ML16061A565: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(StriderTol Bot change)
 
(4 intermediate revisions by the same user not shown)
Line 2: Line 2:
| number = ML16061A565
| number = ML16061A565
| issue date = 03/09/2016
| issue date = 03/09/2016
| title = Oconee Nuclear Station, Units 1, 2, and 3 - Request for Additional Information for Relief Request 14-ON-001, Letdown Cooler Nozzle Welds (CAC Nos. MF6290, MF6291 and MF6292)
| title = Request for Additional Information for Relief Request 14-ON-001, Letdown Cooler Nozzle Welds
| author name = Hall J R
| author name = Hall J
| author affiliation = NRC/NRR/DORL/LPLII-1
| author affiliation = NRC/NRR/DORL/LPLII-1
| addressee name = Markley M T
| addressee name = Markley M
| addressee affiliation = NRC/NRR/DORL/LPLII-1
| addressee affiliation = NRC/NRR/DORL/LPLII-1
| docket = 05000269, 05000270, 05000287
| docket = 05000269, 05000270, 05000287
| license number = DPR-038, DPR-047, DPR-055
| license number = DPR-038, DPR-047, DPR-055
| contact person = Hall J R, NRR, DORL, 415-4032
| contact person = Hall J, NRR, DORL, 415-4032
| case reference number = CAC MF6290, CAC MF6291, CAC MF6292
| case reference number = CAC MF6290, CAC MF6291, CAC MF6292
| document type = Memoranda, Request for Additional Information (RAI)
| document type = Memoranda, Request for Additional Information (RAI)
Line 18: Line 18:


=Text=
=Text=
{{#Wiki_filter:MEMORANDUM TO: FROM:  
{{#Wiki_filter:UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 March 9, 2016 MEMORANDUM TO:             Michael T. Markley, Chief Plant Licensing Branch 11-1 r
Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation                    1I () n FROM:                     James R. Hall, Senior Project Manager Plant Licensing Branch 11-1 f' 1~
Division of Operating Reactor Licensing, Office of Nuclear Reactor Regulation


==SUBJECT:==
==SUBJECT:==
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 March 9, 2016 Michael T. Markley, Chief Plant Licensing Branch 11-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation 1 I () n James R. Hall, Senior Project Manager r f' Plant Licensing Branch 11-1 Division of Operating Reactor Licensing, Office of Nuclear Reactor Regulation OCONEE NUCLEAR STATION, UNITS 1, 2, AND 3-REQUEST FOR ADDITIONAL INFORMATION FOR RELIEF REQUEST 14-0N-001, LETDOWN COOLER NOZZLE WELDS (CAC NOS. MF6290, MF6291 AND MF6292) By letter dated May 4, 2015 (Agencywide Documents and Access Management System (ADAMS) Accession No. ML15132A279), Duke Energy Carolinas, LLC, (the licensee) requested the Nuclear Regulatory Commission (NRC) to authorize relief from Section XI of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) related to inspection of the inside radius sections of the Letdown Cooler nozzles over the duration of the fifth (ten-year) in-service inspection (ISi) interval.
OCONEE NUCLEAR STATION, UNITS 1, 2, AND 3- REQUEST FOR ADDITIONAL INFORMATION FOR RELIEF REQUEST 14-0N-001, LETDOWN COOLER NOZZLE WELDS (CAC NOS. MF6290, MF6291 AND MF6292)
On February 25, 2016, the NRC staff and the licensee held a clarifying discussion on the staff's draft request for additional information (RAI), transmitted via e-mail on January 7, 2016 (ADAMS Accession No. ML 16008A246).
By letter dated May 4, 2015 (Agencywide Documents and Access Management System (ADAMS) Accession No. ML15132A279), Duke Energy Carolinas, LLC, (the licensee) requested the Nuclear Regulatory Commission (NRC) to authorize relief from Section XI of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) related to inspection of the inside radius sections of the Letdown Cooler nozzles over the duration of the fifth (ten-year) in-service inspection (ISi) interval.
Based on that discussion, the NRC staff developed the attached final RAI, and requested that the licensee submit written responses to the revised questions, so that the staff can complete its review of the subject relief request. Docket Nos. 50-269, 50-270, and 50-287  
On February 25, 2016, the NRC staff and the licensee held a clarifying discussion on the staff's draft request for additional information (RAI), transmitted via e-mail on January 7, 2016 (ADAMS Accession No. ML16008A246). Based on that discussion, the NRC staff developed the attached final RAI, and requested that the licensee submit written responses to the revised questions, so that the staff can complete its review of the subject relief request.
Docket Nos. 50-269, 50-270, and 50-287


==Attachment:==
==Attachment:==
Final RAI cc w/attachment: Distribution via Listserv


Final RAI cc w/attachment:
FINAL REQUEST FOR ADDITIONAL INFORMATION RELIEF REQUEST 14-0N-001 LETDOWN COOLER NOZZLE WELDS OCONEE NUCLEAR STATION, UNITS 1, 2 AND 3 DUKE ENERGY CAROLINAS, LLC DOCKET NOS. 50-269, 50-270 AND 50-287 By letter dated May 4, 2015 (Agencywide Documents and Access Management System (ADAMS) Accession No. ML15132A279), Duke Energy Carolinas, LLC, (the licensee) requested the Nuclear Regulatory Commission (NRC) to authorize relief from Section XI of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) related to inspection of the inside radius sections of the Letdown Cooler nozzles over the duration of the fifth (ten-year) in-service inspection (ISi) interval. This relief request applies to the Oconee Nuclear Station, Units 1, 2 and 3. The licensee is requesting renewal of previously granted relief requests based on the impracticality of performing inspections in the specified areas.
Distribution via Listserv FINAL REQUEST FOR ADDITIONAL INFORMATION RELIEF REQUEST 14-0N-001 LETDOWN COOLER NOZZLE WELDS OCONEE NUCLEAR STATION, UNITS 1, 2 AND 3 DUKE ENERGY CAROLINAS, LLC DOCKET NOS. 50-269, 50-270 AND 50-287 By letter dated May 4, 2015 (Agencywide Documents and Access Management System (ADAMS) Accession No. ML 15132A279), Duke Energy Carolinas, LLC, (the licensee) requested the Nuclear Regulatory Commission (NRC) to authorize relief from Section XI of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) related to inspection of the inside radius sections of the Letdown Cooler nozzles over the duration of the fifth (ten-year) in-service inspection (ISi) interval.
On February 25, 2016, the NRC staff and the licensee held a clarifying discussion on the staff's draft request for additional information (RAI), transmitted via e-mail on January 7, 2016 (ADAMS Accession No. ML16008A246). Based on that discussion, the NRC staff developed this final RAI, and requests that the licensee submit written responses to the following revised questions, so that the staff can complete its review of the subject relief request.
This relief request applies to the Oconee Nuclear Station, Units 1, 2 and 3. The licensee is requesting renewal of previously granted relief requests based on the impracticality of performing inspections in the specified areas. On February 25, 2016, the NRC staff and the licensee held a clarifying discussion on the staff's draft request for additional information (RAI), transmitted via e-mail on January 7, 2016 (ADAMS Accession No. ML 16008A246).
: 1. Please provide a more detailed description of the nozzle inside radius sections that are required to be ultrasonically examined per the ASME Code, Section XI, by either referring to the drawings in the relief request as a guide or by providing additional sketches or drawings of the subject welds/nozzles.
Based on that discussion, the NRC staff developed this final RAI, and requests that the licensee submit written responses to the following revised questions, so that the staff can complete its review of the subject relief request. 1. Please provide a more detailed description of the nozzle inside radius sections that are required to be ultrasonically examined per the ASME Code, Section XI, by either referring to the drawings in the relief request as a guide or by providing additional sketches or drawings of the subject welds/nozzles.  
: 2. Section 1 of the relief request states that "... Oconee Unit 1 has two Letdown Coolers 1A and 1B. Each component has typically four B3.160 welds .... " Please confirm that the required examination is on the attachment welds of the nozzles, not the nozzles themselves, and that the required examination is on the inside radius of the welds. It appears that the nozzles are forged and are attached to the side of a pipe as a branch connection. The welds are deposited on the inside and outside circumference of the nozzles that are attaching to the pipe. Is the staff's understanding correct? If not, please clarify.
: 2. Section 1 of the relief request states that " ... Oconee Unit 1 has two Letdown Coolers 1 A and 1 B. Each component has typically four B3.160 welds .... " Please confirm that the required examination is on the attachment welds of the nozzles, not the nozzles themselves, and that the required examination is on the inside radius of the welds. It appears that the nozzles are forged and are attached to the side of a pipe as a branch connection.
: 3. Section 1 of the relief request states that, "The coolers also have operational ready spares of similar design that are rotated from spare to installed components as required Attachment
The welds are deposited on the inside and outside circumference of the nozzles that are attaching to the pipe. Is the staff's understanding correct? If not, please clarify. 3. Section 1 of the relief request states that, "The coolers also have operational ready spares of similar design that are rotated from spare to installed components as required Attachment   by maintenance
... " What is the relevance of this sentence with respect to the required examination of the subject nozzle weld inside radius sections?
: 4. Briefly describe the design and operation of the letdown coolers. Are the subject nozzles connected to the tube side or shell side of the letdown cooler? What fluids flow in the tube side and shell side of the coolers? What are the operating and design pressures and temperatures of the subject nozzles? If the fluid is not from the reactor coolant system, is the fluid being chemically treated to minimize corrosion?
: 5. Discuss how the letdown cooler and letdown system would be affected if the subject nozzles/welds fail completely (i.e., what are the consequences if the nozzle fails?). Section 4 of the relief request states that the nozzles are "set-on";
discuss the possibility of the nozzle ejecting from the pipe. Alternatively, discuss the bases for concluding that catastrophic failure of the nozzles/welds will not occur. 6. Confirm that the subject nozzles are made of 3-inch, stainless steel forging. What is the nozzle wall thickness?
What is the material of the pipe that the nozzle is attached to? What are the nominal pipe size and wall thickness of the pipe to which the nozzle is attached?
: 7. What is the weld filler material of the affected nozzles? Is the subject weld a full penetration weld, partial penetration weld, or fillet weld? 8. Has there been any leakage from or degradation of the subject nozzles/welds?
March 9, 2016 MEMORANDUM TO: Michael T. Markley, Chief Plant Licensing Branch 11-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation FROM: James R. Hall, Senior Project Manager IRA! Plant Licensing Branch 11-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation


==SUBJECT:==
by maintenance ... " What is the relevance of this sentence with respect to the required examination of the subject nozzle weld inside radius sections?
OCONEE NUCLEAR STATION, UNITS 1, 2, AND 3 -REQUEST FOR ADDITIONAL INFORMATION FOR RELIEF REQUEST 14-0N-001, LETDOWN COOLER NOZZLE WELDS (CAC NOS. MF6290, MF6291 AND MF6292) By letter dated May 4, 2015 (Agencywide Documents and Access Management System (ADAMS) Accession No. ML 15132A279), Duke Energy Carolinas, LLC, (the licensee) requested the Nuclear Regulatory Commission (NRC) to authorize relief from Section XI of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) related to inspection of the inside radius sections of the Letdown Cooler nozzles over the duration of the fifth (ten-year) in-service inspection (ISi) interval.
: 4. Briefly describe the design and operation of the letdown coolers. Are the subject nozzles connected to the tube side or shell side of the letdown cooler? What fluids flow in the tube side and shell side of the coolers? What are the operating and design pressures and temperatures of the subject nozzles? If the fluid is not from the reactor coolant system, is the fluid being chemically treated to minimize corrosion?
On February 25, 2016, the NRC staff and the licensee held a clarifying discussion on the staff's draft request for additional information (RAI), transmitted via e-mail on January 7, 2016 (ADAMS Accession No. ML 16008A246).
: 5. Discuss how the letdown cooler and letdown system would be affected if the subject nozzles/welds fail completely (i.e., what are the consequences if the nozzle fails?). Section 4 of the relief request states that the nozzles are "set-on"; discuss the possibility of the nozzle ejecting from the pipe. Alternatively, discuss the bases for concluding that catastrophic failure of the nozzles/welds will not occur.
Based on that discussion, the NRC staff developed the attached final RAI, and requested that the licensee submit written responses to the revised questions, so that the staff can complete its review of the subject relief request. Docket Nos. 50-269, 50-270, and 50-287
: 6. Confirm that the subject nozzles are made of 3-inch, stainless steel forging. What is the nozzle wall thickness? What is the material of the pipe that the nozzle is attached to? What are the nominal pipe size and wall thickness of the pipe to which the nozzle is attached?
 
: 7. What is the weld filler material of the affected nozzles? Is the subject weld a full penetration weld, partial penetration weld, or fillet weld?
==Attachment:==
: 8. Has there been any leakage from or degradation of the subject nozzles/welds?


Final RAI cc w/attachment:
ML16061A565 OFFICE:           N RR/DORL/LPL2-1 /PM         NRR/DORL/LPL2-1/LA NAME:             JRHall                       SFigueroa DATE:             3/09/2016                   3/08/2016}}
Distribution via Listserv DISTRIBUTION PUBLIC RidsNrrDorlDpr Resource RidsNrrDorlLpl2-1 Resource J. Tsao, NRR/DE/EPNB ADAMS Accession No.: ML 16061A565 OFFICE: N RR/DORL/LPL2-1  
/PM NAME: JRHall DATE: 3/09/2016 LPL2-1 R/F RidsNrrPMOconee Resource RidsNsirDprDdep Resource NRR/DORL/LPL2-1/LA SFigueroa 3/08/2016 OFFICIAL RECORD COPY}}

Latest revision as of 04:51, 19 March 2020

Request for Additional Information for Relief Request 14-ON-001, Letdown Cooler Nozzle Welds
ML16061A565
Person / Time
Site: Oconee  Duke Energy icon.png
Issue date: 03/09/2016
From: Hall J
Plant Licensing Branch II
To: Markley M
Plant Licensing Branch II
Hall J, NRR, DORL, 415-4032
References
CAC MF6290, CAC MF6291, CAC MF6292
Download: ML16061A565 (4)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 March 9, 2016 MEMORANDUM TO: Michael T. Markley, Chief Plant Licensing Branch 11-1 r

Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation 1I () n FROM: James R. Hall, Senior Project Manager Plant Licensing Branch 11-1 f' 1~

Division of Operating Reactor Licensing, Office of Nuclear Reactor Regulation

SUBJECT:

OCONEE NUCLEAR STATION, UNITS 1, 2, AND 3- REQUEST FOR ADDITIONAL INFORMATION FOR RELIEF REQUEST 14-0N-001, LETDOWN COOLER NOZZLE WELDS (CAC NOS. MF6290, MF6291 AND MF6292)

By letter dated May 4, 2015 (Agencywide Documents and Access Management System (ADAMS) Accession No. ML15132A279), Duke Energy Carolinas, LLC, (the licensee) requested the Nuclear Regulatory Commission (NRC) to authorize relief from Section XI of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) related to inspection of the inside radius sections of the Letdown Cooler nozzles over the duration of the fifth (ten-year) in-service inspection (ISi) interval.

On February 25, 2016, the NRC staff and the licensee held a clarifying discussion on the staff's draft request for additional information (RAI), transmitted via e-mail on January 7, 2016 (ADAMS Accession No. ML16008A246). Based on that discussion, the NRC staff developed the attached final RAI, and requested that the licensee submit written responses to the revised questions, so that the staff can complete its review of the subject relief request.

Docket Nos. 50-269, 50-270, and 50-287

Attachment:

Final RAI cc w/attachment: Distribution via Listserv

FINAL REQUEST FOR ADDITIONAL INFORMATION RELIEF REQUEST 14-0N-001 LETDOWN COOLER NOZZLE WELDS OCONEE NUCLEAR STATION, UNITS 1, 2 AND 3 DUKE ENERGY CAROLINAS, LLC DOCKET NOS. 50-269, 50-270 AND 50-287 By letter dated May 4, 2015 (Agencywide Documents and Access Management System (ADAMS) Accession No. ML15132A279), Duke Energy Carolinas, LLC, (the licensee) requested the Nuclear Regulatory Commission (NRC) to authorize relief from Section XI of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) related to inspection of the inside radius sections of the Letdown Cooler nozzles over the duration of the fifth (ten-year) in-service inspection (ISi) interval. This relief request applies to the Oconee Nuclear Station, Units 1, 2 and 3. The licensee is requesting renewal of previously granted relief requests based on the impracticality of performing inspections in the specified areas.

On February 25, 2016, the NRC staff and the licensee held a clarifying discussion on the staff's draft request for additional information (RAI), transmitted via e-mail on January 7, 2016 (ADAMS Accession No. ML16008A246). Based on that discussion, the NRC staff developed this final RAI, and requests that the licensee submit written responses to the following revised questions, so that the staff can complete its review of the subject relief request.

1. Please provide a more detailed description of the nozzle inside radius sections that are required to be ultrasonically examined per the ASME Code,Section XI, by either referring to the drawings in the relief request as a guide or by providing additional sketches or drawings of the subject welds/nozzles.
2. Section 1 of the relief request states that "... Oconee Unit 1 has two Letdown Coolers 1A and 1B. Each component has typically four B3.160 welds .... " Please confirm that the required examination is on the attachment welds of the nozzles, not the nozzles themselves, and that the required examination is on the inside radius of the welds. It appears that the nozzles are forged and are attached to the side of a pipe as a branch connection. The welds are deposited on the inside and outside circumference of the nozzles that are attaching to the pipe. Is the staff's understanding correct? If not, please clarify.
3. Section 1 of the relief request states that, "The coolers also have operational ready spares of similar design that are rotated from spare to installed components as required Attachment

by maintenance ... " What is the relevance of this sentence with respect to the required examination of the subject nozzle weld inside radius sections?

4. Briefly describe the design and operation of the letdown coolers. Are the subject nozzles connected to the tube side or shell side of the letdown cooler? What fluids flow in the tube side and shell side of the coolers? What are the operating and design pressures and temperatures of the subject nozzles? If the fluid is not from the reactor coolant system, is the fluid being chemically treated to minimize corrosion?
5. Discuss how the letdown cooler and letdown system would be affected if the subject nozzles/welds fail completely (i.e., what are the consequences if the nozzle fails?). Section 4 of the relief request states that the nozzles are "set-on"; discuss the possibility of the nozzle ejecting from the pipe. Alternatively, discuss the bases for concluding that catastrophic failure of the nozzles/welds will not occur.
6. Confirm that the subject nozzles are made of 3-inch, stainless steel forging. What is the nozzle wall thickness? What is the material of the pipe that the nozzle is attached to? What are the nominal pipe size and wall thickness of the pipe to which the nozzle is attached?
7. What is the weld filler material of the affected nozzles? Is the subject weld a full penetration weld, partial penetration weld, or fillet weld?
8. Has there been any leakage from or degradation of the subject nozzles/welds?

ML16061A565 OFFICE: N RR/DORL/LPL2-1 /PM NRR/DORL/LPL2-1/LA NAME: JRHall SFigueroa DATE: 3/09/2016 3/08/2016