Line 3: Line 3:
| issue date = 12/07/2011
| issue date = 12/07/2011
| title = Annual Report on Westinghouse Electric Company LLC Combustion Engineering Emergency Core Cooling System Performance Evaluation Models
| title = Annual Report on Westinghouse Electric Company LLC Combustion Engineering Emergency Core Cooling System Performance Evaluation Models
| author name = Steelman W J
| author name = Steelman W
| author affiliation = Entergy Nuclear South, Entergy Operations, Inc
| author affiliation = Entergy Nuclear South, Entergy Operations, Inc
| addressee name =  
| addressee name =  

Revision as of 07:13, 29 June 2019

Annual Report on Westinghouse Electric Company LLC Combustion Engineering Emergency Core Cooling System Performance Evaluation Models
ML113420045
Person / Time
Site: Waterford Entergy icon.png
Issue date: 12/07/2011
From: Steelman W
Entergy Nuclear South, Entergy Operations
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
W3F1-2011-0085
Download: ML113420045 (2)


Text

W3F1-2011-0085 December 7, 2011 U.S. Nuclear Regulatory Commission Attn: Document Control Desk

Washington, DC 20555-0001

Subject:

Annual Report on Westinghouse Electric Co mpany LLC Combustion Engineering Emergency Core Cooling System Performance Evaluation Models Waterford Steam Electr ic Station Unit 3 Docket No. 50-382

License No. NPF-38

Dear Sir or Madam:

This letter provides the Waterford Steam Electric Station Unit 3 (Waterford 3) 10CFR50.46(a)(3)(ii) reporting information per taining to the Westinghouse Electric Company Emergency Core Cooling System (ECCS) performance Evaluation Models (EMs) for calendar year 2010.

There were no changes, error corrections, or enhancements to the 1999 Evaluation Model (EM) which is used in the Large Break Loss-of-Coolant Accident (LBLOCA)

ECCS performance analysis. In addition, there were no c hanges, error corrections, or enhancements to the Supplement 2 Evaluation Model (S2M) which is the EM used in the Small Break Loss-of-Coolant Accident (SBLOCA) ECCS performance analysis.

This letter contains no new commitments.

If you have any questions or require additional information, please contact William Steelman at 504-739-6685.

Sincerely, WJS/ssf Entergy Nuclear South Entergy Operations, Inc.

17265 River Road Killona, LA 70057-3093 Tel 504 739 6685 Fax 504 739 6698 wsteelm@entergy.com William J. SteelmanLicensing Manager Waterford 3 W3F1-2010-0085 Page 2 cc: Mr. Elmo E. Collins, Jr.

Regional Administrator U. S. Nuclear Regulatory Commission Region IV

612 E. Lamar Blvd., Suite 400 Arlington, TX 76011-4125

RidsRgn4MailCenter@nrc.govNRC Senior Resident Inspector Waterford Steam Electric Station Unit 3 P.O. Box 822 Killona, LA 70066-0751 Marlone.Davis@nrc.govDean.Overland@nrc.govU. S. Nuclear Regulatory Commission Attn: Mr. N. Kalyanam Mail Stop O-07D1 Washington, DC 20555-0001 Kaly.Kalyanam@nrc.gov