- ML19350E727 + (00:05:06, 24 December 2024)
- 05000338/LER-1981-043-03, /03L-0:on 810523,steam Generator C Feedwater Flow Channel IV Dropped to 85% of Previously Indicated Value. Caused by Instrument Drift in Square Root Extractor Card. Channel Placed in Trip,Card Recalibr & Tested + (00:05:08, 24 December 2024)
- ML19350E725 + (00:05:12, 24 December 2024)
- ML19350E722 + (00:05:13, 24 December 2024)
- ML19350E721 + (00:05:14, 24 December 2024)
- 05000338/LER-1981-043, Forwards LER 81-043/03L-0 + (00:05:15, 24 December 2024)
- ML19350E718 + (00:05:16, 24 December 2024)
- ML19350E717 + (00:05:17, 24 December 2024)
- ML19350E715 + (00:05:18, 24 December 2024)
- ML19350E713 + (00:05:19, 24 December 2024)
- ML19350E712 + (00:05:20, 24 December 2024)
- ML19350E711 + (00:05:22, 24 December 2024)
- ML19350E710 + (00:05:24, 24 December 2024)
- ML19350E709 + (00:05:26, 24 December 2024)
- ML19350E707 + (00:05:27, 24 December 2024)
- ML19350E706 + (00:05:28, 24 December 2024)
- ML19350E704 + (00:05:29, 24 December 2024)
- ML19350E703 + (00:05:30, 24 December 2024)
- ML19350E702 + (00:05:31, 24 December 2024)
- IR 05000327/1981016 + (00:05:34, 24 December 2024)
- ML19350E699 + (00:05:36, 24 December 2024)
- ML19350E698 + (00:05:37, 24 December 2024)
- ML19350E697 + (00:05:38, 24 December 2024)
- ML19350E695 + (00:05:39, 24 December 2024)
- ML19350E696 + (00:05:39, 24 December 2024)
- ML19350E693 + (00:05:40, 24 December 2024)
- ML19350E692 + (00:05:41, 24 December 2024)
- ML19350E689 + (00:05:42, 24 December 2024)
- ML19350E686 + (00:05:43, 24 December 2024)
- ML19350E688 + (00:05:43, 24 December 2024)
- ML19350E684 + (00:05:44, 24 December 2024)
- 05000247/LER-1981-014-03, /03L-0:on 810517,one Sensing Device Found Not Operating on Level Transmitters LT-940 & LT-941.Caused by Foreign Matl Buildup on Instrument Stalks of Gem Level Transmitters.Matl Removed & Transmitter Tested + (00:05:46, 24 December 2024)
- 05000327/LER-1980-209-03, /03L-0:on 800922,no post-maint Testing Performed After Maint on RHR Heat Exchanger Discharge Isolation Valve. Caused by Personnel Error.List Issued Listing All Valves Which Require pre- or post-maint Testing + (00:05:48, 24 December 2024)
- 05000247/LER-1981-014, Forwards LER 81-014/03L-0 + (00:05:50, 24 December 2024)
- 05000327/LER-1980-209, Forwards LER 80-209/03L-0 + (00:05:55, 24 December 2024)
- IR 05000508/1981009 + (00:05:58, 24 December 2024)
- IR 05000416/1981015 + (00:06:00, 24 December 2024)
- ML19350E674 + (00:06:01, 24 December 2024)
- ML19350E672 + (00:06:02, 24 December 2024)
- PNO-I-81-066, on 810617,boron Recovery Degasifier Relief Valve Lifted Causing Higher than Normal Radioactive Gas Concentrations in Primary Auxiliary Bldg.Temporary Flowpath for RCS Drains Established + (00:06:08, 24 December 2024)
- ML19350E658 + (00:06:09, 24 December 2024)
- ML19350E662 + (00:06:09, 24 December 2024)
- ML19350E655 + (00:06:10, 24 December 2024)
- ML19350E654 + (00:06:15, 24 December 2024)
- ML19350E653 + (00:06:17, 24 December 2024)
- ML19350E651 + (00:06:18, 24 December 2024)
- ML19350E648 + (00:06:20, 24 December 2024)
- ML19350E649 + (00:06:20, 24 December 2024)
- ML19350E647 + (00:06:21, 24 December 2024)
- ML19350E646 + (00:06:22, 24 December 2024)
- ML19350E645 + (00:06:23, 24 December 2024)