| issue date = 08/16/1999
| issue date = 08/16/1999
| title = Forwards LER 99-019-00,re Victoreen Containment High Range Monitors Not Beign Environmentally Qualified to Withstand post-LOCA Conditions.Commitments Made by Util Are Listed
| title = Forwards LER 99-019-00,re Victoreen Containment High Range Monitors Not Beign Environmentally Qualified to Withstand post-LOCA Conditions.Commitments Made by Util Are Listed
| author name = RENCHECK M W
| author name = Rencheck M
| author affiliation = AMERICAN ELECTRIC POWER CO., INC.
| author affiliation = AMERICAN ELECTRIC POWER CO., INC.
| addressee name =  
| addressee name =  
Line 17: Line 17:


=Text=
=Text=
{{#Wiki_filter:~C~~EGORY%REGULATORY INFORMATION D1STRIBUTZON SYSTEM(RIDS)ACCESSION NBR:9908240283 DOC.DATE:
{{#Wiki_filter:~         C~~EGORY               %
99/08/16NOTARIZED:
REGULATORY INFORMATION D1STRIBUTZON SYSTEM (RIDS)
NODOCKET¹FACIL:50-315 DonaldC.CookNuclearPowerPlant,Unit1,IndianaM05000315AUTH.ÃAME
ACCESSION NBR:9908240283           DOC.DATE: 99/08/16        NOTARIZED: NO              DOCKET  ¹ FACIL:50-315 Donald C. Cook Nuclear Power Plant, Unit 1, Indiana M                      05000315 AUTH.ÃAME   ~         AUTHOR AFFILIATION RENCHECK,M.W.         American Electri'c Power Co., Znc.
~AUTHORAFFILIATION RENCHECK,M.W.
RECIP . NAME          RECZPXENT AFFILIATION Records Management Branch (Document Control Desk)
AmericanElectri'c PowerCo.,Znc.RECIP.NAMERECZPXENT AFFILIATION RecordsManagement Branch(Document ControlDesk)


==SUBJECT:==
==SUBJECT:==
ForwardsLER99-019-00,re victoreen containment highrangemontorsnotbeingenvironmentally qualified towithstand Post-LOCA conditions.
Forwards LER        99-019-00,re victoreen containment high range montors not being environmentally            qualified to withstand Post-LOCA conditions. Commitments made by util are listed.
Commitments madebyutilarelisted.D?BTRIBUTIQN cQDE:IE22TcoPIEsRECEIVED:LTR IENcjisIzE:+4TITLE:50.73/50.9 LicenseeEventReport(LER),IncidentRpt,etc.NOTES:LPRECIPIENT IDCODE/NAME COPIESLTTRENCL11RECIPIENT IDCODE/NAME STANG,JCOPIESLTTRENCL110INTERN:FILECENTER~R2X&PRE~RES/DET/ERAB RGN3PILE0111111111NRR/DIPM/IOLB NRR/DSSA/SPLB RES/DRAA/OERAB 111111EXTERNAL:
D?BTRIBUTIQN cQDE: IE22T coPIEs RECEIVED:LTR I ENcj i                      sIzE:       +4 TITLE: 50.73/50.9 Licensee Event Report (LER), Incident Rpt, etc.
LSTLOBBYWARDNOACPOORE,W.NRCPDR111111LMZTCOMARSHALLNOACQUEENER,DS NUDOCSFULLTXT111111DNNOTETOALL"RZDS"RECIPZENTS:
NOTES:
PLEASEHELPUSTOREDUCEWASTE.TOHAVEYOURNAMEORORGANIZATION REMOVEDFROMDISTRIBUTION LISTSORREDUCETHENUMBEROFCOPIESRECEIVEDBYYOUORYOURORGANIZATION, CONTACTTHEDOCUMENTCONTROLDESK(DCD)ONEXTENSION 415-2083FULLTEXTCONVERSION REQUIREDTOTALNUMBEROFCOPIESREQUIRED:
RECIPIENT        COPIES              RECIPIENT            COPIES ID CODE/NAME         LTTR ENCL          ID  CODE/NAME         LTTR ENCL LP                        1    1      STANG, J                  1      1              0 INTERN: FILE        CENTER            1    1      NRR/DIPM/IOLB            1      1
LTTR15ENCL15 American8eowerCookNuclearP1anrOneCookPlaceBridgman.
              ~R2X &PRE   ~
Ml491066164655901 ANERICANELECTRICPOWliRAugust16,1999UnitedStatesNuclearRegulatory Commission DocumentControlDeskWashington, DC20555Operating LicenseDPR-58DocketNo.50-315Document.
1    1      NRR/DSSA/SPLB            1      1 RES/DET/ERAB             1    1      RES/DRAA/OERAB           1    1 RGN3      PILE    01      1    1 EXTERNAL: L ST LOBBY WARD            1      1      LMZTCO MARSHALL          1    1 NOAC POORE,W.           1      1      NOAC QUEENER,DS           1    1 NRC PDR                  1      1      NUDOCS FULL TXT          1    1 D
ControlManager:Inaccordance withthecriteriaestablished by10CFR50.73entitledLicenseeEventReortSstemthefollowing reportisbeingsubmitted:
N NOTE TO ALL "RZDS" RECIPZENTS:
LER315/99-019-00, "Victoreen Containment HighRangeRadiation MonitorsNotEnvironmentally Qualified toWithstand Post-LOCA Conditions."
PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD) ON EXTENSION 415-2083 FULL TEXT CONVERSION REQUIRED TOTAL NUMBER OF COPIES REQUIRED: LTTR              15  ENCL    15
Thefollowing newcommitments wereidentified inthisLER.Apermanent solutionforthesusceptibility oftheHRRMstomoistureintrusion willbedeveloped tosupportHRRMoperability inModes1'-4.Optionsforthepermanent solutionarecurrently underreviewandwillbeimplemented priortoMode4foreachunit.Anevaluation oftheas-builtconfiguration forotherlowsignalcurrentapplication EQequipment isbeingperformed toidentifyadditional electrical equipment thatmaybesusceptible tomoistureintrusion duetoaLOCAorpipebreakcondition.
 
Theevaluation willincludeareviewofthecurrentEQProgramdocumentation regarding requirements forleaktight electrical enclosures.
American 8e        ower Cook Nuclear P1anr One Cook Place Bridgman. Ml 49106 6164655901 ANERICAN ELECTRIC POWliR August 16, 1999 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Operating License DPR-58 Docket No. 50-315 Document. Control Manager:
Thisevaluation willbe'ompleted bySeptember 30,1999.Basedonresultsoftheevaluation, appropriate corrective actionswillbetakentoaddressanyidentified EQdiscrepancies.
In accordance with the criteria established by 10 CFR 50.73 entitled Licensee Event Re ort S stem the following report is being submitted:
Sincerely, 4A~~M.W.RencheckVicePresident
LER 315/99-019-00, "Victoreen Containment High Range Radiation Monitors Not Environmentally Qualified to Withstand Post-LOCA Conditions."
-NuclearEngineering
The following new commitments were identified in this LER.
/bwoAttachment 9'F08240283
A permanent solution for the susceptibility of the HRRMs to moisture intrusion will be developed to support HRRM operability in Modes 1'-4. Options for the permanent solution are currently under review and will be implemented prior to Mode 4 for each unit.
'rr908fhPDRADQCK05000315SPDR J.E.Dyer,RegionIIIR.P.PowersP.A.BarrettR.C.GodleyR.WhaleD.HahnRecordsCenter,INPONRCResidentInspector}}
An evaluation of the as-built configuration for other low signal current application EQ equipment is being performed to identify additional electrical equipment that may be susceptible to moisture intrusion due to a LOCA or pipe break condition.
The evaluation will include a review of the current EQ Program documentation regarding requirements for leaktight electrical enclosures. This evaluation will be by September 30, 1999. Based on results of the evaluation, appropriate'ompleted corrective actions will be taken to address any identified EQ discrepancies.
Sincerely, 4A M. W. Rencheck
                    ~~
Vice President Nuclear Engineering
      /bwo Attachment 9'F08240283 'rr908fh PDR    ADQCK 05000315 S                          PDR
 
J. E. Dyer, Region III R. P. Powers P. A. Barrett R. C. Godley R. Whale D. Hahn Records Center, INPO NRC Resident Inspector}}

Latest revision as of 06:32, 29 October 2019

Forwards LER 99-019-00,re Victoreen Containment High Range Monitors Not Beign Environmentally Qualified to Withstand post-LOCA Conditions.Commitments Made by Util Are Listed
ML17326A089
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 08/16/1999
From: Rencheck M
AMERICAN ELECTRIC POWER CO., INC.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML17326A090 List:
References
NUDOCS 9908240283
Download: ML17326A089 (3)


Text

~ C~~EGORY  %

REGULATORY INFORMATION D1STRIBUTZON SYSTEM (RIDS)

ACCESSION NBR:9908240283 DOC.DATE: 99/08/16 NOTARIZED: NO DOCKET ¹ FACIL:50-315 Donald C. Cook Nuclear Power Plant, Unit 1, Indiana M 05000315 AUTH.ÃAME ~ AUTHOR AFFILIATION RENCHECK,M.W. American Electri'c Power Co., Znc.

RECIP . NAME RECZPXENT AFFILIATION Records Management Branch (Document Control Desk)

SUBJECT:

Forwards LER 99-019-00,re victoreen containment high range montors not being environmentally qualified to withstand Post-LOCA conditions. Commitments made by util are listed.

D?BTRIBUTIQN cQDE: IE22T coPIEs RECEIVED:LTR I ENcj i sIzE: +4 TITLE: 50.73/50.9 Licensee Event Report (LER), Incident Rpt, etc.

NOTES:

RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL LP 1 1 STANG, J 1 1 0 INTERN: FILE CENTER 1 1 NRR/DIPM/IOLB 1 1

~R2X &PRE ~

1 1 NRR/DSSA/SPLB 1 1 RES/DET/ERAB 1 1 RES/DRAA/OERAB 1 1 RGN3 PILE 01 1 1 EXTERNAL: L ST LOBBY WARD 1 1 LMZTCO MARSHALL 1 1 NOAC POORE,W. 1 1 NOAC QUEENER,DS 1 1 NRC PDR 1 1 NUDOCS FULL TXT 1 1 D

N NOTE TO ALL "RZDS" RECIPZENTS:

PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD) ON EXTENSION 415-2083 FULL TEXT CONVERSION REQUIRED TOTAL NUMBER OF COPIES REQUIRED: LTTR 15 ENCL 15

American 8e ower Cook Nuclear P1anr One Cook Place Bridgman. Ml 49106 6164655901 ANERICAN ELECTRIC POWliR August 16, 1999 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Operating License DPR-58 Docket No. 50-315 Document. Control Manager:

In accordance with the criteria established by 10 CFR 50.73 entitled Licensee Event Re ort S stem the following report is being submitted:

LER 315/99-019-00, "Victoreen Containment High Range Radiation Monitors Not Environmentally Qualified to Withstand Post-LOCA Conditions."

The following new commitments were identified in this LER.

A permanent solution for the susceptibility of the HRRMs to moisture intrusion will be developed to support HRRM operability in Modes 1'-4. Options for the permanent solution are currently under review and will be implemented prior to Mode 4 for each unit.

An evaluation of the as-built configuration for other low signal current application EQ equipment is being performed to identify additional electrical equipment that may be susceptible to moisture intrusion due to a LOCA or pipe break condition.

The evaluation will include a review of the current EQ Program documentation regarding requirements for leaktight electrical enclosures. This evaluation will be by September 30, 1999. Based on results of the evaluation, appropriate'ompleted corrective actions will be taken to address any identified EQ discrepancies.

Sincerely, 4A M. W. Rencheck

~~

Vice President Nuclear Engineering

/bwo Attachment 9'F08240283 'rr908fh PDR ADQCK 05000315 S PDR

J. E. Dyer, Region III R. P. Powers P. A. Barrett R. C. Godley R. Whale D. Hahn Records Center, INPO NRC Resident Inspector