| issue date = 05/21/1980
| title = LER 80-027/09T-0:on 800514,during Shutdown for Maint,Nsss Notified Util That Partial Draining of RCS While in Mode 5 Is Condition That Has Not Been Analyzed for Boron Dilution Event.Procedures Revised to Increase Min Shutdown Margin
| title = LER 80-027/09T-0:on 800514,during Shutdown for Maint,Nsss Notified Util That Partial Draining of RCS While in Mode 5 Is Condition That Has Not Been Analyzed for Boron Dilution Event.Procedures Revised to Increase Min Shutdown Margin
| author name = SCHOPPMAN M A
| author name = Schoppman M
| author affiliation = FLORIDA POWER & LIGHT CO.
| author affiliation = FLORIDA POWER & LIGHT CO.
| addressee name =  
| addressee name =  
Line 18: Line 18:


=Text=
=Text=
{{#Wiki_filter:NBCPOR941SsaITnILECENSEEEVENTREPORTU.SNUCLEARREGULATORYCC44MISSIONCQNTROISLCCXIIFELISILESI134LYCSNSSSCOOSEE'IQIIPLP~SPRINTCRTYPcALI.REQUIREDINPORAIATIONI5IQ011-1011901010I.I10Qi11IIIIIIQA~IQ14III2459,4si4M4iB~53'4922,fPP4052~453CCN40E~0'"-0..;;12Q0saialii9s9'Q~ZIsiQai51211!50Slccc)cei.'4UAlssRBa.32svsNTCATsryB~~BTCATS30=VEi4T'DESCRIPTION9NOPROS*EL.ECONSEQUENCESQIO)DurinshutdownformaintenancetheNSSSnotifiedFPthtoartialdrain-inoftheRCSwhileinNode5isaconditionthathasnotbeenanalzedfortheborondilutionevent.Reduced'RCS"volumewouldresultin~35aredictedtilmetocriticalit1essthantheassumedtimeeriodforoeratoractionassumintheT.S.minimumshutdownmarinoflAhoexistedattheonsetoftheevent.ThisisreportableunderT.S.6.9.1.8becauseapartialldrainedRCSislessconservativethananalzedinthe.FSAR.7305VSTS'ffCAUS%CAUS%C94MPVAI.V9CQQSCocaSU%COOSCCMPCNSNTCOOS'USQQSSUBCQOSLzZziiQzz~BQIz~AQ90zzziz1z2Qa~zQsa~zGa790Ih11IJ12191922SSOUSNTIAIOCC9IBB%94CSBSPCBTBSVISIOH212222IS21~529302132ACTIONPUTVBSSPP%C514UTCOVINATTACHMSNTNPAC44PBIAPSCQMPCQMPQHSNTTAIISNACTIQ'ICNPLA9'4rSISTI400~NOVAS+22SUSMITTSQPCBM%US.5VPPLISBMA'4VPAVBSBMGQMZQMZQLZJQLOO~O4lLYJQZNJQiZIQ0229991IPJ43$2$21404142JA31CAUSEDESCRIPTIONANOCORRECTIVEACTIQNSQ270InaccordancewithNSSSrecommendationrcreasetheminimumshutdownmarinfromlAhoto2Xhensures20min.timelasetocriticalitandtorecludeooeratinwicharinaumpswithaartialldrainedRCSinM005hieventofthiste.Itisalsoreortableunder10CFR1a9PACILITY.STATUS5PCVI%BMST44COOPOTNSBSTATUSQ20clscQVSBv~QSINAMEOBPRcPARER8OG603OEE.A.Schoman.iQQ>>>>Q~OI0I0Q~73101212ACTIVITYCONTCNTRKLILASSOCPBSL~PSAMOUNTOPA~iVITYQSS~I~~ZQ22~2'A'3910JAPSBSONNSLIXPOSVBSS~92~000'Qas~ZQZsINA293111212PSBSQNHSIINJUBI%20~0(l0QaaNAI39II12ICSSQPCailOAMAC290PACILITYQASCSSCBIPTICN~19~ZQ2NA233'0pvsLIcrv0i4IQ~NA3:0'~1CISCCVSBVCSSCBIPTIC942LCCATICNOPBSLSASSQSENA303030I'IRCI'SECNI.YSs5950p94QNc.3055523802 ReportableOccurrence335-80-27LicenseeEventReportPaeTwoAdditionalInformationl.Theapplicabilityofthisoccurrenceto.St.Luci.eUnit2andTurkeyPointUnits384isunderconsideration.2.ATechnicalSpecificationchangeisbeingpreparedtoaddressoperationinMode5withapartiallydrainedRCS3.EntryintoMode5isfromNodesrequiringhighershutdownmargins.Deliberatedilutionwouldbere'quiredtaa'chievetheminimumshutdownmarginspecifiedinTechnicalSpecificationsforNode5.ThehighershutdownmarginsinMode4and6andtheneedfordeliberatedilutiontoachievetheminimumNode5shutdownmarginmakesthiseventunlikely.  
{{#Wiki_filter:NBC POR941 Ssa                                                                                                                                      U. S NUCLEAR REGULATORY CC44MISSION IT  nI LECENSEE EVENT REPORT CQNTROI SLCCXI                            E    E                  IQI                        IPLP~S PRINT CR TYPc ALI. REQUIRED INPORAIATIONI I                                      5 1            3    4 FEL    I  SI LYCSNSSS COOS LES        I  I 14 Q      01      1-101 I
}}
1901 010 i
I I 2 4 5 9,4 si4M 4 B I
                                                                                                                                  . I      10
                                                                                                                                                  ~5 Qi      3 11 I  I I 4922, fPP I  I  IQA~IQ 40    52    ~4 53 CCN 0 E
                  ~
4
                                  ..;;1250          Q       Sl 0 s        ai alii ccc)cei   .'4UAlssR 9        s    9'Q~ZI Ba. 32      svsNT CATs si        Q      ry ai51211!
B~~BTCATS              30 0
                          =VEi4T'DESCRIPTION 9 NO PROS*EL.E CONSEQUENCES QIO 0  '"-        ) Durin            shutdown                for      maintenance                        the      NSSS        notified              FP        th    t  oartial drain-in of the                    RCS      while in                        Node 5              is    a  condition that                        has not been anal zed              for the              boron          dilution event.                           Reduced'RCS"volume would                                    result in
          ~35                  a    redi cted t ilme to cri tical i t 1 ess than the assumed time eri od for o er ator action assumin the T.S. minimum shutdown mar in of lA ho existed at the onset of the event . This is reportable under T.S. 6.9.1.8 because a partiall drained RCS is less conservative than anal zed in the. FSAR .
7                                                                                                                                                                                                      30 5VSTS'ff CQQS CAUS%
Coca CAUS%
SU%COOS                        CCMPCNSNT COOS                'US      C94MP QQS VAI.V9 SUBCQOS LzZ z          iiQzz      ~BQIz           ~AQ90                  z      z    zi z    1  z    2    Qa        ~zQsa           ~z      Ga 7            9                        0            Ih            11              IJ                  12                                  19          19              22 SSOUSNTIAI                                  OCC9IBB%94CS            BSPCBT                        BSVISIOH 21          22          22                                    IS          21              ~5        29          30              21            32 ACTION PUTVBS                    SPP%C            514UTCOVIN                                          ATTACHMSNT              NPAC44        PBIAPSCQMP                CQMPQHSNT TAIISN ACTIQ'I                  CNPLA9'4r            SISTI400                        NOVAS +22          SUSMITTSQ            PCBM %US.         5VPPLISB              MA'4VPA    VBSB 0229991IP
                                                                                                        ~
MGQMZQ      J4 MZQ 3$
LZJQ 2$
LOO~O 21 4l  40 LYJQ 41 ZNJQ              i 42 ZIQ          JA              31 CAUSE DESCRIPTION ANO CORRECTIVE ACTIQNS Q27 0          In accordance with NSSS recommendation                                                                        r crease the minimum shutdown mar in from lA ho to                                                                              2X h            ensures          20 min.
time la se to                        criticalit                      and          to reclude ooerati n wi char ina umps with a artiall drained RCS in M00 5                                                                                                  hi iQQ>>>>Q 7
        ~I      ~
a 3
3 9
PACILITY.
STATUS ACTIVITY CON TCNT RKLILASSO CP BSL~PS
                          ~Z 9
Q22 10 10 5 PCVI% B
                                          ~OI 0
                                          ~2'A' PSBSONNSL IXPOSVBSS I   0 12 Q~
event of this t e. It is also re ortable under 10 CFR 1 12 AMOUNTOP OTNSBSTATUS Q20 A~iVITYQSS JA MST44CO OP clscQVSBv
                                                                                                                        ~QSI                    1 NA
                                                                                                                                                    ~
CISCCVSBV CSSCBIPTIC94 LCCATICN OP BSLSASS QSE 2
30
        ~92 2          9
                          ~00 3
0 11
                                              'Qas   ~ZQZs 12 I
12 NA PSBSQNHSI INJUBI%2 I
0 3
                          ~0(l 9
0 II Qaa 12 NA 30 I CSS QP Cail OAMAC2 9 0 PACI LITY CSSCBIPTICN                      QAS
        ~19 ~ZQ2 2          3    3      '0 pvsLIcrv NA I'IRC I'SE CNI.Y 30 0        i4 IQ~ :0'                                                                   NA 3                                                                                                                                                      Ss    59                            50 NAME OB PRcPARER                          EE. A. Scho                    man                                        p94QNc.       305        552 3802 8 OG603O
 
Reportable Occurrence 335-80-27 Licensee Event Report Pa e Two Additional Information
: l. The  applicability of this occurrence  to. St. Luci.e Unit 2 and Turkey Point Units  3 8 4 is under consideration.
: 2. A  Technical Specification change is being prepared to address operation in  Mode 5 with a partially drained RCS
: 3. Entry into Mode 5 is from Nodes requiring higher shutdown margins.
Deliberate dilution would be re'quired ta a'chieve the minimum shutdown margin specified in Technical Specifications for Node 5.
The higher shutdown margins in Mode 4 and 6 and the need for deliberate dilution to achieve the minimum Node 5 shutdown margin makes this event unlikely.}}

Latest revision as of 10:03, 4 February 2020

LER 80-027/09T-0:on 800514,during Shutdown for Maint,Nsss Notified Util That Partial Draining of RCS While in Mode 5 Is Condition That Has Not Been Analyzed for Boron Dilution Event.Procedures Revised to Increase Min Shutdown Margin
ML17266A210
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 05/21/1980
From: Schoppman M
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML17208A673 List:
References
REF-PT21-80-220-001 LER-80-027-09T, LER-80-27-9T, NUDOCS 8006030449
Download: ML17266A210 (2)


Text

NBC POR941 Ssa U. S NUCLEAR REGULATORY CC44MISSION IT nI LECENSEE EVENT REPORT CQNTROI SLCCXI E E IQI IPLP~S PRINT CR TYPc ALI. REQUIRED INPORAIATIONI I 5 1 3 4 FEL I SI LYCSNSSS COOS LES I I 14 Q 01 1-101 I

1901 010 i

I I 2 4 5 9,4 si4M 4 B I

. I 10

~5 Qi 3 11 I I I 4922, fPP I I IQA~IQ 40 52 ~4 53 CCN 0 E

~

4

..;;1250 Q Sl 0 s ai alii ccc)cei .'4UAlssR 9 s 9'Q~ZI Ba. 32 svsNT CATs si Q ry ai51211!

B~~BTCATS 30 0

=VEi4T'DESCRIPTION 9 NO PROS*EL.E CONSEQUENCES QIO 0 '"- ) Durin shutdown for maintenance the NSSS notified FP th t oartial drain-in of the RCS while in Node 5 is a condition that has not been anal zed for the boron dilution event. Reduced'RCS"volume would result in

~35 a redi cted t ilme to cri tical i t 1 ess than the assumed time eri od for o er ator action assumin the T.S. minimum shutdown mar in of lA ho existed at the onset of the event . This is reportable under T.S. 6.9.1.8 because a partiall drained RCS is less conservative than anal zed in the. FSAR .

7 30 5VSTS'ff CQQS CAUS%

Coca CAUS%

SU%COOS CCMPCNSNT COOS 'US C94MP QQS VAI.V9 SUBCQOS LzZ z iiQzz ~BQIz ~AQ90 z z zi z 1 z 2 Qa ~zQsa ~z Ga 7 9 0 Ih 11 IJ 12 19 19 22 SSOUSNTIAI OCC9IBB%94CS BSPCBT BSVISIOH 21 22 22 IS 21 ~5 29 30 21 32 ACTION PUTVBS SPP%C 514UTCOVIN ATTACHMSNT NPAC44 PBIAPSCQMP CQMPQHSNT TAIISN ACTIQ'I CNPLA9'4r SISTI400 NOVAS +22 SUSMITTSQ PCBM %US. 5VPPLISB MA'4VPA VBSB 0229991IP

~

MGQMZQ J4 MZQ 3$

LZJQ 2$

LOO~O 21 4l 40 LYJQ 41 ZNJQ i 42 ZIQ JA 31 CAUSE DESCRIPTION ANO CORRECTIVE ACTIQNS Q27 0 In accordance with NSSS recommendation r crease the minimum shutdown mar in from lA ho to 2X h ensures 20 min.

time la se to criticalit and to reclude ooerati n wi char ina umps with a artiall drained RCS in M00 5 hi iQQ>>>>Q 7

~I ~

a 3

3 9

PACILITY.

STATUS ACTIVITY CON TCNT RKLILASSO CP BSL~PS

~Z 9

Q22 10 10 5 PCVI% B

~OI 0

~2'A' PSBSONNSL IXPOSVBSS I 0 12 Q~

event of this t e. It is also re ortable under 10 CFR 1 12 AMOUNTOP OTNSBSTATUS Q20 A~iVITYQSS JA MST44CO OP clscQVSBv

~QSI 1 NA

~

CISCCVSBV CSSCBIPTIC94 LCCATICN OP BSLSASS QSE 2

30

~92 2 9

~00 3

0 11

'Qas ~ZQZs 12 I

12 NA PSBSQNHSI INJUBI%2 I

0 3

~0(l 9

0 II Qaa 12 NA 30 I CSS QP Cail OAMAC2 9 0 PACI LITY CSSCBIPTICN QAS

~19 ~ZQ2 2 3 3 '0 pvsLIcrv NA I'IRC I'SE CNI.Y 30 0 i4 IQ~ :0' NA 3 Ss 59 50 NAME OB PRcPARER EE. A. Scho man p94QNc. 305 552 3802 8 OG603O

Reportable Occurrence 335-80-27 Licensee Event Report Pa e Two Additional Information

l. The applicability of this occurrence to. St. Luci.e Unit 2 and Turkey Point Units 3 8 4 is under consideration.
2. A Technical Specification change is being prepared to address operation in Mode 5 with a partially drained RCS
3. Entry into Mode 5 is from Nodes requiring higher shutdown margins.

Deliberate dilution would be re'quired ta a'chieve the minimum shutdown margin specified in Technical Specifications for Node 5.

The higher shutdown margins in Mode 4 and 6 and the need for deliberate dilution to achieve the minimum Node 5 shutdown margin makes this event unlikely.