| title = LER#78-060/03L-0 on 770718:during Review of Surveillance Test Records It Was Determined That Monthly Test for 1B Rprw Pump Was Not Performed by 770718 as Req.Caused by Improper Sched of Surveillance Test
| title = /03L-0 on 770718:during Review of Surveillance Test Records It Was Determined That Monthly Test for 1B Rprw Pump Was Not Performed by 770718 as Req.Caused by Improper Sched of Surveillance Test
| author name = Werling J
| author name = Werling J
| author affiliation = DUQUESNE LIGHT CO.
| author affiliation = DUQUESNE LIGHT CO.
Line 17: Line 17:


=Text=
=Text=
{{#Wiki_filter:}}
{{#Wiki_filter:'
N*.C#CRnt M                  ,                                            y                        '
U. S. NOCLE A3 REGULATEY COMMISSION (7 77)                                                                    ,
                      .                                                          ' LICENSEE EVENT REPORT' CONTROL BLOCic l                  l-  'l \l          l l -lh  e (PLEASE PRINT OR TYPE ALL REOUIRED INFORMATIONI a
fo IIl8 l9P l AL6CENSEE 7
l B l CODE  V l S l 1 l@l  to    tw 0'- l 0 l- l LICENSE 0 l0 lNuusER 0 l 0 l 0 l- l0 l 0 l@l4    2S      ;8 l1  l1 l1 l 1 l@lSJ CATSd L6 CENSE Tvrt JJ l    l@
CON'T                                                          +
o              [,] l L @l 0 l 5-l 0 l 010 l 3 l 3 l a @l O f 71 1181 717 @ll 12 l2 l 2 l 7 l R                                        14                                  80 lh 7        8                      to            63            00CK ET NUMSER                  G1    63        EVENT DATE                        15        REPCRT DATE EVENT OESCRIPTION AND PRO 8A8LE CONSEOUENCEd h                                        ,
o 2 l During a review of surveillance test records, it was determined that the monthlv                                                                                                l o          l test      for the IB Re'ctor            a        Plant River Water (RPRh*) Pump was not performed by 7/18/77 l o 4        l as required.                      Howevet, it was perhormed satisfactorily on 7/22/77.                                                                                  l o s l                                                                                                                                                                                I o 6 l                                                                                                                                                                                  l s
o 7        l
                                                                                                                \                                                                          l
( al l e .                                                                                                                                                                                      l SYSTEM              CAUSE          . CAUSE -                                                          COMP.          VALV E COCE                CCDE            SU8COCE                COMPONENT CODE                          SUSCODE          SUSCODE 7
o 9 8
lW l A l@ ]@ l BI@ l -13PlU lM lP l X l X lh W@ W @
8          10          31        i      12                                                18          19              20
                                    ,. ?  s .I                ,                  SEQUENTI AL                          OCCURRENCE              REPORT                    REVISION LER          evENTYEAR                                    REPORT NO.                                CODE                TYPE                      NO.
                  @ ,ago/Ro  g l237122 a l , 23l--J                              10 I 61 al 24            28 Ld 27 1013 l 28        29 l tl 30 L-J 38 1 01 32 KN AC O                    O P NT              ME                          HOURS              SS IT                POR      8. SUP L1            MANUF CTURER l X l@[_Z_j@
33        34 l36 Zl@            (_Zj@
36                3 Ol 0l Ol 0 l 40 lNl@
di lNl@
42 l43 Al@      lBl5l8lOl@
44            47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS i o l The incident resulted from improper scheduline of the surveillance test.                                                                                        The            I
      , i        l 1A RPRW Pump was tested twice during the month while the 1B RPRW Pump was omitted.                                                                                      I
{ g l The surveillance tests are now being tracked on a computer program to insure proper [
g l scheduling of the tests.                                                                                                                                                            l E .I
    ,      8 80 I
ST                  %PowfR                          OTHER STATUS                    ISCO RY                                  OtSCoVERY DESCRIPTION 1 s        (_Ej@ l l l 0 l 0 l@l                              N/A                        l    lCl@l                Records review                                                  l A TivtTY CO TENT RnEASE        saELEASE                                                                                                        toCATiON Cs RELEASE h i 6 8 9
                                        @l                AuOuNT  N/A                OP ACTIVITY 44 l
44 hl                        N/A                              l 7                          10                                                                                                                                                      80 PERSONNEL ExPOSumt NUV8ER              TYPE          DESCRIPTION I 7 l010l0l@lZl@l    '                    ''
N/A l
                ' PERSONNE't maddit$
Nuv8tR              DESCRIPTION 7
i a 8 9 10l0l0l@l      11        12 N/A 80 l
      ' 9
                '#5E '"'"",'''''""@
ES R T ON N/A 78122S O}A1 Lz_1@l                                                                                                                                                                  l 7        8 9            to                                                                                                                                                          80 DE CRIPT60N
* 2 o      ISSdUEL 81                                          N/A                                                                                  i    i i i iiiiiii i i li 7        8 9            to                                                                                                                            68 69                          60 3 NAME OF PREPARER
                                                                      *
* UE
* PHONE:
412-643-1258
{'}}

Latest revision as of 23:04, 31 May 2023

/03L-0 on 770718:during Review of Surveillance Test Records It Was Determined That Monthly Test for 1B Rprw Pump Was Not Performed by 770718 as Req.Caused by Improper Sched of Surveillance Test
ML20064J226
Person / Time
Site: Beaver Valley
Issue date: 12/22/1978
From: Werling J
DUQUESNE LIGHT CO.
To:
Shared Package
ML20064J198 List:
References
LER-78-060-03L, LER-78-60-3L, NUDOCS 7812290227
Download: ML20064J226 (1)


Text

'

N*.C#CRnt M , y '

U. S. NOCLE A3 REGULATEY COMMISSION (7 77) ,

. ' LICENSEE EVENT REPORT' CONTROL BLOCic l l- 'l \l l l -lh e (PLEASE PRINT OR TYPE ALL REOUIRED INFORMATIONI a

fo IIl8 l9P l AL6CENSEE 7

l B l CODE V l S l 1 l@l to tw 0'- l 0 l- l LICENSE 0 l0 lNuusER 0 l 0 l 0 l- l0 l 0 l@l4 2S ;8 l1 l1 l1 l 1 l@lSJ CATSd L6 CENSE Tvrt JJ l l@

CON'T +

o [,] l L @l 0 l 5-l 0 l 010 l 3 l 3 l a @l O f 71 1181 717 @ll 12 l2 l 2 l 7 l R 14 80 lh 7 8 to 63 00CK ET NUMSER G1 63 EVENT DATE 15 REPCRT DATE EVENT OESCRIPTION AND PRO 8A8LE CONSEOUENCEd h ,

o 2 l During a review of surveillance test records, it was determined that the monthlv l o l test for the IB Re'ctor a Plant River Water (RPRh*) Pump was not performed by 7/18/77 l o 4 l as required. Howevet, it was perhormed satisfactorily on 7/22/77. l o s l I o 6 l l s

o 7 l

\ l

( al l e . l SYSTEM CAUSE . CAUSE - COMP. VALV E COCE CCDE SU8COCE COMPONENT CODE SUSCODE SUSCODE 7

o 9 8

lW l A l@ ]@ l BI@ l -13PlU lM lP l X l X lh W@ W @

8 10 31 i 12 18 19 20

,. ? s .I , SEQUENTI AL OCCURRENCE REPORT REVISION LER evENTYEAR REPORT NO. CODE TYPE NO.

@ ,ago/Ro g l237122 a l , 23l--J 10 I 61 al 24 28 Ld 27 1013 l 28 29 l tl 30 L-J 38 1 01 32 KN AC O O P NT ME HOURS SS IT POR 8. SUP L1 MANUF CTURER l X l@[_Z_j@

33 34 l36 Zl@ (_Zj@

36 3 Ol 0l Ol 0 l 40 lNl@

di lNl@

42 l43 Al@ lBl5l8lOl@

44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS i o l The incident resulted from improper scheduline of the surveillance test. The I

, i l 1A RPRW Pump was tested twice during the month while the 1B RPRW Pump was omitted. I

{ g l The surveillance tests are now being tracked on a computer program to insure proper [

g l scheduling of the tests. l E .I

, 8 80 I

ST %PowfR OTHER STATUS ISCO RY OtSCoVERY DESCRIPTION 1 s (_Ej@ l l l 0 l 0 l@l N/A l lCl@l Records review l A TivtTY CO TENT RnEASE saELEASE toCATiON Cs RELEASE h i 6 8 9

@l AuOuNT N/A OP ACTIVITY 44 l

44 hl N/A l 7 10 80 PERSONNEL ExPOSumt NUV8ER TYPE DESCRIPTION I 7 l010l0l@lZl@l '

N/A l

' PERSONNE't maddit$

Nuv8tR DESCRIPTION 7

i a 8 9 10l0l0l@l 11 12 N/A 80 l

' 9

'#5E '"'"",""@

ES R T ON N/A 78122S O}A1 Lz_1@l l 7 8 9 to 80 DE CRIPT60N

  • 2 o ISSdUEL 81 N/A i i i i iiiiiii i i li 7 8 9 to 68 69 60 3 NAME OF PREPARER
  • UE
  • PHONE:

412-643-1258

{'