Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20062C596 + (05:04:56, 17 December 2024)
- 05000413/LER-1990-017-01, :on 900926,Tech Spec 3.0.3 Entered Due to Loss of Control Rod Position Indications + (05:04:58, 17 December 2024)
- ML20062C591 + (05:04:59, 17 December 2024)
- ML20062C592 + (05:04:59, 17 December 2024)
- A08863, Forwards Proprietary Info Re Matl Certifications for Facility Control Element Assembly Action Program + (05:05:00, 17 December 2024)
- ML20062C589 + (05:05:00, 17 December 2024)
- ML20062C587 + (05:05:01, 17 December 2024)
- IR 05000334/1982013 + (05:05:10, 17 December 2024)
- ML20062C583 + (05:05:10, 17 December 2024)
- ML20062C582 + (05:05:11, 17 December 2024)
- ML20062C580 + (05:05:11, 17 December 2024)
- IR 05000395/1978017 + (05:05:13, 17 December 2024)
- ML20062C578 + (05:05:13, 17 December 2024)
- ML20062C575 + (05:05:14, 17 December 2024)
- ML20062C574 + (05:05:14, 17 December 2024)
- ML20062C572 + (05:05:15, 17 December 2024)
- ML20062C571 + (05:05:16, 17 December 2024)
- ML20062C569 + (05:05:19, 17 December 2024)
- 05000259/LER-1982-046-03, /03L-0:on 820701-05,intermittent Trouble Alarms Received from Fire Protection Panel 1-25-311.Caused by Common Control Card Giving Intermittent Trouble Alarms. Circuit Board Replaced + (05:05:21, 17 December 2024)
- IR 05000259/1978018 + (05:05:22, 17 December 2024)
- 05000259/LER-1982-046, Forwards LER 82-046/03L-0 + (05:05:23, 17 December 2024)
- ML20062C561 + (05:05:23, 17 December 2024)
- ML20062C560 + (05:05:24, 17 December 2024)
- ML20062C558 + (05:05:24, 17 December 2024)
- ML20062C557 + (05:05:25, 17 December 2024)
- 05000320/LER-1982-020-01, /01L-0:on 820603,determined That Recent Overflow of Auxiliary Bldg Sump Occurred Due to Influx of Rainwater from Borated Water Storage Tank Recirculation Pump.Caused by Inadequate Flood Protection.Procedures Modified + (05:05:27, 17 December 2024)
- ML20062C553 + (05:05:28, 17 December 2024)
- 05000220/LER-1978-036-04, /04T-0 on 781025:improper Appl of Brook Model 9456 Oval Gear Flowmeter Combined W/Failed Seal on Caustic Addition Pump Caused High Concentration of Sodium & Sulfate & Degraded Capability to Control Rate of Discharge + (05:05:29, 17 December 2024)
- 05000219/LER-1982-040-01, /01T-0:on 820707,signal Input Disconnected to Safety Valve Vibration Monitor Rendering Acoustic Monitoring Channel Inoperable.Cause Undetermined.Wire Reconnected & Alarm Will Be Added to Alarm Circuit + (05:05:31, 17 December 2024)
- 05000440/LER-1990-027, :on 900925,personnel Error Resulted in Air Roll of Div 1 Diesel Generator + (05:05:33, 17 December 2024)
- 05000277/LER-1978-020-01, /01T-0 on 781019:unit 3 Containment Oxygen Concentration Had Increased to 0.1% Above 4 Percent Limit of Tech Spec 3.7.A.5.Caused by Open Air back-up Valves in Inoperable Instru Nitrogen Compressor + (05:05:35, 17 December 2024)
- ML20062C546 + (05:05:37, 17 December 2024)
- ST-HL-AE-3595, Responds to Generic Ltr 90-03, Relaxation of Staff Position in Generic Ltr 83-28,Item 2.2,Part 2, `Vendor Interface for Safety-Related Components + (05:05:40, 17 December 2024)
- 05000320/LER-1982-020, Forwards LER 82-020/01L-0 + (05:05:43, 17 December 2024)
- 05000277/LER-1978-020, Forwards LER 78-020/01T-0 + (05:05:45, 17 December 2024)
- ML20062C539 + (05:05:46, 17 December 2024)
- 05000277/LER-1978-041-01, /01T-0 on 781010:2 4KV Emergency Bus Sequential Loading Relays Found Outside Tech Spec Limits.Caused by Error in Determining Setpoint & Calibr Span of Relays.Relays Recalib & Testing Procedures Revised + (05:05:48, 17 December 2024)
- 05000293/LER-1982-021-03, /03L-0:on 820624,fire Door 153 on 37 Ft Elevation of Turbine Bldg Annex Found Blocked Opened.Caused by Door Being Blocked to Remove Matl.Faulty Lock Replaced + (05:05:50, 17 December 2024)
- ML20062C536 + (05:05:51, 17 December 2024)
- 05000219/LER-1982-040, Forwards LER 82-040/01T-0.Detailed Event Analysis Encl + (05:05:52, 17 December 2024)
- ML20062C526 + (05:05:54, 17 December 2024)
- ML20062C524 + (05:05:55, 17 December 2024)
- ML20062C525 + (05:05:55, 17 December 2024)
- ML20062C522 + (05:05:56, 17 December 2024)
- ML20062C523 + (05:05:56, 17 December 2024)
- IR 05000271/1982005 + (05:06:57, 17 December 2024)
- 05000456/LER-1990-018-02, :on 900929,spurious Train B Solid State Protection Sys Actuations Occurred Due to Component Failure + (05:06:59, 17 December 2024)
- ML20062C519 + (05:07:00, 17 December 2024)
- ML20062C518 + (05:07:00, 17 December 2024)
- ML20062C515 + (05:07:02, 17 December 2024)
- ML20062C517 + (05:07:02, 17 December 2024)