{{#Wiki_filter:Appendix C Job Performance Measure Form ES-C-1 Worksheet Faci I ity : Ginna Task No.: 004-037-01  
{{#Wiki_filter:Appendix C                             Job Performance Measure                 Form ES-C-1 Worksheet FaciIity:           Ginna                                 Task No.:   004-037-01-01 TasWJPM
-01 TasWJPM Title: Alternate Dilution of the RCS (WB JPM No.: 2008 NRC JPM A occurs during dilution)
 
==Title:==
Alternate Dilution of the RCS (WB     JPM No.:   2008 NRC JPM A occurs during dilution)
WA  
WA  


==Reference:==
==Reference:==
004 A2.16      3.2 / 3.6 Examinee:                                              NRC Examiner:
Facility Evaluator:                                    Date:
Method of testina:
Simulated Performance:                                  Actual Performance:    X Classroom            Simulator        X    Plant Applicability: RO/SRO SUBMITTED BY:                      Ted Coe                        DATE:    6/30/08 Developer REVIEWED BY:                        Art Vest                      DATE:    6/30/08 Training Techinical Reviewer REVIEWED BY:                    Don Dettman                      DATE:    6/30/08 Operations Teclinical Reviewer APPROVED BY:                    John Elrown                      DATE:    6/30/08 Training Management Page 1 of 9


004 A2.16 3.2
Appendix C                                 Jot) Performance Measure                     Form ES-C-1 Worksheet Task Standard:             Alternate dilution is secured and all critical tasks evaluated as satisfactory.
/ 3.6 Examinee: NRC Examiner:
Required Materials:       None General  
Facility Evaluator:
Date: Method of testina: Simulated Performance: Actual Performance:
X Classroom Simulator X Plant Applicability:
RO/SRO SUBMITTED BY: Ted Coe DATE: 6/30/08 Developer REVIEWED BY: Art Vest DATE: 6/30/08 Training Techinical Reviewer REVIEWED BY: Don Dettman DATE: 6/30/08 Operations Teclinical Reviewer APPROVED BY: John Elrown DATE: 6/30/08 Training Management Page 1 of 9 Appendix C Jot) Performance Measure Worksheet Form ES-C-1 Task Standard:
Required Materials:
General  


==References:==
==References:==
S-3.1, Boron Concentration Control, Rev. 02900 S-12.4, RCS Leakage Surveillance Record Instructions, Rev.54 Handouts:                  S-3.1, Boron Concentration Control, Rev. 02900 S-12.4, RCS Leakage Surveillance Record Instructions, Rev.54, Attachment RCS iLeakage Surveillance Record Time Critical Task:        NO Validation Time:            15 minutes Alternate Path:            Yes Instructor Notes:          Have the Reactivity Binder cleaned and a copy of S-12.4, Attachment RCS Leakage Surveillance Record available for examinee.
READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task succlsssfully, the objective for this Job Performance Measure will be satisfied.
Initial Conditions:                You are the HCO.
0  I will be the CRS of the CO if you need one.
0  The plant is at 98.5% power in a normal 50/50at power lineup.
0  Attachment 1, Makeup Determinations of S-3.1, Boron Concentration Control has been completed.
Initiating Cue:            Perform an alternate dilution of 100 gallons of water at 20 gpm to maintain Tave at Tref.
Page 2 of 9


Handouts:
Appendix C                             Job Performance Measure                 Form ES-C-1 Worksheet SIMULATOR SETUP For the 2008 ILT NRC Exam load IIC # 171 or Any 100% IC (IC-19).
Time Critical Task: Validation Time: Alternate Path: Instructor Notes:
The plant in a normal 100°/o powor lineup.
Alternate dilution is secured and all critical tasks evaluated as satisfactory.
In a normal 50/50electric lineup.
None S-3.1 , Boron Concentration Control, Rev. 02900 S-12.4, RCS Leakage Surveillance Record Instructions, Rev.54 S-3.1 , Boron Concentration Control, Rev. 02900 S-12.4, RCS Leakage Surveillance Record Instructions, Rev.54, Attachment RCS iLeakage Surveillance Record NO 15 minutes Yes Have the Reactivity Binder cleaned and a copy of S-12.4, Attachment RCS Leakage Surveillance Record available for examinee.
READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task succlsssfully, the objective for this Job Performance Measure will be satisfied.
Initial Conditions:
You are the HCO. 0 I will be the CRS of the CO if you need one. 0 The plant is at 98.5% power in a normal 50/50 at power lineup.
0 Attachment 1, Makeup Determinations of S-3.1, Boron Concentration Control has been completed.
Initiating Cue: Perform an alternate dilution of 100 gallons of water at 20 gpm to maintain Tave at Tref. Page 2 of 9 Appendix C Job Performance Measure Worksheet Form ES-C SIMULATOR SETUP For the 2008 ILT NRC Exam load IIC # 171 or Any 100% IC (IC-1 9). The plant in a normal 100°/o powor lineup. In a normal 50/50 electric lineup.
RMW PUMP 1B in Pull-Stop.
RMW PUMP 1B in Pull-Stop.
Ensure Tave is slightly below Tref. Insert NIS07A, PR Channel Failure CH: N-41 failed low on Manual Trigger
Ensure Tave is slightly below Tref.
: 1. Control Rods in auto. Set RMW to BA Blender flow control valve, HCV-111 controller to 40 gpm. Page 3 of 9 Appendix C Job Performance Measure Form ES-C-1 PERF'ORMANCE INFORMATION START TIME: d = CRITICAL STEP S-3.1, Att. 4, step 1 .O ENSURE Attachment 1, Makeup Determinations, is complete.
Insert NIS07A, PR Channel Failure CH: N-41 failed low on Manual Trigger 1.
Performance Step: 1 Standard:
Control Rods in auto.
Given in the initial cue. Comment: S-3.1, Att. 4, step 2.0 and 2.1 2.0 The board operator SHALL inform the CRS (SM in the CRSS 2.1 The C:RS (SM in the CRSs absence) SHALL acknowledge performance step: 2 absence) of the intent to change core reactivity.
Set RMW to BA Blender flow control valve, HCV-111 controller to 40 gpm.
the reactivity manipulation and provide input and oversight.
Page 3 of 9
Standard:
 
Informs CRS of 100 gallons of water addition. (or something to that effect) CUE: Acknowledge report.
Appendix C                       Job Performance Measure                     Form ES-C-1 PERFORMANCE INFORMATION START TIME:
Comment: 4 Performance Step: 3 Standard:
d = CRITICAL STEP S-3.1, Att. 4, step 1.O Performance Step: 1  ENSURE Attachment 1, Makeup Determinations, is complete.
Comment: Performance Step:
Standard:             Given in the initial cue.
4 Standard:
Comment:
Comment: S-3.1 , Att,, 4, step 3.0 PLACE RIUW MODE SELECTOR control switch to ALT DIL position.
S-3.1, Att. 4, step 2.0 and 2.1 performance step: 2  2.0 The board operator SHALL inform the CRS (SM in the CRSS absence) of the intent to change core reactivity.
RMW MODE SELECTOR in ALT OIL. S-3.1, Att.
2.1 The C:RS (SM in the CRSs absence) SHALL acknowledge the reactivity manipulation and provide input and oversight.
4, step 4.0 SET RMW' TO BA BLENDER FLOW CONTROL VLV, HCV 11 1, controller to the desired flow rate.
Standard:             Informs CRS of 100 gallons of water addition. (or something to that effect)
RMW TO IBA BLENDER FLOW CONTROL VLV, HCV 11 1, controller, set to 20 gpm. Page 4 of 9 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE I N FO R MAT I ON 4 Performance Step: 5 Standard:
CUE:     Acknowledge report.
Comment: 4 Performance Step: 6 Standard:
Comment:
Comment: Performance Step: 7 Standard:
S-3.1 ,Att,,4, step 3.0 4  Performance Step: 3    PLACE RIUW MODE SELECTOR control switch to ALT DIL position.
S-3.1, AH. 4, step 5.0 SET the RMW COUNTER, YIC-111, to the quantity determined in Attachment 1, Step 2.1. RMW COUNTER, YIC-111 set to 10 0 gallons. S-3.1, Att. 4, step 6.0 PLACE RMW CONTROL control switch to START position. RMW COlNTROL switch to START and released. Red light on, Green light off. S-3.1, A#,, 4, step 7.0 VERIFY the following:
Standard:              RMW MODE SELECTOR in ALT OIL.
0 Rh4W PUMP 1A OR 1B STARTS. 0 REiACTOR MAKEUP TO VCT, AOV 1 lOC, opens. 0 RhllW TO BA BLENDER FLOW CONTROL VLV, HCV 11 1, valve throttles open to the preset flow position.
Comment:
opens. RElACTOR MAKEUP TO CHG PUMP, AOV-1 lOB, 0 RMW PUMP 1A STARTS. Red light on, Green light off. 0 AOV 11 OC, opens. Red light on, Green light off. 0 HC:V 11 1, valve throttles open to the preset flow position. ACIV-1106, opens.
S-3.1, Att. 4, step 4.0 Performance Step: 4    SET RMW TO BA BLENDER FLOW CONTROL VLV, HCV 111, controller to the desired flow rate.
Red light on, Green light off. SIM OPERATOR:
Standard:              RMW TO IBA BLENDER FLOW CONTROL VLV, HCV 111, controller, set to 20 gpm.
As soon as the student has completed verifying proper lineup Comment: insert Manual Triigger 1. Page 5 of 9 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION (Start Altlernate Path) ,/ Performance Step: 8 PLACE RMW CONTROL switch to STOP position.
Comment:
Standard: The examinee determines a Rod Block exists and per the note prior to step 6.0 immediately secures the dilution operation.
Page 4 of 9
RCAW CONTROL switch in STOP. Red light off, Green light on. CUE: Acknowledge reports.
 
CUE: Comment: HCO continue with S-3.1 Attachment 4, the CO will address the other issues. S-3.1, Att. 4, step 8.0 (End Alternate Path)
Appendix C                         Job Performance Measure                       Form ES-C-1 PERFORMANCE I NFORMATION S-3.1, AH. 4, step 5.0 4  Performance Step: 5    SET the RMW COUNTER, YIC-111, to the quantity determined in Attachment 1, Step 2.1.
WHEN dilution is complete, THEN PERFORM the following:
Standard:              RMW COUNTER, YIC-111 set to 10 0 gallons.
Comment:
S-3.1, Att. 4, step 6.0 4  Performance Step: 6      PLACE RMW CONTROL control switch to START position.
Standard:                RMW COlNTROL switch to START and released.
Red light on, Green light off.
Comment:
S-3.1, A#,, 4, step 7.0 Performance Step: 7      VERIFY the following:
0   Rh4W PUMP 1A OR 1B STARTS.
0 REiACTOR MAKEUP TO VCT, AOV 1lOC, opens.
0   RhllW TO BA BLENDER FLOW CONTROL VLV, HCV 111, valve throttles open to the preset flow position.
RElACTOR MAKEUP TO CHG PUMP, AOV-1 lOB, opens.
Standard:                    0   RMW PUMP 1A STARTS. Red light on, Green light off.
0 AOV 11OC, opens. Red light on, Green light off.
0 HC:V 111, valve throttles open to the preset flow position.
ACIV-1106, opens. Red light on, Green light off.
SIM OPERATOR: As soon as the student has completed verifying proper lineup insert Manual Triigger 1.
Comment:
Page 5 of 9
 
Appendix C                       Job Performance Measure                       Form ES-C-1 PERFORMANCE INFORMATION (Start Altlernate Path)
/, Performance Step: 8   PLACE RMW CONTROL switch to STOP position.
Standard:                     The examinee determines a Rod Block exists and per the note prior to step 6.0 immediately secures the dilution operation.
RCAW CONTROL switch in STOP.
Red light off, Green light on.
CUE:   Acknowledge reports.
CUE:   HCO continue with S-3.1 Attachment 4, the CO will address the other issues.
Comment:
S-3.1, Att. 4, step 8.0 (End Alternate Path)
/, Performance step: g  WHEN dilution is complete, THEN PERFORM the following:
8.1 F'LACE RMW MODE SELECTOR control switch to AUTO position.
8.1 F'LACE RMW MODE SELECTOR control switch to AUTO position.
8.2 PUCE RMW CONTROL switch to START position, and verify RMW control red light illuminated.
8.2 P U C E RMW CONTROL switch to START position, and verify RMW control red light illuminated.
8.3 SET RMW TO BA BLENDER FLOW CONTROL VLV, tiCV 1 1 1 , controller to the normal flow setpoint of 40 GPM. ,/ Performance step:
8.3 SET RMW TO BA BLENDER FLOW CONTROL VLV, tiCV 1 11, controller to the normal flow setpoint of 40 GPM.
g Standard:
Standard:                 8.1 RMW MODE SELECTOR control switch to AUTO position.
8.1 RMW MODE SELECTOR control switch to AUTO position.
8.2 RMW CONTROL switch in START position, Red light OII, Green light off.
8.2 RMW CONTROL switch in START position, Red light OII, Green light off. 8.3 RMW TO BA BLENDER FLOW CONTROL VLV, HCV 11 1, controller at 40 GPM. Comment: S-3.1, Att. 4, step 9.0 RECORD the amount of reactor makeup water added on S-12.4, RCS Leakage Surveillance Record Instructions, Attachment RCS Leakage Slurveillance Record.
8.3 RMW TO BA BLENDER FLOW CONTROL VLV, HCV 111, controller at 40 GPM.
Performance Step: 10 Standard:
Comment:
Amount added in gallons of water recorded on S-12.4, RCS Leakage Surveillance Record Instructions, Attachment RCS Leakage Surveillance Record. Comment: Page 6 of 9 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION S-3.1, Atto, 4, step 10.0 The board operator SHALL inform the CRS (SM in the CRSS absence) the reactivity manipulation is complete.
S-3.1, Att. 4, step 9.0 Performance Step: 10  RECORD the amount of reactor makeup water added on S-12.4, RCS Leakage Surveillance Record Instructions, Attachment RCS Leakage Slurveillance Record.
Performance Step: 11 Standard:
Standard:             Amount added in gallons of water recorded on S-12.4, RCS Leakage Surveillance Record Instructions, Attachment RCS Leakage Surveillance Record.
CUE: Acknowledge report. Comment: CRS notified that reactivity manipulation is complete.
Comment:
Terminating Cue: Evaluation on this JPM is complete. STOP TIME: TIME CRITICAL STOP TIME:
Page 6 of 9
Page 7 of 9 Appendix C Job Performance Measure Form ES-C-1 VERI FXATION OF COMPLETION  
 
~ Job Performance Measure No.: 2008 NRC JPM A Examinee's Name: Date Performed:
Appendix C                       Job Performance Measure                     Form ES-C-1 PERFORMANCE INFORMATION S-3.1, Atto,4, step 10.0 Performance Step: 11  The board operator SHALL inform the CRS (SM in the CRSS absence) the reactivity manipulation is complete.
Standard:             CRS notified that reactivity manipulation is complete.
CUE:   Acknowledge report.
Comment:
Terminating Cue:         Evaluation on this JPM is complete.
STOP TIME:                               TIME CRITICAL STOP TIME:
Page 7 of 9
 
Appendix C                       Job Performance Measure       Form ES-C-1
            ~
VERI FXATION OF COMPLETION Job Performance Measure No.: 2008 NRC JPM A Examinees Name:
Date Performed:
Facility Evaluator:
Facility Evaluator:
Number of Attempts:
Number of Attempts:
Time to Complete: Question Documentation:
Time to Complete:
Question Documentation:
Question:
Question:
Response:
 
Result: Examiner's Signature:
===Response===
UNSAT -- SAT Date: Page 8 of 9 Appendix C Job Performance Measure JPM CUE SHEET Form ES-C-1 Initial Conditions:
Result:                     SAT --          UNSAT Examiners Signature:                                   Date:
You are the HCO. I will be the CRS of the CO if you need one. The plant is at 98.5% power in a normal 50/50 at power lineup.
Page 8 of 9
 
Appendix C                         Job Performance Measure                     Form ES-C-1 JPM CUE SHEET Initial Conditions:       You are the HCO.
I will be the CRS of the CO if you need one.
The plant is at 98.5% power in a normal 50/50 at power lineup.
Attachment 1, Makeup Determinations of S-3.1, Boron Concentration Control has been completed.
Attachment 1, Makeup Determinations of S-3.1, Boron Concentration Control has been completed.
Initiating Cue: Perform an alternate dilution of 100 gallons of water at 20 gpm to maintain Tave at Tref. Page 9 of 9 Appendix C Job Performance Measure Worksheet Form ES-C-1 Facility:
Initiating Cue:     Perform an alternate dilution of 100 gallons of water at 20 gpm to maintain Tave at Tref.
Ginna Task No.: 006-01 8-05-01A TasWJPM Title: Transfer ECCS to Cold Leg JPM No.: 2008 NRC JPM B Recirculation (Alt. Path)
Page 9 of 9
 
Appendix C                             Job Performance Measure               Form ES-C-1 Worksheet Facility:           Ginna                                 Task No.:   006-018-05-01A TasWJPM
 
==Title:==
Transfer ECCS to Cold Leg             JPM No.:   2008 NRC JPM B Recirculation (Alt. Path)
WA  
WA  


==Reference:==
==Reference:==
EPE 01 1 EA1.11 4.2 / 4.2 Examinee:                                              NRC Examiner:
Facility Evaluator:                                    Date:
Method of testina:
Simulated Performance:                                  Actual Petformance:    X Classroom            Simulator      X    Plant Applicability: RO/SRO SUBMllTED BY:                        Ted Coe                      DATE:    6/30/08 Devleloper REVIEWED BY:                        Art Vest                      DATE:    6130108 Training Technical Reviewer REVIEWED BY:                    Don Dettman                      DATE:    6/30/08 Operations Technical Reviewer APPROVED BY:                    John Elrown                      DATE:    6/30/08 Training Management Page 1 Of 14


EPE 01 1 EA1.11 4.2
Appendix C                                   Job Performance Measure                 Form ES-C-1 Worksheet Task Standard:             One RHR pump running, taking suction from the Containment Wsump and all critical tasks evaluated as satisfactory.
/ 4.2 Examinee:
Required Materials:         DC power panel key.
NRC Examiner:
General  
Facility Evaluator:
Date: Method of testina: Simulated Performance: Actual Petformance:
X Classroom Simulator X Plant Applicability:
RO/SRO SUBMllTED BY: Ted Coe DATE: 6/30/08 Devleloper REVIEWED BY: Art Vest DATE: 6130108 Training Technical Reviewer REVIEWED BY: Don Dettman DATE: 6/30/08 Operations Technical Reviewer APPROVED BY: John Elrown DATE: 6/30/08 Training Management Page 1 Of 14 Appendix C Job Performance Measure Worksheet Form ES-C-1 Task Standard:
One RHR pump running, taking suction from the Containment "W sump and all critical tasks evaluated as satisfactory.
Required Materials:
DC power panel key. General  


==References:==
==References:==
ES-1.3, TRANSFER TO COLD LEG RECIRCULATION, Rev. 04200 Handouts:                  ES-1.3, TRANSFER TO COLD LEG RECIRCULATION, Rev. 04200 Time Critical Task:        NO Validation Time:            15 minutes Alternate Path:            YES Instructor Notes:          None READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
Initial Conditions:                You are the HCO.
0    Reactor trip with SI occurred.
0    The has CRS initiated loss of coolant actions 0    RWST level is at 28% and trending down slowly.
0    The Control Room crew is currently at Step 22 of E-1.
Initiating Cue:            The CRS directs you to transfer to Cold Leg Recirculation per ES-1.3, Transfer to Cold Leg Recirculation.
Page 2of 14


ES-1.3, TRANSFER TO COLD LEG RECIRCULATION, Rev. 04200 Handouts:
Appendix C                            Job Performance Measure                  Form ES-C-1 Worksheet SllllULATOR SETUP For the 2008 ILT NRC Exam load I/C: # 172 and Freeze the simulator until the operator is ready to start then go to run.
ES-1.3, TRANSFER TO COLD LEG RECIRCULATION, Rev. 04200 Time Critical Task: NO Validation Time: 15 minutes Alternate Path: YES Instructor Notes: None READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
or e  Any at power IC.
Initial Conditions:
a  Max break LOCA.
You are the HCO. 0 Reactor trip with SI occurred.
a  Insert MALF RCS03B.
0 The has CRS initiated loss of coolant actions 0 RWST level is at 28% and trending down slowly. 0 The Control Room crew is currently at Step 22 of E-1 . Initiating Cue: The CRS directs you to transfer to Cold Leg Recirculation per ES-1.3, Transfer to Cold Leg Recirculation.
a  Ensure (4) SW pumps running.
Page 2of 14 Appendix C Job Performance Measure Form ES-C-1 Worksheet - SllllULATOR SETUP For the 2008 ILT NRC Exam load I/C: # 172 and Freeze the simulator until the operator is ready to start then go to run. or e a a a a e a a a a e Any at power IC. Max break LOCA. Insert MALF RCS03B. Ensure (4) SW pumps running. Complete E-1 up to Step 19 with RWST Level > 28% (approx. 29%). Ensure both CS Pumps are running. Ensure A CCW Pump is running. Ensure B CCW Pump is secured. Insert trip CLG02B for B CCW Pump. Ensure MOV-738A and 7388 are closed. Freeze simulator until operator re'sdy to start then go to run. Page 3 of 14 Appendix C ~ ~ ~~~ ~ Job Performance Measure PER F:O RMANC E INFO R MATI 0 N ~~~ ~ Form ES-C-1 START TIME: .I = CRITICAL STEP ES-1.3, step 1 Performance Step:
a  Complete E-1 up to Step 19 with RWST Level > 28% (approx. 29%).
1 Verify RWST level - GREATER THAN 15% Standard:
e  Ensure both CS Pumps are running.
Monitors RWST Level. IF sump recirculation NOT in progress, THEN pull-stop all pumps taking suction from RWST, EXCEPT one SI pu~np AND go to ECA-1.1, LOSS OF EMERGENCY COOLANT RECIRCULATION, Step 1. Comment: ES-1.3, slep 2 Performance Step: 2 Verify CNIVlT Sump B Level - AT LEAST 113 INCHES Standard: Locates and identifies CNMT Sump B Level is at least 113 INCHES. (2) 11 3 inches Red indicator lights lit on CNMT Sump Level Indicator.
a  Ensure A CCW Pump is running.
Comment: Standard:
a  Ensure B CCW Pump is secured.
Depresses SI reset P/B. Comment: ES-1.3, step 4.a Check IF Llnnecessary Pumps Can Be Stopped: a. Three SI pumps - RUNNING Performance Step: 4 Standard : Locates and identifies A, B and C SI pumps running. Red lights on and Green lights off. Comment: IPage 4 of 14 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION ES-1.3, step 4.b ,/ Performance Step:
a  Insert trip CLG02B for B CCW Pump.
5 Stop SI plJmp C and place both switches in PULL STOP Standard:
a  Ensure MOV-738A and 7388 are closed.
Locates and identifies Bus 14 SI pump C and places switch in PULL STOP.
Freeze simulator until operator re'sdy to start then go to run.
Locates and identifies Bus 16 SI pump C and places switch in PULL STOP. Red lights; off and Green lights off. Comment: ES-1.3, step 4.c Stop both RHR pumps and place in PULL STOP 4 Performance Step: 6 Standard:
Page 3 of 14
Locates and identifies A RHR pump and places switch in PULL STOP. Locates alrld identifies B RHR pump and places switch in PULL STOP. Red lights off and Green lights off. Comment: ES-1.3, step 4.d Performance Step: 7 Both CNMT spray pumps - RUNNING Standard:
 
Locates arid identifies A and B CNMT spray pumps running. Red lights on and Green lights off. Comment: Page 5 of 14 Appendix C Jab Performance Measure Form ES-C-1 PERFORMANCE NFORMATION Standard:
                                        ~  ~  ~~~      ~                  ~~~    ~
Locates and identifies A CS pump switch and places in PULL STOP. Locates and identifies B CS pump switch and places in PULL STOP. Red light off and Green light off for secured pump. or Comment: ES-1.3, sl:ep 4.f Performance Step: 9 Check ChlMT pressure - LESS THAN 28 PSlG Standard:
Appendix C                    Job Performance Measure                  Form ES-C-1 PERF:ORMANCE INFORMATI0N START TIME:
Locates alnd identifies on PI-944, 945,947 or 949 CNMT pressure is <28 psig. Comment: ES-1.3, step 4.9 Place NaC)H Tank outlet valve switches to OPEN J Performance Step: 10 AOV-836A ACIV-8366 Standard:
.I= CRITICAL STEP ES-1.3, step 1 Performance Step: 1 Verify RWST level - GREATER THAN 15%
Locates, identifies and places NaOH Tank outlet valve switches to OPEN. 0 AOV-836A is open 0 AClV-836B is open Comment: Standard: Depresses Containment Spray reset P/B. Comment: Page 6 of 14 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION ES-1.3, step 4.i Close discharge valves for idle CNMT spray pump(s) ,/ Performance Step: 12 0 PuinpA MOV-860A MOV-8608 0 Pump B MOV-860C MOV-860D Standard:
Standard:          Monitors RWST Level. IF sump recirculation NOT in progress, THEN pull-stop all pumps taking suction from RWST, EXCEPT one SI pu~npAND go to ECA-1.1, LOSS OF EMERGENCY COOLANT RECIRCULATION, Step 1.
Locates, identifies and closes discharge valves for idle CNMT spray pump stopped in Performance Step
Comment:
: 8. or 0 Pump A MOV-860A MOV-860B - Closed Pump B MOV-860C MOV-860D - Closed Red lights off and Green lights on for closed valves. Comment: ES-1.3, step 5.a Performance Step:
ES-1.3, slep 2 Performance Step: 2 Verify CNIVlT Sump B Level - AT LEAST 113 INCHES Standard:          Locates and identifies CNMT Sump B Level is at least 113 INCHES.
13 Establish Adequate SW Flow: a. Verify at least two SW pumps - RUNNING Standard:
(2)113 inches Red indicator lights lit on CNMT Sump Level Indicator.
Locates arid identifies (4) Service Water Pumps running. Red lights on and Green lights off. Comment: ES-1.3, S~OP 5.b Verify AUX BLDG SW isolation valves - OPEN Performance Step: 14 0 MCiV-4615 and MOV-4734 0 MOV-4616 and MOV-4735 Standard:
Comment:
Locates anld identifies AUX BLDG SW isolation valves. 0 MOV-4615 and MOV-4734 - OPEN 0 MOV-4616 and MOV-4735 - OPEN Red lights on and Green lights off. Comment: ES-1.3, stc!p 5.c Performance Step:
Standard:           Depresses SI reset P/B.
15 Determine required SW flow to CCW HXs per table:
Comment:
Standard:
ES-1.3, step 4.a Performance Step: 4 Check IF Llnnecessary Pumps Can Be Stopped:
Total of 5000 gpm - 6000 gpm equally divided to both HXs. Normal SW Discharge alignment.
: a. Three SI pumps - RUNNING Standard:           Locates and identifies A, B and C SI pumps running.
Comment: Page 7 of 14 Appendix C Joo Performance Measure Form ES-C-1 PERFORMANCE INFORMATION ES-1.3, sbep 5.6 Direct A0 to adjust SW flow to required value. IF on normal SW discharge:
Red lights on and Green lights off.
,/ Performance Step: 16 V-4619, CCW HX A V-4620, CCW HX B Standard:
Comment:
Cue: Comment: Contacts A0 to adjust Normal SW flow to a Total of 5000 gpm - 6000 gpm equally divided to both CCW HXs. Normal SW flow is a of Total of 5500 gpm equally divided between both CCW HXs. ES-1.3, step 6.a ,/ Performance Step: 17 Check both CCW pumps - RUNNING Standard:
IPage 4 of 14
Locates A CCW Pump - Red light on and Green light off. Locates B CCW Pump - Red light off and Green light on. Identifies El CCW pump not running and goes to 6.a RNO Comment: ES-1.3, step 6.a.l RNO (START Alternate Path)
 
Start CCW pumps as power supply permits (1 22 kw each). Performance Step: 18 Standard:
Appendix C                    Job Performance Measure                  Form ES-C-1 PERFORMANCE INFORMATION ES-1.3, step 4.b
Locates arid starts B CCW Pump. Red light off. Green light on. White light on. Identifies El CCW pump will not start. Comment: ES-1.3, step 6.a.2 RNO ,/ Performance Step: 19 IF both CCW pumps are running, THEN go to step 6.b. Standard:
/, Performance Step: 5  Stop SI plJmp C and place both switches in PULL STOP Standard:           Locates and identifies Bus 14 SI pump C and places switch in PULL STOP.
Determine:;
Locates and identifies Bus 16 SI pump C and places switch in PULL STOP.
both CCW pumps are not running and does not go to step 6.b. Goes to RNO step 6.a.3. Comment: Page 8 of 14 Appendix C Jcb Performance Measure Form ES-C-1 PERFORMANCE INFORMATION 4 Performance Step: 20 Standard:
Red lights; off and Green lights off.
Comment: Performance Step: 21 Standard:
Comment:
ES-1.3, sl:ep 6.a.3 RNO (End Alternate Path)
ES-1.3, step 4.c 4  Performance Step: 6  Stop both RHR pumps and place in PULL STOP Standard:           Locates and identifies A RHR pump and places switch in PULL STOP.
IF only one CCW pump is running, THEN perform the following: a) Place NRHx temperature control valve TCV-130 to b) Manually open CCW MOV to only one operable RHR loop. MANUAL and close valve. Open MOV-738A Open MOV-7386 or c) Go to step 7. Places NRHx temperature control valve TCV-130 to MANLlAL and closes valve. Locates, identifies and opens only (1) CCW valve to one RHR Hx: MOV-738A - open MOV-7386 - open Red light on and Green light off for open valve. or c) Goes tcl step 7. Does not perform step 6.b. ES-1.3, step 7.a Verify RHR System Alignment:
Locates alrld identifies B RHR pump and places switch in PULL STOP.
: a. Verify the following valves - CLOSED o RHR suction valves from loop A hot leg MCIV-700 MCIV-701 o RHR discharge valves to loop 6 cold leg MC)V-720 MOV-721 Locates, identifies and verifies closed:
Red lights off and Green lights off.
MOV-700 MCIV-701 MCIV-720 MCIV-721 Red lights off and Green lights on. Comment: Page 9of 14 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION ES-1.3, step 7.b Performance Step: 22 Verify RHR pump suction crosstie valves - OPEN MOV-704A MOV-704B Standard:
Comment:
Locates, identifies and verifies open: MOV-704A MOV-704B Red lights on and Green lights off. Comment: ES-1.3, step 7.c Performance Step: 23 Verify the following valves - OPEN o RHR pump discharge to Rx vessel deluge valves MOV-852A MOV-852B o RHR sixtion from sump B (inside CNMT) MCIV-851A MCIV-851B Standard:
ES-1.3,step 4.d Performance Step: 7 Both CNMT spray pumps - RUNNING Standard:           Locates arid identifies A and B CNMT spray pumps running.
Locates, identifies and verifies open: MCIV-852A MOV-852B MCIV-851A MClV-851B Red lights on and Green lights off. Comment: ES-1.3, step 7.d Verify RCCIT pump suction valves from sump B - CLOSED Performance Step:
Red lights on and Green lights off.
24 MCIV-1813A MOV-18138 Standard:
Comment:
Locates, identifies and verifies closed: MCV-1813A MOV-18138 Red lights off and Green lights on. Comment: !>age 1Oof 14 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION 4 Performance Step: 25 Standard:
Page 5 of 14
Comment: 4 Performance Step:
 
26 Standard:
Appendix C                    Jab Performance Measure                      Form ES-C-1 PERFORMANCE NFORMATION Standard:            Locates and identifies A CS pump switch and places in PULL STOP.
ES-1.3, step 8.a Close RW ST outlet valve to RHR pump suction, MOV-856 (turn on DC power key switch) Locates, identifies and closes (turns on DC power key switch): Red light off and Green light on. MCN-856 - Closed ES-1.3, step 8.b Open both RHR suction valves from sump B (outside CNMT) MCW-850A - OPEN MCIV-8506 - OPEN Locates, identifies and opens: MC)V-850A -open 0 MCN-850B -open Red lights on and Green lights off. Comment: ES-1.3, step 8.c (START Alternate Path)
or Locates and identifies B CS pump switch and places in PULL STOP.
,/ Performance step: 27 Check MOV-738A AND MOV-7386 - BOTH OPEN Standard:
Red light off and Green light off for secured pump.
Locates, identifies and verifies: (one valve will be shut due to only having (1) CCW pump available - Performance Step
Comment:
: 17) 0 MCW738A -Open 0 MCW-7388 -Open Red light cln and Green light off for open valve Red light clff and Green light on for closed valve. Goes to step 8.c RNO since both valves are not open. Comment: Page 1 1 of 14 Appendix C Job Performance Measure Form ES-C-1 PERFiORMANCE INFORMATION ES-1.3, step 8.c RNO (End Alternate Path) 1) IF MOV-738A open, THEN start RHR Pump A and go to step 8d. 2) IF MOV-738B open, THEN start RHR Pump B and go to step 8d. ,/ Performance Step: 28 Perform the following:
ES-1.3, sl:ep4.f Performance Step: 9  Check ChlMT pressure - LESS THAN 28 PSlG Standard:           Locates alnd identifies on PI-944, 945,947 or 949 CNMT pressure is <28 psig.
Standard: Locates, identifies and starts:
Comment:
RHR Pump A if MOV-738A is open. RHR Purnp B if MOV-738B is open. Red light on and Green light off for started pump. Goes to step 8.d. Comment: ES-1.3, step 8.d Performance Step:
ES-1.3, step 4.9 J  Performance Step: 10 Place NaC)H Tank outlet valve switches to OPEN AOV-836A ACIV-8366 Standard:            Locates, identifies and places NaOH Tank outlet valve switches to OPEN.
29 Start one RHR pump - ONE RHR PUMP RUNNING Standard:
0  AOV-836A is open 0  AClV-836B is open Comment:
Locates, identifies and verifies RHR pump started in previous step is still running.
Standard:          Depresses Containment Spray reset P/B.
Red light on and Green light off for running pump. Comment: ES-1.3, step 9 Performance Step: 30 Check RWST Level - LESS THAN 15% Standard:
Comment:
CUE: Comment: Locates and determines what RWST Level is. No further action is required.
Page 6 of 14
Terminating Cue: Evaluation on this JPM is complete.
 
STOP TIME: TIME CRITICAL STOP TIME:
Appendix C                        Job Performance Measure                    Form ES-C-1 PERFORMANCE INFORMATION ES-1.3, step 4.i
Page 12 of 14 Appendix C Job Performance Measure Form ES-C-1 VERIFICATION OF COMPLETION Job Performance Measure No.: 2008 PJRC JPM B Examinee's Name: Date Performed:
/,  Performance Step: 12  Close discharge valves for idle CNMT spray pump(s) 0    PuinpA MOV-860A MOV-8608 0    Pump B MOV-860C MOV-860D Standard:            Locates, identifies and closes discharge valves for idle CNMT spray pump stopped in Performance Step 8.
0    Pump A MOV-860A MOV-860B - Closed or Pump B MOV-860C MOV-860D - Closed Red lights off and Green lights on for closed valves.
Comment:
ES-1.3, step 5.a Performance Step: 13  Establish Adequate SW Flow:
: a. Verify at least two SW pumps - RUNNING Standard:             Locates arid identifies (4) Service Water Pumps running.
Red lights on and Green lights off.
Comment:
ES-1.3, S ~ O P5.b Performance Step: 14 Verify AUX BLDG SW isolation valves - OPEN 0    MCiV-4615 and MOV-4734 0    MOV-4616 and MOV-4735 Standard:            Locates anld identifies AUX BLDG SW isolation valves.
0    MOV-4615 and MOV-4734 - OPEN 0    MOV-4616 and MOV-4735 - OPEN Red lights on and Green lights off.
Comment:
ES-1.3, stc!p 5.c Performance Step: 15 Determine required SW flow to CCW HXs per table:
Standard:           Total of 5000 gpm - 6000 gpm equally divided to both HXs.
Normal SW Discharge alignment.
Comment:
Page 7 of 14
 
Appendix C                      Joo Performance Measure                  Form ES-C-1 PERFORMANCE INFORMATION ES-1.3, sbep 5.6
,/ Performance Step: 16 Direct A 0 to adjust SW flow to required value.
IF on normal SW discharge:
V-4619, CCW HX A V-4620, CCW HX B Standard:           Contacts A0 to adjust Normal SW flow to a Total of 5000 gpm -
6000 gpm equally divided to both CCW HXs.
Cue:      Normal SW flow is a of Total of 5500 gpm equally divided between both CCW HXs.
Comment:
ES-1.3, step 6.a
/, Performance Step: 17  Check both CCW pumps - RUNNING Standard:             Locates A CCW Pump - Red light on and Green light off.
Locates B CCW Pump - Red light off and Green light on.
Identifies El CCW pump not running and goes to 6.a RNO Comment:
ES-1.3, step 6.a.l RNO (START Alternate Path)
Performance Step: 18  Start CCW pumps as power supply permits (122 kw each).
Standard:             Locates arid starts B CCW Pump.
Red light off. Green light on. White light on.
Identifies El CCW pump will not start.
Comment:
ES-1.3, step 6.a.2 RNO
/, Performance Step: 19  IF both CCW pumps are running, THEN go to step 6.b.
Standard:             Determine:; both CCW pumps are not running and does not go to step 6.b. Goes to RNO step 6.a.3.
Comment:
Page 8 of 14
 
Appendix C                      Jcb Performance Measure                      Form ES-C-1 PERFORMANCE INFORMATION ES-1.3, sl:ep 6.a.3 RNO (End Alternate Path) 4  Performance Step: 20 IF only one CCW pump is running, THEN perform the following:
a) Place NRHx temperature control valve TCV-130 to MANUAL and close valve.
b) Manually open CCW MOV to only one operable RHR loop.
Open MOV-738A or Open MOV-7386 c) Go to step 7.
Standard:                Places NRHx temperature control valve TCV-130 to MANLlAL and closes valve.
Locates, identifies and opens only (1) CCW valve to one RHR Hx:
MOV-738A - open or MOV-7386 - open Red light on and Green light off for open valve.
c) Goes tcl step 7. Does not perform step 6.b.
Comment:
ES-1.3, step 7.a Performance Step: 21 Verify RHR System Alignment:
: a. Verify the following valves - CLOSED o RHR suction valves from loop A hot leg MCIV-700 MCIV-701 o RHR discharge valves to loop 6 cold leg MC)V-720 MOV-721 Standard:            Locates, identifies and verifies closed:
MOV-700 MCIV-701 MCIV-720 MCIV-721 Red lights off and Green lights on.
Comment:
Page 9of 14
 
Appendix C                      Job Performance Measure                Form ES-C-1 PERFORMANCE INFORMATION ES-1.3, step 7.b Performance Step: 22 Verify RHR pump suction crosstie valves - OPEN MOV-704A MOV-704B Standard:            Locates, identifies and verifies open:
MOV-704A MOV-704B Red lights on and Green lights off.
Comment:
ES-1.3, step 7.c Performance Step: 23 Verify the following valves - OPEN o RHR pump discharge to Rx vessel deluge valves MOV-852A MOV-852B o RHR sixtion from sump B (inside CNMT)
MCIV-851A MCIV-851B Standard:           Locates, identifies and verifies open:
MCIV-852A MOV-852B MCIV-851A MClV-851B Red lights on and Green lights off.
Comment:
ES-1.3, step 7.d Performance Step: 24 Verify RCCIT pump suction valves from sump B - CLOSED MCIV-1813A MOV-18138 Standard:           Locates, identifies and verifies closed:
MCV-1813A MOV-18138 Red lights off and Green lights on.
Comment:
                                  !>age 1Oof 14
 
Appendix C                    Job Performance Measure                        Form ES-C-1 PERFORMANCE INFORMATION ES-1.3, step 8.a 4  Performance Step: 25 Close RW ST outlet valve to RHR pump suction, MOV-856 (turn on DC power key switch)
Standard:           Locates, identifies and closes (turns on DC power key switch):
MCN-856 - Closed Red light off and Green light on.
Comment:
ES-1.3, step 8.b 4 Performance Step: 26 Open both RHR suction valves from sump B (outside CNMT)
MCW-850A - OPEN MCIV-8506 - OPEN Standard:            Locates, identifies and opens:
MC)V-850A -open 0  MCN-850B -open Red lights on and Green lights off.
Comment:
ES-1.3, step 8.c (START Alternate Path)
/, Performance step: 27 Check MOV-738A AND MOV-7386 - BOTH OPEN Standard:            Locates, identifies and verifies: (one valve will be shut due to only having (1) CCW pump available - Performance Step 17) 0  MCW738A -Open MCW-7388 -Open Red light cln and Green light off for open valve Red light clff and Green light on for closed valve.
Goes to step 8.c RNO since both valves are not open.
Comment:
Page 11 of 14
 
Appendix C                          Job Performance Measure                    Form ES-C-1 PERFiORMANCE INFORMATION ES-1.3, step 8.c RNO (End Alternate Path)
/,   Performance Step: 28      Perform the following:
: 1) IF MOV-738A open, THEN start RHR Pump A and go to step 8d.
: 2) IF MOV-738B open, THEN start RHR Pump B and go to step 8d.
Standard:                 Locates, identifies and starts:
RHR Pump A if MOV-738A is open.
RHR Purnp B if MOV-738B is open.
Red light on and Green light off for started pump.
Goes to step 8.d.
Comment:
ES-1.3, step 8.d Performance Step: 29    Start one RHR pump - ONE RHR PUMP RUNNING Standard:                Locates, identifies and verifies RHR pump started in previous step is still running.
Red light on and Green light off for running pump.
Comment:
ES-1.3, step 9 Performance Step: 30    Check RWST Level - LESS THAN 15%
Standard:               Locates and determines what RWST Level is.
CUE:    No further action is required.
Comment:
Terminating Cue:            Evaluation on this JPM is complete.
STOP TIME:                                   TIME CRITICAL STOP TIME:
Page 12 of 14
 
Appendix C                      Job Performance Measure      Form ES-C-1 VERIFICATION OF COMPLETION Job Performance Measure No.: 2008 PJRC JPM B Examinees Name:
Date Performed:
Facility Evaluator:
Facility Evaluator:
Number of Attempts: Time to Complete:
Number of Attempts:
Time to Complete:
Question Documentation:
Question Documentation:
Question:
Question:
Response:
 
Result: UNSAT -- SAT Examiner's Signature: Date:
===Response===
Page 130f 14
Result:                     SAT            UNSAT Examiners Signature:                                   Date:
, Appendix C Job Performance Measure JPM CUE SHEET Form ES-C-1 Initial Conditions:
Page 130f 14
You are the HCO. Reactor trip with SI occurred. The has CRS initiated loss of coolant actions RWST level is at 28% and trending down slowly. The Control Room crew is currently at Step 22 of E-1 . Initiating Cue: The CRS directs you to transfer to Cold Leg Recirculation per ES-1.3, Transfer to Cold Leg Recirculation.
 
Page 14 of 14 Appendix C Job Performance Measure Worksheet Form ES-C-1 Facility:
Appendix C                       Job Performance Measure                     Form ES-C-1 JPM CUE SHEET Initial Conditions:       You are the HCO.
TasWJPM Title: WA  
Reactor trip with SI occurred.
The has CRS initiated loss of coolant actions RWST level is at 28% and trending down slowly.
The Control Room crew is currently at Step 22 of E-1.
Initiating Cue:     The CRS directs you to transfer to Cold Leg Recirculation per ES-1.3,Transfer to Cold Leg Recirculation.
Page 14 of 14
 
Appendix C                           Job Performance Measure               Form ES-C-1 Worksheet Facility:           Ginna                              Task No.:  005-001-01-01 TasWJPM
 
==Title:==
Placing LTOP on Service            JPM No.:    2008 NRC JPM C WA  


==Reference:==
==Reference:==
010 A4.03    4.0/3.8 Examinee:                                            NRC Examiner:
Facility Evaluator:                                  Date:
Method of testina:
Simulated Performance:                                Actual Performance:    X Classroom            Simulator    X    Plant Applicability: RO/SRO SUBMllTED BY:                      Ted Coe                      DATE:    6/30/08 Dewloper REVIEWED BY:                        Art Vest                    DATE:    6/30/08 Training Technical Reviewer REVIEWED BY:                    Don Dottman                    DATE:    6/30/08 Operations Technical Reviewer APPROVED BY:                    John Brown                      DATE:    6/30/08 Training Management Page 1 of 8


Examinee:
Appendix C                                 Job Performance Measure                   Form ES-C-1 Worksheet Task Standard:             Place PC-430 on service and all critical tasks evaluated as satisfactory.
Facility Evaluator:
Required Materials:       (1) Panel key for LTOP operations.
Method of testina: Ginna Task No.: 005-001 -01
-01 Placing LTOP on Service JPM No.: 2008 NRC JPM C 010 A4.03 4.0/3.8 NRC Examiner:
Date: Simulated Performance: Actual Performance:
X Classroom Simulator X Plant Applicability:
RO/SRO SUBMllTED BY: Ted Coe DATE: 6/30/08 Dew loper REVIEWED BY: Art Vest DATE: 6/30/08 Training Technical Reviewer REVIEWED BY: Don Dottman DATE: 6/30/08 Operations Technical Reviewer APPROVED BY: John Brown DATE: 6/30/08 Training Management Page 1 of 8 Appendix C Job Performance Measure Worksheet Form ES-C-1 Task Standard: Required Materials:
General  
General  


==References:==
==References:==
0-7, Alignment arid Operation of the Reactor Vessel Overpressure Protection System, Rev. 04701 0-2.2, Plant Shutdown from Hot Shutdown to Cold Conditions, Rev.
15000 Handouts:                  0-7, Alignment and Operation of the Reactor Vessel Overpressure Protection System, Rev. 04701 Time Critical Task:        NO Validation Time:            10 minutes Alternate Path:            NO Instructor Notes:          Ensure a marked up copy 0-7, Alignment and Operation of the Reactor Vessel Overpressure Protection System, Rev. 04701 is ready to give to the operator during the Initiating Cue.
READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
Initial Conditions:                You are an1 extra RO.
0  A unit shutldown is in progress.
0  The control room team is performing procedure 0-2.2, Plant Shutdown from Hot Shutdown to Cold Conditions and are at step 6.4.20 waiting for LTOP to be placed on service.
0  Section 1 tlirough section 6.1 of 0-7, Alignment and Operation of the Reactor Vessel Overpressure Protection System has been completed.
Initiating Cue:            The Shift Manager directs you to place PCV-430 on service per 0-7, Alignment and Operation of the Reactor Vessel Overpressure Protection System section 6.2!.
CUE: Hand the Operator a marked up copy of copy 0-7, Alignment and Operation of the Reactor Vessel Overpressure Protection System, Rev. 04701.
Page 2 of 8
Appendix C                          Job Performance Measure                  Form ES-C-1 Worksheet SIMULATOR SETUP For the 2008 ILT NRC Exam load I/C # 173 or Any shutting down IC where LTOP is ready to be placed on service.
Tave is between 350&deg;F and 330&deg;F.
At least (1) RCP is running.
RCS pressure is -325 psig.
Properly markup a copy of 0-7, Alignment and Operation of the Reactor Vessel Overpressure Protection System, Rev. 04701 to section 6.2.
Page 3 of 8


Handouts:
Appendix C                     Job Performance Measure                     Form ES-C-1 PERFORMANCE INFORMATION START TIME:
Time Critical Task: Validation Time: Alternate Path: Instructor Notes: Place PC-430 on service and all critical tasks evaluated as satisfactory.
.I= CRITICAL STEP 0-7, step 6.2.1 Performance Step: 1 VERIFY the following MCB Alarms extinguished:
(1) Panel key for LTOP operations.
AA-22, RCS OVER-PRESS PROTECTION TRAIN A HI PRESS AA-23, RCS OVER-PRESS PROTECTION TRAIN B HI PAESS AA-31, RCS OVER-PRESS PROTECTION TRAIN C HI PRESS Standard:           MCB Alarrns out:
0-7, Alignment arid Operation of the Reactor Vessel Overpressure Protection System, Rev. 04701 0-2.2, Plant Shutdown from Hot Shutdown to Cold Conditions, Rev. 15000 0-7, Alignment and Operation of the Reactor Vessel Overpressure Protection System, Rev.
AA-22 AA-23 AA-31 Comment:
04701 NO 10 minutes NO Ensure a marked up copy 0-7, Alignment and Operation of the Reactor Vessel Overpressure Protection System, Rev.
0-7, step 6.2.2
04701 is ready to give to the operator during the Initiating Cue. READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
/, Performance Step: 2 ENSURE ihe PRZR PORV, PCV-430 Control Switch is in the CLOSE pcisition.
Initial Conditions:
Standard:                   PCV-430 control switch is in the closed position.
You are an1 extra RO. 0 A unit shutldown is in progress.
Red light off and Green light on.
0 The control room team is performing procedure 0-2.2, Plant Shutdown from Hot Shutdown to Cold Conditions and are at step 6.4.20 waiting for LTOP to be placed on service. 0 Section 1 tlirough section 6.1 of 0-7, Alignment and Operation of the Reactor Vessel Overpressure Protection System has been completed.
Comment:
Initiating Cue: The Shift Manager directs you to place PCV-430 on service per 0-7, Alignment and Operation of the Reactor Vessel Overpressure Protection System section 6.2!. CUE: Hand the Operator a marked up copy of copy 0-7, Alignment and Operation of the Reactor Vessel Overpressure Protection System, Rev. 04701. Page 2 of 8 Appendix C Job Performance Measure Worksheet Form ES-C SIMULATOR SETUP For the 2008 ILT NRC Exam load I/C # 173 or Any shutting down IC where LTOP is ready to be placed on service. Tave is between 350&deg;F and 330&deg;F. At least (1) RCP is running. RCS pressure is -325 psig. Properly markup a copy of 0-7, Alignment and Operation of the Reactor Vessel Overpressure Protection System, Rev. 04701 to section 6.2. Page 3 of 8 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION START TIME: .I = CRITICAL STEP 0-7, step 6.2.1 VERIFY the following MCB Alarms extinguished:
0-7, step 6.2.3 4 Pedormance step: 3 OPEN ACCUM TO SURGE TANK VLV SOV-8616A. (MCB Rear)
Performance Step: 1 AA-22, RCS OVER-PRESS PROTECTION TRAIN A HI AA-23, RCS OVER-PRESS PROTECTION TRAIN B HI AA-31, RCS OVER-PRESS PROTECTION TRAIN C HI PRESS PAESS PRESS Standard:
Standard:                   Gets proper key from CRS desk.
MCB Alarrns out: AA-22 AA-23 AA-31 Comment: 0-7, step 6.2.2 ,/ Performance Step: 2 ENSURE ihe PRZR PORV, PCV-430 Control Switch is in the CLOSE pcisition.
SOV-8616A open.
Standard: PCV-430 control switch is in the closed position.
Comment:
Red light off and Green light on. Comment: 0-7, step 6.2.3 4 Pedormance step:
Page 4 of 8
3 OPEN ACCUM TO SURGE TANK VLV SOV-8616A. (MCB Rear) Standard: Gets proper key from CRS desk. SOV-8616A open. Comment: Page 4 of 8 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION 4 Performance Step: 4 Standard:
 
Comment: Performance Step: 5 Standard:
Appendix C                     Job Performance Measure                     Form ES-C-1 PERFORMANCE INFORMATION 0-7, step 6.2.4 4  Performance Step: 4 ENSURE N2 ARMING VLV SOV-8619A is in the ARM position.
Comment: Performance Step: 6
(MCB Rear)
~ Standard:
Standard:                  Uses proper key.
Comment: Performance Step: 7 Standard:
SOV-8619A is in ARM.
Comment: 0-7, step 6.2.4 ENSURE N2 ARMING VLV SOV-8619A is in the ARM position. (MCB Rear) Uses proper key. SOV-8619A is in ARM. 0-7, step 6.2.5 VERIFY CLOSED PRZR PORV, PCV-430. 0 PC:V-430 control switch is in the closed position.
Comment:
Red light off and Green light on. 0-7, step 6.2.6 RECORD pressure indicated on OP ACCUM A N2 PRESSURE, PI-455. (MCB Rear) Pressure recorded as shown on PI-455. 0-7, step 6.2.7 IF Accumulator A pressure is NOT between 735 and 760 psig, THEN CHARGE the accumulator as PER S-29.2, Charging the Reactor Vessel Overpressure Protection System Accumulators with N2. IF Accumulator A pressure is correct, THEN MARK this Step N/A. 0 Checks Accumulator A pressure is between 735 and 760 psig. 0 charging is not required.
0-7, step 6.2.5 Performance Step: 5 VERIFY CLOSED PRZR PORV, PCV-430.
0 Marks step N/A. Page 5 of 8 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION 0-7, step 6.2.8 ENSURE CLOSED MOV 51 6 breaker, MCC C position 6C, VLV- 516 RCS. Performance Step: 8 Standard:
Standard:                0 PC:V-430 control switch is in the closed position.
CUE: Acknowledge request. REPORT: Calls A0 to verify MOV 51 6 breaker is closed MOV 516 breaker, MCC C position 6C is closed. Comment: Performance Step: 9 Standard:
Red light off and Green light on.
Comment: Performance Step: 10 Standard:
Comment:
Comment: Performance Step: 11 Standard:
0-7, step 6.2.6 Performance Step: 6  RECORD pressure indicated on OP ACCUM A N2 PRESSURE, PI-455.(MCB Rear)
0-7, step 6.2.9 ENSURE OPEN PRZR PORV BLOCK VLV, MOV 516. MOV 516, PRZR POW BLOCK VLV is open. Red light on and Green light off. 0-7, step 6.2.10 RECORD the time Train A Overpressure Protection System is operable.
  ~ Standard:            Pressure recorded as shown on PI-455.
Records current time. Reports PCV-430 is on service. Reports PCV-430 is on service. CUE: Acknowledge report. Comment: Terminating Cue: Evaluation on this JPM is complete.
Comment:
STOP TIME: TIME CRITICAL STOP TIME: Page 6 of 8 Appendix C Job Performance Measure Form ES-C-1 VERIFICATION OF COMPLETION Job Performance Measure No.: 2008 NRC JPM C Examinee's Name:
0-7, step 6.2.7 Performance Step: 7  IF Accumulator A pressure is NOT between 735 and 760 psig, THEN CHARGE the accumulator as PER S-29.2, Charging the Reactor Vessel Overpressure Protection System Accumulators with N2.
Date Performed: Facility Evaluator:
IF Accumulator A pressure is correct, THEN MARK this Step N/A.
Number of Attempts: Time to Complete: Question Documentation:
Standard:                0 Checks Accumulator A pressure is between 735 and 760 psig.
0 charging is not required.
0   Marks step N/A.
Comment:
Page 5 of 8
 
Appendix C                     Job Performance Measure               Form ES-C-1 PERFORMANCE INFORMATION 0-7, step 6.2.8 Performance Step: 8  ENSURE CLOSED MOV 516 breaker, MCC C position 6C, VLV-516 RCS.
Standard:           Calls A 0 to verify MOV 516 breaker is closed CUE: Acknowledge request.
REPORT: MOV 516 breaker, MCC C position 6C is closed.
Comment:
0-7, step 6.2.9 Performance Step: 9  ENSURE OPEN PRZR PORV BLOCK VLV, MOV 516.
Standard:                    MOV 516, PRZR P O W BLOCK VLV is open.
Red light on and Green light off.
Comment:
0-7, step 6.2.10 Performance Step: 10 RECORD the time Train A Overpressure Protection System is operable.
Standard:            Records current time.
Comment:
Performance Step: 11 Reports PCV-430 is on service.
Standard:            Reports PCV-430 is on service.
CUE: Acknowledge report.
Comment:
Terminating Cue:       Evaluation on this JPM is complete.
STOP TIME:                               TIME CRITICAL STOP TIME:
Page 6 of 8
 
Appendix C                       Job Performance Measure       Form ES-C-1 VERIFICATION OF COMPLETION Job Performance Measure No.: 2008 NRC JPM C Examinees Name:
Date Performed:
Facility Evaluator:
Number of Attempts:
Time to Complete:
Question Documentation:
Question:
Question:
Response:
 
Result: UNSAT -- SAT Examiner's Signature:
===Response===
Date: Page 7 of 8 Appendix C Jclb Performance Measure JPM CUE SHEET initial Conditions:
Result:                     SAT              UNSAT Examiners Signature:                                   Date:
You are an extra RO. A unit shutdown is in progress.
Page 7 of 8
 
Appendix C                       Jclb Performance Measure JPM CUE SHEET initial Conditions:       You are an extra RO.
A unit shutdown is in progress.
0 The control room team is performing procedure 0-2.2, Plant Shutdown from Hot Shutdown to Cold Conditions and are at step 6.4.20 waiting for LTOP to be placed on service.
0 The control room team is performing procedure 0-2.2, Plant Shutdown from Hot Shutdown to Cold Conditions and are at step 6.4.20 waiting for LTOP to be placed on service.
Section 1 through section 6.1 of 0-7, Alignment and Operation of the Reactor Vessel Overpressure Protection System has been completed.
0 Section 1 through section 6.1 of 0-7, Alignment and Operation of the Reactor Vessel Overpressure Protection System has been completed.
0 Initiating Cue: The Shift Manager directs you to place PCV-430 on service per 0-7, Alignment and Operation of the Reactor Vessel Overpressure Protection System section 6.2. Page 8 of 8 Appendix C Jol) Performance Measure Worksheet Form ES-C-1 Facility:
Initiating Cue:     The Shift Manager directs you to place PCV-430 on service per 0-7, Alignment and Operation of the Reactor Vessel Overpressure Protection System section 6.2.
Ginna Task No.: 344-068-05-02 Task/JPM Title: Respond To a Control Room JPM No.: 2008 NRC JPM D Evacuation WA  
Page 8 of 8
 
Appendix C                         Jol) Performance Measure               Form ES-C-1 Worksheet Facility:           Ginna                               Task No.:   344-068-05-02 Task/JPM
 
==Title:==
Respond To a Control Room           JPM No.:   2008 NRC JPM D Evacuation WA  


==Reference:==
==Reference:==
APE 068 AA1.23      4.3 / 4.4 Examinee:                                            NRC Examiner:
Facility Evaluator:                                  Date:
Method of testina:
Simulated Performance:                              Actual Performance:    X Classroom          Simulator        X  Plant Applicability: RO/SRO SUBMITTED BY:                    Ted Coe                      DATE:    6/30/08 Developer REVIEWED BY:                      Art Vest                      DATE:    6/30/08 Training Techriical Reviewer REVIEWED BY:                    Don Dettman                    DATE:    6/30/08 Operations Technical Reviewer APPROVED BY:                  John Brown                      DATE:    6/30/08 Training Management Page 1 of 8


APE 068 AA1.23 4.3 / 4.4 NRC Examiner:
Appendix C                                   Job Performance Measure                   Form ES-C-1 Worksheet Task Standard:             Immediate actions of AP-CR.1 completed from memory and all critical tasks evaluated as satisfactory.
Date: Examinee:
Required Materials:         None General  
Facility Evaluator:
Method of testina: Simulated Performance: Actual Performance:
X Classroom Simulator X Plant Applicability:
RO/SRO SUBMITTED BY: Ted Coe DATE: 6/30/08 Developer REVIEWED BY: Art Vest DATE: 6/30/08 Training Tech riical Reviewer REVIEWED BY: Don Dettman DATE: 6/30/08 Operations Technical Reviewer APPROVED BY: John Brown DATE: 6/30/08 Training Management Page 1 of 8 Appendix C Job Performance Measure Worksheet Form ES-C-1 Task Standard: Immediate actions of AP-CR.1 completed from memory and all critical tasks evaluated as satisfactory.
Required Materials: None General  


==References:==
==References:==
AP-CR. 1, CONTROL ROOM INACCESSIBILITY, Rev.24 Handouts:                  AP-CR.1, CONTROL ROOM INACCESSIBILITY, Rev.24 Time Critical Task:        NO Validation Time:            5 minutes Alternate Path:            Yes Instructor Notes:            Evaluator will act as the CRS for the initiating cue.
READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
Initial Conditions:                You are the HCO.
0  The CO arid the SM are in the Relay Room investigating an issue.
0  I will be thtt CRS if you need one.
0  The plant is at 100% power in a normal 50/50at power lineup.
Initiating Cue:              You have the watch.
Page 2 of 8


AP-CR. 1, CONTROL ROOM INACCESSIBILITY, Rev.24 Handouts:
Appendix C                             J o l ~Performance Measure Form ES-C-1 Worksheet SIMULATOR SETUP For the 2008 ILT NRC Exam load I/C # 174 or Any 100% IC (IC-19).
AP-CR.1, CONTROL ROOM INACCESSIBILITY, Rev.24 Time Critical Task: NO Validation Time: 5 minutes Alternate Path: Yes Instructor Notes: Evaluator will act as the CRS for the initiating cue. READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
0 The plant in a normal 100% power lineup.
Initial Conditions:
In a normal 50/50 electric lineup.
You are the HCO. 0 The CO arid the SM are in the Relay Room investigating an issue. 0 I will be thtt CRS if you need one. 0 The plant is at 100% power in a normal 50/50 at power lineup. Initiating Cue: You have the watch. Page 2 of 8 Appendix C Jol~ Performance Measure Worksheet Form ES-C SIMULATOR SETUP For the 2008 ILT NRC Exam load I/C # 174 or Any 100% IC (IC-19). 0 The plant in a normal 100% power lineup.
Insert TUR02, Turbine failure to Auto trip.
In a normal 50/50 electric lineup. Insert TUR02, Turbine failure to Auto trip. Insert TUR17A, Turbine Stop Valve: VLV 3545.
Insert TUR17A, Turbine Stop Valve: VLV 3545.
0 Insert TUR178, Turbine Stop Valve: VLV 3544. 0 Insert RPS05A, Reactor trip A breaker failure. 0 Insert RPS05B, Reactor trip B breaker failure. A-RPS12 0 TURB12A,B,C,D A-ROD05 Page 3 of 8 Appendix C Jot) Pertormance Measure Form ES-C-1 PERFORMANCE INFORMATION START TIME: 4 = CRITICAL STEP To Evaluator:
0   Insert TUR178, Turbine Stop Valve: VLV 3544.
All Operator actions shall be from memory, without the aid of the procedure.
0   Insert RPS05A, Reactor trip A breaker failure.
CRS Initiating Cue: Status update, Ready. (wait for response)
0   Insert RPS05B, Reactor trip B breaker failure.
I have just been informed there are poisonoiis fumes coming up from the Relay Room. Entering AP-CR.1, CONTROL ROOM INACCESSIBILITY.
A-RPS12 0   TURB12A,B,C,D A-ROD05 Page 3 of 8
End of Update.
 
HCO. (wait for re:sponse, if required) Perform immediate operator actions for AP-CR.1. (wait for response)
Appendix C                         Jot) Pertormance Measure                       Form ES-C-1 PERFORMANCE INFORMATION START TIME:
That's correct. AP-CR.1, step 1 (Start Alternate Path)
4 = CRITICAL STEP To Evaluator: All Operator actions shall be from memory, without the aid of the procedure.
Verify Reactor Trip:
CRS Initiating Cue: Status update, Ready. (wait for response) I have just been informed there are poisonoiis fumes coming up from the Relay Room. Entering AP-CR.1, CONTROL ROOM INACCESSIBILITY. End of Update.
Performance Step: 1 At least one train of reactor trip breakers - OPEN. NelJtron flux - LOWERING. MRPl indicates - ALL CONTROL AND SHUTDOWN RODS ON BOTTOM. Standard: Reactor is not tripped. No reactor trip breakers are OPEN. NelJtron flux at 100%. MRPl indicates ALL CONTROL AND SHUTDOWN RODS are still at normal positions.
HCO. (wait for re:sponse, if required) Perform immediate operator actions for AP-CR.1. (wait for response) Thats correct.
Goes to step 1 RNO. Comment: AP-CR.l, step 1 RNO Manually trip reactor. Performance Step: 2 Standard: Depresses Reactor Trip Pushbutton Reactor is not tripped. No reactor trip breakers are OPEN. Neutron flux at 100%. MRPl indicates ALL CONTROL AND SHUTDOWN RODS are still at normal positions.
AP-CR.1, step 1 (Start Alternate Path)
Goes to RtJO step 1 .a. Comment: Page 4 of 8 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION 4 Performance Step:
PerformanceStep: 1        Verify Reactor Trip:
3 Standard:
At least one train of reactor trip breakers - OPEN.
Comment: Performance Step:
NelJtron flux - LOWERING.
4 Standard:
MRPl indicates - ALL CONTROL AND SHUTDOWN RODS ON BOTTOM.
AP-CR.1, steps 1.a thru 1.d RNO IF reactor trip breakers NOT open, THEN perform the following:
Standard:               Reactor is not tripped.
No reactor trip breakers are OPEN.
NelJtron flux at 100%.
MRPl indicates ALL CONTROL AND SHUTDOWN RODS are still at normal positions.
Goes to step 1 RNO.
Comment:
AP-CR.l, step 1 RNO Performance Step: 2      Manually trip reactor.
Standard:               Depresses Reactor Trip Pushbutton Reactor is not tripped.
No reactor trip breakers are OPEN.
Neutron flux at 100%.
MRPl indicates ALL CONTROL AND SHUTDOWN RODS are still at normal positions.
Goes to RtJO step 1.a.
Comment:
Page 4 of 8
 
Appendix C                     Job Performance Measure                     Form ES-C-1 PERFORMANCE INFORMATION AP-CR.1, steps 1.a thru 1.d RNO 4  Performance Step: 3 IF reactor trip breakers NOT open, THEN perform the following:
: a. Open Bus 13 and Bus 15 normal feed breakers.
: a. Open Bus 13 and Bus 15 normal feed breakers.
: b. Verify rod drive MG sets tripped. c. Close Bus 13 and Bus 15 normal feed breakers.
: b. Verify rod drive MG sets tripped.
: c. Close Bus 13 and Bus 15 normal feed breakers.
: d. Reset lighting breakers.
: d. Reset lighting breakers.
IF the Rx can NOT be tripped from the Control Room, THEN dispatch personnel to locally open the reactor trip breakers.
IF the Rx can NOT be tripped from the Control Room, THEN dispatch personnel to locally open the reactor trip breakers.
: a. Opens f3us 13 and Bus 15 normal feed breakers. b. Rod drive MG sets tripped. c. Closes 13us 13 and Bus 15 normal feed breakers.
Standard:           a. Opens f3us 13 and Bus 15 normal feed breakers.
: d. Resets lighting breakers by depressing Bus 13 and 15 Lighting (ONLY a, 13 and c are critical steps. Step d is NOT a critical step.) 0 0 Red lights off and Green lights on. Rod Drive MG set A and B Red lights off and Green lights on. Red lights on and Green lights off. 0 Breaker green Pushbuttons.
0  Red lights off and Green lights on.
AP-CR.1, step 2 Verify Turbine Stop Valves - CLOSED On EHC v(alve status panel. SVL Open red light on and SVR Open red light on. Identifies Turbine stop valves are still open and goes to step 2 RNO. Comment: Page 5 of 8 Appendix C Jot) Pertormance Measure Form ES-C-1 PERFORMANCE INFORMATION AP-CR.1, step 2 RNO (End Alternate Path) Manually trip turbine. IF turbine can NOT be tripped, THEN close both MSIVs. Performance Step: 5 Standard:
: b. Rod drive MG sets tripped.
Depresses Turbine Emergency Trip P/B - Turbine Does not Trip. Closes A hSSIV and B MSlV 0 Handswitch MSlV A, AOV-3517 to close. Handswitch MSlV 6, AOV-3516 to close. Red lights off and Green lights on. (Critical Stlsps are closing A and B MSIVs.) Comment: Completicm of Immediate Operator Actions CRS, lmmiediate Operator Actions for AP-CR.1 are complete. Performance Step:
0  Rod Drive MG set A and B Red lights off and Green lights on.
6 Standard:
: c. Closes 13us 13 and Bus 15 normal feed breakers.
CUE: Acknowledge report. CUE: Comment: Informs CF3S that, Immediate Operator Actions for AP-CR.1 are complete.
0  Red lights on and Green lights off.
No further actions are required.
: d. Resets lighting breakers by depressing Bus 13 and 15 Lighting Breaker green Pushbuttons.
Terminating Cue: Evaluation on this JPM is complete.
(ONLY a, 13 and c are critical steps. Step d is NOT a critical step.)
STOP TIME: TIME CRITICAL STOP TIME: Page 6 of 8 Appendix C Job Performance Measure Form ES-C-1 VERIFICATION OF COMPLETION Job Performance Measure No.: 2008 t4RC JPM D Examinee's Name: Date Performed:
Comment:
AP-CR.1, step 2 Performance Step: 4 Verify Turbine Stop Valves - CLOSED Standard:          On EHC v(alvestatus panel. SVL Open red light on and SVR Open red light on.
Identifies Turbine stop valves are still open and goes to step 2 RNO.
Comment:
Page 5 of 8
 
Appendix C                         Jot) Pertormance Measure                   Form ES-C-1 PERFORMANCE INFORMATION AP-CR.1, step 2 RNO (End Alternate Path)
Performance Step: 5      Manually trip turbine. IF turbine can NOT be tripped, THEN close both MSIVs.
Standard:               Depresses Turbine Emergency Trip P/B - Turbine Does not Trip.
Closes A hSSIV and B MSlV 0   Handswitch MSlV A, AOV-3517 to close.
Handswitch MSlV 6, AOV-3516 to close.
Red lights off and Green lights on.
(Critical Stlsps are closing A and B MSIVs.)
Comment:
Completicm of Immediate Operator Actions Performance Step: 6      CRS, lmmiediate Operator Actions for AP-CR.1 are complete.
Standard:               Informs CF3S that, Immediate Operator Actions for AP-CR.1 are complete.
CUE:    Acknowledge report.
CUE:    No further actions are required.
Comment:
Terminating Cue:           Evaluation on this JPM is complete.
STOP TIME:                                   TIME CRITICAL STOP TIME:
Page 6 of 8
 
Appendix C                     Job Performance Measure       Form ES-C-1 VERIFICATION OF COMPLETION Job Performance Measure No.: 2008 t4RC JPM D Examinees Name:
Date Performed:
Facility Evaluator:
Facility Evaluator:
Number of Attempts:
Number of Attempts:
Line 285: Line 553:
Question Documentation:
Question Documentation:
Question:
Question:
Response:
 
Result: UNSAT -- SAT Examiner's Signature:
===Response===
Date: Page 7 of 8 Appendix C Job Performance Measure JPM CUE SHEET Form ES-C-1 Initial Conditions:
Result:                     SAT --           UNSAT Examiners Signature:                                 Date:
0 You are the HCO. 0 The CO arid the SM are in the Relay Room investigating an issue. 0 I will be the CRS if you need one. The plant is at 100% power in a normal 50/50 at power lineup. Initiating Cue: You have the watch. Page 8 of 8 Appendix C Job Performance Measure Worksheet Form ES-C-1 Faci I ity : Task/JPM Title: WA  
Page 7 of 8
 
Appendix C                         Job Performance Measure                 Form ES-C-1 JPM CUE SHEET Initial Conditions:   0 You are the HCO.
0 The CO arid the SM are in the Relay Room investigating an issue.
0 I will be the CRS if you need one.
The plant is at 100% power in a normal 50/50at power lineup.
Initiating Cue:     You have the watch.
Page 8 of 8
 
Appendix C                         Job Performance Measure                 Form ES-C-1 Worksheet FaciIity:           Ginna                              Task No.:  076-004-05-01 Task/JPM
 
==Title:==
Respond to a Total ,Lossof SW      JPM No.:    2008 NRC JPM E WA  


==Reference:==
==Reference:==
076 A2.01    3.5*/3.7*
Examinee:                                            NRC Examiner:
Facility Evaluator:                                  Date:
Method of testina:
Simulated Performance:                              Actual Performance:    X Classroom          Simulator      X    Plant Applicability: RO/SRO SUBMllTED BY:                      Ted Coe                      DATE:    6/30/08 Developer REVIEWED BY:                      Art Vest                      DATE:    6/30/08 Training Technical Reviewer REVIEWED BY:                    Don Dettman                    DATE:    6/30/08 Operations Technical Reviewer APPROVED BY:                    John Brown                      DATE:    6/30/08 Training Management Page 1 of 8


Examinee: Facility Evaluator:
Appendix C                                     Job Performance Measure                   Form ES-C-1 Worksheet Task Standard:               E-0 immediate actions performed, RCPs tripped, Letdown isolated and all critical tasks evaluated as satisfactory.
Method of testina: Ginna Task No.: 076-004-05-01 Respond to a Total ,Loss of SW 076 A2.01 3.5*/ 3.7* JPM No.: 2008 NRC JPM E NRC Examiner:
Required Materials:         None General  
Date: Simulated Performance:
Actual Performance:
X Classroom Simulator X Plant Applicability:
RO/SRO SUBMllTED BY: Ted Coe DATE: 6/30/08 Developer REVIEWED BY: Art Vest DATE: 6/30/08 Training Technical Reviewer REVIEWED BY: Don Dettman DATE: 6/30/08 Operations Technical Reviewer APPROVED BY: John Brown DATE: 6/30/08 Training Management Page 1 of 8 Appendix C Job Performance Measure Form ES-C-1 Worksheet Task Standard:
Required Materials:
General  


==References:==
==References:==
AP-SW.2, LOSS OF SERVICE WATER, Rev. 00801 E-0, REACTOR TRIP OR SAFETY INJECTION, Rev. 04100 Handouts:                    AP-SW.2, LOSS OF SERVICE WATER, Rev. 00801 Time Critical Task:          NO Validation Time:            10 minutes Alternate Path:              YES Instructor Notes:            Ensure a copy of AP-SW.2, LOSS OF SERVICE WATER, Rev.
00801 is ready to give to the operator during the Initiating Cue.
READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
Initial Conditions:              You are the CO.
0    I will be the CRS if you need one.
0    The plant is at 100% power in a normal 50/50electrical lineup.
0    The running Service Water pumps have just tripped.
Initiating Cue:            The CRS directs you to perform AP-SW.2, LOSS OF SERVICE WATER.
CUE: Hand the Operator a copy AP-SIN.2, LOSS OF SERVICE WATER, Rev. 00801.
Page 2 of 8


Handouts:
Appendix C                             Job Performance Measure           Form ES-C-1 Worksheet SIMIULATOR SETUP For the 2008 ILT NRC Exam load I/C # 175 or Any 100%   IC (IC-19).
Time Critical Task: Validation Time: Alternate Path: Instructor Notes: E-0 immediate actions performed, RCPs tripped, Letdown isolated and all critical tasks evaluated as satisfactory.
The plant in a normal 100% power lineup.
None AP-SW.2, LOSS OF SERVICE WATER, Rev.
In a normal 50/50 electric lineup.
00801 E-0, REACTOR TRIP OR SAFETY INJECTION, Rev. 04100 AP-SW.2, LOSS OF SERVICE WATER, Rev.
Ensure A and C Service Water pumps are running.
00801 NO 10 minutes YES Ensure a copy of AP-SW.2, LOSS OF SERVICE WATER, Rev.
Insert CLGO1A, CLGO1B, CLGOlC and CLGO1D.
00801 is ready to give to the operator during the Initiating Cue. READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
Ensure A and C Service Water pumps are tripped and no other SW pumps are running.
Initial Conditions:
Freeze simulator and wait until the examinee takes the watch.
You are the CO. 0 0 0 I will be the CRS if you need one. The plant is at 100% power in a normal 50/50 electrical lineup. The running Service Water pumps have just tripped. Initiating Cue: The CRS directs you to perform AP-SW.2, LOSS OF SERVICE WATER. CUE: Hand the Operator a copy AP-SIN.2, LOSS OF SERVICE WATER, Rev. 00801. Page 2 of 8 Appendix C Job Performance Measure Worksheet Form ES-C SIMIULATOR SETUP For the 2008 ILT NRC Exam load I/C # 175 or Any 100% IC (IC-19). The plant in a normal 100% power lineup. In a normal 50/50 electric lineup. Ensure A and C Service Water pumps are running. Insert CLGO1 A, CLGO1 B, CLGOlC and CLGO1 D. Ensure A and C Service Water pumps are tripped and no other SW pumps are running. Freeze simulator and wait until the examinee takes the watch. Page 3 of 8 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION START TIME: d = CRITICAL STEP Performance Step: 1 Standard:
Page 3 of 8
Comment: Performance Step: 2 Standard:
 
AP-SW.2, step 1 Verify 480V AC Emergency Busses 17 and 18 - ENERGIZED.
Appendix C                     Job Performance Measure                       Form ES-C-1 PERFORMANCE INFORMATION START TIME:
Busses 17 and 18 voltage meters read  
d = CRITICAL STEP AP-SW.2, step 1 Performance Step: 1  Verify 480V AC Emergency Busses 17 and 18 - ENERGIZED.
-480 volts. Normal feeds to Bus 17 and 18 are closed. Red lights on and Green lights off. AP-SW.2, step 2a Verify SW Pump Alignment:
Standard:                    Busses 17 and 18 voltage meters read -480 volts.
Normal feeds to Bus 17 and 18 are closed.
Red lights on and Green lights off.
Comment:
AP-SW.2, step 2a Performance Step: 2  Verify SW Pump Alignment:
Check at least one SW pump running in each loop:
Check at least one SW pump running in each loop:
A or B pump in loop A. 0 C or D pump in loop 8. A and C SW Pumps Tripped (given in initial cue). 0 B a.nd D SW Pumps not running. Red lights off and Green lights on. Recognizes no Service Water pumps running. Go'es to step 2a RNO. CUE: Acknowledge any report. Comment: AP-SW.2, step 2.a.l RNO (Start Alternate Path) . Performance Step: 3 a. Perform the following:
A or B pump in loop A.
: 1) Manually start SW pumps as necessary (257 kw each). Standard:
0 C or D pump in loop 8.
0 Attctmpt to start B and D SW Pumps by taking associated control switches to Start. 0 Recognizes B and D SW Pumps trip. 0 Red lights off, White lights on and Green lights on. May report SW pump trips to the CRS. CUE: Acknowledge any reporl:. Comment: Page 4 of 8 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION AP-SW.2, step 2.a.2 RNO IF adequate cooling can NOT be supplied to a running D/G, THEN perform the following:
Standard:                    A and C SW Pumps Tripped (given in initial cue).
a) Pull stop affected D/G. b) Immediately depress voltage shutdown pushbutton.
0   B a.nd D SW Pumps not running. Red lights off and Green lights on.
Performance Step: 4 Standard:
Recognizes no Service Water pumps running.
D/G A and B voltmeters read "0 volts". - Recognizes no Diesel Generators are running and performs no actions. CUE: Acknowledge any report. Comment: AP-SW.2, step 2.a.3.a RNO IF no SW pumps can be operated, THEN perform the following:  
Go'esto step 2a RNO.
,/ Performance Step: 5 a) Trip the reactor. Standard:
CUE:     Acknowledge any report.
CUE: Acknowledge any report. Comment: Depresses Reactor Emergency Trip Pushbutton.
Comment:
AP-SW.2, step 2.a.3.b RNO ,/ Performance Step: 6 WHEN all E-0 Immediate Actions done, THEN trip BOTH RCPS. Standard:
AP-SW.2, step 2.a.l RNO (Start Alternate Path)           .
E-0 Immediate Actions: (these actions performed from memory) 1. Verify Reactor Trip - Neutron flux lowering, at least one train of Reactor trip breakers open and MRPl indicates all rods are on the bottom. 2. Verifies Turbine is tripped - Turbine Stop valves are closed as indicated on EHC valve status panel. SVL Closed Green light on and SVR Closed Green light on. 3. Verify Both Trains of AC Emergency Busses energized to at least 420 volts: Busses 14,16,17 and 18 - Volt meters for Busses 14,16, 17 and 18 all read -480 VAC. 4. Check if SI is Actuated:
Performance Step: 3   a. Perform the following:
Any SI Annunciator - LIT - Annunciators D-19, 21 , 22 and 28 extinguished and no indications that an SI is required.
: 1) Manually start SW pumps as necessary (257 kw each).
Trir, both ACPs: 1. A RCF' H/S to Stop - Red light off and Green light on. 2. B RCP' H/S to Stop - Red light off and Green light on. (Critical steps are to trip both RCPs.) CUE: Acknowledge any report. Comment: Page 5 of 8 I Jol~ Performance Measure Form ES-C-1 Appendix C PERFORMANCE INFORMATION AP-SW.2, step 2.a.3.c RNO 4 Performance Step: 7 Close letdown isol, AOV-427.
Standard:                 0 Attctmpt to start B and D SW Pumps by taking associated control switches to Start.
Standard:
0   Recognizes B and D SW Pumps trip.
ACW-427 switch in Closed. CUE: Acknowledge any report. Comment: Red light off and Green light on. AP-SW.2, step 2.a.3.d RNO (End Alternate Path)
0   Red lights off, White lights on and Green lights on.
Performance Step: 8 Close excess letdown, HCV-123.
May report SW pump trips to the CRS.
Standard:
CUE:     Acknowledge any reporl:.
CUE: Acknowledge any report. CUE: Comment: HCV-123 is at 0% demand. No further action is required.
Comment:
Terminating Cue: Evaluation on this JPM is complete.
Page 4 of 8
STOP TIME: TIME CRITICAL STOP TIME:
 
Page 6 of 8 Appendix C JOD Performance Measure Form ES-C-1 VERIFICATION OF COMPLETION Job Performance Measure No.: 2008 NRC JPM E Examinee's Name: Date Performed:
Appendix C                         Job Performance Measure                   Form ES-C-1 PERFORMANCE INFORMATION AP-SW.2, step 2.a.2 RNO Performance Step: 4  IF adequate cooling can NOT be supplied to a running D/G, THEN perform the following:
a) Pull stop affected D/G.
b) Immediately depress voltage shutdown pushbutton.
Standard:                       D/G A and B voltmeters read 0volts.                       -
Recognizes no Diesel Generators are running and performs no actions.
CUE:       Acknowledge any report.
Comment:
AP-SW.2, step 2.a.3.a RNO
/, Performance Step: 5    IF no SW pumps can be operated, THEN perform the following:
a) Trip the reactor.
Standard:             Depresses Reactor Emergency Trip Pushbutton.
CUE:       Acknowledge any report.
Comment:
AP-SW.2, step 2.a.3.b RNO
/, Performance Step: 6   WHEN all E-0 Immediate Actions done, THEN trip BOTH RCPS.
Standard:             E-0Immediate Actions: (these actions performed from memory)
: 1. Verify Reactor Trip - Neutron flux lowering, at least one train of Reactor trip breakers open and MRPl indicates all rods are on the bottom.
: 2. Verifies Turbine is tripped - Turbine Stop valves are closed as indicated on EHC valve status panel. SVL Closed Green light on and SVR Closed Green light on.
: 3. Verify Both Trains of AC Emergency Busses energized to at least 420 volts: Busses 14,16,17 and 18 Volt-meters for Busses 14,16, 17 and 18 all read -480 VAC.
: 4. Check if SI is Actuated: Any SI Annunciator LIT -     -
Annunciators D-19, 21, 22 and 28 extinguished and no indications that an SI is required.
Trir, both ACPs:
: 1. A RCF H/S to Stop Red light off and Green light on.
: 2. B RCP H/S to Stop Red light off and Green light on.
(Critical steps are to trip both RCPs.)
CUE:     Acknowledge any report.
Comment:
Page 5 of 8
 
I Appendix C                        J o l ~Performance Measure         Form ES-C-1 PERFORMANCE INFORMATION AP-SW.2, step 2.a.3.c RNO 4 Performance Step: 7     Close letdown isol, AOV-427.
Standard:                       ACW-427 switch in Closed.
Red light off and Green light on.
CUE:     Acknowledge any report.
Comment:
AP-SW.2, step 2.a.3.d RNO (End Alternate Path)
Performance Step: 8     Close excess letdown, HCV-123.
Standard:               HCV-123 is at 0% demand.
CUE:     Acknowledge any report.
CUE:     No further action is required.
Comment:
Terminating Cue:           Evaluation on this JPM is complete.
STOP TIME:                                   TIME CRITICAL STOP TIME:
Page 6 of 8
 
Appendix C                       JODPerformance Measure       Form ES-C-1 VERIFICATION OF COMPLETION Job Performance Measure No.: 2008 NRC JPM E Examinees Name:
Date Performed:
Facility Evaluator:
Facility Evaluator:
Number of Attempts:
Number of Attempts:
Line 341: Line 679:
Question Documentation:
Question Documentation:
Question:
Question:
Response:
 
Result: UNSAT -- SAT Examiner's Signature: Date:
===Response===
Page 7 of 8 Appendix C Jclb Performance Measure JPM CUE SHEET Form ES-C-1 Initial Conditions: You are the (20. 0 I will be the CRS if you need one. The plant is at 100% power in a normal 50/50 electrical lineup. The running Service Water pumps have just tripped. Initiating Cue: The CRS directs you to perform AP-SW.2, LOSS OF SERVICE WATER. Page 8 of 8 Appendix C Job Performance Measure Worksheet Form ES-C-1 Facility:
Result:                     SAT              UNSAT Examiners Signature:                                 Date:
Ginna Task No.: 064-007-01  
Page 7 of 8
-01 A TasWJPM Title: Shutdown the "A" Emergency Diesel JPM No.: 2008 NRC JPM F Generator WA  
 
Appendix C                         Jclb Performance Measure               Form ES-C-1 JPM CUE SHEET Initial Conditions:   You are the (20.
I will be the CRS if you need one.
The plant is at 100% power in a normal 50/50electrical lineup.
The running Service Water pumps have just tripped.
Initiating Cue:     The CRS directs you to perform AP-SW.2, LOSS OF SERVICE WATER.
Page 8 of 8
 
Appendix C                           Job Performance Measure                 Form ES-C-1 Worksheet Facility:           Ginna                               Task No.:   064-007-01-01A TasWJPM
 
==Title:==
Shutdown the "A" Emergency Diesel JPM No.:       2008 NRC JPM F Generator WA  


==Reference:==
==Reference:==
064 A4.06    3.9 / 3.9 Examinee:                                              NRC Examiner:
Facility Evaluator:                                    Date:
Method of testina:
Simulated Performance:                                Actual Performance:    X Classroom          Simula.tor      X    Plant Applicability: RO/SRO SUBMITTED BY:                      Ted Coe                      DATE:    6/30/08 D e wloper REVIEWED BY:                      Art Vest                      DATE:    6/30/08 Training Technical Reviewer REVIEWED BY:                    Don Dettman                      DATE:    6/30/08 Operations Technical Reviewer APPROVED BY:                    John Brown                      DATE:      6/30/08 Training Management Page 1 of 13


064 A4.06 3.9 / 3.9 Examinee:
Appendix C                                   Job Performance Measure                   Form ES-C-1 Worksheet Task Standard:             The A D/G shutdown and all critical tasks evaluated as satisfactory.
NRC Examiner:
Required Materials:        None General  
Facility Evaluator:
Date: Method of testina: Simulated Performance: Actual Performance:
X Classroom Simula.tor X Plant Applicability:
RO/SRO SUBMITTED BY: Ted Coe DATE: 6/30/08 Dew loper REVIEWED BY: Art Vest DATE: 6/30/08 Training Technical Reviewer REVIEWED BY: Don Dettman DATE: 6/30/08 Operations Technical Reviewer APPROVED BY: John Brown DATE: 6/30/08 Training Management Page 1 of 13 Appendix C Job Performance Measure Worksheet Form ES-C-1 Task Standard:
Required Materials:
None The "A D/G shutdown and all critical tasks evaluated as satisfactory. General  


==References:==
==References:==
STP-0-12.1: EMEiRGENCY DIESEL GENERATOR A, Rev. 00201 Handouts:                  STP-0-12.1: EMERGENCY DIESEL GENERATOR A, Rev. 00201 Time Critical Task:        NO Validation Time:            20 minutes Alternate Path:            NO Instructor Notes:          Ensure a marked up copy of STP-0-12.1: EMERGENCY DIESEL GENERATOR A, Rev. 00201 is ready to give to the operator during the Initiating Cue.
READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
Initial Conditions:              0  You are an extra RO.
0  The plant is at 100% power with a normal electrical lineup.
0  The A EDG is running for the monthly surveillance per STP                                      12.1 through Step 6.2.42.
All readings have been taken and evaluated as satisfactory.
There is an A 0 available at the A DIG.
The Diesel has run for 65 minutes, all readings have been taken.
The A 0 has the data sheets.
Bi-Annual selected Service Water Pump starts are not required.
Initiating Cue:            The CRS has directed you to shutdown the  A DIG per STP-0-12.1 steps 6.3 through 16.3.19.
CUE: Hand the Operator a marked up copy of STP-0-12.1, EMERGENCY DIESEL GENERATOR A, Rev. 00201.
Page 2 of 13
Appendix C                            Job Performance Measure                Form ES-C-1 Worksheet SIMIULATOR SETUP For the 2008 ILT NRC Exam load I/C # 176 and Insert Manual Triggers 1 and 2 to reset DG1A ELCP Annunciator Panel, when requested in performance step 24.
or 100% power IC with normal electrical lineup (IC-19).
        "A" D/G running at between 2025 and 2050 W per STP-0-12.1, step 6.2.36 rev. 00201.
Ensure "A" SW running and "C" SW stopped.
Ensure SW selected to "A" SW Pump.
Complete and mark up STP-0-12.1 through Step 6.2.42.
Insert Manual Triggers 1 and 2 to reset DG1A ELCP Annunciator Panel, when requested in performance step 24.
IPage 3 of 13
Appendix C                        Jot) Performance Measure                    Form ES-C-1 PERFORMANCE INFORMATION START TIME:
d = CRITICAL STEP STP-0-12.1, step 6.3.1.1 Performance Step: 1    WHEN Emergency Diesel Generator A has operated between 2025 and 2050 KW for a period of greater than 60 minutes but less than cr equal to 115 minutes, THEN UNLOAD Emergency Diesel Generator A as follows:
: 1. RECORD time unloading begins.
Standard:              Records time unloading begins.
Comment:
STP-0-12.1, step 6.3.1.2
/, Performance Step: 2      IF the D/G A LOAD LIMIT on mechanical governor is NOT in the MAX FUEL. position, THEN PERFORM the following:
OTHERWISE, MARK this Step N/A
: a. ADJUST Emergency Diesel Generator A load to between 192!5 and 1950 KW using the D/G A GOVERNOR switch AND MAINTAIN Power Factor 0.9 (lag) using the D/G A AUTO VOLTAGE CONTROL RHEOSTAT as necessary.
: b. RESTORE LOAD LIMIT setting to normal (MAX FUEL).
Standard:                    0  Calls the A 0 to request if LOAD LIMIT setting is at MAX FUEL.
0  Adjusts D/G A load to between 1925 and 1950 KW using the DIG A GOVERNOR switch.
0  Maintains Power Factor 0.9 (lag) using the D/G A AUTO VOLTAGE CONTROL RHEOSTAT.
0  Calls the A 0 to restore LOAD LIMIT setting to MAX FUEL.
CUE:    When asked about Load Limit: LOAD LIMIT is NOT at Max Fuel.
When told to adjust Load Limit: LOAD LIMIT is now at Max Fuel.
Comment:
Page 4 of 13


STP-0-12.1:
Appendix C                       Joli Performance Measure                   Form ES-C-1 PERFORMANCE INFORMATION STP-O-12,,1,step 6.3.1.3 Performance Step: 3 IF the Mechanical Governor was adjusted to lock the load, THEN ADJUST Emergency Diesel Generator A load to between 2150 and 2175 KW using DIG A GOVERNOR switch AND MAlNTAlhl Power Factor at approximately 0.9 (lag) using D/G A AUTO VOLTAGE CONTROL RHEOSTAT as necessary.
EMEiRGENCY DIESEL GENERATOR A, Rev. 00201 Handouts:
OTHERWISE, MARK this Step N/A.
STP-0-12.1:
Standard:                 0   Adjusts D/G A load to between 2150 and 2175 Kw using D/G A GOVERNOR switch.
EMERGENCY DIESEL GENERATOR A, Rev. 00201 Time Critical Task: NO Validation Time: 20 minutes Alternate Path:
Maintains Power Factor at approximately 0.9 (lag) using D/G A AUTO VOLTAGE CONTROL RHEOSTAT.
NO Instructor Notes: Ensure a marked up copy of STP-0-12.1:
Comment:
EMERGENCY DIESEL GENERATOR A, Rev. 00201 is ready to give to the operator during the Initiating Cue. READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
STP-O-12,1, step 6.3.1.4
Initial Conditions:
/, Performance step: 4  UNLOAD IEmergency Diesel Generator A; to 400 KW by intermittently turning DIG A GOVERNOR switch in the lower direction, AND MAINTAIN Power Factor at approximately 0.9 (lag) using D/G A AUTO VOLTAGE CONTROL RHEOSTAT as necessary Standard:                 0   Does not violate the D/G A unloading rate of approximately 500 Kw every 30 seconds.
0 0 0 You are an extra RO. The plant is at 100% power with a normal electrical lineup. The "A" EDG is running for the monthly surveillance per STP 12.1 through Step 6.2.42. All readings have been taken and evaluated as satisfactory.
Unloads D/G A, to 400 KW by intermittently turning DIG A GCVERNOR switch in the lower direction.
There is an A0 available at the A DIG. The Diesel has run for 65 minutes, all readings have been taken. The A0 has the data sheets. Bi-Annual selected Service Water Pump starts are not required.
Initiating Cue: The CRS has directed you to shutdown the "A DIG per STP-0-12.1 steps 6.3 through 16.3.19. CUE: Hand the Operator a marked up copy of STP-0-12.1, EMERGENCY DIESEL GENERATOR A, Rev. 00201. Page 2 of 13 Appendix C Job Performance Measure Worksheet Form ES-C SI MI ULATO R SETUP For the 2008 ILT NRC Exam load I/C # 176 and Insert Manual Triggers 1 and 2 to reset DG1A ELCP Annunciator Panel, when requested in performance step 24. or 100% power IC with normal electrical lineup (IC-1 9). "A" D/G running at between 2025 and 2050 W per STP-0-12.1 , step 6.2.36 rev.
00201. Ensure "A" SW running and "C" SW stopped. Ensure SW selected to "A" SW Pump. Complete and mark up STP-0-12.1 through Step 6.2.42. Insert Manual Triggers 1 and 2 to reset DG1A ELCP Annunciator Panel, when requested in performance step
: 24. IPage 3 of 13 Jot) Performance Measure Form ES-C-1 Appendix C PERFORMANCE INFORMATION START TIME: d = CRITICAL STEP STP-0-12.1, step 6.3.1.1 WHEN Emergency Diesel Generator A has operated between 2025 and 2050 KW for a period of greater than 60 minutes but less than cr equal to 115 minutes, THEN UNLOAD Emergency Diesel Generator A as follows:
: 1. RECORD time unloading begins. Performance Step: 1 Standard:
Records time unloading begins. Comment: STP-0-12.1, step 6.3.1.2 IF the D/G A LOAD LIMIT on mechanical governor is NOT in the MAX FUEL. position, THEN PERFORM the following:
OTHERWISE, MARK this Step N/A ,/ Performance Step: 2 a. ADJUST Emergency Diesel Generator A load to between 192!5 and 1950 KW using the D/G A GOVERNOR switch AND MAINTAIN Power Factor 0.9 (lag) using the D/G A AUTO VOLTAGE CONTROL RHEOSTAT as necessary.
: b. RESTORE LOAD LIMIT setting to normal (MAX FUEL). Standard:
0 Calls the A0 to request if LOAD LIMIT setting is at MAX FUEL. 0 Adjusts D/G A load to between 1925 and 1950 KW using the DIG A GOVERNOR switch. 0 Maintains Power Factor 0.9 (lag) using the D/G A AUTO VOLTAGE CONTROL RHEOSTAT.
0 Calls the A0 to restore LOAD LIMIT setting to MAX FUEL. CUE: When asked about Load Limit: LOAD LIMIT is NOT at Max Fuel. When told to adjust Load Limit:
LOAD LIMIT is now at Max Fuel.
Comment: Page 4 of 13 Appendix C Joli Performance Measure Form ES-C-1 PERFORMANCE INFORMATION STP-O-12,,1, step 6.3.1.3 IF the Mechanical Governor was adjusted to lock the load, THEN ADJUST Emergency Diesel Generator A load to between 2150 and 2175 KW using DIG A GOVERNOR switch AND MAlNTAlhl Power Factor at approximately 0.9 (lag) using D/G A AUTO VOLTAGE CONTROL RHEOSTAT as necessary.
OTHERWISE, MARK this Step N/A. Performance Step: 3 Standard:
0 Adjusts D/G A load to between 2150 and 2175 Kw using D/G A GOVERNOR switch. Maintains Power Factor at approximately 0.9 (lag) using D/G A AUTO VOLTAGE CONTROL RHEOSTAT.
Comment: STP-O-12,1, step 6.3.1.4 UNLOAD IEmergency Diesel Generator A; to 400 KW by intermittently turning DIG A GOVERNOR switch in the lower direction, AND MAINTAIN Power Factor at approximately 0.9 (lag) using D/G A AUTO VOLTAGE CONTROL RHEOSTAT as necessary  
,/ Performance step: 4 Standard:
0 Does not violate the D/G A unloading rate of approximately 500 Kw every 30 seconds. Unloads D/G A, to 400 KW by intermittently turning DIG A GCVERNOR switch in the lower direction.
Maintains Power Factor at approximately 0.9 (lag) using D/G A AUTO VOLTAGE CONTROL RHEOSTAT.
Maintains Power Factor at approximately 0.9 (lag) using D/G A AUTO VOLTAGE CONTROL RHEOSTAT.
Comment: STP-0-12.1 , step 6.3.2 IF Bi-Annual selected Service Water Pump starts are required, THEN PEFIFORM Attachment 13, Bi-Annual Service Water Pump Starts.
Comment:
OTHERWISE, MARK this Step AND Attachment 13 N/A. Performance Step: 5 Standard:
STP-0-12.1 ,step 6.3.2 Performance Step: 5  IF Bi-Annual selected Service Water Pump starts are required, THEN PEFIFORM Attachment 13, Bi-Annual Service Water Pump Starts. OTHERWISE, MARK this Step AND Attachment 13 N/A.
Comment: Determine:;
Standard:           Determine:; from Initiating Cue, not required, marks step N/A.
from Initiating Cue, not required, marks step N/A. Page 5 of 13 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION STP-O-12,,1, step 6.3.3 WHEN Emergency Diesel Generator A load has been reduced to 400 KW, THEN TRIP one Emergency Diesel Generator A supply breaker. 4 Performance Step:
Comment:
6 Standard:
Page 5 of 13
0 WHEN D/G A is at -400 KW, TRIPS one DIG A supply breaker for Bus 14 or Bus 18. 0 Green light on, red light off. 0 If Cliesel Generator Trips on Reverse Power due to operator error, the step will be evaluated as Unsat.
 
Comment: STP-0-12.1, step 6.3.4 WHEN Errlergency Diesel Generator A load has been reduced to approximately 200 Kw AND Power Factor is 0.9 (lag), THEN TRIP the remaining closed Emergency Diesel Generator A supply breaker. 4 Performance step: 7 Standard:
Appendix C                     Job Performance Measure                     Form ES-C-1 PERFORMANCE INFORMATION STP-O-12,,1,step 6.3.3 4  Performance Step: 6  WHEN Emergency Diesel Generator A load has been reduced to 400 KW, THEN TRIP one Emergency Diesel Generator A supply breaker.
0 WHEN D/G A load is at -200 KW and Power Factor is 0.9 (lag), TRIPS the remaining closed D/G A supply breaker for Bus 14 or Bus 18. 0 Green light on, red light off. 0 If Diesel Generator Trips on Reverse Power due to operator error, the step will be evaluated as Unsat.
Standard:               0   WHEN D/G A is at -400 KW, TRIPS one DIG A supply breaker for Bus 14 or Bus 18.
Comment: STP-0-12.1, step 6.3.5 RECORD lime breaker was opened. Performance Step:
0   Green light on, red light off.
8 Standard: Records tirne breaker was opened. Comment: Page 6 of 13 Appendix C Job Performance Measure Form ES-C-1 PERFCIRMANCE INFORMATION Performance Step: 9 Standard:
0   If Cliesel Generator Trips on Reverse Power due to operator error, the step will be evaluated as Unsat.
Comment: 4 Performance Step: IO Standard:
Comment:
Comment: 4 Performance Step: 11 Standard:
STP-0-12.1, step 6.3.4 4  Performance step: 7  WHEN Errlergency Diesel Generator A load has been reduced to approximately 200 Kw AND Power Factor is 0.9 (lag), THEN TRIP the remaining closed Emergency Diesel Generator A supply breaker.
Comment: Performance Step: 12 Standard:
Standard:               0 WHEN D/G A load is at -200 KW and Power Factor is 0.9 (lag), TRIPS the remaining closed D/G A supply breaker for Bus 14 or Bus 18.
Comment: STP-O-12:1, step 6.3.6 IF Attachmlent 13, Bi-Annual Service Water Pump Starts, was performed, THEN ENSURE Service Water Pumps AND Selector Switches are aligned to the desired configuration.
0 Green light on, red light off.
OTHERWI!SE, MARK this Step N/A. Determines from Initiating Cue, not required, marks step N/A. STP-0-12.1, step 6.3.7 PLACE D/G A UNIT/PARALLEL OPERATION SELECTOR switch to UNIT position.
0   If Diesel Generator Trips on Reverse Power due to operator error, the step will be evaluated as Unsat.
D/G A UNlT/PARALLEL OPERATION SELECTOR switch in UNIT positiion.
Comment:
STP-0-12.1, Step 6.3.8 PLACE D/G A SYNCHROSCOPE switch in the BUS 14 or BUS 18 position.
STP-0-12.1, step 6.3.5 Performance Step: 8 RECORD lime breaker was opened.
D/G A SYNCHROSCOPE switch in the BUS 14 or BUS 18 posit ion. STP-0-12.1, step 6.3.9 IF Emergeiicy Diesel Generator A frequency is high, THEN OPERATE D/G A GOVERNOR switch to return to a setting of between 60 and 60.1 Hertz (revolving slowly in the clockwise direction)
Standard:           Records tirne breaker was opened.
AND TRANSFER frequency setting data to Attachment 3, As Found/As Left Voltage and Frequency.
Comment:
OTHERWISE, MARK this Step N/A. Determines frequency is satisfactory, marks step N/A. Page 7 of 13
Page 6 of 13
- Appendix C ~ ~~ ~~ ~~ Jot) PerformanceMeaGre Form ES-C-1 PERFORMANCE INFORMATION 4 Performance Step: 13 Standard:
 
Comment: Performance Step:
Appendix C                       Job Performance Measure                   Form ES-C-1 PERFCIRMANCE INFORMATION STP-O-12:1, step 6.3.6 Performance Step: 9 IF Attachmlent 13, Bi-Annual Service Water Pump Starts, was performed, THEN ENSURE Service Water Pumps AND Selector Switches are aligned to the desired configuration.
14 Standard:
OTHERWI!SE, MARK this Step N/A.
STP-0-12.1, step 6.3.10 PLACE D/G A SYNCHROSCOPE switch to the OFF position.
Standard:           Determines from Initiating Cue, not required, marks step N/A.
D/G A SYNCHROSCOPE switch in off. STP-0-12.1, step 6.3.1 1 MEASURE! the Emergency Diesel Generator A speed using a photo-tachometer, AND RECORD speed data on Attachment 3, As Found/& Left Voltage and Frequency.
Comment:
0 0 Directs the A0 to measure the D/G A speed using a Photo-tachometer.
STP-0-12.1, step 6.3.7 4  Performance Step: OI PLACE D/G A UNIT/PARALLEL OPERATION SELECTOR switch to UNIT position.
Records the speed data on Attachment
Standard:            D/G A UNlT/PARALLEL OPERATION SELECTOR switch in UNIT positiion.
: 3. CUE: Comment: A D/G speed is 900 rpm. STP-0-12.1, step 6.3.1 2 establish Emergency Diesel Generator A output voltage between 480 and 490 Volts (adjust as close to 480 volts as possible)
Comment:
AND RECORD voltage data on Attachment 3, As FoundAs Left Voltage and Frequency.
STP-0-12.1, Step 6.3.8 4  Performance Step: 11  PLACE D/G A SYNCHROSCOPE switch in the BUS 14 or BUS 18 position.
Performance Step: 15 ADJUST CVG A AUTO VOLTAGE CONTROL RHEOSTAT to Standard:
Standard:            D/G A SYNCHROSCOPE switch in the BUS 14 or BUS 18 position.
Comment: D/Ci A output voltage between 480 and 490 Volts. Records voltage data on Attachment
Comment:
: 3. STP-0-12.1, step 6.3.13 RHEOSTAT position on Attachment 14, Auto Voltage Control Rheostat After Start - As Left, by sketching in the dial setting. Performance Step: 16 RECORD the as left D/G A AUTO VOLTAGE CONTROL Standard:
STP-0-12.1, step 6.3.9 Performance Step: 12  IF Emergeiicy Diesel Generator A frequency is high, THEN OPERATE D/G A GOVERNOR switch to return to a setting of between 60 and 60.1 Hertz (revolving slowly in the clockwise direction) AND TRANSFER frequency setting data to Attachment 3, As Found/As Left Voltage and Frequency.
Sketching in the dial setting on Attachment 14.
OTHERWISE, MARK this Step N/A.
Comment: Page 8 of 13 Appendix C Jot) Performance Measure Form ES-C-1 PERFORMANCE INFORMATION 4 Performance Step: 17 Standard:
Standard:            Determines frequency is satisfactory, marks step N/A.
Comment: ,/ Performance Step: 18 Standard:
Comment:
STP-0-12.1, step 6.3.1 4 TURN the D/G A CONTROL switch to the STOP position.
Page 7 of 13
D/G A CONTROL switch to STOP then spring returns to mid position (red flagged). STP-0-12.1, step 6.3.1 5 PUSH ANI)
 
HOLD the D/G A VOLTAGE SHUTDOWN button (Black button) for a few seconds immediately after stopping Emergency Diesel Generator A. Pushes and holds the DIG A VOLTAGE SHUTDOWN button for a few seconds immediately after stopping D/G A. CUE: Comment: If requested, report as the AO, "A' D/G has stopped. STP-0-12.1, step 6.3.1 6 WHEN the Emergency Diesel Generator A has stopped rolling, THEN PUSH the following buttons: ,/ Performance Step:
-                                         ~  ~~                   ~~     ~~
1 g D/GA RESET 0 D/G A FIELD RESET Standard:
Appendix C                        Jot) PerformanceMeaGre                       Form ES-C-1 PERFORMANCE INFORMATION STP-0-12.1, step 6.3.10 4  Performance Step: 13    PLACE D/G A SYNCHROSCOPE switch to the OFF position.
DIG A RESET button depressed.
Standard:              D/G A SYNCHROSCOPE switch in off.
CUE: Comment: DIG A FIELD RESET button depressed.
Comment:
If requested, report as the AO, "A" DIG has stopped. Page 9 of 13 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION STP-0-12.1 , step 6.3.1 7 WHEN the Emergency Diesel Generator A is reset, THEN VERIFY the following indicating lamps are illuminated (MCB Rear): Performance Step: 20 0 0 AlFi START SOLENOID VALVE 1 POWER AVAILABLE AlFi START SOLENOID VALVE 2 POWER AVAILABLE START RELAY 1 POWER AVAILABLE START RELAY 2 POWER AVAILABLE Standard: Verifies the following indicating lamps are illuminated:
STP-0-12.1, step 6.3.1 1 Performance Step: 14    MEASURE! the Emergency Diesel Generator A speed using a photo-tachometer, AND RECORD speed data on Attachment 3, As Found/& Left Voltage and Frequency.
0 0 0 AlFt START SOLENOID VALVE 1 POWER AVAILABLE AlFl START SOLENOID VALVE 2 POWER AVAILABLE START RELAY 1 POWER AVAILABLE START RELAY 2 POWER AVAILABLE Comment: STP-0-12.1 , step 6.3.1 8 DECLARE, Emergency Diesel Generator A unavailable.
Standard:                  0   Directs the A 0 to measure the D/G A speed using a Photo-tachometer.
Performance Step: 21 Standard:
Records the speed data on Attachment 3.
CUE: Acknowledge report. Comment: Informs the CRS/HCO A D/G is unavailable.
CUE:     A D/G speed is 900 rpm.
STP-0-12.1 , step 6.3.1 9.1 VERIFY DI'G A CONTROL switch reset alarm operability as follows: 1. VERIFY no other alarm condition exists on the Emergency Performance Step: 22 Diesel Generator A alarm panel. Standard:
Comment:
No alarms. CUE: Comment: If requested, report as the AO, no other alarm condition exists on the Emergency Diesel Generator A alarm panel. Page 10 of 13 Appendix C Jot) Performance Measure Form ES-C-1 PERFORMANCE INFORMATION STP-0-12.1, step 6.3.1 9.2 PLACE DPS A CONTROL switch in the PULL STOP position AND VERIFY the following:  
STP-0-12.1, step 6.3.1 2 Performance Step: 15    ADJUST CVG A AUTO VOLTAGE CONTROL RHEOSTAT to establish Emergency Diesel Generator A output voltage between 480 and 490 Volts (adjust as close to 480 volts as possible) AND RECORD voltage data on Attachment 3, As FoundAs Left Voltage and Frequency.
,/ Performance Step: 23 MCB Alarm J-24, EMERGENCY DIESEL GEN 1A PANEL, is illuminated.
Standard:                       D/Ci A output voltage between 480 and 490 Volts.
0 Emergency Diesel Generator A START RELAY 1 POWER AVAILABLE AND START RELAY 2 POWER AVAILABLE lights are extinguished (MCB). Standard: D/G A CONTROL switch in PULL STOP. MCB Alarm J-24, EMERGENCY DIESEL GEN 1A PANEL, is illuminated.
Records voltage data on Attachment 3.
0 Emergency Diesel Generator A START RELAY 1 POWER AVAILABLE AND START RELAY 2 POWER AVAILABLE lights are extinguished (MCB). Comment: STP-0-12.1, step 6.3.1 9.3 VERIFY Ernergency Diesel Generator A shutdown reset annunciator (R3) is illuminated.
Comment:
Performance Step: 24 DEPRESS ACK button at DGlA ELCP Annunciator Panel AND Standard:
STP-0-12.1, step 6.3.13 Performance Step: 16    RECORD the as left D/G A AUTO VOLTAGE CONTROL RHEOSTAT position on Attachment 14, Auto Voltage Control Rheostat After Start - As Left, by sketching in the dial setting.
Contacts A0 to perform step 6.3.1 9.3. CUE: Acknowledge request. Simulator Operator: Insert Manual Triggers 1 and 2 to reset DGlA ELCP Annunciator CUE: Comment: Panel. ACK button at DGlA ELCP Annunciator Panel has been depressed and (R3) is illuminated.
Standard:               Sketching in the dial setting on Attachment 14.
Terminating Cue: Evaluationi on this JPM is complete.
Comment:
STOP TIME: TIME CRITICAL STOP TIME: Page 11 of 13 Appendix C Job Performance Measure Form ES-C-1 VERIFICATION OF COMPLETION - Job Performance Measure No.: 2008 FJRC JPM F Examinee's Name: Date Performed:
Page 8 of 13
 
Appendix C                           Jot) Performance Measure                   Form ES-C-1 PERFORMANCE INFORMATION STP-0-12.1, step 6.3.14 4 Performance Step: 17    TURN the D/G A CONTROL switch to the STOP position.
Standard:                D/G A CONTROL switch to STOP then spring returns to mid position (red flagged).
Comment:
STP-0-12.1, step 6.3.15
,/ Performance Step: 18    PUSH ANI) HOLD the D/G A VOLTAGE SHUTDOWN button (Black button) for a few seconds immediately after stopping Emergency Diesel Generator A.
Standard:                Pushes and holds the DIG A VOLTAGE SHUTDOWN button for a few seconds immediately after stopping D/G A.
CUE:   If requested, report as the AO, AD/G has stopped.
Comment:
STP-0-12.1, step 6.3.1 6
/,  Performance Step: 1g    WHEN the Emergency Diesel Generator A has stopped rolling, THEN PUSH the following buttons:
D/GA RESET 0   D/G A FIELD RESET Standard:                       DIG A RESET button depressed.
DIG A FIELD RESET button depressed.
CUE:    If requested, report as the AO, A DIG has stopped.
Comment:
Page 9 of 13
 
Appendix C                         Job Performance Measure                     Form ES-C-1 PERFORMANCE INFORMATION STP-0-12.1 , step 6.3.17 Performance Step: 20    WHEN the Emergency Diesel Generator A is reset, THEN VERIFY the following indicating lamps are illuminated (MCB Rear):
0 AlFi START SOLENOID VALVE 1 POWER AVAILABLE AlFi START SOLENOID VALVE 2 POWER AVAILABLE START RELAY 1 POWER AVAILABLE START RELAY 2 POWER AVAILABLE Standard:               Verifies the following indicating lamps are illuminated:
0 AlFt START SOLENOID VALVE 1 POWER AVAILABLE AlFl START SOLENOID VALVE 2 POWER AVAILABLE START RELAY 1 POWER AVAILABLE START RELAY 2 POWER AVAILABLE Comment:
STP-0-12.1,step 6.3.18 Performance Step: 21    DECLARE, Emergency Diesel Generator A unavailable.
Standard:                 Informs the CRS/HCO A D/G is unavailable.
CUE:      Acknowledge report.
Comment:
STP-0-12.1 ,step 6.3.19.1 Performance Step: 22    VERIFY DIG A CONTROL switch reset alarm operability as follows:
: 1. VERIFY no other alarm condition exists on the Emergency Diesel Generator A alarm panel.
Standard:                 No alarms.
CUE:     If requested, report as the AO, no other alarm condition exists on the Emergency Diesel Generator A alarm panel.
Comment:
Page 10 of 13
 
Appendix C                         Jot) Performance Measure                 Form ES-C-1 PERFORMANCE INFORMATION STP-0-12.1, step 6.3.1 9.2
,/ Performance Step: 23    PLACE DPS A CONTROL switch in the PULL STOP position AND VERIFY the following:
MCB Alarm J-24, EMERGENCY DIESEL GEN 1A PANEL, is illuminated.
0 Emergency Diesel Generator A START RELAY 1 POWER AVAILABLE AND START RELAY 2 POWER AVAILABLE lights are extinguished (MCB).
Standard:                       D/G A CONTROL switch in PULL STOP.
MCB Alarm J-24, EMERGENCY DIESEL GEN 1A PANEL, is illuminated.
0 Emergency Diesel Generator A START RELAY 1 POWER AVAILABLE AND START RELAY 2 POWER AVAILABLE lights are extinguished (MCB).
Comment:
STP-0-12.1, step 6.3.1 9.3 Performance Step: 24      DEPRESS ACK button at DGlA ELCP Annunciator Panel AND VERIFY Ernergency Diesel Generator A shutdown reset annunciator (R3) is illuminated.
Standard:                 Contacts A 0 to perform step 6.3.1 9.3.
CUE:     Acknowledge request.
Simulator Operator: Insert Manual Triggers 1 and 2 to reset DGlA ELCP Annunciator Panel.
CUE:     ACK button at DGlA ELCP Annunciator Panel has been depressed and (R3) is illuminated.
Comment:
Terminating Cue:             Evaluationi on this JPM is complete.
STOP TIME:                                   TIME CRITICAL STOP TIME:
Page 11 of 13
 
Appendix C                       Job Performance Measure       Form ES-C-1 VERIFICATION OF COMPLETION                   -
Job Performance Measure No.: 2008 FJRC JPM F Examinees Name:
Date Performed:
Facility Evaluator:
Facility Evaluator:
Number of Attempts:
Number of Attempts:
Time to Complete: Question Documentation:
Time to Complete:
Question Documentation:
Question:
Question:
Response:
 
Result: UNSAT -- SAT Examiner's Signature:
===Response===
Date: Page 12 of 13 Appendix C Job Performance Measure JPM CUE SHEET Form ES-C-1 Initial Conditions:
Result:                     SAT              UNSAT Examiners Signature:                                   Date:
0 0 e You are an extra RO. The plant is at 100% power with a normal electrical lineup. The "A" EIIG is running for the monthly surveillance per STP 12.1 through Step 6.2.42. All readings have been taken and evaluated as satisfactory.
Page 12 of 13
There is ai A0 available at the A D/G. The Diesel has run for 65 minutes, all readings have been taken. The A0 has the data sheets. Bi-Annual selected Service Water Pump starts are not required.
 
Initiating Cue: The CRS has directed you to shutdown the "A D/G per STP-0-12.1 steps 6.3 through 6.3.1 9. Page 13 of 13 Appendix C Jot) Performance Measure Worksheet Form ES-C ~ Facility: Ginna Task No.: 015-007-01-01A TasWJPM Title: Remove a Power Range Channel JPM No.: 2008 NRC JPM G from Service.
Appendix C                         Job Performance Measure                   Form ES-C-1 JPM CUE SHEET Initial Conditions:   0   You are an extra RO.
The plant is at 100% power with a normal electrical lineup.
The A EIIG is running for the monthly surveillance per STP                           12.1 through Step 6.2.42.
All readings have been taken and evaluated as satisfactory.
There is a i A 0 available at the A D/G.
The Diesel has run for 65 minutes, all readings have been taken.
The A 0 has the data sheets.
Bi-Annual selected Service Water Pump starts are not required.
Initiating Cue:     The CRS has directed you to shutdown the A D/G per STP-0-12.1 steps 6.3 through 6.3.1 9.
Page 13 of 13
 
Appendix C                           Jot) Performance Measure                 Form ES-C-1
-                  ~
Worksheet Facility:           Ginna                                 Task No.:   015-007-01-01A TasWJPM
 
==Title:==
Remove a Power Range Channel         JPM No.:   2008 NRC JPM G from Service.
WA  
WA  


==Reference:==
==Reference:==
015 A2.02    3.1 / 3.5*
Examinee:                                              NRC Examiner:
Facility Evaluator:                                    Date:
Method of testina:
Simulated Performance:                                Actual Performance:    X Classroom            Simulator      X    Plant Applicability: RO/SRO SUBMITTED BY:                      Ted Coe                        DATE:    6/30/08 Developer REVIEWED BY:                      Art Vest                      DATE:    6/30/08 Training Technical Reviewer REVIEWED BY:                    Don Dettman                      DATE:    6/30/08 Operations Technical Reviewer APPROVED BY:                    John Blrown                      DATE:    6/30/08 Training Management Page 1 of 13


015 A2.02 3.1
Appendix C                                 Job Performance Measure                   Form ES-C-1 Worksheet Task Standard:             Remove N-41 from service and all critical tasks evaluated as satisfactory.
/ 3.5* Examinee:
Required Materials:         None General  
NRC Examiner:
Facility Evaluator: Date:
Method of testina: Simulated Performance: Actual Performance:
X Classroom Simulator X Plant Applicability:
RO/SRO SUBMITTED BY: Ted Coe DATE: 6/30/08 Developer 6/30/08 REVIEWED BY: Art Vest DATE: Training Technical Reviewer REVIEWED BY: Don Dettman DATE: 6/30/08 Operations Technical Reviewer APPROVED BY: John Blrown DATE: 6/30/08 Training Management Page 1 of 13 Appendix C Job Performance Measure Worksheet Form ES-C-1 Task Standard:
Remove N-41 from service and all critical tasks evaluated as satisfactory.
Required Materials: None General  


==References:==
==References:==
ER-NIS.3, PR Malfunction, Rev. 26 Handouts:                  ER-NIS.3, PR Malfunction, Rev. 26 Time Critical Task:        NO Validation Time:            19 minutes Alternate Path:            NO Instructor Notes:          Ensure a marked up copy of ER-NIS.3, PR Malfunction, Rev. 26 is ready to give to the operator during the Initiating Cue.
READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues.
When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
Initial Conditions:                  You are an extra RO.
Power Range channel N-41 drifted low over a period of several minutes and has been declared inoperable.
No plant transient has occurred.
Procedure ER-NIS.3 is being implemented.
Reactor power is 100%.
No other channels have been defeated.
Initiating Cue:            The CRS has directed you to remove PR N-41 from service per ER-NIS.3.
Step 4.4 Attachmtant N-41 Defeat.
All notifications ha.ve been made and approvals received.
CUE: Hand the Operator a marked up copy of ER-NIS.3, PR Malfunction, Rev. 26.
Page 2 of 13


ER-NIS.3, PR Malfunction, Rev. 26 Handouts:
Appendix C                              Job Performance Measure Form ES-C-1 Worksheet SlhAULATOR SETUP For the 2008 ILT NRC Exam load I/C # 177 or Select IC 19 (or any full power IC).
ER-NIS.3, PR Malfunction, Rev.
Place Rods in manual.
26 Time Critical Task: NO Validation Time: 19 minutes Alternate Path: NO Instructor Notes: Ensure a marked up copy of ER-NIS.3, PR Malfunction, Rev. 26 is ready to give to the operator during the Initiating Cue. READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
Place N-41 to Rod Drop Bypass, reduce gain to 0.
Initial Conditions:
Return Rod Drop Bypass to Norrrial.
You are an extra RO. Power Range channel N-41 drifted low over a period of several minutes and has been declared inoperable.
Adjust Tave = Tref.
No plant transient has occurred. Procedure ER-NIS.3 is being implemented. Reactor power is 100%. No other channels have been defeated.
Page 3 of 13
Initiating Cue: The CRS has directed you to remove PR N-41 from service per ER-NIS.3.
 
Step 4.4 Attachmtant N-41 Defeat. All notifications ha.ve been made and approvals received.
Appendix C                        Jab Performance Measure                    Form ES-C-1 PERFORMANCE INFORMATION START TIME:
CUE: Hand the Operator a marked up copy of ER-NIS.3, PR Malfunction, Rev. 26. Page 2 of 13 Appendix C Job Performance Measure Form ES-C-1 Worksheet SlhAULATOR SETUP For the 2008 ILT NRC Exam load I/C # 177 or Select IC 19 (or any full power IC). Place Rods in manual. Place N-41 to Rod Drop Bypass, reduce gain to 0. Return Rod Drop Bypass to Norrrial. Adjust Tave
.\I = CRITICAL STEP ER-NIS.3, Att. N-41 Defeat, step 1 4   Performance step: 1 IF the PPCS is operational, THEN delete NIS Channel 41 from processing by performing the following:
= Tref. Page 3 of 13 Appendix C Jab Performance Measure Form ES-C-1 PERFORMANCE INFORMATION START TIME: .\I = CRITICAL STEP ER-NIS.3, Att. N-41 Defeat, step 1 IF the PPCS is operational, THEN delete NIS Channel 41 from processing by performing the following:
: a. Sekct Group Update display.
: a. Sekct "Group Update" display. b. Select "List Server Groups".
: b. Select List Server Groups.
: c. Select NIS1 from the pick list. d. Turn "OFF scan processing, then click the "Set Scan e. Answer prompts. 4 Performance step: 1 Processing" button.
: c. Select NIS1 from the pick list.
Standard:
: d. Turn OFF scan processing, then click the Set Scan Processing button.
Deletes NIS Channel 41 from processing by performing the following:
: e. Answer prompts.
0 Selects "Group Update" display.
Standard:          Deletes NIS Channel 41 from processing by performing the following:
0 Selects "List Server Groups".
0   Selects Group Update display.
0 Selects NIS1 from the pick list. 0 Turns "OFF' scan processing, then clicks the "Set Scan Processing" button. 0 Answers prompts. Comment: ER-NIS.3, Att. N-41 Defeat, step 2 the M (MAiNUAL) position. Performance Step:
0  Selects List Server Groups.
2 Verify the ROD CONTROL BANK SELECTOR switch (MCB) is in Standard:
0  Selects NIS1 from the pick list.
ROD CONTROL BANK SELECTOR switch is selected to MANUAL. Comment: Page 4 of 13 Appendix C Jclb Performance Measure Form ES-C-1 PERFORMANCE INFORMATION ER-NIS.3, Att. N-41 Defeat, step 3 drawer) to BYPASS AND verify the following:
0  Turns OFF scan processing, then clicks the Set Scan Processing button.
Performance Step: 3 Place the DROPPED ROD MODE switch (Power Range N41A DFlOPPED ROD BYPASS (local light) is lit. 0 POWER RANGE-1 ROD DROP BYPASS (MCB bypass stalus light) is lit.
0  Answers prompts.
0 Annunciator (MCB) E-7, NIS TRIP BYPASS, is lit. Standard:
Comment:
Places the DROPPED ROD MODE to BYPASS AND verifies:
ER-NIS.3, Att. N-41 Defeat, step 2 Performance Step: 2 Verify the ROD CONTROL BANK SELECTOR switch (MCB) is in the M (MAiNUAL) position.
0 DFlOPPED ROD BYPASS (local light) is lit. 0 PCIWER RANGE-1 ROD DROP BYPASS (MCB bypass status light) is lit.
Standard:           ROD CONTROL BANK SELECTOR switch is selected to MANUAL.
0 Annunciator (MCB) E-7, NIS TRIP BYPASS, is lit. Comment: ER-NIS.3, Att. N-41 Defeat, step 4 Place T/405E DELTA T DEFEAT switch (RIL Insertion Limit Rack) to LOOP A UNIT 1 (Defeats the delta T Runback and Rodstop for the failed channel AND removes the associated delta-T input from the RIL computer-Annunciators F-30 AND F- 31 will clear if lit). 4 Pertormance Step: 4 Standard:
Comment:
Comment: Places T/405E DELTA T DEFEAT switch (RIL Insertion Limit Rack) to LOOP A UNIT 1 - Annunciators F-30 AND F-31 will clear if lit. Page 5 of 13 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION ER-NIS.3, Att. N-41 Defeat, step 5 Place the OVERTEMP TRIP bistable (Red R-1 Protection Channel 1 rack) proving switch to DEFEAT (UP) AND verify the following:
Page 4 of 13
0 Annunciator F-23, RCS 0T)T CHANNEL ALERT, is lit 0 Proving light OFF if TI-4058 > or = TI-405A IF any proving light status is NOT correct, THEN submit an ACTION Fleport on the discrepancy and continue with the channel defeat steps.
 
4 Performance Step:
Appendix C                      Jclb Performance Measure                  Form ES-C-1 PERFORMANCE INFORMATION ER-NIS.3, Att. N-41 Defeat, step 3 Performance Step: 3 Place the DROPPED ROD MODE switch (Power Range N41A drawer) to BYPASS AND verify the following:
5 Standard:
DFlOPPED ROD BYPASS (local light) is lit.
Places the OVERTEMP TRIP bistable proving switch to DEFEAT (UP)
0   POWER RANGE-1 ROD DROP BYPASS (MCB bypass stalus light) is lit.
AND verifies the following:
0   Annunciator (MCB) E-7, NIS TRIP BYPASS, is lit.
0 0 Annunciator F-23, RCS OT delta-T CHANNEL ALERT, is lit Proving light OFF if TI-4058 > or = Ti-405A Comment: ER-NIS.3, Att. N-41 Defeat, step 6 Channel 1 rack) proving switch to DEFEAT (UP) AND verify the following:
Standard:          Places the DROPPED ROD MODE to BYPASS AND verifies:
Annunciator F-32, RCS OP delta-T CHANNEL ALERT, is lit 0 Proving light OFF if TI-405B > or = TI-405C IF any proving light status is NOT correct, THEN submit an ACTION Report on the discrepancy and continue with the channel defeat steps. ,/ Performance Step: 6 Place the OVERPOWER TRIP bistable (Red R-1 Protection 4 Standard: Places the OVERPOWER TRIP bistable proving switch to DEFEAT (IJP) AND verifies the following:
0    DFlOPPED ROD BYPASS (local light) is lit.
0 0 Anriunciator F-32, RCS OP delta-T CHANNEL ALERT, is lit Proving light OFF if TI-4058 > or = TI-405C Comment: Page 6 of 13 Appendix C Jot) Performance Measure Form ES-C-1 PER FORM ANCE I N FO RMATION ER-NIS.3, Att. N-41 Defeat, step 7 Performance Step:
0    PCIWER RANGE-1 ROD DROP BYPASS (MCB bypass status light) is lit.
7 Verify the following bistables are lit: a. TC405A OP Delta T LOOD A b. TC405C OT Delta T Loop A Standard: Verifies bistables are lit:
0    Annunciator (MCB) E-7, NIS TRIP BYPASS, is lit.
: a. TC405A OP Delta T Loop A b. TC405C OT Delta T Loop A Comment: ER-NIS.3, Att. N-41 Defeat, step 8 Place the lJPPER SECTION DEFEAT switch (Detector Current Comparator- Miscellaneous Control
Comment:
& Indications drawer) to the PRN41 position AND verify the following:
ER-NIS.3, Att. N-41 Defeat, step 4 4  Pertormance Step: 4 Place T/405E DELTA T DEFEAT switch (RIL Insertion Limit Rack) to LOOP A UNIT 1 (Defeats the delta T Runback and Rodstop for the failed channel AND removes the associated delta-T input from the RIL computer-Annunciators F-30 AND F-31 will clear if lit).
4 Performance Step: 8 Local light for CHANNEL DEFEAT upper section is lit. Standard:
Standard:          Places T/405E DELTA T DEFEAT switch (RIL Insertion Limit Rack) to LOOP A UNIT 1 Annunciators F-30 AND F-31 will clear if lit.
Places the UPPER SECTION DEFEAT switch to the PRN41 position AND verifies:
Comment:
Local light for CHANNEL DEFEAT upper section is lit. Comment: ER-NIS.3, Att. N-41 Defeat, step 9 Place the LOWER SECTION DEFEAT switch (Detector Current Comparator-Miscellaneous Controls & Indications drawer) to the PRN41 position AND verify the following:
Page 5 of 13
4 Performance Step: g Local light for CHANNEL DEFEAT lower section is lit. Standard:
 
Places the LOWER SECTION DEFEAT to the PRN41 position AND verifies:
Appendix C                      Job Performance Measure                    Form ES-C-1 PERFORMANCE INFORMATION ER-NIS.3, Att. N-41 Defeat, step 5 4 Performance Step: 5 Place the OVERTEMP TRIP bistable (Red R-1 Protection Channel 1 rack) proving switch to DEFEAT (UP) AND verify the following:
Local light for CHANNEL DEFEAT lower section is lit. Comment: Page 7 of 13 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION 4 Performance Step: 10 Standard:
0  Annunciator F-23, RCS 0T)T CHANNEL ALERT, is lit 0  Proving light OFF if TI-4058 > or = TI-405A IF any proving light status is NOT correct, THEN submit an ACTION Fleport on the discrepancy and continue with the channel defeat steps.
Comment: I/ Performance Step: 11 Standard:
Standard:           Places the OVERTEMP TRIP bistable proving switch to DEFEAT (UP) AND verifies the following:
Comment: 4 Performance Step: 12 Standard:
0  Annunciator F-23,RCS OT delta-T CHANNEL ALERT, is lit 0  Proving light OFF if TI-4058 > or = Ti-405A Comment:
ER-NIS.3, Att. N-41 Defeat, step 10 Place the POWER MISMATCH BYPASS switch (Detector Current CDmparator-Miscellaneous Controls & Indications drawer) tc BYPASS PR N41. Places the POWER MISMATCH BYPASS to BYPASS PR N41. ER-NIS.3, Att. N-41 Defeat, step 11 Place the ROD STOP BYPASS switch (Detector Current Comparator-Miscellaneous Controls & Indications drawer) to BYPASS PR N41. Places the ROD STOP BYPASS switch to BYPASS PR N41. ER-NIS.3, Att. N-41 Defeat, step 12 Place the COMPARATOR CHANNEL DEFEAT switch (Cornparalor and Ratedrawer) to N41 AND verify the following: Local light for COMPARATOR DEFEAT is lit. Places the COMPARATOR CHANNEL DEFEAT switch to N41 AND verifies:
ER-NIS.3, Att. N-41 Defeat, step 6
Local light for COMPARATOR DEFEAT is lit. Comment: Page 8 of 13 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION ER-NIS.3, Att. N-41 Defeat, step 13 N41 B drawer) AND verify the following alarms (MCB) are lit: 4 Performance Step: 13 Remove the 118V 5A AC INSTR POWER fuses (Power Range E-l8, POWER RANGE LOSS OF DETECTOR E-l9, POWER RANGE HI RANGE CHANNEL ALERT 1013% E-21, POWER RANGE OVERPOWER ROD STOP 103% E-27, POWER RANGE LO RANGE CHANNEL ALERT E-;!8, POWER RANGE ROD DROP ROD STOP -5'/0/5 VOLTAGE 24% SEC Standard:
/, Performance Step: 6  Place the OVERPOWER TRIP bistable (Red R-1 Protection Channel 1 rack) proving switch to DEFEAT (UP) AND verify the following:
Removes ,the 118V 5A AC INSTR POWER fuses (Power Range N41 B drawer) AND verifies the following alarms (MCB) are lit: E-1 8, POWER RANGE LOSS OF DETECTOR VOLTAGE E-19, POWER RANGE HI RANGE CHANNEL ALERT 1 Ot3% E-Z!l, POWER RANGE OVERPOWER ROD STOP 103% E-27, POWER RANGE LO RANGE CHANNEL ALERT E-28, POWER RANGE ROD DROP ROD STOP -5%/5 24% SEC Comment: ER-NIS.3, Att. N-41 Defeat, step 13.1 Verify the following red bistable lights (MCB) are lit: Performance Step: 14 HI I'OW RANGE P-10 NC41M HI I'OW RANGE P-8 NC41N LO POW RANGE TRIP NC41P HI POW RANGE TRIP NC41R HI I'OW RANGE P-9 NC41S IF any bistiable above is NOT lit, THEN the channel may not be in the tripped. Standard:
Annunciator F-32,RCS OP delta-T CHANNEL ALERT, is lit 0   Proving light OFF if TI-405B > or = TI-405C IF any proving light status is NOT correct, THEN submit an ACTION Report on the discrepancy and continue with the channel defeat steps.
Verifies the following red bistable lights (MCB) are lit: HI POW RANGE P-10 NC41M HI POW RANGE P-8 NC41N 0 0 LO POW RANGE TRIP NC41 P HI POW RANGE TRIP NC41R HI POW RANGE P-9 NC41S Comment: Page 9 of 13 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION Performance Step: 15 Standard:
4 Standard:           Places the OVERPOWER TRIP bistable proving switch to DEFEAT (IJP) AND verifies the following:
Comment: Performance Step:
0   Anriunciator F-32, RCS OP delta-T CHANNEL ALERT, is lit Proving light OFF if TI-4058 > or = TI-405C Comment:
16 Standard:
Page 6 of 13
ER-NIS.3, Att. N-41 Defeat, step 13.2 Verify the following status lights (Power Range N41A drawer) are lit: 0 CONTROL POWER ON 0 LOSS OF DETECTOR VOLT OVERPOWER TRIP HIGH RANGE OVERPOWER ROD STOP 0 OVERPOWER TRIP LOW RANGE 0 POWER ABOVE PERMISSIVE P10 0 POWER ABOVE PERMISSIVE P8 0 POWER ABOVE PERMISSIVE P9 0 DROPPED ROD ROD STOP 0 DROPPED ROD BYPASS Verifies the following status lights (Power Range N41 A drawer) are lit: CCINTROL POWER ON LOSS OF DETECTOR VOLT 0 OL'ERPOWER TRIP HIGH RANGE OVERPOWER ROD STOP 0 OVERPOWER TRIP LOW RANGE 0 PCIWER ABOVE PERMISSIVE P10 PClWER ABOVE PERMISSIVE P8 0 POWER ABOVE PERMISSIVE P9 DROPPED ROD ROD STOP 0 DROPPED ROD BYPASS ER-NIS.3, Att. N-41 Defeat, step 13.3 Verify the following status lights (Power Range N41 B drawer) are extinguished:
 
INSTRUMENT POWER ON 0 CHANNEL ON TEST Verifies the following status lights (Power Range N41 B drawer) are extinguished:
Appendix C                      Jot) Performance Measure                Form ES-C-1 PERFORMANCE INFORMATION ER-NIS.3, Att. N-41 Defeat, step 7 Performance Step: 7 Verify the following bistables are lit:
0 INSTRUMENT POWER ON CHANNEL ON TEST Comment: Fage 10 of 13 Appendix C Jclb Performance Measure Form ES-C-1 PERFORMANCE INFORMATION ER-NIS.3, Att. N-41 Defeat, step 14 Notify I&C to install jumpers across contacts 1-5 AND 4-8 of Power Range relays NC 41 MX (both A train and B train Protection Racks). This will remove N-41 from the logic circuit for reinstating the PR low power trip and the source ranges (P-10).
: a. TC405A OP Delta T LOODA
Performance Step: 17 Standard:
: b. TC405C OT Delta T Loop A Standard:          Verifies bistables are lit:
Notifies I&C to install jumpers across contacts 1-5 AND 4-8 of Power Range relays NC 41 MX (both A train and B train Protection Racks). CUE: Acknowledge request. Comment: ER-NIS.3, Att. N-41 Defeat, step 15 Performance Step:
: a. TC405A OP Delta T Loop A
18 Initiate an A-52.4 on N-41. Standard:
: b. TC405C OT Delta T Loop A Comment:
CUE: Com ment : Initiates an A-52.4 on N-41 or informs CRS to initiate A-52.4. CRS has initiated an A-52.4 for NI-41.
ER-NIS.3, Att. N-41 Defeat, step 8 4  Performance Step: 8 Place the lJPPER SECTION DEFEAT switch (Detector Current Comparator- Miscellaneous Control & Indications drawer) to the PRN41 position AND verify the following:
ER-NIS.3, Att. N-41 Defeat, step 16 Go to step 4-5. Performance Step:
Local light for CHANNEL DEFEAT upper section is lit.
19 Standard:
Standard:           Places the UPPER SECTION DEFEAT switch to the PRN41 position AND verifies:
Goes to stlzp 4.5. CUE: Comment: CRS will continue at step 4.5. . Terminating Cue: Evaluatiori on this JPM is complete.
Local light for CHANNEL DEFEAT upper section is lit.
STOP TIME: TIME CRITICAL STOP TIME: Page 11 of 13 Appendix C Jclb Performance Measure VERIFICATION OF COMPLETION Form ES-C-1 Job Performance Measure No.: 2008 IWC JPM G Examinee's Name: Date Performed:
Comment:
ER-NIS.3, Att. N-41 Defeat, step 9 4  Performance Step: g Place the LOWER SECTION DEFEAT switch (Detector Current Comparator-MiscellaneousControls & Indications drawer) to the PRN41 position AND verify the following:
Local light for CHANNEL DEFEAT lower section is lit.
Standard:           Places the LOWER SECTION DEFEAT to the PRN41 position AND verifies:
Local light for CHANNEL DEFEAT lower section is lit.
Comment:
Page 7 of 13
 
Appendix C                      Job Performance Measure                  Form ES-C-1 PERFORMANCE INFORMATION ER-NIS.3, Att. N-41 Defeat, step 10 4  Performance Step: 10 Place the POWER MISMATCH BYPASS switch (Detector Current CDmparator-MiscellaneousControls & Indications drawer) tc BYPASS PR N41.
Standard:           Places the POWER MISMATCH BYPASS to BYPASS PR N41.
Comment:
ER-NIS.3, Att. N-41 Defeat, step 11 I/ Performance Step: 11 Place the ROD STOP BYPASS switch (Detector Current Comparator-MiscellaneousControls & Indications drawer) to BYPASS PR N41.
Standard:           Places the ROD STOP BYPASS switch to BYPASS PR N41.
Comment:
ER-NIS.3, Att. N-41 Defeat, step 12 4  Performance Step: 12 Place the COMPARATOR CHANNEL DEFEAT switch (Cornparalor and Ratedrawer) to N41 AND verify the following:
Local light for COMPARATOR DEFEAT is lit.
Standard:            Places the COMPARATOR CHANNEL DEFEAT switch to N41 AND verifies:
Local light for COMPARATOR DEFEAT is lit.
Comment:
Page 8 of 13
 
Appendix C                      Job Performance Measure                      Form ES-C-1 PERFORMANCE INFORMATION ER-NIS.3, Att. N-41 Defeat, step 13 4  Performance Step: 13  Remove the 118V 5A AC INSTR POWER fuses (Power Range N41B drawer) AND verify the following alarms (MCB) are lit:
E-l8, POWER RANGE LOSS OF DETECTOR VOLTAGE E-l9, POWER RANGE HI RANGE CHANNEL ALERT 1013%
E-21, POWER RANGE OVERPOWER ROD STOP 103%
E-27, POWER RANGE LO RANGE CHANNEL ALERT 24%
E-;!8, POWER RANGE ROD DROP ROD STOP -5/0/5 SEC Standard:            Removes ,the 118V 5A AC INSTR POWER fuses (Power Range N41B drawer) AND verifies the following alarms (MCB) are lit:
E-18, POWER RANGE LOSS OF DETECTOR VOLTAGE E-19, POWER RANGE HI RANGE CHANNEL ALERT 1Ot3%
E-Z!l, POWER RANGE OVERPOWER ROD STOP 103%
E-27, POWER RANGE LO RANGE CHANNEL ALERT 24%
E-28, POWER RANGE ROD DROP ROD STOP -5%/5 SEC Comment:
ER-NIS.3, Att. N-41 Defeat, step 13.1 Performance Step: 14 Verify the following red bistable lights (MCB) are lit:
HI IOW RANGE P-10 NC41M HI IOW RANGE P-8 NC41N LO POW RANGE TRIP NC41P HI POW RANGE TRIP NC41R HI IOW RANGE P-9 NC41S IF any bistiable above is NOT lit, THEN the channel may not be in the tripped.
Standard:           Verifies the following red bistable lights (MCB) are lit:
HI POW RANGE P-10 NC41M HI POW RANGE P-8 NC41N 0  LO POW RANGE TRIP NC41P 0  HI POW RANGE TRIP NC41R HI POW RANGE P-9 NC41S Comment:
Page 9 of 13
 
Appendix C                        Job Performance Measure                  Form ES-C-1 PERFORMANCE INFORMATION ER-NIS.3, Att. N-41 Defeat, step 13.2 Performance Step: 15  Verify the following status lights (Power Range N41A drawer) are lit:
0    CONTROL POWER ON 0    LOSS OF DETECTOR VOLT OVERPOWER TRIP HIGH RANGE OVERPOWER ROD STOP 0    OVERPOWER TRIP LOW RANGE 0    POWER ABOVE PERMISSIVE P10 0    POWER ABOVE PERMISSIVE P8 0    POWER ABOVE PERMISSIVE P9 0    DROPPED ROD ROD STOP 0    DROPPED ROD BYPASS Standard:             Verifies the following status lights (Power Range N41A drawer) are lit:
CCINTROL POWER ON LOSS OF DETECTOR VOLT 0    OLERPOWER TRIP HIGH RANGE OVERPOWER ROD STOP 0   OVERPOWER TRIP LOW RANGE 0    PCIWER ABOVE PERMISSIVE P10 PClWER ABOVE PERMISSIVE P8 0  POWER ABOVE PERMISSIVE P9 DROPPED ROD ROD STOP 0  DROPPED ROD BYPASS Comment:
ER-NIS.3, Att. N-41 Defeat, step 13.3 Performance Step: 16  Verify the following status lights (Power Range N41B drawer) are extinguished:
INSTRUMENT POWER ON 0   CHANNEL ON TEST Standard:            Verifies the following status lights (Power Range N41B drawer) are extinguished:
0   INSTRUMENT POWER ON CHANNEL ON TEST Comment:
Fage 10 of 13
 
Appendix C                          Jclb Performance Measure                  Form ES-C-1 PERFORMANCE INFORMATION ER-NIS.3, Att. N-41 Defeat, step 14 Performance Step: 17    Notify I&C to install jumpers across contacts 1-5 AND 4-8 of Power Range relays NC 41 MX (both A train and B train Protection Racks). This will remove N-41 from the logic circuit for reinstating the PR low power trip and the source ranges (P-10).
Standard:               Notifies I&C to install jumpers across contacts 1-5 AND 4-8 of Power Range relays NC 41 MX (both A train and B train Protection Racks).
CUE:     Acknowledge request.
Comment:
ER-NIS.3, Att. N-41 Defeat, step 15 Performance Step: 18    Initiate an A-52.4 on N-41.
Standard:                Initiates an A-52.4 on N-41 or informs CRS to initiate A-52.4.
CUE:     CRS has initiated an A-52.4 for NI-41.
Comment:
ER-NIS.3, Att. N-41 Defeat, step 16 Performance Step: 19    Go to step 4-5.
Standard:               Goes to stlzp 4.5.
CUE:     CRS will continue at step 4.5.
Comment:
. Terminating Cue:            Evaluatiori on this JPM is complete.
STOP TIME:                                    TIME CRITICAL STOP TIME:
Page 11 of 13
 
Appendix C                      Jclb Performance Measure      Form ES-C-1 VERIFICATION OF COMPLETION Job Performance Measure No.:  2008 I W C JPM G Examinees Name:
Date Performed:
Facility Evaluator:
Facility Evaluator:
Number of Attempts:
Number of Attempts:
Line 532: Line 1,045:
Question Documentation:
Question Documentation:
Question:
Question:
Response:
 
Result: SAT UNSAT Examiner's Signature: Date:
===Response===
F'age 12 of 13
Result:                     SAT               UNSAT Examiners Signature:                                   Date:
- Appendix C Jab Performance Measure Form ES-C-1 JPM CUE SHEET Initial Conditions:
Fage 12 of 13
You are an extra RO. 0 Power Range channel N-41 drifted low over a period of several minutes and has been declared inoperable.
 
0 No plant t ?ansient has occurred.
Appendix C                         Jab Performance Measure                   Form ES-C-1 JPM CUE SHEET Initial Conditions:         You are an extra RO.
0 Procedure ER-NIS.3 is being implemented.
0   Power Range channel N-41 drifted low over a period of several minutes and has been declared inoperable.
Reactor pDwer is 100&deg;/o. 0 No other channels have been defeated.
0   No plant t ?ansienthas occurred.
Initiating Cue: The CRS has directed you to remove PR N-41 from service per ER- NIS.3. Step 4.4 Attachment N-41 Defeat. All notifications have been made and approvals received.
0   Procedure ER-NIS.3 is being implemented.
Page 13 of 13 Appendix C Job Performance Measure Form ES-C-1 Worksheet Facility:
Reactor pDwer is 100&deg;/o.
TasWJPM Title: WA  
0   No other channels have been defeated.
Initiating Cue:     The CRS has directed you to remove PR N-41 from service per ER-NIS.3.
Step 4.4 Attachment N-41 Defeat.
All notifications have been made and approvals received.
Page 13 of 13
 
Appendix C                           Job Performance Measure               Form ES-C-1 Worksheet Facility:           Ginna                              Task No.:  029-004-01-01A TasWJPM
 
==Title:==
Shutdown Containment Purge        JPM No.:    2008 NRC JPM H WA  


==Reference:==
==Reference:==
APE 036 AA1.O1      3.313.8 Examinee:                                            NRC Examiner:
Facility Evaluator:                                  Date:
Method of testina:
Simulated Performance:                              Actual Performance:    X Classroom          Simulator    X    Plant Applicability: RO/SRO SUBMITTED BY:                      Ted Coe                      DATE:    6/30/08 Developer REVIEWED BY:                      Art Vest                    DATE:    6/30/08 Training Technical Reviewer REVIEWED BY:                    Don Dettman                    DATE:    6/30/08 Operations Technical Reviewer APPROVED BY:                    John Brown                    DATE:    6/30/08 Training Management Page 1 of 7


Examinee:
vdix C                               Job Performance Measure                       Form ES-C-1 Worksheet Task Standard:             The Containmerit Purge shutdown and all critical tasks evaluated as satisfactory.
Facility Evaluator:
Required Materials:         None General  
Method of testina: Ginna Task No.: 029-004-01
-01 A Shutdown Containment Purge JPM No.: 2008 NRC JPM H APE 036 AA1.O1 3.313.8 NRC Examiner:
Date: Simulated Performance:
Actual Performance:
X Classroom Simulator X Plant Applicability:
RO/SRO SUBMITTED BY: Ted Coe DATE: 6/30/08 Developer REVIEWED BY: Art Vest DATE: 6/30/08 Training Technical Reviewer REVIEWED BY: Don Dettman DATE: 6/30/08 Operations Technical Reviewer APPROVED BY: John Brown DATE: 6/30/08 Training Management Page 1 of 7 vdix C Job Performance Measure Worksheet Form ES-C-1 Task Standard:
The Containmerit Purge shutdown and all critical tasks evaluated as satisfactory.
Required Materials: None General  


==References:==
==References:==
S-23.2.2,        Containment Purge Procedure, Rev. 04801 Handouts:                  S-23.2.2, Containment Purge Procedure, Rev. 04801 Time Critical Task:        NO Validation Time:            5 minutes Alternate Path:            NO Instructor Notes:          Ensure a marked up copy of S-23.2.2,    Containment Purge Procedure, Rev. 04801 is rea.dy to give to the operator during the Initiating Cue.
READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
Initial Conditions:                You are an extra RO.
The plant is in cold shutdown.
0  A Containment Purge is in progress.
The Refuel SRO has requested Containment Purge be secured due to a Rt?fuelingIncident.
RP has authorized securing the purge.
Initiating Cue:            The Shift Manager directs you to secure the Containment Purge per Step 6.3of S-23.2.2.
CUE: Hand the Operator a marked up (copyof S-23.2.2, Containment Purge Procedure, Rev. 04801.
Page 2 of 7


S-23.2.2, Containment Purge Procedure, Rev. 04801 Handouts:
Appendix C                             Job Performance Measure Form ES-C-1 Worksheet
S-23.2.2, Containment Purge Procedure, Rev. 04801 Time Critical Task: NO Validation Time: 5 minutes Alternate Path:
                                      -SIMIULATOR SETUP For the 2008 ILT NRC Exam load I/C ## 178 or 0   Any cold shutdown IC.
NO Instructor Notes: Ensure a marked up copy of S-23.2.2, Containment Purge Procedure, Rev. 04801 is rea.dy to give to the operator during the Initiating Cue. READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
0   Remove purge flanges, MIS78.
Initial Conditions:
0   Place purge system in service with both fans running.
You are an extra RO. The plant is in cold shutdown.
0   S-23.2.2 signed off up to section 6.3.
0 A Containment Purge is in progress.
Page 3 of 7
The Refuel SRO has requested Containment Purge be secured due to a Rt?fueling Incident.
 
RP has authorized securing the purge. Initiating Cue: The Shift Manager directs you to secure the Containment Purge per Step 6.3 of S-23.2.2.
Appendix C                     Joo Performance Measure                 Form ES-C-1 PERFORMANCE INFORMATION START TIME:
CUE: Hand the Operator a marked up (copy of S-23.2.2, Containment Purge Procedure, Rev. 04801. Page 2 of 7 Appendix C Job Performance Measure Worksheet Form ES-C SI MI U LATOR SETUP For the 2008 ILT NRC Exam load I/C ## 178 or 0 Any cold shutdown IC. 0 Remove purge flanges, MIS78. 0 Place purge system in service with both fans running. 0 S-23.2.2 signed off up to section 6.3. Page 3 of 7 Appendix C Joo Performance Measure Form ES-C-1 PERFORMANCE INFORMATION START TIME: d = CRITICAL STEP 4 Performance Step:
d = CRITICAL STEP S-23.2.2, step 6.3.1 4  Performance Step: 1 STOP Containment Purge Supply and Exhaust Fans A if running. OTHERWISE MARK this step N/A.
1 Standard:
Standard:          Switch to stop. Red lights off, Green lights on.
Comment: 4 Performance Step: 2 Standard:
Comment:
Comment: 4 Performance step: 3 Standard:
S-23.2.2, step 6.3.2 4  Performance Step: 2 STOP Containment Purge Supply and Exhaust Fans B if running OTHERWISE MARK this step N/A.
Comment: 4 Performance Step: 4 Standard:
Standard:          Switch to stop. Red lights off, Green lights on.
Comment: S-23.2.2, step 6.3.1 STOP Containment Purge Supply and Exhaust Fans "A if running. OTHERWISE MARK this step N/A. Switch to stop. Red lights off, Green lights on. S-23.2.2, step 6.3.2 STOP Containment Purge Supply and Exhaust Fans "B if running OTHERWISE MARK this step N/A. Switch to stop. Red lights off, Green lights on. S-23.2.2, step 6.3.4 CLOSE Containment Purge Supply Valve V-5869. Switch to c:lose. Red light off, Green light on. S-23.2.2, step 6.3.4 CLOSE Cclntainment Purge Exhaust Valve V-5879. Switch to close.
Comment:
Red light off, Green light on. Page 4 of 7 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION S-23.2.2, step 6.3.5 LOG information on Containment Purge Release Permit. Performance Step:
S-23.2.2, step 6.3.4 4  Performance step: 3 CLOSE Containment Purge Supply Valve V-5869.
5 Standard:
Standard:          Switch to c:lose. Red light off, Green light on.
CUE: Comment: Logs information on Containment Purge Release Permit.
Comment:
The HCO will do that. Terminating Cue: Evaluation on this JPM is complete.
S-23.2.2, step 6.3.4 4  Performance Step: 4 CLOSE Cclntainment Purge Exhaust Valve V-5879.
STOP TIME: TIME CRITICAL STOP TIME:
Standard:          Switch to close. Red light off, Green light on.
Page 5 of 7 Appendix C Job Performance Measure Form ES-C-1 VERIFICATION OF COMPLETION Job Performance Measure No.: Examinee's Name: 2008 NRC JPM H Date Performed:
Comment:
Page 4 of 7
 
Appendix C                       Job Performance Measure                 Form ES-C-1 PERFORMANCE INFORMATION S-23.2.2, step 6.3.5 Performance Step: 5    LOG information on Containment Purge Release Permit.
Standard:               Logs information on Containment Purge Release Permit.
CUE:    The HCO will do that.
Comment:
Terminating Cue:           Evaluation on this JPM is complete.
STOP TIME:                                 TIME CRITICAL STOP TIME:
Page 5 of 7
 
Appendix C                       Job Performance Measure       Form ES-C-1 VERIFICATION OF COMPLETION Job Performance Measure No.: 2008 NRC JPM H Examinees Name:
Date Performed:
Facility Evaluator:
Facility Evaluator:
Number of Attempts:
Number of Attempts:
Time to Complete: Question Documentation:
Time to Complete:
Question Documentation:
Question:
Question:
Response:
 
Result: UNSAT -- SAT Examiner's Signature:
===Response===
Date: Page 6 of 7 Appendix C Job Performance Measure JPM CUE SHEET Form ES-C-1 Initial Conditions:
Result:                     SAT              UNSAT Examiners Signature:                                   Date:
You are an extra RO. The plant is in cold shutdown.
Page 6 of 7
 
Appendix C                         Job Performance Measure                 Form ES-C-1 JPM CUE SHEET Initial Conditions:       You are an extra RO.
The plant is in cold shutdown.
A Containment Purge is in progress.
A Containment Purge is in progress.
0 The Refuc?i SRO has requested Containment Purge be secured due to a Flefueling incident.
0   The Refuc?iSRO has requested Containment Purge be secured due to a Flefueling incident.
RP has authorized securing the purge. initiating Cue: The Shift Manager directs you to secure the Containment Purge per Step 6.3 of S-232.2. Page 7 of 7 Appendix C Job Performance Measure Worksheet Form ES-C-1 Facility: Ginna  
RP has authorized securing the purge.
~ Task No.: 001 -007-01 -04A Task/JPM Title: Startup and Parallel Rod Drive MG JPM No.: 2008 NRC JPM I Set (Parallel Fails) WA  
initiating Cue:     The Shift Manager directs you to secure the Containment Purge per Step 6.3 of S-232.2.
Page 7 of 7
 
Appendix C                             Job Performance Measure                 Form ES-C-1 Worksheet                              ~
Facility:           Ginna                                   Task No.:   001-007-01-04A Task/JPM
 
==Title:==
Startup and Parallel Rod Drive MG       JPM No.:   2008 NRC JPM I Set (Parallel Fails)
WA  


==Reference:==
==Reference:==
001 A4.0 8 3.7 / :3.4 Examinee:
001 A4.0 8     3.7 / :3.4 Examinee:                                               NRC Examiner:
NRC Examiner:
Facility Evaluator:                                     Date:
Facility Evaluator: Date:
Method of testing:
Method of testing: Simulated Performance:
Simulated Performance:     X                           Actual Performance:
X Actual Performance: Classroom Simulator Plant X Applicability:
Classroom             Simulator             Plant       X Applicability: RO/SRO SUBMITTED BY:                       Ted Coe                       DATE:     6/30/08 Developer REVIEWED BY:                       Art Vest                       DATE:     6/30/08 Training Technical Reviewer REVIEWED BY:                     Don Dettman                       DATE:     6/30/08 Operations Technical Reviewer APPROVED BY:                   John Brown                         DATE:     6/30/08 Training Management Page 1 of 13
RO/SRO SUBMITTED BY: Ted Coe DATE: 6/30/08 Developer REVIEWED BY: Art Vest DATE: 6/30/08 Training Technical Reviewer REVIEWED BY: Don Dettman DATE: 6/30/08 Operations Technical Reviewer APPROVED BY: John Brown DATE: 6/30/08 Training Management Page 1 of 13 Appendix C Job Performance Measure Worksheet Form ES-C-1 Task Standard:
 
Required Materials:
Appendix C                                   Job Performance Measure                     Form ES-C-1 Worksheet Task Standard:             MG sets paralleled and all critical tasks evaluated as satisfactory.
MG sets paralleled and all critical tasks evaluated as satisfactory. Proper Noise Protection, Hard Hat, Safety Glasses, Safety Shoes, Leather Gloves.
Required Materials:          Proper Noise Protection, Hard Hat, Safety Glasses, Safety Shoes, Leather Gloves.
S-1 A, Startup of Fbd Drive Motor Generator Sets, Rev. 18 S-1 A, Startup of Rod Drive Motor Generator Sets, Rev.18 General  
General  


==References:==
==References:==
S-1A, Startup of Fbd Drive Motor Generator Sets, Rev.18 Handouts:                    S-1A, Startup of Rod Drive Motor Generator Sets, Rev.18 Time Critical Task:          NO Validation Time:            20 minutes Alternate Path:              YES Instructor Notes:            Ensure Proper IJoke Protection, Hard Hat, Safety Glasses, Safety Shoes and leather gloves are worn as required.
Ensure a marked up copy of S-1A, Startup of Rod Drive Motor Generator Sets, Rev.18 is ready to give to the operator during the Initiating Cue.
READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
Initial Conditions:        0    You are an extra RO.
0    Preparations fw startup of Rod Control System are under way.
The 18 MG set is running.
Initiating Cue:            The Shift Manager directs you to startup and parallel the 1A Rod Drive MG Set per S-1A section 5.3.
Simulate all activities - DO NOT MANIPULATE ANY EQUIPMENT.
CUE: Hand the Operator a marked up copy of S-1A, Startup of Rod Drive Motor Generator Sets, Rev.18.
Page 2 of 13
                                                                              ~
Appendix C                          Job Performance Measure                      Form ES-C-1 PERFORMANCE INFORMATION START TIME:
4 = CRITICAL STEP S-1A, step 5.3.1 Performance Step: 1    One MG set is running and carrying a steady electrical load.
Standard:              Verifies 1E3 MG set is running. Given in initial cue.
CUE:    1B MG set is running, carrying a steady electrical load. 1A MG set is secured, Comment:
S-1A, step 5.3.2 Performance step: 2    Verify remaining motor generator set ALARM BYPASS switch is in the BYPASS position.
Standard:              Verifies 1A MG set ALARM BYPASS switch is in the BYPASS position.
CUE:    1A MG set ALARM BYPASS switch is in the BYPASS position.
Comment:
S-1A, step) 5.3.3 Performance Step: 3    Verify the remaining Motor Generator set VOLTAGE ADJUST in full counter-clockwise position.
Standard:                1A MG set VOLTAGE ADJUST is in full counter-clockwise position.
CUE:    1A MG set VOLTAGE ADJUST is in full counter-clockwise position.
Comment:
S-1 A, step 5.3.4.1
/,  Performance Step: 4    Rotate the MOTOR NO. 1A CIRCUIT BREAKER CONTROL switch to CLOSE.
Standard:              Identifies the MOTOR NO. 1A CIRCUIT BREAKER CONTROL switch, and simulates rotating to CLOSE.
CUE:    Component is in desired position.
Comment:
Page 3 of 13
Appendix C                            Job Performance Measure                  Form ES-C-1 PERFORMANCE INFORMATION CUE:        Motor is at full speed.
S-lA, step 5.3.4.2
/,  Performance Step: 5      WHEN motor is at full speed, THEN depress AND hold the FIELD FLASH pushbutton.
Standard:                Identifies FIELD FLASH pushbutton, and generator voltage indication (OUTPUT AC VOLTAGE METER).
Simulate depressing and holding FIELD FLASH pushbutton.
CUE:    Component is in desired condition.
Comment:
S-1A, step 5.3.4.3
,,/ Performance step: 6      WHEN Gmerator voltage has risen to > 234 volts AND is NOT increasing, THEN release the FIELD FLASH pushbutton.
Standard:                Simulates FIELD FLASH pushbutton released.
CUE:    Generator voltage has risen to 250 volts AND is steady.
CUE:      Component is in desired condition.
Comment:
S-1A, step 5.3.4.4
/,  Performance step: 7      Rotate the VOLTAGE ADJUST potentiometer clockwise UNTIL voltage is 260.
Standard:                Rotates the VOLTAGE ADJUST potentiometer clockwise UNTIL voltage is ;!60.
CUE:      Generator voltage has risen slowly to 260 volts.
Comment:
S-1A, step 5.3.5 Performance step: 8      Verify FIELD CURRENT is ~ 1 . amps 2 AND ~ 4 . amps 8    as read on the FIELD CURRENT METER.
Standard:                Identifies FIELD CURRENT METER.
CUE:      FIELD CURRENT is as read.
Comment:
Page 4 of 13
Appendix C                          Job Performance Measure                  Form ES-C-1 PERFORMANCE INFORMATION S-1A, step 5.3.6 Performance Step: g    Verify FIELD CURRENT alarm has cleared. (Alarm LED is located or1 the FIELD CURRENT METER)
Standard:              Identifies alarm LED on the FIELD CURRENT METER is out.
CUE:    Alarm LED on the FIELD CURRENT METER is out.
Comment:
S-1A, step 5.3.7 Performance Step: 10    Place ALARM BYPASS switch in the "ACTIVE position.
Standard:                Identifies ALARM BYPASS switch and simulates placing in "ACTIVE",
CUE:    Component is in desired position.
Comment:
S-1A, step 5.3.8 Performance step: 11    Verify MC13 annunciator C-21 (Rod Control MG Set Trouble) is extinguished.
Standard:                Contacts control room on status of (3-21.
CUE:      C-21, (Rod Control MG Se!t Trouble) is extinguished.
Comment:
S-1A, step 5.3.9
/, Performance Step: 12    Rotate the synchronize switch to ON (on the MG set being started) AND allow a few seconds for the synchronizer to warm UP-Standard:                Rotates tht? 1A synchronize switch to ON (AND allows a few seconds for the synchronizer to warm up.
CUE:      Component is in desired position.
Comment:
Page 5 of 13
Appendix C                            Jcb Performance Measure                    Form ES-C-1 PERFORMANCE INFORMATION S-1A, step 5.3.10.1
/,  Performance Step: 13    Observe tne Synchroscope (Syn/CRDMGAB) for indication when the two generators are in sync and trip the on-coming M/G Set Motor Breaker by rotating the circuit breaker control handle to the TRIP POSITION just after the Synchronizing Point (approximately 3 minutes after 12).
Standard:                Observes the Synchroscope for indication when the two generators are in sync and trips the 1A M/G Set Motor Breaker by rotating the circuit breaker control handle to the TRIP POSITION just after the Synchronizing Point (approximately 3 minutes after 12).
CUE:    Component is in desired position.
CUE:    It has been 30 seconds and the Synchroscope indicates the two generators are not in parallel.
Comment:
S-1A, step 5.3.1 0.2
/, Performance step; 14      Should the Generator fail to parallel within 30 seconds, THEN return the synchronize switch to OFF, AND proceed with steps 5.3.1 through 5.3.10 again. N/A if generator paralleled.
Standard:                Synchroniiie switch to OFF.
Returns to step 5.3.1.
CUE:    Synchroscope indicates tlhe two generators are not in parallel.
CUE:    Component is in desired position.
Comment :
S-1A, step 5.3.1 (Start Alternate Path)
Performance Step: 15      One MG set is running and carrying a steady electrical load.
Standard:                Verifies 19 MG set is running. Given in initial cue.
CUE:      1B MG set is running, carrying a steady electrical load.
Comment:
S-1A, step 5.3.2 Performance Step: 16      Verify remaining motor generator set ALARM BYPASS switch is in the BYPASS position.
Standard:                  Places 1A bAG set ALARM BYPASS switch in the BYPASS position.
CUE:      1A MG set ALARM BYPAS!3 switch is in the BYPASS position.
Page 6 of 13
Appendix C                          Job Performance Measure                    Form ES-C-1 PERFORMANCE INFORMATION Comment:
S-1A, step 5.3.3 Performance step: 17    Verify the remaining Motor Generator set VOLTAGE ADJUST in full counter-clockwise position.
Standard:                Adjusts 1A MG set VOLTAGE ADJUST to the full counter-clockwise position.
CUE:    1A MG set VOLTAGE AD,IUST is in full counter-clockwise position.
Comment:
S-1A, step 5.3.4.1
,/ Pedormance step: 18      Rotate the MOTOR NO. 1A CIRCUIT BREAKER CONTROL switch to CLOSE.
Standard:                Identifies switch, and simulate rotating to CLOSE.
CUE:    Component is in desired position.
Comment:
CUE:      Motor is at full speed.
S-1A, step 5.3.4.2
,/ Performance Step: 19      WHEN motor is at full speed, THEN depress AND hold the FIELD FLASH pushbutton.
Standard:                Identifies FIELD FLASH pushbutton, and generator voltage indication (OUTPUT AC VOLTAGE METER).
Simulate depressing and holding FIELD FLASH pushbutton.
CUE:      Component is in desired condition.
Comment:
S-1A, step 5.3.4.3
/,  Performance step: 20    WHEN Generator voltage has risen to > 234 volts AND is NOT increasing, THEN release the FIELD FLASH pushbutton.
Standard:                Simulates FIELD FLASH pushbutton released.
CUE:    Generator voltage has risen to 250 volts AND is steady.
CUE:    Component is in desired condition.
Comment:
Page 7 of 13
Appendix C                        Job Performance Measure                Form ES-C-1 PERFORMANCE INFORMATION S-1A, step 5.3.4.4
/,  Performance Step: 21  Rotate the VOLTAGE ADJUST potentiometer clockwise UNTIL voltage is 260.
Standard:              Rotates the VOLTAGE ADJUST potentiometer clockwise UNTIL voltage is 260.
CUE:    Generator voltage has risen slowly to 260 volts.
Comment:
S-1A, stelp 5.3.5 Performance Step: 22  Verify FIELD CURRENT is >1.2 amps AND c4.8 amps as read on the FlEiLD CURRENT METER.
Standard:              Identifies FIELD CURRENT METER.
CUE:    FIELD CURRENT is as read.
Comment:
S-1A, step 5.3.6 Performance step: 23  Verify FIELD CURRENT alarm has cleared. (Alarm LED is located or the FIELD CURRENT METER)
Standard:              Identifies alarm LED on the FIELD CURRENT METER is out.
CUE:    Alarm LED on the FIELD CURRENT METER is out.
Comment:
S-1A, step 5.3.7 Performgnce Step: 24  Place ALARM BYPASS switch in the "ACTIVE position.
Standard:              Identifies ALARM BYPASS switch and simulates placing in "ACTIVE".
CUE:    Component is in desired position.
Comment:
Page 8 of 13


Handouts:
Appendix C                        Job Performance Measure                      Form ES-C-1 PERFORMANCE INFORMATlON S-1 A, step 5.3.8 Performance Step: 25  Verify MCB annunciator C-21 (Rod Control MG Set Trouble) is extinguished.
Time Critical Task: NO Validation Time: 20 minutes Alternate Path: YES Instructor Notes: Ensure Proper I Joke Protection, Hard Hat, Safety Glasses, Safety Shoes and leather gloves are worn as required.
Standard:             Contacts control room on status of C-21.
Ensure a marked up copy of S-1 A, Startup of Rod Drive Motor Generator Sets, Rev.18 is ready to give to the operator during the Initiating Cue. READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
CUE:    C-21, (Rod Control MG Set Trouble) is extinguished.
Initial Conditions:
Comment:
0 You are an extra RO. 0 Preparations f'w startup of Rod Control System are under way. The "18" MG set is running. Initiating Cue: The Shift Manager directs you to startup and parallel the 1A Rod Drive MG Set per S-1A section 5.3. Simulate all activities - DO NOT MANIPULATE ANY EQUIPMENT.
S-1A, step 5.3.9
CUE: Hand the Operator a marked up copy of S-1 A, Startup of Rod Drive Motor Generator Sets, Rev.18. Page 2 of 13 Appendix C ~ Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION START TIME:
/, Performance Step: 26  Rotate the synchronize switch to ON (on the MG set being started) AND allow a few seconds for the synchronizer to warm UP-Standard:             Rotates the 1A synchronize switch to ON (AND allows a few seconds for the synchronizer to warm up.
4 = CRITICAL STEP S-1 A, step 5.3.1 One MG set is running and carrying a steady electrical load. Performance Step: 1 Standard:
CUE:    Component is in desired position.
CUE: Comment: Verifies 1E3 MG set is running. Given in initial cue. 1B MG set is running, carrying a steady electrical load. 1A MG set is secured, S-1 A, step 5.3.2 Verify remaining motor generator set ALARM BYPASS switch is in the "BYPASS position.
Comment:
Performance step: 2 Standard:
S-1 A, step 5.3.10.1 4 Performance step: 27  Observe the Synchroscope (SynKRDMGAB) for indication when the two generators are in sync and trip the on-coming M/G Set Motor Breaker by rotating the circuit breaker control handle to the TRIP POSITION just after the Synchronizing Point (approximately 3 minutes after 12).
CUE: Comment: Verifies 1A MG set ALARM BYPASS switch is in the "BYPASS" posit ion. 1A MG set ALARM BYPASS switch is in the "BYPASS" position.
Standard:             Observes the Synchroscope for indication when the two generators are in sync and trips the 1A M/G Set Motor Brealker by rotating the circuit breaker control handle to the TRIP POSllnONjust after the Synchronizing Point (approximately 3 minutes after 12).
S-1 A, step) 5.3.3 Verify the remaining Motor Generator set VOLTAGE ADJUST in full counter-clockwise position.
CUE:    Component is in desired position.
Performance Step: 3 Standard:
CUE:     Synchroscope indicates the two generators are in parallel.
CUE: Comment: 1A MG set VOLTAGE ADJUST is in full counter-clockwise position.
Comment:
1A MG set VOLTAGE ADJUST is in full counter-clockwise position.
fage 9 of 13
S-1 A, step 5.3.4.1 ,/ Performance Step: 4 Rotate the MOTOR NO. 1A CIRCUIT BREAKER CONTROL switch to CLOSE. Standard:
 
Identifies the MOTOR NO. 1A CIRCUIT BREAKER CONTROL switch, and simulates rotating to CLOSE. CUE: Comment: Component is in desired position.
Appendix C                          Jab Performance Measure                    Form ES-C-1 PERFORMANCE INFORMATION S-1A, step 5.3.10.2 (End Alternate Path)
Page 3 of 13 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE IN FOR MATI ON CUE: Motor is at full speed. S-lA, step 5.3.4.2 WHEN motor is at full speed, THEN depress AND hold the FIELD FLASH pushbutton.  
Performance Step: 28    Should the Generator fail to parallel within 30 seconds, THEN return the synchronize switch to OFF, AND proceed with steps 5.3.1 through 5.3.10again. N/A if generator paralleled.
,/ Performance Step: 5 Standard:
Standard:               Synchronize switch in on.
Identifies FIELD FLASH pushbutton, and generator voltage indication (OUTPUT AC VOLTAGE METER). Simulate depressing and holding FIELD FLASH pushbutton.
Step N/Ad.
CUE: Comment: Component is in desired condition.
CUE:     Synchroscope indicates the two generators are in parallel.
S-1 A, step 5.3.4.3 WHEN Gmerator voltage has risen to > 234 volts AND is NOT increasing, THEN release the FIELD FLASH pushbutton.
Comment:
,,/ Performance step: 6 Standard:
S-1A, step 5.3.1 0.3 Performance Step: 29    Turn the Synchronize switch to the OFF position.
CUE: CUE: Comment: Simulates FIELD FLASH pushbutton released.
Standard:               Synchronize switch in the OFF position.
Generator voltage has risen to 250 volts AND is steady. Component is in desired condition.
CUE:     Component is in desired Iposition.
S-1 A, step 5.3.4.4 Rotate the VOLTAGE ADJUST potentiometer clockwise UNTIL voltage is 260. ,/ Performance step: 7 Standard:
Comment:
Rotates the VOLTAGE ADJUST potentiometer clockwise UNTIL voltage is ;!60. CUE: Comment: Generator voltage has risen slowly to 260 volts. S-1 A, step 5.3.5 Performance step: 8 Verify FIELD CURRENT is ~1.2 amps AND ~4.8 amps as read on the FIELD CURRENT METER.
S-1A, step 5.3.1 1 Performance step: 30    Verify ROII DRIVE M-G SET 1A (MCB center section) red status light is lit.
Standard:
Standard:              Calls Contirol Room to verify ROD DRIVE M-G SET 1A red status light is lit.
Identifies FIELD CURRENT METER.
CUE:      From Control Room, ROD DRIVE M-G SET 1A red status light is lit.
CUE: Comment: FIELD CURRENT is as read. Page 4 of 13 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION S-1 A, step 5.3.6 Verify FIELD CURRENT alarm has cleared. (Alarm LED is located or1 the FIELD CURRENT METER) Performance Step: g Standard:
Comment:
CUE: Comment: Identifies alarm LED on the FIELD CURRENT METER is out. Alarm LED on the FIELD CURRENT METER is out. S-1 A, step 5.3.7 Performance Step: 10 Place ALARM BYPASS switch in the "ACTIVE position.
S-lA, step 5.3.12 Performance step: 31    Verify ROC) DRIVE M-G SET 16 (MCB center section) red status light is lit.
Standard:
Standard:               Calls Control Room to verify ROD DRIVE M-G SET 1B red status light is lit.
CUE: Comment: Identifies ALARM BYPASS switch and simulates placing in "ACTIVE", Component is in desired position.
CUE:     From Control Room, ROD DRIVE M-G SET 1B red status light is lit.
S-1 A, step 5.3.8 Verify MC13 annunciator C-21 (Rod Control MG Set Trouble) is extinguished. Performance step:
Comment:
11 Standard:
F'age 10 of 13
CUE: Comment: Contacts control room on status of (3-21.
 
C-21, (Rod Control MG Se!t Trouble) is extinguished.
Appendix C                        Job Performance Measure                  Form ES-C-1 PERFORMANCE INFORMATION S-1A, step 5.3.13
S-1 A, step 5.3.9 Rotate the synchronize switch to ON (on the MG set being started) AND allow a few seconds for the synchronizer to warm UP- ,/ Performance Step: 12 Standard:
/,  Performance Step: 32  Adjust MG1A and MG1B voltages to minimize MG CIRCULATING CURRENT (indicated on CIRCULATING CURRENT METER) with MG OUTPUT AC VOLTAGE close to 260 volts (between 250 and 270 volts) and FIELD CURRENT
Rotates tht? 1A synchronize switch to ON (AND allows a few seconds for the synchronizer to warm up. CUE: Comment: Component is in desired position.
                          ~ 1 . amps 2    and <4.8 amps on both MGs.
Page 5 of 13 Appendix C Jcb Performance Measure Form ES-C-1 PERFORMANCE INFORMATION S-1 A, step 5.3.1 0.1 Observe tne Synchroscope (Syn/CRDMGAB) for indication when the two generators are in sync and trip the on-coming M/G Set Motor Breaker by rotating the circuit breaker control handle to the TRIP POSITION just after the Synchronizing Point (approximately 3 minutes after 12). ,/ Performance Step: 13 Standard: Observes the Synchroscope for indication when the two generators are in sync and trips the 1A M/G Set Motor Breaker by rotating the circuit breaker control handle to the TRIP POSITION just after the Synchronizing Point (approximately 3 minutes after 12). CUE: CUE: Comment: Component is in desired position.
Standard:              MG OUTPUT AC VOLTAGE close to 260 volts (between 250 and 270 volts) and FIELD CURRENT >1.2 amps and c4.8 amps on both MGs.
It has been 30 seconds and the Synchroscope indicates the two generators are not in parallel.
Records Ckulating Current.
S-1 A, step 5.3.1 0.2 Should the Generator fail to parallel within 30 seconds, THEN return the synchronize switch to OFF, AND proceed with steps 5.3.1 through 5.3.10 again. N/A if generator paralleled.
CUE:   CIRCULATING CURRENT is as read.
,/ Performance step; 14 Standard: Synchroniiie switch to OFF. CUE: CUE: Comment : Returns to step 5.3.1. Synchroscope indicates tlhe two generators are not in parallel.
Comment:
Component is in desired position.
S-1A, step 5.3.14 Performance Step: 33  Verify MCB annunciator C-21 (Rod Control MG Set Trouble) is extinguished.
S-1 A, step 5.3.1 (Start Alternate Path) One MG set is running and carrying a steady electrical load. Performance Step: 15 Standard:
Standard:             Contacts control room on status of C-21.
CUE: Comment: Verifies 19 MG set is running. Given in initial cue. 1 B MG set is running, carrying a steady electrical load. S-1 A, step 5.3.2 Verify remaining motor generator set ALARM BYPASS switch is in the "BYPASS position.
CUE:   C-21, (Rod Control MG Set Trouble) is extinguished.
Performance Step: 16 Standard:
Comment:
CUE: Places 1A bAG set ALARM BYPASS switch in the "BYPASS" position.
Terminating Cue:           Evaluation on this JPM is complete.
1 A MG set ALARM BYPAS!3 switch is in the "BYPASS" position.
STOP TIME:                               TIME CRITICAL STOP TIME:
Page 6 of 13 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION Comment: S-1 A, step 5.3.3 Verify the remaining Motor Generator set VOLTAGE ADJUST in full counter-clockwise position. Performance step:
Page 11 of 13
17 Standard:
 
Adjusts 1A MG set VOLTAGE ADJUST to the full counter- clockwise position.
Appendix C                       Job Performance Measure      Form ES-C-1 VERIFICATION OF COMPLETION Job Performance Measure No.: 2008 NRC JPM I Examinees Name:
CUE: Comment: 1 A MG set VOLTAGE AD,IUST is in full counter-clockwise position.
Date Performed:
S-1 A, step 5.3.4.1 ,/ Pedormance step:
Facility Evaluator:
18 Rotate the MOTOR NO.
1A CIRCUIT BREAKER CONTROL switch to CLOSE. Standard:
CUE: Comment: Identifies switch, and simulate rotating to CLOSE. Component is in desired position.
CUE: S-1 A, step 5.3.4.2 Motor is at full speed. ,/ Performance Step: 19 WHEN motor is at full speed, THEN depress AND hold the FIELD FLASH pushbutton.
Standard:
Identifies FIELD FLASH pushbutton, and generator voltage indication (OUTPUT AC VOLTAGE METER). Simulate depressing and holding FIELD FLASH pushbutton.
CUE: Comment: Component is in desired condition.
S-1 A, step 5.3.4.3 WHEN Generator voltage has risen to > 234 volts AND is NOT increasing, THEN release the FIELD FLASH pushbutton.
,/ Performance step: 20 Standard:
CUE: CUE: Comment: Simulates FIELD FLASH pushbutton released.
Generator voltage has risen to 250 volts AND is steady. Component is in desired condition.
Page 7 of 13 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION S-1 A, step 5.3.4.4 Rotate the VOLTAGE ADJUST potentiometer clockwise UNTIL voltage is 260. ,/ Performance Step:
21 Standard: Rotates the VOLTAGE ADJUST potentiometer clockwise UNTIL voltage is 260. CUE: Comment: Generator voltage has risen slowly to 260 volts. S-1 A, stelp 5.3.5 Verify FIELD CURRENT is >1.2 amps AND c4.8 amps as read on the FlEiLD CURRENT METER.
Performance Step: 22 Standard:
Identifies FIELD CURRENT METER.
CUE: Comment: FIELD CURRENT is as read. S-1 A, step 5.3.6 Verify FIELD CURRENT alarm has cleared. (Alarm LED is located or the FIELD CURRENT METER)
Performance step: 23 Standard:
CUE: Comment: Identifies alarm LED on the FIELD CURRENT METER is out. Alarm LED on the FIELD CURRENT METER is out. S-1 A, step 5.3.7 Place ALARM BYPASS switch in the "ACTIVE position.
Performgnce Step: 24 Standard:
CUE: Comment: Identifies ALARM BYPASS switch and simulates placing in "ACTIVE".
Component is in desired position.
Page 8 of 13 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATlON S-1 A, step 5.3.8 Verify MCB annunciator C-21 (Rod Control MG Set Trouble) is extinguished.
Performance Step: 25 Standard:
CUE: Comment: Contacts control room on status of C-21. C-21, (Rod Control MG Set Trouble) is extinguished.
S-1 A, step 5.3.9 Rotate the synchronize switch to ON (on the MG set being started) AND allow a few seconds for the synchronizer to warm UP- ,/ Performance Step:
26 Standard:
CUE: Comment: Rotates the 1A synchronize switch to ON (AND allows a few seconds for the synchronizer to warm up. Component is in desired position.
S-1 A, step 5.3.10.1 Observe the Synchroscope (SynKRDMGAB) for indication when the two generators are in sync and trip the on-coming M/G Set Motor Breaker by rotating the circuit breaker control handle to the TRIP POSITION just after the Synchronizing Point (approximately 3 minutes after 12). 4 Performance step: 27 Standard:
Observes the Synchroscope for indication when the two generators are in sync and trips the 1A M/G Set Motor Brealker by rotating the circuit breaker control handle to the TRIP POSllnON just after the Synchronizing Point (approximately 3 minutes after 12). CUE: CUE: Comment: Component is in desired position. Synchroscope indicates the two generators are in parallel.
f'age 9 of 13 Appendix C Jab Performance Measure Form ES-C-1 PERFORMANCE INFORMATION S-1 A, step 5.3.10.2 (End Alternate Path) Should the Generator fail to parallel within 30 seconds, THEN return the synchronize switch to OFF, AND proceed with steps 5.3.1 through 5.3.10 again. N/A if generator paralleled.
Performance Step: 28 Standard:
Synchronize switch in on. CUE: Comment: Step N/Ad. Synchroscope indicates the two generators are in parallel.
S-1 A, step 5.3.1 0.3 Turn the Synchronize switch to the OFF position.
Performance Step: 29 Standard:
CUE: Comment: Synchronize switch in the OFF position.
Component is in desired Iposition.
S-1 A, step 5.3.1 1 Verify ROII DRIVE M-G SET 1A (MCB center section) red status light is lit.
Performance step: 30 Standard:
Calls Contirol Room to verify ROD DRIVE M-G SET 1A red status light is lit. CUE: Comment: From Control Room, ROD DRIVE M-G SET 1A red status light is lit. S-lA, step 5.3.12 Verify ROC) DRIVE M-G SET 16 (MCB center section) red status light is lit.
Performance step: 31 Standard: Calls Control Room to verify ROD DRIVE M-G SET 1B red status light is lit. CUE: Comment: From Control Room, ROD DRIVE M-G SET 1 B red status light is lit. F'age 10 of 13 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION S-1 A, step 5.3.13 Adjust MG1A and MG1B voltages to minimize MG CIRCULATING CURRENT (indicated on CIRCULATING CURRENT METER) with MG OUTPUT AC VOLTAGE close to 260 volts (between 250 and 270 volts) and FIELD CURRENT
~1.2 amps and <4.8 amps on both MGs. ,/ Performance Step: 32 Standard:
MG OUTPUT AC VOLTAGE close to 260 volts (between 250 and 270 volts) and FIELD CURRENT >1.2 amps and c4.8 amps on both MGs. Records Ckulating Current. CUE: Comment: CIRCULATING CURRENT is as read. S-1 A, step 5.3.1 4 Verify MCB annunciator C-21 (Rod Control MG Set Trouble) is extinguished.
Performance Step: 33 Standard:
CUE: Comment: Contacts control room on status of C-21. C-21, (Rod Control MG Set Trouble) is extinguished.
Terminating Cue: Evaluation on this JPM is complete.
STOP TIME: TIME CRITICAL STOP TIME: Page 11 of 13 Job Performance Measure Form ES-C-1 Appendix C VERIFICATION OF COMPLETION Job Performance Measure No.: Examinee's Name: Date Performed:
2008 NRC JPM I Facility Evaluator:
Number of Attempts:
Number of Attempts:
Time to Complete: Question Documentation:
Time to Complete:
Question Documentation:
Question:
Question:
Response:
 
Result: SAT UNSAT Examiner's Signature: Date:
===Response===
Page 12 of 13 Job Performance Measure Form ES-C-1 Appendix C JPM CUE SHEET Initial Conditions:
Result:                     SAT             UNSAT Examiners Signature:                                   Date:
0 You are an extra RO. 0 0 Preparations for startup of Rod Control System are under way. The "1B MG set is running. Initiating Cue: The Shift Manager directs you to startup and parallel the 1A Rod Drive MG Set per S-1A section 5.3. Simulate all activities - DO NOT MANIPULATE ANY EQUIPMENT.
Page 12 of 13
Page 130f 13
 
- Appendix C Job Performance Measure Form ES-C-1 Worksheet Facility:
Appendix C                        Job Performance Measure                     Form ES-C-1 JPM CUE SHEET Initial Conditions: 0 You are an extra RO.
Ginna Task No.: 062-029-05-04E TasWJPM Title: Align Fire Water Sysitem to Fill the JPM No.: 2008 NRC JPM J CSTs Using Condensate Transfer System WA  
0   Preparationsfor startup of Rod Control System are under way.
The " 1 B MG set is running.
Initiating Cue:     The Shift Manager directs you to startup and parallel the 1A Rod Drive MG Set per S-1A section 5.3.
Simulate all activities - DO NOT MANIPULATE ANY EQUIPMENT.
Page 130f 13
 
Appendix C                           Job Performance Measure                   Form ES-C-1 Worksheet Facility:           Ginna                                   Task No.:   062-029-05-04E TasWJPM
 
==Title:==
Align Fire Water Sysitem to Fill the   JPM No.:   2008 NRC JPM J CSTs Using Condensate Transfer System WA  


==Reference:==
==Reference:==
061 K4.01      4.1 / 4.2 Examinee:                                                NRC Examiner:
Facility Evaluator:                                      Date:
Method of testina:
Simulated Performance:      X                          Actual Performance:
Classroom            Simulator              Plant        X Applicability: RO/SRO SUBMllTED BY:                      Ted Coe                          DATE:    6/30/08 Developer REVIEWED BY:                      Art Vest                        DATE:    6/30/08 Training Technical Reviewer REVIEWED BY:                    Don Dettman                        DATE:    6/30/08 Operations Technical Reviewer APPROVED BY:                    John Blrown                        DATE:    6/30/08 Training Management Page 1 of 7


061 K4.01 4.1 / 4.2 Examinee:
Appendix C                                   Job Performance Measure                   Form ES-C-1 Worksheet Task Standard:             Line up to fill CST in accordance with ER-AFW.l section 4.3.1 and all critical tasks evahated as satisfactory.
NRC Examiner: Facility Evaluator:
Required Materials:         Proper Noise Protection, Hard Hat, Safety Glasses, Safety Shoes, Gloves. (2)Spanner wrenches and Fire Hose.
Date: Method of testina: Simulated Performance:
General  
X Actual Performance: Classroom Simulator Plant X Applicability:
RO/SRO SUBMllTED BY: Ted Coe DATE: 6/30/08 Developer REVIEWED BY: Art Vest DATE: 6/30/08 Training Technical Reviewer REVIEWED BY: Don Dettman DATE: 6/30/08 Operations Technical Reviewer APPROVED BY: John Blrown DATE: 6/30/08 Training Management Page 1 of 7 Appendix C Job Performance Measure Worksheet Form ES-C-1 Task Standard:
Line up to fill CST in accordance with ER-AFW.l section 4.3.1 and all critical tasks evahated as satisfactory.
Required Materials:
Proper Noise Protection, Hard Hat, Safety Glasses, Safety Shoes, Gloves. (2) Spanner wrenches and Fire Hose. General  


==References:==
==References:==
ER-AFW.1,: ALTERNATE WATER SUPPLY TO THE AMI PUMPS, Rev. 03001 Handouts: ER-AFW.1,: ALTERNATE WATER SUPPLY TO THE AFW PUMPS, Rev. 03001 Time Critical Task: Yes Validation Time: 11 minutes Alternate Path: NO Instructor Notes: Ensure Proper Noise Protection, Hard Hat, Safety Glasses, Safety Shoes, Gloves are worn as required.
ER-AFW.1,: ALTERNATE WATER SUPPLY TO THE A M I PUMPS, Rev. 03001 Handouts:                   ER-AFW.1,: ALTERNATE WATER SUPPLY TO THE AFW PUMPS, Rev. 03001 Time Critical Task:         Yes Validation Time:             11 minutes Alternate Path:             NO Instructor Notes:           Ensure Proper Noise Protection, Hard Hat, Safety Glasses, Safety Shoes, Gloves are worn as required.
Ensure a marked up copy of ER-AFW.l , ALTERNATE WATER SUPPLY TO THE ARN PUIMPS, Rev.03001 is ready to give to the operator during the Initiating Cue. READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues, When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
Ensure a marked up copy of ER-AFW.l , ALTERNATE WATER SUPPLY TO THE A R N PUIMPS, Rev.03001 is ready to give to the operator during the Initiating Cue.
Initial Conditions:
READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues, When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
You are an extra RO. 0 0 0 The Plant has experienced a loss of Offsite Power. CST inventory is depleted with level < 5 ft. The AFW pumps are providing S/G inventory.
Initial Conditions:             You are an extra RO.
Initiating Cue: The Shift Manager directs you to align the Fire Water System to fill the CSTs using the Condensate Transfer System in accordance with ER- AFW.l section 4.3.1. Simulate all activities - DO NOT MANIPULATE ANY EQUIPMENT.
0   The Plant has experienced a loss of Offsite Power.
This is a time critical JPM. CUE: Hand the Operator a marked up copy of ER-AFW.l, Rev. 03001. '>age 2 of 7 Appendix C Jc b Performance Measure PERFORMANCE INFORMATION Form ES-C-1 START TIME: d = CRITICAL STEP ER-AFW:I , step 4.3.1.1 Place Howell Level Controller LC-107 in manual at 50%. Performance Step:
0    CST inventory is depleted with level < 5 ft.
1 Standard:
0    The AFW pumps are providing S/G inventory.
CUE: Comment: Simulates requesting Control Room place Hotwell Level Controller in manual and 50% output. Acknowledge request and inform the examinee that the Hotwell Level controller is in manual at 50% output. ER-AFW.ll, step 4.3.1.2 ,/ Performance step: 2 Close or verify closed the following valves: CNDST XFER PUMP DISCH ISOL TO HOSE TAPS, valve 4049C 0 CNDST XFER PUMP DISCH SAMPLE, valve 4049A 0 CNDST XFER PUMP DISCH TO MIX BED POLISHER DIS, valve 4050 0 CNDST XFER PUMP DISCH TO CST, valve 9509C 0 CNDST XFER PUMP SUCTION ISOL FROM HOWELL, valve 4046 (in east condenser pit) CNDST XFER PUMP SUCTION FROM A&B CST, valve 4047 0 OUTSIDE CST FILL ISOL, valve 9509D Standard:
Initiating Cue:             The Shift Manager directs you to align the Fire Water System to fill the CSTs using the Condensate Transfer System in accordance with ER-AFW.l section 4.3.1.
Finds, iderltifies and closes or verifies closed the following valves: 1. CNDST XFER PUMP DISCH ISOL TO HOSE TAPS, valve 4049C 2. CNiDST XFER PUMP DISCH SAMPLE, valve 4049A 3. CNIXT XFER PUMP DISCH TO MIX BED POLISHER DE;, valve 4050
Simulate all activities - DO NOT MANIPULATE ANY EQUIPMENT.
This is a time critical JPM.
CUE: Hand the Operator a marked up copy of ER-AFW.l, Rev. 03001.
                                                  '>age 2 of 7
 
Appendix C                           Jc b Performance Measure                       Form ES-C-1 PERFORMANCE INFORMATION START TIME:
d = CRITICAL STEP ER-AFW:I ,step 4.3.1.1 Performance Step: 1      Place Howell Level Controller LC-107 in manual at 50%.
Standard:                 Simulates requesting Control Room place Hotwell Level Controller in manual and 50% output.
CUE:    Acknowledge request and inform the examinee that the Hotwell Level controller is in manual at 50% output.
Comment:
ER-AFW.ll, step 4.3.1.2
/, Performance step: 2       Close or verify closed the following valves:
CNDST XFER PUMP DISCH ISOL TO HOSE TAPS, valve 4049C 0   CNDST XFER PUMP DISCH SAMPLE, valve 4049A 0   CNDST XFER PUMP DISCH TO MIX BED POLISHER DIS, valve 4050 0   CNDST XFER PUMP DISCH TO CST, valve 9509C 0   CNDST XFER PUMP SUCTION ISOL FROM HOWELL, valve 4046 (in east condenser pit)
CNDST XFER PUMP SUCTION FROM A&B CST, valve 4047 0   OUTSIDE CST FILL ISOL, valve 9509D Standard:                 Finds, iderltifies and closes or verifies closed the following valves:
: 1. CNDST XFER PUMP DISCH ISOL TO HOSE TAPS, valve 4049C
: 2. CNiDST XFER PUMP DISCH SAMPLE, valve 4049A
: 3. CNIXT XFER PUMP DISCH TO MIX BED POLISHER DE;, valve 4050
: 4. CNIXT XFER PUMP DISCH TO CST, valve 9509C
: 4. CNIXT XFER PUMP DISCH TO CST, valve 9509C
: 5. CNBST XFER PUMP SUCTION ISOL FROM HOWELL, valve 4046 (in east condenser pit) 6. CNIXT XFER PUMP SUCTION FROM A&B CST, valve 4047 7. OUTSIDE CST FILL ISOL, valve 95090 Component is in desired position. (for each valve operated)
: 5. CNBST XFER PUMP SUCTION ISOL FROM HOWELL, valve 4046 (in east condenser pit)
CUE: Comment: Page 3 of 7 Appendix C Jl3b Performance Measure Form ES-C-1 PERFORMANCE INFORMATION ER-AFW,,l, step 4.3.1.3 Obtain tho spanner wrenches (on handrail by Cond Transfer Pump). Performance Step: 3 Standard:
: 6. CNIXT XFER PUMP SUCTION FROM A&B CST, valve 4047
Locates spanner wrenches.
: 7. OUTSIDE CST FILL ISOL, valve 95090 CUE:    Component is in desired position. (for each valve operated)
CUE: You have two spanner wrenches.
Comment:
Comment: ER-AFW.l, step 4.3.1.4 Isolate/rernove and cap all temporary hoses from the connections at CNDST XFER PUMP DISCH ISOL TO HOSE TAPS, valve 4049C. Performance step: 4 Standard:
Page 3 of 7
CUE: Comment: Finds and simulates removing and capping hoses connected at valve 404!E. All hoses are disconnected and capped. ER-AFW.l, step 4.3.1.5 Run the hose from fire water hose reel #2 (located by Battery Room door) AND connect at CNDST XFER PUMP DISCH ISOL TO HOSE TAPS, valve 4049C. ,,/ Performance Step: 5 Standard:
 
CUE: Comment: Simulates running hose from hose reel #2 to valve 4049C. The hose is connected between hose reel #2 and valve 4049C. ER-AFW.1, step 4.3.1.6 NOTE Performance step: 6 NOTE: The! Diesel Fire Pump should auto start while performing the following.
Appendix C                         Jl3b Performance Measure                   Form ES-C-1 PERFORMANCE INFORMATION ER-AFW,,l,step 4.3.1.3 Performance Step: 3      Obtain tho spanner wrenches (on handrail by Cond Transfer Pump).
Standard:
Standard:               Locates spanner wrenches.
CUE: Acknowledge report, if made. Comment: Placekeeps and reads note. May inform control room. f'age 4 of 7 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION ER-AFW.l, step 4.3.1.6 4 Performance Step: 7 Slowly open the following valves: CNDST XFER PUMP RECIRC, valve 4048 CFJDST XFER PUMP DISCH ISOL TO HOSE TAPS, valve 40496 0 TLlRBlNE BLDG HOSE REEL  
CUE:   You have two spanner wrenches.
#2 ISOL, valve 5178 Standard:
Comment:
Finds, identifies and slowly opens the following valves: 1. CNDST XFER PUMP RECIRC, valve 4048
ER-AFW.l, step 4.3.1.4 Performance step: 4      Isolate/rernove and cap all temporary hoses from the connections at CNDST XFER PUMP DISCH ISOL TO HOSE TAPS, valve 4049C.
: 2. CNDST XFER PUMP DlSCH ISOL TO HOSE TAPS, valve 4049C 3. TURBINE BLDG HOSE REEL #2 ISOL, valve 5178 CUE: Comment: Component is in desired position. (for each valve operated)
Standard:               Finds and simulates removing and capping hoses connected at valve 404!E.
Record TIME CRITICAL STOP TIME, must be less than 12 minutes firom start time. ER-AFW.1, step 4.3.1.7 Performance Step: 8 Fill CSTS 21s required.
CUE:    All hoses are disconnected and capped.
Standard:
Comment:
Monitors fillling CST. CUE: No further action requiredl.
ER-AFW.l, step 4.3.1.5
Comment: Terminating Cue: Evaluatiori on this JPM is complete.
/,, Performance Step: 5      Run the hose from fire water hose reel #2 (located by Battery Room door) AND connect at CNDST XFER PUMP DISCH ISOL TO HOSE TAPS, valve 4049C.
STOP TIME: TIME CRITICAL STOP TIME:
Standard:               Simulates running hose from hose reel #2to valve 4049C.
Page 5 of 7 Appendix C Job Performance Measure Form ES-C-1 VERIF:ICATION OF COMPLETION Job Performance Measure No.: 2008 IVRC JPM J Examinee's Name: Date Performed:
CUE:    The hose is connected between hose reel #2 and valve 4049C.
Comment:
ER-AFW.1, step 4.3.1.6 NOTE Performance step: 6     NOTE: The! Diesel Fire Pump should auto start while performing the following.
Standard:               Placekeeps and reads note. May inform control room.
CUE:     Acknowledge report, if made.
Comment:
fage 4 of 7
 
Appendix C                         Job Performance Measure                     Form ES-C-1 PERFORMANCE INFORMATION ER-AFW.l, step 4.3.1.6 4 Performance Step: 7     Slowly open the following valves:
CNDST XFER PUMP RECIRC, valve 4048 CFJDST XFER PUMP DISCH ISOL TO HOSE TAPS, valve 40496 0 TLlRBlNE BLDG HOSE REEL #2 ISOL, valve 5178 Standard:               Finds, identifies and slowly opens the following valves:
: 1. CNDST XFER PUMP RECIRC, valve 4048
: 2. CNDST XFER PUMP DlSCH ISOL TO HOSE TAPS, valve 4049C
: 3. TURBINE BLDG HOSE REEL #2 ISOL, valve 5178 CUE:     Component is in desired position. (for each valve operated)
Comment:                Record TIME CRITICAL STOP TIME, must be less than 12 minutes firom start time.
ER-AFW.1, step 4.3.1.7 Performance Step: 8     Fill CSTS 21s required.
Standard:               Monitors fillling CST.
CUE:     No further action requiredl.
Comment:
Terminating Cue:           Evaluatiori on this JPM is complete.
STOP TIME:                                   TIME CRITICAL STOP TIME:
Page 5 of 7
 
Appendix C                       Job Performance Measure       Form ES-C-1 VERIF:ICATION OF COMPLETION Job Performance Measure No.: 2008 IVRC JPM J Examinees Name:
Date Performed:
Facility Evaluator:
Facility Evaluator:
Number of Attempts:
Number of Attempts:
Line 761: Line 1,454:
Question Documentation:
Question Documentation:
Question:
Question:
Response:
 
Result: UNSAT -- SAT Examiner's Signature:
===Response===
Date: Page 6 of 7 Appendix C Job Performance Measure JPM CUE SHEET Form ES-C-1 Initial Conditions:
Result:                     SAT  --         UNSAT Examiners Signature:                                   Date:
0 You are an extra RO. 0 0 0 The Plant has experienced a loss of Offsite Power CST inventoiy is depleted with level < 5 ft. The AFW pumps are providing S/G inventory.
Page 6 of 7
Initiating Cue: The Shift Manager directs you to align the Fire Water System to fill the CSTs using the Condensate Transfer System in accordance with ER- Am. 1 section 4.,3.1. Simulate all activities - DO NOT MANIPULATE ANY EQUIPMENT.
 
This is a time critical JPM. Page 7 of 7 Appendix C Jc b Performance Measure Form ES-C-1 Worksheet Facility:
Appendix C                         Job Performance Measure                   Form ES-C-1 JPM CUE SHEET Initial Conditions: 0   You are an extra RO.
TasWJPM Title: WA  
0   The Plant has experienced a loss of Offsite Power CST inventoiy is depleted with level < 5 ft.
The AFW pumps are providing S/G inventory.
Initiating Cue:     The Shift Manager directs you to align the Fire Water System to fill the CSTs using the Condensate Transfer System in accordance with ER-A m . 1 section 4.,3.1.
Simulate all activities - DO NOT MANIPULATE ANY EQUIPMENT.
This is a time critical JPM.
Page 7 of 7
 
Appendix C                             Jc b Performance Measure               Form ES-C-1 Worksheet Facility:           Ginna                                Task No.:  062-030-05-04A TasWJPM
 
==Title:==
Trip of Failed AC Emergency UV        JPM No.:    2008 NRC JPM K Relay WA  


==Reference:==
==Reference:==
APE 077 AA1.05        3.9/4.0 Examinee:                                              NRC Examiner:
Facility Evaluator:                                    Date:
Method of testina:
Simulated Performance:        X                        Actual Performance:
Classroom            Simulator          Plant        X Applicability: RO/SRO SUBMITTED BY:                        Ted Coe                      DATE:    6/30/08 Developer REVIEWED BY:                        Art Vest                      DATE:    6/30/08 Training Technical Reviewer REVIEWED BY:                      Don Dettman                    DATE:    6/30/08 Operations Technical Reviewer APPROVED BY:                    John Brown                      DATE:    6/30/08 Training Management Page 1 of 6


Examinee:
Appendix C                                   Job Performance Measure                   Form ES-C-1 Worksheet Task Standard:             Perform a manual trip of a relay for undervoltage protection on Bus 14 and all critical tasks evaluated as satisfactory.
Facility Evaluator:
Required Materials:         Proper Noise Protection, Hard Hat, Safety Glasses, Safety Shoes, Gloves.
Method of testina: Ginna Task No.:
Undervoltage cabinet key #25 (the use of this key will be simulated).
062-030-05-04A Trip of Failed AC Emergency UV Relay JPM No.: 2008 NRC JPM K APE 077 AA1.05 3.9/4.0 NRC Examiner:
Date: Simulated Performance:
X Actual Performance: Classroom Simulator Plant X Applicability:
RO/SRO SUBMITTED BY: Ted Coe DATE: 6/30/08 Developer REVIEWED BY: Art Vest DATE: 6/30/08 Training Technical Reviewer REVIEWED BY: Don Dettman DATE: 6/30/08 Operations Technical Reviewer APPROVED BY: John Brown DATE: 6/30/08 Training Management Page 1 of 6 Appendix C Job Performance Measure Form ES-C-1 Worksheet Task Standard:
Required Materials:
General  
General  


==References:==
==References:==
ER-UV.l, TRIP OF FAILED AC EMERGENCY UV RELAY, Rev. 5 Handouts:                  ER-UV.1, TRIP OF FAILED AC EMERGENCY UV RELAY, Rev. 5 Time Critical Task:        NO Validation Time:            10 minutes Alternate Path:            NO Instructor Notes:          Ensure Proper Noise Protection, Hard Hat, Safety Glasses, Safety Shoes, Gloves are worn as required.
Ensure a marked up copy of ER-UV.l, TRIP OF FAILED AC EMERGENCY UV RELAY, Rev. 5 is ready to give to the operator during the Initiating Cue and undervoltage cabinet key #25.
READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
Initial Conditions:              0  You are an extra RO.
0  The control room has received L-14, Bus 14 Undervoltage Safeguards annunciator.
0  Procedure ER-UV.1, TRIP OF FAILED AC EMERGENCY UV RELAY is being performed and the control room staff is at step 4.2.2.
Initiating Cue:            The CRS directs you to perform a manual trip of Loss of Voltage 27 D/B relay for Bus 14 por Attachment BUS 14, PART B of ER-UV.l.
Simulate all activities - DO NOT MANIPULATE ANY EQUIPMENT, Bus 14, Attachment BUS 14, PART A of ER-UV.l has NOT been performed.
CUE: Hand the Operator a marked up copy of ER-UV.l, TRIP OF FAILED AC EMERGENCY UV RELAY, Rev. 5 and undervoltage cabinet key #25.
Page 2 of 6


Handouts:
Appendix C                           Job Performance Measure                     Form ES-C-1 PERFORMANCE INFORMATION START TIME:
Time Critical Task: Validation Time: Alternate Path: Instructor Notes: Perform a manual trip of a relay for undervoltage protection on Bus 14 and all critical tasks evaluated as satisfactory. Proper Noise Protection, Hard Hat, Safety Glasses, Safety Shoes, Gloves. Undervoltage cabinet key
4 = CRITICAL STEP ER-UV.l, Att. Bus 14, part 8, step 6.1 Performance Step: 1      Verify Part A has NOT been performed.
#25 (the use of this key will be simulated).
Standard:                 Verifies with Part A has not been performed, given in initiating cue, may call control room or may check Part A for Bus 14.
ER-UV.l, TRIP OF FAILED AC EMERGENCY UV RELAY, Rev.
CUE:    If requested, report as CFIS Part A for Bus 14, has not been performed.
5 ER-UV.1, TRIP OF FAILED AC EMERGENCY UV RELAY, Rev. 5 NO 10 minutes NO Ensure Proper Noise Protection, Hard Hat, Safety Glasses, Safety Shoes, Gloves are worn as required. Ensure a marked up copy of ER-UV.l, TRIP OF FAILED AC EMERGENCY UV RELAY, Rev. 5 is ready to give to the operator during the Initiating Cue and undervoltage cabinet key #25. READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
Initial Conditions:
0 You are an extra RO. 0 The control room has received L-14, "Bus 14 Undervoltage Safeguards" annunciator.
0 Procedure ER-UV.1, TRIP OF FAILED AC EMERGENCY UV RELAY is being performed and the control room staff is at step 4.2.2. Initiating Cue: The CRS directs you to perform a manual trip of Loss of Voltage 27 D/B relay for Bus 14 por Attachment BUS 14, PART B of ER-UV.l. Simulate all activities - DO NOT MANIPULATE ANY EQUIPMENT, Bus 14, Attachment BUS 14, PART A of ER-UV.l has NOT been performed.
CUE: Hand the Operator a marked up copy of ER-UV.l, TRIP OF FAILED AC EMERGENCY UV RELAY, Rev.
5 and undervoltage cabinet key #25. Page 2 of 6 Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION START TIME: 4 = CRITICAL STEP ER-UV.l, Att. Bus 14, part 8, step 6.1 Verify Part A has NOT been performed.
Performance Step: 1 Standard:
CUE: Comment: Verifies with Part A has not been performed, given in initiating cue, may call control room or may check Part A for Bus 14. If requested, report as CFIS Part A for Bus 14, has not been performed.
If local indications are checked: Component is in as found position.
If local indications are checked: Component is in as found position.
ER-UV.l , Att. Bus 14, part 6, step 6.2 Auxiliary Flelay Rack (bottom left hand corner) to the TEST position. (Key cannot be removed w hen in TEST position.)
Comment:
4 Performance Step: 2 Place the
ER-UV.l , Att. Bus 14, part 6, step 6.2 4  Performance Step: 2      Place the TEST ENABLE key switch (S20)on the BUS14 Auxiliary Flelay Rack (bottom left hand corner) to the TEST position. (Key cannot be removed w hen in TEST position.)
'TEST ENABLE key switch (S20) on the BUS 14 Standard:
Standard:                 Locates kay switch and simulates inserting key and rotating key to TEST position.
CUE: Comment: Locates kay switch and simulates inserting key and rotating key to TEST position.
CUE:    Component is in desired position.
Component is in desired position.
Comment:
Dage 3 of 6 Appendix C Job Performance Measure Form ES-C-1 PERF'ORMANCE INFORMATION ER-UV.l, Att. Bus 14, part B, step 8.3 Place each individual Auxiliary Relay toggle switch to the TRIP position and verify that each Yellow UV light energizes or remains energized. (Located on the Auxiliary Relay Rack)  
Dage3 of 6
,/ Performance Step: 3 0 0 0 0 0 Relay BX1/14 Toggle sw itch to TRIP Yellow UV Light LIT MCB Annunciator L-14 ENERGIZED Relay BX2/14 Toggle switch to TRIP Yellow UV Light LIT Relay BX3/14 Toggle switch to TRIP Yellow UV Light LIT Relay BX4/14 Toggle switch to TRIP Yellow UV Light LIT Remlay BX5/14 Toggle switch to TRIP Yellow UV Light LIT Relay BX6/14 Toggle switch to TRIP Yellow UV Light LIT Standard:
 
Locates each toggle switch listed and simulates toggling switch to TRIP. Verifies UV light lit for each toggle switch operated.
Appendix C                         Job Performance Measure                       Form ES-C-1 PERFORMANCE INFORMATION ER-UV.l, Att. Bus 14, part B, step 8.3
0 Relay BX1/14 Toggle sw itch in TRIP Yellow UV Light LIT MCB Annunciator L-14 ENERGIZED 0 Relay BX2/14 Toggle switch in TRIP Yellow UV Light LIT 0 Relay BX3/14 Toggle switch in TRIP Yellow UV Light LIT Relay BX4/14 Toggle switch in TRIP Yellow UV Light LIT 0 Relay BX5/14 Toggle switch in TRIP Yellow UV Light LIT Relay BX6/14 Toggle switch in TRIP Yellow UV Light LIT CUE: Component is in desired position.  
/,    Performance Step: 3    Place each individual Auxiliary Relay toggle switch to the TRIP position and verify that each Yellow UV light energizes or remains energized. (Located on the Auxiliary Relay Rack) 0   Relay BX1/14 Toggle sw itch to TRIP Yellow UV Light LIT MCB Annunciator L-14 ENERGIZED Relay BX2/14 Toggle switch to TRIP Yellow UV Light LIT Relay BX3/14 Toggle switch to TRIP Yellow UV Light LIT Relay BX4/14 Toggle switch to TRIP Yellow UV Light LIT Remlay BX5/14 Toggle switch to TRIP Yellow UV Light LIT Relay BX6/14 Toggle switch to TRIP Yellow UV Light LIT Standard:                 Locates each toggle switch listed and simulates toggling switch to TRIP. Verifies UV light lit for each toggle switch operated.
/ Light is lit. / MCB Ann. Is energized.
0   Relay BX1/14 Toggle sw itch in TRIP Yellow UV Light LIT MCB Annunciator L-14 ENERGIZED 0   Relay BX2/14 Toggle switch in TRIP Yellow UV Light LIT 0   Relay BX3/14 Toggle switch in TRIP Yellow UV Light LIT Relay BX4/14 Toggle switch in TRIP Yellow UV Light LIT 0   Relay BX5/14 Toggle switch in TRIP Yellow UV Light LIT Relay BX6/14 Toggle switch in TRIP Yellow UV Light LIT CUE:     Component is in desired position. / Light is lit. / MCB Ann. Is energized.
Comment: ER-UV.l, Att. Bus 14, part B, step 8.4 Performance Step: 4 Return to :;tep 4.2.3. Standard:
Comment:
CUE: Acknowledge report.
ER-UV.l, Att. Bus 14, part B, step 8.4 Performance Step: 4     Return to :;tep 4.2.3.
Comment: Contacts the control room to continue on at step 4.2.3. Terminating Cue: Evaluation on this JPM is complete.
Standard:               Contacts the control room to continue on at step 4.2.3.
STOP TIME: TIME CRITICAL STOP TIME: Page 4 of 6 Appendix C Jot) Performance Measure Form ES-C-1 VERIFICATION OF COMPLETION Job Performance Measure No.: 2008 NIRC JPM K Examinee's Name: Date Performed:
CUE:    Acknowledge report.
Comment:
Terminating Cue:           Evaluation on this JPM is complete.
STOP TIME:                                 TIME CRITICAL STOP TIME:
Page 4 of 6
 
Appendix C                       Jot) Performance Measure       Form ES-C-1 VERIFICATION OF COMPLETION Job Performance Measure No.: 2008 NIRC JPM K Examinees Name:
Date Performed:
Facility Evaluator:
Facility Evaluator:
Number of Attempts:
Number of Attempts:
Line 815: Line 1,527:
Question Documentation:
Question Documentation:
Question:
Question:
Response:
 
Result: SAT UNSAT Examiner's Signature:
===Response===
Date: Page 5 of 6 Appendix C Job Performance Measure JPM CUE SHEET Form ES-C-1 Initial Conditions:
Result:                     SAT               UNSAT Examiners Signature:                                   Date:
You are an extra RO. The contr'3l room has received L-14, "Bus 14 Undervoltage Safeguards" annunciator.
Page 5 of 6
0 Procedurc ER-UV.1, TRIP OF FAILED AC EMERGENCY UV RELAY is being performed and the control room staff is at step 4.2.2. Initiating Cue: The CRS directs you to perform a manual trip of Loss of Voltage 27 D/B relay for Bus 14 per Attachment BUS 14, PART B of ER-UV. 1. Simulate all activities - DO NOT MANIPULATE ANY EQUIPMENT.
 
Bus 14, Attachment BUS 14, PART A of ER-UV. 1 has UT been performed.
Appendix C                         Job Performance Measure                   Form ES-C-1 JPM CUE SHEET Initial Conditions:         You are an extra RO.
The contr3l room has received L-14, Bus 14 Undervoltage Safeguards annunciator.
0   Procedurc ER-UV.1, TRIP OF FAILED AC EMERGENCY UV RELAY is being performed and the control room staff is at step 4.2.2.
Initiating Cue:     The CRS directs you to perform a manual trip of Loss of Voltage 27 D/B relay for Bus 14 per Attachment BUS 14, PART B of ER-UV.1.
Simulate all activities - DO NOT MANIPULATE ANY EQUIPMENT.
Bus 14, Attachment BUS 14, PART A of ER-UV.1 has U T been performed.
Page 6 of 6}}
Page 6 of 6}}

Latest revision as of 20:22, 12 March 2020

R. E. Ginna Draft - Section B Operating Exam (Folder 2)
ML082950425
Person / Time
Site: Ginna Constellation icon.png
Issue date: 09/01/2008
From:
Ginna
To: Todd Fish
Operations Branch I
Hansell S
Shared Package
ML080030004 List:
References
TAC U01687
Download: ML082950425 (106)


Text

Appendix C Job Performance Measure Form ES-C-1 Worksheet FaciIity: Ginna Task No.: 004-037-01-01 TasWJPM

Title:

Alternate Dilution of the RCS (WB JPM No.: 2008 NRC JPM A occurs during dilution)

WA

Reference:

004 A2.16 3.2 / 3.6 Examinee: NRC Examiner:

Facility Evaluator: Date:

Method of testina:

Simulated Performance: Actual Performance: X Classroom Simulator X Plant Applicability: RO/SRO SUBMITTED BY: Ted Coe DATE: 6/30/08 Developer REVIEWED BY: Art Vest DATE: 6/30/08 Training Techinical Reviewer REVIEWED BY: Don Dettman DATE: 6/30/08 Operations Teclinical Reviewer APPROVED BY: John Elrown DATE: 6/30/08 Training Management Page 1 of 9

Appendix C Jot) Performance Measure Form ES-C-1 Worksheet Task Standard: Alternate dilution is secured and all critical tasks evaluated as satisfactory.

Required Materials: None General

References:

S-3.1, Boron Concentration Control, Rev. 02900 S-12.4, RCS Leakage Surveillance Record Instructions, Rev.54 Handouts: S-3.1, Boron Concentration Control, Rev. 02900 S-12.4, RCS Leakage Surveillance Record Instructions, Rev.54, Attachment RCS iLeakage Surveillance Record Time Critical Task: NO Validation Time: 15 minutes Alternate Path: Yes Instructor Notes: Have the Reactivity Binder cleaned and a copy of S-12.4, Attachment RCS Leakage Surveillance Record available for examinee.

READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task succlsssfully, the objective for this Job Performance Measure will be satisfied.

Initial Conditions: You are the HCO.

0 I will be the CRS of the CO if you need one.

0 The plant is at 98.5% power in a normal 50/50at power lineup.

0 Attachment 1, Makeup Determinations of S-3.1, Boron Concentration Control has been completed.

Initiating Cue: Perform an alternate dilution of 100 gallons of water at 20 gpm to maintain Tave at Tref.

Page 2 of 9

Appendix C Job Performance Measure Form ES-C-1 Worksheet SIMULATOR SETUP For the 2008 ILT NRC Exam load IIC # 171 or Any 100% IC (IC-19).

The plant in a normal 100°/o powor lineup.

In a normal 50/50electric lineup.

RMW PUMP 1B in Pull-Stop.

Ensure Tave is slightly below Tref.

Insert NIS07A, PR Channel Failure CH: N-41 failed low on Manual Trigger 1.

Control Rods in auto.

Set RMW to BA Blender flow control valve, HCV-111 controller to 40 gpm.

Page 3 of 9

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION START TIME:

d = CRITICAL STEP S-3.1, Att. 4, step 1.O Performance Step: 1 ENSURE Attachment 1, Makeup Determinations, is complete.

Standard: Given in the initial cue.

Comment:

S-3.1, Att. 4, step 2.0 and 2.1 performance step: 2 2.0 The board operator SHALL inform the CRS (SM in the CRSS absence) of the intent to change core reactivity.

2.1 The C:RS (SM in the CRSs absence) SHALL acknowledge the reactivity manipulation and provide input and oversight.

Standard: Informs CRS of 100 gallons of water addition. (or something to that effect)

CUE: Acknowledge report.

Comment:

S-3.1 ,Att,,4, step 3.0 4 Performance Step: 3 PLACE RIUW MODE SELECTOR control switch to ALT DIL position.

Standard: RMW MODE SELECTOR in ALT OIL.

Comment:

S-3.1, Att. 4, step 4.0 Performance Step: 4 SET RMW TO BA BLENDER FLOW CONTROL VLV, HCV 111, controller to the desired flow rate.

Standard: RMW TO IBA BLENDER FLOW CONTROL VLV, HCV 111, controller, set to 20 gpm.

Comment:

Page 4 of 9

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE I NFORMATION S-3.1, AH. 4, step 5.0 4 Performance Step: 5 SET the RMW COUNTER, YIC-111, to the quantity determined in Attachment 1, Step 2.1.

Standard: RMW COUNTER, YIC-111 set to 10 0 gallons.

Comment:

S-3.1, Att. 4, step 6.0 4 Performance Step: 6 PLACE RMW CONTROL control switch to START position.

Standard: RMW COlNTROL switch to START and released.

Red light on, Green light off.

Comment:

S-3.1, A#,, 4, step 7.0 Performance Step: 7 VERIFY the following:

0 Rh4W PUMP 1A OR 1B STARTS.

0 REiACTOR MAKEUP TO VCT, AOV 1lOC, opens.

0 RhllW TO BA BLENDER FLOW CONTROL VLV, HCV 111, valve throttles open to the preset flow position.

RElACTOR MAKEUP TO CHG PUMP, AOV-1 lOB, opens.

Standard: 0 RMW PUMP 1A STARTS. Red light on, Green light off.

0 AOV 11OC, opens. Red light on, Green light off.

0 HC:V 111, valve throttles open to the preset flow position.

ACIV-1106, opens. Red light on, Green light off.

SIM OPERATOR: As soon as the student has completed verifying proper lineup insert Manual Triigger 1.

Comment:

Page 5 of 9

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION (Start Altlernate Path)

/, Performance Step: 8 PLACE RMW CONTROL switch to STOP position.

Standard: The examinee determines a Rod Block exists and per the note prior to step 6.0 immediately secures the dilution operation.

RCAW CONTROL switch in STOP.

Red light off, Green light on.

CUE: Acknowledge reports.

CUE: HCO continue with S-3.1 Attachment 4, the CO will address the other issues.

Comment:

S-3.1, Att. 4, step 8.0 (End Alternate Path)

/, Performance step: g WHEN dilution is complete, THEN PERFORM the following:

8.1 F'LACE RMW MODE SELECTOR control switch to AUTO position.

8.2 P U C E RMW CONTROL switch to START position, and verify RMW control red light illuminated.

8.3 SET RMW TO BA BLENDER FLOW CONTROL VLV, tiCV 1 11, controller to the normal flow setpoint of 40 GPM.

Standard: 8.1 RMW MODE SELECTOR control switch to AUTO position.

8.2 RMW CONTROL switch in START position, Red light OII, Green light off.

8.3 RMW TO BA BLENDER FLOW CONTROL VLV, HCV 111, controller at 40 GPM.

Comment:

S-3.1, Att. 4, step 9.0 Performance Step: 10 RECORD the amount of reactor makeup water added on S-12.4, RCS Leakage Surveillance Record Instructions, Attachment RCS Leakage Slurveillance Record.

Standard: Amount added in gallons of water recorded on S-12.4, RCS Leakage Surveillance Record Instructions, Attachment RCS Leakage Surveillance Record.

Comment:

Page 6 of 9

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION S-3.1, Atto,4, step 10.0 Performance Step: 11 The board operator SHALL inform the CRS (SM in the CRSS absence) the reactivity manipulation is complete.

Standard: CRS notified that reactivity manipulation is complete.

CUE: Acknowledge report.

Comment:

Terminating Cue: Evaluation on this JPM is complete.

STOP TIME: TIME CRITICAL STOP TIME:

Page 7 of 9

Appendix C Job Performance Measure Form ES-C-1

~

VERI FXATION OF COMPLETION Job Performance Measure No.: 2008 NRC JPM A Examinees Name:

Date Performed:

Facility Evaluator:

Number of Attempts:

Time to Complete:

Question Documentation:

Question:

Response

Result: SAT -- UNSAT Examiners Signature: Date:

Page 8 of 9

Appendix C Job Performance Measure Form ES-C-1 JPM CUE SHEET Initial Conditions: You are the HCO.

I will be the CRS of the CO if you need one.

The plant is at 98.5% power in a normal 50/50 at power lineup.

Attachment 1, Makeup Determinations of S-3.1, Boron Concentration Control has been completed.

Initiating Cue: Perform an alternate dilution of 100 gallons of water at 20 gpm to maintain Tave at Tref.

Page 9 of 9

Appendix C Job Performance Measure Form ES-C-1 Worksheet Facility: Ginna Task No.: 006-018-05-01A TasWJPM

Title:

Transfer ECCS to Cold Leg JPM No.: 2008 NRC JPM B Recirculation (Alt. Path)

WA

Reference:

EPE 01 1 EA1.11 4.2 / 4.2 Examinee: NRC Examiner:

Facility Evaluator: Date:

Method of testina:

Simulated Performance: Actual Petformance: X Classroom Simulator X Plant Applicability: RO/SRO SUBMllTED BY: Ted Coe DATE: 6/30/08 Devleloper REVIEWED BY: Art Vest DATE: 6130108 Training Technical Reviewer REVIEWED BY: Don Dettman DATE: 6/30/08 Operations Technical Reviewer APPROVED BY: John Elrown DATE: 6/30/08 Training Management Page 1 Of 14

Appendix C Job Performance Measure Form ES-C-1 Worksheet Task Standard: One RHR pump running, taking suction from the Containment Wsump and all critical tasks evaluated as satisfactory.

Required Materials: DC power panel key.

General

References:

ES-1.3, TRANSFER TO COLD LEG RECIRCULATION, Rev. 04200 Handouts: ES-1.3, TRANSFER TO COLD LEG RECIRCULATION, Rev. 04200 Time Critical Task: NO Validation Time: 15 minutes Alternate Path: YES Instructor Notes: None READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.

Initial Conditions: You are the HCO.

0 Reactor trip with SI occurred.

0 The has CRS initiated loss of coolant actions 0 RWST level is at 28% and trending down slowly.

0 The Control Room crew is currently at Step 22 of E-1.

Initiating Cue: The CRS directs you to transfer to Cold Leg Recirculation per ES-1.3, Transfer to Cold Leg Recirculation.

Page 2of 14

Appendix C Job Performance Measure Form ES-C-1 Worksheet SllllULATOR SETUP For the 2008 ILT NRC Exam load I/C: # 172 and Freeze the simulator until the operator is ready to start then go to run.

or e Any at power IC.

a Max break LOCA.

a Insert MALF RCS03B.

a Ensure (4) SW pumps running.

a Complete E-1 up to Step 19 with RWST Level > 28% (approx. 29%).

e Ensure both CS Pumps are running.

a Ensure A CCW Pump is running.

a Ensure B CCW Pump is secured.

a Insert trip CLG02B for B CCW Pump.

a Ensure MOV-738A and 7388 are closed.

e Freeze simulator until operator re'sdy to start then go to run.

Page 3 of 14

~ ~ ~~~ ~ ~~~ ~

Appendix C Job Performance Measure Form ES-C-1 PERF:ORMANCE INFORMATI0N START TIME:

.I= CRITICAL STEP ES-1.3, step 1 Performance Step: 1 Verify RWST level - GREATER THAN 15%

Standard: Monitors RWST Level. IF sump recirculation NOT in progress, THEN pull-stop all pumps taking suction from RWST, EXCEPT one SI pu~npAND go to ECA-1.1, LOSS OF EMERGENCY COOLANT RECIRCULATION, Step 1.

Comment:

ES-1.3, slep 2 Performance Step: 2 Verify CNIVlT Sump B Level - AT LEAST 113 INCHES Standard: Locates and identifies CNMT Sump B Level is at least 113 INCHES.

(2)113 inches Red indicator lights lit on CNMT Sump Level Indicator.

Comment:

Standard: Depresses SI reset P/B.

Comment:

ES-1.3, step 4.a Performance Step: 4 Check IF Llnnecessary Pumps Can Be Stopped:

a. Three SI pumps - RUNNING Standard: Locates and identifies A, B and C SI pumps running.

Red lights on and Green lights off.

Comment:

IPage 4 of 14

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION ES-1.3, step 4.b

/, Performance Step: 5 Stop SI plJmp C and place both switches in PULL STOP Standard: Locates and identifies Bus 14 SI pump C and places switch in PULL STOP.

Locates and identifies Bus 16 SI pump C and places switch in PULL STOP.

Red lights; off and Green lights off.

Comment:

ES-1.3, step 4.c 4 Performance Step: 6 Stop both RHR pumps and place in PULL STOP Standard: Locates and identifies A RHR pump and places switch in PULL STOP.

Locates alrld identifies B RHR pump and places switch in PULL STOP.

Red lights off and Green lights off.

Comment:

ES-1.3,step 4.d Performance Step: 7 Both CNMT spray pumps - RUNNING Standard: Locates arid identifies A and B CNMT spray pumps running.

Red lights on and Green lights off.

Comment:

Page 5 of 14

Appendix C Jab Performance Measure Form ES-C-1 PERFORMANCE NFORMATION Standard: Locates and identifies A CS pump switch and places in PULL STOP.

or Locates and identifies B CS pump switch and places in PULL STOP.

Red light off and Green light off for secured pump.

Comment:

ES-1.3, sl:ep4.f Performance Step: 9 Check ChlMT pressure - LESS THAN 28 PSlG Standard: Locates alnd identifies on PI-944, 945,947 or 949 CNMT pressure is <28 psig.

Comment:

ES-1.3, step 4.9 J Performance Step: 10 Place NaC)H Tank outlet valve switches to OPEN AOV-836A ACIV-8366 Standard: Locates, identifies and places NaOH Tank outlet valve switches to OPEN.

0 AOV-836A is open 0 AClV-836B is open Comment:

Standard: Depresses Containment Spray reset P/B.

Comment:

Page 6 of 14

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION ES-1.3, step 4.i

/, Performance Step: 12 Close discharge valves for idle CNMT spray pump(s) 0 PuinpA MOV-860A MOV-8608 0 Pump B MOV-860C MOV-860D Standard: Locates, identifies and closes discharge valves for idle CNMT spray pump stopped in Performance Step 8.

0 Pump A MOV-860A MOV-860B - Closed or Pump B MOV-860C MOV-860D - Closed Red lights off and Green lights on for closed valves.

Comment:

ES-1.3, step 5.a Performance Step: 13 Establish Adequate SW Flow:

a. Verify at least two SW pumps - RUNNING Standard: Locates arid identifies (4) Service Water Pumps running.

Red lights on and Green lights off.

Comment:

ES-1.3, S ~ O P5.b Performance Step: 14 Verify AUX BLDG SW isolation valves - OPEN 0 MCiV-4615 and MOV-4734 0 MOV-4616 and MOV-4735 Standard: Locates anld identifies AUX BLDG SW isolation valves.

0 MOV-4615 and MOV-4734 - OPEN 0 MOV-4616 and MOV-4735 - OPEN Red lights on and Green lights off.

Comment:

ES-1.3, stc!p 5.c Performance Step: 15 Determine required SW flow to CCW HXs per table:

Standard: Total of 5000 gpm - 6000 gpm equally divided to both HXs.

Normal SW Discharge alignment.

Comment:

Page 7 of 14

Appendix C Joo Performance Measure Form ES-C-1 PERFORMANCE INFORMATION ES-1.3, sbep 5.6

,/ Performance Step: 16 Direct A 0 to adjust SW flow to required value.

IF on normal SW discharge:

V-4619, CCW HX A V-4620, CCW HX B Standard: Contacts A0 to adjust Normal SW flow to a Total of 5000 gpm -

6000 gpm equally divided to both CCW HXs.

Cue: Normal SW flow is a of Total of 5500 gpm equally divided between both CCW HXs.

Comment:

ES-1.3, step 6.a

/, Performance Step: 17 Check both CCW pumps - RUNNING Standard: Locates A CCW Pump - Red light on and Green light off.

Locates B CCW Pump - Red light off and Green light on.

Identifies El CCW pump not running and goes to 6.a RNO Comment:

ES-1.3, step 6.a.l RNO (START Alternate Path)

Performance Step: 18 Start CCW pumps as power supply permits (122 kw each).

Standard: Locates arid starts B CCW Pump.

Red light off. Green light on. White light on.

Identifies El CCW pump will not start.

Comment:

ES-1.3, step 6.a.2 RNO

/, Performance Step: 19 IF both CCW pumps are running, THEN go to step 6.b.

Standard: Determine:; both CCW pumps are not running and does not go to step 6.b. Goes to RNO step 6.a.3.

Comment:

Page 8 of 14

Appendix C Jcb Performance Measure Form ES-C-1 PERFORMANCE INFORMATION ES-1.3, sl:ep 6.a.3 RNO (End Alternate Path) 4 Performance Step: 20 IF only one CCW pump is running, THEN perform the following:

a) Place NRHx temperature control valve TCV-130 to MANUAL and close valve.

b) Manually open CCW MOV to only one operable RHR loop.

Open MOV-738A or Open MOV-7386 c) Go to step 7.

Standard: Places NRHx temperature control valve TCV-130 to MANLlAL and closes valve.

Locates, identifies and opens only (1) CCW valve to one RHR Hx:

MOV-738A - open or MOV-7386 - open Red light on and Green light off for open valve.

c) Goes tcl step 7. Does not perform step 6.b.

Comment:

ES-1.3, step 7.a Performance Step: 21 Verify RHR System Alignment:

a. Verify the following valves - CLOSED o RHR suction valves from loop A hot leg MCIV-700 MCIV-701 o RHR discharge valves to loop 6 cold leg MC)V-720 MOV-721 Standard: Locates, identifies and verifies closed:

MOV-700 MCIV-701 MCIV-720 MCIV-721 Red lights off and Green lights on.

Comment:

Page 9of 14

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION ES-1.3, step 7.b Performance Step: 22 Verify RHR pump suction crosstie valves - OPEN MOV-704A MOV-704B Standard: Locates, identifies and verifies open:

MOV-704A MOV-704B Red lights on and Green lights off.

Comment:

ES-1.3, step 7.c Performance Step: 23 Verify the following valves - OPEN o RHR pump discharge to Rx vessel deluge valves MOV-852A MOV-852B o RHR sixtion from sump B (inside CNMT)

MCIV-851A MCIV-851B Standard: Locates, identifies and verifies open:

MCIV-852A MOV-852B MCIV-851A MClV-851B Red lights on and Green lights off.

Comment:

ES-1.3, step 7.d Performance Step: 24 Verify RCCIT pump suction valves from sump B - CLOSED MCIV-1813A MOV-18138 Standard: Locates, identifies and verifies closed:

MCV-1813A MOV-18138 Red lights off and Green lights on.

Comment:

!>age 1Oof 14

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION ES-1.3, step 8.a 4 Performance Step: 25 Close RW ST outlet valve to RHR pump suction, MOV-856 (turn on DC power key switch)

Standard: Locates, identifies and closes (turns on DC power key switch):

MCN-856 - Closed Red light off and Green light on.

Comment:

ES-1.3, step 8.b 4 Performance Step: 26 Open both RHR suction valves from sump B (outside CNMT)

MCW-850A - OPEN MCIV-8506 - OPEN Standard: Locates, identifies and opens:

MC)V-850A -open 0 MCN-850B -open Red lights on and Green lights off.

Comment:

ES-1.3, step 8.c (START Alternate Path)

/, Performance step: 27 Check MOV-738A AND MOV-7386 - BOTH OPEN Standard: Locates, identifies and verifies: (one valve will be shut due to only having (1) CCW pump available - Performance Step 17) 0 MCW738A -Open 0 MCW-7388 -Open Red light cln and Green light off for open valve Red light clff and Green light on for closed valve.

Goes to step 8.c RNO since both valves are not open.

Comment:

Page 11 of 14

Appendix C Job Performance Measure Form ES-C-1 PERFiORMANCE INFORMATION ES-1.3, step 8.c RNO (End Alternate Path)

/, Performance Step: 28 Perform the following:

1) IF MOV-738A open, THEN start RHR Pump A and go to step 8d.
2) IF MOV-738B open, THEN start RHR Pump B and go to step 8d.

Standard: Locates, identifies and starts:

RHR Pump A if MOV-738A is open.

RHR Purnp B if MOV-738B is open.

Red light on and Green light off for started pump.

Goes to step 8.d.

Comment:

ES-1.3, step 8.d Performance Step: 29 Start one RHR pump - ONE RHR PUMP RUNNING Standard: Locates, identifies and verifies RHR pump started in previous step is still running.

Red light on and Green light off for running pump.

Comment:

ES-1.3, step 9 Performance Step: 30 Check RWST Level - LESS THAN 15%

Standard: Locates and determines what RWST Level is.

CUE: No further action is required.

Comment:

Terminating Cue: Evaluation on this JPM is complete.

STOP TIME: TIME CRITICAL STOP TIME:

Page 12 of 14

Appendix C Job Performance Measure Form ES-C-1 VERIFICATION OF COMPLETION Job Performance Measure No.: 2008 PJRC JPM B Examinees Name:

Date Performed:

Facility Evaluator:

Number of Attempts:

Time to Complete:

Question Documentation:

Question:

Response

Result: SAT UNSAT Examiners Signature: Date:

Page 130f 14

Appendix C Job Performance Measure Form ES-C-1 JPM CUE SHEET Initial Conditions: You are the HCO.

Reactor trip with SI occurred.

The has CRS initiated loss of coolant actions RWST level is at 28% and trending down slowly.

The Control Room crew is currently at Step 22 of E-1.

Initiating Cue: The CRS directs you to transfer to Cold Leg Recirculation per ES-1.3,Transfer to Cold Leg Recirculation.

Page 14 of 14

Appendix C Job Performance Measure Form ES-C-1 Worksheet Facility: Ginna Task No.: 005-001-01-01 TasWJPM

Title:

Placing LTOP on Service JPM No.: 2008 NRC JPM C WA

Reference:

010 A4.03 4.0/3.8 Examinee: NRC Examiner:

Facility Evaluator: Date:

Method of testina:

Simulated Performance: Actual Performance: X Classroom Simulator X Plant Applicability: RO/SRO SUBMllTED BY: Ted Coe DATE: 6/30/08 Dewloper REVIEWED BY: Art Vest DATE: 6/30/08 Training Technical Reviewer REVIEWED BY: Don Dottman DATE: 6/30/08 Operations Technical Reviewer APPROVED BY: John Brown DATE: 6/30/08 Training Management Page 1 of 8

Appendix C Job Performance Measure Form ES-C-1 Worksheet Task Standard: Place PC-430 on service and all critical tasks evaluated as satisfactory.

Required Materials: (1) Panel key for LTOP operations.

General

References:

0-7, Alignment arid Operation of the Reactor Vessel Overpressure Protection System, Rev. 04701 0-2.2, Plant Shutdown from Hot Shutdown to Cold Conditions, Rev.

15000 Handouts: 0-7, Alignment and Operation of the Reactor Vessel Overpressure Protection System, Rev. 04701 Time Critical Task: NO Validation Time: 10 minutes Alternate Path: NO Instructor Notes: Ensure a marked up copy 0-7, Alignment and Operation of the Reactor Vessel Overpressure Protection System, Rev. 04701 is ready to give to the operator during the Initiating Cue.

READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.

Initial Conditions: You are an1 extra RO.

0 A unit shutldown is in progress.

0 The control room team is performing procedure 0-2.2, Plant Shutdown from Hot Shutdown to Cold Conditions and are at step 6.4.20 waiting for LTOP to be placed on service.

0 Section 1 tlirough section 6.1 of 0-7, Alignment and Operation of the Reactor Vessel Overpressure Protection System has been completed.

Initiating Cue: The Shift Manager directs you to place PCV-430 on service per 0-7, Alignment and Operation of the Reactor Vessel Overpressure Protection System section 6.2!.

CUE: Hand the Operator a marked up copy of copy 0-7, Alignment and Operation of the Reactor Vessel Overpressure Protection System, Rev. 04701.

Page 2 of 8

Appendix C Job Performance Measure Form ES-C-1 Worksheet SIMULATOR SETUP For the 2008 ILT NRC Exam load I/C # 173 or Any shutting down IC where LTOP is ready to be placed on service.

Tave is between 350°F and 330°F.

At least (1) RCP is running.

RCS pressure is -325 psig.

Properly markup a copy of 0-7, Alignment and Operation of the Reactor Vessel Overpressure Protection System, Rev. 04701 to section 6.2.

Page 3 of 8

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION START TIME:

.I= CRITICAL STEP 0-7, step 6.2.1 Performance Step: 1 VERIFY the following MCB Alarms extinguished:

AA-22, RCS OVER-PRESS PROTECTION TRAIN A HI PRESS AA-23, RCS OVER-PRESS PROTECTION TRAIN B HI PAESS AA-31, RCS OVER-PRESS PROTECTION TRAIN C HI PRESS Standard: MCB Alarrns out:

AA-22 AA-23 AA-31 Comment:

0-7, step 6.2.2

/, Performance Step: 2 ENSURE ihe PRZR PORV, PCV-430 Control Switch is in the CLOSE pcisition.

Standard: PCV-430 control switch is in the closed position.

Red light off and Green light on.

Comment:

0-7, step 6.2.3 4 Pedormance step: 3 OPEN ACCUM TO SURGE TANK VLV SOV-8616A. (MCB Rear)

Standard: Gets proper key from CRS desk.

SOV-8616A open.

Comment:

Page 4 of 8

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION 0-7, step 6.2.4 4 Performance Step: 4 ENSURE N2 ARMING VLV SOV-8619A is in the ARM position.

(MCB Rear)

Standard: Uses proper key.

SOV-8619A is in ARM.

Comment:

0-7, step 6.2.5 Performance Step: 5 VERIFY CLOSED PRZR PORV, PCV-430.

Standard: 0 PC:V-430 control switch is in the closed position.

Red light off and Green light on.

Comment:

0-7, step 6.2.6 Performance Step: 6 RECORD pressure indicated on OP ACCUM A N2 PRESSURE, PI-455.(MCB Rear)

~ Standard: Pressure recorded as shown on PI-455.

Comment:

0-7, step 6.2.7 Performance Step: 7 IF Accumulator A pressure is NOT between 735 and 760 psig, THEN CHARGE the accumulator as PER S-29.2, Charging the Reactor Vessel Overpressure Protection System Accumulators with N2.

IF Accumulator A pressure is correct, THEN MARK this Step N/A.

Standard: 0 Checks Accumulator A pressure is between 735 and 760 psig.

0 charging is not required.

0 Marks step N/A.

Comment:

Page 5 of 8

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION 0-7, step 6.2.8 Performance Step: 8 ENSURE CLOSED MOV 516 breaker, MCC C position 6C, VLV-516 RCS.

Standard: Calls A 0 to verify MOV 516 breaker is closed CUE: Acknowledge request.

REPORT: MOV 516 breaker, MCC C position 6C is closed.

Comment:

0-7, step 6.2.9 Performance Step: 9 ENSURE OPEN PRZR PORV BLOCK VLV, MOV 516.

Standard: MOV 516, PRZR P O W BLOCK VLV is open.

Red light on and Green light off.

Comment:

0-7, step 6.2.10 Performance Step: 10 RECORD the time Train A Overpressure Protection System is operable.

Standard: Records current time.

Comment:

Performance Step: 11 Reports PCV-430 is on service.

Standard: Reports PCV-430 is on service.

CUE: Acknowledge report.

Comment:

Terminating Cue: Evaluation on this JPM is complete.

STOP TIME: TIME CRITICAL STOP TIME:

Page 6 of 8

Appendix C Job Performance Measure Form ES-C-1 VERIFICATION OF COMPLETION Job Performance Measure No.: 2008 NRC JPM C Examinees Name:

Date Performed:

Facility Evaluator:

Number of Attempts:

Time to Complete:

Question Documentation:

Question:

Response

Result: SAT UNSAT Examiners Signature: Date:

Page 7 of 8

Appendix C Jclb Performance Measure JPM CUE SHEET initial Conditions: You are an extra RO.

A unit shutdown is in progress.

0 The control room team is performing procedure 0-2.2, Plant Shutdown from Hot Shutdown to Cold Conditions and are at step 6.4.20 waiting for LTOP to be placed on service.

0 Section 1 through section 6.1 of 0-7, Alignment and Operation of the Reactor Vessel Overpressure Protection System has been completed.

Initiating Cue: The Shift Manager directs you to place PCV-430 on service per 0-7, Alignment and Operation of the Reactor Vessel Overpressure Protection System section 6.2.

Page 8 of 8

Appendix C Jol) Performance Measure Form ES-C-1 Worksheet Facility: Ginna Task No.: 344-068-05-02 Task/JPM

Title:

Respond To a Control Room JPM No.: 2008 NRC JPM D Evacuation WA

Reference:

APE 068 AA1.23 4.3 / 4.4 Examinee: NRC Examiner:

Facility Evaluator: Date:

Method of testina:

Simulated Performance: Actual Performance: X Classroom Simulator X Plant Applicability: RO/SRO SUBMITTED BY: Ted Coe DATE: 6/30/08 Developer REVIEWED BY: Art Vest DATE: 6/30/08 Training Techriical Reviewer REVIEWED BY: Don Dettman DATE: 6/30/08 Operations Technical Reviewer APPROVED BY: John Brown DATE: 6/30/08 Training Management Page 1 of 8

Appendix C Job Performance Measure Form ES-C-1 Worksheet Task Standard: Immediate actions of AP-CR.1 completed from memory and all critical tasks evaluated as satisfactory.

Required Materials: None General

References:

AP-CR. 1, CONTROL ROOM INACCESSIBILITY, Rev.24 Handouts: AP-CR.1, CONTROL ROOM INACCESSIBILITY, Rev.24 Time Critical Task: NO Validation Time: 5 minutes Alternate Path: Yes Instructor Notes: Evaluator will act as the CRS for the initiating cue.

READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.

Initial Conditions: You are the HCO.

0 The CO arid the SM are in the Relay Room investigating an issue.

0 I will be thtt CRS if you need one.

0 The plant is at 100% power in a normal 50/50at power lineup.

Initiating Cue: You have the watch.

Page 2 of 8

Appendix C J o l ~Performance Measure Form ES-C-1 Worksheet SIMULATOR SETUP For the 2008 ILT NRC Exam load I/C # 174 or Any 100% IC (IC-19).

0 The plant in a normal 100% power lineup.

In a normal 50/50 electric lineup.

Insert TUR02, Turbine failure to Auto trip.

Insert TUR17A, Turbine Stop Valve: VLV 3545.

0 Insert TUR178, Turbine Stop Valve: VLV 3544.

0 Insert RPS05A, Reactor trip A breaker failure.

0 Insert RPS05B, Reactor trip B breaker failure.

A-RPS12 0 TURB12A,B,C,D A-ROD05 Page 3 of 8

Appendix C Jot) Pertormance Measure Form ES-C-1 PERFORMANCE INFORMATION START TIME:

4 = CRITICAL STEP To Evaluator: All Operator actions shall be from memory, without the aid of the procedure.

CRS Initiating Cue: Status update, Ready. (wait for response) I have just been informed there are poisonoiis fumes coming up from the Relay Room. Entering AP-CR.1, CONTROL ROOM INACCESSIBILITY. End of Update.

HCO. (wait for re:sponse, if required) Perform immediate operator actions for AP-CR.1. (wait for response) Thats correct.

AP-CR.1, step 1 (Start Alternate Path)

PerformanceStep: 1 Verify Reactor Trip:

At least one train of reactor trip breakers - OPEN.

NelJtron flux - LOWERING.

MRPl indicates - ALL CONTROL AND SHUTDOWN RODS ON BOTTOM.

Standard: Reactor is not tripped.

No reactor trip breakers are OPEN.

NelJtron flux at 100%.

MRPl indicates ALL CONTROL AND SHUTDOWN RODS are still at normal positions.

Goes to step 1 RNO.

Comment:

AP-CR.l, step 1 RNO Performance Step: 2 Manually trip reactor.

Standard: Depresses Reactor Trip Pushbutton Reactor is not tripped.

No reactor trip breakers are OPEN.

Neutron flux at 100%.

MRPl indicates ALL CONTROL AND SHUTDOWN RODS are still at normal positions.

Goes to RtJO step 1.a.

Comment:

Page 4 of 8

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION AP-CR.1, steps 1.a thru 1.d RNO 4 Performance Step: 3 IF reactor trip breakers NOT open, THEN perform the following:

a. Open Bus 13 and Bus 15 normal feed breakers.
b. Verify rod drive MG sets tripped.
c. Close Bus 13 and Bus 15 normal feed breakers.
d. Reset lighting breakers.

IF the Rx can NOT be tripped from the Control Room, THEN dispatch personnel to locally open the reactor trip breakers.

Standard: a. Opens f3us 13 and Bus 15 normal feed breakers.

0 Red lights off and Green lights on.

b. Rod drive MG sets tripped.

0 Rod Drive MG set A and B Red lights off and Green lights on.

c. Closes 13us 13 and Bus 15 normal feed breakers.

0 Red lights on and Green lights off.

d. Resets lighting breakers by depressing Bus 13 and 15 Lighting Breaker green Pushbuttons.

(ONLY a, 13 and c are critical steps. Step d is NOT a critical step.)

Comment:

AP-CR.1, step 2 Performance Step: 4 Verify Turbine Stop Valves - CLOSED Standard: On EHC v(alvestatus panel. SVL Open red light on and SVR Open red light on.

Identifies Turbine stop valves are still open and goes to step 2 RNO.

Comment:

Page 5 of 8

Appendix C Jot) Pertormance Measure Form ES-C-1 PERFORMANCE INFORMATION AP-CR.1, step 2 RNO (End Alternate Path)

Performance Step: 5 Manually trip turbine. IF turbine can NOT be tripped, THEN close both MSIVs.

Standard: Depresses Turbine Emergency Trip P/B - Turbine Does not Trip.

Closes A hSSIV and B MSlV 0 Handswitch MSlV A, AOV-3517 to close.

Handswitch MSlV 6, AOV-3516 to close.

Red lights off and Green lights on.

(Critical Stlsps are closing A and B MSIVs.)

Comment:

Completicm of Immediate Operator Actions Performance Step: 6 CRS, lmmiediate Operator Actions for AP-CR.1 are complete.

Standard: Informs CF3S that, Immediate Operator Actions for AP-CR.1 are complete.

CUE: Acknowledge report.

CUE: No further actions are required.

Comment:

Terminating Cue: Evaluation on this JPM is complete.

STOP TIME: TIME CRITICAL STOP TIME:

Page 6 of 8

Appendix C Job Performance Measure Form ES-C-1 VERIFICATION OF COMPLETION Job Performance Measure No.: 2008 t4RC JPM D Examinees Name:

Date Performed:

Facility Evaluator:

Number of Attempts:

Time to Complete:

Question Documentation:

Question:

Response

Result: SAT -- UNSAT Examiners Signature: Date:

Page 7 of 8

Appendix C Job Performance Measure Form ES-C-1 JPM CUE SHEET Initial Conditions: 0 You are the HCO.

0 The CO arid the SM are in the Relay Room investigating an issue.

0 I will be the CRS if you need one.

The plant is at 100% power in a normal 50/50at power lineup.

Initiating Cue: You have the watch.

Page 8 of 8

Appendix C Job Performance Measure Form ES-C-1 Worksheet FaciIity: Ginna Task No.: 076-004-05-01 Task/JPM

Title:

Respond to a Total ,Lossof SW JPM No.: 2008 NRC JPM E WA

Reference:

076 A2.01 3.5*/3.7*

Examinee: NRC Examiner:

Facility Evaluator: Date:

Method of testina:

Simulated Performance: Actual Performance: X Classroom Simulator X Plant Applicability: RO/SRO SUBMllTED BY: Ted Coe DATE: 6/30/08 Developer REVIEWED BY: Art Vest DATE: 6/30/08 Training Technical Reviewer REVIEWED BY: Don Dettman DATE: 6/30/08 Operations Technical Reviewer APPROVED BY: John Brown DATE: 6/30/08 Training Management Page 1 of 8

Appendix C Job Performance Measure Form ES-C-1 Worksheet Task Standard: E-0 immediate actions performed, RCPs tripped, Letdown isolated and all critical tasks evaluated as satisfactory.

Required Materials: None General

References:

AP-SW.2, LOSS OF SERVICE WATER, Rev. 00801 E-0, REACTOR TRIP OR SAFETY INJECTION, Rev. 04100 Handouts: AP-SW.2, LOSS OF SERVICE WATER, Rev. 00801 Time Critical Task: NO Validation Time: 10 minutes Alternate Path: YES Instructor Notes: Ensure a copy of AP-SW.2, LOSS OF SERVICE WATER, Rev.

00801 is ready to give to the operator during the Initiating Cue.

READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.

Initial Conditions: You are the CO.

0 I will be the CRS if you need one.

0 The plant is at 100% power in a normal 50/50electrical lineup.

0 The running Service Water pumps have just tripped.

Initiating Cue: The CRS directs you to perform AP-SW.2, LOSS OF SERVICE WATER.

CUE: Hand the Operator a copy AP-SIN.2, LOSS OF SERVICE WATER, Rev. 00801.

Page 2 of 8

Appendix C Job Performance Measure Form ES-C-1 Worksheet SIMIULATOR SETUP For the 2008 ILT NRC Exam load I/C # 175 or Any 100% IC (IC-19).

The plant in a normal 100% power lineup.

In a normal 50/50 electric lineup.

Ensure A and C Service Water pumps are running.

Insert CLGO1A, CLGO1B, CLGOlC and CLGO1D.

Ensure A and C Service Water pumps are tripped and no other SW pumps are running.

Freeze simulator and wait until the examinee takes the watch.

Page 3 of 8

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION START TIME:

d = CRITICAL STEP AP-SW.2, step 1 Performance Step: 1 Verify 480V AC Emergency Busses 17 and 18 - ENERGIZED.

Standard: Busses 17 and 18 voltage meters read -480 volts.

Normal feeds to Bus 17 and 18 are closed.

Red lights on and Green lights off.

Comment:

AP-SW.2, step 2a Performance Step: 2 Verify SW Pump Alignment:

Check at least one SW pump running in each loop:

A or B pump in loop A.

0 C or D pump in loop 8.

Standard: A and C SW Pumps Tripped (given in initial cue).

0 B a.nd D SW Pumps not running. Red lights off and Green lights on.

Recognizes no Service Water pumps running.

Go'esto step 2a RNO.

CUE: Acknowledge any report.

Comment:

AP-SW.2, step 2.a.l RNO (Start Alternate Path) .

Performance Step: 3 a. Perform the following:

1) Manually start SW pumps as necessary (257 kw each).

Standard: 0 Attctmpt to start B and D SW Pumps by taking associated control switches to Start.

0 Recognizes B and D SW Pumps trip.

0 Red lights off, White lights on and Green lights on.

May report SW pump trips to the CRS.

CUE: Acknowledge any reporl:.

Comment:

Page 4 of 8

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION AP-SW.2, step 2.a.2 RNO Performance Step: 4 IF adequate cooling can NOT be supplied to a running D/G, THEN perform the following:

a) Pull stop affected D/G.

b) Immediately depress voltage shutdown pushbutton.

Standard: D/G A and B voltmeters read 0volts. -

Recognizes no Diesel Generators are running and performs no actions.

CUE: Acknowledge any report.

Comment:

AP-SW.2, step 2.a.3.a RNO

/, Performance Step: 5 IF no SW pumps can be operated, THEN perform the following:

a) Trip the reactor.

Standard: Depresses Reactor Emergency Trip Pushbutton.

CUE: Acknowledge any report.

Comment:

AP-SW.2, step 2.a.3.b RNO

/, Performance Step: 6 WHEN all E-0 Immediate Actions done, THEN trip BOTH RCPS.

Standard: E-0Immediate Actions: (these actions performed from memory)

1. Verify Reactor Trip - Neutron flux lowering, at least one train of Reactor trip breakers open and MRPl indicates all rods are on the bottom.
2. Verifies Turbine is tripped - Turbine Stop valves are closed as indicated on EHC valve status panel. SVL Closed Green light on and SVR Closed Green light on.
3. Verify Both Trains of AC Emergency Busses energized to at least 420 volts: Busses 14,16,17 and 18 Volt-meters for Busses 14,16, 17 and 18 all read -480 VAC.
4. Check if SI is Actuated: Any SI Annunciator LIT - -

Annunciators D-19, 21, 22 and 28 extinguished and no indications that an SI is required.

Trir, both ACPs:

1. A RCF H/S to Stop Red light off and Green light on.
2. B RCP H/S to Stop Red light off and Green light on.

(Critical steps are to trip both RCPs.)

CUE: Acknowledge any report.

Comment:

Page 5 of 8

I Appendix C J o l ~Performance Measure Form ES-C-1 PERFORMANCE INFORMATION AP-SW.2, step 2.a.3.c RNO 4 Performance Step: 7 Close letdown isol, AOV-427.

Standard: ACW-427 switch in Closed.

Red light off and Green light on.

CUE: Acknowledge any report.

Comment:

AP-SW.2, step 2.a.3.d RNO (End Alternate Path)

Performance Step: 8 Close excess letdown, HCV-123.

Standard: HCV-123 is at 0% demand.

CUE: Acknowledge any report.

CUE: No further action is required.

Comment:

Terminating Cue: Evaluation on this JPM is complete.

STOP TIME: TIME CRITICAL STOP TIME:

Page 6 of 8

Appendix C JODPerformance Measure Form ES-C-1 VERIFICATION OF COMPLETION Job Performance Measure No.: 2008 NRC JPM E Examinees Name:

Date Performed:

Facility Evaluator:

Number of Attempts:

Time to Complete:

Question Documentation:

Question:

Response

Result: SAT UNSAT Examiners Signature: Date:

Page 7 of 8

Appendix C Jclb Performance Measure Form ES-C-1 JPM CUE SHEET Initial Conditions: You are the (20.

I will be the CRS if you need one.

0 The plant is at 100% power in a normal 50/50electrical lineup.

The running Service Water pumps have just tripped.

Initiating Cue: The CRS directs you to perform AP-SW.2, LOSS OF SERVICE WATER.

Page 8 of 8

Appendix C Job Performance Measure Form ES-C-1 Worksheet Facility: Ginna Task No.: 064-007-01-01A TasWJPM

Title:

Shutdown the "A" Emergency Diesel JPM No.: 2008 NRC JPM F Generator WA

Reference:

064 A4.06 3.9 / 3.9 Examinee: NRC Examiner:

Facility Evaluator: Date:

Method of testina:

Simulated Performance: Actual Performance: X Classroom Simula.tor X Plant Applicability: RO/SRO SUBMITTED BY: Ted Coe DATE: 6/30/08 D e wloper REVIEWED BY: Art Vest DATE: 6/30/08 Training Technical Reviewer REVIEWED BY: Don Dettman DATE: 6/30/08 Operations Technical Reviewer APPROVED BY: John Brown DATE: 6/30/08 Training Management Page 1 of 13

Appendix C Job Performance Measure Form ES-C-1 Worksheet Task Standard: The A D/G shutdown and all critical tasks evaluated as satisfactory.

Required Materials: None General

References:

STP-0-12.1: EMEiRGENCY DIESEL GENERATOR A, Rev. 00201 Handouts: STP-0-12.1: EMERGENCY DIESEL GENERATOR A, Rev. 00201 Time Critical Task: NO Validation Time: 20 minutes Alternate Path: NO Instructor Notes: Ensure a marked up copy of STP-0-12.1: EMERGENCY DIESEL GENERATOR A, Rev. 00201 is ready to give to the operator during the Initiating Cue.

READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.

Initial Conditions: 0 You are an extra RO.

0 The plant is at 100% power with a normal electrical lineup.

0 The A EDG is running for the monthly surveillance per STP 12.1 through Step 6.2.42.

All readings have been taken and evaluated as satisfactory.

There is an A 0 available at the A DIG.

The Diesel has run for 65 minutes, all readings have been taken.

The A 0 has the data sheets.

Bi-Annual selected Service Water Pump starts are not required.

Initiating Cue: The CRS has directed you to shutdown the A DIG per STP-0-12.1 steps 6.3 through 16.3.19.

CUE: Hand the Operator a marked up copy of STP-0-12.1, EMERGENCY DIESEL GENERATOR A, Rev. 00201.

Page 2 of 13

Appendix C Job Performance Measure Form ES-C-1 Worksheet SIMIULATOR SETUP For the 2008 ILT NRC Exam load I/C # 176 and Insert Manual Triggers 1 and 2 to reset DG1A ELCP Annunciator Panel, when requested in performance step 24.

or 100% power IC with normal electrical lineup (IC-19).

"A" D/G running at between 2025 and 2050 W per STP-0-12.1, step 6.2.36 rev. 00201.

Ensure "A" SW running and "C" SW stopped.

Ensure SW selected to "A" SW Pump.

Complete and mark up STP-0-12.1 through Step 6.2.42.

Insert Manual Triggers 1 and 2 to reset DG1A ELCP Annunciator Panel, when requested in performance step 24.

IPage 3 of 13

Appendix C Jot) Performance Measure Form ES-C-1 PERFORMANCE INFORMATION START TIME:

d = CRITICAL STEP STP-0-12.1, step 6.3.1.1 Performance Step: 1 WHEN Emergency Diesel Generator A has operated between 2025 and 2050 KW for a period of greater than 60 minutes but less than cr equal to 115 minutes, THEN UNLOAD Emergency Diesel Generator A as follows:

1. RECORD time unloading begins.

Standard: Records time unloading begins.

Comment:

STP-0-12.1, step 6.3.1.2

/, Performance Step: 2 IF the D/G A LOAD LIMIT on mechanical governor is NOT in the MAX FUEL. position, THEN PERFORM the following:

OTHERWISE, MARK this Step N/A

a. ADJUST Emergency Diesel Generator A load to between 192!5 and 1950 KW using the D/G A GOVERNOR switch AND MAINTAIN Power Factor 0.9 (lag) using the D/G A AUTO VOLTAGE CONTROL RHEOSTAT as necessary.
b. RESTORE LOAD LIMIT setting to normal (MAX FUEL).

Standard: 0 Calls the A 0 to request if LOAD LIMIT setting is at MAX FUEL.

0 Adjusts D/G A load to between 1925 and 1950 KW using the DIG A GOVERNOR switch.

0 Maintains Power Factor 0.9 (lag) using the D/G A AUTO VOLTAGE CONTROL RHEOSTAT.

0 Calls the A 0 to restore LOAD LIMIT setting to MAX FUEL.

CUE: When asked about Load Limit: LOAD LIMIT is NOT at Max Fuel.

When told to adjust Load Limit: LOAD LIMIT is now at Max Fuel.

Comment:

Page 4 of 13

Appendix C Joli Performance Measure Form ES-C-1 PERFORMANCE INFORMATION STP-O-12,,1,step 6.3.1.3 Performance Step: 3 IF the Mechanical Governor was adjusted to lock the load, THEN ADJUST Emergency Diesel Generator A load to between 2150 and 2175 KW using DIG A GOVERNOR switch AND MAlNTAlhl Power Factor at approximately 0.9 (lag) using D/G A AUTO VOLTAGE CONTROL RHEOSTAT as necessary.

OTHERWISE, MARK this Step N/A.

Standard: 0 Adjusts D/G A load to between 2150 and 2175 Kw using D/G A GOVERNOR switch.

Maintains Power Factor at approximately 0.9 (lag) using D/G A AUTO VOLTAGE CONTROL RHEOSTAT.

Comment:

STP-O-12,1, step 6.3.1.4

/, Performance step: 4 UNLOAD IEmergency Diesel Generator A; to 400 KW by intermittently turning DIG A GOVERNOR switch in the lower direction, AND MAINTAIN Power Factor at approximately 0.9 (lag) using D/G A AUTO VOLTAGE CONTROL RHEOSTAT as necessary Standard: 0 Does not violate the D/G A unloading rate of approximately 500 Kw every 30 seconds.

Unloads D/G A, to 400 KW by intermittently turning DIG A GCVERNOR switch in the lower direction.

Maintains Power Factor at approximately 0.9 (lag) using D/G A AUTO VOLTAGE CONTROL RHEOSTAT.

Comment:

STP-0-12.1 ,step 6.3.2 Performance Step: 5 IF Bi-Annual selected Service Water Pump starts are required, THEN PEFIFORM Attachment 13, Bi-Annual Service Water Pump Starts. OTHERWISE, MARK this Step AND Attachment 13 N/A.

Standard: Determine:; from Initiating Cue, not required, marks step N/A.

Comment:

Page 5 of 13

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION STP-O-12,,1,step 6.3.3 4 Performance Step: 6 WHEN Emergency Diesel Generator A load has been reduced to 400 KW, THEN TRIP one Emergency Diesel Generator A supply breaker.

Standard: 0 WHEN D/G A is at -400 KW, TRIPS one DIG A supply breaker for Bus 14 or Bus 18.

0 Green light on, red light off.

0 If Cliesel Generator Trips on Reverse Power due to operator error, the step will be evaluated as Unsat.

Comment:

STP-0-12.1, step 6.3.4 4 Performance step: 7 WHEN Errlergency Diesel Generator A load has been reduced to approximately 200 Kw AND Power Factor is 0.9 (lag), THEN TRIP the remaining closed Emergency Diesel Generator A supply breaker.

Standard: 0 WHEN D/G A load is at -200 KW and Power Factor is 0.9 (lag), TRIPS the remaining closed D/G A supply breaker for Bus 14 or Bus 18.

0 Green light on, red light off.

0 If Diesel Generator Trips on Reverse Power due to operator error, the step will be evaluated as Unsat.

Comment:

STP-0-12.1, step 6.3.5 Performance Step: 8 RECORD lime breaker was opened.

Standard: Records tirne breaker was opened.

Comment:

Page 6 of 13

Appendix C Job Performance Measure Form ES-C-1 PERFCIRMANCE INFORMATION STP-O-12:1, step 6.3.6 Performance Step: 9 IF Attachmlent 13, Bi-Annual Service Water Pump Starts, was performed, THEN ENSURE Service Water Pumps AND Selector Switches are aligned to the desired configuration.

OTHERWI!SE, MARK this Step N/A.

Standard: Determines from Initiating Cue, not required, marks step N/A.

Comment:

STP-0-12.1, step 6.3.7 4 Performance Step: OI PLACE D/G A UNIT/PARALLEL OPERATION SELECTOR switch to UNIT position.

Standard: D/G A UNlT/PARALLEL OPERATION SELECTOR switch in UNIT positiion.

Comment:

STP-0-12.1, Step 6.3.8 4 Performance Step: 11 PLACE D/G A SYNCHROSCOPE switch in the BUS 14 or BUS 18 position.

Standard: D/G A SYNCHROSCOPE switch in the BUS 14 or BUS 18 position.

Comment:

STP-0-12.1, step 6.3.9 Performance Step: 12 IF Emergeiicy Diesel Generator A frequency is high, THEN OPERATE D/G A GOVERNOR switch to return to a setting of between 60 and 60.1 Hertz (revolving slowly in the clockwise direction) AND TRANSFER frequency setting data to Attachment 3, As Found/As Left Voltage and Frequency.

OTHERWISE, MARK this Step N/A.

Standard: Determines frequency is satisfactory, marks step N/A.

Comment:

Page 7 of 13

- ~ ~~ ~~ ~~

Appendix C Jot) PerformanceMeaGre Form ES-C-1 PERFORMANCE INFORMATION STP-0-12.1, step 6.3.10 4 Performance Step: 13 PLACE D/G A SYNCHROSCOPE switch to the OFF position.

Standard: D/G A SYNCHROSCOPE switch in off.

Comment:

STP-0-12.1, step 6.3.1 1 Performance Step: 14 MEASURE! the Emergency Diesel Generator A speed using a photo-tachometer, AND RECORD speed data on Attachment 3, As Found/& Left Voltage and Frequency.

Standard: 0 Directs the A 0 to measure the D/G A speed using a Photo-tachometer.

0 Records the speed data on Attachment 3.

CUE: A D/G speed is 900 rpm.

Comment:

STP-0-12.1, step 6.3.1 2 Performance Step: 15 ADJUST CVG A AUTO VOLTAGE CONTROL RHEOSTAT to establish Emergency Diesel Generator A output voltage between 480 and 490 Volts (adjust as close to 480 volts as possible) AND RECORD voltage data on Attachment 3, As FoundAs Left Voltage and Frequency.

Standard: D/Ci A output voltage between 480 and 490 Volts.

Records voltage data on Attachment 3.

Comment:

STP-0-12.1, step 6.3.13 Performance Step: 16 RECORD the as left D/G A AUTO VOLTAGE CONTROL RHEOSTAT position on Attachment 14, Auto Voltage Control Rheostat After Start - As Left, by sketching in the dial setting.

Standard: Sketching in the dial setting on Attachment 14.

Comment:

Page 8 of 13

Appendix C Jot) Performance Measure Form ES-C-1 PERFORMANCE INFORMATION STP-0-12.1, step 6.3.14 4 Performance Step: 17 TURN the D/G A CONTROL switch to the STOP position.

Standard: D/G A CONTROL switch to STOP then spring returns to mid position (red flagged).

Comment:

STP-0-12.1, step 6.3.15

,/ Performance Step: 18 PUSH ANI) HOLD the D/G A VOLTAGE SHUTDOWN button (Black button) for a few seconds immediately after stopping Emergency Diesel Generator A.

Standard: Pushes and holds the DIG A VOLTAGE SHUTDOWN button for a few seconds immediately after stopping D/G A.

CUE: If requested, report as the AO, AD/G has stopped.

Comment:

STP-0-12.1, step 6.3.1 6

/, Performance Step: 1g WHEN the Emergency Diesel Generator A has stopped rolling, THEN PUSH the following buttons:

D/GA RESET 0 D/G A FIELD RESET Standard: DIG A RESET button depressed.

DIG A FIELD RESET button depressed.

CUE: If requested, report as the AO, A DIG has stopped.

Comment:

Page 9 of 13

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION STP-0-12.1 , step 6.3.17 Performance Step: 20 WHEN the Emergency Diesel Generator A is reset, THEN VERIFY the following indicating lamps are illuminated (MCB Rear):

0 AlFi START SOLENOID VALVE 1 POWER AVAILABLE AlFi START SOLENOID VALVE 2 POWER AVAILABLE 0 START RELAY 1 POWER AVAILABLE START RELAY 2 POWER AVAILABLE Standard: Verifies the following indicating lamps are illuminated:

0 AlFt START SOLENOID VALVE 1 POWER AVAILABLE 0 AlFl START SOLENOID VALVE 2 POWER AVAILABLE START RELAY 1 POWER AVAILABLE 0 START RELAY 2 POWER AVAILABLE Comment:

STP-0-12.1,step 6.3.18 Performance Step: 21 DECLARE, Emergency Diesel Generator A unavailable.

Standard: Informs the CRS/HCO A D/G is unavailable.

CUE: Acknowledge report.

Comment:

STP-0-12.1 ,step 6.3.19.1 Performance Step: 22 VERIFY DIG A CONTROL switch reset alarm operability as follows:

1. VERIFY no other alarm condition exists on the Emergency Diesel Generator A alarm panel.

Standard: No alarms.

CUE: If requested, report as the AO, no other alarm condition exists on the Emergency Diesel Generator A alarm panel.

Comment:

Page 10 of 13

Appendix C Jot) Performance Measure Form ES-C-1 PERFORMANCE INFORMATION STP-0-12.1, step 6.3.1 9.2

,/ Performance Step: 23 PLACE DPS A CONTROL switch in the PULL STOP position AND VERIFY the following:

MCB Alarm J-24, EMERGENCY DIESEL GEN 1A PANEL, is illuminated.

0 Emergency Diesel Generator A START RELAY 1 POWER AVAILABLE AND START RELAY 2 POWER AVAILABLE lights are extinguished (MCB).

Standard: D/G A CONTROL switch in PULL STOP.

MCB Alarm J-24, EMERGENCY DIESEL GEN 1A PANEL, is illuminated.

0 Emergency Diesel Generator A START RELAY 1 POWER AVAILABLE AND START RELAY 2 POWER AVAILABLE lights are extinguished (MCB).

Comment:

STP-0-12.1, step 6.3.1 9.3 Performance Step: 24 DEPRESS ACK button at DGlA ELCP Annunciator Panel AND VERIFY Ernergency Diesel Generator A shutdown reset annunciator (R3) is illuminated.

Standard: Contacts A 0 to perform step 6.3.1 9.3.

CUE: Acknowledge request.

Simulator Operator: Insert Manual Triggers 1 and 2 to reset DGlA ELCP Annunciator Panel.

CUE: ACK button at DGlA ELCP Annunciator Panel has been depressed and (R3) is illuminated.

Comment:

Terminating Cue: Evaluationi on this JPM is complete.

STOP TIME: TIME CRITICAL STOP TIME:

Page 11 of 13

Appendix C Job Performance Measure Form ES-C-1 VERIFICATION OF COMPLETION -

Job Performance Measure No.: 2008 FJRC JPM F Examinees Name:

Date Performed:

Facility Evaluator:

Number of Attempts:

Time to Complete:

Question Documentation:

Question:

Response

Result: SAT UNSAT Examiners Signature: Date:

Page 12 of 13

Appendix C Job Performance Measure Form ES-C-1 JPM CUE SHEET Initial Conditions: 0 You are an extra RO.

0 The plant is at 100% power with a normal electrical lineup.

e The A EIIG is running for the monthly surveillance per STP 12.1 through Step 6.2.42.

All readings have been taken and evaluated as satisfactory.

There is a i A 0 available at the A D/G.

The Diesel has run for 65 minutes, all readings have been taken.

The A 0 has the data sheets.

Bi-Annual selected Service Water Pump starts are not required.

Initiating Cue: The CRS has directed you to shutdown the A D/G per STP-0-12.1 steps 6.3 through 6.3.1 9.

Page 13 of 13

Appendix C Jot) Performance Measure Form ES-C-1

- ~

Worksheet Facility: Ginna Task No.: 015-007-01-01A TasWJPM

Title:

Remove a Power Range Channel JPM No.: 2008 NRC JPM G from Service.

WA

Reference:

015 A2.02 3.1 / 3.5*

Examinee: NRC Examiner:

Facility Evaluator: Date:

Method of testina:

Simulated Performance: Actual Performance: X Classroom Simulator X Plant Applicability: RO/SRO SUBMITTED BY: Ted Coe DATE: 6/30/08 Developer REVIEWED BY: Art Vest DATE: 6/30/08 Training Technical Reviewer REVIEWED BY: Don Dettman DATE: 6/30/08 Operations Technical Reviewer APPROVED BY: John Blrown DATE: 6/30/08 Training Management Page 1 of 13

Appendix C Job Performance Measure Form ES-C-1 Worksheet Task Standard: Remove N-41 from service and all critical tasks evaluated as satisfactory.

Required Materials: None General

References:

ER-NIS.3, PR Malfunction, Rev. 26 Handouts: ER-NIS.3, PR Malfunction, Rev. 26 Time Critical Task: NO Validation Time: 19 minutes Alternate Path: NO Instructor Notes: Ensure a marked up copy of ER-NIS.3, PR Malfunction, Rev. 26 is ready to give to the operator during the Initiating Cue.

READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues.

When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.

Initial Conditions: You are an extra RO.

Power Range channel N-41 drifted low over a period of several minutes and has been declared inoperable.

No plant transient has occurred.

Procedure ER-NIS.3 is being implemented.

Reactor power is 100%.

No other channels have been defeated.

Initiating Cue: The CRS has directed you to remove PR N-41 from service per ER-NIS.3.

Step 4.4 Attachmtant N-41 Defeat.

All notifications ha.ve been made and approvals received.

CUE: Hand the Operator a marked up copy of ER-NIS.3, PR Malfunction, Rev. 26.

Page 2 of 13

Appendix C Job Performance Measure Form ES-C-1 Worksheet SlhAULATOR SETUP For the 2008 ILT NRC Exam load I/C # 177 or Select IC 19 (or any full power IC).

Place Rods in manual.

Place N-41 to Rod Drop Bypass, reduce gain to 0.

Return Rod Drop Bypass to Norrrial.

Adjust Tave = Tref.

Page 3 of 13

Appendix C Jab Performance Measure Form ES-C-1 PERFORMANCE INFORMATION START TIME:

.\I = CRITICAL STEP ER-NIS.3, Att. N-41 Defeat, step 1 4 Performance step: 1 IF the PPCS is operational, THEN delete NIS Channel 41 from processing by performing the following:

a. Sekct Group Update display.
b. Select List Server Groups.
c. Select NIS1 from the pick list.
d. Turn OFF scan processing, then click the Set Scan Processing button.
e. Answer prompts.

Standard: Deletes NIS Channel 41 from processing by performing the following:

0 Selects Group Update display.

0 Selects List Server Groups.

0 Selects NIS1 from the pick list.

0 Turns OFF scan processing, then clicks the Set Scan Processing button.

0 Answers prompts.

Comment:

ER-NIS.3, Att. N-41 Defeat, step 2 Performance Step: 2 Verify the ROD CONTROL BANK SELECTOR switch (MCB) is in the M (MAiNUAL) position.

Standard: ROD CONTROL BANK SELECTOR switch is selected to MANUAL.

Comment:

Page 4 of 13

Appendix C Jclb Performance Measure Form ES-C-1 PERFORMANCE INFORMATION ER-NIS.3, Att. N-41 Defeat, step 3 Performance Step: 3 Place the DROPPED ROD MODE switch (Power Range N41A drawer) to BYPASS AND verify the following:

DFlOPPED ROD BYPASS (local light) is lit.

0 POWER RANGE-1 ROD DROP BYPASS (MCB bypass stalus light) is lit.

0 Annunciator (MCB) E-7, NIS TRIP BYPASS, is lit.

Standard: Places the DROPPED ROD MODE to BYPASS AND verifies:

0 DFlOPPED ROD BYPASS (local light) is lit.

0 PCIWER RANGE-1 ROD DROP BYPASS (MCB bypass status light) is lit.

0 Annunciator (MCB) E-7, NIS TRIP BYPASS, is lit.

Comment:

ER-NIS.3, Att. N-41 Defeat, step 4 4 Pertormance Step: 4 Place T/405E DELTA T DEFEAT switch (RIL Insertion Limit Rack) to LOOP A UNIT 1 (Defeats the delta T Runback and Rodstop for the failed channel AND removes the associated delta-T input from the RIL computer-Annunciators F-30 AND F-31 will clear if lit).

Standard: Places T/405E DELTA T DEFEAT switch (RIL Insertion Limit Rack) to LOOP A UNIT 1 Annunciators F-30 AND F-31 will clear if lit.

Comment:

Page 5 of 13

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION ER-NIS.3, Att. N-41 Defeat, step 5 4 Performance Step: 5 Place the OVERTEMP TRIP bistable (Red R-1 Protection Channel 1 rack) proving switch to DEFEAT (UP) AND verify the following:

0 Annunciator F-23, RCS 0T)T CHANNEL ALERT, is lit 0 Proving light OFF if TI-4058 > or = TI-405A IF any proving light status is NOT correct, THEN submit an ACTION Fleport on the discrepancy and continue with the channel defeat steps.

Standard: Places the OVERTEMP TRIP bistable proving switch to DEFEAT (UP) AND verifies the following:

0 Annunciator F-23,RCS OT delta-T CHANNEL ALERT, is lit 0 Proving light OFF if TI-4058 > or = Ti-405A Comment:

ER-NIS.3, Att. N-41 Defeat, step 6

/, Performance Step: 6 Place the OVERPOWER TRIP bistable (Red R-1 Protection Channel 1 rack) proving switch to DEFEAT (UP) AND verify the following:

Annunciator F-32,RCS OP delta-T CHANNEL ALERT, is lit 0 Proving light OFF if TI-405B > or = TI-405C IF any proving light status is NOT correct, THEN submit an ACTION Report on the discrepancy and continue with the channel defeat steps.

4 Standard: Places the OVERPOWER TRIP bistable proving switch to DEFEAT (IJP) AND verifies the following:

0 Anriunciator F-32, RCS OP delta-T CHANNEL ALERT, is lit 0 Proving light OFF if TI-4058 > or = TI-405C Comment:

Page 6 of 13

Appendix C Jot) Performance Measure Form ES-C-1 PERFORMANCE INFORMATION ER-NIS.3, Att. N-41 Defeat, step 7 Performance Step: 7 Verify the following bistables are lit:

a. TC405A OP Delta T LOODA
b. TC405C OT Delta T Loop A Standard: Verifies bistables are lit:
a. TC405A OP Delta T Loop A
b. TC405C OT Delta T Loop A Comment:

ER-NIS.3, Att. N-41 Defeat, step 8 4 Performance Step: 8 Place the lJPPER SECTION DEFEAT switch (Detector Current Comparator- Miscellaneous Control & Indications drawer) to the PRN41 position AND verify the following:

Local light for CHANNEL DEFEAT upper section is lit.

Standard: Places the UPPER SECTION DEFEAT switch to the PRN41 position AND verifies:

Local light for CHANNEL DEFEAT upper section is lit.

Comment:

ER-NIS.3, Att. N-41 Defeat, step 9 4 Performance Step: g Place the LOWER SECTION DEFEAT switch (Detector Current Comparator-MiscellaneousControls & Indications drawer) to the PRN41 position AND verify the following:

Local light for CHANNEL DEFEAT lower section is lit.

Standard: Places the LOWER SECTION DEFEAT to the PRN41 position AND verifies:

Local light for CHANNEL DEFEAT lower section is lit.

Comment:

Page 7 of 13

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION ER-NIS.3, Att. N-41 Defeat, step 10 4 Performance Step: 10 Place the POWER MISMATCH BYPASS switch (Detector Current CDmparator-MiscellaneousControls & Indications drawer) tc BYPASS PR N41.

Standard: Places the POWER MISMATCH BYPASS to BYPASS PR N41.

Comment:

ER-NIS.3, Att. N-41 Defeat, step 11 I/ Performance Step: 11 Place the ROD STOP BYPASS switch (Detector Current Comparator-MiscellaneousControls & Indications drawer) to BYPASS PR N41.

Standard: Places the ROD STOP BYPASS switch to BYPASS PR N41.

Comment:

ER-NIS.3, Att. N-41 Defeat, step 12 4 Performance Step: 12 Place the COMPARATOR CHANNEL DEFEAT switch (Cornparalor and Ratedrawer) to N41 AND verify the following:

Local light for COMPARATOR DEFEAT is lit.

Standard: Places the COMPARATOR CHANNEL DEFEAT switch to N41 AND verifies:

Local light for COMPARATOR DEFEAT is lit.

Comment:

Page 8 of 13

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION ER-NIS.3, Att. N-41 Defeat, step 13 4 Performance Step: 13 Remove the 118V 5A AC INSTR POWER fuses (Power Range N41B drawer) AND verify the following alarms (MCB) are lit:

E-l8, POWER RANGE LOSS OF DETECTOR VOLTAGE E-l9, POWER RANGE HI RANGE CHANNEL ALERT 1013%

E-21, POWER RANGE OVERPOWER ROD STOP 103%

E-27, POWER RANGE LO RANGE CHANNEL ALERT 24%

E-;!8, POWER RANGE ROD DROP ROD STOP -5/0/5 SEC Standard: Removes ,the 118V 5A AC INSTR POWER fuses (Power Range N41B drawer) AND verifies the following alarms (MCB) are lit:

E-18, POWER RANGE LOSS OF DETECTOR VOLTAGE E-19, POWER RANGE HI RANGE CHANNEL ALERT 1Ot3%

E-Z!l, POWER RANGE OVERPOWER ROD STOP 103%

E-27, POWER RANGE LO RANGE CHANNEL ALERT 24%

E-28, POWER RANGE ROD DROP ROD STOP -5%/5 SEC Comment:

ER-NIS.3, Att. N-41 Defeat, step 13.1 Performance Step: 14 Verify the following red bistable lights (MCB) are lit:

HI IOW RANGE P-10 NC41M HI IOW RANGE P-8 NC41N LO POW RANGE TRIP NC41P HI POW RANGE TRIP NC41R HI IOW RANGE P-9 NC41S IF any bistiable above is NOT lit, THEN the channel may not be in the tripped.

Standard: Verifies the following red bistable lights (MCB) are lit:

HI POW RANGE P-10 NC41M HI POW RANGE P-8 NC41N 0 LO POW RANGE TRIP NC41P 0 HI POW RANGE TRIP NC41R HI POW RANGE P-9 NC41S Comment:

Page 9 of 13

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION ER-NIS.3, Att. N-41 Defeat, step 13.2 Performance Step: 15 Verify the following status lights (Power Range N41A drawer) are lit:

0 CONTROL POWER ON 0 LOSS OF DETECTOR VOLT OVERPOWER TRIP HIGH RANGE OVERPOWER ROD STOP 0 OVERPOWER TRIP LOW RANGE 0 POWER ABOVE PERMISSIVE P10 0 POWER ABOVE PERMISSIVE P8 0 POWER ABOVE PERMISSIVE P9 0 DROPPED ROD ROD STOP 0 DROPPED ROD BYPASS Standard: Verifies the following status lights (Power Range N41A drawer) are lit:

CCINTROL POWER ON LOSS OF DETECTOR VOLT 0 OLERPOWER TRIP HIGH RANGE OVERPOWER ROD STOP 0 OVERPOWER TRIP LOW RANGE 0 PCIWER ABOVE PERMISSIVE P10 PClWER ABOVE PERMISSIVE P8 0 POWER ABOVE PERMISSIVE P9 DROPPED ROD ROD STOP 0 DROPPED ROD BYPASS Comment:

ER-NIS.3, Att. N-41 Defeat, step 13.3 Performance Step: 16 Verify the following status lights (Power Range N41B drawer) are extinguished:

INSTRUMENT POWER ON 0 CHANNEL ON TEST Standard: Verifies the following status lights (Power Range N41B drawer) are extinguished:

0 INSTRUMENT POWER ON CHANNEL ON TEST Comment:

Fage 10 of 13

Appendix C Jclb Performance Measure Form ES-C-1 PERFORMANCE INFORMATION ER-NIS.3, Att. N-41 Defeat, step 14 Performance Step: 17 Notify I&C to install jumpers across contacts 1-5 AND 4-8 of Power Range relays NC 41 MX (both A train and B train Protection Racks). This will remove N-41 from the logic circuit for reinstating the PR low power trip and the source ranges (P-10).

Standard: Notifies I&C to install jumpers across contacts 1-5 AND 4-8 of Power Range relays NC 41 MX (both A train and B train Protection Racks).

CUE: Acknowledge request.

Comment:

ER-NIS.3, Att. N-41 Defeat, step 15 Performance Step: 18 Initiate an A-52.4 on N-41.

Standard: Initiates an A-52.4 on N-41 or informs CRS to initiate A-52.4.

CUE: CRS has initiated an A-52.4 for NI-41.

Comment:

ER-NIS.3, Att. N-41 Defeat, step 16 Performance Step: 19 Go to step 4-5.

Standard: Goes to stlzp 4.5.

CUE: CRS will continue at step 4.5.

Comment:

. Terminating Cue: Evaluatiori on this JPM is complete.

STOP TIME: TIME CRITICAL STOP TIME:

Page 11 of 13

Appendix C Jclb Performance Measure Form ES-C-1 VERIFICATION OF COMPLETION Job Performance Measure No.: 2008 I W C JPM G Examinees Name:

Date Performed:

Facility Evaluator:

Number of Attempts:

Time to Complete:

Question Documentation:

Question:

Response

Result: SAT UNSAT Examiners Signature: Date:

Fage 12 of 13

Appendix C Jab Performance Measure Form ES-C-1 JPM CUE SHEET Initial Conditions: You are an extra RO.

0 Power Range channel N-41 drifted low over a period of several minutes and has been declared inoperable.

0 No plant t ?ansienthas occurred.

0 Procedure ER-NIS.3 is being implemented.

Reactor pDwer is 100°/o.

0 No other channels have been defeated.

Initiating Cue: The CRS has directed you to remove PR N-41 from service per ER-NIS.3.

Step 4.4 Attachment N-41 Defeat.

All notifications have been made and approvals received.

Page 13 of 13

Appendix C Job Performance Measure Form ES-C-1 Worksheet Facility: Ginna Task No.: 029-004-01-01A TasWJPM

Title:

Shutdown Containment Purge JPM No.: 2008 NRC JPM H WA

Reference:

APE 036 AA1.O1 3.313.8 Examinee: NRC Examiner:

Facility Evaluator: Date:

Method of testina:

Simulated Performance: Actual Performance: X Classroom Simulator X Plant Applicability: RO/SRO SUBMITTED BY: Ted Coe DATE: 6/30/08 Developer REVIEWED BY: Art Vest DATE: 6/30/08 Training Technical Reviewer REVIEWED BY: Don Dettman DATE: 6/30/08 Operations Technical Reviewer APPROVED BY: John Brown DATE: 6/30/08 Training Management Page 1 of 7

vdix C Job Performance Measure Form ES-C-1 Worksheet Task Standard: The Containmerit Purge shutdown and all critical tasks evaluated as satisfactory.

Required Materials: None General

References:

S-23.2.2, Containment Purge Procedure, Rev. 04801 Handouts: S-23.2.2, Containment Purge Procedure, Rev. 04801 Time Critical Task: NO Validation Time: 5 minutes Alternate Path: NO Instructor Notes: Ensure a marked up copy of S-23.2.2, Containment Purge Procedure, Rev. 04801 is rea.dy to give to the operator during the Initiating Cue.

READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.

Initial Conditions: You are an extra RO.

The plant is in cold shutdown.

0 A Containment Purge is in progress.

The Refuel SRO has requested Containment Purge be secured due to a Rt?fuelingIncident.

RP has authorized securing the purge.

Initiating Cue: The Shift Manager directs you to secure the Containment Purge per Step 6.3of S-23.2.2.

CUE: Hand the Operator a marked up (copyof S-23.2.2, Containment Purge Procedure, Rev. 04801.

Page 2 of 7

Appendix C Job Performance Measure Form ES-C-1 Worksheet

-SIMIULATOR SETUP For the 2008 ILT NRC Exam load I/C ## 178 or 0 Any cold shutdown IC.

0 Remove purge flanges, MIS78.

0 Place purge system in service with both fans running.

0 S-23.2.2 signed off up to section 6.3.

Page 3 of 7

Appendix C Joo Performance Measure Form ES-C-1 PERFORMANCE INFORMATION START TIME:

d = CRITICAL STEP S-23.2.2, step 6.3.1 4 Performance Step: 1 STOP Containment Purge Supply and Exhaust Fans A if running. OTHERWISE MARK this step N/A.

Standard: Switch to stop. Red lights off, Green lights on.

Comment:

S-23.2.2, step 6.3.2 4 Performance Step: 2 STOP Containment Purge Supply and Exhaust Fans B if running OTHERWISE MARK this step N/A.

Standard: Switch to stop. Red lights off, Green lights on.

Comment:

S-23.2.2, step 6.3.4 4 Performance step: 3 CLOSE Containment Purge Supply Valve V-5869.

Standard: Switch to c:lose. Red light off, Green light on.

Comment:

S-23.2.2, step 6.3.4 4 Performance Step: 4 CLOSE Cclntainment Purge Exhaust Valve V-5879.

Standard: Switch to close. Red light off, Green light on.

Comment:

Page 4 of 7

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION S-23.2.2, step 6.3.5 Performance Step: 5 LOG information on Containment Purge Release Permit.

Standard: Logs information on Containment Purge Release Permit.

CUE: The HCO will do that.

Comment:

Terminating Cue: Evaluation on this JPM is complete.

STOP TIME: TIME CRITICAL STOP TIME:

Page 5 of 7

Appendix C Job Performance Measure Form ES-C-1 VERIFICATION OF COMPLETION Job Performance Measure No.: 2008 NRC JPM H Examinees Name:

Date Performed:

Facility Evaluator:

Number of Attempts:

Time to Complete:

Question Documentation:

Question:

Response

Result: SAT UNSAT Examiners Signature: Date:

Page 6 of 7

Appendix C Job Performance Measure Form ES-C-1 JPM CUE SHEET Initial Conditions: You are an extra RO.

The plant is in cold shutdown.

A Containment Purge is in progress.

0 The Refuc?iSRO has requested Containment Purge be secured due to a Flefueling incident.

RP has authorized securing the purge.

initiating Cue: The Shift Manager directs you to secure the Containment Purge per Step 6.3 of S-232.2.

Page 7 of 7

Appendix C Job Performance Measure Form ES-C-1 Worksheet ~

Facility: Ginna Task No.: 001-007-01-04A Task/JPM

Title:

Startup and Parallel Rod Drive MG JPM No.: 2008 NRC JPM I Set (Parallel Fails)

WA

Reference:

001 A4.0 8 3.7 / :3.4 Examinee: NRC Examiner:

Facility Evaluator: Date:

Method of testing:

Simulated Performance: X Actual Performance:

Classroom Simulator Plant X Applicability: RO/SRO SUBMITTED BY: Ted Coe DATE: 6/30/08 Developer REVIEWED BY: Art Vest DATE: 6/30/08 Training Technical Reviewer REVIEWED BY: Don Dettman DATE: 6/30/08 Operations Technical Reviewer APPROVED BY: John Brown DATE: 6/30/08 Training Management Page 1 of 13

Appendix C Job Performance Measure Form ES-C-1 Worksheet Task Standard: MG sets paralleled and all critical tasks evaluated as satisfactory.

Required Materials: Proper Noise Protection, Hard Hat, Safety Glasses, Safety Shoes, Leather Gloves.

General

References:

S-1A, Startup of Fbd Drive Motor Generator Sets, Rev.18 Handouts: S-1A, Startup of Rod Drive Motor Generator Sets, Rev.18 Time Critical Task: NO Validation Time: 20 minutes Alternate Path: YES Instructor Notes: Ensure Proper IJoke Protection, Hard Hat, Safety Glasses, Safety Shoes and leather gloves are worn as required.

Ensure a marked up copy of S-1A, Startup of Rod Drive Motor Generator Sets, Rev.18 is ready to give to the operator during the Initiating Cue.

READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.

Initial Conditions: 0 You are an extra RO.

0 Preparations fw startup of Rod Control System are under way.

The 18 MG set is running.

Initiating Cue: The Shift Manager directs you to startup and parallel the 1A Rod Drive MG Set per S-1A section 5.3.

Simulate all activities - DO NOT MANIPULATE ANY EQUIPMENT.

CUE: Hand the Operator a marked up copy of S-1A, Startup of Rod Drive Motor Generator Sets, Rev.18.

Page 2 of 13

~

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION START TIME:

4 = CRITICAL STEP S-1A, step 5.3.1 Performance Step: 1 One MG set is running and carrying a steady electrical load.

Standard: Verifies 1E3 MG set is running. Given in initial cue.

CUE: 1B MG set is running, carrying a steady electrical load. 1A MG set is secured, Comment:

S-1A, step 5.3.2 Performance step: 2 Verify remaining motor generator set ALARM BYPASS switch is in the BYPASS position.

Standard: Verifies 1A MG set ALARM BYPASS switch is in the BYPASS position.

CUE: 1A MG set ALARM BYPASS switch is in the BYPASS position.

Comment:

S-1A, step) 5.3.3 Performance Step: 3 Verify the remaining Motor Generator set VOLTAGE ADJUST in full counter-clockwise position.

Standard: 1A MG set VOLTAGE ADJUST is in full counter-clockwise position.

CUE: 1A MG set VOLTAGE ADJUST is in full counter-clockwise position.

Comment:

S-1 A, step 5.3.4.1

/, Performance Step: 4 Rotate the MOTOR NO. 1A CIRCUIT BREAKER CONTROL switch to CLOSE.

Standard: Identifies the MOTOR NO. 1A CIRCUIT BREAKER CONTROL switch, and simulates rotating to CLOSE.

CUE: Component is in desired position.

Comment:

Page 3 of 13

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION CUE: Motor is at full speed.

S-lA, step 5.3.4.2

/, Performance Step: 5 WHEN motor is at full speed, THEN depress AND hold the FIELD FLASH pushbutton.

Standard: Identifies FIELD FLASH pushbutton, and generator voltage indication (OUTPUT AC VOLTAGE METER).

Simulate depressing and holding FIELD FLASH pushbutton.

CUE: Component is in desired condition.

Comment:

S-1A, step 5.3.4.3

,,/ Performance step: 6 WHEN Gmerator voltage has risen to > 234 volts AND is NOT increasing, THEN release the FIELD FLASH pushbutton.

Standard: Simulates FIELD FLASH pushbutton released.

CUE: Generator voltage has risen to 250 volts AND is steady.

CUE: Component is in desired condition.

Comment:

S-1A, step 5.3.4.4

/, Performance step: 7 Rotate the VOLTAGE ADJUST potentiometer clockwise UNTIL voltage is 260.

Standard: Rotates the VOLTAGE ADJUST potentiometer clockwise UNTIL voltage is ;!60.

CUE: Generator voltage has risen slowly to 260 volts.

Comment:

S-1A, step 5.3.5 Performance step: 8 Verify FIELD CURRENT is ~ 1 . amps 2 AND ~ 4 . amps 8 as read on the FIELD CURRENT METER.

Standard: Identifies FIELD CURRENT METER.

CUE: FIELD CURRENT is as read.

Comment:

Page 4 of 13

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION S-1A, step 5.3.6 Performance Step: g Verify FIELD CURRENT alarm has cleared. (Alarm LED is located or1 the FIELD CURRENT METER)

Standard: Identifies alarm LED on the FIELD CURRENT METER is out.

CUE: Alarm LED on the FIELD CURRENT METER is out.

Comment:

S-1A, step 5.3.7 Performance Step: 10 Place ALARM BYPASS switch in the "ACTIVE position.

Standard: Identifies ALARM BYPASS switch and simulates placing in "ACTIVE",

CUE: Component is in desired position.

Comment:

S-1A, step 5.3.8 Performance step: 11 Verify MC13 annunciator C-21 (Rod Control MG Set Trouble) is extinguished.

Standard: Contacts control room on status of (3-21.

CUE: C-21, (Rod Control MG Se!t Trouble) is extinguished.

Comment:

S-1A, step 5.3.9

/, Performance Step: 12 Rotate the synchronize switch to ON (on the MG set being started) AND allow a few seconds for the synchronizer to warm UP-Standard: Rotates tht? 1A synchronize switch to ON (AND allows a few seconds for the synchronizer to warm up.

CUE: Component is in desired position.

Comment:

Page 5 of 13

Appendix C Jcb Performance Measure Form ES-C-1 PERFORMANCE INFORMATION S-1A, step 5.3.10.1

/, Performance Step: 13 Observe tne Synchroscope (Syn/CRDMGAB) for indication when the two generators are in sync and trip the on-coming M/G Set Motor Breaker by rotating the circuit breaker control handle to the TRIP POSITION just after the Synchronizing Point (approximately 3 minutes after 12).

Standard: Observes the Synchroscope for indication when the two generators are in sync and trips the 1A M/G Set Motor Breaker by rotating the circuit breaker control handle to the TRIP POSITION just after the Synchronizing Point (approximately 3 minutes after 12).

CUE: Component is in desired position.

CUE: It has been 30 seconds and the Synchroscope indicates the two generators are not in parallel.

Comment:

S-1A, step 5.3.1 0.2

/, Performance step; 14 Should the Generator fail to parallel within 30 seconds, THEN return the synchronize switch to OFF, AND proceed with steps 5.3.1 through 5.3.10 again. N/A if generator paralleled.

Standard: Synchroniiie switch to OFF.

Returns to step 5.3.1.

CUE: Synchroscope indicates tlhe two generators are not in parallel.

CUE: Component is in desired position.

Comment :

S-1A, step 5.3.1 (Start Alternate Path)

Performance Step: 15 One MG set is running and carrying a steady electrical load.

Standard: Verifies 19 MG set is running. Given in initial cue.

CUE: 1B MG set is running, carrying a steady electrical load.

Comment:

S-1A, step 5.3.2 Performance Step: 16 Verify remaining motor generator set ALARM BYPASS switch is in the BYPASS position.

Standard: Places 1A bAG set ALARM BYPASS switch in the BYPASS position.

CUE: 1A MG set ALARM BYPAS!3 switch is in the BYPASS position.

Page 6 of 13

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION Comment:

S-1A, step 5.3.3 Performance step: 17 Verify the remaining Motor Generator set VOLTAGE ADJUST in full counter-clockwise position.

Standard: Adjusts 1A MG set VOLTAGE ADJUST to the full counter-clockwise position.

CUE: 1A MG set VOLTAGE AD,IUST is in full counter-clockwise position.

Comment:

S-1A, step 5.3.4.1

,/ Pedormance step: 18 Rotate the MOTOR NO. 1A CIRCUIT BREAKER CONTROL switch to CLOSE.

Standard: Identifies switch, and simulate rotating to CLOSE.

CUE: Component is in desired position.

Comment:

CUE: Motor is at full speed.

S-1A, step 5.3.4.2

,/ Performance Step: 19 WHEN motor is at full speed, THEN depress AND hold the FIELD FLASH pushbutton.

Standard: Identifies FIELD FLASH pushbutton, and generator voltage indication (OUTPUT AC VOLTAGE METER).

Simulate depressing and holding FIELD FLASH pushbutton.

CUE: Component is in desired condition.

Comment:

S-1A, step 5.3.4.3

/, Performance step: 20 WHEN Generator voltage has risen to > 234 volts AND is NOT increasing, THEN release the FIELD FLASH pushbutton.

Standard: Simulates FIELD FLASH pushbutton released.

CUE: Generator voltage has risen to 250 volts AND is steady.

CUE: Component is in desired condition.

Comment:

Page 7 of 13

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION S-1A, step 5.3.4.4

/, Performance Step: 21 Rotate the VOLTAGE ADJUST potentiometer clockwise UNTIL voltage is 260.

Standard: Rotates the VOLTAGE ADJUST potentiometer clockwise UNTIL voltage is 260.

CUE: Generator voltage has risen slowly to 260 volts.

Comment:

S-1A, stelp 5.3.5 Performance Step: 22 Verify FIELD CURRENT is >1.2 amps AND c4.8 amps as read on the FlEiLD CURRENT METER.

Standard: Identifies FIELD CURRENT METER.

CUE: FIELD CURRENT is as read.

Comment:

S-1A, step 5.3.6 Performance step: 23 Verify FIELD CURRENT alarm has cleared. (Alarm LED is located or the FIELD CURRENT METER)

Standard: Identifies alarm LED on the FIELD CURRENT METER is out.

CUE: Alarm LED on the FIELD CURRENT METER is out.

Comment:

S-1A, step 5.3.7 Performgnce Step: 24 Place ALARM BYPASS switch in the "ACTIVE position.

Standard: Identifies ALARM BYPASS switch and simulates placing in "ACTIVE".

CUE: Component is in desired position.

Comment:

Page 8 of 13

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATlON S-1 A, step 5.3.8 Performance Step: 25 Verify MCB annunciator C-21 (Rod Control MG Set Trouble) is extinguished.

Standard: Contacts control room on status of C-21.

CUE: C-21, (Rod Control MG Set Trouble) is extinguished.

Comment:

S-1A, step 5.3.9

/, Performance Step: 26 Rotate the synchronize switch to ON (on the MG set being started) AND allow a few seconds for the synchronizer to warm UP-Standard: Rotates the 1A synchronize switch to ON (AND allows a few seconds for the synchronizer to warm up.

CUE: Component is in desired position.

Comment:

S-1 A, step 5.3.10.1 4 Performance step: 27 Observe the Synchroscope (SynKRDMGAB) for indication when the two generators are in sync and trip the on-coming M/G Set Motor Breaker by rotating the circuit breaker control handle to the TRIP POSITION just after the Synchronizing Point (approximately 3 minutes after 12).

Standard: Observes the Synchroscope for indication when the two generators are in sync and trips the 1A M/G Set Motor Brealker by rotating the circuit breaker control handle to the TRIP POSllnONjust after the Synchronizing Point (approximately 3 minutes after 12).

CUE: Component is in desired position.

CUE: Synchroscope indicates the two generators are in parallel.

Comment:

fage 9 of 13

Appendix C Jab Performance Measure Form ES-C-1 PERFORMANCE INFORMATION S-1A, step 5.3.10.2 (End Alternate Path)

Performance Step: 28 Should the Generator fail to parallel within 30 seconds, THEN return the synchronize switch to OFF, AND proceed with steps 5.3.1 through 5.3.10again. N/A if generator paralleled.

Standard: Synchronize switch in on.

Step N/Ad.

CUE: Synchroscope indicates the two generators are in parallel.

Comment:

S-1A, step 5.3.1 0.3 Performance Step: 29 Turn the Synchronize switch to the OFF position.

Standard: Synchronize switch in the OFF position.

CUE: Component is in desired Iposition.

Comment:

S-1A, step 5.3.1 1 Performance step: 30 Verify ROII DRIVE M-G SET 1A (MCB center section) red status light is lit.

Standard: Calls Contirol Room to verify ROD DRIVE M-G SET 1A red status light is lit.

CUE: From Control Room, ROD DRIVE M-G SET 1A red status light is lit.

Comment:

S-lA, step 5.3.12 Performance step: 31 Verify ROC) DRIVE M-G SET 16 (MCB center section) red status light is lit.

Standard: Calls Control Room to verify ROD DRIVE M-G SET 1B red status light is lit.

CUE: From Control Room, ROD DRIVE M-G SET 1B red status light is lit.

Comment:

F'age 10 of 13

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION S-1A, step 5.3.13

/, Performance Step: 32 Adjust MG1A and MG1B voltages to minimize MG CIRCULATING CURRENT (indicated on CIRCULATING CURRENT METER) with MG OUTPUT AC VOLTAGE close to 260 volts (between 250 and 270 volts) and FIELD CURRENT

~ 1 . amps 2 and <4.8 amps on both MGs.

Standard: MG OUTPUT AC VOLTAGE close to 260 volts (between 250 and 270 volts) and FIELD CURRENT >1.2 amps and c4.8 amps on both MGs.

Records Ckulating Current.

CUE: CIRCULATING CURRENT is as read.

Comment:

S-1A, step 5.3.14 Performance Step: 33 Verify MCB annunciator C-21 (Rod Control MG Set Trouble) is extinguished.

Standard: Contacts control room on status of C-21.

CUE: C-21, (Rod Control MG Set Trouble) is extinguished.

Comment:

Terminating Cue: Evaluation on this JPM is complete.

STOP TIME: TIME CRITICAL STOP TIME:

Page 11 of 13

Appendix C Job Performance Measure Form ES-C-1 VERIFICATION OF COMPLETION Job Performance Measure No.: 2008 NRC JPM I Examinees Name:

Date Performed:

Facility Evaluator:

Number of Attempts:

Time to Complete:

Question Documentation:

Question:

Response

Result: SAT UNSAT Examiners Signature: Date:

Page 12 of 13

Appendix C Job Performance Measure Form ES-C-1 JPM CUE SHEET Initial Conditions: 0 You are an extra RO.

0 Preparationsfor startup of Rod Control System are under way.

0 The " 1 B MG set is running.

Initiating Cue: The Shift Manager directs you to startup and parallel the 1A Rod Drive MG Set per S-1A section 5.3.

Simulate all activities - DO NOT MANIPULATE ANY EQUIPMENT.

Page 130f 13

Appendix C Job Performance Measure Form ES-C-1 Worksheet Facility: Ginna Task No.: 062-029-05-04E TasWJPM

Title:

Align Fire Water Sysitem to Fill the JPM No.: 2008 NRC JPM J CSTs Using Condensate Transfer System WA

Reference:

061 K4.01 4.1 / 4.2 Examinee: NRC Examiner:

Facility Evaluator: Date:

Method of testina:

Simulated Performance: X Actual Performance:

Classroom Simulator Plant X Applicability: RO/SRO SUBMllTED BY: Ted Coe DATE: 6/30/08 Developer REVIEWED BY: Art Vest DATE: 6/30/08 Training Technical Reviewer REVIEWED BY: Don Dettman DATE: 6/30/08 Operations Technical Reviewer APPROVED BY: John Blrown DATE: 6/30/08 Training Management Page 1 of 7

Appendix C Job Performance Measure Form ES-C-1 Worksheet Task Standard: Line up to fill CST in accordance with ER-AFW.l section 4.3.1 and all critical tasks evahated as satisfactory.

Required Materials: Proper Noise Protection, Hard Hat, Safety Glasses, Safety Shoes, Gloves. (2)Spanner wrenches and Fire Hose.

General

References:

ER-AFW.1,: ALTERNATE WATER SUPPLY TO THE A M I PUMPS, Rev. 03001 Handouts: ER-AFW.1,: ALTERNATE WATER SUPPLY TO THE AFW PUMPS, Rev. 03001 Time Critical Task: Yes Validation Time: 11 minutes Alternate Path: NO Instructor Notes: Ensure Proper Noise Protection, Hard Hat, Safety Glasses, Safety Shoes, Gloves are worn as required.

Ensure a marked up copy of ER-AFW.l , ALTERNATE WATER SUPPLY TO THE A R N PUIMPS, Rev.03001 is ready to give to the operator during the Initiating Cue.

READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues, When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.

Initial Conditions: You are an extra RO.

0 The Plant has experienced a loss of Offsite Power.

0 CST inventory is depleted with level < 5 ft.

0 The AFW pumps are providing S/G inventory.

Initiating Cue: The Shift Manager directs you to align the Fire Water System to fill the CSTs using the Condensate Transfer System in accordance with ER-AFW.l section 4.3.1.

Simulate all activities - DO NOT MANIPULATE ANY EQUIPMENT.

This is a time critical JPM.

CUE: Hand the Operator a marked up copy of ER-AFW.l, Rev. 03001.

'>age 2 of 7

Appendix C Jc b Performance Measure Form ES-C-1 PERFORMANCE INFORMATION START TIME:

d = CRITICAL STEP ER-AFW:I ,step 4.3.1.1 Performance Step: 1 Place Howell Level Controller LC-107 in manual at 50%.

Standard: Simulates requesting Control Room place Hotwell Level Controller in manual and 50% output.

CUE: Acknowledge request and inform the examinee that the Hotwell Level controller is in manual at 50% output.

Comment:

ER-AFW.ll, step 4.3.1.2

/, Performance step: 2 Close or verify closed the following valves:

CNDST XFER PUMP DISCH ISOL TO HOSE TAPS, valve 4049C 0 CNDST XFER PUMP DISCH SAMPLE, valve 4049A 0 CNDST XFER PUMP DISCH TO MIX BED POLISHER DIS, valve 4050 0 CNDST XFER PUMP DISCH TO CST, valve 9509C 0 CNDST XFER PUMP SUCTION ISOL FROM HOWELL, valve 4046 (in east condenser pit)

CNDST XFER PUMP SUCTION FROM A&B CST, valve 4047 0 OUTSIDE CST FILL ISOL, valve 9509D Standard: Finds, iderltifies and closes or verifies closed the following valves:

1. CNDST XFER PUMP DISCH ISOL TO HOSE TAPS, valve 4049C
2. CNiDST XFER PUMP DISCH SAMPLE, valve 4049A
3. CNIXT XFER PUMP DISCH TO MIX BED POLISHER DE;, valve 4050
4. CNIXT XFER PUMP DISCH TO CST, valve 9509C
5. CNBST XFER PUMP SUCTION ISOL FROM HOWELL, valve 4046 (in east condenser pit)
6. CNIXT XFER PUMP SUCTION FROM A&B CST, valve 4047
7. OUTSIDE CST FILL ISOL, valve 95090 CUE: Component is in desired position. (for each valve operated)

Comment:

Page 3 of 7

Appendix C Jl3b Performance Measure Form ES-C-1 PERFORMANCE INFORMATION ER-AFW,,l,step 4.3.1.3 Performance Step: 3 Obtain tho spanner wrenches (on handrail by Cond Transfer Pump).

Standard: Locates spanner wrenches.

CUE: You have two spanner wrenches.

Comment:

ER-AFW.l, step 4.3.1.4 Performance step: 4 Isolate/rernove and cap all temporary hoses from the connections at CNDST XFER PUMP DISCH ISOL TO HOSE TAPS, valve 4049C.

Standard: Finds and simulates removing and capping hoses connected at valve 404!E.

CUE: All hoses are disconnected and capped.

Comment:

ER-AFW.l, step 4.3.1.5

/,, Performance Step: 5 Run the hose from fire water hose reel #2 (located by Battery Room door) AND connect at CNDST XFER PUMP DISCH ISOL TO HOSE TAPS, valve 4049C.

Standard: Simulates running hose from hose reel #2to valve 4049C.

CUE: The hose is connected between hose reel #2 and valve 4049C.

Comment:

ER-AFW.1, step 4.3.1.6 NOTE Performance step: 6 NOTE: The! Diesel Fire Pump should auto start while performing the following.

Standard: Placekeeps and reads note. May inform control room.

CUE: Acknowledge report, if made.

Comment:

fage 4 of 7

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION ER-AFW.l, step 4.3.1.6 4 Performance Step: 7 Slowly open the following valves:

CNDST XFER PUMP RECIRC, valve 4048 CFJDST XFER PUMP DISCH ISOL TO HOSE TAPS, valve 40496 0 TLlRBlNE BLDG HOSE REEL #2 ISOL, valve 5178 Standard: Finds, identifies and slowly opens the following valves:

1. CNDST XFER PUMP RECIRC, valve 4048
2. CNDST XFER PUMP DlSCH ISOL TO HOSE TAPS, valve 4049C
3. TURBINE BLDG HOSE REEL #2 ISOL, valve 5178 CUE: Component is in desired position. (for each valve operated)

Comment: Record TIME CRITICAL STOP TIME, must be less than 12 minutes firom start time.

ER-AFW.1, step 4.3.1.7 Performance Step: 8 Fill CSTS 21s required.

Standard: Monitors fillling CST.

CUE: No further action requiredl.

Comment:

Terminating Cue: Evaluatiori on this JPM is complete.

STOP TIME: TIME CRITICAL STOP TIME:

Page 5 of 7

Appendix C Job Performance Measure Form ES-C-1 VERIF:ICATION OF COMPLETION Job Performance Measure No.: 2008 IVRC JPM J Examinees Name:

Date Performed:

Facility Evaluator:

Number of Attempts:

Time to Complete:

Question Documentation:

Question:

Response

Result: SAT -- UNSAT Examiners Signature: Date:

Page 6 of 7

Appendix C Job Performance Measure Form ES-C-1 JPM CUE SHEET Initial Conditions: 0 You are an extra RO.

0 The Plant has experienced a loss of Offsite Power 0 CST inventoiy is depleted with level < 5 ft.

0 The AFW pumps are providing S/G inventory.

Initiating Cue: The Shift Manager directs you to align the Fire Water System to fill the CSTs using the Condensate Transfer System in accordance with ER-A m . 1 section 4.,3.1.

Simulate all activities - DO NOT MANIPULATE ANY EQUIPMENT.

This is a time critical JPM.

Page 7 of 7

Appendix C Jc b Performance Measure Form ES-C-1 Worksheet Facility: Ginna Task No.: 062-030-05-04A TasWJPM

Title:

Trip of Failed AC Emergency UV JPM No.: 2008 NRC JPM K Relay WA

Reference:

APE 077 AA1.05 3.9/4.0 Examinee: NRC Examiner:

Facility Evaluator: Date:

Method of testina:

Simulated Performance: X Actual Performance:

Classroom Simulator Plant X Applicability: RO/SRO SUBMITTED BY: Ted Coe DATE: 6/30/08 Developer REVIEWED BY: Art Vest DATE: 6/30/08 Training Technical Reviewer REVIEWED BY: Don Dettman DATE: 6/30/08 Operations Technical Reviewer APPROVED BY: John Brown DATE: 6/30/08 Training Management Page 1 of 6

Appendix C Job Performance Measure Form ES-C-1 Worksheet Task Standard: Perform a manual trip of a relay for undervoltage protection on Bus 14 and all critical tasks evaluated as satisfactory.

Required Materials: Proper Noise Protection, Hard Hat, Safety Glasses, Safety Shoes, Gloves.

Undervoltage cabinet key #25 (the use of this key will be simulated).

General

References:

ER-UV.l, TRIP OF FAILED AC EMERGENCY UV RELAY, Rev. 5 Handouts: ER-UV.1, TRIP OF FAILED AC EMERGENCY UV RELAY, Rev. 5 Time Critical Task: NO Validation Time: 10 minutes Alternate Path: NO Instructor Notes: Ensure Proper Noise Protection, Hard Hat, Safety Glasses, Safety Shoes, Gloves are worn as required.

Ensure a marked up copy of ER-UV.l, TRIP OF FAILED AC EMERGENCY UV RELAY, Rev. 5 is ready to give to the operator during the Initiating Cue and undervoltage cabinet key #25.

READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.

Initial Conditions: 0 You are an extra RO.

0 The control room has received L-14, Bus 14 Undervoltage Safeguards annunciator.

0 Procedure ER-UV.1, TRIP OF FAILED AC EMERGENCY UV RELAY is being performed and the control room staff is at step 4.2.2.

Initiating Cue: The CRS directs you to perform a manual trip of Loss of Voltage 27 D/B relay for Bus 14 por Attachment BUS 14, PART B of ER-UV.l.

Simulate all activities - DO NOT MANIPULATE ANY EQUIPMENT, Bus 14, Attachment BUS 14, PART A of ER-UV.l has NOT been performed.

CUE: Hand the Operator a marked up copy of ER-UV.l, TRIP OF FAILED AC EMERGENCY UV RELAY, Rev. 5 and undervoltage cabinet key #25.

Page 2 of 6

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION START TIME:

4 = CRITICAL STEP ER-UV.l, Att. Bus 14, part 8, step 6.1 Performance Step: 1 Verify Part A has NOT been performed.

Standard: Verifies with Part A has not been performed, given in initiating cue, may call control room or may check Part A for Bus 14.

CUE: If requested, report as CFIS Part A for Bus 14, has not been performed.

If local indications are checked: Component is in as found position.

Comment:

ER-UV.l , Att. Bus 14, part 6, step 6.2 4 Performance Step: 2 Place the TEST ENABLE key switch (S20)on the BUS14 Auxiliary Flelay Rack (bottom left hand corner) to the TEST position. (Key cannot be removed w hen in TEST position.)

Standard: Locates kay switch and simulates inserting key and rotating key to TEST position.

CUE: Component is in desired position.

Comment:

Dage3 of 6

Appendix C Job Performance Measure Form ES-C-1 PERFORMANCE INFORMATION ER-UV.l, Att. Bus 14, part B, step 8.3

/, Performance Step: 3 Place each individual Auxiliary Relay toggle switch to the TRIP position and verify that each Yellow UV light energizes or remains energized. (Located on the Auxiliary Relay Rack) 0 Relay BX1/14 Toggle sw itch to TRIP Yellow UV Light LIT MCB Annunciator L-14 ENERGIZED 0 Relay BX2/14 Toggle switch to TRIP Yellow UV Light LIT 0 Relay BX3/14 Toggle switch to TRIP Yellow UV Light LIT 0 Relay BX4/14 Toggle switch to TRIP Yellow UV Light LIT 0 Remlay BX5/14 Toggle switch to TRIP Yellow UV Light LIT Relay BX6/14 Toggle switch to TRIP Yellow UV Light LIT Standard: Locates each toggle switch listed and simulates toggling switch to TRIP. Verifies UV light lit for each toggle switch operated.

0 Relay BX1/14 Toggle sw itch in TRIP Yellow UV Light LIT MCB Annunciator L-14 ENERGIZED 0 Relay BX2/14 Toggle switch in TRIP Yellow UV Light LIT 0 Relay BX3/14 Toggle switch in TRIP Yellow UV Light LIT Relay BX4/14 Toggle switch in TRIP Yellow UV Light LIT 0 Relay BX5/14 Toggle switch in TRIP Yellow UV Light LIT Relay BX6/14 Toggle switch in TRIP Yellow UV Light LIT CUE: Component is in desired position. / Light is lit. / MCB Ann. Is energized.

Comment:

ER-UV.l, Att. Bus 14, part B, step 8.4 Performance Step: 4 Return to :;tep 4.2.3.

Standard: Contacts the control room to continue on at step 4.2.3.

CUE: Acknowledge report.

Comment:

Terminating Cue: Evaluation on this JPM is complete.

STOP TIME: TIME CRITICAL STOP TIME:

Page 4 of 6

Appendix C Jot) Performance Measure Form ES-C-1 VERIFICATION OF COMPLETION Job Performance Measure No.: 2008 NIRC JPM K Examinees Name:

Date Performed:

Facility Evaluator:

Number of Attempts:

Time to Complete:

Question Documentation:

Question:

Response

Result: SAT UNSAT Examiners Signature: Date:

Page 5 of 6

Appendix C Job Performance Measure Form ES-C-1 JPM CUE SHEET Initial Conditions: You are an extra RO.

The contr3l room has received L-14, Bus 14 Undervoltage Safeguards annunciator.

0 Procedurc ER-UV.1, TRIP OF FAILED AC EMERGENCY UV RELAY is being performed and the control room staff is at step 4.2.2.

Initiating Cue: The CRS directs you to perform a manual trip of Loss of Voltage 27 D/B relay for Bus 14 per Attachment BUS 14, PART B of ER-UV.1.

Simulate all activities - DO NOT MANIPULATE ANY EQUIPMENT.

Bus 14, Attachment BUS 14, PART A of ER-UV.1 has U T been performed.

Page 6 of 6