St. Lucie Unit 2 Docket No. 50-389 Proposed License Amendment
~ Boron Dilutio I terim L TTA HMENT 3 to L-99-010 ST. LUCIE UNIT2 MARKED-UPTECHNICALSPECIFICATION PAGES INDEXPage IV LIST OF TABLES Page XXIII Page 3/41-16 Page 3/41-17 Page B 3/4 1-3 9903030i84 990223 PDR ADQCK 05000389
.P
. PDR
INDEX LIMITING CONDITIONS FOR OPERATION AND SURVEILLANCE RE UIREMENTS SECTION 3/4. 0 APPLICABILITY.................................
PAGE 3/4 0-1 3/4. 1 REACTIVITY CONTROL SYSTEMS 3/4-1 ~ 1 BORATION CONTROL SHUTDOWN MARGIN - T
>200 F...........
SHUTDOWN MARGIN - T <200 F...........
BORON DILUTION.
MODERATQR TEMPERATURE COEFFICIENT..
MINIMUMTEMPERATURE FOR CRITICALITY.
3/4 l-l 3/4 1-3 3/4 1-4 3/4 1-5 3/4 1-6 3/4. 1. 2 BQRATIQN SYSTEMS FLOW PATHS - SHUTDOWN.
FLOW PATHS OPERATING..............
CHARGING PUMPS - SHUTDOWN.
CHARGING PUMPS - QPERATING..........
BORIC ACID MAKEUP PUMPS - SHUTDOWN..
BORIC ACID MAKEUP PUMPS " OPERATING.
BORATED WATER SOURCES SHUTDOWN.
BORATED WATER SOURCES - OPERATING...
-BOReN-DWUTW.
3/4 1-7 3/4 1"8 3/4 1-9 3/4 1-XQ 3/4 1"11 3/4 1"12 3/4 1-13 3/4 1-14 3/4.1.3 MQVABLE CONTROL ASSEMBLIES CEA POSITION.
~ 0 ~ ~ ~ ~ ~ ~ t ~ 0 ~ ~ ~ ~ t ~ t 0 ~ ~ 0 ~ ~ 0 1 \\
POSITION INDICATOR CHANNELS - OPERATING........
POSITION INDICATOR CHANNELS -
SHUTDOWN.
CEA DROP TIME..
~ 0 ~
~ ~
~ I
~
10 ~
~ i 0
~ ~ ~ ~ i ~ ~
SHUTDOWN CEA INSERTION LIMIT...................
REGULATING CEA INSERTION LIMITS 3/4 1-18 3/4 1-21 3/4 1-23 3/4 1-24 3/4 1-25 3/4 1-26 ST..
LUCIE - UNIT 2 IV
>g~~P Po.
FREQUENCY NOTATION 1-8 1.2 OPERATIONALMODES 1-9 2.2-1 REACTOR PROTECTIVE INSTRUMENTATIONTRIP SETPOINT LIMITS
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
o 2A 3.1-1 WGNR-BRING-FREGUENGIES-FGFH3A EFHrFIel+FBR~UGI GRet+BIEFRGN-3.2-1 DELETED..
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
42 11 3.2-2 DNB MARGINLIMlTS 3/4 2-15 3.3-1 REACTOR PROTECTIVE INSTRUMENTATION...........
3/4 3-2 3.3-2 DELETED..
4.3-1 REACTOR PROTECTIVE INSTRUMENTATIONSURVEILLANCE REQUIREMENTS 3/4 3-8 303 3 3.3-4
~
~
~
~ \\
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
o 3/43 12 3/4 3-17 ENGINEERED SAFETY FEATURES ACTUATIONSYSTEM INSTRUMENTATION ENGINEERED SAFETY FEATURES ACTUATIONSYSTEM INSTRUMENTATIONTRIP VALUES.................
335
~3 5 DEL em D
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
4.3-2 ENGINEERED SAFETY FEATURES ACTUATIONSYSTEM INSTRUMENTATIONSURVEILLANCEREQUIREMENTS.............
3/4 3-22 3.3-6 RADIATIONMONITORING INSTRUMENTATION...
3/4 3-25 4.3-3 RADIATIONMONITORING INSTRUMENTATIONSURVEILLANCE REQUIREMENTS..
3/4 3-28 3.3-8 DELETED..
4.3-5 DELETED..
ST. LUCIE - UNIT2 XXIII Amendment No. e, ea. ~gtt
ORON ILUTION LIMITING C DITION FOR OPERATION 3.1.2.9 Boron oncentration shall be verified consistent with SHUTDO MARGIN requirements of ecifications 3.1.1.1, 3.1.1.2,, and 3.9.1.
APPLICABILITY:
a.
MODES 3, 4, nd 5 with RCS level above the hot nterline by use of boronomete or sampling per Table 3.1-1, n
h b.
ACTION:
MODE 5 with RCS vel below the hot leg sampling per Table 3.1-1.
n erl e;
and MODE 6 by ao b.
With the boron concentr tion not co t nt with required SHUTDOWN MARGIN, initiate emergen bo atio If unable to determine he ro concentration by the means speci-fied above, immediatel s sp d al operations involving CORE ALTERATIONS or positive ea i i changes until one of the means of determining g4 bo n co entration as specified above is restored,to OPE LE s tus.
C.
The provisions of e
fica on
.0.
are not applicable.
SURVEILLANCE REOUIREMENTS 4.1.2.9 a0 When in MODES 3 4, 5, a
6, the boron concent ation shall be determined co istent h
SHUTDOWN MARGIN requi ements once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />.
c The boron meter when used to monitor boron concentr tion, shall be demonstr ted ERABLE by performance of:
1.
C NEL CHECK once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, and 2.
a CHANNEL CALIBRATION once per 18 months.
enever performing an RCS heatup or cooldown, determine the ron concentration at least once eve 50 F chan e in tern erature..
~e~e N/N'
~7 (Amevd~e I A.,&) 4ae he~ daleIed ~ +Nc
'L~OICQ ae'e <~Ops-Ill,yH~
C LS ~A I - l8 ~
ST.
LUCIE " UNIT 2 3/4 1-16
~w nl0.
1
TABLE 3.1-1 MONITORING FREQUENCIES FOR BACKUP BORON DILUTION DETECTIO FOR ST.
LUCIE-2 MODE Number of OPERABLE Charging Pu s*
0 1
2 3
12 hr 100 min 40 min 25 min 5
(RCS level below hot leg centerline) 12 hr 130 min 50 min 30 min hr 100 min 40 n
25 min 8
h 35 min 0 eration not Operation not llowed**
allowed**
24 hr 2
in 95 min 55 min
- Charging pump OPERABILITY for an per' of time shall constitute OPERABILITY for the entire moni ring f quency.
I
~ *
~
I
- In MODE 5 with the RCS lev below the h
leg centerline, at least two charging pumps shall e verified to be inoperable by racking out their motor circuit bre ers.
P E
lt V
QpLp~p ~i J PAs~
LUCIE-UNIT 2 3/4 1-17 Amendment No.
~ q I
-,,* ""REACTIVITY CONTROL SY S
The OPERABILITY of one boron injection system during REFUELING ensures that this system is available for reactivity control while in YlODE 6.
The limits on contained water volume and boron concentration of the RlIT also ensure a pH value of between 7.0 and 8.0 for the solution recirculated within containment after a LOCA.
This pH band minimizes the evolution of iodine and minimizes the effect of chloride and caustic stress corrosion on mechanical systems and components.
8RBNHKtFR6 The simulta u
e of the boronometer and RCS.s a
intervals dependent upon the MODE an e-agnber of OP c arging.pumps to monitor and redundant indications of an liow de io with sufficient time fo before a complete SHUTDON the RCS boron concentration provi inadvertent boron di~lut' 7 zs will termination
- ~oron di1 ution even curs.
-3/4.1.3 MOYABLE CONTROL ASSEMBLIES The specifications of this section ensure that (1) acceptable power distribution limits are maintained, (2} the minimum SHUTDOWN MARGIN is main-
- tained, and (3) the potential effects of CEA misalignments are limited to acceptable levels.
The ACTION statements which permit limited variations from the basic requirements are accompanied by additional restrictio'ns which ensure that the original design criteria are met.
The ACTION statements applicable to a stuck or untrippable CEA, to two or more inoperable CEAs and to a large mi.salignment (greater than or equal to 15 inches) of two or more CEAs, require a prompt shutdown of the reactor since either of these conditions may. he indicative of a possible loss of mechanical functional capability of the CEAs and in the event of a stuck or untrippab'.e CEA, the loss of SHUTDOWN MARGIN.
'or small misaliqnments (less than 15 inches) of the CEAs, there is (1) a small effect on the tame-dependent long-term power distributions relative to those used in generating LCOs and LSSS setpoints, (2) a small effect on the available SHUTDOWN MARGIN, and (3) a small effect on the ejected CEA worth ~sed in the safety analysis.
Therefore, the ACTION statement associated with smal1 misalignments of CEAs permits a 1-hour time interval during which attempts may be made to restore the CEA to within its alignment requirements.
The 1-hour time limit is sufficient to {1) identify causes of a misaligned
- CEA, (2) take appropriate corrective action=to realign the CEAs, and (3) minimize the effects of xenon redistribution.
The contained water volume limits includes allowance for water not available because of discharge line location and other physical characteristics.
ST.
LUCIE - UNIT 2 8 3/4 1-3 Amendment No.
~ '