Ginna LC 15-1 NRC Written Exam Seating Chart uz.
Ut RS Ri
Applicant Name:
I:z_
Applicant level:
RO:O I SR():~
RO Question '#: 2 I
SRO Question #:
Question and Comment:
A.SS...J rnE
!liAI "Utv T A c.TLJ/t7E 7
- -1 fLc. i£ -ro S...L NO
~
(1-.J.
f1,J~(;.) (1.
QJcST10..J l..t I Tr(
I iJ f ofl(n ATJotJ PP-o v (DEi>
Response
Withheld additional guidance. !11Structed appHcants do the best they ran. based on the
~
information provkled.
Did not withhold additional guidance. Provided the foltowing response (enter verbatim).
D Changes and Cl.arificatlons Made To Examination:
Identified on.. mite boord D
Verbally carled to applicants attention r-1 NO changes made to key D
Pen and ink chanqe made 'lo kev _ ff reou ired I l Proctor (Print): *nAv10
... (l..--
. c1~E.i Proctor (Signature): {}
~ **~71\\
, 'O.i1t -.7-*er. !L.
I Date: ::; /_;z "-!) 24> I 7
Appli.cant Name:
UL Applirant Level:
RO:O I SRO:~
RO Question #: l '-f I SRO Question#:
Question r:Jnd Comment:
ot2-lt1 r1rJ t} /\\C 7 APe-c C.O,.J TV-0 L (Loos
(.-J liJ '(()
1HEY AIL /,j
,J ofllYlAL r OS l Tlo.,J for~ Gl v£,J co,J l) 1Tlc#5 Respom.e:
Withheld additional guidance. lnstructed appHcants do the best they can. based on the
~
information provided.
Did not vtithhold addvtionar guidance.. Provided the foltowing response (enter verbatim).
D Changes and Clarifications Made To Examination:
Edentified on white board n
\\lerb.alry caMed to applicants attention r-*1 NO changes made to key n
Pen and ink chanqe made to kev. if reauired i I Proctor {Print):
bAiJ10 Eo_,c,EpS Proctor (Signature):
J},,M#&~#
I Date: ->& tfl ut 7
Appltca nt Name:
I7 Appli;cant level:
RO:O I SRC:t~
RO Question #: 34>
I SRO Question ti-:
Question and Comment:
CA,.hJOt l~~st){)'L 1HE c).Jc_s, T1 cvJ i,J 1n-I D0'( 3Er..J ~ b. 1<.1E,-v1 A f="<--J
~LOJ f-./>t 1£S..
r4M f LoiJ IS
,~s --
f1 ~
c J(, c: c:.~ Fo1t 17-12 <'= 1v-E,,.l PLA~I (c,,J}); I I.o,J 5
Response
Withheld additional guidance. lnstructed applicants do the bes,t they can. based on the
){I information provtded.
Did not withhold additional gutdance. Provided the f oliowing response (enter verbatim).
n Changes and Ctarificatfons Made To E:xi.minaUon:
Identified on white board n
Verbally called to applic:ants attention 1-1 NO changes made to key n
Pen and ink chanqe made to kev. rr required r I Proctor (Pri:nt):
vA //1 D cCi~c(z::(
Proctor {Stgnature): OrL~/~~~
I Date: 3/zr{ / X!Jt7 v
Applicant Name:
r7-
~.:.
I SRO:~
Applicant Level:
RO:O RO Question #:
I SRO Question #: '& 7 Question and Comment:
NO eo11..s2..E c...T A.J s. ui C17-AS f o0 uJDi..;Z... °b c.o~C A,J (Lc..p f\\.vO c_,.rTBZ-A P-P-c.s.z f+.J ()
{/1...;q,J.. I T I o.J To
£~q -rHE,.J C.S,- <]:, *. /.
f-l tJ <
I 6'L 1;.J tfrH YoJ fc,c'-
i 5 -n+6
(...,Q f-JL-6 c,( f jJ.,{) C'C<O U f'-l c (,,,0 w f' fl 11i I
. )VJ
&Asc£0 o,J
(.;,¥I 116.rJ p t.,./.J/'11'"
GO JJ 'i) 1rrofl.5..
c.fl L. t...ci:>
c.H-1 i:;F x A h1 1.rl' c:-y1... *rD I r-J (.o fl--rn 1f+AI A CHM GE
[,/ t L...l-p r- 0 P> ft/) t.r'I lJ cc.cJf-Af-tt"il Xf'rn f!..£111 r;tJ.
Response
Vlithheld add!tional guidance. Instructed appHcrm'!.s do the besl they can. based on the information 1xo1.*ided.
LJ Did not withhohj addftion.at guidance. Provided the following response {enter verbatim).
0 Changes and Clarifications Made To Examination:
tde rrtified on white board n
Verbally called to apptic.a11ts attention r-1 NO changes made to key n
Pen and ink chanqe made to kev. if required i I Proctor {Prtntr !:>AV; D l C~fL(
Proctor (Signature;: Do vJ;f &J~r l Date: 36{ /u111
Instructor:
Total Possible:
75 Exam Name:
Exam Date:
\\(0?
Wednesday, March 29, 2017
()~I-I Highest Score:
70 - 93.33%
Lowest Score:
58 - 77.33%
Correct answers are shown in bold and italics Blanks Ql A (1, 16.7%)
B (5, 83.3%) c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q2 A (0, 0.0%)
B (0, 0.0%)
C (6, 100.0%) D (0, 0.0%)
E (0, 0.0%)
Q3 A (3, 50.00/o)
B (0, 0.0%)
c (0, 0.0%)
D (3, 50.0%)
E (0, 0.0%)
Q4 A (6, 100.0%) B (0, 0.0%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q5 A (0, 0.0%)
B (0, 0.0%)
C (6, 100.0%) D (0, 0.0%)
E (0, 0.0%)
Q6 A (0, 0.0%)
B (0, 0.0%)
c (0, 0.0%)
D (6, 100.0%) E (0, 0.0%)
Q7 A (5, 83.3%)
B (0, 0.0%)
c (1, 16.7%)
D (0, 0.0%)
E (0, 0.0%)
QB A (2, 33.3%)
B (0, 0.0%)
c (4, 66.70/o)
D (0, 0.0%)
E (0, 0.0%)
Q9 A {O, 0.0%)
B (0, 0.0%)
C {O, 0.0%)
D (6, 100.0%) E (O, 0.0%)
Q 10 A (6, 100.00/o) B (0, 0.0%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 11 A (0, 0.0%)
B (6, 100.0%) C (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 12 A (2, 33.3%)
B (0, 0.0%)
c (4, 66.70/o)
D {O, 0.0%)
E (0, 0.0%)
Q 13 A (6, 100.0%) B (0, 0.0%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 14 A (0, 0.0%)
B (0, 0.0%)
C (6, 100.00/o) D (0, 0.0%)
E (0, 0.0%)
Q 15 A (0, 0.0%)
B (O, 0.0%)
c (0, 0.0%)
D (6, 100.0%) E (0, 0.0%)
Q 16 A (6, 100.00/o) B (0, 0.0%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 17 A (1, 16.7%)
B (0, 0.0%)
c (5, 83.30/o)
D (0, 0.0%)
E (0, 0.0%)
Q 18 A (1, 16. 7%)
B (2, 33.3%) c (3, 50.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 19 A (0, 0.0%)
B (0, 0.0%)
c (0, 0.0%)
D (6, 100.00/o) E (0, 0.0%)
Q 20 A (6, 100.00/o) B (0, 0.0%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 21 A (0, 0.0%)
B (5, 83.3%) c (0, 0.0%)
D (1, 16.7%)
E (0, 0.0%)
Q 22 A (4, 66.7%)
B (0, 0.0%)
c (2, 33.30/o)
D (0, 0.0%)
E (0, 0.0%)
Q 23 A (0, 0.0%)
B (0, 0.0%)
c (0, 0.0%)
D (6, 100.0%) E (0, 0.0%)
Q 24 A (6, 100.00/o) B (0, 0.0%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 25 A (0, 0.0%)
B (0, 0.0%)
c (0, 0.0%)
D (6, 100.0%) E (0, 0.0%)
Q 26 A (0, 0.0%)
B (6, 100.00/o) C (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 27 A (6, 100.0%) B (0, 0.0%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Report run date: 3/29/2017 8:58 AM Class Average:
Class Median:
KR20:
Multiples Point Correct Biserial 0.23 5, 83.3%
0.00 6, 100.0%
-0.48 3, 50.0%
0.00 6, 100.0%
0.00 6, 100.0%
0.00 6, 100.0%
0.23 5, 83.3%
0.69 4, 66.7%
0.00 6, 100.0%
0.00 6, 100.0%
0.00 6, 100.0%
0.06 4, 66.7%
0.00 6, 100.0%
0.00 6, 100.0%
0.00 6, 100.0%
0.00 6, 100.0%
0.57 5, 83.3%
0.79 2, 33.3%
0.00 6, 100.00/o 0.00 5, 100.0%
0.23 5, 83.3%
-0.27 2, 33.3%
0.00 5, 100.0%
0.00 6, 100.0%
0.00 6, 100.0%
0.00 6, 100.0%
0.00 6, 100.0%
64.00 - 85.33%
61.0 - 81.33%
0.679 Percent Incorrect j,
16.7%
I 0.0%
\\'.'.":)'.~ -'.-~010%
0.0%
0.0%
0.0%
16.7%
33.3%
0.0%
0.0%
0.0%
<o 33.3%
0.0%
0.0%
0.0%
0.0%
16.7%
>. ;::j**' 66!7.% ;.
0.0%
0.0%
I 16.7%
- ,
- ;'! 66.17%'
0.0%
0.0%
0.0%
0.0%
0.0%
Page 1
Instructor:
Total Possible:
75 Class Average:
64.00 - 85.33%
Exam Name:
Highest Score:
70 - 93.33%
Class Median:
61.0 - 81.33%
Exam Date:
Wednesday, March 29, 2017 Lowest Score:
58 - 77.33%
KR20:
0.679 Correct answers are shown in bold and italics Blanks Multiples Point Correct Percent Incorrect Biserial Q 28 A (1, 16.7%)
B (0, 0.0%)
c (5, 83.3%)
D (0, 0.0%)
E (0, 0.0%)
0.23 5, 83.3%
I 16.7%
Q 29 A (0, 0.0%)
B (5, 83.3%) c (0, 0.0%)
D (1, 16.7%)
E (0, 0.0%)
0.57 5, 83.3%
16.7%
Q 30 A (1, 16.7%)
B (0, 0.0%)
c (5, 83.3%)
D (0, 0.0%)
E (0, 0.0%)
0.57 5, 83.3%
16.7%
Q 31 A (0, 0.0%)
B (0, 0.0%)
c (0, 0.0%)
D (6, 100.0o/o) E (0, 0.0%)
0.00 6, 100.0%
0.0%
Q 32 A (6, 100.0o/o) B (0, 0.0%)
c (0, 0.0%)
D (0, 0.0%)
E (O, 0.0%)
0.00 6, 100.0%
0.0%
Q 33 A (0, 0.0%)
B (0, 0.0%)
c (0, 0.0%)
D (6, 100.0o/o) E (0, 0.0%)
0.00 6, 100.0%
0.0%
Q 34 A (1, 16.7%)
B (0, 0.0%)
c (5, 83.3%)
D (0, 0.0%)
E (0, 0.0%)
0.57 5, 83.3%
16.7%
Q 35 A (0, 0.0%)
B (6, 100.0%) C (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
0.00 6, 100.0%
0.0%
Q 36 A (0, 0.0%)
B (1, 16.7%)
c (1, 16.7%)
D (4, 66.7%)
E (O, 0.0%)
0.34 1, 16.7%
83.3%
Q 37 A (0, 0.0%)
B (0, 0.0%)
c (0, 0.0%)
D (6, 100.0o/o) E (0, 0.0%)
0.00 6, 100.0%
0.0%
Q 38 A (0, 0.0%)
B (0, 0.0%)
C (6, 100.0o/o) D (0, 0.0%)
E (0, 0.0%)
0.00 6, 100.0%
0.0%
Q 39 A (6, 100.0o/o) B (0, 0.0%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
0.00 6, 100.0%
0.0%
Q 40 A (0, 0.0%)
B (3, 50.0o/o) c (1, 16.7%)
D (2, 33.3%)
E (0, 0.0%)
0.92 3, 50.0%
'. :50.0%
Q 41 A (5, 83.3%)
B (1, 16.7%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
0.57 5, 83.3%
16.7%
Q 42 A (1, 16.7%)
B (5, 83.3%) c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
-0.49 5, 83.3%
16.7%
Q 43 A (0, 0.0%)
B (0, 0.0%)
c (0, 0.0%)
D (6, 100.0o/o) E (0, 0.0%)
0.00 6, 100.0%
0.0%
Q 44 A (0, 0.0%)
B (5, 83.3%) c (1, 16.7%)
D (0, 0.0%)
E (0, 0.0%)
0.23 5, 83.3%
16.7%
Q 45 A (6, 100.0o/o) B (0, 0.0%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
0.00 6, 100.0%
0.0%
Q 46 A (O, 0.0%)
B (0, 0.0%)
C(5, 83.3%)
D (1, 16.7%)
E (0, 0.0%)
0.57 5, 83.3%
16.7%
Q 47 A (0, 0.0%)
B (0, 0.0%)
c (4, 66.7%)
D (2, 33.3%)
E (0, 0.0%)
0.69 4, 66.7%
- 33.3%
Q 48 A (0, 0.0%)
B (0, 0.0%)
c (0, 0.0%)
D (6, 100.0o/o) E (0, 0.0%)
0.00 6, 100.0%
0.0%
Q 49 A (0, 0.0%)
B (6, 100.0%) C (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
0.00 6, 100.0%
0.0%
Q 50 A (1, 16.7%)
B (5, 83.3%) c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
0.57 5, 83.3%
16.7%
Q 51 A (6, 100.0o/o) B (0, 0.0%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
0.00 6, 100.0%
0.0%
Q 52 A (3, 50.0%)
B (2, 33.3%) c (1, 16.7%)
D (0, 0.0%)
E (0, 0.0%)
-0.79 2, 33.3%
- 66."Z%'
Q 53 A (2, 33.3%)
B (0, 0.0%)
c (3, 50.0%)
D (1, 16.7%)
E (0, 0.0%)
-0.03 2, 33.3%
- >*,. 66.7%
Q 54 A (1, 16.7%)
B (0, 0.0%)
c (4, 66.7%)
D (1, 16.7%)
E (0, 0.0%)
-0.19 4, 66.7%
33.3%
Report run date: 3/29/2017 8:58 AM Page 2
Instructor:
Total Possible:
75 Class Average:
64.00 - 85.33%
Exam Name:
Highest Score:
70 - 93.33%
Class Median:
61.0 - 81.33%
Exam Date:
Wednesday, March 29, 2017 Lowest Score:
58 - 77.33%
KR20:
0.679 Correct answers are shown in bold and italics Blanks Multiples Point Correct Percent Incorrect Biserial Q 55 A (2, 33.3%)
B (0, 0.0%)
c (0, 0.0%)
D(4, 66.7%)
E (0, 0.0%)
-0.03 4, 66.7%
I
- 33.3%
Q 56 A (0, 0.0%)
8 (6, 100.0%) c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
0.00 6, 100.0%
I 0.0%
Q 57 A (0, 0.0%)
B (0, 0.0%)
c (1, 16.7%)
D (5, 83.3%)
E (0, 0.0%)
0.23 5, 83.3%
I,, "
16.7%
Q 58 A (0, 0.0%)
B (0, 0.0%)
C (6, 100.0%) D (0, 0.0%)
E (0, 0.0%)
0.00 6, 100.0%
I 0.0%
Q 59 A (1, 16.7%)
8 (2, 33.3%) c (0, 0.0%)
D (3, 50.0%)
E (0, 0.0%)
0.14 2, 33.3%
- 3,'i'
~6.7%
Q 60 A (0, 0.0%)
B (0, 0.0%)
c (0, 0.0%)
D (6, 100.0%) E (0, 0.0%)
0.00 6, 100.0%
0.0%
Q 61 A (0, 0.0%)
B (0, 0.0%)
C (6, 100.0%) D (0, 0.0%)
E (0, 0.0%)
0.00 6, 100.0%
0.0%
Q 62 A (0, 0.0%)
B (0, 0.0%)
c (0, 0.0%)
D (6, 100.0%) E (0, 0.0%)
0.00 6, 100.0%
0.0%
Q 63 A (0, 0.0%)
8 (3, 50.0%) c (1, 16.7%)
D (2, 33.3%)
E (0, 0.0%)
0.28 3, 50.0%
I" :..
,~.,,.:,so.0%
Q 64 A (0, 0.0%)
B (0, 0.0%)
c (0, 0.0%)
D (6, 100.0%) E (0, 0.0%)
0.00 6, 100.0%
I 0.0%
Q 65 A (6, 100.0%) B (0, 0.0%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
0.00 6, 100.0%
I 0.0%
Q 66 A (0, 0.0%)
B (1, 16.7%)
c (1, 16.7%)
D (4, 66.7%)
E (O, 0.0%)
0.23 4, 66.7%
I
': 33.3%
Q 67 A (0, 0.0%)
B (0, 0.0%)
C (6, 100.0%) D (0, 0.0%)
E (0, 0.0%)
0.00 6, 100.0%
I 0.0%
Q 68 A (0, 0.0%)
8 (5, 83.3%) c (0, 0.0%)
D (1, 16.7%)
E (0, 0.0%)
0.23 5, 83.3%
I,, '**
16.7%
Q 69 A (6, 100.0%) B (0, 0.0%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
0.00 6, 100.0%
I 0.0%
Q 70 A (1, 16.7%)
B (0, 0.0%)
c (1, 16.7%)
D (4, 66.7%)
E (0, 0.0%)
0.41 4, 66.7%
I***.-*: 33.3%
Q 71 A (1, 16.7%)
8 (5, 83.3%) c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
0.23 5, 83.3%
1**yi 16.7%
Q 72 A (1, 16.7%)
8 (5, 83.3%) c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
-0.49 5, 83.3%
I 16.7%
Q 73 A (0, 0.0%)
B (0, 0.0%)
C (6, 100.0%) D (0, 0.0%)
E (0, 0.0%)
0.00 6, 100.0%
I 0.0%
Q 74 A (6, 100.0%) B (0, 0.0%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
0.00 6, 100.0%
I 0.0%
Q 75 A (0, 0.0%)
8 (5, 83.3%) c (1, 16.7%)
D (0, 0.0%)
E (0, 0.0%)
0.23 5, 83.3%
I 16.7%
Report run date: 3/29/2017 8:58 AM Page 3
Instructor:
5~
Total Possible:
100 Exam Name:
Exam Date:
Wednesday, March 29, 2017 oVL-'f Highest Score:
91 - 91.00%
Lowest Score:
79 - 79. 00%
Correct answers are shown in bold and italics Blanks Ql A (0, 0.0%)
B (9, 100.0o/o) C (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q2 A (1, 11.1%)
B (0, 0.0%)
C(B, 88.9%)
D (O, 0.0%)
E (0, 0.0%)
Q3 A (7, 77.8%)
B (0, 0.0%)
c (0, 0.0%)
D (2, 22.2%)
E (0, 0.0%)
Q4 A (9, 100.0o/o) B (0, 0.0%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
QS A (0, 0.0%)
B (0, 0.0%)
C (9, 100.0o/o) D (0, 0.0%)
E (0, 0.0%)
Q6 A (0, 0.0%)
B (0, 0.0%)
c (0, 0.0%)
D (9, 100.0o/o} E (0, 0.0%)
Q7 A (9, 100.0o/o) B (0, 0.0%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
QB A (4, 44.4%)
B (0, 0.0%)
c (5, 55.6%)
D (0, 0.0%)
E (0, 0.0%)
Q9 A (0, 0.0%)
B (0, 0.0%)
c (0, 0.0%)
D (9, 100.0o/o) E (0, 0.0%)
Q 10 A (9, 100.0o/o) B (0, 0.0%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 11 A (0, 0.0%)
B (9, 100.0o/o) C (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 12 A (2, 22.2%)
B (0, 0.0%)
c (7, 77.8%}
D (0, 0.0%)
E (0, 0.0%)
Q 13 A (8, 88.9%)
B (1, 11.1%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 14 A (0, 0.0%)
B (0, 0.0%)
C (9, 100.0o/o) D (0, 0.0%)
E (0, 0.0%)
Q 15 A (0, 0.0%)
B (0, 0.0%)
c (0, 0.0%)
D (9, 100.0o/o) E (0, 0.0%)
Q 16 A (9, 100.0o/o) B (0, 0.0%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 17 A (3, 33.3%)
B (0, 0.0%)
c (6, 66.7%)
D (0, 0.0%)
E (0, 0.0%)
Q 18 A (3, 33.3%)
B (1, 11.1%)
c (5, 55.6%)
D (0, 0.0%)
E (0, 0.0%)
Q 19 A (0, 0.0%)
B (0, 0.0%)
c (0, 0.0%)
D (9, 100.0o/o) E (0, 0.0%)
Q 20 A (8, 88.9%)
B (0, 0.0%)
c (0, 0.0%)
D (1, 11.1%)
E (0, 0.0%)
Q 21 A (0, 0.0%)
B (5, 55.6%)
c (0, 0.0%)
D (4, 44.4%)
E (0, 0.0%)
Q 22 A (7, 77.8%)
B (0, 0.0%)
c (2, 22.2%)
D (0, 0.0%)
E (0, 0.0%}
Q 23 A (0, 0.0%)
B (0, 0.0%)
c (0, 0.0%)
D (9, 100.0o/o) E (0, 0.0%)
Q 24 A (9, 100.0o/o) B (0, 0.0%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 25 A (O, 0.0%}
B (0, 0.0%)
c (0, 0.0%)
D (9, 100.0%} E (0, 0.0%)
Q 26 A (1, 11.1%)
B (8, 88.9%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%}
Q 27 A (9, 100.0o/o) B (0, 0.0%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Report run date: 3/29/2017 9:01 AM Multiples Point Biserial 0.00 0.38 0.84 0.00 0.00 0.00 0.00
-0.44 0.00 0.00 0.00 0.84
-0.08 0.00 0.00 0.00
-0.29 0.01 0.00
-0.17 0.53 0.17 0.00 0.00 0.00 0.66 0.00 Class Average:
Class Median:
KR20:
Correct 9, 100.0%
8, 88.9%
7, 77.8%
9, 100.0%
9, 100.0%
9, 100.0%
9, 100.0%
5, 55.6%
9, 100.0%
9, 100.0%
9, 100.0%
7, 77.8%
8, 88.9%
9, 100.0%
9, 100.0%
9, 100.0%
6, 66.7%
1, 11.1%
9, 100.0%
8, 88.9%
5, 55.6%
2, 22.2%
9, 100.0%
9, 100.0%
9, 100.0%
8, 88.9%
87.00 - 87.00%
87.5 - 87.50%
0.580 Percent Incorrect I
0.0%
I I
11.1%
I 22.2%
I 0.0%
I 0.0%
0.0%
0.0%
..*. *. ;;4~.4%
0.0%
0.0%
0.0%
I 22.2%
I 11.1%
I 0.0%
I 0.0%
I 0.0%
I
'>: 33.3%
I ~:,:r* ;s~,9%
I 0.0%
I 11.1%
l>~i;20.;':1,.,.,.4%
I.,,.,
..,.n.a%
I 0.0%
I 0.0%
I 0.0%
I 11.1%
9, 100.0%
I 0.0%
Page 1
Instructor:
Exam Name:
Exam Date:
Wednesday, March 29, 2017 Correct answers are shown in bold and italics Total Possible:
100 Highest Score: 91 - 91.00%
Lowest Score:
79 - 79. 00%
Blanks Q 28 A (0, 0.0%)
B (0, 0.0%)
C (9, 100.0o/a) D (0, 0.0%)
E (0, 0.0%)
Q 29 A (0, 0.0%)
B (9,.100.0o/a) C (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 30 A (0, 0.0%)
B (1, 11.1%)
C (8, 88.90/o)
D (0, 0.0%)
E (0, 0.0%)
Q 31 A (O, 0.0%)
B (0, 0.0%)
c (0, 0.0%)
D (9,.100.0o/a) E (0, 0.0%)
Q 32 A (9,.100.0o/o) B (0, 0.0%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 33 A (0, 0.0%)
B (0, 0.0%)
c (0, 0.0%)
D (9, 100.0o/a) E (0, 0.0%)
Q34 A(l,11.1%)
B (0, 0.0%)
c (8, 88.90/o)
D (0, 0.0%)
E (0, 0.0%)
Q 35 A (0, 0.0%)
B (9, 100.0o/a) C (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 36 A (0, 0.0%)
B (0, 0.0%)
c (7, 77.8%)
D (2, 22.2%)
E (0, 0.0%)
Q 37 A (0, 0.0%)
B (0, 0.0%)
c (0, 0.0%)
D (9, 100.0o/a) E (0, 0.0%)
Q 38 A (0, 0.0%)
B (0, 0.0%)
c (8, 88.90/o)
D (1, 11.1%)
E (0, 0.0%)
Q 39 A (8, 88.9%)
B (0, 0.0%)
c (1, 11.1%)
D (0, 0.0%)
E (0, 0.0%)
Q 40 A (0, 0.0%)
B (7, 77.80/o) c (0, 0.0%)
D (2, 22.2%)
E (0, 0.0%)
Q 41 A (9, 100.0o/o) B (0, 0.0%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 42 A (0, 0.0%)
B (9, 100.0o/o) C (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 43 A (0, 0.0%)
B (0, 0.0%)
c (0, 0.0%)
D (9, 100.0o/a) E (0, 0.0%)
Q 44 A (3, 33.3%)
B (6, 66.7%) c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 45 A (8, 88.9%)
B (1, 11.1%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 46 A (0, 0.0%)
B (1, 11.1%)
c (7, 77.80/o)
D (1, 11.1%)
E (0, 0.0%)
Q 47 A (0, 0.0%)
B (0, 0.0%)
C (9, 100.0o/a) D (0, 0.0%)
E (0, 0.0%)
Q 48 A (0, 0.0%)
B (1, 11.1%)
c (0, 0.0%)
D (8, 88.9%)
E (0, 0.0%)
Q 49 A (0, 0.0%)
B (9, 100.0%) C (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 50 A (0, 0.0%)
B (9, 100.0o/o) C (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 51 A (9, 100.00/o) B (0, 0.0%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 52 A (2, 22.2%)
B (7, 77.8%) c (0, 0.0%)
D (0, 0.0%)
E (O, 0.0%)
Q 53 A (3, 33.3%)
B (0, 0.0%)
c (6, 66.7%)
D (0, 0.0%)
E (0, 0.0%)
Q 54 A (1, 11.1%)
B (0, 0.0%)
C (7, 77.Bo/o)
D (1, 11.1%)
E (0, 0.0%)
Report run date: 3/29/2017 9:01 AM Multiples Point Biserial 0.00 0.00 0.66 0.00 0.00 0.00
-0.34 0.00 0.24 0.00 0.66
-0.08 0.38 0.00 0.00 0.00 0.31 0.66 0.84 0.00 0.10 0.00 0.00 0.00 0.03 0.31 0.24 Class Average:
87.00 - 87.00%
87.5 - 87.50%
0.580 Class Median:
KR20:
Correct Percent Incorrect 9, 100.0%
I 0.0%
9, 100.0%
I 0.0%
8, 88.9%
11.1%
9, 100.0%
0.0%
9, 100.0%
0.0%
9, 100.0%
0.0%
8, 88.9%
11.1%
9, 100.0%
0.0%
7, 77.8%
22.2%
9, 100.0%
0.0%
8, 88.9%
11.1%
8, 88.9%
I <T 11.1%
7, 77.8%
I**
22.2%
9, 100.0%
I 0.0%
9, 100.0%
I 0.0%
9, 100.0%
I 0.0%
6, 66.7%
I *':.,..,ce:q 33.3%
8, 88.9%
I 11.1%
7, 77.8%
I 22.2%
9, 100.0%
I 0.0%
8, 88.9%
I,
11.1%
9, 100.0%
0.0%
9, 100.0%
0.0%
9, 100.0%
0.0%
7, 77.8%
22.2%
3, 33.3%
1****,*
- : :: 66.-7°/o:
7, 77.8%
I 22.2%
Page 2
Instructor:
Total Possible:
Exam Name:
Highest Score:
Exam Date:
Wednesday, March 29, 2017 Lowest Score:
Correct answers are shown in bold and italics Q SS A (4, 44.4%)
B (0, 0.0%)
c (0, 0.0%)
D (5, 55.6%) E (0, 0.0%)
Q S6 A (0, 0.0%)
8 (9, 100.0%) c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q S7 A (0, 0.0%)
B (0, 0.0%)
c (1, 11.1%)
D (8, 88.9%)
E (0, 0.0%)
Q 58 A (0, 0.0%)
B (0, 0.0%)
C (9, 100.0%) D (0, 0.0%)
E (0, 0.0%)
Q 59 A (0, 0.0%)
8 (8, 88.9%) c (0, 0.0%)
D (1, 11.1%)
E (0, 0.0%)
Q 60 A (0, 0.0%)
B (0, 0.0%)
c (0, 0.0%)
D (9, 100.0%) E (0, 0.0%)
Q 61 A (0, 0.0%)
B (0, 0.0%)
C (9, 100.0%) D (0, 0.0%)
E (0, 0.0%)
Q 62 A (1, 11.1%)
B (0, 0.0%)
c (0, 0.0%)
D (8, 88.9%)
E (0, 0.0%)
Q 63 A (0, 0.0%)
B (6, 66.7%) c (2, 22.2%)
D (1, 11.1%)
E {O, 0.0%)
Q 64 A (0, 0.0%)
B (0, 0.0%)
c (0, 0.0%)
D (9, 100.0%) E (0, 0.0%)
Q 65 A (9, 100.0%) B (0, 0.0%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 66 A (1, 11.1%)
B {O, 0.0%)
C {O, 0.0%)
D (8, 88.9%)
E (O, 0.0%)
Q 67 A (0, 0.0%)
B (0, 0.0%)
C (9, 100.0%) D (0, 0.0%)
E (0, 0.0%)
Q 68 A (0, 0.0%)
B (7, 77.8%) c (0, 0.0%)
D (2, 22.2%)
E (0, 0.0%)
Q 69 A (9, 100.0%) B (0, 0.0%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 70 A (0, 0.0%)
B (1, 11.1%)
c (0, 0.0%)
D (8, 88.9%)
E (0, 0.0%)
Q 71 A (0, 0.0%)
B (9, 100.0%) C (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 72 A (0, 0.0%)
B (9, 100.0%) C (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 73 A (0, 0.0%)
B (0, 0.0%)
C (9, 100.00/o) D (0, 0.0%)
E (0, 0.0%)
Q 74 A (9, 100.0%) B (0, 0.0%)
C (O, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 75 A (0, 0.0%)
8 (9, 100.0%) c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 76 A (0, 0.0%)
B (0, 0.0%)
C (9, 100.00/o) D (0, 0.0%)
E (0, 0.0%)
Q 77 A (0, 0.0%)
B (9, 100.0%) C (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 78 A (7, 77.8%)
B (2, 22.2%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
Q 79 A (0, 0.0%)
B (0, 0.0%)
c (8, 88.9%)
D (1, 11.1%)
E (0, 0.0%)
Q 80 A (0, 0.0%)
B (1, 11.1%)
C (O, 0.0%)
D (8, 88.9%)
E (0, 0.0%)
Q 81 A (0, 0.0%)
B (0, 0.0%)
c (1, 11.1%)
D (8, 88.9%)
E (0, 0.0%)
Report run date: 3/29/2017 9:01 AM 100 91 - 91.00%
79 - 79.00%
Blanks Class Average:
Class Median:
KR20:
Multiples Point Correct Biserial
-0.23 s, SS.6%
0.00 9, 100.0%
-0.08 8, 88.9%
0.00 9, 100.0%
0.66 8, 88.9%
0.00 9, 100.0%
0.00 9, 100.0%
-0.34 8, 88.9%
0.00 6, 66.7%
0.00 9, 100.0%
0.00 9, 100.0%
-0.17 8, 88.9%
0.00 9, 100.0%
-0.23 7, 77.8%
0.00 9, 100.0%
-0.42 8, 88.9%
0.00 9, 100.0%
0.00 9, 100.0%
0.00 9, 100.0%
0.00 9, 100.0%
0.00 9, 100.0%
0.00 9, 100.0%
0.00 9, 100.0%
0.17 7, 77.8%
0.19 1, 11.1%
-0.34 8, 88.9%
0.66 8, 88.9%
87.00 - 87.00%
87.5 - 87.50%
0.580 Percent Incorrect
.. :,;, 44.4%
0.0%
11.1%
0.0%
11.1%
0.0%
0.0%
11.1%
- 'J)i 33.3%
0.0%
0.0%
11.1%
0.0%
22.2%
0.0%
,'?
11.1%
0.0%
0.0%
I 0.0%
0.0%
0.0%
0.0%
0.0%
22.2%
- ...*,:,,; 88~9%
11.1%
11.1%
Page 3
Instructor:
Total Possible:
100 Class Average:
87.00 - 87.00%
Exam Name:
Highest Score:
91 - 91.00%
Class Median:
87.5 - 87.50%
Exam Date:
Wednesday, March 29, 2017 Lowest Score:
79 - 79.00%
KR20:
0.580 Correct answers are shown in bold and italics Blanks Multiples Point Correct Percent Incorrect Biserial Q 82 A (8, 88.9%)
B (1, 11.1%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
0.66 8, 88.9%
I ;
11.1%
I Q 83 A (0, 0.0%)
B (0, 0.0%)
C (9, 100.0%) D (0, 0.0%)
E (0, 0.0%)
0.00 9, 100.0%
I 0.0%
I Q 84 A (0, 0.0%)
B (2, 22.2%)
c (2, 22.2%)
D (5, 55.6%)
E (0, 0.0%)
-0.39 5, 55.6%
l:*<t:J* 44 4°/c
- ,.; -~: '. <~;.:~:t;'~. <,
- 0 I
Q 85 A (0, 0.0%)
B (1, 11.1%)
c (8, 88.9%)
D (0, 0.0%)
E (0, 0.0%)
0.00 0, 0.0%
I
- '{f\\~Y;!H90,0% ~
- '
Q 86 A (0, 0.0%)
B (9, 100.0%) C (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
0.00 9, 100.0%
I 0.0%
Q 87 A (4, 44.4%)
B (0, 0.0%)
C(5, 55.6%)
D (O, 0.0%)
E (0, 0.0%)
0.04 5, 55.6%
- ,;;<y, '* 4~.4%
Q 88 A (0, 0.0%)
8 (9, 100.0%) c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
0.00 9, 100.0%
0.0%
Q 89 A (9, 100.0%) B (0, 0.0%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
0.00 9, 100.0%
0.0%
Q 90 A (0, 0.0%)
B (9, 100.0%} C (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
0.00 9, 100.0%
0.0%
Q 91 A (4, 44.4%)
B (4, 44.4%)
c (1, 11.1%)
D (0, 0.0%)
E (0, 0.0%)
0.53 4, 44.4%
I**:;: I 'i *55}6%
Q 92 A (0, 0.0%)
B (0, 0.0%)
c (0, 0.0%)
D (9, 100.0%) E (0, 0.0%)
0.00 9, 100.0%
I 0.0%
Q 93 A (O, 0.0%)
B (O, 0.0%)
c (0, 0.0%)
D (9, 100.0%) E (0, 0.0%)
0.00 9, 100.0%
I 0.0%
Q 94 A (0, 0.0%)
B (0, 0.0%)
c (1, 11.1%)
D (8, 88.9%)
E (0, 0.0%)
0.10 8, 88.9%
I 11.1%
Q 95 A (1, 11.1%)
B (0, 0.0%)
C(8, 88.9%)
D (0, 0.0%)
E (0, 0.0%)
-0.17 8, 88.9%
11.1%
Q 96 A (0, 0.0%)
B (3, 33.3%)
c (0, 0.0%)
D (6, 66.7%)
E (0, 0.0%)
-0.50 6, 66.7%
'. 33.3%
Q 97 A (8, 88.9%)
B (1, 11.1%)
c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
0.38 8, 88.9%
11.1%
Q 98 A (0, 0.0%)
B (3, 33.3%)
c (6, 66.7%)
D (0, 0.0%)
E (0, 0.0%)
0.12 6, 66.7%
- \\C, ',
- ; 33,3%
Q 99 A (0, 0.0%)
8 (9, 100.0%) c (0, 0.0%)
D (0, 0.0%)
E (0, 0.0%)
0.00 9, 100.0%
0.0%
Q 100 A (0, 0.0%)
B (0, 0.0%)
C (9, 100.0%) D (0, 0.0%)
E (0, 0.0%)
0.00 9, 100.0%
0.0%
Report run date: 3/29/2017 9:01 AM Page 4
- 111.
Exelon Generation,,
January 18, 2017 Mr. David Silk U.S. NRC Region 1 2100 Renaissance Boulevard Renaissance Park King of Prussia, PA 19406 R.E. Ginna Nuclear Power Plant Renewed Facility Operating License No. DPR-18 NRC Docket No. 50-244 Jot' Pacher Site ViCL' Prc:-.idc111 R.F. Ciinna.Nuckar Power Plant I '.\\0.' I.ale Rd.
Ontario. NY 1-t.'il'!
31 5 791 5200 Office 585 545 1586 Mobile WW\\.\\'.t:X(' loth.'OfJl.L'Olll jo\\L'11h. pa.: her (a, e \\L' !1i11'.:: orp. Clim
Subject:
Submittal of Integrated Initial License Examination Materials Enclosed are the examination materials, which RE. Ginna is submitting in support of the initial license exam scheduled for the weeks of March 13 and 20, 2017, at Ginna Station.
This submittal includes the Senior Reactor Operator and Reactor Operator Written Examinations, Job Performance Measures, and Integrated Plant Operation Scenario Guides.
These examination materials have been developed in accordance with NUREG-1021, "Operator Licensing Examination Standards for Power Reactors", Revision 10. Please note that reference materials are attached to each individual examination question or item.
Some minor modifications have been made to the Integrated Examination Outline with regards to the operational scenarios in order to improve balance and content. These changes improve examination quality and are in compliance with NUREG-1021, "Operator Licensing Examination Standards for Power Reactors", Revision 10.
Some modifications or adjustments to the examination material may be required due to procedural changes.
In accordance with NUREG-1021, Revision 10, Section ES-201, "Initial Operator Licensing Examination Process", please ensure that these materials are withheld from public disclosure for 2 years after the examinations are complete.
Should you have any questions concerning this letter, please contact Thomas Harding, Manager Site Regulatory Assurance, at (315)791-5219. For questions concerning examination materials, please contact David Eckert, Exam Author, at (315)791-5523.
R(!tfu'J' /l_
~p~ E. Pacher
Enclosures:
(mail to Dave Silk, Chief Examiner, NRC Region I)
DVD containing:
Form ES-401-5, RO/SRO Composite Examination Form ES-C-1, Control Room Systems and Facility Walk-Through Job Performance Measure Form ES-C-1, Administrative Topic Job Performance Measure Form ES-D-1, Scenario Outline, Scenario #1 (N17-1-6)
Form ES-D-2, Integrated Plant Operation Scenario Guide, Scenario #1 (N17-1-6)
Form ES-D-1, Scenario Outline, Scenario #2 (Nl7-1-3)
Form ES-D-2, Integrated Plant Operation Scenario Guide, Scenario #2 (Nl 7-1-3)
Form ES-D-1, Scenario Outline, Scenario #3 (Nl 7-1-5)
Form ES-D-2, Integrated Plant Operation Scenario Guide, Scenario #3 (N17-1-5)
Form ES-D-1, Scenario Outline, Scenario #4 (N17-1-l)
Form ES-D-2, Integrated Plant Operation Scenario Guide, Scenario #4 (N17-1-l)
Form ES-D-1, Scenario Outline, Scenario #5 (Spare) (N17-l-4)
Form ES-D-2, Integrated Plant Operation Scenario Guide, Scenario #5 (Spare) (Nl7-l-4) 2 Binders containing RO/SRO Written Examination references Binder containing Administrative Topic Job Performance Measure references Form ES-201-2, Examination Outline Quality Checklist Form ES-201-3, Examination Security Agreements (current)
Form ES-301-1, Administrative Topics Outline for RO Form ES-301-2, Control Room/In-Plant Systems Outline for RO Form ES-301-1, Administrative Topics Outline for SRO Form ES-301-2, Control Room/In-Plant Systems Outline for SRO(I)
Form ES-301-2, Control Room/In-Plant Systems Outline for SRO(U)
Form ES-301-3, Operating Test Quality Checklist Form ES-301-4, Simulator Scenario Quality Checklist Form ES-301-5, Transient and Event Checklist Form ES-301-6, Competencies Checklist Form ES-401-2, PWR Examination Outline (RO and SRO)
Form ES-401-3, Generic Knowledge and Abilities Outline (Tier 3)
Form ES-401-4, Record of Rejected Kl As Form ES-401-6, Written Examination Quality Checklist cc:
(without enclosures)
Branch Chief, Operator Licensing, Region 1 - Mr. Donald Jackson NRC Senior Resident Inspector - Ginna Station - Mr. Neil Perry Bee:
(without enclosures)
Site Vice President Manager - Site Regulatory Assurance Training Director
Exelon Generation December 09, 2016 Mr. David Silk U.S. NRC Region 1 2100 Renaissance Boulevard Renaissance Park King of Prussia, PA 19406 R.E. Ginna Nuclear Power Plant Renewed Facility Operating License No. DPR-18 NRC Docket No. 50-244 Jot* Padll'r S1k' \\ il'1..' Pr1._dt.k11t R.I. ( i11111a NLll'k*a1 l'm\\1..*1 Plan!
I 'i()l I <1kc* Rd Onwrin '\\IY 1--1-.::; j()
~ 1.::::, 7q I."i.2()() ( )ffJlT
.::;s.
.::. "-l" I )8h l\\1oh1k
\\\\ \\\\ \\\\ 1..'\\1._'lo11u1rp.nn11
Subject:
Submittal of Initial Operator Licensing Examination Outline Enclosed are the examination outlines, supporting the initial license exam scheduled during the weeks of March 13 and 20, 2017 at Ginna Station.
This submittal includes all appropriate examination standard forms and outlines in accordance with NUREG-1021, "Operator Licensing Examination Standards for Power Reactors', Revision 10. Also enclosed is the proposed examination schedule for the licensing exam.
In accordance with NUREG-1021, Revision 10, Section ES-201, "Initial Operator Licensing Examination Process", please ensure that these materials are withheld from public disclosure for 2 years after the examinations are complete.
Should you have any questions concerning this letter, please contact Thomas Harding, Manager Site Regulatory Assurance, at (315)791-5219. For questions concerning examination materials, please contact David Eckert, Exam Author, at (315)791-5523.
seph E. Pacher
Enclosures:
(mail to Dave Silk, Chief Examiner, NRC Region I)
Form ES-201-2, Examination Outline Quality Checklist Form ES-201-3, Examination Security Agreements (currently)
Form ES-301-1, Administrative Topics Outline for RO Form ES-301-2, Control Room/In-Plant Systems Outline for RO Form ES-301-1, Administrative Topics Outline for SRO Form ES-301-2, Control Room/In-Plant Systems Outline for SRO(I)
Form ES-301-2, Control Room/In-Plant Systems Outline for SRO(U)
Form ES-301-5, Transient and Event Checklist Form ES-401-2, PWR Examination Outline (RO and SRO)
Form ES-401-3, Generic Knowledge and Abilities Outline (Tier 3)
Statement detailing method of Written Examination Outline generation Form ES-401-4, Record of Rejected K/As Form ES-D-1, Scenario Outline, Scenario #1 Form ES-D-1, Scenario Outline, Scenario #2 Form ES-D-1, Scenario Outline, Scenario #3 Form ES-D-1, Scenario Outline, Scenario #4 Form ES-D-1, Scenario Outline, Scenario #5 (Spare)
LC 15-1 CERT Exam Outlines cc:
(without enclosures)
Branch Chief, Operator Licensing, Region 1 - Mr. Donald Jackson NRC Senior Resident Inspector-Ginna Station - Mr. Neil Perry NRR Project Manager - Mrs. Brenda Mozafari Bee:
(without enclosures)
Site Vice President Manager - Site Regulatory Assurance Training Director
2017 ILT NRC Exam Outline Generation Methodology The following method was used to generate the INITIAL outline submitted to the NRC for this exam:
A. NUREG-1122, unsuppressed K/A statements and the list of Rejected K/As from the 2014 ILT NRC Exam were reviewed for possible addition/removal to the Suppressed K/ A listing.
B.
The Suppressed K/As sent to the Chief Examiner (Dave Silk) on 05/11/2016 were suppressed in the NKEG software program database.
C.
The Westinghouse NRC KA Exam Generator software program (NKEG), Version 1.1, is loaded on the stand-alone exam development computer. This software application provides a means of accessing Revision 2 versions of NUREG-1122, Knowledge and Abilities Catalog for Nuclear Power Plant Operators. A random exam outline was generated on 08/05/2016 for the RO and SRO sections of the ILT Exam.
D. The random outline from NKEG was manually inputted into an Excel spreadsheet that verifies ES-401-2 requirements are met. No issues were noted.
E.
On 11/22/2016, discussed with the Chief Examiner (Dave Silk) rejecting K/A 039 2.2.39 due to no Technical Specification Action Statements less than or equal to one hour exist for the Main Steam system. A replacement K/A for System 039 was selected by determining the number of remaining K/As and randomly selecting a numbered chip.
F.
On 12/5/2016, the replacement K/A was manually inputted into an Excel spreadsheet that verifies ES-401-2 requirements are met. No issues were noted.
This was the method I used to generate the random outline used to develop the ILT NRC Exam.