This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML18139B106 + (02:13:24, 6 January 2025)
- ML18139B103 + (02:13:26, 6 January 2025)
- ML18139B102 + (02:13:26, 6 January 2025)
- ML18139B100 + (02:13:27, 6 January 2025)
- ML18139B099 + (02:13:28, 6 January 2025)
- ML18139B097 + (02:13:29, 6 January 2025)
- 05000281/LER-1981-016-03, /03L-0:on 810119,at 100% Power,Positive Pressure Greater than 0.05 Inches Water Could Not Be Maintained in Control Room.Caused by Deteriorated Seals on Door to Control Room Complex.Defective Doors Repaired + (02:13:31, 6 January 2025)
- 05000281/LER-1981-016, Forwards LER 81-016/03L-0 + (02:13:33, 6 January 2025)
- ML18139B093 + (02:13:34, 6 January 2025)
- ML18139B091 + (02:13:35, 6 January 2025)
- 05000280/LER-1981-003-03, /03L-0:on 810129,radiation Alarm Setpoint for Component Cooling Sys Found Greater than Twice Background. Caused by Decrease in Background Radiation Levels.Activity Levels Verified within Allowable Limits + (02:13:36, 6 January 2025)
- 05000280/LER-1981-002-03, /03L-0:on 810122,radiation Alarm Setpoint for Component Cooling Sys Found Greater than Twice Background. Caused by Reduced Background Due to Shutdown & Defueled Conditions.Activity Levels Verified within Allowable Limits + (02:13:38, 6 January 2025)
- ML18139B087 + (02:13:39, 6 January 2025)
- ML18139B086 + (02:13:40, 6 January 2025)
- IR 05000280/1980037 + (02:13:43, 6 January 2025)
- ML18139B083 + (02:13:44, 6 January 2025)
- ML18139B082 + (02:13:46, 6 January 2025)
- ML18139B080 + (02:13:46, 6 January 2025)
- 05000281/LER-1981-007-03, /03L-0:on 810114,at 100% power,PT-27 (Heat Tracing) Revealed Amp Readings for Panels 8 & 9 Circuits Were Below Acceptance Criteria.Caused by Excessive Temps Breaking Down Insulation.Defective Heat Tracing Replaced + (02:13:48, 6 January 2025)
- 05000281/LER-1981-006-03, /03L-0:on 810114,at Full Power,C Safety Injection Accumulator Found to Have Boron Concentration of 1943 Ppm, 7 Ppm Below Required Limit.Caused by Leakage Through Check Valve 1-SI-144.Valve Isolated + (02:13:50, 6 January 2025)
- ML18139B073 + (02:13:51, 6 January 2025)
- 05000281/LER-1981-013-03, /03L-0:on 810119,improperly Sealed Fire Barrier Penetration Discovered.Caused by Improper Matl Being Packed Into Penetration.Penetration Properly Sealed + (02:13:53, 6 January 2025)
- 05000281/LER-1981-011-03, /03L-0:on 810119,fire Watch Not Maintained While Fuel Oil Pumphouse Carbon Dioxide Sys Out of Svc for Design Change Mods.Caused by Personnel Leaving Post.Fire Watch re-established & Personnel Disciplined + (02:13:55, 6 January 2025)
- ML18139B066 + (02:13:56, 6 January 2025)
- 05000281/LER-1981-012-03, /03L-0:on 810118,boric Acid Transfer Pump 1-CH-P-2D Failed.Caused by Bearing Failure Due to Oil Seal Failure.Pump Repaired + (02:13:57, 6 January 2025)
- 05000281/LER-1981-012, Forwards LER 81-012/03L-0 + (02:13:59, 6 January 2025)
- ML18139B061 + (02:14:01, 6 January 2025)
- ML18139B062 + (02:14:01, 6 January 2025)
- ML18139B060 + (02:14:03, 6 January 2025)
- IR 05000280/1980040 + (02:14:04, 6 January 2025)
- ML18139B057 + (02:14:06, 6 January 2025)
- IR 05000280/1980041 + (02:14:07, 6 January 2025)
- ML18139B054 + (02:14:09, 6 January 2025)
- 05000281/LER-1981-009-03, /03L-0:on 810105,PT-27A Revealed Loss of Heat Tracing for Panel 11 Circuit 4C.Caused by Short in Heat Tape.Defective Heat Tracing Replaced.Design Change Initiated + (02:14:10, 6 January 2025)
- 05000281/LER-1981-004-03, /03L-0:on 810107,reactor Trip Breaker a Failed to Open.Caused by Sporadic Failure of Under Voltage Device Due to Missing Bushing.Under Voltage Device Replaced + (02:14:12, 6 January 2025)
- 05000281/LER-1981-003-03, /03L-0:on 810106,liquid Radwaste Monitors RM-GW-101,102,RM-VG-103,104,RM-SW-107 & RM-LW-108 Failed Low.Caused by Failed Fuse.Fuse Replaced + (02:14:14, 6 January 2025)
- 05000281/LER-1981-002-03, /03L-0:on 810105,PT-27A Revealed Loss of Heat Tracing for Panel 10 Circuits 1A & 1B & Panel 11 Circuit 4A. Caused by Open Heating Elements.Defective Heat Tracing Tape Replaced + (02:14:16, 6 January 2025)
- 05000281/LER-1981-001-03, /03L-0:on 810102,one Boric Acid Flow Path to Core Inoperable.Caused by Personnel Inadvertently Closing Valve 2-CH-226.Flow Path Restored & Personnel Reinstructed + (02:14:18, 6 January 2025)
- ML18139B047 + (02:14:19, 6 January 2025)
- IR 05000280/1980034 + (02:14:21, 6 January 2025)
- ML18139B045 + (02:14:22, 6 January 2025)
- ML18139B044 + (02:14:23, 6 January 2025)
- ML18139B043 + (02:14:24, 6 January 2025)
- ML18139B042 + (02:14:25, 6 January 2025)
- ML18139B040 + (02:14:26, 6 January 2025)
- ML18139B039 + (02:14:27, 6 January 2025)
- ML18139B038 + (02:14:28, 6 January 2025)
- ML18139B037 + (02:14:29, 6 January 2025)
- 05000281/LER-1980-049-03, /03L-0:on 801231,electrical Penetration E-4 Through Fire Wall Between Equipment Rooms 2 & 3 Turbine Basement Found Open.Caused by Fire Stop Removed to Accomodate Welding Lead.Fire Stop Repaired + (02:14:30, 6 January 2025)
- 05000281/LER-1980-049, Forwards LER 80-049/03L-0 + (02:14:32, 6 January 2025)
- ML18139B033 + (02:14:33, 6 January 2025)