- 05000400/LER-1987-048, :on 870811,failure to Take 9:30 Am Reading of Axial Flux Difference (Afd) as Required by Tech Specs Discovered.Caused by Personnel Error.Operator Disciplined. Addl Guidance Being Provided to Operators + (12:17:33, 7 January 2025)
- ML18004B935 + (12:17:34, 7 January 2025)
- IR 05000400/1987020 + (12:17:35, 7 January 2025)
- ML18004B933 + (12:17:37, 7 January 2025)
- ML18004B932 + (12:17:39, 7 January 2025)
- ML18004B930 + (12:17:40, 7 January 2025)
- IR 05000400/1987032 + (12:17:44, 7 January 2025)
- ML18004B927 + (12:17:46, 7 January 2025)
- 05000400/LER-1987-047, :on 870804-05,auxiliary Feedwater Actuations Occurred Due to Trips of Main Feedwater Pump 1A.Caused by Discharge Pressure Switches Out of Calibr.Discharge Pressure Switches Recalibr + (12:17:47, 7 January 2025)
- 05000400/LER-1987-041, :on 870804,restoration Alignment on Clearance for Placing Dryer 1B Back Into Svc Incorrect.Caused by Personnel Error.Valve Lineup for Instrument Air Dryer 1B Put Into Correct Configuration + (12:17:49, 7 January 2025)
- ML18004B923 + (12:17:50, 7 January 2025)
- ML18004B921 + (12:17:51, 7 January 2025)
- ML18004B922 + (12:17:51, 7 January 2025)
- ML18004B920 + (12:17:52, 7 January 2025)
- IR 05000400/1987025 + (12:17:59, 7 January 2025)
- ML18004B916 + (12:18:00, 7 January 2025)
- ML18004B915 + (12:18:01, 7 January 2025)
- ML18004B914 + (12:18:02, 7 January 2025)
- 05000400/LER-1987-046, :on 870722,main Feedwater Pump B Tripped Due to Low Flow Resulting in Automatic Start of Auxiliary Feedwater Pumps.Caused by Loose Linkage on Recirculation Valve Due to Vibration.Valve Repaired.Procedures Changed + (12:18:05, 7 January 2025)
- ML18004B911 + (12:18:07, 7 January 2025)
- IR 05000400/1987030 + (12:18:19, 7 January 2025)
- ML18004B908 + (12:18:20, 7 January 2025)
- ML18004B907 + (12:18:21, 7 January 2025)
- ML18004B906 + (12:18:22, 7 January 2025)
- ML18004B905 + (12:18:23, 7 January 2025)
- ML18004B904 + (12:18:24, 7 January 2025)
- 05000400/LER-1987-045, :on 870716,RCS Pressure Fell Below Accumulator Pressure,Initiating Partial Injection of All Three Accumulators.Caused by Reactor Operator Error.Operating Shift Disciplined & Procedure Revised + (12:18:26, 7 January 2025)
- 05000400/LER-1987-040, :on 870630,discovered That Surveillance Interval for Calorimetric Exceeded.Caused by Personnel Error.Night Order Issued Instructing Personnel on Importance of Performing Surveillances + (12:18:28, 7 January 2025)
- ML18004B898 + (12:18:29, 7 January 2025)
- ML18004B897 + (12:18:30, 7 January 2025)
- ML18004B896 + (12:18:31, 7 January 2025)
- ML18004B895 + (12:18:33, 7 January 2025)
- ML18004B894 + (12:18:34, 7 January 2025)
- ML18004B891 + (12:18:35, 7 January 2025)
- ML18004B890 + (12:18:36, 7 January 2025)
- 05000400/LER-1987-011, :on 870307,breaker Tripped Open Causing de-energization of Auxiliary Bus 1E.Caused by Procedural Inadequacy.Defective PIC Card in Power Supply to LT-112 Relay Replaced & Procedure Revised + (12:18:38, 7 January 2025)
- 05000400/LER-1987-038, :on 870622,high Steam Generator Water Level Turbine Trip & Main Feedwater Isolation Actuated Automatic Reactor Trip on Interlock.Caused by Sudden Increase in Electrical Load.Precautionary Measures Taken + (12:18:40, 7 January 2025)
- 05000400/LER-1987-039, :on 870619,intermediate Range (IR) High Neutron Flux Trip Setpoint Found Out of Calibr.Caused by Previous Adjustment to IR Setpoints.New Scaling Currents for 25% Trip Incorporated Into Applicable Procedures + (12:18:42, 7 January 2025)
- 05000400/LER-1987-037, :on 870621,manual Reactor Trip Initiated from 30% Power After Operating Main Feedwater Train Tripped. Caused by Failed Open Feedwater Pump Recirculation Valve. Circuit Repaired & Plant Returned to Svc + (12:18:43, 7 January 2025)
- 05000400/LER-1987-036, :on 870621,air Roll of 1A-SA Diesel Engine Not Performed within 4 to 8 H After Engine Shutdown.Caused by Marking in Test Procedure Step as Not Applicable.Engine Air Rolled.No Accumulation of Water Detected + (12:18:45, 7 January 2025)
- ML18004B880 + (12:18:46, 7 January 2025)
- 05000400/LER-1987-034, :on 870611,air Leakage by Inner & Outer Doors of Personnel Air Lock Excessive.Caused by Flat Spots on O-ring Seal.Seals on Inner & Outer Doors Replaced & Procedure OMM-001 Revised + (12:18:48, 7 January 2025)
- 05000400/LER-1987-035, :on 870617,reactor Coolant Pump C Tripped, Resulting in Reactor Trip Due to Low Flow in Reactor Coolant Loop C.Caused by Physical Contact W/Bus Encl.Program to Check & Drain Steam Supply Lines Initiated + (12:18:49, 7 January 2025)
- ML18004B876 + (12:18:52, 7 January 2025)
- ML18004B874 + (12:18:53, 7 January 2025)
- 05000400/LER-1987-033, :on 870607,experienced Trouble W/Engine Barring Device Not Rotating Engine as Required Using Plant Svc Air. Caused by Low Plant Svc Air Pressure.Mod Installed Attaching Engine Barring Device to Starting Air Tank Air + (12:18:54, 7 January 2025)
- ML18004B872 + (12:18:55, 7 January 2025)