| title = Haddam Neck Plant, Final Status Survey Final Report Phase Iv, Appendix A1 Survey Unit Release Record 9106-0001, Discharge Canal
| title = Final Status Survey Final Report Phase IV, Appendix A1 Survey Unit Release Record 9106-0001, Discharge Canal
| author name = Newson C
| author name = Newson C
| author affiliation = Connecticut Yankee Atomic Power Co
| author affiliation = Connecticut Yankee Atomic Power Co
Line 59: Line 59:
17 mrem/yrso 1 l+2 mrem/yrExisting GW+O mrem/yrFuture GW The allowable dose for soil in this survey unit is seventeen (17) mrem/yr TEDE as shown by Equation 2 above. The concentration of residual radioactivity resulting in seventeen (17) mrem/yr TEDE is designated as the Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2.Note: The survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 to conservatively account for the contribution to the total dose from existing and future groundwater which had not been established at the time of planning the FSS.Revision 0 7 Revision 0 7 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD C-14 5.66E+00 3.85E+00 2.26E-01 Mn-54 1.74E+01 1. 18E+01 6.96E-0I Fe-55 2.74E+04 1.86E+04 1.1OE+03 Co-60 3.81E+00 2.59E+00 1.52E-01 Ni-63 7.23E+02 4.92E+02 2.89E+O1 Sr-90 1.55E+00 1.05E+00 6.20E-02 Nb-94 7.12E+00 4.84E+00 2.85E-01 Tc-99 1.26E+O1 8.57E+00 5.04E-0I Ag- 108m 7.14E+00 4.86E+00 2.86E-01 Cs-134 4.67E+00 3.18E+00 1.87E-01 Cs-137 7.91E+00 5.38E+00 3.16E-01 Eu-152 1.01E+01 6.87E+00 4.04E-01 Eu- 154 9.29E+00 6.32E+00 3.72E-01 Eu-155 3.92E+02 2.67E+02 1.57E+01 Pu-238 2.96E+O1 2.01 E+O1 1.18E+00 Pu-239/240 2.67E+0 1 1.82E+01 1.07E+00 Pu-241 8.70E+02 5.92E+02 3.48E+01 Am-241 (5) 2.58E+0I 1.75E+01 1.03E+00 Cm-243/244 2.90E+0 I 1.97E+0 1 1.16E+00 (1) Bold indicates those radionuclides considered to be Hard to Detect (HTD).(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to twenty-five (25) mrem/yr TEDE.(3) The Operational DCGL is equivalent to seventeen (17) mrem/yr TEDE.(4) The required MDC is equivalent to one (1) mrem/yr TEDE.(5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopy's when both analyses are performed.
17 mrem/yrso 1 l+2 mrem/yrExisting GW+O mrem/yrFuture GW The allowable dose for soil in this survey unit is seventeen (17) mrem/yr TEDE as shown by Equation 2 above. The concentration of residual radioactivity resulting in seventeen (17) mrem/yr TEDE is designated as the Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2.Note: The survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 to conservatively account for the contribution to the total dose from existing and future groundwater which had not been established at the time of planning the FSS.Revision 0 7 Revision 0 7 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD C-14 5.66E+00 3.85E+00 2.26E-01 Mn-54 1.74E+01 1. 18E+01 6.96E-0I Fe-55 2.74E+04 1.86E+04 1.1OE+03 Co-60 3.81E+00 2.59E+00 1.52E-01 Ni-63 7.23E+02 4.92E+02 2.89E+O1 Sr-90 1.55E+00 1.05E+00 6.20E-02 Nb-94 7.12E+00 4.84E+00 2.85E-01 Tc-99 1.26E+O1 8.57E+00 5.04E-0I Ag- 108m 7.14E+00 4.86E+00 2.86E-01 Cs-134 4.67E+00 3.18E+00 1.87E-01 Cs-137 7.91E+00 5.38E+00 3.16E-01 Eu-152 1.01E+01 6.87E+00 4.04E-01 Eu- 154 9.29E+00 6.32E+00 3.72E-01 Eu-155 3.92E+02 2.67E+02 1.57E+01 Pu-238 2.96E+O1 2.01 E+O1 1.18E+00 Pu-239/240 2.67E+0 1 1.82E+01 1.07E+00 Pu-241 8.70E+02 5.92E+02 3.48E+01 Am-241 (5) 2.58E+0I 1.75E+01 1.03E+00 Cm-243/244 2.90E+0 I 1.97E+0 1 1.16E+00 (1) Bold indicates those radionuclides considered to be Hard to Detect (HTD).(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to twenty-five (25) mrem/yr TEDE.(3) The Operational DCGL is equivalent to seventeen (17) mrem/yr TEDE.(4) The required MDC is equivalent to one (1) mrem/yr TEDE.(5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopy's when both analyses are performed.
Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability.
Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability.
Initial characterization was performed in April and May of 2004 and final characterization in May of 2006 as discussed in Section 2. Cs-137 and Co-60 were found to be the predominate radionuclides of concern. The basic statistical quantities (i.e., mean, standard deviation, median) for Cs- 137 and Co-60 are provided in Table 1.As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Detectable Concentration  
Initial characterization was performed in April and May of 2004 and final characterization in May of 2006 as discussed in Section 2. Cs-137 and Co-60 were found to be the predominate radionuclides of concern. The basic statistical quantities (i.e., mean, standard deviation, median) for Cs- 137 and Co-60 are provided in Table 1.As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Detectable Concentration
(<MDC) were not accepted for FSS. Sample report Revision 0 8 Revision 0 8 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD summaries included unique sample identification, analytical method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.The Elevated Measurement Comparison (EMC) consists of comparing each measurement from the survey unit with the investigation levels discussed in Section 4.0 (and presented in Table 4). As stated in section 5.8.3 of the LTP, any measurement from the survey unit that is greater than an investigation level indicates an area of relatively high concentrations that should be investigated, regardless of the outcome of the nonparametric statistical tests. Thus the use of the EMC against the investigation levels may be viewed as assurance that unusually large measurements will receive proper attention regardless of the outcome of those tests and that any area having the potential for significant dose contributions will be identified.
(<MDC) were not accepted for FSS. Sample report Revision 0 8 Revision 0 8 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD summaries included unique sample identification, analytical method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.The Elevated Measurement Comparison (EMC) consists of comparing each measurement from the survey unit with the investigation levels discussed in Section 4.0 (and presented in Table 4). As stated in section 5.8.3 of the LTP, any measurement from the survey unit that is greater than an investigation level indicates an area of relatively high concentrations that should be investigated, regardless of the outcome of the nonparametric statistical tests. Thus the use of the EMC against the investigation levels may be viewed as assurance that unusually large measurements will receive proper attention regardless of the outcome of those tests and that any area having the potential for significant dose contributions will be identified.
The LTP (by way of Equation 5-31) states that if elevated levels of residual radioactivity are present over portions of the survey unit area, they will be evaluated in conjunction with the average level of residual activity present across the balance of the survey unit to determine whether the total dose associated with the distribution of activity present is in compliance with the release criteria.
The LTP (by way of Equation 5-31) states that if elevated levels of residual radioactivity are present over portions of the survey unit area, they will be evaluated in conjunction with the average level of residual activity present across the balance of the survey unit to determine whether the total dose associated with the distribution of activity present is in compliance with the release criteria.
Line 154: Line 154:
--45709 R-158 9904 68-485 W South Carolina 10120001/10585001/10120002 Tennessee 02934 Texas TX213-2006A U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8 8037697376 GEL Vermont Virginia N/A 00151 Washington C223 5 Chain of Custody And Supporting Documentation 6
--45709 R-158 9904 68-485 W South Carolina 10120001/10585001/10120002 Tennessee 02934 Texas TX213-2006A U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8 8037697376 GEL Vermont Virginia N/A 00151 Washington C223 5 Chain of Custody And Supporting Documentation 6
Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-00 1 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00516 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:
Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-00 1 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00516 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:
E] 30 D. [ 14 D. 7 D. l 3 D. Container Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Lab Sample ID Code Code Code 9106-0001-127F 8/1/06 13:59 SE C BP X Transferred from COC 2006-00480 9106-0001-128F 8/1/06 12:58 SE C BP x Transferred from COC 2006-00480 9106-0001-129F 8/7/06 08:06 SE C BP X Transferred from COC 2006-00487 9106-0001-130F 8/1/06 11:10 SE C BP X Transferred from COC 2006-00480 9106-0001-131F 8/7/06 13:32 SE C BP X Transferred from COC 2006-00487 9106-0001-133F 8/8/06 13:35 SE C BP X Transferred from COC 2006-00488 9106-0001-117F 8/3/06 12:55 SE C BP X Transferred from COC 2006-00484 9106-0001-117FS 8/3/06 12:55 SE C BP X Transferred from COC 2006-00484 NOTES: PO #: 002332 MSR #: 06-/576 SSWP# NA Z LTP QA E] Radwaste QA LI Non QA Samples Shipped Via: Internal Container Z Fed Ex Temp.: __ Deg.LIUPS C LI Hand Custody Sealed?Y L NE0 1) Relinquished By Datg/Time  
E] 30 D. [ 14 D. 7 D. l 3 D. Container Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Lab Sample ID Code Code Code 9106-0001-127F 8/1/06 13:59 SE C BP X Transferred from COC 2006-00480 9106-0001-128F 8/1/06 12:58 SE C BP x Transferred from COC 2006-00480 9106-0001-129F 8/7/06 08:06 SE C BP X Transferred from COC 2006-00487 9106-0001-130F 8/1/06 11:10 SE C BP X Transferred from COC 2006-00480 9106-0001-131F 8/7/06 13:32 SE C BP X Transferred from COC 2006-00487 9106-0001-133F 8/8/06 13:35 SE C BP X Transferred from COC 2006-00488 9106-0001-117F 8/3/06 12:55 SE C BP X Transferred from COC 2006-00484 9106-0001-117FS 8/3/06 12:55 SE C BP X Transferred from COC 2006-00484 NOTES: PO #: 002332 MSR #: 06-/576 SSWP# NA Z LTP QA E] Radwaste QA LI Non QA Samples Shipped Via: Internal Container Z Fed Ex Temp.: __ Deg.LIUPS C LI Hand Custody Sealed?Y L NE0 1) Relinquished By Datg/Time
: 2) R ed By Date/Time Custody Seal jeymf &-J4_-;Jr OherIntact?
: 2) R ed By Date/Time Custody Seal jeymf &-J4_-;Jr OherIntact?
: 3) Relinquished By bate/Time 4)3&*ived By > Date/TIime BillofLading
: 3) Relinquished By bate/Time 4)3&*ived By > Date/TIime BillofLading
_Y Y N 0 Bill of Lading #5) Relinquished By Date/Time  
_Y Y N 0 Bill of Lading #5) Relinquished By Date/Time
: 6) Received By Date/Time -c9o" 37 7",?18 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major 0 Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00517 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Iaddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:  
: 6) Received By Date/Time -c9o" 37 7",?18 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major 0 Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00517 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Iaddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:
[] 30 D. E] 14 D. Z 7 D. E] 3 D. r Container Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Lab Sample ID Code Code Code 9106-0001-113F 8/3/06 08:12 SE C BP X Transferred from COC 2006-00484 9106-0001-114F 8/3/06 08:38 SE C BP X Transferred from COC 2006-00484 9106-0001-116F 8/3/06 10:04 SE C BP x Transferred from COC 2006-00484 9106-0001-120F 8/3/06 14:06 SE C BP X Transferred from COC 2006-00484 9106-0001-121F 8/3/06 14:32 SE C BP x Transferred from COC 2006-00484 9106-0001-104F 8/8/06 10:28 SE C BP X Transferred from COC 2006-00488 9106-0001-107F 8/8/06 08:59 SE C BP X Transferred from COC 2006-00484 9106-0001-115F 8/8/06 08:14 SE C BP X Transferred from COC 2006-00484 NOTES: PO #: 002332 MSR #: 06-1156 SSWP# NA Z LTP QA El Radwaste QA El Non QA Samples Shipped Via: Internal Container 0 Fed Ex Temp.: __ Deg.El ups C El Hand Custody Sealed?YB0 NE 1) Relinquished By Date/Time  
[] 30 D. E] 14 D. Z 7 D. E] 3 D. r Container Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Lab Sample ID Code Code Code 9106-0001-113F 8/3/06 08:12 SE C BP X Transferred from COC 2006-00484 9106-0001-114F 8/3/06 08:38 SE C BP X Transferred from COC 2006-00484 9106-0001-116F 8/3/06 10:04 SE C BP x Transferred from COC 2006-00484 9106-0001-120F 8/3/06 14:06 SE C BP X Transferred from COC 2006-00484 9106-0001-121F 8/3/06 14:32 SE C BP x Transferred from COC 2006-00484 9106-0001-104F 8/8/06 10:28 SE C BP X Transferred from COC 2006-00488 9106-0001-107F 8/8/06 08:59 SE C BP X Transferred from COC 2006-00484 9106-0001-115F 8/8/06 08:14 SE C BP X Transferred from COC 2006-00484 NOTES: PO #: 002332 MSR #: 06-1156 SSWP# NA Z LTP QA El Radwaste QA El Non QA Samples Shipped Via: Internal Container 0 Fed Ex Temp.: __ Deg.El ups C El Hand Custody Sealed?YB0 NE 1) Relinquished By Date/Time
: 2) Rece ed By Date ime Custody Seal 35OIm[ 9,A~'-L3-06,11340 OhrIntact?
: 2) Rece ed By Date ime Custody Seal 35OIm[ 9,A~'-L3-06,11340 OhrIntact?
3 ) R e lin q u ish ed B y D a te/T im e 4 dR -B y _"_-_ __at e/_ _im eY B N B Bill of Lading 4 5) Relinquished By Date/Time  
3 ) R e lin q u ish ed B y D a te/T im e 4 dR -B y _"_-_ __at e/_ _im eY B N B Bill of Lading 4 5) Relinquished By Date/Time
: 6) Received By Date/Time Ho. .3 3 ,4Z/q Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Chain of Custody Form No. 2006-00518 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones o Priority:
: 6) Received By Date/Time Ho. .3 3 ,4Z/q Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Chain of Custody Form No. 2006-00518 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones o Priority:
F] 30 D. [] 14 D. Z 7 D. E] 3 D.Container Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Lab Sample ID Code Code Code 9106-0001-108F 8/7/06 14:42 SE C BP X Transferred from COC 2006-00487 9106-0001-119F 8/7/06 11:01 SE C BP X Transferred from COC 2006-00487 9106-0001-IO1F 7/31/06 13:25 SE C BP X Transferred from COC 2006-00478 9106-0001-103F 7/31/06 15:00 SE C BP x Transferred from COC 2006-00478 9106-0001-106F 8/2/06 08:00 SE C BP X Transferred from COC 2006-00484 9106-0001-106FS 8/2/06 08:00 SE C BP x Transferred from COC 2006-00488 9106-0001-11 OF 8/2/06 10:20 SE C BP X Transferred from COC 2006-00482 NOTES: PO #: 002332 MSR #: 06-115_6 SSWP# NA [ LTP QA [I Radwaste QA [ Non QA Samples Shipped Via: Internal Container Z Fed Ex Temp.: __ Deg.EZUPS C E] Hand Custody Sealed?yE I Relinquished By Date/Time  
F] 30 D. [] 14 D. Z 7 D. E] 3 D.Container Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Lab Sample ID Code Code Code 9106-0001-108F 8/7/06 14:42 SE C BP X Transferred from COC 2006-00487 9106-0001-119F 8/7/06 11:01 SE C BP X Transferred from COC 2006-00487 9106-0001-IO1F 7/31/06 13:25 SE C BP X Transferred from COC 2006-00478 9106-0001-103F 7/31/06 15:00 SE C BP x Transferred from COC 2006-00478 9106-0001-106F 8/2/06 08:00 SE C BP X Transferred from COC 2006-00484 9106-0001-106FS 8/2/06 08:00 SE C BP x Transferred from COC 2006-00488 9106-0001-11 OF 8/2/06 10:20 SE C BP X Transferred from COC 2006-00482 NOTES: PO #: 002332 MSR #: 06-115_6 SSWP# NA [ LTP QA [I Radwaste QA [ Non QA Samples Shipped Via: Internal Container Z Fed Ex Temp.: __ Deg.EZUPS C E] Hand Custody Sealed?yE I Relinquished By Date/Time
: 2) ReceivA By Dat /Time Custody Seal lame 9-z7-O /913+0 77I, .Other Intact?3) Relinquished By Date/Time  
: 2) ReceivA By Dat /Time Custody Seal lame 9-z7-O /913+0 77I, .Other Intact?3) Relinquished By Date/Time
: 4) k ed By Bl of La-dingt Y Y N El Bill of Lading #5) Relinquished By Date/Time  
: 4) k ed By Bl of La-dingt Y Y N El Bill of Lading #5) Relinquished By Date/Time
: 6) Received By Date/Time 3 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 1 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00519 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Ln Priority:
: 6) Received By Date/Time 3 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 1 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00519 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Ln Priority:
EJ 30 D. [] 14 D. 0 7 D.E] 3 D.Container Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Lab Sample ID C ode C od e C ode _004 82 9106-0001-109F 8/2/06 09:37 SE C BP X Transferred from COC 2006-00482 9106-0001-11 IF 8/2/06 13:23 SE C BP X Transferred from COC 2006-00482 9106-0001-122F 8/4/06 07:55 SE C BP X Transferred from COC 2006-00485 9106-0001-123F 8/4/06 09:45 SE C BP X Transferred from COC 2006-00485 9106-0001-124F 8/4/06 11:18 SE C BP X Transferred from COC 2006-00485 9106-0001-125F 8/4/06 12:54 SE C BP X Transferred from COC 2006-00485 9106-0001-126F 8/4/06 13:39 SE C BP X Transferred from COC 2006-00485 NOTES: PO #: 002332 MSR #: 06-115-6 SSWP# NA Z LTP QA [1 Radwaste QA LJ Non QA Samples Shipped Via: Internal Container Z Fed Ex Temp.: _ Deg.U UPS C E] Hand Custody Sealed?__ _ _ _ _ _ __ _ _ _ _ _ _YFI N[]1) Relinquished By Date/Time  
EJ 30 D. [] 14 D. 0 7 D.E] 3 D.Container Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Lab Sample ID C ode C od e C ode _004 82 9106-0001-109F 8/2/06 09:37 SE C BP X Transferred from COC 2006-00482 9106-0001-11 IF 8/2/06 13:23 SE C BP X Transferred from COC 2006-00482 9106-0001-122F 8/4/06 07:55 SE C BP X Transferred from COC 2006-00485 9106-0001-123F 8/4/06 09:45 SE C BP X Transferred from COC 2006-00485 9106-0001-124F 8/4/06 11:18 SE C BP X Transferred from COC 2006-00485 9106-0001-125F 8/4/06 12:54 SE C BP X Transferred from COC 2006-00485 9106-0001-126F 8/4/06 13:39 SE C BP X Transferred from COC 2006-00485 NOTES: PO #: 002332 MSR #: 06-115-6 SSWP# NA Z LTP QA [1 Radwaste QA LJ Non QA Samples Shipped Via: Internal Container Z Fed Ex Temp.: _ Deg.U UPS C E] Hand Custody Sealed?__ _ _ _ _ _ __ _ _ _ _ _ _YFI N[]1) Relinquished By Date/Time
: 2) Receii d By .DatiTime Custody Seal-Other Intact?3) Relinquished By Date/Time  
: 2) Receii d By .DatiTime Custody Seal-Other Intact?3) Relinquished By Date/Time
: 4) k By -ateimeBillofLadin Y f N [Bill of Lading #5) Relinquished By Date/Time  
: 4) k By -ateimeBillofLadin Y f N [Bill of Lading #5) Relinquished By Date/Time
: 6) Received By Date/Time 79o 3 71 22 / 0 Connecticut Yankee Statement of Work for Analytical Lab Services .CY-ISC-SOW-OOl Figure 1. Sample Check-in List Date/Time Received: Work Order Number: -0 I -Shipping Container ID:Q .'. /RAI Chain of Custody #  I. Custody Seals o6 shipping container intact? Yes, --No [ I 2. Custody Seals dated and signed? Yes [fNo 3. Chain-of-Custody record present? Yes [,jl"o [ ]4. Cooler temperature
: 6) Received By Date/Time 79o 3 71 22 / 0 Connecticut Yankee Statement of Work for Analytical Lab Services .CY-ISC-SOW-OOl Figure 1. Sample Check-in List Date/Time Received: Work Order Number: -0 I -Shipping Container ID:Q .'. /RAI Chain of Custody #  I. Custody Seals o6 shipping container intact? Yes, --No [ I 2. Custody Seals dated and signed? Yes [fNo 3. Chain-of-Custody record present? Yes [,jl"o [ ]4. Cooler temperature
: 5. Vermiculite/packing materials is: Wet [q ',y []6: Number of samples in shipping container:
: 5. Vermiculite/packing materials is: Wet [q ',y []6: Number of samples in shipping container:
Line 186: Line 186:
'7. Sample holding times exceeded?
'7. Sample holding times exceeded?
Yes [ j.8. Samples have:------tat...._.hazard labels--/-custody Seals -appropriate sample labels 9. Samples are: good condition  
Yes [ j.8. Samples have:------tat...._.hazard labels--/-custody Seals -appropriate sample labels 9. Samples are: good condition  
.-*.leaking-broken -have air bubbles 10. Were any anomalies identified in sample receipt? Yes [ No 1. .Description of anomalies (include sample numbers): Sample Cstodian/Lahoratory:  
.-*.leaking-broken -have air bubbles 10. Were any anomalies identified in sample receipt? Yes [ No 1. .Description of anomalies (include sample numbers): Sample Cstodian/Lahoratory:
:: ." Telephoned to: On By.. : " .... By.13 Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-OOI Figure 1. Sample Check-in List Date/Time Received: SDG#:-Work Order Number: Fl " \ " Shipping Cdntainer ID, 7 )"- 7 2"/ Q Chain of a-.-S/-1. Custody Seals oni shipping container intact?..
:: ." Telephoned to: On By.. : " .... By.13 Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-OOI Figure 1. Sample Check-in List Date/Time Received: SDG#:-Work Order Number: Fl " \ " Shipping Cdntainer ID, 7 )"- 7 2"/ Q Chain of a-.-S/-1. Custody Seals oni shipping container intact?..
Yes t o[']o 2. Custody Seals dated and signed? Yes'p.No [ ,.3. Chain-of-Custody record present? Yes K" No [ ].4. Cooler temperature ."" 5. Vermiculite/packing materials is: Wet [.-br ]6.' Number of samples in shipping container:__'
Yes t o[']o 2. Custody Seals dated and signed? Yes'p.No [ ,.3. Chain-of-Custody record present? Yes K" No [ ].4. Cooler temperature ."" 5. Vermiculite/packing materials is: Wet [.-br ]6.' Number of samples in shipping container:__'
: 7. Sample holding times exceeded?
: 7. Sample holding times exceeded?
Yes 8. Samples have:'' Ztape ....hazard labels_... custody seals -appropriate sample labels 9. Samples are:*i good condition -leaking broken ." have air bubbles 10. Were any anomalies identified in sample receipt? Yes [] No 11.. .Description of anomalies,(include sample numbers): Telephoned to: On By .14 RADIOLOGICAL ANALYSIS 15 Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)Work Order 170132 Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 562551 562335 562334 Sample ID 170132002 1201169377 1201169378 1201169379 1201169380 Client ID 9106-0001-121F Method Blank (MB)170125005(9522-0006-ASPHALT-0  
Yes 8. Samples have:'' Ztape ....hazard labels_... custody seals -appropriate sample labels 9. Samples are:*i good condition -leaking broken ." have air bubbles 10. Were any anomalies identified in sample receipt? Yes [] No 11.. .Description of anomalies,(include sample numbers): Telephoned to: On By .14 RADIOLOGICAL ANALYSIS 15 Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)Work Order 170132 Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 562551 562335 562334 Sample ID 170132002 1201169377 1201169378 1201169379 1201169380 Client ID 9106-0001-121F Method Blank (MB)170125005(9522-0006-ASPHALT-0
: 15) Sample Duplicate (DUP)170125005(9522-0006-ASPHALT-O1  
: 15) Sample Duplicate (DUP)170125005(9522-0006-ASPHALT-O1
: 5) Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.Calibration Information:
: 5) Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Line 200: Line 200:
Miscellaneous Information:
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.
A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information 17 Product: Alphaspec Pu, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- 11-RC Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 562552 562335 562334 Sample ID 170132002 1201169381 1201169382 1201169383 1201169384 Client ID 9106-0001-121F Method Blank (MB)170125005(9522-0006-ASPHALT-0  
A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information 17 Product: Alphaspec Pu, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- 11-RC Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 562552 562335 562334 Sample ID 170132002 1201169381 1201169382 1201169383 1201169384 Client ID 9106-0001-121F Method Blank (MB)170125005(9522-0006-ASPHALT-0
: 15) Sample Duplicate (DUP)170125005(9522-0006-ASPHALT-015)
: 15) Sample Duplicate (DUP)170125005(9522-0006-ASPHALT-015)
Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-011 REV# 14.Calibration Information:
Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-011 REV# 14.Calibration Information:
Line 211: Line 211:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.
A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- 11-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 562553 Prep Batch Number: 562335 Dry Soil Prep GL-RAD-A-021 Batch Number: 562334 19 Sample ID Client ID 170132002 9106-0001-121F 1201169385 Method Blank (MB)1201169386 170125005(9522-0006-ASPHALT-015)
A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- 11-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 562553 Prep Batch Number: 562335 Dry Soil Prep GL-RAD-A-021 Batch Number: 562334 19 Sample ID Client ID 170132002 9106-0001-121F 1201169385 Method Blank (MB)1201169386 170125005(9522-0006-ASPHALT-015)
Sample Duplicate (DUP)1201169387 170125005(9522-0006-ASPHALT-0  
Sample Duplicate (DUP)1201169387 170125005(9522-0006-ASPHALT-0
: 15) Matrix Spike (MS)1201169388 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.Calibration Information:
: 15) Matrix Spike (MS)1201169388 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Line 448: Line 448:
Ej 14D. El-7D.Z3 D.Container Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation .I-.S., ID Code Code Code 9106-0001-132F SE C BP X 9106-0001-112F SE C BP X 9106-0001-132A SE C BP X ' .9106-0001-132B SE C BP X 9106-0001-132C SE C BP X 9106-0001-132D SE C BP X 9106-0001-1 12A SE C BP x 9106-0001-112B SE C BP X 9106-0001-112C SE C BP X NOTES: PO #: 002332 MSR #: 06- m3o0 SSWP# NA Z LTP QA 0 Radwaste QA E] Non QA Samples Shipped Via: 'Internal Container Z Fed Ex _Tern Dg C] Hand X. ustody'Sciled9
Ej 14D. El-7D.Z3 D.Container Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation .I-.S., ID Code Code Code 9106-0001-132F SE C BP X 9106-0001-112F SE C BP X 9106-0001-132A SE C BP X ' .9106-0001-132B SE C BP X 9106-0001-132C SE C BP X 9106-0001-132D SE C BP X 9106-0001-1 12A SE C BP x 9106-0001-112B SE C BP X 9106-0001-112C SE C BP X NOTES: PO #: 002332 MSR #: 06- m3o0 SSWP# NA Z LTP QA 0 Radwaste QA E] Non QA Samples Shipped Via: 'Internal Container Z Fed Ex _Tern Dg C] Hand X. ustody'Sciled9
: 1) Relinquished By Date ime 2) Received By D te/Time tu".0 "stody Seal .J'-IP 6RICAT C Jc2 0 j__ .QL e,. I/SI Other I_.ntac'&?
: 1) Relinquished By Date ime 2) Received By D te/Time tu".0 "stody Seal .J'-IP 6RICAT C Jc2 0 j__ .QL e,. I/SI Other I_.ntac'&?
: 3) Relinquished By Date/Time  
: 3) Relinquished By Date/Time
: 4) Received By Date/Time
: 4) Received By Date/Time
_.._ ? NO Bill of Lading #5) Relinquished By Date/Time  
_.._ ? NO Bill of Lading #5) Relinquished By Date/Time
: 6) Received By Date/Time  
: 6) Received By Date/Time
:79 ,_/ 8)30 3 0 -.
:79 ,_/ 8)30 3 0 -.
Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 oject Name: Haddam Neck Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones r~ ;?~ ~~r Priority:  
Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 oject Name: Haddam Neck Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones r~ ;?~ ~~r Priority:
[] 30 D. [] 14 D. ] 7 D. Z 3 D...... ... .. li" "" .. ........ ... .. .......... ..... ....,, , ,, -.....Sample Designation I Date Comment, Preservation I ID* Samples Shipped Via: Z Fed Ex El UPS El Hand Ml Other Bill of Lading #;q/ 91,70 3 4cZ Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-OO0 Figure 1. -Sample Check-in List Date/Time Received:
[] 30 D. [] 14 D. ] 7 D. Z 3 D...... ... .. li" "" .. ........ ... .. .......... ..... ....,, , ,, -.....Sample Designation I Date Comment, Preservation I ID* Samples Shipped Via: Z Fed Ex El UPS El Hand Ml Other Bill of Lading #;q/ 91,70 3 4cZ Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-OO0 Figure 1. -Sample Check-in List Date/Time Received:
91171040 SDG#: U /#(-/3 Work Order Number:/49 t8 Shipping Cdntainer ID: 7921 6130 ,,?Z. Chain of Custody # -P0 Vi9. '1. Custody Seals ori shipping container intact? *Yes t I No [W,"" 2. Custody Seals dated and signed? Yes [ ] No [1 3. Chain-of-Custody record present? Yes kl"No I ]4. Cooler temperature 2 " 5. Vermiculite/packing materials is: Wet ( TD 6. Number of samples in shipping container:  
91171040 SDG#: U /#(-/3 Work Order Number:/49 t8 Shipping Cdntainer ID: 7921 6130 ,,?Z. Chain of Custody # -P0 Vi9. '1. Custody Seals ori shipping container intact? *Yes t I No [W,"" 2. Custody Seals dated and signed? Yes [ ] No [1 3. Chain-of-Custody record present? Yes kl"No I ]4. Cooler temperature 2 " 5. Vermiculite/packing materials is: Wet ( TD 6. Number of samples in shipping container:  
Line 542: Line 542:
9106-0001-132B SE C BP X 9106-0001-132C SE C BP X ---___________
9106-0001-132B SE C BP X 9106-0001-132C SE C BP X ---___________
9106-0001-132D SE C BP X 9106-0001-112A SE C BP X 9106-0001-1 12B _____ SE C BP X 9106-0001-1 12C _________
9106-0001-132D SE C BP X 9106-0001-112A SE C BP X 9106-0001-1 12B _____ SE C BP X 9106-0001-1 12C _________
SE C BP X NOTES: PO #: 002332 MSR #: 06- t7Co SSWP# NA U LTP QA [ Radwaste QA [ Non QA Samples Shipped Via: ._In e onta~er[ Fed Ex Temp- De.LIUPS C E] Hand i &sect;aled?..1) Relinquished By Date/Time  
SE C BP X NOTES: PO #: 002332 MSR #: 06- t7Co SSWP# NA U LTP QA [ Radwaste QA [ Non QA Samples Shipped Via: ._In e onta~er[ Fed Ex Temp- De.LIUPS C E] Hand i &sect;aled?..1) Relinquished By Date/Time
: 2) Received By D ,te/Time Custody Seal JI310 -14~ -e 0-/6 /5 2 -.I]Other to/3) Relinquished By Date/Time  
: 2) Received By D ,te/Time Custody Seal JI310 -14~ -e 0-/6 /5 2 -.I]Other to/3) Relinquished By Date/Time
: 4) Received By Date/Time N-:.____________
: 4) Received By Date/Time N-:.____________
b Bill of Lading 5) Relinquished By Date/Time  
b Bill of Lading 5) Relinquished By Date/Time
: 6) Received By Date/Time  
: 6) Received By Date/Time
:7u/ Cl 0 Y)30 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00497 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested  
:7u/ Cl 0 Y)30 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00497 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested  
-Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State) .General Engineering Laboratories 2040 Savage Road, Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones oo Priority:
-Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State) .General Engineering Laboratories 2040 Savage Road, Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones oo Priority:
E'-30 DRE 14D.j I-7D. 0 3D.Container Sample Size- Comment, Preservation  
E'-30 DRE 14D.j I-7D. 0 3D.Container Sample Size- Comment, Preservation  
$ Laap t)Sample Designation Date Time Media Type &Type "me.t, Psvi La .. ' ., Code Code Code 9106-0001-112D SE C BP X NOTES: PO #: 002332 MSR #: 06- ti .c SSWP# NA Z LTP QA FE Radwaste QA nl Non QA Samples Shipped Via-. , i,, FedEx L UPS ElHand tU Sde?1) Relinquished By Date/Time  
$ Laap t)Sample Designation Date Time Media Type &Type "me.t, Psvi La .. ' ., Code Code Code 9106-0001-112D SE C BP X NOTES: PO #: 002332 MSR #: 06- ti .c SSWP# NA Z LTP QA FE Radwaste QA nl Non QA Samples Shipped Via-. , i,, FedEx L UPS ElHand tU Sde?1) Relinquished By Date/Time
: 2) Received By Date/Time  
: 2) Received By Date/Time  
'Clul 'Uidy&#xa2;i d.rt4A4F~  
'Clul 'Uidy&#xa2;i d.rt4A4F~  
-/o /fAA .E Other nat 3) Relinquished By Date/Time  
-/o /fAA .E Other nat 3) Relinquished By Date/Time
: 4) Received By Date/Time
: 4) Received By Date/Time
___._________,_
___._________,_
_ YII 4 .Bill of Lading #5) Relinquished By Date/Time  
_ YII 4 .Bill of Lading #5) Relinquished By Date/Time
: 6) Received By Date/Time 0 150/ ,/j9 3 46Uv Connecticut Yankee -C-SO-O01 Statement of Work for Analytical Lab Services Figure 1. Sample Check-in List DatelfimfteReceived:  
: 6) Received By Date/Time 0 150/ ,/j9 3 46Uv Connecticut Yankee -C-SO-O01 Statement of Work for Analytical Lab Services Figure 1. Sample Check-in List DatelfimfteReceived:  
..... , , SDG#: .Work order Number: -18 1 Z, Shipping C_3ntainer ID: .qzj S/_f Chain of Custody#..
..... , , SDG#: .Work order Number: -18 1 Z, Shipping C_3ntainer ID: .qzj S/_f Chain of Custody#..
Line 744: Line 744:
Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Co -60 Survey Unit: 9106-0001 Survey Unit Name: Discharge Canal Mean: 0.406 pCi/g 20 ,15 Cr u- 5 -.: 0 0 ' I --Ii 0.00 0.50 1.00 1.50 2.00 2.50 3.00 Upper End Value (pCi/g)Upper End Observation Observation Value Frequency Frequency 0.00 5 17%0.50 16 53%1.00 7 23%1.50 0 0%2.00 1 3%2.50 0 0%3.00 1 3%Total 30 100%Prepared By: Date: Reviewed By: Date: / /-I -O~Reviewed By: Date:
Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Co -60 Survey Unit: 9106-0001 Survey Unit Name: Discharge Canal Mean: 0.406 pCi/g 20 ,15 Cr u- 5 -.: 0 0 ' I --Ii 0.00 0.50 1.00 1.50 2.00 2.50 3.00 Upper End Value (pCi/g)Upper End Observation Observation Value Frequency Frequency 0.00 5 17%0.50 16 53%1.00 7 23%1.50 0 0%2.00 1 3%2.50 0 0%3.00 1 3%Total 30 100%Prepared By: Date: Reviewed By: Date: / /-I -O~Reviewed By: Date:
DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD Attachment 2e Sign Test Calculation (2 Page)
DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD Attachment 2e Sign Test Calculation (2 Page)
Health Physics Procedure GPP-GGGR-R512 1 -000 Attachment A, Rev. CY-00 I MAJOR Sign Test Calculation Sheet For Multiple Radionuclisdes Survey Unit Number: 9106-0001 Survey Unit Name: Discharge Canal WP&IR#: 2006-021 Classification  
Health Physics Procedure GPP-GGGR-R512 1 -000 Attachment A, Rev. CY-00 I MAJOR Sign Test Calculation Sheet For Multiple Radionuclisdes Survey Unit Number: 9106-0001 Survey Unit Name: Discharge Canal WP&IR#: 2006-021 Classification
: 1 TYPE I (cc error):0.05 ITYPE I (P3 error):0.05 Radionuclides:
: 1 TYPE I (cc error):0.05 ITYPE I (P3 error):0.05 Radionuclides:
Survey Design DCGL (pCi/g): Cs-137 Co-60 5.38 2.59 Results Cs-137 5.04E-0 1 9.09E-0 I 2.89E-01 1.63E-01 6.95E-01 2.07E-02-6.78E-04 6.09E-02 1.61E-01 2.34E+00 3.87E-01 7.93 E-0 1 7.60E-0 1 1.38E-02 1.38E-02 2.20E-01 7.39E-01 7.43E-01 4.59E-01 6.77E-0 1 2.85E-01 2.7 1E-02 2.44E-0 1 4.78E-01 8.50E-01 6.1OE-02 0.OOE+00 5.66E-0 1 5.58E-01 6.08E-01 Results Co-60 1.28E-02 4.14E-01 3.15E-02 1.48E-01 2.46E-0 1 1.70E-02-4.42E-03 0.00E+00 1.14E-01 2.65E+00 2.59E-01 3.70E-0 1 5.97E-01 3.26E-02 5.25E-04 1.12E-01 7.08E-01 6.27E-0 1 4.22E-0 1 7.65E-01 2.54E-01 0.OOE+00 1.07E-01 7.86E-01 8.18E-01-3.30E-03 0.OOE+00 2.58E-01 1.66E+00 7.84E-01 Weighted Sum (W,)1.58E-01 3.88E-01 1.25E-01 1.47E-0 1 2.83E-01 6.95E-02 5.73E-02 7.04E-02 1.33E-01 1.53E+00 2.3 1E-01 3.49E-01 4.3 1E-01 7.43E-02 6.19E-02 1.43E-01 4.70E-0 1 4.04E-0 1 3.07E-0 1 4.80E-01 2.1OE-01 6.42E-02 1.46E-01 4.51E-01 5.33E-0 1 6.92E-02 5.91E-02 2.64E-0 1 8.29E-01 4.75E-0 1 DCGL-Result 8.42E-0 1 6.12E-01 8.75E-0 1 8.53E-01 7.17E-01 9.30E-01 9.43E-01 9.30E-0 1 8.67E-0 1-5.27E-0 1 7.69E-0 1 6.51E-01 5.69E-0 1 9.26E-01 9.38E-01 8.57E-01 5.30E-01 5.96E-0 1 6.93E-01 5.20E-01 7.90E-0 1 9.36E-01 8.54E-0 1 5.49E-0 1 4.67E-0 1 9.3 1E-01 9.41E-01 7.36E-01 1.71E-01 5.25E-01 C-14 3.85 Sign 1 1 1 1 1 1 Number of Positive Differences (S+): 29 Page 1 of 2 Health Physics Procedur Critical Value: GPP-GGGR-R5121-000 Attachment A, Rev. CY-001 MAJOR Survey Unit: Meets Acceptance Criterion 19 Performed By: _ _ _ _ _ _ _ _Independent Review: Date: Date: Page 2 of 2 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD Attachment 2f COMPASS DQA Surface Soil Report with Retrospective Power Curve (5 Pages)
Survey Design DCGL (pCi/g): Cs-137 Co-60 5.38 2.59 Results Cs-137 5.04E-0 1 9.09E-0 I 2.89E-01 1.63E-01 6.95E-01 2.07E-02-6.78E-04 6.09E-02 1.61E-01 2.34E+00 3.87E-01 7.93 E-0 1 7.60E-0 1 1.38E-02 1.38E-02 2.20E-01 7.39E-01 7.43E-01 4.59E-01 6.77E-0 1 2.85E-01 2.7 1E-02 2.44E-0 1 4.78E-01 8.50E-01 6.1OE-02 0.OOE+00 5.66E-0 1 5.58E-01 6.08E-01 Results Co-60 1.28E-02 4.14E-01 3.15E-02 1.48E-01 2.46E-0 1 1.70E-02-4.42E-03 0.00E+00 1.14E-01 2.65E+00 2.59E-01 3.70E-0 1 5.97E-01 3.26E-02 5.25E-04 1.12E-01 7.08E-01 6.27E-0 1 4.22E-0 1 7.65E-01 2.54E-01 0.OOE+00 1.07E-01 7.86E-01 8.18E-01-3.30E-03 0.OOE+00 2.58E-01 1.66E+00 7.84E-01 Weighted Sum (W,)1.58E-01 3.88E-01 1.25E-01 1.47E-0 1 2.83E-01 6.95E-02 5.73E-02 7.04E-02 1.33E-01 1.53E+00 2.3 1E-01 3.49E-01 4.3 1E-01 7.43E-02 6.19E-02 1.43E-01 4.70E-0 1 4.04E-0 1 3.07E-0 1 4.80E-01 2.1OE-01 6.42E-02 1.46E-01 4.51E-01 5.33E-0 1 6.92E-02 5.91E-02 2.64E-0 1 8.29E-01 4.75E-0 1 DCGL-Result 8.42E-0 1 6.12E-01 8.75E-0 1 8.53E-01 7.17E-01 9.30E-01 9.43E-01 9.30E-0 1 8.67E-0 1-5.27E-0 1 7.69E-0 1 6.51E-01 5.69E-0 1 9.26E-01 9.38E-01 8.57E-01 5.30E-01 5.96E-0 1 6.93E-01 5.20E-01 7.90E-0 1 9.36E-01 8.54E-0 1 5.49E-0 1 4.67E-0 1 9.3 1E-01 9.41E-01 7.36E-01 1.71E-01 5.25E-01 C-14 3.85 Sign 1 1 1 1 1 1 Number of Positive Differences (S+): 29 Page 1 of 2 Health Physics Procedur Critical Value: GPP-GGGR-R5121-000 Attachment A, Rev. CY-001 MAJOR Survey Unit: Meets Acceptance Criterion 19 Performed By: _ _ _ _ _ _ _ _Independent Review: Date: Date: Page 2 of 2 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD Attachment 2f COMPASS DQA Surface Soil Report with Retrospective Power Curve (5 Pages)

Revision as of 09:11, 13 July 2019

Final Status Survey Final Report Phase IV, Appendix A1 Survey Unit Release Record 9106-0001, Discharge Canal
ML063400429
Person / Time
Site: Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 11/21/2006
From: Newson C
Connecticut Yankee Atomic Power Co
To:
NRC/FSME
References
9106-0001
Download: ML063400429 (251)


Text

Final Status Survey Final Report Phase IV Appendix Al Survey Unit Release Record 9106-0001, Discharge Canal November 2006 CYAPCO FINAL STATUS SURVEY RELEASE RECORD DISCHARGE CANAL SURVEY UNIT 9106-0001 Prepared By: Reviewed By: FSS Engineer Date: 11-11-104,<

Date: Date: / /d/FýS Enginelr Approved By: C4lL~ 7-,.]---Technical Support Manager Revision 0 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD TABLE OF CONTENTS 1. SURVEY UNIT DESCRIPTION

.......................................................

3 2. CLASSIFICATION BASIS ...............................................................

3 3. DATA QUALITY OBJECTIVES (DQO) ..........................................

5 4. SU RV EY D ESIGN ............................................................................

10 5. SURVEY IMPLEMENTATION

.......................................................

14 6. SUR VEY RESULTS ..........................................................................

14 7. QUALITY CON TROL .....................................................................

17 8. INVESTIGATIONS AND RESULTS ..............................................

17 9. REMEDIATION AND RESULTS ..................................................

21 10. CHANGES FROM THE FINAL STATUS SURVEY PLAN ...... 21 11. DATA QUALITY ASSESSMENT (DQA) ......................................

21 12. A N O M A L IE S ..................................................................................

22 13. C O N CLU SIO N ................................................................................

22 14. A TTA CHM EN TS ............................................................................

23 14.1 Attachment 1 -Figures (6 pages including cover)14.2 Attachment 2 -Sample and Statistical Data (221 pages including covers)Revision 0 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD SURVEY UNIT DESCRIPTION Survey Unit 9106-0001 (Discharge Canal) is designated as Final Status Survey (FSS) Class 1 survey area and consists of approximately 1,917 m 2 (0.47 acres)of water covered sediment in an area located approximately 0.16 miles from the reference coordinate system benchmark used at the Haddam Neck Plant (FHNP)(see Attachment 1, Figure 1). The Discharge Canal is a man-made mile long waterway that runs parallel to, and ultimately communicates with, the Connecticut River. The Discharge Canal is subdivided into fifteen (15) survey units including two (2) permanent wetland areas for FSS purposes.

The survey unit is bounded as follows: Survey Area 9522 is to the north and east (called north as orientated with the north to south flow of the Connecticut River), Survey Area 9520 is to the north and west, Discharge Canal Survey Unit 9106-0014 is to the south. The survey unit comprises the canal sediments to the depth of three feet from the top of the sediment layer or the original construction depth and it extends up the canal banks to the mean high water level.This survey unit is bounded by reference coordinates E006 through EO10 and by S072 through S078 (refer to License Termination Plan Section 5.4.4). The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit; some areas contained in this rectangle may not be part of this survey unit. The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.2. CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10,"Survey Unit Classification. " The "Classification Basis Summary" conducted for this survey unit consisted of: a) A review of the 10CFR50.75 (g) (1) database, b) A review of the "Initial Characterization Report" and the "Historic Site Assessment (HSA) Supplement, " c) Historic and current survey records review, d) Visual inspections and a "walkdown." e) Formal or informal interviews with cognizant personnel.

A review of the 1OCFR50.75(g)(1) database report identified a number of events that may have impacted this survey unit. This was expected since the discharge canal served as the licensed discharge pathway for liquid releases.Several events indicated the potential for plant related contamination in the survey unit. These included a number of primary side system to secondary side system leakage events, contamination found to be present in secondary side systems and components, and unmonitored spills that drained to the discharge canal. In 1986, samples were taken from the legacy dredge spoils removed in 1979 dredged spoils area and from recently dredged canal sediment.

The Revision 0 3 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD sample analyses indicated that the concentrations of Cs-137, Co-60 and other radionuclides were a small fraction of the Derived Concentration Guideline Limits (DCGLs) for those nuclides that could be identified by gamma spectroscopy. (refer to NE-86-RA-1142 dated 11-13-86).

None of the available historical information reviewed would support a conclusion that any residual activity in this survey unit is likely to be present at concentrations greater than the respective DCGLs.Additional information was provided by several historical documents, including the "Results of Scoping Survey", (completed 9/1/98), the "Historical Site Assessment", and the Historical Site Assessment (HSA) Supplement (dated 6-30-00). These documents presented the results of several sediment samples taken in 1997. These sample results indicated concentrations of 0.5 pCi/g for Co-60, 0.024 pCi/g for Cs-134 and 0.722 pCi/g for Cs-137.This area was initially a larger Class 2 survey unit, also designated as 9106-0001. Upon reviewing the FSS data for this area, it was determined that at least one (1) sample exceeded the DCGL for the area. This required that the area be reclassified as two (2), Class 1 survey units. In order to optimize the amount of area covered by the Class 1 surveys, a portion of Class 2 Survey Unit 9106-0002 was also included into the southern most area of the two newly designated Class 1 survey units. Survey Unit 9106-0001 encompasses the northern portion of the newly reclassified area and Survey Unit 9106-0014 (new) encompasses the southern portion of the newly reclassified area.An initial characterization was performed in April and May of 2004 to obtain the necessary data of sufficient data quality for final status survey (FSS)planning purposes.

Fifteen (15) samples were obtained by biased sampling from five (5) locations throughout the area. The samples were analyzed, at an approved off-site laboratory, by gamma spectroscopy and with radiochemical analyses for Sr-90 and Tritium. Hard-to-Detect analyses were also conducted on one (1) of the fifteen (15) samples. The only plant-related dosimetrically significant radionuclides identified in the samples were Cs-137 and Co-60. All sample analysis results were below the ten (10) mrem/yr design DCGL. Co-60 accounted for the majority of the dose in these samples with a maximum concentration of 1.04 pCi/g.A final characterization survey was performed in May of 2006. Samples were collected and analyzed on-site by gamma spectroscopy.

Fifteen (15) sediment samples from fifteen (15) locations were collected and analyzed for radioactive materials.

All of the samples were analyzed by gamma spectroscopy.

A summary of the results are presented in Table 1 below.Revision 0 4 DISCHARGE CANAL SURVEY UNIT 9106-000 1 RELEASE RECORD Minimum Value: 2.15E-02 1.03E-03 Maximum Value: 1.57E+00 2.25E+00 Mean: 5.96E-01 6.15E-01 Median: 6.39E-01 3.81E-01 Standard Deviation:

4.96E-01 6.97E-01 NOTE: The Operational DCGLs from Table 2 are 5.38 pCi/g for Cs-137 and 2.59 pCi/g for Co-60; these are used in conjunction with the unity rule to achieve seventeen (17)mrem/yr Total Effective Dose Equivalent (TEDE).Based upon the results of radiological surveys performed during characterization, it was concluded that there was a significant probability for residual radioactivity to be present in this survey unit in concentrations greater than the Operational DCGL justifying a final survey unit classification of Class 1 (refer to Section 3).Since the pre-remediation data presented in Table 1 is determined to be sufficient to adequately characterize the survey area, no further characterization efforts were undertaken.

A Class 1 Final Status Survey (FSS) plan was developed and implemented in this survey unit starting in May of 2006.Prior to completion of the FSS plan, it was determined that a remediation was required to remove sediment material in a region exceeding the associated DCGLEMC. A post-remediation Remedial Action Survey (RAS) was performed under SSWP 06-07-002.

This survey confirmed that grab samples of the dredge spoils materials were below the Operational DCGL, indicating that remediation was completed in the affected areas.The FSS Engineer performed a visual inspection and walk-down during July 2006 to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.

3. DATA QUALITY OBJECTIVES (DQO)FSS design and planning is based on the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5.1-11, "Preparation of Final Status Survey Plan, " and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARSSIM).

A summary of the main features of the DQO process are provided herein.The DQO process incorporates hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis.

Hypothesis testing is a process based on the scientific method that compares a baseline condition to Revision 0 5 Revision 0 5 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD an alternate condition.

The baseline condition is technically known as the null hypothesis.

Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection.

In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria.

Rejection of the null hypothesis would satisfy the release criteria objective of the FSS.The primary objective of the Final Status Survey Plan (FSSP) was to demonstrate that the level of residual radioactivity in Survey Unit 9106-0001 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity.

This is done through the development of DCGLs. The DCGLs represent the concentration of radioactivity above background, equivalent to a dose-based release criterion and is presented in terms of surface or mass activity concentrations.

Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL), for existing groundwater radioactivity and for future groundwater radioactivity that will be contributed by building foundations and footings.As described in detail in the LTP, the dose model applied to the discharge canal presumes that the canal sediments are dredged to a depth of three (3) feet below the top of the sediment layer and spread for the planting of crops per the Resident Farmer Scenario.

Consequently, the soil DCGLs are directly applied to the canal sediment media The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity.

Equation 1 shows the mathematical relationship between the three (3) components and the total dose.Equation 1: HTotal-Hsoii (sediment)

+ HExisting GW + HFuture GW The total dose under the LTP criteria is twenty-five (25) mrem/yr TEDE from all three (3) components.

The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for Connecticut Yankee (CY) is nineteen (19) mrem/yr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the groundwater dose values discussed above.Revision 0 6 Revision 0 6 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD This survey unit is affected by existing groundwater (reference CY memo ISC 06-024). The dose contribution from existing groundwater is less than two (2)mrem/yr TEDE, based on field data.This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no concrete foundations or footings remaining within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater is zero (0) mrem/yr TEDE.Equation 2.19 mrem/yrTotai=

17 mrem/yrso 1 l+2 mrem/yrExisting GW+O mrem/yrFuture GW The allowable dose for soil in this survey unit is seventeen (17) mrem/yr TEDE as shown by Equation 2 above. The concentration of residual radioactivity resulting in seventeen (17) mrem/yr TEDE is designated as the Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2.Note: The survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 to conservatively account for the contribution to the total dose from existing and future groundwater which had not been established at the time of planning the FSS.Revision 0 7 Revision 0 7 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD C-14 5.66E+00 3.85E+00 2.26E-01 Mn-54 1.74E+01 1. 18E+01 6.96E-0I Fe-55 2.74E+04 1.86E+04 1.1OE+03 Co-60 3.81E+00 2.59E+00 1.52E-01 Ni-63 7.23E+02 4.92E+02 2.89E+O1 Sr-90 1.55E+00 1.05E+00 6.20E-02 Nb-94 7.12E+00 4.84E+00 2.85E-01 Tc-99 1.26E+O1 8.57E+00 5.04E-0I Ag- 108m 7.14E+00 4.86E+00 2.86E-01 Cs-134 4.67E+00 3.18E+00 1.87E-01 Cs-137 7.91E+00 5.38E+00 3.16E-01 Eu-152 1.01E+01 6.87E+00 4.04E-01 Eu- 154 9.29E+00 6.32E+00 3.72E-01 Eu-155 3.92E+02 2.67E+02 1.57E+01 Pu-238 2.96E+O1 2.01 E+O1 1.18E+00 Pu-239/240 2.67E+0 1 1.82E+01 1.07E+00 Pu-241 8.70E+02 5.92E+02 3.48E+01 Am-241 (5) 2.58E+0I 1.75E+01 1.03E+00 Cm-243/244 2.90E+0 I 1.97E+0 1 1.16E+00 (1) Bold indicates those radionuclides considered to be Hard to Detect (HTD).(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to twenty-five (25) mrem/yr TEDE.(3) The Operational DCGL is equivalent to seventeen (17) mrem/yr TEDE.(4) The required MDC is equivalent to one (1) mrem/yr TEDE.(5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopy's when both analyses are performed.

Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability.

Initial characterization was performed in April and May of 2004 and final characterization in May of 2006 as discussed in Section 2. Cs-137 and Co-60 were found to be the predominate radionuclides of concern. The basic statistical quantities (i.e., mean, standard deviation, median) for Cs- 137 and Co-60 are provided in Table 1.As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Detectable Concentration

(<MDC) were not accepted for FSS. Sample report Revision 0 8 Revision 0 8 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD summaries included unique sample identification, analytical method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.The Elevated Measurement Comparison (EMC) consists of comparing each measurement from the survey unit with the investigation levels discussed in Section 4.0 (and presented in Table 4). As stated in section 5.8.3 of the LTP, any measurement from the survey unit that is greater than an investigation level indicates an area of relatively high concentrations that should be investigated, regardless of the outcome of the nonparametric statistical tests. Thus the use of the EMC against the investigation levels may be viewed as assurance that unusually large measurements will receive proper attention regardless of the outcome of those tests and that any area having the potential for significant dose contributions will be identified.

The LTP (by way of Equation 5-31) states that if elevated levels of residual radioactivity are present over portions of the survey unit area, they will be evaluated in conjunction with the average level of residual activity present across the balance of the survey unit to determine whether the total dose associated with the distribution of activity present is in compliance with the release criteria.

This is demonstrated in Equation 3.Revision 0 9 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD Equation 3 (LTP Equation 5-31)."+ C elevated -<1 <DCGLW (AreaFactor) x DCGL W Where: (5 = Average concentration outside the elevated area, Celeaed = Average concentration inside the elevated area.A separate term will be used in Equation 3 for each elevated area in a survey unit.4. SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans ".The dose for soil used for this survey unit to demonstrate compliance with the LTP criteria is seventeen (17) mrem/yr TEDE, as discussed in Section 3 of this Release Record.The DQO process determined that Cs-137 and Co-60 were the radionuclides of concern (refer to Section 2). The sum of fractions or unity rule was used with the individual Operational DCGLs because multiple radionuclides (Cs-137 and Co-60) were considered in the survey design.Surrogate DCGLs were not required for this survey unit based on process knowledge from FSS of nearby adjacent areas and via screening process described in LTP Section 5.4.7.2, "Gross Activity DCGLs".Radionuclide screening or de-selection is a process where an individual radionuclide or aggregate may be considered insignificant and eliminated from the FSS. The criteria for de-selection are concentrations that are less than 5%for individual radionuclides and that are less than 10% for the aggregate of all radionuclides that are de-selected.

This process was applied to analysis data for this survey unit.The Elevated Measurement Comparison (EMC) applies to this survey unit since it is a Class 1 area and discrete, elevated areas of contamination are expected.A description of the application of the EMC is provided in section 3.0.Revision 0 10 Revision 0 10 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD The Sign Test was selected as the non-parametric statistical test to demonstrate that the null hypothesis was rejected.

The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation.

In addition, this approach is conservative since it includes background Cs-137 as part of the sample set.The number of sediment samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Samples for Final Status Survey. " The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5.1-11 to 0.652 to maintain the relative shift (A/o) in the range of 1 and 3. The resulting relative shift was 2.3. A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of MARSSIM in support of the decommissioning license termination rule (10 CFR 20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design.This indicates that the survey unit has a high probability of rejecting the null hypothesis, assuming that the characterization data are representative of the FSS results. For statistical purposes, the survey design specified fifteen (15) samples were required.

However, due to a special requirement to double the number of statistical samples in this section of the discharge canal, resulting from an agreement with the State of Connecticut Department if Environmental Protection (CTDEP), this number needed to be doubled to thirty (30) sediment core samples for non-parametric statistical testing.The grid pattern and locations of the sediment samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14,"Identifying, and Marking Surface Sample Locations for Final Status Survey. " VSP was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A systematic triangular grid pattern with a random starting point was selected for sample design, which is appropriate for a Class 1 area.Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.Revision 0 11 Revision 0 11 DISCHARGE CANAL SURVEY UNIT 9 106-0001 RELEASE RECORD Table 3 -Sample Measurement oaioswt Asscite GSCo~ordinates 9106-0001

-101F 236249.32 668909.83 9106-0001-103F 236224.86 668923.95 9106-0001-104F 236224.86 668952.20 9106-0001-106F 236200.40 668881.58 9106-0001-107F 236200.40 668966.32 9106-0001-108F 236200.40 668994.57 9106-0001-1 09F 236200.40 669022.82 9106-0001

-11 OF 236175.93 668867.45 9106-0001

-111IF 236175.93 668895.70 9106-0001-112F 236175.93 668923.95 9106-0001-113F 236175.93 668952.20 9106-0001-1 14F 236175.93 668980.44 9106-0001-1 1SF 236175.93 669008.69 9106-0001-1 16F 236175.93 669036.94 9106-0001-1 17F 236175.93 669065.19 9106-0001-119F 236151.47 668909.83 9106-0001-120F 236151.47 668938.07 9106-0001-12 1F 236151.47 668966.32 9106-0001-122F 236151.47 668994.57 9106-0001-123F 236151.47 669022.82 9106-0001-124F 236151.47 669051.06 9106-0001-125F 236127.01 668923.95 9106-0001-126F 236127.01 668952.20 9106-0001-127F 236127.01 668980.44 9106-0001-128F 236127.01 669008.69 9106-0001-129F 236102.55 668966.32 9106-0001-130F 236102.55 668994.57 9106-0001-131IF 236178.99 668971.40 9106-0001-132F 236118.53 669020.35 9106-0001-133F 236172.48 669019.85 The sample location designations of Table 3 are not sequentially inclusive because of the necessity to relocate samples due to the inaccessibility of original sample locations.

Sample locations 9106-0001-102F, 9106-0001-105F and 9106-0001-1 18F were found to be on dry land. Consequently, they were randomly re-located using the VSP software to three (3) new locations designated as 9106-0001-13 IF through 9106-001-0133F.

The sample plan specified that all sample were to be collected within three (3)meters of the specified coordinates.

This is a satisfactory positioning tolerance given the challenges associated with positioning the sampling vessel to fixed locations.

In addition, sample procurement was, at times, hindered by rock and other obstructions that limited the penetration of the coring device and in some Revision 0 1 12 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD cases prevented sampling all together.

The vendor's positioning logs were reviewed to determine that the positioning was within the specified tolerances.

It was determined that for this survey unit, the maximum sample location offset was found to be 8.51 feet (2.59 meters) at sample point 9106-0001-119.

Three (3) sediment samples were analyzed for the full suite of radionuclides specified in Table 1, exceeding the requirement to analyze 5% of the sample population for HTD analysis specified in procedure RPM 5.1-11. Two (2) of the three (3) samples were randomly selected using the Microsoft Excel"RAND" function.

Additionally, the gamma results were screened to ensure that the sample exhibiting the highest observed radionuclide concentration by gamma analysis was selected.

This process resulted in selecting an additional sample for HTD analyses.The implementation of quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey, " required the collection of two (2) samples for "split sample" analysis by the off-site laboratory.

These locations were selected randomly using the Microsoft Excel"RAND" function.

The number of quality control samples exceeded the 5%requirement as specified by the LTP.Section 5.7.3.2.6 of the LTP specifies that scanning is not required for the FSS of the Discharge Canal. Table 4 provides a synopsis of the survey design._____________

Table 4 -Svnopsis of the Survey Designi Feature' Des~igin Criteria.

<jBasis Survey Unit 1,917 m 2 Based on AutoCAD-LT and VSP Land Area calculations Type I and Type 2 errors were 0.05, Number of 30 sigma was 0.284 the LBGR was set to Measurements(')

0.652 to maintain Relative Shift in the range of I and 3, Relative Shift was 2.3 Grid Spacing 8.59 m Based on triangular grid To achieve seventeen (17) mrem/yr Operational 5.38 pCi/g Cs-137 TEDE (2) to demonstrate compliance with DCGL 2.59 pCi/g Co-60 Equation 2 of this Release Record Scan Coverage N/A The LTP exempts this area Sediment 5.38 pCi/g Cs-137 The Operational DCGL meets the LTP Investigation 2.59 pCi/g Co-60 criteria for a Class 1 survey unit Level criteria foraClassIsurveyunit (1) Section 5.7 of the LTP requires that the calculated number of statistical samples (n= 15)be doubled for this survey unit.(2) The allowable dose for soil in this survey unit is seventeen (17) mrem/yr TEDE as the bounding dose from existing and future groundwater has been established based on field data (reference CY memo ISC 06-024).Revision 0 13 Revision 0 13 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD 5. SURVEY IMPLEMENTATION Final Status Survey field activities were conducted under Work Plan and Inspection Record (WP&IR) 2006-0021.

The WP&IR package included a detailed FSSP, job safety analysis, job planning checklist and related procedures for reference.

Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.Measurement locations were identified in North American Datum (NAD) 1927 coordinates that were supplied to the sampling vendor, Ocean Survey, Inc.(OSI) of Old Saybrook, Connecticut.

Discharge Canal sampling was accomplished using direct push technology to collect composite samples of bottom and mean high water mark sediments.

Sediment cores from the Discharge Canal were obtained by OSI using a vibrating corer that is platform mounted on a sampling vessel. The core barrel was a three (3) inch diameter thin-walled aluminum tube which also served as a core liner (ten feet or less).A core catcher was available to prevent the sample from sliding out of the bottom of the tube. Vessel positioning and the determination of sample locations were accomplished using a GPS interfaced with a navigation and data logging system.After extraction, water was drained from above the sample by drilling holes above the sediment.

The liner was cut, capped, sealed, labeled and turned over to site personnel who processed and controlled the samples under Chain of Custody (COC) protocols in accordance with procedure RPM 5.1-5, "Chain of Custody for Final Status Survey Samples. " Rinsing of the barrel and associated equipment was performed between sampling events. New aluminum tubes were used for each sample to prevent cross-contamination of subsequent samples.The thirty (30) sediment samples were collected and packaged in accordance with Haddam Neck Plant (HNP) Procedure RPM 5.1-3, "Collection of Sample Media for Final Status Survey". Samples were controlled, transported, stored, and transferred to the off-site laboratory using COC protocols.

Three (3) samples (9106-0001-112F, 9106-0001-121F and 9106-0001-132F) were selected for HTD radionuclide analysis by the off-site laboratory.

The implementation of quality control measures included the collection of two (2) split samples at locations 9106-0001-106F and 9106-0001-117F for comparative analysis by the off-site laboratory.

6. SURVEY RESULTS The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories (GEL) -Charleston, South Carolina.

The Revision 0 14 Revision 0 14 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD laboratory analyzed the thirty (30) samples taken for non-parametric statistical testing and the associated duplicates using gamma spectroscopy.

All analyses were performed to the required MDC.Cs-137 was positively identified (i.e., a result greater than two (2) standard deviations uncertainty) in twenty-five (25) and Co-60 was positively identified in twenty-one (21) of the thirty (30) samples. The results reported for the remaining sample analyses indicated that activity was present at levels approaching or below the established detection limits in the remaining samples collected and analyzed for non-parametric testing.Several other radionuclides which were positively identified (i.e., a result greater than two (2) standard deviations uncertainty) could be de-selected or excluded using the 5% and 10% rule described in Section 5.4.7.2 of the LTP.One (1) of the sample results exceeded the Operational DCGL and required further investigation.

A summary of the sample results is provided in Table 5.Revision 0 15 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD 9106-0001-103F 9.09E-0 I 4.14E-01 3.29E-01 3.88E-01 9106-0001-104F 2.89E-01 3.15E-02 6.59E-02 1.25E-01 9106-0001-106F 1.63E-01 1.48E-01 8.74E-02 1.47E-01 9106-0001-107F 6.95E-01 2.46E-01 2.24E-01 2.83E-01 9106-0001-108F 2.07E-02 1.70E-02 1.04E-02 6.95E-02 9106-0001-109F

-6.78E-04

-4.42E-03

-1.83E-03 5.73E-02 9106-0001-11OF 6.09E-02 0.OOE+00 1.13E-02 7.04E-02 9106-0001-111F 1.61E-01 1.14E-01 7.39E-02 1.33E-01 9106-0001-112F 2.34E+00 2.65E+00 1.46E+00 1.53E+00 9106-0001-113F 3.87E-01 2.59E-01 1.72E-01 2.3 1E-01 9106-0001-114F 7.93E-01 3.70E-01 2.90E-01 3.49E-01 9106-0001-115F 7.60E-01 5.97E-01 3.72E-01 4.3 1E-01 9106-0001-116F 1.38E-02 3.26E-02 1.52E-02 7.43E-02 9106-0001-117F 1.38E-02 5.25E-04 2.77E-03 6.19E-02 9106-0001-119F 2.20E-01 1.12E-01 8.41E-02 1.43E-01 9106-0001-120F 7.39E-01 7.08E-01 4.11E-01 4.70E-01 9106-0001-121F 7.43E-01 6.27E-01 3.80E-01 4.04E-0 1 9106-0001-122F 4.59E-01 4.22E-01 2.48E-01 3.07E-01 9106-0001-123F 6.77E-01 7.65E-01 4.21 E-01 4.80E-01 9106-0001-124F 2.85E-01 2.54E-01 1.51E-01 2.1OE-01 9106-0001-125F 2.71E-02 0.OOE+00 5.04E-03 6.42E-02 9106-0001-126F 2.44E-01 1.07E-01 8.67E-02 1.46E-01 9106-0001-127F 4.78E-01 7.86E-01 3.92E-01 4.51 E-01 9106-0001-128F 8.50E-01 8.18E-01 4.74E-01 5.33E-01 9106-0001-129F 6.1 OE-02 -3.30E-03 1.01E-02 6.92E-02 9106-0001-13OF 0.OOE+00 0.OOE+00 0.OOE+00 5.91E-02 9106-0001-131F 5.66E-01 2.58E-01 2.05E-01 2.64E-01 9106-0001-132F 5.58E-01 1.66E+00 7.45E-01 8.29E-01 9106-0001-133F 6.08E-01 7.84E-01 4.16E-01 4.75E-01 (1) The Operational DCGLs from Table 2 are 5.38 pCi/g for Cs-137 and 2.59 pCi/g for Co-60;these are used in conjunction with the unity rule to achieve seventeen (17) mrem/yr TEDE (2) This column is the sum of the DCGL unity fraction from identified radionuclides of concern and an HTD isotope (C-14) that exceeded the 5%/10% rule for one (1) or more FSS samples. For those samples not measured for HTD isotopes, an average calculated value of 5.9% of the DCGL was added to each sample.Revision 0 16 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD The off-site laboratory also processed a total of three (3) samples for full HTD analysis as required by the sample plan, and for gamma results that indicated additional testing was warranted.

The requested analyses included alpha spectroscopy and liquid scintillation depending upon the radionuclide and the measurement method. All analyses were performed to the required MDC.Several of the HTD radionuclides met the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty) in one (1) or more samples; however, each of the positive results for HTD radionuclides could be de-selected based on the 5% and 10% rules, except for C-14. These results are presented in Table 6., ['able 6-H ad-to-Detct Sam~ple Results Sample Number C-'-14 Fraction of the....

onGL : 9106-0001-112F 9.16E-02 0.0238 9106-0001-121F 2.67E-01 0.0694 9106-0001-132F 3.24E-01 0.0842 (1) The Operational DCGL from Table 2 is 3.85 pCi/g for C-14.7. QUALITY CONTROL The two (2) split samples taken for QC were analyzed by the off-site laboratory.

The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 and as detailed in HNP Procedure RPM 5.1-24,"Split Sample Assessment for Final Status Survey. " For all QC split samples, there was an acceptable level of agreement.

The sample analysis vendor, GEL, maintained quality control and quality assurance plans as part of normal operation.

Refer to Attachment 2 for data and data quality analysis results.8. INVESTIGATIONS AND RESULTS In order to expedite the survey design and implementation, unprocessed excess sample aliquot was measured on-site in non-specification geometry (usually a plastic bag). This provided the ability to screen as many sample locations as possible, in advance of receiving the official results from the offsite laboratory, to determine whether any locations may exceed the investigation levels. In turn, this allowed locations to be investigated to assess the extent of suspected elevated areas on a shortened schedule.

This process identified two (2) sample results that appeared to exceed the Operational DCGL of seventeen (17)mrem/yr, exceeding the investigation level from Table 4. Thus investigations were required to determine compliance with Equation 3 of Section 3.The locations identified for investigation were 9106-0001-112F and 9106-0001-132F. Investigational sample plans were designed and implemented for these locations.

Revision 0 17 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD Upon receiving the official off-site laboratory results it was found that only one (1) (9106-0001-112F) of the two (2) investigated samples exceeded the Operational DCGL. However, investigational sample 9106-0001-132B, intended to bound the extent of contamination about sample 9106-0001-132F, was found to exceed the Operational DCGL. As a result, the EMC test was applied to the elevated region surrounding samples 9106-0001-112F and sample 9106-0001-132B.

The first step in assessing compliance with the EMC unity rule is to determine the extent of the elevated measurement region. In the case of elevated sample location 9106-0001-112F, this was done by taking investigation samples at a distance of approximately two (2) meters in each of the four (4) major compass directions (north, east, south, and west) about the elevated sample point. The actual area for the elevated measurement location was determined by using actual GPS log data and is graphically displayed in Figures 6 & 7 of this report.2 The extent of the elevated area was approximately 20.2 m2.For sample 9106-0001-132B, which was found to be in excess of the Operational DCGL after demobilization of the sampling contractor, the extent of the elevated area was bounded by using existing statistical sampling grid points and boundaries.

Samples 9106-0001-123F, 9106-0001-124F, 9106-0001-128F and 9106-0001-132F in conjunction with the survey area boundary with Survey Unit 9106-0014 were used to completely bound the elevated area. The actual area for the elevated measurement location was determined by using actual GPS log data and is graphically displayed in Figures 6 & 7 of this report.2 The extent of the elevated area was approximately 80.4 m2.Table 7 provides sample measurement location information (in NAD 1927) and distances from sample locations 9106-0001-112F and 9106-0001-132B respectively.

Revision 0 18 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD 9106-0001-112F 236176.63 1 668921.35 9106-0001-112A 236178.98 668927.68 2.06 9106-0001-112B 236184.70 668923.36 2.54 9106-0001-112C 236177.87 668914.97 1.98 9106-0001-112D 236169.65 668920.03 2.17 Area (m 2)"') 20.2 Area Factor Table Value m 2 25 1Designation liNorthing Easting DIsfince from..9100-000O1

-132)B 9106-0001-132B 236123.81 669022.89

-9106-0001-132F 236118.53 669020.35 1.79 9106-0001-123F 236148.80 669024.97 7.65 9106-0001-124F 236152.46 669056.08 13.37 9106-0001-128F 236124.76 669007.80 4.61 Area (m) "l) 80.4 Area Factor Table Value (M 2) 100 (1) The Area of each EMC is graphically depicted on Figures 6 & 7 of this report.Since the bounded areas were determined to be 20 m 2 and 80 m 2 respectively, the Area Factor (AF) values from Table 5-5 of the LTP for 25 m 2 and 100 m 2 were conservatively applied to determine the DCGLEMC for each nuclide. With this information, it was possible to assess compliance with the EMC rule. This is demonstrated in Table 8.Revision 0 19 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD 9106-0001-1 12F 2.34E+00 2.65E+00 2.67E-01 1.53E+00 9106-0001-112A 2.20E+00 1.83E+00 2.67E-01 1.1 8E+00 9106-0001-112B 1.48E+00 9.81 E-01 2.67E-01 7.23E-01 9106-0001-112C 7.46E-01 5.20E-01 2.67E-01 4.09E-01 9106-0001-112D 5.42E-01 3.08E-01 2.67E-01 2.89E-01 EM~C CoMparison foi ~9164!OiOO1-1 12F (Equation 3)Celevaed 1.46E+00 1.26E+00 2.67E-01 FNIK ........-S 1.1 IE+00 1.02E+00 1.75E-01 fraction " C elevaied -45 DCGLEMC 5.28E-02 2.16E-01 3.08E-05 2.68E-01 Sample Number Cs- 137 Co-60 C- 14 Fractiont of><(T p C i/' tile Qperationll Area Factor DG1 ( 100 M2) 2.93 1.41 203 DCGLEMc 15.76 3.65 782 9106-0001-132B 1.25E+00 3.56E+00 3.24E-01 1.69E+00 9106-0001-132F 5.58E-01 1.66E+00 3.24E-01 8.29E-01 9106-0001-123F 6.77E-01 7.65E-01 3.24E-01 5.05E-01 9106-0001-124F 2.85E-01 2.54E-01 3.24E-01 I 2.35E-01 9106-0001-128F 8.50E-01 8.18E-01 3.24E-011 5.58E-01 EC Comipa riso for 91 %-9j6001-13 B (Equation

'3 C elevated 7.24E-01 1.4 1E+00 3.24E-01 IAI' Cunit C ele,,,ed -45 3.67E-01 1.17E+00 2.32E-01 fraction C elevated -(5 DCGLFMC 2.33E-02 3.20E-01 2.97E-04 3.44E-01 S DCGL 6.63E-02 9.32E-02 2.38E-02 1.83E-01 EMC for sample 9106-0001-132B 3.44E-01 EMC for sample 9106-0001-112F 2.68E-01 Total For the Survey Unit (must be <1 in accordance with the LTP (Equation 5-31) & Equation 3 of this report) 7.95E-01 Revision 0 20 Revision 0 20 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD Sample 9106-0001-112A exceeded the Operational DCGL. It would not normally be acceptable to consider samples exceeding the Operational DCGL to be bounding.

However, the samples are located essentially on a survey unit boundary, (refer to the maps of attachment 2.) thus, the elevated area extent within the survey unit is bounded. More specifically, in this case, the sample was located adjacent to the concrete pad of the discharge canal outfall structure.

This structure, which was surveyed and released as part of the buried concrete dose model, was observed to have insufficient depths of sediment to permit sampling.9. REMEDIATION AND RESULTS Prior to designing and implementing this FSS, a Remedial Action Survey (RAS)was performed to determine when the remediation was complete.

When an area was believed to be remediated, grab samples were collected from the dredge spoils media and counted on-site using gamma spectroscopy.

It was determined that the remediation was completed when dredge materials from the survey unit were below the operational DCGL unitized concentrations.

10. CHANGES FROM THE FINAL STATUS SURVEY PLAN No significant changes were made to the Final Status Survey Plan as a result of remediation of a portion of the survey unit.11. DATA QUALITY ASSESSMENT (DQA)The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment. " The sample design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs.The evaluation of the Sign Test results indicates that the survey unit passes the unrestricted release criterion, thus, the null hypothesis is rejected.Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 1.The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation).

The standard deviation was slightly more than the value used for the survey design. This is represented by the shift in the retrospective power curve as shown in Attachment 2f. This would indicate a need to change the original LBGR in order to maintain the number of samples at thirty (30) to meet the Operational DCGL. However, the value of LBGR is not a critical issue as the survey unit has passed the statistical test, and the mean and median values are well below the Operational DCGL when used in conjunction with the unity rule. Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power.Therefore, the survey unit meets the unrestricted release criterion with adequate power as required by the DQOs Revision 0 21 Revision 0 21 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD The range of the data, about 4.91 standard deviations, was larger than other survey units in the discharge canal, as would be expected for a Class 1 survey unit. The difference between the mean and median was 26.6% of the standard deviation which indicates some skewness in the data. The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot shows some positive skewness as confirmed by the calculated skew of 2.62.The survey area had two (2) elevated measurement locations, which were evaluated using the EMC unity test. This resulted in a less than unity combined passing value of 0.786.All data, assessments, and graphical representations are provided in Attachment 2.12. ANOMALIES The anomalies associated with having bounding samples for elevated areas exceeding the operational DCGL are discussed in Section 8. These anomalies had no consequences with regards to the conclusion or other findings of this report.13. CONCLUSION Survey Unit 9106-0001 has demonstrated compliance with the dose based, unrestricted release criterion.

The sample data passed the Sign Test and the null hypothesis was rejected.

The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved.

Reclassification and remediation of this survey unit were required prior to performing the FSS survey presented in this document.Graphical representation of data indicates some positive skewness that is probably due to localized differences in particulate deposition rates, hydraulic velocity and sedimentation rates. The Retrospective Power Curve generated using COMPASS shows adequate power was achieved.

The survey unit was properly designated as a Class 1 survey unit.The dose contribution from sediment in this survey unit is 4.1 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.This survey unit is affected by existing groundwater (reference CY memo ISC 06-024). It has been determined that the dose contribution from groundwater sources is bounded by two (2) mrem/yr TEDE.This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component is, therefore, zero (0) mrem/yr TEDE.Revision 0 22 Revision 0 22 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD The average total dose from residual radioactivity in this survey unit, including exposures from the three (3) components as described in Section 3, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity, will not exceed 6.1 mremlyr Total Effective Dose Equivalent (TEDE).14. ATTACHMENTS 14.1 Attachment 1 -Figures 14.2 Attachment 2 -Sample and Statistical Data Revision 0 23 Revision 0 23 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD Attachment 1 Figures (6 pages)

,e4£/h~~C4I Connecticut Yankee Atomic Power Company Site Map With Reference To Survey Unit 9106-0001 A

Legend 0.285 0.793 0 0140.459 f 0.566.6770 0.85 0 0.551 NOTE: C4sim-1 3 7 ien Ia/g.0.743f3 2I 0.478 00 Connecticu yankee Atormic Power Company 9106-0001 Final Status Survey Cesifml-3 7 Posting Plot 0.254 Acua Location as recorded by Ocean Suveysw, Inc.0.37 0.258 10.765 0.422 Inaccessble Sample Location 0.627 0.818 0.786 NOTE: Cobakt-60 resuls ame given in pcilg 0 15 30 IFeet Power Company 9106-0001 Finmal Status Survey Cobalt-60 Posing Plot

DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD Attachment 2 Sample and Statistical Data DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD Attachment 2a Sample Data (199 Pages)

Table of Contents General Narrative

..................................................................

1 Chain of Custody and Supporting Documentation

...........

6 Radiological Analysis .........................................................

15 Sample Data Summary ......................................................

38 Q uality C ontrol D ata ...........................................................

102 General Narrative 1 CASE NARRATIVE For CONNECTICUT YANKEE RE: Soil PO# 002332 Work Order: 170132 SDG: MSR #06-1156 September 6, 2006 Laboratory Identification:

General Engineering Laboratories, LLC Mailing Address: P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address: 2040 Savage Road Charleston, South Carolina 29407 Telephone Number: (843) 556-8171 Summary: Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL)in Charleston, South Carolina on August 25, 2006. All sample containers arrived without any visible signs of tampering or breakage.

The chain of custody contained the proper documentation and signatures.

Analytical results were requested within seven days of receipt, with the data package due fourteen calendar days after the receipt date. The data was emailed on time on September 1,2006.The laboratory received the following sample(s):

Sample ID 170132001 170132002 170132003 170132004 170132005 Client Sample ID 9106-0001-121F 9106-0001-121F 9106-0001-127F 9106-0001-128F 9106-0001-129F GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.RO. Box 30712

  • Charleston, SC 29417 ° 2040 Savage Road (29407)Phone (843) 556-8171 -Fa2(843) 766-1178 -www.gel.com 170132006 170132007 170132008 170132009 170132010 170132011 170132012 170132013 170132014 170132015 170132016 170132017 170132018 170132019 170132020 170132021 170132022 170132023 170132024 170132025 170132026 170132027 170132028 170132029 170132030 170132031 9106-0001-130F 9106-0001-131F 9106-0001-133F 9106-0001-117F 9106-0001-1.17FS 9106-0001-113F 9106-0001-114F 9106-0001-116F 9106-0001-120F 9106-0001-104F 9106-0001-107F 9106-0001-115F 9106-0001-108F 9106-0001-119F 9106-0001-1O1F 9106-0001-103F 9106-0001-106F 9106-0001-106FS 9106-0001-11 OF 9106-0001-109F 9106-0001-111F 9106-0001-122F 9106-0001-123F 9106-0001-124F 9106-0001-125F 9106-0001-126F Items of Note: There are no items of note.Case Narrative:

Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures.

Any technical or administrative problems during analysis, data review, and reduction are listed below by analytical parameter.

Analytical Request: One soil samples was analyzed for CHALL.Twenty-nine soil samples were analyzed for FSSGAM.Internal Chain of Custody: Custody was maintained for the sample(s).

GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.P.O. Box 30712 -Charleston, SC 29417 ° 2040 Savage Road (29407)Phone (843) 556-8171 ° Fa 3 U(843) 766-1178

  • www.gel.com Data Package: The enclosed data package contains the following sections:

Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP INC.P0. Box 30712

  • Charleston, SC 29417 -2040 Savage Road (29407)Phone (843) 556-8171 -Faw4843) 766-1178

Connecticut Dept. of Navy EPA.....Forida-NELAP

....... .Georgia Idaho Illinois Indiana Kansas Kentucky Maryland--- .Massachusetts Michigan Nevada....mNew Jersey....

New York North Carolina North Carolina Drinking North Dakota Oklahoma Pennsylvania uertification UST-062 AZ.668 88-0651 42D0904046 01151CA GenEngLabs PH-0169 NFESC 413 WG-15J E87156 E87156 (FL/NELAP)

N/A 200029 C-SC-0l E-10332 90129 270 M-SCO012 9903 SC12 SC002......O2........

--45709 R-158 9904 68-485 W South Carolina 10120001/10585001/10120002 Tennessee 02934 Texas TX213-2006A U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8 8037697376 GEL Vermont Virginia N/A 00151 Washington C223 5 Chain of Custody And Supporting Documentation 6

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-00 1 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00516 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:

E] 30 D. [ 14 D. 7 D. l 3 D. Container Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Lab Sample ID Code Code Code 9106-0001-127F 8/1/06 13:59 SE C BP X Transferred from COC 2006-00480 9106-0001-128F 8/1/06 12:58 SE C BP x Transferred from COC 2006-00480 9106-0001-129F 8/7/06 08:06 SE C BP X Transferred from COC 2006-00487 9106-0001-130F 8/1/06 11:10 SE C BP X Transferred from COC 2006-00480 9106-0001-131F 8/7/06 13:32 SE C BP X Transferred from COC 2006-00487 9106-0001-133F 8/8/06 13:35 SE C BP X Transferred from COC 2006-00488 9106-0001-117F 8/3/06 12:55 SE C BP X Transferred from COC 2006-00484 9106-0001-117FS 8/3/06 12:55 SE C BP X Transferred from COC 2006-00484 NOTES: PO #: 002332 MSR #: 06-/576 SSWP# NA Z LTP QA E] Radwaste QA LI Non QA Samples Shipped Via: Internal Container Z Fed Ex Temp.: __ Deg.LIUPS C LI Hand Custody Sealed?Y L NE0 1) Relinquished By Datg/Time

2) R ed By Date/Time Custody Seal jeymf &-J4_-;Jr OherIntact?
3) Relinquished By bate/Time 4)3&*ived By > Date/TIime BillofLading

_Y Y N 0 Bill of Lading #5) Relinquished By Date/Time

6) Received By Date/Time -c9o" 37 7",?18 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major 0 Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00517 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Iaddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:

[] 30 D. E] 14 D. Z 7 D. E] 3 D. r Container Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Lab Sample ID Code Code Code 9106-0001-113F 8/3/06 08:12 SE C BP X Transferred from COC 2006-00484 9106-0001-114F 8/3/06 08:38 SE C BP X Transferred from COC 2006-00484 9106-0001-116F 8/3/06 10:04 SE C BP x Transferred from COC 2006-00484 9106-0001-120F 8/3/06 14:06 SE C BP X Transferred from COC 2006-00484 9106-0001-121F 8/3/06 14:32 SE C BP x Transferred from COC 2006-00484 9106-0001-104F 8/8/06 10:28 SE C BP X Transferred from COC 2006-00488 9106-0001-107F 8/8/06 08:59 SE C BP X Transferred from COC 2006-00484 9106-0001-115F 8/8/06 08:14 SE C BP X Transferred from COC 2006-00484 NOTES: PO #: 002332 MSR #: 06-1156 SSWP# NA Z LTP QA El Radwaste QA El Non QA Samples Shipped Via: Internal Container 0 Fed Ex Temp.: __ Deg.El ups C El Hand Custody Sealed?YB0 NE 1) Relinquished By Date/Time

2) Rece ed By Date ime Custody Seal 35OIm[ 9,A~'-L3-06,11340 OhrIntact?

3 ) R e lin q u ish ed B y D a te/T im e 4 dR -B y _"_-_ __at e/_ _im eY B N B Bill of Lading 4 5) Relinquished By Date/Time

6) Received By Date/Time Ho. .3 3 ,4Z/q Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Chain of Custody Form No. 2006-00518 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones o Priority:

F] 30 D. [] 14 D. Z 7 D. E] 3 D.Container Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Lab Sample ID Code Code Code 9106-0001-108F 8/7/06 14:42 SE C BP X Transferred from COC 2006-00487 9106-0001-119F 8/7/06 11:01 SE C BP X Transferred from COC 2006-00487 9106-0001-IO1F 7/31/06 13:25 SE C BP X Transferred from COC 2006-00478 9106-0001-103F 7/31/06 15:00 SE C BP x Transferred from COC 2006-00478 9106-0001-106F 8/2/06 08:00 SE C BP X Transferred from COC 2006-00484 9106-0001-106FS 8/2/06 08:00 SE C BP x Transferred from COC 2006-00488 9106-0001-11 OF 8/2/06 10:20 SE C BP X Transferred from COC 2006-00482 NOTES: PO #: 002332 MSR #: 06-115_6 SSWP# NA [ LTP QA [I Radwaste QA [ Non QA Samples Shipped Via: Internal Container Z Fed Ex Temp.: __ Deg.EZUPS C E] Hand Custody Sealed?yE I Relinquished By Date/Time

2) ReceivA By Dat /Time Custody Seal lame 9-z7-O /913+0 77I, .Other Intact?3) Relinquished By Date/Time
4) k ed By Bl of La-dingt Y Y N El Bill of Lading #5) Relinquished By Date/Time
6) Received By Date/Time 3 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 1 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00519 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Ln Priority:

EJ 30 D. [] 14 D. 0 7 D.E] 3 D.Container Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Lab Sample ID C ode C od e C ode _004 82 9106-0001-109F 8/2/06 09:37 SE C BP X Transferred from COC 2006-00482 9106-0001-11 IF 8/2/06 13:23 SE C BP X Transferred from COC 2006-00482 9106-0001-122F 8/4/06 07:55 SE C BP X Transferred from COC 2006-00485 9106-0001-123F 8/4/06 09:45 SE C BP X Transferred from COC 2006-00485 9106-0001-124F 8/4/06 11:18 SE C BP X Transferred from COC 2006-00485 9106-0001-125F 8/4/06 12:54 SE C BP X Transferred from COC 2006-00485 9106-0001-126F 8/4/06 13:39 SE C BP X Transferred from COC 2006-00485 NOTES: PO #: 002332 MSR #: 06-115-6 SSWP# NA Z LTP QA [1 Radwaste QA LJ Non QA Samples Shipped Via: Internal Container Z Fed Ex Temp.: _ Deg.U UPS C E] Hand Custody Sealed?__ _ _ _ _ _ __ _ _ _ _ _ _YFI N[]1) Relinquished By Date/Time

2) Receii d By .DatiTime Custody Seal-Other Intact?3) Relinquished By Date/Time
4) k By -ateimeBillofLadin Y f N [Bill of Lading #5) Relinquished By Date/Time
6) Received By Date/Time 79o 3 71 22 / 0 Connecticut Yankee Statement of Work for Analytical Lab Services .CY-ISC-SOW-OOl Figure 1. Sample Check-in List Date/Time Received: Work Order Number: -0 I -Shipping Container ID:Q .'. /RAI Chain of Custody # I. Custody Seals o6 shipping container intact? Yes, --No [ I 2. Custody Seals dated and signed? Yes [fNo 3. Chain-of-Custody record present? Yes [,jl"o [ ]4. Cooler temperature
5. Vermiculite/packing materials is: Wet [q ',y []6: Number of samples in shipping container:

_ -_"_ " _ _7. Sample holding times exceeded?

Yes []No[]8. Samples have-* .'tape -.hazard labels... lcustody seals -appropriate sample labels 9. Samples are good condition -leaking.broken -.have air bubbles 10. Were any anomalies identified in sample receipt? Yes [ ] No -+11. .Description of anomalies (include sample numbers): Sample Custodian/Laboratory:, Telephoned to: On B 11

  • Connecticut Yankee Statement of Work for Analytical Lab Services .CY-ISC-SOW-O01 Figure 1. Sample Check-in List Date/Time Received:___________________________

SDG#: Work Order Number: _ 0 [32..Shipping Cdhtainer ID., Chain of Custody# " / 7 1. Custody Seals oni shipping container intact?., -Yes L4o [I 2. Custody Seals dated and signed? Yes* [,,{o 1 ], 3. Chain-of-Custody record present? " Yes [<No I I 4. Cooler temperature

5. Vermiculite/packing materials is: Wet [ Dry [' ]6.' Number of samples in shipping container:
7. Sample holding times exceeded?

Yes , 0-I [1 8.. Samples have,'.......z~pehazard labels.....e6stody Seals .......appropriate sample labels 9. Samples ar"i good condition , _leaking-broken -.." have air bubbles 10, Were any anomalies identified in samp!c receipt? Yes [ ] No [.--11. .Description of anomalies. (include sample numbers): Sample Custodian/Laboratory::

Date: Telophoned to: On*__"_________

__-_" __-._-____

... ... ..... ...1..-12 Connecticut Yankee Statement of Work for Analytical Lab Services .CY-4SC-SOW-00l Figure 1. Sample Check-in List.DatefTlime Received:-

SDG#: Work Order Number: " Shipping Ccntainer ID: .72 7 2 ZZ-q!DChain of Custody# le -to,5/1. Custody Seals onshipping container intact?. .Yes P,,09o [)2. Custody Seals dated and signed? Yes[, i [ .3. Chain-of-Custo-iyrecord present? Yes "o 1]-4. Cooler temperature

." 5. Vermiculite/packing materials is: Wet -' , I 6. -Number of samples in shipping container:

'7. Sample holding times exceeded?

Yes [ j.8. Samples have:------tat...._.hazard labels--/-custody Seals -appropriate sample labels 9. Samples are: good condition

.-*.leaking-broken -have air bubbles 10. Were any anomalies identified in sample receipt? Yes [ No 1. .Description of anomalies (include sample numbers): Sample Cstodian/Lahoratory:

." Telephoned to: On By.. : " .... By.13 Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-OOI Figure 1. Sample Check-in List Date/Time Received: SDG#:-Work Order Number: Fl " \ " Shipping Cdntainer ID, 7 )"- 7 2"/ Q Chain of a-.-S/-1. Custody Seals oni shipping container intact?..

Yes t o[']o 2. Custody Seals dated and signed? Yes'p.No [ ,.3. Chain-of-Custody record present? Yes K" No [ ].4. Cooler temperature ."" 5. Vermiculite/packing materials is: Wet [.-br ]6.' Number of samples in shipping container:__'

7. Sample holding times exceeded?

Yes 8. Samples have: Ztape ....hazard labels_... custody seals -appropriate sample labels 9. Samples are:*i good condition -leaking broken ." have air bubbles 10. Were any anomalies identified in sample receipt? Yes [] No 11.. .Description of anomalies,(include sample numbers): Telephoned to: On By .14 RADIOLOGICAL ANALYSIS 15 Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)Work Order 170132 Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 562551 562335 562334 Sample ID 170132002 1201169377 1201169378 1201169379 1201169380 Client ID 9106-0001-121F Method Blank (MB)170125005(9522-0006-ASPHALT-0

15) Sample Duplicate (DUP)170125005(9522-0006-ASPHALT-O1
5) Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

16 Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170125005 (9522-0006-ASPHALT-015).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information 17 Product: Alphaspec Pu, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- 11-RC Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 562552 562335 562334 Sample ID 170132002 1201169381 1201169382 1201169383 1201169384 Client ID 9106-0001-121F Method Blank (MB)170125005(9522-0006-ASPHALT-0

15) Sample Duplicate (DUP)170125005(9522-0006-ASPHALT-015)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-011 REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170125005 (9522-0006-ASPHALT-015).

QC Information All of the QC samples met the required acceptance limits.18 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- 11-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 562553 Prep Batch Number: 562335 Dry Soil Prep GL-RAD-A-021 Batch Number: 562334 19 Sample ID Client ID 170132002 9106-0001-121F 1201169385 Method Blank (MB)1201169386 170125005(9522-0006-ASPHALT-015)

Sample Duplicate (DUP)1201169387 170125005(9522-0006-ASPHALT-0

15) Matrix Spike (MS)1201169388 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170125005 (9522-0006-ASPHALT-015).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this 20 SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analvyis Information Product: Analytical Method: Prep Method: Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep Analytical Batch Number: 562372 Prep Batch Number: 562337 Sample ID 170132022 170132023 170132024 170132025 170132026 170132027 170132028 170132029 170132030 170132031 1201168947 1201168948 1201168949 Client ID 9106-0001-106F 9106-0001-106FS 9106-0001-11 OF 9106-0001-109F 9106-0001-11 IF 9106-0001-122F 9106-0001-123F 9106-0001-124F 9106-0001-125F 9106-0001-126F Method Blank (MB)170125001 (9522-0006-ASPHALT-015)

Sample Duplicate (DUP)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 11.Calibration Information:

Calibration Information 21 All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170125001 (9522-0006-ASPHALT-O15).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information 22 Qualifier UI Reason Data rejected due to high peak-width.

Data rejected due to interference.

Data rejected due to low abundance.

UI UI Analyte Bismuth-212 Cobalt-60 Manganese-54 Actinium-228 Cesium-134 Cobalt-60 Sample 170132028 170132030 170132027 1201168948 170132028 170132029 170132024 Method/Analysis Information Product: Analytical Method: Prep Method: Analytical Batch Number: Prep Batch Number: Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep 562373 562334 23 Sample ID 170132001 170132003 170132004 170132005 170132006 170132007 170132008 170132009 170132010 170132011 170132012 170132013 170132014 170132015 170132016 170132017 170132018 170132019 170132020 170132021 1201168950 1201168951 1201168952 Client ID 9106-0001-121F 9106-0001-127F 9106-0001-128F 9106-0001-129F 9106-0001-130F 9106-0001-131F 9106-0001-133F 9106-0001-117F 9106-0001-117FS 9106-0001-113F 9106-0001-114F 9106-0001-116F 9106-0001-120F 9106-0001-104F 9106-0001-107F 9106-0001-115F 9106-0001-108F 9106-0001-119F 9106-0001-101F 9106-0001-103F Method Blank (MB)170132001(9106-0001-12 IF) Sample Duplicate (DUP)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-0 13 REV# 11.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170132001 (9106-0001-121F).

24 QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this'SDG.Additional Comments The relative percent difference between samples 1201168951 (9106-0001-121F) and 170132001 (9106-0001-121F) for TI-208 did not meet with in the duplication criteria.

However, when a relative error ratio, precision is shown at 2.45394.Qualifier information 25 Qualifier U'UI Reason Data rejected due to high counting uncertainty.

Data rejected due to high peak-width.

UI U'UI Data rejected due to interference.

Data rejected due to low abundance.

Data rejected due to no valid peak.Analyte Sample Bismuth-212 170132007 170132020 170132021 Cesium-137 170132006 Europium-155 170132003 170132006 170132009 170132010 170132018 Cesium-134 170132003 170132006 170132009 170132010 170132012 170132013 170132015 170132017 170132018 1201168951 Niobium-94 170132016 170132017 Silver-108m 170132019 Cobalt-60 170132006 Method/Analysis Information 26 Product: GFPC, Sr90, solid -0.025 pCi/g Analytical Method: EPA 905.0 Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 562545 562335 562334 Sample ID 170132001 1201169351 1201169352 1201169353 1201169354 Client ID 9106-0001-121F Method Blank (MB)170132001(9106-0001-12 IF) Sample Duplicate (DUP)170132001(9106-0001-121F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170132001 (9106-0001-121F).

QC Information All of the QC samples met the required acceptance limits.27 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS Analytical Method: Analytical Batch Number: Sample ID 170132002 1201169591 1201169592 1201169593 1201169594 DOE EML HASL-300, Tc-02-RC Modified 562651 Client ID 9106-0001-121F Method Blank (MB)170132002(9106-0001-121F)

Sample Duplicate (DUP)170132002(9106-0001-12 IF) Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.28 Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170132002 (9106-0001-121F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information 29 Product: Liquid Scint Fe55, Solid-ALL FSS Analytical Method: DOE RESL Fe-1, Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Ash Soil Prep Dry Soil Prep 562520 562335 Dry Soil Prep GL-RAD-A-021 Batch Number: 562334 Sample ID 170132002 1201169282 1201169283 1201169284 1201169285 Client ID 9106-0001-121F Method Blank (MB)170125007(9522-0006-ASPHALT-014)

Sample Duplicate (DUP)170125007(9522-0006-ASPHALT-014)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170125007 (9522-0006-ASPHALT-014).

QC Information All of the QC samples met the required acceptance limits.30 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: DOE RESL Ni-1, Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 562521 562335 562334 Sample ID 170132002 1201169286 1201169287 1201169288 1201169289 Client ID 9106-0001-121F Method Blank (MB)170125007(9522-0006-ASPHALT-014)

Sample Duplicate (DUP)170125007(9522-0006-ASPHALT-014)

Matrix Spike (MS)Laboratory Control Sample (LCS)31 SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170125007 (9522-0006-ASPHALT-014).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.32 Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: LSC, Tritium Dist, Solid -3 pCi/g Analytical Method: EPA 906.0 Modified Analytical Batch Number: 562518 Sample ID 170132001 1201169278 1201169279 1201169280 1201169281 Client ID 9106-0001-121F Method Blank (MB)170125003(9522-0006-ASPHALT-014)

Sample Duplicate (DUP)170125003(9522-0006-ASPHALT-014)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 13.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170125003 (9522-0006-ASPHALT-014).

QC Information All of the QC samples met the required acceptance limits.33 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Samples 1201169278 (MB), 1201169279 (9522-0006-ASPHALT-014) and 170132001 (9106-0001-12 IF) were recounted due to high MDAs.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

The following NCR was generated for this SDG: NCR 353427 was generated due to Container scanning event for custody missed. 1. Samples 170125001, 170125002, 170125003, 170125004, and 170132001 were not scanned into the batch prior to analysis.

Custody of the samples was maintained at all times. 1. Reporting results. The error has been corrected, and the analyst has been instructed on proper scanning procedure.

Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint C14, Solid AII,FSS Analytical Method: Analytical Batch Number: Sample ID 170132002 1201169290 1201169291 1201169292 1201169293 EPA EERF C-01 Modified 562522 Client ID 9106-0001-121F Method Blank (MB)170132002(9106-0001-12 IF) Sample Duplicate (DUP)170132002(9106-0001-12 IF) Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this 34 narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170132002 (9106-0001-121F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Certification Statement 35 Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator.

In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.The following data validator verified the information presented in this case narrative:

Reviewer/Date:

36 General Engineering Laboratories Form GEL-NCR Rev. 06/05 NCR Report No.: 353427 Revision No.: COMPANY -WIDE NONCONFORMANCE REPORT Mo.Day Yr. Division:

Quality Criteria:

Type: 31-AUG-06 Radiochemistry Specifications Process Instrument Type: Test / Method: Matrix Type: Client Code: LSC EPA 906.0 Modified Solid YANK Batch ID: Sample Numbers: 562518 See Below Potentially affected work order(s)(SDG):

170125(MSR#06-1155),170132(MSR#06-1156)

Application Issues: Container scanning event for custody missed Specification and Requirements NRG Disposition:

Nonconformance

==

Description:==

1. Samples 170125001, 170125002, 170125003, 170125004, and 1. Reporting results. The error has been corrected, and the analyst has 170132001 were not scanned into the batch prior to analysis.

Custody of been instructed on proper scanning procedure.

the samples was maintained at all times.Originator's Name: John Parker Quality Review: Director: Data Validator/Group Leader: 31-AUG-06 Melanie Aycock 01-SEP-06 Page 1 37 SAMPLE DATA

SUMMARY

38 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.Client SDG: MSR#06-1156 GEL Work Order: 170132 The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria** Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures.

Please direct any questions to your Project Manager, Cheryl Jones.Reviewed by 39 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Cprtifpirnft af Annilvgi.X.Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: 9106-0001-121F Project: YANKO1204 Sample ID: 170132001 Client ID: YANKOOI Matrix: SE Vol. Recv.: Collect Date: 03-AUG-06 Receive Date: 25-AUG-06 Collector:

Client Moisture:

23.5%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.940 Americium-241 U -0.0463 Bismuth-212 0.504 Bismuth-214 0.724 Cesium-134 U 0.0291 Cesium-137 0.743 Cobalt-60 0.627 Europium-152 U -0.00488 Europium-154 U 0.029 Europium-155 U 0.0447 Lead-212 0.941 Lead-214 0.858 Manganese-54 U 0.0142 Niobium-94 U 0.00021 Potassium-40 10.8 Radium-226 0.724 Silver-108m U -0.00568 Thallium-208 0.261 Rad Gas Flow Proportional Counting+/-0.143+/-0.0742+/-0.254+/-0.0757+/-0.032+/-0.0489+/-0.0612+/-0.0485+/-0.0513+/-0.0581+/-0.0572+/-0.0803+/-0.0214+/-0.0166+/-0.700+/-0.0757+/-0.0162+/-0.0377 0.0524 0.061 0.117 0.0291 0.02 11 0.0145 0.013 0.0407 0.0464 0.0384 0.0226 0.0286 0.0168 0.0143 0.106 0.0291 0.0142 0.016+/-0.143+/-0.0742+/-0.254+/-0.0757+/-0.032+/-0.0489+/-0.0612+/-0.0485+/-0.0513+/-0.0581+/-0.0572+/-0.0803+/-0.0214+/-0.0166+/-0.700+/-0.0757+/-0.0162+/-0.0377 0.111 0.125 0.247 0.0609 0.0441 0.0306 0.0286 0.0844 0.0997 0.0789 0.0466 0.0594 0.0354 0.0299 0.238 0.0609 0.0295 0.0334 0.0185 2.58 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH 1 08/28/06 2336 562373 1 GFPC, SO9O, solid -0.025 pCi/g Strontium-90 U 0.0 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid -3 pCi/g Tritium U 0389 +/-0.0104 0.00841 +/-0.0104 1.29 +/-1.53 1.17 +/-1.53 KSDI 08/30/06 1844 562545 2 DFAI 08/31/06 1221 562518 3 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM1 08/25/06 1557 562334 The following Analytical Methods were performed Method Description 40 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-121F Proiect: YANKO1204 Sample ID: 170132001 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified 3 EPA 906.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid -0.025 pCi/g 84 (25%-/125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.41 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-121F 170132002 SE 03-AUG-06 25-AUG-06 Client 23.5%Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 Curium-242 U -Curium-243/244 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U (Plutonium-239/240 U -Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U Rad Liquid Scintillation Analysis Liquid Scint C14, SolidAILFSS Carbon-14 Liquid Scint Fe55, Solid-ALL FSS lron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U C 0.861-0.0089 0.433+/-0.333+/-0.0174+/-0.250 0.0504 0.0333 0.0772+/-0.351+/-0.0175+/-0.256 0.00157 +/-0.0855 0.0706 +/-0.0855-0.0566 +/-0.0894 0.0864 +/-0.0894-6.93 +/-13.0 11.2 +/-13.0 0.155 +/-0.0912 0.0686 +/-0.0912 51.5 +/-52.6 34.0 +/-52.7 4.91 +/-7.64 6.30 +/-7.64 1.00437 +/-0.175 0.146 +/-0.175 0.189 0.167 0.243 0.248 0.279 23.4 0.145 70.7 12.9 0.300 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g DDRI 09/03/06 1211 562551 1 DDRI 09/03/06 1206 562552 2*DDRI 09/06/06 1618 562553 3 AXD2 08/30/06 0307 562522 4 MXPI 09/01/06 1903 562520 5 MXPI 09/01/06 0320 562521 6 KXR1 09/02/06 1207 562651 7 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXMI 08/25/06 1557 562334 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 3 4 5 6 7 DOE EML HASL-300, Pu-I 1-RC Modified DOE EML HASL-300, Pu-11-RC Modified EPA EERF C-01 Modified DOE RESL Fe-I, Modified DOE RESL Ni-i, Modified DOE EML HASL-300, Tc-02-RC Modified 42 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: Sample ID: 9106-0001-121F 170132002 Proiect: YANK01204 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Test Recovery%

Acceptable Limits Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 76 49 90 65 84 80 (15%-125%)

(15%/6-1250/6)

(25%- 125%)(15%-125%)

(25%-I125%/.)

(15%/o-125%/.)

Notes: The Qualifiers in this report are defined as follows A A A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.43 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-127F 170132003 SE 01-AUG-06 25-AUG-06 Client 16%Proiect: YANKO 1204 Client ID: YANKO0I Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.848 +/-0.170 Americium-241 U 0.0252 +/-0.0326 Bismuth-212 0.657 +/-0.311 Bismuth-214 0.729 +/-0.0884 Cesium- 134 UI 0.00 +/-0.039 Cesium- 137 0.478 +/-0.0432 Cobalt-60 0.786 +/-0.0635 Europium-152 U -0.00832 +/-0.0462 Europium-154 U 0.0439 +/-0.056 Europium-155 UI 0.00 +/-0.0708 Lead-212 0.947 +/-0.0548 Lead-214 0.817 +/-0.0803 Manganese-54 U 0.0273 +/-0.0257 Niobium-94 U -0.00739 +/-0.019 Potassium-40 10.5 +/-0.707 Radium-226 0.729 +/-0.0884 Silver-108m U -0.0162 +/-0.0161 Thallium-208 0.301 +/-0.0409 0.0681 0.0218 0.126 0.0298 0.0225 0.0182 0.0161 0.0412 0.0502 0.0367 0.0224 0.0281 0.0176 0.0156 0.138 0.0298 0.0135 0.0162+/-0.170+/-0.0326+/-0.311+/-0.0884+/-0.039+/-0.0432+/-0.0635+/-0.0462+/-0.056+/-0.0708+/-0.0548+/-0.0803+/-0.0257+/-0.019+/-0.707+/-0.0884+/-0.0161+/-0.0409 0.143 0.0445 0.265 0.0624 0.0468 0.0379 0.0346 0.0852 0.107 0.0751 0.046 0.0584 0.0368 0.0327 0.301 0.0624 0.0281 0.0339 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 08/28/06 2336 562373 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXMI 08/25/06 1557 562334 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 44 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-127F Project: YANK01204 Sample ID: 170132003 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.45 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Project: YANKO 1204 Client ID: YANKOOI Vol. Recv.: Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-128F 170132004 SE 01-AUG-06 25-AUG-06 Client 23.7%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.03 +/-0.175 Americium-241 U 0.0227 +/-0.0297 Bismuth-212 0.484 +/-0.256 Bismuth-214 0.732 +/-0.0823 Cesium-134 U 0.032 +/-0.0345 Cesium-137 0.850 +/-0.0592 Cobalt-60 0.818 +/-0.0581 Europium-152 U -0.0101 +/-0.0473 Europium-154 U 0.00382 +/-0.0554 Europium-155 U 0.0371 +/-0.0419 Lead-212 0.982 +/-0.0559 Lead-214 0.822 +/-0.0761 Manganese-54 U 0.003 +/-0.020 Niobium-94 U 0.0111 +/-0.0179 Potassium-40 11.8 +/-0.779 Radium-226 0.732 +/-0.0823 Silver-108m U 0.00397 +/-0.0168 Thallium-208 0.316 +/-0.0465 0.0612 0.0233 0.138 0.030 0.0226 0.0157 0.0151 0.0424 0.0471 0.0394 0.023 0.0302 0.0178 0.0157 0.134 0.030 0.015 0.0151+/-0.175+/-0.0297+/-0.256+/-0.0823+/-0.0345+/-0.0592+/-0.0581+/-0.0473+/-0.0554+/-0.0419+/-0.0559+/-0.0761+/-0.020+/-0.0179+/-0.779+/-0.0823+/-0.0168+/-0.0465 0.129 0.0475 0.288 0.0625 0.047 0.0329 0.0325 0.0875 0.100 0.0805 0.0472 0.0624 0.0373 0.0328 0.292 0.0625 0.0311 0.0316 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 08/29/06 0457 562373 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXMI 08/25/06 1557 562334 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 46 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-128F Project: YANK01204 Sample ID: 170132004 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldo 1-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.47 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-129F 170132005 SE 07-AUG-06 25-AUG-06 Client 12.2%Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.701 U 0.00649 0.557 0.717 U 0.044 0.061 U -0.0033 U -0.0226 U -0.00152 U 0.0851 0.750 0.753 U 0.0115 U 0.0013 12.1 0.717 U -0.00081 0.269+/-0.197+/-0.0351+/-0.324+/-0.109+/-0.0348+/-0.0496+/-0.0253+/-0.0599+/-0.0846+/-0.0996+/-0.0729+/-0.0882+/-0.0268+/-0.0218+/-0.864+/-0.109+/-0.0188+/-0.0566 0.0708 0.028 0.152 0.0374 0.0259 0.0202 0.0208 0.0492 0.061 0.0432 0.0345 0.0361 0.0227 0.0183 0.197 0.0374 0.0165 0.020+/-0.197+/-0.0351+/-0.324+/-0.109+/-0.0348+/-0.0496+/-0.0253+/-0.0599+/-0.0846+/-0.0996+/-0.0729+/-0.0882+/-0.0268+/-0.0218+/-0.864+/-0.109+/-0.0188+/-0.0566 0.149 0.0572 0.319 0.0779 0.054 0.0422 0.0445 0.102 0.130 0.0885 0.0706 0.0747 0.0474 0.0384 0.422 0.0779 0.0343 0.0417 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 08/29/06 0702 562373 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM1 08/25/06 1557 562334 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 48 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-129F Proiect: YANK01204 Sample ID: 170132005 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.49 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-130F 170132006 SE 01-AUG-06 25-AUG-06 Client 14.1%Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamina, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.952 +/-0.128 Americium-241 U -0.0124 +/-0.019 Bismuth-212 0.596 +/-0.191 Bismuth-214 0.747 +/-0.0748 Cesium-134 UI 0.00 +/-0.0362 Cesium-137 Ui 0.00 +/-0.0192 Cobalt-60 UI 0.00 +/-0.0261 Europium-152 U 0.0176 +/-0.0349 Europium-154 U 0.0194 +/-0.0433 Europium-155 UI 0.00 +/-0.0481 Lead-212 0.886 +/-0.043 Lead-214 0.839 +/-0.0578 Manganese-54 U 0.0174 +/-0.0177 Niobium-94 U 0.0185 +/-0.0134 Potassium-40 10.2 +/-0.600 Radium-226 0.747 +/-0.0748 Silver-108m U -0.00797 +/-0.0121 Thallium-208 0.311 +/-0.0331 0.0454 0.0169 0.102 0.0217 0.0177 0.0129 0.0162 0.031 0.0382 0.027 0.0178 0.0224 0.0126 0.0124 0.117 0.0217 0.0106 0.0112+/-0.128+/-0.019+/-0.191+/-0.0748+/-0.0362+/-0.0192+/-0.0261+/-0.0349+/-0.0433+/-0.0481+/-0.043+/-0.0578+/-0.0177+/-0.0134+/-0.600+/-0.0748+/-0.0121+/-0.0331 0.0959 0.0346 0.214 0.0456 0.037 0.0271 0.0343 0.0642 0.0817 0.0555 0.0367 0.0464 0.0266 0.026 0.254 0.0456 0.0221 0.0236 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 08/29/06 0702 562373 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXMI 08/25/06 1557 562334 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 50 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-130F Project: YANKO 1204 Sample ID: 170132006 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.51 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certifleate.

of Ani-d's Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-131F 170132007 SE 07-AUG-06 25-AUG-06 Client 16.3%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.762 +/-0.229 Americium-241 U 0.0168 +/-0.0333 Bismuth-212 Ul 0.00 +/-0.430 Bismuth-214 0.670 +1-0.105 Cesium-134 U 0.0558 +/-0.0362 Cesium-137 0.566 +/-0.0691 Cobalt-60 0.258 +/-0.0709 Europium-152 U 0.0317 +/-0.0576 Europium-154 U -0.0547 +/-0.0703 Europium-155 U 0.0667 +/-0.0646 Lead-212 0.814 +/-0.0651 Lead-214 0.731 +1-0.105 Manganese-54 U 0.00911 +/-0.0281 Niobium-94 U 0.0199 +/-0.0266 Potassium-40 9.45 +/-0.974 Radium-226 0.670 +/-0.105 Silver-108m U -0.00604 +/-0.0218 Thallium-208 0.260 +/-0.0608 0.0761 0.0326 0.163 0.0418 0.0299 0.0212 0.0231 0.0542 0.0542 0.0485 0.0285 0.0395 0.0244 0.0216 0.202 0.0418 0.0192 0.0223+/-0.229+/-0.0333+/-0.430+/-0.105+/-0.0362+/-0.0691+/-0.0709+/-0.0576+/-0.0703+/-0.0646+/-0.0651+1-0.105+/-0.0281+/-0.0266+/-0.974+/-0.105+/-0.0218+/-0.0608 0.164 0.0669 0.349 0.0885 0.0632 0.0452 0.0507 0.114 0.121 0.100 0.0594 0.0826 0.0519 0.0458 0.450 0.0885 0.0405 0.0473 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 08/29/060721 562373 1 The following Prep Methods were performed Method Description Dry Soil Prep Dry Soil Prep GL-RAD-A-021 Analyst Date Time Prep Batch LXM I 08/25/06 1557 562334 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 52 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-131F Proiect: YANK01204 Sample ID: 170132007 Client ID: YANKOOl Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.Ul Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.53 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-133F 170132008 SE 08-AUG-06 25-AUG-06 Client 24.7%Project: YANKO 1204 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gammna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.960 +/-0.222 Americium-241 U 0.0263 +/-0.0493 Bismuth-212 0.750 +/-0.290 Bismuth-214 0.697 +/-0.108 Cesium- 134 U 0.0398 +/-0.0419 Cesium-137 0.608 +/-0.0796 Cobalt-60 0.784 +/-0.083 Europium-152 U -0.0146 +/-0.0549 Europium-154 U -0.0185 +/-0.0601 Europium-155 U 0.0575 +/-0.0533 Lead-212 0.921 +/-0.0972 Lead-214 0.834 +/-0.123 Manganese-54 U 0.00563 +/-0.0225 Niobium-94 U-0.000437

+/-0.0184 Potassium-40 11.9 +/-1.08 Radium-226 0.697 +/-0.108 Silver-108m U 0.008 +/-0.0201 Thallium-208 0.264 +/-0.0577 0.0697 0.0448 0.165 0.0358 0.0255 0.0195 0.0166 0.0471 0.0477 0.0478 0.028 0.0333 0.0199 0.0161 0.145 0.0358 0.0176 0.0184+/-0.222+/-0.0493+/-0.290+/-0.108+/-0.0419+/-0.0796+/-0.083+/-0.0549+/-0.0601+/-0.0533+/-0.0972+/-0.123+/-0.0225+/-0.0184+/-1.08+/-0.108+/-0.0201+/-0.0577 0.148 0.0923 0.348 0.0754 0.0536 0.0411 0.0366 0.0985 0.105 0.0986 0.0579 0.0697 0.0422 0.0342 0.323 0.0754 0.0368 0.0389 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH 1 08/29/06 0722 562373 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXMI 08/25/06 1557 562334 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 54 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-133F Project: YANKO1204 Sample ID: 170132008 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.55 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-117F 170132009 SE 03-AUG-06 25-AUG-06 Client 16.1%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowih Waived Actinium-228 0.854 +/-0.122 Americium-241 U 0.00795 +/-0.0589 Bismuth-212 0.586 +/-0.288 Bismuth-214 0.685 +/-0.0696 Cesium-134 UI 0.00 +/-0.026 Cesium-137 U 0.0138 +/-0.0176 Cobalt-60 U 0.000525 +/-0.0153 Europium-152 U 0.00368 +/-0.0435 Europium-154 U -0.00778 +/-0.0434 Europium-155 UI 0.00 +/-0.0763 Lead-212 0.791 +/-0.0539 Lead-214 0.772 +/-0.0754 Manganese-54 U 0.00517 +/-0.0151 Niobium-94 U 0.000367 +/-0.0135 Potassium-40 10.1 +/-0.622 Radium-226 0.685 +/-0.0696 Silver-108m U 0.00923 +/-0.0134 Thallium-208 0.260 +/-0.0364 0.0425 0.0551 0.100 0.0288 0.0166 0.0127 0.0128 0.0342 0.0355 0.0427 0.0224 0.0251 0.0134 0.0119 0.105 0.0288 0.0121 0.0127+/-0.122+/-0.0589+/-0.288+/-0.0696+/-0.026+/-0.0176+/-0.0153+/-0.0435+/-0.0434+/-0.0763+/-0.0539+/-0.0754+/-0.0151+/-0.0135+/-0.622+/-0.0696+/-0.0134+/-0.0364 0.0907 0.113 0.212 0.0601 0.0348 0.0268 0.0276 0.0715 0.0768 0.0879 0.0462 0.0524 0.0284 0.0251 0.230 0.0601 0.0254 0.0267 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 08/29/06 0722 562373 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXMI 08/25/06 1557 562334 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 56 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-117F Project: YANK01204 Sample ID: 170132009 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.57 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-1 17FS 170132010 SE 03-AUG-06 25-AUG-06 Client 15.1%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANKO0 I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.863 Americium-241 U -0.0492 Bismuth-212 0.589 Bismuth-214 0.643 Cesium-134 UI 0.00 Cesium-137 U 0.00646 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver- 108m Thallium-208 U 0.00392 U -0.0139 U -0.0529 UI 0.00 0.783 0.748 U 0.018 U 0.00153 10.3 0.643 U 0.0105 0.256+/-0.148+/-0.101+/-0.197+/-0.0878+/-0.028+/-0.034+/-0.0134+/-0.0379+/-0.0464+/-0.0713+/-0.0865+/-0.0985+/-0.0197+/-0.0125+/-0.895+/-0.0878+/-0.0116+/-0.0371 0.0411 0.087 0.0809 0.0222 0.0151 0.0116 0.0117 0.0318 0.0358 0.0376 0.0186 0.0234 0.0115 0.0108 0.107 0.0222 0.0109 0.0124+/-0.148+/-0.101+/-0.197+/-0.0878+/-0.028+/-0.034+/-0.0134+/-0.0379+/-0.0464+/-0.0713+/-0.0865+/-0.0985+/-0.0197+/-0.0125+/-0.895+/-0.0878+/-0.0116+/-0.0371 0.0867 0.179 0.171 0.0462 0.0315 0.0243 0.0252 0.0659 0.0765 0.077 0.0382 0.0485 0.0243 0.0225 0.233 0.0462 0.0226 0.0258 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH 1 08/29/06 0734 562373 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXMI 08/25/06 1557 562334 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 58 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-117FS Project: YANK01204 Sample ID: 170132010 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.59 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Ct-rtifieatP of Annlvedi%Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: 9106-0001-113F Proiect: YANK01204 Sample ID: 170132011 Client ID: YANK001 Matrix: SE Vol. Recv.: Collect Date: 03-AUG-06 Receive Date: 25-AUG-06 Collector:

Client Moisture:

14.9%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GammaSolid-FSS 6AM & ALL FSS 226 Ingrowth Waived Actinium-228 0.761 +/-0.200 Americium-241 U 0.0461 +/-0.0416 Bismuth-212 0.611 +/-0.344 Bismuth-214 0.767 +/-0.144 Cesium-134 U 0.027 +/-0.0425 Cesium-137 0.387 +/-0.0685 Cobalt-60 0.259 +/-0.0727 Europium-152 U -0.119 +/-0.130 Europium-154 U 0.000805 +/-0.0891 Europium-155 U 0.0487 +/-0.066 Lead-212 0.850 +/-0.0977 Lead-214 0.792 +/-0.144 Manganese-54 U 0.00206 +/-0.0321 Niobium-94 U 0.016 +/-0.0263 Potassium-40 10.7 +/-1.02 Radium-226 0.767 +/-0.144 Silver-108m U -0.0206 +/-0.0314 Thallium-208 0.307 +/-0.0628 0.0898 0.0349 0.185 0.0444 0.0308 0.025 0.0258 0.0576 0.075 0.0559 0.0318 0.0417 0.0281 0.0242 0.189 0.0444 0.0224 0.0263+/-0.200+/-0.0416+/-0.344+/-0.144+/-0.0425+/-0.0685+/-0.0727+/-0.130+/-0.0891+/-0.066+/-0.0977+/-0.144+/-0.0321+/-0.0263+/-1.02+/-0.144+/-0.0314+/-0.0628 0.179 0.0697 0.371 0.0888 0.0616 0.0499 0.0517 0.115 0.150 0.112 0.0636 0.0833 0.0561 0.0483 0.378 0.0888 0.0448 0.0527 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH 1 08/29/06 0739 562373 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM I 08/25/06 1557 562334 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 60 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-113F Project: YANK01204 Sample ID: 170132011 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.61 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-114F 170132012 SE 03-AUG-06 25-AUG-06 Client 20.3%Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.722 +/-0.127 Americium-241 U -0.0207 +/-0.0659 Bismuth-212 0.434 +/-0.239 Bismuth-214 0.545 +/-0.0769 Cesium-134 UI 0.00 +/-0.0243 Cesium-137 0.793 +/-0.0493 Cobalt-60 0.370 +/-0.0518 Europium-152 U -0.0119 +/-0.044 Europium-154 U -0.00625 +/-0.048 Europium-155 U 0.00 +/-0.0492 Lead-212 0.776 +/-0.0533 Lead-214 0.644 +/-0.0632 Manganese-54 U 0.00559 +/-0.0161 Niobium-94 U -0.00431 +/-0.0137 Potassium-40 10.6 +/-0.695 Radium-226 0.545 +/-0.0769 Silver-108m U 0.00137 +/-0.0144 Thallium-208 0.214 +/-0.032 0.0422 0.0547 0.115 0.0249 0.0168 0.0134 0.0108 0.0339 0.0396 0.0462 0.0217 0.0291 0.0143 0.0119 0.108 0.0249 0.0127 0.0141+/-0.127+/-0.0659+/-0.239+/-0.0769+/-0.0243+/-0.0493+/-0.0518+/-0.044+/-0.048+/-0.0492+/-0.0533+/-0.0632+/-0.0161+/-0.0137+/-0.695+/-0.0769+/-0.0144+/-0.032 0.0901 0.113 0.240 0.0522 0.0353 0.0282 0.0238 0.0707 0.0848 0.095 0.0448 0.0603 0.0302 0.0251 0.235 0.0522 0.0265 0.0296 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 08/29/06 1045 562373 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXMI 08/25/06 1557 562334 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 62 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-114F Proiect: YANKO 1204 Sample ID: 170132012 ClientID:

YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.63 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-116F 170132013 SE 03-AUG-06 25-AUG-06 Client 12.1%Proiect: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.756 +/-0.134 Americium-241 U 0.0108 +/-0.0922 Bismuth-212 U 0.289 +/-0.343 Bismuth-214 0.577 +/-0.100 Cesium-134 UI 0.00 +/-0.0373 Cesium-137 U 0.0138 +/-0.0209 Cobalt-60 U 0.0326 +/-0.0229 Europium-152 U -0.0074 +/-0.0561 Europium-154 U 0.0116 +/-0.0608 Europium-155 U 0.00 +/-0.0517 Lead-212 0.706 +/-0.0606 Lead-214 0.676 +/-0.108 Manganese-54 U 0.0262 +/-0.0271 Niobium-94 U 0.00164 +/-0.020 Potassium-40 9.32 +/-0.927 Radium-226 0.577 +/-0.100 Silver-108m U 0.00992 +/-0.0183 Thallium-208 0.189 +/-0.044 0.0493 0.0769 0.153 0.0315 0.0241 0.0193 0.0228 0.0485 0.0539 0.0518 0.028 0.0335 0.0152 0.0176 0.168 0.0315 0.0163 0.0194+/-0.134+/-0.0922+/-0.343+/-0.100+/-0.0373+/-0.0209+/-0.0229+/-0.0561+/-0.0608+/-0.0517+/-0.0606+/-0.108+/-0.0271+/-0.020+/-0.927+/-0.100+/-0.0183+/-0.044 0.109 0.159 0.326 0.0674 0.0513 0.0411 0.0496 0.102 0.119 0.107 0.0582 0.0705 0.0331 0.0375 0.377 0.0674 0.0345 0.0412 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHl 08/29/06 1103 562373 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXMI 08/25/06 1557 562334 The following Analytical Methods were performed Method Description I EML FIASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 64 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-116F Project: YANK01204 Sample ID: 170132013 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.65 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-120F 170132014 SE 03-AUG-06 25-AUG-06 Client 19.8%Proiect: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver- 108m Thallium-208 1.05 U -0.0753 0.597 0.760 U 0.0284 0.739 0.708 U 0.00273 U -0.061 U 0.0174 0.967 0.934 U 0.0104 U 0.0223 11.7 0.760 U 0.00417 0.323+/-0.200+/-0.124+/-0.357+/-0.118+/-0.0315+/-0.0787+/-0.0781+/-0.0478+/-0.0547+/-0.0551+/-0.0943+/-0.118+/-0.0201+/-0.0168+/- 1.03+/-0.118+/-0.0167+/-0.045 0.057 0.0937 0.120 0.0287 0.0199 0.0162 0.0152 0.0411 0.0411 0.0471 0.023 0.0278 0.0177 0.0153 0.118 0.0287 0.0143 0.0141+/-0.200+/-0.124+/-0.357+/-0.118+/-0.0315+/-0.0787+/-0.0781+/-0.0478+/-0.0547+/-0.0551+/-0.0943+/-0.118+/-0.0201+/-0.0168+/-1.03+/-0.118+/-0.0167+/-0.045 0.119 0.191 0.251 0.0597 0.0415 0.0337 0.0325 0.0847 0.0879 0.0961 0.0473 0.0575 0.0368 0.0319 0.258 0.0597 0.0295 0.0295 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH-l1 08/29/06 1104 562373 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXMI 08/25/06 1557 562334 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 66 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-120F Project: YANKO 1204 Sample ID: 170132014 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.67 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Project: YANK0 1204 Client ID: YANK001 Vol. Recv.: Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-104F 170132015 SE 08-AUG-06 25-AUG-06 Client 11.9%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.644 +/-0.143 Americium-241 U -0.15 +/-0.095 Bismuth-212 0.646 +/-0.228 Bismuth-214 0.446 +/-0.067 Cesium-134 UI 0.00 +/-0.0237 Cesium-137 0.289 +/-0.0526 Cobalt-60 U 0.0315 +/-0.0262 Europium-152 U -0.0171 +/-0.0524 Europium-154 U -0.0153 +/-0.0591 Europium-155 U 0.00 +/-0.0552 Lead-212 0.668 +/-0.0532 Lead-214 0.476 +/-0.0773 Manganese-54 U 0.0279 +/-0.0165 Niobium-94 U 0.00824 +/-0.0167 Potassium-40 9.62 +/-0.738 Radium-226 0.446 +/-0.067 Silver-108m U -0.00821 +/-0.0194 Thallium-208 0.187 +/-0.0448 0.0561 0.0754 0.116 0.0342 0.0208 0.0161 0.0172 0.045 0.0479 0.0551 0.0285 0.0322 0.0155 0.0153 0.145 0.0342 0.0139 0.0163+/-0.143+/-0.095+/-0.228+/-0.067+/-0.0237+/-0.0526+/-0.0262+/-0.0524+/-0.0591+/-0.0552+/-0.0532+/-0.0773+/-0.0165+/-0.0167+/-0.738+/-0.067+/-0.0194+/-0.0448 0.121 0.155 0.249 0.0721 0.0441 0.0342 0.0377 0.0942 0.105 0.113 0.0588 0.0674 0.0332 0.0324 0.323 0.0721 0.0294 0.0346 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 08/29/06 1105 562373 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM1 08/25/06 1557 562334 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 68 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-104F Project: YANK01204 Sample ID: 170132015 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.69 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-107F 170132016 SE 08-AUG-06 25-AUG-06 Client 16.5%Project: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Ganima,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.875 +/-0.197 Americium-241 U -0.141 +/-0.107 Bismuth-212 0.861 +/-0.481 Bismuth-214 0.543 +/-0.0961 Cesium-134 U 0.00 +/-0.0409 Cesium-137 0.695 +/-0.0741 Cobalt-60 0.246 +/-0.0507 Europium-152 U 0.0178 +/-0.0651 Europium-154 U 0.0182 +/-0.0767 Europium-155 U 0.00 +/-0.0629 Lead-212 0.856 +/-0.0734 Lead-214 0.739 +/-0.0994 Manganese-54 U 0.0111 +/-0.0307 Niobium-94 UI 0.00 +/-0.0272 Potassium-40 11.2 +/-0.933 Radium-226 0.543 +/-0.0961 Silver-108m U 0.000917 +/-0.0226 Thallium-208 0.251 +/-0.0525 0.0826 0.0807 0.157 0.0453 0.0254 0.0199 0.0231 0.0569 0.0664 0.0568 0.0331 0.0406 0.0233 0.020 0.151 0.0453 0.0191 0.0207+/-0.197+/-0. 107+/-0.481+/-0.0961+/-0.0409+/-0.0741+/-0.0507+/-0.0651+/-0.0767+/-0.0629+/-0.0734+/-0.0994+/-0.0307+/-0.0272+/-0.933+/-0.0961+/-0.0226+/-0.0525 0.177 0.167 0.336 0.0953 0.0542 0.0426 0.0508 0.119 0.145 0.118 0.0687 0.0851 0.0496 0.0425 0.348 0.0953 0.0403 0.0439 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 08/29/06 1251 562373 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM1 08/25/06 1557 562334 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 70 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-107F Project: YANK01204 Sample ID: 170132016 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.71 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-115F 170132017 SE 08-AUG-06 25-AUG-06 Client 25.1%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnnia,Solid FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.772 +/-0.186 Americium-241 U 0.0775 +/-0.0941 Bismuth-212 0.765 +/-0.300 Bismuth-214 0.621 +/-0.108 Cesium-134 UI 0.00 +/-0.0437 Cesium-137 0.760 +/-0.0771 Cobalt-60 0.597 +/-0.0718 Europium-152 U 0.0063 +/-0.0603 Europium-154 U 0.0188 +/-0.0736 Europium-155 U 0.00 +/-0.063 Lead-212 0.782 +/-0.0699 Lead-214 0.791 +/-0.0962 Manganese-54 U 0.0156 +/-0.0252 Niobium-94 UI 0.00 +/-0.0338 Potassium-40 12.5 +/-0.997 Radium-226 0.621 +/-0.108 Silver-108m U 0.00503 +/-0.0205 Thallium-208 0.257 +/-0.0561 0.0701 0.088 0.177 0.0362 0.0285 0.0197 0.0199 0.0534 0.0633 0.0563 0.0292 0.039 0.0224 0.0219 0.217 0.0362 0.018 0.0212+/-0.186+/-0.0941+/-0.300+/-0. 108+/-0.0437+/-0.0771+/-0.0718+/-0.0603+/-0.0736+/-0.063+/-0.0699+/-0.0962+/-0.0252+/-0.0338+/-0.997+/-0.108+/-0.0205+/-0.0561 0.151 0.182 0.375 0.0768 0.060 0.0419 0.0438 0.112 0.137 0.116 0.0607 0.0816 0.0475 0.0462 0.474 0.0768 0.0379 0.0449 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 08/29/06 1251 562373 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXMI 08/25/06 1557 562334 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 72 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-115F Proiect: YANK01204 Sample ID: 170132017 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.73 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-108F 170132018 SE 07-AUG-06 25-AUG-06 Client 13.8%Proiect: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.04 +/-0.246 Americium-241 U 0.0106 +/-0.0417 Bismuth-212 0.539 +/-0.378 Bismuth-214 0.857 +/-0.129 Cesium-134 UI 0.00 +/-0.0364 Cesium-137 U 0.0207 +/-0.0385 Cobalt-60 U 0.017 +/-0.028 Europium-152 U 0.00148 +/-0.0661 Europium-154 U 0.0537 +/-0.0799 Europium-155 UI 0.00 +/-0.0809 Lead-212 0.721 +/-0.0888 Lead-214 0.887 +/-0.116 Manganese-54 U 0.0278 +/-0.0333 Niobium-94 U -0.00411 +/-0.025 Potassium-40 10.7 +/-0.925 Radium-226

ý0.857 +/-0.129 Silver-108m U -0.00713 +/-0.0237 Thallium-208 0.299 +/-0.0688 0.0835 0.0342 0.202 0.0427 0.0326 0.0235 0.025 0.0559 0.0718 0.0549 0.0417 0.0438 0.0293 0.021 0.203 0.0427 0.0207 0.0231+/-0.246+/-0.0417+/-0.378+/-0.129+/-0.0364+/-0.0385+/-0.028+/-0.0661+/-0.0799+/-0.0809+/-0.0888+/-0.116+/-0.0333+/-0.025+/-0.925+/-0.129+/-0.0237+/-0.0688 0.179 0.0703 0.427 0.0902 0.0687 0.0498 0.0544 0.117 0.155 0.113 0.0858 0.0915 0.0618 0.0445 0.450 0.0902 0.0435 0.0487 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 08/29/06 1251 562373 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXMI 08/25/06 1558 562334 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 74 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-108F Project: YANK01204 Sample ID: 170132018 Client ID: YANKOOl Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.75 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-119F 170132019 SE 07-AUG-06 25-AUG-06 Client 13.5%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANKOO I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date .Time Batch Mtd Rad Gamma Spec Analysis Gammna,Solid-FSS GAA4 & ALL FSS 226 Ingrowth Waived Actinium-228 0.519 +/-0.162 Americium-241 U 0.00832 +/-0.0234 Bismuth-212 0.334 +/-0.225 Bismuth-214 0.421 +/-0.0823 Cesium-134 U 0.00 +/-0.0292 Cesium-137 0.220 +/-0.0394 Cobalt-60 0.112 +/-0.0464 Europium-152 U 0.00995 +/-0.0455 Europium-154 U 0.035 +/-0.0546 Europium-155 U 0.00 +/-0.0357 Lead-212 0.547 +/-0.0471 Lead-214 0.553 +/-0.0721 Manganese-54 U -0.0173 +/-0.0198 Niobium-94 U 0.00613 +/-0.0168 Potassium-40 8.91 +/-0.798 Radium-226 0.421 +/-0.0823 Silver-108m UI 0.00 +/-0.0227 Thallium-208 0.158 +/-0.0348 0.0585 0.021 0.138 0.030 0.021 0.0169 0.0153 0.0393 0.0498 0.035 0.0205 0.0262 0.0151 0.0148 0.110 0.030 0.0128 0.0157+/-0.162+/-0.0234+/-0.225+/-0.0823+/-0.0292+/-0.0394+/-0.0464+/-0.0455+/-0.0546+/-0.0357+/-0.0471+/-0.0721+/-0.0198+/-0.0168+/-0.798+/-0.0823+/-0.0227+/-0.0348 0.127 0.0435 0.295 0.064 0.0447 0.0361 0.0343 0.0828 0.110 0.0726 0.0428 0.0555 0.0327 0.0316 0.258 0.064 0.0273 0.0334 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 08/29/06 1252 562373 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM1 08/25/06 1558 562334 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 76 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-119F Project: YANKO1204 Sample ID: 170132019 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.77 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-1OIF 170132020 SE 31-JUL-06 25-AUG-06 Client 12.4%Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.678 +/-0.206 Americium-241 U 0.0343 +/-0.0373 Bismuth-212 UI 0.00 +/-0.589 Bismuth-214 0.547 +/-0.117 Cesium-134 U 0.00 +/-0.058 Cesium-137 0.504 +/-0.0828 Cobalt-60 U 0.0128 +/-0.028 Europium-152 U -0.0402 +/-0.0953 Europium-154 U 0.0507 +/-0.0898 Europium-155 U 0.00 +/-0.0541 Lead-212 0.624 +/-0.0796 Lead-214 0.609 +/-0.110 Manganese-54 U -0.0178 +/-0.0251 Niobium-94 U 0.0296 +/-0.0262 Potassium-40 9.59 +/-0.982 Radium-226 0.547 +/-0.117 Silver-108m U -0.00266 +/-0.0226 Thallium-208 0.184 +/-0.0512 0.0548 0.0312 0.153 0.0382 0.033 0.0213 0.025 0.0544 0.0803 0.0495 0.0335 0.0384 0.0203 0.0248 0.229 0.0382 0.0195 0.0203+/-0.206+/-0.0373+/-0.589+/-0.117+/-0.058+/-0.0828+/-0.028+/-0.0953+/-0.0898+1-0.0541+/-0.0796+/-0.110+/-0.0251+/-0.0262+/-0.982+/-0.117+/-0.0226+/-0.0512 0.110 0.0624 0.305 0.0763 0.0659 0.0426 0.0499 0.109 0.161 0.0989 0.067 0.0767 0.0405 0.0495 0.457 0.0763 0.039 0.0406 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI1 08/29/06 1304 562373 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXMI 08/25/06 1558 562334 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 78 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-101F Project: YANK01204 Sample ID: 170132020 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.79 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Report Date: September 7, 2006 Project: Soils PO# 002332 Client Sample ID: 9106-0001-103F Project: YANK01204 Sample ID: 170132021 Client ID: YANK001 Matrix: SE Vol. Recv.: Collect Date: 31-JUL-06 Receive Date: 25-AUG-06 Collector:

Client Moisture:

17.4%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gammna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.574 +/-0.146 Americium-241 U 0.0403 +/-0.113 Bismuth-212 UI 0.00 +/-0.360 Bismuth-214 0.372 +/-0.0778 Cesium-134 U 0.00 +/-0.0251 Cesium-137 0.909 +/-0.0585 Cobalt-60 0.414 +/-0.0505 Europium-152 U 0.0242 +/-0.052 Europium-154 U -0.0362 +/-0.0528 Europium-155 U 0.00 +/-0.0536 Lead-212 0.573 +/-0.0504 Lead-214 0.509 +/-0.0895 Manganese-54 U -0.00731 +/-0.0194 Niobium-94 U 0.0186 +/-0.0153 Potassium-40 10.1 +/-0.742 Radium-226 0.372 +/-0.0778 Silver-108m U-0.000807

+/-0.0182 Thallium-208 0.168 +/-0.0358 0.0667 0.0732 0.129 0.0326 0.0215 0.0172 0.0151 0.0472 0.0406 0.0523 0.0271 0.0306 0.0165 0.0143 0.126 0.0326 0.0158 0.0163+/-0.146+/-0.113+/-0.360+/-0.0778+/-0.0251+/-0.0585+1-0.0505+/-0.052+/-0.0528+/-0.0536+/-0.0504+/-0.0895+/-0.0194+/-0.0153+/-0.742+/-0.0778+/-0.0182+/-0.0358 0.141 0.150 0.274 0.0686 0.0454 0.0365 0.0332 0.0982 0.0895 0.108 0.0561 0.0639 0.0351 0.0304 0.282 0.0686 0.0331 0.0345 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 08/29/06 1428 562373 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 08/25/06 1728 562337 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 80 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: Sample ID: 9106-0001-103F 170132021 Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.Ul Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.81 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-106F 170132022 SE 02-AUG-06 25-AUG-06 Client 16.2%Project: Client ID: Vol. Recv.: YANKO 1204 YANKOO I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.892 +/-0.192 Americium-241 U 0.0412 +/-0.0772 Bismuth-212 0.610 +/-0.303 Bismuth-214 0.718 +/-0.108 Cesium-134 U 0.0471 +/-0.046 Cesium-137 0.163 +/-0.0448 Cobalt-60 0.148 +/-0.0466 Europium-152 U -0.0545 +/-0.0732 Europium-154 U 0.0228 +/-0.0661 Europium-155 U 0.039 +/-0.0725 Lead-212 0.713 +/-0.0811 Lead-214 0.734 +/-0.110 Manganese-54 U -0.0271 +/-0.0227 Niobium-94 U -0.00686 +/-0.0193 Potassium-40 12.2 +/-1.09 Radium-226 0.718 +/-0.108 Silver-108m U 0.000841 +/-0.0201 Thallium-208 0.240 +/-0.051 0.0622 0.061 0.139 0.0348 0.0237 0.0186 0.021 0.0448 0.0574 0.0505 0.0286 0.0353 0.0177 0.0165 0.130 0.0348 0.0169 0.0172+/-0.192+/-0.0772+/-0.303+/-0.108+/-0.046+/-0.0448+/-0.0466+/-0.0732+/-0.0661+/-0.0725+/-0.0811+/-0.110+/-0.0227+/-0.0193+/-1.09+/-0.108+/-0.0201+/-0.051 0.124 0.122 0.278 0.0695 0.0474 0.0371 0.042 0.0894 0.115 0.101 0.0571 0.0705 0.0355 0.033 0.259 0.0695 0.0337 0.0344 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 08/28/06 1701 562372 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 08/25/06 1728 562337 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 82 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-106F Project: YANK01204 Sample ID: 170132022 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.83 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-106FS 170132023 SE 02-AUG-06 25-AUG-06 Client 16.6%Proiect: YANK01204 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnia,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.676 +/-0.168 Americium-241 U -0.0251 +/-0.108 Bismuth-212 0.464 +/-0.301 Bismuth-214 0.504 +/-0.0851 Cesium-134 U 0.032 +/-0.016 Cesium-137 0.234 +/-0.0437 Cobalt-60 0.230 +/-0.0517 Europium-152 U -0.0134 +/-0.0527 Europium-154 U -0.0267 +/-0.0592 Europium-155 U -0.00242 +/-0.0531 Lead-212 0.684 +/-0.0599 Lead-214 0.553 +/-0.0816 Manganese-54 U -0.00702 +/-0.0224 Niobium-94 U 0.0177 +/-0.0251 Potassium-40 10.2 +/-0.810 Radium-226 0.504 +/-0.0851 Silver- 108m U -0.00683 +/-0.0178 Thallium-208 0.228 +/-0.040 0.0598 0.087 0.124 0.032 0.0218 0.0164 0.0198 0.0444 0.0475 0.0502 0.0247 0.0323 0.0184 0.0163 0.144 0.032 0.0157 0.0178+/-0.168+/-0.108+/-0.301+/-0.0851+/-0.016+/-0.0437+/-0.0517+/-0.0527+/-0.0592+/-0.0531+/-0.0599+/-0.0816+/-0.0224+/-0.0251+/-0.810+/-0.0851+/-0.0178+/-0.040 0.129 0.180 0.268 0.0682 0.0465 0.0353 0.0435 0.0935 0.106 0.104 0.0516 0.068 0.0393 0.0347 0.327 0.0682 0.0331 0.0379 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 08/28/06 1757 562372 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 08/25/06 1728 562337 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 84 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gelcom Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-106FS Project: YANKO 1204 Sample ID: 170132023 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.85 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-1IOF 170132024 SE 02-AUG-06 25-AUG-06 Client 11.8%Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.640 Americium-241 U -0.0447 Bismuth-212 0.384 Bismuth-214 0.513+/-+/-+/--0.148-0.117-0.269-0.084 Cesium- 134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 U 0.0326 0.0609 UI 0.00 U 0.0514 U -0.0268 U 0.0111 0.584 0.598 U 0.019 U 0.00338 8.86 0.513 U -0.011 0.201+/-0.0274+/-0.0269+/-0.0366+/-0.0503+/-0.0584+/-0.0518+/-0.0556+/-0.0802+/-0.0322+/-0.0169+/-0.820+/-0.084+/-0.016+/-0.0386 0.0589 0.0916 0.139 0.0293 0.0208 0.0167 0.0272 0.0458 0.0465 0.0488 0.0254 0.0285 0.0168 0.0147 0.091 0.0293 0.0136 0.0146+/-0.148+/-0.117+/-0.269+/-0.084+/-0.0274+/-0.0269+/-0.0366+/-0.0503+/-0.0584+/-0.0518+/-0.0556+/-0.0802+/-0.0322+/-0.0169+/-0.820+/-0.084+/-0.016+/-0.0386 0.128 0.191 0.298 0.0626 0.0444 0.0358 0.0582 0.0962 0.104 0.101 0.0529 0.0603 0.0362 0.0315 0.221 0.0626 0.0289 0.0315 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 08/28/06 1757 562372 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 08/25/06 1728 562337 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 86 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-1 tOF Proiect: YANK01204 Sample ID: 170132024 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.87 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Ci-rtifienti-nf Annlvqiq Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Project: YANK01204 Client ID: YANKOO Vol. Recv.: Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-109F 170132025 SE 02-AUG-06 25-AUG-06 Client 14.6%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnmna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.01 +/-0.174 Americium-241 U -0.0336 +/-0.107 Bismuth-212 U 0.306 +/-0.287 Bismuth-214 0.657 +/-0.0986 Cesium-134 U 0.0496 +/-0.0372 Cesium-137 U-0.000678

+/-0.0234 Cobalt-60 U -0.00442 +/-0.0213 Europium-152 U -0.05 +/-0.0625 Europium-154 U 0.00746 +/-0.0686 Europium-155 U 0.0219 +/-0.0696 Lead-212 0.946 +/-0.0691 Lead-214 0.805 +/-0.0924 Manganese-54 U 0.0114 +/-0.0221 Niobium-94 U 0.00952 +/-0.0215 Potassium-40 8.69 +/-0.941 Radium-226 0.657 +/-0.0986 Silver-108m U 0.00241 +/-0.0198 Thallium-208 0.289 +/-0.0551 0.0584 0.0851 0.163 0.0393 0.0257 0.0204 0.0178 0.0512 0.0599 0.0515 0.0321 0.0424 0.0198 0.0193 0.180 0.0393 0.0169 0.0179+/-0.174+/-0.107+/-0.287+/-0.0986+/-0.0372+/-0.0234+/-0.0213+/-0.0625+/-0.0686+/-0.0696+/-0.0691+/-0.0924+/-0.0221+/-0.0215+/-0.941+/-0.0986+/-0.0198+1-0.0551 0.128 0.176 0.348 0.0833 0.0545 0.0435 0.0399 0.108 0.132 0.107 0.0667 0.0886 0.0426 0.041 0.404 0.0833 0.0358 0.0382 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 08/28/06 1758 562372 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 08/25/06 1728 562337 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 88 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-109F Project: YANK01204 Sample ID: 170132025 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.89 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-11 IF 170132026 SE 02-AUG-06 25-AUG-06 Client 14.7%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.799 +/-0.183 Americium-241 U 0.0218 +/-0.0914 Bismuth-212 0.561 +/-0.319 Bismuth-214 0.670 +/-0.0906 Cesium-134 U 0.0281 +/-0.0255 Cesium-137 0.161 +/-0.0372 Cobalt-60 0.114 +/-0.0405 Europium-152 U -0.0276 +/-0.0569 Europium-154 U 0.00614 +/-0.0742 Europium-155 U 0.0488 +/-0.0625 Lead-212 0.790 +/-0.0634 Lead-214 0.762 +/-0.0956 Manganese-54 U 0.000471 +/-0.0278 Niobium-94 U 0.0111 +/-0.0188 Potassium-40 9.54 +/-0.814 Radium-226 0.670 +/-0.0906 Silver-108m U 0.00951 +/-0.0179 Thallium-208 0.264 +/-0.0403 0.061 0.0787 0.116 0.0372 0.0219 0.0169 0.0157 0.049 0.0638 0.049 0.0269 0.034 0.0206 0.0171 0.156 0.0372 0.0161 0.0184+/-0.183+/-0.0914+/-0.319+/-0.0906+/-0.0255+/-0.0372+/-0.0405+/-0.0569+/-0.0742+/-0.0625+/-0.0634+/-0.0956+/-0.0278+/-0.0188+/-0.814+/-0.0906+/-0.0179+/-0.0403 0.132 0.162 0.251 0.0785 0.0466 0.0361 0.0352 0.103 0.138 0.101 0.0559 0.0712 0.0437 0.0363 0.350 0.0785 0.0339 0.0391 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 08/28/06 1758 562372 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 08/25/06 1728 562337 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 90 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-11 IF Project: YANKO 1204 Sample ID: 170132026 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.91 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-122F 170132027 SE 04-AUG-06 25-AUG-06 Client 21.2%Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gammna,Solid-FSS CAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.01 +/-0.178 Americium-241 U 0.00742 +/-0.106 Bismuth-212 0.593 +/-0.342 Bismuth-214 0.744 +/-0.102 Cesium-134 U 0.0465 +/-0.0409 Cesium-137 0.459 +/-0.0528 Cobalt-60 0.422 +/-0.0575 Europium-152 U 0.0297 +/-0.0563 Europium-154 U -0.0577 +/-0.0671 Europium-155 U 0.0335 +/-0.066 Lead-212 0.969 +/-0.0669 Lead-214 0.973 +/-0.0888 Manganese-54 U1 0.00 +/-0.0361 Niobium-94 U -0.00348 +/-0.0223 Potassium-40 10.5 +/-0.894 Radium-226 0.744 +/-0.102 Silver-108m U 0.0072 +/-0.0214 Thallium-208 0.297 +1-0.0501 0.0692 0.0874 0.161 0.039 0.0219 0.0219 0.0176 0.0516 0.0504 0.060 0.0332 0.0331 0.019 0.0186 0.148 0.039 0.0191 0.0223+/-0.178+/-0.106+/-0.342+/-0.102+/-0.0409+/-0.0528+/-0.0575+/-0.0563+/-0.0671+/-0.066+/-0.0669+/-0.0888+/-0.0361+/-0.0223+/-0.894+/-0.102+/-0.0214+1-0.0501 0.150 0.181 0.344 0.0828 0.047 0.0466 0.0396 0.109 0.113 0.124 0.0689 0.070 0.0411 0.0396 0.341 0.0828 0.0403 0.0472 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 08/28/06 1758 562372 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 08/25/06 1728 562337 The following Analytical Methods were performed Method Description 1 EML HIASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 92 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-122F Proiect: YANK01204 Sample ID: 170132027 Client ID: YANK00.1 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.93 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Project: YANKO 1204 Client ID: YANKOOI Vol. Recv.: Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-123F 170132028 SE 04-AUG-06 25-AUG-06 Client 24.4%Parameter Qualifier Result Uncertainty LC TPU. MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Ganimna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.999 +/-0.216 Americium-241 U -0.0566 +/-0.142 Bismuth-212 Ul 0.00 +/-0.367 Bismuth-214 0.697 +/-0.097 Cesium-134 Ul 0.00 +/-0.0669 Cesium-137 0.677 +/-0.0743 Cobalt-60 0.765 +/-0.0797 Europium-152 U -0.0283 +/-0.0665 Europium-154 U 0.0474 +/-0.0919 Europium-155 U 0.0227 +/-0.0704 Lead-212 0.945 +/-0.0833 Lead-214 0.898 +/-0.108 Manganese-54 U -0.0138 +/-0.0278 Niobium-94 U -0.00151 +/-0.0236 Potassium-40 13.1 +/-0.943 -Radium-226 0.697 +/-0.097 Silver-108m U 0.0262 +/-0.0237 Thallium-208 0.376 +/-0.0729 0.0826 0.0882 0.172 0.0381 0.0311 0.0227 0.0233 0.0568 0.0802 0.0621 0.0326 0.0434 0.0231 0.0194 0.166 0.0381 0.0216 0.0202+/-0.216+/-0.142+/-0.367+/-0.097+/-0.0669+/-0.0743+/-0.0797+/-0.0665+/-0.0919+/-0.0704+/-0.0833+/-0.108+/-0.0278+/-0.0236+/-0.943+/-0.097+/-0.0237+/-0.0729 0.176 0.182 0.366 0.081 0.0655 0.0482 0.051 0.119 0.172 0.128 0.0677 0.0906 0.0493 0.0414 0.376 0.081 0.0453 0.043 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 08/28/06 1759 562372 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 08/25/06 1728 562337 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 94 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-123F Project: YANK01204 Sample ID: 170132028 Client ID: YANKOO 1 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.95 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-124F 170132029 SE 04-AUG-06 25-AUG-06 Client 15.4%Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnnia,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.603 +/-0.135 Americium-241 U 0.0229 +/-0.132 Bismuth-212 0.568 +/-0.276 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.337 UI 0.00 0.285 0.254 U 0.0171 U 0.00232 U 0.0775 0.519 0.495 U 0.00887 U -0.00207 10.2 0.337 U -0.00278 0.191+/-1-+1-+1-+1-+1-+1--0.0681-0.0175-0.0412-0.0465-0.0391-0.0457-0.0639-0.0608-0.0854-0.0167 0.0498 0.087 0.104 0.025 0.0174 0.0126 0.0155 0.0357 0.0388 0.0413 0.0214 0.024 0.0152 0.0121 0.143 0.025 0.012 0.0129+/-0.135+/-0.132+/-0.276+/-0.0681+/-0.0175+/-0.0412+/-0.0465+/-0.0391+/-0.0457+/-0.0639+/-0.0608+/-0.0854+/-0.0167+/-0.0137+/-0.920+/-0.0681+/-0.0138+/-0.0398 0.106 0.179 0.221 0.0527 0.0366 0.0266 0.0335 0.0743 0.0842 0.085 0.0442 0.0502 0.0321 0.0256 0.311 0.0527 0.025 0.0273 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 08/28/06 1759 562372 1+/-0.0137+/-0.920+/-0.0681+/-0.0138+/-0.0398 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 08/25/06 1728 562337 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 96 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-124F Project: YANK01204 Sample ID: 170132029 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.97 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-125F 170132030 SE 04-AUG-06 25-AUG-06 Client 14.3%Proiect: YANKO1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gammna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.865 Arnericium-241 U -0.00558 Bismuth-212 0.440 Bismuth-214 0.680 Cesium-134 U 0.0459 Cesium-137 U 0.0271 Cobalt-60 UI 0.00 Europium-152 U -0.098 Europium-154 U -0.00194 Europium-155 U 0.0163 Lead-212 0.868 Lead-214 0.745 Manganese-54 U 0.0147 -Niobium-94 U -4.970E-+/-0.174+/-0.141+/-0.357+/-0.0966+/-0.0287+/-0.0264+/-0.056+/-0.0665+/-0.0598+/-0.0619+/-0.0614+/-0.085+/-0.0216+/-0.0185+/-0.827+/-0.0966+/-0.0187+/-0.0439 0.058 0.0859 0.115 0.0341 0.023 0.0168 0.0181 0.0445 0.0497 0.058 0.0281 0.0376 0.0175 0.0161 0.148 0.0341 0.0159 0.0186+/-0.174+/-0.141+/-0.357+/-0.0966+/-0.0287+/-0.0264+/-0.056+/-0.0665+/-0.0598+/-0.0619+/-0.0614+/-0.085+/-0.0216+/-0.0185+/-0.827+/-0.0966+/-0.0187+/-0.0439 0.125 0.176 0.248 0.0719 0.0485 0.0359 0.0396 0.0933 0.109 0.119 0.0582 0.0783 0.0374 0.0343 0.330 0.0719 0.0334 0.0392 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH.1 08/28/06 1759 562372 1 Potassium-40 Radium-226 Silver-108m Thallium-208 05 9.34 0.680 U -0.00151 0.279 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 08/25/06 1728 562337 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 98 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: Sample ID: 9106-0001-125F 170132030 Proiect: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.99 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-126F 170132031 SE 04-AUG-06 25-AUG-06 Client 15.3%Project: Client ID: Vol. Recv.: YANKO 1204 YANKOO I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.904 +/-0.256 Americium-241 U -0.0153 +/-0.0414 Bismuth-212 0.827 +/-0.447 Bismuth-214 0.766 +/-0.125 Cesium- 134 U 0.0359 +/-0.0647 Cesium-137 0.244 +/-0.0636 Cobalt-60 0.107 +/-0.0605 Europium-152 U 0.0382 +/-0.0714 Europium-154 U 0.000532 +/-0.0894 Europium-155 U 0.0784 +/-0.0637 Lead-212.

0.734 +/-0.0846 Lead-214 0.840 +/-0.117 Manganese-54 U 0.033 +/-0.0308 Niobium-94 U -0.00241 +/-0.0294 Potassium-40 10.3 +/-0.956 Radium-226 0.766 +/-0.125 Silver-108m U 0.00154 +/-0.0244 Thallium-208 0.268 +/-0.0712 0.0859 0.0328 0.171 0.0446 0.032 0.025 0.0254 0.062 0.075 0.0563 0.0411 0.0446 0.0277 0.0247 0.256 0.0446 0.0217 0.0248+/-0.256+/-0.0414+/-0.447+/-0.125+/-0.0647+/-0.0636+/-0.0605+/-0.0714+/-0.0894+/-0.0637+/-0.0846+/-0.117+/-0.0308+/-0.0294+/-0.956+/-0.125+/-0.0244+/-0.0712 0.184 0.0675 0.366 0.0942 0.0675 0.053 0.0554 0.129 0.162 0.116 0.0847 0.0931 0.0585 0.0521 0.556 0.0942 0.0455 0.0523 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 08/28/06 1800 562372 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 08/25/06 1728 562337 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 100 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 7, 2006 Client Sample ID: Sample ID: 9106-0001-126F 170132031 Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.101 I QUALITY CONTROL DATA 102 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Client: Connecticut Yankee Atomic Power 362 Injun Hollow Rd Renort Date: September 7, 2006 Page 1 of 12 East Hampton, Connecticut Contact: Mr. Jack McCarthy Workorder:

170132 Parmname Rad Alpha Spec Batch 562551 NOM Samnle Oual QC Units RPD%REC% Range Anist Date Time QCI201169378 Americium-241 170125005 DUP Curium-242 Curium-243/244 QC1201169380 LCS Americium-241 Curium-242 Curium-243/244 QC1201169377 MB Americium-241 Curium-242 Curium-243/244 QC1201169379 170125005 MS Americium-241 Curium-242 Curium-243/244 U 0.0864 Uncert: +/-0.0853 TPU: +/-0.086 U 0.0159 Uncert: +/-0.0423 TPU: +/-0.0423 U 0.0681 Uncert: +/-0.077 TPU: +/-0.0774 7.03 Uncert: TPU: Uncert: TPU: 8.50 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 10.8 U 0.0864 Uncert: +/-0.0853 TPU: +/-0.086 U 0.0159 Uncert: +/-0.0423 TPU: +/-0.0423 13.0 U 0.0681 Uncert: +/-0.077 TPU: +/-0.0774 U 0.067+/-0.138+/-0.138 U -0.0253+/-0.0286+/-0.0288 U 0.0674+/-0.134+/-0.134 6.32+/-0.638+1-1.05 U -0.0483+/-0.0462+/-0.0466 7.03+/-0.676+/-1.15 U 0.117+/-0.126+/-0.126 U -0.0282+/-0.0226+/-0.0229 U 0.00383+/-0.0932+/-0.0932 10.7+/-1.09+/-1.83 U -0.00492+/-0.0956+/-0.0956 12.6+/-1.18+/-2.09 pCi/g 25 pCi/g 877 pCi/g 1.(0% -100%) DDRI 09/03/06 12:11 (0%- 100%)(0%- 100%)pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 90 (75%-125%)

09/03/06 12:11 83 (75%-125%)

09/03/06 12:11 99 (75%-125%)

09/03/06 12:11 97 (75%-125%)

Batch 562552 QC1201169382 170125005 DUP Plutonium-238 U 0.00945 U -0.0244 pCi/g 453 (0% -100%) DDRI 09/03/06 12:11 103 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

170132 Page 2 of 12 Parmname NOM Sample Oual OC Units RPD%REC% Range AnIst Date Time Rad Alpha Spec Batch 562552 Plutonium-239/240 QC1201169384 LCS Plutonium-238 Plutonium-239/240 QC1201169381 MB Plutonium-238 Uncert: +/-0.102 TPU: +/-0.102 U -0.0435 Uncert: +/-0.0791 TPU: +/-0.0793 Uncert: TPU: 6.50 Uncert: TPU:+/-0.0891+/-0.0891 U -0.0188+/-0.0643+/-0.0643 U 0.046+/-0.089+/-0.0891 6.14+/-0.642+/-0.894 U -0.00886+/-0.0458+/-0.0458 U -0.00403+/-0.0448+/-0.0448 pCi/g 79 (0%- 100%)(75%-125%)

Plutoniurn-239/240 QC1201169383 170125005 MS Plutonium-238 Plutonium-239/240 Uncert: TPU: Uncert: TPU: pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 09/03/06 12:11 09/03/06 12:11 95 (75%-125%)

U 0.00945 Uncert: +/-0.102 TPU: +/-0.102 9.95 U -0.0435 Uncert: +/-0.0791 TPU: +/-0.0793 U -11.3 Uncert: +/-11.8 TPU: +/-11.8 U-0.0645+/-0.0868+/-0.0871 8.77+/-0.927+/-1.28 (75%-125%)

88 (75%-125%)

Batch 562553 QC1201169386 170125005 DUP Plutonium-241 QC1201169388 LCS Plutonium-241 U-7.26+/-11.7+/-11.7 160+1-15.5+/-22.2 QC1201169385 MB Plutonium-241 188 Uncert: TPU: Uncert: TPU: pCi/g pCi/g pCi/g pCi/g 0 85 (75%-125%)

(0% -100%) DDR I 09/06/06 16:50 09/06/06 17:22 09/06/06 16:34 09/06/06 17:06 U -8.25+/-9.47+/-9.47 QC1201169387 170125005 MS Plutonium-241 Rad Gamma Spec Batch 562372 QC1201168948 170125001 DUP Actinium-228 201 U Uncert: TPU:-11.3+/-11.8+/-11.8 203+/-19.1+/-28.7 101 (75%-125%)

0.305 Uncert: +/-0.0937 U1 0.00+/-0.0926+/-0.0926 pCi/g 6 (0% -100%) MJHI 08/29/06 14:27 104 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

170132 Page 3 of 12 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 562372 Americium-241 Bismuth-212 Bismuth-214 Cesium- 134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 TPU: +/-0.0937 U -0.00488 Uncert: +/-0.0494 TPU: +/-0.0494 0.199 Uncert: +/-0.157 TPU: +/-0.157 0.213 Uncert: +/-0.053 TPU: +/-0.053 U -0.000615 Uncert: +/-0.0135 TPU: +/-0.0135 0.235 Uncert: +/-0.0299 TPU: +/-0.0299 0.0679 Uncert: +/-0.0301 TPU: +/-0.0301 U 0.015 Uncert: +/-0.033 TPU: +/-0.033 U 0.0132 Uncert: +/-0.0356 TPU: +/-0.0356 U -0.0237 Uncert: +/-0.0376 TPU: +/-0.0376 0.269 Uncert: +/-0.0389 TPU: +/-0.0389 0.268 Uncert: +/-0.0568 TPU: +/-0.0568 U 0.00705 Uncert: +/-0.0128 TPU: +/-0.0128 U -0.00239 Uncert: +/-0.0114 TPU: +/-0.0114 5.10 Uncert: +/-0.471 TPU: +/-0.471 0.213 Uncert: +/-0.053 TPU: +/-0.053 U -0.00762 Uncert: +/-0.012 U -0.0681+/-0.139+/-0.139 U 0.242+/-0.144+/-0.144 0.230+/-0.0744+/-0.0744 U 0.017+/-0.0186+/-0.0186 0.204+/-0.0397+/-0.0397 0.0892+/-0.0361+/-0.0361 U -0.0104+/-0.0473+/-0.0473 U -0.0214+/-0.0491+/-0.0491 U -0.00448+/-0.0462+/-0.0462 0.244+/-0.0483+/-0.0483 0.223+/-0.0607+/-0.0607 U 0.00379+/-0.0164+/-0.0164 U 0.000295+/-0.016+/-0.016 4.91+/-0.656+/-0.656 0.230+/-0.0744+/-0.0744 U -0.00096+/-0.0146 pCi/g 173 pCi/g 20 pCi/g 8 pCi/g 215 pCi/g 14 pCi/g 27 pCi/g 1120 pCi/g 844 pCi/g 136 pCi/g 10 pCi/g 18 pCi/g 60 pCi/g 256 pCi/g 4 pCi/g 8 pCi/g 155 (0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%-20%)(0%- 100%)(0%- 100%)Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Workorder:

170132 Parmname Rad Gamma Spec Batch 562372 Thallium-208 QC1201168949 LCS Actinium-228 Americium-24 I Bismuth-212 Bismuth-214 Cesium-134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 QC Summary Sample Qual QC NOM Units RPD%Page 4 of 12 REC% Range Anlst Date Time (0%- 100%)TPU: Uncert: TPU: Uncert: TPU: 23.4 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 9.58 Uncert: TPU: 14.5 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-0.012 0.0606+/-0.0255+/-0.0255+/-0.0146 0.106+/-0.0385+/-0.0385 U -0.109+/-0.648+/-0.648 24.5+/-0.624+/-0.624 U 1.13+1-1.10+/-1.10 u 0.00418+/-0.263+/-0.263 u 0.0393+/-0.159+/-0.159 10.4+/-0.509+/-0.509 15.4+/-0.682+/-0.682 0.495+/-0.394+/-0.394 U -0.144+/-0.295+/-0.295 U 0.295+/-0.369+/-0.369 U -0.0816+/-0.166+/-0.166 U 0.121+/-0.199+/-0.199 U 0.0342+/-0.146+/-0.146 U -0.14+/-0.131+/-0.131 U 0.363 pCi/g 54 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 08/28/06 18:06 105 (75%-125%)

108 (75%-125%)

106 (75%-125%)

106 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

170132 Page 5 of 12 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Gamma Spec Batch 562372 Radium-226 Silver-108m Thallium-208 QC1201168947 Actinium-228 Americium-241 MB Bismuth-212 Bismuth-214 Cesium- 134 Cesium-137 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-1.23+/-1.23 U 0.00418+/-0.263+/-0.263 U -0.0232+/-0.118+/-0.118 U -0.106+/-0.128+/-0.128 U 0.0253+/-0.0412+/-0.0412 U -0.000294+/-0.0103+/-0.0103 U -0.0573+/-0.105+/-0.105 U 0.0142+/-0.0246+/-0.0246 U -0.006+/-0.013+/-0.013 U 0.00358+1-0.0115+/-0.0115 U 0.00466+/-0.0132+/-0.0132 U -0.0168+/-0.0401+/-0.0401 U -0.0107+/-0.0371+/-0.0371 U 0.00224+/-0.0185+/-0.0185 U 0.0215+/-0.0162+/-0.0162 U 0.0147+/-0.0208+/-0.0208 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pci/g pCi/g PCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 08/28/06 18:00 (75%-125%)

Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-2l4 107 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Workorder:

170132 Parmname QC Summary Page 6 of 12 NOM Sample Qual QC UJnits RPD 0/REC% Ranee Anlst Date Time Units RPD% REC% Range Artist Rad Gamma Spec Batch 562372 Manganese-54 Niobium-94 Potassium-40 Radium-226 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Silver-108m Thallium-208 Batch 562373 QC1201168951 Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 170132001 DUP 0.940 Uncert: +/-0.143 TPU: +/-0.143 U -0.0463 Uncert: +/-0.0742 TPU: +/-0.0742 0.504 Uncert: +/-0.254 TPU: +/-0.254 0.724 Unceri: +/-0.0757 TPU: +/-0.0757 U 0.0291 Uncert: +/-0.032 TPU: +/-0.032 0.743 Uncert: +/-0.0489 TPU: +/-0.0489 0.627 Uncert: +/-0.0612 TPU: +/-0.0612 U -0.00488 Uncert: +/-0.0485 TPU: +/-0.0485 U 0.029 Uncert: +/-0.0513 TPU: +/-0.0513 U 0.0447 U 0.00907+/-0.0108+/-0.0108 U -0.00448+/-0.00974

+/-0.00974 U 0.303+/-0.175+/-0.175 U 0.0142+/-0.0246+/-0.0246 U 0.000295+/-0.00968

+/-0.00968 U 0.0058+/-0.0123+/-0.0123 0.916+/-0.129+/-0.129 U 0.0649+/-0.0752+/-0.0752 0.580+/-0.264+/-0.264 0.726+/-0.0789+/-0.0789 UI 0.00+/-0.0338+/-0.0338 0.729+/-0.0496+/-0.0496 0.538+/-0.064+/-0.064 U -0.0138+/-0.0487+/-0.0487 U -0.00552+/-0.0452+/-0.0452 U 0.00 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 3 pCi/g 1190 pCi/g 14 pCi/g 0 pCi/g 60 pCi/g 2 pCi/g 15 pCi/g 95 pCi/g 294 pCi/g 25 (0%- 100%) MJHI 08/29/06 14:29 (0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0% -100%)(0%- 100%)108 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

170132 Page 7 of 12 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 562373 Lead-212 Lead-214 Manganese-54 Niobiumn-94 Potassium-40 Radium-226 Silver- 108m Thallium-208 QC12O1168952 Actinium-228 Americium-241 Uncert: +/-0.0581 TPU: +/-0.0581 0.941 Uncert: +/-0.0572 TPU: +/-0.0572 0.858 Uncert: +/-0.0803 TPU: +/-0.0803 u 0.0142 Uncert: +/-0.0214 TPU: +/-0.0214 U 0.00021 Uncert: +/-0.0166 TPU: +/-0.0166 10.8 Uncert: +/-0.700 TPU: +/-0.700 0.724 Uncert: +/-0.0757 TPU: +/-0.0757 U -0.00568 Uncert: +/-0.0162 TPU: +/-0.0162 0.261 Uncert: +/-0.0377 TPU: +/-0.0377+/-0.0537+/-0.0537 0.883+/-0.0569+/-0.0569 0.818+/-0.0652+/-0.0652 U -0.00626+/-0.0183+/-0.0183 U 0.0224+/-0.0212+/-0.0212 11.3+/-0.675+/-0.675 0.726+/-0.0789+/-0.0789 U 0.00672+/-0.0152+/-0.0152 0.329+/-0.0399+/-0.0399 U 0.00153+/-0.701+/-0.701 23.9+/-1.18+/-1.18 U -0.0231+/-1.03+/- 1.03 U 0.190+/-0.239+/-0.239 U -0.00599+/-0.144+/-0.144 10.1+/-0.514+/-0.514 14.9+/-0.720+/-0.720 pCi/g 6 pCi/g 5 pCi/g 517 pCi/g 196 pCi/g 5 pCi/g 0 pCi/g 2380 pCi/g 23 (0%-20%)(0% -20%)(0%- 100%)(0%- 100%)(0%- 20%)(0%- 100%)(0%- 100%)(0%- 100%)LCS Bismuth-212 Bismuth-214 Cesium-134 Cesium- 137 Uncert: TPU: 23.4 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 9.58 Uncert: TPU: 14.5 Uncert: TPU: pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 102 (75%-125%)

08/29/06 14:29 106 (75%-125%)

103 (75%-125%)

Cobalt-60 109 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

170132 Page 8 of 12 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 562373 Europium-152 U -0.18 pCi/g Uncert: +/-0.328 TPU: +/-0.328 Europium-154 U 0.227 pCi/g Uncert: +/-0.271 TPU: +/-0.271 Europium-155 U -0.143 pCi/g Uncert: +/-0.295 TPU: +/-0.295 Lead-212 U -0.0695 pCi/g Uncert: +/-0.169 TPU: +/-0.169 Lead-214 U 0.0167 pCi/g Uncert: +/-0.233 TPU: +/-0.233 Manganese-54 U -0.104 pCi/g Uncert: +/-0.143 TPU: +/-0.143 Niobium-94 U -0.0889 pCi/g Uncert: +/-0.120 TPU: +/-0.120 Potassium-40 U 0.272 pCi/g Uncert: +/-1.10 TPU: +/-1.10 Radium-226 U 0.190 pCi/g (75%-125%)

Uncert: +/-0.239 TPU: +/-0.239 Silver-I 08m U -0.0248 pCi/g Uncert: +/-0.120 TPU: +/-0.120 Thallium-208 U -0.134 pCi/g Uncert: +/-0.124 TPU: +/-0.124 QC1201168950 MB Actinium-228 U 0.0216 pCi/g 08/29/06 14:28 Uncert: +/-0.0695 TPU: +/-0.0695 Americium-241 U 0.0136 pCi/g Uncert: +/-0.0649 TPU: +/-0.0649 Bismuth-212 U -0.0269 pCi/g Uncert: +/-0.0962 TPU: +/-0.0962 Bismuth-214 U 0.0038 pCi/g Uncert: +/-0.0237 TPU: +/-0.0237 Cesium-134 U 0.00475 pCi/g Uncert: +/-0.0121 110 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

170132 Page 9 of 12 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 562373 TPU: +/-0.0121 Cesium- 137 U 0.00641 pCi/g Uncert: +/-0.0202 TPU: +/-0.0202 Cobalt-60 U 0.00173 pCi/g Uncert: +/-0.0104 TPU: +/-0.0104 Europium-152 U -0.00536 pCi/g Uncert: +/-0.0301 TPU: +/-0.0301 Europium-154 U -0.00864 pCi/g Uncert: +/-0.0277 TPU: +/-0.0277 Europium-155 U -0.0398 pCi/g Uncert: +/-0.0316 TPU: +/-0.0316 Lead-212 U 0.0203 pCi/g Uncert: +/-0.0328 TPU: +/-0.0328 Lead-214 U 0.0056 pCi/g Uncert: +/-0.0235 TPU: +/-0.0235 Manganese-54 U -0.00481 pCi/g Uncert: +/-0.0107 TPU: +/-0.0107 Niobium-94 U -0.00067 pCi/g Uncert: +/-0.0103 TPU: +/-0.0103 Potassium-40 U 0.0956 pCi/g Uncert: +/-0.244 TPU: +/-0.244 Radium-226 U 0.0038 pCi/g Uncert: +/-0.0237 TPU: +/-0.0237 Silver-108m U -0.00607 pCi/g Uncert: +/-0.00977 TPU: +/-0.00977 Thallium-208 U 0.0123 pCi/g Uncert: +/-0.011 TPU: +/-0.011 Rad Gas Flow Batch 562545 QC1201169352 170132001 DUP Strontium-90 U 0.00389 U -0.00664 pCi/g 0 (0%- 100%) KSDI 08/30/06 18:45 Uncert: +/-0.0104

+/-0.0116 TPU: +/-0.0104

+/-0.0116 QC1201169354 LCS Strontium-90 1.21 1.03 pCi/g 86 (75%-125%)

08/30/06 19:22 ill GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Workorder:

170132 Parmname Rad Gas Flow Batch 562545 QC1201169351 MB Strontium-90 QC1201169353 170132001 MS Strontium-90 Rad Liquid Scintillation Batch 562518 QC1201169279 170125003 DUP Tritium QC1201169281 LCS Tritium QC1201169278 MB Tritium QC1201169280 170125003 MS Tritium Batch 562520 QC1201169283 170125007 DUP Iron-55 QC1201169285 LCS Iron-55 QC1201169282 MB Iron-55 QC1201169284 170125007 MS Iron-55 Batch 562521 QC1201169287 170125007 DUP Nickel-63 NOM Uncert: TPU Uncert: TPU 1.20 Uncert: TPU Uncert: TPU 11.3 Uncert: TPU Uncert: TPU 10.7 Uncert: TPU Uncert: TPU: 631 Uncert: TPU: Uncert: TPU: 660 Uncert: TPU: U QC Summary Sample Qual QC+/-0.104+/-0.108 U 0.0149+/-0.0105+/-0.0105 0.00389 1.08+/-0,0104

+/-0l I+/-0.0104

+/-0.114 Page 10of 12 Units RPD% REC% Range Anist Date Time pci/g pCi/g 90 (75%-125%)

U 0.119+/-1.35+/-1.35 U 0.119+/-1.35+/-1.35 U 9.61+/-36.3+/-36.3 U 9.61+/-36.3+/-36.3 U 9.73 U 1.40+/-I .58+/- 1.58 10.8+/-3.03+/-3.04 U -0.193+/- 1.43+/-1.43 8.79+/-2.73+/-2.74 U 14.5+/-38.8+/-38.8 590+/-53.7+/-64.0 U 24.7+/-38.2+/-38.3 664+/-57.1+/-69.8 U 1.41 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 0 (0% -100%) DFA 1 96 (75%-125%)

08/30/06 18:46 08/30/06 18:46 08/31/06 13:04 08/30/06 11:17 08/31/06 12:42 08/30/06 11:01 09/01/06 19:36 09/01/06 20:09 09/01/06 19:20 09/01/06 19:52 82 (75%-125%)

0 (0% -100%) vlXPI 93 (75%-125%)

101 (75%-125%)

pCi/g 0 (0%- 100%) vAXPI 09/01/06 04:23 112 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

170132 Page 11 of 12 Parmname NOM Sample Qual QC Units RPD%REC% Range Anist Date Time Rad Liquid Scintillation Batch 562521 QC1201169289 LCS Nickel-63 QC1201169286 MB Nickel-63 QC1201169288 170125007 MS Nickel-63 Uncert: TPU: 512 Uncert: TPU: Uncert: TPU: 512 U Uncert: TPU:+/-8.38+/-8.38+/-8.97+/-8.97 442+/-15.2+/-20.7 U 3.69+/-7.93+/-7.93 pCi/g pCilg PCilg 86 (75%-125%)

09/01/06 05:26 09/01/06 03:51 09/01/06 04:55 9.73+/-8.38+/-8.38 455+/-17.9+/-23.0 89 (75%-125%)

Batch 562522 QC1201169291 170132002 DUP Carbon- 14 QC1201169293 Carbon-14 LCS 0.155 Uncert: +/-0.0912 TPU: +/-0.0912 6.87 Uncert: TPU: Uncert: TPU: QC1201169290 MB Carbon-14 QC1201169292 170132002 MS Carbon- 14 7.26 Uncert: TPU: 0.155+/-0.0912+/-0.0912 U 0.137+/-0.0943+/-0.0943 6.52+/-0.495+/-0.505 U -0.0361+/-0.0805+/-0.0805 7.06+/-0.513+/-0.524 U 0.038+/-0.213+/-0.213 11.6+/-0.350+/-0.439 U -0.00485+/-0.166+/-0.166 PCi/g PCi/g pCi/g 95 (75%-125%)

pCi/g 12 (0%- 100%) kXD2 08/30/06 04:42 08/30/06 05:47 08/30/06 03:54 08/30/06 05:29 95 (75%-125%)

Batch 562651 QC1201169592 170132002 DUP Technetium-99 QC1201169594 LCS Technetium-99 QC1201169591 MB Technetium-99 QC1201169593 170132002 MS Technetium-99 U 0.00437 Uncert: +/-0.175 TPU: +/-0.175 12.9 Uncert: TPU: Uncert: TPU: pCi/g pCi/g pCi/g pCi/g 0 (0% -100%) K.XRI 90 (75%-125%)

09/02/06 13:09 09/02/06 14:12 09/02/06 12:38 09/02/06 13:41 12.9 U Uncert: TPU: 0.00437+/-0.175+/-0.175 12.0+/-0.396+/-0.481 93 (75%-125%)

113 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

170132 Page 12 of 12 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike cone. by a factor of 4 or more.** Indicates analyte is a surrogate compound.A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.114 Table of Contents G eneral Narrative

.................................................................

.I Chain of Custody and Supporting Documentation

...........

4 Radiological Analysis ..........................................................

9 Sam ple Data Sum m ary ......................................................

14 Q uality C ontrol D ata ...........................................................

36 General Narrative 1 CASE NARRATIVE For CONNECTICUT YANKEE RE: Soil PO# 002332 Work Order: 169489 SDG: MSR #06-1130 August 21, 2006 Laboratory Identification:

General Engineering Laboratories, LLC Mailing Address: P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address: 2040 Savage Road Charleston, South Carolina 29407 Telephone Number: (843) 556-8171 Summary: Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL)in Charleston, South Carolina on August 17, 2006. All sample containers arrived without any visible signs of tampering or breakage.

The chain of custody contained the proper documentation and signatures.

The laboratory received the following sample(s):

Sample ID Client Sample ID 169489001 9106-0001-132F 169489002 9106-0001-112F 169489003 9106-0001-132A 169489004 9106-0001-132B 169489005 9106-0001-132C 169489006 9106-0001-132D 169489007 9106-0001-112A 169489008 9106-0001-112B 169489009 9106-0001-112C 169489010 9106-0001-112D GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.P.O. Box 30712 -Charleston, SC 29417

  • 2040 Savage Road (29407)Phone (843) 556-8171 ° F. (843) 766-1178 -www.gel.com Items of Note: There are no items of note.Case Narrative:

Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures.

Any technical or administrative problems during analysis, data review, and reduction are listed below by analytical parameter.

Analytical Request: Ten soil samples were analyzed for FSSGAM.Internal Chain of Custody: Custody was maintained for the sample(s).

Data Packaye: The enclosed data package contains the following sections:

Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.P.O. Box 30712 -Charleston, SC 29417 -2040 Savage Road (29407)Phone (843) 556-8171 -FS (843) 766-1178 -www.gel.com Chain of Custody And Supporting Documentation 4

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major O1 Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00496 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556

______-_______

____" _"__.,__________

__-___________._,_____'__.___

___ ,___ -_____Project Name: Haddam Neck Decommissioning Analyses Requested Use On,,, .Contact Name & Phone: Comlimenlts " Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories .. " 2040 Savage Road. Charleston SC. 29407 < ii- * , 843 556 8171. Attn. Cheryl Jones Priority:[]30D.

Ej 14D. El-7D.Z3 D.Container Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation .I-.S., ID Code Code Code 9106-0001-132F SE C BP X 9106-0001-112F SE C BP X 9106-0001-132A SE C BP X ' .9106-0001-132B SE C BP X 9106-0001-132C SE C BP X 9106-0001-132D SE C BP X 9106-0001-1 12A SE C BP x 9106-0001-112B SE C BP X 9106-0001-112C SE C BP X NOTES: PO #: 002332 MSR #: 06- m3o0 SSWP# NA Z LTP QA 0 Radwaste QA E] Non QA Samples Shipped Via: 'Internal Container Z Fed Ex _Tern Dg C] Hand X. ustody'Sciled9

1) Relinquished By Date ime 2) Received By D te/Time tu".0 "stody Seal .J'-IP 6RICAT C Jc2 0 j__ .QL e,. I/SI Other I_.ntac'&?
3) Relinquished By Date/Time
4) Received By Date/Time

_.._ ? NO Bill of Lading #5) Relinquished By Date/Time

6) Received By Date/Time
79 ,_/ 8)30 3 0 -.

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 oject Name: Haddam Neck Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones r~ ;?~ ~~r Priority:

[] 30 D. [] 14 D. ] 7 D. Z 3 D...... ... .. li" "" .. ........ ... .. .......... ..... ....,, , ,, -.....Sample Designation I Date Comment, Preservation I ID* Samples Shipped Via: Z Fed Ex El UPS El Hand Ml Other Bill of Lading #;q/ 91,70 3 4cZ Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-OO0 Figure 1. -Sample Check-in List Date/Time Received:

91171040 SDG#: U /#(-/3 Work Order Number:/49 t8 Shipping Cdntainer ID: 7921 6130 ,,?Z. Chain of Custody # -P0 Vi9. '1. Custody Seals ori shipping container intact? *Yes t I No [W,"" 2. Custody Seals dated and signed? Yes [ ] No [1 3. Chain-of-Custody record present? Yes kl"No I ]4. Cooler temperature 2 " 5. Vermiculite/packing materials is: Wet ( TD 6. Number of samples in shipping container:

/0 " 3cIp /s 7. Sample holding times exceeded?

Yes [ No [ ]10. Were any anomalies identified in sample receipt? Yes [ ] No ['-" I V. *Description of anomalies (include sample numbers):

--- --Sample CustodianlIaboratory:

.Date e. 7 Telephoned to: nBy-on._7 0 SAMPLE RECEIPT & REVIEW FORM CONTINUATION FORM-&crnnic-i ci4- Yrrn~nle.

IA-ni c. --lD CL-6 -3 r -T~~7 rnc!Oo --I'3z-., F , l I No -13 2-I- i D f5-LSOo O'o 1(,o- 11'2, 18 2--_0 No 13:54 91 L 1o- !12, O (p o o-I '. 4, 0(D 6 ok1"LO0ov -- Do q b 9 !Ou --007, Sq 9l -- -OOý3&A -[5- ,- , , loLt)-- o04SUR 8-i1-0 0 I:',13 9lJo0 --006,3U eq, -b k I:5'o 8 RADIOLOGICAL ANALYSIS 9 Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)Work Order 169489 Method/Analysis Information Product: Analytical Method: Prep Method: Analytical Batch Number: Prep Batch Number: Sample ID 169489001 169489002 169489003 169489004 169489005 169489006 169489007 169489008 169489009 169489010 1201161904 1201161905 1201161906 Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep 559393 559366 Client ID 9106-0001-132F 9106-0001-112F 9106-0001-132A 9106-0001-132B 9106-0001-132C 9106-0001-132D 9106-0001-112A 9106-0001-112B 9106-0001-112C 9106-0001-112D Method Blank (MB)169489001(9106-0001

-1 32F) Sample Duplicate (DUP)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 11.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).10 Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 169489001 (9106-0001-132F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

The following NCR was generated for this SDG: NCR 348221 was generated due to Failed RPD for DUP. 1. The relative percent difference (169489001 and 1201161905) did not meet the required duplication criteria for Lead-212 at 23.486%.1. Pb-212 is a naturally emitting isotope. Reporting results.Additional Comments Additional comments were not required for this sample set.Qualifier information 11 Qualifier Reason Analyte Sample UI UI Data rejected due to high peak-width.

Data rejected due to interference.

Bismuth-212 169489001 Cesium-134 169489003 Europium-155 Cesium- 134 UI Data rejected due to low abundance.

169489001 169489003 169489002 169489004 169489005 169489007 169489008 169489009 169489010 1201161905 Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator.

In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.The following data validator verified the information presented in this case narrative: , ý') 'El r- I la, Reviewer/Date:

12 General Engineering Laboratories Form GEL-NCR Rev. 06/05 NCR Report No.: 348221 Revision No.: COMPANY -WIDE NONCONFORMANCE REPORT Mo.Day Yr. Division:

Quality Criteria:

Type: 21-AUG-06 Radiochemistry Specifications Process Instrument Type: Test I Method: Matrix Type: Client Code: GAMMA SPECTROMETER EML HASL 300, 4.5.2.3 Solid YANK Batch ID: Sample Numbers: 559393 See Below Potentially affected work order(s)(SDG):

169489(MSR#06-1130),169493(MSR#06-1131)

Application Issues: Failed RPD for DUP Specification and Requirements NRG Disposition:

Nonconformance

==

Description:==

1. The relative percent difference (169489001 and 1201161905) did not 1. Pb-212 is a naturally emitting isotope. Reporting results.meet the required duplication criteria for Lead-212 at 23.486%.Originator's Name: Jimmy Hartley Quality Review: Data Validator/Group Leader: Heather Anderson 21 -AUG-06 21-AUG-06 Director: Page 1 13 SAMPLE DATA

SUMMARY

14 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.Client SDG: MSR#06-1130 GEL Work Order: 169489 The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria** Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures.

Please direct any questions to your Project Manager, Cheryl Jones.Reviewed by 15 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: 9106-0001-132F Project: YANKO 1204 Sample ID: 169489001 Client ID: YANK001 Matrix: SE Vol. Recv.: Collect Date: 07-AUG-06 Receive Date: 17-AUG-06 Collector:

Client Moisture:

27.9%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-1 55 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver- 108m Thallium-208 1.03 U 0.0548 UI 0.00 0.654 U 0.0706 0.558 1.66 U -0.0057 U -0.0388 UI 0.00 0.799 0.805 U-0.000465 U -0.00327 11.3 0.654 U 0.00854 0.394+/-0.245+/-0.103+/-0.427+/-0.137+/-0.0524+/-0.0668+/-0.124+/-0.0712+/-0.0741+/-0.111+/-0.0747+/-0.123+/-0.0303+/-0.0264+/- 1.02+/-0.137+/-0.0236+/-0.0629 0.0918 0.087 0.207 0.0399 0.0345 0.0252 0.0235 0.0589 0.0596 0.0544 0.0323 0.0402 0.0254 0.0223 0.185 0.0399 0.0212 0.0188+/-0.245+/-0.103+/-0.427+/-0.137+/-0.0524+/-0.0668+/-0.124+/-0.0712+/-0.0741+/-0.111+/-0.0747+/-0.123+/-0.0303+/-0.0264+/-1.02+/-0.137+/-0.0236+/-0.0629 0.196 0.180 0.436 0.0847 0.0725 0.0533 0.0517 0.123 0.132 0.113 0.067 0.0843 0.0539 0.0471 0.419 0.0847 0.0445 0.0403 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 08/18/06 1315 559393 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 08/17/06 1312 559366 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 16 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-132F Project: YANKO 1204 Sample ID: 169489001 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.17 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-112F 169489002 SE 02-AUG-06 17-AUG-06 Client 43.6%Proiect: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.06 +/-0.211 Americium-241 U 0.125 +/-0.116 Bismuth-212 0.851 +/-0.345 Bismuth-214 0.905 +/-0.111 Cesium-134 UI 0.00 +/-0.0393 Cesium-137 2.34 +/-0.111 Cobalt-60 2.65 +/-0.124 Europium-152 U -0.00432 +/-0.0724 Europium-154 U -0.0153 +/-0.0839 Europium-155 U 0.0707 +/-0.0686 Lead-212 1.25 +/-0.0793 Lead-214 0.949 +/-0.113 Manganese-54 U 0.0451 +/-0.0419 Niobium-94 U 0.012 +/-0.0252 Potassium-40 13.9 +/-0.991 Radium-226 0.905 +/-0.111 Silver-108m U 0.0214 +1-0.0315 Thallium-208 0.418 +/-0.0636 0.107 0.0817 0.188 0.0425 0.0314 0.0256 0.0239 0.0607 0.0694 0.0593 0.0339 0.045 0.0263 0.0217 0.207 0.0425 0.0236 0.0225+/-0.211+/-0.116+/-0.345+/-0.111+/-0.0393+/-0.111+/-0.124+/-0.0724+/-0.0839+/-0.0686+/-0.0793+/-0.113+/-0.0419+/-0.0252+/-0.991+/-0.111+/-0.0315+/-0.0636 0.221 0.167 0.390 0.0881 0.0651 0.0532 0.0508 0.125 0.147 0.121 0.0694 0.0927 0.0547 0.0451 0.444 0.0881 0.0485 0.0468 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 08/18/06 1315 559393 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 08/17/06 1312 559366 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 18 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-112F Project: YANKO1204 Sample ID: 169489002 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.Ul Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.19 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-132A 169489003 SE 11-AUG-06 17-AUG-06 Client 31.8%Proiect: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Ganmma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.19 +/-0.207 Americium-241 U 0.0893 +/-0.121 Bismuth-212 0.712 +/-0.213 Bismuth-214 0.833 +/-0.0801 Cesium-134 UI 0.00 +/-0.0324 Cesium-137 0.525 +/-0.0438 Cobalt-60 1.62 +/-0.0869 Europium-152 U -0.0472 +/-0.0519 Europium-154 U 0.0684 +/-0.0623 Europium-155 UI 0.00 +/-0.0727 Lead-212 1.08 +/-0.0562 Lead-214 0.970 +/-0.0862 Manganese-54 U-0.000782

+/-0.0227 Niobium-94 U 0.00632 +/-0.0182 Potassium-40 13.0 +/-0.754 Radium-226 0.833 +/-0.0801 Silver-108m U -0.00519 +/-0.017 Thallium-208 0.316 +/-0.0483 0.0693 0.0963 0.133 0.0311 0.0188 0.0172 0.0166 0.0414 0.0535 0.0442 0.0234 0.0306 0.0187 0.0156 0.126 0.0311 0.0147 0.016+/-0.207+/-0.121+/-0.213+/-0.0801+/-0.0324+/-0.0438+/-0.0869+/-0.0519+/-0.0623+/-0.0727+/-0.0562+/-0.0862+/-0.0227+/-0.0182+/-0.754+/-0.0801+/-0.017+/-0.0483 0.144 0.197 0.276 0.0645 0.0393 0.0357 0.0354 0.0855 0.113 0.0905 0.048 0.0632 0.039 0.0324 0.274 0.0645 0.0305 0.0332 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 08/18/06 1315 559393 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 08/17/06 1312 559366 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 20 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-132A Project: YANK01204 Sample ID: 169489003 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.21 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-132B 169489004 SE 1 I-AUG-06 17-AUG-06 Client 28.5%Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gammia,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium- 134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 1.08 U 0.147 0.681 0.521 UI 0.00 1.25 3.56 U -0.0214 U 0.0341 U 0.0966 0.903 0.706 U 0.00978 U -0.00758 13.2 0.521 U -0.00177 0.297+/-0.244+/-0.110+/-0.364+/-0.110+/-0.0539+/-0.0738+/-0. 133+/-0.0677+/-0.0832+/-0.0619+/-0.0645+/-0.0984+/-0.0344+/-0.0277+/-0.906+/-0.110+/-0.0264+/-0.0591 0.113 0.0817 0.202 0.0448 0.0325 0.0253 0.0219 0.0569 0.0718 0.0555 0.0321 0.0431 0.0291 0.0232 0.185 0.0448 0.022 0.0236+/-0.244+/-0.110+/-0.364+/-0.110+/-0.0539+/-0.0738+/-0.133+/-0.0677+/-0.0832+/-0.0619+/-0.0645+/-0.0984+/-0.0344+/-0.0277+/-0.906+/-0.110+/-0.0264+/-0.0591 0.233 0.167 0.419 0.0926 0.0671 0.0524 0.0469 0.117 0.152 0.114 0.0657 0.0887 0.0601 0.0481 0.400 0.0926 0.0453 0.0488 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 08/18/06 1315 559393 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 08/17/06 1312 559366 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 22 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-132B Project: YANK01204 Sample ID: 169489004 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.23 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-132C 169489005 SE 11-AUG-06 17-AUG-06 Client 18%Project: Client ID: Vol. Recv.: YANK0 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 lngrowth Waived Actinium-228 0.814 +/-0.152 Americium-241 U 0.0306 +/-0.0879 Bismuth-212 0.532 +/-0.294 Bismuth-214 0.821 +/-0.0975 Cesium- 134 UI 0.00 +/-0.0308 Cesium-137 U 0.0145 +/-0.0195 Cobalt-60 U 0.0226 +/-0.0231 Europium-152 U -0.0194 +/-0.0484 Europium-154 U -0.00311 +/-0.0706 Europium-155 U 0.0612 +/-0.0812 Lead-212 0.865 +/-0.0633 Lead-214 0.945 +/-0.0936 Manganese-54 U 0.028 +/-0.0186 Niobium-94 U -0.0121 +/-0.0182 Potassium-40 10.4 +/-0.911 Radium-226 0.821 +/-0.0975 Silver-108m U -0.00579 +/-0.0171 Thallium-208 0.275 +1-0.0501 0.0601 0.0846 0.117 0.0329 0.0215 0.0179 0.0217 0.043 0.0601 0.0518 0.0279 0.0309 0.0155 0.0147 0.163 0.0329 0.0149 0.0174+/-0.152+/-0.0879+/-0.294+/-0.0975+/-0.0308+/-0.0195+/-0.0231+/-0.0484+/-0.0706+/-0;0812+/-0.0633+/-0.0936+/-0.0186+/-0.0182+/-0.911+/-0.0975+/-0.0171+1-0.0501 0.130 0.174 0.253 0.0699 0.0458 0.0381 0.0471 0.0907 0.130 0.107 0.058 0.0651 0.0334 0.0315 0.364 0.0699 0.0316 0.0369 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 08/18/06 1316 559393 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 08/17/06 1312 559366 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 24 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-132C Project: YANK01204 Sample ID: 169489005 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.25 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-132D 169489006 SE SI1-AUG-06 17-AUG-06 Client 24.4%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.953 +/-0.221 Americium-241 U 0.0091 +/-0.126 Bismuth-212 1.15 +/-0.319 Bismuth-214 0.780 +/-0.0989 Cesium-134 U 0.0515 +/-0.0385 Cesium-137 0.311 +/-0.0437 Cobalt-60 0.431 +/-0.062 Europium-152 U -0.00842 +/-0.0543 Europium-154 U -0.00698 +/-0.0661 Europium-155 U 0.0858 +/-0.061 Lead-212 0.927 +/-0.0645 Lead-214 0.809 +/-0.0949 Manganese-54 U 0.0222 +/-0.0269 Niobium-94 U 0.021 +/-0.020 Potassium-40 11.0 +/-0.892 Radium-226 0.780 +/-0.0989 Silver-108m U -0.00199 +/-0.0198 Thallium-208 0.287 +/-0.0511 0.068 0.084 0.126 0.0349 0.0247 0.0189 0.0153 0.048 0.0549 0.0577 0.0295 0.0368 0.0194 0.0181 0.152 0.0349 0.0172 0.0182+/-0.221+/-0.126+/-0.319+/-0.0989+/-0.0385+/-0.0437+/-0.062+/-0.0543+/-0.0661+/-0.061+/-0.0645+/-0.0949+/-0.0269+/-0.020+/-0.892+/-0.0989+/-0.0198+1-0.0511 0.146 0.173 0.271 0.0738 0.0522 0.0402 0.0342 0.101 0.120 0.119 0.0611 0.0768 0.0413 0.0384 0.341 0.0738 0.0362 0.0386 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 08/18/06 1316 559393 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 08/17/06 1312 559366 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 26 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-132D Proiect: YANKO 1204 Sample ID: 169489006 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.27 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-112A 169489007 SE 14-AUG-06 17-AUG-06 Client 39.6%Project: Client ID: Vol. Recv.: YANKO 1204 YANKOO Parameter Qualifier Result Uncertainty LC TPU MDA .Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gammnia,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.17 +/-0.220 Americium-241 U 0.128 +/-0.116 Bismuth-212 0.828 +/-0.299 Bismuth-214 0.741 +/-0.104 Cesium-134 UI 0.00 +/-0.0571 Cesium-137 2.20 +/-0.0876 Cobalt-60 1.83 +/-0.0987 Europium-152 U -0.0307 +/-0.0725 Europium-154 U 0.00545 +/-0.0739 Europium-155 U -0.0387 +/-0.0683 Lead-212 1.11 +/-0.0677 Lead-214 0.883 +/-0.109 Manganese-54 U 0.00409 +/-0.0279 Niobium-94 U 0.011 +/-0.0235 Potassium-40 14.1 +/-0.876 Radium-226 0.741 +/-0.104 Silver-108m U -0.0107 +/-0.0258 Thallium-208 0.370 +/-0.0475 0.0988 0.0835 0.169 0.0446 0.0293 0.0219 0.0192 0.0592 0.0609 0.0583 0.0321 0.0473 0.0236 0.0203 0.164 0.0446 0.0208 0.0219+/-0.220+/-0.116+/-0.299+/-0.104+/-0.0571+/-0.0876+/-0.0987+/-0.0725+/-0.0739+/-0.0683+/-0.0677+/-0.109+/-0.0279+/-0.0235+/-0.876+/-0.104+/-0.0258+/-0.0475 0.205 0.171 0.352 0.0924 0.0608 0.0457 0.0414 0.122 0.130 0.119 0.0658 0.0972 0.0491 0.0423 0.358 0.0924 0.043 0.0455 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 08/18/06 1316 559393 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 08/17/06 1312 559366 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 28 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-112A Project: YANKO1204 Sample ID: 169489007 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.29 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com 14 -nf A n,1lrcce~.,L.i LR1I~~L~..

'.11 iTkJILtR V ~Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-112B 169489008 SE 14-AUG-06 17-AUG-06 Client 28.7%Project: YANKO 1204 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnna,Solid-FSS 6AM & ALL FSS 226 Ingrowth Waived Actinium-228 1.07 +/-0.147 Americium-241 U 0.0756 +/-0.106 Bismuth-212 0.644 +/-0.196 Bismuth-214 0.703 +/-0.0761 Cesium- 134 U1 0.00 +/-0.0284 Cesium-137 1.48 +/-0.0633 Cobalt-60 0.981 +/-0.0677 Europium-152 U 0.0301 +/-0.0672 Europium-154 U 0.019 +/-0.0512 Europium-155 U 0.0394 +/-0.0692 Lead-212 1.00 +/-0.0537 Lead-214 0.848 +/-0.0763 Manganese-54 U 0.0186 +/-0.0222 Niobium-94 U 0.00178 +/-0.018 Potassium-40 14.2 +/-0.695 Radium-226 0.703 +/-0.0761 Silver-108m U 0.00208 +/-0.0164 Thallium-208 0.301 +/-0.042 0.0548 0.0857 0.108 0.0287 0.0184 0.0143 0.0132 0.041 0.0435 0.0479 0.0236 0.0286 0.0165 0.0131 0.101 0.0287 0.0144 0.0145+/-0.147+/-0.106+/-0.196+/-0.0761+/-0.0284+/-0.0633+/-0.0677+/-0.0672+/-0.0512+/-0.0692+/-0.0537+/-0.0763+/-0.0222+/-0.018+/-0.695+/-0.0761+/-0.0164+/-0.042 0.114 0.176 0.225 0.0594 0.0382 0.0298 0.0281 0.0846 0.0918 0.0982 0.0485 0.0589 0.0342 0.0273 0.219 0.0594 0.0298 0.0302 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 08/18/06 1317 559393 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 08/17/06 1312 559366 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 30 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-112B Project: YANK01204 Sample ID: 169489008 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldo I-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.Ut Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.31 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analvsik Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-112C 169489009 SE 15-AUG-06 17-AUG-06 Client 19.9%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.801 +/-0.180 Americium-241 U 0.0214 +/-0.0414 Bismuth-212 0.465 +/-0.239 Bismuth-214 0.545 +/-0.0847 Cesium-134 UI 0.00 +/-0.0334 Cesium-137 0.746 +/-0.0861 Cobalt-60 0.520 +/-0.0652 Europium-152 U 0.0216 +/-0.045 Europium-154 U -0.0288 +/-0.0508 Europium-155 U 0.0581 +/-0.0468 Lead-212 0.787 +/-0.0899 Lead-214 0.576 +/-0.0834 Manganese-54 U -0.00473 +/-0.0188 Niobium-94 U 0.00483 +/-0.0155 Potassium-40 10.6 +/-0.950 Radium-226 0.545 +/-0.0847 Silver-108m U 0.00971 +/-0.0166 Thallium-208 0.272 +/-0.0457 0.056 0.0394 0.138 0.0288 0.0233 0.0163 0.0152 0.0413 0.0395 0.0439 0.0303 0.0279 0.0162 0.0141 0.112 0.0288 0.015 0.0164+/-0.180+/-0.0414+/-0.239+/-0.0847+/-0.0334+/-0.0861+/-0.0652+/-0.045+/-0.0508+/-0.0468+/-0.0899+/-0.0834+/-0.0188+/-0.0155+/-0.950+/-0.0847+/-0.0166+/-0.0457 0.119 0.0812 0.291 0.0607 0.0487 0.0343 0.0332 0.0862 0.0867 0.0903 0.0623 0.0585 0.0344 0.0299 0.252 0.0607 0.0314 0.0344 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 08/18/06 1317 559393 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 08/17/06 1313 559366 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 32 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-112C Project: YANK0 1204 Sample ID: 169489009 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.33 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0001-1 12D 169489010 SE 15-AUG-06 17-AUG-06 Client 19.6%Proiect: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver- 108m Thallium-208 0.729 U -0.0381 0.574 0.581 UI 0.00 0.542 0.308 U 0.00733 U 0.0297 U 0.0713 0.771 0.672 U 0.00752 U 0.00559 10.9 0.581 U 0.00191 0.236+/-0.146+/-0.0558+/-0.213+/-0.0677+/-0.0226+/-0.0411+/-0.0358+/-0.0366+/-0.0423+/-0.0587+/-0.0446+/-0.071+/-0.0139+/-0.0126+/-0.586+/-0.0677+/-0.0126+/-0.0295 0.0411 +/-0.146 0.0534 +/-0.0558 0.0874 +/-0.213 0.0243 +/-0.0677 0.0156 +/-0.0226 0.0121 +/-0.0411 0.011 +/-0.0358 0.0338 +/-0.0366 0.0377 +/-0.0423 0.0392 +/-0.0587 0.0202 +/-0'0446 0.0227 +/-0.071 0.0127 +/-0.0139 0.0116 +/-0.0126 0.0941 +/-0.586 0.0243 +/-0.0677 0.0114 +/-0.0126 0.0125 +/-0.0295 0.087 0.110 0.184 0.0507 0.0326 0.0255 0.0238 0.0702 0.0803 0.0806 0.0416 0.0471 0.0266 0.0243 0.206 0.0507 0.0238 0.0262 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 08/18/06 1317 559393 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 08/17/06 1313 559366 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported 34 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21,2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0001-112D Project: YANK01204 Sample ID: 169489010 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.35 QUALITY CONTROL DATA 36 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Client : Connecticut Yankee Atomic Power 362 Injun Hollow Rd Report Date: August 21, 2006 Page 1 of 5 East Hampton, Connecticut Contact: Mr. Jack McCarthy Workorder:

169489 Parmname NOM Samule Oual QC Units RPD%REC% Range Anist Date Time Rad Gamma Spec Batch 559393 QC1201161905 Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-152 Europium-I154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 169489001 DUP 1.03 Uncert: +/-0.245 TPU: +/-0.245 U 0.0548 Uncert: +/-0.103 TPU: +/-0.103 UI 0.00 Uncert: +/-0.427 TPU: +/-0.427 0.654 Uncert: +/-0.137 TPU: +/-0.137 U 0.0706 Uncert: +/-0.0524 TPU: +/-0.0524 0.558 Uncert: +/-0.0668 TPU: +/-0.0668 1.66 Uncert: +/-0.124 TPU: +/-0.124 U -0.0057 Uncert: +/-0.0712 TPU: +/-0.0712 U -0.0388 Uncert: +/-0.0741 TPU: +/-0.0741 UI 0.00 Uncert: +/-0.111 TPU: +/-0.111 0.799 Uncert: +/-0.0747 TPU: +/-0.0747 0.805 Uncert: +/-0.123 TPU: +/-0.123 U -0.000465 Uncert: +/-0.0303 TPU: +/-0.0303 U -0.00327 Uncert: +/-0.0264 TPU: +/-0.0264 0.939+/-0.174+/-0.174 U 0.153+/-0.118+/-0.118 0.672+/-0.252+/-0.252 0.799+/-0.0914+/-0.0914 UI 0.00+/-0.0359+/-0.0359 0.562+/-0.0427+/-0.0427 1.72+/-0.087+/-0.087 U -0.0116+/-0.0537+/-0.0537 U -0.0661+/-0.0619+/-0.0619 U 0.0287+/-0.052+/-0.052 1.01+/-0.0574+/-0.0574 0.946+/-0.0832+/-0.0832 U 0.00889+/-0.0174+/-0.0174 U 0.00534+/-0.0181+/-0.0181 pCi/g 10 pCi/g 95 (0%- 100%) MJHI 08/18/06 16:29 (0%- 100%)pCi/g 13* (0%- 100%)pCi/g 20 pCi/g 24 pCi/g I pCi/g 3 pCi/g 68 pCi/g 52 pCi/g 136 pCi/g 24 pCi/g 16 pCi/g 222 pCi/g 833 (0%- 100%)(0%- 100%)(0%- 100%)(0% -20%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 20%)(0%- 20%)(0%- 100%)(0% -100%)37 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

169489 Page 2 of 5 Parmname NOM SamDle Oual QC Units RPD%REC% Range Anist Date Time Rad Gamma Spec Batch 559393 Potassium-40 Radium-226 Silver- 108m Thallium-208 QC1201161906 Actinium-228 Americium-241 Bismuth-212 11.3 Uncert: +/-1.02 TPU: +/-1.02 0.654 Uncert: +/-0.137 TPU: +/-0.137 U 0.00854 Uncert: +/-0.0236 TPU: +/-0.0236 0.394 Uncert: +/-0.0629 TPU: +/-0.0629 LCS Bismuth-214 Cesium-134 Cesium-137 Uncert: TPU: 23.4 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 9.58 Uncert: TPU: 14.6 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 12.9+/-0.740+/-0.740 0.799+/-0.0914+/-0.0914 U -0.0148+/-0.0167+/-0.0167 0.332+/-0.0441+/-0.0441 U 0.692+/-0.624+/-0.624 25.5+/-1.42+/- 1.42 U 0.670+/-1.36+/-1 .36 U 0.0325+/-0.247+/-0.247 U -0.00147+/-0.156+/-0.156 9.55+/-0.496+/-0.496 15.6+/-0.680+/-0.680 U 0.193+/-0.310+/-0.310 U -0.0809+/-0.407+/-0.407 U -0.0999+/-0.330+/-0.330 U 0.0195+/-0.167+/-0.167 U -0.188+/-0.225 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 08/18/06 16:30 pCi/g 13 pCi/g 20 pCi/g 748 pCi/g 17 109 (75%-125%)

(0% -20%)(0%- 100%)(0%- 100%)(0%- 100%)100 (75%-125%)

107 (75%-125%)

Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Uncert: 38 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

169489 Page 3 of 5 Parmname NOM Samnie Onal OC Units RPD%REC% Range Anist Date Time Rad Gamma Spec Batch 559393 REC% Ranpe Anist TPU: Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver- 108m Thallium-208 QCI201161904 Actinium-228 Amnericium-241 MB Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert'TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-0.225 U -0.037+/-0.167+/-0.167 U 0.00951+/-0.128+/-0.128 U -0.215+/-1.21+/-1.21 U 0.0325+/-0.247+/-0.247 U 0.0256+/-0.118+/-0.118 U -0.021+/-0.129+/-0.129 U 0.0529+/-0.0385+/-0.0385 U 0.00443+/-0.0405+/-0.0405 U 0.0079+/-0.0865+/-0.0865 U 0.0138+/-0.0472+/-0.0472 U -0.00723+/-0.00999

+/-0.00999 U -0.00436+/-0.0111+/-0.0111 U 0.00225+/-0.0112+/-0.0112 U -0.00921+/-0.028+/-0.028 U 0.00916+/-0.0359+/-0.0359 U -0.0231 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g (75%-125%)

08/18/06 16:29 Bismuth-212 Bismuth-214 Cesium- 134 Cesium-137 Cobalt-60 Europiumn-152 Europium-154 Europium-155 39 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

169489 Page 4 of 5 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 559393 Uncert: +/-0.0264 TPU: +/-0.0264 Lead-212 U 0.000175 pCi/g Uncert: +/-0.0255 TPU: +/-0.0255 Lead-214 U 0.0241 pCi/g Uncert: +/-0.023 TPU: +/-0.023 Manganese-54 U -0.0049 pCi/g Uncert: +/-0.0123 TPU: +/-0.0123 Niobium-94 U -0.0093 pCi/g Uncert: +/-0.0127 TPU: +/-0.0127 Potassium-40 U 0.0553 pCi/g Uncert: +/-0.228 TPU: +/-0.228 Radium-226 U 0.0138 pCi/g Uncert: +/-0.0472 TPU: +/-0.0472 Silver-108m U 0.00363 pCi/g Uncert: +/-0.0106 TPU: +/-0.0106 Thallium-208 U 0.00849 pCi/g Uncert: +/-0.0123 TPU: +/-0.0123 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 40 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

169489 Page 5 of 5 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.** Indicates analyte is a surrogate compound.^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.41 Table of Contents G eneral Narrative

..................................................................

1 Chain of Custody and Supporting Documentation

...........

5 Data Review Qualifier Definitions

.......................................

12 Radiological Analysis ..........................................................

14 Sam ple Data Sum m ary ......................................................

30 Q uality C ontrol D ata ...........................................................

35 General Narrative 1 General Narrative for Connecticut Yankee Atomic Power Co.Work Order: 173770 SDG: MSR#06-1130 October 16, 2006 Laboratory Identification:

General Engineering Laboratories, LLC 2040 Savage Road Charleston, South Carolina 29407 (843) 556-8171 Summary Sample receipt The sample arrived at General Engineering Laboratories, LLC, Charleston, South Carolina on August 17, 2006 for analysis.

Shipping container temperature was checked, documented, and within specifications.

The sample was delivered with proper chain of custody documentation and signatures.

All sample containers arrived without any visible signs of tampering or breakage.Sample Identification The laboratory received the following sample: Laboratory Sample Identification Description 173770001 9106-0001-112F Items of Note Dale Randall requested FSSALL (sans gamma) be analyzed on the sample above via email on 10/11/06.Case Narrative Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures.

Any technical or administrative problems during analysis, data review, and reduction are contained in the analytical case narratives in the enclosed data package.Analytical Request One soil sample was reanalyzed for FSSALL, sans gamma.Data Package The enclosed data package contains the following sections:

General Narrative, Chain of Custody and Supporting Documentation, Data Review Qualifier Definitions, and data from the following fractions:

Radiochemistry.

2 I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Chect Maones Project Manager 3 List of current GEL Certifications as of 16 October 2006 State ] Certification Alaska I UST-062 Arizona AZ0668 Arkansas j 88-0651 CLIA 42D0904046 California 01151CA Colorado GenEngLabs Connecticut PH-0169 Dept. of Navy NFESC 413 F EPA WG-15J Florida/NELAP E87156 Georgia E87156 (FL/NELAP)

Hawaii N/A Idaho N/A Illinois 200029 Indiana C-SC-01 Kansas T E-10332 Kentucky 90129 Louisiana j 03046 Maryland 270 Massachusetts M-SCO12 Michigan 9903 Nevada SC12 New Jersey SCO02 New Mexico FL NELAP E87156 New York 11501 North Carolina 233 North Carolina Drinking W North Dakota Oklahoma Pennsylvania South Carolina Tennessee Texas 45709 R-158 9904 68-00485 10120001/10585001/10120002 02934 TX213-2006A Texas NELAP T104704235-06-TX U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer 1 N/A Utah 1 8037697376 GEL Vermont 1 VT87156 Virginia 00151 Washington

] C1641 4 Chain of Custody and Supporting Documentation 5

Health Phýsics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00496 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested

'T.aij 1U6 ~YRx Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3924 JJ?:17>Analytical Lab (Name, City, State) (VUA F General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones II Priority:

30 D. 14 D. -- 7 D. Z 3 D.Container z ore',Peevto peJ).Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation C "ab Sample ID Code Code Code 9106-0001-132F____

SE C BP X ____________-

9106-0001-112F SE C BP X .:.9106-0001-132A s______SE C BP X ..._________.__

9106-0001-132B SE C BP X 9106-0001-132C SE C BP X ---___________

9106-0001-132D SE C BP X 9106-0001-112A SE C BP X 9106-0001-1 12B _____ SE C BP X 9106-0001-1 12C _________

SE C BP X NOTES: PO #: 002332 MSR #: 06- t7Co SSWP# NA U LTP QA [ Radwaste QA [ Non QA Samples Shipped Via: ._In e onta~er[ Fed Ex Temp- De.LIUPS C E] Hand i §aled?..1) Relinquished By Date/Time

2) Received By D ,te/Time Custody Seal JI310 -14~ -e 0-/6 /5 2 -.I]Other to/3) Relinquished By Date/Time
4) Received By Date/Time N-:.____________

b Bill of Lading 5) Relinquished By Date/Time

6) Received By Date/Time
7u/ Cl 0 Y)30 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00497 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested

-Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3924 Analytical Lab (Name, City, State) .General Engineering Laboratories 2040 Savage Road, Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones oo Priority:

E'-30 DRE 14D.j I-7D. 0 3D.Container Sample Size- Comment, Preservation

$ Laap t)Sample Designation Date Time Media Type &Type "me.t, Psvi La .. ' ., Code Code Code 9106-0001-112D SE C BP X NOTES: PO #: 002332 MSR #: 06- ti .c SSWP# NA Z LTP QA FE Radwaste QA nl Non QA Samples Shipped Via-. , i,, FedEx L UPS ElHand tU Sde?1) Relinquished By Date/Time

2) Received By Date/Time

'Clul 'Uidy¢i d.rt4A4F~

-/o /fAA .E Other nat 3) Relinquished By Date/Time

4) Received By Date/Time

___._________,_

_ YII 4 .Bill of Lading #5) Relinquished By Date/Time

6) Received By Date/Time 0 150/ ,/j9 3 46Uv Connecticut Yankee -C-SO-O01 Statement of Work for Analytical Lab Services Figure 1. Sample Check-in List DatelfimfteReceived:

..... , , SDG#: .Work order Number: -18 1 Z, Shipping C_3ntainer ID: .qzj S/_f Chain of Custody#..

Z"G " %0 1. Custody Seals ozi shipping container intact?... -Yes t ] No (JI 2. Custody Seals dated and signed? Yesj 1, No 3. Chain-of-Custo'y record present? Yes W ]4. Cooler temperature 2 #..5. Vermiculite/packing materials is: Wet [%'iry t, j 6 Number of samples in shipping container:

/0 -.. mPL($7. Sample holding times exceeded?

Yes [ No [1 8.. Samples have:'_ý _-____hazard labels-2custady seals -appropriate sample labels 9. Samples arei_ý"in good condition -leaking-broken -have air bubbles 10, Were any anomalies identified in sample receipt? Yes[] No " ii. Description of anomalies (include sample numbers):

on7 C--.Sample CustodiadLaboratory: .e. ," Date: D 7 Telephoned to; on _ B 8 RE: Please send your request for analysis

Subject:

RE: Please send your request for analysis From: "Dale Randall" <randall@cyapco.com>

Date: Wed, 11 Oct 2006 09:21:19 -0400 To: "Cheryl Jones" <cj@gel.com>

CC: "Arthur L. Hammond" <Hammond@CYAPCO.com>, "John McCarthy" <McCarthy@CYAPCO.com>

Sorry, old habits die hard, it is: 9106-0001-I12F


Original Message -----From: Cheryl Jones (mailto:cj@gel.com]

Sent: Wednesday, October 11, 2006 9:17 AM To: Dale Randall Cc: Arthur L. Hammond; John McCarthy

Subject:

Re: Please send your request for analysis Dale, Please confirm that ID. Our system lists MSR#06-1130 as containing the following IDs: 9106-0001-132F 9106-0001-112F 9106-0001-132A 9106-0001-132B 9106-0001-132C 9106-0001-132D 9106-0001-112A 9106-0001-112B 9106-0001-112C 9106-0001-112D I will check with the lab on the available TAT and let you know yet this morning.Thanks, Cheryl Dale Randall wrote: Cheryl, The Sample ID is 9106-0001-012F, to be tested for FSSALL. This sample has been tested to the FSSGAM protocol as part of MSR#06-1130, COC#2006-00496.

Can this be done on a 7-day turn?Thank you, Dale Randall FSS Engineer Connecticut Yankee (860) 267-3133----- Original Message -----From: Cheryl Jones [1]

Sent: Tuesday, October 10, 2006 5:30 PM To: Dale Randall

Subject:

Please send your request for analysis Dale, I was interrupted while listening to the voice mail you left me this 9 I of 2 10/17/2006 2:59 PM RE: Please send your request for analysis afternoon and somehow deleted it. Could you please send me the ID that you need and the analysis?

I apologize for the inconvenience.

Thanks, Cheryl Cheryl A. Jones Project Manager/PM Team Leader General Engineering Laboratories, LLC 2040 Savage Road Charleston, SC (USA) 29407 Direct: 843.769.7388 Main: 843.556.8171 x 4243 Fax: 843.766.1178 E-mail: cj@gel.com Web: www.gellcom The information contained in this message is confidential and is intended only for the use of the individual or firm of record. If you are not the intended recipient and have received this message in error, you are asked not to copy or distribute any of the pages that follow. Please notify the sender immediately by telephone or email if you have received this communication in error and destroy the contents that do not pertain to your business with The GEL Group, INC.10 2 of 2 10/17/2006 2:59 PM SAMPLE RECEIPT & REVIEW FORM CONTINUATION FORM&r lO~ cA- --I'!7..., r ' 'i-c,, TP c ( Colm r.-c,-D r --- nA- 'Q 0 lt -- 13 2- C, ICs-.5 9 lo- -I-n 10 q 10OU --b1- t,-O o -5 0l(t,-- i i% B-io-o 1- elloum -B12.} >i.- ot -7 i -,is cl lo(r --11S7,4- _cl I0Q -- It1'L- D E1 -Ob'.4q$q~ 0o7, ýLP o.s 9 L ot --00"53 t! w f--,, _ .m q loo06- UK&- ow, I,-W oq (Xv --= 0o~l u5Ioo /4'#:395 11 Data Review Qualifier Definitions 12 Data Review Qualifier Definitions Qualifier Explanation

  • A quality control analyte recovery is outside of specified acceptance criteria** Analyte is a surrogate compound* Result is less than value reported* Result is greater than value reported-RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank B Metals-Either presence of analyte detected in the associated blank, or MDL/IDL < sample value < PQL BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample d 5-day BOD-The 2:1 depletion requirement was not met for this sample E Organics-Concentration of the target analyte exceeds the instrument calibration range E Metals-%difference of sample and SD is >10%. Sample concentration must meet flagging criteria H Analytical holding time was exceeded h Preparation or preservation holding time was exceeded J Value is estimated N Metals-The Matrix spike sample recovery is not within specified control limits N Organics-Presumptive evidence based on mass spectral library search to make a tentative identification of the analyte (TIC). Quantitation is based on nearest internal standard response factor N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the reporting limit UI Gamma Spectroscopy-Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound Z Paint Filter Test-Particulates passed through the filter, however no free liquids were observed.GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.P.O. BOX 30712 Charleston, SC 29417 -2040 Savage Road (29407)Phone (843) 556-8171
  • Fa(IA3) 766-1178 www.gel.com RADIOLOGICAL ANALYSIS 14 Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)Work Order 173770 Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: Prep Method: DOE EML HASL-300, Am-05-RC Modified Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 578392 578049 578048 Sample ID 173770001 1201205231 1201205232 1201205233 1201205234 Client ID 9106-0001-112F Method Blank (MB)173770001(9106-0001-112F)

Sample Duplicate (DUP)173770001(9106-0001-112F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

15 Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 173770001 (9106-0001-112F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information 16 Product: Alphaspec Pu, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu-1 1-RC Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 578394 578049 578048 Sample ID 173770001 1201205235 1201205236 1201205237 1201205238 Client ID 9106-0001-112F Method Blank (MB)173770001(9106-0001-1 12F) Sample Duplicate (DUP)173770001(9106-0001-112F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 173770001 (9106-0001-112F).

QC Information All of the QC samples met the required acceptance limits.17 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu-1i -RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 578398 Prep Batch Number: 578049 Dry Soil Prep GL-RAD-A-021 Batch Number: 578048 18 Sample ID Client ID 173770001 9106-0001-112F 1201205248 Method Blank (MB)1201205249 173770001(9106-0001-112F)

Sample Duplicate (DUP)1201205250 173770001(9106-0001-112F)

Matrix Spike (MS)1201205251 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 173770001 (9106-0001-112F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this 19 SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: GFPC, Sr90, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 578500 578049 578048 Sample ID 173770001 1201205511 1201205512 1201205513 1201205514 Client ID 9106-0001-112F Method Blank (MB)173770001(9106-0001-112F)

Sample Duplicate (DUP)173770001(9106-0001-112F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).20 Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 173770001 (9106-0001-112F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number: 578363 21 Sample ID Client ID 173770001 9106-0001-112F 1201205177 Method Blank (MB)1201205178 173770001(9106-0001-112F)

Sample Duplicate (DUP)1201205179 173770001(9106-0001-112F)

Matrix Spike (MS)1201205180 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 173770001 (9106-0001-112F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation 22 Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Fe55, Solid-ALL FSS DOE RESL Fe-1, Modified Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 578445 578049 578048 Sample ID 173770001 1201205350 1201205351 1201205352 1201205353 Client ID 9106-0001-112F Method Blank (MB)173770001(9106-0001-112F)

Sample Duplicate (DUP)173770001(9106-0001-112F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry 23 All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 173770001 (9106-0001-112F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information 24 Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: DOE RESL Ni-1, Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 578448 578049 578048 Sample ID 173770001 1201205362 1201205363 1201205364 1201205365 Client ID 9106-0001-112F Method Blank (MB)173770001(9106-0001-112F)

Sample Duplicate (DUP)173770001(9106-0001-1 12F) Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 173770001 (9106-0001-112F).

QC Information All of the QC samples met the required acceptance limits.25 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Analytical Method: Analytical Batch Number: Sample ID 173770001 1201205181 1201205182 1201205183 1201205184 LSC, Tritium Dist, Solid-HTD2,ALL FSS EPA 906.0 Modified 578364 Client ID 9106-0001-112F Method Blank (MB)173770001(9106-0001-112F)

Sample Duplicate (DUP)173770001(9106-0001-112F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 13.26 Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QCQ Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 173770001 (9106-0001-112F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information 27 Product: Liquid Scint C14, Solid AII,FSS Analytical Method: Analytical Batch Number: Sample ID 173770001 1201205173 1201205174 1201205175 1201205176 EPA EERF C-01 Modified 578362 Client ID 9106-0001-112F Method Blank (MB)173435001(9520-0003-039F)

Sample Duplicate (DUP)173435001(9520-0003-039F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 173435001 (9520-0003-039F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.28 Sample Re-prep/Re-analysis The background was recounted due to high MDAs.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator.

In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.The following data validator verified the information presented in this case narrative:

Reviewer/Date:

CA Y- 0 011 li/ 10 Q 29 SAMPLE DATA

SUMMARY

30 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Report for YANKOO1 Connecticut Yankee Atomic Power Co.Client SDG: MSR#06-1130 GEL Work Order: 173770 The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria** Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.ND The analyte concentration is not detected above the detection limit.The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures.

Please direct any questions to your Project Manager, Cheryl Jones.Reviewed by 31 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: 9106-0001-112F Proiect: YANK01204 Sample ID: 173770001 Client ID: YANKOO Matrix: TS Vol. Recv.: Collect Date: 02-AUG-06 Receive Date: 17-AUG-06 Collector:

Client Moisture:

38.5%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 0.0478 Curium-242 U 0.00985 Curium-243/244 U 0.0199 Alphaspec Pu, Solid-ALL FSS Plutonium-238 0.0551 Plutonium-239/240 U 0.0257 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 0.274 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.00433 Rad Liquid Scintillation Analysis LSC, Tritiumn Dist, Solid-HTD2,ALL FSS Tritium U 1.60 Liquid Scint C14, SolidAll,FSS Carbon-14 0.267 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -10.1 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -2.53 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.222+/-0.0378+/-0.0193+/-0.0247+/-0.0409+/-0.0291+/-1.93 0.00908 0.00 0.00646 0.00929 0.00928 1.61+/-0.0383+/-0.0193+/-0.0248+/-0.0413+/-0.0292+/-1.93 0.0375 0.0267 0.0324 0.0384 0.0384 3.36 0.0389 10.1 0.187 32.1 16.2 0.500 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MXA I MXA I 10/16/06 0853 578392 1 10/15/06 0837 578394 2 MXA 10/17/06 1559 578398 3 1 TC1 10/17/06 0743 578500 4+/-0.0204 0.0164 +/-0.0204+/-5.76+/-0.116+/-21.2+/-9.07+/-0.296 4.73 0.0912 15.5 7.73 0.242+/-5.76+/-0.116+/-21.2+/-9.07+/-0.296 DFAI AXD2 MXPI MXPI KXR1 10/15/06 0104 578364 10/13/06 1917 578362 10/17/06 2304 578445 10/17/06 1802 578448 10/18/06 0455 578363 5 6 7 8 9 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 AXP2 10/11/06 2056 578048 The following Analytical Methods were performed 32 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: Sample ID: 9106-0001-112F 173770001-Project: YANK01204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu- I -RC Modified 3 DOE EML HASL-300, Pu-I l-RC Modified 4 EPA 905.0 Modified 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-1, Modified 8 DOE RESL Ni-I, Modified 9 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Technetium-99m Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALl Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%83 76 80 69 69 Acceptable Limits (15%-125%)

(15%-I125%)

(25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 33 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: October 18, 2006 Client Sample ID: Sample ID: 9106-0001-112F 173770001 Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.34 QUALITY CONTROL DATA 1.35 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Client: Connecticut Yankee Atomic Power 362 Injun Hollow Rd Renort Date: October 18, 2006 Page 1 of 5 East Hampton, Connecticut Contact: Mr. Jack McCarthy Workorder:

173770 Ni"All I a. a,..c ntnn oai..p.c N.j uaId QC Units RPD%REC% Range Anist Date Time Rad Alpha Spec Batch 578392 QC1201205232 Americium-24 I Curium-242 Curium-243/244 QC 1201205234 Americium-241 173770001 DUP 0.0478 Uncert: +/-0.0378 TPU: +/-0.0383 U 0.60985 Uncert: +/-0.0193 TPU: +/-0.0193 U 0.0199 Uncert: +/-0.0247 TPU: +/-0.0248 LCS Curium-242 Curium-243/244 QC1201205231 MB Americium-241 Curium-242 Curium-243/244 QC1201205233 173770001 MS Americium-24 I Curium-242 Curium-243/244 2.69 Uncert: TPU: Uncert: TPU: 3.24 Uncert: TPU: Uncert: TPU: Unceri: TPU: Uncert: TPU: 0.109+/-0.0598+/-0.0612 U 0.0221+/-0.0338+/-0.0339 U 0.0263+/-0.0445+/-0.0446 2.88+/-0.328+/-0.502 U 0.0195+/-0.027+/-0.0271 3.01+/-0.335+/-0.519 U -0.017+/-0.0116+/-0.0118 U 0.0121+/-0.0193+/-0.0194 U 0.0488+/-0.0482+/-0.0485 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 78 pCi/g 77 pCi/g 28 pCi/g 93 (75%-125%)

(0% -100%) AXAI 10/16/06 08:53 (0%- 100%)(0%- 100%)107 (75%-125%)

2.72 0.0478 Uncert: +/-0.0378 TPU: +/-0.0383 U 0.00985 Uncert: +/-0.0193 TPU: +/-0.0193 3.30 U 0.0199 Uncert: +/-0.0247 TPU: +/-0.0248 U 2.74+/-0.258+/-0.409 0.0286+/-0.0393+/-0.0394 2.75+/-0.260+/-0.411 99 (75%-125%)

83 (75%-125%)

Batch 578394 QC1201205236 173770001 DUP Plutonium-238 0.0551 U 0.00929 pCi/g 142 (0% -100%) AXAI 10/15/06 08:37 36 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

173770 Page 2 of 5 Parmname NOM Sample Qual (C Units RPD%REC% Range Anist Date Time Rad Alpha Spec Batch 578394 Plutonium-239/240 QC1201205238 LCS Plutonium-238 Plutonium-239/240 QC1201205235 MB Plutonium-238 Uncert: +/-0.0409 TPU: +/-0.0413 U 0.0257 Uncert: +/-0.0291 TPU: +/-0.0292 Uncert: TPU: 2.49 Uncert: TPU:+/-0.021+/-0.021 U 0.0328+/-0.0321+/-0.0323 U 0.00764+/-0.0215+/-0.0215 2.81+/-0.282+/-0.441 U -0.00339+/-0.0146+/-0.0146 U -0.0031+/-0.016+/-0.016 pCi/g 24 (0%- 100%)(75%-125%)

Plutonium-239/240 Uncert: TPU: Uncert: TPU: pCi/g pCilg pCilg pCi/g pCilg pCilg 10/15/06 08:37 10/15/06 08:37 113 (75%-125%)

QC1201205237 173770001 MS Plutonium-238 Plutonium-239/240 Uncert: TPU: 2.52 U Uncert: TPU: 0.0551+/-0.0409+/-0.0413 0.0257+/-0.0291+/-0.0292 0.0421+/-0.0369+/-0.0372 2.54+/-0.274+/-0.382 (75%-125%)

101 (75%-125%)

Batch 578398 QC1201205249 173770001 DUP Plutonium-24 l QC1201205251 LCS Plutonium-24 I QC1201205248 MB Plutonium-241 QC1201205250 173770001 MS Plutonium-241 U 0.274 Uncert: +/-1.93 TPU: +/-1.93 U 0.507+/- 1.96+/- 1.96 37.4+/-3.27+/-5.07 pCi/g 0 (0% -100%) v4XA I 35.9 Uncert: TPU: Uncert: TPU: 36.4 U Uncert: TPU: U 0.00+/-1.50 4-/-1.50 pCi/g pCi/g pCi/g 104 (75%-125%)

10/17/06 16:42 10/17/06 17:24 10/17/06 16:20 10/17/06 17:03 0.274+/-1.93+/-1.93 30.9+/-2.68+/-4.01 85 (75%-125%)

Rad Gas Flow Batch 578500 QC1201205512 173770001 DUP Strontium-90 U 0.00433 Uncert: +/-0.0204 U 0.0168+/-0.0206+/-0.0206 pCi/g 0 (0%- 100%) TCI 10/17/06 07:43 37 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

173770 Page 3 of 5 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gas Flow Batch 578500 TPU: +/-0.0204 QCI201205514 LCS Strontium-90 QC1201205511 MB Strontium-90 7.81 Uncert: TPU: Uncert: TPU: 7.65 U Uncert: TPU: 7.63+/-0.241+/-0.312 U -0.0145+/-0.0207+/-0.0207 pCilg pCi/g pCilg 98 (75%-125%)

10/17/06 07:44 10/17/06 07:43 10/17/06 07:43 QC1201205513 173770001 MS Strontium-90 Rad Liquid Scintillation Batch 578362 QC1201205174 173435001 DUP Carbon- 14 QC1201205176 LCS Carbon- 14 QC1201205173 MB Carbon-14 QC1201205175 173435001 MS Carbon- 14 0.00433+/-0.0204+/-0.0204 7.33+/-0.225+/-0.280 96 (75%-125%)

U 0.0477 Uncert: +/-0.111 TPU: +/-0.111 U-0.118+/-0.110+/-0.110 8.66+/-0.265+/-0.297 pCi/g 0 (0% -100%) kXD2 7.27 Uncert: TPU: Uncert: TPU: 7.10 U Uncert: TPU: U -0.0701+/-0.113+/-0.113 pCi/g pCi/g pCi/g 119 (75%-125%)

10/13/06 22:26 10/14/06 00:00 10/13/06 21:38 10/13/06 23:13 0.0477+/-0.111I+/-0. I I Batch 578363 QC1201205178 173770001 DUP Technetium-99 QC1201205180 LCS Technetium-99 QC1201205177 MB Technetium-99 QC1201205179 173770001 MS Technetium-99 U 0.222 Uncert: +/-0.296 TPU: +/-0.296 U 8.27+/-0.257+/-0.287 0.373+/-0.287+/-0.287 12.6+/-0.542+/-0.625 116 (75%-125%)

pCi/g 0 (0% -100%) KXR1 13.0 Uncert: TPU: Uncert: TPU: 13.1 U Uncert: TPU: U 0.179+/-0.238+/-0.238 pCi/g pCi/g pCi/g 97 (75%-125%)

10/18/06 06:00 10/18/06 06:32 10/18/06 05:44 10/18/06 06:16 0.222+/-0.296+/-0.296 12.1+/-0.569+/-0.642 92 (75%-125%)

Batch 578364 38 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Workorder:

173770 Parmname Rad Liquid Scintillation Batch 578364 QC1201205182 173770001 DUP Tritium QC1201205184 LCS Tritium QC1201205181 MB Tritium QC1201205183 173770001 MS Tritium Batch 578445 QC1201205351 173770001 DUP Iron-55 QC1201205353 LCS Iron-55 QCI201205350 MB Iron-55 QC1201205352 173770001 MS Iron-55 Batch 578448 QC1201205363 173770001 DUP Nickel-63 QC1201205365 LCS Nickel-63 QC1201205362 MB Nickel-63 QC1201205364 173770001 MS Nickel-63 QC Summary Sample Qual QC Page 4 of 5 REC% Range Anist Date Time NOM Units RPD%U 1.60 Uncert: +/-5.76 TPU: +/-5.76 10.4 Uncert: TPU: Uncert: TPU: 57.8 U 1.60 Uncert: +/-5.76 TPU: +/-5.76 U -10.1 Uncert: +/-21.2 TPU: +/-21.2 612 Uncert: TPU: Uncert: TPU: 650 U -10.1 Uncert: +/-21.2 TPU: +/-21.2 U -2.53 Uncert: +/-9.07 TPU: +/-9.07 520 Uncert: TPU: Uncert: TPU: 563 U -2.53 Uncert: +/-9.07 U -1.29+/-6.37+/-6.37 9.95+/-1.86+/-1.86 U -0.187+/-1.17+/-1.17 48.5+/-9.94+/-9.97 U -8.61+/-2 1.1+/-21.1 540+/-28.0+/-44.2 U -2.86+/-17.3+/-17.3 549+/-31.4+/-46.9 U -4.02+/-8.95+/-8.95 441+/-20.5+/-25.6 U -4.42+/-8.74+/-8.74 466+/-22.8 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 0 (0% -100%) DFA1 96 (75%-125%)

84 (75%-125%)

0 (0% -100%) vlXPI 88 (75%-125%)

10/15/06 02:10 10/15/06 02:42 10/15/06 01:53 10/15/06 02:26 10/18/06 01:11 10/18/06 02:15 10/18/06 00:40 10/18/06 01:43 10/17/06 19:07 10/17/06 19:40 10/17/06 18:51 10/17/06 19:24 85 (75%-125%)

0 (0% -100%) vAXP1 85 (75%-125%)

83 (75%-125%)

39 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

173770 Page 5 of 5 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Liquid Scintillation Batch 578448 TPU: +/-9.07 +/-28.2 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.** Indicates analyte is a surrogate compound.^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.40 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD Attachment 2b Split Sample Assessment Forms (2 Pages)

Connecticut Yankee Decommissioning Project Health Physics Procedure 24265-000-GPR-GGGR-R5124-000 Attachment A Split Sample Assessment Form Survey Survey 0001 Survey Unit Dis Srey Unit #: Name: Sample Plan or WPIR#: 2006-002 1 SML #: 9106-0001-106 Sample

Description:

Comparison of split samples collected from sample measurement location #106 and analyzed using gamma spectroscopy by an off-site vendor laboratory.

The standard sample was 9106-0001-106F, the comparison sample was 9106-0001-106FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/N)Value Error Range Value Error Ratio Cs-137 1.63E-01 2.24E-02 7 0.5- 2 2.34E-01 2.19E-02 1.44 Y Co-60 1.48E-01 2.33E-02 6 0.5- 2 2.30E-01 2.59E-02 1.55 Y K-40 1.22E+01 5.45E-01 22 0.75- 1.33 1.02E+01 4.05E-01 0.84 Y I I -t I I I I Comments/Corrective Actions: N/A Table is provided to show acceptance criteria used to assess split samples.Resolution Agreement Range 4 8 16 51 7 15 50 200> 200 0.50 0.60 0.75 0.80 0.85 2.00 1.66 1.33 1.25 1.18 Performed By: ,q Z A-"elj WPIR -Work Plan and Inspection Record SML -Sample Measurement Location designation Page I of I Connecticut Yankee Decommissioning Project Health Physics Procedure 24265-000-GPR-GGGR-R5124-000 Attachment A Split Sample Assessment Form Survey Area Survey 0001 Survey Discharge Canal#:9106 Unit#: Unit Name: Sample Plan or WPIR#: 2006-021 SML #: 9106-0001-117 Sample

Description:

Comparison of split samples collected from sample measurement location #04 and analyzed using gamma spectroscopy by an off-site vendor laboratory.

The standard sample was 9106-0001-117F the comparison sample was 9106-0001-117FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/N)Value Error Range Value Error Ratio Cs-137 1.38E-02 8.80E-03 2 NONE -6.46E-03 1.70E-02 0.47 N/A Co-60 5.25E-04 7.65E-03 0 NONE- 3.92E-03 6.70E-03 7.47 N/A K-40 1.01E+01 3.11E-01 32 0.75 1.33 1.03E+01 4.48E-01 1.02 Y+ 1 4 4 ~4 4 4 Comments/Corrective Actions: In consideration of the Cs-137 1Table is provided to show acceptance criteria used and Co-60 results, guidance for agreement ranges, obtained from USNRC Inspection Procedure 84750, does not address resolution ratios less than 4, therefore, a determination of acceptability for such rations cannot be made. Since K-40 was found to be present at an acceptable level of agreement, no further action is warranted.

to assess split samples.Resolution I Agreement Range 4 8 16 51 7 15 50 200> 200 0.50 0.60 0.75 0.80 0.85 2.00 1.66 1.33 1.25 1.18 WPIR -Work Plan and Inspection Record SML -Sample Measurement Location designation Page I of I DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD Attachment 2c Preliminary Data Forms (2 Pages)

Health Physics Procedure GPP-GGGR-R512 1 -001 Attachment B, Rev. CY-00 I MAJOR Preliminary Data Review Form -Samples for the Sign Test Survey Unit: 9106- 0001 Survey Unit Name: Discharge Canal Classification:

2 Survey Media: Soil Type of Survey: Final Status Survey Type of Measurement:

Radionuclide Specific Number of Measurements:

30 Operational DCGL: I BASIC STATISTICAL QUANTITIES Cs-137 Co-60 Minimum Value: -6.78E-04

-4.42E-03 Maximum Value: 2.34E+00 2.65E+00 Mean: 4.54E-01 4.06E-01 Median: 4.23E-01 2.50E-01 Standard Deviation:

4.65E-01 5.68E-01 RADIONUCLIDE CONCENTRATION (pCi/g)NUMBER Cs-137 Co-60 Identified?

Identified?

9106-0001-IOIF 5.04E-01 1.28E-02 Y N 9106-0001-103F 9.09E-01 4.14E-01 Y Y 9106-0001-104F 2.89E-01 3.15E-02 Y Y 9106-0001-106F 1.63E-01 1.48E-01 Y Y 9106-0001-107F 6.95E-01 2.46E-01 Y Y 9106-0001-108F 2.07E-02 1.70E-02 N N 9106-0001-109F

-6.78E-04

-4.42E-03 N N 9106-0001-11OF 6.09E-02 0.OOE+00 Y N 9106-0001-11 IF 1.61E-01 1.14E-01 Y Y 9106-0001-112F 2.34E+00 2.65E+00 Y Y 9106-0001-113F 3.87E-01 2.59E-01 Y Y 9106-0001-114F 7.93E-01 3.70E-01 Y Y 9106-0001-115F 7.60E-01 5.97E-01 Y Y 9106-0001-116F 1.38E-02 3.26E-02 N N 9106-0001-117F 1.38E-02 5.25E-04 N N 9106-0001-119F 2.20E-01 1.12E-01 Y Y 9106-0001-120F 7.39E-01 7.08E-01 Y Y 9106-0001-121F 7.43E-01 6.27E-01 Y Y 9106-0001-122F 4.59E-01 4.22E-01 Y Y 9106-0001-123F 6.77E-01 7.65E-01 Y Y 9106-0001-124F 2.85E-01 2.54E-01 Y Y 9106-0001-125F 2.71E-02 0.OOE+00 Y N 9106-0001-126F 2.44E-01 1.07E-01 Y Y 9106-0001-127F 4.78E-01 7.86E-01 Y Y 9106-0001-128F 9106-0001-129F 9106-0001-130F 9106-0001-13 1F 9106-0001-132F 9106-0001-133F 8.50E-01 6.1OE-02 0.OOE+00 5.66E-01 5.58E-01 6.08E-01 8.18E-01-3.30E-03 0.OOE+00 2.58E-01 1.66E+00 7.84E-01 Y Y N Y Y Y Y N N Y Y Y Performed By: / Independent Review: Date: Date: ///5-DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD Attachment 2d Graphical Representation of Data (4 Pages)

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Health Physics Procedure GGGR-R5 123-Rev.CY-OO1 Attachment C Quantile Plot For Cesium -137 Survey Unit: 9106-0001 Survey Unit Name: Discharge Canal Mean: 4.54E-01 pCi/g 2.50E+00-2.OOE+00 , , , 1.50E+00 0" O.00E+00 ,- .A 6 2 .0 60 80,-5.OOE-01

-Percentage Cs-137 Rank Percentage Cs-137 Rank Percentage

-6.78E-04 0.OOE+00 1.38E-02 1.38E-02 2.07E-02 2.71 E-02 6.09E-02 6.10E-02 1.61E-01 1.63E-01 2.20E-01 2.44E-01 2.85E-01 2.89E-01 3.87E-01 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 2%5%8%12 %15 %18 %22 %25 %28 %32 %35 %38 %42 %45 %48 %4.59E-01 4.78E-01 5.04E-01 5.58E-01 5.66E-01 6.08E-01 6.77E-01 6.95E-01 7.39E-01 7.43E-01 16 17 18 19 20 21 22 23 24 25 52 %55 %58 %62 %65 %68 %72 %75 %78 %82 %85 %88 %92 %95 %98 %7.60E-01 26 7.93E-01 8.50E-01 9.09E-01 2.34E+00 27 28 29 30 Prepared By: Reviewed By: t(5A~ zi-Date: //- -'Date: / /

Quantile Plot For Cobalt -60 Survey Unit: Survey Unit Name: Mean: 9106-0001 Discharge Canal 4.06E-0 1 pCi/g 3.OOE+00 2.50E+00 o 2.OOE+001.50E+00 0 1.OOE+00 E- 5.OOE-01 0 0.OOE+00-5.OOE-01 Percentage Co-60 Rank Percentage Co-60 Rank Percentage

-4.42E-03-3.30E-03 0.OOE+00 0.OOE+00 0.OOE+00 5.25E-04 1.28E-02 1.70E-02 3.15E-02 3.26E-02 1.07E-01 1.12E-01 1.14E-01 1.48E-01 2.46E-01 1 2%2 5%3 8%4 12%5 15%6 18%7 22 %8 25%9 28%10 32 %11 35%12 38 %13 42%14 45%15 48%2.54E-01 2.58E-01 2.59E-01 3.70E-01 4.14E-01 4.22E-01 5.97E-01 6.27E-01 7.08E-01 7.65E-01 7.84E-01 7.86E-01 8.18E-01 1.66E+00 2.65E+00 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 52 55 58 62 65 68 72 75 78 82 85 88 92 95 98%/0 Prepared By: Reviewed By: Date: /- -Date: /-- O Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Cesium -137 Survey Unit: 9106-0001 Survey Unit Name: Discharge Canal Mean: 0.454 pCi/g Upper End Observation Observation Value Frequency Frequency 0 2 7%0.5 15 50%1 12 40%1.5 0 0%2 0 0%2.5 1 3%Total 30 100%Prepared By: 9/117 Date: Date: //-/Q-6 Reviewed By:

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Co -60 Survey Unit: 9106-0001 Survey Unit Name: Discharge Canal Mean: 0.406 pCi/g 20 ,15 Cr u- 5 -.: 0 0 ' I --Ii 0.00 0.50 1.00 1.50 2.00 2.50 3.00 Upper End Value (pCi/g)Upper End Observation Observation Value Frequency Frequency 0.00 5 17%0.50 16 53%1.00 7 23%1.50 0 0%2.00 1 3%2.50 0 0%3.00 1 3%Total 30 100%Prepared By: Date: Reviewed By: Date: / /-I -O~Reviewed By: Date:

DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD Attachment 2e Sign Test Calculation (2 Page)

Health Physics Procedure GPP-GGGR-R512 1 -000 Attachment A, Rev. CY-00 I MAJOR Sign Test Calculation Sheet For Multiple Radionuclisdes Survey Unit Number: 9106-0001 Survey Unit Name: Discharge Canal WP&IR#: 2006-021 Classification

1 TYPE I (cc error):0.05 ITYPE I (P3 error):0.05 Radionuclides:

Survey Design DCGL (pCi/g): Cs-137 Co-60 5.38 2.59 Results Cs-137 5.04E-0 1 9.09E-0 I 2.89E-01 1.63E-01 6.95E-01 2.07E-02-6.78E-04 6.09E-02 1.61E-01 2.34E+00 3.87E-01 7.93 E-0 1 7.60E-0 1 1.38E-02 1.38E-02 2.20E-01 7.39E-01 7.43E-01 4.59E-01 6.77E-0 1 2.85E-01 2.7 1E-02 2.44E-0 1 4.78E-01 8.50E-01 6.1OE-02 0.OOE+00 5.66E-0 1 5.58E-01 6.08E-01 Results Co-60 1.28E-02 4.14E-01 3.15E-02 1.48E-01 2.46E-0 1 1.70E-02-4.42E-03 0.00E+00 1.14E-01 2.65E+00 2.59E-01 3.70E-0 1 5.97E-01 3.26E-02 5.25E-04 1.12E-01 7.08E-01 6.27E-0 1 4.22E-0 1 7.65E-01 2.54E-01 0.OOE+00 1.07E-01 7.86E-01 8.18E-01-3.30E-03 0.OOE+00 2.58E-01 1.66E+00 7.84E-01 Weighted Sum (W,)1.58E-01 3.88E-01 1.25E-01 1.47E-0 1 2.83E-01 6.95E-02 5.73E-02 7.04E-02 1.33E-01 1.53E+00 2.3 1E-01 3.49E-01 4.3 1E-01 7.43E-02 6.19E-02 1.43E-01 4.70E-0 1 4.04E-0 1 3.07E-0 1 4.80E-01 2.1OE-01 6.42E-02 1.46E-01 4.51E-01 5.33E-0 1 6.92E-02 5.91E-02 2.64E-0 1 8.29E-01 4.75E-0 1 DCGL-Result 8.42E-0 1 6.12E-01 8.75E-0 1 8.53E-01 7.17E-01 9.30E-01 9.43E-01 9.30E-0 1 8.67E-0 1-5.27E-0 1 7.69E-0 1 6.51E-01 5.69E-0 1 9.26E-01 9.38E-01 8.57E-01 5.30E-01 5.96E-0 1 6.93E-01 5.20E-01 7.90E-0 1 9.36E-01 8.54E-0 1 5.49E-0 1 4.67E-0 1 9.3 1E-01 9.41E-01 7.36E-01 1.71E-01 5.25E-01 C-14 3.85 Sign 1 1 1 1 1 1 Number of Positive Differences (S+): 29 Page 1 of 2 Health Physics Procedur Critical Value: GPP-GGGR-R5121-000 Attachment A, Rev. CY-001 MAJOR Survey Unit: Meets Acceptance Criterion 19 Performed By: _ _ _ _ _ _ _ _Independent Review: Date: Date: Page 2 of 2 DISCHARGE CANAL SURVEY UNIT 9106-0001 RELEASE RECORD Attachment 2f COMPASS DQA Surface Soil Report with Retrospective Power Curve (5 Pages)

DQA Surface Soil Report Assessment Summary Site: Planner(s):

Survey Unit Name: Report Number: Survey Unit Samples: Reference Area Samples: Test Performed:

Judgmental Samples: Assessment

==

Conclusion:==

9106-0001 17 mrem/yr w/HTDs Dale Randall 9106-0001 17 mrem/yr w/HTDs 1 30 0 Sign Test Result: Pass 0 EMC Result: Not Performed Reject Null Hypothesis (Survey Unit PASSES)Retrospective Power Curve a a I-U I-I;.C, i L E 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0+/- __4 -_____ _____4 -___ _____ _____ I _____T -____________

____________

4 -____________

____________

T -________4-4 _______ -____________

____________

____________

I -__4 -_____I_- 'A-______ ______ zzzt\ ______I ___ -_____0.2 0.4 0.6 0.8 1.0 Unity Rule Sum-of-Ratios, including background

--Prospective Power 1 1-beta ....Actual Power-LBGR --Estimated Power DCGL ---- Retrospective Power 1.2 COMPASS v11.0.0 Page 1 DQA Surface Soil Report Survey Unit Data NOTE: Type = "S" indicates survey unit sample.Type = "R" indicates reference area sample.Sample Number 9106-0001-101F 9106-0001-103F 9106-0001-104F 9106-0001-106F 9106-0001-107F 9106-0001-108F 9106-0001-109F 9106-0001-11OF 9106-0001-111F 9106-0001-112F 9106-0001-113F 9106-0001-114F 9106-0001-115F 9106-0001-116F 9106-0001-117F 9106-0001-119F 9106-0001-120F 9106-0001-121 F 9106-0001-122F 9106-0001-123F 9106-0001-124F 9106-0001-125F 9106-0001-126F 9106-0001-127F 9106-0001-128F 9106-0001-129F 9106-0001-130F 9106-0001-131F 9106-0001-132F 9106-0001-133F Type S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S C-14 (pCl/g)0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.27 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.09 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.32 0.23 Co-60 (pCi/g)0.01 0.41 0.03 0.15 0.25 0.02 0 0 0.11 2.65 0.26 0.37 0.6 0.03 0 0.11 0.71 0.63 0.42 0.76 0.25 0 0.11 0.79 0.82 0 0 0.26 1.66 0.78 Cs-137 (pCi/g)0.5 0.91 0.29 0.16 0.7 0.02 0 0.06 0.16 2.34 0.39 0.79 0.76 0.01 0.01 0.22 0.74 0.74 0.46 0.68 0.28 0.03 0.24 0.48 0.85 0.06 0 0.57 0.56 0.61 COMPASS v1.0.0 Page 2 DQA Surface Soil Report Modified Data (Unity Rule SOR)NOTE: Type = "S" indicates survey unit sample.Type = "R" indicates reference area sample.Sample Number 9106-0001-101F 9106-0001-103F 9106-0001-104F 9106-0001-106F 9106-0001-107F 9106-0001-108F 9106-0001-109F 9106-0001-11OF 9106-0001-111F 9106-0001-112F 9106-0001-113F 9106-0001-114F 9106-0001-115F 9106-0001-116F 9106-0001-117F 9106-0001-119F 9106-0001-120F 9106-0001-121F 9106-0001-122F 9106-0001-123F 9106-0001-124F 9106-0001-125F 9106-0001-126F 9106-0001-127F 9106-0001-128F 9106-0001-129F 9106-0001-130F 9106-0001-131F 9106-0001-132F 9106-0001-133F Type S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S Sum-of-Ratios (SOR)0.16 0.39 0.12 0.15 0.28 0.07 0.06 0.07 0.13 1.53 0.23 0.35 0.43 0.07 0.06 0.14 0.47 0.4 0.31 0.48 0.21 0.06 0.15 0.45 0.53 0.07 0.06 0.26 0.83 0.47 COMPASS vl.0.0 111612006 Page 3 W DQA Surface Soil Report Basic Statistical Quantities Summary Statistic Survey Unit Background DQO Results Sample Number 30 N/A N=15 Mean (SOR) 0.30 N/A 0.35 Median (SOR) 0.22 N/A N/A Std Dev (SOR) 0.30 N/A 0.28 High Value (SOR) 1.53 N/A N/A Low Value (SOR) 0.06 N/A N/A Statistical Test Summary S+: 29 Critical Value: 20 Result: Pass Data DCGLw -Data Sign 0.16 0.84 +0.39 0.61 +0.12 0.88 +0.15 0.85 +0.28 0.72 +0.07 0.93 +0.06 0.94 +0.07 0.93 +0.13 0.87 +1.53 -0.53 0.23 0.77 +0.35 0.65 +0.43 0.57 +0.07 0.93 +0.06 0.94 +0.14 0.86 +0.47 0.53 +0.4 0.60 +0.31 0.69 +0.48 0.52 +0.21 0.79 +0.06 0.94 +0.15 0.85 +0.45 0.55 +0.53 0.47 +0.07 0.93 +0.06 0.94 +COMPASS vl.0.0 111612006 Page 4

/DQA Surface Soil Report Statistical Test Summary Data 0.26 0.83 0.47 DCGLw -Data 0.74 0.17 0.53 Sign+++COMPASS v1.0.0 111612006 Page 5