesimultaneouslydepressingthepushtotalkbarandspeakingintothehandsetmouthpiece.Voiceshouldnowbeheardinthespeaker.Satisfactorycompletionoftheselftestisdeterminedwhenthepresenceofsidetoneisdetectedwhilepressingthepushtotalkbarandspeakingintothehandset,andwhenaloopbackofthespeaker'svoiceisheardintheloudspeakerwhilepressingthetestswitchlocatedontherearoftheterminal.Theselftestisacompleteaudioloopbackoftheterminal'saudiocircuitsupto,butnotincluding,thelinematchingtransformers.Assuch,thistestisagoodmethodtoevaluateinstrumentperformance.d.Recordoperabilitystatusontheinventoryform(Attachment6)~e.Ifthesystemisinoperable,notifyanEmergencyPreparednessCoordinatorortheEmergencyPreparednessSupervisor.
Page53of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTAPPENDIXBINSTRUCTIONSFORTESTINGEMERGENCYCOMMUNICATIONSEQUIPMENT(Sheet14of15)IV.(continued)L."Videolink"-the"Videolink"isaclosedcircuitaudio/visualcommunicationslinkoriginatingintheTSCwithfeedstotheOSCandtheEOF.1.InstructionsforTestinga.ContactsomeoneattheplanttogototheTSCtoassistwiththetestofthe"Videolink",ifnotpreviouslyarranged.b.Obtainkey¹14fromthekeyboxinroom107.Thekeytothekeyboxislocatedonthewallnexttothe.box.c.Usekey¹14tounlockroom132.d.Turnonthemastervideoswitchlocatedintherackmountcabinet.e.Inthe"Bullpen",room101,turnonthetwotelevisionsetsusingtheremotecontrols(oneforeachtelevisionset)ontheRecoveryManager'stable.f.Setthechannelselectortochannel7andadjustvolume.g.RequestthepersonintheTSCtoprovideatestbroadcast.h.Operabilityisverifiedifboththevideopictureandtheaudiooutputarereceivedonbothtelevisionsets.Thepicturemustbeclearandtheaudiofreefromstatic.i.Recordoperabilitystatusontheinventoryform(Attachment6)~j.Ifthe"Videolink"isinoperable(oneorbothtelevisionsets),notifyEmergencyPlanning.
Page54of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTAPPENDIXBINSTRUCTIONSFORTESTINGEMERGENCYCOMMUNICATIONSEQUIPMENT(Sheet15of15)IV.(continued)L.(continued)(continued)k.Followingthecompletionofthetest:1.Turnoffbothtelevisionsetsinroom101.2.Turnoffthemastervideoswitchinroom132.3.Lockroom132.4.Returnkey¹14tothekeybox.V.SiteAssemblyStationA.ConductfunctionalcheckoftheSiteAssemblyStation(SAS)telephonelocatedonthewestwall.1~Placealocalcallandrequestacallbacktoensurethatthephoneworksproperly.2.Recordoperabilitystatusontheinventoryform(Attachment4)~3.Ifthephoneisinoperable,notifyEmergencyPlanning.
Page55of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTAPPENDIXCFAXTESTFOREOFMACHINESTO:EPDEPT467-7514THISISATESTFROM:DATE:~~
Page56of56ST.LUCIEPLANTHEALTHPHYSICSOPERATINGPROCEDURENO.HP-90,REVISION37EMERGENCYEQUIPMENTAPPENDIXDCOPIERTESTFOREOFMACHINESTESTDATE~~TESTPERFORMEDBY hI0 Title:FPLST.LUCIEPLANTHEALTHPHYSICSPROCEDURESAFETYRELATEDProcedureNo.HP-200CurrentRev.No.16EffectiveDate:03/27/0tHEALTHPHYSICSEMERGENCYORGANIZATIONResponsibleDepartment:RevisionSummaryHEALTHPHYSICSRevision16-AddedsteptoTSCHPSupervisorchecklisttoassistECwithradiologicalconditionsandevaluationsofPARs.Madeeditorial/administrativechanges.(J.R.Walker,03/22/01)Revision15-DeletedlowvolairsamplefromOSCchecklistandincludedchecklistforHPNCommunicator.(DonReisinger,11/30/99)Revision14-Clarifiedradiationprotectiontechnologistandhealthphysicstechnicianpositions.AddedEALtriggerstoTSCHPSChecklist,OSCrelocationthresholddoserateinformationtoHPOSCChecklistandeditorialchanges.(J.R.Walker,3/2/99)Q0OPROCEDURF.pgpDUCTIOhjRevisionFRGReviewDate1603/22/01RevisionFRGReviewDate02/01/62ApprovedByJ.H.BarrowforPlantGeneralManagerApprovedByR.G.WestPlantGeneralManagerN/ADesignatedApproverN/ADesignatedApprover(MinorCorrection)ApprovalDate02/04/82ApprovalDate03/22/01SOPSDATEDOCTPROCEDUREDOCNHP-200SYSCOMPCOMPLETEDITM16
~'
Page2of211.0TITLE:ST.LUCIEPLANTHEALTHPHYSICSPROCEDURENO.HP-200,REVISION16HEALTHPHYSICSEMERGENCYORGANIZATIONHEALTHPHYSICSEMERGENCYORGANIZATION2.0REVIEWANDAPPROVAL:Seecoverpage3.0PURPOSE:ThisproceduredefinesareasofresponsibilityandprovidesgeneralguidelinesforactiontobetakenbyHealthPhysicsDepartmentpersonneluponimplementationoftheSt.LuciePlantRadiologicalEmergencyPlan(E-Plan).ItalsoreferencesthoseHealthPhysics(HP)proceduresnecessarytocarryoutspecificHPactivitiesduringadeclaredradiologicalemergency(Alert,SiteAreaEmergencyandGeneralEmergency).4.0PRECAUTIONSANDLIMITATIONS:4.1TheHealthPhysicsDepartmentisresponsibleforprotectingallpersonnelfromexcessiveradiologicalexposuresduringaccidentconditions.Inordertoeffectivelycarryoutthisresponsibility,itisnecessarythatallHPpersonnelquicklymantheiremergencystationsandassembleandchecktheirequipmentandawaitdirectionsfromtheTechnicalSupportCenterHealthPhysicsSupervisor(TSCHPS)orhisdesignee.4.2TheTSCHPSisresponsiblefortheprocedurestobeimplementedandwhenimplementationistobeeffected.4.3Completeallproceduralstepsifapplicableorindicateasnon-applicablebywritingN/Aintheprovidedblank.4.4WhenHealthPhysicsnormaloperatingproceduresandemergencyproceduresdiffer,theemergencyprocedurestakeprecedence.4.5DelegationofdutiesandwatchreliefsshallbeauthorizedonlybytheTSCHPSorhisdesigneewithapprovaloftheEmergencyCoordinator.4.6Itistheresponsibilityofallpersonneltolimittheirownexposureandtoassistothersinlimitingtheirexposures.
ST.LUCIEPLANTHEALTHPHYSICSPROCEDURENO.HP-200,REVISION16HEALTHPHYSICSEMERGENCYORGANIZATION5.0RELATEDSYSTEMSTATUS:Page3of21None
6.0REFERENCES
- 6.1St.LuciePlantRadiologicalEmergencyPlan(E-Plan)6.2E-PlanImplementingProcedures(EPIP00-13)6.3HP-2,"FPBLHealthPhysicsManual"6.4NRCl8EInformationNoticeNo.86-97:EmergencyCommunicationsSystem6.5HP-201,"EmergencyPersonnelExposureControl"6.6HP-202,"EnvironmentalMonitoiingDuringEmergencies"6.7HP-203,"PersonnelAccessControlDuringEmergencies"6.8HP-204,"In-PlantRadiationandContaminationSurveysDuringEmergencies"6.9HP-205,"EmergencyIn-PlantAirSampling"6.10HP-206,"AnalysisofEmergencyIn-PlantAirSamples"6.11HP-207,"MonitoringEvacuatedPersonnelDuringEmergencies"6.12HP-208,"PersonnelDecontaminationDuringEmergencies"6.13PMAIPM97-04-148,OSCMerlins ST.LUCIEPLANTHEALTHPHYSICSPROCEDURENO.HP-200,REVISION16HEALTHPHYSICSEMERGENCYORGANIZATION7.0RECORDSREQUIRED:Page4of217.1CompletedcopiesofthebelowlisteddocumentsshallbemaintainedintheplantfilesinaccordancewithQI-17-PSL-1,"QualityAssuranceRecords."Formssimilarto:1.FormHP200.1,TechnicalSupportCenterHealthPhysicsSupervisorChecklist2.FormHP200.2,HealthPhysicsOSCSupervisor(HPOSC)Checklist3.FormHP200.3,HPNCommunicatorChecklist ST.LUCIEPLANTHEALTHPHYSICSPROCEDURENO.HP-200,REVISION16HEALTHPHYSICSEMERGENCYORGANIZATION8.0INSTRUCTIONS:Page5of218.1HealthPhysicsEmergencyOrganizationTECHNICALSUPPORTCENTERHEALTHPHYSICSSUPERVISOR(TSCHPS)TheHealthPhysics(HP)Supervisororhisalternate(seetheSt.LuciePlantEmergencyResponseDirectory(ERD))shallassumedutiesastheTSCHPSintheTechnicalSupportCenter(TSC).HeisresponsibleforallHPactivitiesandreportstotheEmergencyCoordinator(EC).ATSCHPSChecklist,FormHP-200.1isprovidedinthisprocedure.SeeSection8.2forinstructionstobefollowedpriortoactivationoftheTSCand/orpriortoarrivaloftheTSCHPS.HEALTHPHYSICSOSCSUPERVISOR(HPOSC)TheseniorHPOperationsSupervisorshallassumedutiesastheHPSupervisorintheOperationalSupportCenter(HPOSC)~HereportstotheTSCHPSintheTSC.HeisresponsibleforcoordinatingallHPactivitiesfromtheOperationalSupportCenter(OSC).AHPOSCSupervisorChecklist,FormHP-200.2isprovidedinthisprocedure.HEALTHPHYSICSTECHNICALSTAFF/R16/R16TheHealthPhysicsTechnicalStaffshallreportimmediatelytotheTSCHPSforassignment.HEALTHPHYSICSTECHNICIAN(HPT)RadiationProtectionTechnologists(RPTs)assumetheroleofHealthPhysicsTechnicians(HPTs=OSCHPTech)andshallimmediatelyreporttoorbeincontactwiththeOSC.TheywillbeassigneddutiesbytheHPOSC./R168.2ON-SHIFTHEALTHPHYSICSRESPONSETOEMERGENCIESAnEmergencyClassdeclarationofanAlertorhigherduringoff-normalworkinghourswillrequireadditionalHPstaffing.TheseniorHPrepresentativeon-sitewillimplementtheHPemergencyprocedures.Itisexpectedthatthisinitialperiodwilllastforaboutonehour./R16/R16 Page6of21ST.LUCIEPLANTHEALTHPHYSICSPROCEDURENO.HP-200,REVISION16HEALTHPHYSICSEMERGENCYORGANIZATION8.0INSTRUCTIONS:(continued)8.2(continued)2.TheseniorHPrepresentativeon-siteshallnotifytheEmergencyCoordinatorandapprisehimofHPassistanceavailableon-site.HewilltakehisordersdirectlyfromtheEmergencyCoordinatorandshouldassumehisdutiesintheplantorOSCandnotintheTSCunlessotherwisedirectedbytheEmergencyCoordinator.HeshouldattempttoremaininapositiontobereachedbytheEmergencyCoordinatorifnecessary./R163.Sincetherewillbeonlylimitedhealthphysicscoverageavailable,itisveryimportantfortheseniorHPrepresentativeon-sitetodiscusswiththeEmergencyCoordinator(orhisdesignee)thecoveragewhicheachfeelsisnecessaryandtoprioritizethatcoverage.Thefollowinglistmaybeusedtoassistinthedecisionofassigningpriorities:(inorderofpreference)/R16A.RadiologicalcoveragenecessarytoallowexpediententrytoareaswhenrequiredtoplacetheplantinasafeconditionB.TreatmentofcontaminatedpersonnelC.RadiologicalcoverageduringhighactivitysamplingD.Preparationsforextensivein-plantmonitoringandsurveillance4.WhentheadditionalHPsupportarrives,theinitialperiodwillhavepassed.InordertomaintaincontinuityandtoeffectasmoothtransferfromtheinterimtothefullystaffedmodeitisnecessarythattheHPcommandfunctionnotchangehandsmorethanisabsolutelynecessary.Therefore,eventhoughtheseniorHPrepresentativeon-sitecanberelievedbyamoreseniorTechnologistorSupervisor,heshouldnotberelievedbyanyoneexcepttheHPSupervisororhisalternate./R16HPpersonnelshallreporttotheOSCwhentheyarriveon-siteandshouldcontacttheseniorHPrepresentativeon-siteforassignments./R165.TheseniorHPrepresentativeon-siteshallinitiatetheTSCHPS'sChecklist,FormHP-200.1./R16 ST.LUCIEPLANTHEALTHPHYSICSPROCEDURENO.HP-200,REVISION16HEALTHPHYSICSEMERGENCYORGANIZATION8.0INSTRUCTIONS:(continued)8.3HealthPhysicsEmergencyOperationsAreasPage7of211.OperationsHPpersonnelwillassembleinandworkoutoftheOSC.HPTechnicalStaffpersonnelwillassembleandworkprimarilyintheTSC.2.TheTSCHPSwilldetermineiftheaffectedunitReactorAuxiliaryBuilding(RAB)ControlPointistobemannedandwillinformtheECandtheHPOSC.3.IftheaffectedunitRABControlPointbecomesuntenable,theTSCHPSwilldirecttheHPOSCtomantheRABControlPointoftheunaffectedunitordesignateanalternateControlPoint.TheTSCHPSwillinformtheECofthealternatelocation.8ALogisticsandSupplies1.RecordsandlogsspecifiedinthespecificHPemergencyproceduresshallbekeptuptodateandshallbereviewedbytheTSCHPS.2.Emergencyradiationprotectionsuppliesarelocatedforuseinthefollowingplaces:1.RABControlPoints(Unit1&Unit2)2.OperationalSupportCenter(OSC)3.SiteAssemblyStation(SAS)4.Unit1ControlRoom(forusebyTSCandUnit1C.R.personnel)5.Unit2ControlRoom3.TheHPOSCwillensurethatmaterialsandequipmentareprovidedtooperatingareasasneeded.
Page8of21ST.LUCIEPLANTHEALTHPHYSICSPROCEDURENO.HP-200,REVISION16HEALTHPHYSICSEMERGENCYORGANIZATION8.0INSTRUCTIONS:(continued)8.5EmergencyPersonnelExposureControl(HP-201)TheTSCHPSshallensurethatallpersonnelon-siteduringemergencyoperationswearproperdosimetry.Heshalldeterminewhenspecialdosimetryisrequired.2.TheHPTsthroughtheHPOSCwillprovideradiologicalsurveysand/orcoverageforallareasinwhichpersonnelaccessisrequired.3.Ifpersonnelexposuresarelikelytoexceedplantguidelines,theguidelinesinHealthPhysicsProcedureHP-201,"EmergencyPersonnelExposureControl,"shallbefollowed.4.AllpersonnelexposuresduringemergencyoperationswillbemaintainedAsLowAsReasonablyAchievable-ALARA.8.6Off-siteandOn-SiteEnvironmentalMonitoring(HP-202)1.TheEmergencyCoordinatorisresponsibleforensuringthattheTSCHPSinitiatesoff-siteradiologicalmonitoring,inaccordancewiththeE-Plan,withina10mileradiusoftheplant.Off-sitefieldmonitoringactivitieswillbecoordinatedwiththeStateofFlorida./R162.TheTSCHPSwilldirecttheHPOSCtodispatchtheFieldMonitoringTeamstotheSiteAssemblyStation.NOTEIftheFieldMonitoringTeamcommunicator/controlhasnotbeenactivated,theFieldMonitoringTeamsshouldmakecontactwiththeOSCandreporttheirstatus.3.TheFieldMonitoringTeamswillassembletheirequipment,checkitforoperabilityandestablishcontactwiththeTSC.TheTSCHPSintheTSCprovidessupervisionfortheFieldMonitoringTeamsasperEPIP-10,"Off-siteRadiologicalMonitoring,"andHP-202,"EnvironmentalMonitoringDuringEmergencies."
Page9of21ST.LUCIEPLANTHEALTHPHYSICSPROCEDURENO.HP-200,REVISION16HEALTHPHYSICSEMERGENCYORGANIZATION8.0INSTRUCTIONS:(continued)8.7PersonnelAccessControl(HP-203)Nore-entryintoareasaffectedbytheemergencyshallbemadeunlessauthorizedbytheEmergencyCoordinator.2.TheinitialentryoftheRe-entryTeamandallsubsequententries,untilradiationareashavebeenproperlymarked,shalltakeplaceunderthesupervisionoftheTSCHPSasperEPIP-05,"ActivationandOperationoftheOperationalSupportCenter."3.Followingre-entryprocedures,theTSCHPSwilldirecttheHPOSCtoestablishtheaccesscontrolpoint(s).TheHPTsshallmaintainaccesscontroltoallaffectedareasoftheplantforthepurposeofcontrollingpersonnelexposuresasperHP-203,"PersonnelAccessControlDuringEmergencies."8.8RadiationandContaminationSurveys(HP-204)NOTEIntheeventofaSteamGeneratorTubeRupture(SGTR),thefollowingareasshouldinitiallybepostedascontaminated:A..SteamTrestleB.CondenserAirEjectorC.CondensatePolisher1.TheEmergencyCoordinatorandTSCHPSwilldeterminetheextentofsurveysrequired.2.TheTSCHPSwilldirecttheHPOSCtoestablishsurveyteamsutilizingthebuddysystem.TheHPOSCwilldirecttheconductofallin-plantsurveys,ensuredataisproperlyrecordedandpostedandkeeptheTSCHPSinformedoftheresults.3.Surveillanceforemergencysituationshallincludeasaminimum:Radiationsurveys2.Contaminationsurveys Page10of21ST.LUCIEPLANTHEALTHPHYSICSPROCEDURENO.HP-200,REVISION16HEALTHPHYSICSEMERGENCYORGANIZATION8.0INSTRUCTIONS:(continued)8.8(continued)3.(continued)3.Airborneactivitysurveys4.Radiologicalmonitoringofpotentiallyhighactivitychemistrysampleoperations5.SurveysascalledforintheEmergencyOperatingProcedures(EOPs).6.SpecialsurveysasdeterminedbytheTSCHPS.8.9In-PlantAirSamplingandCounting(HP-205,HP-206)1.Duringanemergency,higherthannormalradiationlevelsandairborneconcentrationscanbeexpected.Itisimportantthatsamplingbecommencedasexpeditiouslyaspossibletosupportrapidre-entryifnecessary.2.Allin-plantairsamplingwillbeperformedinsuchamannerastoensurepersonnelexposuresareALARA.3.TheproceduresHP-205,"EmergencyIn-PlantAirSampling"andHP-206,"AnalysisofEmergencyIn-PlantAirSamples,"shouldbefollowedinsamplingandanalyzingsamples.8.10PersonnelMonitoringFollowingEvacuation(HP-207)1~Intheeventitbecomesnecessarytoevacuatepersonnelfromtheplantandareleasehasoccurredorisinprogress,checkpointswillbeestablishedimmediatelytoallowmonitoringofthesepersonnel.ThecheckpointswillbeatJayceePark,unlessalternateroutesandassemblylocationsarespecifiedbytheEC.
Page11of21ST.LUCIEPLANTHEALTHPHYSICSPROCEDURENO.HP-200,REVISION16HEALTHPHYSICSEMERGENCYORGANIZATION8.0INSTRUCTIONS:(continued)8.11PersonnelDecontamination(HP-208)1~Personneldecontaminationfollowinganaccidentcanposespecialproblemsnotencounteredineverydaysituationsincludingextremelyhighlevelsofcontaminationand/orlargenumbersofpersonnelbeingcontaminatedatthesametime.2.PersonneldecontaminationattheOff-siteAssemblyAreawillbeunderthecognizanceoftheTSCHPSandwillbedirectedbyhisdesigneeatthatarea.HP-208,"PersonnelDecontaminationDuringEmergencies,"addressesoff-sitepersonneldecontamination./R163.Personneldecontaminationon-sitewillbeunderthedirectionoftheHPOSCandshouldbeconductedinthehotshowerareaoftheunaffectedunitoratalocationspecifiedbytheTSCHPS.
Page12of21ST.LUCIEPLANTHEALTHPHYSICSPROCEDURENO.HP-200,REVISION16HEALTHPHYSICSEMERGENCYORGANIZATIONHP200.1TECHNICALSUPPORTCENTERHEALTHPHYSICSSUPERVISORCHECKLISTINITIAL1.ContacttheOSCandassessavailableHPresourcesonsite:a.TSCHPNetworkCommunicatorFieldMonitoringTeamCommunicatorb.OSCNumberofHPTechsNumberofDosimetryTechsNumberofUtilityWorkersHPOSCSupervisorc.NumberofHPTsassignedtoUnit1ControlRoomd.NumberofHPTsassignedtoUnit2ControlRoom/R16 Page13of21ST.LUCIEPLANTHEALTHPHYSICSPROCEDURENO.HP-200,REVISION16HEALTHPHYSICSEMERGENCYORGANIZATIONHP200.1TECHNICALSUPPORTCENTERHEALTHPHYSICSSUPERVISORCHECKLIST(continued)INITIALCAUTIONBeawareofthefollowingconditions.TheseEmergencyActionLevels(EALs)areassociatedwithInitiatingConditions(ICs)usedintheclassificationofemergencies(EPIP-01,ClassificationofEmergencies)theEmergencyCoordinatorneedstoknowifanyoftheseconditionsexist.1.Measureddoseratesfromoff-sitesurveysatthesiteboundary(1mile)exceedeitherofthefollowing:a.1000mrem/hr(totaldoserate)b.5000mrem/hr(thyroiddoserate)2.ContactEmerencCoordinatorECa.InformECofHPDepartmentstatusintheTSCandOSC.b.DetermineandprioritizeimmediateHPcoverageneeds:NOTEOperationswillrequirethatradiationsurveysbeconductedtosupporttheEOPs.~PrioritJob/Location¹HPsReuired/R16 Page14of21ST.LUCIEPLANTHEALTHPHYSICSPROCEDURENO.HP-200,REVISION16HEALTHPHYSICSEMERGENCYORGANIZATIONHP200.1TECHNICALSUPPORTCENTERHEALTHPHYSICSSUPERVISORCHECKLIST(continued)2.(continued)c.EventClassificationDate/TimeINITIALa)UNUSUALEVENTb)ALERTc)SITEAREAEMERGENCYd)GENERALEMERGENCY3.OSCConsiderationsa.EstablishcommunicationswiththeOSC(ifactivated).b.AppointHPOSCSupervisorName:Phone:c.InformHPOSCtocompleteHPOSCChecklistHP-200.2.d.Exchangeinformationonplantstatus,eventclassification,availablepersonnelandprioritizejobsrequiringHPcoverage.Also,discussplanningstrategiesandpersonnelallocations.e.DirectHPOSCtodispatchFieldMonitoringTeamsaccordingtothefollowingclassificationschedule:ALERTOn-site,outofplant-1Team(RED)SITEAREAOROn-site,outofplant-1Team(RED)GENERALEMERGENCYandoff-site-2Teams(ORANGE,BLUE)/R16 Page15of21ST.LUCIEPLANTHEALTHPHYSICSPROCEDURENO.HP-200,REVISION16HEALTHPHYSICSEMERGENCYORGANIZATIONHP200.1TECHNICALSUPPORTCENTERHEALTHPHYSICSSUPERVISORCHECKLIST(continued)3.(continued)INITIALNOTEItispossiblefortheTSCandOSCtobeinoperationforweeksfollowingaplantaccident.ItistheTSCHPSresponsibilitytodeterminewhentoactivatefriskingstationsforthosefacilitiesandthelocationsofthosestations.Oncefriskingisinitiatedallpersonnelenteringthesefacilitiesshallbemonitoredforcontamination.f.DirectHPOSCtoestablishRCA/RABaccesscontrolpointsifportionsoftheRCAwereevacuatedorRABre-entryisplanned.CONTROLPOINTLOCATIONSg.IfaSiteEvacuationhasbeenorderedandareleasehasoccurredorisinprogress,directtheHPOSCtodispatchtwoHPTstotheOff-SiteAssemblyAreatomonitortheevacuees.h.IfadditionalHPpersonnelresourcesmaybeneeded,considerrequestingassistancethrough:PTNIndustry(throughINPO)DepartmentofEnergy(throughNRC)4.TSCConsiderationsa.InconjunctionwiththeTSCChemistrySupervisor,advisetheECand/orTSCECAssist/LogkeeperonradiologicalconditionsandProtectiveActionRecommendations,asnecessary./R16 Page16of21ST.LUCIEPLANTHEALTHPHYSICSPROCEDURENO.HP-200,REVISION16HEALTHPHYSICSEMERGENCYORGANIZATIONHP200.1TECHNICALSUPPORTCENTERHEALTHPHYSICSSUPERVISORCHECKLIST(continued)4.(continued)b.AssignpersontocontinuouslymantheHealthPhysicsNetwork(HPN)phone.(Ref.I8ENotice86-97)c.ContacttheTSCChemistrySupervisortodetermineifaccidentsamplesarerequired(yes/no).d.Assignpersontodirectfieldmonitoringteamsandevaluatethedataasitbecomesavailable.INITIALe.Conferwithchemistryand/ortheEOFondoseprojectionsandeffectedEPZsectors.f.EstablishcommunicationsbetweentheTSCFieldMonitoringTeamandtheEOFFieldMonitoringCoordinator(whenactivated).1.ExchangenamesandphonenumbersName(s)2.Relayfieldmonitoringresultsasavailable.Phone¹/R16 Page17of21ST.LUCIEPLANTHEALTHPHYSICSPROCEDURENO.HP-200,REVISION16HEALTHPHYSICSEMERGENCYORGANIZATIONHP200.1TECHNICALSUPPORTCENTERHEALTHPHYSICSSUPERVISORCHECKLIST(continued)4.(continued)g.Directthathabitabilitysurveysofthefollowingareasareperformed.ControlRoomNo.12.ControlRoomNo.23.TSC(turnonCAM)4.OSC5.RABControlPoints(ifinhabited)SurveysofTSCandControlRoomsshouldbecompletedbypersonnelassignedtothoseareas.5.AdditionalCommentsbTSCHPS:INITIALCompletedby:DateCompleted:~jNOTEFilethisChecklistinaccordancewithQI-17-PSL-1,"QualityAssuranceRecords."/R16 Page18of21ST.LUCIEPLANTHEALTHPHYSICSPROCEDURENO.HP-200,REVISION16HEALTHPHYSICSEMERGENCYORGANIZATIONHP200.2HPOSCSUPERVISORCHECKLISTINITIAL1~PerformaccountabilityofHPTsandprovidetoOSCSupervisor:NOTEConsulttheRadiationExposureSummaryReportforselectionofrespiratorqualifiedfieldmonitoringteammembers.2.Dispatchon-siteFieldMonitoringTeamtoSiteAssemblyStationwhendirectedbyTSCHPS.1HPT,1driverandvehicle.3.Dispatchoff-siteFieldMonitoringTeamstoSiteAssemblyStationwhendirectedbyTSCHPS.2HPTs,2drivers,2vehicles.4.IfRCAisNOTEVACUATEDstartpreparationsforaccumulatingsuppliesandinstrumentsintheeventofRCAevacuation.5.IfRCAisNOTEVACUATEDperformnecessaryjobcoverageforOPSormaintenancepersonnelattemptingtomitigatetheproblem./R16 Page19of21ST.LUCIEPLANTHEALTHPHYSICSPROCEDURENO.HP-200,REVISION16HEALTHPHYSICSEMERGENCYORGANIZATIONHP200.2HPOSCSUPERVISORCHECKLIST(continued)INITIAL6.IfRCAevacuationisnecessary,performthefollowing:1~DispatchHPTtoeachControlRoom2.RemoveInstrumentstoOSC3.TakeboxesofElectronicDosimetersfromRABentrancestationstoOSC.4.DetermineH.P.PersonnelavailableinOSCReporttotheTSCHPSandOSCSupervisor5.EstablishOSCaccesscontrolpoints(s)6.EstablishDosimetrySectioninOSC.7.EstablishContaminationControlforOSC.8.InformTSCHPS9.SetupaContinuousMonitoringCountRateMeterInOSCCAUTIONTheOSCaffordslimitedprotectionagainstareleaseofradioactivematerial.Duringthetimethataradioactivereleaseisoccurring,thehabitabilityoftheOSCistobemonitored.Ameasureddoserateof50mrem/hr,inthefacility,isestablishedasthethresholdforrelocationoftheOSC.10.PerformhabitabilitysurveysoftheOSCand,ifinhabited,RABControlPointandprovidesurveyresultstoTSCHPS./R16
Page20of21ST.LUCIEPLANTHEALTHPHYSICSPROCEDURENO.HP-200,REVISION16HEALTHPHYSICSEMERGENCYORGANIZATIONHP200.2HPOSCSUPERVISORCHECKLIST(continued)INITIAL7.IfdirectedbytheTSCHPS,dispatchtwoHPTstotheoffsiteassemblyarea:Name:Name:DispatchTime:DispatchTime:8.EnsureallReentryTeamsareadequatelybriefedinaccordancewithHP-203.1priortobeingdispatchedfromtheOSC.9.AdviseandassisttheOSCSupervisorasnecessaryinactionstomitigateaccident.10.HPOSCSupervisorComments:Completedby:DateCompteted:~~NOTEFilethisChecklistinaccordancewithQI-17-PSL-1,"QualityAssuranceRecords."/R16 Page21of21ST.LUCIEPLANTHEALTHPHYSICSPROCEDURENO.HP-200;REVISION16HEALTHPHYSICSEMERGENCYORGANIZATIONHP200.3HPNCOMMUNICATORCHECKLISTINITIAL1.Report/Signin/ObtainIDBadge.2.GetstatusfromTSCHPS.3.GetHPsupplycase&,procedures.TypicalHPNQuestions:A.MeteorologicalDataB.ReleasedataC.PlantradiologicalinquiriesD.FieldteamdataE.AssistFMTCoordinatorNOTE4.ActivateHPNphone:A.CallNRC-Identifyself8activity.B.RequesttobecoupledtotheHPNbridgenetwork.5.ReviewERDADS(PlantRadMonitorData).6.Reviewoff-siteDoseRadAssessmentBoard.7.Reviewoff-sitemonitoringfieldteamstatusboard.8.ProvidedatatoTSCHPS./R16/R169.AssistTSCHPSasneeded(dispensedosimetry,set-upairmonitor,TSCRadSurveys,provideradmonitordata,etc.).NOTEFilethisChecklistinaccordancewithQI-17-PSL-1,QualityAssuranceRecords.
ig~~++~~~<>>+~~+y+>>~~/+/~<+sr'E'+guJyyyd>fProcedureNo.FPLST.LUCIEPLANTEMERGENCYPLANIMPLEMENTINGPROCEDURESAFETYRELATEDEPIP-0CurrentResionNo.ffectiveDate06/15/0'tCTIVATIONANDOPERATIO,GETH.TECHNICALSUPPORTCET'esponsibleDeprtment:EMERGENCYPREPAREDNES/SI-XOREVISIONSUMMAR:Revision8-Reducedpperworkrequiredtorequere-entryteams,streamlinedre-entry,andstreamlinedproblemlvingteampaperworkDonnaCalabrese,04/26/01)Revision7-Revisedmandatoryfunctions$oincludeclassificationandPARs,removedreferencestoSTA,revisedresponsibilitie<oftheTSCECAssist/LogkeeperandTSCChemistrySupervisor,andmadeditor'andadministrativechanges.(J~R.Walker,12/07/00)Revision6-Changedresponsibi)iyfillingintheStateNotificationFormfromtheTSCHRDCommunicationtotheTSCJECAsist/Logkeeper.Madeeditorialandadministrativechanges.RevisedTSCbriefingguidanceWCR00-0429.AddednewPSTTrackingform.(DonnaCalabrese,05/31/00~Revision5-ChangedCPemtstryminimumstapositionfromTSCChemSupvtoTSCDoseAssessor,addressedPMAIbyprovidingalternateotificationmethods,addedinstructiontoproducelistofEptPwithcurrentrev.numbers,reviedre-entryworksheet,addedinstructiontocreateconf.brit/eforOPS,andmadeeditorialandministrativechanges.(J.R.Walker,11/18/99)Revision4-RemovedreferencetotherotatingmaintenanceshiftsupervisorfillingthepositiofTSCcoordinatorwithOSC.(J.R.Walker,07/01/99)/Revision0Revision8FRGReviewDate12/15/97FRGReviewDate04/26/01ApprovedByJ.ScarolaPlantGeneralManagerApprovedByR.G.WestPlantGeneralManagerN/ADesignatedApproverN/ADesignatedApprover(MinorCorrection)Approv(Date12/15/5ApprovalDate04/26/01SOPSDATEDOCTPROCEDUREDQCNEPIP-04sYsCOMcoMPLETEDIs8
REVISIONNO.:PROCEDURENO.:EPIP-04SECTION1.0PURPOSEPROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTTABLEOFCONTENTSPAGE:2of83PAGE
2.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTS.......63.0RESPONSIBILITIES4.0DEFINITIONS5.0INSTRUCTIONSATTACHMENTSATTACHMENT1TSCEMERGENCYRESPONSEORGANIZATIONANDSHIFTSTAFFINGATTACHMENT2TSCECASSIST/LOGKEEPERCHECKLIST....1013....14ATTACHMENT2ATYPICALINFORMATIONTOBEINCLUDEDINTHEECLOGBOOK16ATTACHMENT3TSCSUPERVISORCHECKLIST~~~~~~~~i17ATTACHMENT3ATSCEROSHIFTSTAFFINGANDACCOUNTABILITYROSTER.ATTACHMENT3BTSCMINIMUMSTAFFINGREQUIREMENTSATTACHMENT3CTSCFACILITYBRIEFINGSATTACHMENT3DGUIDELINESFORRELOCATIONOFTHETSC....ATTACHMENT4TSCCOMMUNICATORCHECKLIST.ATTACHMENT4ACOMMUNICATIONSGUIDELINES2122....23....252832ATTACHMENT4BSAFETYFUNCTIONSEQUIPMENTSTATUS-UNIT1.......39 REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTTABLEOFCONTENTS(continued)PAGE:3of83SECTIONATTACHMENTS(continued)ATTACHMENT5TSCERDADSOPERATORCHECKLIST.ATTACHMENT5AERDADSDATAACQUISITION.ATTACHMENT5BERDADSDATAPOINTSATTACHMENT6TSCADMINISTRATIVESTAFFCHECKLIST.....PAGE.43.45.48....56ATTACHMENT7TSCCOORDINATORWITHOSCCHECKLIST...................59ATTACHMENT7ARE-ENTRYLOG.ATTACHMENT8TSCOPSCOORDINATORCHECKLIST.....ATTACHMENT9TSCREACTORENGINEERCHECKLIST.606165ATTACHMENT9AINITIATINGANDTERMINATINGTHEERDSLINK~~~..........68ATTACHMENT10TSCCHEMISTRYSUPERVISORCHECKLIST.........ATTACHMENT11TSCDOSEASSESSORCHECKLIST.ATTACHMENT11AOFF-SITERADIOLOGICALASSESSMENTATTACHMENT11BPROTECTIVEACTIONRECOMMENDATIONS..........ATTACHMENT12TSCPROBLEMSOLVINGTEAMCHECKLIST.........ATTACHMENT12APSTACTIVITIESLIST.ATTACHMENT12BPROBLEMSOLVINGTEAMWORKSHEET....ATTACHMENT13TSCSECURITYSUPERVISORCHECKLIST....707375....76.7779....8081 REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:4of83'I.0PURPOSE1.1DiscussionThisprocedureprovidesinstructionsfortheactivationandoperationoftheTechnicalSupportCenter(TSC).1.2LocationandDescriptionTheTSCisonthe62footelevationoftheUnit1ReactorAuxiliaryBuilding(RAB).TheTSCislocatedadjacenttotheUnit1ControlRoomandisenclosedinthesamehabitabilityenvelope.TheTSChasemergencycommunicationsequipment,precalculatedemergencydata,pertinentreports,plans,proceduresanddrawingsavailableforuse.ShouldtheUnit1ControlRoomenveloperequireevacuation,alternatelocationsfortheTSChavebeenidentifiedasfollows:1~SouthServiceBuilding2.NuclearTrainingCenter1.3TSCFunctions1.MandatoryFunctionsA.ClassificationofemergenciesinaccordancewithEPIP-01,ClassificationofEmergencies.NOTEThefollowingtasksbecometheresponsibilityoftheEmergencyOperationsFacilitEOFwhenmannedandfulloerational.B.RelieftotheControlRoomforoff-sitecommunicationstotheStateandlocalagenciesandtheNRCinaccordancewithEPIP-08,Off-siteNotificationsandProtectiveActionRecommendations.C.Performanceofoff-sitedosecalculationsinaccordancewithEPIP-09,Off-siteDoseCalculations,ortheClassAcomputermodel.D.ProtectiveActionRecommendations(PARs)inaccordancewithEPIP-08.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:5of831.3TSCFunctions(continued)2.AdditionalFunctionsA.Managementofemergencymitigationactivities.B.Technicalsupportindeterminingcurrentandprojectedplantstatusandprovidingin-depthdiagnosticandengineeringassistancetotheControlRoom.C.Directthere-entryactivitiesoftheOperationalSupportCenter(OSC).CoordinationwiththeEmergencyOperationsFacility(EOF)regardingemergencystatus,correctiveandprotectiveactions,off-siteinterface,radiologicalconditions,coredamageassessment,etc.1.4MinimumStaffing1~ThefollowingisthelistoftheminimumpositionsneededforTSCoperation:EmergencyCoordinatorTSCSupervisorTSCDoseAssessorTSCReactorEngineerTSCElecRep-PST(ProblemSolvingTeam)TSCMechRep-PST(3)TSCCommunicator(HRD,ENS,EOF)1.5g2ActivationActivationoftheTSCistheresponsibilityoftheEmergencyCoordinator(EC)andisrequiredforanAlertorhigherdeclaredemergency.ArrangementshavebeenmadetostafftheTSCinatimelymanner.1.6OperationsTheTSChassufficientspacetoaccommodatetheFloridaPower&LightCompany(FPL)responseorganizationanddesignatedrepresentativesoftheNuclearRegulatoryCommission(NRC)SiteTeam.Arrangementshavebeenmadewhichallowforcontinuousoperation,asnecessary.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:6of8
32.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTSNOTEOneormoreofthefollowingsymbolsmaybeusedinthisprocedure:IndicatesaRegulatorycommitmentmadebyTechnicalSpecifications,ConditionofLicense,Audit,LER,Bulletin,OperatingExperience,etc.andshallNOTberevisedwithoutFacilityReviewGroupreviewandPlantGeneralManagerapproval.Indicatesamanagementdirective,vendorrecommendation,plantpracticeorothernon-regulatorycommitmentthatshouldNOTberevisedwithoutconsultationwiththeplantstaff.'PIndicatesastethatreuiresasinoffonanattachment.2.1Referencesg~St.LuciePlantTechnicalSpecificationsUnit1andUnit2(Section6.10.1)2.3.a.5.6.St.LuciePlantUpdatedFinalSafetyAnalysisReport(UFSAR)Unit1andUnit2St.LuciePlantRadiologicalEmergencyPlan(E-Plan)$3St.LuciePlantTopicalQualityAssuranceReport(TQAR)E-PlanImplementingProcedures(EPIP00-13)HP-200SeriesProcedures7.ADM-17.09,Invoking10CFR50.54(x)8.ADM-17.11,10CFR50.59Screening9.St.LuciePlantEmergencyResponseDirectory(ERD)10.QI-17-PSL-1,QualityAssuranceRecords11.ERDADSReactorOperator'sManual(8770-12058)12.St.LuciePlantSevereAccidentManagementGuidelines(SAMGs)
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:7of832.1References(continued)13.g4FitnessforDutyRule,10CFR2614.NUREG1394,EmergencyResponseDataSystem(ERDS)15.ConditionReport01-0169(TSC/Unit1CRHVACCharcoalFiltrationChangeOut)2.2RecordsRequired1.Thefollowingshallberetainedfollowingaplantemergency:Checklists,dataandpaperworkgeneratedperthisprocedure.Logbooksmaintainedduringtheplantemergency.2.g~RecordedinformationshallbeforwardedtoEmergencyPlanningfollowingtheevent,forreviewandarchivalinaccordancewithTechnicalSpecification6.10.1andQI-17-PSL-1.2.3CommitmentDocumentsPMAIPM97-04-142,TrainingDrillCritique1/24/97,(ERDADSscreenmimicsandfullstaffingguidance)2.3.4.5.6.ConditionReport97-1389,(EmergencySupplies)PMAIPM99-09-017,TrainingDrillCritique7/22/99,(AlternateNotificationMethods)g4PMAIPM96-09-185,ConditionReportCR96-1750(Off-siteNotificationUsingCommercialPhone)ConditionReport00-0429(TSCBriefing)ConditionReport01-0078(Re-entryPaperworkandResponseTimeExpectations)
REVISIONNo.:PROCEDURENo.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:Sof833.0RESPONSIBILITIES3.1EmergencyCoordinator(EC)1.TheresponsibilitiesforthispositionareprovidedinEPIP-02,DutiesandResponsibilitiesoftheEmergencyCoordinator.3.2TSCECAssist/Logkeeper1.InitiatesandmaintainstheECLogbook.2.ProvidesassistancetotheECtoensureECresponsibilitiesaremet,particularlyoff-sitenotificationsandProtectiveActionRecommendations(PARs).3.Performsdutiesasdirected/assignedbytheEC.3.3TSCSupervisor1~ProvidescommandandcontrolofTSCactivities.2.SupervisestheTSCstaffparticularlythecommunicatorsandadministrativepersonnel.3.CoordinatesactivitiestoensureadequatesupportoftheEC.Ensurescommunicationsareperformedwithoff-siteagenciesuntiltheEOFisactivated.5.EnsuresthecommunicationflowismaintainedwithinthefacilityandwiththeControlRoom,OSCandEOF.6.Coordinatesfacilitybriefings.7.ArrangesforlongtermoperationoftheTSC.3.4TSCCoordinatorwiththeOSC1.ServesasthecoordinatorwiththeOSC.2.ProvidestheOSCwithrequestsforRe-entryTeams.3.Tracksthere-entryactivitiesoftheOSC.4.UpdatestheTSCregardingOSCteamstatusandcorrectiveactions.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:9of833.5TSCOPSCoordinatorNOTEThispositionisfilledbytwopersons,onelocatedintheaffectedunit'sControlRoom,theotherintheTSC.2.ProvidesexpertiseinplantoperationstotheECintheTSC.ProvidescommunicationsassistancetotheNPSintheaffectedControlRoom.3.4.5.Ensurestheunaffectedunit'sControlRoomiskeptapprisedofthestatusoftheemergency.MaintainscommunicationflowbetweentheTSCandtheaffectedControlRoomconcerningstatusofoperations.ServesasprimarySevereAccidentManagementGuidelines(SAMG)decisionmaker.3.6TSCReactorEngineer1~Monitorscriticalsafetyfunctionsforindicationsofcorestatus.2.AssistsNuclearFuelspersonnelintheEOFinassessmentofcoredamage.3.AssistsinSevereAccidentManagementGuidelines(SAMG)evaluation.3.7TSCChemistrySupervisor1.DirectsdoseassessmentactivitiesintheTSC.2.AssiststheECwithProtectiveActionRecommendations(PARs).3.KeepstheECapprisedofchemistryrelatedissues.4.AssiststheChemistrySupervisorintheOSC.3.8TSCHPSupervisor(TSCHPS)1.TheresponsibilitiesforthispositionareprovidedinHP-200,HealthPhysicsEmergencyOrganization.
REVISIONNO.:PROCEDURENo.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:10of833.9TSCSecuritySupervisor1.Establishesandmaintainssiteaccountability.2.ArrangessiteaccessfortheNRCSiteTeam.3.Controlson-sitesecurityoperationsthroughouttheemergency.3.10TSCProblemSolvingTeam(PST)2.3.4.5.EvaluatesplantconditionsandprovidesrecommendationstotheEC.Anticipatescomponentfailuresandaccidentconsequences.Researchesaffectedsystemsandcomponents.Developsmitigationstrategiesand/orcountermeasures.PerformsSevereAccidentManagementGuidelines(SAMG)evaluation.4.0DEFINITIONS4.1FacilityStatusActivation-therequesttostaffandestablishanEmergencyResponseFacility(ERF).2.Operational-whensufficientpersonnel(i.e.,minimumstaff)areavailabletoaccomplishmandatoryfacilityfunctionssuchasoff-sitenotificationsanddosecalculations.3.FullyStaffed-thecompletecomplementofpersonnelispresentinthefacility.4.2FPLEmergencyRecallSystem(ERS)-thecall-outsystemusedasameansofoffhourscall-out,asdescribedinEPIP-03,EmergencyResponseOrganization/StaffAugmentation.4.3Videolink-aclosedcircuitaudio/visualcommunicationslinkoriginatingintheTSCwithfeedstotheOSCandtheEOFallowingtheECbriefingstobeavailableinalltheEmergencyResponseFacilities(ERFs).
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:11of835.0INSTRUCTIONSNOTE~ThissectionprovidesgeneralinformationandinstructionsforallTSCresponders.~Positionspecificchecklistsareincludedasattachmentstothisprocedure.~IndividualsspecificallydesignatedasmembersoftheTSCEmergencyResonseOranizationEROareidentifiedintheERD.5.1Whennotified,TSCemergencyrespondersaretoreporttothefacilityasquicklyaspossible.5.2TheinitialrespondertotheTSCshoulddothefollowing:1~UnlockthefacilitywithakeyfromtheNPSorAssistantNuclearPlantSupervisor(ANPS).Ifthesepersonsareunavailable,breaktheglasstothekeyboxnexttothedoorandremovethekey.2.Turnonthefacilitylights.3.Openallfacilityequipment/documentstoragecabinets.5.3Uponarrivalatthefacility,eachTSCemergencyrespondershouldperformthefollowing:Sign-inon:A.thestatusboardontheSouth(rear)wallofthefacilityinthespacecorrespondingtoyourpositionand2.3.4.5.B.theTSCEROShiftStaffingandAccountabilityRoster.Obtainyourspecificpositionnotebookfromthestoragecabinet.Placeyournameonyourposition(player)badge(locatedinthepositionnotebook)withadryerasemarkerorinanyothernonpermanentmanner.Makeyourworkstation/locationoperational.NotifyyoursupervisorortheTSCSupervisorofyourreadinessstatus.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:12of835.4QOnlycontrolledcopiesofnuclearsafety-relatedprocedures,drawingsandotheravailableplantinformationshallbeused.Non-controlleddocumentsordrawingsshouldbeverifiedwithacontrolledcopypriortouseintheTSC.5.5Duringfacilitybriefings,stopwhatyouaredoing,payattentionandcontribute,asrequested.5.6Uponterminationoftheevent:AllTSCpersonnelshouldreturntheirworkstations/locationstoanormalstateandassistinrestoringthefacilitytoareadycondition.2.Collectallsignificantinformationanddocumentation,suchascompletedEPIPsandattachments,logs,notificationformsandothernotesanddatasheets(notboundinthepositionnotebooks),andprovidethismaterialtotheTSCSupervisor.ENDOFSECTION5.0 REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:13of83ATTACHMENT1TSCEMERGENCYRESPONSEORGANIZATIONANDSHIFTSTAFFING(Page1of1)101EMERGENCYCOORDINATORI102TSCSupervisorIIIr>>3TSCSPPhcnetattterI(LocatedInO>>ContrdAcorn.)113TSCSPPhonetaltter114TSCERDADSOper118TSCERDADSTech121TSCAdtn'nStaN(2)108TSC~ter(3),O(ENSComm)~(HRDComm)0(EOFComnt)124TSCECAsstlLogkoopor122TSCEPCoordinator(Notarequiredpost(on)TSCCoordinatorwiglOSCr"---158OSCCoordinatorwithTSC((coatedIntheOSC.)r----a1110ITSCOPSCoordhater~(LocatedIntheControlAoom.)110TSCOPSCoordnator105~TSCReactorEnoer103TSCHPSu112TSCHPComm(2)(HPNComm)(FMTComm)115TSCPSTLeader0107TSCElecRep.PST0108TSCMechRepPST(2)(NoteI)117TSCIaoRep.PST118TSCSAOAep-PST104TSCChetnlstty111TSCDoseAssessortrsttest119TSCSecuritySupervisor(P/PSIEPJPO4IAItrdrc)AutodialerpositionnumborsarolistodwithpositiontitleL~30minutorosponSOgaal,porNUREG0654,Table81o60mlnutorosponsogoal,perNUREG0654,Tablo8.1Noto1-OnlyonopersonInthoTSCMechRepPSTpositionIsrequiredasminimumstaff.Noto2.ThoDosoAssossorfunctionwTIbopodormodbytheon.shiftChemist.~IndicatesminimumstaffingpositionsthatmustboftlledinordertododarothofacilityoperatlonaLENDOFATTACHMENT1 REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:14of83ATTACHMENT2TSCECASSIST/LOGKEEPERCHECKLIST(Page1of2)NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofseuence.A.B.FACILITYACTIVATION1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.FACILITYOPERATIONRemovetheECLogbookfromtheECpositionnotebookandinitiatetheECLog(useAttachment2A,TypicalInformationtobeIncludedintheECLogbook).INITIAL2.3.ReviewtherequirementsofEPIP-02,DutiesandResponsibilitiesoftheEmergencyCoordinator.Stepstooccurcontinuallywhilethefacilityisinoperation:aOC.d.e.g.MaintaintheECLogbook.AssisttheECinthecompletionoftherequirementsofEPIP-02.PriortotheEmergencyOperationsFacilitygoingoperational,assisttheECincompletionoftheStateNotificationForm,includingdeterminationofProtectiveActionRecommendations(PARs),asnecessaryinaccordancewithEPIP-08,Off-siteNotificationsandProtectiveActionRecommendations.VerifythattheECapprovesalloff-sitenotificationforms.RemindtheECoftimelimitsfornotificationofoff-siteagencies.Ensurechecklists/paperworkareproperlycompleted.ProvideECasummaryofrecentlogentriesforfacilitybriefings.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:15of83B.C.ATTACHMENT2TSCECASSISTILOGKEEPERCHECKLIST(Page2of2)3.(continued)h.SupportECasneededorrequested.i.AssisttheEmergencyNotificationSystem(ENS)CommunicatorinrespondingtorequestsforinformationfromtheNRC.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAIIpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.Ensuredallfacilityactivitiesclosedout.2.ClosedouttheECLog,returnedtheLogbooktotheECpositionnotebookandreturnedthenotebooktothestoragecabinet.3.4.5.Ensuredallpaperworkcollected.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheTSCSupervisor.Returnedpositionnotebooktostoragecabinet.ENDOFATTACHMENT2 REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:16of83ATTACHMENT2ATYPICALINFORMATIONTOBEINCLUDEDINTHEECLOGBOOK(Page1of1)Maintainingconcise,detailedlogsduringanemergencyeventisimportant.Followingtheevent,allinformationrecordedwillbeneededtoprovideaclearpictureofactionstaken.A.B.ThefollowinginformationshouldbeincludedintheECLogbook:1.Keyevents(e.g.,classificationchanges,injuries,etc.).2.Statuschangesinequipment,radiologicalconditions,personnel,etc.3.Decisionsmadeoractionstaken.4.Otheritemsofsignificance.Logentryrequirements:2.3.4.5.6.Timeofentry.Useink.Write/printlegibly.Useconciseandaccuratewording.Strikethroughandinitialchanges.Donotremovepagesfromthelog.ENDOFATTACHMENT2A REVISIONNo.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:17of83ATTACHMENT3TSCSUPERVISORCHECKLIST(Page1of4)NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofseuence.A.FACILITYACTIVATIONINITIAL2.RefertoSection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.DetermineoperationalreadinessoftheTSCbyverifyingthefollowing:NOTEAttachment3B,TSCMinimumStaffingRequirements,shouldbeusedtodeterminestaffandsuitablealternates.80Minimumstaffavailable(usetoAttachment3A,TSCEROShiftStaffingandAccountabilityRoster)~Communicationsequipment,proceduresandothersuppliesareavailable,checkedandreadytouse.CommercialphoneasbackuptoState/CountyandNRCNotifications(DONOTtestcallHRDorENS).ExtensionphonesinTSC.Procedure,drawing,techmanualcabinetsunlocked.Instructpersonneltoverifytheirpositionnotebookproceduresagainstthepostedrevisionnumbers.c.Minimumstaffpreparedtoaccomplishmandatoryfacilityfunctions.3.RecommendtotheECthattheTSCshouldbedeclaredoperational.Operationalat REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:18of83A.(continued)ATTACHMENT3TSCSUPERVISORCHECKLIST(Page2of4)INITIALNOTEIf~UnlessauthorizedbytheEC,facilitystaffingshouldbeinaccordancewithAttachment3A,TSCEROShiftStaffinandAccountabilitRoster.4.ReviewadditionalstaffingstatuswiththeEC.5.6.TSCfullystaffed.EnsurethattheEClog,completednotificationformsandchecklistsandanyotherpertinentinformationhavebeenfaxedtotheEOF.B.FACILITYOPERATION1.InitiatetheTSCLogbook.NOTETheTSCReactorEngineerisresponsibleforestablishingthecommunicationbetweentheSt.LuciePlant'sEmergencyResponseDataAcquisitionandDisplaySystem(ERDADS)andtheNRC'sEmergencyResonseDataSstemERDS.2.3.4.5.6.EnsureERDADSLinkwiththeNRC(ERDS)established/attempted.ObtainfoodandwatersupplyfortheUnit1ControlRoom/TSCpersonnel.ObtainfoodandwatersupplyfortheUnit2ControlRoompersonnel.Arrangeforlongtermstaffing(useAttachment3A,TSCEROShiftStaffingandAccountabilityRoster).AsdirectedbytheEC,initiatestepsforrelocationoftheTSC(useAttachment3D,GuidelinesforRelocationoftheTSC).
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:19of83B.(continued)ATTACHMENT3TSCSUPERVISORCHECKLIST(Page3of4)INITIAL7.Stepstooccurcontinuallywhilethefacilityisinoperation:80C.MaintaintheTSCLogbook.Manage/superviseactivitiesofTSCCommunicators(HRD,ENS,EOF,HPN,Sound-PoweredPhonetalker,FMT).Manage/superviseactivitiesoftheTSCAdministrativeStaff.C.d.Maintainlownoiselevelsinthefacility.e.CoordinateoverallsupportfunctionsoftheTSC.f.ConductbriefingsinaccordancewithAttachment3C,TSCFacilityBriefings.g.EnsuretheOSCiskeptwellinformedregardingemergencystatusandplantconditions(anaudio/videolinkmaybeusedforthispurpose).h.EnsuretheEOFiskeptwellinformedregardingemergencystatusandplantconditions(anaudio/videolinkmaybeusedforthispurpose).FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.2.3.4.Allcommunicationslinksterminated.Allcommunicationspaperworkcollected.AIIfacilityactivitiesclosedout.Alldocuments,equipmentandsuppliesreturnedtopre-activationconditionand/orlocation.
0 REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT3TSCSUPERVISORCHECKLIST(Page4of4)PAGE:20of83C.(continued)INITIAL5.6.7.ClosedoutTSCLogbook.Providedallcompletedpaperwork(notboundinthepositionnotebook(s))toEmergencyPlanning.Returnedpositionnotebooktostoragecabinet.ENDOFATTACHMENT3 REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT3ATSCEROSHIFTSTAFFINGANDACCOUNTABILITYROSTER(Page1of1)PAGE:21of83POSITIONMinimumStaffinBold3Shift'HoursBADGENO.ToPOSITIONMinimumStaffinBoldNAMEBADGENO.EmergencyCoordinatorTSCHPSupervisorTSCSupervisorTSCHPCommTSCReactorEngineerTSCHPCommTSCDoseAssessorTSCChemSupervisorTSCCommunicatorTSCOPSCoord(TSC)TSCCommunicator'SCOPSCoord(CR)TSCCommunicator'SCSPPhonetaiker(TSC)TSCElecRep-PSTTSCSPPhonetaiker(CR)TSCMechRep-PSTTSCCoordinatorwithOSCTSCMechRep-PSTTSCERDADSOperatorTSCMechRep-PSTTSCERDADSTechTSCI&CRep-PSTTSCAdminStaffTSCSRORep-PSTTSCAdminStaffTSCPSTLeaderTSCSecuritySupvTSCECAssist/LogkeeperTSCEPCoord(notrequired)Longtermstaffing,refertotheSt.LuciaPlantEmergencyResponseDirectory(ERD)forpositionalternates.LongtermstaffingincludestheControlRooms,attachlisttothissheet.RefertoAttachment3B,TSCMinimumStaffingRequirements,tothisattachmentfortemporaryalternatesforminimumstaffpositions.TSCCommunicatorpositionfillsthefollowingpositions:a.TSCENSCommunicatorb.TSCHRDCommunicatorc.TSCEOFCommunicatorPositionmayberelievedwhentheEOFgoesoperationalandtakestheleadfordoseassessment.ENDOFATTACHMENT3A REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:22of83ATTACHMENT3BTSCMINIMUMSTAFFINGREQUIREMENTS(Page1of1)MajorFunctionalArea'eniorMgmt.Rep.Off-siteDoseAssessmentCore/ThermalHydraulicsNotification/CommunicationElectricalMechanicalFacilityCommandandControlPositionTitleandIDNo.EmergencyCoordinator,101TSCDoseAssessor,111TSCReactorEngineer,105TSCCommunicator,106TSCElecRep-PST,107TSCMechRep-PST,108TSCSupervisor,102ffinPositionQualifications/TemoraAlternateSeniorManagerwithEmergencyCoordinatorualificationsMemberofChemistDeartmentMemberoftheReactorEngineeringDeartmentorcurrentorriorSTATSCresponderwith-STAorequivalentbackgroundforENSCommunicator-Technical/operationalbackgroundforHRDorEOFCommunicatorElectricalEngineerorElectricalMaintenanceSuervisorMechanicalEngineerorMechanicalMaintenanceSuervisorTSCCoordinatorwithOSCThisfunction(s)maybeaccomplishedduringthefirst75minutesofanemergencybyanindividual(s)meetingthecorrespondinglistedqualifications.2TheseEmergencyResponseOrganization(ERO)positionswereestablishedtoaccomplishtheindicatedfunction(s).ENDOFATTACHMENT3B REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:23of83ATTACHMENT3CTSCFACILITYBRIEFINGS(Page1of2)NOTEBriefinsshouldbecarriedbtheVideolink.A.GENERALGUIDELINES2.3.CoordinatedbytheTSCSupervisororhis/herdesignee:a.Establishafrequency(e.g.,approximatelyevery30minutes).Frequencyofbriefingsmaybechanged(e.g.,decreasedduringaprotractedeventorincreasedduringrapidlychangingconditions).b.Setcriteria(i.e.,attendance,noiseandactivitylevel,collectionandcirculationofinformation,etc.).TSCSupervisorshouldannouncethestartofthebriefingandthenturnthebriefingovertotheEC.TSCSupervisorshouldassisttheECduringthebriefing.aOEnsurethattheECreceivesanyupdatedinformation.CoordinatethiswiththeTSCECAssistant/Logkeeper.b.EnsurethattheECrepeatsanyquestionsthatareaskedfromthefloortoensurethattheOSCandEOFmembershaveheardthem.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:24of83ATTACHMENT3CTSCFACILITYBRIEFINGS(Page2of2)B.GENERALFORMAT-thefollowinginformationshouldbeincludedinfacilitybriefings.NOTEItisnotnecessarytohavealldepartmentrepresentativesparticipateineachbriefing.Usediscretioninthisareatoavoidunnecessaryrepetitionofinformation.3.4.Initialstatusandsummarytoinclude:a.Timeofthebriefing.b.EmergencyClassification.c.Plantstatus(affectedunit,unaffectedunit).d.Radiologicalconditions(e.g.,releaseinprogress,contaminatedareas,etc.).e.Statusofprotectiveactions(e.g.,siteevacuation,actionsunderwaybythepublic,etc.).f.Statusofactivitiesunderwayinthefacility.g.Priorityactivities/primaryfocus.Input/updateinformationfromotherdepartments:a.Operations(includingEOPactions,discussionofSAMGs)~b.HealthPhysics(includingfieldmonitoringactivities)~c.ReactorEngineering(includingstatusofthereactorcore).d.ProblemSolvingTeam(includingSAMGs).e.TSCCoordinatorwiththeOSC(includingre-entryactivitystatus).Majoractivitiesunderwayinotherfacilities.Concernsorquestions.ENDOFATTACHMENT3C REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:25of83ATTACHMENT3DGUIDELINESFORRELOCATIONOFTHETSC(Page1of3)IfhabitabilityoftheUnit1ControlRoomischallenged(e.g.,duetofire/smoke)andevacuationisrequired,theTSCwillneedtoberelocated.Thefollowingguidelinesareprovidedtoassistinthisendeavor.A.EmerencCoordinator1.TransfertheresponsibilitiesoftheECasfollows:a.Classificationoftheemergency-NPSNOTETheEOF,onceoperational,hasresponsibilityforrecommendingprotectiveactionsandforoff-sitenotifications.b.C.d.ProtectiveActionRecommendations(PARs)-NPSDecisiontonotifyoff-siteofficialsandthecontentofnotificationmessages-NPSRequesttheunaffectedControlRoomANPStosupporttheNPSinoff-sitenotifications.B.2.ConductatransferofECresponsibilitieswiththeNPS(viaphoneconversation)oncethealternateTSCispreparedtogooperational.T~SCS2.InconjunctionwiththeECandtheTSCHPSupervisor,determinetheappropriateareatorelocatetheTSC.Chooseoneofthefollowing:a.SouthServiceBuildingb.NuclearTrainingCenterDirecttheevacuationbybriefingTSCpersonnelonlocation,travelroute,materialstotakeandanyimmediateactionspriortoleavingthefacility(e.g.,formallyterminatecommunications,turnoffequipment,etc.)
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:26of83B.(continued)ATTACHMENT3DGUIDELINESFORRELOCATIONOFTHETSC(Page2of3)C.3.Re-establishcommandandcontrolofTSCfunctionsasquicklyaspossible.a.Transfertheresponsibilityforoff-sitenotificationsfromtheunaffectedControlRoom(ifthisresponsibilityhasnotbeentransferredtotheEOF)tothecommunicatorsintherelocatedTSC.AllTSCPersonnel2.3.4.5.Formallydiscontinuecommunications.Gatherpositionnotebooksandotherpertinentmaterials.TravelpertheprescribedroutetothealternateTSClocation.AssistSecurityinre-establishingaccountabilityasquicklyaspossible.Re-establishTSCfunctionsasquicklyaspossible.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:27of83ATTACHMENT3DGUIDELINESFORRELOCATIONOFTHETSC(Page3of3)SuggestedArrangementsandEquipmentAvailabilityatAlternateTSCLocations:SOUTHSERVICEBUILDINGNUCLEARTRAININGCENTERCommunicationsHRDPhoneENSPhoneHPNPhoneEOFPhoneFMTRadioDoseAssessmentClassAModelEPareafourthfloorAnycommercialphoneAnycommercialphoneAnycommercialphoneEPareafourthfloorEPareafourthfloorSimulatorAnycommercialphoneAnycommercialphoneAnycommercialphoneSimulatorTechnicalTrainingareasecondfloorTSCFunctionsCommandandControlEPareafourthfloorConferenceroomandSupervisorofficessecondfloorProblemSolvingTeamOtherEngineeringareathirdfloorCubiclessecondandfourthfloorConferenceroomsecondfloorCubiclessecondfloorENDOFATTACHMENT3D REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT4TSCCOMMUNICATORCHECKLIST(Page1of4)PAGE:28of83NOTE1.ThischecklistappliestothefollowingCommunicatorpositionsintheTSC:HRDCommunicatorEOFCommunicatorENSCommunicatorSound-poweredPhonetalker(CR/TSC)2.TheresponsibilitiesoftheTSCHPCommunicatorsareprovidedasfollows:HPNCommunicator-inHP-200,HealthPhysicsEmergencyOrganizationFMTComm/Coord-inEPIP-10,Off-siteRadiologicalMonitoring3.Whennecessaryorappropriate,stepsofthischecklistmaybeerformedoutofseuence.A,FACILITYACTIVATION1.RefertoSection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.INITIALNOTECommunicatorpositionsshouldbefilledinthefollowingorder:1.HotRingDown(HRD)Phone2.EmergencyNotificationSystem(ENS)3.EOF4.Sound-poweredPhone(CR)5.Sound-oweredPhoneSC2.Fillingthepositionof3.ReviewappropriateinformationinAttachment4A,CommunicationsGuidelines.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:29of83ATTACHMENT4TSCCOMMUNICATORCHECKLIST(Page2of4)B.FACILITYOPERATIONStepstooccurcontinuallywhilethefacilityisinoperation:HRDCommunicationsa.AssisttheECwithStateandCountynotificationsby:1.ReviewingtheStateNotificationFormforcompleteness.Asnecessary,ensuringProtectiveActionRecommendations(PARs)matchthePARWorksheet(seeAttachment3,DeterminationofProtectiveActionRecommendation(PARs)inEPIP-08,Off-siteNotificationsandProtectiveActionRecommendations).3.EnsuretheEChasapprovedtheform.b.TransmitthenotificationforminaccordancewithAppendixB,NotificationsfromtheTechnicalSupportCenter(TSC),EPIP-08.c.RequesttheTSCECAssist/Logkeeperlognotificationtimes.d.FollowingturnoverofnotificationresponsibilitytotheEOFHRDCommunicator,identifyavailabilitytotheTSCSupervisor.Bepreparedtoprovideassistanceasrequested.ENSCommunicationsaeIfnecessary,transmitaninitialNRCNotificationForminaccordancewithEPIP-08.C.d.AtanAlertorhigheremergencyclassification,requesttheNRCtoestablishtheENSconferencebridge.Maintainanopenlineofcommunicationandatransmissionlog.RequesttheTSCECAssist/Logkeeper:1.ProvideassistanceinrespondingtorequestsforinformationfromtheNRC.2.Lognotificationtimes,asappropriate.
REVISIONNO.:PROCEDURENo.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:30of83ATTACHMENT4TSCCOMMUNICATORCHECKLIST(Page3of4)(continued)ENSCommunications(continued)e.LogallquestionsaskedbyNRC.g.ObtainanswerstoquestionsfromappropriateTSCstaffmember(e.g.,HP,Chemistry,ReactorEngineering,etc.),asnecessary.ObtainECapprovalpriortoprovidingadditionalinformationtotheNRC.EOFCommunicationsa.MaintainanopenlineofcommunicationwiththeEOF.b.IfERDADSisoutofservice,useAttachment4B,SafetyFunctionsEquipmentStatusandRadioactiveGaseousSourceTerms,toobtainplantparameterandradiologicaldata(useAttachment4B)viatheSound-poweredPhonetalkerandsharetheinformationwiththeEOF(viatheTSCCommunicatorintheEOF).c.ProvideclarificationofanydiscrepantinformationasrequestedbytheEOF.Sound-poweredPhonetalkera.ProvideanopenlineofcommunicationbetweentheaffectedControlRoomandtheTSC.b.Providefanstatusfordoseassessment.C.Provideclarificationofdataand/orobtainadditionaldataasrequestedbytheTSC.IfERDADSisoutofservice,useAttachment4B,SafetyFunctionsEquipmentStatusandRadioactiveGaseousSourceTerms,toobtainplantparameterandradiologicaldata.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT4TSCCOMMUNICATORCHECKLISTPAGE:31of83(Page4of4)C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.2.4.5.Allcommunicationslinks(HRD,ENS,EOF,Sound-poweredphone)terminated.Allcommunicationspaperworkcollected.Allphoneequipmentreturnedtopre-activationcondition.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheTSCSupervisor.Returnedpositionnotebooktostoragecabinet.ENDOFATTACHMENT4 REVISIONNO.:PROCEDURENo.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:32of83ATTACHMENT4ACOMMUNICATIONSGUIDELINES(Page1of7)NOTEIfcommunicationsareassociatedwithdrillorexercise,thestatement"Thisisadrill"shouldrecedeandfollowtheactualmessae.A.GENERALGUIDELINESAlwaysspeakclearly,firmlyandwithnormaltonewhenusinganycommunicationsystem.2.Thesenderandreceivershouldbeclearlyidentified.Messagetext:80Communicationmustbefreeofambiguity.Slangtermsshouldnotbeused.Avoidtheuseofwordsthatsoundalike;forexample,avoidincreaseanddecrease,useraiseandlowerinstead.C.Communicationsmustbespecific.Usenounnamesforplantequipment,notacronyms;forexampleLowPressureSafetyInjectionPumpinsteadofLPSI.Thephoneticalphabetshouldbeusedtoidentifyspecifictrain,bus,channelorequipmentdesignations,notjustletteridentifier;forexample,refertothe1Alphaheaterdrainpump,notthe1Aheaterdrainpump.Thefollowingisthephoneticalphabettobeused:ABCDEFGHIAlphaBravoCharlieDeltaEchoFoxtrotGolfHotelIndiaJKLMN0PQRJulietKiloLimaMikeNovemberOscarPapaQuebecRomeoSTUVWXYZSierraTangoUniformVictorWhiskeyX-rayYankeeZulud.Thephoneticalphabetshouldnotbeusedforstringedletterreferences,acceptableacronymsorlocationsymbols;forexample,ABbus,ACorDC,TSC,respectively.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:33of83ATTACHMENT4ACOMMUNICATIONSGUIDELINES(Page2of7)A.(continued)4.Acknowledgementandconfirmation(3-waycommunication)-messagesshallbecomprisedofpropertransmission,acknowledgement,andconfirmation.a.Themessageisproperlytransmittedfromtheoriginatortothereceiver.b.Themessagereceivershouldacknowledgethecommunicationbygivingfunctionalrepeat-backtothemessageoriginator.Therepeat-backcanbeprovidedbyeitherparaphrasingorexplainingthemessageinone'sownwords,orbyverbatimrepeat-back.Inallcases,verbatimrepeat-backshouldbeusedforequipmentidentifiers.c.Ifthemessagereceiverdoesnotunderstandthemessagehe/sheshouldaskforthemessagetoberepeated.d.Ifanincorrectrepeat-backisgiven,themessageoriginatorshouldimmediatelycorrectthemiscommunicationwithastatementsuchas,"WRONG",followedbyrestatingthecorrectmessage.5.6.7.8.e.Themessageoriginatorshouldconfirmtheacknowledgement(repeat-back)withastatementsuchas,"Thatiscorrect".TheCallSignshouldbeusedperiodicallywhenusingtheLocalGovernmentRadio(LGR).Priortotransmission,ensurethatinformationhasbeenverifiedandapprovedbytheappropriateauthority,asnecessary.EnsurethatanyincomingpertinentinformationisprovidedtotheTSCSupervisorandtheEmergencyCoordinatorordesignee.Maintaindocumentationofanysignificantinformationprovidedorreceived.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:34of83ATTACHMENT4ACOMMUNICATIONSGUIDELINES(Page3of7)B.COMMUNICATIONSSYSTEMSStateWarningPoint(SWP)HotRingDownPhone(HRD)a.b.ThisistheprimarycommunicationspathwaytotheStateWarningPointandSt.LucieandMartinCounties.Aself-verifyingphonesystemwhichisinitiatedbyenteringthe3digitcodecorrespondingtothedesiredlocationofcontact.Thecodesappearonalistinapull-outdrawerattachedtothebaseofthephoneorintheSt.LuciePlantEmergencyResponseDirectory(ERD).Aconfirmationring-back(doubletone)willbeheardifthedialedterminalissuccessfullycontacted.Whenthepartyanswers,begintransmissionbydepressingthe"push-to-talk"barinthehandset.Releasethe"push-to-talk"bartoreceiveresponse.2.NRCEmergencyNotificationSystem(ENS)aOb.ThisistheprimarycommunicationspathwaytotheNRC.PartoftheNRCEmergencyTelecommunicationsSystem(ETS)~Initiatecontactbydialing(direct,noaccesscodeneeded)oneofthephonenumbersprovidedonthephoneorintheERD.ThiswillbecomeanopenlineofcommunicationattheAlertorhigheremergencyclass.TheEOFwilljointheconferencebridge.EOFDirect-lineTelephonea0ThisisadirectlinetotheEmergencyOperationsFacility(EOF).InitiatecontactbyremovingthehandsetfromthecradlewhichwillcausethephoneintheEOFtoring.Whenthephoneisanswered,begintransmission.ThislinkcanalsobeinitiatedfromtheEOF.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:35of83ATTACHMENT4ACOMMUNICATIONSGUIDELINES(Page4of7)B.(continued)4.Sound-poweredPhonea.Asthenameimplies,thesephone(headsets)arepoweredbysound.b.TheUnit1phonejackislocatedneartheDoseAssessmentStatusBoard;theUnit2phonejackislocatednexttotheChronologyStatusBoardintherearoftheroom.c.OncetheheadsetshavebeenconnectedinboththeaffectedControlRoomandtheTSC,transmissioncanbeginbyspeakingintothemouthpiece.5.CommercialTelephone6.a.ThisisthefirstalternatecommunicationspathwaytotheStateWarningPointandSt.Lucie,MartinCounties,andNRC.b.Dial9foraFortPierceexchange;dial8-1-AreaCodeforallothernumbers.Anauthorizationcodeisneededforlongdistancecalls.EmergencySatelliteCommunicationsSystem(ESATCOM)a0b.ThisisasecondalternatecommunicationspathwaytotheStateWarningPointandSt.LucieandMartinCounties.Toinitiatetransmission,liftthehandsetanddepressthe"push-to-talk"barinthehandset.Wait3-5secondstohearabeepbeforestartingtotalk.Theredlightonthephoneisapowerindicator,whenlit,powerisavailable.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:36of83ATTACHMENT4ACOMMUNICATIONSGUIDELINES(Page5of7)B.(continued)7.LocalGovernmentRadio(LGR)-CallSign:KiloNovemberGolfRomeo8-7-4(KNGR874).a.ThisisthethirdalternatecommunicationspathwaytotheStateWarningPoint.b.AbackupcommunicationsystemtotheCountiesandindirectlytotheState.Atableradio,MotorolaCommandSeries,providestwochannels,theprimaryF2(39.180MHz,StateChannel1)andthesecondaryF1(39.100MHz,StateChannel2).Channelselectioncanbemadebydepressingthe"F1/F2"button(theradioissettomonitorF2).Theradiocanbeoperatedeitherbydepressingthe"transmit"buttonontheconsoleorberemovingthehandsetanddepressingthe"push-to-talk"barinthehandset.The"xmit"lightislitduringtransmission.(Preferenceshouldbegiventousingthehandset).SatelliteTelephonea.Instructionsforuseofthesatellitetelephoneareprovidedinthephone'sbriefcase.b.ThephoneisstoredinasupplycabinetintheTSC.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:37of83ATTACHMENT4ACOMMUNICATIONSGUIDELINES(Page6of7)C.tt3AlternateStateWarninPointNotificationMethods(recommendedformat):NOTEUseofthecommercialtelephoneasanalternatenotificationmethodrequirescallbackverificationfromtheStateWarningPoint.UseofESATCOMorLocalGovernmentRadioasanalternatenotificationmethodshouldincludeacallbackverificationnumberifavailable(e.g.,cellularhone.Alternate1-CommercialphoneCalltheStateWarningPointusingthephonenumberintheSt.LuciePlantEmergencyResponseDirectory(ERD).Announce"ThisisSt.LucieUnitNuclearPlantwithanemergencydeclaration.MycallbacknumberisHangupthephoneandstandbyforthecallback.WhentheStateWarningPointgivesthego-ahead,providetheinformationfromtheStateofFloridaNotificationMessageForm.g4RequestcallbacktoverifythatStateWarningPointhasnotifiedSt.LucieandMartinCountiesandtheBureauofRadiationControl.2.Alternate2-ESATCOMHolddownthebuttononthehandsetandwait3-5secondstohearabeepbeforeyoustarttalking.Thismustbedoneeachtimeyoutalk.Announce"StateWarningPoint,thisisSt.LucieUnit,"thenreleasethebuttoninordertolisten.WhentheStateWarningPointacknowledges,announce"StateWarningPiiihiiiSi,LiUii~lifiii,pi~IWhentheStateWarningPointgivesgo-ahead,providetheinformationfromtheStateofFloridaNotificationMessageForm.Announce"St.Lucieclear"attheendoftheconversation.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:38of83C.(continued)ATTACHMENT4ACOMMUNICATIONSGUIDELINES(Page7of7)3.Alternate3-LocalGovernmentRadio(LGR)communicationtoSt.LucieandMartinCountyEmergencyOperationsCenters(EOCs)withrelaytotheStateWarningPoint.Onchannel2,contactthecountyEOCsbydepressingthetransmitbuttonandannouncing"St.LucieCountyEOC,thisisSt.LucieNuclearUnit~Over."WhenSt.LucieCountyreplies,directthemtostandbywhileyoucontactMartinCounty.Whenbothcountiesareonline,announce"MartinandSt.LucieCountyEEE,INI6i.ti~IIlitdIig~l~6t~l~ti.Itdiggfttit6tIfglidNotificationMessageForminformationwhenyouarereadytocopy.Over."Whenthecountiesgivethego-ahead,providetheinformationfromtheStateofFloridaNotificationMessageForm.Endtheconversationbyannouncing"ThisisSt.LucieUnitKNGR874,overandout."ENDOFATIACHMENT4A REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:39of83ATTACHMENT4BSAFETYFUNCTIONSEQUIPMENTSTATUS-UNIT1(Page1of4)ERDADSSF1ScreenMimicPLANTPARAMETERSREACTORPWR(WR)!oREACTORVSLLEVELloRCSPRESSURE(NR)PSIA(1500-2500)RCSPRESSURE(LR)PSIA(0-1600)PRESSURIZERLEVEL/oCETTEMPERATUREDEGFHOTLEGATEMPDEGFHOTLEG8TEMPDEGFCOLDLEGA1TEMPDEGFCOLDLEGA2TEMPDEGFCOLDLEG81TEMPDEGFCOLDLEG82TEMPDEGFLMTNGSBCOOLMRGNDEGFS/GAPRESSUREPSIGS/GALEVEL(WR)/oS/G8PRESSUREPSIGS/G8LEVEL(WR)/oCNTMTPRESS(WR)PSIGCONTAINMENTTEMPDEGFSAFEGUARDSPUMPSTATUSHPSIAHPSI8LPSIALPSI8CHRGACHRG8CHRGCCCWACCW8CCWCAFWAAFW8AFWC(ON/OFF)ON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFAUXFEEDFLOWGPMA8CBIASABIAS8MSISAMSIS8YES/NOYES/NOYES/NOYES/NOA1A28182LPSIFLOWGPMA1A28182S~IT'oLEVEL'1A28182SIT'SPRESSPSIAAiA28182SAFEGUARDSSIGNALSCNTMTCOOLERACNTMTCOOLER8CNTMTCOOLERCCNTMTCOOLERDON/OFFON/OFFON/OFFON/OFFCONTAINMENTPRESSUREPBIGLEVEL(NR)FEET((-7)TO0)LEVEL(WR)FEET((-1)TO26)TEMPERATUREATMOSPHEREDEGFSUMPDEGFCHHRMR/HRPOST/LOCAMR/HRPARTICULATECPMGASEOUSCPMHYDROGENCONCENTRATIONAANALYSER'Yo8ANAI.YSER/oCONTAINMENTCOOLERS(ON/OFF)HVE4AHVE48HVE6AHVE68HVE9AHVE98HVE10AHVE108ON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFBALANCEOFPLANTELECTRICALPLANT4.16KVA3VOLTS4.16KV83VOLTSDIESELGENERATORSD/GAVOLTSD/GAAMPSD/G8VOLTSD/G8AMPSTANKSTATUSRWTFEETCSTFEETBAMTA'/oBAMT8o/HVACSTATUS(ON/OFF)
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:40of83ATTACHMENT4BRADIOACTIVEGASEOUSSOURCETERMS-UNITI(Page2of4)ERDADSRG1ScreenMimicWINDSPEEDWINDDIRECTIONAIRTEMP10METERMPHDEGDEGF57.9METERMPHDEGDEGFDIFFTEMPDEGF/50METERCHANNELMAINSTEAMVALUEUNITSCHANNELCONTAINMENTVALUEUNITS05-01AMAINSTMMR/HR58AHIRANGER/HR05-02BMAINSTMMR/HR59BHIRANGER/HRPRESSUREPSIGCHANNEL02-0502-0702-0902-10ECCS1ALOWRANGEMIDRANGEHlRANGEFLOWVALUEUNITSCHANNELPLANTVENTuC/cc01-05LOWRANGEuC/cc01-07MIDRANGEuC/cc01-09HlRANGESCFM01-10FLOWVALUEUNITSuC/ccUC/ccUC/ccSCFMCHANNELECCS1B03-05LOWRANGE03-07MIDRANGE03-09HlRANGE03-10FLOWVALUEUNITSCHANNELuC/cc04-05uC/cc04-07uC/cc04-09SCFM04-10FUELBLDGVALUELOWRANGEMIDRANGEHlRANGEFLOWUNITSuC/ccuC/ccUC/ccSCFM REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:41of83ATTACHMENT4BRADIOACTIVEGASEOUSSOURCETERMS-UNIT2(Page3of4)ERDADSSF2ScreenMimicPLANTPARAMETERSREACTORPOWER(WR)RXVSLHEADLEVEL'/oRXVSLPLENUMLEVEL/oRCSPRESSURE(NR)PSIA(1500-2500)RCSPRESSURE(LR)PSIA(0-750)PRESSURIZERLEVEL'/oCETTEMPERATUREDEGFHOTLEGATEMPDEGFHOTLEG8TEMPDEGFCOLDLEGA1TEMPDEGFCOLDLEGA2TEMPDEGFCOLDLEG81TEMPDEGFCOLDLEG82TEMPDEGFLMTNGSBCOOLMRGNDEGFS/GAPRESSUREPSIGS/GALEVEL(WR)'/oS/G8PRESSUREPSIGS/G8LEVEL(WR)/oCNTMTPRESS(WR)PSIGCONTAINMENTTEMPDEGFSAFEGUARDSPUMPSTATUSHPSIAHPSI8LPSIALPSI8CHRGACHRG8CHRGCCCWACCW8CCWCAFWAAFW8AFWC(ON/OFF)ON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFAUFEEDFLOWGPMA8CSIASABIAS8MSISAMSIS8YES/NOYES/NOYES/NOYES/NOA1A28182LPSIFLOWGPMA1A28182~Sll'SLEVEL'1A28182SIT'SPRESSPSIAA1A28182SAFEGUARDSSIGNALSCNTMTCOOLERACNTMTCOOLER8CNTMTCOOLERCCNTMTCOOLERDON/OFFON/OFFON/OFFON/OFFCONTAINMENTPRESSUREPSIGLEVEL(NR)FEET((-7)TO0)LEVEL(WR)FEET((-1)TO26)TEMPERATUREATMOSPHEREDEGFSUMPDEGFRADIATIONLEVELCHHRMR/HRPOST/LOCAMR/HRPARTICCPMGASEOUSCPMHYDROGENCONCENTRATIONAANALYSER/8ANALYSER/oCONTAINMENTCOOLERS(ON/OFF)RWTFEETCSTFEETBAMTA/oBAMT8o/HVACSTATUS(ON/OFF)HVE4AHVE48HVE6AHVE68HVE9AHVE98HVE10AHVE108ON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFON/OFFBALANCEOFPLANTELECTRICALPLANT4.16KVA3VOLTS4.16KV83VOLTSDIESELGENERATORSD/GAVOLTSD/GAAMPSD/G8VOLTSD/G8AMPSTANKSTATUS REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:42of83ATTACHMENT4BRADIOACTIVEGASEOUSSOURCETERMS-UNIT2(Page4of4)ERDADSRG2ScreenMimicWINDSPEEDWINDDIRECTIONCURRENTTEMPDIFFTEMP10METERMPHDEGDEGFDEGF57.9METERMPHDEGDEGFCHANNELMAINSTEAMVALUEUNITSCHANNELCONTAINMENTVALUEUNITS631AMAINSTMMR/HR40AHlRANGER/HR632BMAINSTMMR/HR41BHlRANGER/HR633BACKGROUNDMR/HRPRESSUREPSIGCHANNEL601602603604ECCS2AVALUEUNITSCHANNELPLANTVENTLOWRANGEUC/cc621LOWRANGEMIDRANGEuC/cc622MIDRANGEHlRANGEUC/cc623HlRANGEEFFLUENTuC/SEC624EFFLUENTVALUEUNITSuC/ccuC/ccuC/ccuC/SECCHANNEL611612613614ECCS2BLOWRANGEMIDRANGEHlRANGEEFFLUENTVALUEUNITSuC/ccuC/ccuC/SECENDOFATTACHMENT4B REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT5TSCERDADSOPERATORCHECKLIST(Page1of2)PAGE:43of83NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofseuence.A.FACILITYACTIVATION1~RefertoSection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.B.FACILITYOPERATIONINITIALCAUTIONEnsuredataisbeingcollectedfortheaffectedunit.EachunithasredesinatedERDADSterminals.2.CheckoutERDADSterminalsanddetermineoperabilitystatus.IfERDADSisinoperableorprintoutsarenotavailable,ThenassisttheSound-poweredPhonetalkerincollectingplantparameterandradiologicaldatabycompletingAttachment4B,SafetyFunctionsEquipmentStatusandRadioactiveGaseousSourceTerms.Stepstooccurcontinuallywhilethefacilityisinoperation:a.C.CallupEPIPscreensandadditionaldataasrequested,refertoAttachment5A,ERDADSDataAcquisition.ProvidethefollowingprintoutstotheTSCAdministrativeStaff.1.SafetyFunctionsEquipmentStatus(SF1/2).2.RadioactiveGaseousSourceTerms(RG1/2).3.Otherscreensasrequested.SupportdoseassessmentbyprovidingrequesteddatafromERDADS.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:44of83B.C.ATTACHMENT5TSCERDADSOPERATORCHECKLIST(Page2of2)2.(continued)d.ObserveERDADSdataduringintervalbetweenreportprintingforsignificantchangesandtrends,reportchangestoappropriatemembersoftheTSCstaff.e.RefertoAttachment5B,ERDADSDataPoints,foradescriptionofERDADSdatapoints.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAIIpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.2.3.ERDADSsystemreturnedtopreactivationcondition.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheTSCSupervisor.Returnedpositionnotebooktostoragecabinet.ENDOFATTACHMENT5 REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:45of83I~DATAACQUISITIONATTACHMENT5AERDADSDATAACQUISITION(Page1of3)A.ERDADS-EmergencyResponseDataAcquisitionandDisplaySystem,thefollowinginformationisavailableonthedisplayscreensindicated.MeteorologicalData-Display:SMD(SiteMeteorologicalData)2.PlantParameterData-CAUTIONCertainparameters(e.g.,fanstatus)availableonUnit2areNOTavailableonUnit1.3.4.Display:intheTSC-SF(1/2)(SafetyFunctionsandEquipmentStatus)RadiologicalData-Display:RG(1/2)(RadiationGaseousSourceTerms)RBS(HealthPhysicsEvaluationScreen-containmentradiationlevelsandtrends)R11(AreaRadiationMonitors,Unit1)R21(AreaRadiationMonitors,Unit2)ChemistryData-Display:R12(S/GBlowdown,SteamJetAirEjector,Unit1)R22(S/GBlowdown,SteamJetAirEjector,Unit2)
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:46of83ATTACHMENT5AERDADSDATAACQUISITION(Page2of3)I.DATAACQUISITION(continued)A.(continued)5.Toaccessdata-80b.C.e.Press"CLEAR"Typein"PupUnit(1/2)"Press"EXEC"ute,topofscreenwillread"Unitchangeiscomplete"or"CurrentUnitissameasenteredUnit"Press"EPIP"The"PAGEUP"and"PAGEDOWN"keyswillcausethefollowingdisplaysequence:SMD-RG(1/2)-SF(1/2)-RBS-EF(1/2)-SMD6.Togodirectlytoascreen-8$Press"CLEAR"b.Typeinscreendesignation,e.g.,"RG1"c.Press"DISPLAY"B.Sound-poweredPhonetalker-TheSound-poweredPhonetalkercanbeutilizedasaprimarysourceofinformationorasanalternatemethodtoERDADS.1.Primarysource-statusoffansneededfordoseassessmentexhaustfans6,7,8,9,10,15,16and17.
REVISIONNO.:PROCEDURENo.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:47of83ATTACHMENT5AERDADSDATAACQUISITION(Page3of3)II~ERDADS-COLOR/SYMBOLCONVENTIONSColor/SmbolNumericvalueinwhiteondarkgreenbackgroundDatavalueisvalidandwithintheinstrumentrange.Numericvalueblinking(yellowonblue/redonwhite)Valuemaybeyellowonbluebackground(urgentalarm)orredonwhitebackground(criticalalarm),indicatesanalarmsettinghasbeenexceeded,thealarmmustbeacknowledgedintheControlRoom(operatorsareunabletoacknowledgeERDADSalarmsintheSimulatorControlRoom),thevaluewillcontinuetoblinkuntilacknowledged;thevaluewillcontinuetoupdate."BAD"(blueonwhite)Precededbyanumericvalueinwhiteonabluebackgroundsignifyingasuspectvalueindicatingthatoneorseveralinputstothiscompositepointis/areoutofinstrumentrange,whenallinputstothepointareoutofrangetheword"BAD"replacesthenumericvalue."FAILED"Pointisfromasingleinstrumentandthevalueisoutofrange."NODATA"PointdoesnothaveinputtoERDADS,usuallypointavailableononeunit,butnottheother.'BasedonTable4.1intheERDADSReactorOperator'sManual(8770-12058)ENDOFATTACHMENT5A REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:48of83ATTACHMENT5BERDADSDATAPOINTS(Page1of8)ThefollowingdatapointdescriptionsforSt.LuciePlantcorrespondwiththedatanormallytrackedontheplantparametersstatusboard.ConsultERDADSManual,asnecessary,forverificationofpointIDs,pointnamesordescriptioninformation.POINTDESCRIPTIONAvg.RCSTHot(HLAandHLB)(deg.F)PTIDQTA541-1/2POINTNAMETYPECALCULATIONAverageNOTESThisparameteristheaverageofthe"Aand"Bsteamgeneratorinlettemperature.Itisalsoreferredtoastheaveragehotlegtemperature.TheIndividual'Aand"B"hotlegtemperaturesarederivedbychoosingbetweencurrentnarrowandwiderangesensorvalues.Thechoicedependsonthecurrentvalues,qualitiesanddirectionoftheratesofchangeoftheinstrumentationvalues,aswellastwopairsofoverlappingswitchinglimitsandthemostrecentrangeutilized.Theoutputsfromthecalculationconsistofthechoiceofrange,theassociatedvalueandrateofchangetogetherwiththeualitofeach.RCSPressureWR(psia)QA0501-1/2RCSPressureAverageThisparameterisaReactorCoolantSystem(RCS)widerangeinstrument.ItderivedfromPressurizerPressuresignalsPT1107-2andPT110S-2whicharelinear.Thesesignalsareprocessedbyanaverageviithexpandedqualityalgorithm.Thisfunctionobtainstheaverageofallvaluesviithagoodstatus.Italsosetsthequalityoftheresultbasedonthenumberofvalueswithgoodstatus,versusthetotalnumberofinputs.Thepossiblestatusvaluesare:Greaterthan50%ofinputshavegoodstatus,resultisgood.Onlyonegoodvalueandthetotalinputsare3ormore,theresultispoor.Whentherearenogooddatavalues,buttherearesomewithpoororsuspect,theresultispoor.Theresultissuspectforallothercasesexceptallbad,inthiscasetheresultisbad.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:49of83ATTACHMENT5BERDADSDATAPOINTS(Page2of8)POINTDESCRIPTIONPTIDPOINTNAMETYPECALCULATIONNOTESRCSPressurizerLevel(%)QA0001-1/2PRZRLVLAverageThisparameterispressurizerlevel.ItisderivedfromPressurizerLevelcontrolsignalsLT1110X-2andLT1110Y-2whicharelinear.Thesetwosignalsareprocessedbyanaveragewithexpandedqualityalgorithm.Thisfunctionobtainstheaverageofallvalueswithagoodstatus.Italsosetsthequalityoftheresultbasedonthenumberofvalueswithgoodstatus,versusthetotalnumberofinputs.Thepossiblestatusvaluesare:Greaterthan50%ofallInputshavegoodstatus,resultisgood.Onlyonegoodvalueandthetotalinputsare3ormore,theresultispoor.Whentherearenogooddatavalues,buttherearesomewithpoororsuspect,theresultispoor.Theresultissuspectforallothercasesexceptallbad,inthiscasetheresultisbad.Thetopoftheheatersis73.98inchesabovethelowertocenterline.ChargingFlowtoRegenHxGPMFT2212-1/2RCSCHG/MUN/AThisparameterisreactorcoolantsystemmakeupflow.ItIsconvertedtoengineeringunitsusingalineareuation.SubcoolingMargin(deg.F)QA0005-1/2SubmarginMinimalThisparameterisderivedfromeightsubcooledvalues,TMARHEAD-A-1/2,TMARRCS-B-1/2,TMARUR-A-1/2,TMARHEAD.B-1/2,TMARCET-A-1/2TMARUR-B-1/2,TMARRCS-A-1/2andTMARCET-B-1/2,whichareprovidedbytheQualifiedSafetyParameterDisplaySystem(QSPDS).Theyareprocessedbyasignalauctioneeringminimumalgorithm.Thisfunctionfindsthehighestusabledatavalueinaspecifiedgroup.Eachdatavalueofthegroupanditsqualityisexaminedandthefollowingquantitiesareobtained:1.Lowestusabledatavalue,2.Pointnumberofthelowestusabledatavalue,3.Numberofusabledatavalues,and4.Lowestqualityoftheusabledata,Fortwoormoreusabledatavalues,theresultisthehighestusablevalueandthequalityisthelowestqualityoftheusabledata.Foronlyoneusabledatavalue,theresultissettothatvalueandthequalityispoor.Fornousabledata,thevalueoftheresultissettothehighestofallthe(bad)dataandthequalityisbad.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:50of83ATTACHMENT5BERDADSDATAPOINTS(Page3of8)POINTDESCRIPTIONAvg.CoreExitTemperature(deg.F)ReactorVesselLevel(%)PTIDQA0003-1/2Unit1:QA0004-1Unit2:RLEVH-2RLEVP-2POINTNAMETemp.CoreEx.TYPECALCULATIONAverageMinimumNOTESThisparameterisderivedfrom45Unit1detectors,or56Unit2detectorslocatedjustabovetheupperfuelalignmentplate.TheQualifiedSafetyParameterDisplaySystem(QSPDS)providesthevalues.Theyareprocessedbyanaveragewithexpandedqualityalgorithm.Thisfunctionobtainstheaverageofallvalueswithagoodstatus.Italsosetsthequalityoftheresultbasedonthenumberofvalueswithgoodstatus,versusthetotalnumberofinputs.Thepossiblestatusvaluesare:~Greaterthan50%ofallinputshavegoodstatus,resultisgood.~Onlyonegoodvalueandthetotalinputsare3ormore,theresultispoor.~Whentherearenogooddatavalues,buttherearesomewithpoororsuspect,theresultIspoor.~Theresultissuspectforallothercasesexceptallbad,Inthiscasetheresultisbad.ThereactorvessellevelforUnit1QA0004-1isdedvedfromthereactorvessellevelsRLEV-A-1andRLEV-B-1whichareprovidedbytheQualifiedSafetyParameterDisplaySystem.TheERDADSselectthelowestofthetwovalues.Foronlyonegooddatavalue,theresultissettothatvalueandthequalityispoof.ThereactorvessellevelforUnit2isdisplayedasreactorplenumlevelRLEVPB-2andreactorheadlevelRLEVHB-2whichisprovidedbythe"BsideQualifiedSafetyParameterDisplaySystem(QSPDS).ThesetwoparametersaredisplayedwithnocalculationsbeingperformedbytheERDADScomputersystem.TheQSPDSobtainsthesevaluesfromtheheatedandunheatedjunctionthermocoupleslocatedInsidethereactor.Theyarepositionedbetweentheheadanduerfuelalinmentlateinthereactorinternals.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:51of83ATTACHMENT5BERDADSDATAPOINTS(Page4of8)POINTDESCRIPTIONReactorVesselLevel%(continued)PTIDPOINTNAMETYPECALCULATIONSensorLocation('n.tofuel)Level~linmenttate~Sement'alueif~Uncovered'OTESUnit1LevelInformation:HeadandPlenumtogetherNone12345678186'/d1443/8108715/8505/8295/8195/8105/8201918141075710080614329191270Unit2LevelInformation:HeadandPlenumtogetherSensorLocation(*in.tofuel)Level~allnmenttate~Seme~n')Valueif~Uncovered'one123None45678170d/d140'li1111/8985/8745/8535/8325/8125/8522820182120192210048200100826141220
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:52of83ATTACHMENT5BERDADSDATAPOINTS(Page5of8)POINTDESCRIPTIONHPSITotalFlow(GPM)PTIDHSITTLF-1/2POINTNAMEHPSIFlowTYPECALCULATIONSumNOTESThisparametermeasurestotalHPSIflowandisderivedfromHPSIHeaderFlowsignalsFT3311-1/2,FT3321-1/2,FT3331-1/2andFT3341-1/2whicharesquareroots.Thesignalsareprocessedwithasumofinputsalgorithm.Thisfunctionobtainstheaiebraicsumofvalueswithaoodstatus.LPSITotalFlowQA0908-1/2(GPM)ContainmentTE07-3B-1/2Temp.(deg.F)LPSIFlowCntmntTempSumN/AThisparametermeasurestotalLPSIflowandIsderivedfromLPSIHeaderFlowsignalsFT3312-1/2,FT3322-1/2,FT3332-1/2andFT3342-1/2whicharesquareroots.Thesesignalsareprocessedbyanalgorithmwhichprovidesasumoftheinputs.Thisfunctionobtainsthealgebraicsumofvalueswithaoodstatus.Thisparameterisacontainmenttemperatureinstrument.Itisconvertedtoengineeringunitsusingalineareuation.ContainmentPressureWR(pslg)QA0507-1/2CntmntPressAverageThisparametermeasurescontainmentpressureandisawiderangeindicator.ItisderivedfromWideRangeContainmentPressuresignalsPT07-4A1-1/2andPT07AB1-1/2whicharelinear.Theyareprocessedbyanaveragevjiithexpandedqualityalgorithm.Thisfunctionobtainstheaverageofallvaluesviithagoodstatus.Italsosetsthequalityoftheresultbasedonthenumberofvalueswithgoodstatus,versusthetotalnumberofinputs.Thepossiblestatusvaluesare:Greaterthan50%ofallinputshavegoodstatus,resultisgood.OnlyonegoodvalueandthetotalInputsare3ormore,theresultispoor.Whentherearenogooddatavalues,buttherearesomewithpoororsuspect,theresultispoor.Theresultissuspectforallothercasesexceptallbad,Inthiscasetheresultisbad.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE;53of83ATTACHMENT5BERDADSDATAPOINTS(Page6of8)POINTDESCRIPTIONContainmentSumpLevelWR(Ft.)PTIDQA0008-1/2POINTNAMECntmntSmpWRTYPECALCULATIONMaximumNOTESThisparameterisacontainmentsumpwiderangeinstrument.ItisderivedfromContainmentSumpLevelsignalsLT07-13A-1/2andLT07-13B-1/2whicharelinear.Theyareprocessedbyasignalauctioneeringmaximumalgorithm.Thisfunctionfindsthehighestusabledatavalueinthespecifiedgroup.Eachdatavalueofthegroupanditsqualityisexaminedandthefoiloviingrulesareused.Fortwoormoreusabledatavalues,theresultisthehighestusabledatavalueandthequalityisthelowestqualityoftheusabledata.ContainmentHydrogen(%)CH2-1/2H2Conc.AverageForonlyoneusabledatavalue,theresultissettothatvalueandthequalityispoor.Fornousabledata,thevalueoftheresultissettothehighestofallthe(bad)dataandthequalityisbad.Thisparameterisacontainmenthydrogenaverageconcentrationmeasurement.ItisderivedfromHydrogenConcentrationsignalsA-HYDROGEN-1/2andB-HYDROGEN-1/2whicharelinear.Thesesignalsareprocessedbyanaveragewithexpandedqualityalgorithm.Thisfunctionobtainstheaverageofallva!uesviithagoodstatus.Italsosetsthequalityoftheresultbasedonthenumberofvalueswithgoodstatus,versusthetotalnumberofinputs.Thepossiblestatusvaluesare:~Greaterthan50%ofallInputshavegoodstatus,resultisgood.SGLevelAWR(%)SGLevelBWR(%)LT9012-1/2SGLevelALT9022-1/2SGLevelBNIANIA~Onlyonegoodvalueandthetotalinputsare3ormore,theresultisoor.Thisparameteristhe"A"steamgeneratorviiderangelovelInstrument.Itisconvertedtoengineeringunitsusingalinearequation.LTCL=LowerTapCenterUne.Thelowertapis19.5inchesabovethebottomoftheUtubes.Thisparameteristhe"B"steamgeneratorwiderangelevelInstrument.Itisconvertedtoengineeringunitsusingalinearequation.LTCL=LowerTapCenterLine.Thelowertapis19.5inchesabovethebottomoftheUtubes.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:54of83ATTACHMENT5BERDADSDATAPOINTS(Page7of8)POINTDESCRIPTIONPTIDPOINTNAMETYPECALCULATIONNOTESSGPressureA(psig)SGPressureB(pslg)QA0021-1/2SGPres./AQA0022-1/2SGPres./8RedundantSensorAlgorithmRedundantSensorAlgorthlmThisparameteristheA"steamgeneratorpressure.ItisderivedfromthreeSteamGeneratorPressureSignals,PT8013A-1/2,PT8013B-1/2andPT8013C-1/2,whicharelinear.Thesesignalsareprocessedbyaredundantsensoralgorithm.Thisfunctionobtainstheaverageofthecurrentva!uesthathaveagoodstatusandareclosetothestatisticalma'orit.ThisparameteristheB"steamgeneratorpressure.ItisderivedfromthreeSteamGeneratorPressureSignals,PT8023A-1/2,PT8023B-1/2andPT8023D-1/2,whicharelinear.Thesesignalsareprocessedbyaredundantsensoralgorithm.Thisfunctionobtainstheaverageofthecurrentvaluesthathaveagoodstatusandareclosetothestatisticalmaorit.RefuelingWaterTankAvg.Level(Ft.)RWTAL-1/2BWSTLovelAverageThisparametermeasuresrefuelingwatertanklovel.Itisderivedfromthreeinputs.TheyareLT07-2A-1/2,LT07-2B-1/2andLT07-2C-1/2.Thesepointsareprocessedbyanaverageviithexpandedqualityalgorithm.Thisfunctionobtainstheaverageofallvalueswithagoodstatus.Italsosetsthequalityoftheresultbasedonthenumberofvalueswithgoodstatus,versusthetotalnumberofinputs.Thepossiblestatusvaluesare:~Greaterthan50%ofallinputshavegoodstatus,resultisgood.~Onlyonegoodvalueandthetotalinputsare3ormore,theresultispoor.~Whentherearenogooddatavalues,buttherearesomewithpoororsuspect,theresultispoor.~Theresultissuspectforallothercasesexceptallbad,Inthiscasetheresultisbad.Tankbottomreferstozeroallons.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:55of83ATTACHMENT5BERDADSDATAPOINTS(Page8of8)POINTDESCRIPTIONPTIDPOINTNAMETYPECALCULATIONNOTESCHRRM.Unit1:Channel(R/HR)RE26-58-1(AChannel)RD26-59-1BChannel)Unit2:RIM2640-2(AChannel)RIM26P1-1BChannelCntmnt.RadMaximumThehighcontainmentradiationinstrumentsforUnit1aretheAsidemonitorRE26-58-1andthe'BsidemonitorRE26-59-1.Thesemonitorsareonlyrangecheckedandflaggedbadifoutofrange.Bothdetectorsarelocatedatthe90footcontainmentelevationandarepositionedat0and180degrees.ThehighcontainmentradiationinstrumentsforUnit2aretheA"sidemonitorRIM26<0-2andthe"BsidemonitorRIM2641-2.Thesemonitorsareonlyrangecheckedandareflaggedbadifoutofrange.Bothdetectorsarelocatedatthe90footcontainmentelevationandarepositionedat0and180degrees.ENDOFATTACHMENT5B REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT6TSCADMINISTRATIVESTAFFCHECKLIST(Page1of3)PAGE:56of83NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofseuence.A,FACILITYACTIVATIONRefertoSection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.INITIAL2.Verifyproceduresbypostingrevisionnumbersonthestatusboard.Postallprocedures(EPIP,HP,Chem.).ConsultControlCopy5intheTSCdocumentcabinetsorfollowthestepsbelowtoprintoutanEPIPlist:80C.d.e.g.InLotusNotes,clickonthePSLProceduresicon.OntheSearchlinetoolbar,clickthefarrightbutton(with2circlesandadownarrow).SelectGroupSearchfromthedropdownmenu.IntheSearchlinetype"EP"(wherethe"XX"is)~ClickSearchorhitEnter.EPIPlistisnowdisplayed(notinanyparticularorder).Toprintthelist-ClickFileSelectPrintfromthedropdownmenuSelectViewOptionsinthedialogueboxClickOK3.TelecopytheECLog,completednotificationformsandchecklists,andanyotherpertinentinformationtotheEOF.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:57of83ATTACHMENT6TSCADMINISTRATIVESTAFFCHECKLIST(Page2of3)B.FACILITYOPERATIONNOTEInformationshouldbeupdatedevery15-30minutesandnotlongerthan60minutes.Synchronizethefacilityclock(s)withERDADS.IncaseofERDADSfailure,synchronizewiththeaffectedControlRoom.2.Stepstooccurcontinuallywhilethefacilityisinoperation:80b.ObtainthefollowingERDADSdatasheets(printouts)fromtheERDADSOperator:1.SafetyFunctionsEquipmentStatus(SF1/2).2.RadioactiveGaseousSourceTerms(RG1/2).UpdatestatusboardswithnewERDADSdata.C.d.e.Requestthesound-poweredphonetalkertoobtainanyinformation/datanotprovidedbytheERDADSprintouts.Verifyalldatahasbeenaccuratelytransferredtothestatusboard.Updatethesequenceofeventsboardfollowingeachfacilitybriefingandasneeded.Providerelevantinformationconcerningitemssuchas:1.Changeinclassification.2.Significantchangeinplantcondition.3.Statusofplantsystem(s)ofconcern.4.Injuredpersonnelstatus.5.Otheritemsofrelevantinterest.g.UpdatedoseassessmentandfieldmonitoringdataasinformationisprovidedbyChemistryandHP,respectively.Makecorrections,whenidentified,bycirclingthecorrecteddata.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT6TSCADMINISTRATIVESTAFFCHECKLIST(Page3of3)PAGE:58of83B.C.2.(continued)h.Whenallstatusboardcolumns/blanksarefilled,erasethefirsttwocolumns/blanks,enternewdatawithadifferentcoloredmarkerleavingaspacebetweenthenewandtheolddata.i.ProvideanyincomingtelecopymaterialstotheTSCSupervisororasdesignatedonthecoverpage.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.2.3.Statusboardshavebeencleanedandreturnedtopreactivationcondition.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheTSCSupervisor.Returnedpositionnotebooktostoragecabinet.ENDOFATTACHMENT6 REVISIONNO.:PROCEDURENo.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT7TSCCOORDINATORWITHOSCCHECKLIST(Page1of1)PAGE:59of83NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofseuence.A.B.C.FACILITYACTIVATION1~RefertoSection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.FACILITYOPERATION1.EstablishcontactwiththeOSCCoordinatorwiththeTSC(intheOSC).2.Stepstooccurcontinuallywhilethefacilityisinoperation:a.TrackallrequestsforRe-entryTeamsusingAttachment7A,Re-entryLog.b.Communicatere-entryrequeststotheOSCCoordinatorwiththeTSCperAttachment7A,Re-entryLog.c.UpdatetheOSCStatusBoardwithRe-entryTeaminformation.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.1.ClosedoutallRe-entryTeamsenteredintheRe-entryTeamLogandthestatusboard.2.Statusboardhasbeencleanedandreturnedtopreactivationcondition.3.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheTSCSupervisor.4.Returnedpositionnotebooktostoragecabinet.ENDOFATTACHMENT7 REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:60of83ATTACHMENT7ARE-ENTRYLOG(Page1of1)TASKREQUEST(TSC)TheTSCfillsinthissectionandcommunicatestheinformationtotheOSC.0InvestigateA.Description0Repair0OtherB.*Priority:CI1(target10mins)Cl2(target20mins)CI3(target30mins)C.TSCContact:Phone:TEAMASSIGNMENT(OSC)TheOSCfillsinthissectionandcommunicatestheinformationtotheTSC.D.TeamNo:F.TimeOut:E.Re-entrySupv.:G.TimeIn:TASKREQUEST(TSC)TheTSCfillsinthissectionandcommunicatestheinformationtotheOSC.0InvestigateA.Description0Repair0OtherB.*Priority:01(target10mins)02(target20mins)CI3(target30mins)C.TSCContact:Phone:TEAMASSIGNMENT(OSC)TheOSCfillsinthissectionandcommunicatestheinformationtotheTSC.D.TeamNo:TimeOut:E.Re-entrySupv.:G.TimeIn:AssignmentofPriorities/Re-EntryTeamDispatchTargets(AssignmentofprioritiesismadebytheTSC.Thedispatchtimesaretargetsthatshouldbevigorouslypursued.)Priority1-Dispatchwithin10minutes(e.g.,fire,injury,specificOperatoractionssuchasApp.X,etc)Priority2-Dispatchwithin20minutes(e.g.,EmergencyCoordinatortoppriority,actionsrequiredtoprotectthehealthandsafetyofthepublic,etc.)Priority3-Dispatchwithin30minutes(e.g.,routinere-entry)PSL-F086EffectiveDate:06/15/01ENDOFATTACHMENT7A REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:61of83ATTACHMENT8TSCOPSCOORDINATORCHECKLIST(Page1of4)NOTE1.Thispositionisfilledbytwopersons,onelocatedintheaffectedControlRoom,theotherintheTSC.ThepositionintheControlRoomisalsoknownastheNPSCommunicator.2.Whennecessaryorappropriate,stepsofthischecklistmaybeerformedoutofseuence.A.FACILITYACTIVATIONINITIALNOTEThefirstpersontoarriveattheTSCshouldreporttotheaffectedControlRoomtorelievetheDutCallSuervisor.Fillingpositionin:2.(TSCpositiononly)RefertoSection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.FACILITYOPERATION1.Establishcommunicationswithcounterpart.2.IntheTSC,establishtheOPSConferenceBridgeasfollows:a.Obtaincontactphonenumbersfor:OPSCoordinatorintheControlRoom2.OSCOPSRe-entrySupervisor3.ProblemSolvingTeam4.Otherparticipantb.CalltheOPSCoordinatorState:"stayontheline"2.Depresstheconferencebutton REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:62of83B.2.3.4.ATTACHMENT8TSCOPSCOORDINATORCHECKLIST(Page2of4)(continued)c.CalltheOSCOPSRe-entrySupervisor1~State:"stayontheline"2.Depresstheconferencebuttond.CalltheProblemSolvingTeam1.State:"presshandsfree/mutebutton"2.Depresstheconferencebuttone.Callanyotherparticipant1.State:"stayontheline"2.Depresstheconferencebuttonf.Hailallpartiestoverifybridgesuccessfullyestablished.InitiatetheOPSLogbook.(TSConly)Stepstooccurcontinuallywhilethefacilityisinoperation:TSCa.ProvideexpertiseinplantoperationstotheEC.b.MaintaincommunicationflowbetweentheTSCandtheaffectedControlRoomconcerningstatusofoperations.c.MaintainOPSLogbook.INITIAL REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:'CTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:63of83B.4.(continued)ATTACHMENT8TSCOPSCOORDINATORCHECKLIST(Page3of4)INITIALd.SevereAccidentManagementGuidelines(SAMG)actions1.PerformevaluationsinaccordancewithADM-17.09,Invoking10CFR50.54(x),asneeded.2.Review/approveactionsasoutlinedinAttachment12B,ProblemSolvingTeamWorksheet.3.CommunicateSAMGactionstotheaffectedControlRoom(s).ControlRooma.C.d.ProvidecommunicationsassistancetotheNPS.MonitorprocedureuseandkeeptheTSCinformed.Investigatequestions/concernsasrequestedbytheTSC.Updatetheunaffectedunit'sControlRoomwithemergencystatus.e.GatherSevereAccidentManagementGuidelines(SAMG)instructions/informationfromtheTSCOPSCoordinator.1.IftheTSCisunabletotelecopy,ThenuseAttachment12B,ProblemSolvingTeamWorksheet,torecordSAMGinstructions/information.f.CommunicateSAMGactionstotheNPS.g.ProvidefeedbacktotheTSCOPSCoordinatorregardingSAMGactions.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:64of83ATTACHMENT8TSCOPSCOORDINATORCHECKLIST(Page4of4)C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.1.Phoneconnectionterminated.2.3.4.ClosedouttheOPSLogbook.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheTSCSupervisor.Returnedpositionnotebooktostoragecabinet.ENDOFATTACHMENT8 REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:65of83ATTACHMENT9TSCREACTORENGINEERCHECKLIST(Page1of3)NOTEWhennecessaryorappropriate,stepsinthischecklistmaybeperformedoutofseuence.A.FACILITYACTIVATION1~RefertoSection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.B.FACILITYOPERATION1~EstablishtheERDADSlinkwiththeNRCEmergencyResponseDataSystem(ERDS)(useAttachment9A,InitiatingandTerminatingtheERDSLink).INITIAL REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE.'6of83B.(continued)ATTACHMENT9TSCREACTORENGINEERCHECKLIST(Page2of3)INITIAL2.Stepstooccurcontinuallywhilethefacilityisinoperation:CAUTIONBeawareofthefollowingconditions.TheseEmergencyActionLevels(EALs)areassociatedwithInitiatingConditions(ICs)usedintheclassificationofemergencies(EPIP-01,ClassificationofEmergencies).TheEmergencyCoordinatorneedstoknowifanyoftheseconditionsexist.1.DoseEquivalentIodine(DEQ)l-131activitygreaterthan275IjCi/ml.2.CHHRMreadingsgreaterthan7.3E+03R/hrORgreaterthan1.46E+05R/hr.3.PostLOCAMonitorreadingsgreaterthan100mR/hrORgreaterthan1000mR/hr.4.StepincreaseinradiationmonitorreadingsinthePlantVentand/orFuelHandlingBuilding.5.Lossofsubcoolmarginresultinginsaturatedconditions.6.HighestCoreExitThermocouple(CET)percorequadrantindicatesgreaterthan10'Fsuperheator700'F.7.Damagetomorethanoneirradiatedfuelassembly.8.UncoveringofoneormoreirradiatedfuelassembliesintheSpentFuelPool.a.Monitorcriticalplantparametersforindicationsofcorestatus.C.AssistNuclearFuelspersonnelintheEOFintheassessmentofcoredamageinaccordancewithEPIP-11,CoreDamageAssessment.AssistinSevereAccidentManagementGuidelines(SAMG)activitiesasaSAMGEvaluator.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT9TSCREACTORENGINEERCHECKLISTPAGE:67of83(Page3of3)C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.2.3.Coredamageassessmentactivitiesterminated.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheTSCSupervisor.Returnedpositionnotebooktostoragecabinet.ENDOFATTACHMENT9 REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:68of83ATTACHMENT9AINITIATINGANDTERMINATINGTHEERDSLINK(Page1of2)ThisattachmentprovidestheinstructionsforinitiatingandterminatingthecommunicationslinkbetweentheSt.LucieEmergencyResponseDataAcquisitionand'isplaySystem(ERDADS)andtheNRCEmergencyResponseDataSystem(ERDS).ThiscommunicationslinkmustbeactivatednotlaterthanonehourafterdeclaringanemergencyclassofALERTorhigher.IfcommunicationscannotbeestablishedthentheacceptedmethodofdatatransmissiontotheNRCwillbethroughtheEmergencyNotificationSystem(ENS).INITIATINGtheERDScommunicationlink:AtanyTSCERDADSterminalclearthedisplayscreenbydepressingtheCLEARkey.LogontoERDADSbytypinginPSW¹¹XXXXXXXX(theXsstandforthepasswordissuedtoOperationsSupportEngineering).ThendepresstheEXECkey.ClearthescreenwiththeCLEARkeyandselectthedesiredSt.LucieUnitbytypingPUPUNITX(theXwillbeeithera1or2dependingontheunit).ThendepresstheEXECkey.4.5.6.7.ClearthescreenbydepressingtheCLEARkeyandtypeinERDanddepresstheDSPLYkey.ThiswilldisplaytheERDSlinkcontrolpictureontheterminal.DepresstheTAB+keystoplacethecursorontheINITIATEactionbarandthendepresstheENTERkey.ThedepressingoftheENTERkeywillinitiatethecommunicationslinktotheNRCERDS.AfterthecommunicationlinkwiththeNRCERDShasbeenestablishedcleartheterminalscreenbydepressingtheCLEARkeyandlogoffbytypinginPSW0anddepressingtheEXECkey.Theloggingoffoftheterminal'sscreenwillallowthatterminaltobeusedinobtaininginformationforTSCactivitieswithoutaffectingthecommunicationlinkwiththeNRCERDS.PeriodicallycheckthestatusoftheERDSlinkbytypinginHLX(theXwillbea2forUnit1or3forUnit2)anddepresstheDSPLYkey.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:69of83ATTACHMENT9AINITIATINGANDTERMINATINGTHEERDSLINK(Page2of2)NOTE~IftheblinkingmessageNOTIFYTHENRCappearsaftertheCURRENTSTATUSthenthecommunicationslinkhasbeenlostandareconnectionisnecessarywhentheNRCrequestsitthroughtheestablishedvoiceconnectionintheTSC.Ifthishappensthenitwillbenecessarytoreinitiatethecommunicationslinkbeginningwithstep1.~GenerallytheERDSlinkwillbeterminatedbytheNRC.ThefollowingstesaretobeusedifthelinkneedstobeterminatedfromtheTSC.TERMINATINGtheERDScommunicationlink:AtanyTSCERDADSterminalclearthedisplayscreenbydepressingtheCLEARkey.LogontoERDADSbytypinginPSW¹¹XXXXXXXX(theXsstandforthepasswordissuedtoOperationsSupportEngineering).ThendepresstheEXECkey.ClearthescreenwiththeCLEARkeyandselectthedesiredSt.LucieUnitbytypingPUPUNITX(theXwillbeeithera1or2dependingontheunit).ThendepresstheEXECkey.4,5.6.ClearthescreenbydepressingtheCLEARkeyandtypeinERDanddepresstheDSPLYkey.ThiswilldisplaytheERDSlinkcontrolpictureontheterminal.DepresstheTAB-keystoplacethecursorontheTERMINATEactionbarandthendepresstheENTERkey.ThedepressingoftheENTERkeywillterminatethecommunicationslinktotheNRCERDS.AfterthecommunicationlinkwiththeNRCERDShasbeenterminatedcleartheterminalscreenbydepressingtheCLEARkeyandlogoffbytypinginPSW0anddepressingtheEXECkey.ENDOFATTACHMENT9A REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:70of83A.B.ATTACHMENT10TSCCHEMISTRYSUPERVISORCHECKLIST(Page1of3)NOTEWhennecessaryorappropriate,stepsinthischecklistmaybeperformedoutofseuence.FACILITYACTIVATION1.RefertoSection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.FACILITYOPERATION1~InitiatetheChemistryLogbook.2.Stepstooccurcontinuallywhilethefacilityisinoperation:NOTEDoseassessmentshallbeaprimaryresponsibilityoftheEOFonceitbecomesoerational.INITIALC.e.Supervisedoseassessmentactivities.Reviewalldoseprojectionprintouts.AdvisetheECofdoseprojectionresults.AssisttheECinevaluatingoff-sitedoseestimatesforPARs.AssisttheTSCECAssist/Logkeeper/ECindeterminingthe"Off-siteReleaseSignificanceCategory"ascalledforontheStateNotificationForm,asnecessary.ProvidetechnicalsupporttotheOSCChemistrySupervisor.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT10TSCCHEMISTRYSUPERVISORCHECKLIST(Page2of3)PAGE:71of83B.2.(continued)CAUTIONBeawareofthefollowingconditions.TheseEmergencyActionLevels(EALs)areassociatedwithInitiatingConditions(ICs)usedintheclassificationofemergencies(EPIP-01,ClassificationofEmergencies).TheEmergencyCoordinatorneedstoknowifanyoftheseconditionsexist.1.DoseEquivalentIodine(DEQ)l-131activitygreaterthan275IjCI/ml.2.Resultofanalysisofagaseousorliquidreleaseisgreaterthanten(10)timestheODCMlimit.3.CHHRMreadingsgreaterthan7.3E+03R/hrORgreaterthan1.46E+05R/hr.4.PostLOCAMonitorreadingsgreaterthan100mR/hrORgreaterthan1000mR/hr.5.StepincreaseinradiationmonitorreadingsinthePlantVentand/orFuelHandlingBuilding.6.Off-sitedosecalculationworksheetvaluesatone(1)mileinexcessof50mrem/hr(totaldose-TEDE)or250mrem/hr(thyroiddose-CDE)foronehalf(1/2)hourOR500mrem/hr(totaldose-TEDE)or2500mrem/hr(thyroiddose-CDE)fortwo(2)minutes.7.Off-sitedosecalculationworksheetvaluesindicatesiteboundary(one(1)mile)exposurelevelshavebeenexceededasindicatedbyanyofthefollowing:a.1000mrem/hr(totaldoserate)b.1000mrem(totaldose-TEDE)c.5000mrem/hr(thyroiddoserate)d.5000mremthroiddose-CDEg.AdvisetheEConplantchemistryrelatedmatters.h.Maintainchronologicallogofactivities.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT10TSCCHEMISTRYSUPERVISORCHECKLIST(Page3of3)PAGE:72of83B.2.(continued)i.Reviewandverifyradiologicalandprotectiveactioninformationenteredonstatusboards.C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAttpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.1~Doseassessmentactivitiesterminated.2.4,ClosedouttheChemistryLogbook.Providedallpaperwork(notboundinthepositionnotebook)totheTSCSupervisor.Returnedpositionnotebooktostoragecabinet.ENDOFATTACHMENT10 REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:73of83ATTACHMENT11TSCDOSEASSESSORCHECKLIST(Page1of2)NOTEWhennecessaryorappropriate,stepsinthischecklistmaybeperformedoutofseuence.A.FACILITYACTIVATION1.RefertoSection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.B.FACILITYOPERATIONINITIALNOTE1.InitialoperatinginstructionsforuseoftheClassAModelareprovidedinEPIP-09,Off-siteDoseCalculations.2.IfthecomputerizedClassAModelisnotavailable,doseprojectionsshallbeerformedinaccordancewithEPIP-09.1.EnsureallpreviousdosecalculationpaperworkissenttotheEOF.2.EstablishcommunicationlinkwiththeEOFDoseAssessor.4.CompleteClassAModelQCCheck.Stepstooccurcontinuallywhilethefacilityisinoperation:80b.C.ObtaininputdatafortheClassAModelfromtheERDADSOperator(RG1/2Screen).ReportdoseprojectionresultstotheTSCChemistrySupervisor.CoordinatedoseassessmentwiththeEOFunlessdirectedotherwisebytheTSCChemistrySupervisor.
REVISIONNO.:PROCEDURENo.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:74of83B.4.(continued)ATTACHMENT11TSCDOSEASSESSORCHECKLIST(Page2of2)INITIALC.d.ProvidestatusboardupdateinformationtotheTSCAdministrativeStaff(useAttachment11AandAttachment11B).1~Usingcarbonpaper,makeacopyasdataisenteredintotheformineitherAttachment11Aor11B.Retaintheoriginal,providethecopytotheTSCAdministrativeStafftoupdatethestatusboards.FACILITYCLOSEOUTANDRESTORATIONNOTEAIIpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.Doseprojectionactivitiesterminated.2.EOFcommunicationslinkedterminated.3.Alldocuments,equipmentandsuppliesreturnedtopreactivationconditionand/orlocation.4.5.6.Allpaperworkcollected.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheTSCChemistrySupervisor.Returnedpositionnotebooktostoragecabinet.ENDOFATTACHMENT11 REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:75of83ATTACHMENT1'IAOFF-SITERADIOLOGlCALASSESSMENT(Page1of1)OFFSITEDOSERADIOLOGICALASSESSMENTSTATUSANDTRENDSPARAMETERDa¹ofMonthTimeofDaDownwindSectorsUnit2400HihestDownwindSectorDoseRatesDoseRate1mile2miles5miles10milesWindDirectionat10meterelevDownwindSectorWindSpeedat10meterelev60meter-10meterdeltaTStabilitClass10meterTemeraturemRem/hrmRem/hrmRem/hrmRem/hrDegreesmphDegFDeFTEDECDETEDECDETEDECDETEDECDENobleGasRelRateIodineRelRateNobleGasTotalCiIodineTotalCiContainHiRaneCi/secCi/secCiCiR/hrVentECCSAECCSBMainSteamAMainSteamBCi/secCi/secCi/secmR/hrmR/hrTEDE=TotalDoseCDE=ThyroidDoseENDOFATTACHMENT11A REVISIONNO.:PROCEDURENO.:EPIP-04REASON:ISSUEDBY:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT11BPROTECTIVEACTIONRECOMMENDATIONS(Page1of1)PROTECTIVEACTIONRECOMMENDATIONSDATE/TIMES=SHELTERE=EVACUATEPAGE:76Of83SECTOR0-2Miles2-5Miles5-10MilesNNENEENEGESESESSESSWSWWSWQNWNWNNWADDITIONALCOMMENTS:ENDOFATTACHMENT11B REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT12TSCPROBLEMSOLVINGTEAMCHECKLIST(Page1of2)PAGE:77of83NOTE1.ThischecklistappliestothefollowingProblemSolvingTeam(PST)positions:TSCPSTLeader(Engineering)TSCElecRep-PSTTSC18CRep-PSTTSCMechRep-PST(3)TSCSRORep-PST2.Whennecessaryorappropriate,stepsofthischecklistmaybeerformedoutofseuence.A.FACILITYACTIVATION1.RefertoSection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.B.FACILITYOPERATIONINITIALNOTE1.RefertotheDocumentControlIndexforalistingofTechManualsavailableintheTSC.2.ThecomputerprovidesaLANconnectionandaccesstotheTotalEuimentDatabaseEDB.Stepstooccurcontinuallywhilethefacilityisinoperation:ProblemSolvingTeamLeaderMaintaincommandandcontrolofallPSTactivities.TheformprovidedinAttachment12A,PSTActivitiesListmaybeusedbythePSTtotrackandcommunicatethestatusofPSTactivities.2.3.EnsureallPSTmembersareawareofandunderstandthestatusofequipment.MaintainhighlevelofinquiryandinvestigationbyallPSTmembers.TrackprogressofallrequestsforPSTassistance.
REVISIONNO.:PROCEDURENo.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:78of83B.ATTACHMENT12TSCPROBLEMSOLVINGTEAMCHECKLIST(Page2of2)1.a.(continued)5.Encouragedevelopmentofmultiplesuccesspaths.6.ReviewallWorksheets(Attachment12B).b.ProblemSolvingTeamMemberINITIAL1.ParticipateasamemberoftheProblemSolvingTeambyprovidingtechnicalsupportinyourareaofexpertise.2.Evaluatesystemandequipmentfailures.3.Proposemitigativeandcorrectiveaction(s)aspromptlyaspossible.4.DocumentrecommendationsonaformsimilartoAttachment12B,ProblemSolvingTeamWorksheet.5.ServeasaSevereAccidentManagementGuidelines(SAMG)Evaluator.6.ProvideallrecommendationstotheEC.C.FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.1.Returnedalldocuments,equipmentandsuppliestopreactivationconditionand/orlocation.2.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheTSCSupervisor.3.Returnedpositionnotebooktostoragecabinet.ENDOFATTACHMENT12 REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTATTACHMENT12APSTACTIVITIESLIST(Page1of1)PAGE:79of83ItemProblemDescritionProbableCausePSTRecommendationStatusENDOFATTACHMENT12A REVISIONNo.:PROCEDURENo.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:80of83TO:ATTACHMENT12BPROBLEMSOLVINGTEAMWORKSHEET(Page1of1)PST-
SUBJECT:
DATE8TIMERECEIVED:REQUEST:REQUESTER:RESPONSE:BY50.5950.54(x)SAMGVERIFIED:N/APROBLEMSOLVINGTEAMLEADER:DATE8TIME:Priority01(10min)PriorityCI2(20min)PriorityCl3(30min)PSTContact:Ph.No.:Status:Date://,Time:ENDOFATTACHMENT12B REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:81of83ATTACHMENT13TSCSECURITYSUPERVISORCHECKLIST(Page1of3)NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofseuence.A.B.FACILITYACTIVATION1.RefertoSection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.VerifythattheEnergyEncounterhasbeennotifiedoftheemergency.(consulttheERDSection3.6,othercompanynumbers,forthephonenumber)FACILITYOPERATIONEstablishaccesscontrolfortheTSC.INITIAL2.3.4.5.ContacttheControlRoomsandrequesta~cornieted"OperationsDepartmentAccountabilityAid"beforwardedtotheTSC.initiatefacilityaccountabilitybyrequestinga~cornietedcopyofAttachment3A,TSCEROShiftStaffingandAccountabilityRosterfromtheTSCSupervisor.TelecopythecompletedAttachment3A,TSCEROShiftStaffingandAccountabilityRoster,andthe"OperationsDepartmentAccountabilityAid"formstoSecurity.ContacttheEOFEmergencySecurityManager(ESM).a.Establishresponsibility/protocolfornotificationofoff-siteauthoritiesregardingthestatusofsiteevacuation.
REVISIONNO.:PROCEDURENo.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:82of83B.(continued)ATTACHMENT13TSCSECURITYSUPERVISORCHECKLIST(Page2of3)INITIAL6.UpondeclarationofaSiteAreaEmergency.a.Startaccountabilityat:b.Startsweepsat:2.3.Off-siteworkareas.WestfortyandFitnessCenter.OwnerControlledArea.a.Beachside.b.Riverside.4.On-siteandRadiationControlledArea.5.MarineResearchCenter.7.c.Accountabilitycompletedatd.SweepscompletedatStepstooccurcontinuallywhilethefacilityisinoperation:CAUTIONEnsuretheECisawareofanyactionsrequiredbytheSecurityPlane,alertoremerencdeclaration,susensionofsafeuards,etc..a.AdvisetheEConSecurityrelatedmanners.
REVISIONNO.:PROCEDURENO.:EPIP-04PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHETECHNICALSUPPORTCENTERST.LUCIEPLANTPAGE:83of83B.ATTACHMENT13TSCSECURITYSUPERVISORCHECKLIST(Page3of3)7.(continued)b.InconjunctionwiththeESM,provideliaisonfunctionbetweenlocallawenforcementandrescueagenciesandFPLforissuessuchas:INITIAL1.Bombthreatsoractsofterrorism.C.2.Memberofthepublicormediaarrivingatthesite.3.Siteegressandingress.4.Fireorrescue/medicalresponse.c.CoordinatesafeguardssuspensionwiththeESMandEC.d.Maintainsiteaccountabilityofallpersonnelthroughouttheemergency.e.FollowSecurityProcedures.FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.2.3.5.Closedoutwiththelocallawenforcementagencies,asneeded.ClosedoutSecurityLogbook.Allpaperworkcollected.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheTSCSupervisor.Returnedpositionnotebooktothestoragecabinet.ENDOFATTACHMENT13 Title:FPLST.LUCIEPLANTEMERGENCYPLANIMPLEMENTINGPROCEDURESAFETYRELATEDProcedureNo.EPIP-05CurrentRevisionNo.EffectiveDate06/15/01ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTResponsibleDepartment:EMERGENCYPREPAREDNESSKOOREVISIONSUMMARY:Revision6-Streamlinedpaperworkrequiredforre-entryteams,04/26/01)6lHMSotargets,andstreamlinedre-entrypaperworkdowntoachecklist.eR~atabREVISION5-EliminatedOSCparamedicposition,revisedre-entryguidelinesandmadeeditorialandadministrativechanges.(G.Varnes,08/08/00)REVISION4-ClarifiedroleofOPSRe-entrySupervisorperPM99-04-122.AddedguidelinesforOSCcommandandcontrolassistanceperPM99-04-143.ProvidedinstructionsforemergencyaccesstorestrictedareasperPM99-09-079.RevisedtheminimumstaffpositioninChemistrytotheOSCChemistry.Clarifiedfacilitysign-inandaccountabilityinstructions.Reinforcedinstructionsfordevelopmentofacontingencyteam.Madeeditorialchanges.(RickWalker,10/05/99)REVISION3-AddedOSCinformationservicesreppositionandresponsibilitiestoprocedureandaddededitorialchanges.(J.R.Walker,3/2/99)Revision0Revision6FRGReviewDate12/15/97FRGReviewDate04/26/01ApprovedByJ.ScarolaPlantGeneralManagerApprovedByR.G.WestPlantGeneralManagerN/ADesignatedApproverN/ADesignatedApprover(MinorCorrection)ApprovalDate12/15/97ApprovalDate04/26/01SOPSDATEDOCTPRocEDUREDOCNEPIP-05sYsCOMcoMPLETEDITM6 3c REVISIONNO.:PROCEDURENO.:EPIP-05SECTION1.0PURPOSE.PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTTABLEOFCONTENTSPAGE:2of52PAGE
2.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTS.......63.0RESPONSIBILITIES4.0DEFINITIONS5.0INSTRUCTIONSATTACHMENTS.10ATTACHMENT1OSCEMERGENCYRESPONSEORGANIZATIONANDSHIFTSTAFFING.ATTACHMENT2OSCSUPERVISORCHECKLISTATTACHMENT2AOSCEROSHIFTSTAFFINGANDACCOUNTABILITYROSTER.ATTACHMENT2BOSCMINIMUMSTAFFINGATTACHMENT2CRE-ENTRYGUIDELINES.~ATTACHMENT2DBRIEFINGGUIDELINES.12.13.17.2122.25ATTACHMENT2EGUIDELINESFORRELOCATIONOFTHEOSC.....ATTACHMENT2FOSCFACILITYBRIEFINGSATTACHMENT3OSCCOORDINATORWITHTSCCHECKLIST.....ATTACHMENT3ARE-ENTRYLOG..~~......2628....29.31ATTACHMENT4OSCADMINISTRATIVETECH/LOGKEEPERCHECKLIST...32ATTACHMENT4ALOGKEEPINGANDSTATUSBOARDS.34 REVISIONNO.:PROCEDURENO.:EPIP-05SECTIONPROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTTABLEOFCONTENTS(continued)PAGE:3of52PAGEATTACHMENTS(continued)ATTACHMENT5OSCRE-ENTRYSUPERVISORCHECKLIST...ATTACHMENT5ARE-ENTRYTEAMFORM.ATTACHMENT5BRE-ENTRYTEAMGUIDELINESATTACHMENT6OSCRE-ENTRYFOREMANCHECKLIST.....ATTACHMENT7OSCDEPARTMENTALREPSCHECKLISTATTACHMENT7AROOM2200GUIDELINESATTACHMENT7BROOM2200SETUP.ATTACHMENT8OSCSECURITYCHECKLIST.......35.39.40.41.43~~~~~~46..49.50 REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:4of521.0PURPOSE1.1DiscussionThisprocedureprovidesinstructionsforactivationandoperationoftheOperationalSupportCenter.ThisprocedurealsoprovidesinstructionsfortheselectionanddeploymentofRe-entryTeams.1.2LocationandDescriptionTheOSCislocatedonthesecondflooroftheSouthServiceBuildinginconferenceroom2200andadjoiningroom2300.Amplespaceisavailablefortheassemblyofauxiliaryoperators,HeathPhysicstechnicians,Maintenancepersonnel,andotherpersonnelneededforemergencyresponse.Duetopotentialhabitabilityconcerns,alternatelocationscapableofsupportingOSCoperationshavebeenidentifiedasfollows:1.NorthServiceBuilding,conferenceareaormaintenanceshops2.BlowdownBuilding3.UnaffectedReactorAuxiliaryBuilding(RAB)1.3OSCFunctionsMandatoryFunctionsA.ProvidearesourcepoolofpersonneltoassisttheControlRoomandTSCinaccidentassessmentandmitigation.B.RespondtorequestsforRe-entryTeams.C.MaintainradiologicalexposurecontrolsinaccordancewiththeHP-200seriesprocedures.2.AdditionalFunctionsA.ProvidetheinterfacewiththeOff-siteAssemblyArea.B.Serveasaccesscontrolpointfollowingsiteevacuation.
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:5of521.4MinimumStaffing1.ThefollowingisthelistoftheminimumpositionsneededforOSCoperation:~OSCSupervisor~OSCChemist~OSCHPTechnician(12)~OSCElectrician(2)~OSCMechanic(2)~OSCl8CSpecialist1.5g2ActivationActivationoftheOSCistheresponsibilityoftheEmergencyCoordinator(EC)andisrequiredforanAlertorhigherdeclaredemergency.ArrangementshavebeenmadetostafftheOSCinatimelymanner.1.6OperationsTheOSChassufficientspaceavailableandradiationprotectionequipmentandothersuppliestosupportemergencyresponsepersonnelconductingre-entryactivities.TheOSChasthecapabilitytoprovide24hourcontinuousoperation,asnecessary.InitialworkactivitiesdirectedbytheOSC,attheAlertLevel,areconsideredpre-re-entryandcertainaspectsofthisproceduremayberelaxed(e.g.,HPcoverage).Followingasiteevacuationorder(evacuationoftheOwnerControlledArea)orifradiologicalconditionsexistoutsidetheRadiationControlledArea,allprovisionsofthisprocedurearerequiredforre-entryintoaffectedareas.
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:6of5
22.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTSNOTEOneormoreofthefollowingsymbolsmaybeusedinthisprocedure:gIndicatesaRegulatorycommitmentmadebyTechnicalSpecifications,ConditionofLicense,Audit,LER,Bulletin,OperatingExperience,etc.andshallNOTberevisedwithoutFacilityReviewGroupreviewandPlantGeneralManagerapproval.Indicatesamanagementdirective,vendorrecommendation,plantpracticeorothernon-regulatorycommitmentthatshouldNOTberevisedwithoutconsultationwiththeplantstaff.'PIndicatesastethatreuiresasinoffonanattachment.2.1References1.g~St.LuciePlantTechnicalSpecificationsUnit1andUnit2(Section6.10.1)2.St.LuciePlantUpdatedFinalSafetyAnalysisReport(UFSAR)Unit1andUnit23.$2St.LuciePlantRadiologicalEmergencyPlan(E-Plan)4.$3St.LuciePlantTopicalQualityAssuranceReport(TQAR)5.E-PlanImplementingProcedures(EPIP00-13)6.HP-200SeriesProcedures7.ADM-17.09,Invoking10CFR50.54(x)8.St.LuciePlantEmergencyResponseDirectory(ERD)9.QI-17-PSL-1,QualityAssuranceRecords10.FitnessforDutyRule,10CFR26 REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:,ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:7of522.2RecordsRequired1.Thefollowingshallberetainedfollowingaplantemergency~Checklistsandpaperworkgeneratedperthisprocedure.~Logbooksmaintainedduringtheplantemergency.2.g~RecordedinformationshallbeforwardedtoEmergencyPlanningfollowingtheevent,forreviewandarchivalinaccordancewithTechnicalSpecification6.10.1andQI-17-PSL-1.2.3CommitmentDocumentsPMAIPM97-04-142,TrainingDrillCritique1/24/97(Definitionofcontingencyteamandfullstaffingguidance).2.3.4,5.6.7.PMAIPM98-04-144,EvaluatedExerciseCritique3/18/98(EstablishthresholddoserateforOSCrelocation).tt3PMAIPM98-09-006(ControlofNLOsUnderE-Plan)'tt4PMAIPM99-04-122(OpsRe-entrySupervisorRole)PMAIPM99-04-143(OSCCommandandControlAssistance)PMAIPM99-09-079(HotToolRoomAccessDuringanEmergency)CR01-0078,OSCRe-entryTeamImprovements REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:8of523.0RESPONSIBILITIES3.1OSCSupervisor1~ProvidescommandandcontrolofOSCactivities.2.CoordinatesactivitiestoensureadequatesupporttotheTSC/EC.3.EnsuresthatallRe-entryTeamsareadequatelybriefedpriortoleavingtheOSCandthoroughlydebriefedupontheirreturn.4.Ensurescommunicationsflowismaintainedwithinthefacility,withtheRe-entryTeams,andwiththeTSC.5.Coordinatesfacilitybriefings.6.ArrangesforlongtermoperationoftheOSC.3.2OSCCoordinatorwithTSC1.ServesasthecoordinatorwiththeTSCforRe-entryTeamrequests.2.Logsandtracksre-entryactivities.3.KeepstheOSCSupervisorabreastoftheemergencyconditionsandplantstatus.3.3OSCRe-entrySupervisorNOTE~EachofthefollowingareashasaRe-entrySupervisor:(1)MechanicalMaintenance,(2)ElectricalMaintenance,(3)l&CMaintenance,(4)Operations,(5)Chemistry,and(6)HealthPhysics.~ResponsibilitiesfortheHealthPhysicsRe-entrySupervisor(HPOSC)areprovidedinHP-200,HealthPhysicsEmergencyOrganization.2.3.4.EnsuresdepartmentalEmergencyResponseOrganization(ERO)personnelareavailableforre-entryactivities.AssiststheOSCSupervisorinselectionofRe-entryTeammembers.Providestaskspecificbriefingstotheirdepartmentalre-entrypersonnel.ConductsRe-entryTeamdebriefings.
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:9of523.4OSCDepartmentalRepresentativeNOTEThefollowingdepartmentshaverepresentativesintheOSC:(1)NuclearMaterialsManagement(NMM),(2)Safety,(3)ProtectionandControl,4Securitand5InformationServices.1.ProvidesinputtotheOSCSupervisor,asrequestedinsupportofre-entryoperations.2.Participatesinre-entries,asneeded.4.0DEFINITIONS4.1FacilityStatus4.24.31.Activation-therequesttostaffandestablishanEmergencyResponseFacility(ERF).2.Operational=-whensufficientpersonnel(i.e.,minimumstaff)areavailabletoaccomplishthemandatoryfunctionofconductofre-entryactivities.3.FullyStaffed-thecomplementofpersonnelispresentinthefacility.FPLEmergencyRecallSystem(ERS)-thecall-outsystemusedasameansofoff-hourscall-out,asdescribedinEPIP-03,EmergencyResponseOrganization/StaffAugmentation.Re-entry-accesstoareaswhereevacuation(localorsite)hasbeenorderedconstitutesare-entry.Re-entryintoanevacuatedareaisauthorizedonlybytheEC.4.44.5Re-entryTeam-agroupofqualifiedpersonnelwhowillenteranevacuatedareaundertheauthorizationoftheECtoaccomplishanassignedtask(e.g.,repairdamagecontrol,rescue,etc.).TheinitialRe-entryTeamshallconsistofatleasttwoqualifiedpersons,oneofwhomshallbeanOSCHealthPhysicsTechnician(HPT).Videolink-aclosedcircuitaudio/visualcommunicationslinkoriginatingintheTSCwithfeedstotheOSCandtheEOFallowingtheECbriefingstobeavailableinalltheEmergencyResponseFacilities(ERFs).
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:10of525.0INSTRUCTIONSNOTE~ThissectionprovidesgeneralinformationandinstructionsforallOSCresponders.~Positionspecificchecklistsareincludedasattachmentstothisprocedure.~IndividualsspecificallydesignatedasmembersoftheOSCEmergencyResponseOrganization(ERO)areidentifiedintheERD.5.1Whennotified,OSCemergencyrespondersaretoreporttothefacilityasquicklyaspossible.5.2Uponarrivalatthefacility,eachOSCrespondershouldperformthefollowing:Sign-ininstructions:2.3.A.Personsworkinginroom2300(supervisors'rea)oftheOSCshouldsigninonthestatusboardonthesouthwallinthespacecorrespondingtotheirposition.B.AllOSCRe-entrySupervisorsshouldensurethatthenamesoftheirdepartment'sRe-entryTeammembersandforemanaresignedinonthestatusboardinRoom2300.C.TheOSCAdministrativeTech/LogkeepershouldensurethatallpersonnelinbothRooms2200and2300aresignedinonthestatusboardandthatthisinformationconcurswithAttachment2A,OSCEROShiftStaffingandAccountabilityRoster.Obtaina"Player"badgeandplaceyourname(andpositiontitle,ifnecessary)onthebadgewithadryerasemarkerorinanyothernon-permanentmanner.Obtainspecificpositionnotebook(ifapplicable)withproceduralchecklists,formsandinstructions.4.Makeyourworkstation/locationoperational,asnecessary.5.6.NotifyyoursupervisorortheOSCSupervisorofyourreadinessstatus.AssistinestablishingaccountabilitybysigninginonaformsimilartoAttachment2A,OSCEROShiftStaffingandAccountabilityRoster.
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:11of525.3g3Onlycontrolledcopiesofnuclearsafety-relatedprocedures,drawings,andotheravailableplantinformationshallbeused.Non-controlleddocumentsordrawingsshouldbeverifiedwithacontrolledcopypriortouseintheOSC.5.4Duringfacilitybriefings,stopwhatyou'edoing,payattention,andcontributeasrequested.5.5Uponterminationoftheevent:2.AllOSCpersonnelshouldreturntheirworkstations/locationstoanormalstateandassistinrestoringthefacilitytoareadycondition.AllOSCpersonnelshouldcollectallsignificantinformationanddocumentation,suchasnotesandcompleteddatasheets(notboundinpositionnotebooks)andforwardthismaterialtotheOSCSupervisor.
REVISIONNO.:PROCEDURETITLE:PAGE:PROCEDURENO.:EPIP-05ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANT12of52ATTACHMENT1OSCEMERGENCYRESPONSEORGANIZATIONANDSHIFTSTAFFING(Page1of1)OSCSUPERVISORTSC1OSCCoordinatort--"-CoordinatorIwithOSCJwithTSC(LocatedhtheTSC)OSCAdmin.Tech1Log)teeper(2)159OSCllP173OSCOPS100OSCDostnesyTesta170FietdMon.TeamDrher(3);151OSCHPTech(12)~(0h33Metrics)0(0Morest00Metrics)'soosoohemtst(3)0(1ln00~)I100OSCNMMStallRep.105OSCOn4hnSeomty170OSCSatstrRep.174oscpros5ControlRep.152OSCElachcat153OSCldoR150OSCBaCnMCNet101OSCEtectnoanSt)~(1h30Misses)0(1Morein00Mraoes)SeeNote1102OSCMernaiac(3)10(2h00araartes)SeeNote2)175OSClaCShopSpeevvisrx103osctdcspecsasst(3)~(1h30Msanes)(See~3)fpipsrKPPv)5raar<GAutodiaterpositionnumbersareSatedwilhposidonsees.~30minuteresponsegoal.perNUREG0654,TaSe8-1o60minuteresponsegoal,psrNVREG0654,TableB.tNote1.Minimumsta5ngrequirementsmaybeFdedbyBectricalReentrySupervisor,ChieforBtc(c'ciarLNots2.MinimumStatfatgrsqt4rsmentsmaybe52edbyMechaniadResnuySupeniisor.ForemanorMechanic.Note3.MinimumSta5ngrequirementsmaybe65edbylaCReentrySupervisor.ShopSupervisororlaCSecc'afr~lnrficatesmiamumsta5ngosstionsthatmustbe55edInordertodedarsthebtcRityoperationaL REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:13of52ATTACHMENT2OSCSUPERVISORCHECKLIST(Page1of4)NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofseuence.A.FACILITYACTIVATION1.Refertosection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.DetermineoperationalreadinessoftheOSCbyverifyingthefollowing:a.CommunicationsestablishedwiththeTSC.b.Minimumstaffavailable(useAttachment2A,OSCEROShiftStaffingandAccountabilityRosterorrefertothesign.inboard).c.Communicationsequipmentandothersuppliesareavailableandreadyforuse.d.EnsureRoom2200setupisunderway.IftheOSCSafetyRepisnotavailable,thenreassigntheresponsibility.e.Minimumstaffpreparedtoaccomplishmandatoryfacilityfunctions.3.IfStep2aboveissatisfied,ThendeclarethefacilityoperationalatINITIAL4.NotifiedtheEC/TSCSupervisorthattheOSCisoperational.
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT2OSCSUPERVISORCHECKLIST(Page2of4)PAGE:14of52B.FACILITYOPERATIONINITIALNOTEg~UnlessauthorizedbytheEC,facilitystaffingshouldbeinaccordancewithAttachment2A,OSCEROShiftStaffinandAccountabilitRoster.1.OSCfullystaffed.2.Instructpersonneltoverifytheirpositionnotebookproceduresagainstthepostedrevisionnumber.3.gqDirecttheHPOSCtoidentifyandpreparearepresentativefromHPandeachmaintenancedisciplineforarapidresponsecontingencyteam.4.InstructtheOSCAdministrativeTech/LogkeepertoinitiatetheOSCLogbook.5.Establishwhatteam(s)orindividual(s)isknowntobeworkingintheplant,thetask/job,andthecommunicationsmethod/controllingfacility.6.g6Identifythenecessityandmeansforprovidingaccesstoalltoolrooms(includingtheHotToolRoom)andanyotherareawithrestrictedaccess.7.ObtainfoodandwatersupplyfortheOSC.8.Arrangeforlongtermstaffing(useAttachment2A,OSCEROShiftStaffingandAccountabilityRoster).
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:15of52ATTACHMENT2OSCSUPERVISORCHECKLIST(Page3of4)B.(continued)INITIALCAUTIONTheOSCaffordslimitedprotectionagainstareleaseofradioactivematerial.Duringthetimethataradioactivereleaseisoccurring,thehabitabilityoftheOSCistobemonitored.Ameasureddoserateof50mrem/hr,inthefacility,isestablishedasthethresholdforrelocationoftheOSC.9.Ifnecessary,initiatestepsforrelocationoftheOSC(useAttachment2E,GuidelinesforRelocationoftheOSC).10.Stepstooccurcontinuallywhilethefacilityisinoperation:a.Overseecommunicationsb.Maintainlownoiselevelinthefacilityc.Conductfacilitybriefings(useAttachment2F,OSCFacilityBriefings).d.Ensureemergencystatusandplantconditionsareroutinelyupdated.(Thevideolinkmaybeusedforthispurpose.)Re-entryChecklist-WhenrequestedbytheOSCCoordinatorwiththeTSC,completethefollowinginresponsetoarequestforaRe-entryTeam:1)ReviewAttachment2C,Re-entryGuidelines,tothisattachmentasnecessary.2)CompletetheTeamAssignmentsectionofAttachment3A,Re-entryLog(lettersD&Epriortoteamdispatch).3)SelectthemostappropriateRe-entrySupervisorbasedonthenatureofthetask.
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:'ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:16of52ATTACHMENT2OSCSUPERVISORCHECKLIST(Page4of4)B.10.e.(continued)4)AssigncompletionofPartsI,IIandIIIofAttachment5A,Re-entryTeamForm,tothechosenRe-entrySupervisor.5)DirecttheHPOSCtoassistinteamdevelopmentbysatisfyingtherequirementsofHP203.1,EvacuatedAreaRe-entryChecklist,inHP-203,PersonnelAccessControlDuringEmergencies.6)ReviewAttachment2D,BriefingGuidelines,tothisprocedure,asnecessary.7)VerifyRe-entryTeampreparednesspriortodispatch.FACILITYCLOSEOUTANDRESTORATIONINITIALy7CDNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.1.AllRe-entryTeamsareloggedbackinandaccountedfor.2.Allfacilityactivitiesclosedout.3.Allequipmentandsuppliesreturnedtopreactivationconditionand/orlocation.4.Allpaperworkcollected.5.ClosedouttheOSCLogbook.6.Returnedpositionnotebooktostorageshelf.7.Providedallcompletedpaperwork(notboundinpositionnotebooks)toEmergencyPlanning.
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:17of52ATTACHMENT2AOSCEROSHIFTSTAFFINGANDACCOUNTABILITYROSTER(Page1of4)Shift'Hours:ToPOSITION(Minimumstaffinbold)OSCHPSupervisor:OSCHPTech:OSCHPTech:OSCHPTech:OSCHPTech:OSCHPTech:OSCHPTech:OSCHPTech:OSCHPTech:OSCHPTech:OSCHPTech:OSCHPTech:OSCHPTech:OSCDosimetryTech:FieldMonTeamDriver:FieldMonTeamDriver:FieldMonTeamDriver:NAMEBADGENO.
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:18of52ATTACHMENT2AOSCEROSHIFTSTAFFINGANDACCOUNTABILITYROSTER(Page2of4)POSITIONOSCl8CRe-entrySupv:OSCl8CShopSupervisor:OSCl8CSpecialist:OSCl8CSpecialist:OSCl&CSpecialist:OSCMechRe-entrySupv:OSCMechanicalForeman:OSCMechanic:OSCMechanic:OSCMechanic:OSCElecRe-entrySupv:OSCElectricalChief:OSCElectrician:OSCElectrician:OSCElectrician:NAMEBADGENO.
REVISIONNO.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:19of52ATTACHMENT2AOSCEROSHIFTSTAFFINGANDACCOUNTABILITYROSTER(Page3of4)POSITIONOSCSupervisor:OSCCoordinatorwithTSC:OSCChemistrySupv.:OSCChemist:OSCChemist:OSCChemist:OSCOn-ShiftSecurity:OSCOn-ShiftSecurity:OSCOn-ShiftSecurity:OSCOPSRe-entrySupv:OSCProtandControlRep:OSCNMMStaffRep:OSCSafetyRep:OSCInformationServicesRep:OSCAdminTech/Logkeeper:OSCAdminTech/Logkeeper:AssemblyAreaSupervisor:NAMEBADGENO.
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:20of52ATTACHMENT2AOSCEROSHIFTSTAFFINGANDACCOUNTABILITYROSTER(Page4of4)POSITIONOther:NAMEBADGENO.'Longtermstaffing,refertotheSt.LuciePlantEmergencyResponseDirectory(ERD)forpositionalternates.RefertoAttachment2Bfortemporaryalternatesforminimumstaffpositions.Positionfillsthefollowingpositions:a.TSCHPSurveys1.Unit1ControlRoom/TSC2.Unit2ControlRoom3.OSC4.AccessControlb.HPFieldTeams1.RedTeam2.OrangeTeam3.BlueTeam REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:21of52ATTACHMENT28OSCMINIMUMSTAFFING(Page1of1)MajorFunctionalArea'ositionTitleandIDNo.'inPositionQualifications/TemoraAlternateHealthPhysicsTechnicianOSCHPTech,15112MemberoftheHealthPhysics
DeartmentRad/ChemTechnicianElectricalMaintenanceMechanicalMaintenance/Radwaste0eratorl&CTechnicianFacilityCommandandControlOSCChemist,
160OSCElectrician,161OSCMechanic,162OSCl&CSpecialist,163OSCSupervisor,1571MemberoftheChemistDeartmentElectricalMaintenanceJourneymanorChieforSuervisorMechanicalMaintenanceJourneymanorForemanorSupervisorI&CMaintenanceSpecialistorSuervisor1OSCCoordinatorwithTSC1Thisfunction(s)maybeaccomplishedduringthefirst75minutesofanemergencybyanindividual(s)meetingthecorrespondinglistedqualifications.TheseEmergencyResponseOrganization(ERO)positionswereestablishedtoaccomplishtheindicatedfunction(s).
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:22of52ATTACHMENT2CRE-ENTRYGUIDELINES(Page1of3)CAUTIONAsspecifiedinADM-17.09,Invoking10CFR50.54(x),theEmergencyCoordinator(EC)may(withtheconcurrenceofalicensedsenioroperator)waivere-entryrequirementstoplacetheplantinasafeshutdownconditionormitigatearelease,ifthisimmediateactionisneededtoprotectthehealthandsafetoftheublic.1.PriortoevacuationandwiththeOperationalSupportCenter(OSC)NOToperational.Re-entryguidelinesdonotapply.2.PriortoevacuationandwiththeOSCoperational.a.$3OperatorsinthefieldshouldreturntotheControlRoomsandobtainanElectronicPersonalDosimeter(EPD)fromtheHealthPhysicsEmergencyKitpriortoreturningtofield.b.SinceteamsmaybedispatchedfromtheOSCpriortoevacuationofanyplantareas,theOSCSupervisorandHealthPhysicsSupervisorintheOSC(HPOSC)shouldevaluatetheeventinprogressanddeterminethemostlikelytrendsinradiologicalconditions.Iftheeventislikelytoresultinevacuation(s),duetoradiologicalconcerns,theteamsshouldbedressed,equipped,andbriefed,similarlytoRe-entryTeams.EvacuationorderedandwiththeOSCNOToperational.Operatoractionsinthefieldmustbeviewedasre-entryactivities.OperatorsshallreturntotheControlRoomsfollowingtheevacuationorder.OperatorsshallobtainanElectronicPersonalDosimeter(EPD)fromtheHealthPhysicsEmergencyKit,ifnotdonepreviously.Re-entryintotheplantrequires:a.TheEC(initiallytheNPS)authorizetheentry.b.Maintenanceofappropriateradiologicalandsafetymeasures.c.Trackingthewhereaboutsoftheteam.
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:23of52ATTACHMENT2CRE-ENTRYGUIDELINES(Page2of3)EvacuationorderedandwiththeOSCoperationala.NLOs,frombothUnits,aretoreporttotheOSConceitgoesoperational~b.Allfieldactivitiesarere-entriesandshallbecoordinatedandcontrolledbytheOSC.Re-entryintoanevacuatedareashallbemadeonlywhenauthorizedbytheECandunderthedirectionoftheTSCHPSupervisor(TSCHPS)andtheHPOSCforoneormoreofthefollowingreasons:1)Toascertainthatallpersonnelwhowereintheaffectedareahavebeenevacuatedandtosearchforunaccountedforpersonnel.2)Toassistinevacuatinginjuredorincapacitatedpersonnelfromtheaffectedarea.3)Toperformoperationswhichmitigatetheeffectoftheemergencyorhazardouscondition.4)Todeterminethenatureandextentoftheemergencyand/orradiologicalconditions.5)Toestablishdefinitepersonnelexclusionareaboundaries.
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:24of525.GeneralConsiderationATTACHMENT2CRE-ENTRYGUIDELINES(Page3of3)a.TheRe-entryTeammembersshouldbeselectedbasedonappropriatequalificationsrelevanttothepurposefortheentry.b.ARe-entryTeamshallconsistofatleasttwoqualifiedpersons,oneofwhomshallbeknowledgeableinHealthPhysicsprocedures.c.Themostqualified(relativetotheentry)personshouldbeselectedtoserveastheRe-entryTeamLeader.He/sheshouldbefullybriefedconcerningthenatureoftheemergencyandtheexpectationsfortheentry.d.AllRe-entryTeammembersshallwearprotectiveclothing,dosimeters,respiratorydevices,andotherprotectivedevicesasspecifiedbytheHPOSC.etbAcontingencyRe-entryTeamshouldbedevelopedconsistingofrepresentativesfromeachofthemaintenancedisciplinesandHealthPhysics.Thisteamanticipatestheneedforahighpriority,rapidresponserequestfromtheEC/TSC.
REVISIONNO.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:25of52ATTACHMENT2DBRIEFINGGUIDELINES(Page1of1)PRE-ENTRY1.TheRe-entryTeamFormtakestheplaceofaNuclearPlantWorkOrder(NPWO)package,therefore,carefuldocumentationisrequired.2.EnsurethattheRe-entryTeammembersareinstructedastowhatisrequiredofthemduringtheentrybytheassignedRe-entrySupervisor.3.EnsurethattheRe-entryTeammembersarebriefedconcerningthenatureoftheemergencyandthepossibleradiationhazardspresentbytheHPOSC.4.VerifythattheRe-entryTeamunderstandsthattheyshouldnotdeviatefromtheplannedrouteandtask,unlessduetounanticipatedcircumstancessuchasrescue,performinganoperationwhichwouldminimizetheemergencycondition,etc.andonlyafteracknowledgementfromtheOSC.5.VerifythattheRe-entryTeamunderstandsthatifthemonitoreddoseratesencounteredduringtheentryexceedthelimitssetbytheHPOSCthattheTeamshouldreturntotheOSCor,ataminimum,movetoanareaoflowbackgroundandreviewconditionswiththeOSC.6.IfaRe-entryTeamistobeassignedaneworadditionaltaskwhilestillinthefield,PartII,TaskAssessment,ofAttachment5A,Re-entryTeamForm,mustbere-evaluatedbyanappropriateRe-entrySupervisorandtheHPOSCconsulted,priortoprovidingafieldbriefing.POSTENTRY1.EvaluatethesuccessoftheRe-entryTeamincompletingthere-entrytask.2.EnsurethatPartV,-TeamWorkReport,oftheRe-entryTeamForm(Attachment5A)iscompletedbytheRe-entryTeamfordocumentation.
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:26of52ATTACHMENT2EGUIDELINESFORRELOCATIONOFTHEOSC(Page1of2)A.OSCSupervisorInconjunctionwiththeEmergencyCoordinatorandtheTSCHPSupervisor,obtainapprovaltorelocatetheOSCtooneofthefollowinglocations:(notinanypriority)a.NorthServiceBuilding,conferenceareaormaintenanceshopsb.BlowdownBuildingc.UnaffectedReactorAuxiliaryBuilding(RAB)d.Otherlocationdeemedappropriate2.Organizethreerelocationteamsasfollows:a.SETUPTEAMtopreparethealternateOSClocation.b.EQUIPMENTANDSUPPLYTEAMtoarrangeforandtransportequipmenttothealternateOSClocation.c.TURNOVERTEAMtomaintaincontinuitywiththeTSCandcommunicationswiththeSetUpTeam.EnsurethatcommunicationsareestablishedandcheckedatthealternateOSC.4.NotifytheTSCandEmergencyCoordinatorthatthealternateOSCisoperationalandtheprimaryOSChasbeenshutdown.MaintenanceRe-entrySupervisors1.Identifytoolsandequipmentfortransfer.2.Makevehiclesavailabletotransportequipment.3.MaintaincommunicationswithRe-entryTeams.
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:27of52ATTACHMENT2EGUIDELINESFORRELOCATIONOFTHEOSC(Page2of2)C.HPandChemistry1.Developarelocationbriefingregardingradiologicalconditionsandtravelroute.2.ChemistryassistHPingatheringEmergencyKitequipment,dosimetry,andexposurerecordsandpreparefortransport.3.Atthenewlocation,reestablish:a.Accesscontrolb.Habitabilitysurveysc.DeconlocationD.Security1.Reestablishaccountabilityatthenewlocation.2.EnsurethatthealternatelocationisidentifiedtoSecurityroadblocks.AdminTechandLogkeeper1.CreateanewlayoutfortheOSCinthealternatelocation,asnecessary.2.CreateanewcalllistofOSCphonenumbersinthealternatelocation.a.Aminimumoften(10)phonelinesshouldbeidentified,includingonelineforatelecopymachine,ifamachineisavailable.1)Radiochannelsmayneedtobesubstitutedformissingphonelines.Ensureallstatusboardinformationisrecordedandtransferred.
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:28of52ATTACHMENT2FOSCFACILITYBRIEFINGS(Page1of1)A.GENERALGUIDELINES1.ConductedbytheOSCSupervisororhis/herdesignee.2.Establishafrequency(e.g.,every30minutesordirectlyfollowingtheECportionoftheTSCbriefingsviathe"Videolink").3.Setcriteria(i.e.,attendance,noiseandactivitylevel,circulationofinformation).GENERALFORMAT-thefollowinginformationshouldbeincludedinfacilitybriefings.1.Timeofthebriefing2.Currentemergencyclassification3.Plantstatus(affectedUnit,unaffectedUnit)4.Radiologicalconditions(e.g.,releaseinprogress,contaminatedareas,etc.)5.Statusofprotectiveactions(e.g.,siteevacuation,actionsunderwaybythepublic,etc.)6.Statusofactivitiesunderwayinthefacility7.Requestinput/updateinformationfromotherrepresentatives(e.g.,OPS,HP,Chem,Maintenance,Engineering,Security,etc.)8.Majoractivity(s)underwayinotherfacilities(e.g.,notifications,fieldmonitoring,doseassessment,etc.)9.Concernsorquestions REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:29of52ATTACHMENT3OSCCOORDINATORWITHTSCCHECKLIST(Page1of2)NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofseuence.A.B.FACILITYACTIVATION1.Refertosection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.EstablishcommunicationlinkwiththeTSCCoordinatorwithOSC(intheTSC).3.SynchronizeOSCclockswiththeTSC.FACILITYOPERATIONStepstooccurcontinuallywhilethefacilityisinoperation:a.Ensureallrequestsforre-entryactivitiesaredocumentedonAttachment3A,Re-entryLog.1)CompletetheTaskRequestsectionofAttachment3A(lettersA-C)withinformationprovidedbytheTSCCoordinatorwithOSC.b.GivetheRe-entryLogtotheOSCSupervisorforcompletionoftheTeamAssignmentsection.UponreturnoftheRe-entryLogformfromtheOSCSupervisor:1)ProvidetheinformationintheTeamAssignmentsectionofAttachment3A,Re-entryLog(lettersD-G)totheTSC.2)InstructtheOSCAdministrativeTech/LogkeepertoupdatetheOSCStatusBoardwithRe-entryTeaminformation.INITIAL REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:30of52ATTACHMENT3OSCCOORDINATORWITHTSCCHECKLIST(Page2of2)B.1.(continued)d.InformtheOSCSupervisorwhentheEC/TSCwillbeconductingafacilitybriefing.e.Monitorinformationonthestatusboardforaccuracy.f.ProvidetemporarycoveragefortheOSCSupervisorduringRe-entryTeambriefingsanddebriefings,asrequested.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.1.PhoneconnectiontoTSCterminated.2.AllRe-entryLogentriescompletedandclosedout.3.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheOSCSupervisor.4.Returnedpositionnotebooktostorageshelf.
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:31of52ATTACHMENT3ARE-ENTRYLOG(Page1of1)TASKREQUEST(TSC)TheTSCfillsinthissectionandcommunicatestheinformationtotheOSC.0InvestigateA.Description0Repair0OtherB.*Priority:01(target10mins)02(target20mins)03(target30mins)C.TSCContact:TEAMASSIGNMENT(OSC)TheOSCfillsinthissectionandcommunicatestheinformationtotheTSC.D.TeamNo:F.TimeOut:E.Re-entrySupv.:G.TimeIn:TASKREQUEST(TSC)TheTSCfillsinthissectionandcommunicatestheinformationtotheOSC.0InvestigateA.Description0Repair0OtherB.*Priority:01(target10mins)02(target20mins)03(target30mins)C.TSCContact:Phone:TEAMASSIGNMENT(OSC)TheOSCfillsinthissectionandcommunicatestheinformationtotheTSC.D.TeamNo:F.TimeOut:E.Re-entrySupv.:G.TimeIn:AssignmentofPriorities/Re-EntryTeamDispatchTargets(AssignmentofprioritiesismadebytheTSC.Thedispatchtimesaretargetsthatshouldbevigorouslypursued.)Priority1-Dispatchwithin10minutes(e.g.,fire,injury,specificOperatoractionssuchasApp.X,etc)Priority2-Dispatchwithin20minutes(e.g.,EmergencyCoordinatortoppriority,actionsrequiredtoprotectthehealthandsafetyofthepublic,etc.)Priority3-Dispatchwithin30minutes(e.g.,routinere-entry)PSL-F086 REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:32of52ATTACHMENT4OSCADMINISTRATIVETECH/LOGKEEPERCHECKLIST(Page1of2)NOTE~Twopersonsserveinthisposition.AdivisionoflaborshouldbeestablishedthatbestsupportstheOSCSupervisor.~Whennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONRefertosection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.EnsurestatusboardsintheOSCarecleanpriortofacilityactivation.3.Ensurethetelevisionsetsinrooms2200and2300areturnedonandsetonchannel9(forthe"Videolink").INITIALB.FACILITYOPERATION1.EnsurethatallpersonnelinbothRooms2200and2300aresignedinonthestatusboardandthatthisinformationconcurswithAttachment2A,OSCEROShiftStaffingandAccountabilityRoster.Stepstooccurcontinuallywhilethefacilityisinoperation:a.MaintaintheOSCSupervisorLogbookonceturnedoverfromOSCSupervisor(useAttachment4A,LogKeepingandStatusBoards).b.MaintaintheOSCStatusBoard(useAttachment4A,LogKeepingandStatusBoards).ReviewstatusboardentrieswiththeOSCCoordinatorwithTSCtoensureaccuracy.ProvideadministrativeassistanceandsuppliestotheOSCSupervisorandRe-entrySupervisors(suppliesareavailableintheHPEmergencyKit).
REVISIONNo.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:33of52ATTACHMENT4OSCADMINISTRATIVETECH/LOGKEEPERCHECKLIST(Page2of2)C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.1.Thestatusboardhasbeenclearedandreturnedtopreactivationcondition.2.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheOSCSupervisor.3.Returnedpositionnotebooktostorageshelf.
REVISIONNO.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:34of52ATTACHMENT4ALOGKEEPINGANDSTATUSBOARDS(Page1of1)LOGKEEPING1.Exampleofinformationtobedocumenteda.Keyevents(e.g.,classificationchanges,injuries,etc.)b.Statuschangesinequipment,radiologicalconditions,personnel,etc.c.Decisionsoractionstakend.Statusboardentriese.Otheritemsofsignificance2.Logentryrequirementsa.Timeofentryb.Useinkc.Writelegiblyd.Useconciseandaccuratewordinge.Strikethroughandinitialanychangesf.DonotremovepagesfromthelogSTATUSBOARDS1.Informationshouldbeupdatedevery15-30minutesandnotlongerthan60minutes.2.Reviewpostedinformationforaccuracy(e.g.,reviewtheRe-entryTeamnumberagainsttheRe-entryLog)andverifydiscrepancieswiththeOSCCoordinatorwithTSC.3.Designatecorrectedinformationbycirclingtheentryontheboard.4.Whenallavailableblanksarefilledinforagivenparameter/item,beginagainwithadifferentcoloredmarker,erasetheexistinginformation(oneblank/lineatatime)andenterthenewinformation.
REVISIONNo.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:35of52ATTACHMENT5OSCRE-ENTRYSUPERVISORCHECKLIST(Page1of4)NOTE1.ThischecklistappliestothefollowingRe-entrySupervisorpositions(responsibilitiesoftheOSCHPRe-entrySupervisor(HPOSC)areprovidedinHP-200,HealthPhysicsEmergencyOrganization):OSCElectricalRe-entrySupervisorOSCMechanicalRe-entrySupervisorOSCOPSRe-entrySupervisorOSCl&CRe-entrySupervisorOSCChemistrySupervisor2.ThisattachmentalsoprovidesguidelinesforthefollowingRe-entryTeammembers:OSCElectricianOSCMechanicOSCNonLicensedOperatorsOSCl&CSpecialistOSCChemist3.Whennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATION1.Refertosection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.Assistinpreparationandset-upoftheOSC.INITIALNOTE~Initially,on-shiftNon-LicensedOperators(NLOs)areunderthecontroloftheNPSandareaccountedforontheOperationsAccountabilityAid.Followingsiteevacuation,NLOsreporttotheOSCandarethenconsideredpartoftheOSCstaff.~Extra(nonon-shift)NLOsreporttotheOSCandarepartoftheOSCstaff.3.EnsuredepartmentalRe-entryTeammembersaresigned-inonaformsimilartoAttachment2A,OSCEROShiftStaffingandAccountabilityRoster.4.ProvideactivationstatusofyourgrouptotheOSCSupervisor.
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:36of52ATTACHMENT5OSCRE-ENTRYSUPERVISORCHECKLIST(Page2of4)FACILITYOPERATION1.AllRe-entrySupervisorsinitiateaLogbook.INITIALStepstooccurcontinuallybyallRe-entrySupervisorswhilethefacilityisinoperation:a.MaintaindocumentationofactivitiesintheLogbook.b.Re-entryChecklist-WhendirectedbytheOSCSupervisorcompletethefollowinginresponsetoarequestforaRe-entryTeam:1)CompletePartI,TeamAssignment,portionofAttachment5A,Re-entryTeamForm,asrequestedbytheOSCSupervisorbyselectingRe-entryTeammembersandaRe-entryTeamLeader.ProvidenamesandTLDnumberstotheHPOSCSupervisor.2)WorkwithothermembersoftheOSCstafftocompletePartII,Task,oftheRe-entryTeamForm.3)ReviewAttachment5B,Re-entryTeamGuidelines,asnecessary.4)CompletePartIII,TeamBriefing,ofAttachment5A,Re-entryTeamForm.5)6)ProvidetheRe-entryTeamFormtotheOSCSupervisorforbriefingverification.Oncedispatched,communicatewiththeRe-entryTeamandkeeptheOSCSupervisorinformedofstatus/activities.7)UponreturntotheOSC,directtheRe-entryTeamtocompletePartIV,FieldNotes,ofAttachment5A,Re-entryTeamForm,asappropriate.8)RetaincompletedcopiesofAttachment5A,Re-entryTeamForm.
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:37of52B.ATTACHMENT5OSCRE-ENTRYSUPERVISORCHECKLIST(Page3of4)2.(continued)c.CoordinateshiftreliefactivitieswiththeOSCSupervisor.d.PerformshiftturnoverwithanalternateRe-entrySupervisor,whendirected.1)Ensureshiftturnoverofotherdepartmentalre-entrypersonnel.INITIAL3.$4OPSRe-EntrySupervisorEstablishlinkwithOPSConferenceBridge(originatedintheTSC).NOTEAtsiteevacuationandatthedirectionoftheEC,NLOswillreporttotheOSC.Verifythaton-shiftNLOsareawareofthefollowing(maybecommunicatedthroughtheControlRoomordirectly):1)Emergencydosimetry(ElectronicPersonalDosimeter(EPD)),intheControlRoomHPEmergencyKits,mustbeusedatALERTorhigheremergencyclass.2)TheECwilldirecttheNLOstotheOSCfollowingasiteevacuation.3)TravelroutetotheOSCwillbeestablishedbytheHPOSC.
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:38of52ATTACHMENT5OSCRE-ENTRYSUPERVISORCHECKLIST(Page4of4)B.3.(continued)INITIALCAUTIONAsspecifiedinADM-17.09,Invoking10CFR50.54(x),theEmergencyCoordinator(EC)may(withtheconcurrenceofalicensedsenioroperator)waivere-entryrequirementstoplacetheplantinasafeshutdownconditionormitigatearelease,ifthisimmediateactionisneededtoprotectthepublichealthandsafet.CoordinateoperatoractionsovertheOPSConferenceBridgeandinconjunctionwiththeOSCSupervisor.C.FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.,1.Directeddepartmentalpersonneltoturnindocumentation.2.,ClosedouttheLogbook.3.GenerateNuclearPlantWorkOrders(NPWOs),followingterminationoftheemergency,toensureallmaintenanceactivitiesarerecordedinplantmaintenanceprogramrecords,asnecessary.4.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheOSCSupervisor.5.Returnedpositionnotebooktostorageshelf.
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:39of52TeamAssignmentPartI.A.TeamNo.:C.TeamMembers:ATTACHMENT5ARE-ENTRYTEAMFORM(Page1of1)B.TeamLeader:NameTLDNameTLDPartII.TaskA.TaskDescription:()Investigate()Repair()OtherB.Assessment:(TheRe-EntrySupervisorshouldensureallapplicableareasareconsidered.)()Clearance(OPS)()Security()Safety/HeatStress()Radiological()Tools()Materials/Parts()Procedures/Drawings()SpecialConsiderationsC.Communications:,Re-entrySupervisororOSCSupervisorVerifiedby:PartIV.FieldNotesTheRe-Entryteammayusethissectionforanynotesaboutconditionsfound,workcompleted,etc.,OSCSupervisorRe-EntrySupervisorName:Primary:()RadiochannelAlternate:()Phoneext(s)PartIII.TeamBriefingBriefingCheck-off:(TheRe-EntrySupervisorshouldensureallapplicableareashavebeenreviewedduringthebriefing.)()descriptionoftask()teamhasnecessarytools,etc()HPbriefing-radiologicalconditions/dress-out,etc()communications()SpecialconsiderationsCompletedby:PartV.De-BriefA.TimereturnedtoOSC:B.Conditionsfound/TaskCompleted?:C.TaskDe-briefcompletedby:D.TeamreporttoHP/Dosimetry:PSL-F089EffectiveDate:06/15/01 REVISIONNO.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:40of52ATTACHMENT5BRE-ENTRYTEAMGUIDELINES(Page1of1)MEMBERSOFRE-ENTRYTEAMS:1.Shouldobtain,asappropriate,tools,equipment,supplies,andcommunicationsequipmentnecessarytoperformemergencyrepair/damagecontrolactivities.2.ShouldreportanyequipmentorsupplyproblemstotheRe-entrySupervisor.3.Shalldonpersonalprotectiveequipment/clothinganddosimetry,ifdirectedbytheHPOSC.4.Shouldproceedalongthepre-plannedroutetotheworklocationandperformemergencyrepair/damagecontrolactivities,asdirectedbytheRe-entrySupervisor,HPOSC,andOSCSupervisor.5.ShouldmaintaincommunicationswiththeRe-entrySupervisor.6.Shouldrequestadditionalpersonnel/equipment,asnecessary,throughtheRe-entrySupervisor.7.Shallcheckdosimetry/monitorexposure.IfthealarmoftheElectronicPersonalDosimeter(EPD)sounds,followtheinstructionsprovidedbytheHPOSC.8.Shouldfollowtheself-monitoringandpersonneldecontaminationproceduresasspecifiedbytheHPOSC,whenthere-entryiscomplete.9.ShouldcompletePartIV,FieldNotes,inAttachment5A,Re-EntryTeamForm,andreporttotheOSCSupervisorfordebriefonreturntotheOSC.10.ShouldreporttoHPforexposurehistoryupdate.11.Shouldstand-byforfurtherinstructionsfromtheRe-entrySupervisor.
REVISIONNo.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:41of52ATTACHMENT6OSCRE-ENTRYFOREMANCHECKLIST(Page1of2)NOTE1.ThischecklistappliestothefollowingRe-entryForemanpositions:OSCElectricalChiefOSCMechanicalForemanOSCl&CShopSupervisor2.Whennecessaryorappropriate,stepsofthischecklistmaybeerformedoutofseuence.A.FACILITYACTIVATION1.Refertosection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.AssisttheRe-EntryTeamSupervisorinidentificationofdepartmentaljourneyman.INITIALB.FACILITYOPERATIONStepstooccurcontinuallywhilethefacilityisinoperation:AssisttheRe-entrySupervisorinre-entryactivitiesasfollows:1)Evaluationofre-entrytasks.2)Selectionofdepartmentalpersonnelforre-entrytasks.
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:42of52ATTACHMENT6OSCRE-ENTRYFOREMANCHECKLIST(Page2of2)B.1.a.(continued)INITIALNOTE~AcomputerprovidesaLANconnectionandaccesstotheTotalEquipmentDatabase(TEDB)inPassport.~Procedures,TechManuals,anddrawingsareavailableacrossthehallfromtheOSCintheMaintenanceLibrary(anInformationServicesrepresentativeispartoftheOSCstaff,ifneeded).3)DeterminationoflevelofinstructionneededbytheRe-entryTeammembers.4)Selectionoftools,equipment,andsuppliesnecessarytoperformemergencyrepair/damagecontrolactivities.b.PerformasaRe-entryTeamLeader,asdirected.C.FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.1.Directeddepartmentalpersonneltoevaluatestatusofequipmentandsuppliesandreportdeficiencies.2.HaddepartmentalRe-entryTeammembersreturnallequipmentandsuppliestonormal/storagelocations.3.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheOSCSupervisor.4.Returnedpositionnotebooktostorageshelf.
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:43of52ATTACHMENT7OSCDEPARTMENTALREPSCHECKLIST(Page1of3)NOTE1.ThischecklistappliestothefollowingOSCDepartmentReps:OSCSafetyRepOSCNMMStaffRepOSCInformationServicesRepOSCProtectionandControlRep2.Whennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.FACILITYACTIVATION1.Refertosection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.OSCInformationServicesRepVerifyproceduresbypostingrevisionnumbersonthestatusboard.Postallprocedures(EPIP,HP,Chem).ConsultthecontrolcopyofproceduresintheOSCHPEmergencyKitorfollowthestepsbelowtoprintoutanEPIPlist.1)InLotusNotes,clickonthePSLProceduresicon.2)OntheSearchlinetoolbar,clickthefarrightbutton(with2circlesandadownarrow).3)SelectGroupSearchfromthedropdownmenu.4)IntheSearchlinetype"EP"(wherethe"XX"is).5)ClickSearchorhitEnter.6)EPIPlistisnowdisplayed(notinanyparticularorder)~INITIAL REVISIONNO.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT7OSCDEPARTMENTALREPSCHECKLIST(Page2of3)PAGE:44of52A.2.a.(continued)7)Toprintthelist:-ClicktheFile.-SelectPrintfromthedropdownmenu.-SelectViewOptionsinthedialoguebox.-ClickOK.INITIALb.EnsurecopiesoftheEmergencyResponseDirectory(ERD)areavailableforusebytheOSCSupervisorandOSCRe-entrySupervisors.CopiesoftheERDmaybeobtainedfromtheHPEmergencyKit.3.OSCSafetyRep(orasdesignatedbytheOSCSupervisor)a.InitiatesetupofRoom2200inaccordancewithAttachment7A,Room2200Guidelines,and7B,Room2200SetUp.FACILITYOPERATIONNOTEComutersareavailableinRoom2300foraccessintheLAN,asneeded.Stepstooccurcontinuallywhilethefacilityisinoperation:a.OSCSafetyRep(orasdesignatedbytheOSCSupervisor)1)SuperviseactivitiesinRoom2200.FollowtheguidanceprovidedinAttachment7A,Room2200Guidelines.
REVISIONNO.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:45of52B.1.ATTACHMENT7OSCDEPARTMENTALREPSCHECKLIST(Page3of3)(continued)b.EachrepresentativeshouldbealerttoassisttheOSCSupervisorinadvisingRe-entryTeamsorparticipatinginre-entryasneeded.c.Providesupportand/orexpertiseasfollows:1)OSCNMMStaffRep-materialsandequipmentinStores2)OSCProtectionandControlRep-off-sitepowerandswitchyardissues3)OSCInformationServicesRep-obtainand/orproducecopiesoftechmanuals,drawings,procedures,diagramsandothercontrolleddocuments,asrequested.INITIALFACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheOSCSupervisor.2.Returnedpositionnotebooktostorageshelf.
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:46of52A.SETUPATTACHMENT7AROOM2200GUIDELINES(Page1of3)InstructpersonneltoarrangethetablesandchairsinaccordancewiththefacilitylayoutshowninAttachment7B,Room2200SetUp.Eachdepartmentshouldensuretheirareaisproperlylocatedandarranged.2.TheOSCSupervisorshouldbeadvisedwhentheroomissetup.B.STAFFANDACCOUNTABILITYAssistSecurityinestablishingaccountabilitybyinstructingallpersonneltosigninonAttachment2A,OSCEROShiftStaffingandAccountabilityRoster.Instructallforementoensuretheirpersonnelaresignedin.2.EnsureonecompletedcopyofAttachment2AisprovidedtotheOSCSupervisorandanothercompletedcopyisgiventooneoftheOSCAdministrativeTech/Logkeepers.CONDUCTOFFACILITYOPERATIONS1.IdentifyandprocesspersonnelfromHP,OPS,ChemistryandMaintenancetoinitiallyestablisharapidresponse/contingencyRe-entryTeam.Reviewtherules:a.Orderlyconductistobemaintainedatalltimes.b.PersonnelaretolistentoTSCbriefingsbroadcastovertheVideolink.c.BriefingswilloccurfollowingtheTSCbriefings(approximatelyevery30minutes)andwillallowforquestions.PersonnelareallowedtoleaveRoom2200(tousethebathroom,makecopies,gotheMaintenanceLibrary,etc.),butmustnotifytheirforemanifappropriate,andinallinstances,signoutonrosterprovidedbySecurity.e.PersonnelareNOTtoenterRoom2300unlessinstructedtodoso.
REVISIONNO.:PROCEDURENo.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:47of52C.(continued)ATTACHMENT7AROOM2200GUIDELINES(Page2of3)3.Havepersonnelidentifyanytools,instrumentsorothersuppliesthatarenecessaryfortheirresponseefforts.TheserequestsneedtobeprovidedtotheOSCSupervisorsothatarrangementscanbemadetoobtainthismaterial.D.HPBRIEFINGSInadditiontore-entryspecificbriefings,HPshouldroutinelyprovidegeneralHPbriefingstopersonneladdressingthefollowing:a.LocationoftheAccessControlPoint.b.Currentdressoutrequirements.c.Dosimetry,alarmsetpoints,andappropriateactionsifanalarmshouldsound.d.Generalradiologicalconditionsbasedonon-sitesurveydata.e.RadiologicalconditionsintheOSC.f.Releaseordoseconcerns.SAFETYBRIEFINGS1.Safetyconsiderationsassociatedwithre-entriesshouldinclude:a.Clearanceconsiderations.b.Cautioninunknownenvironments,forexample,bewaryofsteamleaksorotherpotentiallydangerousconditions.c.Personalsafetywithrespecttoyourphysicalcondition,forexample,remainsensitivetothedangersofHeatStress.d.Befamiliarwithsurroundingsandalerttochangingconditions.
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT7AROOM2200GUIDELINES(Page3of3)PAGE:48of52E.1.(continued)e.KeepincontactwiththeRe-entrySupervisor.f.Performtheworkassafelyaspossible.Wheninthefield,alwaysreviewanyproposedchangeinthere-entryplan(ingress,egress,orassignedtask)withtheRe-entrySupervisor.
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:49of52ATTACHMENT7BROOM2200SETUP(Page1of1)CJ[IWl9CI.:3HEALTHPHYSICSEMERGENCYKITSECIJflflYRM2200QQQQQQQQQQOPEAATIONS~PIKTT.aCCN~TROI.0EIXCXMAINT.SAFElY0MECH.MAINT.00HEAIJHIACMuser~PHYSCSPy~nl<FW4PP0C")o~OOOOO<N REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTPAGE:50of52ATTACHMENT8OSCSECURITYCHECKLIST(Page1of3)NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofseuence.A.FACILITYACTIVATION1.Refertosection5ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.INITIALNOTEPriorityisgiventoidentifyingtheminimumstaff(positionsinboldonAttachment2A)whichallowstheOSCSupervisortodeclaretheOSCoperational.AccountabilitymustbeestablishedforbothRoom2200and2300.Thefacilityheadcountmustagreewiththenumberofpersonssinedinontheaccountabilitforms.2.UsingAttachment2A,OSCEROShiftStaffingandAccountabilityRoster,initiatetheestablishmentofinitialfacilityaccountability.B.FACILITYOPERATIONNOTEPriorityisgiventoidentifyingtheminimumstaff(positionsinboldonAttachment2A)whichallowstheOSCSupervisortodeclaretheOSCoperational.AccountabilitymustbeestablishedforbothRoom2200and2300.Thefacilityheadcountmustagreewiththenumberofpersonssinedinontheaccountabilitforms.Logthenamesandbadgenumbersofpersonsfillingthefollowingpositionsandmaintainaccountabilityforthemevenafterleavingthefacilityand/orsite:a.AssemblyAreaSupervisor:b.ControlRoomHPcoverage1)Unit1:2)Unit2:
REVISIONNO.:PROCEDURENO.:EPIP-05PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT8OSCSECURITYCHECKLIST(Page2of3)PAGE:51of52B.1.(continued)c.FieldMonitoringTeam-Red1)Driver:2)HP:d.FieldMonitoringTeam-Blue1)Driver:2)HP:e.FieldMonitoringTeam-Orange1)Driver:2)HP:Other(e.g.,HPsenttooff-siteAssemblyArea,hospital,etc.):2.Establishinitialfacilitypersonnelaccountablerosterrequired30minutefollowingevacuationofnon-essentialpersonnel.3.ReviseaccountabilitywhenNonLicensedOperatorsreporttotheOSCfollowingsiteevacuation.4.CoordinatewiththeAssemblyAreaSupervisortoestablishSecurityattheoff-siteAssemblyAreabasedonSecurityresourcesavailability.INITIAL REVISIONNO.:PROCEDURENO.:EPIP-05B.(continued)PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEOPERATIONALSUPPORTCENTERST.LUCIEPLANTATTACHMENT8OSCSECURITYCHECKLIST(Page3of3)PAGE:52of52INITIALStepstooccurcontinuallywhilethefacilityisinoperation:a.AssisttheTSCSecuritySupervisorinmaintainingsiteaccountability.b.AssistRe-entryTeamsingainingaccesstoplantareas,asneeded.c.Assistoff-siteagenciesingainingplantaccess.d.AdvisetheOSCStaffofsecurityrelatedmatters.e.FollowSecurityProcedures.C.FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremainintheositionnotebook.1.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheOSCSupervisor.2.Returnedpositionnotebooktostorageshelf.
.e'r>~*
Title:FPLST.LUCIEPLANTEMERGENCYPLANIMPLEMENTINGPROCEDURESAFETYRELATEDProcedureNo.EPIP-06CurrentRev.No.4EffectiveDate:06/15/01ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFAGGOTResponsibleDepartment:RevisionSummaryEMERGENCYPLANNING0"0PROCEDUREPRODUCTIOi"IddRevision4-Deletedexposureguidelinebasis,revisedstateliaisontitle,aed6AMdirectreportstoEOPorgchart,clarifiedinstructions,revisedPARbriefingguidanceandmadeeditorialandadministrativechanges.(J.R.Walker,06/11/01)Revision3-THISPROCEDUREHASBEENCOMPLETELYREWRITTEN.AddednewPARbriefattachment.DeletednotificationandPARattachment(relocatedtonewEPIP-08.-MovedresponsibilityforpreparingStateNotificationFormfromEOFHRDCommunicatortoEOFRMOpsAdvisor/Logkeeper.Addalternateinstructionforprocedurerevisionverification.Madeeditorialandadministrativechanges.AddedETMActivitiesListform.(DonnaCaiabrese,05/31/00)RevisionFRGReviewDate12/15/97RevisionFRGReviewDate06/07/01ApprovedByJ.ScarolaPlantGeneralManagerApprovedByR.G.WestPlantGeneralManagerN/ADesignatedApproverN/ADesignatedApprover(MinorCorrections)ApprovalDate12/15/97ApprovalDate06/11/01SOPSDATEDOCTPROCEDUREDOCNEPIP-06SYSCOMPCOMPLETEDITM4Qi(g'900+
9)5.E REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTTABLEOFCONTENTSPAGE:2of116SECTIONPAGE1.0PURPOSE
52.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTS.~...~.~....~..~..3.0RESPONSIBILITIES93.1RecoveryManager................3.2EOFEmergencyTechnicalManager...3.3EOFNuclearLicensingManager......3.4EOFHealthPhysicsManager......~.3.5EOFEmergencySecurityManager..~.3.6EOFAdministrativeSupervisor.......3.7EOFRMOPSAdvisor/Logkeeper.....3.8NuclearDivisionDutyOfficer3.9EmergencyControlOfficer.~.~.....~3.10GovernmentalAffairsManager~......3.11RiskManager3.12EPManager3.13EOFEmergencyInformationManager~.4.0DEFINITIONS....~..~.~~....~~.~~..~~~5.0INSTRUCTIONSATTACHMENTS~~~~~91011111212131313131414141517ATTACHMENT1EOFEmergencyResponseOrganization19ATTACHMENT2RecoveryManagerChecklist......20ATTACHMENT2AEOFEROShiftStaffing.....ATTACHMENT2BEOFStaffBriefing/UpdateAgenda~....2425ATTACHMENT2CStateandCountyPARBriefingGuideline.........27ATTACHMENT2DDe-escalationGuidelines....~..29ATTACHMENT2ERecoveryPlanning30 REVISIONNo.:PROCEDURENo.:EPIP-06SECTIONPROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTTABLEOFCONTENTS(continued)PAGE:3of116PAGEATTACHMENTS(continued)ATTACHMENT3EOFRMOPSAdvisor/LogkeeperChecklist31ATTACHMENT3ATypicalInformationtobeincludedintheRMLogbook34ATTACHMENT4EOFEmergencyTechnicalManagerChecklistATTACHMENT4AETMActivitiesList..ATTACHMENT5EOFProjectEngineerChecklistATTACHMENT5AEngineeringTaskandTechnicalResponseFormATTACHMENT5BEngineeringTaskListATTACHMENT5CEngineeringShiftStaffingScheduleATTACHMENT6EOFEngineerChecklist................ATTACHMENT7EOFERDADSOperatorChecklist35~383942~43444547ATTACHMENT7AERDADSDataAcquisition...ATTACHMENT7BERDADSDataPoints~~~~~~~~~~4952ATTACHMENT8EOFStatusBoardKeeperChecklist...........ATTACHMENT9EOFNuclearLicensingManagerChecklist......ATTACHMENT9ATypicalInformationtobeincludedintheLogbook.ATTACHMENT10EOFCommunicatorChecklist...ATTACHMENT10ACommunicationsGuidelines....6062656670ATTACHMENT10BPlantDataSheet..78ATTACHMENT11CountyTechnicalAdvisorChecklist81
,
REVISIONNo.:PROCEDURENO.:EPIP-06SECTIONPROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTTABLEOFCONTENTS(continued)PAGE:4of116PAGEATTACHMENTS(continued)ATTACHMENT12EOFHealthPhysicsManagerChecklist83ATTACHMENT12AExposureLimitsforEmergencyResponsePersonnel86ATlACHMENT13EOFDoseAssessor/FMTCoordChecklist........87ATlACHMENT14EOFHPTechSupportChecklist~~~~~~~~~~89ATlACHMENT15EOFRadStatusBoardKeeperChecklistATTACHMENT16EOFAdministrativeSupervisorChecklist......ATlACHMENT17EOFAdministrativeStaffChecklist............ATlACHMENT17AEOFTelecopyLogATTACHMENT18EOFEmergencySecurityManagerChecklistATTACHMENT18AInjuredPersonReport.......~.~~~...91939699100103ATTACHMENT19NuclearDivisionDutyOfficerChecklist....~.....104ATTACHMENT19ATypicalInformationtobeincludedintheECOLogbook~..............~~...~~..~...ATTACHMENT20EmergencyControlOfficerChecklist...~....ATTACHMENT21GovernmentalAffairsManagerChecklist.....ATTACHMENT22EmergencyInformationManagerChecklist...ATlACHMENT22ANewsBriefingGuidelinesATTACHMENT23EIM/ENCTechnicalAdvisorChecklist....106107109114115 REVISIONNO.:PROCEDURENo.:EPIP-061.0PURPOSEPROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:5of1161.1DiscussionThisprocedureprovidesinstructionsfortheactivationandoperationoftheEmergencyOperationsFacility(EOF).1.2LocationandDescriptionTheEOFisadedicatedfacilitylocatedattheintersectionofStateRoute712(MidwayRoad)andI-95approximately101/2mileswestoftheSt.LuciePlant.TheEOFhasemergencycommunicationsequipment,precalculatedemergencydata,pertinentreports,plans,procedures,anddrawingsavailableforuse.1.3EOFFunctions1.AccidentassessmentinconjunctionwiththeTechnicalSupportCenter(TSC)2.Protectiveactiondecisionmaking3.Off-sitenotifications(State,County,NRC)4.Off-sitedoseassessment5.Off-sitefieldmonitoringactivities6.Coredamageassessment7.InterfacilitycommunicationswiththeTSC8.Interactionwithoff-siteofficials9.Directionofrecoveryoperations REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:6of1161.0PURPOSE(continued)1.4MinimumStaffingThefollowingisarecommendedlistoftheminimumpositionsneededforEOFoperation:RecoveryManagerEOFRMOPSAdvisor/LogkeeperEOFCommunicator(HRD)ERDADSOperatorOREOFCommunicator(toTSC)EOFDoseAssessor/FMTCoordg,1.5ActivationActivationoftheEOFistheresponsibilityoftheRecoveryManager(RM)andisrequiredforaSiteAreaEmergencyorGeneralEmergency.EOFpersonnelshouldbeplacedinthefacilityforanAlert,asconditionswarrant.ArrangementshavebeenmadetoactivatetheEOFinatimelymanner.1.6OperationsTheEOFhassufficientspacetoaccommodatetheFloridaPower8LightCompany(FPL)responseorganizationanddesignatedrepresentativesoftheFederal,State,andLocalauthorities.Thisco-locationallowsforaneffectivecommunicationsinterface,coordinateddecisionmaking,andtimelyimplementationofprotectiveactions.
REVISIONNo.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:7of11
62.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTSNOTEOneormoreofthefollowingsymbolsmaybeusedinthisprocedure:gIndicatesaRegulatorycommitmentmadebyTechnicalSpecifications,ConditionofLicense,Audit,LER,Bulletin,etc.,andshallNOTberevisedwithoutFacilityReviewGroupreviewandPlantGeneralManagerapproval~Indicatesamanagementdirective,vendorrecommendation,plantpracticeorothernon-regulatorycommitmentthatshouldNOTberevisedwithoutconsultationwiththeplantstaff.
2.1REFERENCES
1~St.LuciePlantTechnicalSpecificationsUnit1andUnit2(Section6.10.1)2.St.LuciePlantUpdatedFinalSafetyAnalysisReport(UFSAR)Unit1andUnit23.St.LuciePlantRadiologicalEmergencyPlan(E-Plan)4.St.LuciePlantPhysicalSecurityPlan5.St.LuciePlantSafeguardsContingencyPlan6.St.LuciePlantTopicalQualityAssuranceReport7.E-PlanImplementingProcedures(EPIP00-13)8.St.LuciePlantEmergencyResponseDirectory(ERD)9.FloridaPower8LightCompanySt.LuciePlantRecoveryPlan10.FloridaPower&LightCompanyCorporateCommunicationsNuclearEmergencyPlan.11.QI-17-PSL-1,QualityAssuranceRecords REVISIONNo.:4PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:8of11
62.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTS(continued)
2.1REFERENCES
(continued)12.FitnessforDutyRule,10CFR2613.ReactorOperatorTechManual8770-1205814.NUREG-0654,Rev.1,FEMARep.1,CriteriaforPreparationandEvaluationofRadiologicalEmergencyResponsePlansandPreparednessinSupportofNuclearPowerPlants;November,1980.15.St.LucieUnit1and2as-builtdrawings,NuclearEngineeringfiles,andEbascoEngineeringfiles16.InstituteofNuclearPowerOperations,EmergencyResourcesManual-INPO86-032.17.NuclearEnergyPolicyonExposureLimitsforEmergencyResponsePersonnel,RevisiontoPolicyStatement,Ltr.No.JNO-HP-94-056,26October,1994.2.2RECORDSREQUIRED1.Thefollowingshallberetainedfollowingaplantemergency:~Checklists,dataandpaperworkgeneratedperthisprocedure.~Logbooksmaintainedduringtheplantemergency.2.RecordedinformationshallbeforwardedtoEmergencyPlanningfollowingtheevent,forreviewandarchivalinaccordancewithTechnicalSpecification6.10.1andQI-17-PSL-1.2.3COMMITMENTDOCUMENTS1~ConditionReport96-2900,(ReviewandapprovalofRecoveryPlan)2.PMAI99-0-024(RMBriefingConsistency)
REVISIONNo.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:9of1163.0RESPONSIBILITIES3.1RecoveryManager(RM)DeclarestheEOFoperationalforanySiteAreaEmergencyorGeneralEmergency.2.EstablishesandmaintainscommandandcontroloftheEOF.3.AssumesthefollowingresponsibilitiesfromtheEmergencyCoordinator(EC)whentheEOFispreparedtogooperational:A.Notificationofoff-siteagencies(StateandCounties),andB.DevelopsandissuesProtectiveActionRecommendations(PARs)toStateandCountyofficials.4.DeclarestheEOFoperationalwiththeconcurrencefromtheEC.5.EnsuresnotificationofStateandCountyagenciesoccurswithinfifteen(15)minutesfollowinganychangeinemergencyclassificationandnotificationoftheNRCoccursimmediatelyfollowingnotificationoftheStateandCounties,andinallcaseswithinone(1)hour.6.Establishespolicies,forsituationsinwhichnocompanypolicycurrentlyexists,tosupporttheactionsthatwillaidinmitigationoftheemergency.7.Expendsfundsasnecessarytocopewithemergencysituations.8.ProvidessupporttotheECasnecessary.9.ProvidesconcurrencetotheECforexceeding10CFR20limitsforemergencyresponsepersonnel,asappropriate.
REVISIONNo.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:10of1163.0RESPONSIBILITIES(continued)3.1RecoveryManager(RM)(continued)10.Requestsadditionalsupportasnecessary.11~InterfaceswiththeNuclearRegulatoryCommission,DirectorofSiteOperations(NRC,DSO)whentheNRCSiteTeamarrivesattheEOF.12.De-escalatesalleventsclassifiedasSiteAreaEmergencyorGeneralEmergency.13.PreparesanIncidentReportforsubmittaltotheStateDivisionofEmergencyManagement(DEM)andtheNRCwithintwenty-four(24)hoursafterterminationofanAlertorhigheremergencyevent.3.2EOFEmergencyTechnicalManager(ETM)1.ProvidesengineeringsupporttotheEOFbydirectingallengineeringresponseincluding:A.NuclearEngineeringB.NuclearFuelsEngineeringandcoredamageanalysisC.ElectricalEngineeringD.I8CEngineeringE.MechanicalEngineeringF.CivilEngineering2.SupportstheTSCinproblemsolvingbasedonengineeringdesignandas-builtconstructiondetails.3.Overseesplantdataacquisitionandposting.4.InterfaceswiththeNRCReactorSafetyCoordinatorwhentheNRCSiteTeamarrivesattheEOF.
REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:11of116EPIP-06ST.LUCIEPLANT3.0RESPONSIBILITIES(continued)3.3EOFLicensingManager1~OverseesEOFcommunicationsperformedbythefollowingcommunicators:A.HotRingDown(HRD)CommunicatorB.EmergencyNotificationSystem(ENS)CommunicatorC.HealthPhysicsNetwork(HPN)CommunicatorD.TSCCommunicator2.EnsuresthattheInstituteofNuclearPowerOperations(INPO)iskeptabreastofemergencystatusandresourcerequirements.3.ServesasprimaryliaisonwiththeNRConcetheSiteTeamarrivesattheEOF,interfacingwiththeEmergencyResponseCoordinator.3.4EOFHealthPhysicsManager(HPM)1.Directsthecollection,assessment,andinterpretationofallradiologicalandradiochemistryinformationintheEOF.2.AssiststheRMinPARdecisionmaking.3.Ensuresthatradiologicalquestions/concernsarisingfromtheEmergencyNewsCenter(ENC)areaddressed/resolved.4.InterfaceswiththeStateofFlorida'sDepartmentofHealth,BureauofRadiationControlonallradiologicalmatters.5.InterfaceswiththeProtectiveMeasuresCoordinatorwhentheNRCSiteTeamarrivesattheEOF.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:12of1163.0RESPONSIBILITIES(continued)3.5EOFEmergencySecurityManager(ESM)1.Establishesfacilitysecurityandpersonnelaccountabilitythroughouttheemergency.2.EnsurestherequirementsoftheFitnessforDutyrulearemetbypersonsreportingfordutyinEOFpositions.3.CoordinateswiththeTSCSecuritySupervisortosupportanyon-sitesecurityfunctionsandindeterminingtheneedtosuspendsafeguards.4.Providestheinterfacewithlocallawenforcementandrescueagencies.5.Tracksthestatusofallsitepersonneltransportedtooff-sitemedicalfacilities.6.InterfaceswiththeSafeguards/SecurityCoordinatorwhentheNRCSiteTeamarrivesattheEOF.3.6EOFAdministrativeSupervisor1.Overseesalladministrativeservicessuchas:CAUTIONDocuments,suchasinstructions,procedures,drawings,andsoftwarewhichprovideguidance,specifications,orrequirementsaffectingthequalityofsafety-relatedstructures,systems,andcomponents,shallbecontrolled.A.AvailabilityofcontrolleddocumentsB.ReproductionanddistributionservicesC.Supportfortelephoneandtelecopyoperations2.Makesarrangementsforlongtermfacilityoperationsincludingpersonnel,supplies,andequipment.
REVISIONNo.:4PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIGNOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:13of1163.0RESPONSIBILITIES(continued)3.7EOFRMOPSAdvisor/Logkeeper1.AssiststheRMinallassignedresponsibilitiesincludingoff-sitenotificationsandProtectiveActionRecommendations(PARs).2.FulfillstheroleofRMinthe"bullpen"whentheRMisinconference.3.MaintainstheRMLogbookwhichservesastheprimaryfacilitylog.3.8NuclearDivisionDutyOfficer(NDDO)ThispositionisnotrequiredtobeintheEOF.2.Maintains24houradayon-callavailability.3.ServesasatechnicaladvisortotheEmergencyControlOfficer(ECO).4.PerformsthedutiesoftheECOifonecannotbelocated.5.EstablishesinitialcontactwithINPO.3.9EmergencyControlOfficer(ECO)ActsasthechiefnuclearofficerintheabsenceofthePresidentoftheNuclearDivision.2.ServesastheofficialspokespersonfortheNuclearDivision.3.ApprovesallpressreleasesfortheNuclearDivision.3.10GovernmentalAffairsManager(GAM)1~ThispositionisnotrequiredtobeintheEOF.2.ProvidesliaisonfunctionbetweentheECOandpublicofficials.3.WorkswiththeStateCoordinatingOfficer(SCO)andGovernor'Advisor./R4 REVISIONNO.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:14of1163.0RESPONSIBILITIES(continued)3.11RiskManager1.ThispositionisnotrequiredtobeintheEOF.2.Providesliaisontothenuclearinsuranceindustry.3.12EPManager1.ThispositionisnotrequiredtobeintheEOF.2.ProvidesemergencypreparednessprogramexpertisetotheRMandotherEOFstaffasnecessary.3.13EOFEmergencyInformationManager(EIM)Delegatesresponsibilityforverbalandwrittencommunicationasneeded.2.DetermineswhenanemergencyisseriousenoughtoactivatetheCorporateCommunications(CC)NuclearEmergencyPlan(CCNEP),includinginitiatingnotificationsandcallingforadditionalcommunicationssupportasneeded.3.CallsfortheactivationofanEmergencyNewsCenter(ENC),afterconsultingwiththeECO.4.InvitesFederal,StateandCountypublicinformationofficerstorespondtoENCwhereinformationcanbejointlyprovidedtothenewsmedia.5.DeclarestheENCoperational,incoordinationwiththeENCManagerandECO.6.EnsuresthattechnicaladvisorsareassignedtotheCountyEmergencyOperationsCenters(EOCs)andthatcontactisestablished.
REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:15of116EPIP-064.0DEFINITIONSST.LUCIEPLANT4.1EmergencyPlanningZones:1~PlumeExposurePathway(10mileEPZ)-thatarea,approximately10milesinradiusfromthecenteroftheplant,forwhichdetailedplansaremadetoprotectpeoplefromexposuretoaplumecontainingradioactivematerials.2.IngestionExposurePathway(50mileEPZ)-thatarea,approximately50milesinradiusfromthecenteroftheplant,forwhichplansaremadetoprotectpeoplefromingestionoffood-stuffsandwatercontaminatedbyradioactivematerialsreleasedfromtheplant.4.2FacilityStatus:1.Activation-therequesttostaffandestablishanEmergencyResponse.Facility(ERF)..2.Operational-whensufficientpersonnel(i.e.,minimumstaff)areavailabletoaccomplishthemandatoryfacilityfunctionsofoff-sitenotificationsanddevelopmentofPARsANDtheRMhascompletedaturnoverwiththeECforassumptionofthesefunctions.3.FullyStaffed-thecompletecomplementofpersonnelispresentinthefacility.4.3FPLEmergencyRecallSystem(ERS)-thecall-outsystemusedasthemeansofoffhourscall-out,asdescribedinEPIP-03,EmergencyResponseOrganizationNotifications/StaffAugmentation.4.4ProtectiveActionsImplemented(PAls)-actualprotectiveactioninstructionsgiventothegeneralpublicbasedontheevaluation,byStateandCountyofficials,oftheProtectiveActionRecommendations(PARs)receivedfromFPL(i.e.,actualshelterand/orevacuationresponseactionstakenbythepublic).4.5RiskCounties-thosecountieslocatedwithinthe10mileEmergencyPlanningZoneofanuclearplant.ForSt.LuciePlant,theriskcountiesareSt.LucieandMartin.
REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:16of116EPIP-064.0DEFINITIONS(continued)4.6StateAgencies:ST.LUCIEPLANTFloridaDivisionofEmergencyManagement(DEM)-headquarteredinTallahassee,responsiblefortheStateofFloridaRadiologicalEmergencyManagementPlanforNuclearPowerPlants.2.FloridaDepartmentofHealth(DOH),BureauofRadiationControl-headquarteredinOrlando,responsibleforradiologicalmonitoringanddoseassessment.4.7"VIdeolink"-aclosedcircuitaudio/visualcommunicationslinkoriginatingintheTSCwithfeedstotheOSCandtheEOFallowingtheECbriefingstobeavailableinalltheEmergencyResponseFacilities(ERFs).
REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:17of116EPIP-065.0INSTRUCTIONSST.LUCIEPLANTNOTE~ThissectionprovidesgeneralinformationandinstructionsforallEOFresponders.~Positionspecificchecklistsareincludedasattachmentstothisprocedure.~IndividualsspecificallydesignatedasmembersoftheEOFEmergencyResponseOrganization(ERO)areidentifiedintheERD.5.1ReportwhennotifiedtotheEOFasquicklyaspossibleifavailableandabletosafelydoso.5.2Uponarrivalatthefacility,eachEOFemergencyrespondershouldperformthefollowing:1~PresentSecuritywithaformofpictureidentification.2.InformSecurityofyour"fitnessforduty"status.3.ObtainandwearapositionspecificaccessbadgeavailableintheSecurityareaasyouenterthebuilding.A.Placeyournameonthebadgewithadryerasemarkerorinanyothernon-permanentmanner.4.Sign-inontheStaffingBoardlocatedonthesouthwallofthe"bullpen"(room101).5.Obtainpositionspecificnotebookwithproceduralchecklists,formsandinstructions.6.Makeyourworkstation/locationoperational.7.Notifyyoursupervisorofyourreadinessstatus.NOTEOnlycontrolledcopiesofnuclearsafety-relatedprocedures,drawings,andotheravailableplantinformationshallbeused.Non-controlleddocumentsordrawingsshallbeverifiedwithacontrolledcopypriortouseintheEOF.5.3Communicationstotheplantshouldbemadethroughthephonetalkersand/ortheTSC.
REVISIONNo.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:18of1165.0INSTRUCTIONS(continued)5.4Duringfacility,briefings,stopwhatyouaredoing,payattentionandcontributeasrequested.5.5Uponterminationoftheevent:1.AllEOFpersonnelshouldreturntheirworkstations/locationstoanormalstateandassistinrestoringthefacilitytoareadycondition.2.Collectallsignificantinformationanddocumentation,suchascompletedEPIPsandattachments,logs,notificationformsandothernotesanddatasheets,andforwardthismaterialtoEmergencyPlanning.
REVISIONNO.:PROCEDURENO.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:19of116EPIP-06ST.LUCIEPLANTATTACHMENT1EOFEMERGENCYRESPONSEORGANIZATION(Page1of1)IOcv.Arlalrsnop.ITaahaasssaLIEmergencyControlOfficer2000RecoveryManagerrOov.AnsasAI5iscsrsLIr----IOovamorsAdvisorLr-----IIIAvlarcrIILIrAocpratoryAllaraIIIr271INudosrDnsdonI-<DuneOracerIIr-----iI205IEOFOovlIMarsManagerIr-----I204IEOPressManagerI~(thoseposaonsarenclrassrodlsboInlheEOF)EPManagergersanqulradpoaeorc)EOFEmerg.InformationMgr.273EIMIENCTachAIMsor(2)204sctcrdocaTachAchcsor2gdMaranCaTashAchcccl!EOFRMOpsAdv/Logkeepor(2)(SseNolaI)IIFII101IIIIEmergencyIIcoorcgnatorI(tocsssdhecoTsc)-EOFEmag.Tschrccrr235EOFNuc.FudsErglnosr233EOFOodrlcalEnynsor230EOFEny.ScpponSorNcaa21eEopscssrssosrdKoopor213EOFERCAOSOgocacccNolo2231Eoppre(eraEnginsol233EOPNudoarEronoor237EOFlaCEnljnoor23SEOFCvsEngineer232EOPMach.Ergcnsor(2)EOFNudaarUosnslnyMyc255Eop~rcr(4)IHnpc~ENSDomalHPNCoava24eECFHpTechlkppcrl247EopAadscasaSdsKsapsr;245ECFDoseAssosscvrrMTcoord.(3)SooNeroI231EOFAdmasScsd(3)(Prp&EPIPcrdlndrdlUAuhxfralerpositionnumbersareEstedvvhhtosldon55es.<ISOminute~goal,porNUAEG0654,TableI)INoteI~OneneededbrmInImumstatgng.Note2-EitheranEAOADSOperasslOAaTSCCommunicatortsacceptabletomeetIheminimumstslrscgreoommenda5on.Indicates~stalrscglodeclareIheIaciltyopemgonat/R4 REVISIONNo.:4PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT2RECOVERYMANAGERCHECKLIST(Page1of4)PAGE:20of116CAUTIONThemandatoryfunctionoftheEOFistoassumeresponsibilityformakingnotificationsandPARs.TheRMshouldassumethisresponsibilityassoonaspracticable,butnotbeforetheEOFstaffisfullypreparedtodoso.NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1;Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.Determineifminimumstaffisavailable(refertoAttachment2A,EOFEmergencyResponseOrganizationandShiftStaffing).3.DeterminefromtheOpsAdvisorthatEOFcommunicationsareavailable.4.NotifytheECoftheEOF'sreadinesstotakeresponsibilityforoff-sitenotifications(State,CountiesandNRC)andPARs.5.BasedonconcurrencefromtheEC,declareEOFoperational(steps3&4mustbecompleted).Operationalat6.NotifythefollowingthattheEOFisoperational:a.ECb.EOFstaffc.Stateandlocalauthoritiesd.NRCe.ECO REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:21of116ATTACHMENT2RECOVERYMANAGERCHECKLIST(Page2of4)A.FACILITYACTIVATION(continued)7.RequestthatallfacilityclocksbesynchronizedwithERDADS.IncaseofERDADSfailure,synchronizewiththeaffectedControlRoom.INITIAL8.EOFfullystaffed.B.FACILITYOPERATION1.Establishbriefingfrequencyforfacilityupdates.2.DirectanRMOPSAdvisor/LogkeepertokeepLogbook.3.Stepstooccurcontinuallywhilethefacilityisinoperation:a.Off-sitenotificationsforbothState/CountyandtheNRCareapprovedandprovidedinatimelymannerandinaccordancewithEPIP-08,Off-siteNotificationsandProtectiveActionRecommendations.b.Develop/adjustandapprovePARs,asnecessaryinaccordancewithEPIP-08andwiththeassistanceoftheEOFRMOPSAdvisor/LogkeeperandtheEOFHPManager.c.ProvidePARBriefingstoStateandCountypersonnelintheEOFwiththeassistanceoftheEOFRMOPSAdvisor/LogkeeperandEOFHPManagerandusingAttachment2C,StateandCountyPARBriefingGuideline.CAUTIONTheRMshallnotdelegatethefollowing:~StateNotificationFormapproval~RecommendationofProtectiveActions~ExpenditureofFunds~PolicySettingd.RequestanRMOPSAdvisor/Logkeeperactastemporaryreliefwhenleavingthe"BullPen"~
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT2RECOVERYMANAGERCHECKLIST(Page3of4)PAGE:22of116B.FACILITYOPERATION(continued)3.(continued)e.EnsurethatProtectiveActionsImplemented(PAls)arepostedintheEOFandreportedtotheEC.f.Maintainfacilitycommandandcontrol~g.Conductfacilitybriefings(useAttachment2Btothisattachment).h.ContacttheECfrequentlytomaintainawarenessofplantconditionsandactions.(The"Videolinkmaybeusedforthispurpose.)i.-=Provide-support/resources-totheECfromotherFPLsources,nuclearpowerplantsand/orvendors.j.ReviewemergencydoseextensionswiththeEC(useAttachment12A,ExposureLimitsforEmergencyResponsePersonnel./R4k.Requestadditionalsupportasnecessary.I.RoutinelyreviewstatuswiththeECO.m.Establishpolicieswhensituationsarisewherenocompanypolicyisinplacetosupporttheactionsthatwillaidinmitigationoftheemergency.n.Expendfundsasnecessarytocopewithemergencysituations.(SolicitauthorizationfromthePresidentNuclearDivision)o.InterfacewiththeNRCDirectorofSiteOperations(DSO)andothermembersoftheSiteTeam,asrequired.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT2RECOVERYMANAGERCHECKLIST(Page4of4)PAGE:23of116B.FACILITYOPERATION(continued)4.DirecttheEOFAdministrativeSupervisortoestablishthecapabilityfor24houroperationoftheEOF.g,5.De-escalatetheemergencyclassificationtoSiteAreaEmergencyorlowerclass(useAttachment2D,De-escalationGuidelines).6.Initiatetherecoveryplans(useAttachment2E,RecoveryPlanning).C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.DirectLicensingtopreparetheIncidentReportforsubmittaltoDEMandNRC(within24hoursafterterminationofanAlertorhigheremergencyevent).2.Allfacilityactivitiesclosedout.3.Allpaperworkcollected.4.Allequipmentandsuppliesreturnedtopre-activationconditionand/orlocation.5.Providedallcompletedpaperwork(notboundinthepositionnotebook)toEmergencyPlanning.6.ReturnedpositionnotebooktoRMoffice./R4/R4 REVISIONNO.:4PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT2AEOFEROSHIFTSTAFFING*PAGE:24of116Shift***:(Page1of1)Hours:To:'RecoveryManager'OpsAdvisorHPManagerEmergencyTochnicalManagerOpsAdvisorHPTechSupportProjectEngNuclearUcensingManager'DoseAssessor/FMTCoordNuclearEng'EOFCommunicator(HRD)EOFCommunicator(ENS)EOFCommunicator(HPN)DoseAssessor/FMTCoordDoseAssessor/FMTCoordRadStatusBrdKprl&CEngCivilEngMechanicalEng'EOFCommunicator(TSC)AdminSupervisorAdminStaffMechanicalEngNucFuelsEngAdminStaffElectricalEng"EPManagerAdminStaffEmergencyControlOfficer-NuclearDivisionDutyOfficer"RiskManagerEmorgencyInfo.ManagerEIM/ENCTechAdvEIM/ENCTechAdvPlantStatusBrdKpr'ERDADSOper-Gov.AffairsManagerSt.LucioCountyTechMartinCountyTechAdvCorpComm/ENCStaffEmergencySecurityManagerRecommendedminimumstaffinginboldAcceptablealternatesforrecommendedminimumstaffing:RecoveryManagor-DesignatedalternatesInERD.RMOPS.Advisor-Anyrespondorwithactiveorpastoperatingliconsoorequivalent(RO,SRO,SROCert)atPSLorPTN.HRDCommunicator-AnyresponderERDADSOperator-AnyresponderwithworkingfamiliaritywithERDADscomputerTSCCommunicator-AnyrosponderwithplanttechnicalbackgroundDoseAssessmentCoordinator-Anyrespondertrainedfnradiologicalassessmont.*'ptionalstaffing(nottypicallyEOFresponders)'*'ongtermstaffing,refertotheSt.LuciePlantEmergencyResponseDirectory(ERD)forpositionaltomates.
REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:25of116EPIP-06ST.LUCIEPLANTATTACHMENT2BEOFSTAFFBRIEFING/UPDATEAGENDA(Page1of2)TIME:NOTE1.Updatesshouldoccurapproximatelyevery30minutes.Significantchangesineventsshouldbeannouncedpromptly.2.Briefingsshouldnotexceed10minutes.3.ReferenceinRMLogandretainforarchival.EmergencyClassification:Unit1Status:Unit2Status:CurrentInformation:NOTETakethetimenecessarytoexplaineventsattheplant.1.Classificationchanges2.Radiologicalreleaseoccurrenceortermination(thisincludessignificantchangesinsourcetermormeteorologicaldata)3.Lossorrestorationofsignificantequipmentand/orsystem,suchaslossofmake-upcapability,containmentfailure,etc.4.ChangestoPARsortoProtectiveActionsImplemented(PAls)5.Injured/ContaminatedPersonnel6.Currentmission(s)ofEOF,assigntask(s),asnecessary.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT2BEOFSTAFFBRIEFING/UPDATEAGENDA(Page2of2)PAGE:26of116OtherInformation(Requestinput/updateinformationfromotherrepresentatives.Remindcontributorstobebriefandlimitcommentstosignificantnewinformation.)HealthPhysicsRepresentative:2.EngineeringRepresentative:3.SecurityRepresentative:4.StateRepresentative:A.DEM:B.DOH:5.St.LucieCountyRepresentative:6.MartinCountyRepresentative:7.NRCRepresentative:
REVISIONNO.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT2CSTATEANDCOUNTYPARBRIEFINGGUIDELINE(Page1of2)PAGE:27of116OncetheEOFisdeclaredoperational,theRecoveryManagerhasprimaryresponsibilityfordevelopmentofProtectiveActionRecommendations(PARs)~PARsareincludedintheStateNotificationForm.NotificationofStateandCountyofficialsisaccomplishedthroughtheconductofPARBriefings.SecificGuidance1.StateandCountyPARBriefingsshallbeconductedonlyifthefollowingistrue:A.TheEOFhasbeendeclaredoperational~B.Thefollowingagenciesarerepresentedinthebriefing:(1)FloridaDEM(2)FloridaBRC(3)St.LucieCountyDPS(4)-MartinCountyDES2.TheRMshallapprovetheFloridaNuclearPlantEmergencyNotificationFormandtheSupplementalDataSheet.3.TheRMshallreviewtheinformationfromtheabovenotificationformswithStateandCountyrepresentativesduringthePARBriefing.4.Followinginitialreviewanddiscussion,theRMshouldreturntothe"BullPen",leavingtheEOFRMOPSAdvisorandEOFHPManager,andothersasneeded,toansweranytechnicalquestionsortoprovideadditionalclarification.5.ProtectiveActions-ImplementationA.TheStateandCountieswilldetermineresultingprotectiveactionstoimplement./R4 REVISIONNo.:4PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT2CSTATEANDCOUNTYPARBRIEFINGGUIDELINE(Page2of2)PAGE:28of1165.(continued)B.AssoonaspracticalafterthePARBriefing,theRMshallconsultwithDEMandCountyrepresentativesintheEOFconcerningtheactualProtectiveActionsImplemented(PAls).C.TheStateCoordinatingOfficer(SCO)shouldannouncethePAlstotheEOFstaff(theRMshouldmaketheannouncementiftheSCOisunavailable).D.Oncedetermined,thePAls(using"areas")shouldberecordedintheRMLogbookandpostedintheEOF.E.TheRMshouldnotifytheECofthePAls./R4 REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT2DDE-ESCALATIONGUIDELINES(Page1of1)PAGE:29of116Thefollowingguidelinesprovidepointstoconsiderwhende-escalationmaybeappropriate.1~ReviewtheEmergencyClassificationTablesinEPIP-01withtheEmergencyCoordinatortoassurethattheclassificationcriteriatoentertheeventarenolongerapplicable.2.Verifyadditionallythattheplantisstable,undercontrol,andtrendorprognosisindicatesthatimprovementisthemostlikelyprospect.Considerthefollowing:a.Subcriticalityb.CoreCoolingModec.HeatSinkModed.RCSPressureBoundaryIntegritye.InventoryControl(PrimaryandSecondaryCoolant)3.Verifythereisnoforeseeablelikelihoodofasignificantuncontrolledrelease.Considercontainmentpressure,containment/auxiliarybuildingradiationlevels,wastegasstoragetankpressuresandactivities,andcontainmentwatervolumesandactivities.4.Verifythatthelong-termstaffingforboththesiteandtheEOFisorganizedandinplaceasappropriatefortheevent.NOTEDe-escalationoftheeventdoesnotmeanthatprotectiveactionsforthegeneralpublicwouldterminate.ThisissueshouldbeaddressedseparatelyandspecialattentionshouldbegivenviatheENCtoensurethatpublicinformationchannelsareawareofthedifference.g,5.VerifythattheEmergencyCoordinator,EmergencyControlOfficer,DEMStateCoordinatingOfficer,CountyEmergencyManagementDirectorsandtheNRCareinformedthatde-escalationoftheemergencyclassificationisinorder./R4 REVISIONNo.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT2Eg4RECOVERYPLANNING(Page1of1)PAGE:30of116NOTETheFloridaPower8LightCompanySt.LuciePlantRecoveryPlanandotherFPLcompanyplansmaybereferencedasguidancetoassistintheorganizationofrecoveryactivities.A.Formulategeneralplansforrecoveryoperationsusingatypicaloutagemanagement/workcontrolformatandincludingthefollowingadditionalconsiderations:1.Identificationoforganization,personnel,andfacilitiestobeusedinrecoveryoperations.a.PortionsoftheEROcontinuetofunctionduringrecoveryoperationsincludingleademergencyresponsemanagers:1.EC/PlantGeneralManager2.RM/SiteVicePresidentb.Emergencyresponsefacilities(TSC,OSC,EOF)maybeusedforrecoveryactivities.2.Identificationofexternal(FPLandindustry)assistanceforinclusionintherecoveryorganization.3.IdentificationofinterfacesbetweenFPLorganizations,off-siteemergencyauthorities,regulatoryagencies,andotherapplicableorganizations.4.IdentificationofinterfacesbetweenFPLandthenewsmedia.a.CorporateCommunicationsorganizationusedduringtheemergencymayremaininplace,ifdeemedappropriate.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT3EOFRMOPSADVISOR/LOGKEEPERCHECKLIST(Page1of3)PAGE:31of116NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.AssisttheRMindeclaringtheEOFoperationalbyverifyingthefollowing:a.Minimumstaffavailableb.Communicationsequipment,proceduresandothersuppliesareavailable,checkedandreadyforuse.~CommercialphoneasbackuptoState/CountyandNRCNotifications(DONOTtestcallHRDorENS).~ExtensionphonesinEOF.~EOFpersonnelareverifyingproceduresinpositionnotebooks.c.Minimumstaffpreparedtoaccomplishmandatoryfacilityfunctionsd.ECturnovercompletedB.FACILITYOPERATION1.InitiatetheRMLogbook(useAttachment3A,TypicalInformationtobeIncludedintheRMLogbook).2.ReviewAttachment2,RecoveryManagerChecklist.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT3EOFRMOPSADVISOR/LOGKEEPERCHECKLIST(Page2of3)PAGE:32of116B.FACILITYOPERATION(continued)3.Stepstooccurcontinuallywhilethefacilityisinoperation:a.RoutinelyreviewEmergencyOperatingProcedures(EOPs)progresswiththeRMb.ContinuetolookaheadatpossibleemergencyclassificationsandPARsc.MaintaintheRMLogbookd.AssisttheRMinpreparingnotificationformsfortheStateandNRC,asnecessaryanddevelopingPARs(useEPIP-08,Off-siteNotificationsandProtectiveActionRecommendations)./R4CAUTIONResponsibilitiesnotdelegablebytheRM:~StateNotificationFormapproval~RecommendationofProtectiveActions~ExpenditureofFunds~Policysettinge.TemporarilyrelievetheRMinthe"BullPen"whenRMisinconferencef.SupporttheRMasneededorrequestedg.ProvideoperationsstatusduringPARbriefingsh.ServeasanalternateinterfacetotheNRCDSOandothermembersoftheNRCSiteTeam REVISIONNo.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT3EOFRMOPSADVISOR/LOGKEEPERCHECKLISTPAGE:33of116(Page3of3)C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.Ensuredallfacilityactivitiesclosedout.2.Ensuredallpaperworkcollected.3.ClosedouttheRMLog,returnedthelogbooktotheRMpositionnotebook.4.Providedallcompletedpaperwork(notboundinthepositionnotebook)toEmergencyPlanning.5.ReturnedpositionnotebooktoRMoffice./R4 REVISIONNO.:PROCEDURENO.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:34of116EPIP-06ST.LUCIEPLANTATTACHMENT3ATYPICALINFORMATIONTOBEINCLUDEDINTHERMLOGBOOK(Page1of1)Maintainingconcise,detailedlogsduringanemergencyeventisimportant.Followingtheevent,allinformationrecordedwillbeneededtoprovideaclearpictureofactionstaken.A.ThefollowinginformationshouldbeincludedintheRMLogbook:1.Timeofeachentry.2.Emergencyclassificationchanges.3.Notablechangesinplantconditions.4.ProtectiveActionRecommendationsandProtectiveActionsImplemented.5.Summaryofanydirectionsgiventootheremergencyresponders(whowastoldwhattodowhen).6.Summaryofdiscussions/updateswithFederal,StateandLocalagencies.7.Summaryofdiscussions/updateswithEmergencyManagers.8.Adetailedexplanationofchangestoorestablishmentofnewcompanypolicy(s).h9.Significantinformation,eventsandactionstakenrelativetotheemergencyperiodshouldberecorded.B.Logentryrequirements:1.Timeofentry.2.Useink.3.Write/printlegibly.4.Useconciseandaccuratewording.5.Strikethroughandinitialchanges.6.Donotremovepagesfromlogbook.
REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:35of116EPIP-06(Page1of3)ST.LUCIEPLANTATTACHMENT4EOFEMERGENCYTECHNICALMANAGERCHECKLISTNOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.Verifythatthefollowingpositionsarefilled:a.EOFERDADSOperator(minimumstaff)b.EOFNucFuelsEngineerc.EOFElectricalEngineerd.EOFProjectEngineere.EOFNuclearEngineerf.EOFIBCEngineerg.EOFCivilEngineerh.EOFMechEngineeri.EOFMechEngineerj.EOFStatusBoardKeeper REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:36of116EPIP-06ST.LUCIEPLANTA%I'ACHMENT4EOFEMERGENCYTECHNICALMANAGERCHECKLIST(Page2of3)B.FACILITYOPERATIONINITIAL1.InitiatetheEngineeringLogbook.2.ObtainSystemavailabilitystatusfromSystemOperations.3.Stepstooccurcontinuallywhilethefacilityisinoperation:a.ReviewneedforengineeringsupportwiththeRM.b.Logrequestsforengineeringsupport.c.AssignengineeringtasksthroughtheEOFProjectEngineer.d.ParticipateinfacilitybriefingsconductedbytheRMbyprovidingstatusofengineeringissuesandprogressoftechnicalassistance.TheformprovidedinAttachment4A,ETMActivitiesListmaybeusedtoorganizebriefinginformation.e.Ensureplantparameterandsequenceofeventsdataaremaintainedcurrentandarecorrect/reasonable.f.ManageengineeringactivitiesinsupportoftheTSC.g.Reviewtheredundancyofcriticalplantequipment.h.Evaluatethelongtermplantactionstomitigatetheconsequencesoftheevent.i.InterfacewiththeEOFHealthPhysicsManagertoresolveissuesinvolvingplantcomponentseffectingplantreleases.j.SupporttheRMduringPARBriefingstotheStateandCounties.
REVISIONNO.:4PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:37of116ATTACHMENT4EOFEMERGENCYTECHNICALMANAGERCHECKLIST(Page3of3)B.FACILITYOPERATION(continued)3.(continued)k.InterfacewiththeNRCReactorSafetyCoordinatorwhentheNRCSiteTeamarrivesattheEOF.INITIALI.PromptlyinformtheRMofengineeringrecommendations,determinations,oranalysisresults.m.SupportrecoveryplanningasrequestedbytheRMbyevaluatinglong-termplantactionstomitigatetheconsequencesoftheevent.C.FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.AIIengineeringtasks/projectsarecompletedorassignedtoaConditionReport.2.Allengineeringpaperworkiscollected.3.Alldocuments,equipment,andsuppliesreturnedtopre-activationconditionand/orlocation.4.ClosedouttheEngineeringLogbook.5.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheRM.6.ReturnedpositionnotebooktotheRMoffice./R4
REVISIONNO.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT4AETMACTIVITIESLISTPAGE:38of116c0EEOKI-IIjCllODesOOCIOCLc0Q.LOMCllDEJlOO./R4 REVISIONNO.:4PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT5EOFPROJECTENGINEERCHECKLIST(Page1of3)PAGE:39of116NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1~Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.NotifytheETMwhenfullengineeringcomplement(aslistedbelow)isavailable:a.EOFERDADSOperatorb.EOFNucFuelsEngineerc.EOFElectricalEngineerd.EOFNuclearEngineere.EOFl&CEngineerf.EOFCivilEngineerg.EOFMechEngineer(2)h.EOFStatusBoardKeeper3.Assignthefollowingset-upitemstotheEngineeringStaff:a.SynchronizeclocksintheEngineeringareawithERDADS.IncaseofERDADSfailure,synchronizewiththeaffectedControlRoom.b.Obtainpens,pencils,paperandothernecessarysuppliesfromtheAdministrationarea.
REVISIONNO.:PROCEDURENo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:40of116EPIP-06ST.LUCIEPLANTATTACHMENT5EOFPROJECTENGINEERCHECKLIST(Page2of3)B.FACILITYOPERATION1.Stepstooccurcontinuallywhilethefacilityisinoperation:a.ReviewrequestsforEngineeringSupport(useAttachment5A,EngineeringTaskandTechnicalResponseForm)withtheETM.b.Assignengineeringtasks.c.EnterengineeringtaskassignmentsonAttachment5B,EngineeringTaskList.d.Overseeprogressonassignedengineeringtaskse.Posttasks/projectsbeingworkedandstatusonstatusboardinETMoffice.f.Reviewcompletedworkforaccuracy.g.Filecompletedtasksheets(Attachment5A,EngineeringTaskandTechnicalResponseForm).h.ServeasalternateinterfacetoNRCReactorSafetyCoordinator.i.PromptlyinformtheETMofengineeringrecommendations,determinationsorresultsofanalyses.j.ProvideacopyofthecurrentAttachment5B,EngineeringTaskList,totheETMforfacilitystatusmeetings/briefings.k.SupporttheEOFETMinestablishing24-hourstaffingbycompletingAttachment5C,EngineeringShiftStaffingScheduleandprovideacopyofthecompletedformtotheEOFAdministrativeSupervisor.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT5EOFPROJECTENGINEERCHECKLIST(Page3of3)PAGE:41of116C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.Identifiedallengineeringtasks/projectstotheETMforfinalaction(s).2.Supportedrestorationofalldocuments,equipment,andsuppliestopre-activationconditionand/orlocation.3.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheETM.4.ReturnedpositionnotebooktotheRMoffice.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:42of116TO:ATTACHMENT5AENGINEERINGTASKANDTECHNICALRESPONSEFORM(Page1of1)PRIORITY:123NO:
SUBJECT:
DATE8.TIMERECEIVED:REQUEST'EQUESTER:RESPONSE'Y:VERIFIED:PROJECTS:EMERGENCYTECHNICALMANAGER:DATE8TIME:
REVISIONNO.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT5BENGINEERINGTASKLIST(Page1of1)PAGE:43of116To:RecoveryManagerFrom:EmergencyTechnicalManagerDate:~~Time:TASKNO.TaskTitle:UNITPRIORITYDATE8.TIMENO.COMPLETEAssignedTo:TaskTitle:AssignedTo:TaskTitle:AssignedTo:TaskTitle:AssignedTo:TaskTitle:AssignedTo:
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT5CENGINEERINGSHIFTSTAFFINGSCHEDULE(Page1of1)PAGE:44of116EmergencyTechnicalManagerApproved:SHIFT1SHIFT2SHIFT3toTimetoTimeEmergencyTech.Mgr.EOFPh¹DatetoDatetoDatetoProjectsEOFPh¹PlantStatusBoardEOFPh¹NuclearEOFPh¹MechanicalEOFPh¹ElectricalEOF-Ph¹I&CEOFPh¹CivilEOFPh¹FuelsEOFPh¹OtherEOFPh¹ REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT6EOFENGINEERCHECKLIST(Page1of2)PAGE:45of116NOTE1~Thischecklistappliestothefollowingpositions:EOFNuclearEngineerEOFMechanicalEngineerEOFIBCEngineerEOFNuclearFuelsEngineerEOFCivilEngineerEOFElectricalEngineer2.Whennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYAGTIVATION-INITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.IdentifyavailabilitytotheEOFProjectEngineer.B.FACILITYOPERATION1.Stepstooccurcontinuallywhilethefacilityisinoperation:a.WorktasksassignedbytheEOFETMorEOFProjectEngineer.b.ConferwithotherEOFpersonnelasneededtocompleteproblemresolutions.c.(NuclearFuels)performcoredamageassessmentinaccordancewithEPIP-11,CoreDamageAssessment.d.(NuclearFuels)providecoredamageassessmentresultstotheEOFETMandEOFHealthPhysicsManager.e.(NuclearFuels)SupportSevereAccidentManagementGuidelinesevaluationsbeingconductedintheTechnicalSupportCenter(TSC).f.KeeptheEOFProjectEngineerapprisedofstatusofworkingtasks/projects./R4 REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:46of116EPIP-06ST.LUCIEPLANTATTACHMENT6EOFENGINEERCHECKLIST(Page2of2)B.FACILITYOPERATION(continued)INITIAL1~(continued)g.Documentassessment/reviewandrecommendation/responseonAttachment5A,EngineeringTaskandTechnicalResponseForm,foreachtask/project.h.Evaluatepostedplantparameterdataforaccuracy.i.Ensuresequenceofeventsboardhassufficientdetailtounderstandeventsinprogress.C.FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.Completedallassignedtasks,asappropriate.2.Returnedalldocuments,equipment,andsuppliestopre-activationconditionand/orlocation.3.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheEOFProjectEngineer./R44.ReturnedpositionnotebooktotheRMoffice.
REVISIONNo.:PROCEDURENo.EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT7EOFERDADSOPERATORCHECKLIST(Page1of2)PAGE:47of116NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.IdentifyavailabilitytotheEOFProjectEngineer.B.FACILITYOPERATIONCAUTIONEnsuredataisbeingcollectedfortheaffectedunit.EachunithaspredesignatedERDADSterminals,oneintheengineeringareaandoneinthedoseassessmentarea.1.CheckoutERDADSterminalsanddetermineoperabilitystatus.IfERDADSisinoperableorprintoutsarenotavailable,Then:a.AssisttheEOFCommunicator(toTSC)incollectingplantparameterandradiologicaldatabycompletingAttachment10B(PlantDataSheet).b.ContactTSCERDADSTechtoreporttheproblem./R4 REVISIONNo.:4PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT7EOFERDADSOPERATORCHECKLIST(Page2of2)PAGE:48of116B.FACILITYOPERATION(continued)2.Stepstooccurcontinuallywhilethefacilityisinoperation:a.GallupEPIPscreensandadditionaldataasrequested,refertoAttachment7A,ERDADSDataAcquisition.b.ProvidethefollowingprintoutstotheEOFAdministrativeStaff:INITIAL1.St.LucieEOFDataSheet(EF1/2).2.RadioactiveGaseousSourceTerms(RG1/2)~3.Otherscreens,asrequested.c.SupportdoseassessmentbyprovidingrequesteddatafromERDADS.d.ObserveERDADSdataduringintervalbetweenreportprintingforsignificantchangesandtrends,reportchangestotheEOFETManddoseassessment,asappropriate.e.RefertoAttachment7B,ERDADSDataPoints,tothisattachmentforadescriptionofERDADdatapoints.C.FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.ERDADSsystemreturnedtopre-activationconditionpertheinstructionsontheterminal.2.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheRM.3.ReturnedpositionnotebooktotheRMoffice./R4 REVISIONNO.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT7AERDADSDATAACQUISITION(Page1of3)PAGE:49of116I.DATAACQUISITIONA.ERDADS-EmergencyResponseDataAcquisitionandDisplaySystem,thefollowinginformationisavailableonthedisplayscreensindicated.1~MeteorologicalData-Display:SMD(SiteMeteorologicalData)2.PlantParameterData-CAUTIONCertainparameters(e.g.,fanstatus)availableonUnit2areNOTavailableonUnit1.Display:intheEOF-EF(1/2)(SafetyFunctionsandEquipmentStatus)3.RadiologicalData-Display:RG(1/2)(RadiationGaseousSourceTerm)RBS(HealthPhysicsEvaluationScreen-containmentradiationlevelsandtrends)R11(AreaRadiationMonitors,Unit1)R21(AreaRadiationMonitors,Unit2)4.ChemistryData-Display:R12(S/GBlowdown,SteamJetAirEjector,Unit1)R22(S/GBlowdown,SteamJetAirEjector,Unit2)
REVISIONNO.:4PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT7AERDADSDATAACQUISITION(Page2of3)PAGE:50of116I.DATAACQUISITION(continued)A.(continued)5.Toaccessdata-1-Press"CLEAR"2-Typein"PupUnit(1/2)"3-Press"EXEC"ute,topofscreenwillread"Unitchangeiscomplete"or"CurrentUnitissameasenteredUnit"4-Press"EPIP"5-The"PAGEUP"and"PAGEDOWN"keyswillcausethefollowingdisplaysequence:SMD-RG(1/2)-SF(1/2)-RBS-EF(1/2)-SMD6.Togodirectlytoascreen-1-Press"CLEAR"2-Typeinscreendesignation,e.g.,"RG1"3-Press"DISPLAY"B.TSCCommunicator-TheTSCCommunicatorcanbeutilizedasaprimarysourceofinformationorasanalternatemethodtoERDADS.1.Primarysource-statusoffansneededfordoseassessmentexhaustfans6,7,8,9,10,15,16,and17./R4 REVISIONNo.:4PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT7AERDADSDATAACQUISITION(Page3of3)PAGE:51of116II.ERDADS-COLOR/SYMBOLCONVENTIONS~GI/SNumericvalueinwhiteondarkgreenbackgroundNumericvalueblinking(yellowonblue/redonwhite)"BAD"(blueonwhite)"FAILED""NODATA"~EDataValueisvalidandwithintheinstrumentrangeValuemaybeyellowonbluebackground(urgentalarm)orredonwhitebackground(criticalalarm),indicatesanalarmsettinghasbeenexceeded,thealarmmustbeacknowledgedintheControlRoom(operatorsareunabletoacknowledgeERDADSalarmsintheSimulatorControlRoom),thevaluewillcontinuetoblinkuntilacknowledged;thevaluewillcontinuetoupdatePrecededbyanumericvalueinwhiteonabluebackgroundsignifyingasuspectvalueindicatingthatoneorseveralinputstothiscompositepointis/areoutofinstrumentrange,whenallinputstothepointareoutofrangetheword"BAD"replacesthenumericvaluePointisfromasingleinstrumentandthevalueisoutofrangePointdoesnothaveinputtoERDADS,usuallypointavailableononeunit,butnottheother'BasedonTable4.1intheERDADSReactorOperator'sManual(8770-12058)
REVISIONNO.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT7BERDADSDATAPOINTS(Page1of8)PAGE:52of116ThefollowingdatapointdescriptionsforSt.LuciePlantcorrespondwiththedatanormallytrackedontheplantparametersstatusboard.ConsultERDADSManual,asnecessary,forverificationofpointIDs,pointnamesordescriptioninformation.POINTDESCRIPTIONAvg.RCSTHot(HLAandHLB)(deg.F)RCSPressureWR(psia)PTIDQTA541-1/2QA0501-1/2POINTNAMERCSPressureTYPECALCULATIONAverageAverageNOTESThisparameteristheaverageofthe'A'nd'B'teamgeneratorinlettemperature.Itisalsoreferredtoastheaveragehotlegtemperature.Theindividual'Aand'B'otlegtemperaturesarederivedbychoosingbetweencurrentnarrowandwiderangesensorvalues.Thechoicedependsonthecurrentvalues,qualities,anddirectionoftheratesofchangeoftheinstrumentationvalues,aswellastwopairsofoverlappingswitchinglimitsandthemostrecentrangeutilized.Theoutputsfromthecalculationconsistofthechoiceofrange,theassociatedvalue,andrateofchangetogetherwiththequalityofeach.ThisparameterisaReactorCoolantSystem(RCS)widerangeinstrument.ItderivedfromPressurizerPressuresignalsPT1107-2andPT1108.2whicharelinear.Thesesignalsareprocessedbyanaveragewithexpandedqualityalgorithm.Thisfunctionobtainstheaverageofallvalueswithagoodstatus.Italsosetsthequalityoftheresultbasedonthenumberofvalueswithgoodstatus,versusthetotalnumberofinputs.Thepossiblestatusvaluesare:Greaterthan50%ofinputshavegoodstatus,resultisgood.Onlyonegoodvalueandthetotalinputsare3ormore,theresultispoor.Whentherearenogooddatavalues,buttherearesomewithpoororsuspect,theresultispoof.Theresultissuspectforallothercasesexceptallbad,inthiscasetheresultisbad.
REVISIONNO.:PROCEDURENO.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:53of116EPIP-06ST.LUCIEPLANTATTACHMENT7BERDADSDATAPOINTS(Page2of8)POINTDESCRIPTIONPTIDRCSPressurizerQA0001-1/2Level(%)POINTNAMEPRZRLVLTYPECALCULATIONAverageNOTESThisparameterispressurizerlevel.ItisderivedfromPressurizerLevelcontrolsignalsLT1110X-2andLT1110Y-2whicharelinear.Thesetwosignalsareprocessedbyanaveragewithexpandedqualityalgorithm.Thisfunctionobtainstheaverageofallvalueswithagoodstatus.Italsosetsthequalityoftheresultbasedonthenumberofvalueswithgoodstatus,versusthetotalnumberofinputs.Thepossiblestatusvaluesare:~Greaterthan50%ofallinputshavegoodstatus,resultisgood.~Onlyonegoodvalueandthetotalinputsare3ormore,theresultispoor.~Whentherearenogooddatavalues,buttherearesomewithpoororsuspect,theresultispoor.~Theresultissuspectforallothercasesexceptallbad,inthiscasetheresultisbad.Thetopoftheheatersis73.98inchesabovethelowertopcenterline.ChargingFlowtoRegenHx(GPM)FT2212-1/2RCSCHG/MUN/AThisparameterisreactorcoolantsystemmakeupflow.Itisconvertedtoengineeringunitsusingalinearequation.SubcoolingQA0005-1/2Margin(deg.F)SubmarginMinimalThisparameterisderivedfromeightsubcooledvalues,TMARHEAD-A-1/2,TMARRCS-B-1/2,TMARUR-A-1/2,TMARHEAD-B-1/2,TMARCET-A-1/2,TMARUR-B-1/2,TMARRCS-A-1/2,andTMARCET-B-1/2,whichareprovidedbytheQualifiedSafetyParameterDisplaySystem(QSPDS).Theyareprocessedbyasignalauctioneeringminimumalgorithm.ThisfunctionfindsthehighestusabledatavalueInaspecifiedgroup.Eachdatavalueofthegroupanditsqualityisexaminedandthefollowingquantitiesareobtained:1.Lowestusabledatavalue.,2.Pointnumberofthelowestusabledatavalue,3.Numberofusabledatavalues,and4.Lowestqualityoftheusabledata.~Fortwoormoreusabledatavalues,theresultis'hehighestusablevalueandthequalityisthelowestqualityoftheusabledata.~Foronlyoneusabledatavalue,theresultissettothatvalueandthequalityispoor.~Fornousabledata,thevalueoftheresultissettothehighestofallthe(bad)dataandthequalityisbad.
REVISIONNO.:PROCEDURENO.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:54of116EPIP-06ST.LUCIEPLANTATTACHMENT7BERDADSDATAPOINTS(Page3of8)POINTDESCRIPTIONPTIDPOINTNAMETYPECALCULATIONNOTESAvg.CoreExitQA0003-1/2Temperature(degF)Temp.CoreEx.AverageThisparameterisderivedfrom45Unit1detectors,or56Unit2detectorslocatedjustabovetheupperfuelalignmentplate.TheQualifiedSafetyParameterDisplaySystem(QSPDS)providesthevalues.Theyareprocessedbyanaveragewithexpandedqualityalgorithm.Thisfunctionobtainstheaverageofallvalueswithagoodstatus.Italsosetsthequalityoftheresultbasedonthenumberofvalueswithgoodstatus,versusthetotalnumberofinputs.Thepossiblestatusvaluesare:ReactorVesselUnit1:Level(%)QA0004-1Unit2:RLEVH-2RLEVP-2Minimum~Greaterthan50%ofinputshavegoodstatus,resultisgood.~Onlyonegoodvalueandthetotalinputsare3ormore,theresultispoor.~Whentherearenogooddatavalues,buttherearesomewithpoororsuspect,theresultispoor.~Theresultissuspectforallothercasesexceptallbad,inthiscasetheresultIsbad.ThereactorvessellevelforUnit1QA0004-1isderivedfromthereactorvessellevelsRLEV-A-1andRLEV-B-1whichareprovidedbytheQualifiedSafetyParameterDisplaySystem.TheERDADSselectthelowestofthetwovalues.Foronlyonegooddatavalue,theresultissettothatvalueandthequalityispoor.ThereactorvessellevelforUnit2isdisplayedasreactorplenumlevelRLEVPB-2andreactorheadlevelRLEVHB-2whichisprovidedbythe'B'ideQualifiedSafetyParameterDisplaySystem(QSPDS).ThesetwoparametersaredisplayedwithnocalculationsbeingperformedbytheERDADScomputersystem.TheQSPDSobtainsthesevaluesfromtheheatedandunheatedjunctionthermocoupleslocatedinsidethereactor.Theyarepositionedbetweentheheadandupperfuelalignmentplatointhereactorinternals.
REVISIONNO.:PROCEDURENO.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:55of116EPIP-06ST.LUCIEPLANTATTACHMENT7BERDADSDATAPOINTS(Page4of8)POINTDESCRIPTIONReactorVesselLevel%(continued)PTIDPOINTTYPENAMECALCULATIONNOTESUnit1LevelInformation:HeadandPlenumtogetherSensorNone123456781861/41443/S108715/S505/8295/S195/8105/82019181410757Location('n.tofuelLevel~attnmenttate~dement%Valueif~Uncovered%10080614329191270Unit2LevelInformation:HeadseparatefromPlenumSensorNone123None456781701/21403/41111/8985/8745/8535/8325/8125/8522820182120192210048200100826141220Locationn.tofuelLevelValueif~atinmenttate~Sement%~Uncovered%
REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:56of116EPIP-06ST.LUCIEPLANTATTACHMENT7BERDADSDATAPOINTS(Page5of8)POINTDESCRIPTIONHPSITotalRow(GPM)PTIDHSITTLF-1/2POINTNAMEHPSIFlowTYPECALCULATIONSumNOTESThisparametermeasurestotalHPSIflowandisderivedfromHPSIHeaderFlowsignalsFT3311-1/2,FT3321-1/2,R3331-1/2andFT3341-1/2whicharesquareroots.Thesignalsareprocessedwithasumofinputsalgorithm.Thisfunctionobtainsthealgebraicsumofvalueswithagoodstatus.LPSITotalFlow(GPM)QA0908-1/2LPSIFlowSumThisparametermeasurestotalLPSIflowandisderivedfromLPSIHeaderFlowsignalsF13312-1/2,FT3322-1/2,FT3332-1/2andFT3342-1/2whicharesquareroots.Thesesignalsareprocessedbyanalgorithmwhichprovidesasumoftheinputs.Thisfunctionobtainsthealgebraicsumofvalueswithagoodstatus.ContainmentTemp.TE07-3B-1/2(deg.F)CntmntTempN/AThisparameterisacontainmenttemperatureinstrument.Itisconvertedtoengineeringunitsusingalinearequation.ContainmentQA0507-1/2PressureWR(psig)CtmntPressAverageThisparametermeasurescontainmentpressureandisawiderangeindicator.ItisderivedfromWideRangeContainmentPressuresignalsPT07-4A1-1/2andPT07-4B1-1/2whicharelinear.Theyareprocessedbyanaveragewithexpandedqualityalgorithm.Thisfunctionobtainstheaverageofallvalueswithagoodstatus.Italsosetsthequalityoftheresultbasedonthenumberofvalueswithgoodstatus,versusthetotalnumberofinputs.Thepossiblestatusvaluesare:~Greaterthan50%ofallinputshavegoodstatus,resultisgood.~Onlyonegoodvalueandthetotalinputsare3ormore,theresultispoor.~Whentherearenogooddatavalues,buttherearesomewithpoororsuspect,theresultispoor.~Theresultissuspectforallothercasesexceptallbad,inthiscasetheresultisbad.
REVISIONNO.:PROCEDURENO.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:57of116EPIP-06ST.LUCIEPLANTATTACHMENT7BERDADSDATAPOINTS(Page6of8)POINTDESCRIPTIONPTIDPOINTNAMETYPECALCULATIONNOTESContainmentSumpLevelWR(Ft.)ContainmentHydrogen(%)SGLevelAWR(%)SGLevelBWR(%)QA0008-1/2CntmntSmpWRCH2-1/2H2Conc.LT9012-1/2SGLovelALT9022-1/2SGLevelBMaximumAverageN/AN/AThisparameterisacontainmentsumpwiderangeInstrument.ItisderivedfromContainmentSumpLovelsignalsLT07-13A-1/2andLT07-13B-1/2whicharelinear.Theyareprocessedbyasignaiauctioneeringmaximumalgorithm.Thisfunctionfindsthehighestusabledatavalueinthespecifiedgroup.Eachdatavalueofthegroupanditsqualityisexaminedandthefollowingrulesareused.~Fortwoormoreusabledatavalues,theresultisthehighestusabledatavalueandthequalityisthelowestqualityoftheusabledata.~Foronlyoneusabledatavalue,theresultissettothatvalueandthequalityispoor.~Fornousabledata,thevalueoftheresultissettothehighestofallthe(bad)dataandthequalityisbad.Thisparameterisacontainmenthydrogenaverageconcentrationmeasurement.ItisderivedfromHydrogenConcentrationsignalsA.HYDROGEN-1/2andB.HYDROGEN-1/2whicharelinear.Thesesignalsareprocessedbyanaveragewithexpandedqualityalgorithm.Thisfunctionobtainstheaverageofallvalueswithagoodstatus.Italsosetsthequalityoftheresultbasedonthenumberofvalueswithgoodstatus,versusthetotalnumberofinputs.Thepossiblestatusvaluesare:~Greaterthan50%ofallinputshavegoodstatus,resultisgood.~Onlyonegoodvalueandthetotalinputsare3ormore,theresultispoor.ThisparameteristheAsteamgeneratorwiderangelevelinstrument.Itisconvertedtoengineeringunitsusingalinearequation.LTCL=LowerTapCenterLine.ThelowertapIs21inchesabovethebottomoftheUtubes.Thisparameterthe'Bsteamgeneratorwiderangelevelinstrument.Itisconvertedtoengineeringunitsusingalinearequation.LTCL=LowerTapCenterLine.Thelowertapis21InchesabovethebottomoftheUtubes.
REVISIONNO.:4PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT7BERDADSDATAPOINTS(Page7of8)PAGE:58of116POINTDESCRIPTIONPTIDPOINTNAMETYPECALCULATIONNOTESSGPressureAQA0021-1/2(psig)SGPresJARedundantSensorAlgorithmThisparameteristhe'Asteamgeneratorpressure.ItisderivedfromthreeSteamGeneratorPressureSignals,PT8013A-1/2,PT8013B-1/2,andPT8013C-1/2,whicharelinear.Thesesignalsareprocessedbyaredundantsensoralgorithm.Thisfunctionobtainstheaverageofthecurrentvaluesthathaveagoodstatusandareclosetothestatisticalmajority.SGPressureB(psig)QA0022-1/2SGPreslBRedundantSensorAlgorthimThisparameteristheBsteamgeneratorpressure.ItIsderivedfromthreeSteamGeneratorPressureSignals,PT8023A-1/2,PT8023B-1/2,andPT8023D-1/2,whicharelinear.Thesesignalsareprocessedbyaredundantsensoralgorithm.Thisfunctionobtainstheaverageofthecurrentvaluesthathaveagoodstatusandareclosetothestatisticalmajority.RefuelingWaterRWTAL-1/2TankAvg.Level(Ft)BWSTLevelAverageThisparametermeasuresrefuelingwatertanklevel.Itisderivedfromthreeinputs.TheyareLT07-2A-1/2,LT07-2B-1/2,andLT07-2C-1/2.Thesepointsareprocessedbyanaveragewithexpandedqualityalgorithm.Thisfunctionobtainstheaverageofallvalueswithagoodstatus.Italsosetsthequalityoftheresultbasedonthenumberofvalueswithgoodstatus,versusthetotalnumberofInputs.Thepossiblestatusvaluesare:~Greaterthan50%ofinputshavegoodstatus,resultisgood.~OnlyonegoodvalueandthetotalInputsare3ormore,theresultispoor.~Whentherearenogooddatavalues,buttherearesomewithpoororsuspect,theresultispoor.~Theresultissuspectforallothercasesexceptallbad,inthiscasetheresultisbad.Tankbottomreferstozerogallons.
REVISIONNO.:PROCEDURENO.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:59of116EPIP-06ST.LUCIEPLANTATTACHMENT7BERDADSDATAPOINTS(Page8of8)POINTDESCRIPTIONPTIDPOINTNAMETYPECALCULATIONNOTESCHRRM.ChannelUnit1:(R/HR)RE26-58-1(AChannel)RD26-59-1(BChannel)Unit2:RIM2640-2(AChannel)RIM26-41-2(BChannel)Cntmnt.RadMaximumThehighcontainmentradiationinstrumentsforUnit1aretheAsidemonitorRE26.58-1andthe'BsidemonitorRE26-59-1.Thesemonitorsareonlyrangecheckedandflaggedbadifoutofrange.Bothdetectorsarelocatedatthe90footcontainmentelevationandarepositionedat0and180degrees.ThehighcontainmentradiationinstrumentsforUnit2aretheAsidemonitorRIM26-40-2andthe'B'idemonitorRIM2641-2.Thesemonitorsareonlyrangecheckedandareflaggedbadifoutofrange.Bothdetectorsarelocatedatthe90footcontainmentelevationandarepositionedat0and180degrees.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT8EOFSTATUSBOARDKEEPERCHECKLIST(Page1of2)PAGE:60of116NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.IdentifyavailabilitytoEOFProjectEngineer.B.FACILITYOPERATION1.Stepstooccurcontinuallywhilethefacilityisinoperation:a.ObtainthefollowingERDADSdatasheets(printouts)fromtheEOFAdministrativeStaff:1.St.LucieEOFDataSheet(EF1/2).2.RadioactiveGaseousSourceTerms(RG1/2).b.UpdatestatusboardswithnewERDADSdata.c.Verifythatalldatahasbeenaccuratelytransferredtothestatusboards.d.Updatethesequenceofeventsboardfollowingeachfacilitybriefingandasneeded.Providerelevantinformationconcerningitemssuchas:1.Changeinclassification.2.Significantchangeinplantcondition.3.Statusofplantsystem(s)ofconcern.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT8EOFSTATUSBOARDKEEPERCHECKLIST(Page2of2)PAGE:61of116B.FACILITYOPERATION(continued)1~(continued)d.(continued)4.Injuredpersonnelstatus.5.Otheritemsofrelevantinterest.e.Makecorrections,whenidentified,bycirclingthecorrecteddata.f.Whenallstatusboardcolumns/blanksarefilled,erasethefirsttwocolumns/blanks,enternewdata,withadifferentcoloredmarker,leavingaspacebetweenthenewandtheolddata.C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.Statusboardshavebeenclearedandreturnedtopre-activationcondition.2.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheEOFProjectEngineer.3.ReturnedpositionnotebooktotheRMoffice./R4 REVISIONNo.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT9EOFNUCLEARLICENSINGMANAGERCHECKLIST(Page1of3)PAGE:62of116NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.Verifythatthefollowingpositionsarefilled:a.EOFCommunicator(4)NOTEPositionsshouldbefilledinthisorder.1.HotRingDown(HRD)Phone2.EmergencyNotificationSystem(ENS)3.TSC(directline)(shouldbefilledsecondifnoERDADSOperatorisavailable)4.HealthPhysicsNetwork(HPN)B.FACILITYOPERATION/R41~InitiatetheLicensingLogbook(useAttachment9A,TypicalInformationtobeincludedintheLogbook).$32.VerifyINPOwasnotified.3.Ensurebackupcommunicationsdevicesareavailableandoperable(workwiththeEOFAdministrativeSupervisor).
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT9EOFNUCLEARLICENSINGMANAGERCHECKLIST(Page2of3)PAGE:63of116B.FACILITYOPERATION(continued)4.Stepstooccurcontinuallywhilethefacilityisinoperation:a.Manage/superviseactivitiesofEOFcommunicators(HRD,ENS,TSC,HPN).b.EnsurecommunicationswiththeNRC(ENS,HPN)areloggedbythecommunicators.c.EnsurecoordinationwithINPOismaintainedconcerningindustryassistancerequests(ifnotbeinghandledbytheNDDO)~e.ServeasprimaryliaisonwiththeNRConcetheSiteTeamarrivesattheEOF,interfacingwiththeEmergencyResponseCoordinator.1.EnsureNRCworklocationsarefunctional.INITIAL2.CoordinatetheNRCinterfacewiththeFPLERO,andStateandCountyrepresentativesintheEOF.3.Provideaccesstonotificationforms,pressreleases,andotherinformation,asrequested.C.FACILITYCLOSEOUTANDRESTORATIONNOTEAIIpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.Allcommunicationslinksterminated.2.AIIcommunicationspaperworkcollected.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT9EOFNUCLEARLICENSINGMANAGERCHECKLIST(Page3of3)PAGE:64of116C.FACILITYCLOSEOUTANDRESTORATION(continued)3.Alldocuments,equipment,andsuppliesreturnedtopre-activationconditionand/orlocation.4.ClosedouttheLicensingLogbook.5.PreparedIncidentReport(formatavailableinFloridaPower8LightNuclearPlantRecoveryPlant)forreviewandapprovalbyRM.6.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheRM.7.ReturnedpositionnotebooktotheRMoffice.INITIAL/R4 REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:65of116ATTACHMENT9ATYPICALINFORMATIONTOBEINCLUDEDINTHELOGBOOK(Page1of1)Maintainingconcise,detailedlogsduringanemergencyeventisimportant.Followingtheevent,allinformationrecordedwillbeneededtoprovideaclearpictureofactionstaken.A.ThefollowinginformationshouldbeincludedintheLogbook:1.Keyevents(e.g.,classificationchanges,injuries,etc.).2.Statuschangesinequipment,radiologicalconditions,personnel,etc.3.Decisionsmadeoractionstaken.4.Otheritemsofsignificance.B.Logentryrequirements:1.Timeofentry.2.Useink.3.Write/printlegibly.4.Useconciseandaccuratewording.5.Strikethroughandinitialchanges.6.DonotremovepagesfromLogbook.
REVISIONNo.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT10EOFCOMMUNICATORCHECKLIST(Page1of4)PAGE:66of116NOTE1.ThischecklistappliestoallEOFCommunicatorpositionsasfollows:HRDCommunicatorTSCCommunicatorENSCommunicatorHPNCommunicator2.Whennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.NOTEThefirstEOFCommunicatortoarriveattheEOFshouldidentifyhimself/herselftotheRM.2.IdentifyavailabilitytotheEOFLicensingManager.3.ReviewAttachment10A,CommunicationsGuidelines.4.(TSC)RequestcopyoftheECLog,completednotificationforms(StateandNRC)andchecklists,andotherpertinentinformationbetransmittedtotheEOF./R4 REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT10EOFCOMMUNICATORCHECKLIST(Page2of4)PAGE:67of116B.FACILITYOPERATIONINITIAL1.(HRD)CompleteturnoverwithTSCHRDCommunicator,assumeresponsibilityforState/Countynotifications.2.(ENS)CompleteturnoverwithTSCENSCommunicator,assumeleadresponsibilityforNRCnotifications.3.(TSC)EstablishdirectlinelinkwithTSC.4.(HPN)EstablishconnectiononNRCHPconferencebridge.5.Stepstooccurcontinuallywhilethefacilityisinoperation:HRDCommunicationsa.AssisttheRMwithStateandCountynotificationsby:1.ReviewingtheStatenotificationforms(theFloridaNuclearPlantEmergencyNotificationandtheSupplementalDataSheet,Attachments1and2respectivelyinEPIP-08,Off-siteNotificationsandProtectiveActionRecommendations)forcompleteness.2.Asnecessary,ensuringProtectiveActionRecommendations(PARs)matchthePARsWorksheet(seeAttachment3,DeterminationofProtectiveActionRecommendations(PARs)inEPIP-08).3.EnsuringtheRMhasapprovedtheform.b.TransmitthenotificationformsinaccordancewithAppendixC,NotificationsFromtheEmergencyOperationsFacility(EOF)inEPIP-08.c.RequesttheEOFRMOPSAdvisor/Logkeeperlognotificationtimes./R4/R4/R4 REVISIONNo.:4PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT10EOFCOMMUNICATORCHECKLIST(Page3of4)PAGE:68of116B.FACILITYOPERATION(continued)5.(continued)NOTEInitialcontactwiththeNRCrequiresuseoftheNRCReactorPlantEventNotificationWorksheet(Attachment4toEPIP-08)notificationform.ControlRoomorTSCpersonnelmayhavealreadyaccomplishedthistask.TheENSCommunicatorwillneedtoensurethataninitialNRCnotificationformhasbeencompleted./R4ENS/HPNCommunicationsa.Maintainanopenlineofcommunicationandatransmissionlog.b.(ENS)Ensurenotificationsareinitiatedwithin1hour(immediatelyfollowingStateandCountynotification)ofaclassification/PARchangeorothersignificantevent.RefertoAppendixCinEPIP-08ifadditionalinformationisneeded./R4c.RequesttheEOFRMOPSAdvisor/Logkeeperlognotificationtimes.d.LogallquestionsaskedbyNRC.e.ObtainanswerstoquestionsfromappropriateEOFManager.f.ObtainRMapprovalpriortoprovidingadditionalinformationtotheNRC.TSCCommunicationsa.MaintainanopenlineofcommunicationwiththeTSC.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT10EOFCOMMUNICATORCHECKLIST(Page4of4)PAGE:69of116B.FACILITYOPERATION(continued)5.(continued)b.IfERDADSisoutofservice,obtainplantparameterandradiologicaldata(useAttachment10B,PlantDataSheetandRadioactiveGaseousSourceTerms)throughphoneconversationwiththeTSC(viatheTSCEOFCommunicator).c.ClarifyanydiscrepantinformationwiththeTSC(viatheTSCEOFCommunicator),as-requested.C.FACILITYCLOSEOUTANDRESTORATIONINITIAL/R4/R4NOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.Allcommunicationlinks(HRD,ENS,HPN,TSC)terminated.2.Allcommunicationspaperworkcollected.3.Allphoneequipmentreturnedtopre-activationcondition.4.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheEOFNuclearLicensingManager.5.ReturnedpositionnotebooktotheRMoffice./R4 REVISIONNO.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT10ACOMMUNICATIONSGUIDELINES(Page1of8)PAGE:70of116I.GeneralGuidelines1.Alwaysspeakclearly,firmly,andwithnormaltonewhenusinganycommunicationssystem.2.Thesenderandreceivershallbeclearlyidentified.3.Messagetext:a.Communicationmustbefreeofambiguity.Slangtermsshallnotbeused.Avoidtheuseofwordsthatsoundalike;forexample,avoidincreaseanddecrease,useraiseandlowerinstead.b.Communicationsmustbespecific.Usenounnamesforplantequipment,notacronyms;forexampleuselowpressuresafetyinjectionpumpinsteadofLPSI.c.Thephoneticalphabetwillbeusedtoidentifyspecifictrain,bus,channel,.orequipmentdesignations,notjustletteridentifier;forexample,refertothe1Alphaheaterdrainpump,notthe1Aheaterdrainpump.Thefollowingisthephoneticalphabettobeused:AAlphaBBravoCCharlieDDeltaEEchoFFoxtrotGGolfHHotelIIndiaJJulietKKiloLLimaMMikeNNovember0OscarPPapaQQuebecRRomeoSSierraTTangoUUniformVVictorWWhiskeyXXrayYYankeeZZulu/R4d.Thephoneticalphabetshouldnotbeusedforstringedletterreferences,acceptableacronyms,orlocationsymbols;forexample,ABbus,ACorDC,TSC,respectively.
REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:71of116EPIP-06ST.LUCIEPLANTATTACHMENT10ACOMMUNICATIONSGUIDELINES(Page2of8)I.GeneralGuidelines(continued)4.Acknowledgementandconfirmation(3-waycommunication)-messagesshallbecomprisedofpropertransmission,acknowledgement,andconfirmation.a.Themessageisproperlytransmittedfromtheoriginatortothereceiver.b.Themessagereceivershallacknowledgethecommunicationbygivingafunctionalrepeat-backtothemessageoriginator.Therepeat-backcanbeprovidedbyeitherparaphrasingorexplainingthemessageinone'sownwords,orbyverbatimrepeat-back.Inallcases,verbatimrepeat-backshallbeusedforequipmentidentifiers.c.Ifthemessagereceiverdoesnotunderstandthemessagehe/sheshallaskforthemessagetoberepeated.d.Ifanincorrectrepeat-backisgiven,themessageoriginatorshallimmediatelycorrectthemiscommunicationwithastatementsuchas,"WRONG",followedbyrestatingthecorrectmessage.e.Themessageoriginatorshallconfirmtheacknowledgement(repeat-back)withastatementsuchas,"Thatiscorrect".5.UseofaCallSignisnotnecessarywhencommunicatingwiththeHPOff-siteChannelradio(stationIDoccursevery30minutesautomatically).6.TheCallSignshouldbecommunicatedperiodicallywhenusingtheLGR.
REVISIONNo.:4PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT10ACOMMUNICATIONSGUIDELINES(Page3of8)PAGE:72of116I.GeneralGuidelines(continued)7.Priortotransmission,ensurethatinformationhasbeenverifiedandapprovedbytheappropriateauthority,asnecessary.8.EnsurethatanyincomingpertinentinformationisprovidedtotheRecoveryManageroranRMOPSAdvisor/Logkeeper.9.Maintaindocumentationofanysignificantinformationprovidedorreceived.II.CommunicationsSstemsHRDCommunicatorA.StateWarningPoint(SWP)HotRingDownPhone(HRD)1.ThisistheprimarycommunicationspathwaytotheStateWarningPointandSt.LucieandMartinCounties.2.Aself-verifyingphonesystemwhichisinitiatedbyenteringthe3digitcodecorrespondingtothedesiredlocationofcontact.ThephonedialinglocationcodesareavailableintheSt.LuciePlantEmergencyResponseDirectory(ERD)~Aconfirmationring-back(doubletone)willbeheardifthedialedterminalissuccessfullycontacted.Whenthepartyanswers,begintransmissionbydepressingthe"push-to-talk"barinthehandset.Releasethe"push-to-talk"bartoreceiveresponse.
REVISIONNO.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT10ACOMMUNICATIONSGUIDELINES(Page4of8)PAGE:73of116II.CommunicationsSstems(continued)1.(continued)B.CommercialTelephone1.ThisisthefirstalternatecommunicationspathwaytotheStateWarningPointandSt.LucieandMartinCounties.2.EOFTelephoneSystema.LongDistanceCalls(off-network):8+1+areacode+sevendigitnumber+authorizationcode(ifprompted)C.EmergencySatelliteCommunicationsSystem(ESATCOM)1.ThisisthesecondalternatecommunicationspathwaytotheStateWarningPointandSt.LucieandMartinCounties.2.AbackupcommunicationssystemtotheStateandCounties.Toinitiatetransmission,liftthehandsetanddepressthe"push-to-talk"barinthehandset.Wait3-5secondstohearabeepbeforestartingtotalk.Theredlightonthephoneisapowerindicator,whenlit,powerisavailable.
REVISIONNO.:4PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT'IOACOMMUNICATIONSGUIDELINES(Page5of8)PAGE:74of116II.CommunicationsSstems(continued)1.(continued)D.LocalGovernmentRadio(LGR)-CALLSIGN:KILONOVEMBERGOLFROMEO8-7-4(KNGR874)1~ThisisthethirdalternatecommunicationspathwaytotheStateWarningPointandSt.LucieandMartinCounties.2.AbackupcommunicationssystemtotheCountiesandindirectlytotheState.Thesystemhastwolowbandradiofrequencies.ThereareseparateMotorolaCommandSeriestableradios,onesettotheprimarychannel,F2(39.180Mhz,Statechannel1)andtheothersettothesecondarychannel,F1(39.100Mhz,Statechannel2).Theradioscanbeoperatedeitherbydepressingthe"transmit"button-ontheconsoleorbyremovingthehandsetanddepressingthe"push-to-talk"barinthe.handset.The"xmit"lightislitduringtransmission.(Preferenceshouldbegiventousingthehandset).2.ENSCommunicatorA.EmergencyNotificationSystem(ENS)1.ThisistheprimarycommunicationspathwaytotheNRC.2.TheENSispartoftheNRCEmergencyTelecommunicationsSystem(ETS).InitiatecontactbydialingoneofthephonenumbersprovidedonthephoneofintheSt.LuciePlantEmergencyResponseDirectory(ERD).TheENSwillbecomeanopenlineofcommunicationatanALERTorhigheremergencyclass.TheTSCshouldmaintainthatopenlineuntiltheEOFisadequatelystaffed,thenboththeTSCandEOFshouldstayontheline./R4 REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT10ACOMMUNICATIONSGUIDELINES(Page6of8)PAGE:75of116II.CommunicationsSstems(continued)2.(continued)B.CommercialTelephone1.ThisisthebackupcommunicationspathwaytotheNRC.2.EOFTelephoneSystema.LongDistanceCalls(off-network):8+1+areacode+sevendigitnumber+authorizationcode(ifprompted)3.TSCCommunicatorA.TSCDirect-lineTelephone1.ThisisadirectlinetotheTechnicalSupportCenter(TSC).InitiatecontactbyremovingthehandsetfromthecradlewhichwillcausethephoneintheTSCtoring.Whenthephoneisanswered,begintransmission.ThislinkcanalsobeinitiatedfromtheTSC.4.HPNCommunicatorA.HealthPhysicsNetwork(HPN)1.TheHPNispartoftheNRCEmergencyTelecommunicationsSystem(ETS).TheHPNwillbecomeopenlineofcommunicationatanALERTorhigheremergencyclass.InitiatecontactbydialingoneofthephonenumbersprovidedintheSt.LuciePlantEmergencyResponseDirectory(ERD).RequestthattheNRCOperationsCenter(NRCOC)dutyofficerestablishtheHPNBridgeforSt.LuciePlant.IftheTSChasalreadyestablishedthebridge(withtheNRCOC),requesttobeaddedon./R4 REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT10ACOMMUNICATIONSGUIDELINES(Page7of8)PAGE:76of116III.OtherCommunicationsSstems1.EOFTelephoneSystemA.St.LuciePlant:For4000and7000numbers;Dialthe4digitextensionFor3000numbers;Dial9+465-3550+the4digitextensionB.NetworkofInteroffice:8+FPLnetworknumber(example-totheGO8+552-XXXX)C.Intrafacility:Dialthe4digitextensionD.LocalCalls(off-network):9+outside7digitnumberE.LongDistanceCalls(off-network):8+1+areacode+7digitnumber+authorizationcode(onthephone)F.LocalDirectoryAssistance9+411 REVISIONNo.:4PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT10ACOMMUNICATIONSGUIDELINES(Page8of8)PAGE:77of116III.OtherCommunicationsSstems(continued)2.HPOff-siteRadioChannelA.Aunique900Mhzchannelforcommunicationswiththeoff-sitefieldmonitoringteams.TheTSChastheprimaryresponsibilityforcommunicatingwiththefieldteamsanduseofthisradiointheEOFisonlyasabackuptotheTSC.TheradioisaMotorolaSpectrawhichhasbeensetupsothattheHPOff-siteChannelisthe"home"channel.1~Topower-uptheradio:a..Plugthepower.cordintothe.walloutletbehindthetable.b.Presstheredbuttononthespeakerbox(AstronRS-12S)totheupposition,buttonwillilluminate.c.Depressthe"pwr"buttonontheSpectraradio.2.Tooperatetheradio:a.Depressthetransmitside(withthelightningbolt)ofthemicrophonebaseandbegintransmission.
REVISIONNO.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT10BPLANTDATASHEET(Page1of3)ERDADSEF112ScreenMimicPAGE:78of116AvgRCSTholRCSPrzProsRCSPrzLvlChargingRowUmilingSubcooiingMrgnAverageCETRxVesselLvlHPSIFlowLPSIFlowCTMTTempCTMTPres(WR)CTMTSumpLvl(NR)CTMTH2S/GLovel(WR)AS/GLevel(WR)8S/GPressureAS/GPressure8RWTLevelCHRRMCh.ACHRRMCh.8SAFEGUARDSHPSIAHPSI8LPSIALPSI8CHGPUMPACHGPUMP8CHGPUMPCCTMTCOOLERACTMTCOOLER8CTMTCOOLERCCTMTCOOLERDCCWACCW8CCWCFEEDWATERSOURCEMAINFWPAMAINFWP8AFWAAFW8AFWCAMAINFEEDFLOW8MAINFEEDFLOWAAUXFEEDFLOW(GPM)8AUXFEEDFLOW(GPM)CAUXFEEDFLOW(GPM)ELECTRICALSYSTEMS4160A3(VOLTS)416083(VOLTS)6900A1(VOLTS)690081(VOLTS)CIRCULATIONRCPA1RCPA2RCPBlRCP82LPSIALPSI8LPSIA1FLOWLPSIA2FLOWLPSI81FLOWLPSI82FLOWAVOLTSVOLTSAMPS(EPIPOSB.WPG)EMERGENCYDIESELGENERATORS REVISIONNO.:4PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT10BPLANTDATASHEET(Page2of3)ERDADSRG1ScreenMimicPAGE:79of116WINDSPEEDWINDDIRECTIONAIRTEMPDIFFTEMP10METER57.9METERMPHMPHDEGDEGDEGFDEGFDEGF/50METERCHANNELMAINSTEAMVALUEUNITSCHANNELCONTAINMENTVALUEUNITS05-01AMAINSTMMR/HR58AHlRANGER/HR05-02BMAINSTMMR/HR59BHlRANGER/HRPRESSUREPSIGCHANNELECCS1AVALUEUNITSCHANNEL02-05LOWRANGEuC/cc01-0502-07MIDRANGEuC/cc01-0702-09HlRANGEUC/cc01-0902-10FLOWSCFM01-10CHANNELECCS1BVALUEUNITSCHANNEL03-05LOWRANGEuC/cc04-0503-07MIDRANGEuC/cc04-0703-09HIRANGEuC/cc04-0903-10FLOWSCFM04-10PLANTVENTLOWRANGEMIDRANGEHlRANGEFLOWFUELBLDGLOWRANGEMIDRANGEHlRANGEFLOWVALUEUNITSuC/ccUC/ccuC/ccSCFMVALUEUNITSuC/ccuC/ccuC/ccSCFM/R4 REVISIONNO.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT10BPLANTDATASHEET(Page3of3)ERDADSRG2ScreenMimicPAGE:80ofI16WINDSPEEDWINDDIRECTIONCURRENTTEMPDIFFTEMP10METER57.9METERMPHMPHDEGDEGDEGFDEGFDEGFCHANNELMAINSTEAMVALUEUNITSCHANNELCONTAINMENTVALUEUNITS631AMAINSTMMR/HR40AHIRANGER/HR632BMAINSTMMR/HR41BHlRANGER/HR633BACKGROUNDMR/HRPRESSUREPSIGCHANNELECCS2AVALUEUNITSCHANNELPLANTVENTVALUEUNITS601LOWRANGEuC/cc621LOWRANGEuC/cc602'IDRANGEUC/cc622MIDRANGEuC/cc603HlRANGEUC/cc623HlRANGEuC/cc=604EFFLUENTuC/SEC624EFFLUENTUC/SECCHANNELECCS28VALUEUNITS611LOWRANGEuC/cc612MIDRANGEuC/cc613HlRANGEuC/cc614EFFLUENTuC/SEC/R4
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT11COUNTYTECHNICALADVISORCHECKLIST(Page1of2)PAGE:81of116NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.IfarrivingatEOF:a.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.b.IdentifyavailabilitytotheEIM.c.TakeacopyofyourchecklistwhendispatchedtotheCounty.ORIfarrivingattheEmergencyOperation'sCenterorhavingbeendispatchedfromtheEOF:a.IntroduceyourselftotheEOCstaff.b.ContacttheEOFandnotifyTheEIMoranEIM/ENCTechnicalAdvisorofyourcontactphonenumber.c.Requestacopyofyourchecklistbetelecopiedtoyou.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT11COUNTYTECHNICALADVISORCHECKLIST(Page2of2)PAGE:82of116B.FACILITYOPERATION1.Stepstooccurcontinuallywhilethefacility(EOC)isinoperation:a.Provideoverviewofaccidentconditionsandplantstatus.b.AnswertechnicalquestionsandaddclarificationofissuesnotunderstoodintheEOC.INITIALc.ContactpersonnelintheEOFforassistanceinobtaininginformation(usetheERD).d.Participateinfacility(EOC)briefings,asrequested.C.FACILITYCLOSEOUTANDRESTORATION1.DebriefedwithEOCManager.2.Collectedallgeneratedpaperwork.3.ClosedoutwiththeEIMorEIM/ENCTechnicalAdvisor.4.ReturnpositionnotebookandcompletedpaperworktoEmergencyPlanningassoonaspossible.
REVISIONNo.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT12EOFHEALTHPHYSICSMANAGERCHECKLIST(Page1of3)PAGE:83of116NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.Verifythatthefollowingpositionsarefilled:a.EOFDoseAssessor/FMTCoord(3)b.EOFHPTechSupportc.EOFRadStatusBoardsKeeperB.FACILITYOPERATION1.InitiatetheHPLogbook.2.ConductaturnoverwiththeTSCChemistrySupervisorpriortocommencingdoseassessment.3.ConductaturnoverwiththeTSCHPSupervisorpriortotakingovertheFieldMonitoringTeams.4.RequestthatclocksintheDoseAssessmentareabesynchronizedwithERDADS.IncaseofERDADSfailure,synchronizewiththeaffectedControlRoom.5.Stepstooccurcontinuallywhilethefacilityisinoperation:a.Monitorradiologicalconditionsassociatedwiththeemergency.b.ManagethedoseassessmentandfieldmonitoringactivitiesintheEOF.
REVISIONNo.:PROCEDURENo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:84of116EPIP-06ST.LUCIEPLANTATTACHMENT12EOFHEALTHPHYSICSMANAGERCHECKLIST(Page2of3)B.FACILITYOPERATION(continued)5.(continued)c.RoutinelyupdatetheRMonradiological/meteorologicalconditionsandpotentialimpacttotheevent.d.AssisttheRMindeterminingPARsbaseonradiologicalconditions(useAttachment3,DeterminationofProtectiveActionRecommendations(PARs)inEPIP-08,Off-siteNotificationsandProtectiveActionRecommendations)./R4e.AssisttheEOFRMOPsAdvisor/RMindeterminingthe"Off-siteReleaseSignificanceCategory"ascalledforontheStateNotificationForm,asnecessary./R4f.ReviewemergencydoseextensionswiththeRMandtheEC(useAttachment12A,ExposureLimitsforEmergencyResponsePersonnel)./R4g.ProvidetechnicalsupporttoEOFCommunicators.h.InterfacewiththeEOFETMtoresolveissuesinvolvingplantcomponentsaffectingplantreleases.i.ProvideradiologicalinformationtosupporttheEOFEIMandtheEmergencyNewsCenter(ENC).j.InterfacewiththeStateBureauofRadiationControl.k.KeeptheRMabreastofthestatusofBureauofRadiationControlactivities.I.InterfacewiththeNRCProtectiveMeasuresCoordinatorwhentheNRCSiteTeamarrivesonsite.m.SupportrecoveryplanningasrequestedbytheRM.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT12EOFHEALTHPHYSICSMANAGERCHECKLISTPAGE:85of116(Page3of3)C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.AllradiologicalassessmentactivitiesintheEOFhavebeenterminated.2.AllHPpaperworkiscollected.3.Alldocuments,equipment,andsuppliesreturnedtopre-activationconditionand/orlocation.4.ClosedouttheHPLogbook.5.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheRM.6.ReturnedpositionnotebooktotheRMoffice./R4 REVISIONNO.:PROCEDURENO.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:86of116EPIP-06ST.LUCIEPLANTATTACHMENT12Ag2,$4EXPOSURELIMITSFOREMERGENCYRESPONSEPERSONNEL(Page1of1)NOTE1.BothTotalDose(TEDE)andThyroidDose(CDE)shouldbeusedforpurposesofcontrollingexposure.2.Protectiveclothing,includingrespirators,shouldbeusedwhereappropriate.Forthefollowingmissions,theexposurelimitis"':TotalDose"'HYROID"'TEDE)(CDE)Performanceofactionsthatwouldnotdirectlymitigatetheevent,minimizeescalation,orminimizeeffluentreleases.5REM50REMPerformanceofactionsthatmitigatetheescalationtotheevent,rescuepersonsfromanon-lifethreateningsituation,minimizeexposuresorminimizeeffluentreleases.10REM'-100REMPerformanceofactionsthatdecreasetheseverityoftheeventorterminatetheprocessescausingtheeventinanattempttocontroleffluentreleasestoavoidextensiveexposureoflargesituation.25REM250REM(Volunteers"'houldbeabovetheageof45.)(5)(5)(1)Exposurelimitstothelensoftheeyeare3timestheTotalDose(TEDE)valueslisted.(2)TotalDose(TEDE)isthetotalwholebodyexposurefrombothexternalandinternal(weighted)sources-TotalEffectiveDoseEquivalent.(3)ThyroidDose(CDE)commitmentfrominternalsources-CommittedDoseEquivalent.Thesamedoselimitsalsoapplytootherorgans(CDE),skin(ShallowDoseEquivalent)andextremities(ExtremityDoseEquivalent).(4)Volunteerswithfullawarenessofrisksinvolvedincludingnumericallevelsofdoseatwhichacuteeffectsofradiationwillbeincurredandnumericalestimatesoftheriskofdelayedeffects.(5)NoupperlimitforTotalDose(TEDE)and/orThyroidDose(CDE)exposurehasbeenestablishedbecauseitisnotpossibletoprejudgetherisksthatonepersonshouldbeallowedtotaketosavethelifeofanother.Also,nospecificlimitisgivenforthyroidexposuresinceintheextremecase,completethyroidlossmightbeanacceptablesacrificeforalifesaved.Thisshouldnotbenecessaryifrespiratorsand/orthyroidprotectionforrescuepersonnelareavailableastheresultofadequateplanning./R4 REVISIONNo.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT13EOFDOSEASSESSOR/FMTCOORDCHECKLIST(Page1of2)PAGE:87of116NOTE1.TheresponsibilitiesoftheFMTCoordinatorareprovidedinEPIP-10,Off-SiteRadiologicalMonitoring.2.Whennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.IdentifiedavailabilitytoRM(serveasinitialEOFHPManager)ORIdentifiedavailabilitytoEOFHPManager.B.FACILITYOPERATIONNOTE1.InitialoperatinginstructionsforuseoftheClassAModelareprovidedinEPIP-09,Off-SiteDoseCalculations.2.IfthecomputerizedClassAModelisnotavailable,doseassessmentshallbeconductedinaccordancewithEPIP-09.1.EstablishcommunicationlinkwiththeTSCDoseAssessor.2.RequestallpreviousdosecalculationpaperworkfromtheTSC.3.CompleteClassAModelQCcheck.
REVISIONNo.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT13EOFDOSEASSESSOR/FMTCOORDCHECKLIST(Page2of2)PAGE:88of116B.FACILITYOPERATION(continued)4.Stepstooccurcontinuallywhilethefacilityisinoperation:a.ObtaininputdatafortheClassAModelfromtheEOFERDADSOperator(RG1/2Screen)~b.CoordinatedoseassessmentwiththeTSC.INITIALc.ProvidestatusboardupdateinformationtotheEOFRadStatusBoardkeeper(usethe"StatusBoard"printoutfromtheClassAProgram.d.CoordinatedoseassessmentwiththeStateBureauofRadiationControl.e.Review/comparefieldmonitoringresultswithdosecalculations.f.ReportdoseassessmentresultstotheEOFHPManager.C.FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.Alldoseassessmentactivitiesterminated.2.TSCcommunicationslinkterminated.3.Alldocuments,equipment,andsuppliesreturnedtopre-activationconditionand/orlocation.4.Allpaperworkcollected.5.Providedallcompletedpaperwork(notboundinthepositionnotebook)toEOFHPManager.6.ReturnedpositionnotebooktotheRMoffice./R4 REVISIONNo.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT14EOFHPTECHSUPPORTCHECKLIST(Page1of2)PAGE:89of116NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.IdentifyavailabilitytoEOFHealthPhysicsManager.B.FACILITYOPERATION1.SynchronizeclocksintheHPareawithERDADS.IncaseofERDADSfailure,synchronizewiththeaffectedControlRoom.2.Stepstooccurcontinuallywhilethefacilityisinoperation:a.Assistindoseassessmentand/orfieldmonitoringactivities,asneeded.b.EnsureHPdatapostedonstatusboardsarecurrent.c.ProvidesupporttotheEOFHealthPhysicsManagerasrequested.d.SupporttheEOFHealthPhysicsManagerinestablishing24hourstaffing,reportstaffingtotheEOFAdministrativeSupervisor.e.ProvideHPtechnicalinformation/supporttotheEmergencyNewsCenter(ENC)andassistwithpressbriefings,asnecessary.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT14EOFHPTECHSUPPORTCHECKLISTPAGE:90of116(Page2of2)C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.AssistedwithterminationofallHPactivitiesintheEOF/ENC.2.Alldocuments,equipment,andsuppliesreturnedtopre-activationconditionand/orlocation.3.Providedallcompletedpaperwork(notbound'inthepositionnotebook)totheEOFHPManager.4.ReturnedpositionnotebooktotheRMoffice./R4 REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT15EOFRADSTATUSBOARDKEEPERCHECKLIST(Page1of2)PAGE:91of116NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.IdentifyavailabilitytotheEOFHealthPhysicsManager.B.FACILITYOPERATION1.VerifyHPEmergencyKitinventory.2.Stepstooccurcontinuallywhilethefacilityisinoperation:a.ObtaindatafromtheEOFDoseAssessorandEOFFMTCoordinator.b.Updatestatusboardswithnewradiologicaldata.c.Verifythatalldatahasbeenaccuratelytransferredtothestatusboards.d.Makecorrections,whenidentified,bycirclingthecorrecteddata.e.Whenallstatusboardcolumns/blanksarefilled,erasethefirsttwocolumns/blanks,enternewdata,withadifferentcoloredmarker,leavingspacebetweenthenewandtheolddata.
REVISIONNO.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT15EOFRADSTATUSBOARDKEEPERCHECKLISTPAGE:92of116(Page2of2)C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.Statusboardshavebeenclearedandreturnedtopre-activationcondition.2.EquipmentandsupplieshavebeenreturnedtotheHPEmergencyKit.3.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheEOFHPManager.4.ReturnedpositionnotebooktotheRMoffice./R4 REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT16EOFADMINISTRATIVESUPERVISORCHECKLIST(Page1of3)PAGE:93of116NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.IdentifyavailabilitytotheRecoveryManager.3.DirectanEOFAdministrativestaffmembertopostallEPIPrevisionnumbersonthestatusboard.4.Ensurefacilitypublicaddresssystemisturnedon(amplifierinAdministrationarea,Room102)andconductatestpageusingtheRMmicrophone.a.CoverageincludestheBullpenandthesurroundingofficeareas.b.CoverageDOESNOTincludetheEmergencyNewsCenter(ENC).5.Ensurethe"Videolink"systemisturnedon.a.TurnonthemastervideoswitchlocatedintherackmountcabinetinRoom132(key014inkeybox).b.Inthe"Bullpen"turnonthetwotelevisionsetsusingtheremotecontrols(oneforeachtelevisionset)ontheRMtable.c.Setthechannelselectortochannel7andadjustvolume.
REVISIONNo.:4PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT16EOFADMINISTRATIVESUPERVISORCHECKLIST(Page2of3)PAGE:94of116B.FACILITYOPERATIONINITIAL1.Ensureprocedures,otherdocumentsanddrawingsareavailableandtherevisionnumbersverified.2.Stepstooccurcontinuallywhilethefacilityisinoperation:a.ManageEOFAdministrativeStaff.b.Ensurephotocopiers,telecopiers,computers,printers,andtelephonesaremaintainedoperable.c..Supervisedistributionofalldata,notificationforms,andotherinformation.d.Facilitatedistribution-ofclerical-suppliestoall=groupsintheEOF.e.Coordinatewithfacilitymanagersordesignee,toestablish24hourstaffingandcompletingAttachment2A,EOFEROShiftStaffing,EmergencyResponseOrganizationandShiftStaffing,(allpositionsshouldbefilled,exceptasauthorizedbytheRM).f.Ensurearrangementsforfood,water,andothernecessitiesaremadefornext48to72hours,ifnecessary.g.ArrangeforhotelreservationsandcarrentalsforincomingpersonnelasdirectedbytheRM.h.WorkwiththeRMforauthorizationfortheexpenditureoffunds.
REVISIONNo.:4PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT16EOFADMINISTRATIVESUPERVISORCHECKLISTPAGE:95of116(Page3of3)C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.Supervisedfacilitywalkthroughtoensurealldocuments,equipment,andsupplieswerereturnedtopre-activationconditionand/orlocation.2.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheRM.3.ReturnedpositionnotebooktotheRMoffice./R4 REVISIONNo.:4PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT17EOFADMINISTRATIVESTAFFCHECKLIST(Page1of3)PAGE:96of116NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.IdentifyavailabilitytotheEOFAdministrativeSupervisor.3.Verifyproceduresbypostingrevisionnumbersonthestatusboard.Postallprocedures(EPIP,HP,Chem).ConsultControlCopy1intheRecoveryManager'sOfficeorfollowthestepsbelowtoprintoutanEPIPlist.a.InLotusNotes,clickonthePSLProceduresIcon.b.OntheSearchlinetoolbar,clickthefarrightbutton(with2circlesandadownarrow).c.SelectGroupSearchfromthedropdownmenu.d.IntheSearchlinetype"EP"(wherethe"XX"is).e.ClickSearchorhitEnter.f.EPIPlistisnowdisplayed(notinanyparticularorder).g.Toprintthelist:ClickFile.SelectPrintfromthedropdownmenu.SelectViewOptionsinthedialoguebox.ClickOK.
REVISIONNo.:PROCEDURENO.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:97of116EPIP-06ST.LUCIEPLANTATTACHMENT17EOFADMINISTRATIVESTAFFCHECKLIST(Page2of3)B.FACILITYOPERATION1.AIIphotocopiers,telecopiers,computers,printers,etc.energizedandproblemsreportedtoEOFAdministrativeSupervisor.2.Switchboardphonemanned.3.Establishlogforincoming/outgoingtelecopiers,usingAttachment17A,TelecopyLog.4.-Stepstooccurcontinuallywhilethefacilityisinoperation:a.ProvideclericalsuppliestoallgroupsintheEOF,asneeded.b.Producerequired/requestedcopies,retainoriginals.c.Distributecopies,telecopies,etc.torecipientsasquicklyaspossible(e.g.,ERDADSdatasheets,notificationforms,newsreleases,etc.).d.ProvideanyincomingtelecopymaterialstotheRM,RMOPSAdvisor/Logkeeperorasdesignatedonthecoverpage.e.AssisttheEOFAdministrativeSupervisorinestablishing24hourstaffing.f.PerformdutiesassignedbytheEOFAdministrativeSupervisor.
REVISIONNO.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT17EOFADMINISTRATIVESTAFFCHECKLISTPAGE:98of116(Page3of3)C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.Allphotocopiers,telecopiers,computers,printers,etc.de-energizedandproblemsreportedtoEOFAdministrativeSupervisor.2.Conductedfacilitywalkthroughtoensurealldocuments,equipment,andsupplieswerereturnedtopre-activationconditionand/orlocation.3.EOFphoneswitchboardsetto"nightcall".4.Providedcompletedpaperwork(notboundinthepositionnotebook)totheEOFAdministrativeSupervisor.5.ReturnedpositionnotebooktotheRMoffice./R4 REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT17AEOFTELECOPYLOG(Page1of1)PAGE:99of116IncomingOutgoingPhoneNumber:Date:~~Message4DescriptionReceivedFromTimePagesReceivingOperator:
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:100of116ATTACHMENT18EOFEMERGENCYSECURITYMANAGERCHECKLIST(Page1of3)NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.IdentifyavailabilitytotheRM.g,3.EstablishcontrolstoensureallEOFpersonnelcomplywiththerequirementsoftheFitnessforDutyRule.4.Verify-operability-oftheintoxilyzer.5.EnsureEOFsecurityforce-established.B.FACILITYOPERATION1.EstablishaccesscontrolfortheEOFandEmergencyNewsCenter(ENC).2.ContacttheTSCSecuritySupervisor.a.Establishresponsibility/protocolfornotificationofoff-siteauthoritiesregardingthestatusofsiteevacuation.3.InitiatetheSecurityLogbook.4.Stepstooccurcontinuallywhilethefacilityisinoperation:a.AdviseRMonsecurityrelatedmatters.b.ProvideliaisonfunctionbetweenlocallawenforcementandrescueagenciesandFPLforissuessuchas:1.Bombthreatsoractsofterrorism.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:101of116ATTACHMENT18EOFEMERGENCYSECURITYMANAGERCHECKLIST(Page2of3)B.FACILITYOPERATION(continued)4.(continued)b.(continued)2.Membersofthepublicorthemediaarrivingatthesite.INITIAL3.Siteegressandingress.4.Fireorrescue/medicalresponse.c.CoordinatesafeguardssuspensionwiththeTSCSecuritySupervisor.d.Monitorsiteaccountabilitystatus.e.InterfacewithNRCSafeguards/SecurityCoordinatorwhentheNRCSiteTeamarrivesattheEOF.f.Trackstatusofinjuredpersonneltakentoanoff-sitemedicalfacility(useAttachment18A,InjuredPersonReport).g.MaintaintheSecurityLogbook.C.FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.Allpaperworkcollected.2.Closedoutwiththelocallawenforcementagencies.3.ClosedoutSecurityLogbook.
REVISIONNo.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:102of116ATTACHMENT18EOFEMERGENCYSECURITYMANAGERCHECKLIST(Page3of3)C.FACILITYCLOSEOUTANDRESTORATIONINITIAL4.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheRM.5.ReturnedpositionnotebooktotheRMoffice.6.Allaccessbadgesreturnedtopre-activationlocation.7.Facilitysweepcompleted.8.Facilitylockedandalarmset./R4 REVISIONNO.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT18AINJUREDPERSONREPORT(Page1of1)PAGE:103of116NAME:EMPLOYER:0FPL0OTHER(astcompanynemo)JOBDESCRIPAON:TIMEINJURED:TIMEREPORTED:NATUREOFINJURY:LOCATIONWHEREINJUAYOCCURRED:0NO0YESTRANSPORTEDTOHOSPITAL'?ISTHEVICTIMCONTAMINATED2WHATBODYPARTSCONTAMINATEO2HOWTRANSPORTED?LEVELOFCONTAMINATIONAREALEVEIOPMCPMAREALEVEIDPMCPMAREALEVEIDPMCPMNAMEOFHOSPITALOAOTHERLOCATION0NO0YESACTIVITYATTHETIMEINJURYOCCURREDCURREMTMEDICALCONDITIONMISC.INFO,NAME:EMPLOYER0FPL0OTHER(Estcompanyname)JOBDESCRIPllON:TIMEINJURED:TIMEREPORTED'ATUREOFINJUAY:LOCATIONWHEREINJURYOCCURRED:0NO0YESTRANSPORTEDTOHOSPITAL?ISTHEVICTIMCONTAMINATED7WHATBODYPARTSCONTAMINATED'7HOWTAANSPORTED7LEVELOFCOMl'AMINATIONAREALEVEIDPMCPMAREALEVEIDPMCPMAREALEVEIDPMCPMNAMEOFHOSPITALOROTHERLOCATION0NO0YESACTIVITYATTHETIMEINJUAYOCCURREDCURRENTMEDICALCONDmONMISC.INFO.
REVISIONNO.:4PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT19NUCLEARDIVISIONDUTYOFFICERCHECKLIST(Page1of2)PAGE:104of116NOTE1.ThefollowinginformationisprovidedwhenrespondingintheEOF.2.Whennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.B.FACILITYOPERATION1.InitiatetheEmergencyControlOfficer(ECO)Logbook.2.NotifyINPOthatanAlert(orhigher)emergencyclasswasdeclared.3.Stepstooccurcontinuallywhilethefacilityisinoperation:a-.-Maintain=24-hour.per-dayon-callavailability.b.ServeasatechnicaladvisorfortheECO.1.ServeasadvisortotheEIMontechnicalmattersthatmayaidintheformationofnewsreleases.2.ServeasadvisortotheGAM,RiskManager,ortoStateandCountyagenciesontechnicalmatters.3.MakenotificationsfortheECO,asdirected.4.Serveas"interimECO"intheEOFduringperiodsoftimewhentheECOleavesthefacility.
REVISIONNo.:4PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT19NUCLEARDIVISIONDUTYOFFICERCHECKLIST(Page2of2)PAGE:105of116B.FACILITYOPERATION(continued)3.(continued)c.MaintainarecordoftheeventandactivitiesintheECOLogbook(useAttachment19A,TypicalInformationtobeIncludedintheECOLogbook).d.RequestthatINPOassistFPLbyperformingthefollowing:1.Asrequested,submitpressreleasesoverNuclearNetwork.INITIAL2.PromptlyinformFPLofanymediainquiriesorindustryofferstoprovideassistancebycontactingyou(NDDO)intheEOF(orotherlocation)atyournumber.3.RecordallconversationswithINPOindetailintheECOLogbook.C.FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.TerminatedassistancetotheECO.2.Collectedallpaperwork.3.ClosedouttheECOLog,returnedtheLogbooktotheECOpositionnotebookoffice.4.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheRM.5.ReturnedpositionnotebooktotheRMoffice./R4 REVISIONNO.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTPAGE:106of116ATTACHMENT19ATYPICALINFORMATIONTOBEINCLUDEDINTHEECOLOGBOOK(Page1of1)Maintainingconcisedetailedlogsduringanemergencyeventisveryimportant.Followingtheevent,allinformationrecordedwillbeneededtoprovideaclearpictureofactionstaken.RegulatoryagencieswillusethisinformationtoevaluatetheadequacyofmitigativeandcorrectiveactionstakenbytheEmergencyResponders:ThefollowinginformationshouldbeincludedintheECOLogbook:Timeofeachentry.SummaryofanydirectionsgiventootherEmergencyResponders(i.e.,whowastoldwhattodowhen).SummaryofdiscussionswithEmergencyManagers.SummaryofdiscussionswiththePresident-NuclearDivision.DonotremovepagesfromtheLogbook.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT20EMERGENCYCONTROLOFFICERCHECKLIST(Page1of2)PAGE:107of116NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.B.FACILITYOPERATION1.Stepstooccurcontinuallywhilethefacilityisinoperation:a.Approvenewsreleases.b.ServeasofficialspokespersonfortheNuclearDivision.c.EnsuretheRMisawareoftheprimaryconcernsofthemedia/public.d.Actasthechiefnuclearofficer.e.KeeptheRMabreastofactivitiesinvolvingtheGovernmentalAffairsManagerandRiskManager,iftheyarenotintheEOF.f.Maintainawarenessofplantstatusandradiologicalconditions.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT20EMERGENCYCONTROLOFFICERCHECKLIST(Page2of2)PAGE:108of116C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.SpokespersonresponsibilitieshavebeenreturnedtoCorporateCommunications.2.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheRM.3.ReturnedpositionnotebooktotheRMoffice./R4/R4 REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT21GOVERNMENTALAFFAIRSMANAGERCHECKLIST(Page1of2)PAGE:109of116NOTE1.ThefollowinginformationisprovidedwhenrespondingintheEOF.2.Whennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATION1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.Verifythatthefollowingarenotified:a.GovAffairsRep(Tallahassee)b.Governor'sAdvisorc.GovernmentalAffairsAssistantINITIALd.AviationDepartmentB.FACILITYOPERATIONNOTETheliaisonfunctionbetweentheECOandpublicofficialsisaccomplishedbytheGAMinconjunctionwiththeGovernmentalAffairsAssistant,GovernmentalAffairsRepresentativeinTallahasseeandtheGovernor'Advisor.1.Stepstooccurcontinuallywhilethefacilityisinoperation:a.Shareinformationalupdates.b.ReferanyspecificquestionsorcommentsfromelectedorpoliticalauthoritiestotheECO.
REVISIONNo.:PROCEDURENO.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT21GOVERNMENTALAFFAIRSMANAGERCHECKLIST(Page2of2)PAGE:110of116B.FACILITYOPERATION(continued)1.(continued)c.ReportsummariesofinterfacewithgovernmentalofficialsroutinelytotheECO.d.PromptlyreportrumorsthatcouldsignificantlyimpactemergencyresponsecapabilitytotheECO.e.Keepalogofallsignificantinformation.C.FACILITYCLOSEOUTANDRESTORATIONINITIAL1.Alloff-siteinterfaceshavebeendiscontinued.2.TurnoverandcloseoutprovidedtotheECOregardingliaisonactivitieswithoff-siteofficials.3.Allpaperworkcollected.4.AllcompletedpaperworkforwardedtoEmergencyPlanning.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT22EMERGENCYINFORMATIONMANAGERCHECKLIST(Page1of3)PAGE:111of116NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIALRefertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.2.ObtainanupdatefromtheECOorRM.3.Re-establishcontactwiththeEmergencyNewsCenter(ENC)Manager.4.Re-establishcontactwiththe"acting"EIM.5.Resumeresponsibilityforallcommunications,asappropriate.6.DeterminewhensufficientstaffispresenttohandleallfurthermediabriefingsfromtheENC.7.RecommendtotheECOthattheENCshouldbedeclaredoperational:OperationalatB.FACILITYOPERATION1.RequestthatclocksintheENCbesynchronizedwithEOF(basedonERDADS).2.IssueanewsreleaseannouncingoperationoftheENC,itslocationandthemediaphonenumber.3.EnsureaCountyTechnicalAdvisorisdispatchedtoSt.LucieandMartinCounties.4.DirectanEIM/ENCTechnicalAdvisortokeepLogbook.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT22EMERGENCYINFORMATIONMANAGERCHECKLIST(Page2of3)PAGE:112of116B.FACILITYOPERATION(continued)5.Stepstooccurcontinuallywhilethefacilityisinoperation:a.Whendevelopingupdates,subsequentstatementsand/ornewsreleases,obtainapprovalfromtheECO.b.CoordinatereviewswithState,CountyandFederalrepresentativesintheEOF.c.EnsurethatallFPLnewsreleasesaredeliveredtotheEOFAdministrativeStafffordistributiontotheappropriateagencies(includingtheCorporateCommunications(CC)staffinJunoBeach).d.EnsurethatallFPLnewsreleasesaredeliveredtotheENCandsharedamongtheparticipantsinthejointnewscenterpriortobriefings.e.Conductnewbriefings(useAttachment22A,NewsBriefingGuidelines,tothisattachment)~f.AttendEOFbriefingsandmeetings,especiallythosecalledtodetermineStateandCountyProtectiveActionRecommendations(PARs)ifpossible.
REVISIONNo.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT22EMERGENCYINFORMATIONMANAGERCHECKLISTPAGE:113of116(Page3of3)C.FACILITYCLOSEOUTANDRESTORATIONINITIALNOTEAsnecessary,continuedinterfacewiththemediashouldbeinaccordancewithstandardCorporateCommunicationsprocedures.NOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1.MedianotifiedofENCdeactivation.2.ENCreturnedtopre-activationcondition.3.CountyTechnicalAdvisorsrecalled.4.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheRM./R4 REVISIONNo.:4PROCEDURENo.:PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYPAGE:114of116EPIP-06ST.LUCIEPLANTATTACHMENT22ANEWSBRIEFINGGUIDELINES(Page1of1)NOTETheseguidelinesaretakenfromtheCorporateCommunicationsNuclearEmergencyPlan(CCNEP).Foradditionalinformation,theCCNEPshouldbeconsulted.1~IncoordinationwiththeENCManager,scheduleandmoderatemediabriefingsintheENCMediaBriefingRoom.2.ThesebriefingsshouldbeproceededbyabriefingintheENCtodeterminethefollowing:A.WhohasannouncementsB.WhattheannouncementsareC.Whatprioritytheyshouldbein3.Briefingsshouldbeconductedeveryhour.4.UsetheECO,otherFPLdecisionmakers,FPLtechnicalstaffandrepresentativesfromState,CountyandFederalemergencyagenciesasspokespersons.5.UseFPL'stechnicaladvisorstoconductbackgroundbriefingsbetweennewsbriefings,asappropriate.6.Duringthebriefing,referthemedia'squestionstotheagencyhavingjurisdictionofthesubjectofthequestion.
REVISIONNO.:PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT23EIM/ENCTECHNICALADVISORCHECKLIST(Page1of2)PAGE:115of116NOTEWhennecessaryorappropriate,stepsofthischecklistmaybeperformedoutofsequence.A.FACILITYACTIVATIONINITIAL1.Refertosection5.0ofthisprocedure(includedinthepositionnotebook)andreviewthegeneralinstructions.B.FACILITYOPERATION1.InitiatetheEIMLogbook.2.Stepstooccur-continuallywhilethefacilityisinoperation:a.GatherinformationandensuretheEIMisup-to-dateontheemergencystatusinthefollowingareas:EmergencyClassificationsCorrespondingEmergencyActionLevels(EALs)AssociatedProtectiveActionRecommendations(PARs)Plantconditionsandparametersb.AssisttheEIMwithinterpretingtechnicaldatatoensureaccuracyofnewsreleases.c.AssistinobtainingdatafromtheEOFstaffforuseinnewsreleases,asneeded(payparticularattentiontoupdatesofradiologicalinformationthroughdoseassessment).
REVISIONNo.:4PROCEDURENo.:EPIP-06PROCEDURETITLE:ACTIVATIONANDOPERATIONOFTHEEMERGENCYOPERATIONSFACILITYST.LUCIEPLANTATTACHMENT23EIM/ENCTECHNICALADVISORCHECKLIST(Page2of2)PAGE:116of116B.FACILITYOPERATION(continued)2.(continued)d.Verifythatyouareontheroutinglistsforthefollowinginformation:INITIALHP/ChemistrydataETM/ERDADSupdatesNuclearlicensing/communicationsdatae.Reviewcontentofnewsreleasesfortechnicalaccuracy.f.EnsurethattheENCisreceivingaccurate,up-to-dateinformationneededformediabackgrounders.g.Conducttechnicalbriefings,asrequested.C.FACILITYCLOSEOUTANDRESTORATIONNOTEAllpaperworkcompletedinthepositionnotebookshouldremaininthepositionnotebook.1~AssistedEIMinENCcloseout.2.Returnedalldocuments,equipmentandsuppliestopre-activationconditionand/orlocation.3.ClosedouttheEIMLog,returnedLogbooktotheEIMpositionnotebook,andreturnedthenotebooktotheRMoffice.4.Providedallcompletedpaperwork(notboundinthepositionnotebook)totheEIM.5.ReturnedpositionnotebooktoRMoffice./R4
~'%@gIII'IA TitleFPLST.LUCIEPLANTEMERGENCYPLANIMPLEMENTINGPROCEDURESAFETYRELATEDProcedureNo.EPIP-08CurrentRevisionNo.EffectiveDate06/15/01OFF-SITENOTIFICATIONSANDPACTIONRECOMMENDATIOTECTIVEPSLResponsibleDepartment:EMERGENCYPLANNINGREVISIONSUMMARY:Revision3-THISPROCEDUREHASBEENCOMPLETELYRENVM'0instructionsfornotificationbyclarifyingresponsibilities8revisingnotificationchecklists,improvedPARinstructionsbycreatingseparateattachment,relocatedprocedureinformation,addedinstructionsforalternateMETdata,addedcautionregardingclassificationofmultipleevents,addednotetoControlRoomappendixidentifyingattachmentsnecessarytocompletenotificationchecklists,andmadeeditorialandadministrativechanges.(J.R.Walker,06/11/01)Revision2-AddednewNRCNotificationformandrevisedtitleofformthroughoutprocedure.ClarifiedturnoverresponsibilitiesbetweenECandRM.DeletedECturnoverguidance(includinginECprocedure).ImprovedoverviewinformationregardingPARs.AddedreferencetoNUREG-1022.Clarifiedinstructionsfordetermining"timecontactmade."AddednotesidentifyingtheavailabilityofinformationfromprintoutsoftheClassAmodeltoassistincompletionofoff-sitenotificationforms.UpdateddirectionsforcompletionofNRCNotificationForm.Madeadministrative/editorialchanges.(R.Walker,01/18/01)Revision1-THISPROCEDUREHASBEENCOMPLETELYREWRITTEN.Addeddefinition,instructionsectionandaddedguidanceonpreparingthesupplementaldatasheet.RemovedECorRMsignaturefromthePARworksheets,deletedcautionandinstructionstoreviewpreviouslyissuedPARSandmadethesupplementaldatasheetarequireddocumentfornotificationswith60-minutetimelimits.(S.Knapp,09/11/00)Revision0Revision3FRGReviewDate05/30/00FRGReviewDate06/07/01ApprovedByR.G.WestPlantGeneralManagerApprovedByR.G.WestPlantGeneralManagerN/ADesignatedApproverN/ADesignatedApprover(MinorCorrection)ApprovalDate05/31/00ApprovalDate06/11/01SQPSDATEDQCTPROCEDUREDQCNEPIP-08SYSCQMCOMPLETEDITM3 II~C4 REVISIONNO.:PROCEDURENO.:EPIP-08SECTIONPROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTTABLEOFCONTENTSPAGE:2of58PAGE1.0PURPOSE.
2.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTS.......93.0RESPONSIBILITIES4.0DEFINITIONS5.0INSTRUCTIONS5.1StateandCountyNotification.5.2NuclearRegulatoryCommission(NRC)Notification5.3ErroneousInformation.APPENDICES.10.13.13~~~~~~~~~16.17APPENDIXANOTIFICATIONSFROMTHEAFFECTEDCONTROLROOM.....18APPENDIXBNOTIFICATIONSFROMTHETECHNICALSUPPORTCENTER(TSC).APPENDIXCNOTIFICATIONSFROMTHEEMERGENCYOPERATIONSFACILITY(EOF)~ATTACHMENTS24.30ATTACHMENT1FLORIDANUCLEARPLANTEMERGENCYNOTIFICATIONFORM..38ATTACHMENT1ADIRECTIONSFORCOMPLETINGTHEFLORIDANUCLEARPLANTEMERGENCYNOTIFICATIONFORM......39ATTACHMENT2SUPPLEMENTALDATASHEET..45ATTACHMENT2ADIRECTIONSFORCOMPLETINGTHESUPPLEMENTALDATASHEET.46ATTACHMENT3DETERMINATIONOFPROTECTIVEACTIONRECOMMENDATIONS(PARs).50 REVISIONNo.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTTABLEOFCONTENTS(continued)PAGE:3of58SECTIONATTACHMENTS(continued)ATTACHMENT4NRCREACTORPLANTEVENTNOTIFICATIONWORKSHEET.ATTACHMENT4ADIRECTIONSFORCOMPLETINGTHENRCREACTORPLANTEVENTNOTIFICATIONWORKSHEET...............PAGE.5557 REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:4of581.0PURPOSE1.1DiscussionThisprocedureprovidesinformationandinstructionsforundertakingnotificationsoftheStateWarningPoint(SWP)andtheNuclearRegulatoryCommission(NRC)andfordeterminationofProtectiveActionRecommendations(PARS).2.3.4.ThisprocedureisforuseintheControlRoom,TechnicalSupportCenter(TSC)andEmergencyOperationsFacility(EOF).UpondeclarationofanemergencyclassificationtheNuclearPlantSupervisor(NPS)assumesthedutiesoftheEmergencyCoordinator(EC)~TheEChasinitialresponsibilityforoff-sitenotiTicationsandPARs.OncetheEOFisoperationalandproperturnoverhasbeenconducted,theRecoveryManager(RM)assumesresponsibilityforoff-sitenotificationsandPARsfromtheEC.5.6.AtanAlertorhigherlevelemergency,communicationswiththeNRCtransitiontoanopenphonelinefromtheTSCandtheEOF(ataSiteAreaEmergencyofhigherlevelemergency).ThefollowingtableillustrateswhichfacilityhasaresponsibilityforClassification,NotificationorPARs.ClassificationsNotificationsPARsControlRoom(XuntilECfunctiontransferstotheTSCXtransfersmXtransfers->Xtransfers-+TSC(Xwhenoperational)XXtransfersmXtransfers->EOF(Xwhenoperational)7.Off-siteNotificationA.PurposeofOff-SiteNotificationsFPLisrequiredtonotifyoff-siteagenciesintheeventofanyemergencythatcouldthreatenthehealthandsafetyofthepublic.Thesenotificationsprovideanearlywarningtoagenciesresponsibleforpublicprotection.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:5of581.1Discussion(continued)7.(continued)NOTETheStateDepartmentofHealth(BureauofRadiationControl)maynothavetheirofficestaffedona24-hourbasis.IntheeventthattheydonotanswertheHotRingDown(HRD)telephone,theStateWarningPointSWPassumesresonsibilitfornotifintheirdutofficer.B.WhoShallBeNotifiedStateDivisionofEmergencyManagementStateDepartmentofHealth(BureauofRadiationControl)St.LucieCountyEmergencyOperationsCenterMartinCountyEmergencyOperationsCenterNRCStateandCountyNotification80StateandlocalagenciesarenotifiedbyusingtheHotRingDown(HRD)telephone.TheHRDringstheStateWarningPoint(SWP).TheSWPputstheotheragenciesonlineandreducestheneedforindividualcalls.tt4AftertheStateCoordinatingOfficer(SCO)arrivesintheEOF,he/shecantransfer"NETControl"totheEOF.Whenthisoccurs,theRecoveryManager'sPARBriefingbecomestheprimarynotificationmethodfortheStateandCounties.TheFloridaNuclearPlantEmergencyNotificationForm(formsimilartoAttachment1)andtheSupplementalDataSheet(formsimilartoAttachment2)shouldstillbecompletedandprovidedtotheSCOorhis/herdesigneeintheEOF.TheEOPHRDCommunicatorshouldnolongercontacttheStateWarningPoint(SWP).
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:6of581.1Discussion(continued)7.B.(continued)2.NRCNotificationa.b.TheNRCisnotifiedusingtheEmergencyNotificationSystem(ENS)telephone.NRCnotificationsoccurthroughanopenlineofcommunicationintheTSCand,whenoperational,theEOF.C.EmergencyFollow-upInformationRequestsfromStateandlocalagencies.2.3.IncomingcallsshouldcomeviatheSWPovertheHRDphone.IftheHRDisinoperable,theSWPmayusecommercialtelephoneorESATCOM(emergencysatellitephone).Ifanoff-siteauthoritycontactstheplantwithoutgoingthroughtheSWP,requestthattheycontacttheSWP.SWPshallverifythattheagencycallingisariskcountyortheDepartmentofHealth(DOH)andshallnotifyothercountyandstateagenciesoftheupdatedinformation,thusreducingthenumberofcallsthatmaybedirectedtotheplant.Long,detailedexplanationsofplantsystemsorreactortheoryshouldbeavoided.IfpromptedforthiskindofinformationbytheStateDutyOfficer,he/sheshouldbereferredtotheNuclearDivisionDutyOfficer(NDDO).IftheStateoroneoftheCountiesprovideseithertheTSCorEOFwithneworpertinentinformation,ThenbringthatinformationtotheattentionoftheECorECAssistant/LogkeeperintheTSCortheRMortheRMOPSAdvisor/LogkeeperintheEOF.
REVISIONNO.:PROCEDURENo.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:7of581~1Discussion(continued)8.ProtectiveActionRecommendationsA.ProtectiveactionsforthegeneralpublicareordinarilyNOTrequiredpriortodeclarationofaGeneralEmergency.Itispossiblehowever,thatduetounusuallystableandconstantmeteorologicalconditions,protectiveactionscouldberecommendedataSiteAreaEmergencybasedonprojecteddoses.Thisistheexceptionratherthantherule.B.ProtectiveactionsforthegeneralpublicarerequiredtoberecommendedifaGeneralEmergencyisdeclared.InitialProtectiveActionRecommendations(PARs)arenormallybasedonplantconditions.ThiswouldNOTbetrueiftheGeneralEmergencywasdeclaredbasedonoff-sitedose(eithermeasuredorprojected)oraSecurityEmergency(pertheSecurityPlan).ThepredeterminedminimumPARs(basedonplantconditions)areasgivenbelow.GeneralEmergency-MinimumPARs1.InanycasewhereaGENERALEMERGENCYhasbeendeclared,theminimumPARshallbe:Shelterallpeoplewithina2-mileradiusandoutto5milesinthesectorsaffected.Thesectorsaffectedareatleastthree,thedownwindsectorplusthetwoadjacentsectors.IfaGENERALEMERGENCYhasbeendeclaredduetoactualorprojectedseverecoredamage,theminimumPARshallbe:Evacuateallpeoplewithina2-mileradiusfromtheplantandoutto5milesinthesectorsaffected.Shelterallpeopleintheremainingsectorsfrom2to5milesandfrom5to10milesfromtheplant.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:8of581.1Discussion(continued)B.(continued)3.IfaGENERALEMERGENCYhasbeendeclaredduetolossofphysicalcontroloftheplanttointruders,includingtheControlRoomoranyotherarea(s)vitaltotheoperationofthereactorsystem(asdefinedintheSecurityPlan),theminimumPARshallbe:C.Evacuateallpeoplewithina2-mileradiusfromtheplantandoutto5milesinthesectorsaffected.Shelterallpeopleintheremainingsectorsfrom2to5milesandfrom5to10milesfromtheplant.Onceareleaseofradioactivematerialoccurs,doseassessmentshouldbeutilizedwhenevaluatingPARs.ThefinaldeterminationofthePARshouldconsiderallavailableinformationincludingoff-sitedoseprojections,plantconditionsandfieldmonitoringdata.Themostconservativerecommendationshallbemade.D.IfitisanticipatedthataPARthresholdwillbeexceeded,DONOTwaituntilthethresholdisexceededtomakethatPAR.
REVISIONNO.:PROCEDURENo.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:9of5
82.0REFERENCES
/RECORDSREQUIRED/COMMITMENTDOCUMENTSNOTEOneormoreofthefollowingsymbolsmaybeusedinthisprocedure:IndicatesaRegulatorycommitmentmadebyTechnicalSpecifications,ConditionofLicense,Audit,LER,Bulletin,OperatingExperience,etc.andshallNOTberevisedwithoutFacilityReviewGroupreviewandPlantGeneralManagerapproval.ttIndicatesamanagementdirective,vendorrecommendation,plantpracticeorothernon-regulatorycommitmentthatshouldNOTberevisedwithoutconsultationwiththeplantstaff.'PIndicatesastethatreuiresasinoffonadatasheet.2.1References1.St.LuciePlantUpdatedFinalSafetyAnalysisReport(UFSAR)Unit1andUnit22.St.LuciePlantTechnicalSpecificationsUnit1andUnit23.g1St.LuciePlantRadiologicalEmergencyPlan(E-Plan)4.E-PlanImplementingProcedures(EPIP00-13)5.St.LuciePlantEmergencyResponseDirectory(ERD)6.QI-17-PSL-1,QualityAssuranceRecords2.2RecordsRequiredAllPARworksheetsandnotificationsforms(allattachments)shallbemaintainedinplantfilesinaccordancewithQI-17-PSL-1~2.3CommitmentDocumentstt1PMAIPM96-04-165,"ITR96-006"(UnusualEventDeclaredDuetoDroppedRod)2.$2PMAIPM96-09-185,ConditionReportCR-96-1750(Off-siteNotificationUsingCommercialPhone)(continuedonnextpage)
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:10of582.33.03.13.23.33.43.53.63.7CommitmentDocuments(continued)3.'ttsNRCInspectionReport91-01,ClosureofIFls89-31-03and89-31-014.g4ConditionReportCR-00-0428(EvaluatedExerciseCritique)5.$sPMAIPM96-05-233(Off-siteNotificationProcess)6.ltdPMAIPM99-09-016(PARsBasedonFMTData,CompletionofNRCNotificationForm)7.gsNUREG-1022,EventReportingGuidelines10CFR50.72and50.73,Section4.2.4,ENSEventNotificationWorksheet(NRCForm361).8.$9ConditionReportsCR-01-0726andCR-01-0742(NOUEsAssociatedwithSDCDuringSL1-17Outage)9.'ttq0ConditionReportCR-01-0389(AlternateMetDataSource)RESPONSIBILITIESEmergencyCoordinator-Responsibleforclassifications,notificationsandPARs.RecoveryManager-ResponsiblefornotificationsandPARs.DutyCallSupervisor-AssiststheECwithfilling-outthenotificationformsandperformingnotificationsfollowingECapproval.TSCECAssistant/LogkeeperorTSCOPSCoordinator-Preparesnotificationforms(Attachment1,FloridaNuclearPlantEmergencyNotificationForm,Attachment2,SupplementalDataSheet,andifnecessaryAttachment4,NRCReactorPlantEventNotificationWorksheets)forECapprovalwhentheTSCisoperational.EOFRMOPSAdvisor/Logkeeper-Preparesnotificationforms(Attachment1,Attachment2andifnecessaryAttachment4)forRMapprovalwhentheEOFisoperational.TSCHRDCommunicator-AssiststheTSCECAssistant/LogkeeperorTSCOPSCoordinatorwithnotificationformpreparationandmakescallstocompletenotificationstotheSWP.EOFHRDCommunicator-AssiststheEOFRMOPSAdvisorwithformpreparationandmakescallstocompletenotificationstotheSWPandtheSCOfollowingtransferofNetControlbytheDivisionofEmergencyManagement(DEM).
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:11of583.8TSCChemistrySupervisor(inhisabsence,TSCDoseAssessor)-AssiststheECwithradiologicaldoseassessmentdataandPARS.3.9EOFHPManager(inhisabsence,EOFDoseAssessor)-AssiststheRMwithradiologicaldoseassessmentdataandPARS.3.10TSCSupervisor-OverseescommunicationsperformedbytheTSCCommunicators(HRD,ENS,HealthPhysicsNetwork(HPN),Sound-PoweredPhonetalker,EOFandFieldMonitoringTeam).3.11EOFNuclearLicensingManager-OverseesEOFcommunicationsperformedbytheEOFCommunicators(HRD,ENS,HPNandTSC).3.12InformationServices-Maintainsusercopies,intheUnit1andUnit2ControlRooms,ofthefollowingchecklistandsupportingattachmentsformakingnotificationsanddevelopingProtectiveActionRecommendations:AppendixA,NotificationsfromtheAffectedControlRoomAttachment1-FloridaNuclearPlantEmergencyNotificationFormAttachment1A-DirectionsforCompletingtheFloridaNuclearPlantEmergencyNotificationFormAttachment3-DeterminationofProtectiveActionRecommendations(PARs)Attachment4-NRCReactorPlantEventWorksheetAttachment4A-DirectionsforCompletingtheNRCReactorPlantEventWorksheet4.0DEFINITIONS4.1Conservative-Meansmoreextensiveorcomprehensiveactionunderagivensetofcircumstancestoprovideagreatermeasureofsafety.Forexample,evacuationismoreconservativethansheltering.4.2Emergency-Anyoff-normaleventorconditionwhichisclassifiedintooneofthefouremergencyclasses(UnusualEvent,Alert,SiteAreaEmergency,orGeneralEmergency)bytheNPSinaccordancewithEPIP-01,ClassificationofEmergencies.
REVISIONNO.:PROCEDURENo.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:12of584.34.4EmergencyCoordinator(EC)-ThetitleinitiallyassumedbytheNPS,untilrelievedbyplantmanagementthroughproperturnover,intheeventofplantconditionsthattriggerimplementationoftheEmergencyPlan.TheECisresponsiblefornotifyingoff-siteauthorities,emergencyrespondersbothinsideandoutsidethecompanyandhasfullauthorityandresponsibilityforon-siteemergencyresponseactions.TheECisalsoresponsibleforProtectiveActionRecommendationsduringtheinitialstagesofanemergency.FloridaNuclearPlantEmergencyNotificationForm-ApredeterminedformatusedbynuclearpowerplantsthroughouttheStatefornotificationandlocalauthorities.4.5Operational(statusforanemergencyfacility)-Themandatoryminimumstaffispresentandthefacilityhastakenresponsibilityforitsprocedurallyassignedfunctions.4.64.74.8ProtectiveActionRecommendations(PARs)-Recommendations,foractioninstructionstoprotectthepublic,madebytheEmergencyCoordinatororRecoveryManagertoStateandCountyofficials.FPLmayrecommendNoAction,ShelteringorEvacuation.RecoveryManager(RM)-Adesignatedcompanyofficerorseniormanager,whowillhaveresponsibilityforthedirectionandcontroloftheEOF.He/shehastheauthoritytoestablishpolicyandtoexpendfundsnecessarytocopewithemergencysituationsthattriggertheimplementationoftheEmergencyPlan.Release(duringanydeclaredemergency)1.Anyeffluentmonitorincreaseof(approximately)10timesoronedecadeabovepre-transientvalues.OR4.92.HealthPhysicsdetectingairborneradioactivitylevelsinexcessof25%derivedairconcentration(DAC)outsideofplantbuildingsduetofailureofequipmentassociatedwiththedeclaredemergency.StateNotificationForm(SNF)-Lessformal,moreconciseexpressionusedinlieuofFloridaNuclearplantEmergencyNotificationForm.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:13of585.0INSTRUCTIONS5.1StateandCountyNotificationTimeLimitsA.Notificationshallbeinitiatedwithin15minutesofanyofthefollowing:B.1~RecognitionofentryintotheEmergencyPlan.2.EscalationinEmergencyClass.3.De-escalationoftheEmergencyClass.4.ProtectiveActionRecommendation.5.ChangeinProtectiveActionRecommendation.Notificationshallbeinitiatedwithin60minutesofanyofthefollowing:AtanAlertorhigherEmergencyClass,thetimeofthelastupdate(unlessadifferentfrequencyhasbeenagreedtobytheoff-siteagenciesasduringahurricane).2.3.Aradiologicalreleasehasbeeninitiated.Aradiologicalreleasehasbeenterminated.5.Asignificantchangeinplantconditionshasoccurred(e.g.,lossorrestorationofoff-sitepowerormajorplantequipment).Terminationoftheemergency.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:14of585.1StateandCountyNotification(continued)2.FormsRequiredforNotificationsCAUTIONNotificationsrequiretheuseofaformsimilartoAttachment1,FloridaNuclearPlantEmergencyNotificationForm.TheSupplementalDataSheetshallonlbetransmittedwithanewlcornletedSNF.A.Notificationswith15minutetimelimitsshallbemadeusingaformsimilartoAttachment1,FloridaNuclearPlantEmergencyNotificationForm.NOTETheSupplementalDataSheet(Attachment2)isNOTintendedforusebytheControlRoomandshouldNOTbepreparedbyortransmittedfromthatfacilit.B.AformsimilartotheSupplementalDataSheet(Attachment2)shouldalsobepreparedandtransmittedwiththeSNF.Itispermissibletoprepareandtransmitthe"PlantConditionsInformation"sectiononly,whendoseassessmentdataisunavailable.C.Notificationswith60minutetimelimitsshallbemadeusingaformsimilartoAttachment1,FloridaNuclearPlantEmergencyNotificationForm,andaformsimilartotheSupplementalDataSheet(Attachment2).Itispermissibletoprepareandtransmitthe"PlantConditionsInformation"sectiononly,whendoseassessmentdataisunavailable.3.Specialinstructionsduetoextraordinarycircumstances.A.IfEmergencyClassescalationisnecessaryduetorapidlydegradingconditionsandthetransmissionoftheSNFhasNOTbeeninitiated,Thenanewnotificationformshouldbefilled-outdescribingthelatestEmergencyClassandconditions,butalsoincludingreferencetotherapidescalationthroughthelowerclassification(e.g.,the"AdditionalInformationorUpdate"sectionoftheformshouldincludeastatementsimilarto"ReactorCoolantSystemleakagehadincreasedrapidlyanddidnotallowforseparatenotificationofanUnusualEvent").OR REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:15of585.1StateandCountyNotification(continued)3.A.(continued)2.thetransmissionofacompletelyfilled-outandapprovedSNFisunderway,ThenprovidetheStateandCountyauthoritieswiththeinitialnotificationinformationbytransmittinglines1-6,ataminimum,oftheSNFandterminatethephonecallbystatingthatanewnotificationformwillbeprovidedwithin15minutes.CAUTIONTherecannotbetwoconcurrentdeclaredemergencyclassesundertheSt.LuciePlantRadioloicalEmerencPlan.B.IfoneUnitisinaclassifiedeventandthesameortheotherUnitentersintoaneventwherethesameorlesserEmergencyClasswouldapply,ThenanewclassificationshouldNOTbedeclared.TheeventshouldbedocumentedonaSNFas"AdditionalInformationorUpdate"andissuedassoonaspracticable.C.IfoneUnitisinaclassifiedeventandtheotherUnitentersintoamoresevereeventinwhichahigherEmergencyClasswouldapply,Thenthenewclassificationshallbedeclaredandpromptly,withintheregulatorytimelimits,issuedtotheState,CountiesandtheNRC.4.g4TransferofNETControlA.TheStateCoordinatingOfficer(SCO)cantransferthecontrolofHotRingDown(HRD)NETfromtheStateWarningPoint(SWP)totheEOF.Whenthisoccurs;2.3.TheRMshalldofacetofacecommunicationtosatisfyoff-sitenotificationrequirementsfortheStateandCounties.CallstotheSWParenolongernecessary.TheFloridaNuclearPlantEmergencyNotificationForm(Attachment1)andtheSupplementalDataSheet(Attachment2)shallcontinuetobefilledout.CompletednotificationformsaretobeprovidedtotheSCOorhis/herdesigneeintheEOF.ENDOFSECTION5.1 REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:16of585.2NuclearRegulatoryCommission(NRC)Notification1.TimeLimitsNOTE~i~tifttNRCi*ptd~iditIfttifitifSI1andlocalagencies.Theone-hourtimelimitin10CFR50.72(a)(3)istoensuretimelyNRCnotificationincaseswherenotificationofStateandlocalaenciesisdelaedorroloned.A.ThelicenseeshallnotifytheNRCimmediatelyafternotificationoftheappropriateStateorlocalagenciesandnotlaterthanonehourafterthetimethelicenseedeclaresoneoftheEmergencyClasses(10CFR50.72(a)(3)).2.SpecialInstructionsA.InitialnotificationtotheNRCusingtheEmergencyNotificationSystem(ENS)(usuallydonefromtheControlRoom)shoulduseAttachment4,NRCReactorPlantEventNotificationWorksheet.B.C.D.E.AtanAlertorhigheremergencyclass,theNRCwillwanttoestablishanopenlineofcommunicationwiththeControlRoom,utilizinganENSconferencebridgetyinginthelicenseewithNRCHeadquartersandregionpersonnel.OncetheTechnicalSupportCenter(TSC)isoperational,theControlRoomshouldtransferresponsibilityforNRCcommunicationstotheTSC.TheEmergencyOperationsFacility(EOF)shouldjointheTSContheENSconferencebridgeandtaketheleadforNRCcommunications.TheTSCandEOFshouldalsoutilizetheHealthPhysicsNetwork(HPN)lineinamannersimilartotheENS(i.e.,establishaconferencebridgewiththeNRC).BoththeENSandHPNCommunicatorsinbothfacilitiesshouldkeeplogsofinformationtransmittedandreceivedfromtheNRCinaccordancewithprocedures.ENDOFSECTION5.2 REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:17of585.3giErroneousInformationIferroneousinformationistransmittedtooff-siteagenciesandtheerrorisdiscoveredpriortoeventtermination,acorrectionshouldbeprovidedinanupdate.Theneedforandurgencyofprovidingtheupdateisdependentupontheimportanceoftheerror.2.Iferroneousinformationistransmittedtooff-siteagenciesandtheerrorisdiscoveredaftereventtermination,theLicensingDepartmentshouldbeconsultedtodeterminetheneedandmethodforcontactingtheoff-siteagencieswithcorrectedinformation.ENDOFSECTION5.3 REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:18of58APPENDIXANOTIFICATIONSFROMTHEAFFECTEDCONTROLROOM(Page1of6)INITIALCAUTION~g~NotificationofStateandlocalagenciesshallbemadeassoonaspracticablewithin15minutesofdeclarationofanEmergencyClass.~$3AnewFloridaNuclearPlantEmergencyNotificationFormshallbecornletedforalludates.NOTEttg1.CompletionofthischecklistrequiresthefollowingAttachments(allfromEPIP-08):Attachment1-FloridaNuclearPlantEmergencyNotificationFormAttachment1A-DirectionsforCompletingtheFloridaNuclearPlantEmergencyNotificationFormAttachment3-DeterminationofProtectiveActionRecommendations(PARs)Attachment4-NRCReactorPlantEventNotificationWorksheetAttachment4A-DirectionsforCompletingtheNRCReactorPlantEventNotificationWorksheet2.ChecklistPart1isforStateWarningPointnotification.3.ChecklistPart2isforNRCnotification.1~StateWarningPointNotificationA.PreparetheFloridaNuclearPlantEmergencyNotificationForm(formsimilartoAttachment1)inaccordancewithAttachment1A,DirectionsforCompletingtheFloridaNuclearPlantEmergencyNotificationForm.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:19of58APPENDIXANOTIFICATIONSFROMTHEAFFECTEDCONTROLROOM(Page2of6)1.(continued)B.ObtaintheEmergencyCoordinator(EC)approval.INITIALNOTE1~PrimarynotificationmethodtotheStateWarningPoint(SWP)istousetheHotRingDown(HRD)phone.2.IftheHRDisout-of-service,alternatenotificationmethodsarerovidedinSectionE,below.C.D.UsingtheStateHOTRINGDOWN(HRD)Phone,dial100.Holddownthebuttononthehandsetwhiletalking.Thismustbedoneeachtimeyoutalk.Releasethebuttoninordertolisten.WhentheStateDutyOfficeranswers,announce"ThisisSt.LucieNuclearPlant[asapplicable(Unit1,2)]withanemergencymessage.IamstandingbytotransmitFloridaNuclearPlantEmergencyNotificationForminformationwhenyouarereadytocopy."AllowtheDutyOfficertocontactSt.LucieCounty,MartinCountyandtheBureauofRadiationControlpriortotransmittingtheinformationfromthenotificationform.Whenthepartiesareonline,providetheinformationslowly(e.g.,inthreewordintervals)anddeliberately,providingtimefortheinformationtobewrittendown.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:20of58APPENDIXANOTIFICATIONSFROMTHEAFFECTEDCONTROLROOM(Page3of6)1.(continued)E.AlternateNotificationMethods(inorderofpriority)INITIALNOTEUseofthecommercialtelephoneasanalternatenotificationmethodrequirescallbackverificationfromtheStateWarningPoint.UseofESATCOMorLocalGovernmentRadioasanalternatenotificationmethodshouldincludeacallbackverificationnumberifavailable(e.g.,cellularhone.1.Alternate1-CommercialPhonea.CalltheStateWarningPointusingthephonenumberintheSt.LuciePlantEmergencyResponseDirectory(ERD).Announce"ThisisSt.LucieNuclearPlant[asapplicable(Unit1/2)]withanemergencydeclaration.MycallbacknumberisC.Hangupthephoneandstandbyforthecallback.WhentheStateWarningPointgivesthego-ahead,providetheinformationfromtheFloridaNuclearPlantEmergencyNotificationForm.RequestcallbackfromtheStateWarningPointtoverifythattheynotifiedSt.LucieCounty,MartinCountyandtheBureauofRadiationControl.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:21of58APPENDIXANOTIFICATIONSFROMTHEAFFECTEDCONTROLROOM(Page4of6)1.E.(continued)2.Alternate2-ESATCOMINITIALNOTEUseESATCOMonlifAlternate1-commercialhoneisnotavailable.80C.d.Holddownthe"push-to-talk"buttononthehandsetandwait3-5secondstohearabeepbeforeyoustarttalking.Thismustbedoneeachtimeyoutalk.Announce"StateWarningPoint,thisisSt.LucieNuclearPlant[asapplicable(Unit1/2)]withanemergencydeclaration."Thenreleasethe"push-to-talk"buttoninordertolisten.WhentheStateWarningPointacknowledges,announce"StateWarningPoint,thisisSt.LucieNuclearPlant[asapplicable(Unit1/2)]declaringap1(Iif'tandingbytotransmitFloridaNuclearPlantEmergencyNotificationForminformationwhenyouarereadytocopy.WhentheStateWarningPointgivesthego-ahead,providetheinformationfromtheFloridaNuclearPlantEmergencyNotificationForm.Announce"St.Lucieclear"attheendoftheconversation.
REVISIONNO.:PROCEDURENo.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:22of58APPENDIXANOTIFICATIONSFROMTHEAFFECTEDCONTROLROOM(Page5of6)1.E.(continued)INITIALNOTEUseLocalGovernmentRadio(LGR)onlyifAlternate1andAlternate2arebothunavailable.LGRcommunicationscanbemadewithSt.LucieCountyandMartinCountyEmergencyOperationsCenters(EOCs)whowillrelaytotheStateWarninPointandtherelatotheBureauofRadiationControl.3.Alternate3-LocalGovernmentRadiob.C.d.e.Onchannel2,contactthecountyEOCsbyholdingdownthepush-to-talkbuttonandannouncing"St.LucieCountyEOC,thisisSt.LucieNuclearPlant[asapplicable(Unit1/2)]withanemergencydeclaration.Over."Thenreleasethe"push-to-talk"buttoninordertolisten.WhenSt.LucieCountyreplies,directthemtostandbywhileyoucontactMartinCounty.Whenbothcountiesareonline,announce"MartinandSt.LucieCountyEOCs,thisisSt.LucieNuclearPlant[asapplicable(Unit1/2)]declaringapstandingbytotransmitFloridaNuclearPlantEmergencyNotificationForminformationwhenyouarereadytocopy.Over."Whenthecountiesgivethego-ahead,providetheinformationfromtheFloridaNuclearPlantEmergencyNotificationForm.RequestSt.LucieCounty(iftheyareunable,MartinCounty)callbacktoverifythattheynotifiedtheStateWarningPointandtheBureauofRadiationControl.Endtheconversationbyannouncing"ThisisSt.LucieNuclearPlant[asapplicable(Unit1/2)],KNGR874,overandout."ENDOFPART1 REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:23of58APPENDIXANOTIFICATIONSFROMTHEAFFECTEDCONTROLROOM(Page6of6)INITIALCAUTIONNotificationoftheNRCisexpectedimmediatelyafternotificationofStateandlocalagencies.Theonehourtimelimitin10CFR50.72(a)(3)istoensuretimelyNRCnotificationincaseswherenotificationofStateandlocalaenciesisdelaedorroloned.2.NRCNotificationA.PreparetheNRCReactorPlantEventNotificationWorksheet(formsimilartoAttachment4)inaccordancewithAttachment4A,DirectionsforCompletingtheNRCReactorPlantEventNotificationWorksheet.B.ObtainECapproval.NOTE1.PrimarynotificationmethodtotheNRCistousetheEmergencyNotificationSystem(ENS)phone.2.IftheENSisout-of-serviceanalternatenotificationmethodisprovidedinSectionD,below.C.TransmittheformbydialingoneofthenumbersshownonthephoneorintheEmergencyResponseDirectory(ERD).D.AlternateNotificationMethod1~IftheENSisout-of-service,Thenuseacommercialphonetoaccomplishtheabove.ENDOFPART2ENDOFAPPENDIXA REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:24of58APPENDIXBNOTIFICATIONSFROMTHETECHNICALSUPPORTCENTERTSC(Page1of6)INITIALCAUTION~g~NotificationofStateandlocalagenciesshallbemadeassoonaspracticablewithin15minutesofdeclarationofanEmergencyClass.'tt3AnewFloridaNuclearPlantEmergencyNotificationFormshallbecornletedforalludates.NOTE~ChecklistPart1isfortheHRCCommunicator.~ChecklistPart2isfortheENSCommunicator.StateWarningPointNotificationA.PreparetheFloridaNuclearPlantEmergencyNotificationForm(formsimilartoAttachment1)inaccordancewithAttachment1A,DirectionsforCompletingtheFloridaNuclearPlantEmergencyNotificationForm.B.VerifytheEmergencyCoordinator(EC)approval.NOTE1.PrimarynotificationmethodtotheStateWarningPoint(SWP)istousetheHotRingDown(HRD)phone.2.IftheHRDisout-of-service,alternatenotificationmethodsarerovidedinSectionE,below.C.UsingtheStateHOTRINGDOWN(HRD)Phone,dial100.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:25of58APPENDIXBNOTIFICATIONSFROMTHETECHNICALSUPPORTCENTERTSC(Page2of6)(continued)INITIALD.E.Holddownthebuttononthehandsetwhiletalking.Thismustbedoneeachtimeyoutalk.Releasethebuttoninordertolisten.WhentheStateDutyOfficeranswers,announce"ThisisSt.LucieNuclearPlantTechnicalSupportCenterwithanemergencymessage.IamstandingbytotransmitFloridaNuclearPlantEmergencyNotificationFormandSupplementalDataSheetinformationwhenyouarereadytocopy."AllowtheDutyOfficertocontactSt.LucieCounty,MartinCountyandtheBureauofRadiationControlpriortotransmittingtheinformationfromthenotificationforms.Whenthepartiesareonline,providetheinformationslowly(e.g.,inthreewordintervals)anddeliberately,providingtimefortheinformationtobewrittendown.AlternateNotificationMethods(inorderofpriority)NOTEUseofthecommercialtelephoneasanalternatenotificationmethodrequirescallbackverificationfromtheStateWarningPoint.UseofESATCOMorLocalGovernmentRadioasanalternatenotificationmethodshouldincludeacallbackverificationnumberifavailable(e.g.,cellularhone.Alternate1-CommercialPhone80CalltheStateWarningPointusingthephonenumberintheSt.LuciePlantEmergencyResponseDirectory(ERD).Announce"ThisisSt.LucieNuclearPlantTechnicalSupportCenterwithanemergencydeclaration.MycallbacknumberisC.Hangupthephoneandstandbyforthecallback.WhentheStateWarningPointgivesthego-ahead,providetheinformationfromtheFloridaNuclearPlantEmergencyNotificationForm.RequestcallbackfromtheStateWarningPointtoverifythattheynotifiedSt.LucieCounty,MartinCountyandtheBureauofRadiationControl.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:26of58APPENDIXBNOTIFICATIONSFROMTHETECHNICALSUPPORTCENTERTSC(Page3of6)1.E.(continued)2.Alternate2-ESATCOMINITIALNOTEUseESATCOMonlifAlternate1-commercialhoneisnotavailable.80b.Holddownthe"push-to-talk"buttononthehandsetandwait3-5secondstohearabeepbeforeyoustarttalking.Thismustbedoneeachtimeyoutalk.Announce"StateWarningPoint,thisisSt.LucieNuclearPlantTechnicalSupportCenterwithanemergencydeclaration."Thenreleasethe"push-to-talk"buttoninordertolisten.C.d.WhentheStateWarningPointacknowledges,announce"StateWarningPoint,thisisSt.LucieNuclearPlantTechnicalSupportCenterdeclaringa/an(classification),repeat(classification).IamstandingbytotransmitFloridaNuclearPlantEmergencyNotificationForminformationwhenyouarereadytocopy.WhentheStateWarningPointgivesthego-ahead,providetheinformationfromtheFloridaNuclearPlantEmergencyNotificationForm.Announce"St.Lucieclear"attheendoftheconversation.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:27of58APPENDIXBNOTIFICATIONSFROMTHETECHNICALSUPPORTCENTERTSC(Page4of6)1..E.(continued)INITIALNOTEUseLocalGovernmentRadio(LGR)onlyifAlternate1andAlternate2arebothunavailable.LGRcommunicationscanbemadewithSt.LucieCountyandMartinCountyEmergencyOperationsCenters(EOCs)whowillrelaytotheStateWarninPointandtherelatotheBureauofRadiationControl.3.Alternate3-LocalGovernmentRadioC.d.Onchannel2,contactthecountyEOCsbyholdingdownthepush-to-talkbuttonandannouncing"St.LucieCountyEOC,thisisSt.LucieNuclearPlantTechnicalSupportCenterwithanemergencydeclaration.Over."Thenreleasethe"push-to-talk"buttoninordertolisten.WhenSt.LucieCountyreplies,directthemtostandbywhileyoucontactMartinCounty.Whenbothcountiesareonline,announce"MartinandSt.LucieCountyEOCs,thisisSt.LucieNuclearPlantTechnicalSupportCenterdeclaringaI(I~tiiipt(I~standingbytotransmitFloridaNuclearPlantEmergencyNotificationForminformationwhenyouarereadytocopy.Over."Whenthecountiesgivethego-ahead,providetheinformationfromtheFloridaNuclearPlantEmergencyNotificationForm.RequestSt.LucieCounty(iftheyareunable,MartinCounty)callbacktoverifythattheynotifiedtheStateWarningPointandtheBureauofRadiationControl.e.Endtheconversationbyannouncing"ThisisSt.LucieNuclearPlantTechnicalSupportCenter,KNGR874,overandout."ENDOFPART1 REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:28of58APPENDIXBNOTIFICATIONSFROMTHETECHNICALSUPPORTCENTERTSC(Page5of6)INITIALCAUTIONNotificationoftheNRCisexpectedimmediatelyafternotificationofStateandlocalagencies.Theone-hourtimelimitin10CFR50.72(a)(3)istoensuretimelyNRCnotificationincaseswherenotificationofStateandlocalaenciesisdelaedorroloned.2.NOTE1.PrimarynotificationmethodtotheNRCistousetheEmergencyNotificationSystem(ENS)phone.2.IftheENSisout-of-service,analternatenotificationmethodisrovidedinSectionB,below.NRCNotificationA.Chooseandcompletetheappropriatesteps,below:IftheNRCReactorPlantEventNotificationWorksheethasNOTpreviouslybeentransmittedfromtheControlRoom,ThenrequestthattheECAssistant/Logkeeperpreparetheform.2.3.4.VerifyECapproval.TransmittheformbydialingoneofthenumbersshownonthephoneorintheEmergencyResponseDirectory(ERD),thenGOTOthenextsteptoestablishanopenlineofcommunicationwiththeNRC.ORIftheNRCReactorPlantEventNotificationWorksheethaspreviouslybeentransmittedbytheControlRoom,TheninitiateanopenlineofcommunicationwiththeNRCbydialingoneofthenumbersshownonthephoneorintheERDandrequesttobeplacedontheConferenceBridgewiththeNRC.Asrequested,provideinformationtotheNRC.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:29of582.APPENDIXBNOTIFICATIONSFROMTHETECHNICALSUPPORTCENTERTSC(Page6of6)(continued)B.AlternateNotificationMethodIftheENSisout-of-service,Thenuseacommercialphonetoaccomplishtheabove.INITIALENDOFPART2ENDOFAPPENDIXB REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:30of58APPENDIXCNOTIFICATIONSFROMTHEEMERGENCYOPERATIONSFACILITYEOF(Page1of8)INITIALCAUTION~g~NotificationofStateandlocalagenciesshallbemadeassoonaspracticablewithin15minutesofdeclarationofEmergencyClassorchangeinProtectiveActionRecommendation(PAR).~g3AnewFloridaNuclearPlantEmergencyNotificationFormshallbecornletedforalludates.NOTE~ChecklistPart1isfortheHRDCommunicator.~ChecklistPart2isfortheENSCommunicator.StateWarningPointNotificationA.B.PreparetheFloridaNuclearPlantEmergencyNotificationForm(formsimilartoAttachment1)inaccordancewithAttachment1A,DirectionsforCompletingtheFloridaNuclearPlantEmergencyNotificationForm.VerifytheRecoveryManager(RM)approval.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:31of58APPENDIXCNOTIFICATIONSFROMTHEEMERGENCYOPERATIONSFACILITYEOF(Page2of8)1.(continued)INITIALNOTE1.PrimarynotificationmethodtotheStateWarningPoint(SWP)istousetheHotRingDown(HRD)phone.2.IftheHRDisout-of-service,alternatenotificationmethodsareprovidedinSectionD,below.3.StateandCountyrepresentativesmeansFloridaDivisionofEmergencyManagement(DEM),FloridaDepartmentofHealth(DOH),St.LucieCountyDepartmentofPublicSafety(DPS)andMartinCountyDepartmentofEmergencyServices(DES).4.NotificationformsmeanstheFloridaNuclearPlantEmergencyNotificationFormandtheSulementalDataSheet.C.Chooseandcompletetheappropriatestepbelow:IfStateandCountyrepresentativesareNOTco-locatedwiththeFPLEmergencyResponseOrganization(ERO)intheEOF,ThencalltheSWPandtransmitthenotificationforms.TocontacttheSWP,dial100.Holddownthebuttononthehandsetwhiletalking.Thismustbedoneeachtimeyoutalk.Releasethebuttoninordertolisten.WhentheStateDutyOfficeranswers,announce"thisisSt.LucieNuclearPlantEmergencyOperationsFacilitywithanemergencymessage.IamstandingbytotransmittheFloridaNuclearPlantEmergencyNotificationFormandtheSupplementalDataSheetinformationwhenyouarereadytocopy."AllowtheDutyOfficertocontacttheBureauofRadiationControl,St.LucieCountyDPSandMartinCountyDESpriortotransmittingtheinformationfromthenotificationforms.Whenthepartiesareonline,transmittheinformationslowly,(e.g.,inthreewordintervals)anddeliberately,providingtimefortheinformationtobewrittendown.OR REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:32of58APPENDIXCNOTIFICATIONSFROMTHEEMERGENCYOPERATIONSFACILITYEOF(Page3of8)C.(continued)INITIAL2.IfStateandCountyrepresentativesareco-locatedwiththeFPLEROintheEOFandtheStateCoordinatingOfficer(SCO)hasNOTassumedNetControl,ThencalltheSWPandtransmitthenotificationforms-"TimeofContact"correspondstothestarttimeoftheRecoveryManager'ProtectiveActionRecommendation(PAR)Briefing.TocontacttheSWP,dial100.Holddownthebuttononthehandsetwhiletalking.Thismustbedoneeachtimeyoutalk.Releasethebuttoninordertolisten.WhentheStateDutyOfficeranswers,announce"thisisSt.LucieNuclearPlantEmergencyOperationsFacilitywithanemergencymessage.IamstandingbytotransmittheFloridaNuclearPlantEmergencyNotificationFormandtheSupplementalDataSheetinformationwhenyouarereadytocopy."AllowtheDutyOfficertocontacttheBureauofRadiationControl,St.LucieCountyDPSandMartinCountyDESpriortotransmittingtheinformationfromthenotificationforms.Whenthepartiesareonline,transmittheinformationslowly,(e.g.,inthreewordintervals)anddeliberately,providingtimefortheinformationtobewrittendown.ORIfStateandCountyrepresentativesareco-locatedwiththeFPLEROintheEOFandtheSCOhastransferredNetControltotheEOF,ThentheSWPisnotcalled(completednotificationformsaregiventotheSCO-maybeaccomplishedbytheRMorRMOPSAdvisor/Logkeeper).
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:33of58APPENDIXCNOTIFICATIONSFROMTHEEMERGENCYOPERATIONSFACILITYEOF(Page4of8)1.(continued)D.AlternateNotificationMethods(inorderofpriority)INITIALNOTEUseofthecommercialtelephoneasanalternatenotificationmethodrequirescallbackverificationfromtheStateWarningPoint.UseofESATCOMorLocalGovernmentRadioasanalternatenotificationmethodshouldincludeacallbackverificationnumberifavailable(e.g.,cellularhone.1~Alternate1-CommercialPhone80CalltheStateWarningPointusingthephonenumberintheSt.LuciePlantEmergencyResponseDirectory(ERD).Announce"ThisisSt.LucieNuclearPlantEmergencyOperationsFacilitywithanemergencydeclaration.Mycallbacknumberisb.C.Hangupthephoneandstandbyforthecallback.WhentheStateWarningPointgivesthego-ahead,providetheinformationfromtheFloridaNuclearPlantEmergencyNotificationForm.RequestcallbackfromtheStateWarningPointtoverifythattheynotifiedSt.LucieCounty,MartinCountyandtheBureauofRadiationControl.
REVISIONNO.:PROCEDURENo.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:34of58APPENDIXCNOTIFICATIONSFROMTHEEMERGENCYOPERATIONSFACILITYEOF(Page5of8)1.D.(continued)2.Alternate2-ESATCOMINITIALNOTEUseESATCOMonlifAlternate1-commercialhoneisnotavailable.aiC.Holddownthe"push-to-talk"buttononthehandsetandwait3-5secondstohearabeepbeforeyoustarttalking.Thismustbedoneeachtimeyoutalk.Announce"StateWarningPoint,thisisSt.LucieNuclearPlantEmergencyOperationsFacilitywithanemergencydeclaration."Thenreleasethe"push-to-talk"buttoninordertolisten.WhentheStateWarningPointacknowledges,announce"StateWarningPoint,thisisSt.LucieNuclearPlantEmergencyOperationsFacilitydIigI(~I~1)pt(l~IamstandingbytotransmitFloridaNuclearPlantEmergencyNotificationForminformationwhenyouarereadytocopy."WhentheStateWarningPointgivesthego-ahead,providetheinformationfromtheFloridaNuclearPlantEmergencyNotificationForm.Announce"St.Lucieclear"attheendoftheconversation.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:35of58APPENDIXCNOTIFICATIONSFROMTHEEMERGENCYOPERATIONSFACILITYEOF(Page6of8)1.D.(continued)INITIALNOTEUseLocalGovernmentRadio(LGR)onlyifAlternate1andAlternate2arebothunavailable.LGRcommunicationscanbemadewithSt.LucieCountyandMartinCountyEmergencyOperationsCenters(EOCs)whowillrelaytotheStateWarninPointandtherelatotheBureauofRadiationControl.3.Alternate3-LocalGovernmentRadioa.C.d.e.Onchannel2,contactthecountyEOCsbyholdingdownthepush-to-talkbuttonandannouncing"St.LucieCountyEOC,thisisSt.LucieNuclearPlantEmergencyOperationsFacilitywithanemergencydeclaration.Over."Thenreleasethe"push-to-talk"buttoninordertolisten.WhenSt.LucieCountyreplies,directthemtostandbywhileyoucontactMartinCounty.Whenbothcountiesareonline,announce"MartinandSt.LucieCountyEOCs,thisisSt.LucieNuclearPlantEmergencyOperationsFacilitydIg/(Ifi.p~ti).I1digtyttitFIidNuclearPlantEmergencyNotificationForminformationwhenyouarereadytocopy.Over."Whenthecountiesgivethego-ahead,providetheinformationfromtheFloridaNuclearPlantEmergencyNotificationForm.RequestSt.LucieCounty(iftheyareunable,MartinCounty)callbacktoverifythattheynotifiedtheStateWarningPointandtheBureauofRadiationControl.Endtheconversationbyannouncing"ThisisSt.LucieNuclearPlantEmergencyOperationsFacility,KNGR874,overandout."ENDOFPART1 REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:36of58APPENDIXCNOTIFICATIONSFROMTHEEMERGENCYOPERATIONSFACILITYEOF(Page7of8)INITIALCAUTIONNotificationoftheNRCisexpectedimmediatelyafternotificationofStateandlocalagencies.Theone-hourtimelimitin10CFR50.72(a)(3)istoensuretimelyNRCnotificationincaseswherenotificationofStateandlocalaenciesisdelaedorroloned.2.g~NRCNotificationNOTE1.PrimarynotificationmethodtotheNRCistousetheEmergencyNotificationSystem(ENS)phone.2.IftheENSisout-of-service,analternatenotificationmethodisrovidedinSectionB,below.A.Chooseandcompletetheappropriatesteps,below:IftheNRCReactorPlantEventNotificationWorksheethasNOTpreviouslybeentransmittedfromeithertheControlRoomorTechnicalSupportCenter(TSC),ThenrequestthattheRMOPSAdvisorpreparetheform.2.4.5.VerifyRMapproval.TransmittheformbydialingoneofthenumbersshownonthephoneorintheEmergencyResponseDirectory(ERD),thenGOTOthenextsteptoestablishanopenlineofcommunicationwiththeNRC.ORIftheNRCReactorPlantEventNotificationWorksheethaspreviouslybeentransmittedbyeithertheControlRoomortheTSC,TheninitiateanopenlineofcommunicationwiththeNRCbydialingoneofthenumbersshownonthephoneorintheERDandrequesttobeplacedontheConferenceBridgewiththeNRCandtheSt.LucieTSC.TaketheleadinprovidinginformationtotheNRC.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:37of58APPENDIXCNOTIFICATIONSFROMTHEEMERGENCYOPERATIONSFACILITYEOF(Page8of8)2.(continued)B.AlternateNotificationMethod1.IftheENSisout-of-service,Thenuseacommercialphonetoaccomplishtheabove.INITIALENDOFPART2ENDOFAPPENDIXC REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:38of58ATTACHMENT1FLORIDANUCLEARPLANTEMERGENCYNOTIFICATIONFORM(Page1of1)1.A.0THISISADRILLB.0THISISANACTUALEVENT2.A.Time/DatecontactmadeC.MessageNumber3.Site:A.0CrystalRiverUnit3D.0TurkeyPointUnit3B.Reportedby:(Name/Title)D.Reportedfrom:0ControlRoom0TSC0EOFB.0St.LucieUnit1C.0St.LuciaUnit2E.OTurkeyPointUnit44.AccidentClassificationA.0NotificationofUnusualEventC.0SiteAreaEmergencyB.0AlertD.0GeneralEmergency5.CurrentEmerenDeclaration:6.ReasonforEmerencDeclarationTime:Date:7.AdditionalInformationorUdate:A.WinddirectionfromdegreesB.DownwindSectorsAffected(minimumof3):10.ReleaseStatus:A.0NoRelease(GotoItem12)C.0AReleaseoccurred,butstoppedB.0AReleaseisoccurring11.OffsiteReleaseSinificanceCateoattheSiteBoundaA.0Informationnotavailableatthistime.B.0Releasewithinnormaloperatinglimits(63.5E-1ci/secnoblegas,54.6E-5ci/seciodine)C.0Non-SignificantFractionofPAGRange(releaseis)normallimitsand(500mRTEDEand1000mRCDE)D.0PAGRange(2500mRTEDEor21000mRCDE)9.WeatherData8.InuriesReuirinOffsiteSuort:A.QNoOYesOUnknownB.Contaminated:0NoOYesOUnknown12.UtiliRecommendedProtectiveActions:A.0NoneB.0ShelterZones/Areas:EvacuateZones/Areas:ORC.0MilesNoActionSectorsEvacuateSectors0-22-55-10ShelterSectors13.HasEventBeenTerminated?:A.ONo14.SulementalFormisAttached?:A.0NoB.0Yes:B.0Yes:Time:Date:ECorRMApprovalSignature:15.MessaeReceivedB:Name:Time:Time:Date:Date:IfemergencycIassescalationisknowntobenecessaryandanewnotificationformwillbetransmittedwithin15minutes,thenyoumaygotoline15.PSL-F070ENDOFATTACHMENT1EffectiveDate:05/31/00 REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:39of58g6ATTACHMENT1ADIRECTIONSFORCOMPLETINGTHEFLORIDANUCLEARPLANTEMERGENCYNOTIFICATIONFORM(Page1of6)ITEMENTRY2A.2B.Checkappropriateboxfordrilloractualemergencyasthecasemaybe.Duringexercises,drills,ortests,eachmessageshallbecheckedTHISISADRILL.Enterthetime(usingtheofficialtime,normallysynchronizedwithERDADS)whencontactismadewiththeStateWarningPointorthestarttimeoftheRMPARBriefing.Forinitialnotificationofclassification,thisshallbewithin15minutesofthe"CurrentEmergencyDeclaration"timeinitem5.Enterthenameandtitleofpersonmakingthenotificationcall(e.g.,JohnDoe,DutyCallSupervisor).2C.2D.Enterthemessagenumberbeginningwith¹1andfollowingsequentiallyinallfacilities(e.g.,iftheControlRoomtransmittedtwomessagestheTSCwouldstartwith¹3).Checktheboxforthefacilityfromwhichthenotificationisbeingmade.SiteChecktheboxfortheappropriateplantsitefortheemergencydeclaration(bothStLucieboxesmightneedtobecheckedfordualuniteventssuchasapproachofahurricane).AccidentClassificationChecktheboxcorrespondingtocurrentaccidentclassificationdeclaredbytheEC.CurrentEmerencDeclarationEntertheemergencydeclarationtimeanddate(asdeterminedbytheEC)forthecurrentaccidentclassification.ReasonforEmerencDeclarationEnterwordinglikethatfoundintheEmergencyActionLevel(EAL)informationinEPIP-01,ClassificationOfEmergencies.Wordingshouldbebriefyetdescriptiveenoughfortheoff-siteagenciestogainanunderstandingoftheevent.ItshouldbeclearfromtheincidentdescriptionwhichEALhasnecessitatedtheemergencydeclaration.Wordingshouldbeasnon-technicalaspossiblewithnoacronymsorabbreviations.Thisinformationshouldremainthesamethroughoutupdatemessages,unlessthereisaclassificationchange.(TheEChasthisinformation.)
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSAIVDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:40of58ATTACHMENT1ADIRECTIONSFORCOMPLETINGTHEFLORIDANUCLEARPLANTEMERGENCYNOTIFICATIONFORM(Page2of6)7.AdditionalInformationorUdateEnteradditionalinformation,ifnecessary,orreasonforupdatehere.Forexample:ProtectiveActionRecommendations(PARs)change~Anoccurrencethatwouldotherwiseresultinaloweremergencyclassification,onotherunit~WeatherchangesaffectingpublicsafetyRadiationlevelchanges~Lossofoff-sitepower,etc.In'uriesReuirinOff-siteSuortMOTEKeepcheckingthesameboxes,initem8,onsubsequentnotificationsunlessafirstinjuryoccurs,statusofcontaminationbecomesknownorerroneousdataisbeingcorrected.ThecheckedboxistoalerttheCountythatpatienttransportisinvolvedintheemergency.Thatfactdoesnotchangeeventhoughthetransportmayhavealreadyoccurredduringareviousnotification.A.Checktheappropriatebox.Checkboxfor"Yes"onlyifaninjuryoccursthatinvolvesoff-sitesupport(EMS,hospital).Check"Unknown"iftheextentoftheinjuryisunknownatthistimeorifitisnotyetknownifoff-sitetreatmentisnecessary.B.Checktheappropriatebox.Checkboxfor"Unknown"onlyifthenatureoftheinjuryhaspreventedthoroughmonitoringon-siteorifthereisanydoubtwhethercontaminationispresent.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:41of58ATTACHMENT1ADIRECTIONSFORCOMPLETINGTHEFLORIDANUCLEARPLANTEMERGENCYNOTIFICATIONFORM(Page3of6)NOTEIftheClassAModel(doseprojectionmodel)isbeingused,a'StateNotificationFormSummarySheet'savailablewhichprovidesinformationforcompletionofitems9-12.TheinformationisinaformatsimilartothatfoundontheFloridaNuclearPlantEmerencNotificationForm.9.WeatherDataNOTE10meterdatashouldbeused.A.ttq0WinddirectioncanbeobtainedfromERDADSbydepressingthe"EPIP"key,onthetoprowofthekeyboard.TheMetTowerIndicatorPanelintheUnit1ControlRoomisanalternatesource.Ifthesetwosourcesarenotavailable,refertoAttachment1,MeteorologicalData,inEPIP-09,Off-SiteDoseCalculations.B.Ifthewinddirectionisgreaterthan360'hewinddirectionisdeterminedbysubtracting360'romtheindicatednumber.Winddirectionshouldberoundedtothenearestwholenumber.C.Winddirectionisalwaysgivenas"windfrom"(aneasterlywind,orwinddirection90',meansthatthewindisblowingfromeasttowest).D.Whendeterminingthesectorsaffected,theadjacentsectorsonbothsidesoftheactualdownwindsectorareincluded.Threesectorswilltypicallybelisted.E.Ifthewindislocatedontheedgeofasector(i.e.,11',33',etc.)andadditional(fourth)sectorshouldbeadded.F.Enterthewinddirection(windfrom)indegreesinitem"A."
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:42of58ATTACHMENT1ADIRECTIONSFORCOMPLETINGTHEFLORIDANUCLEARPLANTEMERGENCYNOTIFICATIONFORM(Page4of6)9.(continued)G.Enterthedownwindsectorsinitem"B."WindFromSectorsAffectedWindFromSectorsAffectedWindFromSectorsAffected348-11HJK123-146PQR11-33JKL146-168QRA33-56KLM168-191RAB56-78LMN191-213ABC78-101IVINP213-236BCD101-123NPQThereisno"0"sector10.ReleaseStatus236-258CDE258-281DEF281-303EFG303-326FGH326-348GHJThereisno"I"sectorA.Iftherearenoindicationsofareleaseofradioactivematerial,checkbox"A"andgotoitem12.Areleaseofradioactivematerial(duringanydeclaredemergency)isdefinedas:~Anyeffluentmonitorincreaseof(approximately)10timesoronedecadeabovepre-transientvaluesOR~HealthPhysicsdetectingairborneradioactivitylevelsinexcessof25%derivedairconcentration(DAC)outsideofplantbuildingsduetofailureofequipmentassociatedwiththedeclaredemergency.B.Ifareleaseofradioactivematerialisoccurring,eventhoughitmaybelessthannormaloperatinglimits,checkbox"B."Ifareleasehasoccurredbutstopped,checkbox"C."SpecificdoseinformationshouldbesuppliedonthesupplementaldatasheetaftertheTSCisdeclaredoperationalatanAlertorhigherclassification.DoseAssessmentpersonnelintheTSCorEOFwillhavethisinformation.TheTSCChemistrySupervisor,TSCHPSupervisororEOFHPManagershouldbecontactedforthedata.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:43of58ATTACHMENT1ADIRECTIONSFORCOMPLETINGTHEFLORIDANUCLEARPLANTEMERGENCYNOTIFICATIONFORM(Page5of6)11.OffsiteReleaseSinificanceCateoDoNotCheckAnyBoxinItem11ifyouCheckedBox10"A"NoReleaseA.Ifareleaseisoccurringorhasoccurredanddoseinformationisnotavailableatthetimeofnotification,checkbox"A"andfollowupassoonasinformationbecomesavailable.B.Checkbox"B"ifbothnoblegasandiodinereleaseratesarelessthanorequaltothefollowing:NobleGasrelease<3.5E+5pci/sec(3.5E-1Ci/sec)Iodinerelease<4.6E+1pci/sec(4.6E-5Ci/sec)C.Checkbox"C"ifeithernoblegasoriodinereleaseratesexceedthevaluesin"B"(above)butforecasted1miledosesarelessthaneither500mremTEDEor1000mremThyroidCDE.Thesedosesarelessthanthestate'sProtectiveActionGuide(PAG)levels.D.Checkbox"D"ifforecasted1miledosesaregreaterthanorequaltoeither500mremTEDEor1000mremThyroidCDE.ThesePAGlevelsrequirestateandcountyaction.12.UtilitRecommendedProtectiveActionsA.Iftherearenoprotectiveactionrecommendations(PARs),checkBox"A."B.ThisboxpertainstoCrystalRiverormaybeusedbyoff-siteagenciesandshouldnotbeusedbyFPL.C.IfPARsarenecessary,thencheckBox"C."DetermineappropriatePARsusingtheguidanceinAttachment3tothisprocedure.CopythePARsintoitem12"C."IndicatePARsusingonlythewordsNONE,ALL,ALLREMAININGorbylistingthelettersofthesectorsaffected.ProtectiveActionRecommendationsshallbeapprovedbytheEmergencyCoordinator(EC)ortheRecoveryManager(RM).
REVISIONNO.:PROCEDURENo.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:44of58ATTACHMENT1ADIRECTIONSFORCOMPLETINGTHEFLORIDANUCLEARPLANTEMERGENCYNOTIFICATIONFORM(Page6of6)13.HasEventBeenTerminated?A.Checkbox"A"iftheeventhasnotbeenterminated.DONOTENTERATIMEORDATE.B.Checkbox"B"iftheeventhasbeenterminatedandenterthetimeanddateoftermination.TheEChasthisinformation.14.SulementalFormIsAttached?NOTETheSulementalDataSheetisNOTforuseintheControlRoom.A.Checkbox"A"unlessaSupplementalDataSheethasbeencompletedforthisparticularmessage.B.Checkbox"B"ifaSupplementalDataSheetisaccompanyingthismessage.TheEmergencyCoordinator(EC)orRecoveryManager(RM)shallsigntoindicateapprovaltotransmittheinformationcontainedontheformunlessthesecondpage(SupplementalDataSheet)issignedforatwo-pagenotification.TheECorRMApprovalSignaturelineisnotnumberedbecausethestateandcountiesdonotneedthisinformation.DONOTATTEMPTTOTRANSMITTHISINFORMATIONVIAHOTRINGDOWN.Thestateandcountyforms,towhichtheyarecopyingdata,donotcontainthissignatureline.15.MessaeReceivedBEnterthenameoftheStateWarningPointDutyOfficerortheindividualthatreceivesthenotification.EnterthetimeattheStateWarningPoint(requestitfromtheDutyOfficer)andindicatethedatethecalliscompleted.ENDOFATTACHMENT1A REVISIONNO.:3PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:45of58ATTACHMENT2SUPPLEMENTALDATASHEET(Page1of1)ThefollowingsupplementaldataistobecompletedaftertheTSCorEOFisdeclaredoperationalatAlertorhigher.SupplementtoMessageNumberPLANTCONDITIONSINFORMATIONCriticalSafetFunctions:A.ReactorShutdown?0YesB.CoreAdequatelyCooled?0YesC.AdequateEmergencyPowerAvailable(Diesels)70YesFissionProductBarrierStatus:(Checkoneconditionforeachbarrier)0No0No0NoBARRIERFuelCladdingPri.ReactorCoolantSystemContainmentINTACTNoIndicationofcladdamageLeakageiswithinnormalchargingormakeuppumpcaacitNoevidenceofcontainmentleakageortuberupturereleaseisonlythrouhcondenserCHALLENGEDCladIsintactbutlosingsubcooling,waterlovel,etc.LeakageIswithinsafetyinjectioncapacityNoleakagebutcontainmentpressureisatorabovosafetysystemactuationpointsLOSTCladhasfailed,indicatedbyhightemps.,highcontainmentrad,etc.LeakageexceedssafetyinjectioncapacityEvidenceofcontainmentleakage(knownreleasepathorradsurveys)REGAINEDCoolingrestored,nofurtherdegradationexectedLeakagereducedtowithininjectioncapacity(systemrepaired)RepaireffortshaveisolatedleakorcontainmentpressurehasreducedtostopleakaeCompletedby:Time:Date:2.ReleaseRate:A.0NobleGases:CuriespersecondB.0lodines:CuriespersecondA.0AirborneTime/DateStarted:Time/DateStopped:4.Pro'ectedOff-SiteDoseRate:DistanceThroidDoseRateCDE1Mile(SiteBoundary)A.mrem/hr2MilesC.mrem/hr5MilesE.mrem/hr10MilesG.mrem/hr5.WeatherDatausedfortheabovedata:A.WindDirectionfromdegreesB.WindSpeedMPHC.StabilityClass0Measured0Default0Measured0DefaultB.0LiquidTime/DateStarted:Time/DateStopped:TotalDoseRateTEDEmrem/hrmrem/hrmrem/hrmrem/hrB.D.F.RADIOLOGICALDOSEASSESSMENTDATA1.ReleaseStatus:A.0NoRelease(nofurtherdatarequired)C.0AReleaseoccurred,butstoppedB.0AReleaseisoccurringCompletedBy:EmergencyCoordinatororRecoveryManagerApprovalPSL-F071Time:Date:Effective:05/31/00ENDOFATTACHMENT2 REVISIONNO.:PROCEDURENo.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:46of58ATTACHMENT2ADIRECTIONSFORCOMPLETINGTHESUPPLEMENTALDATASHEET(Page1of4)"SupplementtoMessageNumber"isthesamenumberrecordedin2."C"ontheFloridaNuclearPlantEmergencyNotificationFormassociatedwiththisSupplementalDataSheet.PlantConditionsInformationCriticalSafetFunctionsAnswerthethreequestions"yes"or"no"bycheckingtheappropriatebox.A.Isthereactorshutdown?B.Isthecoreadequatelycooled?C.Isthereadequateemergencypoweravailable(diesels)?FissionProductBarrierStatusCheckoneconditionforeachbarrier-intact,challenged,lost,orregained."CompletedBy"shouldbefilledinbythepersonrecordingtheinformationonthisformbyprintingtheirnameonthisline.RadioloicalDoseAssessmentData(ToBeObtainedfromDoseAssessmentPersonnel)NOTEIftheClassAModelisbeingused,a'SupplementalDataSheet-RadiologicalDoseAssessmentData'ormisavailablewhichprovidesinformationforcompletionofitems1-5.TheinformationisinaformatsimilartothatfoundontheSulementalDataSheet.ReleaseStatusA.Iftherearenoindicationsofareleaseofradioactivematerial,checkbox"A."B.Ifareleaseofradioactivematerialisoccurring,eventhoughitmaybelessthannormaloperatinglimits,checkbox"B."C.Ifareleaseofradioactivematerialhasoccurredbutstopped,checkbox"C."
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:47of58ATTACHMENT2ADIRECTIONSFORCOMPLETINGTHESUPPLEMENTALDATASHEET(Page2of4)1.ReleaseStatus(continued)Areleaseofradioactivematerial(duringanydeclaredemergency)isdefinedas:~Anyeffluentmonitorincreaseof(approximately)10timesoronedecadeabovepre-transientvaluesORHealthPhysicsdetectingairborneradioactivitylevelsinexcessof25%derivedairconcentration(DAC)outsideofplantbuildingsduetofailureofequipmentassociatedwiththedeclaredemergency.2.ReleaseRateThissectionrequiresthecompletedresultsofdoseassessment.A.Checkthenoblegasboxforanoblegasrelease.Writethereleaserate(incuriespersecond)inthespaceprovided.Checkeither"Measured"or"Default"toindicatehowthereleaseratewasdetermined.B.Checktheiodinesboxforaniodinerelease.Writethereleaserate(incuriespersecond)inthespaceprovided.Checkeither"Measured"or"Default"toindicatehowthereleaseratewasdetermined.3.T~TRICheckthetypeofrelease-eitherairborneorliquid.Enterthetimeanddatethatthereleasestartedandstopped.4.Pro'ectedOff-SiteDoseRateThissectionrequiresthecompletedresultsofdoseassessment.EntertheprojectedThyroidDoseRate(CDE)andtheTotalDoseRate(TEDE)inmrem/hrforthesiteboundary,2,5,and10miledistances.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:48of58ATTACHMENT2ADIRECTIONSFORCOMPLETINGTHESUPPLEMENTALDATASHEET(Page3of4)5.WeatherDataNOTE10meterdatashouldbeused.A.QqaTemperature,windspeedandwinddirectioncanbeobtainedfromERDADSbydepressingthe"EPIP"key,onthetoprowofthekeyboard.TheMetTowerIndicatorPanelintheUnit1ControlRoomisanalternatesource.Ifthesetwosourcesarenotavailable,referto'Attachment1,MeteorologicalData,inEPIP-09,Off-siteDoseCalculations.B.Ifthewinddirectionisgreaterthan360'hewinddirectionisdeterminedbysubtracting360'romtheindicatednumber.Winddirectionshouldberoundedtothenearestwholenumber.C.Winddirectionisalwaysgivenas"windfrom"(aneasterlywind,orwinddirection90',meansthatthewindisblowingfromeasttowest).D.Enterthewinddirection(windfrom)indegreesinitem"A".E.EnterthewindspeedinMilesPerHour(MPH)initem"B".F.StabilityClass-EnterthestabilityclassasdeterminedbyusingtheFigurebelow.Tofindthestabilityclass,determinedeltaT(temperature)bysubtractingthelowertemperaturereadingfromtheuppertemperaturereading.
REVISIONNO.:PROCEDURENo.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:49of58ATTACHMENT2ADIRECTIONSFORCOMPLETINGTHESUPPLEMENTALDATASHEET(Page4of4)5.(continued)IfDelta-TisIslessthanoreualto-1.7-1.6To-1.5-1.4-1.3To-0.5-0.4To+1.4+1.5To+3.6reaterthan+3.6ThenStabilitClassisCDGCompletingtheSupplementalDataSheetCompletedBy:Thepersoncompletingtheformshouldprinttheirnameonthisline.ApprovalneedstobesignedbytheECorRMwhoapprovestheforms.TheECorRMshallsigntoindicateapprovaltotransmittheinformationcontainedontheforms.TheSupplementalDataSheetsignature,foratwo-pagenotification,indicatesapprovalofboththefirstandsecondpages.Onatwo-pagenotificationtheECorRMonlyneedsignthesecondpagetoapproveboththeFloridaNuclearPlantEmergencyNotificationFormandtheSupplementalDataSheet.The"EmergencyCoordinatororRecoveryManagerApproval"linesarenotnumberedbecausethestateandcountiesdonotneedthisinformation.DONOTATTEMPTTOTRANSMITTHISINFORMATIONVIAHOTRINGDOWN.Thestateandcountyforms,towhichtheyarecopyingdata,donotcontaintheselines.ENDOFATTACHMENT2A REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:50of58ATTACHMENT3DETERMINATIONOFPROTECTIVEACTIONRECOMMENDATIONSPARs(Page1of5)NOTEInitialnotificationfromtheControlRoommayutilizePARsbasedonplantconditions.Oncedoseassessmentbegins,PARsshouldbemadeutilizingallavailabledataincludingoff-sitedoseprojections,plantconditionsandfieldmonitoringdata.Bothplantconditionsandoff-sitedosesshallbeconsidredforPARs.Themostconservativerecommendationsshouldbemade.IfitisanticipatedthatathresholdforaPARwillbeexceeded,itisneithernecessarynordesirabletowaituntilthethresholdisexceededtomakethatPAR.PARFlowchartA.PARsBasedonPlantConditions2.3.4.BeginintheupperlefthandcornerofthechartbyansweringtheGeneralEmergency(GE)question.CorrectlyanswerthequestionsuntilyoureachoneoftheboxesthatprovidesPARinformationbasedonplantconditions.Ifthereisnorelease,ThengotothePARWorksheetandfill-inthePARsbasedonplantconditions.Thesectorsaffectedcanbedeterminedbyreferringtonumber9,WeatherData,inAttachment1A,DirectionsforCompletingtheFloridaNuclearPlantEmergencyNotificationForm.Ifareleaseisinvolved,ThengotoSectionB,PARsBasedonOff-siteDose,below.
REVISIONNO.:PROCEDURENo.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:51of58ATTACHMENT3DETERMINATIONOFPROTECTIVEACTIONRECOMMENDATIONSPARs(Page2of5)1.(continued)NOTE~IftheClassAModelprintout,StateNotificationFormSummarySheetisavailable,itshouldbeusedtocomparedose-basedPARsagainstPARsbasedonplantconditions.~Calculatedoff-sitedosesshouldbecomparedtofieldmonitoringdatawhendetermininPARs.PARsBasedonOff-siteDosePARsarebasedontheTotalEffectiveDoseEquivalent(TEDEortotaldose)and/ortheCommittedDoseEquivalent(CDE,thyroiddose).DoNOTusedoseratevalues.2.3.IfusingtheClassAModel,TheninForecastMode,printtheStateNotificationFormSummaryforcomputergeneratedPARs.a.GotoSectionC,PARWorksheetIfusingEPIP-09,Off-siteDoseCalculations,ThencalculateTEDEandCDEinaccordancewiththeprocedure.80b.C.ComparetheTEDEdoseat1milewiththevaluesontheFlowchart.Enterthechartattheappropriatedoselevelbydeterminingifthedoseisbetween500and999mremorbetween1000and4999mremor5000mremorgreater.Fromtheselecteddoselevel,movetotherightonthecharttothefirstcolumn,0-2miles.ThePARprovidedcorrespondstothecalculatedTEDEat1mile.EnterthePARinthe0-2milesblockontheTEDEDOSEtablebelowthePARFlowchart.Thesectorsaffectedcanbedeterminedbyreferringtonumber9,WeatherData,inAttachment1A,DirectionsforCompletingtheFloridaNuclearPlantEmergencyNotificationForm.
REVISIONNO.:PROCEDURENo.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:52of58ATTACHMENT3DETERMINATIONOFPROTECTIVEACTIONRECOMMENDATIONSPARs(Page3of5)3.(continued)ContinuetodeterminethecorrespondingPARat2-5milesusingthecalculated2mileTEDE,at5-10milesusingthecalculated5mileTEDEandthe10milesplus(ToBeDetermined(TBD)distance)usingthecalculated10mileTEDE,asnecessary.e.EnterthePARinformationintheappropriateblocksoftheTEDEDOSEtable.FollowthesamemethodologyfordeterminingthePARscorrespondingtothecalculatedCDEvaluesbeginningwiththecalculatedvalueat1mile.C.g.EntereachofthedeterminedPARsintheCDE(Thyroid)DOSEtablebelowthePARFlowchart.h.GotoSectionC,PARWorksheet.PARWorksheetFill-inthetime/dateandemergencyclass.2.3.4.5.InPartA,determinethemostconservativePARsbycomparingthePARsbasedonplantconditionsagainstthosebasedonoff-sitedose.ItisimportanttocomparePARsateachdistance(0-2,2-5,5-10)becausethebasisofthemostconservativePARcouldbedifferentatdifferentdistances.EnterthemostconservativePARsintothetableinPartB,ProtectiveActionsRecommendedbyFPL.Usetheword(s)NONE,ALL,ALLREMAININGorlisttheindividualaffectedsectorsbyletter.Obtainreviewandapproval.TransfertheapprovedPARstotheFloridaNuclearPlantEmergencyNotificationForm.
REVISIONNO.:3PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:53of58ATTACHMENT3DETERMINATIONOFPROTECTIVEACTIONRECOMMENDATIONSPARs(Page4of5)GeneralEmergency'ontinueToAssessConditionsYatIMILESNOACTIONEVACUATESHELTERActtfalorProlectedLossofPhysical0.2gonegonesevereCoreDama9eyControlofPlanty2-5AllRemaininggoneISectorsAffectedI510AIINoneNoneMILESNOACTIONEVACUATESHELTER0-2NoneAllNone2-5None(SectorsAffectedAIIRemaining5-10NoneNoneAllffctaat.SeverecoredamageIstndcstadby.~lossofcntcatfuncoonarequiredibrcoreprotecton(e9.toesoflnjacdonvvdhlocA)oR~ffchcoretemperstunya(vsrsfcEYfyestarthanTN'F)QR~CHRRMresort)greaterthan4.2EaRrhr.2.LossofphysicalconsolofcontrolRoomorvttstreaderoperettasareastoattnrders.PARsBasedonOff-SiteDose(Forusewithmanualdosecalculationonly.NottobecompletedwhenClassAModelisused)TEDEDOSETGOE500*-999mromCDE(Thyroid)02MilosDUse1milevalueCDE1000'M999~ShelterAllmrom25MilosUse2milovaluoSheller(SoctorsAffected)Beyondtomaesuseml~ColumnandInetomseDoseValue5-10MnosUso5mllevaluoShoiter(SoctorsAffectod)DosebelowuvelewlreovbesNOACTIONTEDE1000&999mrornDCDG5000-24999~EvacuateAllmromEvacuato(SoctorsAffoctod)eSholtorAllRomainingEvacuate(SectorsAffected)ShelterAllRemainingOTGDGCOEGreaterGreaterTEDEDOSEEvacuate(SectorsAffoctod)GvacuotoAll+ShelterAllRemainingUsethefollowingtermsinthistable:NONE,ALL,ALLREMAININGorfillinthelettersofthesectorsaffected.Miles0-22-55-10>10NOACTIONEVACUATESHELTERUsethefoIINYingtermsinthistable:NONE,ALL,ALLREMAININGCDE0>yrcsici)DOSEorfillinthelettersofthesectorsaffected.Miles0-22-55-10>10NOACTIONEVACUATESHELTERfprfprFplporrsppcrtIf REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:54of58ATTACHMENT3DETERMINATIONOFPROTECTIVEACTIONRECOMMENDATIONSPARs(Page5of5)PARWORKSHEETTime/DateA.PARComparisonEmergencyClass:CISAE0GEAftercomparingthepossiblerecommendationsfromthePARsflowchart,themostconservativePARsarebasedon:(checkone)CIPLANTCONDITIONS0OFF-SITEDOSEB.ProtectiveActionsRecommendedbyFPL:Usethefollowingtermsinthistable:NONE,ALL,ALLREMAININGOrfillinthelettersofthesectorsaffected.0-2miles2-5miles5-10miles10-TBDmlles*NOACTIONSECTORSEVACUATESECTORSSHELTERSECTORS*Ifnecessary,addtoStateNotificationForm.ControlRoomSignatureEmergencyCoordinatorTechnicalSuortCenterSignatureTSCECAssistant/LogkeeperTSCHPSupervisororTSCChemistrySupervisorEmerenc0erationsFacilitSignatureEOFRMOPSAdvisor/LogkeeperENDOFATTACHMENT3EOFHPManager REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:55of58ATTACHMENT4NRCREACTORPLANTEVENTNOTIFICATIONWORKSHEET(Page1of2)NRCFORM361(12-2000)NOTIFICATIONTIMEREACTORPLANTEVENTNOTIFICATIONWORKSHEETFACILITYORORGANIZATIONUNITNAMEOFCALLERU.S.NUCLEARREGULATORYCOMMISSIONOPERATIONSCENTEREN¹CALLBACK¹EVENTTIME5.ZONEEVENTDATEPOWERMODEBEFOREPOWERMODEAFTEREVENTCLASSIFICATIONS1-Hr.Non.Emerenc10CFR50.72b1vASafoS/DCaabilitAINAGENERALEMERGENCYGEN/AAECTSDeviationADEVvBRHRCaabilitAINBSITEAREAEMERGENCYALERTUNUSUALEVENTSIT/AAECALE/AAECUNU/AAEC4-Hr.Non.Emerenc10CFR50.72b2ITSReulredS/DASHUivAECCSDischaotoRCSACCSvCControlofRadReleaseAINCvDAccidentMitlationAINDxliOffsltoMedicalAMED50.72NON.EMERGENCYseonextcoluinnsivBRPSActuationscrainARPSxiiiLossComm/Asmt/ResACOMPHYSICALSECURITY73.71MATERIAL/EXPOSUREFITNESSFORDUTYDDDDB7??HFITxlOffsitoNotificationAPRE60-Da0tlonal10CFR50.73a1S.Hr.Non.Emerenc10CFR50.72b3InvafidSectfiedSternActuationAINAiiADeradedConditionADEGOtherUnseclfledReulrementIdentlOTHERUNSPECIFIEDREQMT.seelastcolumniiBUnanaledConditionAUNANONRINFORMATIONONLYNNFivASedfiedSternActuationAESFNONRDESCRIPTIONInclude:Systemsaffected,actuatlonsandtheirinitiatingsignals,causos,effectofeventonplant,actionstakenorplannod,etc.(Continueonback)NOTIFICATIONSNRCRESIDENTSTATEsLOCALYESNOWILLBEANYTHINGUNUSUALORNOTUNDERSTOOD'0YES(Explainabovo)QNODIDALLSYSTEMSFUNCTIONASREQUIRED?0NO(Explainabove)OTHERGOVAGENCIESMEDIA/PRESSRELEASEForm¹PSL-F080MODEOFOPERATIONUNTILCORRECTED:ESTIMATEDRESTARTDATE:ADDITIONALINFOONBACK0YESDNOEPIP-08,Off-SiteNotificationsandProtectiveActionRecommendations,EffectiveDate:01/18/01andAP0010721,NRCRequiredNon-RoutineNotificationsandReports REVISIONNOJPROCEDURENOJEPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:56of58ATTACHMENT4$8NRCREACTORPLANTEVENTNOTIFICATIONWORKSHEET(Page2of2)RADIOLOGICALRELEASES:CHECKORFILLINAPPLICABLEITEMSseclficdetalls/exlanatlonsshouldbocoveredlneventdescrltlonLIQUIDRELEASEGASEOUSRELEASEUNPLANNEDRELEASEPLANNEDRELEASEONGOINGTERMINATEDMONITOREDUNMONITOREDOFFSITERELEASET.S.EXCEEDEDRMAtARMSAREASEVACUATEDPERSONNELEXPOSEDORCONTAMINATEDOFFSITEPROTECTIVEACTIONSRECOMMENDED'StatereleaseathindesciftlonNobleGasIodineParticulateLiquid(excludingtritiumanddissolvednobleasesLiuldtritiumTotalActivlReleaseRateCUsec%T.S.LIMITHOOGUIDE0.1Ci/sec10uCi/sec1uCi/sec10uCi/min0.2Ci/minTotalActlvlCl%T.S.LIMITHOOGUIDE1000Ci0.01Ci1mCI0.1Cl5CIRADMONITORREADINGSALARMSETPOINTS%T.S.LIMITIfappllcabloPLANTSTACKCONDENSER/AIREJECTORMAINSTEAMLINESGSLOWDOWNOTHERRCSORSGTUBELEAKS:CHECKORFILLINAPPLICABLEITEMS:specifidetails/exIanatlonsshouldbecoveredineventdescrltlonLOCATIONOFTHELEAK(o.g.,SG¹,valve,pipe,etc.)LEAKRATEUNITS:gpm/gpdT.S.LIMITSSUDDENORLONG-TERMDEVELOPMENTLEAKSTARTDATETIMECOOEANTACTIVITYPRIMARYANDUNITS:SECONDARYLISTOFSAFETYRELATEDEQUIPMENTNOTOPERATIONALEVENTDESCRIPTION(Continuedfromfront)FormffPSL-F080EPIP-08,Off-SiteNotificationsandProtectiveActionRecommendations,andAP0010721,NRCRequiredNon-RoutineNotificationsandReportsEffectiveDate:01/18/01ENDOFATTACHMENT4 REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:57of58$7ATTACHMENT4ADIRECTIONSFORCOMPLETINGTHENRCREACTORPLANTEVENTNOTIFICATIONWORKSHEET(Page1of2)Contactinformation-tobecompletedfollowingcontact1.NameofthepersoncontactingtheNRCorotherdesignatedFPLcontact.2.NRCContactsName-willbeprovideduponcontact.AlsoobtaintheeventnumberandnotificationtimeasreceivedfromtheHOOshouldberecordedonthetopoftheworksheet.ReactorPlantEventNotificationWorksheet,Page1NOTEThe"ENit"isrovidedhtheNRC.NotificationTime-enterthetimecontactismade.2.Unit-entertheappropriateunitnumber:Enter"0"foraclassificationcommontobothunits.3.4.5.6.7.CallersName-enterthenameofthepersonmakingthecall.Callback¹-enterthenumberoftheENSphonethatyouarecallingfromandthecommercialphonenumberatwhichyoucanbereached.EventtimeandZone-enterthemilitarytime,thezonewillbe"EST"forEasterStandardTimeor"EDT"forEasternDaylight-savingsTime.EventDate-enterthedatetheeventisoccurring.Power/ModeBefore&Power/ModeAfter-enterthepowerinpercentandthemodenumber(1-6)beforeandaftertheevent.NOTEAbbreviations/acronyms(e.g.,UNU/AAEC,SIT/AAEC,etc.)areforNRCuseonl.8.EventClassifications-checkoneofthefourblocksforGeneralEmergency,SiteAreaEmergency,Alert,orNotificationofUnusualEvent.
REVISIONNO.:PROCEDURENO.:EPIP-08PROCEDURETITLE:OFF-SITENOTIFICATIONSANDPROTECTIVEACTIONRECOMMENDATIONSST.LUCIEPLANTPAGE:58of58$7ATTACHMENT4ADIRECTIONSFORCOMPLETINGTHENRCREACTORPLANTEVENTNOTIFICATIONWORKSHEET(Page2of2)B.(continued)NOTENootherblocksintheuerhalfoftheformarereuired.9.Description-provideawrittendescriptionoftheevent.NOTEChecktheblocksinthelowerportionoftheformbasedoncurrentconditions.C.D.10.Modeofoperationuntilcorrected-providedifknown.11.Estimateforrestartdate-enter"unknown".12.AdditionalinfoonPage2-enteryesorno.ReactorPlantEventNotificationWorksheet,Page21.Fillinasmuchoftheinformationontheformasisimmediatelyavailable-donotcreateunduedelayinmakingthenotification.Thisinformationcanbegainedoncetheopenlineofcommunicationisestablished.ApprovalInformationenteredontheworksheetshallbereviewedandapprovedbytheECorRM(ifusedintheEOF),priortotransmission.2.TheEC/RMmayinitialontheworksheettoindicateapproval.Thereisnoformalsign-offlocationontheworksheet.ENDOFATTACHMENT4A Title:FPLST.LUCIEPLANTHEALTHPHYSICSPROCEDURESAFETYRELATEDProcedureNo.HP-203CurrentRevisionNo.18EffectiveDate06/15/01PERSONNELACCESSCONTROLDURINGEMERGENCIESResponsibleDepartment:HEALTHPHYSICSREVISIONSUMMARY:Revision18-THEPROCEDUREHASBEENCOMPLETELYREWRITTEN.StreamlinedRe-entrypaperwork.ChangedRadiationProtectionTechniciantoHealthPhysicsTechnician.DeletedTMIShieldingStudyreferenceandmaps,andmovedthemtoHP-201.Madeadministrativechanges.(D.Calabrese,04/26/01)PSIAOwoceoon~PAAIDurTIQNRevision0Revision18FRGReviewDate02/01/82FRGReviewDate04/26/01ApprovedByJ.H.Barrow(for)PlantGeneralManagerApprovedByR.G.WestPlantGeneralManagerN/ADesignatedApproverN/ADesignatedApprover(MinorCorrection)ApprovalDate02/04/82ApprovalDate04/26/01SQPSDATEDQCTPRQGEDUREDQCNHPP-203sYsCQMcoMPLETEDITM18
REVISIONNO.:18PROCEDURENO.:HP-203SECTION1.0PURPOSEPROCEDURETITLE:PERSONNELACCESSCONTROLDURINGEMERGENCIESST.LUCIEPLANTTABLEOFCONTENTSPAGE:2of14PAGE2.0PRECAUTIONSANDLIMITATIONS3.0DEFINITIONS
4.0REFERENCES
5.0RECORDSREQUIRED.6.0INSTRUCTIONSFORMSHP203.1EVACUATEDAREARE-ENTRYCHECKLIST.HP203.2EMERGENCYACCESSCONTROLLOGSHEETHP203.3EMERGENCYRESPONDERDOSECONTROLFORM..........HP203.4EMERGENCYEXPOSUREAUTHORIZATION..10...12.13 REVISIONNo.:18PROCEDURENO.:HP-203PROCEDURETITLE:PERSONNELACCESSCONTROLDURINGEMERGENCIESST.LUCIEPLANTPAGE:3of14NOTEInitialworkactivitiesdirectedbytheOSCSupervisor,attheALERTLEVEL,areconsideredpre-re-entryandcertainaspectsofthisproceduremayberelaxed(e.g.,HPpaperwork&coverage).FollowingasiteevacuationorderorifradiologicalconditionsexistoutsidetheRCA,allprovisionsofthisrocedurearereuiredforre-entintotheaffectedarea.1.0PURPOSE1.1Thisprocedureprovidesguidelinesforcontrolofpersonnelaccesstotheplantandradiologicallyaffectedareasduringandfollowinganemergency.2.0PRECAUTIONSANDLIMITATIONS2.1TheEmergencyCoordinator(EC)maywaivetherequirementsofthisproceduretoallowaccessforthesearchandrescueofinjuredorlostpersonnelortoplacetheplantinasafecondition.2.2Re-entryintotheplantfollowingevacuationduringanemergencyshallbemadeonlywhenauthorizedbytheEC.2.3Allre-entryteamsdispatchedfromtheOperationalSupportCenter(OSC)shallbebriefedbytheHPSupervisorintheOperationalSupportCenter(HPOSC)ontheradiologicalconditionsthatareknownorexpectedtobeencountered,theirallowedexposure,andprotectiveclothingandequipmentnecessary.2.4EntrytotheplantshallbethroughtheEastSecurityBuildingunlessotherwisedirectedbytheEC.2.5There-entryaccesscontrolpointisestablishedattheOSCatalocation(s)designatedbytheTechnicalSupportCenterHealthPhysicsSupervisor(TSCHPS).2.6TheECmayadjustaccesscontrolrestrictionsiftheplantconditionsandradiologicalconditionswarrant.
REVISIONNO.:18PROCEDURENo.:HP-203PROCEDURETITLE:PERSONNELACCESSCONTROLDURINGEMERGENCIESST.LUCIEPLANTPAGE:4of14CAUTIONThearearadiationmonitorsprovideonlythedoseratesatthedetectorlocations.Radiationlevelsinareasoutsidetheimmediatedetectorlocationsmabesinificantlhiher.2.7Entriesintoradiationareasexceeding10R/hrshouldnotbemadewithoutECorTSCHPSauthorization.2.8ExposuretoemergencyresponsepersonnelshouldbemaintainedAsLowAsReasonablyAchievable(ALARA).Actionstakenduringanemergencyshouldtakeintoconsiderationtheamountofexposurerequiredtoaccomplishthetaskversusthepotentialbenefittothepublichealthandsafety.2.9PersonnelshallberestrictedfromfurtherexposureiftheirDDEreaches5.0RemoriftheirthyroidCDEreaches50Rem.2.10Personnelreachingthedoselimitsin2.9abovemaybeallowedtoreceiveadditionalexposureafteradeterminationofdosehasbeenfinalizedbythereadingoftheirTLDorbioassayasappropriate.3.0DEFINITIONS3.1Re-entry-Accesstoareaswhereevacuation(localorsite)hasbeenorderedconstitutesare-entry.Re-entryintoanevacuatedareaisauthorizedonlybytheEmergencyCoordinator(EC).3.2Re-entryTeam-AgroupofqualifiedpersonnelwhowillenteranevacuatedareaundertheauthorizationoftheECtoaccomplishanassignedtask(e.g.,rescue,damagecontrol,repair,etc.).TheinitialRe-entryTeamshallconsistofatleasttwopersonsoneofwhomshallbeanOSCHealthPhysicsTechnician.(HPT).
REVISIONNo.:18PROCEDURENo.:HP-203PROCEDURETITLE:PERSONNELACCESSCONTROLDURINGEMERGENCIESST.LUCIEPLANTPAGE:5of1
44.0REFERENCES
NOTEOneormoreofthefollowingsymbolsmaybeusedinthisprocedure:gIndicatesaRegulatorycommitmentmadebyTechnicalSpecifications,ConditionofLicense,Audit,LER,Bulletin,OperatingExperience,etc.andshallNOTberevisedwithoutFacilityReviewGroupreviewandPlantGeneralManagerapproval.Indicatesamanagementdirective,vendorrecommendation,plantpracticeorothernon-regulatorycommitmentthatshouldNOTberevisedwithoutconsultationwiththeplantstaff.'FIndicatesastethatreuiresasinoffonanattachment.4.1St.LuciePlantRadiologicalEmergencyPlan(E-Plan)4.2E-PlanImplementingProcedures(EPIP00-13).4.3NuclearEnergyPolicyonExposureLimitsforEmergencyResponsePersonnel,RevisiontoPolicyStatement,LtrNo.JNO-HP-94-056,October26,1994.4.4HP-112,Multibadging4.5HP201,EmergencyPersonnelExposureControl4.6HP-206,AnalysisofEmergencyIn-plantAirSamples4.7tt~ConditionReport,CR-01-0078,OSCRe-EntryTeamPerformance REVISIONNO.:18PROCEDURENO.:HP-203PROCEDURETITLE:PERSONNELACCESSCONTROLDURINGEMERGENCIESST.LUCIEPLANTPAGE:6of145.0RECORDSREQUIRED5.1ThefollowingdocumentswhencompletedshallbemaintainedintheplantfilesinaccordancewithQl-17-PSL-1"QualityAssuranceRecords."FormHP203.1,EvacuatedAreaRe-entryAuthorizationandanyattachments2.3.4.FormHP203.2,EmergencyAccessControlLogSheetFormHP203.3,EmergencyResponderDoseControlFormFormHP203.4,EmergencyExposureAuthorization REVISIONNO.:18PROCEDURENO.:HP-203PROCEDURETITLE:PERSONNELACCESSCONTROLDURINGEMERGENCIESST.LUCIEPLANTPAGE:7of146.0INSTRUCTIONS6.1TheHealthPhysicsrepresentativeinchargeofHPactivitiesattheOSC(HPOSC)isresponsibleforensuringaccesscontroltoradiologicallyaffectedareas.TheHPOSCshouldperformthefollowingsteps:ContacttheTSCHPStodeterminewheretheaccesscontrolpoint(s)aretobeestablished.2.3.4.5.6.7.SelectanOSCHPTech(HPT)tomantheaccesscontrolpoint(s).BrieftheRe-entryTeammembersontheconditionswithintheareasusingavailableinformationfromsurveysandareamonitors.Evaluatetheneedformultibadgesorextremitymonitoring.InstructtheRe-entryTeammembersthatnooneispermittedtoentertheareawithoutprovidingacompletedEvacuatedAreaRe-entryAuthorizationform(HP-203.1)unlessauthorizedbytheNuclearPlantSupervisor(NPS)/EmergencyCoordinator(EC).CompleteformHP-203.1foreachRe-entryTeam.InstructtheRe-entryTeammembersthatinitialentryintoanevacuatedareamustbemadebyatleasttwopeople,oneofwhommustbeanOSC.HPT.8.9.CoordinatewithRe-entrySupervisorsonselectionofRe-entryTeammembers(exposurehistories,respiratoryqualificationstatus,authorizationtoexceed10CFRPart20exposurelimits,etc.).CompleteFormHP-203.4,"EmergencyExposureAuthorization,"foreachRe-entryTeamwhichmayexceedthe10CFRPart20exposurelimits.ENDOFSECTION6.1 REVISIONNO.:18PROCEDURENO.:HP-203PROCEDURETITLE:PERSONNELACCESSCONTROLDURINGEMERGENCIESST.LUCIEPLANTPAGE:8of146.2TheOSCHPTattheaccesscontrolpointshouldperformthefollowingsteps:1.Positionhimselfinsuchamannerthatpersonnelaccessingtheareamustpassbyhim.2.ReviewformHP203.1toensurethattheindividualisauthorizedentryandthattheindividualhastherequiredprotectiveequipmentspecifiedbytheHPOSC.3.DenyaccesstoanyonewhodoesnothaveacompletedHP203.1ordoesnothavealltherequiredequipmentaslistedontheform.4.LogtheindividualintotheareaontheEmergencyAccessControlLogSheetform(HP203.2)foreachindividualenteringthearea.5.Whenanindividualexitsfromthearea,completethelogentryonformHP203.2.6.ReporttotheHPOSCanypersonnelcontaminationorexposuresinexcessoftheallowedexposure.7.EnsurethatpersonnelmonitoringdevicesaretakenbytheindividualtotheOSCforfurtherprocessingandrecording.8.Checkitemsremovedfromtheareaforcontamination.9.Intheeventthatanindividualiscontaminated,detaintheindividualandrequestassistancefromtheHPOSCtoescortanddecontaminatehim.10.RecordanysurveydatatakenbytheRe-entryteamintheRemarkssectionoftheEvacuatedAreaRe-entryAuthorizationform(HP203.1)asdoserateinformationforfutureentries.TransmitthisinformationtotheHPOSCalso.ENDOFSECTION6.2 REVISIONNO.:18PROCEDURENO.:HP-203PROCEDURETITLE:PERSONNELACCESSCONTROLDURINGEMERGENCIESST.LUCIEPLANTPAGE:9of146.3TheOSCDosimetryTechnicianperformsthefollowing:3.IssueTLDstopersonnelnotinpossessionoftheirregularTLD.Checkrespiratorqualsofre-entryteammembers.Attheconclusionofthere-entry,thedosereceivedbytheindividualshallbeenteredonformHP-203.3,"EmergencyResponseDoseControl,"tomaintainacurrentdoserecordofDDEandCDE(Thyroid)fortheindividual~ItshouldbeenteredafterairsampleresultshavebeendeterminedinaccordancewithHP-206,"AnalysisofEmergencyIn-plantAirSamples."ENDOFSECTION6.3 REVISIONNO.:18PROCEDURENo.:HP-203PROCEDURETITLE:PERSONNELACCESSCONTROLDURINGEMERGENCIESST.LUCIEPLANTPAGE:10of14HP203.1EVACUATEDAREARE-ENTRYCHECKLIST(Page1of1)TEAMNO.DoseandDosimetry1.TeammembernamesandTLDnumberstoDosimetry2.Exposurelimits3.Doseextension-refertoFormHP-203.44.AppropriatedosimetryRespiratoryProtection1.SCBA2.Respirator3.OtherDress-out1.Dress-outrequirementsBriefing1.Radiologicalconsiderations2.Ingress/egress3.Staytimes4.Decon5.OtherCompletedby:Date:~//Form¹PSL-F090HP-203,PERSONNELACCESSCONTROLDURINGEMERGENCIESEffectiveDate:0915/01 REVISIONNO.:18PROCEDURENo.:HP-203PROCEDURETITLE:PERSONNELACCESSCONTROLDURINGEMERGENCIESST.LUCIEPLANTHP203.2EMERGENCYACCESSCONTROLLOGSHEET(Page1of1)PAGE:11of14Date//NameTLDffLocationTimeInTimeOutInit.
EVISIONNo.:18ROCEDURENo.:HP-203PROCEDURETITLE:PERSONNELACCESSCONTROLDURINGEMERGENCIESST.LUCIEPLANTPAGE:12of14HP203.3EMERGENCYRESPONDERDOSECONTROLFORM(Page1of1)Name:TLD¹:Department:DateAirTimeInTimeOutSampleNo.GammaDose(DDE)Limit(mrem)GammaDose(DDE)ThisEntry(mrem)PreviousGammaDose(DDE)Total(mrem)UpdateGamma(1)Dose(DDE)Total(mrem)ThyroidDoseLimit(CDE)(mrem)ThyroidDose(CDE)ThisEntry(mrem)PreviousThyroidDose(CDE)Total(mrem)UpdatedThyroid(2)Dose(CDE)Total(mrem)(1)GammaDose(DDE)Limitshallnotexceed5,000mremwithoutECauthorization(2)ThyroidDose(CDE)Limitshallnotexceed50,000mremwithoutECauthorization REVISIONNo.:18PROCEDURENO.:HP-203PROCEDURETITLE:PERSONNELACCESSCONTROLDURINGEMERGENCIESST.LUCIEPLANTPAGE:13of14HP203.4EMERGENCYEXPOSUREAUTHORIZATION(Page1of2)I.TeamInformation~Name/DetTLD~Sinature*Date/Time2.3.4.*Yoursignatureindicatesthatyouhavereceivedandunderstandthebriefinginformationregardingtherisksassociatedwiththisexposure.II.ReasonforEntryIII.AuthorizationExposureLimit:EmergencyCoordinator":RecoveryManager":TSCHPS':Date:Date:Date:'Signaturemaybeauthorizedbyphone'SignaturenotmandatoryIV.BriefingInformationA.Forexposuresexceeding5remTEDEor100remCDE:1.Personsshouldbevolunteersandexperiencedatthetaskrequiringthere-entry(forexpectedexposuresexceeding25remTEDEor250remCDE,personsshouldbeabovetheageof45).2.Personsshallhavefullawarenessofrisksinvolvedincludingnumericallevelsofdoseatwhichacuteeffectsofradiationwillbeincurredandnumericalestimatesoftheriskofdelayedeffects.(Seebelow)
REVISIONNo.:18PROCEDURENo.:HP-203PROCEDURETITLE:PERSONNELACCESSCONTROLDURINGEMERGENCIESST.LUCIEPLANTPAGE:14of14HP203.4EMERGENCYEXPOSUREAUTHORIZATION(Page2of2)B.Effectsfromanacutedoseofradiation:Prompt'.5-100RemMinorchangesintheblood,likereducedwhitecellandplateletcounts.b.>100RemCancausenausea,vomiting,fatigue,lossofappetite,andlossofhair,severityincreaseswithincreaseddose.c.>450RemCanbefatalwithoutpropermedicalcare.2.Delayed-Cancer/LifeSpan',consulttablebelow:AgeatExposure21-3031-4041-5051-6061-7010RemExposureCancerRiskApprox.<0.3%<0.3%40<0.3%31<0.3%21<0.3%1225RemExposureApprox.CancerRiskDaysLost<0.7%124<0.7%100<0.7%77<0.7%65<0.7%293.Delayed-GeneticEffects'.OneRemresultsinanestimatedriskofgenetically-relateddisordersinallgenerations(currentandfuture)of1x10E-4perperson-rem(or1in10,000).
References:
'napp,S.andM.Cooper,1995.ALayman'sGuidetoRadiationSafety,FPLSt.LucieNuclearPlant,Ft.Pierce,Florida86pp.DerivedfromCohen,BernardL.,1990.TheNuclearEnergyOption,PlenumPublicationCorporation,NewYork,NewYork,338pp.EPA400-R-92-001,ManualofProtectiveActionGuidesandProtectiveActionsforNuclearIncidents,AppendixBOfficeofRadiationProgramsUSEPA,Washington,DC,p.B-23.