{{#Wiki_filter:
{{#Wiki_filter:ary 30, 2012
[[Issue date::January 30, 2012]]


Mr. Michael J. Pacilio, Senior Vice President Exelon Generation Company, LLC President and Chief Nuclear Officer, Exelon Nuclear 4300 Winfield Road Warrenville, IL 60555
==SUBJECT:==
LIMERICK GENERATING STATION, UNITS 1 AND 2 - NRC SECURITY INSPECTION REPORT 05000352/2012201 AND 05000353/2012201


SUBJECT: LIMERICK GENERATING STATION, UNITS 1 AND 2 - NRC SECURITY INSPECTION REPORT 05000352/2012201 AND 05000353/2012201
==Dear Mr. Pacilio:==
On January 11, 2012, the U.S. Nuclear Regulatory Commission (NRC) completed a security baseline inspection at the Limerick Generating Station, Units 1 and 2. The inspection covered one or more of the key attributes of the security cornerstone of the NRCs Reactor Oversight Process. The enclosed inspection report documents the inspection results, which were discussed on January 11, 2012, with Mr. B. Maguire, Site Vice President, and other members of your staff.


==Dear Mr. Pacilio:==
The inspection examined activities conducted under your license as they relate to security and compliance with the Commissions rules and regulations and with the conditions of your license.
On January 11, 2012, the U.S. Nuclear Regulatory Commission (NRC) completed a security baseline inspection at the Limerick Generating Station, Units 1 and 2. The inspection covered one or more of the key attributes of the security cornerstone of the NRC's Reactor Oversight Process. The enclosed inspection report documents the inspection results, which were discussed on January 11, 2012, with Mr. B. Maguire, Site Vice President, and other members of your staff. The inspection examined activities conducted under your license as they relate to security and compliance with the Commission's rules and regulations and with the conditions of your license.


The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel. Based on the results of this inspection, no findings of significance were identified.
The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel.


In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). However, because of the security-related information contained in the enclosure, and in accordance with 10 CFR 2.390, a copy of this letter's enclosure will not be available for public inspection. In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response, if any. This practice will ensure that your response will not be made available electronically for public inspection in the NRC Public Document Room or from the NRC's document system, ADAMS. If Safeguards Information is necessary to provide an acceptable response, please provide the level of protection described in 10 CFR 73.21. Otherwise, mark your entire response "Security-Related Information - Withhold Under 10 CFR 2.390" and follow the instructions for withholding in 10 CFR 2.390(b)(1).
Based on the results of this inspection, no findings of significance were identified.


Sincerely,/RA/
In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390 of the NRC's
Garmon West, Chief Security Training and Support Branch Division of Security Operations Office of Nuclear Security and Incident Response Docket Nos. 50-352; 50-353 License Nos. NPF-39; NPF-85
"Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). However, because of the security-related information contained in the enclosure, and in accordance with 10 CFR 2.390, a copy of this letter's enclosure will not be available for public inspection.


===Enclosure:===
In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response, if any. This practice will ensure that your response will not be made available electronically for public inspection in the NRC Public Document Room or from the NRCs document system, ADAMS. If Safeguards Information is necessary to provide an acceptable response, please provide the level of protection described in 10 CFR 73.21. Otherwise, mark your entire response Security-Related Information - Withhold Under 10 CFR 2.390 and follow the instructions for withholding in 10 CFR 2.390(b)(1).
Inspection Report 05000352/2012201 and 05000353/2012201


===w/Attachments:===
Sincerely,
/RA/
Garmon West, Chief Security Training and Support Branch Division of Security Operations Office of Nuclear Security and Incident Response Docket Nos. 50-352; 50-353 License Nos. NPF-39; NPF-85 Enclosure: Inspection Report 05000352/2012201 and 05000353/2012201 w/Attachments:
Supplemental Information
Supplemental Information
}}
}}

Latest revision as of 09:23, 12 November 2019

IR 05000352-12-201, 05000353-12-201; January 9, 2012 Through January 11, 2012, Limerick Generating Station, Units 1 and 2; Target Set Inspection. Cover Letter
ML12024A011
Person / Time
Site: Limerick  Constellation icon.png
Issue date: 01/30/2012
From: West G
Division of Security Operations
To: Pacilio M
Exelon Generation Co, Exelon Nuclear
Shared Package
ML12024A010 List:
References
IR-12-201
Download: ML12024A011 (2)


Text

ary 30, 2012

SUBJECT:

LIMERICK GENERATING STATION, UNITS 1 AND 2 - NRC SECURITY INSPECTION REPORT 05000352/2012201 AND 05000353/2012201

Dear Mr. Pacilio:

On January 11, 2012, the U.S. Nuclear Regulatory Commission (NRC) completed a security baseline inspection at the Limerick Generating Station, Units 1 and 2. The inspection covered one or more of the key attributes of the security cornerstone of the NRCs Reactor Oversight Process. The enclosed inspection report documents the inspection results, which were discussed on January 11, 2012, with Mr. B. Maguire, Site Vice President, and other members of your staff.

The inspection examined activities conducted under your license as they relate to security and compliance with the Commissions rules and regulations and with the conditions of your license.

The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel.

Based on the results of this inspection, no findings of significance were identified.

In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390 of the NRC's

"Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). However, because of the security-related information contained in the enclosure, and in accordance with 10 CFR 2.390, a copy of this letter's enclosure will not be available for public inspection.

In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response, if any. This practice will ensure that your response will not be made available electronically for public inspection in the NRC Public Document Room or from the NRCs document system, ADAMS. If Safeguards Information is necessary to provide an acceptable response, please provide the level of protection described in 10 CFR 73.21. Otherwise, mark your entire response Security-Related Information - Withhold Under 10 CFR 2.390 and follow the instructions for withholding in 10 CFR 2.390(b)(1).

Sincerely,

/RA/

Garmon West, Chief Security Training and Support Branch Division of Security Operations Office of Nuclear Security and Incident Response Docket Nos. 50-352; 50-353 License Nos. NPF-39; NPF-85 Enclosure: Inspection Report 05000352/2012201 and 05000353/2012201 w/Attachments: