Line 3: Line 3:
| issue date = 07/18/1980
| issue date = 07/18/1980
| title = Forwards Re Ginna Nuclear Power Plant,Seismic Upgrading Program Piping Stress Analysis,Main Steam Sys,Section 200. Minor Design Changes or Const Mods Will Generally Not Affect Stress Results & Support Recommendations
| title = Forwards Re Ginna Nuclear Power Plant,Seismic Upgrading Program Piping Stress Analysis,Main Steam Sys,Section 200. Minor Design Changes or Const Mods Will Generally Not Affect Stress Results & Support Recommendations
| author name = NOON F
| author name = Noon F
| author affiliation = WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
| author affiliation = WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
| addressee name = LILLEY M P
| addressee name = Lilley M
| addressee affiliation = ROCHESTER GAS & ELECTRIC CORP.
| addressee affiliation = ROCHESTER GAS & ELECTRIC CORP.
| docket = 05000244
| docket = 05000244
Line 17: Line 17:


=Text=
=Text=
{{#Wiki_filter:IIestinghooseElectricCorporationINaterReactorDivisionsNuclearTechnologyOivisionBox355PittsburghPennsylvania15230July18,1980ST-SST-108RGE-80-95Mr.M.P.Lilley.RochesterGas8ElectricJ9EastAvenueRochester,HewYork14649
{{#Wiki_filter:I IIestinghoose              Nater Reactor                                Nuclear Technology Oivision Electric Corporation      Divisions                                    Box 355 Pittsburgh Pennsylvania 15230 July 18, 1980 ST-SST- 108 RGE 95 Mr. M. P. Li lley
. Rochester Gas 8 Electric J9 East Avenue Rochester, Hew York              14649


==DearMr.Lilley:==
==Dear Mr. Li lley:==
ROBERTEMMETTGINHANUCLEARGENERATINGSTATIONR,E.GinnaSeismicUpgradingProgramMainSteamStressReortTransmittedhereinisthepipingstressreportforthe'R.E.GinnaNuclearGeneratingStationUnitNo.1MainSteamSystem,Section200,SDTAR-80-05-'08..AnalysisresultsandsupportloadscontainedhereinreflectthelayoutarrangementshownonmarkedisometricC-381-350,Sheet1,RevisionC.Anysignificantmodificationstothelayoutofthissystemofpipingandoritsrestraintswillwarrantreanalysisofthispipingsystem.Minordesignchangesorconstrue.ionmodificationswillgenerallynotaffectstressresults'andsupportrecottrtendations.However,casebycasereviewofthediscrepanciescanbeusedtodetermineoverallsystembehaviorandeffects.Ifanyquestionsexistrelativetotheabo'vetransmittal,pleasecontactW.A.MassieofWestinghouse.'ytrulyyours,W.A.Massie/djAttachmentF.Noon,ManagerEasternRegionWNISupport M.P.Li1ley~+ATE-gO-5cc:R.E.Smith-'lL,1AR.C.McCredy,RGE-1L,M.P.Lilley,t<GE-1L,lAT.R.Heis,RGE<-1LB.H.Bell,GA?-'1L',lAP.N.Cameron,GAI-1L,lAB.A.Snow,RGE-1LJ.C.Hutton,RGB,-,1L,lA\'


}}
ROBERT EMMETT GINHA NUCLEAR GENERATING STATION R, E. Ginna Seismic Upgrading Program Main Steam Stress Re ort Transmitted herein is the piping stress report for the'R. E. Ginna Nuclear Generating Station Unit No. 1 Main Steam System, Section 200, SDTAR-80-05-'08..
Analysis results        and support loads contained herein reflect the layout arrangement      shown on marked isometric C-381-350, Sheet 1, Revision C. Any significant      modifications to the layout of this system of piping and or
                                          'y its restraints will warrant reanalysis          of this piping system.
Minor design changes or construe.ion modifications will generally not affect stress results 'and suppor t recottrtendations.          However, case by case review of the discrepancies can be used to determine overall system behavior and effects.
If any  questions      exist relative to the    abo've  transmittal, please contact W. A. Massie    of Westinghouse.
truly yours, F. Noon, Manager Eastern Region    WNI    Support W. A. Massie/dj Attachment
 
M. P. Li 1 ley                              ~
                                              +ATE-gO-5 cc: R. E. Smith - 'lL, 1A R. C. McCredy, RGE - 1L, M. P. Lilley,  t<GE - 1L, lA T. R. Hei s, RGE<- 1L B. H. Bell, GA? -'1 L', lA P. N. Cameron, GAI - 1L, lA B. A. Snow, RGE - 1L J. C. Hutton,  RGB,
                                  , 1L, lA
                                      \
                        '}}

Latest revision as of 20:53, 29 October 2019

Forwards Re Ginna Nuclear Power Plant,Seismic Upgrading Program Piping Stress Analysis,Main Steam Sys,Section 200. Minor Design Changes or Const Mods Will Generally Not Affect Stress Results & Support Recommendations
ML17250A587
Person / Time
Site: Ginna Constellation icon.png
Issue date: 07/18/1980
From: Noon F
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To: Lilley M
ROCHESTER GAS & ELECTRIC CORP.
Shared Package
ML17250A588 List:
References
RGE-80-95, ST-SST-108, NUDOCS 8009170298
Download: ML17250A587 (3)


Text

I IIestinghoose Nater Reactor Nuclear Technology Oivision Electric Corporation Divisions Box 355 Pittsburgh Pennsylvania 15230 July 18, 1980 ST-SST- 108 RGE 95 Mr. M. P. Li lley

. Rochester Gas 8 Electric J9 East Avenue Rochester, Hew York 14649

Dear Mr. Li lley:

ROBERT EMMETT GINHA NUCLEAR GENERATING STATION R, E. Ginna Seismic Upgrading Program Main Steam Stress Re ort Transmitted herein is the piping stress report for the'R. E. Ginna Nuclear Generating Station Unit No. 1 Main Steam System, Section 200, SDTAR-80-05-'08..

Analysis results and support loads contained herein reflect the layout arrangement shown on marked isometric C-381-350, Sheet 1, Revision C. Any significant modifications to the layout of this system of piping and or

'y its restraints will warrant reanalysis of this piping system.

Minor design changes or construe.ion modifications will generally not affect stress results 'and suppor t recottrtendations. However, case by case review of the discrepancies can be used to determine overall system behavior and effects.

If any questions exist relative to the abo've transmittal, please contact W. A. Massie of Westinghouse.

truly yours, F. Noon, Manager Eastern Region WNI Support W. A. Massie/dj Attachment

M. P. Li 1 ley ~

+ATE-gO-5 cc: R. E. Smith - 'lL, 1A R. C. McCredy, RGE - 1L, M. P. Lilley, t<GE - 1L, lA T. R. Hei s, RGE<- 1L B. H. Bell, GA? -'1 L', lA P. N. Cameron, GAI - 1L, lA B. A. Snow, RGE - 1L J. C. Hutton, RGB,

, 1L, lA

\

'