- 05000281/LER-1982-075-01, /01T-0:on 821219,while Conducting RCS Integrity Test,Weld Leak on Steam Generator a Channel Head Drain Piping at 2-RC-159 Identified.Probably Caused by Poor Fusion Between Successive Passes in Weld.Defective Weld Repaired + (00:01:33, 21 December 2024)
- ML20028C274 + (00:01:35, 21 December 2024)
- ML20028C273 + (00:01:36, 21 December 2024)
- 05000324/LER-1982-139, Forwards LER 82-139/01T-0 + (00:01:37, 21 December 2024)
- 05000316/LER-1982-098-03, /03L-0:on 821127,fire Detection Sys Alarm for 4 Kv Switchgear Room Received Due to Pyralarm Detector Alarming. Caused by Low Alarm Setpoint.Pyralarm Replaced + (00:01:39, 21 December 2024)
- 05000281/LER-1982-075, Forwards LER 82-075/01T-0 + (00:01:41, 21 December 2024)
- ML20028C267 + (00:01:43, 21 December 2024)
- 05000316/LER-1982-097-03, /03L-0:on 821204,fire Detection Sys Alarm for 4 Kv Switchgear Room Received Due to Pyralarm Detector Alarming for No Apparent Reason.Caused by Low Setpoint.New Detector Installed + (00:01:44, 21 December 2024)
- PNO-III-83-001, on 821231,during Controlled Shutdown,Two ECCS Degraded Necessitating Declaration of Alert.Shutdown Started Due to Inoperable RHR Pump B.During Shutdown Automatic Depressurization Sys Lost Due to Low Air Pressure + (00:01:46, 21 December 2024)
- ML20028C264 + (00:01:47, 21 December 2024)
- ML20028C262 + (00:01:48, 21 December 2024)
- 05000325/LER-1982-126-03, /03L-0:on 821201,primary Containment Atmosphere Oxygen Analyzer 1-CAC-AT-1259-2 Indicated Unexpected Downward Trend in Drywell Oxygen Concentration.Caused by Instrument Zero Shift.Analyzer Recalibr & Returned to Svc + (00:01:49, 21 December 2024)
- NUREG/CR-2934, Forwards NUREG/CR-2934, Review & Evaluation of Indian Point Probabilistic Safety Study, Final Sandia Rept.W/O Encl + (00:01:51, 21 December 2024)
- ML20028C257 + (00:01:56, 21 December 2024)
- ML20028C258 + (00:01:56, 21 December 2024)
- 05000325/LER-1982-126, Forwards LER 82-126/03L-0 + (00:01:58, 21 December 2024)
- ML20028C252 + (00:02:01, 21 December 2024)
- ML20028C251 + (00:02:02, 21 December 2024)
- 05000324/LER-1982-133-03, /03L-0:on 821204 & 05,discovered Inoperable RTGB Position Indication for Control Rods 10-31,38-23 & 18-11. Caused by Defective IC Chip & Transistor on Probe Buffer Board of Rod 18-11 & Defective Reed Switch + (00:02:03, 21 December 2024)
- ML20028C248 + (00:02:07, 21 December 2024)
- 05000324/LER-1982-133, Forwards LER 82-133/03L-0 + (00:02:08, 21 December 2024)
- IR 05000255/1982025 + (00:02:10, 21 December 2024)
- 05000306/LER-1982-025-03, /03L-0:on 821130,one Steam Flow Channel Differed from Redundant Channels During Power Reduction Due to out- of-calibr Transmitter.Cause Not Known.Transmitter Recalibr & Returned to Svc.Transmitter to Be Replaced If Drift Rec + (00:02:12, 21 December 2024)
- 05000416/LER-1982-154-03, /03L-0:on 821204,shutdown Cooling Loop a of RHR Secured for Standby Svc Water Loop a Hydrostatic Test.Caused by Need to Perform Hydrostatic Test.Reactor Water Cleanup Used as Alternate DHR Method + (00:02:14, 21 December 2024)
- ML20028C241 + (00:02:16, 21 December 2024)
- ML20028C236 + (00:02:18, 21 December 2024)
- 05000295/LER-1982-046-03, /03L-0:on 821203,while Disassembling Discharge Valve,Crosstie Valve Between Boric Acid Transfer Pumps 1A & 1B Found Leaking.Caused by Valve Normal End of Life.Repairs Completed & Pump 1A Returned to Svc + (00:02:20, 21 December 2024)
- AECM-82-644, Rsps:On 821229,unidentified Caller Telephoned Threat Re Bomb in Bathroom of Administration Bldg.No Bomb Found.Call Considered Hoax + (00:02:21, 21 December 2024)
- 05000416/LER-1982-154, Forwards LER 82-154/03L-0 + (00:02:23, 21 December 2024)
- PNO-V-82-051, on 821229,liquid Radwaste Monitor Found Inoperable.Caused by Flow Director Kerotest Valve Being Installed Backwards.Valve Cutout,Reversed & Reinstalled in Proper Direction + (00:02:26, 21 December 2024)
- 05000325/LER-1982-121-03, /03L-0:on 821130,RTGB Control switch,1-VA-CS-2581 for Standby Gas Treatment Sys 1B Was in Standby,Not Preferred Position.Caused by Failed Spring Return Function. Switch Repaired,Cleaned & Restored to Svc + (00:02:27, 21 December 2024)
- 05000295/LER-1982-046, Forwards LER 82-046/03L-0 + (00:02:29, 21 December 2024)
- 05000237/LER-1982-049-03, /03L-0:on 821128,during Quarterly Valve Timing Surveillance DOS 1600-1,torus Inert & Purge Valve 2-1601-56 Would Not auto-close.Caused by Versa Valve Leaking from Weep Hole Due to Hardening of O-ring Seal.Valve Replaced + (00:02:31, 21 December 2024)
- IR 05000344/1982034 + (00:02:33, 21 December 2024)
- ML20028C225 + (00:02:34, 21 December 2024)
- ML20028C224 + (00:02:35, 21 December 2024)
- 05000325/LER-1982-121, Forwards LER 82-121/03L-0 + (00:02:36, 21 December 2024)
- ML20028C220 + (00:02:37, 21 December 2024)
- ML20028C219 + (00:02:38, 21 December 2024)
- ML20028C218 + (00:02:39, 21 December 2024)
- 05000325/LER-1982-134-03, /03L-0:on 821201,primary Containment Atmosphere Oxygen analyzer,1-CAC-AT-1263-2,indicated Step Increase in Drywell Oxygen Concentration.Caused by 1262-2 Analyzer Experiencing Instrument Zero Shift.Analyzer Recalibr + (00:02:40, 21 December 2024)
- PNO-II-83-001, on 831224,logging Tool Broken Open to Remove Threaded,Scaled 125-mCi Cs-137 Source.Caused by Prof Logging Svcs Employee Action.Complete Decontamination & Proper Disposal of Contaminated Matl to Be Performed + (00:02:43, 21 December 2024)
- ML20028C215 + (00:02:43, 21 December 2024)
- IR 05000346/1982032 + (00:02:45, 21 December 2024)
- 05000325/LER-1982-145-03, /03L-0:on 821129,main Steam Safety Relief Valve (SRV) Position Indication Instrument 1-B21-TR-R614,points 2 & 4 Printed Intermittently on Chart Paper.Srv Sonic Detector Lights Inoperable.Caused by Timing Motor Gear Teeth Wea + (00:02:46, 21 December 2024)
- 05000325/LER-1982-134, Forwards LER 82-134/03L-0 + (00:02:48, 21 December 2024)
- 05000325/LER-1982-145, Forwards LER 82-145/03L-0 + (00:02:50, 21 December 2024)
- ML20028C208 + (00:02:51, 21 December 2024)
- ML20028C206 + (00:02:52, 21 December 2024)
- 05000373/LER-1982-160-03, /03L-0:on 821124,while Running at 450 Mwt,Leak Detected on High Point Vent Line for Discharge Line from Condensate Booster Pump 1B.Cause Undetermined.Line Repaired + (00:02:53, 21 December 2024)
- 05000373/LER-1982-168-03, /03L-0:on 821201,steam Leak Discovered on Pressure Sensing Line for RCIC Instruments DPIS 1E31-N0007B & Ps 1E31-N022B&D.Caused by Failure of Compression Fitting on Instrumentation Steam Pressure Line.Leak Repaired + (00:03:01, 21 December 2024)