Notice of Violation from Safety Insp on 810601.Noncompliance Noted:Wipe Tests of External Surface of Final Source Container Not Performed Since License Issuance
ML19350E696
Person / Time
Issue date: 06/16/1981
From: Wiedeman D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML19350E694 List:
References
NUDOCS 8106230449
Download: ML19350E696 (2)


Text

_

Appendix A NOTICE OF VIOLATION Jefferson Memorial Hospital License No. 24-18315-01 As a result of the inspection conducted on June 1,1981, and in accordance with the Interim Enforcement Policy, 45 FR 66754 (October 7,1980), the following violations were identified:

1.

License Condition No. 14 requires that licensed material be possessed and used in accordance with statements, representations, and procedures contained in application dated October 3, 1978.

License application dated October 3,1978, states that the procedures described in Appendix F of the NRC draft licensing guide dated November 1, 1977, shall be followed for opening packages containing radioactive materials. Appendix F states that wipe tests of the external surface of the final source container shall be performed and recorded.

Contrary to this requirement, it was learned through statements of licensee representatives that wipe tests of the external surface of the final source container were not performed since the date of license issuance.

This is a Severity Level V violation (Supplement VII).

2.

License Condition No. 14 requires that licensed material be possessed and used in accordance with stecements, representations, and procedures contained in application dated October 3, 1978.

License application dated October 3, 1978, states that the procedures described in Appendix I of the NRC draft licensing guide dated November 1, 1977, shall be followed for performing area surveys. Appendix I states that G-M surveys and wipe tests shall be performed and recorded.

Contrary to this requirement, it was learned through statements of licensee representatives that records of the G-M survey results were not maintained for the generator storage area. Wipe tests of the generator storage area were not performed since February 11, 1981.

This is a Severity Level V violation (Supplement VII).

3.

10 CFR 20.401(b) requires that you maintain records showing the results of surveys that you made to assure compliance with 10 CFR 20.201(b),

" Surveys."

8t10623O M

e

~

Appendix A '

Contrary to this requirement, you failed to maintain records of survey results to ensure compliance with 20.105, a regulation which limits the levels of radiation in unrestricted areas.

Specifically, you failed to keep a record of the survey results for a storage area which was released for unrestricted use.

This is a Severity Level VI violation (Supplement IV).

Pursuant to the provisions of 10 CFR 2.201, you are required to submit to this office within thirty days of the date of this Notice a written statement or explanation in reply, including for each item of noncompliaace:

(1) cor-rective action taken and the results achieved; (2) corrective action to be taken to avoid further noncompliance; and (3) the date when full compliance wi 1 be achieved. Under the authority of Section 182 of the Atomic Energy Act of 1954, as amended, this response shall be submitted under oath or affirmation. Consideration may be given to extending your response time for good cause shown.

/ //

Da ted ' /

D. G.' Wiedeman, Acting Chief Materials Radiation Protection Section 1

. -.