Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000321/LER-1987-011, :on 870723,reactor Water Level Decreased to Reactor Protection Sys Actuation Setpoint & Reactor Scram Occurred.Caused by Equipment Failure Due to Inadequate Ventilation Design.Inverter Refurbished + (01:08:50, 2 December 2024)
- ML20247K285 + (01:08:51, 2 December 2024)
- ML20247K281 + (01:08:52, 2 December 2024)
- ML20247K283 + (01:08:52, 2 December 2024)
- A07780, Comments on NRC 890123 SER Approving Inservice Insp Program, Third 10-yr Interval,Rev 1.Util Will Upgrade Classification of Svc Water Supply & Return Lines to Containment Air Recirculation Fan Coolers to ASME Class 2 + (01:08:53, 2 December 2024)
- 05000368/LER-1989-010, :on 890425,discovered That Valve Stroke Surveillance Test for LPSI Sys & Refueling Water Tank Had Not Been Performed.Caused by Personnel Incorrectly Indicating Tests as Already Performed + (01:08:55, 2 December 2024)
- ML20247K277 + (01:08:56, 2 December 2024)
- ML20247K275 + (01:08:56, 2 December 2024)
- NRC-89-0177, Advises That Listed Actions Re Locked Valve Program at Plant Meets Requirements of TMI Action Plan,Item II.K.1.5, NUREG-0737,per 881114 Commitment.Design Calculation for Locked Valve Program Issued 890131 + (01:08:57, 2 December 2024)
- ML20247K274 + (01:08:57, 2 December 2024)
- ML20247K269 + (01:08:59, 2 December 2024)
- IR 05000483/1998005 + (01:09:01, 2 December 2024)
- ML20247K266 + (01:09:01, 2 December 2024)
- ML20247K263 + (01:09:02, 2 December 2024)
- ML20247K264 + (01:09:02, 2 December 2024)
- ML20247K261 + (01:09:03, 2 December 2024)
- ML20247K260 + (01:09:04, 2 December 2024)
- 05000368/LER-1986-014, :on 860627,emergency Diesel Generator Failed. Caused by Engine Fuel Starvation Due to Severely Fouled Y- Strainer 2F-195B Screen Element.Mesh Screen Internals of Y-strainers Removed + (01:09:06, 2 December 2024)
- ML20247K257 + (01:09:07, 2 December 2024)
- ML20247K256 + (01:09:08, 2 December 2024)
- ML20247K254 + (01:09:08, 2 December 2024)
- ML20247K252 + (01:09:09, 2 December 2024)
- ML20247K253 + (01:09:09, 2 December 2024)
- ML20247K250 + (01:09:10, 2 December 2024)
- ML20247K249 + (01:09:11, 2 December 2024)
- ML20247K247 + (01:09:12, 2 December 2024)
- ML20247K246 + (01:09:13, 2 December 2024)
- ML20247K243 + (01:09:16, 2 December 2024)
- NG-98-0733, Informs That Util Plans to Continue Participating in Joint Owners Group (JOG) Program on MOV Periodical Verification Program,As NRC Accepts JOG Program as Acceptable Response to GL 96-05 + (01:09:16, 2 December 2024)
- ML20247K241 + (01:09:17, 2 December 2024)
- IR 05000361/1997022 + (01:09:21, 2 December 2024)
- ML20247K239 + (01:09:21, 2 December 2024)
- PY-CEI-NRR-0987, Submits Info Re Property Insurance Coverage for Units 1 & 2, Per 10CFR50.54(w)(4) + (01:09:22, 2 December 2024)
- ML20247K236 + (01:09:23, 2 December 2024)
- 05000373/LER-1989-008, :on 890228,reactor Vessel Low Water Level 2 Switch Found W/Setpoint Out of Tolerance in Excess of Reject Limit During Surveillance.Caused by Setpoint Drift.Work Request L87899 Written to Replace Instrument + (01:09:25, 2 December 2024)
- ML20247K231 + (01:09:26, 2 December 2024)
- ML20247K232 + (01:09:26, 2 December 2024)
- ML20247K229 + (01:09:27, 2 December 2024)
- 05000302/LER-1989-008-01, Forwards LER 89-008-01 & Proposed Draft FSAR Change. Reanalysis in LER Initiated to Evaluate Consequences of Operation W/Steam Drain Trap Isolation Valves Open for All Events.Revised FSAR Pages Will Be Incorporated in Rev 12 + (01:09:30, 2 December 2024)
- ML20247K223 + (01:09:31, 2 December 2024)
- IR 05000263/1998006 + (01:09:32, 2 December 2024)
- ML20247K222 + (01:09:32, 2 December 2024)
- 05000333/LER-1989-006-01, :on 890419,standby Liquid Control Sys Declared Inoperable When Pump Discharge Accumulator Nitrogen Precharge Was 0 Psig.Caused by Slow Leak in Charging Connector Spring Loaded Valve.Bladder Repaired + (01:09:34, 2 December 2024)
- 05000440/LER-1989-007, :on 890227,source-range Monitor Signal/Noise Ratio Not Verified Prior to Entering Operation Condition 5. Caused by Personnel Error.Personnel Counseled & Note Added to Tech Spec Rounds to Clarify Applicability Requirements + (01:09:37, 2 December 2024)
- ML20247K213 + (01:09:38, 2 December 2024)
- ML20247K214 + (01:09:38, 2 December 2024)
- 05000440/LER-1989-006, :on 890224,primary Containment Leakage Rate Through First MSIV Before Seat Drain Valves Exceeded Tech Spec Limit.Caused by Misalignment of Valve Disc.Seat Polishing & Machining of Poppet Seals Performed + (01:09:40, 2 December 2024)
- A98035, Monthly Operating Repts for Apr 1998 for Zion Station,Units 1 & 2 + (01:09:41, 2 December 2024)
- ML20247K208 + (01:09:42, 2 December 2024)
- ML20247K207 + (01:09:43, 2 December 2024)
- ML20247K204 + (01:09:45, 2 December 2024)