ML16187A122: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
Line 3: Line 3:
| issue date = 07/01/2016
| issue date = 07/01/2016
| title = Notification of Inspection and Request for Information
| title = Notification of Inspection and Request for Information
| author name = Walker S A
| author name = Walker S
| author affiliation = NRC/RGN-II/DRS/EB3
| author affiliation = NRC/RGN-II/DRS/EB3
| addressee name = Vineyard D R
| addressee name = Vineyard D
| addressee affiliation = Southern Nuclear Operating Co, Inc
| addressee affiliation = Southern Nuclear Operating Co, Inc
| docket = 05000321, 05000366
| docket = 05000321, 05000366

Revision as of 01:05, 20 June 2019

Notification of Inspection and Request for Information
ML16187A122
Person / Time
Site: Hatch  Southern Nuclear icon.png
Issue date: 07/01/2016
From: Sandra Walker
NRC/RGN-II/DRS/EB3
To: Vineyard D
Southern Nuclear Operating Co
References
Download: ML16187A122 (6)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION REGION II 245 PEACHTREE CENTER AVENUE NE, SUITE 1200 ATLANTA, GEORGIA 30303-1257 July 1, 2016 Mr. David R. Vineyard Vice President

Southern Nuclear Operating Company, Inc.

Edwin I. Hatch Nuclear Plant 11028 Hatch Parkway North Baxley, GA 31513

SUBJECT:

EDWIN I. HATCH NUCLEAR PLANT - NOTIFICATION OF INSPECTION AND REQUEST FOR INFORMATION

Dear Mr. Vineyard:

The NRC will perform the baseline heat sink (HS) inspection at the Edwin I. Hatch Nuclear Plant from August 15 - 19, 2016. Experience has shown that this inspection is resource intensive both for the NRC inspectors and your staff. In order to minimize the impact to your onsite resources and to ensure a productive inspection, we have enclosed a request for documents needed for this inspection. These documents have been divided into two groups. Section A of the enclosure identifies information to be provided prior to the inspection to ensure that the inspectors are adequately prepared. Section B of the enclosure identifies the information the inspectors will need upon arrival at the site. It is important that all of these documents are up-to-date and complete in order to minimize the number of additional documents requested during the preparation and/or the onsite portions of the inspection.

We discussed the schedule for these inspection activities with your staff and understand that our regulatory contact for this inspection will be Jimmy Collins of your organization. Our inspection dates are subject to change based on your updated schedule of activities. If there are any questions about this inspection or the material requested, please contact the lead inspector, Brendan Collins, at (404) 997-4420 (Brendan.Collins@nrc.gov ). In accordance with Title 10 of the Code of Federal Regulations 2.390, "Public Inspections, Exemptions, Requests for Withholding," of the NRC's "Agency Rules of Practice and Procedure," a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS)

D. Vineyard 2 component of the NRC's Agencywide Document Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Sincerely,

/RA/ Shakur A. Walker, Chief Engineering Branch 3 Division of Reactor Safety

Docket Nos. 50-321, 50-366 License Nos. DPR-57, NPF-5

Enclosure:

Heat Sink Performance Document Request

cc: Distribution via Listserv

___ ________ SUNSI REVIEW COMPLETE FORM 665 ATTACHED OFFICE RII:DRS RII:DRS SIGNATURE BCC2 SAW4 NAME BCollins SWalker DATE 6/30/2016 7/1 /2016 7/ /2016 7/ /2016 7/ /2016 7/ /2016 E-MAIL COPY? YES NO YES NO YES NO YES NO YES NO YES NO Enclosure HEAT SINK PERFORMANCE DOCUMENT REQUEST Site: Edwin I. Hatch Nuclear Plant Docket Nos.: 50-321, 50-366

Inspection Dates: August 15 - 19, 2016

Entrance Meeting: August 15, 2016 Inspection Procedures: IP 71111.07, "Heat Sink Performance," dated 07/06/2010

Inspectors: Brendan Collins, Reactor Inspector A. Information Requested for the In-Office Preparation Week Please provide the information requested in this section to the NRC Region II Office in care of the lead inspector by July 29, 2016, in order to facilitate the selection of specific items that will be reviewed during the onsite inspection week. The information can be provided in hard copy or electronic format; however, electronic format is preferred, either by digital data storage device (e.g. com pact disk), or web-based document management system. If you have any questions regarding this information request, please call the lead inspector as soon as possible.

A.1 Heat Exchangers and Service Water Equipment a) List of heat exchangers (HXs) or equipment cooled by service water (SW) directly or indirectly

  • Include the risk ranking from the site specific risk assessment for each listed HX
  • Detail whether any cleaning or inspection activities are planned during the proposed onsite inspection period for any of the listed HXs
  • For HXs directly cooled by SW, provide the testing, inspection, maintenance, and monitoring of biotic fouling and macrofouling program documents b) Detail the HX performance inspection methods for HXs that are inspected/cleaned c) Response to Generic Letter 89-13 including any regulatory commitments made d) Design Basis documents associated with the SW system e) Design Basis documents associated with the Ultimate Heat Sink (UHS)

f) SW system flow diagrams

g) Recent Health Reports associated with the SW System and systems that are cooled by SW

2 h) List of SW system related corrective action documents (with a brief description) which have received a Root Cause Analysis or an elevated severity level in the last

three years i) Recent Operating Experience Events (2013-2016) j) List of applicable Codes and Industry Guidelines k) List of findings in the heat sink/heat exchanger performance area for the last 3 years l) List of redundant or infrequently used HXs

m) Chemistry Program for safety-related HXs.

n) Detail whether the UHS is above ground encapsulated by embankments, weirs or excavated side slopes; underwater weir or excavation; or forced draft cooling tower

or spray pond

o) Provide a list of buried or inaccessible piping and the piping test program, inspection or monitoring program

p) List of safety-related and non-safety related valve interfaces B. Information to be provided on-site to the inspector at the entrance meeting (August 15, 2016):

B.1 Heat Exchangers and Service Water Equipment The inspector will select two to four heat exchangers and/or heat sink samples as required by the inspection procedure during the in-office preparation. The following items will be requested when the selections are made:

a) Updated list of System Engineers

b) List of any thru-wall leaks including completed or planned corrective actions and structural evaluations c) Provide a copy of the corrective actions and supporting documentation d) For the HXs that have Visual and/or Eddy Current Testing performed, provide a copy of the examination records, examiner qualification records, and associated corrective action documents e) Heat transfer calculations f) Evaluations for the potential of water hammer g) Documentation for controls and operational limits for excessive flow induced vibrations h) Periodic flow test results at/or near maximum design flow

3 i) For an UHS that is encapsulated by embankments, weirs of excavated side slopes provide: (1) third party dam inspection results, and (2) documentation showing that there is sufficient reservoir capacity j) For an UHS that is an underwater weir or excavation provide documentation showing:

  • Periodic monitoring and trending of sediment build-up
  • Sufficient reservoir capacity
  • Considerations for adjacent non-seismic and/or non-safety related structures of possible degradation or blocking of safety-related flow paths due to severe weather or seismic events
  • Performance monitoring of heat transfer capabilities
  • Performance monitoring of UHS structural integrity
  • SW flow balance test results Inspector Contact Information: Brendan Collins Reactor Inspector 404-997-4421 Brendan.Collins@nrc.gov Mailing Address: US NRC Region 2 Attn: Paula Cooper Marquis One Tower 245 Peachtree Center Avenue, NE Suite 1200 Atlanta, GA 30303